Product catalogue March 2011

Size: px
Start display at page:

Download "Product catalogue March 2011"

Transcription

1 Product catalogue March 2011

2 Fenix was founded in 1990 as one of the fi rst private companies in the Czech Republic following the Velvet Revolution. The fi rst items produced were the successfully marketed ECOSUN electric radiant heating panels, however, as market demand increased these products were followed by ECOFLEX electric convectors, ECOFLOOR heating cables and mats and ECOFILM heating fi lms. The company also offers a wide range of supplementary products including heating system controls, cable kits and cable mats. With the increase in demand the structure of the company developed for the reason of retaining maximum fl exibility a holding company structure was chosen, with individual and independent members. The following companies were incorporated successively: Fenix s.r.o. plant producing electrical heating systems; Fenix Trading s.r.o. trading company; Fenix Slovakia s.r.o. production and trading company, representing FENIX in Slovakia; Fenix Group a.s. a company which provides property management and services (strategic planning, administration of property, economic and fi nancial services); Flexel International Ltd. manufacturing and trading company located in the United Kingdom. In 2008 FENIX Holding acquired the production and trading company Aztec Europe Ltd., manufacturer of special applications, such as mirror demisting heaters, vivarium heaters, caravan and

3 ECOSUN radiant heating panels low and high temperature radiant ceiling panels pages 4 5 MR marble radiant panels for residential, commercial and individual application page 6 GR glass radiant panels for residential, commercial and individual application pages 7 8 IRC PANELS radiant heating for infrared cabins pages 9 10 ECOFLOOR heating cable systems heating cable circuits and cable mats, complete fl oor heating installation kits, deicing gutters and eaves troughs, snow-melting, de-icing outdoor surfaces, frost protection of pipes pages ECOFILM heating fi lm systems E-set underfl oor heating, kit for DIY installation F underfl oor heating fi lm C radiant ceiling heating fi lm, MHF mirror fogging prevention pages ULTRATHERM heating for vivariums and terrariums pages ECOFLEX electric convectors classic and glass convection heaters pages THERMOSTATS AND CONTROLS regulation unit, control unit, room and fl oor sensors, and regulators for reduction of main circuit breaker value pages STORAGE HEATERS static and dynamic storage heaters page 37 ATLANTIC storage water heaters L volume page 38 SUPPLEMENTARY PRODUCTS hand dryers, towel radiators page 38 mobile home heating equipment. At the end of 2009/in early 2010 Fenix Holding acquired two other production and trading companies: ACSO production and trading company with its headquarters in France; CEILHIT producer of heating cables and trading company with its headquarters in Spain, covering the market in Spain, Portugal and South America. Presently, the company Fenix Holding s.r.o. is one of the largest European producers of surface electric heating systems, and currently exports to over 52 countries worldwide.

4 ECOSUN radiant heating panels Principle of infrared heating Whereas in convection heating the air is warmed by a convector which then transfers heat as it fl ows over the objects that are to be heated (walls, furniture), Radiant heating panels transfer heat mainly through radiant energy. Upon encountering objects (walls, furniture, fl oors), radiant energy is partially refl ected (approx. 15 %), the majority (approx. 85 %) is absorbed by the objects. This radiant energy is converted to heating energy as it raises the temperature of the objects, which then transfer heat to the cooler air by convection. Thanks to unique technology Silicating, high temperature radiant panels reach high emissivity up to 0,98 mu. The principles mentioned create the following advantages: the surface of the radiant panel generates a heat fl ow whose spectrum is in the wavelength not greater than 5 micrometers and is thus absorbed to a large degree by the human body: people are therefore heated in a manner similar to the objects in the room. when the radiant heat fl ow increases the temperature of the objects in the room of C, comfort conditions are achieved even with air temperatures of C which can lead to energy savings of %. radiant panels permit the temperature distribution in a room to be more vertically balanced giving a 1 2 degree difference between the fl oor and the ceiling (for convection heating the difference is given as 1 C per metre of height, cm of height). there is less fl ow movement therefore dust particles due to brownian movement are less thus reducing the risk of illnesses asthma, mucous membrane infection, etc. increased wall temperatures mean a lower possibility of surface condensation, albeit the humidity in the room is not lowered. glass is not transparent (we might say transthermant ) when it comes to radiation with wavelengths over 3 and thus the radiant fl ow is not lost through windowpanes. the panels do not require maintenance Unique technologies Fenix utilises unique state-of-the art technology in respect of the fi nished panel surfaces. (Thermoquartz and Thermocrystal for low temperature panels and Silicating for high temperature panels). Radiant heating by ECOSUN Convection heating 4

5 LOW TEMPERATURE PANELS ECOSUN K+ heating panel used for warming church pews, desks in offi ces and administrative buildings. They can be hung on a wall in the standard way; for installation on the ceiling it is necessary to order a ceiling frame. Class I. Basic colour: brown (RAL 8017), white (RAL 9016) Connection cable: 50 cm for K+, 75 cm for K+ TYPE [V] Covering Dimmensions [mm] Weight [kg] Recommended clearance Quantity on pallet ECOSUN 100 K , ECOSUN 200 K , ECOSUN 270 K IP ,2 Mounted in ECOSUN 330 K , ECOSUN 400 K , Ceiling fi xing frame for ECOSUN 100 K+, 200 K+, 270 K+, 330 K+, 400 K+ ECOSUN U universal panel for dwelling and non-dwelling spaces, possibly mounted onto ceilings or into suspended ceilings. Class I. Basic colour: white (RAL 9016) Connection cable: 100 cm TYPE [V] Covering Dimmensions [mm] Weight [kg] Recommended clearance Quantity on pallet ECOSUN 300 U ,0 2,5 3, ECOSUN 600 U IP 44 10,1 2,8 3, ECOSUN 700 U ,5 3,0 3, ECOSUN C heating panels only for mounting into suspended ceilings. Class I. Basic colour: white (RAL 9016) TYPE [V] Covering Dimmensions [mm] Weight [kg] Recommended clearance Quantity on pallet ECOSUN 300 c 600/VT ,6 2,5 3, IP 20 ECOSUN 600 c 600/VT ,4 2,8 3, ECOSUN IKP, IN, IN-2 panels for industrial and agricultural applications (i.e. in workshops, greenhouses, livestock facilities). Basic colour: brown (RAL 8017) Connection cable: 100 cm TYPE [V] Covering Dimmensions [mm] Weight [kg] Recommended clearance Quantity on pallet ECOSUN 700 IKP 700 IP ,3 2,5 3, ECOSUN 700 IN IP 65 ECOSUN 700 IN Ceiling fi xing frame for type IKP, IN, IN-2 IP 65 E Ex ,5 2,8 3, ,0 3, HIGH TEMPERATURE PANELS ECOSUN S / SB for industrial halls, gyps, halls, workshops, wit coverage that corresponds to the given environment. Suitable for drying of buildings. Class I. Covering IP x4. Basic colour: white (RAL 9010). For spaces with higher humidity agricultural structures, washing facilities, panels are produced in a corrosion-proof version SBs stainless. TYPE S white S 09 Weight [kg] Quantity on pallet HALOGEN HEATERS Dimmensions [mm] TYPE SB stainless Weight [kg] Quantity on pallet Dimmensions [mm] [V] SB 09s , , S SB 12s S SB 18s , S SB 24s S SB 30s , , S SB 36s Halogen heaters the high surface temperature of halogen tubes enables the use of the radiators in areas where normal radiant panels wouldn t be effective for example, in outdoor areas for the heating of terraces and balconies, or for the heating of large industrial halls with no heat cladding. TYPE [V] Covering Dimmensions [mm] Weight [kg] Recommended clearance HWP IP ,7 2,2 3,0 m HN ,5 3,0 4,5 m IP 21 HN ,5 3,5 5,5 m / 400 2N 5

6 RADIANT PANELS MR marble radiant panels MR marble radiant panels are primarily intended for heating reception rooms, halls, bathrooms and others. MR panel has an extremely aesthetic appearance and the radiant heat from this natural material is very acceptable. The MR panel consists of a robust polished marble plate, a heating element, limiting thermostat, and a connection cable. This panel is intended to be installed as a fi xed installation on a wall with the connection cable connected to the installation box. These panels are manufactured in various power outputs and are available in 5 marble designs. As marble is a natural material there is the possibility of small colour and texture variances. MR PANELS marble radiant panels (thermo fuse), IP 44, class II; Connection cable for :100 cm, 1200: 150 cm; Type of marble: Kavala, Volakas, Janina, Rosa, Veria Green; Needed clearance: lower edge 5 cm / top and side edge 15 cm / front side 50 cm IP 44 TYPE Dimensions [mm] Weight [kg] Marble MR MR MR Volakas MR MR MR MR MR Kavala MR MR MR MR MR Janina MR MR MR MR MR Rosa MR MR MR MR MR Veria Green MR MR KAVALA VOLAKAS JANINA ROSA VERIA GREEN 6

7 GR glass radiant panels GR glass radiant panels feature an attractive and timeless design. Due to the aesthetic appearance these panels are primarily intended for heating reception rooms, offi ces and others. Glass panels consist of a 12 mm toughened glass plate heating element, thermo fuse, and connection cable. They are designed to be mounted on a wall connecting the connection cable to the wiring box. GR panels GR PANELS glass panels (thermo fuse), IP 44, class II; Connection cable: 100 cm; Panels are manufactured in 4 series with different outputs. GR panels you can choose from fi ve colours: mirror, white, black, red, yellow-green; Needed clearance: lower edge 5 cm / top and side edge 15 cm / front side 50 cm TYPE Output Dimensions [mm] Weight [kg] Quantity on pallet / in crate Glass colour GR / 22 pcs x GR / 12 pcs x white, black, red, yellow-green GR / 12 pcs x GR / 8 pcs x GR / 12 pcs mirror GR / 8 pcs GR SET panels with wireless regulation Use: These types are derived from standard GR panels but they are additionally fi tted with an integrated BPT-SP2 wireless receiver (see the chapter THERMOSTATS AND CONTROLS) and a supply lead fi tted with a plug. A wireless programmable thermostat is supplied with every panel as part of the package and so it is possible that, after unpacking the product, hanging it on the wall and connecting it to the socket, the panel can be operated immediately, without any assistance from a specialized installation company. The panels are intended mainly for supplementary installation, without the necessity of intervention into the existing electrical system. GR SET panels can be supplemented with chromium-coated supports (see page 8) and thus a very aesthetic and convenient portable heater can be created. Glass colours: white, black, yellow-green, red and mirror. IP 44 TYPE Output Dimensions [mm] Weight [kg] Glass colour GR Set , x GR Set 500 GR Set ,4 white, black, red, yellow-green x x GR Set x GR Set mirror GR Set

8 SUPPORTS FOR GR PANELS for applications where the GR panel cannot be hung on a wall (e.g. in the case of glass surfaces), a set of chromium plated supports can be used for the placement of the panels on the fl oor. STAINLESS STEEL TOWEL RAIL for GR/GR SET 300, 500, 700 and 900 panels These Towel rail designed as an accessory for GR and GR SET radiant glass panels in all colour versions. It is made from a 4 30 mm polished stainless steel sheet. After its installation, the standard panel is transformed into a smart bathroom heater with a rail on which a towel or bath towel can be hung. The GR panel is inserted into apertures in the supports and subsequently the supports are affi xed to the panels with the help of adjustment screws. The panel is stable on these supports; the bottom edge of the panel is 55 mm above the fl oor. For permanent installations, we recommend that the supports are attached to the fl oor using screws in the base there are two openings with a diameter of 6 mm for screws with countersunk heads. The supports are intended for use only with the GR type and are only for horizontal installation. In the case of vertical installation (particularly for GR 1000 panels), there is a signifi cantly higher risk that the user may accidentally knock the panel over. GR panels on supports must not be exposed to excessive pressure there is a danger of tipping if it is placed freely, and if the supports are attached to the fl oor, there is a risk of damage to the glass in the places where supports are attached. PRODUCT Supports for GR panels Contents of the set: chromium plated supports 2 pcs (base diameter 130 mm), plastic covers for the brackets for the GR panel 4 pcs, mains plug (to be installed on the supply lead if the panel is to be used as a mobile heater) The rail is intended only for panels installed vertically; however, the installation itself is very easy. The openings in the back part of the rail are simply placed onto the top two screws of the panel by which the heater will be attached to the wall. The panel is then placed into the prepared hanging brackets. After the attachment nuts have been tightened, the rail, which is placed between the back part of the panel and the hanging bracket, is attached fi rmly. The rail is in the shape of a rectangle with the dimensions mm; the distance between the attachment openings is 260 mm TYPE Description Weight [kg] Simple towel rail (width 500 mm) GR (SET) 300 0, Simple towel rail (width 600 mm) GR (SET) 500 and 700 1, Simple towel rail (width 800 mm) GR (SET) 900 1, Double towel rail (width 500 mm) GR (SET) 300 1, Double towel rail (width 600 mm) GR (SET) 500 and 700 2, Double towel rail (width 800 mm) GR (SET) 900 2, NOTIFICATION ECOSUN, MR and GR radiant panels are only equipped with a limiting thermostat suitable regulation is essential for correct and economical operation; see the chapter THERMOSTATS AND CONTROLS. In the case of GR and GR SET glass panels, the limiting thermostat switches off the panels at an average temperature of 90 C, and therefore the real thermal output of the panels is approximately 10 % lower than the wattage. For this reason and also for the improvement of the dynamics of the whole heating system, we recommend that the installed wattage is increased by 20 % in contrast with the result of the heat loss calculation. GR and GR SET panels can be supplemented with chromium-coated supports which enable the panel to be placed on the fl oor e.g. in proximity to glass surfaces or to create a stylish portable heater. 8

9 IRC PANELS radiant heating for infrared cabins The principle behind infrared cabins (infrared saunas) In infrared cabins (also called infrared saunas), so-called radiant heat is used it works on a similar principle to ECOSUN heating panels. In this case, however, it is aimed at warming the muscle tissue of the user up to a depth of approximately 4 cm with the help of infrared radiation. Thanks to this deep warming of the organism, intensive sweating takes places at a lower air temperature than in the case of classic steam saunas during the whole of the user s stay in the cabin, the air temperature ranges between 30 and approx. 55 C. Infrared cabins can be used over longer intervals, with the aim of freeing one s body from harmful substances which are released when sweating, or in shorter intervals in which the aim is to warm up the muscle tissue before expected physical exercise muscle stretching, body-building, running etc. Advantages of infrared cabins with IRC panels Infrared heating warms up the skin faster and the heat also penetrates deeper into the tissues than heat from hot steam Thanks to the lower air temperatures involved, they are also suitable for patients with cardiovascular diseases or respiratory diseases In contrast with other types, they have considerably lower acquisition costs and minimum negative infl uences on the surrounding environment humidity The operation costs are lower by 1/3 to 1/2 in comparison with steam saunas (lower air temperature in the cabin; up to 80 % of energy is used for direct heating of the body) Large-surface IRC radiant panels heat evenly across their whole surface and for example in contrast with ceramic radiators, the performance of which is concentrated into a small surface with a high temperature, they heat the whole body signifi cantly better and more evenly The possibility of minimizing spatial requirements a cabin can be installed in an area as small as 1 m 2 suitable also for smaller fl ats Modular assembly without the necessity to use special tools in connection with the IRT regulator the option of assembling the infrared cabin without expert aid 9

