Applied systems. Catalogue. Climate comfort. All Seasons. Heating. Air Conditioning. Applied Systems. Refrigeration

Size: px
Start display at page:

Download "Applied systems. Catalogue. Climate comfort. All Seasons. Heating. Air Conditioning. Applied Systems. Refrigeration"

Transcription

1 Applied systems All Seasons Climate comfort Catalogue Heating Air Conditioning Applied Systems Refrigeration

2

3 No matter how large your premises and whatever your air conditioning needs, there is a Daikin chilled water system to suit your requirements. It is a system that has proved its worth in a multiplicity of situations - from industrial sites to retail warehouses, hotels and department stores. The careful development of closely matched compressor/refrigerant combinations, has enabled Daikin to produce complete ranges of water chillers genuinely optimised for use with R-34a, R-407C and R-40A refrigerants. Daikin chillers offer the ultimate in flexibility and control a reflection of the advanced technology inherent within them. Unique in their precision, power, low operating noise, easy maintenance and low running costs, Daikin chillers represent the sure and safe route to an indoor environment that is comfortable, clean and consistent. As a manufacturer that makes its own refrigerant and compressors, Daikin has total control at the production stage. Daikin also offers a complete range of air handling units to meet modern day requirements for better indoor air quality and increased insulation standards. It is this unique combination of advanced technology, experience and reliability that makes Daikin the obvious choice and long term solution for the professional. Table of Contents PRODUCT PORTFOLIO - Air cooled 04 PRODUCT PORTFOLIO - water cooled 06 options PORTFOLIO 08 accessories PORTFOLIO 0 About daikin ENVIRONMENTAL AWAReness 3 Heat recovery 4 reliable & efficient 6 condensing unit 76 WATER COOLED 8 condenserless chiller 06 D.I.C.N. 6 Hydraulic module & buffer tank 7 FAN COIL UNITS 8 AIR handling units 34 MEASURING CONDITIONS 40 AIR COOLED 8 3

4 Product portfolio air cooled Type Compr. Refr. Mode Reference Packshot swing ewaq acv3 ewaq009-0acv3 scroll R-40A ewaq009-03acw swing scroll R-40A ewyq acv3 ewyq009-0acv3 ewyq009-03acw euwac5-0fbzw R-407C euwa*5-4kbzw scroll euwy*5-4kbzw Ts R-40A ewaq080-60dayn ewyq080-50dayn ewad00-40e-ss AIr cooled Condensing units screw screw R-34a R-34a ewad00-400e-sl ewad d-ss ewad80-530d-sl ewad80-530d-sr ewad0-490d-sx ewad50-60d-xs ewad40-600d-xr ewad00-590d-hs ewyd50-580bzss ewyd50-570bzsl ewad330-50bzss/sl ewad330-50bzxs/xl/xr ewad670-c8czxs/xl ewad640-c7czxr ewad650-c0c-ss/sl ewad60-c9c-sr ewad760-cc-xs/xl ewad740-cc-xr ewad80-c6c-ps/pl ewad80-c6c-pr erad0-490e-ss erad0-460e-sl

5 500,000,000 kw = Cooling only = heating only = heat pump = heating = Cooling ,037,095 C0 C,36 C,308 C3,450,545,6 3 C4 C5 C6,709 3 C7, ,053,3,5,359,439, ,04,68,47,30,367,468,550,639,7,83,854,90, C C0 C ,03,70,35,33,443,545,63, ,064,5 990 C0 C C, ,00,,70,3,48,556,63 C3 H4 H5 C6 756 C7 C8 C9 C0 C C C,48,49,538,6,74,80,875,9 C3 C4 C5 C6 C ,74,795, ,00,80,349,55,409,596,685,768,858,90,953, C0 C C3 C4 C5 C C C C3 C4 H4 C5 C6 C7 C8 C9 C C0 C C C3 H4 C5 C6 C8 C9 C ,074,58,79,390,474, C0 C C C3 H4 H5 C6 C C C3 C4 C5 C6 C7 C8 C9 C0 C C

6 Product portfolio water cooled Type Compr. Refr. Mode Reference Packshot water cooled scroll R-407C screw R-34a ewwp04-065kbwn ewwp090-95kbwn ewwd0-560j-ss ewwd70-600g-ss ewwd90-650g-xs ewwd340-c8i-ss ewwd360-ci-xs ewwd380-cbjynn R-40A ewwq380-c0b-ss ewwq40-cb-xs 4 40 ewwd30-c0fzxs CenTRI- FUgAL R-34a DwsC 300 DwDC scroll R-407C ewlp0-65kbwn Condenserless chiller screw R-34a ewld0-530j-ss ewld60-550g-ss ewld30-c7i-ss Daikin Europe N.V. participates in the Eurovent Certification programme for Air conditioners (AC), liquid Chilling packages (lcp) and fan coil units (fcu), Check ongoing validity of certificate online: or using:

7 500,000,000 9,000 kw = Cooling only = heating only = heating = Cooling , , C0,038 C,34 C , C0 C , C0 993,07,069,55, C C3,6,7,6,74 3 C4,03,33,346 3 C5,40, C6 C7,363,47,507,7,50 3 C8,66,730, ,007,055,85,55,35,460,584,748,888, C0 C C C3 C4 C5 C6 C7 C9 C ,037,6,58,70,369,449,573,733,863,00, C0 C C C3 C4 C5 C6 C7 C9 C0 C , C C0,033 3 C,078 C,5 3 3 C3,88 3 C4,67 3 C5,39 C6, C7,4 3 7

8 options portfolio integrated Hydronics Type Compr. Refr Mode Reference Products single pump contact Twin pump contact single pump Twin pump High esp pump OPsC OPTC OPsP OPTP OPHP Air Cooled swing scroll R-40A R-40A R-407C R-40A ewaq-acv std ewyq-acv std ewaq-acv std ewaq-acw std ewyq-acv std ewyq-acw std euwac-fbzw euwan-kbzw euwap-kbzw euwab-kbzw euwyn-kbzw euwyp-kbzw euwyb-kbzw ewaq-daynn ewyq-daynn water Cooled scroll R-407C ewwp-kbwn Condenserless chiller scroll R-407C ewlp-kbwn Nomenclature for air-cooled b and C series: Nomenclature for air-cooled and C series: E W A D b Z X S E W A D 4 0 b Z X S Inverter 9 -: Inverter non-inverter -: Z: non-inverter inverter Z: inverter 0 Efficiency level 0 S: Efficiency Standard level S: X: Standard high X: p: high premium p: premium Sound level S: Sound Standard level S: l: Standard low l: R: low Reduced R: Reduced (s) op & op03 need to be added to meet Swedish national law 99: 6 (s) () op Impossible & op03 option need combination: to be added to opzh+opzl meet Swedish national law 99: 6 () () Impossible Not available option with option combination: opln opzh+opzl () Not available with option opln Description code ewad-bz ewyd-bz ewad~cz- ewwq~b- ewad~d- ewad~e- erad~e- ewwd~g-xs ewwd~g-ss ewld~g-ssewwd~i-xs ewwd-j-ss ewld~i-ss ewwd~fzxs ewad~c ewwd~i-ss ewld-j-ss Total heat recovery 0 Option (3) Option Option () Option Option Option Option (9) Option Total heat recovery circuit 0 Option (3) Option () Partial heat recovery 03 Option Option Option Option () Option Option Option Option Option Option Direct on line starter 04 wye delta starter (y - d) 05 std std std std std std std std std std soft starter 06 Option Option Option Option Option Option Option Option Option CF Heat pump version 07 Option Option Option (7) brine version 08 Option Option Option Option Option Option Option Option Option Option Option Option Double set point 0 std std std std std std std std std std std std Compressor thermal relays std Option Option Option Option Option Option Option Option Fans circuit breakers with thermal overload relays std std std std std Phase monitor 3 std std std std std std std std std std std std Inverter compressor starter 4 std std std CF Under / overvoltage control 5 Option Option Option Option Option Option Option Option Option Option Option Option energy meter 6 Option (3) Option Option Option Option Option Option Option Option Option Option Option Option Capacitors cosfi Option Option Option Option Option Option Option Option Option Option Current limit - display 9 Option Option Option Option Option Option Option Option Option Option std Option Option evaporator victaulic kit 0 std std std std () std std std std std std std evaporator flange kit Option Option () Option Option evaporator Marine waterbox VICTAULIC ( Pass) a Option evaporator marine waterbox victaulic ( step) Option evaporator marine waterbox victaulic (3 step) 3 Option evaporator Marine waterbox FLAngeD ( Pass) 4a Option evaporator marine waterbox flanged ( step) 4 Option evaporator marine waterbox flanged (3 step) 5 Option Condenser double flanges kit 6 Option Option Option Option (7) evaporator water side design pressure 0 bar 7 std std std std std std std evaporator water side design pressure 5 bar 8 Option Option Option 0 mm evaporator insulation 9 Option std Option Option () Option Option Option Option Option std std std Axial fans 00 pa lift 30 CF Axial fans 50 pa lift 3 CF 0mm condenser insulation 33 Option Option Option Option Option Option (7) Fan silent mode 34 std (4) Option Fans speed control device (phase cut on fan) 35 std (5) CF Condenser victaulic kit 36 Option Option Option Option std std (7) Condenser flange kit 37 Option Condenser Marine waterbox VICTAULIC ( Pass) 38a Option Condenser Marine waterbox VICTAULIC ( Passes) 38 Option Condenser Marine waterbox VICTAULIC (3 Passes) 39 Option Condenser Marine waterbox FLAngeD ( Pass) 40a Option Condenser Marine waterbox FLAngeD ( Passes) 40 Option Condenser Marine waterbox FLAngeD (3 Passes) 4 Option speedtrol (fan speed control device - on/off - up to -8 c) 4 Option Option (3) Option Option Option Condenser coil guards 43 Option Option Option Option Option Option evaporator area guards 44 Option Option CF Cu-cu condenser coil 45 Option Option Option Option Option Option Cu-cu sn condenser coil 46 Option Option Option Option Option Option Condenser water side design 6 bar 47 std std std std std (). Heat exchangers are placed in series. Please note the following option availability: - group : ewad80-00d-sl; ewad80-90d-sr; ewad0d-sx; ewad00-0d-hs - group : all other models group group Option 0 n/a std Option n/a Option Option 9 std Option 3. Option 4 is n/a for ewad-d-sx version 4. Option 56 is std for ewad80-00d-sl; ewad80-90d-sr; ewad00-0d-hs 5. One High pressure side manometer per circuit 6. * Low lift 8m high lift m (nominal condition) * Option 80/8 is n/a for ewad80-90d-sr; 78/79/80/8 is n/a for ewad-d-sx version 7. Option 99 is std for ewad-d-sx version 8. not available for smallest models 9. not available for high efficiency range 0. Tank delivered separately. not available for standard efficiency range 3. Only available for ewad~bz range 4. Fan silent mode is an option for ewyd~bzss 5. Only for ewyd~bzsl, option for ewyd~bzss 6. not available for ewyd~bz 7. not available for condenserless range 8. Only available for condenserless range * Option 76 is standard available for the versions with reduced / extra low sound level 8

9 noise & Head Pressure control lwe electrical refrigerant condenser buffer tank Low noise Inverter fans High esp fans High glycol Low glycol evaporator heater tape Main switch A / V meter Dual pressure relief valve suction stop valve Coil guards OPbT OPLn OPIF OPHF OPzH OPzL OP0 OP5 OP57 OP03 OP OPCg std std std std std std std std () std (s) () std (s) Description code ewad-bz ewyd-bz ewad~cz- ewwq~b- ewad~d- ewad~e- erad~e- ewwd~g-xs 9 ewwd~g-ss ewld~g-ssewwd~i-xs ewwd~i-ss ewld~i-ss ewwd~fzxs ewad~c ewwd-j-ss ewld-j-ss Condenser water side design bar 48 Option Alucoat fins coil 49 Option Option Option Option Option Option Cu-ni 90-0 condenser tubes 50 Option Option Option Option Condenser pass (dt 4-8 c) 5 std (9) Option Condenser passes (dt 4-8 c) 5 std () std (7) Condenser passes (dt 9-5 c) 53 Option (9) std Condenser 3 passes 53b Option Condenser 4 passes 54 Option () water pressure differential switch on condenser 55 Option std water pressure differential switch on evaporator 56 Option (4) Option Option std Option (7) evaporator electric heater 57 std std Option std std std evaporator flow switch 58 Option Option Option Option Option Option Option Option Option Option Option std Condenser flow switch 59 Option Option Option electronic expansion device 60 std std std std std std std std std std std std Discharge line shut off valve 6 std std Option std std std Option Option std std suction line shut off valve 6 std Option Option std std std std std Option Option Option std High pressure side manometers 63 Option Option std Option (5) Option Option std (9) std std std std Option std Low pressure side manometers 64 std std std Option Additional capacity reduction steps 65 Ambient outside temperature sensor and set-point reset 67 std Option std std std Hour run meter 68 std std std std std std std () std std std std std std general fault contactor 69 std std std std std std std std std std std std std Container kit 7 Option Option Option Option Option Option Option Option Option Fork-lift kit 7 Option Option Option wooden box packing 74 Rubber anti vibration mount 75 Option Option Option Option Option Option Option Option Option Option Option Option Option sound proof system* 76 Option Option Option Option Option Option Option spring anti vibration mount 77 Option Option Option Option Option Option One centrifugal pump (low lift) 78 Option Option Option Option Option One centrifugal pump (high lift) 79 Option Option Option Two centrifugal pumps (low lift) 80 Option Option Option (6) Option (8) Option Two centrifugal pumps (high lift) 8 Option Option (6) Option (8) witness test 8 CF CF CF CF CF CF CF CF CF CF external tank without cabinet (500 l) 83 Option (0) Option Option external tank without cabinet (000 l) 84 Option (0) Option Option external tank (500 l) with cabinet RAL Option (0) Option Option external tank (000 l) with cabinet RAL Option (0) Option Option Acoustic test 89 CF CF CF CF CF CF CF CF CF CF set-point reset, demand limit and alarm from external device 90 Option std std Option std std std std std std std std Option Double pressure relief valve with diverter 9 Option Option std Option Option Option Option Option Option Option std Option Option Low ambient kit for circuit 93 Low ambient kit for circuits 94 Compressor circuit breakers 95 Option Option Option Option Option Option Fans circuit breakers 96 std std std std Main switch interlock 97 std (6) std std std std std emergency stop 98 Option std std Fan speed regulation 99 std (6) Option Option (7) Option Refrigerant recovery tank 00 Option Option evaporator right water connection 0 Option Option ground fault relay 0 Option Option CF evaporator pass 03 std std evaporator passes 03a Option evaporator 3 passes 03b std evaporator Double Flange kit 04 Liquid receiver 05 Option Option Option (8) Rapid restart 0 Option

10 accessories portfolio RTFOLIO Air-cooled Chillers ewa/yq009-0acv3 ewa/yq009-03acw euwac-fbzw euwa/y*-kbzw ewa/yq-dayn ewad~d ewa(y)d~bz ewad~c- ewad Panels ekdssp ekdssp-s*** ekddsp ekpwpro ekpwprom Serial Cards & Comm. Modules ekac0c ekacpg ekac00a ekac00j ekacbac ekaclon ekaclonp ekacrs3 ekacweb ekacbacmstp ekacbaccert ekcm00j ekcmlon ekcmbacmstp ekcmbacip LON Gateway eklonpg Other Systems & Accessories ekclws ekcon ekconusb ekmodem ekgsmod ekrphb ekrupcj ekrupck ekrupcs ekpvj ekpwproext ekgwweb ekgwmodem ekbnpg ekbmsbna ekbmsmba ekrumca ekrupc ekrupg ehmc*av00 ehmc*av080 Gauges ekgau5/8ka (5-8) ekgau0/ka (0-) ekgau6ka (6) ekgau0/4ka (0-4) Soft starter ekss Buffer tank ekbt Waterpipe kit ekgn0 (080-0) ekgn60 (ewaq40-60dayn & ewyq30-50dayn) * To install ekrumca => ekac0c needs to be installed on the unit. * ekac0c allows direct connection to MODbUs bms system * To install eklonpg & ekbnpg => ekacpg needs to be Type: FwM-DT/DF, FwL-DT/DF, FwV-DT/DF Description fwv fwl fwm Additional single row heat exchanger esrh0a6 esrh03a6 esrh06a6 esrh0a6 x x x electric heater eeh0a6 eeh0a6 eeh03a6 eeh06a6 eeh0a6 x x x -pipe 3-way valve emv03a6 emv06a6 emv0a6 x x x 4-pipe 3-way valve e4mv03a6 e4mv06a6 e4mv0a6 x x x Fan stop thermostat yfsta6 x x x Air intake & discharge grille eaidf0a6 eaidf03a6 eaidf06a6 eaidf0a6 - - x supporting feet esfv06a6 esfv0a6 x - x supporting feet + grille esfvga6 esfvg3a6 esfvg6a6 esfvg0a6 x - - Fresh air intake efaa6 efa3a6 efa6a6 efa0a6 x - - Rear panel erpva6 erpv3a6 erpv6a6 erpv0a6 x x - Control electromechanical ecfwmb6 0 x x x electronic controller FweCA, FweCA, FweC3A x x x Master slave option epimsb6 x x x Type: Fwb-bT Description Additional heat exchanger eah04a6 eah07a6 eah0a6 3-way valve add. h/e emv307a6 emv30a6 3-way valve cooling h/e Factory mounted -way valve add. h/e emv07a6 emv0a6 -way valve cooling h/e Factory mounted electric Heater Factory mounted Fan stop thermostat yfsta6 Power interface - - epib6 Master slave interface epimsb6 FweCA Type: FwD-AT/ Description electric heater: electric heater: -pipe 3-way v 4-pipe 3-way v Vertical Drainp Horizontal Dra Fan stop therm Fresh air intake

11 water-cooled Chillers Centrifugals ~Cz- ewwp-kbwn ewlp-kbwn eww(l)d~g- eww(l)d~i- ewwd~bj ewwq~b- eww(l)d~j- ewwd~fzxs DwsC & DwDC (04-045) (0-030) installed on the unit. AF small edeh04a6 edehs06a6 edehs0a6 edehsa6 edehs8a6 () big edeh04a6 edehb06a6 edehb0a6 edehba6 edehb8a6 alve edmv04a6 edmv0a6 edmva6 edmv8a6 () alve ed4mv04a6 ed4mv0a6 xedmva6 x edmv8a6 an eddpv0a6 eddpv8a6 inpan eddph0a6 eddph8a6 ostat yfsta6 edmfa04a6 edmfa06a6 edmfa0a6 edmfaa6 edmfa8a6 TyPe Description FwT FwC-bT/bF FwF-bT/bF standard wired remote control MeRCA - - simplified wired remote control src-cob - - simplified wired remote control src-hpb - - wireless control for cooling only wrc-cob - - wireless control for heat pump wrc-hpb - - Decoration Panel (RAL grey sealings) 4-way blow - - byfq60b Decoration Panel - standard (RAL grey sealings) Round flow - bycq40cw Decoration Panel - white (RAL white sealings) Round flow - bycq40cww sealing member of air discharge outlet - kdbhq55c40 kdbh44ba60 Panel spacer - - kdbq44b60

12 Daikin Europe N.V. About Daikin Daikin has a worldwide reputation based on 85 years experience in the successful manufacture of high quality air conditioning equipment for industrial, commercial and residential use. Daikin quality Daikin s much envied quality quite simply stems from the close attention paid to design, production and testing as well as aftersales support. To this end, every component is carefully selected and rigorously tested to verify its contribution to product quality and reliability.

