Operating instructions. for mobile radial fans designated for use with potentially explosive atmospheres according to zones 1, 2 and 22

Size: px
Start display at page:

Download "Operating instructions. for mobile radial fans designated for use with potentially explosive atmospheres according to zones 1, 2 and 22"

Transcription

1 Operating instructions for mobile radial fans designated for use with potentially according to zones 1, 2 and 22

2 Printed in Germany We reserve the right to make changes via technical development compared with the details and illustrations in these operating instructions. Reproduction, translation and copying in any form even in part subject to written approval from the manufacturer. These operating instructions will not be subject to any change service. Please contact the manufacturer for the current status. KARL KLEIN Ventilatorenbau GmbH Waldstrasse Aichwald Phone.: Fax.: Internet: Status: 01/ /2016 KARL KLEIN Ventilatorenbau GmbH Page 1

3 Contents 1 Preliminary notes Notes from the manufacturer to the operator The tasks of fan operators in potentially Warranty Symbols used Name and instruction plates Proper use Limits of use and features of proper use Improper use Safety Basic safety information Emissions Dust, gases and vapours Noise Vibrations Overheating/ambient conditions Transport and storage General function description Setting up/connection/commissioning/operation General safety instructions Setting up, connecting and installing Assembly and installation instructions for potentially Fan connection Information on maintenance, care and repair Maintenance and care Check bearings Maintain the supporting frames and chassis in working order Repair notes and procedures Contamination in case of repair returns Disposal EC-Declaration of Conformity /2016 KARL KLEIN Ventilatorenbau GmbH Page 2

4 1 Preliminary notes 1.1 Notes from the manufacturer to the operator Please follow the safety instructions. Please read carefully all safety instructions in these operating instructions. Familiarize yourself with the handling of the fan before starting work. It will be too late to do so once you are working. Do not allow anyone without the specialist knowledge to turn on and use this fan. Validity These operating instructions apply to all mobile ATEX fans with the following descriptions: MRV- (ENG or DNG) 3-6, -(ENG or DNG) 3-9.8, -(ENG or DNG) 4-14, -DNG , -DNG 5-16, -DNG 5-19 II 2G c IIB (T3 or T4) oder II 3G c IIB (T3 or T4) and II 3D c T125 C MRV-DNG 9-30, -DNG 9-43, -DNG 10-45, -(ENG or DNG) II 2G c IIB (T3 or T4) oder II 3G c IIB (T3 or T4) and II 3D c T125 C MRV-DMVL , -DMVL , -DMVL , -DMVL , (EMVL or DMVL) II 2G c IIB (T3 or T4) or II 3G c IIB (T3 or T4) and II 3D c T125 C 01/2016 KARL KLEIN Ventilatorenbau GmbH Page 3

5 Purpose of these operating instructions These operating instructions will be provided with the scope of delivery. They also serve as assembly instructions. The manufacturer drew up these operating instructions based on its knowledge and experience in construction, manufacturing and operation. They can be complemented by special instructions by the operator (e.g., for supervision and obligatory registration, in-house maintenance and servicing schedules). Symbolic illustration in these operating instructions The graphic illustrations and drawings represent the main view of a fan. They are not to scale neither do they show the proportions of each fan from the delivery range. The illustrations are only intended as a guide. The detailed dimensions and views are listed in the catalogue and available from the manufacturer. Copyright The copyright to these instructions remain with KARL KLEIN Ventilatorenbau GmbH. The operating instructions may not be reproduced or made available to unauthorized third parties or persons in part or in whole without prior approval from KARL KLEIN Ventilatorenbau GmbH. You as the operator will be responsible for the fan only being used by trained specialist personnel, adherence to the safety regulations and safety instructions and the health and safety at work precautions, the technical training of the operating personnel and their familiarization with the operating instructions. 01/2016 KARL KLEIN Ventilatorenbau GmbH Page 4

6 1.2 The tasks of fan operators in potentially explosive atmospheres What are essential here are the national prescriptions equal to the German Industrial Safety Ordinance (BetrSichV), the Equipment and Product Safety Act (GPSG) and the 11th Ordinance on the Equipment and Product Safety Act (11th GPSGV - Explosion Prevention Ordinance). They impose certain measures on equipment operators for their use in potentially. According to European directive 2006/42/EC and to article 3 of the German Industrial Safety Ordinance or equal national prescriptions of other members of the EU, the operator must carry out a hazard assessment in the area where the equipment is to be used. This should recognize and take account of the hazards that may occur when using the equipment in connection with the materials and the working environment. According to European directive 2006/42/EC and to article 4 of the German Industrial Safety Ordinance or equal national prescriptions of other members of the EU, the operator must take the necessary measures and select the equipment most suitable to the conditions at the workplace and has to ensure health and safety at work when used properly. For carrying out the hazard assessment and selecting suitable equipment, the operator must apply European Parliament and Council Directive 2006/42/EC on Industrial Safety and Directive 99/92/EC (the ATEX Directive for operators) and the respective harmonized norms (EN), e.g., EN 60079, Electrical apparatus for potentially explosive gas atmospheres or EN , Explosive atmospheres. The operator will be solely responsible for selecting the suitable equipment (fan) for the envisaged area and the envisaged application. 01/2016 KARL KLEIN Ventilatorenbau GmbH Page 5

7 1.3 Warranty KARL KLEIN Ventilatorenbau GmbH undertakes to provide a warranty within the framework of its general conditions of sale and delivery. Claims under the warranty will expire if the assembly instructions and procedures and in particular, the proper use as described in these operating instructions are not adhered to. No unauthorized conversions or changes may be made to the fan. Only use original parts and accessories approved by KARL KLEIN Ventilatorenbau GmbH. Using other parts may affect operation. The operator will be liable for any damage arising. KARL KLEIN Ventilatorenbau GmbH will not be liable nor will it provide any warranty with respect to repairs carried out by yourself or for defective assembly of the fan. 01/2016 KARL KLEIN Ventilatorenbau GmbH Page 6

8 1.4 Symbols used The following symbols will be used in these operating instructions. They support the instructions on safety and damage prevention. Attention: power surge! This describes possibly hazardous situations. Failure to observe such warnings can lead to death, serious injury or material damage. Attention! This describes possibly hazardous situations. Failure to observe this can lead to injury or damage. Note: Instructions how to use the delivered equipment for optimal operation and other useful information. 01/2016 KARL KLEIN Ventilatorenbau GmbH Page 7

9 1.5 Name and instruction plates Note: Type plates can be found on the air conveying part of the fan, on the on-off switch and on the drive motor. The data on the type plates are important for the proper use of the appliance. All plates must be legible at all times. Illegible and lost type plates and warning plates must be replaced immediately. IIB T4 Example The details on the name plates identify the respective fan type, the performance and describe the nature of the explosion protection. The details on the name plate correspond to the performance requirements ordered. These can change. Note: The values stated on the name plate are decisive. Please see the order confirmation for further approved values. 01/2016 KARL KLEIN Ventilatorenbau GmbH Page 8