10 IRC RADIANT PANELS FENIX has manufactured and supplied IRC panels for foreign producers of infrared cabins (Austria, Germany) since Now it is offering these panels on the Czech market together with a control unit IRT regulator and this also as a DIY kit. IP 44 PRODUCT Output Voltage [V] Weight [kg] Dimensions [mm] IRC Panel 1130x360/ , IRC Panel 1130x780/ , IRC Panel 1130x780/575 S (with a probe) , Wooden frame 1205x435 (for IRC 1130x360) Wooden frame 1205x855 (for IRC 1130x780) CONTROL UNIT IRT 01 REGULATOR The IRT regulator maintains a set temperature on the surface of radiant panels, as well as the required operating time of the heating and lighting of the infrared cabin. It contains a power unit (installed within a cavity under the bench) to which IRC panels are connected using plugs, and also a control unit, light and supply cable. Up to 6 IRC panels can be connected. All IRC panels are equipped with a special connector and the offered sizes can be combined as needed; however, the total wattage mustn t exceed 3.4 kw and one (only one) of the panels used must have an integrated temperature sensor. The power unit is connected to a 230 V socket, protected with a 30 ma residual current device. IP 44 DESCRIPTION IRT 01 REGULATOR Temperature setting C; time setting 1 to 99 minutes; switch Set contents: control unit including a connection cable; power unit with connectors; 3 m power cable with plug (230 V / 16 A); 3 m connection cable for lighting (light is not included in the set); instructions; screws 8 pcs Set selection According to the size of the infrared cabin you wish to install, choose and combine the offered panel sizes in such a way that they best cover the space within the infra-red cabin the lower and upper halves of the body. It is ideal if the panels surround the user on at least three sides. There can be a maximum of six panels for every control unit, from which one (but only one) must be equipped with an integrated temperature probe. The maximum wattage of all the panels attached to one control unit can be up to 3.4 kw. An IRT-01 regulator is necessary to control the panels. The regulator comes with the set, which includes a control panel and power unit. The control panel should be installed inside the infrared cabin within reach of the user. The power unit is installed in a cavity under the bench and should not be easy to access. The connecting leads for the IRC panels are, after installation on the wall, connected to the power unit with the aid of connectors the connectors from the panels, lighting, control units and connecting leads have different dimensions, so it isn t possible to confuse them and connection can be carried out by a non-expert user. If lighting is required it is also possible to connect a light to the power unit; a connection cable comes as part of the set. It is necessary to equip panels with a suitable protective cover, allowing the correct operation of the panel. We recommend using the wooden covering frames that are offered, as they are constructed size-wise to exactly fi t the dimensions of the IRC panels Wooden frames not only fulfi l a protective function, but also attach panels to walls the panels alone are not fi tted with any mounting apertures or brackets. 10

11 ECOFLOOR underfl oor heating systems ECOFLOOR electric fl oor heating systems ensure ideal heat distribution and, by decreasing undesirable air circulation, reduce dust levels. These systems offer great comfort, economic and reliable operation, and long lifetime. They preserve free fl oor space by eliminating the need for various heating elements, radiators and heat distribution systems. The principal advantage of electric fl oor heating is easy and separate temperature control in individual rooms. Once installed, it is completely maintenance free. We provide 10 year warranty for underfloor heating cables and mats and 2 year warranty for cables used for outdoor application (gutter, eaves, pipes). 11

12 Overview of ECOFLOOR heating cables and recommended usage Type Wattage [W/m] Number of heating cores Protective screen Protection against UV radiation Cable composition markings Thermal endurance of the jacket Supplied as circuit Supplied as mat Direct-heating Floor heating Semi-storage Storage Surfaces Anti-freeze protection of 10 ASL1P C ADSV C 18 ADSV-T C 10 ADSV C 20 ADSA C 10 ADPSV C PV (P1P) 1 70 C PSV 1 70 C MAPSV C C MADPSP C* 30 PDSP C 200 C* PFP C PDS1P C 10 ELSR-M 2 65 C ELSR-N 2 80 C 30 Roofs Pipes Overview of ECOFLOOR heating mats and recommended usage Type Wattage [W/m] Number of heating cores Protective screen Protection against UV radiation Thermal endurance of the jacket *) for a short term (installation under asphalt) Direct-heating Floor heating CM C ADSA 80 LDTS C ADSV-T 160 LD C ASL1P 100 LSDTS 2 70 C ADSV-T 160 LPSV C PSV 160 MST 1 80 C MAPSV 300 MDT C MADPSP Cable ASL1P heating mats LD Cable ADSV-T heating mats LDTS, LSDTS Cable ADSV heating circuits ADSV Semi-storage Storage Heating of outdoor areas Type of heating cable MADPSP Linear input of cable [W/m] Total input of circuit Cable ADSV+ heating circuits ADSV+ Cable ADSA ultrathin mats CM 1 Resistance (heating) wire M multi-resistance stranded resistance wire (to be used for higher outputs); No letter is used for a non-stranded (simple) resistance wire 2 Core insulation A FEP (fl uoropolymer) XLPE (cross-linked polyethylene) P 3 Number of heating cores D double-core cable; No letter is used for a single-core cable 4 Plastic insulation (for outdoor applications, higher mechanical ruggedness of cable) P XLPE (cross-linked polyethylene); No letter is used for a cable without the second plastic insulation 5 Protection screen (for wet areas) S full screen protection (tinned copper wires and aluminium tape) SL linear screen protection No letter is used for a cable without screen protection 6 Jacket XLPE (cross-linked polyethylene) P 1P PP-LDPE (mixed polypropylene & low density PE) V PVC (polyvinyl chloride) Cable PV heating circuits PV (earlier P1P) Cable PSV heating circuits PSV Cable ADPSV heating circuits ADPSV Cable MAPSV heating circuits MAPSV, heating mats MST Cable MADPSP heating circuits MADPSP, heating mats MDT Cable PDSP heating circuits PDSP Cable PDS1P for curing concrete Cable ELSR-M self-regulating cable for anti-freeze protection and technological heating (10 and 15 W/m) Cable ELSR-N self-regulating cable for anti-freeze protection and technological heating (20 and 30 W/m EExII) 12

13 DIRECT HEATING SYSTEMS ECOFLOOR CABLES AND MATS ECOFLOOR heating systems are available in two basic variants heating cable circuits and heating mats. In fact the two systems do not differ from one another very much. In both cases, the heating system consists of a heating cable, either separate or fi xed to a supporting fi breglass cloth (heating mat). This modern fl oor heating system permits easy and effective regulation. The heating cable circuit or mats are placed directly beneath tiles in a thin layer of permanently fl exible cement so the tiled surface heats up relatively quickly (circa 20 min). Temperature control is sensitive and quick to react. Heating cable circuits or mats are suitable for renovated fl oors where the fi nal fl oor height is not a constraint. DIRECT HEATING SYSTEM 1 wear layer (ceramic fl oor tiling) 2 fl exible bonding cement 3 ECOFLOOR heating mat 4 fl oor (limitation) probe in a protective tube (so-called goose neck) 5 load-bearing concrete fl oating board 6 steel reinforcement (so-called Kari mesh) 7 thermal insulation 8 base (concrete board) DIRECT HEATING SYSTEM RECONSTRUCTION 1 wear layer (ceramic fl oor tiling) 2 fl exible bonding cement 3 heating mat (cable) ECOFLOOR 4 fl oor (limitation) probe in a protective tube (so-called goose neck) 5 F-BOARD supplementary thermal insulation (shortens the warming time) (see page 23) 6 fl exible bonding cement 7 original fl oor (old fl oor tiling, concrete) 13

14 ECOFLOOR HEATING MATS LDTS or LSDTS (self-adhesive) heating mat, twin conductor cable with a full protection screen, width 50 cm, cold lead 1 3 m. LDTS mats are provided with selfadhesive tape for affi xing to the fl oor. LSDTS mats have a self-adhering mesh on their entire back surfaces. LDTS / LSDTS packing LDTS / LSDTS 160 W/m 2 Type 160 W/m 2 Surface [m 2 ] Length LDTS LSDTS /0.5 0,5 0, /0.8 0,8 1, /1.3 1,3 2, /1.6 1,6 3, /2.1 2,1 4, /2.6 2,6 5, /3.0 3,0 6, /3.4 3,4 6, /4.2 4,2 8, /5.1 5,1 10, /6.1 6,1 12, /7.6 7,6 15, /8.8 8,8 17, / ,0 22, / ,3 26, / ,3 32, LDTS / LSDTS heating mat LDTS / LSDTS 100 W/m 2 Type 100 W/m 2 Surface [m 2 ] Length LDTS LSDTS /0.6 0,6 1, /1.0 1,0 2, /1.8 1,8 3, /2.2 2,2 4, /2.9 2,9 5, /4.1 4,1 8, /4.7 4,7 9, /5.6 5,6 11, /8.2 8,2 16, / ,2 20, / ,8 23, / ,9 35, LDTS 160 W/m 2 LDTS 80 W/m 2 Type Surface 160 W/m 2 [m 2 ] Type Surface 80 W/m 2 [m 2 ] Length Length LDTS ,5 0,5 1, ,0 2, ,5 1,5 3, ,0 4, ,5 2,5 5, ,0 6, ,5 3,5 7, ,0 8, ,0 10, ,0 12, LDTS 60 80/0.8 0,8 1, /1.3 1,3 2, /2.3 2,3 4, /2.8 2,8 5, /3.6 3,6 7, /5.1 5,1 10, /5.8 5,8 11, /7.0 7,0 14, / ,3 20, / ,5 25, / ,0 30, / ,5 45, LD heating mat, single conductor cable with a full protection screen, width up to 3 m 2 30 cm, over 3 m 2 50 cm, cold lead 2 5 m LD mat Packing in PE foil. LD 160 W/m 2 Type LD Surface Width Length 160 W/m 2 [m 2 ] /0.6 0,6 0,3 2, /0.9 0,9 0,3 3, /1.1 1,1 0,3 3, /1.8 1,8 0,3 6, /2.3 2,3 0,3 7, /3.0 3,0 0,3 10, /4.3 4,3 0,5 8, /5.3 5,3 0,5 10, /5.9 5,9 0,5 11, /7.2 7,2 0,5 14, / ,7 0,5 21, / ,4 0,5 24, / ,7 0,5 31, / ,8 0,5 37, ULTRA THIN CM MATS a very thin two conductor cable with a protective screen suitable for damp areas (bathrooms, laundry rooms) as well as for standard rooms ideal for placement into adhesive sealing cement directly under floor tiling; Ø of cable mm, cold lead m. CM 150 W/m 2 Type Surface [m 2 ] Length 150 CM150/1 1,0 2, CM150/1,5 1,5 3, CM150/2 2,0 4, CM150/2,5 2,5 5, CM150/3 3,0 6, CM150/4 4,0 8, CM150/5 5,0 10, ECOFLOOR Installation Heating Mat 1) Unroll the heating mat according to the layout drawing. 2) If you need to leave a space under fi xed furniture, cut out the necessary part of the cloth and span the space with the cable (see fi g. 2). 3) Level the layer of fl exible cement with a smooth trowel. 4) Lay tiling on small areas (up to 4 m 2 ) immediately, and on larger areas after 24 hours. 14

15 ECOFLOOR HEATING CABLE CIRCUITS ADSV heating cable, a twin conductor cable with a full protection screen suitable for wet areas. For direct fl oor heating or fl oor renovating (installation under tiles). Cable diameter mm. Cold tail 1 3 m. Cables on drums TYPE (Ohm/m) 122, , , , , , , , , , , , , , , Cable on drum Heating circuits Type ADSV 10 W/m , , , , , , , , , , , , , , , Type ADSV 15 W/m Cable circuit on carton reel. Standard packing , , , , , , , , , , , , , Type ADSV 18 W/m Packing in carton box available , , , , , , , , , , , , , , ASL1P heating cable, a single-conductor cable with a full protection screen suitable for wet areas. For direct fl oor heating (installation under tiles). Cables on drums TYPE (Ohm/m) 61, , , , , , , , , , , , , Cold lead 2 5 m. Cable diameter mm. Packing in PE foil. Heating circuits Type ASL1P 10 W/m , , , , , , , , , , , Type ASL1P 15 W/m , , , , , , , , , , , Type ASL1P 18 W/m , , , , , , , , , , ECOFLOOR Installation Heating Cable Circuit 1) Create loops of the heating cable across the entire base (a spacing guide may be used, as shown). 2) Fix the cable to the base using the self-adhesive tape or GRUFAST fastening strips. 3) Level the layer of fl exible cement with a smooth trowel. 4) Lay tiling on small areas (up to 4 m 2 ) immediately, and on larger areas after 24 hours. 15

16 KITS FOR DO-IT-YOURSELF INSTALLATION Kits for do-it-yourself installation have been designed for those users who do not want a complete electrical heating system but a comfortable, warm fl oor in a specifi c area (e.g. bathroom or kitchen). The kits include everything needed to install the fl oor heating system and are very reasonably priced. They are sold in two variants: ECOFLOOR CableKit ECOFLOOR ComfortMat Type CK (10 W/m) AREA [m 2 ] AREA [m 2 ] AREA [m 2 ] 160 W/m W/m W/m ,4 0,5 0,65 6, ,75 0,95 1,2 11, ,25 1,6 2,0 18, ,6 2,0 2,5 23, ,0 2,6 3,2 31, ,5 3,2 4,0 36, ,8 3,6 4,5 45, ,25 4,0 5,2 49, ,75 4,8 6,0 63, ,7 6,1 7,5 75, ,9 7,7 9,5 87, ,9 8,9 11,0 114, ,1 10,5 13,0 131, ,6 13,1 17,0 158, ,5 16,2 20,0 194, Cable kit includes heating cable ADSV on carton reel thermostat Fenix Therm 100 with fl oor sensor protection tube for fl oor sensor adhesive fi xing tape template to plane cable runs for 100 W/m 2, 130 W/m 2 and 160 W/m 2 installation manual Type CM AREA 160 W/m 2 [m 2 ] ,5 0, ,8 1, ,3 2, ,6 3, ,1 4, ,6 5, ,0 6, ,4 6, ,2 8, ,1 10, ,1 12, ,6 15, ,8 17, Type CM AREA 100 W/m 2 [m 2 ] ,9 3, ,2 4, ,9 5, ,1 8, ,7 9, ,6 11, ,2 16, Width of the heating mat is 50 cm Comfort mat includes heating mat LDTS digital thermostat Aube TH 132 AF with fl oor sensor protection tube for fl oor sensor installation manual It is recommended that you install F-Board insulated tile backer board before laying CK or CM. This will ensure quicker warm up times and reduce running costs (see page 23). 16