13 Environmental Awareness Daikin and the environment Air conditioning systems provide a significant level of indoor comfort, making possible optimum working and living conditions in the most extreme climates. In recent years, motivated by a global awareness of the need to reduce the burdens on the environment, some manufacturers including Daikin have invested a geat deal in limiting the negative effects associated with the production and the operation of air conditioners. Hence, models with energy saving features and improved eco-production techniques have seen the light of day, making a significant contribution to limiting the impact on the environment. Smart control brings comfort and reduces energy consumption Inverter technology used in the air cooled Mini Chiller (EWAQ-AC & EWYQ-AC), the heat pump inverter EWYD-BZ and the cooling only inverter EWAD-CZ, allows more precise control of the leaving water condition in function of the load. This leads to energy savings and high comfort levels, ensuring it is never too cool or too hot. This is a major advantage over standard fixed speed models, which use on/off cycling of the compressor, creating greater fluctuations in control conditions. This technology has now also been introduced into our water cooled range with the centrifugal inverter DWSC/DWDC series. 3

14 Inverter technology Water temperature Temperature remains stable Set temp. Shorter start-up Chiller without Inverter Chiller with Inverter Time Inverter technology offers improved levels of comfort: Energy efficient: continuous matching of load requirement Start-up time is reduced by /3 Less frequent start/stop cycles Reduced sound levels High EER /COP values 4

15 Inverter technology for higher efficiency Both inverter drive (ID) and variable frequency drive (VFD) are terms used to describe a piece of electrical hardware that is used to start, stop, and control the speed of an electric motor. When fitted to a single screw compressor or scroll compressor, an inverter allows it to continuously adapt the cooling capacity to the requirement of the building load by controlling the speed of the compressor motor. Traditional systems using electric motors running at full speed even when unloaded waste electricity and with most building energy being consumed by HVAC operations, possible savings are important. With soaring energy prices and global warming concerns, our variable frequency drives for HVAC compressors, pumps, fans and motors are a major efficiency improvement as well as an energy saver and these combine to reduce costs. The full range of Daikin chillers now come with inverters already fitted or with an inverter alternative. Principal benefits Energy efficient: displacement power factor always > 0.95 Usually the power factor of a motor progressively worsens with the decrease of the power output. However thanks to the inverter, there is no need for additional power factor correction capacitors as the power factor is always > 0.95 and there are no power surges and so costs are constrained. Quick start-up: start up time reduced by /3 The ability to vary the output power in direct relation to the cooling requirements of the system by allowing compressor boosts, gives the inverter chiller a reduced start-up-tooperating-capacity making it possible to achieving building comfort conditions in /3 less time than with conventional systems. Less frequent start/stop cycles and low starting current The inverter technology ensures fewer start/stop cycles as well as ensuring that the start-up current is always lower than current absorbed in the maximum operating conditions (FLA). This generates obvious cost savings. Seasonal quietness: reduced sound levels Low sound levels in partial load conditions are achieved by the variation of compressor frequency, thus ensuring the minimum sound levels at all times. 5

16 Reliable and Efficient Whatever the requirements of the customer, large systems requiring constant capacity or smaller systems for flexibility, Daikin always provides a reliable and efficient solution. THE Swing compressor: swing Swing bush The Scroll compressor for controlled capacity: scroll Ref. Gas The Mini Chiller series EWAQ ACV3 & EWYQ ACV3 are equipped with a swing compressor. This innovative design by Daikin with fewer moving parts allows smoother more reliable operation with low vibration and low noise levels. The high efficiency motor reduces energy consumption resulting in energy cost savings. Innovative frictionless centrifugal compressor : centrifugal Permanent Magnet Direct Drive Motor Motor and bearing control (the electronics) Inverter speed control The piston which the blade and the roller unified stage centrifugal compressor Pressure and temperature sensors Inlet Guide Vanes Being compact, the Daikin scroll compressor is used with R-407C and R-40A to provide constant reliability and high efficiency right throughout its service life. Designed for small and medium capacities, the scroll compressors are used with air cooled and water cooled chillers within the range of capacities between 9. and 8kW. Characteristics : Compact, simple yet robust design Absence of valves and oscillating connecting mechanisms providing maximum reliability Constant compression guaranteeing low energy consumption Increased compression efficiency thanks to the absence of volumetric re-expansion Low sound level Low starting current The innovative frictionless centrifugal compressor has an integrated VFD as well as magnetic bearings and delivers high levels of unit efficiency and reliability. The compressor s one moving part the rotor shaft and impellers is powered by the permanent magnet direct drive motor and kept levitated by a digitally controlled magnetic bearing system. This reduction in moving parts significantly increases unit reliability and reduces maintenance costs. As the condensing temperature and/or cooling load reduces, the speed of rotation reduces and movable inlet guide vanes, activated by the step motor, redirect gas flow into the first stage impeller once the compressor has reached its minimum speed. This delivers increased efficiency and cost savings during part-load operation. 6

17 standard anti-corrosion treatment As standard, condensers for air cooled chillers are given anti-corrosion treatment. This treatment significantly increases resistance to acid rain and saline corrosion. Depending on the capacities and models, treatments are of the following type: Example of acrylic treatment Acrylic treatment (Daikin ref PE) The aluminium fins are coated with an acrylic resin and a hydrophilic film. Epoxy Treatment The aluminium fins are black epoxy coated. The single screw STEPLESS compressor for high capacit y: 7 screw 0. Casing. Slide valve 3. Screw rotor 4. Bearing 5. Motor 6. Gate rotor nd stage oil separator 8. Demister (oil separator) 9. Refrigerant suction 0. Refrigerant discharge. Compressor terminal + CTP. Stepper Motor The heart of the larger Daikin chillers is a semi hermetic single screw compressor, designed, tested and manufactured in Daikin s own laboratories, in order to meet the highest capacity, performance and maintenance specifications. This compressor has been especially developed for operation with R-40A, R-34a or R-407C refrigerant, guaranteeing unequalled reliability and many years of efficient operation. The bearing life is 00,000hrs with inspection and maintenance intervals every 40,000hrs. Characteristics : optimal performance through stepless capacity control in function of the chilled water temperature. The unit capacity is infinitely variable from 30-00% on single circuit units and 5-00% on dual circuit units. Compact, simple yet robust construction. Using a main single screw and two gate rotors, axial and radial forces are balanced thanks to the symmetrical compression guaranteeing low bearing loads. Renowned for its low noise levels the double walled casing design and integrated oil separator, add to the attenuation effect. Gate rotors made of polymer material result in closer tolerances with main screw and reduced friction greatly improving compressor efficiency and lifetime. No oil pump necessary lubrication based on differential pressure principle. Easy access to both compressor and safety devices Star delta starter with low starting current as standard 7 7

18 Air Cooled In the chilled water market, chillers of the air cooled type are most frequently used. Out of its wide range of chillers in cooling only or heat pump version, with or without integrated hydronic components, Daikin always offers you a chiller fitting your application needs. TABLE OF CONTENTS EWAQ-ACV3 & EWAQ-ACW 0 EWYQ-ACV3 & EWYQ-ACW euwac-fbzw 4 Euwa*-kbzw 6 Euwy*-kbzw 8 EWaQ-dayn 30 EWyQ-dayn 3 ewad-e-ss 34 EWAD-E-SL 36 EWad-d-ss 38 EWad-d-sL 40 EWad-d-sR 4 EWad-d-sx 44 EWAD-d-xs 46 ewad-d-xr 48 ewad-d-hs 50 ewad-bzss-sl 5 ewad-bzxs/xl/xr 54 ewyd-bzss 56 EWyd-bzsL 58 EWad-c-ss/sL 60 ewad-c-sr 6 ewad-c-xs/xl 64 ewad-c-xr 66 ewad-c-ps/pl 68 ewad-c-pr 70 ewad-czxs/xl 7 ewad-czxr 74 8

19 Daikin has taken great care to match major chiller components and refrigerant combinations to a point where high efficiency ranges of technically advanced and closely optimised air and water cooled units are now widely available for use with R-40A, R-407C and R-34a refrigerants. swing scroll screw centrifugal Air cooled chiller Chillers t Expansion vessel Buffer Tank Evaporator t To fan coil units t Temperature sensor. Filter 3. Shut-off valve 4. Pump 5. Pressure port 6. Flow switch 7. Air purge 8. Pressure gauge 9. Balancing valve 0. Drain valve. Charging valve. Safety valve

20 EWAQ-aC Air cooled mini chiller inverter Strengths Optimised for use with R-40A Inverter controlled swing compressor (size ) - Precise temperature control Inverter controlled scroll compressor (size 009-0) Low operating sound level Easy plug and play installation Wide operating range Integrated hydronics Options (factory mounted) Evaporator heater tape Digital controller s w i n g s c r o l l OPTION KIT Digital Input/Output PCP (size only) CONTROL Leaving water control Available Inputs Voltage free contact: - ON/OFF Schedule timer: - ON/OFF - Silent operation 0

21 EWAQ ACV3 + EWAQ009-0ACV3 / EWAQ009-03ACW Cooling only Capacity class EWAQ-ACV3 EWAQ-ACW Cooling capacity Nom. kw Power input Cooling Nom. kw EER ESEER Dimensions Unit HeightxWidthxDepth mm 805x,90x360,435x,48x38 Weight Unit kg Water heat Type Brazed plate exchanger Water volume l -.0 Nominal water Cooling l/min flow Air heat exchanger Type Tube type Hi-XSS Pump Nominal ESP unit Cooling kpa Hydraulic components Expansion vessel Volume l Fan Air flow rate Cooling Nom. m³/min Fan motor Speed Cooling Nom. rpm Steps - 8 Sound power level Cooling Nom. dba Sound pressure Cooling Nom. dba level Night quiet mode Cooling dba Compressor Type Hermetically sealed swing compressor Hermetically sealed scroll compressor Operation range Water side Cooling Min.~Max. CDB 5~0 5~ Air side Cooling Min.~Max. CDB 0~43 0~46 Refrigerant Type R-40A Charge kg.7.95 Control Electronic expansion valve Circuits Quantity Water circuit Piping connections diameter inch - G 5/4" (female) Piping inch - 5/4" Piping Water heat exchanger inlet / outlet " MBSP - connections Water heat exchanger drain Hose nipple /" FBSP - Power supply Phase / Frequency / Voltage Hz / V ~ / 50 / 30 3N~ / 50 / 400

22 EWYQ-AC Air cooled mini chiller inverter Strengths Optimised for use with R-40A Inverter controlled swing compressor (size ) - Precise temperature control Inverter controlled scroll compressor (size 009-0) Low operating sound level Easy plug and play installation Integrated hydronics Wide operating range OPTIONS (factory mounted) Evaporator heater tape Digital controller s w i n g s c r o l l OPTION KIT Digital Input/Output PCP (size only) CONTROL Leaving water control Setpoint in heating & cooling AVAILABLE INPUTS Voltage free contact: - ON/OFF - Cooling/Heating changeover Schedule timer: - ON/OFF - Dual setpoint - Silent operation

23 EWYQ ACV3 + EWYQ009-0ACV3/EWYQ009-03ACW Heating & Cooling Capacity class EWYQ-ACV3 EWYQ-ACW Cooling capacity Nom. kw Heating capacity Nom. kw Power input Cooling Nom. kw Heating Nom. kw EER COP ESEER Dimensions Unit HeightxWidthxDepth mm 805x,90x360,435x,48x38 Weight Unit kg Operation weight kg 04 - Water heat Type Brazed plate exchanger Water volume l -.0 Nominal water Cooling l/min flow Heating l/min Air heat exchanger Type Tube type Hi-XSS Pump Nominal ESP unit Cooling kpa Hydraulic components Expansion vessel Volume l 6 0 Fan Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Fan motor Speed Cooling Nom. rpm Heating Nom. rpm Steps - 8 Sound power level Cooling Nom. dba Heating Nom. dba - 64 Sound pressure Cooling Nom. dba level Heating Nom. dba Night quiet mode Cooling dba Heating dba Compressor Type Hermetically sealed swing compressor Hermetically sealed scroll compressor Operation range Water side Cooling Min.~Max. CDB 5~0 5~ Heating Min.~Max. CDB 5~50 5~50 Air side Cooling Min.~Max. CDB 0~43 0~46 Heating Min.~Max. CDB -5~5-5~35 Refrigerant Type R-40A Charge kg.7.95 Control Electronic expansion valve Circuits Quantity Water circuit Piping connections diameter inch - G 5/4" (female) Piping inch - 5/4" Piping Water heat exchanger inlet / outlet " MBSP - connections Water heat exchanger drain Hose nipple /" FBSP - Power supply Phase / Frequency / Voltage Hz / V ~ / 50 / 30 3N~ / 50 / 400 3

24 EUWAC-FBZW Air cooled chiller with centrifugal fan Strengths Optimised for use with R-407C Daikin scroll compressor Electronic DDC controller Standard phase sequence controller Maximum external static pressure (ESP): 50Pa Pressure gauges Standard operation range down to -0 C Regulating switch Water inlet or outlet temperature control Input contacts/available outputs Input: on/off (per circuit), pump/flow switch Outputs: compressor operation, summary alarm, pump relay contact Compatible with hydraulic module µc² SE controller Options (factory mounted) Chilled water temperature down to - 5 C (OPZH) or -0 C (OPZL) * OPZH: Option LWE high glycol OPZL: Option LWE low glycol Accessories (kit) Address card for connection to BMS or remote user interface (EKAC0C) Remoted installed user interface (EKRUMCA) * To install EKRUMCA -> EKAC0C needs to be installed on the unit Control Water inlet temperature control Available inputs / outputs Input ON / OFF (per circuit) Pump / flow switch Output Compressor operation Summary alarm Pump relay contact s c r o l l µc SE 4

25 EUWAC8FBZW Cooling only Capacity class Cooling capacity Nom. kw Capacity steps % 00-0 Power input Cooling Nom. kw EER Dimensions Unit HeightxWidthxDepth mm,345x856x630,90x,80x630,395x,330x630 Weight Unit kg Operation weight kg Water heat Type Brazed plate, one per circuit exchanger - Minimum water volume in the system l 0 53 evaporator Water flow rate Nom. l/min Nominal water Cooling Heat kpa pressure drop exchanger Model Type AC70-4 AC70-34 AC70-40 Quantity Air heat exchanger Type Cross fin coil/hi-x tubes and PE coated waffle louvre fins Fan Air flow rate Nom. m³/min Sound power level Cooling Nom. dba Compressor Type Hermetically sealed scroll compressor Operation range Water side Cooling Min.~Max. CDB -0 (OPZL) ~ Air side Cooling Min.~Max. CDB -0 ~ 43 Refrigerant Type R-407C Control Thermostatic expansion valve Circuits Quantity Refrigerant circuit Charge kg Piping Evaporator water inlet/outlet FBSP " connections Evaporator water drain Field installation Power supply Phase / Frequency / Voltage Hz / V 3N~ / 50 / 400 5

26 EUWA*-kBZW Air cooled chiller Strengths Optimised for use with R-407C Daikin scroll compressor Reduced installation time thanks to integrated pump and and/or buffer tank Possibility for a 00l buffer tank Low operating sound level Easy maintenance Main switch Water flow switch 3 different design options available: - EUWAN chiller without integrated hydraulic module ; - EUWAP chiller with integrated hydraulic module (pump, expansion vessel, hydraulic components) ; - EUWAB chiller with integrated hydraulic module (buffer tank, pump, expansion vessel, hydraulic components) µc² SE controller Options (factory mounted) Chilled water temperature down to - 5 C (OPZH) or -0 C (OPZL) High ESP fans (50Pa) (OPHF) Pump size up (OPHP) * OPZH: Option LWE high glycol OPZL: Option LWE low glycol Accessories (kit) Refrigerant pressure gauges (EKGAU5/8/0//6/0/4KA) 00l buffer tank (EKBT, see EKBT page in this catalogue) Soft starter kit (EKSS) Address card for connection to BMS or remote user interface (EKAC0C) Remote installed user interface (EKRUMCA) * To install EKRUMCA -> EKAC0C needs to be installed on the unit Control Water inlet temperature control Available inputs / outputs Input Remote ON / OFF Pump contact Output Compressor operation Summary alarm Pump relay contact Hydraulic CIRCUIT COMPONENTS s c r o l l µc SE Air purge Safety valve Pressure port Buffer tank Flow switch Water Pressure gauge Expansion vessel Drain Water flow adjusting valve Pump 6

27 EUWA*6KBZW EUWAN: Scroll compressor Main isolator switch Water flow switch Filter Condenser protection grille All year operation EUWaP = EUWaN + Pump Expansion vessel Adjusting valve Drain Water pressure gauge Pressure relief valve EUWaB = EUWaP + Buffer tank Cooling only Capacity class N5 P5 B5 N8 P8 B8 N0 P0 B0 N P B N6 P6 B6 N0 P0 B0 N4 P4 B4 Cooling capacity Nom. kw Capacity steps % Power input Cooling Nom. kw EER Dimensions Unit HeightxWidthxDepth mm,30x,90x734,450x,90x734,3x,580x734,54x,580x734 Weight Unit kg Operation weight kg Water heat Type Brazed plate exchanger Water volume l Nominal water flow Cooling l/min Nominal water Cooling Heat kpa pressure drop exchanger Air heat exchanger Type Cross fin coil/hi-x tubes and PE coated waffle louvre fins Hydraulic components Expansion vessel Volume l Fan group Air flow rate Cooling Nom. m³/min 60 (per fans) 70 (per fans) Fan group Air flow rate Cooling Nom. m³/min - 70 (per fans) Sound power level Cooling Nom. dba Compressor Type Hermetically sealed scroll compressor Operation range Water side Cooling Min.~Max. CDB -0 (OPZL) ~ 5 Air side Cooling Min.~Max. CDB -5 ~ 43 Refrigerant Type R-407C Control Thermostatic expansion valve Circuits Quantity Refrigerant circuit Charge kg Refrigerant circuit Charge kg Water circuit Piping connections diameter inch G "/4 (male) " male Piping inch -/4" - Power supply Phase / Frequency / Voltage Hz / V 3N~ / 50 / 400 7

28 EUWY*-kBZW Air cooled chiller Strengths Optimised for use with R-407C Daikin scroll compressor Reduced installation time thanks to integrated pump and/or buffer tank Possibility for a 00l buffer tank Low operating sound level Easy maintenance Main switch Water flow switch 3 different design options available: - EUWYN chiller without integrated hydraulic module; - EUWYP chiller with integrated hydraulic module (pump, expansion vessel, hydraulic components); - EUWYB chiller with integrated hydraulic module (buffer tank, pump, expansion vessel, hydraulic components) µc² SE controller Options (factory mounted) Chilled water temperature down to - 5 C (OPZH) or -0 C (OPZL) High ESP fans (50Pa) (OPHF) Pump size up (OPHP) * OPZH: Option LWE high glycol OPZL: Option LWE low glycol Accessories (kit) Refrigerant pressure gauges (EKGAU5/8/0//6/0/4KA) 00l buffer tank (EKBT, see EKBT page in this catalogue) Soft starter kit (EKSS) Address card for connection to BMS or remote user interface (EKAC0C) Remote installed user interface (EKRUMCA) * To install EKRUMCA -> EKAC0C needs to be installed on the unit Control Water inlet temperature control Available inputs / outputs Input Remote ON / OFF Pump contact Remote cool / heat selection Output Compressor operation Summary alarm Pump relay contact s c r o l l µc SE 8

29 EUWY*6KBZW EUWYN: Standard equipment Scroll compressor Main isolator switch Water flow switch Filter Condenser protection grille. All year operation EUWYP = EUWYN + Pump Expansion vessel Adjusting valve Drain Water pressure gauge Pressure relief valve EUWYB = EUWYP + Buffer tank Heating & Cooling Capacity class N5 P5 B5 N8 P8 B8 N0 P0 B0 N P B N6 P6 B6 N0 P0 B0 N4 P4 B4 Cooling capacity Nom. kw Heating capacity Nom. kw Capacity steps % Power input Cooling Nom. kw Heating Nom. kw EER COP Dimensions Unit HeightxWidthxDepth mm,30x,90x734,450x,90x734,3x,580x734,54x,580x734 Weight Unit kg Operation weight kg Water heat Type Brazed plate exchanger Water volume l Nominal water Cooling l/min flow Heating l/min Nominal water Cooling Filter kpa pressure drop Heating Filter kpa Air heat exchanger Type Cross fin coil/hi-x tubes and PE coated waffle louvre fins Hydraulic components Expansion vessel Volume l Fan group Air flow rate Cooling Nom. m³/min 60 (per fans) 70 (per fans) Fan group Air flow rate Cooling Nom. m³/min - 70 (per fans) Sound power level Cooling Nom. dba Compressor Type Hermetically sealed scroll compressor Operation range Water side Cooling Min.~Max. CDB -0(OPZL) ~ 0 Heating Min.~Max. CDB 35 ~ 50 Air side Cooling Min.~Max. CDB -5 ~ 43 Heating Min.~Max. CDB -0 ~ Refrigerant Type R-407C Control Thermostatic expansion valve Circuits Quantity Refrigerant circuit Charge kg Refrigerant circuit Charge kg Water circuit Piping connections diameter inch G "/4 (male) " male Piping inch -/4" " Power supply Phase / Frequency / Voltage Hz / V 3N~ / 50 / 400 9

30 EWAQ-dayn Air cooled chiller, multiple scroll Strengths Optimised for use with R-40A refrigerant Multiple compressors per circuit Reliable and efficient scroll with high EER values Anti-corrosion treated aluminium coils Low operating sound level Easy plug and play installation Fans protected against abnormal operation (4-8 fans depending on unit size) Safety valves in each circuit Electronic circuit breakers Electronic expansion valve True dual plate brazed plate heat exchanger All hydronics can be accessed easily from 3 sides (no surrounding cabinet) Separate switchbox for easy access Compressors and controls at unit side Increased reliability via independent refrigerant circuits (EWAQ30-60DAYN) Double circuit heat exchanger (from >00 kw) Non hermetic filter/dryer Daikin Pcaso controller with user friendly and powerful LCD interface PCASO s c r o l l Options (factory mounted) Single pump contactor (OPSC) Twin pump contactor (OPTC) Single pump (OPSP) Twin pump (OPTP) ( pump casing, dual motor) High ESP pump (OPHP) (single pump only) Buffer tank (OPBT) Inverter fans (OPIF) (Not available with option OPLN) Glycol 0 C / -0 C (OPZL) Evaporator heater tape (OP0) Option valves (discharge, liquid line and suction stop valve: OP) A-meter / V-meter (OP57) Low Noise (OPLN) (=OPIF + compressor housing) Condenser protection grills (OPCG) Accessories (kit) Gateway for LON (EKLONPG) Gateway for BACNET (EKBNPG) Address card (EKACPG) Remote user interface (EKRUPG) 30