10 2 Proper use Note: The fan is labelled II (2 or 3) G c IIB (T3 or T4) or II 3 D c T125 C. Appliance group II; Category 2 or 3; G = Gas; D = Dust; c = Constructive safety T3 = to 200 C surface temperature T4 = to 135 C surface temperature IIB = explosion subgroup T125 C = plain text details for dust explosion protection to 125 C surface temperature This KLEIN fan was designed and built for transporting non-aggressive and non-abrasive media. The fan can be used for extraction from potentially in zones 1, 2 and 22 (in accordance with directive 94/9/EC until April 19 th 2016 and in accordance with directive 2014/34/EC from April 20 th 2016 on). For Zone 1, this means that the fan is intended for use in such areas in which it is to be expected that an explosive atmosphere as a mixture of flammable substances in the form of gas, vapour or mist will occasionally occur with air d u r i n g n o r m a l operation. For Zone 2, this means that the fan is intended for use in such areas in which it is to be expected that an explosive atmosphere as a mixture of flammable substances in the form of gas, vapour or mist will n o t occur with air during normal operation. If this does however occur, this will only last for a s h o r t p e r i o d. For Zone 22, this means that the fan is intended for use in such areas in which it is to be expected that an explosive atmosphere as a mixture of flammable substances in the form of dust will n o t occur with air during normal operation. If this does however occur, this will only last for a s h o r t p e r i o d. Proper use also includes the observance of and adherence to the directions and information in these operating instructions. 2.1 Limits of use and features of proper use Proper use includes the following: The conveying medium may not contain any solid or liquid contamination. Place a filter by the fan intake if necessary (see KLEIN accessories list). Protective grids are also required on the inlet and outlet side. Ventilated air flow at fan inlet with higher or lower values than the specified limits of 0.8 to 1.1 bar for absolute pressure and 20 C to +60 C for temperature are not permitted, max. allowed oxygen content is 21 volume percent. Ambient atmospheres with higher or lower values than the specified limits of 0.8 to 1.1 bar for absolute pressure and 20 C to +40 C for temperature are not permitted, max. allowed oxygen content is 21 volume percent. Only use the fan with the inlet and outlet protective grids in place. No shocks, vibrations or oscillations may be transferred to the appliance from outside as these may impair the impeller balance leading to dangerous vibrations. 01/2016 KARL KLEIN Ventilatorenbau GmbH Page 9

11 2.2 Improper use Improper and hazardous use include in particular conveying explosive or flammable media in zones 0 or in the zones 20 or 21 for dust operation of the fan in a zone 0, 20 or 21 -ambient conveying ionized gases or hot ignitable mixtures exceeding temperatures of +60 C at the fan inlet conveying gas mixtures that contain other chemical reaction partners; conveying abrasive media; conveying without suitable inlet and outlet protective grids; operation without motor overload switch; transporting/carrying persons on the fans/frames; transporting/placing additional/foreign loads on the fans/frames; continued operation after toppling over or after the appliance has been exposed to strong vibrations/shocks; operation without continuous earthing/potential equalization; operation outdoors, exposed to the elements, solar radiation, lightening, without weather proofing or different from the established IP protection class; any other use deviating from proper use thus leading to danger. Travelling on uneven ground connected with shocks or vibrations, driving up or down over stairs or landings or the corresponding displacing of the appliance as well as spark creating transport / sliding should be generally avoided. An appliance may not be operated further once it has toppled over. This kind of use can for example, impair the balance of the impeller in such a way as to lead to adverse conditions such as impeller breaks, ignition risks, damage to objects and personal injury. The appliance should be returned to the manufacturer for repair if it topples over or sustains shocks or hazardous vibrations. 01/2016 KARL KLEIN Ventilatorenbau GmbH Page 10

12 3 Safety 3.1 Basic safety information KLEIN fans are designed and built according to recognized rules of technology, health and safety regulations and the requirements of Directive 94/9/EC (until April 19 th 2016) resp. Directive 2014/34/EC (from April 20 th 2016 on) for appliances and protective systems for proper use in potentially and according to the requirements of the Equipment and Product Safety Act (GPSG). They correspond to the latest technology. The use of fans can however lead to hazards, in particular, improper use or inappropriate use can lead to hazardous situations All instructions on the use of the fan must therefore be adhered to. 01/2016 KARL KLEIN Ventilatorenbau GmbH Page 11

13 Note: The fan may only be used in a technically perfect condition and with undamaged electrics. Use of a defective appliance or an unbalanced impeller c a n b e f a t a l. No materials that may be easily drawn in, e.g., polystyrene or cloths may be around the inlet area. Ensure sufficient distance to the suction inlet. The suction inlet may not be covered by items sucked in. The fan may only be used with a protective grid fitted on the suction side. Pay attention to the direction and area of air outlet. Any breaks to the paddle wheel may not lead to subsequent personal or material damage. The fan may only be used with a protective grid fitted on the outlet side. This fan may never be operated without the protection grids installed both on the suction and on the outlet side. This fan may not be operated under zone 0 conditions! Neither conveying medium into a zone 0 area nor conveying out of an zone 0 area are allowed! Depending on the size of the fan and how it is installed, there may be a considerable suction effect near the inlet area and a considerable blowing effect near the outlet area. The operators must take all measures to exclude any hazards due to this conduct by the fan. Electrical protective devices must correspond to the requirements of the machine in combination with which the fans are palled to be operated (e.g., motor overload switch, etc.). The personnel must be familiar with all measures describing the proper handling and specialist appropriate use of this appliance in these operating instructions. The operator should stipulate to its employees the nature and the wearing of personal protective equipment in a suitable manner and to an appropriate extent and ensure that this is adhered to. Especially, clothing and personal protective equipment have to correspond to the demands of explosion protection. You may not repair explosion protected fans yourself. Fans may only be repaired or preventively maintained by the manufacturer in order to maintain their explosion protection. The customer/operator is responsible for training and instructing the workers/employees. 01/2016 KARL KLEIN Ventilatorenbau GmbH Page 12

14 3.2 Emissions Dust, gases and vapours Noise The occurrence of hazardous emissions depends on the respective medium to be conveyed. Measures for safety and health protection have to be carried out by the operating company. The level of noise depends on the type of installation, the kind of mounting, environmental conditions and the respective operating point of the fan. Certain kinds of use can cause the fan to develop running noises that can reach a high level. Noise levels can be between 60 and 110 db (A). Please see the KLEIN catalogue for details on noise levels. If unavoidable work is to be carried out nearby, the operator should take appropriate noise protection measures in the context of his responsibility under the Industrial Safety Ordinance (BetrSichV) (e.g., hearing protection) Vibrations The balancing quality of KLEIN fans is such high quality that no dangerous vibrations occur ex-factory. No shocks, vibrations or oscillations may however be transferred to the appliance from outside as these may impair the balance leading to dangerous operating conditions. 3.3 Overheating/ambient conditions During every phasis of operation the machine has to be operated under sufficient cooling. E.g. the machine is not allowed to be covered, The max. allowed ambient and medium temperature may not be exceeded. No operation under direct solar radiation or nearby heat sources allowed. This device may not be operated under ambient conditions or under weather influence. 01/2016 KARL KLEIN Ventilatorenbau GmbH Page 13