17 SEMI-STORAGE AND STORAGE HEATING ECOFLOOR CABLES AND MATS Heating cables or mats in semi-storage systems are placed in a layer of concrete 4 5 cm thick. The mat s recommended output wattage is 160 W/m 2. Heat is accumulated for 16 hours a day at a time when electricity costs are lowest. The accumulated heat is radiated from the fl oor surface not only during the process, but also for a further 8 hours. One effi cient solution is to divide the total desired heating system 70/30 between the fl oor heating and another source, such as a convection heater or an ECOSUN radiant panel. SEMI-STORAGE SYSTEM 1 wear layer (fl oor tiling, carpet, PVC, laminate) 2 fl oor (limitation) probe in a protective tube (so-called goose neck) 3 load-bearing concrete fl oating board 4 steel reinforcement (so-called Kari mesh) 5 ECOFLOOR heating mat (cable) 6 thermal insulation 7 base (concrete board) Storage fl oor heating is a system that takes advantage of cheaper electricity tariffs usually at night. During this time, heat is accumulated into the mass of the fl oor using ECOFLOOR electrical heating cables or mats. Throughout the rest of the day, the heat is gradually released from the fl oor to the room. In storage systems, heating mats or cables are placed in a layer of concrete 10 to 14 cm thick. The accumulated stored heat is then released during the day into the area to be heated. We recommend an output wattage of 250 to 300 W/m 2 for ECOFLOOR mats used in this type of system. Eight hours of low-tariff electricity should be used to accumulate the heat. STORAGE ECOFLOOR HEATING 1 wear layer (fl oor tiles, carpet, PVC, laminate) 2 fl oor (limitation) probe in a protective tube (so-called goose neck) 3 concrete storage layer 4 ECOFLOOR heating mat (cable) 5 concrete storage layer 6 steel reinforcement (so-called Kari mesh) 7 thermal insulation 8 base (concrete board) 17

18 ADPSV heating cable, a twin conductor cable with a full protection screen is suitable for semi-storage and storage floor heating in living areas. Class M2. Cold lead 1 5 m. Ø mm. LPSV heating mat, single conductor cable with a full protection screen, width 50 cm, cold lead 2 5 m. Packed on a cardboard tube and sealed in PE foil. Type ADPSV 18 W/m , , , , , , , , , , , , , , ADPSV cable circuit a twin conductor cable ADPSV packing Type LPSV Surface 100 W/m 2 [m 2 ] Length 180 LPSV 1,8 1,8 3, LPSV 3 3,0 6, LPSV 3, 3,7 7, LPSV 3,7 4,8 9, LPSV 5,8 5,8 11, LPSV 7 7,0 14, LPSV 7,7 7,7 15, LPSV 8,5 8,5 17, LPSV 9,4 9,4 18, LPSV 10,5 10,5 21, LPSV11,5 11,5 23, LPSV 14 14,0 28, LPSV 17 17,0 34, LPSV 20 20,0 40, LPSV 25 25,0 50, PSV heating cable, a single-conductor cable with a full protection screen for storage and semi-storage heating. Cables on drums TYPE (Ohm/m) 19, , , , , , , , , , , , , , , , Cold lead 2 5 m. Cable diameter mm. Heating circuits Type PSV 10 W/m , , , , , , , , , , , , , , , , Type PSV 15 W/m , , , , , , , , , , , , , , , , PSV cable circuit a single-conductor cable with 2 5 m cold leads. Packing in PE foil. PV heating cable, a single-conductor cable without a protection screen for storage and semi-storage heating. Cables on drums TYPE (Ohm/m) 19, , , , , , , , , , , , , , , , Cold lead 2 5 m. Cable diameter mm. Heating circuits Type PV 10 W/m , , , , , , , , , , , Type PV 15 W/m , PV cable circuit a single conductor cable with 2 5 m cold leads. Packing in PE foil. 18

19 OUTDOOR APPLICATIONS Ice and snow melting Installing electric heating cables in outdoor areas, together with a thermostat, prevents both ice formation and snow accumulation. Once installed, the system works entirely automatically and is only operational when it is snowing or if ice is forming on roads and walkways. De-icing gutters and eaves troughs In all parts of Europe other than in the south, winter brings a heavy load to many buildings as ice builds up in the gutters and eaves troughs. Installing an ECOFLOOR electric heating cable (with a protective screen) into gutters and eaves troughs is a good solution for such problems. The cables are installed using special plastic clips placed inside gutters and eaves troughs. We recommend a linear wattage of 20 W/m for the de-icing cables. Frost protection of pipes Many homeowners and other users of piping have many troubles in the winter due to freezing pipes. This especially applies to pipes for water piping, but other liquids used in industrial technologies can also freeze or solidify. During long spells of below-freezing temperatures, even very well-insulated piping can freeze. Supplementary heating is a reliable preventive solution. 19

20 MAPSV heating cable, a single-conductor cable with a full protection screen and protection against UV radiation. Suitable for heating outdoor surfaces. Cold lead 2 5 m. Ø mm. 30 W/m for removing ice and snow from roofs and gutters. Must be used control system with air temperature and moisture sensor protecting cables to switch-on in temperature more than +5 C. TYPE Suitability Max. loading Floor heating in living areas Yes 30 W/m Outdoor surface heating Yes 30 W/m Frost protection of pipes Yes 15 W/m Pipe heating Yes 15 W/m Removing ice and snow from roofs and gutters Yes 30 W/m Cables on drums TYPE (Ohm/m) 9, , , , , , , , , , , , , MAPSV cables 400 V Heating circuits Type MAPSV 20 W/m , , , , , , , , , , , , , Type MAPSV 20 W/m 400 V , , , , , , , , , , , , , Type MAPSV 25 W/m , , , , , , , , , , , , , Type MAPSV 30 W/m 400 V , , , , , , , , , , , , , Type MAPSV 30 W/m , , , , , , , , , , , , , MST mats, 230 V, width 0,5 m Type MST AREA 300 W/m 2 [m 2 ] MST 300/1,5-0,5 1,5 3, MST 300/2-0,5 2,0 4, MST 300/3-0,5 3,0 6, MST 300/4-0,5 4,0 8, MST 300/5-0,5 5,0 10, MST 300/6-0,5 6,0 12, MST 300/7-0,5 7,0 14, MST 300/8-0,5 8,0 16, MST 300/9-0,5 9,0 18, MST 300/10-0,5 10,0 20, MST 300/12-0,5 12,0 24, MST 300/15-0,5 15,0 30, MST 300/20-0,5 20,0 40, MST mats, 400 V, width 0,5 m Type MST AREA 300 W/m 2 [m 2 ] MST 300/3-0,5 3,0 6, MST 300/4-0,5 4,0 8, MST 300/6-0,5 6,0 12, MST 300/7-0,5 7,0 14, MST 300/9-0,5 9,0 18, MST 300/12-0,5 12,0 24, MST 300/14-0,5 14,0 28, MST 300/16-0,5 16,0 32, MST 300/18-0,5 18,0 36, MST 300/22-0,5 22,0 44, Mats MST available also in 1m width. Available wattage 160W/m 2. For easy installation the heating mat MST is provided with 1 5 m cold lead and with other cold lead 1 5 m + lenght of the mat. Cables and mats are packing in PE foil. DRIVEWAY 1 hardened surface, e.g. interlocking pavement 2 humidity sensor (water, snow, ice) 3 sand bed of the interlocking pavement 4 concrete board (protects the heating cable from vehicle load) 5 ECOFLOOR MAPSV/MADPSP heating cable or MST/MDT mat 6 fi rm gravel base (macadam) PAVEMENT 1 hardened surface, e.g. fl oor tiling 2 humidity sensor (water, snow, ice) 3 sand fi ll and the sub-base of the cable 4 ECOFLOOR MAPSV/MADPSP heating cable or MST/MDT mat 5 fi rm gravel base (macadam) 20

21 MADPSP heating cable, a two-conductor cable with a full protection screen and protection against UV radiation. Suitable for heating outdoor surfaces. Class M2. Cold lead 1 5 m. Ø mm. 30 W/m (35 W/m for removing ice and snow from roofs and gutters. Must be used control system with air temperature and moisture sensor protecting cables to switch-on in temperature more than +5 C). TYPE Suitability Max. loading Floor heating in living areas Yes 20 W/m Outdoor surface heating Yes 30 W/m Frost protection of pipes Yes 15 W/m Pipe heating Yes 15 W/m Removing ice and snow from roofs and gutters Yes 35 W/m Cables on dr. TYPE (Ohm/m) 18, , , , , , , , , , , , Heating circuits MADPSP 15 W/m , , , , , , , , , , , , MADPSP 20 W/m , , , , , , , , , , , , MADPSP 25 W/m , , , , , , , , , , , , MADPSP 30 W/m , , , , , , , , , , , , MADPSP cable, 400 V MADPSP 20 W/m 400 V , , , , , , , , , , , MADPSP 30 W/m 400 V Cables and mats are packing in PE foil , , , , , , , , , , , MDT mat, 230 V, width 0,5 m MDT AREA 300 W/m 2 [m 2 ] MDT300/0,9 0,5 0,9 1, MDT300/1,5 0,5 1,5 3, MDT300/2,3 0,5 2,3 4, MDT300/2,7 0,5 2,7 5, MDT300/3,5 0,5 3,5 7, MDT300/4,5 0,5 4,5 9, MDT300/5 0,5 5,0 10, MDT300/6,3 0,5 6,3 12, MDT300/7,8 0,5 7,8 15, MDT300/13,3 0,5 13,3 26, MDT mat, 400 V, width 0,5 m MDT AREA 300 W/m 2 [m 2 ] MDT300/1,8 0,5 1,8 3, MDT300/2,9 0,5 2,9 5, MDT300/4,5 0,5 4,5 9, MDT300/5,2 0,5 5,2 10, MDT300/6,7 0,5 6,7 13, MDT300/8,7 0,5 8,7 17, MDT300/9,3 0,5 9,3 18, MDT300/12 0,5 12,0 24, MDT300/15 0,5 15,0 30, MDT300/25,7 0,5 25,7 51, The heating mat MDT is provided with 1 5 m cold lead PFP automatic heating cable with a thermostat, electrical socket connection, the thermostat switches on at +3 C, 1,5 m connection cable with plug, IP 66 coverage. FOOTBALL PITCH 1 grass 2 soil layer, approx. 30 cm thick 3 sand bedding, approx. 7 cm (compacted) and approx. 3 cm thick fi ll 4 ECOFLOOR MAPSV/MADPSP heating cable or MST/MDT mat (approx. 20 W/m, 100 W/m 2, cable loop spacing 20 cm) 5 Levelled solid base (grown, soil) Type PFP RESISTANCE [Ω] 20 PFP 2m/20W PFP 3m/30W PFP 4m/40W PFP 6m/72W PFP 10m/136W PFP 14m/152W PFP 21m/281W PFP 30m/337W PFP 42m/490W

22 ADSV+ heating cable, a two-conductor cable with a full protection screen. The sheathing of the cable is resistant against UV radiation and is intended for fl oor heating and the removal of snow and ice from roofs and eaves troughs. 1 3 m cold lead. Ø 5.0 mm. TYPE Suitability Max. loading Floor heating in living areas Yes 20 W/m Outdoor surface heating No Frost protection of pipes Yes 10 W/m Pipe heating Yes 10 W/m Removing ice and snow from roofs and gutters Yes 20 W/m Heating circuits Type ADSV+ 10 W/m , , , , , , , , , , , , , , Type ADSV+ 18 W/m , , , , , , , , , , , , , , Type ADSV+ 20 W/m , , , , , , , , , , , , , , ADPSV heating cable, a twin conductor, full protection screened cable with protection against UV radiation. This multipurpose cable is suitable for indoor and outdoor applications. Class M2. Cold lead 1 5 m. Ø mm. TYPE Suitability Max. loading Outdoor surface heating Yes 20 W/m Frost protection of pipes Yes 10 W/m Pipe heating Yes 10 W/m Removing ice and snow from roofs and gutters Yes 20 W/m Cables on drums TYPE (Ohm/m) 38, , , , , , , , , , , , , , Heating circuits Type ADPSV 20 W/m , , , , , , , , , , , , , , Type ADPSV 10 W/m , , , , , , , , , , , , , , ADPSV cable. Packing on carton reel. PDSP heating cable, a two-conductor cable with a full protection screen and protection against UV radiation. Suitable for heating outdoor surfaces. Class M2. Cold lead 1 5 m. Outer cable diameter oval mm. TYPE Suitability Max. loading Floor heating in living areas Yes 28 W/m Outdoor surface heating Yes 28 W/m Removing ice and snow from roofs and gutters Yes 28 W/m Must be used control system with air temperature and moisture sensor protecting cables to switch-on in temperature more than +5 C. Heating circuits (Ohm/m) PDSP 28 W/m 3, , , , , , , , , , STAIRS 1 wear layer (fl oor tiling) 2 fl exible bonding cement 3 ECOFLOOR ADPSV/MAPSV/ MADPSP/PDSP heating cable 4 stairs 22

23 SPECIAL APPLICATIONS CONCRETE CURING CABLE CIRCUITS A twin conductor screened cable with a 1 2 m cold lead with plug connection Type PDS1P 40 W/m , , , , PDS1P cable for curing concrete. Packing in PE foil. THE D-MAT HEATING SHEET Is intended for outdoor use as anti-freeze protection in industrial applications and in the construction industry for example, for the warming of the earth in excavation pits or of stored friable materials, the warming of cables on reels, maintenance of warmth in parts of machines or in tools, etc. The sheet is also suitable for use in extreme winter conditions. Technical parameters: IP 56 coverage; heated area m (3.4 m 2 ); total sheet dimensions m; 5 m supply lead ends in a SCHUKO plug. Type D-MAT 280 W/m DM 3,4/ SELF-REGULATING CABLES The ELSR self-regulating cables are parallel electrical heating strips consisting of a specially fi nished plastic with embedded carbon particles that create an electrical path between two parallel copper bus bars. Marking Output W/m Temperature Limitation for instalation Max. length at the 10 C tolerance [ C] Min. temp. Min. radius temperature setting ELSR-M Frost protection of pipe 6 A 10 A 16 A ELSR-M 10 BO C 35 mm 65 m 95 m 105 m ELSR-M 15 BO C 35 mm 37 m 58 m 65 m ELSR-N Frost protection of trays, gutters, roofs, technological heating 16 A 20 A 25 A ELSR-N 20 BO C 20 mm 94 m 116 m 146 m ELSR-N 30 BO C 20 mm 70 m 87 m 109 m KIT Nr. 4 For connection and termination of self-limiting cables Cold lead for self-regulating cables SK 1,5 Limitation: 12 A / 20 m SK 2,5 Limitation: 20 A / 20 m SK 4 Limitation: 20 m Industrial applications: Analyzer lines prevent condensation Cooling water lines anti-freeze protection Potable water lines anti-freeze protection Caustic soda prevent crystallization under 30 C Oils and fats maintain pumpable viscosity Heating oil prevent wax dispersion Vessel anti-freeze and condensation protection F-BOARD FLOOR INSULATION F-boards prevent heat losses to the subfl oor structure. Recommended for fl oor reconstructions. Type Dimensions [mm] Thickness [mm] Packaging Packets on the [boards in packet] pallet F-BOARD F-BOARD Useful information Dimensions Thickness Weight (kg/board) 600 mm 1250 mm (0,75 m 2 each) 6 mm or 10 mm 1,8 (6 mm) 2,0 (10 mm) Material Extruded Polystyrene core with Polymer cement outer skin Density 32 kg/m 3 Thermal Conductivity 0,029 W/m k Compresive strenght 300 kn/m 2 Floor Tiles Tile Adhesive ECOFLOOR Mat F-BOARD Tile Adhesive Water absorption (immersion) Water absorption (capillary) Co-effi cient of Linear Expansion Flamibility < 1,5 % by vol Nil 0,07 mm/mk B1 Sub-Floor or Existing Floor (before renovation) 23