31 EWAQ30,50DAYN Cooling only Capacity class Cooling capacity Nom. kw Capacity steps % /9- / /50/57-7/ /50/56-7/ Power input Cooling Nom. kw EER ESEER Dimensions Unit HeightxWidthxDepth mm,3x,000x,566,3x,000x,63,3x,000x3,08,3x,000x4,850 Weight Unit kg,350,400,500,550,800,850 3,50 3,50 Operation weight kg,365,45,57,569,85,877 3,89 3,9 Water heat Type Brazed plate exchanger Nominal water flow Cooling l/min Nominal water Cooling Total kpa pressure drop Air heat exchanger Type Cross fin coil/hi-xss tubes and poly ethylene coated waffle fins Fan Air flow rate Nom. m³/min ,90,600 Speed rpm Sound power level Cooling Nom. dba Compressor Type Scroll compressor Operation range Water side Cooling Min.~Max. CDB -0 (OPZL) ~ 5 Air side Cooling Min.~Max. CDB -5 ~ 43 Refrigerant Type R-40A Charge kg Control Electronic expansion valve Circuits Quantity Piping Water heat exchanger inlet / outlet 3" OD 3" connections Water heat exchanger drain /"G Power supply Phase / Frequency / Voltage Hz / V 3~ / 50 / 400 3

32 EWyQ-dayn Air cooled chiller, multiple scroll STRENGTHS Optimised for use with R-40A refrigerant Multiple compressors per circuit Reliable and efficient scroll with high EER values Anti-corrosion treated aluminium coils Low operating sound level Easy plug and play installation Fans protected against abnormal operation (4-8 fans depending on unit size) Safety valves in each circuit Electronic circuit breakers Electronic expansion valve True dual plate brazed plate heat exchanger All hydronics can be accessed easily from 3 sides (no surrounding cabinet) Separate switchbox for easy access Compressors and controls at unit side Increased reliability via independent refrigerant circuits (EWYQ30-50DAYN) Double circuit heat exchanger (from >00 kw) Non hermetic filter/dryer Daikin Pcaso controller with user friendly and powerful LCD interface PCASO s c r o l l OPTIONS (factory mounted) Single pump contactor (OPSC) Twin pump contactor (OPTC) Single pump (OPSP) Twin pump (OPTP) ( pump casing, dual motor) High ESP pump (OPHP) (single pump only) Buffer tank (OPBT) Inverter fans (OPIF) (Not available with option OPLN) Glycol 0 C / -0 C (OPZL) Dual pressure relief valve (OP03) Evaporator heater tape (OP0) Option valves (discharge, liquid line and suction stop valve: OP) A-meter / V-meter (OP57) Low Noise (OPLN) (=OPIF + compressor housing) Condenser protection grills (OPCG) ACCESSORIES (kit) Gateway for LON (EKLONPG) Gateway for BACNET (EKBNPG) Address card (EKACPG) Remote user interface (EKRUPG) 3

33 EWYQ30,50DAYN Heating & Cooling Capacity class Cooling capacity Nom. kw Heating capacity Nom. kw Capacity steps % /9-43/50/57-7/79-00 /8-44/50/56-7/ Power input Cooling Nom. kw Heating Nom. kw EER COP ESEER Dimensions Unit HeightxWidthxDepth mm,3x,000x,566,3x,000x,63,3x,000x3,08,3x,000x4,850 Weight Unit kg,400,450,550,600,850,900 3,00 3,300 Operation weight kg,45,465,567,69,875,97 3,39 3,34 Water heat Type Brazed plate, one per unit exchanger Nominal water Cooling l/min flow Heating l/min Nominal water Cooling Total kpa pressure drop Heating Total kpa Air heat exchanger Type Cross fin coil/hi-xss tubes and poly ethylene coated waffle fins Fan Air flow rate Nom. m³/min ,90,600 Speed rpm Sound power level Cooling Nom. dba Compressor Type Scroll compressor Operation range Water side Cooling Min.~Max. CDB -0 (OPZL) ~ 5 Water side Heating Min.~Max. CDB 5 ~ 50 Air side Cooling Min.~Max. CDB -5 ~ 43 Air side Heating Min.~Max. CDB -0 ~ Refrigerant Type R-40A Control Electronic expansion valve Circuits Quantity Refrigerant circuit Charge kg Refrigerant circuit Charge kg Piping Water heat exchanger inlet / outlet 3" OD 3" connections Water heat exchanger drain /"G Power supply Phase / Frequency / Voltage Hz / V 3~ / 50 /

34 EWAD-E-SS Air cooled chiller, standard efficiency, standard sound STRENGTHS Wide capacity range: 0 sizes to cover a range from 0 to 43 kw One refrigerant circuit with single screw compressor Compact design with brazed plate heat exchanger Large operation range (ambient temperature down to -8 C) Water supply down to -5 C MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communication STANDARD AVAILABLE Wye delta starter (y - d) Double setpoint Fans circuit breakers with thermal overload relays Phase monitor Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Low pressure side manometers Ambient outside temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Fans circuit breakers Main switch interlock s c r e w MicroTech III OPTIONS (factory mounted) Total heat recovery Partial heat recovery Soft starter Brine version Compressor thermal overload relays Under/Over voltage control Energy meter Capacitors for power factor correction Current limit - display 0 mm evaporator insulation Speedtrol Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount Single pump (low or high lift) Twin pump (low or high lift) - (Not available on sizes 00 and 0) Double pressure relief valve with diverter Compressor circuit breakers External tank with or without (500 and 000 l) 34

35 EWAD00-0E-SS ACCESSORIES Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM00J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) Cooling only Capacity class Cooling capacity Nom. kw Capacity control Method Stepless Minimum capacity % 5 Power input Cooling Nom. kw EER ESEER Dimensions Unit HeightxWidthxDepth mm,73x,9x,65,73x,9x3,065,73x,9x3,965,3x,36x3,070 Weight Unit kg,684,86,086,99 Operation weight kg,699,88,6,963 Water heat Type Plate to plate exchanger Water volume l Nominal water flow Cooling l/s Nominal water Cooling Heat kpa pressure drop exchanger Air heat exchanger Type High efficiency fin and tube type with integral subcooler Fan Air flow rate Nom. l/s 0,9 0,575 6,383 5,863,844,50 3,767 3,75 Speed rpm 90 Sound power level Cooling Nom. dba Sound pressure level Cooling Nom. dba Compressor Type Semi-hermetic single screw compressor Operation range Water side Cooling Min.~Max. CDB -5~5 Air side Cooling Min.~Max. CDB -8~48 Refrigerant Type R-34a Charge kg Circuits Quantity Piping connections Evaporator water inlet/outlet 3" Power supply Phase / Frequency / Voltage Hz / V 3~ / 50 /

36 EWAD-E-SL Air cooled chiller, standard efficiency, low sound STRENGTHS Wide capacity range: 0 sizes to cover a range from 97.9 kw to 398 kw One refrigerant circuit with single screw compressor Low operating sound level Compact design with brazed plate heat exchanger Large operation range (ambient temperature down to -8 C) Water supply down to -5 C MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communication STANDARD AVAILABLE Wye delta starter (y - d) Double setpoint Fans circuit breakers with thermal overload relays Phase monitor Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Low pressure side manometers Ambient outside temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Fans circuit breakers Main switch interlock s c r e w MicroTech III OPTIONS (factory mounted) Total heat recovery Partial heat recovery Soft starter Brine version Compressor thermal overload relays Under/Over voltage control Energy meter Capacitors for power factor correction Current limit - display 0 mm evaporator insulation Speedtrol Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount Single pump (low or high lift) Twin pump (low or high lift) - (Not available on sizes 00 and 0) Double pressure relief valve with diverter Compressor circuit breakers Fan speed regulation External tank with or without (500 and 000 l) 36

37 EWAD00-0E-SL ACCESSORIES Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM00J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) Cooling only Capacity class Cooling capacity Nom. kw Capacity control Method Stepless Minimum capacity % 5 Power input Cooling Nom. kw EER ESEER Dimensions Unit HeightxWidthxDepth mm,73x,9x,65,73x,9x3,065,73x,9x3,965,3x,36x3,070 Weight Unit kg,784,96,86 3,09 Operation weight kg,799,98,6 3,073 Water heat Type Plate to plate exchanger Water volume l Nominal water flow Cooling l/s Nominal water Cooling Heat kpa pressure drop exchanger Air heat exchanger Type High efficiency fin and tube type with integral subcooler Fan Air flow rate Nom. l/s 8,37 8,44,558,7 6,744 6,89 5,7 4,433 Speed rpm 75 Sound power level Cooling Nom. dba Sound pressure level Cooling Nom. dba Compressor Type Semi-hermetic single screw compressor Operation range Water side Cooling Min.~Max. CDB -5~5 Air side Cooling Min.~Max. CDB -8~48 Refrigerant Type R-34a Charge kg Circuits Quantity Piping connections Evaporator water inlet/outlet 3" Power supply Phase / Frequency / Voltage Hz / V 3~ / 50 /

38 EWAD-D-SS Air cooled chiller, standard efficiency, standard sound STRENGTHS Standard efficiency level Standard sound level configuration: condenser fan rotating at 90 rpm, rubber antivibration under compressor Stepless single-screw compressor Optimised for use with R-34a MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communication Large operation range (ambient temperature down to -8 C) Standard available Wye delta starter (y-d) Double set point Phase monitor Evaporator victaulic kit Evaporator water side design pressure 0 bar Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Ambient outside temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Fans circuit breakers Main switch interlock OPTIONS (factory mounted) Total heat recovery circuit Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit 0 mm evaporator insulation Fan silent mode Speedtrol Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump (low lift) One centrifugal pump (high lift) Two centrifugal pumps (low lift) Two centrifugal pumps (high lift) External tank without cabinet (500 l) External tank without cabinet (000 l) External tank (500 l) with cabinet External tank (000 l) with cabinet Double pressure relief valve with diverter Compressor circuit breakers Fan speed regulation s c r e w MicroTech III 38

39 ACCESSORIES Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM00J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) EWAD390D-SS Cooling only Capacity Class Cooling capacity Nom. kw Capacity control Method Stepless Minimum capacity %.5 Power input Cooling Nom. kw EER ESEER Dimensions Unit HeightxWidthxDepth mm,3x,34x3,39,3x,34x4,040 Weight Unit kg,960 4,030 4,0 4,30 4,35 Operation weight kg 3,090 4,95 4,395 Water heat Type Single pass shell & tube exchanger Water volume l Nominal water Cooling l/s flow Nominal water Cooling Heat kpa pressure drop exchanger Air heat exchanger Type High efficiency fin and tube type with integral subcooler Fan Air flow rate Nom. l/s 3,77 43,694 43,455 43,694 4,300 Speed rpm 90 Sound power level Cooling Nom. dba Sound pressure Cooling Nom. dba level Compressor Type Semi-hermetic single screw compressor Operation range Water side Cooling Min.~Max. CDB -5~5 Air side Cooling Min.~Max. CDB -8~48 Refrigerant Type R-34a Circuits Quantity Refrigerant circuit Charge kg Piping Evaporator water inlet/outlet connections 39.7mm Power supply Phase / Frequency / Voltage Hz / V 3 / 50 /

40 EWAD-D-SL Air cooled chiller, standard efficiency, low sound STRENGTHS Standard efficiency level Low sound level configuration: condenser fan rotating at 75/900 rpm, rubber antivibration under compressor, compressor sound enclosure Stepless single-screw compressor Optimised for use with R-34a MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communication Large operation range (ambient temperature down to -8 C) Standard available Wye delta starter (y-d) Double set point Phase monitor Evaporator victaulic kit Evaporator water side design pressure 0 bar Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Ambient outside temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Fans circuit breakers Main switch interlock OPTIONS (factory mounted) Total heat recovery circuit Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit 0 mm evaporator insulation Fan silent mode Speedtrol Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump (low lift) One centrifugal pump (high lift) Two centrifugal pumps (low lift) Two centrifugal pumps (high lift) External tank without cabinet (500 l) External tank without cabinet (000 l) External tank (500 l) with cabinet External tank (000 l) with cabinet Double pressure relief valve with diverter Compressor circuit breakers Fan speed regulation s c r e w MicroTech III 40

41 ACCESSORIES Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM00J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) EWAD D-SL Cooling only Capacity Class Cooling capacity Nom. kw Capacity control Method Stepless Minimum capacity %.5 Power input Cooling Nom. kw EER ESEER Dimensions Unit HeightxWidthxDepth mm,355x,34x,39,355x,34x3,39,3x,34x3,39,3x,34x4,040 Weight Unit kg,475,470,860,960 4,09 4,4 4,9 4,34 Operation weight kg,500,960 3,090 4,94 4,394 Water heat Type Plate to plate Single pass shell & tube exchanger Water volume l Nominal water Cooling l/s flow Nominal water Cooling Heat kpa pressure drop exchanger Air heat exchanger Type High efficiency fin and tube type with integral subcooler Fan Air flow rate Nom. l/s 5,300 4,900,900,600,300 4,48 33,489 3,57 Speed rpm Sound power level Cooling Nom. dba Sound pressure Cooling Nom. dba level Compressor Type Semi-hermetic single screw compressor Operation range Water side Cooling Min.~Max. CDB -5~5 Air side Cooling Min.~Max. CDB -8~48 Refrigerant Type R-34a Circuits Quantity Refrigerant circuit Charge kg Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage Hz/V 3 / 50 / 400 4

42 EWAD-D-SR Air cooled chiller, standard efficiency, reduced sound STRENGTHS Standard efficiency level Reduced sound level configuration: condenser fan rotating at 680/75 rpm, rubber antivibration under compressor, compressor sound enclosure under compressor, compressor sound enclosure. Stepless single-screw compressor Optimised for use with R-34a MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communication Large operation range (ambient temperature down to -8 C) Standard available Wye delta starter (y-d) Double set point Phase monitor Evaporator victaulic kit Evaporator water side design pressure 0 bar Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Ambient outside temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Fans circuit breakers Main switch interlock OPTIONS (factory mounted) Total heat recovery circuit Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit 0 mm evaporator insulation Fan silent mode Speedtrol Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump (low lift) One centrifugal pump (high lift) Two centrifugal pumps (low lift) Two centrifugal pumps (high lift) External tank without cabinet (500 l) External tank without cabinet (000 l) External tank (500 l) with cabinet External tank (000 l) with cabinet Double pressure relief valve with diverter Compressor circuit breakers Fan speed regulation s c r e w MicroTech III 4

43 ACCESSORIES Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM00J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) EWAD D-SR Cooling only Capacity Class Cooling capacity Nom. kw Capacity control Method Stepless Minimum capacity %.5 Power input Cooling Nom. kw EER ESEER Dimensions Unit HeightxWidthxDepth mm,355x,34x,39,355x,34x3,39,3x,34x3,39,3x,34x4,040 Weight Unit kg,60,890 3,0 4,040 4,40 Operation weight kg,650 3,00 3,40 4,34 4,54 Water heat Type Plate to plate Single pass shell & tube exchanger Water volume l Nominal water Cooling l/s flow Nominal water Cooling Heat kpa pressure drop exchanger Air heat exchanger Type High efficiency fin and tube type with integral subcooler Fan Air flow rate Nom. l/s 5,300 4,900,900,600,300 4,48 33,489 3,57 Speed rpm Sound power level Cooling Nom. dba Sound pressure Cooling Nom. dba level Compressor Type Semi-hermetic single screw compressor Operation range Water side Cooling Min.~Max. CDB -5~5 Air side Cooling Min.~Max. CDB -8~48 Refrigerant Type R-34a Charge kg Circuits Quantity Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage Hz / V 3 / 50 /

44 EWAD-D-SX Air cooled chiller, standard efficiency, extra low sound STRENGTHS Standard efficiency level Extra low sound level configuration: condenser fan rotating at 500 rpm, rubber antivibration under compressor, compressor and evaporator sound enclosure Stepless single-screw compressor Optimised for use with R-34a MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communication Large operation range (ambient temperature down to -8 C) Standard available Wye delta starter (y-d) Double set point Phase monitor Evaporator victaulic kit Evaporator water side design pressure 0 bar Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Ambient outside temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Fans circuit breakers Main switch interlock OPTIONS (factory mounted) Total heat recovery circuit Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit 0 mm evaporator insulation Fan silent mode Speedtrol Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump (low lift) One centrifugal pump (high lift) Two centrifugal pumps (low lift) Two centrifugal pumps (high lift) External tank without cabinet (500 l) External tank without cabinet (000 l) External tank (500 l) with cabinet External tank (000 l) with cabinet Double pressure relief valve with diverter Compressor circuit breakers Fan speed regulation s c r e w MicroTech III 44

45 ACCESSORIES Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM00J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) EWAD30-40D-SX Cooling only Capacity Class Cooling capacity Nom. kw Capacity control Method Stepless Minimum capacity %.5 Power input Cooling Nom. kw EER ESEER Dimensions Unit HeightxWidthxDepth mm,40x,34x3,39,40x,34x4,040,40x,34x4,940 Weight Unit kg 3,0 3,475 3,45 3,430 3,560 4,30 4,506 4,58 Operation weight kg 3,00 3,590 3,735 4,47 4,676 4,746 Water heat Type Single pass shell & tube exchanger Water volume l Nominal water Cooling l/s flow Nominal water Cooling Heat kpa pressure drop exchanger Air heat exchanger Type High efficiency fin and tube type with integral subcooler Fan Air flow rate Nom. l/s,900 7,900 7,00 6,495 5,933 8,65 33,6 Speed rpm 500 Sound power level Cooling Nom. dba Sound pressure Cooling Nom. dba level Compressor Type Semi-hermetic single screw compressor Operation range Water side Cooling Min.~Max. CDB -5~5 Air side Cooling Min.~Max. CDB -8~48 Refrigerant Type R-34a Circuits Quantity Refrigerant circuit Charge kg Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage Hz / V 3 / 50 /

46 EWAD-D-XS Air cooled chiller, high efficiency, standard sound STRENGTHS High efficiency Standard sound level configuration: condenser fan rotating at 900/90 rpm, rubber antivibration under compressor Stepless single-screw compressor Optimised for use with R-34a MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communication Large operation range (ambient temperature down to -8 C) Standard available Wye delta starter (y-d) Double set point Phase monitor Evaporator victaulic kit Evaporator water side design pressure 0 bar Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Ambient outside temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Fans circuit breakers Main switch interlock OPTIONS (factory mounted) Total heat recovery circuit Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit 0 mm evaporator insulation Fan silent mode Speedtrol Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump (low lift) One centrifugal pump (high lift) Two centrifugal pumps (low lift) Two centrifugal pumps (high lift) External tank without cabinet (500 l) External tank without cabinet (000 l) External tank (500 l) with cabinet External tank (000 l) with cabinet Double pressure relief valve with diverter Compressor circuit breakers Fan speed regulation s c r e w MicroTech III 46

47 ACCESSORIES Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM00J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) EWAD50D-XS Cooling only Capacity Class Cooling capacity Nom. kw Capacity control Method Stepless Minimum capacity %.5 Power input Cooling Nom. kw EER ESEER Dimensions Unit HeightxWidthxDepth mm,355x,34x3,38,355x,34x4,040,3x,34x4,040,3x,34x4,940 Weight Unit kg,905 3,85 3,35 3,40 3,50 4,670 4,685 Operation weight kg 3,000 3,400 3,780 4,940 Water heat Type Single pass shell & tube exchanger Water volume l Nominal water Cooling l/s flow Nominal water Cooling Heat kpa pressure drop exchanger Air heat exchanger Type High efficiency fin and tube type with integral subcooler Fan Air flow rate Nom. l/s,300 30,600 9,700 44,000 43,000 43,695 54,66 Speed rpm Sound power level Cooling Nom. dba Sound pressure Cooling Nom. dba level Compressor Type Semi-hermetic single screw compressor Operation range Water side Cooling Min.~Max. CDB -5~5 Air side Cooling Min.~Max. CDB -8~48 Refrigerant Type R-34a Circuits Quantity Refrigerant circuit Charge kg Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage Hz / V 3 / 50 /