15 3.4 Transport and storage Note: For transport to the operation site, use a lifting strap and secure the fan in such a way that it remains balanced. Only transport with suitable slinging and lifting gear for transporting. Avoid the appliance tipping over. Attention! Transporting can pose a danger of bruising and crushing between the fan, the frame and the surroundings. Unsuitable slinging and lifting gear can lead to the appliance falling down onto items or persons. Moving or transporting the fan over stairs or staircases may dangerously impair the balance of the impeller and is therefore not permitted. Landings must be crossed free of vibration, slowly and with care. ^ Please ensure that the earthing strap is in proper function meanwhile transport. Note: Dispose of packaging properly. Do not burn. Notes on storage Only store the fan in closed dry spaces wherever possible prior to transport to the installation location. Storage in open covered areas is only permissible for short periods. Protect the fan from all damaging environmental influences and mechanical damage. In the event of storage while out of operation, ball bearings (in the motor) may no longer be used and should be replaced no later than after two years or even earlier depending on the condition of the bearings. Please also study the documentation supplied for the motor. 01/2016 KARL KLEIN Ventilatorenbau GmbH Page 14

16 4 General function description KLEIN fans are radial fans with ball-bearing mounted electric drive. The respective medium will be drawn in axially and discharged radially in the desired direction (see fig.). 003_KL01_01 Flow direction of the medium 01/2016 KARL KLEIN Ventilatorenbau GmbH Page 15

17 5 Setting up/connection/commissioning/operation 5.1 General safety instructions Attention! Danger to life due to power surge There is a danger of power surge when connecting to the mains if not switched off previously. Carry out any connection, installation and any kind of repair work in absence of explosion endangerment! Always switch off the power before working on current carrying parts. The electrical connection may only be carried out by properly qualified and specialist trained electricians who can provide evidence of knowledge regarding setting up, connecting, commissioning and operation in potentially. Setting up and operation may only take place on horizontal level surfaces. Components fitted on the operator side may not affect the stability of the delivery of the fan and the frame. The operator will have to carry out additional safety/securing measures if necessary. Both the carrying of models with supporting frames and the tilting over and rolling models with mobile frames require minimum physical conditions and the wearing of suitable personal protective equipment such as sturdy safety shoes. The ergonomic principles for raising and lowering loads must be adhered to. Only use spark-inhibiting tools when setting up and installing in potentially explosive atmospheres. Electrical leads, command lines, etc. as well as hose lines and ventilation connections should be laid in such a way that either they cannot be driven over or so that they are reliably protected from being deformed or damaged when driven over. No loads may be placed on any electrical leads, command lines, etc. or on any hose lines or other ventilation connections. Cables must be wound up and stored in such a way that no bends, kinks or knots occur. Air leads may not be operated if they are bent or blocked. The operator must point out the hazards of stumbling due to connected hose lines, cables, etc. Cable, hose and pipe channels must be labelled and secured. The customer/operator may not carry out any changes to the electrical equipment supplied. The cable length and plugs supplied may not be removed, replaced or changed. Unless this has not been ordered, the operator must use the approved suitable mating plug with the plug that has been supplied. Specialist electricians are persons who are familiar with setting up, assembly, commissioning and operating the appliance/machine and who possess qualifications relating to their activities or who have undergone training or instruction according to the standards of safety technology in maintaining and using appropriate safety equipment as well as accident prevention. Setting up, connecting, commissioning and operation are, on the part of the operator/customer, dependent on the on site requirements of the fan and the functionspecific conditions relating to the set-up and operation site (with respect to the machine or the appliance). The customer/operator will bear the responsibility for the proper use and maintenance of safety and health protection during all life phases from the point of taking over the product. 01/2016 KARL KLEIN Ventilatorenbau GmbH Page 16

18 5.2 Setting up, connecting and installing Note: The connection lead with the plug has been pre-manufactured and may not be changed. If this is not included in the delivery by the manufacturer, the customer/operator should provide and connect a suitable, approved mating plug. There may be no departure from the instructions regarding the electrical connection. Only an appliance that corresponds to the requirements for use and the respective local conditions may be installed and used. Mobile models on wheels: For space-saving the handle bar can be slipped in and latched. Meanwhile moving the mobile ATEX fan the handle hast o be pulled-out and latched. Mobile models on wheels: For operation of the mobile ATEX fans the additional brackets have to be swinged out ans latched against toppling over. The earthing strap has to be connected professionally. 5.3 Assembly and installation instructions for potentially Further instructions that must be adhered to: Note: The method of fastening the fan to the chassis may not be changed. A connection for air conveyance is possible on the outlet flange or the inlet by using connections or intermediate flanges. Attention! Connection can pose a danger of the bruising of body parts between the fan, the frame and the surroundings. On site components such as hose lines, pipes, etc. that have to be connected must have a complete potential equalization to the fan and the chassis. On site components such as e.g. STORZ- couplings are not allowed to consist out of aluminium because of the danger of thermit reaction in contact with iron oxide particles. These componensts must consist out of brass or stainless steel. The environment should be free of items that may be drawn in if the fan is used in free in-take mode. The minimum distance from a wall to the cooling fan cover is: 30 mm. The flow velocity in connected ventilation components may not exceed 20 m/s or 10 m/s in filters/silencers. Motor protection is included in the on/off switch. It is dimensioned for the motor supplied. 01/2016 KARL KLEIN Ventilatorenbau GmbH Page 17

19 An on-site motor protection by way of fuses or motor protection switches should correspond to the motor's rated current according to the motor's specifications. The minimum specification for this (nominal current and t e time) is stated on the motor's type plate. The ATEX male connector is mechanically secured and cannot be switched on without mating female plug, refer operating instruction for explosion protected plug and socket system. Hose lines must be made in such a way that they cannot build up any electrostatic changes on the inside or outside surfaces. Metallic spirals should be incorporated into them in order to achieve sufficient mechanical stability. These should not collapse, constrict or inflate due to under or over pressure or following laying. The metallic spiral is to be laid bare on both ends of a hose line. The bare ends must be linked to the connecting components in an electrically conductive manner so that over the overall assembly or similar measures, there is a complete, constant electrical potential equalization of the overall system. The frame is mobile in the case of certain designs. It has additional folding supports that should be used to provide additional support against tipping over. Earthing strap has to be connected. 5.4 Fan connection Note: A rigid double connection both on the inlet and outlet side can lead to fan parts being damaged or broken. Structure-borne noise by electrical conductible disconnecting tarpaulin assembly Fan connection is possible either on the outlet flange or on the inlet intermediate flange. Connection examples: on the outlet flange on the inlet intermediate flange 005_KL01_01 01/2016 KARL KLEIN Ventilatorenbau GmbH Page 18

20 6 Information on maintenance, care and repair Note: The operator can also incorporate additional cleaning or maintenance intervals depending on how the fan is to be used and the respective design concept. Repairing damage or exchanging parts yourself is hazardous. This will render the explosion cover invalid. Attention! Possibility of material damage Unbalance will occur if balancing brackets (1) are displaced on or removed from the fan blades. 1 Under no circumstances should you repair the fan yourself. There is a danger of explosion if the appliance is assembled incorrectly and then used. 006_KL01_ Maintenance and care Check for contamination on the impeller in order to spot and prevent unbalance in time. Dust deposits should be regularly removed from parts of the appliance. The maximum permissible thickness of the dust deposits is 3 mm. Use in connection with combustible dust is only permissible in the case of suitability for the respective zone. 6.2 Check bearings Ball or roller bearings are part of the explosion-protected motors in the scope of delivery and in the case of the respective type, in the wheels on the chassis. Check at regular intervals the problem-free functioning of the ball or roller bearings by checking for running noise and have these replaced if necessary. The motor ball bearings must be replaced by the manufacturer or an authorized workshop at the latest after 20,000 operating hours or at the latest after 3 years, depending on what occurs earlier. 6.3 Maintain the supporting frames and chassis in working order Hand-held models: Regularly check the screw connections on the models with supporting frames and tighten these if necessary. There is for example a danger of injury when removing the carrying handle. 01/2016 KARL KLEIN Ventilatorenbau GmbH Page 19