24 ECOFLOOR ACCESSORIES Product Description Quantity supplied Gutter clip 25 pcs Downpipe clip 25 pcs Chain (1 m = 22 links) 10 m GRUFAST fastening strip, 1 unit=10m 1 unit Plastic cable clip 50 pcs Ecofl oor strip, 0.5 m length Flex strip, 0.5 m length T strip, 0.5 length REPAIR KIT Kit no. 1 for P1P cable repair Kit no. 2 for ADSV, ASL1P Mat LD and LDTS cable repair Kit no. 3 for PSV, MADPSP and ADPSV cable and mat repair Kit no. 4 for connection and termination of self-limiting cables Kit no. 5 for MADPSP installed under asphalt OTHER ACCESSORIES Aluminium self-adhesive tape, 50 mm width, 50 m length SYFOK-B fi xation cables for nonstandard eaves and valleys B/20 (20 m) B/10 (10 m) SYFOK-P fi xation cables for nonstandard eaves, gutters and valleys P/20 (20 m) P/10 (10 m) Cable spacer for 4,5 cm loops 25 pcs C-shaped copper roof spacer 25 pcs Eaves trough clip Chain Gutter clip 24

25 ECOFILM Ecofi lm heating fi lms use state of the art technology and are primarily used for heating large surfaces. These heating systems are composed of laminated polyester fi lms with a graphite coating, supply leads, and accessories. We offer ECOFILM fi lms in 3 versions: underfl oor heating fi lms ( F ), ceiling fi lms ( C ) and mirror heating fi lms. heating fi lm The F fi lm is installed directly beneath a fl oating fl oor. Due to its ultra thin profi le (max 0,4 mm thick) the original construction height of the fl oating fl oor is hardly affected. This silent, unobtrusive and dry-laid underfoot heating system is highly reliable and has a long life span. We provide a 10-year warranty for ECOFILM heating fi lms, however their operational life can be longer (30 50 years). The product has been tested according to European standards. ECOFILM set The do-it-yourself kit for underfl oor heating may be installed easily, quickly by following the relevant instructions. No professional installation company required. The fi nal electrical connection must be carried out by a qualifi ed electrician. As the Ecofi lm set comes complete for installation, no accessories are needed. We recommend 60 W/m 2 for a fl oating wooden fl oor and 80 W/m 2 for a fl oating laminated fl oor. The Ecofilm set includes: Ecofi lm F608/55 (F606/55, 1008) electrical heating fi lm delivered in rolls of various lengths according to the customer s requirements and layout plan. The heating fi lm is supplied with insulated cut edges and cold leads. An additional pair of insulation discs for insulating the copper electrodes of the heating fi lm in the event that there is a requirement to shorten the length of the heating fi lm. Installation manual. The fi lm is fi tted with two SK AV1.5 cold leads 3 mm in diameter and 5 m long. TYPE WIDTH [mm] Output Total (W/m 2 ) Output TOTAL ACTIVE Eset 60-1,5/50 1, Eset 60-2/ Eset 60-2,5/83 2, Eset 60-3/ W/m Eset 60-4/ (230 V) Eset 60-5/ Eset 60-6/ Eset 60-8/ Eset 60-10/ Eset 80-1,5/66 1, Eset 80-2/ Eset 80-2,5/110 2, Eset 80-3/ W/m Eset 80-4/ (230 V) Eset 80-5/ Eset 80-6/ Eset 80-8/ Eset 80-10/ Eset 80-2/156 1, Eset 80-1,5/ Eset 80-2/156 2, Eset 80-2,5/ W/m Eset 80-4/ (230 V) Eset 80-5/ Eset 80-6/ Eset 80-8/ Eset 80-10/ Simplified Example of ECOFILM Set Design Total surface area m. Heating under laminated fl oor. Recommended application: ECOFILM Set 80 W/m 2. Note: Heating Parts of the film must not overlap and their minimal distance from fixtures and wall shall be 5 cm. Owing to the following note, 3 fi lm strips (1000 mm wide) 3 m long and 2 m long and 2 fi lm strips (600 mm wide) 3 m and 2 m long may be used. For the given application it is recommended 2 Eset 80-3/234, 1 Eset 80-3/132, 1 Eset 80-2/156 and 1 Eset 80-2/88 + temperature control. WAGO WAGO 25

26 ECOFILM F underfl oor heating fi lm Flexible Ecofi lm heating fi lm is the ideal solution for economical electric underfl oor heating for laminated and wooden fl oating fl oors. The product is ultrathin, yet robust, and is a dry-laid system that is easy to install. Easy, precise and fast installation The heating fi lm is produced in rolls 600 mm wide (550 mm heating surface, two 25 mm non-heating edges) and mm wide (970 mm heating surface, two 15 mm non-heating edges). Thanks to its special material composition, the heating fi lm may be cut every 10 mm to obtain exactly the required length of strips. The strips are laid side-by-side across the entire heating surface and are interconnected in parallel using cables with connectors. ECOFILM F heating components must neither overlap nor cross one another. This method of laying the fi lm saves time and especially reduces labor costs. Installers will appreciate that the fl oating or wooden fl oor may be laid immediately after the heating fi lm is installed and connected. Gentle and safe heating for your comfort Heating fi lm makes an ideal fl oor heating system for laminated or wooden fl oating fl oors. The technical parameters of the heating fi lm ensure that the materials temperature resistance values are observed. Health safety standards are also maintained too as the maximum fl oor surface temperature is thermostatically limited to 27 C. Traditional heaters which utilise a liquid to transfer the heat,operate at for example, signifi cantly higher temperature sand results in a greater fl uctuation in air humidity and undesirable effects on wooden and laminated fl oors. It is hardly surprising that this sophisticated system has been used to safely and comfortably heat in excess of 2,5 million m 2 of fl oors throughout Europe and has been warmly endorsed by such leading fl oor manufacturers as PERGO, SCANDIFLOOR, ALLOC, KÄHRS and JUNCKERS. TYPE * WIDTH [mm] TOTAL ACTIVE Output [W/m 2 ] Output [W/m] Laminate, wood or real timber floor ECOFILM F 608/ ECOFILM F 606/ ECOFILM F 604/ ECOFILM F ECOFILM F Other types of floor film ECOFILM F ECOFILM F ECOFILM F ECOFILM F *) delivered in roll, order accessories required for installation ideal temperature characteristic under-fl oor heating temperature characteristic ECOFILM F with accessories ECOFILM F connection in parallel with Mastic Sectional view of laminated (wooden) floor (reconstruction) 1 three-layer wooden or laminate fl oating fl oor 2 fl oor (limitation) probe in a groove 3 PE foil covering, 0.25 mm thick 4 ECOFILM fl oor heating foil 5 insulation underlay from extruded polystyrene 6 base concrete, anhydrite, original fl oor etc. Illustration photo installation of ECOFILM F608 under fl oating fl oor 26

27 ECOFILM C ceiling heating fi lm ECOFILM C heating fi lms provide an ideal ceiling heating system with balanced heat distribution throughout the room (without temperature gradients). Control of the ECOFILM C S temperature I achieved by the use of an electronic thermostat which controls the room temperature. As it is a radiant heating system, the same comfort level as achieved by convection heating may be obtained at lower temperatures. Generally, reducing the temperature by 1 C lowers total heating costs by 6 %. ideal temperature characteristic ceiling radiant heating temperature characteristic ECOFILM C with connected cold lead TYPE * WIDTH [mm] TOTAL ACTIVE Output [W/m 2 ] Output [W/m] ECOFILM C ECOFILM C ECOFILM C ECOFILM C ECOFILM C *) delivered in roll, order accessories required for installation Installation of connector cover Installation: Crimp connector and cold lead Sectional view of ceiling structure 1 load-bearing ceiling structure; 2 thermal insulation; 3 CD load-bearing sections of the plasterboard structure; 4 ECOFILM ceiling heating foil 5 PE foil covering, 0.25 mm thick; 6 plasterboard ceiling (fl oating) Illustrative photos of ECOFILM C installation on metal joists 27

28 ECOFILM MHF mirror fogging prevention MIRROR HEATING FILM perfectly prevents mirror fogging Safety operation. The Ecofi lm MHF fi lm operates at low temperatures and prevents overheating or damage to the mirror. Installation is simple and fast. The MHF fi lm has an adhesive layer (with release backing) that easily sticks to the rear of a mirror. The mirror heater can be wired into the electric circuit of a lighting fi xture so that it is activated whenever the light is switched on. Considering its low input, the heating fi lms operating costs are negligible. The ECOFILM MHF heating fi lm requires no maintenance. WITH MHF WITHOUT MHF TYPE Output Dimension [mm] MHF 12 12, MHF MHF MHF m cold lead ECOFILM ACCESSORIES Product Description Amount supplied Crimp connector for Ecofi lm C and F 1 unit Crimp cover for Ecofi lm C 1 unit black blue Cold lead 1,5 for Ecofilm C 1 m x Cold lead AV 1,5 for Ecofilm F 1 m 66510x0 Cold lead AV 2,5 for Ecofilm F 1 m 66510x0 Crimp tool 1 unit Insulating tape for sealing cut edges of heating film 28 mm width/33 m length 38 mm width/33 m length 1 roll MASTIC VM connector insulation for Ecofi lm F 38 mm width (1 connector requires 0.1 m) 1m WAGO connector (terminal strip) for Ecofi lm set 1 unit HEAT-PAK for the placement of ECOFILM F, ECOFILM SET heating foil under a carpet or PVC This underlay with good thermal conductivity enables the installation of fl oor heating directly under a carpet or PVC when it isn t possible to place the heating cable into a screed (for example in the case of additional installation or reconstruction work). Completely dry installation; raises the fl oor by only 10 mm. The packaging contains 8 boards (4 3 mm thick base boards and 4 4 mm thick covering boards); each of them is coated in a thin layer of adhesive. Laid in two layers, the boards are glued to each other (staggering of joints is necessary in this way, the joints don t show through on the fl oor covering). A rigid, 7 mm thick compact construction is created onto which PVC or carpet can be laid (freely or glued). Sold only as whole packages. 1 wear layer (PVC, carpet); 2 HEAT-PAK 7 mm two-layer glued underlay; 3 fl oor (limitation) probe in the groove (embedded); 4 PE foil covering, 0.25 mm thick; 5 ECOFILM fl oor heating foil; 6 insulation underlay from extruded polystyrene; 7 base original fl oor, concrete anhydrite, etc. Type Thickness [mm] Capacity [kg/m 3 ] Conductivity [W/mK] Strength in fl exure Dimensions of the boards Package [m 2 ] HEAT-PAK 7 3 and ,07 > 40 kg / cm 2 boards 0,6 1,2 2,88 m FLOOR INSULATION under wood/laminate fl oor with ECOFILM F, ECOFILM SET heating foil 1 three-layer wooden or laminate fl oating fl oor; 2 fl oor (limitation) probe in a groove; 3 PE foil covering, 0.25 mm thick; 4 ECOFILM fl oor heating foil; 5 insulation underlay from extruded polystyrene; 6 base concrete, anhydrite, original fl oor etc. Type Thickness [mm] Bulk density [kg/m 2 ] Thermal conductivity coeffi cient [W/mK] Load resistance [t/m 2 ] Dimensions of insulation Package [m 2 ] STARLON ,0315 5,2 0,5 1,0 boards 5, STARLON ,0298 6,7 0,5x1,0 boards 5,

29 ULTRATHERM heating for vivariums and terrariums In 2008 Aztec Europe Ltd. joined FENIX holding. Aztec Europe Ltd. has its seat in Great Britain and focuses on the production of special purpose heating elements using mainly ECOFILM foil. These products include heating systems for vivariums and terrariums. ULTRATHERM HEATING FILMS AND STRIPS Viv Strip heating strips due to their size, Viv Strip heating strips are suitable mainly for the warming of selected areas within a vivarium or terrarium housing specifi c types of reptile. Cold lead 2 m. TYPE Output Voltage [V] Dimensions [mm] Ultratherm Viv Strip Ultratherm Viv Strip V / 50 Hz Ultratherm Viv Strip Ultratherm Viv Strip Viv Mat heating foils Viv Mat heating foils are larger than Viv Strip strips and so are used when it is necessary to heat the majority of the area of a vivarium or terrarium. Cold lead 2 m. TYPE Output Voltage [V] Dimensions [mm] Ultratherm Viv Mat Ultratherm Viv Mat Ultratherm Viv Mat Ultratherm Viv Mat V / 50 Hz Ultratherm Viv Mat Ultratherm Viv Mat Ultratherm Viv Mat Happy Hamster heating foil due to its dimensions this heating foil is suitable for breeders of various types of rodent. Although rodents are not primarily heat-loving animals, in the winter season they enter a certain form of winter hibernation and Happy Hamster heating foil is ideal to help them get through this period in comfort. Cold lead 2 m. TYPE Output Voltage [V] Dimensions [mm] Ultratherm Happy Hamster V / 50 Hz

30 ULTRATHERM RADIANT PANELS ULTRATHERM radiant heating panels these panels utilise the principle of infrared radiation and are primarily intended for the localised heating and warming of breeding places, large terrariums or dog kennels. They are equipped with a thermal fuse which protects the panel from overheating. It is possible to install them in a vertical position; for horizontal installation it is necessary to order mounting frames. The standard colour is brown; white versions can be ordered and other colours are possible for an additional fee. TYPE [V] Coverage Dimensions [mm] Weight [kg] Quantity on pallet Panel ULTRATHERM 100 h ,5 Recommended height of installation Panel ULTRATHERM 200 h ,7 The apertures used for hanging the ULTRATHERM Panel ULTRATHERM 270 h IP ,2 panel are on the rear side of the panel. For the installation Panel ULTRATHERM 330 h ,6 of a panel in a horizontal position it is necessary to Panel ULTRATHERM 400 h ,9 order a ceiling frame Ceiling fi xing frame for the horizontal installation of ULTRATHERM 100 panels Ceiling fi xing frame for the horizontal installation of ULTRATHERM panels Ceiling fi xing frame for the horizontal installation of ULTRATHERM panels CERAMIC HEATING BULBS Ceramic heating bulbs heating bulbs (lamps) function on the principle of infra-red radiation they imitate the sun s heat radiation and thus create conditions close to those in the natural environment. Heating lamps have a standard screw base which fi ts normal plastic bulb holders; however, due to the higher operating temperatures involved, we defi nitely recommend using ceramic bulb holders. The range, intensity and direction of the heat current can be increased using an aluminium refl ector. Heating bulbs can be used to create different temperature zones within a terrarium. TYPE Output Voltage [V] 100 W ceramic heating bulb W ceramic heating bulb V / 50 Hz W ceramic heating bulb Ceramic bulb holder for the heating bulb AL refl ector for the heating bulb ULTRATHERM REGULATION Ultratherm Terra-Heat this thermostat is designed for the checking of air or soil temperature in a terrarium or vivarium. It is very simple to use and can be connected to any Ultratherm heating foil or heat strip, heating cable or mat, and also to other heaters available on the market with a maximum output of up to W. Description Settable temperature range 5 49 C; measured temperature range 5 49 C; accuracy: ±1 C; input wattage 230 V, 50 Hz