48 EWAD-D-XR Air cooled chiller, high efficiency, reduced sound STRENGTHS High efficiency Reduced sound level configuration: condenser fan rotating at 680/75 rpm, rubber antivibration under compressor, compressor sound enclosure Stepless single-screw compressor Optimised for use with R-34a MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communication Large operation range (ambient temperature down to -8 C) Standard available Wye delta starter (y-d) Double set point Phase monitor Evaporator victaulic kit Evaporator water side design pressure 0 bar Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Ambient outside temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Fans circuit breakers Main switch interlock OPTIONS (factory mounted) Total heat recovery circuit Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit 0 mm evaporator insulation Fan silent mode Speedtrol Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump (low lift) One centrifugal pump (high lift) Two centrifugal pumps (low lift) Two centrifugal pumps (high lift) External tank without cabinet (500 l) External tank without cabinet (000 l) External tank (500 l) with cabinet External tank (000 l) with cabinet Double pressure relief valve with diverter Compressor circuit breakers Fan speed regulation s c r e w MicroTech III 48

49 ACCESSORIES Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM00J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) EWAD70-390D-XR Cooling only Capacity Class Cooling capacity Nom. kw Capacity control Method Stepless Minimum capacity %.5 Power input Cooling Nom. kw EER ESEER Dimensions Unit HeightxWidthxDepth mm,355x,34x3,38,355x,34x4,040,3x,34x4,040,3x,34x4,940 Weight Unit kg 3,005 3,385 3,335 3,340 3,60 4,770 4,785 Operation weight kg 3,00 3,500 3,880 5,040 Water heat Type Single pass shell & tube exchanger Water volume l Nominal water Cooling l/s flow Nominal water Cooling Heat kpa pressure drop exchanger Air heat exchanger Type High efficiency fin and tube type with integral subcooler Fan Air flow rate Nom. l/s,500 33,488 4,86 4,864 Speed rpm Sound power level Cooling Nom. dba Sound pressure Cooling Nom. dba level Compressor Type Semi-hermetic single screw compressor Operation range Water side Cooling Min.~Max. CDB -5~5 Air side Cooling Min.~Max. CDB -8~48 Refrigerant Type R-34a Circuits Quantity Refrigerant circuit Charge kg Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage Hz/V 3 / 50 /

50 EWAD-D-HS Air cooled chiller, high ambient STRENGTHS High ambient Standard sound level configuration: condenser fan rotating at 900/90 rpm, rubber antivibration under compressor Stepless single-screw compressor Optimised for use with R-34a MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications Large operation range (ambient temperature down to -8 C) Standard available Wye delta starter (y-d) Double set point Phase monitor Evaporator victaulic kit Evaporator water side design pressure 0 bar Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Ambient outside temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Fans circuit breakers Main switch interlock OPTIONS (factory mounted) Total heat recovery circuit Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit 0 mm evaporator insulation Fan silent mode Speedtrol Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump (low lift) One centrifugal pump (high lift) Two centrifugal pumps (low lift) Two centrifugal pumps (high lift) External tank without cabinet (500 l) External tank without cabinet (000 l) External tank (500 l) with cabinet External tank (000 l) with cabinet Double pressure relief valve with diverter Compressor circuit breakers Fan speed regulation s c r e w MicroTech III 50

51 ACCESSORIES Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM00J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) EWAD D-HS Cooling only Capacity Class Cooling capacity Nom. kw Capacity control Method Stepless Minimum capacity %.5 Power input Cooling Nom. kw EER ESEER Dimensions Unit HeightxWidthxDepth mm,3x,34x,39,3x,34x3,339,3x,34x4,040,3x,34x4,940 Weight Unit kg,475,470,865,870 3,85 3,77 3,94 4,356 4,36 4,366 Operation weight kg,500,960 3,300 3,447 4, 4,56 Water heat Type Plate to plate Single pass shell & tube exchanger Water volume l Nominal water Cooling l/s flow Nominal water Cooling Heat kpa pressure drop exchanger Air heat exchanger Type High efficiency fin and tube type with integral subcooler Fan Air flow rate Nom. l/s 3,900,800 35,900 35,000 34,00 47,900 43,694 4,300 54,66 Fan motor Speed Cooling Nom. rpm Sound power level Cooling Nom. dba Sound pressure Cooling Nom. dba level Compressor Type Semi-hermetic single screw compressor Operation range Water side Cooling Min.~Max. CDB -5~5 Air side Cooling Min.~Max. CDB -8~48 Refrigerant Type R-34a Circuits Quantity Refrigerant circuit Charge kg Piping Evaporator water inlet/outlet connections Power supply Phase / Frequency / Voltage Hz / V 3 / 50 / 400 5

52 EWAD-BZSS/SL Air cooled inverter chiller, standard efficiency, standard/low sound STRENGHTS ESEER up to 4.70 All models are PED pressure vessel approved Inverter stepless single-screw compressor Optimised for use with R-34a Cooling range: 39-55kW truly independent refrigerant circuits DX shell and tube evaporator one pass refrigerant side to minimize pressure drops The ability to vary the output power in direct relation to the cooling requirements of the system allows to achieve building comfort conditions much faster at start-up Standard electronic expansion valve Partial and total heat recovery option available Power factor over 0.95 Standard operation range down to -0 C STANDARD AVAILABLE Double setpoint Fans circuit breakers with thermal overload relays Phase monitor Inverter compressor starter Evaporator victaulic kit Fan silent mode Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Low pressure side manometers Hour run meter General fault contactor Main switch interlock Fan speed regulation OPTIONS Total heat recovery ( circuit) Partial heat recovery Brine version Under/overvoltage control Energy meter Current limit / display 0mm evaporator insulation Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch High pressure side manometers Container kit Rubber anti-vibration mount Spring anti-vibration mount One centrifugal pump (low or high lifting) Two centrifugal pumps (low or high lifting) External tank with or without cabinet (500 or 000l) Set point reset, demand limit and alarm Double pressure relief valve with diverter Accessories Address card RS485 (EKAC00J) Ethernet card BACnet (EKACBAC) Communication card LON (EKACLON) Converter RS485 to RS3 (EKCON) Converter RS485 to USB (EKCONUSB) Fixed modem (EKMODEM) GSM modem (EKGSMOD) Remote user interface (EKRUPCJ) Plant Visor (EKPVJ) PCO s c r e w 5

53 EWAD330,360BZ Cooling only Capacity class Cooling capacity Nom. kw Capacity control Method Stepless Minimum capacity % 3.5 Power input Cooling Nom. kw EER ESEER Dimensions Unit HeightxWidthxDepth mm,355x,34x4,38,355x,34x5,8,355x,34x6,8 Weight (SS) Unit kg 4,90 4,590 4,990 Operation weight kg 4,440 4,840 5,40 Weight (SL) Unit kg 4,340 4,740 5,40 Operation weight kg 4,590 4,990 5,390 Water heat Type Single pass shell & tube exchanger Water volume l Nominal water flow Cooling l/s Nominal water Cooling Heat kpa pressure drop exchanger Air heat exchanger Type High efficiency fin and tube type with integral subcooler Fan Air flow rate Nom. l/s 3,667 40,833 49,000 Speed rpm 700 Sound power level (SS) Cooling Nom. dba Sound power level (SL) Cooling Nom. dba Sound pressure level (SS) Cooling Nom. dba Sound pressure level (SL) Cooling Nom. dba Compressor Type Semi-hermetic single screw compressor Operation range Water side Cooling Min.~Max. CDB -9.5~5 Air side Cooling Min.~Max. CDB -0~45 Refrigerant Type R-34a Charge kg Circuits Quantity Piping connections Evaporator water inlet/outlet 68.3mm Power supply Phase / Frequency / Voltage Hz / V 3~ / 50 /

54 EWAD-BZXS/XL/XR Air cooled inverter chiller, high efficiency, standard/low/reduced sound STRENGHTS High seasonal efficiency (ESEER up to 5.0) All models are PED pressure vessel approved Inverter stepless single-screw compressor Optimised for use with R-34a Cooling range: 39-55kW truly independent refrigerant circuits DX shell and tube evaporator one pass refrigerant side to minimize pressure drops The ability to vary the output power in direct relation to the cooling requirements of the system allows to achieve building comfort conditions much faster at start-up Standard electronic expansion valve Partial and total heat recovery option available Power factor over 0.95 Standard operation range down to -0 C STANDARD AVAILABLE Double setpoint Fans circuit breakers Phase monitor Inverter compressor starter Evaporator victaulic kit Fan silent mode Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Low pressure side manometers Hour run meter General fault contactor Main switch interlock Fan speed regulation OPTIONS Total heat recovery ( circuit) Partial heat recovery Brine version Under/overvoltage control Energy meter Current limit - display 0mm evaporator insulation Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch High pressure side manometers Container kit Rubber anti-vibration mount Spring anti-vibration mount One centrifugal pump (low or high lifting) Two centrifugal pumps (low or high lifting) External tank with or without cabinet (500 or 000l) Set point reset, demand limit and alarm Double pressure relief valve with diverter Accessories Address card RS485 (EKAC00J) Ethernet card BACnet (EKACBAC) Communication card LON (EKACLON) Converter RS485 to RS3 (EKCON) Converter RS485 to USB (EKCONUSB) Fixed modem (EKMODEM) GSM modem (EKGSMOD) Remote user interface (EKRUPCJ) Plant Visor (EKPVJ) PCO s c r e w 54

55 EWAD330,360BZ Cooling only Capacity class Cooling capacity Nom. kw Capacity control Method Stepless Minimum capacity % 3 Power input Cooling Nom. kw EER ESEER Dimensions Unit HeightxWidthxDepth mm,355x,34x4,38,355x,34x5,8,355x,34x6,8 Weight (XS) Unit kg 4,90 4,590 4,990 Operation weight kg 4,440 4,840 5,40 Weight (XL) Unit kg 4,340 4,740 5,40 Operation weight kg 4,590 4,990 5,390 Weight (XR) Unit kg 4,390 4,790 5,90 Operation weight kg 4,640 5,040 5,440 Water heat Type Single pass shell & tube exchanger Water volume l Nominal water flow Cooling l/s Nominal water Cooling Heat kpa pressure drop exchanger Air heat exchanger Type High efficiency fin and tube type with integral subcooler Fan Air flow rate Nom. l/s 3,667 40,833 49,000 Speed rpm 700 Sound power level (XS) Cooling Nom. dba Sound pressure Cooling Nom. dba level (XS) Sound power level (XL) Cooling Nom. dba Sound pressure Cooling Nom. dba level (XL) Sound power level (XR) Cooling Nom. dba Sound pressure Cooling Nom. dba level (XR) Compressor Type Semi-hermetic single screw compressor Operation range Water side Cooling Min.~Max. CDB -9.5~5 Air side Cooling Min.~Max. CDB -0~45 Refrigerant Type R-34a Charge kg Circuits Quantity Piping connections Evaporator water inlet/outlet 68.3 Power supply Phase / Frequency / Voltage Hz / V 3~ / 50 /

56 ewyd-bzss Air cooled heat pump inverter chiller, standard efficiency, standard sound STRENGTHS Optimised for use with R-34a Cooling range: kW Heating range: 70-65kW EER range up to.83 Standard electronic expansion valve DX shell and tube evaporator one pass refrigerant side to minimize pressure drops Low starting current No gas boiler required Optimised defrost cycles Optimum ESEER values Partial and total heat recovery option available PID microprocessor control Power factor up to truly independent refrigerant circuits Standard operation range down to - C STANDARD AVAILABLE Double set point Fans thermal relays Phase monitor Inverter compressor starter Evaporator victaulic kit Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Low pressure side manometers General fault contactor Hour run meter OPTIONS Partial heat recovery Brine version Under/ overvoltage control Current limit - display 0 mm evaporator insulation Fan speed control device (phase cut on fan) Condenser coil guards Cu-cu condensing coils Cu-Cu-Sn condensing coils Alucoat condensing coils Evaporator flow switch High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump (low lift) One centrifugal pump (high lift) Two centrifugal pumps (low lift) Two centrifugal pumps (high lift) Double pressure relief valve with diverter External tank with or without cabinet (500 or 000 l) Fan silent mode Accessories Address card RS485 (EKAC00J) Ethernet card BACnet (EKACBAC) Communication card LON (EKACLON) Converter RS485 to RS3 (EKCON) Converter RS485 to USB (EKCONUSB) Fixed modem (EKMODEM) GSM modem (EKGSMOD) Remote user interface (EKRUPCJ) Plant Visor (EKPVJ) s c r e w PCO 56

57 EWYD50-90BZ Heating & Cooling Capacity class Cooling capacity Nom. kw Heating capacity Nom. kw Capacity control Method Stepless Minimum capacity % 3 9 Power input Cooling Nom. kw Heating Nom. kw EER COP ESEER Dimensions Unit HeightxWidthxDepth mm,335x,54x3,547,335x,54x4,38,335x,54x5,8,335x,54x6,583 Weight Unit kg 3,40 3,455 3,500 3,870 3,940 4,00 4,390 5,05 5,495 5,735 Operation weight kg 3,550 3,595 3,640 4,00 4,068 4,38 4,58 5,55 5,74 5,964 5,953 Water heat Type Single pass shell & tube exchanger Water volume l Nominal water Cooling l/s flow Heating l/s Nominal water Cooling Heat kpa pressure drop exchanger Heating Heat kpa exchanger Air heat exchanger Type High efficiency fin and tube type with integral subcooler Fan Air flow rate Nom. l/s 3,78 4,304 5,880 63,456 Speed rpm 90 Sound power level Cooling Nom. dba Heating Nom. dba Sound pressure level Cooling Nom. dba Heating Nom. dba Compressor Type Semi-hermetic single screw compressor Operation range Water side Cooling Min.~Max. CDB -8~5 Air side Cooling Min.~Max. CDB -0~45 Refrigerant Type R-34a Charge kg Circuits Quantity 3 Piping connections Evaporator water inlet/outlet mm Power supply Phase / Frequency / Voltage Hz / V 3~ / 50 /

58 Ewyd-Bzsl Air cooled heat pump inverter chiller standard efficiency, low sound STRENGTHS Optimised for use with R-34a Cooling range: kW Heating range: 70-65kW EER range up to.87 Standard electronic expansion valve DX shell and tube evaporator one pass refrigerant side to minimize pressure drops Low operating sound level Low starting current No gas boiler required Optimised defrost cycles Optimum ESEER values Partial and total heat recovery option available PID microprocessor control Power factor up to truly independent refrigerant circuits Standard operation range down to - C STANDARD AVAILABLE Double set point Fans thermal relays Phase monitor Inverter compressor starter Evaporator victaulic kit Fan speed control device (phase cut on fan) Evaporator electric heater Electronic expansion device Discharge line shut off valve Suction line shut off valve Low pressure side manometers General fault contactor Main switch interlock Hour run meter OPTIONS Partial heat recovery Brine version Under/ overvoltage control Current limit - display 0 mm evaporator insulation Condenser coil guards Cu-cu condensing coils Cu-Cu-Sn condensing coils Alucoat fins Evaporator flow switch High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump (low lift) One centrifugal pump (high lift) Two centrifugal pumps (low lift) Two centrifugal pumps (high lift) Double pressure relief valve with diverter External tank with or without cabinet (500 or 000 l) Accessories Address card RS485 (EKAC00J) Ethernet card BACnet (EKACBAC) Communication card LON (EKACLON) Converter RS485 to RS3 (EKCON) Converter RS485 to USB (EKCONUSB) Fixed modem (EKMODEM) GSM modem (EKGSMOD) Remote user interface (EKRUPCJ) Plant Visor (EKPVJ) s c r e w PCO 58

59 EWYD50-90BZ Heating & Cooling Capacity class Cooling capacity Nom. kw Heating capacity Nom. kw Capacity control Method Stepless Minimum capacity % 3 9 Power input Cooling Nom. kw Heating Nom. kw EER COP ESEER Dimensions Unit HeightxWidthxDepth mm,335x,54x3,547,335x,54x4,38,335x,54x5,8,335x,54x6,583 Weight Unit kg 3,750 3,795 3,840 4,0 4,80 4,350 4,730 5,55 6,005 6,45 Operation weight kg 3,888 3,933 3,978 4,343 4,408 4,478 4,858 5,765 6,34 6,474 6,463 Water heat Type Single pass shell & tube exchanger Water volume l Nominal water Cooling l/s flow Heating l/s Nominal water Cooling Heat kpa pressure drop exchanger Heating Heat kpa exchanger Air heat exchanger Type High efficiency fin and tube type with integral subcooler Fan Air flow rate Cooling Nom. l/s 4,43 3,576 40,70 48,864 Heating Nom. l/s 3,78 4,304 5,880 63,456 Fan motor Speed Cooling Nom. rpm 75 Heating Nom. rpm 90 Sound power level Cooling Nom. dba Heating Nom. dba Sound pressure level Cooling Nom. dba Heating Nom. dba Compressor Type Semi-hermetic single screw compressor Operation range Water side Cooling Min.~Max. CDB -8~5 Air side Cooling Min.~Max. CDB -0~45 Refrigerant Type R-34a Charge kg Circuits Quantity 3 Piping connections Evaporator water inlet/outlet mm Power supply Phase / Frequency / Voltage Hz / V 3 ~/ 50 /

60 EWAD-C-SS/SL Air cooled chiller, standard efficiency, standard/low sound STRENGHTS Wide capacity range: 6 sizes to cover a range from 647 to,9 kw Stepless single-screw compressor Large operation range (ambient temperature down to -8 C and up to 46 C) All models are PED pressure vessel approved Optimised for use with R-34a -3 truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator one pass refrigerant side to minimize pressure drops Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications STANDARD AVAILABLE Wye-delta starter (y-d) Double setpoint Fans thermal relays Phase monitor Evaporator victaulic kit 0mm evaporator insulation Evaporator electric heater Electronic expansion device Discharge line shut off valve Ambient temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm Fan circuit breakers Main switch interlock Emergency stop OPTIONS Total heat recovery Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Ampere volt meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit Speedtrol (fan speed control device) Condenser coil guards Evaporator area guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch Suction line shut off valve High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump Two centrifugal pumps Compressor circuit breakers Double pressure relief valve with diverter Fans speed regulation Refrigerant recovery tank Evaporator right water connection Ground fault relay s c r e w MicroTech III 60

61 EWAD-C- ACCESSORIES Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM00J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) Cooling only Capacity class C C C3 H4 C4 C5 C6 C7 C8 C9 C0 Cooling capacity Nom. kw ,064,5,39,48,49,538,6,74,80,875,9 Capacity control Method Stepless Minimum capacity %.5 7 Power input Cooling Nom. kw EER ESEER Dimensions Unit HeightxWidthxDepth mm,540x,85,540x,85,540x,85x6,85,540x,85x8,885 x7,085 x7,985,540x,85x0,85,540x,85x,085,540x,85x,985 Weight (SS) Unit kg 5,630 5,740 5,760 6,80 6,560 7,00 7,80 7,900 0,30 0,30 0,70 0,770,40,600 Operation weight kg 5,90 5,990 6,00 6,530 6,80 7,50 7,50 8,80 0,730,0,60,0,480 Weight (SL) Unit kg 5,90 6,030 6,050 6,570 6,850 7,300 7,570 8,90 0,750 0,770,50,0,680,040 Operation weight kg 6,00 6,80 6,300 6,80 7,00 7,540 7,80 8,570,70,550,700,560,90 Water heat Type Single pass shell & tube exchanger Water volume l Nominal water Cooling l/s flow Nominal water Cooling Heat kpa pressure drop exchanger Air heat exchanger Type High efficiency fin and tube type with integral subcooler Fan Air flow rate Nom. l/s 53,444 64,33 74,8 85,50 96,99 06,888 7,577 8,66 Speed rpm 90 Sound power Cooling Nom. dba level (SS) Sound pressure Cooling Nom. dba level (SS) Sound power Cooling Nom. dba level (SL) Sound pressure Cooling Nom. dba level (SL) Compressor Type Semi-hermetic single screw compressor Operation range Water side Cooling Min.~Max. CDB -8 ~ 5 Air side Cooling Min.~Max. CDB -8 ~ 46 Refrigerant Type R-34a Charge kg Circuits Quantity 3 Piping Evaporator water inlet/outlet connections 68.3mm 9.mm 73mm Power supply Phase / Frequency / Voltage Hz / V 3 / 50 / 400 6

62 EWad-c-sR Air cooled chiller, standard efficiency, reduced sound STRENGHTS Reduced sound version Wide capacity range: 6 sizes to cover a range from 69 to,833 kw Stepless single-screw compressor Large operation range (ambient temperature down to -8 C and up to 46 C) All models are PED pressure vessel approved Optimised for use with R-34a -3 truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator one pass refrigerant side to minimize pressure drops Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications STANDARD AVAILABLE Wye-delta starter (y-d) Double setpoint Fans thermal relays Phase monitor Evaporator victaulic kit 0mm evaporator insulation Evaporator electric heater Electronic expansion device Discharge line shut off valve Ambient temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm Double pressure relief valve with diverter Fan circuit breakers Main switch interlock Emergency stop OPTIONS Total heat recovery Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Ampere volt meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit Speedtrol (fan speed control device) Condenser coil guards Evaporator area guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch Suction line shut off valve High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump Two centrifugal pumps Compressor circuit breakers Double pressure relief valve with diverter Fans speed regulation Refrigerant recovery tank Evaporator right water connection Ground fault relay s c r e w MicroTech III 6