21 Mobile models on wheels: Regularly check the wheels of the frames and renew these if necessary. The wheels should be exchanged if the tread is worn or the casing is broken. Roller bearings in the rollers: See section Repair notes and procedures Fans that are defective, have fallen over, fail to run in a circular manner or are damaged may no longer be operated. Damaged frames, electrical components, housings or driving rollers or unbalanced or adjusted minimum gap distances increase the risk of explosion. Do not repair appliances yourself, take them to the manufacturer for repair. This is the only place where proper specialist repairs and tested balancing are guaranteed. Only qualified personnel may remove the fan from use. The delivery of the fan and frame may also not be separated when being returned for repair. 6.5 Contamination in case of repair returns When returning a fan that is dirty or contaminated with hazardous substances, the manufacturer must also be provided with a complete list of the substances contained and potential for danger. If this list is missing, the manufacturer may reserve the right to delay the repair until the list has been submitted. In certain cases, the manufacturer may refuse to accept contaminated goods for repair or to return goods delivered, unprocessed and with costs. 7 Disposal The continued use of defective fans and/or their components such as impellers, rolling bearings, etc., as well as the frame can lead to material damage and personal injury and damage to the environment. The operator must dispose of all fan components properly in accordance with national and international laws and regulations. 01/2016 KARL KLEIN Ventilatorenbau GmbH Page 20

22 EC-Declaration of Conformity In accordance with Directive 2006/42/EC, annex II, part 1 A We hereby declare that the products: Mobile Low-pressure fans: MRV-ENG/-DNG 3-6, -ENG/-DNG 3-9.8, -ENG/-DNG 4-14, -DNG , -DNG 5-16, -DNG 5-19, Mobile Low-pressure high-performance fans: MRV-DNG 9-30, -DNG 9-43, -DNG 10-45, ENG/ -DNG 10-65, Mobile Medium-pressure high-performance fans: MRV-DMVL , -DMVL , -DMVL , -DMVL , -EMVL / -DMVL comply with the following Directives: Machinery Directive: 2006/42/EC ATEX- Directive: Until April 19 th 2016: 94/9/EC, from April 20 th 2016 on: 2014/34/EC EMC Directive: Until April 19 th 2016: 2004/108/EC, from April 20 th 2016 on: 2014/30/EC The labelling of the Fans must include the following details: II (2 or 3) D c T 125 C or II (2 or 3) G c IIB T3 oder T4 or II (2 or 3) GD c IIB T3 oder T4 Furthermore effectual directives: DIN EN : 2011 Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments The authorized person for the summary of the technical documents is the subscriber. City, date Aichwald, February 24 th 2016 Siegfried Seidler, Head of Engineering 01/2016 KARL KLEIN Ventilatorenbau GmbH Page 21

Installation and assembly instructions. for standard configuration radial blowers

Installation and assembly instructions. for standard configuration radial blowers Installation and assembly instructions for standard configuration radial blowers 001_KL01_01 Printed in Germany We reserve the right to change the information and illustrations shown in this operating

More information

Operating instructions. for radial fans for use in potentially explosive atmospheres

Operating instructions. for radial fans for use in potentially explosive atmospheres Operating instructions for radial fans for use in potentially explosive Printed in Germany We reserve the right to make amendments to the details and illustrations listed as a result of further technical

More information

TTV 4500 / TTV 4500 HP / TTV 7000

TTV 4500 / TTV 4500 HP / TTV 7000 TTV 4500 / TTV 4500 HP / TTV 7000 EN OPERATING MANUAL AXIAL FAN TRT-BA-TTV4500-4500HP-7000-TC-003-EN Table of contents The current version of the operating manual can be found at: Notes regarding the operating

More information

Operating Instruction Centrifugal fans without scroll (Translation of the Original) BA-RLE-AC /2014 RLE RLA

Operating Instruction Centrifugal fans without scroll (Translation of the Original) BA-RLE-AC /2014 RLE RLA Operating Instruction Centrifugal fans without scroll (Translation of the Original) EN RLE RLA Content 1. Important information 2. Safety notes 3.Technical description 4. Transport 5. Mounting / Installation

More information

Use and Maintenance Manual. WPA-E-N/Ex. II 2 G c Ex e II T3. ATEX marking: Explosion proof stand fans WPA-E-N/Ex

Use and Maintenance Manual. WPA-E-N/Ex. II 2 G c Ex e II T3. ATEX marking: Explosion proof stand fans WPA-E-N/Ex 1 Use and Maintenance Manual Explosion proof stand fans WPA-E-N/Ex ATEX marking: II 2 G c Ex e II T3 18.10.2016 Explosion proof stand fans WPA-E-N/Ex 2 Contents: 1. Introductory Remarks... 3 2. Application...

More information

235L G. Original-Gebrauchsanleitung V1/1115

235L G. Original-Gebrauchsanleitung V1/1115 235L 700335G Original-Gebrauchsanleitung V1/1115 GB/UK ENGLISH Table of contents 1.Safety... 20 1.1 Safety instructions... 20 1.2 Key to symbols... 23 1.3 Proper use... 24 2. General information... 25

More information

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN TTV 1500 / TTV 3000 EN OPERATING MANUAL CONVEYING FAN TRT-BA-TTV1500-3000-TC2016-26-004-EN Table of contents Notes regarding the operating manual... 2 You can download the current version of the operating

More information

Explosion Protection Enclosure with integrated measuring system

Explosion Protection Enclosure with integrated measuring system TR - ECE - BA - GB - 0099-08 02/21/2018 Translation of the original manual Explosion Protection Enclosure with integrated measuring system Explosion Protection Enclosure - Types _ADV75 _ADH75 ADH75 ADV75

More information

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control

USER S MANUAL NKP. Duct heater for supply air pre-heating with external control USER S MANUAL Duct heater for supply air pre-heating with external control CONTENTS Contents... 2 Safety requirements... 2 Purpose... 4 Delivery set... 4 Designation key... 4 Technical data... 5 Design

More information

Read these instructions before using and keep them available at all times!

Read these instructions before using and keep them available at all times! Rimi 700220 V3/0214 GB/UK ENGLISH Translation of the original instruction manual Read these instructions before using and keep them available at all times! 1. General information... 18 1.1 Information

More information

Read these instructions before using and keep them available at all times!