31 ECOFLEX convectors In convection heating, a heating body is used to warm the air which then distributes transfers - heat as it fl ows over the surfaces of the objects to be heated. Most electrical convector heaters that our fi rm distributes comes with a precise electronic thermostat, as standard, with a contact variation of +0.5 C. ECOFLEX EL electric convector with electronic thermostat and pilot wire, 4 5 C setback control, 230 V/50 Hz. Colour: white with gray grid. IP 24, class II; can be installed on C and D fl ammable surfaces; needed clearance (cm): bottom edge, 15 / top edge, 15 / front side, 10 IP 24 Type Dimmensions [mm] Weight [kg] Quantity on pallet ECOFLEX EL , ECOFLEX EL , ECOFLEX EL , ECOFLEX EL , ECOFLEX EL , ECOFLEX EL , ECOFLEX EL , ECOFLEX SL electric convector with electromechanical thermostat and pilot wire, 4 5 C setback control, 230 V/50 Hz. Colour: white with gray grid. IP 24, class II; can be installed on C and D fl ammable surfaces; needed clearance (cm): bottom edge, 15 / top edge, 15 / front side, 10 IP 24 Type Dimmensions [mm] Weight [kg] Quantity on pallet ECOFLEX SL , ECOFLEX SL , ECOFLEX SL , ECOFLEX SL , ECOFLEX SL , ECOFLEX SL , ECOFLEX SL , ECOFLEX SL ,

32 ELITE PLINTHE ETP electric convector with electronic thermostat and pilot wire, 4 5 C setback control, 230 V/50 Hz. Compatible with RF Box. Colour: white with white grid. IP 24, class II; needed clearance (cm): bottom edge, 8 / top edge, 20 / front side, 10 IP 24 Type Dimmensions [mm] Weight [kg] Quantity on pallet ELITE Plinthe ETP , ELITE Plinthe ETP , ELITE Plinthe ETP , ATLANTIC F 117-TAC electric convector with electronic (2500 W electromechanical) thermostat without pilot wire, for areas not requiring precise temperature regulation, such as stores and workshops. Colour: white with white grid. IP 24, class II; can be installed on C and D fl ammable surfaces; needed clearance (cm): bottom edge, 15 / top edge, 15 / front side, 15 IP 24 Type Dimmensions [mm] Weight [kg] Quantity on pallet ATLANTIC , ATLANTIC , ATLANTIC , ATLANTIC , ATLANTIC , ATLANTIC , ATLANTIC , ATLANTIC , ECOFLEX PREMIER radiant convector with electronic thermostat and pilot wire, 3.5 C setback control, 230 V/50 Hz. Colour: white with white grid. IP 24, class II; needed clearance (cm): bottom edge, 15 / top edge, 10 / front side, 100 IP 24 Type Dimmensions [mm] Weight [kg] Quantity on pallet ECOFLEX PREMIER , ECOFLEX PREMIER , ECOFLEX PREMIER , CH 2000 B TURBO portable convector with electromechanical thermostat IP 20, class I; needed clearance (cm): bottom edge, 5 / top edge, 10 / front side, 5 IP 20 Type Dimmensions [mm] Weight [kg] Quantity on pallet CH 2000B - TURBO 750/1250/ , RF BOX, ECOBOX FP wireless regulation and regulation for pilot wire By setting the thermostat regulations, it is possible to divide spaces into zones (ECOBOX FP: two zones, RF BOX: three zones) and to set a separate weekly program for each zone. Possibility of holiday setting to keep temperatures above freezing (at around 7 ºC) for a set numbers of days (1 99), after which the system automatically returns to its normal regime. Product Description RF transmitter RF receiver Pilot programmable unit for convector heating system. Wireless control (radio frequency) system: transmitter-receiver. Installation: wall or freely portable. Unit for receiving signal from RF transmitter. Receiver must be installed directly in the convector (Actua, Elite, Aixance) and must be in any convector that is to be controlled by an RF transmitter Ecobox FP Programmable unit for heating control transmitted over a pilot lead. ECOBOX FP should be installed on one of the convection heaters. The other convection heaters are connected to the main unit through the pilot wire and do not need additional equipment for receiving the signal

33 ECOFLEX G glass convector with electronic thermostat and pilot wire, 4 5 C setback control, 230 V/50 Hz. Available in black, red, or yellow-green. IP 24, class II; needed clearance (cm): bottom edge, 15 / top edge, 15 / front side, 15 IP 24 Type Dimmensions [mm] Weight [kg] Quantity on pallet ECOFLEX G X0 ECOFLEX G X2 ECOFLEX G X4 33

34 THERMOSTATS AND CONTROLS Product Description ANALOG ROOM THERMOSTAT FLASH A, bimetallic thermostat with signaling, without temperature setback, 5 35 C FLASH Same as a 25800, with temperature setback 3 7 K, invisible control, IP FLASH Same as a 25800, with temperature setback 3 7 K, accuracy 0.5 K, IP EBERLE RTR - E A, with temperature setback 5 K, accuracy 0.5 K, switch, 5 30 C EBERLE RTR - E A, with temperature setback 5 K, accuracy 0.5 K, 5 30 C FENIX-Therm A, IP 21, heat differential of 0.5 C, switch, C (ambient air), 5 50 C (fl oor) Frame for FENIX-Therm 100 Frame for use in wall mounting DIGITAL ROOM THERMOSTAT FENIX Therm 350 Programmable digital thermostat with Fuzzy-Logic (so-called Intelligent Thermostat) and three separate functions: room and fl oor thermostat, fl oor thermostat (factory set) or room thermostat; two preset programs, possible to use own settings. Each day can be set separately, four events per day. Air temp. range/fl oor range 5 37 C, 16 A, frost protection program, IP 21, power reserve 36 hours, 230 V; equipped with a LED dual function, switch on/off, lock, adaptive function and switch-on time (as a percentage for the last 24 hours, 7 days, 30 days or 365 days) EBERLE INSTAT 2 Programmable digital thermostat. Week divided into workdays and weekends, with four changes per day possible. Heating indicator on display, accuracy 0.5 K, 8 A, IP 30, air sensor 5 30 C EBERLE FIT 3U WATTS 760 WATTS 860 Programmable thermostat with PWM regulation or fi xed temperature difference. Operating modes fl oor only, room only, fl oor + room. 13 programmes 9 pre-set, 4 for users (4 temperature changes per day in 30 minute steps), holiday operation, permanent temperature or permanent attenuation modes, maintenance of a selected temperature for a set period. Temperature settable from 5 37 C in 0.5 C steps (fl oor and room). Option to set the max. and min. fl oor temperature, option of probe calibration. Technical parameters: 16 A switching contact, switch, key lock, back-lit display, automatic change to summer time. Floor probe is part of the package. Placement on KU 68. Lithium battery used for data back-up the fi rst charging must last at least 24 hours (formatting of the capacity of the battery). Programmable thermostat with Fuzzy-Logic option (so-called Intelligent Thermostat) or fi xed temperature difference (settable at C). Operation modes fl oor only, room only, fl oor + room. 5 preset + 2 user programmes - up to 12 temperature changes/day with the user programmes. Room temperature setting 5 37 C in 0.5 C steps. Option to set a max. and min. fl oor temperature. Setting of switched wattage for the exact correction of the room temperature, 16 A switching contact, holiday operation, permanent temperature mode, switch, key lock, display backlight, choice of two frames square, round. IP 21 coverage, placement on KU 68. The back-up of data is provided by a lithium battery the fi rst charging session must last at least 24 hours (it is for formatting the capacity of the battery). Weekly programme, selection of fl oor only, room only, fl oor+room modes, up to 9 temperature changes per day, PARTY mode short/term maintenance of a set temperature with an automatic return to the programme, HOLIDAY programme permanent attenuation for a set number of days with an automatic return to the programme, anti-freeze protection. Other functions: child lock, automatic change to summer time, operating hours counter (for the previous 2 days/week/year), option to limit manual temperature correction, setting of the min. and max. fl oor temperature, easy-to-read back-lit (blue) display with CZ menu, data and programme back-up for 10 years. Max. switched wattage is 2 kw. 4 m fl oor probe is part of the package. Placement on KU TH 810 T The outlet thermostat adjusts the outlet according to the set room temperature. Temperature range is 5 30 C (±1 C). Optional mode for cooling/heating.maximum switched current is 16 A (3,500 W). Maximum time for backed-up operation is 3 hours. Displays both set and current temperature in the room. Does not allow time programming VTM 3000 Selection of weekly or daily programme, selection of the modes fl oor only, room only, fl oor + room. 6 daily switching between the pre-set comfort and attenuation temperatures. Option to manually change the temperature with an automatic return to the programme. Other functions: permanent maintenance of comfort or attenuation temperatures, anti-freeze protection, permanent maintenance of manually set temperature (simulation of an analogue thermostat), setting of max. and min. fl oor temperature, operating hour counter. Data and programme back-up in the EEPROM memory (up to 10 years), time and date back-up with the help of a large-capacity capacitor period of back-up 6 hours. Technical parameters: switching contact 16 A / 230 V, max. switched wattage 2 kw, key lock, fl oor probe part of the package. Placement on KU TEMPERATURE REGULATORS FOR SUPPLEMENTAL UNDERFLOOR HEATING FENIX Therm 350 see Digital room thermostat (above) for details FENIX-Therm see Analog room thermostat (above) for details Frame for FENIX-Therm WATTS 760 see Digital room thermostat (above) for details WATTS 860 see Digital room thermostat (above) for details EBERLE FR E With fl oor sensor (4 m), C, 14 A, accuracy 1 K, IP 40, switch

35 Product Description EBERLE Fre With fl oor sensor (4 m), C, 10 A, with temperature setback, accuracy 1 K, IP 30, Switch Aube TH 132-AF Digital thermostat with fuzzy logic, ambient air sensor 5 30 C, fl oor (3 m) +5 C to +40 C, programming: 7 day, 4 time periods/day, 2 temperature settings, accuracy 0.5 K, IP Snubber AC EBERLE FIT 3U TEMPERATURE REGULATION FOR MAIN UNDERFLOOR HEATING The snubber must be connected into the circuit of the AUBE TH-132AF thermostat if the thermostat switches induction load (e.g. if the heating element is connected via a contactor). If the snubber isn t connected, spontaneous resetting of the thermostat may take place. The snubber should be connected as close as possible to the contactor, ideally directly to its contacts. Programmable thermostat with PWM regulation or fi xed temperature difference. Operating modes fl oor only, room only, fl oor + room. 13 programmes 9 pre-set, 4 for users (4 temperature changes per day in 30 minute steps), holiday operation, permanent temperature or permanent attenuation modes, maintenance of a selected temperature for a set period. Temperature settable from 5 37 C in 0.5 C steps (fl oor and room). Option to set the max. and min. fl oor temperature, option of probe calibration. Technical parameters: 16 A switching contact, switch, key lock, back-lit display, automatic change to summer time. Floor probe is part of the package. Placement on KU 68. Lithium battery used for data back-up the fi rst charging must last at least 24 hours (formatting of the capacity of the battery) FENIX Therm 350 Programmable digital thermostat with Fuzzy-Logic (so-called Intelligent Thermostat) and three separate functions: room and fl oor thermostat, fl oor thermostat (factory set) or room thermostat; two preset programs, possible to use own settings. Each day can be set separately, four events per day. Air temp. range/fl oor range 5 37 C, 16 A, frost protection program, IP 21, power reserve 36 hours, 230 V; equipped with a LED dual function, switch on/off, lock, adaptive function and switch-on time (as a percentage for the last 24 hours, 7 days, 30 days or 365 days) FENIX-Therm A, IP 21, heat differential of 0.5 C, switch, C (ambient air), 5 50 C (fl oor) Frame for FENIX-Therm 100 Frame for use in wall mounting Aube TH 132-AF see above for details Snubber AC see above for details EBERLE FIT 3U see above for details WIRELESS REGULATION SUITABLE FOR ECOSUN, MR AND GR PANELS BPT-SP wireless control unit transmitter SP1 wireless receiver fl ush-mounted SP2 wireless receiver wall-mounted SP3 wireless receiver socket 2 39 C, adjustable difference of switching C, PI-PWM, fuzzy logic, 9 select programmes, each programme up to six changes, option of differentiating between an odd and even week, 255 transmitters can be connected to different addresses, simple pairing receiver/transmitter, summer regime function, holiday, party, V AA power supply, placement on a wall or on a stand, range 35 m in buildings, up to 300 m in open areas, frequency MHz, option of control using a text message with the help of an additional GSM module, GST 1, (not included in the price). 16 A switches, 230 V power supply, IP20, receives information from BPT-SP and confi rms the change, frequency MHz, indication of operational status with LED diodes, connection in mounting box. 16 A switches, 230 V power supply, IP20, receives information from BPT-SP and confi rms the change, frequency MHz, indication of operational status with LED diodes, to be mounted on a wall or in mounting box. 16 A switches, 230 V power supply, IP20, receives information from BPT-SP and confi rms the change, frequency MHz, indication of operational status with LED diodes, insertion into a 230 V / 16 A socket PH-TS 20 programmable socket The PH-TS 20 socket is basically an SP3 receiver to which buttons, a display and a temperature sensor were added so that the socket can be programmed directly and the BPT-SP control unit is no longer needed for its operation. The PH-TS 20 programmable socket can also communicate wirelessly with the PH-CJ 37 SW central unit, and therefore it can also be included in the PocketHome central regulation system PH-CJ 37 SW central control unit The PH-CJ 37 SW central regulation unit is intended for the control of all BPT-SP units in the building. Using it creates a central regulation system for the whole building. The package also includes PocketHome software for the PC, a connecting cable for the PC s serial COM port and reduction to USB (RS232/USB convertor). The software enables the programming and control of the whole regulation system to be managed signifi - cantly better and more clearly than by using the buttons and display of the PH-CJ 37 SW central control unit GSM PH-GST 1 module The GSM module is used for the remote control of the Fenix BPT-SP control unit. With the help of text messages from your mobile phone, the temperature in the room can be regulated or the current state of the control unit can be ascertained. SIM card is not included in the price