63 ACCESSORIES Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM00J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) EWAD-C- Cooling only Capacity class C0 C C H4 C3 C4 C5 C4 C7 C8 C9 Cooling capacity Nom. kw ,00,,70,3,367,47,556,63,74,795,833 Capacity control Method Stepless Minimum capacity %.5 7 Power input Cooling Nom. kw EER ESEER Dimensions Unit HeightxWidthxDepth mm,540x,85,540x,85,540x,85x6,85,540x,85x8,885 x7,085 x7,985,540x,85x0,85,540x,85x,085,540x,85x,985 Weight Unit kg 5,90 6,030 6,050 6,750 6,850 7,300 7,570 8,90 0,750 0,770,50,0,680,040 Operation weight kg 6,00 6,80 6,300 6,80 7,00 7,540 7,80 8,570,70,550,700,560,90 Water heat Type Single pass shell & tube exchanger Water volume l Nominal water Cooling l/s flow Nominal water Cooling Heat kpa pressure drop exchanger Air heat exchanger Type High efficiency fin and tube type with integral subcooler Fan Air flow rate Nom. l/s 4,006 49,07 57,408 65,60 73,8 8,0 90,3 90,6 98,47 Speed rpm 75 Sound power level Cooling Nom. dba Sound pressure Cooling Nom. dba level Compressor Type Semi-hermetic single screw compressor Operation range Water side Cooling Min.~Max. CDB -8 ~ 5 Air side Cooling Min.~Max. CDB -8 ~ 46 Refrigerant Type R-34a Charge kg Circuits Quantity 3 Piping Evaporator water inlet/outlet connections 68.3mm 9.mm 73mm Power supply Phase / Frequency / Voltage Hz / V 3 / 50 /

64 EWAD-C-XS/XL Air cooled chiller, high efficiency, standard/low sound STRENGHTS High efficiency version Wide capacity range: 9 sizes to cover a range from 756 to,008 kw Stepless single-screw compressor Large operation range (ambient temperature down to -8 C and up to 50 C) All models are PED pressure vessel approved Optimised for use with R-34a -3 truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator one pass refrigerant side to minimize pressure drops Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications STANDARD AVAILABLE Wye-delta starter (y-d) Double setpoint Fans thermal relays Phase monitor Evaporator victaulic kit 0mm evaporator insulation Evaporator electric heater Electronic expansion device Discharge line shut off valve Ambient temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm Fan circuit breakers Main switch interlock Emergency stop OPTIONS Total heat recovery Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Ampere volt meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit Speedtrol (fan speed control device) Condenser coil guards Evaporator area guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch Suction line shut off valve High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump Two centrifugal pumps Compressor circuit breakers Double pressure relief valve with diverter Fans speed regulation Refrigerant recovery tank Evaporator right water connection Ground fault relay s c r e w MicroTech III 64

65 EWAD-C- ACCESSORIES Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM00J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) Cooling only Capacity class C0 C C C3 H4 H5 C4 C5 C6 C7 C8 C9 C0 C C Cooling capacity Nom. kw ,00,074,96,80,349,45,55,409,56,596,685,768,858,90,953,008 Capacity control Method Stepless Minimum capacity %.5 7 Power input Cooling Nom. kw EER ESEER Dimensions Unit HeightxWidthxDepth mm,540x,85,540x,85,540x,85,540x,85x9,785,540x,85x,985,540x,85,540x,85 x6,85 x7,085 x7,985 x,885 x3,785,540x,85x4,685 Weight (XS) Unit kg 5,990 6,340 6,360 7,90 7,470 8,0 8,40 8,900 0,560,30,570,900,60,600 Operation weight kg 6,40 6,580 6,600 7,600 7,870 8,60 8,630 9,890,040,70,430,760 3,40 3,470 Weight (XL) Unit kg 6,80 6,630 6,650 7,480 7,760 8,50 8,530 9,90,000,760,00,350,700 3,040 Operation weight kg 6,50 6,870 6,890 7,880 8,60 8,900 8,90 0,80,490,60,870 3,00 3,580 3,90 Water heat Type Single pass shell & tube exchanger Water volume l Nominal water flow Cooling l/s Nominal water Cooling Heat kpa pressure drop exchanger Air heat exchanger Type High efficiency fin and tube type with integral subcooler Fan Air flow rate Nom. l/s 64,33 74,8 85,50 06,888 8,66 38,954 49,643 60,33 Speed rpm Fan motor Speed Cooling Nom. rpm Sound power level (XL) Cooling Nom. dba Sound pressure Cooling Nom. dba level (XL) Sound power level (XL) Cooling Nom. dba Sound pressure Cooling Nom. dba level (XL) Compressor Type Semi-hermetic single screw compressor Operation range Water side Cooling Min.~Max. CDB -8 ~ 5 Air side Cooling Min.~Max. CDB -8 ~ 50 Refrigerant Type R-34a Charge kg Circuits Quantity 3 Refrigerant circuit Charge kg Piping connections Evaporator water inlet/outlet mm Power supply Phase / Frequency / Voltage Hz / V 3~ / 50 / / 50 / 400 3~ / 50 / / 50 /

66 EWad-c-xR Air cooled chiller, high efficiency, reduced sound STRENGHTS High efficiency and reduced sound version Wide capacity range: 9 sizes to cover a range from 736 to,959 kw Stepless single-screw compressor Large operation range (ambient temperature down to -8 C and up to 50 C) All models are PED pressure vessel approved Optimised for use with R-34a -3 truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator one pass refrigerant side to minimize pressure drops Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications STANDARD AVAILABLE Wye-delta starter (y-d) Double setpoint Fans thermal relays Phase monitor Evaporator victaulic kit 0mm evaporator insulation Evaporator electric heater Electronic expansion device Discharge line shut off valve Ambient temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm Fan circuit breakers Main switch interlock Emergency stop OPTIONS Total heat recovery Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Ampere volt meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit Speedtrol (fan speed control device) Condenser coil guards Evaporator area guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch Suction line shut off valve High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump Two centrifugal pumps Compressor circuit breakers Double pressure relief valve with diverter Fans speed regulation Refrigerant recovery tank Evaporator right water connection Ground fault relay s c r e w MicroTech III 66

67 ACCESSORIES Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM00J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) EWAD-C- Cooling only Capacity class C0 C C C3 H4 H5 C4 C5 C6 C7 C8 C9 C0 C C Cooling capacity Nom. kw ,04,68,47,30,367,468,378,486,550,639,7,83,854,90,959 Capacity control Method Stepless Minimum capacity %.5 7 Power input Cooling Nom. kw EER ESEER Dimensions Unit HeightxWidthxDepth mm,540x,85,540x,85,540x,85,540x,85x9,785,540x,85x,985,540x,85,540x,85 x6,85 x7,085 x7,985 x,885 x3,785,540x,85x4,685 Weight Unit kg 6,80 6,630 6,650 7,480 7,760 8,50 8,530 9,90,000,760,00,350,700 3,040 Operation weight kg 6,50 6,870 6,890 7,880 8,60 8,900 8,90 0,80,490,60,870 3,00 3,580 3,90 Water heat Type Single pass shell & tube exchanger Water volume l Nominal water flow Cooling l/s Nominal water Cooling Heat kpa pressure drop exchanger Air heat exchanger Type High efficiency fin and tube type with integral subcooler Fan Air flow rate Nom. l/s 49,07 57,408 65,60 8,0 8,04 98,44 06,66 4,87 3,08 3,0 Speed rpm 75 Sound power level Cooling Nom. dba Sound pressure level Cooling Nom. dba Compressor Type Semi-hermetic single screw compressor Operation range Water side Cooling Min.~Max. CDB -8 ~ 5 Air side Cooling Min.~Max. CDB -8 ~ 50 Refrigerant Type R-34a Charge kg Circuits Quantity 3 Refrigerant circuit Charge kg Piping connections Evaporator water inlet/outlet mm Power supply Phase / Frequency / Voltage Hz / V 3 / 50 /

68 EWAD-C-PS/PL Air cooled chiller, premium efficiency, standard/low sound STRENGHTS Premium efficiency version Wide capacity range: 9 sizes to cover a range from 8 to,56 kw Stepless single-screw compressor Large operation range (ambient temperature down to -8 C and up to 5 C) All models are PED pressure vessel approved Optimised for use with R-34a truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator one pass refrigerant side to minimize pressure drops Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications STANDARD AVAILABLE Wye-delta starter (y-d) Double setpoint Fans thermal relays Phase monitor Evaporator victaulic kit 0mm evaporator insulation Evaporator electric heater Electronic expansion device Discharge line shut off valve Ambient temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm Fan circuit breakers Main switch interlock Emergency stop OPTIONS Total heat recovery Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Ampere volt meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit Speedtrol (fan speed control device) Condenser coil guards Evaporator area guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch Suction line shut off valve High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump Two centrifugal pumps Compressor circuit breakers Fans speed regulation Double pressure relief valve with diverter Refrigerant recovery tank Evaporator right water connection Ground fault relay s c r e w MicroTech III 68

69 ACCESSORIES Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM00J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) EWAD-C- Cooling only Capacity class C C C3 C4 C5 C6 Cooling capacity Nom. kw ,074,58,79,390,474,56 Capacity control Method Stepless Minimum capacity %.5 Power input Cooling Nom. kw EER ESEER Dimensions Unit HeightxWidthxDepth mm,540x,85,540x,85x8,885,540x,85x9,785 x,085,540x,85x,985 Weight (PS) Unit kg 7,530 7,660 8,90 8,550 9,390 9,730 Operation weight kg 8,30 8,700 9,330 9,590 0,380 0,70 Weight (PL) Unit kg 7,80 7,950 8,580 8,840 0,380 0,70 Operation weight kg 8,40 8,990 9,60 9,880 0,670,00 Water heat Type Single pass shell & tube exchanger Water volume l 599,043, Nominal water flow Cooling l/s Nominal water Cooling Heat kpa pressure drop exchanger Air heat exchanger Type High efficiency fin and tube type with integral subcooler Fan Air flow rate Nom. l/s 96,99 06,888 7,577 8,66 8,66 Speed rpm 90 Sound power level (PS) Cooling Nom. dba Sound pressure Cooling Nom. dba level (PS) Sound power level (PL) Cooling Nom. dba Sound pressure Cooling Nom. dba level (PL) Compressor Type Semi-hermetic single screw compressor Operation range Water side Cooling Min.~Max. CDB -8 ~ 5 Air side Cooling Min.~Max. CDB -8 ~ 5 Refrigerant Type R-34a Charge kg Circuits Quantity Piping connections Evaporator water inlet/outlet mm Power supply Phase / Frequency / Voltage Hz / V 3 / 50 /

70 EWad-c-pR Air cooled chiller, premium efficiency, reduced sound STRENGHTS Premium efficiency and reduced sound version Wide capacity range: 9 sizes to cover a range from 809 to,5 kw Stepless single-screw compressor Large operation range (ambient temperature down to -8 C and up to 5 C) All models are PED pressure vessel approved Optimised for use with R-34a truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator one pass refrigerant side to minimize pressure drops Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications STANDARD AVAILABLE Wye-delta starter (y-d) Double setpoint Fans thermal relays Phase monitor Evaporator victaulic kit 0mm evaporator insulation Evaporator electric heater Electronic expansion device Discharge line shut off valve Ambient temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm Fan circuit breakers Main switch interlock Emergency stop OPTIONS Total heat recovery Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Ampere volt meter Capacitors cosfi 0.9 Current limit - display Evaporator flange kit Speedtrol (fan speed control device) Condenser coil guards Evaporator area guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch Suction line shut off valve High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump Two centrifugal pumps Compressor circuit breakers Double pressure relief valve with diverter Fans speed regulation Refrigerant recovery tank Evaporator right water connection Ground fault relay s c r e w MicroTech III 70

71 ACCESSORIES Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM00J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) EWAD-C- Cooling only Capacity class C0 C C3 C4 C5 C6 Cooling capacity Nom. kw ,053,3,5,359,439,5 Capacity control Method Stepless Minimum capacity %.5 Power input Cooling Nom. kw EER ESEER Dimensions Unit HeightxWidthxDepth mm,540x,85,540x,85x8,885,540x,85x9,785 x,085,540x,85x,985 Weight Unit kg 7,80 7,950 8,580 8,840 0,380 0,70 Operation weight kg 8,40 8,990 9,60 9,880 0,670,00 Water heat Type Single pass shell & tube exchanger Water volume l 599,043, Nominal water flow Cooling l/s Nominal water Cooling Heat kpa pressure drop exchanger Air heat exchanger Type High efficiency fin and tube type with integral subcooler Fan Air flow rate Nom. l/s 73,8 8,0 90,3 98,44 98,47 Speed rpm 75 Sound power level Cooling Nom. dba Sound pressure level Cooling Nom. dba Compressor Type Semi-hermetic single screw compressor Operation range Water side Cooling Min.~Max. CDB -8 ~ 5 Air side Cooling Min.~Max. CDB -8 ~ 5 Refrigerant Type R-34a Charge kg Circuits Quantity Piping Evaporator water inlet/outlet mm connections Power supply Phase / Frequency / Voltage Hz / V 3 / 50 / 400 7

72 EWad-cZXS/XL Air cooled inverter chiller, high efficiency, standard/low sound STRENGTHS Wide capacity range Lower starting current and optimum power factor Wide range of operating conditions MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications Single screw compressor Highest part load performances in its class STANDARD AVAILABLE Double setpoint Compressor thermal relays Phase monitor Evaporator victaulic kit 0mm evaporator insulation Evaporator electric heater Electronic expansion device Discharge line shut off valve Ambient temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm Fan circuit breakers Main switch interlock Emergency stop s c r e w MicroTech III OPTIONS Total heat recovery Partial heat recovery Brine version Under / overvoltage control Ampere volt meter Current limit - display Evaporator flange kit Fan silent mode Fans speed control device Speedtrol (fan speed control device) Condenser coil guards Evaporator area guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch Suction line shut off valve High pressure sied manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump (3 different models) Two centrifugal pumps (4 different models) Double pressure relief valve with diverter Compressor circuit breakers Fans speed regulation Refrigerant recovery tank Evaporator right water connection Ground fault relay Accessories Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM00J) LON communication module (EKCMLO N) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) 7

73 EWad670-C8cZXS/XL Cooling only Capacity class C0 C C C3 C4 C5 C6 C7 C8 Cooling capacity Nom. kw Capacity control Method Stepless Minimum capacity % Power input Cooling Nom. kw EER ESEER Dimensions Unit HeigtxWidthxDepth mm 540x85x x85x x85x x85x x85x65 540x85x55 540x85x x85x435 Weight Unit (XS) kg Operation weight (XS) kg Weight Unit (XL) kg Operation weight (XL) kg Type Single Pass Shell&Tube Water heat Water volume l exchanger Nominal water flow Cooling l/s Nominal water pressure drop Cooling Heat exchanger kpa Air heat exchanger Type High efficiency fin and tube type with integral subcooler Type Direct propeller type Drive DOL Diameter mm Fan Nominal air flow l/s Quantity No Model Speed rpm Motor input kw Sound power level (XS) Cooling Nom. dba Sound pressure level (XS) Cooling Nom. dba Sound power level (XL) Cooling Nom. dba Sound pressure level (XL) Cooling Nom. dba Compressor Type Semi-hermetic single screw compressor inverter driven Type R-34a Refrigerant circuit Charge kg Circuits Quantity Piping connections Evaporator water inlet/outlet mm Power supply Phase / Frequency / Voltage Hz/V 3~/50/400 73

74 EWad-cZxr Air cooled inverter chiller, high efficiency, reduced sound STRENGTHS Wide capacity range Lower starting current and optimum power factor Wide range of operating conditions MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications Single screw compressor Highest part load performances in its class STANDARD AVAILABLE Double setpoint Compressor thermal relays Phase monitor Evaporator victaulic kit 0mm evaporator insulation Evaporator electric heater Electronic expansion device Discharge line shut off valve Ambient temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm Fan circuit breakers Main switch interlock Emergency stop s c r e w MicroTech III OPTIONS Total heat recovery Partial heat recovery Brine version Under / overvoltage control Ampere volt meter Current limit - display Evaporator flange kit Fan silent mode Fans speed control device Speedtrol (fan speed control device) Condenser coil guards Evaporator area guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil Evaporator flow switch Suction line shut off valve High pressure sied manometers Container kit Rubber anti vibration mount Spring anti vibration mount One centrifugal pump (3 different models) Two centrifugal pumps (4 different models) Double pressure relief valve with diverter Compressor circuit breakers Fans speed regulation Refrigerant recovery tank Evaporator right water connection Ground fault relay Accessories Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM00J) LON communication module (EKCMLO N) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) 74

75 EWad670-C8cZXS/XL Cooling only Capacity class C0 C C C3 C4 C5 C6 C7 Cooling capacity Nom. kw ,03 70,35,33,443,545,63,7 Capacity control Method Stepless Minimum capacity % Power input Cooling Nom. kw EER ESEER Dimensions Unit HeigtxWidthxDepth mm 5450x85x x85x x85x x85x x85x65 540x85x55 540x85x x85x435 Weight Unit kg Operation weight kg Type Single Pass Shell & Tube Water heat Water volume l exchanger - evaporator Nominal water flow Cooling l/s Nominal water pressure drop Cooling Heat exchanger kpa Air heat exchanger Type High efficiency fin and tube type with integral subcooler Type Direct propeller type Drive DOL Diameter mm Fan Nominal air flow l/s Quantity No Model Speed rpm Motor input kw Sound power level (XL) Cooling Nom. dba Sound pressure level (XL) Cooling Nom. dba Compressor Type Semi-hermetic single screw compressor Inverter driven Type R-34a Refrigerant circuit Charge kg Circuits Quantity Piping connections Evaporator water inlet/outlet mm Power supply Phase / Frequency / Voltage Hz/V 3~/50/400 75

76 Condensing Unit The Daikin condensing units can be used in a wide variety of air conditioning, refrigeration and ventilation applications. TABLE OF CONTENTS erad-e-ss 78 erad-e-sl 80 76

77 PIPING DIAGRAM FOR COMFORT COOLING APPLICATION Chiller Air handling unit. Switchbox. Thermistor line

78 ERAD-E-SS Air cooled condensing unit, standard efficiency, standard sound STRENGTHS Wide capacity range ( kw kw) Single refrigerant circuit with single screw compressor Compact design with brazed plate heat exchanger Large operation range (ambient temperature down to -8 C) Water supply down to -5 C STANDARD AVAILABLE Wye delta starter (y - d) Double setpoint Fans circuit breakers with thermal overload relays Phase monitor Discharge line shut off valve Suction line shut off valve Ambient outside temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Fans circuit breakers Main switch interlock s c r e w MicroTech III OPTIONS (factory mounted) Total heat recovery Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Speedtrol Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount Double pressure relief valve with diverter Automatic circuit breakers ACCESSORIES Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM00J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) 78

79 ERAD70,00E-SS Cooling only Indoor units Cooling capacity Nom. kw Capacity control Method Stepless Minimum capacity % 5 Power input Cooling Nom. kw EER Dimensions Unit HeightxWidthxDepth mm,73x,9x,65,73x,9x3,065,73x,9x3,965,3x,36x3,070 Weight Unit kg,584,74,936,679 Operation weight kg,67,78,98,756 Air heat exchanger Type High efficiency fin and tube type with integral subcooler Fan Air flow rate Nom. l/s 0,9 0,575 6,383 5,863,844,50 3,767 3,75 Fan motor Speed Cooling Nom. rpm 90 Sound power level Cooling Nom. dba Sound pressure Cooling Nom. dba level Compressor Type Semi-hermetic single screw compressor Operation range SST Min-Max C -9~ Condenser Min-Max C -8~48 Refrigerant Type R-34a Charge kg Circuits Quantity Power supply Phase / Frequency / Voltage Hz / V 3~ / 50 /