Read these instructions before using and keep them available at all times! A120407 V4/0713 GB/UK ENGLISH Translation of the original instruction manual Read these instructions before using and keep them available at all times! 1. General information... 16 1.1 Information about

More information

Operating instructions

Operating instructions Operating instructions (Translation of the original operating instructions) Type TEKA FILTERCUBE-MV TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen

More information

Mechanical seals external, single or double, to DIN EN 12756

Mechanical seals external, single or double, to DIN EN 12756 INSTALLATION AND OPERATING MANUAL Translation of the original manual Series SCK Bearing pedestal group: 0 Mechanical seals external, single or Keep for future use! This operating manual must be strictly

More information

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

User Manual GV25 GV35 GV702. Company information:   Original instructions GV12066 (1) User Manual Original instructions GV25 GV35 GV702 Company information: www.vipercleaning.eu info-eu@vipercleaning.com GV12066 (1) 2012-04-10 USER MANUAL ENGLISH TABLE OF CONTENTS Introduction... 4 Manual

More information

ANNEX GD-CERT-EX-EN SIT

ANNEX GD-CERT-EX-EN SIT SITEX ATEX Couplings ATEX ANNEX GD-CERT-EX-EN SIT S.p.A. Viale A. Volta, 2-20090 Cusago (MI) - Italy Tel. +39.02891441 Fax +39.0289144291 - info@sitspa.it www.sitspa.com ATEX Annex This Annex is an integral

More information

Read these instructions before using and keep them available at all times!

Read these instructions before using and keep them available at all times! 200065 V2/0614 GB/UK ENGLISH Translation of the original instruction manual Read these instructions before using and keep them available at all times! 1. General information... 16 1.1 Information about

More information

Operation Manual. Trash Water Pump ARTICLE Image similar

Operation Manual. Trash Water Pump ARTICLE Image similar Operation Manual Trash Water Pump ARTICLE 50781 Image similar Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved! Due to further

More information

Materials Handling and Intralogistics. Industrial Trucks. In accordance with the Directive Equipment for potentially explosive atmospheres (ATEX)

Materials Handling and Intralogistics. Industrial Trucks. In accordance with the Directive Equipment for potentially explosive atmospheres (ATEX) Materials Handling and Intralogistics Industrial Trucks In accordance with the Directive Equipment for potentially explosive atmospheres (ATEX) LEGAL NOTICE 1 Legal notice The guideline Industrial Trucks

More information

TRASCO ATEX Couplings

TRASCO ATEX Couplings TRASCO ATEX Couplings ATEX ANNEX GRM-CERT-EX-EN SIT S.p.A. Viale A. Volta, 2-20090 Cusago (MI) - Italy Tel. +39.02891441 Fax +39.0289144291 - info@sitspa.it www.sitspa.it ATEX Annex This Annex is an integral

More information

Operating instructions

Operating instructions ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 (0) 793-0 Fax +49 (0) 793-0 info@de.ebmpapst.com www.ebmpapst.com CONTENTS. SAFETY REGULATIONS AND NOTES. Levels of hazard warnings.

More information

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further. ATEX SOLUTIONS In order to apply a single level for health and safety requirements and to overcome barriers of trade within Europe, national regulations for explosion prevention were harmonized in 1975

More information

Procedure for the Approval of New Fire Detection and Alarm Technologies

Procedure for the Approval of New Fire Detection and Alarm Technologies VdS Guidelines for Automatic Fire Detection and Fire Alarm Systems VdS 3469en Procedure for the Approval of New Fire Detection and Alarm Technologies VdS 3469en : 2016-01 (01) Publisher and publishing

More information

Air handling unit. BlauAir RH USER S MANUAL

Air handling unit. BlauAir RH USER S MANUAL Air handling unit EN USER S MANUAL CONTENTS Safety requirements... 2 Purpose... 4 Delivery set... 4 Designation key... 4 Technical data... 5 Unit design and operation logic... 7 Installation and set-up...

More information

EtherCAT Box Modules (EPxxxx-xxxx)

EtherCAT Box Modules (EPxxxx-xxxx) Notes about operation of EtherCAT Box Modules (EPxxxx-xxxx) in potentially explosive areas (ATEX) Version: 1.1.0 Date: 2011-06-10 Table of Contents Table of Contents 1 Foreword 1 1.1 Notes on the documentation

More information

AXIAL FAN User s manual. Quiet-dMEV 100 DC.

AXIAL FAN User s manual. Quiet-dMEV 100 DC. AXIAL FAN User s manual Quiet-dMEV 100 DC www.ventilation-system.com CONTENTS Delivery set... 6 Brief description... 6 Operating guidelines... 6 Designation key... 7 Installation and set-up... 7 Fan options...

More information

WPA-S-N/Ex. Use and Maintenance Manual. Explosion proof stationary fan. II 2 G c Ex e II T3. ATEX marking:

WPA-S-N/Ex. Use and Maintenance Manual. Explosion proof stationary fan. II 2 G c Ex e II T3. ATEX marking: 1 Use and Maintenance Manual Explosion proof stationary fan WPA-S-N/Ex ATEX marking: II 2 G c Ex e II T3 15.02.2017 Explosion proof stationary fan WPA-S-N/Ex 2 Contents: 1. Introductory Remarks... 3 2.

More information

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P Contents Description Data Sheet No. Page Overview P-1.50.001E 117-118 Technical Data SFI-plus P-1.50.002E-1, 2 119-120 Dimensions

More information

OPTIBAR DP 7060 Supplementary Instructions

OPTIBAR DP 7060 Supplementary Instructions OPTIBAR DP 7060 Supplementary Instructions Differential pressure transmitter Category ATEX II 1/2G, 2G Ex db ia IIC T6...T1 Ga/Gb, Gb IECEx Ex db ia IIC T6...T1 Ga/Gb, Gb Housing Aluminium: Single chamber,

More information

AZN ATEX INSTALLATION AND MAINTENANCE

AZN ATEX INSTALLATION AND MAINTENANCE ZerAx AZN ATEX INSTALLATION AND MAINTENANCE 924714-0 English 924714-0 GB ZerAx axial flow fans type AZN ATEX Installation and maintenance 1. Application 2. Handling 2.1 Marking 2.2 Weight 2.3 Temperature

More information

model No: ir20.v2 FUSE

model No: ir20.v2 FUSE InstructioNS for: model No: ir20.v2 INFRARED PARAFfIN / KEROSENE / diesel HEATER 70000Btu 230V Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according

More information

Vacuum cleaner Instruction manual

Vacuum cleaner Instruction manual CSR Tools & Consumables Triniti 3, Level 5 39 Delhi Road North Ryde NSW 23 Australia http://www.csr.com.au Vacuum cleaner Instruction manual IMPORTANT: Read and understand all instructions before using.