36 Product Description INDUSTRIAL ROOM THERMOSTAT ANALOG WALL-MOUNTED THERMOSTATS WITH INCREASED PROTECTION (IP 54) EBERLE AZT - A Built-in space sensor and exterior scale. Ambient air sensor 5 35 C, 10 A, accuracy 1 5 K EBERLE AZT - A Built-in space sensor and exterior scale. Ambient air sensor C, 10 A, accuracy 1 5 K EBERLE AZT - I Built-in space sensor and interior scale. Ambient air sensor 5 35 C, 10 A, accuracy 1 5 K EBERLE AZT - I Built-in space sensor and interior scale. Ambient air sensor C, 10 A, accuracy 1 5 K INDUSTRIAL THERMOSTATS WITH SEPARATE SENSOR EBERLE UTR/60 16 A, exterior/interior control, temperature range 0 60 C, IP EBERLE ITR A, temperature range 0 60 C, exterior and interior control, suitable for mounting on DIN strip, IP EBERLE F Standard sensor, 4 m, PVC, IP EBERLE F Placement sensor for UTR and ITR, IP 64 coverage and silicon insulation, 1.5 m. EBERLE F Space sensor for UTR and ITR, IP 30, silicon insulation, 1.5 m. EBERLE F Space sensor without supply cable, IP 65. CONTROLLERS FOR GUTTERING AND OUTSIDE SURFACE HEATING Eberle EM (one-zone) Eberle EM (two-zone) Regulator for the heating of eaves troughs, downpipes and outdoor surfaces pavements and drives. In contrast with a manual or thermostatic controller it enables the achievement of operational cost savings of up to 80 %. Functions: setting of temperature and humidity, operating hours counter, alarm output, delayed switching off, current temperature indicator. Placement on a DIN strip (8 modules), CZ menu. The presence of humidity (water, snow or ice) and the outdoor temperature are monitored with the help of external sensors which need to be ordered separately for eaves troughs or free areas, depending on the application. A two-zone regulator for the heating of eaves troughs, downpipes and outdoor surfaces. The parameters and functions are the same as for the EM However, the regulator enables independent monitoring and control of two applications simultaneously. Basically, these are two EM regulators in one. Both zones require the connection of their own set of sensors for eaves troughs or free areas, depending on the application and these need to be ordered separately Set of EBERLE sensors for eaves troughs Humidity (ESD ) and temperature (TFD ) sensor for EM and EM regulators for controlling the heating of eaves troughs and downpipes Set of EBERLE ground sensors Humidity (ESF ) and temperature (TFF ) sensor for EM and EM regulators for controlling the heating of outdoor surfaces EBERLE DTR-E 3102 Differential thermostat, 230 V, 1 switching off / 1 switching contact 16 A, C, IP 65 (can be placed e.g. on the facade). While being operated it requires careful monitoring to attain economical operation OJ Electronik ETR/F-1447A Differential thermostat; 230 V, 1 switching contact 16 A, C, IP 20, on DIN rail (3 modules), room sensor (IP 44) included in the price. While being operated it requires careful monitoring to attain economical operation REGULATORS TO CONTROL ATTENUATION AND TIME PROGRAMMABLE SWITCHES FLASH Programmer 2 SED The regulator uses a pilot wire for switching between comfort and attenuation temperatures. There is the option to divide a building into two zones and set individual weekly programmes for each of them. A week is divided into 7 days; each day can be allocated one of three pre-set programmes or an individual programme can be created (different for each day). In the case of individual programming, a day is divided into 30-minute intervals. There is the option of holiday operation a temperature above freezing point (+7 C) is maintained for a period of 1 to 99 days, followed by a return to the programme mode. Outputs: sinusoid 230 V / 50 Hz, positive and negative half-wave, the potential of a neutral conductor for all types of convectors and thermostats. Dimensions mm, programme back-up 12 hours, IP 30 coverage. Placement on KU FLASH Monotron 200 Control device with weekly planning for full settings. One-minute min. setting interval, 250 V, switching 2 16 A, can be mounted on DIN strip REGULATORS FOR REDUCTION OF MAIN CIRCUIT BREAKER VALUE BMR HJ 101 One-level regulation with breaking for three phases, 1 3 A, current settings of 1 to 120 A with precision to 1 A. Two-level regulation with breaking for three phases, 2 3 A, current settings of 1 to 120 A with precision to 1 A. Three-level regulation with breaking for three phases, 3 3 A, current settings of 1 to 120 A with precision to 1 A. One-level regulation with separate breaking for individual phases, 3 3 A, current settings of 1 to 120 A with precision to 1 A, size 6 modules. Two-level regulation with separate breaking for individual phases, 6 3 A, current settings of 1 to 120 A with precision to 1 A, size 6 modules. Two-level regulation with indirect measuring, separate breaking for individual phases, 6 3 A, current setting from 4 to 1024 A in increments of 4 A BMR HJ BMR HJ BMR HJ Three-phase current-load reliever 6 modules. BMR HJ 306 BMR HJ

37 STORAGE HEATERS ECOSTATIC Static Storage Heater Basic Characteristics and Benefi ts Manually controlled electric storage heater Input and output adjustment according to the required comfort Attractively styled to suit modern home and offi ce decor Very low lifetime maintenance Safe, easily controllable and highly reliable Upgraded and adjusted for use in bathrooms (IP X2) IP 20 coverage; class I.; electromechanical thermostat for the limitation of charging + electromechanical thermostat for the control of discharging; * the WMX 706 type is without controlling thermostats; option of installation on a C or D fl ammable base; Needed clearance: side edges 75 mm, top edge 250 mm, front wall 300 mm IP X2 Type Input [kw] Max. capacity [kwh] Voltage [V] Dimmensions [mm] Weight [kg] WMX 706 * 0, WMX 712 1, ~ 50Hz WMX 718 2, WMX 724 3, ECODYNAMIC Dynamic Storage Heater Basic Characteristics and Benefi ts Electric fan storage heater with controllable heat output according to the Standards DIN 44574, IEC and the Safety Standard VDE 0720 Equipped with a thermomechanical charge controller (liquid fi lled) and a thermomechanical safety controller (bimetal) Airfl ow in two channels inside the core One brick type for all heater models (material: magnesite MgO) High-quality Vermiculite and Microtherm insulation (achieving lower surface temperatures and better heat accumulation) Only 25 cm deep No start-up procedure; may be operated by user immediately after installation Tube heating elements (special alloy steel) Radial fl ow fan for quiet and steady heat output Discharge controlled with an external room thermostat* Air outlet with bimetal fl ap system for high and constant heat output (automatic) Auxiliary heating element* installed in the air outlet area Sheet steel casing, phosphatized and enameled; colour: creme-white with gray-brown air outlet grill With a wall spacer and either supporting feet* or a fl oor plate* Protective cover* for bathrooms Storage bricks 2 Heating elements 3 Microtherm insulation 4 Charge controller 5 Bypass system 6 Wall bracket 7 Charge adjustment 8 Vermiculite insulation 9 Fan 10 Auxiliary heating element (optional) IP 20 coverage; class I.; electromechanical thermostat for the limitation of charging; option of installation on a C or D fl ammable base; Needed clearance: side and top edge 100 mm, front wall 300 mm IP X0 Type Input [kw] Max. capacity [kwh] Voltage [V] Dimmensions [mm] Weight [kg] VFMi 20 2, factory setting VFMi 30 3, N ~ 50Hz VFMi 40 4,0 32 may be changed VFMi 50 5,0 40 by a qualifi ed VFMi 60 6,0 48 technician to ~ 50Hz VFMi 70 7, * available on a special order 37

38 ATLANTIC Local heating not only provides you extra comfort, it also conserves electricity and water. Since these heaters are quite small, you can easily build one into a kitchen counter or the cabinet under the sink. Your kitchen s aesthetics can thereby be preserved. Principal characteristics and advantages Low-volume units heat water very close to the place where it is to be used. This eliminates the large losses typical of central hot water sources, where pipes leading from the central boiler sap the water s heat as they pass through walls. thermal insulation from polyurethane foam hot water outlet pipe enameled inner pressure tank exchangeable magnesium anode thermostat temperature sensor cold water inlet electrical heating element removable access fl ange thermostat electric water heater Type Capacity [l] Voltage [V] Input IP protection Heating time Net weight [kg] Height [mm] Diameter [mm] ATL 10 L IP 25 0h 24min ATL 10 LU IP 24 0h 19min ATL 15 L IP 25 0h 35min ATL 15 LU 15 IP 24 0h 28min ATL 30 L 30 0h 57min ATL 50 L 50 1h 30min ATL 80 L 80 2h 26min IP 25 ATL 100 L 100 3h 02min ATL 120 L 120 3h 35min ATL 150 L h 36min SUPPLEMENTARY PRODUCTS HAND DRYERS electric hot-air units with fans for hands drying. Wall-mountable. Automatic sensor switch ensures hygienic operation. ZY A (metal) Type Output Switching sensor Air temperature Tension Dimension [mm] Weight [kg] ZY A (plastic) 1800 W cm C ~ 230 V , ZY A (metal) 2700 W cm C 50 Hz , ZY A (plastic) ELECTRIC TOWEL DRYERS are intended mainly for use in bathrooms, washrooms, showers or kitchens for the drying of damp towels, bath towels, tea towels etc. The installation is simple the dryer is attached to the wall using three plastic grips and the supply lead is connected to a standard socket. The heating element is protected from overheating by a thermal fuse; the element doesn t contain any fi lling and therefore there is no danger of freezing, air intake or leakage of the liquid. TUBULAR HEATING ELEMENTS with an electric heating insert. Intended primarily for bathrooms suitable for drying bath towels, hand towels etc. IP 65 coverage. Voltage 230 V / 50 Hz. White RAL 9016; fi lled with non-freezing mixture, 1 m coiled connection cable (extends to 3,5 m) with plug. Mounting brackets are included with the product. The heating element is without a thermostat. It can be combined with a TH 810 T plug in thermostat. Type K-E fl at Wattage Width [mm] Height [mm] Depth [mm] Weight [kg] Output 100 W, voltage 230 V / 50 Hz, IP 44 coverage, insulation class I., switch with a light which signals operation, 1.6 m long straight supply cable with a plug. Type Colour Width [mm] Height [mm] Depth [mm] Weight [kg] STR - W white ,9 STR - CR chrome K-E , K-E , K-E , K-E , K-E , KDO-E rounded KDO-E , KDO-E , KDO-E , KDO-E , KDO-E ,

39 EXPORT MARKETS Argentina Armenia Australia Austria Belorussia Benelux Bosnia and Herzegovina Brazil Bulgaria Canada Columbia Croatia Cyprus Czech Republic Denmark Estonia Finland France Georgia Germany Great Britain Greece Hungary Chile Iran Ireland Italy Japan Korea Kazakhstan Kingdom of Jordan Latvia Lithuania Macedonia Malta Montenegro Netherlands New Zealand Norway Poland Portugal Romania Russia Serbia Slovakia Slovenia Spain Sweden Switzerland Syria Turkey Ukraine Uruguay USA

40 HEADQUARTER FENIX GROUP a.s. Šárecka 37, Praha 6, Czech Republic; FENIX TRADING s.r.o. Slezská 2, Jeseník, Czech Republic; Tel.: , ; Fax: ; PRODUCTION PLANT FENIX s.r.o., Jaroslava Ježka 1338/18a Jeseník, Czech Republic BRANCH STORE FENIX BOHEMIA Vejvanov 17, Radnice Czech Republic FLEXEL EL INTERNATIONAL LTD. Glenrothes, Fife, Scotland exel.co.uk exel.co.uk FENIX SLOVENSKO s.r.o. Iliašská cesta Bánská Bystrica, Slovakia CEILHITIT Camino de la Riereta, L Hospitalet de Llobregat (Barcelona), Spain comercial@ceilhit.es ACSO 11 bis, boulevard carnot Labastide-Rouairoux, France acso@acso.fr FENIX TRADING s.r.o. Slezská 2, Jeseník, Czech Republic; Tel.: , ; Fax: ; fenix@fenixgroup.cz

Product catalogue April 2017

Product catalogue April 2017 Product catalogue April 2017 Fenix was founded in 1990 as one of the first private companies in the Czech Republic following the Velvet Revolution. The first items produced were the successfully marketed

More information

Product catalogue October 2017

Product catalogue October 2017 Product catalogue October 2017 Fenix was founded in 1990 as one of the first private companies in the Czech Republic following the Velvet Revolution. The first items produced were the successfully marketed

More information

Product catalogue April 2008

Product catalogue April 2008 Product catalogue April 2008 ELECTRIC HEATING complete solution for your home ECOSUN radiant heating panels pages 4 7 low and high temperature radiant ceiling panels marble and glass radiant panels for

More information

Product catalogue April 2018

Product catalogue April 2018 Product catalogue April 2018 Fenix was founded in 1990 as one of the first private companies in the Czech Republic following the Velvet Revolution. The first items produced were the successfully marketed

More information

ELECTRIC HEATING. complete solution for your home

ELECTRIC HEATING. complete solution for your home Product catalogue ELECTRIC HEATING complete solution for your home ECOSUN radiant heating panels pages 4 7 low and high temperature radiant ceiling panels marble and glass radiant panels for residential,

More information

P R O D U C T C A T A L O G U E. Only the sun does it better...

P R O D U C T C A T A L O G U E. Only the sun does it better... P R O D U C T C A T A L O G U E Only the sun does it better... 1 Fenix was founded in 1990 as one of the first private companies in the Czech Republic following the Velvet Revolution. The first items produced

More information

UNDERWOOD HEATING SYSTEM

UNDERWOOD HEATING SYSTEM INSTALLATION MANUAL Suitable for most wooden/laminate fl oors (always check with fl oor manufacturer) Ideal for most wood/laminate fl oors Easy to install Fully compliant to latest regulations CE approved

More information

WARRANTY INSTALLATION MANUAL. Ideal for most wood/ laminate fl oors Easy to install. Fully compliant to latest regulations CE approved

WARRANTY INSTALLATION MANUAL. Ideal for most wood/ laminate fl oors Easy to install. Fully compliant to latest regulations CE approved INSTALLATION MANUAL LIFETIME WARRANTY Ideal for most wood/ laminate fl oors Easy to install Fully compliant to latest regulations CE approved Suitable for most wooden/laminate fl oors (always check with

More information

protection Constant wattage heating cables Self-regulating heating cables Temperature controllers

protection Constant wattage heating cables Self-regulating heating cables Temperature controllers snow & ice protection Constant wattage heating cables Self-regulating heating cables Temperature controllers Protection of roofs, gutters and downpipes Snow and ice protection systems protect against:

More information

GENERAL CATALOGUE Only the sun does it better...