80 ERAD-E-SL Air cooled condensing unit, standard efficiency, low sound STRENGTHS Low operating sound level Wide capacity range (6 kw - 46 kw) Single refrigerant circuit with single screw compressor Compact design with brazed plate heat exchanger Large operation range (ambient temperature down to -8 C) Water supply down to -5 C STANDARD AVAILABLE Wye delta starter (y - d) Double setpoint Fans circuit breakers with thermal overload relays Phase monitor Discharge line shut off valve Suction line shut off valve Ambient outside temperature sensor and set-point reset Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Fans circuit breakers Main switch interlock s c r e w MicroTech III OPTIONS (factory mounted) Total heat recovery Partial heat recovery Soft starter Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Speedtrol Condenser coil guards Cu-cu condenser coil Cu-cu sn condenser coil Alucoat fins coil High pressure side manometers Container kit Rubber anti vibration mount Spring anti vibration mount Double pressure relief valve with diverter Automatic circuit breakers ACCESSORIES Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) ModBus RTU communication module (EKCM00J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/remote Display HMI (EKRUPCS) 80

81 ERAD60,90E-SL Cooling only Indoor units Cooling capacity Nom. kw Capacity control Method Stepless Minimum capacity % 5 Power input Cooling Nom. kw EER Dimensions Unit HeightxWidthxDepth mm,73x,9x,65,73x,9x3,065,73x,9x3,965,3x,36x3,070 Weight Unit kg,684,84,036,789 Operation weight kg,77,88,08,886 Air heat exchanger Type High efficiency fin and tube type with integral subcooler Fan Air flow rate Nom. l/s 8,37 8,44,558,7 6,744 6,89 5,7 4,433 Fan motor Speed Cooling Nom. rpm 75 Sound power level Cooling Nom. dba Sound pressure Cooling Nom. dba level Compressor Type Semi-hermetic single screw compressor Operation range SST Min-Max C -9~ Condenser Min-Max C -8~48 Refrigerant Type R-34a Charge kg Circuits Quantity Power supply Phase / Frequency / Voltage Hz / V 3~ / 50 / 400 8

82 Water Cooled Daikin offers you compact water cooled chiller units which require only very limited space in a machine room. Used for commercial or industrial applications, these chillers generate cold and hot water, which can be used for chilling, heating, or even both at the same time. TABLE OF CONTENTS EWwp-kbwn 84 ewwd-j-ss 86 ewwd-g-ss 88 ewwd-g-xs 90 ewwd-i-ss 9 ewwd-i-xs 94 ewwd-bjynn 96 ewwq-b-ss 98 ewwq-b-xs 00 EWWD-Fzxs 0 DWSC / DWDC 04 8

83 . Balancing valve. Pressure gauge 3. Temperature sensor 4. Drain valve 5. Shut-off valve 6. Fill valve 7. Filter 8. Drain 9. Safety valve 0. Pressure port. Pump. Flow switch 3. Pressure regulating valve 4. Bypass valve P I P I N G D I A G R A M F O R C O M F O R T C O O L I N G A P P L I C AT I O N To fan coil units Expansion vessel Chillers Expansion vessel Buffertank Condenser Evaporator Buffer tank To fan coil units

84 EwWp-kBWN Water cooled chiller STRENGTHS Standard integrated: main switch, water filter, flow switch, air purge, pressure ports Daikin scroll compressor Optimised for use with R-407C Electronic DDC controller Low operating sound level Low energy consumption Extension possible up to 7HP Compact dimensions and low refrigerant volume Easy installation and maintenance Stainless steel plate heat exchanger Remote cooling or heating selection Water/water heat pump, with water reversibility Compatible with hydraulic module µc² SE controller pco 3 controller for assembly of or 3 modules For single module units Standard main isolator switch Basic hydraulic components for KA-series included with the unit as a kit: flow switch, air purge, filter + shut-off valves for both condenser and evaporator OPTIONS (factory mounted) Chilled water temperature down to - 5 C (OPZH) or -0 C (OPZL) ACCESSORIES (kit) Compressor soundproof material (-3dBA) Hydraulic module (see page EHMC-page in this catalogue) BMS gateway (MODBUS/J- BUS / BACNET protocol) Remote user interface CONTROL Microprocessor control Water inlet temperature control Cold water or hot water regulation AVAILABLE INPUTS / OUTPUTS Input Remote ON / OFF Pump contact Cool/heat selection Output Compressor operation Summary alarm Pump relay contact s c r o l l µc SE 84

85 EWWP04-035KBWN EWWP090-30KBWN EWWP45-95KBWN Heating only & Cooling only Capacity class Cooling capacity Nom. kw Heating capacity Nom. kw Capacity steps number 4 6 Power input Cooling Nom. kw EER Dimensions Unit HeightxWidthxDepth mm 600x600x x600x,00,00x600x,00,800x600x,00 Weight Unit kg Operation weight kg - Water heat Type Brazed plate exchanger - Minimum water volume in the system l evaporator Water flow rate Min. l/min Nom. l/min Max. l/min ,05,066,8 Water heat Type Brazed plate exchanger - Water flow rate Min. l/min condenser Nom. l/min Max. l/min ,038,33,9,93,357,4 Sound power level Cooling Nom. dba Compressor Type Hermetically sealed scroll compressor Operation range Evaporator Cooling Min.~Max. CDB -0 (OPZL) ~ 5 Condenser Cooling Min.~Max. CDB 0 ~ 55 Refrigerant Type R-407C Control Thermostatic expansion valve Circuits Quantity 4 6 Refrigerant circuit Charge kg Piping Evaporator water inlet/outlet FBSP 5mm FBSP 40mm x x FBSP 38mm 3 x x FBSP 38mm connections Evaporator water drain Field installation Condenser water inlet/outlet FBSP 5mm FBSP 40mm x x FBSP 38mm 3 x x FBSP 38mm Condenser water drain Field installation Power supply Phase / Frequency / Voltage Hz / V 3N~ / 50 /

86 EwWd-J-SS Water cooled chiller STRENGTHS Compact design to allow easy indoor installation or retrofit operations High efficiency at full and partial load MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications STANDARD Wye-delta starter (y-d) Double set point Phase monitor Evaporator victaulic kit 0 mm evaporator insulation Condenser victaulic kit Condenser Water Side Design 6 bar Condenser passes (dt 4-8 C) Evaporator flow switch Electronic expansion device Discharge line shut off valve Suction line shut off valve High pressure side manometers Hour run meter General fault contactor Main switch interlock Emergency stop s c r e w MicroTech III Options Heat pump version Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit display Condenser double flanges kit 0mm condenser insulation Water pressure differential switch on evaporator Low pressure side manometers Fork-lift kit Rubber anti vibration mount Sound proof system Set-point reset, demand limit and alarm from external device Double pressure relief valve with diverter Automatic circuit breakers Accessories Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) Modbus RTU communication module (EKCM00J) LON communciation module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/Remote Display HMI (EKRUPCS) 86

87 EWWD-J-SS Cooling only Capacity class Cooling capacity Nom. kw Heating capacity Nom. kw Capacity control Method Stepless Minimum capacity % 5.5 Power input Cooling Nom. kw Heating Nom. kw EER COP ESEER Dimensions Unit HeigtxWidthxDepth mm,00x,684x93,000x,684x93 Weight Unit kg,777,33,334,366,46,600,607,668,700,73,78,83 3,06 3,00 3,07 3,5 Operation weight kg,,76,378,45,473,663,675,755,79,830,888,946 3,36 3,37 3,338 3,350 Water Type Brazed plate, one per circuit heat exchanger - Water volume l evaporator Nominal water Cooling Heat kpa pressure drop exchanger Water Type Double pass shell and tube heat exchanger - Water flow rate Nom. l/s condensor Nominal water pressure drop Cooling kpa Sound power level Cooling Nom. kpa Sound pressure level Cooling Nom. dba Compressor Type Semi-hermetic single screw compressor Refrigerant Type R-34a Circuits Quantity Piping Evaporator water inlet/outlet 76.mm connections Condenser water inlet/outlet " / 4" Power supply Phase / Frequency / Voltage Hz / V 3 / 50 /

88 EWWD-G-SS Water cooled chiller, standard efficiency STRENGTHS All models are PED pressure vessel approved Stepless single-screw compressor Optimised for use with R-34a EER range up to 4 - truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator one pass refrigerant side for easy oil circulation and return Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications STANDARD AVAILABLE Wye-delta starter Double set point Phase monitor Evaporator victaulic kit Evaporator water side design pressure 0 bar Condenser water side design 6 bar Electronic expansion device Suction line shut off valve High pressure side manometers Hour run meter General fault contactor OPTIONS (factory mounted) Total heat recovery Partial heat recovery Soft starter Heat pump version Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Condenser double flanges kit 0mm evaporator insulation 0mm condenser insulation Condenser victaulic kit Cu-ni 90-0 condenser tubes Evaporator flow switch Condenser flow switch Fork-lift kit Rubber anti vibration mount Sound proof system Double pressure relief valve with diverter ACCESSORIES Serial sequencing panel (EKDSSP-S) Digital sequencing panel (EKDDSP) Modbus RTU communication module (EKCM00J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/Remote Display HMI (EKRUPCS) s c r e w MicroTech III 88

89 EWWD60G-SS Heating only & Cooling only Indoor units Cooling capacity Nom. kw Heating capacity Nom. kw Capacity control Method Stepless Minimum capacity % 5.5 Power input Cooling Nom. kw Heating Nom. kw EER COP ESEER Dimensions Unit HeightxWidthxDepth mm,860x90x3,435,880x860x4,305 Weight Unit kg,393,40,503,687,697,70,757,76 Operation weight kg,470,480,650,840,850,860,970 Water heat Type Single pass shell and tube exchanger - Water volume l evaporator Nominal water pressure drop Cooling Total kpa Water heat Type Single pass shell and tube exchanger - Water flow rate Nom. l/s condenser Nominal water pressure drop Cooling kpa Sound power level Cooling Nom. dba Sound pressure Cooling Nom. dba level Compressor Type Semi-hermetic single screw compressor Operation range Evaporator Cooling Min.~Max. CDB -8~5 Condenser Cooling Min.~Max. CDB 0~55 Refrigerant Type R-34a Charge kg Control Electronic expansion valve Circuits Quantity Piping Evaporator water inlet/outlet 88.9mm 4.3mm 39.7mm connections Condenser water inlet/outlet 5" Power supply Phase / Frequency / Voltage Hz / V 3 / 50 /

90 EwWd-G-XS Water cooled chiller, high efficiency STRENGTHS High efficiency All models are PED pressure vessel approved Stepless single-screw compressor Optimised for use with R-34a EER range up to truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator one pass refrigerant side for easy oil circulation and return Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications STANDARD AVAILABLE Wye-delta starter Double set point Phase monitor Evaporator victaulic kit Evaporator water side design pressure 0 bar Condenser water side design 6 bar Electronic expansion device Suction line shut off valve High pressure side manometers Hour run meter General fault contactor OPTIONS (factory mounted) Total heat recovery Partial heat recovery Soft starter Heat pump version Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Condenser double flanges kit 0mm evaporator insulation 0mm condenser insulation Condenser victaulic kit Cu-ni 90-0 condenser tubes Evaporator flow switch Condenser flow switch Fork-lift kit Rubber anti vibration mount Sound proof system Double pressure relief valve with diverter ACCESSORIES Serial sequencing panel (EKDSSP-S) Digital sequencing panel (EKDDSP) Modbus RTU communication module (EKCM00J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/Remote Display HMI (EKRUPCS) s c r e w MicroTech III 90

91 EWWD650G-XS Heating only & Cooling only Indoor units Cooling capacity Nom. kw Heating capacity Nom. kw Capacity control Method Stepless Minimum capacity % 5.5 Power input Cooling Nom. kw Heating Nom. kw EER COP ESEER Dimensions Unit HeightxWidthxDepth mm,860x90x3,435,880x860x4,305 Weight Unit kg,650,665,680,800,945,955,975,990 Operation weight kg,800,80,80 3,00 3,80 3,90 3,35 3,340 Water heat Type Single pass shell and tube exchanger - Water volume l evaporator Nominal water pressure drop Cooling Total kpa Water heat Type Single pass shell and tube exchanger - Water flow rate Nom. l/s condenser Nominal water pressure drop Cooling kpa Sound power level Cooling Nom. dba Sound pressure Cooling Nom. dba level Compressor Type Semi-hermetic single screw compressor Operation range Evaporator Cooling Min.~Max. CDB -8~5 Condenser Cooling Min.~Max. CDB 0~55 Refrigerant Type R-34a Charge kg Control Electronic expansion valve Circuits Quantity Piping Evaporator water inlet/outlet 4.3mm 39.7mm 68.3mm connections Condenser water inlet/outlet 5" Power supply Phase / Frequency / Voltage Hz / V 3 / 50 / 400 9

92 EwWd-I-SS Water cooled chiller, standard efficiency STRENGTHS All models are PED pressure vessel approved Stepless single-screw compressor Optimised for use with R-34a Cooling range: 333,50kW EER range: 4.8 to truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator one pass refrigerant side to minimize pressure drops Partial and total heat recovery option available MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications STANDARD AVAILABLE Wye delta starter (y - d) Double set point Phase monitor Evaporator victaulic kit Evaporator water side design pressure 0 bar Condenser water side design 0 bar Electronic expansion device High pressure side manometers Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Condenser pass (dt 4-8 C) OPTIONS (factory mounted) Total heat recovery Partial heat recovery Soft starter Heat pump version Brine version Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Condenser double flanges kit Evaporator water side design pressure 5 bar 0mm evaporator insulation 0mm condenser insulation Condenser victaulic kit Cu-ni 90-0 condenser tubes Condenser passes (dt 9-5 C) Water pressure differential switch on condenser Water pressure differential switch on evaporator Evaporator flow switch Condenser flow switch Discharge line shut off valve Suction line shut off valve Container kit Rubber anti vibration mount Sound proof system Double pressure relief valve with diverter ACCESSORIES Serial sequencing panel (EKDSSP-S) Digital sequencing panel (EKDDSP) Modbus RTU communication module (EKCM00J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/Remote Display HMI (EKRUPCS) s c r e w 9 MicroTech III

93 EWWD-I-SS Heating only & Cooling only Indoor units C0 C C3 C4 C5 C6 C7 C8 Cooling capacity Nom. kw ,07,55,04,74,346,40,455,50 Heating capacity Nom. kw ,07,6,7,363,47,507,7,66,730,790 Capacity control Method Stepless Minimum capacity % Power input Cooling Nom. kw Heating Nom. kw EER COP ESEER Dimensions Unit HeightxWidthxDepth mm,8x,430x3,398,3x,350x4,36,33x,35x4,46 Weight Unit kg,50,60,79,4 3,909 3,97 3,945 3,97 3,996 4,080 4,09 6,079 6,097 6,36 6,74 6,9 6,0 6,8 Operation weight kg,380,396,40,457 4,7 4,8 4,43 4,6 4,88 4,369 4,386 6,68 6,646 6,670 6,699 6,77 6,735 6,76 Water heat Type Single pass shell and tube exchanger - Water volume l evaporator Nominal water Cooling Heat kpa pressure drop exchanger Water heat Type Single pass shell and tube exchanger - Water flow rate Nom. l/s condenser Nominal water pressure drop Cooling kpa Sound power level Cooling Nom. dba Sound pressure Cooling Nom. dba level Compressor Type Semi-hermetic single screw compressor Operation range Evaporator Cooling Min.~Max. CDB -8~5 Condenser Cooling Min.~Max. CDB 0~55 Refrigerant Type R-34a Control Electronic expansion valve Circuits Quantity 3 Refrigerant circuit Charge kg Piping Evaporator water inlet/outlet 68.3mm 9.mm connections Condenser water inlet/outlet 5" Power supply Phase / Frequency / Voltage Hz / V 3 / 50 /

94 EwWd-I-XS Water cooled chiller, high efficiency STRENGTHS High efficiency All models are PED pressure vessel approved Stepless single-screw compressor Optimised for use with R-34a Cooling range: 36,34kW EER range: 4.73 to 5.0 or truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator one pass refrigerant side to minimize pressure drops MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications STANDARD AVAILABLE Wye delta starter (y - d) Double set point Phase monitor Evaporator victaulic kit Evaporator water side design pressure 0 bar Condenser water side design 0 bar Condenser passes (dt 4-8 C) Electronic expansion device High pressure side manometers Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Evaporator pass OPTIONS (factory mounted) Partial heat recovery Soft starter Heat pump version Brine version Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Condenser double flanges kit Evaporator water side design pressure 5 bar 0mm evaporator insulation 0mm condenser insulation Condenser victaulic kit Cu-ni 90-0 condenser tubes Condenser 4 passes Water pressure differential switch on condenser Water pressure differential switch on evaporator Evaporator flow switch Condenser flow switch Discharge line shut off valve Suction line shut off valve Container kit Rubber anti vibration mount Sound proof system Double pressure relief valve with diverter ACCESSORIES Serial sequencing panel (EKDSSP-S) Digital sequencing panel (EKDDSP) Modbus RTU communication module (EKCM00J) LON communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/Remote Display HMI (EKRUPCS) s c r e w MicroTech III 94

95 EWWD-I-XS Heating only & Cooling only Indoor units C0 C C Cooling capacity Nom. kw ,038,34 Heating capacity Nom. kw ,069,6,03,33 Capacity control Method Stepless Minimum capacity % 5.5 Power input Cooling Nom. kw Heating Nom. kw EER COP ESEER Dimensions Unit HeightxWidthxDepth mm,883x,430x4,08,45x,350x4,769 Weight Unit kg,594,667,704 4,964 4,997 5,049 5,073 5,097 5,3 Operation weight kg,998 3,078 3,6 5,58 5,65 5,67 5,695 5,79 5,74 Water heat Type Single pass shell and tube exchanger - Water volume l evaporator Nominal water Cooling Heat kpa pressure drop exchanger Water heat Type Single pass shell and tube exchanger - Water flow rate Nom. l/s condenser Water flow rate Nom. l/min Nominal water Cooling kpa pressure drop Sound power level Cooling Nom. dba Sound pressure Cooling Nom. dba level Compressor Type Semi-hermetic single screw compressor Operation range Evaporator Cooling Min.~Max. CDB -8~5 Condenser Cooling Min.~Max. CDB 0~55 Refrigerant Type R-34a Control Electronic expansion valve Circuits Quantity Refrigerant circuit Charge kg Piping Evaporator water inlet/outlet 68.3mm 9.mm connections Condenser water inlet/outlet 5" Power supply Phase / Frequency / Voltage Hz / V 3 / 50 /

96 EwWd-bjynn Water cooled chiller STRENGTHS Cooling range: 369,050kW Super high efficiency: EER up to 5.8 ; A class energy label Very high EER values at part loads condition (ESEER up to 7.4) and stepless single-screw compressors Optimised for use with R-34a Flooded evaporator Expansion valve with liquid level control All models are PED pressure vessel approved STANDARD AVAILABLE Main switch Gauges Electronic expansion valve Digital controller s c r e w OPTIONS (factory mounted) Glycol application Suction stop valve A / V meter Soft starter Cu / Ni heat exchanger ACCESSORIES Communication cards (EKAC00J EKACBAC EKACLON) Remote user interface (EKRUPCK) Buffer tanks (EKBT500N - EKBTC0N - EKBT500C - EKBTC500C) Daikin serial sequencing panel (EKDSSP) Modem (EKMODEM EKGSMOD) Converter RS485 to RS3 (EKCON) or to USB (EKCONUSB) 96

97 EWWDCBJYNN Cooling only Capacity class C0 C Cooling capacity Nom. kw ,050 Capacity steps % stepless 5-00 Stepless.5-00 Power input Cooling Nom. kw EER ESEER Dimensions Unit HeightxWidthxDepth mm,50x3,65x,55,50x3,860x,55,300x4,45x,743,300x4,45x,808,300x4,45x,90 Weight Unit kg 3,089 3,370 3,603 5,546 5,636 6,007 6,448 6,598 Operation weight kg 3,50 3,588 3,870 5,9 6,045 6,460 6,97 7,63 Water heat Type Flooded shell and tube exchanger - Minimum water volume in the system l evaporator Water flow rate Min. l/min ,6,09,38,63 Nom. l/min,058,76,494,04,339,566,798 3,00 Max. l/min,788,945,455,946 3,846 3,85 4,370 5,6 Nominal water Cooling Heat kpa pressure drop exchanger Water heat Minimum water volume in the system l exchanger - Water flow rate Min. l/min ,086,478,703,904,94,46 condenser Nom. l/min,44,499,75,474,746 3,00 3,77 3,56 Max. l/min,03,998 3,435 4,675 5,386 6,00 6,085 6,786 Nominal water Heating kpa pressure drop Water heat exchanger - heat recovery condenser Type Shell and tube Sound pressure Cooling Nom. dba level Compressor Type Semi-hermetic single screw compressor Operation range Evaporator Cooling Min.~Max. CDB -8 ~ 5 Condenser Cooling Min.~Max. CDB ~ 50 Refrigerant Type R-34a Charge kg Control Electronic expansion valve Circuits Quantity Piping connections Evaporator water drain /" gas Power supply Phase / Frequency / Voltage Hz / V 3~ / 50 /