More information

SOLDERING GUN PLP 100 A1

SOLDERING GUN PLP 100 A1 SOLDERING GUN PLP 100 A1 SOLDERING GUN Operation and Safety Notes 6 Before reading, unfold the page containing the illustrations and familiarise yourself with all functions of the device. GB / IE Operation

More information

Operation and Maintenance Instruction Manual. Escalator Deep Cleaner. Rotomac 360. Am Riedweg 15 D Salem

Operation and Maintenance Instruction Manual. Escalator Deep Cleaner. Rotomac 360. Am Riedweg 15 D Salem Operation and Maintenance Instruction Manual Escalator Deep Cleaner Rotomac 360 Am Riedweg 15 D 88682 Salem Telefon +49(0)7553.82740-0 Telefax +49(0)7553.82740-40 info@juma-reinigungstechnik.de www.juma-reinigungstechnik.de

More information

en Inverter FU 4/5. Operator s Manual

en Inverter FU 4/5. Operator s Manual 0201424en 006 12.2012 Inverter FU 4/5 Operator s Manual Manufacturer Wacker Neuson Produktion GmbH & Co. KG Preußenstraße 41 80809 München www.wackerneuson.com Tel.: +49-(0)89-354 02-0 Fax: +49-(0)89-354

More information

TFV 900 OPERATING MANUAL RADIAL FAN TRT-BA-TFV900-TC-001-EN

TFV 900 OPERATING MANUAL RADIAL FAN TRT-BA-TFV900-TC-001-EN TFV 900 EN OPERATING MANUAL RADIAL FAN TRT-BA-TFV900-TC-001-EN Table of contents Notes regarding the operating manual... 1 Safety... 2 Information about the device... 3 Transport and storage... 4 Start-up...

More information

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS IN POTENTIALLY EXPLOSIVE ATMOSPHERES. ET 105:2001 (Second Edition)

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS IN POTENTIALLY EXPLOSIVE ATMOSPHERES. ET 105:2001 (Second Edition) NATIONAL RULES FOR ELECTRICAL INSTALLATIONS IN POTENTIALLY EXPLOSIVE ATMOSPHERES ET 105:2001 (Second Edition) Consolidated Amendments, Corrigenda and Errata 01/2010 Introduction When ET 105:2001 was originally

More information

FHA 1100 A1 Domestic Water Pump

FHA 1100 A1 Domestic Water Pump FHA 1100 A1 Domestic Water Pump Translation of original operation manual 6 Before reading, unfold the page containing the illustrations and familiarise yourself with all functions of the device. / Translation

More information

Operating manual 1 SAFETY REGULATIONS AND INFORMATION. Original operating manual INDEX. RG CPAP 24 V mit Powermodul 24V sensorless

Operating manual 1 SAFETY REGULATIONS AND INFORMATION. Original operating manual INDEX. RG CPAP 24 V mit Powermodul 24V sensorless Operating manual RG CPAP 24 V mit Powermodul 24V sensorless 1 SAFETY REGULATIONS AND INFORMATION Read the operating manual carefully before commencing work at the product. Pay attention to the following

More information

CRU-S Series Stainless Steel Condensate Recovery Unit

CRU-S Series Stainless Steel Condensate Recovery Unit IM-UK-CRU-S UK Issue 1 CRU-S Series Stainless Steel Condensate Recovery Unit 1. Safety information 2. General product information 3. Installation 4. Commissioning 5. Storage, shutdown and equipment protection

More information

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans Operating Instructions Edition 11/2005 Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA sitrans Introduction 1 General safety instructions 2 SITRANS Process monitoring Ex-barrier

More information

3 in 1 Garden Vacuum 9255 Instructions for Use

3 in 1 Garden Vacuum 9255 Instructions for Use Leaf Blower-Vac/Patio Cleaner Technical Specifications Model GY 8113 Rated voltage 230V Rated frequency 50Hz Rated power consumption 3000W Mains fuse(delayed action) 13A Speed 15000 rpm Max. blower air

More information

Operating Instructions ATEX - Plug fans (Translation of the original) II 2G c IIB(+H2) T4 BA-CFD-RLM-ATEX /2015 RLM E6 RLM E3 RLM G6

Operating Instructions ATEX - Plug fans (Translation of the original) II 2G c IIB(+H2) T4 BA-CFD-RLM-ATEX /2015 RLM E6 RLM E3 RLM G6 Operating Instructions ATEX - Plug fans (Translation of the original) EN II 2G c IIB(+H2) T4 BA-CFD-RLM-ATEX 3.7 03/2015 RLM E6 RLM E3 RLM G6 RLM 55 RLM 56 BA-CFD-RLM-ATEX 3.7 12/2015 Contents 1. Revision

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-i Edition 09/2018 CONTENTS 1 Safety instructions 3 1.1 General notes... 3 1.2 EU conformity... 3 1.3 Approval according to the IECEx scheme...

More information

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278 Illustration shows item no Z-3278 Operating manual BlueMobil eco Item no: Z-3278 Original operating manual Important Copyright It is essential that you read this manual thoroughly before the initial operation

More information

OPERATION AND MONTAGE MANUAL ROOF FANS

OPERATION AND MONTAGE MANUAL ROOF FANS NO RFEC/U/2017-1 (EN) (valid since 18.08.2017) ROOF FANS RF/EC...-... / RFV/EC...-... Venture Industries Sp. z o.o. is not responsible for any damage caused by improper use of the fan and reserves the

More information

Explosion-protected actuator Page 259 of 292

Explosion-protected actuator Page 259 of 292 Explosion-protected actuator Page 259 of 292 9.5 Explosion-protected actuator 9.5.1. What is an explosion? A flammable substance and oxygen, in a certain mixture, must be available to set off an explosion.

More information

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59 SOUND-INSULATED FAN OPERATION MANUAL _v.1(2)-en.indd 1 10.08.2015 15:20:59 CONTENT Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 3 Fan design 4 Delivery

More information

DUST EXTRACTOR MODEL No: CDE1000

DUST EXTRACTOR MODEL No: CDE1000 DUST EXTRACTOR MODEL No: CDE000 Part No:64765 OPERATING & MAINTENANCE INSTRUCTIONS GC054 INTRODUCTION Thank you for purchasing this CLARKE Dust Extractor which is intended to keep work areas free from

More information

Waste water ejection unit

Waste water ejection unit Waste water ejection unit Over ground box SWH 500/50-80 SWH 500/50-80 Operation manual Table of contents: Page Declaration of conformity... 3 1. General... 4 1.1 Introduction... 4 1.2 Enquiries and orders...

More information

TD E. OPERATION MANUAL CMVeco Plastic industrial fan

TD E. OPERATION MANUAL CMVeco Plastic industrial fan OPERATION MANUAL CMVeco 125-400 Plastic industrial fan Agent: COLASIT Order No.: Fan type: Year of manufacture: Faulenbachweg 63 Phone: +41 33 655 61 61 Fax: +41 33 654 81 61 e-mail: info@colasit.ch For

More information

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original)

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original) Montageanleitung (Original) (Translation of the original) DE MA_ 1.0 06/2014 Taperlock Clamping-bush system _0 _1 Fixed hub Inlet nozzle with IMV 1. Revision index Revision Date MA_ 1.0 06/2014 2. Safety

More information

Smart encoders & actuators

Smart encoders & actuators Declaration of Conformity The manufacturer: LIKA ELECTRONIC SRL 36010 Carrè (VI) - Italy hereby declares that the following products (only when correctly assembled): XAC8018/1PB-14 XAC8018/1CB-14 XAC8018/1FD-14

More information

RLM 56. Operating Instructions, ATEX Centrifugal fans without scroll, direct driven (Plug fans) (Translation of the original) II 2G c IIB T4

RLM 56. Operating Instructions, ATEX Centrifugal fans without scroll, direct driven (Plug fans) (Translation of the original) II 2G c IIB T4 Operating Instructions, ATEX Centrifugal fans without scroll, direct driven (Plug fans) (Translation of the original) EN II 2G c IIB T4 BA-CFD-RLM-ATEX 3.1-08/2010 RLM 55 RLM 56 Contents 1. Revision Index...