GENERAL CATALOGUE Only the sun does it better... GENERAL CATALOGUE Only the sun does it better... 1 Fenix was founded in 1990 as one of the first private companies in the Czech Republic following the Velvet Revolution. The first items produced were the

More information

WARRANTY INSTALLATION MANUAL. Ideal for most wood/ laminate fl oors Easy to install. Fully compliant to latest regulations CE approved

WARRANTY INSTALLATION MANUAL. Ideal for most wood/ laminate fl oors Easy to install. Fully compliant to latest regulations CE approved INSTALLATION MANUAL LIFETIME WARRANTY Ideal for most wood/ laminate fl oors Easy to install Fully compliant to latest regulations CE approved Suitable for most wooden/laminate fl oors (always check with

More information

DOMOTHERM CLASSIC TWIN/S MAT

DOMOTHERM CLASSIC TWIN/S MAT Floor warming products 2013 V 10.12.2012 DOMOTHERM CLASSIC TWIN/S MAT An ideal solution for the whole house Ultra thin cable (2mm) Energy efficient Easy to install Domotherm Twin/s can be installed under:

More information

CERTIFIED UNDERFLOOR HEATING WITH 15 YEARS GUARANTEE

CERTIFIED UNDERFLOOR HEATING WITH 15 YEARS GUARANTEE Electric underfloor heating Simple to install Cheap to install Simple to regulate Safe to use Maintenance free CERTIFIED UNDERFLOOR HEATING WITH 15 YEARS GUARANTEE WHY CHOOSE HEATCOM? Heatcom is a leading

More information

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes WARM WATER UNDERFLOOR HEATING SYSTEMS Guidance Notes 02 WARM WATER UNDERFLOOR HEATING SYSTEMS Introduction Underfloor heating systems consist of a series of pipes which are integrated into the floor structure

More information

UNDERFLOOR HEATING SYSTEMS ECOFILM SET ECOFLOOR ECOFLEX. underfloor heating cable. underfloor heating mat. underfloor heating element

UNDERFLOOR HEATING SYSTEMS ECOFILM SET ECOFLOOR ECOFLEX. underfloor heating cable. underfloor heating mat. underfloor heating element UNDERFLOOR HEATING SYSTEMS ECOFILM SET underfloor heating element ECOFLOOR underfloor heating mat ECOFLEX underfloor heating cable Enhance the beauty of a wood floor Simple to install - A Completely dry

More information

EN-SUITE & KITCHEN HEATING

EN-SUITE & KITCHEN HEATING EN-SUITE & KITCHEN HEATING 64 ELECTRIC UNDER FLOOR HEATING 70 HEATED TOWEL RADIATORS 74 MIRROR DEMISTERS ELECTRIC UNDERFLOOR HEATING Electric Under Floor Heating It s like walking on Sunshine Comfort electric

More information

Anti frost. Snow Melting USA 2012 USA 2014

Anti frost. Snow Melting USA 2012 USA 2014 Anti frost USA 2014 USA 2012 1 Mat Resistance Wires Reinforced Braide PVC Jacketing Super strong aramid FEP Mat DomoTecK s Mat is the ideal heating element for outdoor de-icing. Our snow melting mat prevents

More information

LIFETIME. INSTALLATION MANUAL emat Pro 100w/150w/200w WARRANTY

LIFETIME. INSTALLATION MANUAL emat Pro 100w/150w/200w WARRANTY INSTALLATION MANUAL emat Pro 100w/150w/200w LIFETIME WARRANTY Before you begin installing, read through these instructions carefully and check that you have all the components required. 01473 276677 www.elementsunderfloorheating.co.uk

More information

4 1 Heating. wooden floors or renovated floors.

4 1 Heating. wooden floors or renovated floors. 4 1 Heating 1.1 General information DEVI s floor heating systems consist of deviflex heating cables or devimat heating mats, devireg temperature regulation thermostats, and installation accessories. The

More information

electric floor heating for everyone Heating mats Heating cables Temperature controllers

electric floor heating for everyone Heating mats Heating cables Temperature controllers electric floor heating Heating mats solutions for everyone Heating cables Temperature controllers Floor heating as the most favourable heating solution Of all heating systems, floor heating s vertical

More information

electric floor heating Heating mats Heating cables Temperature controllers

electric floor heating Heating mats Heating cables Temperature controllers electric floor heating Heating mats Heating cables Temperature controllers Floor heating as the most favourable heating solution Of all heating systems, floor heating s vertical temperature distribution

More information

electric floor heating Heating mats Heating cables Temperature controllers

electric floor heating Heating mats Heating cables Temperature controllers electric floor heating Heating mats Heating cables Temperature controllers Floor heating as the most favourable heating solution Of all heating systems, floor heating s vertical temperature distribution

More information

Carbon Film Installation Instructions

Carbon Film Installation Instructions Contents Page 2 Page 3 Page 4 Page 5 Page 8 Product Overview Pre-Installation & Electrical Provision Depron Underlay Installation Carbon Film Installation - Under Wood/Laminate Flooring Notes & Trouble

More information

Installation And User Instructions. Devimat Warm Floor System Installation Instructions User Guide Trouble Shooter

Installation And User Instructions. Devimat Warm Floor System Installation Instructions User Guide Trouble Shooter GB Installation And User Instructions Devimat Warm Floor System Installation Instructions User Guide Trouble Shooter 1 Existing Floor Wooden Floors Concrete Floors Maximum load per m 2 100 W/m 2 150 W/m

More information

emat Pro 100/150/200 Installation Manual

emat Pro 100/150/200 Installation Manual emat Pro 100/150/200 Installation Manual www.electricunderfloorheating.co.uk Before you begin installing read through these instructions carefully and check that you have all the components required. Introduction

More information

Discover the diversity of thermofer

Discover the diversity of thermofer Discover the diversity of thermofer ENERGY-SAVING & FLEXIBLE PANEL HEATING cosy economic environmentally friendly future-proof 50% Energy saving compared to todays traditional gas based heating systems

More information

CASE STUDY UNDER FLOOR HEATING. Electric Underfloor Heating Display Stand

CASE STUDY UNDER FLOOR HEATING. Electric Underfloor Heating Display Stand CASE STUDY UNDER FLOOR HEATING Electric Underfloor Heating Display Stand 58 & MIRROR DEMISTERS 60 BENEFITS & FEATURES OF UFH 64 THERMOSTATS 62 THERMAL INSULATION BOARD 66 MIRROR DEMISTERS 63 HEATING MATS

More information

Toll Free:

Toll Free: 1 ProLine s electric radiant floor heating system is one of the most popular and durable floor heating solutions on the market. Available pre-spaced in mats with an adhesive backing or on the spool, the

More information

Polymer solutions Heating mat EM2-CM

Polymer solutions Heating mat EM2-CM 1.5 Polymer solutions 1. Application EM2-CM is a constant wattage heating mat for simple, fast, and effective ramp and accessway heating to prevent snow and ice formation. The EM2-CM mat is particularly

More information

Installation And User Instructions. devimat Warm Floor System Installation Instructions User Guide Trouble Shooter

Installation And User Instructions. devimat Warm Floor System Installation Instructions User Guide Trouble Shooter GB Installation And User Instructions devimat Warm Floor System Installation Instructions User Guide Trouble Shooter Existing Floor Wooden Floors Concrete Floors Maximum load per m 2 100 W/m 2 150 W/m

More information

INSTRUCTION. Danfoss heating cable mats type 100/150 Danfoss heating cable mats for thin floors. Danfoss heating cable mat type 100/150

INSTRUCTION. Danfoss heating cable mats type 100/150 Danfoss heating cable mats for thin floors. Danfoss heating cable mat type 100/150 INSTRUCTION GB Danfoss heating cable mats type 100/150 Danfoss heating cable mats for thin floors NB! Read page 2 before installing the product if you intend to connect 2 mats to the same thermostat Danfoss

More information

Introduction. Please read the following instructions carefully before commencing installation.

Introduction. Please read the following instructions carefully before commencing installation. Introduction Please read the following instructions carefully before commencing installation. Installation involves simple processes. These are explained step by step in the following pages. Should you

More information

CoziMat. 1. Introduction and Brief Description COZIMAT INSTALLATION INSTRUCTIONS & SAFETY REQUIREMENTS

CoziMat. 1. Introduction and Brief Description COZIMAT INSTALLATION INSTRUCTIONS & SAFETY REQUIREMENTS CoziMat 1. Introduction and Brief Description The CoziMat underfloor heating mat is designed for underfloor heating of rooms where the floor thickness needs to be kept to a minimum. CoziMat underfloor

More information

Underfloor Heating Mat Installation Manual

Underfloor Heating Mat Installation Manual Affordable Underfloor Heating Underfloor Heating Mat Installation Manual Technical Helpline 0845 034 8272 www.sunstone.co.uk 1 SunStone Mat Manual V3.1.indd 1 09/01/2015 13:58:26 DO S & DON TS ENSURE CORRECT

More information

LIFETIME. INSTALLATION MANUAL efoil WARRANTY

LIFETIME. INSTALLATION MANUAL efoil WARRANTY INSTALLATION MANUAL efoil LIFETIME WARRANTY Before you begin installing, read through these instructions carefully and check that you have all the components required. 01473 276677 www.elementsunderfloorheating.co.uk

More information

radiant floor heating Floor Heating Mats Floor Heating Cables Thermostats

radiant floor heating Floor Heating Mats Floor Heating Cables Thermostats radiant floor heating Floor Heating Mats Floor Heating Cables Thermostats Radiant floor heating: A modern comfort solution Floor heating s vertical temperature distribution is the closest form of heating

More information

Electrical Heating Solutions. Energy efficient building technology

Electrical Heating Solutions. Energy efficient building technology Electrical Heating Solutions Energy efficient building technology Tassu and Tassu S underfloor heating cables Tassu and Tassu S are maintenance-free products for long-term solutions in dry and damp areas.

More information

Underfloor Heating Cable Installation Manual

Underfloor Heating Cable Installation Manual Affordable Underfloor Heating Underfloor Heating Cable Installation Manual Technical Helpline 0845 034 8272 www.sunstone.co.uk SunStone Wire Manual V3.1.indd 1 09/01/2015 14:00:49 BEFORE YOU BEGIN INSTALLATION...

More information

IRH-INFRARED-HEATING-SYSTEMS GmbH

IRH-INFRARED-HEATING-SYSTEMS GmbH PRODUCT CATALOGUE 2017 IRH-INFRARED-HEATING-SYSTEMS GmbH IT IS OUR PLEASURE, TO OFFER YOU ONE OF THE LARGEST CHOICES IN INFRARED HEATING AND CONTROL SYTEMS AVAILABLE Table of contents IRH product lines...

More information

Underwood Heater Installation Manual

Underwood Heater Installation Manual Underwood Heater Installation Manual Contents Important Safeguards and Warnings... 3 1 General Information... 3 1.1 Use of the Manual... 3 1.2 Safety Guidelines... 3 1.3 Remember to measure resistance...

More information

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10 MAKING MODERN LIVING POSSIBLE Installation Guide SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10 www.eh.danfoss.com Table of Contents 1 Introduction............................................. 3 1.1 Self-limiting

More information

Always make sure to check the heating film before, during, and after installation of the floor covering.

Always make sure to check the heating film before, during, and after installation of the floor covering. Installation of floor heating film for ceramic tiles, granite and other stone or composite flooring Read through this entire manual before starting installation. All electrical connections must be made

More information

FLEXEL RADIANT HEATING SYSTEMS

FLEXEL RADIANT HEATING SYSTEMS THE COMPLETE PRICE GUIDE FLEXEL RADIANT HEATING SYSTEMS RADIANT HEATING PANELS Domestic Radiant Heating Commercial Radiant Heating Church Radiant Heating www.flexel.co.uk Contents DOMESTIC ECOSUN UB -

More information

F1202 TRACE HEATING. Road & Ramp

F1202 TRACE HEATING. Road & Ramp Trace Heating Specialists Road & Ramp ROAD & RAMP HEATING ESH Trace Heating Ltd provide a comprehensive range of products to prevent the settlement of snow and formation of ice on roads, ramps and stairs.

More information

IMPORTANT NOTES. Electric Underfloor Heating Mats For use with Touchsceen underfloor heating Thermostat

IMPORTANT NOTES. Electric Underfloor Heating Mats For use with Touchsceen underfloor heating Thermostat For any assistance or further information, go online at bathstore.com Electric Underfloor Heating Mats For use with Touchsceen underfloor heating Thermostat - 61000012339 Model Dimensions Area Covered

More information

PENDER Vario. PENDER Vario Line. PENDER Profi Line. PENDER Air Curtains. PENDER Airquell. Exhaust Technology.

PENDER Vario. PENDER Vario Line. PENDER Profi Line. PENDER Air Curtains. PENDER Airquell. Exhaust Technology. PENDER Vario PENDER Vario Line PENDER Profi Line PENDER Air Curtains PENDER Airquell Exhaust Technology www.pender.de Our company Your manufacturer of trend-setting and efficient hall heating systems Your

More information

OneZone. Underfloor heating range. For existing properties & new build extensions. Extensions Conservatories Single rooms HEAT PUMPS

OneZone. Underfloor heating range. For existing properties & new build extensions. Extensions Conservatories Single rooms HEAT PUMPS Extensions Conservatories Single rooms OneZone Underfloor heating range For existing properties & new build extensions UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL Contents Warm water underfloor heating

More information

Installation And User Instructions GB/IRE. Devimat Warm Floor System Installation Instructions User Guide Trouble Shooter

Installation And User Instructions GB/IRE. Devimat Warm Floor System Installation Instructions User Guide Trouble Shooter GB/IRE Installation And User Instructions Devimat Warm Floor System Installation Instructions User Guide Trouble Shooter Please retain this booklet for homeowners future reference. For Devireg 55 setup

More information

Installation Instruction

Installation Instruction GB/DAS Installation Instruction Devimat DTIF 100/150 Heating cable mats for thin floors NB! Read page 3 before installing the product if you intend to connect 2 mats to the same thermostat 1 Devimat 100/150

More information

Electric Warm-Stretch under floor heating

Electric Warm-Stretch under floor heating Electric Warm-Stretch under floor heating bath store Installation Manual Please read these instructions before you start your installation. Any damage to the system due to incorrect installation will invalidate

More information

Simple. Smart. Solutions. ROOM PACK Z2105/239/0812. Step by Step Installation Guide

Simple. Smart. Solutions. ROOM PACK Z2105/239/0812. Step by Step Installation Guide Simple. Smart. Solutions. ROOM PACK Z2105/239/0812 Step by Step Installation Guide 1. Room Pack Overview 2. Temperature Settings 3. Operation 4. Wiring 5. Installing Your Room Pack Before you get started

More information

THE NEW ERA IN HEATING

THE NEW ERA IN HEATING THE NEW ERA IN HEATING MIRRORS AND TOWEL RAILS COVERED OUTDOOR INFRARED HEATERS WHAT IS INFRARED AND HOW DOES IT WORK? DESIGNER GLASS SERIES INFRARED COMMERCIAL CEILING PANELS CUSTOMISABLE ALUMINIUM PANELS

More information

Electric Under Floor Heating

Electric Under Floor Heating Electric Under Floor Heating It s like walking on Sunshine Comfort electric underfloor heating provides a very comfortable, efficient and economical addition or alternative to standard heating systems.

More information

Installation Guide. Heating cables. Thin concrete (< 3 cm) Intelligent solutions with lasting effect. Visit DEVI.com

Installation Guide. Heating cables. Thin concrete (< 3 cm) Intelligent solutions with lasting effect. Visit DEVI.com Installation Guide Heating cables Thin concrete (< 3 cm) Intelligent solutions with lasting effect Visit DEVI.com Table of contents 1 Introduction.................... 2 1.1 Safety Instructions...............2

More information

FLOOR WARMING PRODUCTS. For more ALL PICTURES & GRAPHICS ARE FOR ILLUSTRATION ONLY

FLOOR WARMING PRODUCTS. For more ALL PICTURES & GRAPHICS ARE FOR ILLUSTRATION ONLY 3102 A very warm welcome to The Decora Group the management and holding company for Domoteck and Climateck Industries. Focusing on making modern living comfortable, the Decora group has developed some

More information

Model Dimensions Coverage 230v 230Vac. Pack Contents. Measuring Up

Model Dimensions Coverage 230v 230Vac. Pack Contents. Measuring Up Installation and Operating Instructions Electric tile-warming system Model Dimensions Coverage Wattage @ 230v Amps@ 230Vac RTS1M 2.0m x 0.5m 1.0m 2 160W 0.70A RTS1.5M 3.0m x 0.5m 1.5m 2 240W 1.04A RTS2M

More information

INSTALLATION INSTRUCTIONS TD75. Vented tumble dryer DOMESTIC. Carefully read the instructions for use before using the dryer.