98 EwWq-B-SS Water cooled chiller, standard efficiency STRENGHTS All models are PED pressure vessel approved or stepless single-screw compressors or truly independent refrigerant circuits Optimised for use with R-40A Standard electronic expansion valve Compact design Partial heat recovery available MicroTech III controller STANDARD AVAILABLE Wye Delta Starter (Y-D) Double setpoint Phase monitor Evaporator victaulic kit Evaporator Water side design pressure 0 bar Evaporator Water side design pressure 6 bar Electronic expansion device High pressure side manometers Hour run meter General fault contactor Set-point reset, demand limit & alarm from external device Double pressure relief valve with diverter s c r e w MicroTech III OPTIONS Partial heat recovery Soft starter Brine version Compressor thermal relays Under/overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display 0mm evaporator insulation 0mm condenser insulation Condenser victaulic kit Cu-ni 90-0 condenser tubes Evaporator electric heater Evaporator flow switch Discharge line shut off valve Suction line shut off valve Container kit Rubber anti vibration mount Sound proof system ACCESSORIES Serial sequencing panel (EKDSSP-S) Digital sequencing panel (EKDDSP) Modbus RTU communication module (EKCM00J) LO N communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/Remote Display HMI (EKRUPCS) 98

99 EWWQC9,C0B-SS Cooling only Capacity class C0 C C C3 C4 C5 C6 C7 C9 C0 Cooling capacity Nom. kw ,007,055,85,55,35,460,584,748,888,050 Capacity control Method Stepless Minimum capacity % 5.5 Power input Cooling Nom. kw EER ESEER Dimensions Unit HeightxWidthxDepth mm,849x,40x3,373,00x,76x3,454,848x,34x3,535,58x,350x5,00,848x,34x,00,58x,350x5,00,848x,34x,00,378x,350x4,894,455x,350x5,070,495x,350x4,89,495x,350x4,865 Weight Unit kg,933,967,83,33,407 3,9,47 3,949 3,988,457 4,344 4,59 4,536 4,607 4,988 4,999 5,053 5,04 5,89 Operation weight kg,35,69,543,68,777 4,4,795 4,463 4,496,8 4,780 5,86 5,00 5,80 5,60 5,65 5,670 5,88 5,970 Water heat Type Shell and tube exchanger - Water volume l evaporator Nominal water pressure drop Cooling Heat exchanger kpa Water heat Type Shell and tube exchanger - Water flow rate Nom. l/s condenser Nominal water pressure drop Cooling kpa Nominal water pressure drop Cooling kpa Sound power level Cooling Nom. dba Sound pressure level Cooling Nom. dba Compressor Type Semi-hermetic single screw compressor Operation range Evaporator Cooling Min.~Max. CDB -4~0 Condenser Cooling Min.~Max. CDB 5~45 Refrigerant Type R-40A Charge kg Control - Circuits Quantity Refrigerant circuit Charge kg Refrigerant circuit Charge kg Piping connections Evaporator water inlet/outlet - - Power supply Phase/Frequency/Voltage Hz/V 3~/50/400 99

100 EwWq-B-XS Water cooled chiller, high efficiency STRENGHTS High efficiency All models are PED pressure vessel approved or stepless single-screw compressors or truly independent refrigerant circuits Shell and tube heat exchanger Optimised for use with R-40A Standard electronic expansion valve Compact design Partial heat recovery available MicroTech III controller STANDARD AVAILABLE Wye Delta Starter (Y-D) Double setpoint Phase monitor Evaporator victaulic kit Evaporator Water side design pressure 0 bar Condenser Water side design pressure 6 bar Electronic expansion device High pressure side manometers Hour run meter General fault contactor Set-point reset, demand limit & alarm from external device Double pressure relief valve with diverter OPTIONS Partial heat recovery Soft starter Brine version Compressor thermal relays Under/overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display 0mm evaporator insulation 0mm condenser insulation Condenser victaulic kit Cu-ni 90-0 condenser tubes Evaporator electric heater Evaporator flow switch Discharge line shut off valve Suction line shut off valve Container kit Rubber anti vibration mount Sound proof system ACCESSORIES Serial sequencing panel (EKDSSP-S) Digital sequencing panel (EKDDSP) Modbus RTU communication module (EKCM00J) LO N communication module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/Remote Display HMI (EKRUPCS) s c r e w MicroTech III 00

101 EWWQC9-CB-XS Cooling only Capacity class C0 C C C3 C4 C5 C6 C7 C9 C0 C Cooling capacity Nom. kw ,037,6,58,70,369,449,573,733,863,00,5 Capacity control Method Stepless Minimum capacity % Power input Cooling Nom. kw EER ESEER Dimensions Unit HeightxWidthxDepth mm,00x,76x3,863,00x,68x3,878,003x,34x3,878,003x,446x3,99,454x,350x5,9,003x,446x3,99,454x,350x5,9,454x,350x5,9,495x,350x4,89,495x,350x4,865 Weight Unit kg,3,403,464,738,407,47 4,775,457 4,83 4,873 4,99 4,969 5,7 5,388 5,408 5,44 Operation weight kg,594,685,745 3,58,85 3,056 5,43 3,086 5,479 5,5 5,546 5,606 5,794 5,843 6,0 6,8 6,4 Water heat Type Shell and tube exchanger - Water volume l evaporator Nominal water pressure drop Cooling Heat exchanger kpa Water heat Type Shell and tube exchanger - Water flow rate Nom. l/s condenser Nominal water pressure drop Cooling kpa Nominal water pressure drop Cooling kpa Sound power level Cooling Nom. dba Sound pressure level Cooling Nom. dba Compressor Type Semi-hermetic single screw compressor Operation range Evaporator Cooling Min.~Max. CDB -4~0 Condenser Cooling Min.~Max. CDB 5~45 Refrigerant Type R-40A Control - Circuits Quantity Refrigerant circuit Charge kg Refrigerant circuit Charge kg Piping connections Evaporator water inlet/outlet - Power supply Phase/Frequency/Voltage Hz/V 3~/50/400 0

102 EwWD-FZXS Water cooled chiller with centrifugal compressor STRENGTHS Wide capacity range from 4 to,048 kw An inverter driven compressor allows the capacity to be adjusted precisely to match variations in room and outside temperatures Top seasonal efficiency (ESEER up to 9.60) Onboard digital electronics provide smart controls STANDARD AVAILABLE Evaporator passes configuration Evaporator Victaulic kit 0 STD Evaporator water side design pressure 0 bar 0mm evaporator insulation Condenser passes configuration Condenser Victaulic kit Condenser water side design pressure 0 bar Electronic expansion valve High pressure side manometers Water pressure differential switch on evaporator and condenser Inverter compressor starter Double pressure relief valve with diverter Current limit Hour run meter General fault contactor Set-point reset,demand limit and alarm from external device centrifugal Options Evaporator /3 passes Evaporator flange kit Evaporator double flange kit Evaporator marine water box (victaulic or flanged) Evaporator water side design pressure bar Condenser /3 passes Condenser flange kit Condenser double flange kit Condenser marine water box (victaulic or flanged) Condenser water side design pressure bar 0mm condenser insulation Cu-Ni 90-0 condenser tubes Evaporator/Condenser Flow switch Suction line shut off valve Energy Meter Rubber type antivibration mounts Sound proof system 0

103 EWWD30-C0FZXS ACCESSORIES Serial Sequencing Panel (EKDSSP) Digital Sequencing Panel (EKDDSP) PlantWatchPRO monitoring system (EKPWPRO) PlantWatchPRO monitoring system (modem & webserver included) EKPWPROM Serial Card RS485/ Modbus (EKAC00J) Ethernet Card BACnet (EKACBAC) Serial Card LON FTT 0 (chiller profile pre-loaded) (EKACLON) Serial Card RS3 Modem Interface (single unit only) (EKACRS3) Web Server Card (EKACWEB) Serial Card BACnet MSTP (EKACBACMSTP) Converter RS485 to RS3 (EKCON) Converter RS485 to USB (EKCONUSB) Fixed modem (EKMODEM) GSM modem(ekgsmod) Remote display kit (EKRUPCK) PlantWatchPro I/O extension module for hardwiring and retrofit (EKPWPROEXT) Gateway web (Ethernet LAN SNMP) (EKGWWEB) Gateway for modem (EKGWMODEM) Cooling only Capacity class Cooling capacity Nom. kw Power input Cooling Nom. kw EER Dimensions Unit HeigtxWidthxDepth mm,00x,684x93,000x,684x93 Weight Unit kg,4,4,37,63,305,489,489,474,500,56,568,6,795,979,979,979 Operation weight kg,38,59,53,8,37,58,58,505,533,56,608,655,845 3,036 3,036 3,036 Water heat Type exchanger - Brazed plate, one per circuit evaporator Sound power level Cooling Nom. dba Sound pressure level Cooling Nom. dba Compressor Type Semi-hermetic single screw compressor Refrigerant Type R-34a Circuits Quantity Piping Evaporator water inlet/outlet connections 3" Power supply Phase / Frequency / Voltage Hz / V 3 / 50 /

104 dwsc/dwdc Water cooled chiller with centrifugal compressor DAIKIN WATER COOLED CHILLERS WITH CENTRIFUGAL COMPRESSORS Single compressor unit up to 4.5MW Dual compressor unit on single circuit up to 9MW Optional variable speed drives (VFD) for superior partload performance Compressor unloading down to 5% for dual compressor units and 0% for single compressor units without hot gas bypass Control flexibility for easy integration into BMS VARIABLE FREQUENCY DRIVE OPTION (VFD) Inverter technology greatly improving part load efficiency Reducing annual energy costs HIGH EFFICIENCY COP up to 7 at full load COP up to at partial load (when coupled with inverter VFD) WIDE CHOICE OF CAPACITIES AND EFFICIENCIES Single compressor D-DWSC: 300 kw - 4,500 kw - Approximately. million possible chiller offerings with combination options of motors, impellers, gears and vessels Dual compressor D-DWDC: 600 kw - 9,000 kw - Approximately 0.75 million possible chiller offerings with combination options of motors, impellers, gears and vessels 04

105 UNMATCHED UNLOADING Unloading to 0% of full load for a D-DWSC single compressor chiller and 5% for a D DWDC dual compressor unit, without using inefficient hot gas bypass. This unloading capability provides improved stability of the chilled water temperature and less harmful cycling of compressors. The movable discharge diffuser increases stability and reduces vibrations. POWER LOSS DAMAGE PROTECTION Power failures do not allow chillers to proceed through their normal shutdown sequence. Poor lubrication at this point can damage the bearings and reduce compressor life. The compressors are equipped with a lubricant reservoir and a piston with a compressed spring which provides pressurized lubricant to the bearings during the cost-down period. Also, the compressors decelerate quickly due to the low inertia. REFRIGERANT STORAGE CAPABILITY The condensers are sized to hold the entire chiller refrigerant charge and are provided with the necessary valves to isolate this charge. This feature eliminates the need for separate storage vessels in most applications. Piston Lubricant reservoir Moveable diffuser closing off impeller discharge area LOW OPERATIONAL SOUND LEVEL Liquid Injection A small amount of liquid refrigerant is taken from the condenser and injected into the compressor discharge area. The liquid droplets absorb sound energy and reduce the compressor's overall operational sound level. The droplets evaporate and reduce discharge superheat. Quieter as chiller unloads Daikin s design results in a reduction in sound levels at lower loads, where most chillers spend most of their operating hours. EXCELLENT PART LOAD EFFICIENCY When one compressor is running, it is able to utilize the heat transfer area of the entire chiller, twice the amount found on a single compressor chiller. This huge amount of surface provides exceptional part load efficiency. The addition of VFDs to the dual compressor chiller produces a very high ARI certified Integrated Part Load Value (IPLV). ONE D-DWDC DUAL COMPRESSOR CHILLER VERSUS TWO SINGLE COMPRESSOR CHILLERS Lower equipment costs than two separate chillers Lower installation cost than two separate chillers Lower annual operating cost than either one large or two small chillers Less equipment room space required than for two separate chillers (smaller footprint) Capacity reduction to 5% of design value Standby redundancy for most of the cooling season options of motors, impellers, gears and vessels PARTIAL LOADS EFFICIENCY FOR,000 KW CENTRIFUGAL UNIT D-D D-D D-D D-D D-DWSC: single compressor D-DWDC: double compressor VFD: compressor inverter Specific selections can vary up or down from this example. 05

106 Condenserless Chiller Daikin offers you flexible and compact chillers with remote condenser, which can be used to satisfy applications with special requirements in the field of available space, sound level or extreme operating conditions. In these exceptional cases, remote condenser solutions can be preferred over standard air cooled or water cooled solutions. TABLE OF CONTENTS EWlp-kbwn 08 ewld-j-ss 0 EWLD-g-ss EWLD-i-ss 4 06

107 . Temperature sensor. Filter 3. Shut-off valve 4. Pump 5. Pressure port 6. Flow switch 7. Drain 8. Pressure gauge 9. Water flow adjusting valve 0. Drain valve. Fill valve. Safety valve PIPING DIAGRAM FOR COMFORT COOLING APPLICATION Gas Chillers Expansion vessel To condenser Liquid Evaporator Buffer tank 7 To fan coil units

108 EWLP-kBWN Water cooled condenserless chiller STRENGTHS Daikin scroll compressor Optimised for use with R-407C Electronic DDC controller Low operating sound level Low energy consumption Compact dimensions and low refrigerant volume Easy installation and maintenance Stainless steel plate heat exchanger Compatible with hydraulic module For EWLP0-065KBWN following components are standard included: main switch, pressure ports, flow switch, filter, shut-off valves and air purge µc² SE controller OPTIONS (factory mounted) Chilled water temperature down to - 5 C (ZH) or -0 C (ZL) ACCESSORIES (kit) Hydraulic module (see EHMC-page in this catalogue) Low noise operation EUW*5KZW (EKLS) Low noise operation EUW*8-4KZW (EKLS) Address card for connection to BMS or remote user interface (EKRUMCA) Remote installed user interface (EKAC0C) CONTROL Microprocessor control Water inlet temperature control AVAILABLE INPUTS / OUTPUTS Input Remote ON / OFF Pump contact Output Compressor operation Summary alarm Pump relay contact s c r o l l µc SE 08

109 EWLP0-030KBWN Cooling only CAPACITY CLASS Capacity Cooling kw Power input Cooling kw Capacity Steps EER Dimensions Height x Width x Depth mm 600 x 600 x x 600 x,00 Weight Machine weight kg Water Heat Exchanger Type Brased plate Evaporator Minimum water volume in the system l Water flow rate Min l/min Nominal l/min Max l/min Compressor Type Hermetically sealed scroll compressor Model Quantity Sound Power Cooling dba Operation Range Evaporator Min~Max CDB -0(OPZL) ~ 0 Condensing temperature Min~Max CDB 5 ~ 60 Refrigerant circuit Refrigerant type R-407C No of circuits Refrigerant control Thermostatic expansion valve Power Supply 3N~/400V/50Hz Piping connections Evaporator water inlet/outlet mm FBSP 5 FBSP 40 Evaporator water drain Field installation Liquid line connection mm 9.5 flare.7 flare x.7 flare Discharge line connection mm.7 flare 9. flare x9. flare 09

110 EWld-J-SS Water cooled condenserless chiller STRENGTHS Compact design to allow easy indoor installation or retrofit operations High efficiency at full and partial load MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications STANDARD Wye-delta starter (y-d) Double set point Phase monitor Evaporator victaulic kit 0 mm evaporator insulation Condenser victaulic kit Condenser Water Side Design 6 bar Condenser passes (dt 4-8 C) Evaporator flow switch Electronic expansion device Discharge line shut off valve Suction line shut off valve Hour run meter General fault contactor Main switch interlock Emergency stop s c r e w MicroTech III Options Brine version Compressor thermal relays Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit display Low pressure side manometers Fork-lift kit Rubber anti vibration mount Sound proof system Set-point reset, demand limit and alarm from external device Double pressure relief valve with diverter Automatic circuit breakers Liquid receiver ACCESSSORIES Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) Modbus RTU communication module (EKCM00J) LON communciation module (EKCMLON) BACnet/MSTP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/Remote Display HMI (EKRUPCS) 0

111 EWLD0J-SS Cooling only Capacity class Cooling capacity Nom. kw Power input Cooling Nom. kw EER Dimensions Unit HeigtxWidthxDepth mm,00x,684x93,000x,684x93 Weight Unit kg,4,4,37,63,305,489,489,474,500,56,568,6,795,979,979,979 Operation weight kg,38,59,53,8,37,58,58,505,533,56,608,655,845 3,036 3,036 3,036 Water heat exchanger - evaporator Type Sound power level Cooling Nom. dba Sound pressure level Cooling Nom. dba Compressor Type Semi-hermetic single screw compressor Refrigerant Type R-34a Circuits Quantity Piping connections Evaporator water inlet/outlet 3" Power supply Phase / Frequency / Voltage Hz / V 3 / 50 / 400

112 EWlD-G-SS Water cooled condenserless chiller STRENGTHS Cooling range: 6-56kW EER range: 3.54 to 3.55 Stepless single-screw compressor Optimised for use with R-34a or truly independent refrigerant circuits Standard electronic expansion valve DX shell and tube evaporator one pass refrigerant side for easy oil circulation and return All models are PED pressure vessel approved MicroTech III controller STANDARD AVAILABLE Wye Delta starter (Y-D) Double setpoint Phase monitor Evaporator victaulic kit Evaporator Water side design pressure 0 bar Electronic expansion device Suction line shut off valve High pressure side manometers Hour run meter General fault contactor s c r o l l MicroTech III OPTIONS Partial heat recovery Soft starter Brine version Compressor thermal relays Under/ overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display 0mm evaporator insulation Evaporator flow switch Fork-lift kit Rubber anti vibration mount Sound proof system Double pressure relief valve with diverter Liquid receiver ACCESSORIES Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) Modbus RTU communication module (EKCM00J) LON communication module (EKCMLON) BACnet/MTSP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/Remote Display HMI (EKRUPCS)

113 EWLD~G-SS Cooling only Indoor units Cooling capacity Nom. kw Capacity steps % stepless 5-00 stepless.5-00 Power input Cooling Nom. kw EER Dimensions Unit HeightxWidthxDepth mm,860x,000x3,700,94x,00x4,400 Weight Unit kg,80,398,44,446,50,506 Operation weight kg,337,56,560,670 Water heat Minimum water volume in the l exchanger - system,5,354,749,938,30,6,365,535,704,884 evaporator Water flow rate Min. l/min Nom. l/min ,009.65,09.50,7.8,363.69, Max. l/min ,09.97,75.7,43.6,540.4,73.,9.80,5.7 Nominal water Cooling Heat kpa pressure drop exchanger Model Quantity Type EV EV EV EV EV EV Type Shell and tube - direct expansion Sound power level Cooling Nom. dba Sound pressure Cooling Nom. dba level Compressor Type Semi-hermetic single screw compressor Operation range Evaporator Cooling Min.~Max. CDB -8~5 Condenser Cooling Min.~Max. CDB 5~60 Refrigerant Type R-34a Charge kg 5 0 Control Electronic expansion valve Circuits Quantity Piping connections Evaporator water inlet/outlet Power supply Phase / Frequency / Voltage Hz / V 3~ / 50 / 400 3

114 EWld-I-SS Water cooled condenserless chiller STRENGTHS Cooling range: 38,4kW EER range: 3.5 to 3.9 Stepless single-screw compressor Optimised for use with R-34a Standard electronic expansion valve DX shell and tube evaporator one pass refrigerant side for easy oil circulation and return All models are PED pressure vessel approved MicroTech III controller for superior control logic and an easy interface with LonWorks, Bacnet, Ethernet TCP/IP or Modbus communications STANDARD AVAILABLE Wye Delta Starter (Y-D) Double setpoint Phase monitor Evaporator victaulic kit Evaporator water side design pressure 0 bar Electronic expansion device High pressure side manometers Hour run meter General fault contactor Set-point reset, demand limit and alarm from external device Evaporator pass s c r e w MicroTech III OPTION Soft starter Brine version Under / overvoltage control Energy meter Capacitors cosfi 0.9 Current limit - display Evaporator water side design pressure 5 bar 0mm evaporator insulation Water pressure differential switch on evaporator Evaporator flow switch Discharge line shut off valve Suction line shut off valve Container kit Rubber anti-vibration mount Sound proof system Double pressure relief valve with diverter Liquid receiver ACCESSORIES Serial Sequencing Panel (EKDSSP-S) Digital Sequencing Panel (EKDDSP) Modbus RTU communication module (EKCM00J) LON communication module (EKCMLON) BACnet/MTSP communication module (EKCMBACMSTP) BACnet/IP communication module (EKCMBACIP) Local/Remote Display HMI (EKRUPCS) 4