More information

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil 60. Item no: Z-3285

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil 60. Item no: Z-3285 Operating manual BlueMobil 60 Item no: Z-3285 Original operating manual Illustration shows item no Z-3285 Important Copyright It is essential that you read this manual thoroughly before the initial operation

More information

2500 Electric Blower Vac

2500 Electric Blower Vac 2500 Electric Blower Vac Owner s Manual Important Please read this Owner s Manual and the Express Warranty before using this product. The Warranty does not cover damage due to misuse or failure to follow

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-nA Edition 08/207 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4

More information

Operating manual 1 SAFETY REGULATIONS AND INFORMATION. Original operating manual INDEX 2218 F/2TDH4P

Operating manual 1 SAFETY REGULATIONS AND INFORMATION. Original operating manual INDEX 2218 F/2TDH4P Operating manual 2218 F/2TDH4P 1 SAFETY REGULATIONS AND INFORMATION Read the operating manual carefully before commencing work at the product. Pay attention to the following warnings to avoid risk to persons

More information

Operation and Maintenance Instruction Manual

Operation and Maintenance Instruction Manual Operation and Maintenance Instruction Manual Am Riedweg 15 D 88682 Salem Telefon +49(0)7553.82740-0 Telefax +49(0)7553.82740-40 info@juma-reinigungstechnik.de www.juma-reinigungstechnik.de JUMA Reinigungstechnik

More information

Operator s manual. Battery charger C 48/ en / 03

Operator s manual. Battery charger C 48/ en / 03 Operator s manual Battery charger C 48/13 03.2015 5100010183en / 03 Manufacturer Wacker Neuson Produktion GmbH & Co. KG Preussenstrasse 41 80809 Munich www.wackerneuson.com Tel.: +49-(0)89-354 02-0 Fax:

More information

Operating instructions Electric agitator RE80Ex. T-Dok-520-GB-Rev.5 Article no Translation of the original operating instructions

Operating instructions Electric agitator RE80Ex. T-Dok-520-GB-Rev.5 Article no Translation of the original operating instructions GB Operating instructions Electric agitator RE80Ex T-Dok-520-GB-Rev.5 Article no. 200-0332 Translation of the original operating instructions Thank you for selecting a Krautzberger product. This product

More information

OPERATION AND MONTAGE MANUAL ROOF FANS

OPERATION AND MONTAGE MANUAL ROOF FANS NO RF/U/2017 (ENGLISH) (valid since 13.10.2017) ROOF FANS RF / RFV Venture Industries Sp. z o.o. is not responsible for any damage caused by improper use of the fan and reserves the right to modify this

More information

AXIAL FANS USER S MANUAL

AXIAL FANS USER S MANUAL AXIAL FANS USER S MANUAL WARNING! Disconnect the fan from power supply prior to any connection, servicing and repair operations. Only duly qualified electricians with valid electrical permit for electric

More information

Operating Instructions

Operating Instructions Operating Instructions TEKA Cartmaster Type PF-W 1, PF-W 2 TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen Tel.: +49 (0) 2863 9282-0 Fax: +49 (0)

More information

Propane Flame Projector Safety instructions and operating manual

Propane Flame Projector Safety instructions and operating manual Bigflame Propane Flame Projector Safety instructions and operating manual 1 Flame projector Bigflame Safety instructions Caution The directions in this manual must be followed strictly. It is imperative

More information

Operating Instructions!

Operating Instructions! Operating Instructions! 3 4 Oscillation MO 16.2 / MO 40 Example 3 4 MO 16.2 The unit has to be strictly used according to the instruction manual. Keep the unit away from children and from persons not instructed

More information

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death. Please Read: Safety Precautions DC AC In order to ensure that this product is used safely, be sure that you read and understand the following precautions fully and use the product only as directed. Be

More information

KK70 Silent. Installation and Operating Instructions L V001

KK70 Silent. Installation and Operating Instructions L V001 KK70 Silent Installation and Operating Instructions 0881100001L02 1502V001 Contents Important information 1 Documentation 3 11 Warnings and symbols 3 12 Notes on copyright 3 2 Safety 4 21 Intended use

More information

Translation of the Original Operating Instructions MAB 100 K

Translation of the Original Operating Instructions MAB 100 K Translation of the Original Operating Instructions MAB 100 K 5 6 4 7 3 2 8 1 9 11 10 General instructions Table of Contents General instructions...3 Safety...5 Components / delivery contents...9 Before

More information

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A Millo / Millo pro Nr. 1804-x000 / 1805-x000 0609 21-6543 A Ideen für die Dentaltechnik 1 2 3 4 5 6 7 8 9 10 11 12 Millo / Millo pro No. 1804-x000 / 1805-x000 ENGLISH Content Introduction... 15 Symbols...

More information

VERSAFLOW VORTEX Supplementary instructions

VERSAFLOW VORTEX Supplementary instructions VERSAFLOW VORTEX Supplementary instructions Vortex flowmeter Equipment category II 2G CONTENTS VERSAFLOW VORTEX 1 Safety instructions 3 1.1 General notes... 3 1.2 EC conformity... 3 1.3 Approval according

More information

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX

SCHMIDT Flow Sensor SS Ex - Supplementary instructions for use in explosive atmospheres ATEX SCHMIDT Flow Sensor SS 20.600 Ex - Supplementary instructions for use in explosive atmospheres ATEX SCHMIDT Flow Sensor SS 20.600 Ex ATEX version Table of Contents 1 Important information... 3 2 Storage

More information

OPTIBAR P 1010/2010 C Supplementary instructions

OPTIBAR P 1010/2010 C Supplementary instructions OPTIBAR P 1010/2010 C Supplementary instructions Pressure transmitter Equipment category II 1G / Ga, II 1D / Da in protection type intrinsic safety Exi KROHNE CONTENTS OPTIBAR P 1010/2010 C 1 Safety instructions

More information

BSK-RPR Fire Damper. Additional operating instructions according to

BSK-RPR Fire Damper. Additional operating instructions according to Additional operating instructions according to BSK-RPR Fire Damper Contents GENERAL CONDITIONS... 1 DESCRIPTION... 3... 4 EC Certificate of Conformity 0761 CPD 0245 Declaration of Performance 09-22-DoP-BSK-RPR-2013-07-01

More information

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL TUBO-M/MZ AXIS-QA AXIS-Q TUBO-F AXIS-QR AXIS-F AXIS-QRA AXIS-QA G AXIAL FANS EN OPERATION MANUAL www.blaubergventilatoren.de CONTENT 3 Introduction 3 General 3 Safety rules 3 Transport and storage requirements

More information

BMA 0010 Instruction and Installation Manual Oil-Air Cooler ACN

BMA 0010 Instruction and Installation Manual Oil-Air Cooler ACN BMA 0010 Instruction and Installation Manual Oil-Air Cooler ACN Compact oil-air cooler High cooling capacity High operating pressure Low pressure loss Low noise emission Contents 1. Basic information 3

More information

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S EN OPERATING MANUAL INFRARED HEATING PANEL TRT-BA-TIH300S-TIH400S-TIH500S-TIH700S-TIH900S-TIH1100S-TC-002-EN Table of contents Notes