INSTALLATION INSTRUCTIONS TD75. Vented tumble dryer DOMESTIC. Carefully read the instructions for use before using the dryer. INSTALLATION INSTRUCTIONS TD75 Vented tumble dryer DOMESTIC Carefully read the instructions for use before using the dryer. Dear Customer, Read these instructions carefully and completely before you install

More information

Installing Underfloor Heating Film. 1. Layout of electric underfloor heating systems

Installing Underfloor Heating Film. 1. Layout of electric underfloor heating systems Read through this entire manual before starting installation. May be installed under laminate, engineered wood or approved hardwood floors. See flooring manufacturer s specifications and instructions.

More information

Undertile Heating Mat. Instructions. CORGI Underfloor Heating - Quality, Flexibility, Safety 1

Undertile Heating Mat. Instructions. CORGI Underfloor Heating - Quality, Flexibility, Safety 1 Undertile Heating Mat Instructions CORGI Underfloor Heating - Quality, Flexibility, Safety 1 It is vital that you read through these instructions fully before installing your CORGI undertile heating mat.

More information

Aquience 1200/1500 R

Aquience 1200/1500 R Aquience 1200/1500 R Congratulations, you have purchased one of the fi nest quality aquariums available. This product will give you many years of excellent service when installed and maintained correctly.

More information

FIRST Heating. Company and product overview

FIRST Heating. Company and product overview FIRST Heating Company and product overview 1 Introductions to group companies FIRST Heating is 100% owned by investment group profit park.cz, s.r.o. FIRST Heating is part of a group of companies with international

More information

HEATXL RVS. Electric Infrared Heater

HEATXL RVS. Electric Infrared Heater HEATXL RVS Electric Infrared Heater HeatXL RVS Heater is an all-round, supplementary or overall heater for conservatories, balconies, patios and is also effective as a spot/zone heater in workshops, warehouses

More information

THE COMPLETE PRICE GUIDE FLEXEL

THE COMPLETE PRICE GUIDE FLEXEL THE COMPLETE PRICE GUIDE FLEXEL INFRARED HEATING SYSTEMS INFRARED HEATING PANELS Domestic Heating Commercial Heating Church Heating www.flexel.co.uk Table of Contents DOMESTIC INFRARED PANELS ECOSUN UB

More information

Installation Manual. Electric Underfloor Heating. heatingthroughinnovation.

Installation Manual. Electric Underfloor Heating. heatingthroughinnovation. Installation Manual Electric Underfloor Heating heatingthroughinnovation. 02 Electric Underfloor Heating Contents 1.0 General Information 03 2.0 Preparation 04 3.0 Installation 05 4.0 Measuring Values

More information

INSTRUCTION MANUAL FOR ELECTRIC RADIANT INFRARED HEATERS

INSTRUCTION MANUAL FOR ELECTRIC RADIANT INFRARED HEATERS www.colorato.net INSTRUCTION MANUAL FOR ELECTRIC RADIANT INFRARED HEATERS MODELS: CLHR-150A / CLHR-180A / CLHR-240A / CLHR-320A Read carefully this manual before using the appliance and keep them for future

More information

FLEXEL RADIANT HEATING SYSTEMS

FLEXEL RADIANT HEATING SYSTEMS THE COMPLETE PRICE GUIDE FLEXEL RADIANT HEATING SYSTEMS RADIANT HEATING PANELS Domestic Radiant Heating Commercial Radiant Heating Church Radiant Heating www.flexel.co.uk Contents DOMESTIC ECOSUN UB -

More information

floor heating system

floor heating system floor heating system Installation manual Instrukcja montażu Инструкция по установке EN PL RU EN The package contains: Thin self-adhesive heating mat Thermostat and temperature sensor (option) Installation

More information

ELECTRIC HEATING THERMOSYSTEM

ELECTRIC HEATING THERMOSYSTEM ELECTRIC RADIANT MAT 8200E INSTALLATION AND USE MANUAL heating passion ELECTRIC HEATING THERMOSYSTEM WARNING: For the guarantee to be valid, the product must be installed and handled as indicated in this

More information

Installation Manual SPA BROADWAY MAXI

Installation Manual SPA BROADWAY MAXI Installation Manual SPA BROADWAY MAXI 1 2 INDICE 1. RECEIVING THE EQUIPMENT... 4 2. PREPARING THE PLACE FOR THE INSTALLATION... 4 3. POSITIONING THE SPA... 7 4. ELECTRICAL CONNECTIONS... 7 4.1. Earth connection...

More information

BACE cm ceramic electric cooktop GECE cm ceramic electric cooktop

BACE cm ceramic electric cooktop GECE cm ceramic electric cooktop BACE9004 90cm ceramic electric cooktop GECE9004 90cm ceramic electric cooktop 1 BHI609 60cm Front touch control induction zone hob 2 User Manual for your BACE9004 GECE9004 90 cm Front touch control 4 radiant

More information

THE HEATING YOUR POCKET WILL LOVE. Rointe. Heating solutions.

THE HEATING YOUR POCKET WILL LOVE. Rointe. Heating solutions. r e v o c s i D THE HEATING YOUR POCKET WILL LOVE Rointe Heating solutions www.rointe.co.uk W W I TH i-f i COMMITTED TO YOU and your customers. COMPLETE 1 HEATING SYSTEM UNDER SINGLE CONTROL MEETS WITH

More information

Uponor Comfort E AL-Foil Mat

Uponor Comfort E AL-Foil Mat Uponor Comfort E AL-Foil Mat Contents Important notes on the intended use, safety and warranty...3 Intended use...3 Uponor Declaration of Warranty...3 System description...4 Floor construction...4 Technical

More information

amuheat Cable Mat floor heating systems Installation Manual CM02-12

amuheat Cable Mat floor heating systems Installation Manual CM02-12 amuheat floor heating systems Cable Mat Installation Manual CM02-12 Table of Contents Introduction 1 2 Cable Mat Important Installation Guidelines Tools & Materials Needed for Installation Kit Contents

More information

PRODUCT CATALOGUE 2017

PRODUCT CATALOGUE 2017 PRODUCT CATALOGUE 2017 IRH-INFRARED-HEATING-SYSTEMS GmbH IT IS OUR PLEASURE, TO OFFER YOU ONE OF THE LARGEST CHOICES IN INFRARED HEATING AND CONTROL SYTEMS AVAILABLE Table of contents IRH product lines...

More information

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Contact Details. Please note that some of the contact details on this PDF document may not be current. Contact Details Please note that some of the contact details on this PDF document may not be current. Please use the following details if you need to contact us: Telephone: 0844 879 3588 Email: customer.services@gdcgroup.co.uk

More information

Installation & Service Manual. Models ALF 20, 30, 40, 50, 60, 80

Installation & Service Manual. Models ALF 20, 30, 40, 50, 60, 80 Installation & Service Manual Models ALF 20, 30, 40, 50, 60, 80 IMPORTANT! Read all safety instructions before installing, using, or servicing the heater. Installation & servicing should only be carried

More information

ECOLEC PANEL HEATERS GENERAL NOTES.

ECOLEC PANEL HEATERS GENERAL NOTES. GENERAL NOTES. ECOLEC heating products are specifically designed to give you comfortable, controllable warmth when and where you need it. PLEASE READ THESE NOTES BEFORE INSTALLATION AND RETAIN FOR FUTURE

More information

SAUNA BARREL 3.0 m, Ø Plans: with and without terrace

SAUNA BARREL 3.0 m, Ø Plans: with and without terrace SAUNA BARREL 3.0 m, Ø 2.27 Plans: with and without terrace SPECIFICATION STANDARD SET Sauna Sauna barrel Length of the barrel, m 3.00 Stainless steel tightening bands Diameter, m 2.27 Roof covered with

More information

Installation manual SP3

Installation manual SP3 Installation manual SP3 INTRODUCTION This installation manual is made for all parties involved in installing Parans solar lighting. It deals with planning and installing the Parans solar lighting system.

More information

ELEKTRA HEATING MATS. Designed to be installed under laminate flooring and/or engineered wood UK PL RU. Installation manual

ELEKTRA HEATING MATS. Designed to be installed under laminate flooring and/or engineered wood UK PL RU.   Installation manual www.elektra.eu ELEKTRA HEATING MATS Designed to be installed under laminate flooring and/or engineered wood Installation manual Instrukcja montażu Èíñòðóêöèÿ ïî ìîíòàæó UK PL RU Purpose The ELEKTRA WoodTec

More information

User Manual. 60 cm Knob control 4 zone ceramic cooktop

User Manual. 60 cm Knob control 4 zone ceramic cooktop User Manual HHC601 60 cm Knob control 4 zone ceramic cooktop OTE: This User Instruction Manual contains important information, including safety & installation points, which will enable you to get the most

More information

HEAT CABLE underfloor heating

HEAT CABLE underfloor heating HEAT CABLE underfloor heating Installation Manual Thermosoft Heat Cable Installation Manual Page 1 INSTALLATION INSTRUCTIONS TM u n d e r f l o o r h e a t i n g c a b l e Please read these notes carefully

More information

Installation And User Instructions

Installation And User Instructions GB Installation And User Instructions Devimat Warm Floor System Installation Instructions User Guide Trouble Shooter 1 Existing Floor Maximum load per m 2 Wooden Floors 100 W/m 2 Concrete Floors 150 W/m

More information

Underlaminate Foil Heater

Underlaminate Foil Heater Installation Manual: Underlaminate Foil Heater TECHNICAL HELPLINE 0845 345 2288 n online at warmup.co.uk IMPORTANT Read this manual before attempting to install your foil heater. Incorrect installation

More information

Floor Heating & Heated Towel Rails Product Catalogue

Floor Heating & Heated Towel Rails Product Catalogue Floor Heating & Heated Towel Rails Product Catalogue Affordable Heating Luxuries HEATING 1300 HOTWIRE hotwireheating.com.au Hotwire Floor Heating Hotwire Floor Heating may well be the very ultimate in

More information

UNDERFLOOR HEATING GUIDE

UNDERFLOOR HEATING GUIDE UNDERFLOOR HEATING GUIDE Bringing you the best underfloor heating in South Australia for 30 years. Introduction to Underfloor Heating Due to its supreme level of comfort and great heating efficiency, underfloor

More information

Installation instructions for condenser tumble dryer DOMESTIC. Dear Customer,

Installation instructions for condenser tumble dryer DOMESTIC. Dear Customer, Dear Customer, Read these instructions carefully and completely before you install the machine. The installation should be carried out by a qualified person who is familiar with all local codes and ordinances

More information

UNDERFLOOR HEATING EXPRESS. UK s Water & Electric Underfloor Heating Supplier

UNDERFLOOR HEATING EXPRESS. UK s Water & Electric Underfloor Heating Supplier UK s Water & Electric Underfloor Heating Supplier CATALOGUE 2017 Electric Underfloor Heating Water Underfloor Heating Manifolds & Pumps Insulation Boards Thermostats & Controls Accessories Underfloor Heating

More information

Convector Heater G2CH. 2.0kW. 3 Power settings. Fully adjustable thermostat. Wall mounting option. Illuminated control switch. Fitted with 1.

Convector Heater G2CH. 2.0kW. 3 Power settings. Fully adjustable thermostat. Wall mounting option. Illuminated control switch. Fitted with 1. Oil Radiators Convector Heater Downflow Bathroom Heater G20FH7 G2CH G2BFHT2 1.5 kw 2.0kW 2kW 7 Fin radiator 3 Power settings Pull cord adjust heat settings 3 Heat settings Fully adjustable thermostat for

More information

Intro. Intro. Table of Contents

Intro. Intro. Table of Contents EN Intro Intro Dear AHT Customer, Thank you for choosing the AHT underfloor heating system. It is designed to be simple to install and cost efficient to operate. This guide provides the information you

More information

KORABASE. new! Heat exchangers 04/18

KORABASE. new! Heat exchangers 04/18 Heat exchangers new! 04/18 MORE THAN YEARS QUALITY COMPLEXITY INNOVATION DESIGN To have a reliable partner for solving with both large and small projects in the area of heating is not a question of price.

More information

Bi-O Star. Supplementary sheet for manual Saunaheater 34.G MADE IN GERMANY. Druck Nr en 28.12

Bi-O Star. Supplementary sheet for manual Saunaheater 34.G MADE IN GERMANY. Druck Nr en 28.12 Bi-O Star GB Supplementary sheet for manual Saunaheater 34.G MADE IN GERMANY Druck Nr. 29342620en 28.12 D 1 Mount upper bracket with screwed-in tapping screw. Please consider all important installation

More information

Classic Mats Installation Manual

Classic Mats Installation Manual Classic Mats Installation Manual 1 Classic Mats WarmTouch Classic Mats are the ideal Electric floor warming systems, designed by DomoTecK, for installation under tile, stone or marble. WarmTouch Classic

More information

For more information on Tarkett go to

For more information on Tarkett go to Granit SD Toro SC STATIC CONTROL HOMOGENEOUS FLOORINGS VINYL iq Granit SD for static dissipation (10 6 R 10 8 Ω) iq Toro SC for static conductivity (5x10 4 R 10 6 Ω) Unique conductive iq PUR iq Unique

More information

Infrared Heating. Product catalogue INFRARED PANELS. Tel:

Infrared Heating. Product catalogue INFRARED PANELS.   Tel: Infrared Heating Product catalogue www.yandiya.net Tel: +86 136 9199 6563 INFRARED PANELS Content. 3. About us 4. Benefits of Infrared 6. Designer Glass Infrared Panels. 7. Satin Finished Frameless Panels.

More information

QuickNet System Installation Manual Manuel d installation du système QuickNet Manual de instalación del sistema QuickNet

QuickNet System Installation Manual Manuel d installation du système QuickNet Manual de instalación del sistema QuickNet QuickNet System Manual Manuel d installation du système QuickNet Manual de instalación del sistema QuickNet Floor heating system Système de chauffage par le plancher Sistema de calefacción de pisos Table

More information

Wall models HORTUS Patio heater for wall mounting 500/1000/1500 Watt incl. remote control Page of

Wall models HORTUS Patio heater for wall mounting 500/1000/1500 Watt incl. remote control Page of TABLE OF CONTENTS Hanging models... HORTUS Patio heater hanging model 500 Watt... HORTUS Patio heater Golden Tube hanging model 900/200/200 Watt... 2 HORTUS Patio heater hanging model 600/500 Watt... 3

More information

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING RADIANT PANELS COMMERCIAL BUILDINGS A guide to Radiant Panels, including our unique product range, consultancy service and accessories. INNOVATIVE VENTILATION & HEATING www.pricetwa.co.uk FLEXIBLE, INTEGRATED

More information

UNDERFLOOR ELECTRICAL HEATING

UNDERFLOOR ELECTRICAL HEATING ICPE 313 Splaiul Unirii, Bucharest, Romania Tel/Fax: +40 021 589 34 80 sicit@icpe.ro www.icpe.ro Alina Pǎun Marketing Assistant 0723046531 alina.paun@icpe.ro UNDERFLOOR ELECTRICAL HEATING Brief description

More information

Installation Manual Loose cable underfloor heating. A large print version can be downloaded from our website. www. underfloorheatinghq.co.

Installation Manual Loose cable underfloor heating. A large print version can be downloaded from our website. www. underfloorheatinghq.co. English Installation Manual Loose cable underfloor heating A large print version can be downloaded from our website www. underfloorheatinghq.co.uk Phone: 0800 328 4980 E-mail: enquiries@underfloorheatinghq.co.uk

More information