More information

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use! Mess-, Regel- und Überwachungsgeräte für Haustechnik, Industrie und Umweltschutz Lindenstraße 20 74363 Güglingen Telefon +49 7135-102-0 Service +49 7135-102-211 Telefax +49 7135-102-147 info@afriso.de

More information

The plant meets the requirements of the current FSS 5 Checklist for Vessel Process Plants

The plant meets the requirements of the current FSS 5 Checklist for Vessel Process Plants FSS 5, Attachment 3: Safety list - Vessel Process Plants (powered devices, machines and facilities - not including industrial trucks) within Freudenberg Date: 2009-03-30 - Revision: 01 I. Nature of the

More information

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN AIRGOCLEAN 10 E EN OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN Table of contents Notes regarding the operating manual... 1 You can download the current version of the operating manual and

More information

Operating instructions. Web Cleaner 1 / 2. Air Line

Operating instructions. Web Cleaner 1 / 2. Air Line Operating instructions Web Cleaner 1 / 2 Air Line page 2 Operating instructions for Web Cleaner 1 Web Cleaner 2 Contents 1 Product description... 5 1.1 Application... 5 1.2 Function principle... 5 1.3

More information

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315

USER S MANUAL. Centrifugal inline fan. VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125. VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315 USER S MANUAL VKMz 100 Q VKMz 100 VKMz 125 Q VKMz 125 VKMz 150 VKMz 160 VKMz 200 Q VKMz 200 VKMz 250 Q VKMz 250 VKMz 315 Q VKMz 315 Centrifugal inline fan VKMz CONTENTS Contents... 2 Safety requirements...

More information

BKA-EN Fire Damper. Additional operating instructions according to

BKA-EN Fire Damper. Additional operating instructions according to Additional operating instructions according to BKA-EN Fire Damper Contents GENERAL CONDITIONS... 1 DESCRIPTION... 3... 4 EC Certificate of Conformity 0761 CPD 0244 Declaration of Performance 09-19-DoP-BKA-EN-2013-07-01

More information

Mechanical Seal RG-4 stationary, double, liquid sealed

Mechanical Seal RG-4 stationary, double, liquid sealed Series SCK INSTALLATION AND OPERATING MANUAL Translation of the original manual Mechanical Seal RG-4 stationary, double, liquid sealed Keep for future use! This operating manual must be strictly observed

More information

Part No KEMPER Filter-Master XL

Part No KEMPER Filter-Master XL Part No. 150 0492 KEMPER Filter-Master XL 1. Application and Mode of Operation.... 2 2. Safety Instructions......... 2 3. Placing into Operation...... 3 4. Operation Elements and Function... 3-4 5. Installation

More information

Combivac Operating Instructions Combivac

Combivac Operating Instructions Combivac Combivac 17-36 Operating Instructions Combivac General Table of contents General...2 Table of contents...2 Information about the operating instructions...3 Liability...3 Notices in the operating instructions...3

More information

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date: Installation and Operating instructions for C9900-U330-0010 battery pack Version: 2.0 Date: 2017-03-23 Table of contents Table of contents 1 Foreword 3 1.1 Notes on the Documentation 3 1.1.1 Liability

More information

100T Electric Shop Press

100T Electric Shop Press 100T Electric Shop Press Operation Manual 1 Important Information 1.1 Safety Information 1.1.1 Hazard Symbols Used in the Manuals This manual includes the hazard symbols defined below when the operations

More information

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor Product ID Type # Product # Drawing # DSF 1210.00 SHV Ex-atex (2m) 374Z-05066 110428F1 DSF 1210.00 SHV Ex-atex (5m) 374Z-05176 110428F1 DSF 1210.00 SHV Ex-atex (10m) 374Z-05590 110428F1 DSF 1410.00 SHV

More information

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL INLINE CENTRIFUGAL FAN OPERATION MANUAL www.blaubergventilatoren.de CONTENT 3 Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 4 Fan design 4 Delivery

More information

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content 8 Appendix 8.1 Wiring examples...4 8.2 Start configuration...4 8.3 Sensor configuration...4 8.4 Actuator configuration...5 Operating instructions.............pages 1 to 6 Original 9 EU Declaration of conformity

More information

UV Flame Supervision System

UV Flame Supervision System 7 783 UV Flame Supervision System DETACTOGYR LFE50 Series 02 ISO 9001 The LFE50 is a self-checking UV flame supervision system designed for use with continuously operating burners or for burners running

More information

Operation Manual. Pond Pump Series HJ and CQP

Operation Manual. Pond Pump Series HJ and CQP Operation Manual Pond Pump Series HJ and CQP Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved! Due to further developments,

More information

INFRARED PARAFfIN / KEROSENE / model No: ir20.v2 1. SAFETY INSTRUCTIONS RECOMMENDED FUSE RATING: 5AMP

INFRARED PARAFfIN / KEROSENE / model No: ir20.v2 1. SAFETY INSTRUCTIONS RECOMMENDED FUSE RATING: 5AMP InstructioNS for: INFRARED PARAFfIN / KEROSENE / diesel HEATER model No: ir20.v2 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these

More information

CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE User instructions Model X46 Escalator and Travelator cleaner CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE 03-7845-0000 Iss.1 07/04 Fig 1 Fig 2 2 Contents Page 1 Product information... 4 1.1

More information

STORAGE, ERECTION, OPERATION AND MAINTENANCE MANUAL FOR CENTRIFUGAL FANS MODEL - MXE

STORAGE, ERECTION, OPERATION AND MAINTENANCE MANUAL FOR CENTRIFUGAL FANS MODEL - MXE ISO 9001 : 2000 STORAGE, ERECTION, OPERATION AND MAINTENANCE MANUAL FOR CENTRIFUGAL FANS MODEL - MXE CUSTOMER : 1 CONTENTS 1 SAFETY... 5 1.1 General... 6 1.2 Description of symbols and pictograms... 6

More information

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d. Additional Operating Instructions SITRANS F Vortex flowmeters Ex-d Edition 09/208 CONTENTS Safety instructions 3. General notes... 3.2 EU conformity... 3.3 Approval according to the IECEx scheme... 3.4

More information

ExDetector IRCO2. ExDetector IRHC. Operating and Installation Instructions. Gas Detection and Warning Systems

ExDetector IRCO2. ExDetector IRHC. Operating and Installation Instructions. Gas Detection and Warning Systems IRCO2 IRHC Operating and Installation Instructions Gas Detection and Warning Systems Important Instructions Prerequisites for safe and reliable operation of the system: Appropriate transport and handling

More information

IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D

IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D IDE 20 D / IDE 30 D / IDE 50 D / IDE 60 D / IDE 100 D EN OPERATING MANUAL OIL HEATER TRT-BA-IDE20D-30D-50D-60D-100D-TC-001-EN Table of contents Notes regarding the operating manual... 1 Safety... 2 Information

More information

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN Inspection Light LED Operating instructions Additional languages www.stahl-ex.com Contents 1 General Information...3 1.1 Manufacturer...3 1.2 Information regarding the operating instructions...3 1.3 Conformity

More information

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro 2006/01 Content Important Information 1. Notes... 3 1.1 CE - Labeling... 3 1.2

More information