115 EWLD~I-SS Cooling only Indoor units C0 C C C3 C4 C5 C6 C7 Cooling capacity Nom. kw ,033,078,5,88,67,39,370,4 Capacity control Method % Stepless Minimum capacity Power input Cooling Nom. kw EER Dimensions Unit HeightxWidthxDepth mm,899x,464x3,4,35x,464x4,39,45x,35x4,46 Weight Unit kg,86,869,884 3,33 3,339 3,347 3,356 3,364 3,4 5,46 5,67 5,88 5,08 Operation weight kg,054,05,056 3,60 3,603 3,604 3,605 3,645 5,667 5,67 5,677 5,680 Water heat Water flow rate Nom. l/min 940.,0.8,7.0,444.8,708.8,883.4,09.8,59.0,436.6,634.6,769.0,96.0 3, ,5.0 3, ,63.8 3,78. 3,97.6 4,076.4 exchanger - Nominal water Cooling Total kpa evaporator pressure drop Type Single pass shell and tube Sound power level Cooling Nom. dba Sound pressure Cooling Nom. dba level Compressor Type Semi-hermetic single screw compressor Operation range Evaporator Cooling Min.~Max. CDB -8~5 Condenser Cooling Min.~Max. CDB 5~60 Refrigerant Type R-34a Charge kg 5 Control Electronic expansion valve Circuits Quantity 3 Piping Evaporator water inlet/outlet connections 68.3mm 9.mm Power supply Phase / Frequency / Voltage Hz / V 3~ / 50 / 400 5

116 dicn Daikin Integrated Chiller Network Daikin chillers can be equipped with Daikin Integrated Chiller Network (DICN) which allows the simultaneous operation of up to 4 chillers as if they were a single unit, in order to deliver the required cooling capacity. This results in precise and efficient capacity control and is also useful for back up purposes, ensuring that the necessary amount of cooling is available and guaranteeing reliable operation of the chiller plant. This function enables a Daikin MW chiller plant to be operated via a single controller. Please note that DICN is only possible within the same series. APPLICABLE SERIES: EWAQ080-60DAYN (R-40A) EWYQ080-50DAYN (R-40A) 6

117 EHMC, EKBT Hydraulic Module, Buffer Tank mh O PUMP CHARACTERISTICS WF (l/min) Water flow LEGENDS Pump characteristics. EHMC30AV080. EHMC0AV080 & EHMC5AV EHMC30AV00 4. EHMC0AV00 & EHMC5AV00 Hydraulic module + filter pressures losses 5. EHMC5/30AV00 & EHMC5/30AV EHMC0AV00 & EHMC0AV080 STRENGTHS 00l buffer tank Freeze-up protection (heater tape) Single pump l expansion vessel Standard dual pressure ports Hydraulic module EHMC-AV Nominal flow l/min Nominal static height mh O Nominal input W 630, ,070,070,090 Dimensions (HxWxD) mm,84x635x688 Machine weight kg Sound power dba 63 Sound pressure dba 5 Power supply V ~/30V/50Hz Operation range Water side C -0 C ~ 55 C Air side CDB -0 C ~ 43 C Piping connections Water inlet/outlet " BSPF " BSPF -/" BSPF Drain connection /" Buffer tank MODEL Description Volume Dimensions Unit weight EKBT Buffer tank with cabinet 00l,84x637x754 86,5 EKBT500N Buffer tank 500l 70x, EKBTC0N Buffer tank,000l 860x,00 00 EKBT500C Buffer tank with cabinet 500l,00x,00x, EKBTC0C Buffer tank with cabinet,000l,00x,450x,

118 Fan Coil Units Fan Coil Units are a highly efficient means of turning a water chiller, heat pump or hot water boiler into an efficient, quiet air conditioning system. These units are an effective solution to provide a comfortable environment for both commercial and residential applications. Daikin offers a wide range of Fan Coil Units for both concealed and exposed applications. Three models are available in flexible application. The only moving part in the units is the fan, making them ideal for use in offices, hotels and at home. The goal is to obtain the right solution, both technically and aesthetically. TABLE OF CONTENTS FAn COIL UNIT - accessories 0 FAn COIL UNIT - CONTROL fwv-dt/df 4 fwl-dt/df 5 fwm-dt/df 6 FWT-bt 8 FWb-bt 9 fwb-jt/jf 30 FWC -bt/bf 3 FWF-BT/BF 3 fwd-at/af 7 8

119 PRODUCT PORTFOLIO Reference kw FWT-BT -pipe cooling heating FWC-BT/BF -pipe 4-pipe cooling heating cooling heating FWF-BT/BF -pipe 4-pipe cooling heating cooling heating FWV-DT/DF -pipe 4-pipe cooling heating cooling heating FWL-DT/DF -pipe 4-pipe cooling heating cooling heating FWM-DT/DF -pipe 4-pipe cooling heating cooling heating FWB-BT -pipe 4-pipe * cooling heating cooling heating FWD-AT/AF -pipe 4-pipe cooling heating cooling heating FWB-JT/JF -pipe 4-pipe cooling heating cooling heating (4-pipe) Measuring conditions (at nominal air flow and ESP) : COOLING air temperature entering the unit: 7 C/9 C water temperature entering the unit 7 C leaving the unit C HEATING room air temperature 0 C for pipe units : water temperature entering 50 C - water flow rate same as for the cooling test for 4 pipe units : water temperature entering 70 C - water temperature leaving 60 C. * 4-pipe= -pipe + option additional heat exchanger 9

120 Fan Coil Unit - accessories Type: FWM-DT/DF, FWL-DT/DF, FWV-DT/DF FWV FWL FWM Description Additional single row heat ESRH0A6 ESRH03A6 ESRH06A6 ESRH0A6 x x x exchanger Electric heater EEH0A6 EEH0A6 EEH03A6 EEH06A6 EEH0A6 x x x -pipe 3-way valve EMV03A6 EMV06A6 EMV0A6 x x x 4-pipe 3-way valve E4MV03A6 E4MV06A6 E4MV0A6 x x x Fan stop thermostat YFSTA6 x x x Air intake & discharge grille EAIDF0A6 EAIDF03A6 EAIDF06A6 EAIDF0A6 - - x Supporting feet ESFV06A6 ESFV0A6 x - x Supporting feet + grille ESFVGA6 ESFVG3A6 ESFVG6A6 ESFVG0A6 x - - Fresh air intake EFAA6 EFA3A6 EFA6A6 EFA0A6 x - - Rear panel ERPVA6 ERPV3A6 ERPV6A6 ERPV0A6 x x - Control electromechanical ECFWMB6 x x x Electronic controller FWECA, FWECA, FWEC3A x x x Master slave option EPIMSB6 x x x Vertical drainpan EDPVA6 x x x Horizontal drainpan EDPHA6 - x x On board installation kit FWECKA x x - Temperature sensor kit FWTSKA x x x Relative humidity sensor kit FWHSKA x x x On board FCU controller installation kit FWECKA x x - Type: FWB-BT Description Additional heat exchanger EAH04A6 EAH07A6 EAH0A6 3-way valve add. h/e EMV307A6 EMV30A6 3-way valve cooling h/e Factory mounted -way valve add. h/e EMV07A6 EMV0A6 -way valve cooling h/e Factory mounted Electric Heater Factory mounted Fan stop thermostat YFSTA6 Power interface - - EPIB6 Master slave interface EPIMSB6 Electronic controller FWECA FWECA FWEC3A Temperature sensor kit FWTSKA Relative humidity sensor kit FWHSKA On board installation kit FWECKA Type: FWB-JT/JF Description -pipe 3-way valve 4-pipe 3-way valve MCWCN MCWHN Type: FWD-AT/AF Description Electric heater: small EDEH04A6 EDEHS06A6 EDEHS0A6 EDEHSA6 EDEHS8A6 () Electric heater: big EDEH04A6 EDEHB06A6 EDEHB0A6 EDEHBA6 EDEHB8A6 -pipe 3-way valve EDMV04A6 EDMV0A6 EDMVA6 EDMV8A6 () 4-pipe 3-way valve ED4MV04A6 ED4MV0A6 xedmva6 x EDMV8A6 Vertical Drainpan EDDPV0A6 EDDPV8A6 Horizontal Drainpan EDDPH0A6 EDDPH8A6 Fan stop thermostat YFSTA6 Fresh air intake EDMFA04A6 EDMFA06A6 EDMFA0A6 EDMFAA6 EDMFA8A6 FWECA Electronic controller (3) FWECA FWEC3A Power interface EPIB6 Master slave interface EPIMSA6 Temperature sensor kit FWTSKA Relative humidity sensor kit FWHSKA TYPE Description FWT FWC-BT/BF FWF-BT/BF Standard wired remote control MERCA - - Simplified wired remote control SRC-COB - - Simplified wired remote control SRC-HPB - - Wireless control for cooling only WRC-COB - - Wireless control for heat pump WRC-HPB - - Decoration Panel (RAL grey sealings) 4-way blow - - BYFQ60B Decoration Panel - Standard (RAL grey sealings) - BYCQ40CW Round flow Decoration Panel - White (RAL white sealings) Round - BYCQ40CWW flow Sealing member of air discharge outlet - KDBHQ55C40 KDBH44BA60 Panel spacer - - KDBQ44B60 Long-life filter - KAFP55K60 KAFQ44BA60 Fresh air intake kit - Direct installation type - - KDDQ44XA60 KDDQ55C40- Fresh air intake kit (0% fresh (*0) / - air) - Direct installation type KDDQ55C40- - (*0) Remote controller - Wireless - H/P - BRC7F53F (*8) BRC7E530 (*8) Remote controller - Wireless - C/O - BRC7F533F (*8) BRC7E53 (*8) Remote controller - Wired - BRC35D7 (*4) Central remote controller - DCS30CA5 (*5) Electrical box with earth terminal (3 blocks) - KJB3A Unified on/off controller - DCS30BA5 (*9) Electrical box with earth terminal ( blocks) - KJBA Schedule timer - DST30BA5 DST30BA5 (*6)(*9) (*6)(*9) Wiring adapter for electrical - appendices () (*) (*) KRPA5 (*7) KRPA5 (*9) Wiring adapter for electrical KRP4AA53 (*7) KRP4AA53 (*9) - appendices () (*) (*) Installation box for adapter PCB - KRPH98 (*3) KRPBA0 (*7) Remote sensor - KRCS0-4 KRCS0- Intelligent touch controller - DCS60C5C(*6) DCS60C5C (*6) (*) (*) Electrical installation box - KJB4A Optional PCB for MOD-bus EKFCMBCB7 (*8) EKFCMBCB7 (*8) - connection (*) (*) -way valve - On/Off - EKMVC09B7 (*8) (*0) (*5) EKMVC09B7 (*8) (*0) (*6) 3-way valve - On/Off - EKMV3C09B7 (*8) (*0) (*5) EKMV3C09B7 (*8) (*0) (*6) Valve control PCB - EKRPC Remote On/Off and forced off kit - EKROROA (*7). Requires electronic controller. For FWD,6,8AT/AF only motor valve (piping not included) 3. Water probe included 4. Optional, electrical installation box with earth terminal KJBA is required, if controller wires need to be installed in the wall. 5. Requires electrical installation box with earth terminal KJB3A. 6. Requires electrical installation box KJB4A. 7. Requires installation box KRPH98. (FWC) 8. Requires installation box KRPBA0 (FWF) 9. Requires electrical installation box with earth terminal KJBA, if built in the wall. 0. Requires valve control PCB EKRPC. I-touch: Not allowed to use the i-touch for an installation with both fan coils and VRV units. Can not be used in combination with fan coil units, that use MOD bus communication. No Airnet or telephone connection possible.». Only of these 4 options can be installed on indoor unit. 3. Max. KRPH98 box can be mounted on the unit. Max. PCB s can be mounted in KRPH98 box. (FWC) 4. Max. KRPBA0 boxes can be mounted on the unit. Max. PCB can be mounted in KRPBA0 box. (FWF) 5. -pipe unit: x valve kit + x installation box for PCB KRPH98 + x valve control PCB EKRPC 4-pipe unit: x valve kit + x installation box for PCB KRPH98 + x valve control PCB EKRPC (FWC) 6. -pipe unit: x valve kit + x installation box for PCB KRPBA0 + x valve control PCB EKRPC 4-pipe unit: x valve kit + x installation box for PCB KRPBA0 + x valve control PCB EKRPC (FWF)» 7. This option is needed to create T T wire. 8. It is possible to change the operation mode, but this will not have an impact on the water temperature. (No feed back to water source) It is not possible to select the auto airflow setting. Dry operation can be selected with this remote control, but this function is not available on the FWC model. 9. All options are supplied as kit. 0. Both parts of the fresh air intake are needed for each unit. 0

121

122 Fan Coil Unit - control The fan coil units can be operated by different controllers according to the model. ECFWMB6 BRC35D7 BRC7E53F ELECTROMECHANICAL BUILT-IN CONTROLLER Fan speed selector Manual cooling/heating changeover. ON / OFF valves can also be controlled with ECFWMB6 WIRED REMOTE CONTROLLER to control each fan coil unit independently cooling and heating function ON/OFF timer function INFRARED REMOTE CONTROLLER to control each fan coil unit independently cooling and heating function FWECA FWECA FWEC3A ELECTRONIC Controller Control of on-off valves for two or four pipes systems Control of auxiliary heating element Cooling/heating switching in the following modes: local or remote manual (centralised), automatic (depending on water temperature (optional) or air temperature) Possibility, by means of clean contacts, of remote centralised cooling/heating switching and external activation Temperature sensor kit (accesory FWTSKAA) Economy function (setpoint correction by.5 C and forcing of the fan to run at minimum available speed) Composed by: lc display keyboard On board and wall mounted installation. Same as FWECAA with following additional functions: ) humidity management: - display of relative humidity - dehumidification function (cooling mode) Manual activation ) serial communication interface (RS485 bus) - possibility to set up a masterslave system up to 47 slave units, inwhich one of the controls plays the role of master and manages all the other slave units. ( modbus protocol ) Composed by: lc display keyboard On board and wall mounted installation. Same as FWECAA with following additional functions: ) Back light ) Proportional valve control (two voltage outputs for the proportional valves) 3) Voltage contact 0-0V (same as ) 4) Time clock and weekly schedule (on / off or setpoint air) 5) Integration in BMS (already included in the FWECAA version) 6) Two digital outputs (voltage free) to manage electric heaters with the weekly schedule

123 MERCA STANDARD WIRED REMOTE CONTROLLER Fan speed Sleep function Swing Temperature setting Operating mode LCD display ON / OFF switch Real time clock Timer active Timer ON / OFF SRC-COB SRC-HPB SIMPLIFIED WIRED REMOTE CONTROLLER FOR COOLING ONLY & HEAT PUMP Temperature display Temperature setting Timer switch setting ON / OFF switch Fan speed Operating mode Swing Sleep function WRC - COb/HPB WIRELESS CONTROLLER FOR COOLING ONLY & HEATPUMP LCD display Temperature setting Operating mode Timer switch setting Turbo mode Swing Sleep function Real time clock ON / OF switch Fan speed 3

124 FWV-DT/DF Floor standing unit FWV0, 0DT/DF FWEC,, 3A ECFWMB6 Low sound power levels and electrical absorption thanks to plastic impeller, ABS winding staircase and improved electric motor Quick fixing system for wall mounted installation Pre-assembled 3-way/4-port ON/OFF valves are available Valve packages are insulated, no extra drain pan required Valve packages contain balancing valves and sensor pocket Fast-on connections for electrical options : no tools needed Quick removal of washable filter Electric heater : no relay up to kw capacity Electronic controller with water probe, available in standard, advanced and advanced plus version Indoor units -PIPE 4-PIPE Cooling capacity Total capacity High kw Sensible High kw capacity Heating capacity -Pipe High kw Pipe High kw Power input High W Dimensions Unit HeightxWidthxDepth mm 564x774x6 564x984 x6 564x,94x6 564x,404x5 564x774x6 564x984 x6 564x,94x6 564x,404x5 Weight Unit kg Heat exchanger Water volume l Additional heat Water volume l exchanger Water flow Cooling l/h ,54, ,4,355 Heating l/h ,54, Water pressure Cooling kpa drop Heating kpa Fan Type Centrifugal multi-blade, double suction Centrifugal multi-blade, double suction Air flow rate High m³/h ,0, ,36 Sound power level High dba Piping connections Drain OD mm 6 6 Water connections Std. heat exchanger inch / 3/4 / 3/4 Power supply Phase / Frequency / Voltage Hz / V / 50 / 30 / 50 / 30 Current input High A

125 FWL-DT/DF Flexi type unit FWL03DT/DF FWL03DT/DF FWEC,, 3A ECFWMB6 Low sound power levels and electrical absorption thanks to plastic impeller, ABS winding staircase and improved electric motor Quick fixing system for wall or ceiling mounted installation Pre-assembled 3-way/4-port ON/OFF valves are available Valve packages are insulated, no extra drain pan required Valve packages contain balancing valves and sensor pocket Fast-on connections for electrical options : no tools needed Quick removal of washable filter Electric heater : no relay up to kw capacity Electronic controller with water probe, available in standard, advanced and advanced plus version Indoor units -PIPE 4-PIPE Cooling capacity Total capacity High kw Sensible High kw capacity Heating capacity -Pipe High kw Pipe High kw Power input High W Dimensions Unit HeightxWidthxDepth mm 564x774x6 564x984 x6 564x,94x6 564x,404x5 564x774x6 564x984 x6 564x,94x6 564x,404x5 Weight Unit kg Heat exchanger Water volume l Additional heat Water volume l exchanger Water flow Cooling l/h ,54, ,4,355 Heating l/h ,54, Water pressure Cooling kpa drop Heating kpa Fan Type Centrifugal multi-blade, double suction Centrifugal multi-blade, double suction Air flow rate High m³/h ,0, ,36 Sound power level High dba Water connections Std. heat exchanger inch / 3/4 / 3/4 Power supply Phase / Frequency / Voltage Hz / V / 50 / 30 / 50 / 30 Current input High A

126 FWM-DT/DF Flexi type unit FWM0, 0DT/DF FWM0, 0DT/DF FWEC,, 3A Low sound power levels and electrical absorption thanks to plastic impeller, ABS winding staircase and improved electric motor Quick fixing system for wall or ceiling mounted installation Pre-assembled 3-way/4-port ON/OFF valves are available Valve packages are insulated, no extra drain pan required Valve packages contain balancing valves and sensor pocket Fast-on connections for electrical options : no tools needed Quick removal of washable filter Electric heater: no relay up to kw capacity Electronic controller with water probe, available in standard, advanced and advanced plus version Indoor units -PIPE 4-PIPE Cooling capacity Total capacity High kw Sensible High kw capacity Heating capacity -Pipe High kw Pipe High kw Power input High W Dimensions Unit HeightxWidthxDepth mm 535x584x4 535x794x4 535x,004x4 535x,4x49 535x584x4 535x794x4 535x,004x4 535x,4x49 Weight Unit kg Heat exchanger Water volume l Additional heat Water volume l exchanger Water flow Cooling l/h ,54, ,4,355 Heating l/h ,54, Water pressure drop Cooling kpa Heating kpa Fan Type Centrifugal multi-blade, double suction Centrifugal multi-blade, double suction Air flow rate High m³/h ,0, ,36 Sound power level High dba Piping Drain OD mm connections 7 7 Water connections Std. heat exchanger inch / 3/4 / 3/4 Power supply Phase / Frequency / Voltage Hz / V ~ / 50 / 30 ~ / 50 / 30 Current input High A

127 FWD-AT/AF Flexi type unit FWD04AT/AF FWD04AT/AF FWEC,,3A Quick fixing system for wall or ceiling mounted installation Straight duct connector is mounted to discharge side Electronic controller with water probe, available in standard, advanced and advanced plus version The air filter can easily be removed for cleaning Indoor units -PIPE 4-PIPE Cooling capacity Total capacity High kw Sensible capacity High kw Heating capacity -Pipe High kw Pipe High kw Power input High W , ,97 Dimensions Unit HeightxWidthxDepth mm 80x754x559 80x964x559 80x,74x559 35x,74x78 35x,384x78 80x754x559 80x964x559 80x,74x559 35x,74x78 35x,384x78 Weight Unit kg Heat exchanger Water volume l Additional heat Water volume l exchanger Water flow Cooling l/h 674,064,339,54,056,833 3,40 674,064,339,54,056,833 3,40 Heating l/h 674,064,339,54,056,833 3, ,39,856 Water pressure drop Cooling kpa Heating kpa Fan Type Centrifugal multi-blade, double suction Centrifugal multi-blade, double suction Air flow rate High m³/h 800,50,600,00 3, ,50,600,00 3,000 Available pressure High Pa Sound power level High dba Piping connections Drain OD mm 6 6 Water connections Std. heat exchanger inch 3/4 3/4 Power supply Phase / Frequency / Voltage Hz / V ~ / 50 / 30 ~ / 50 / 30 Current input High A

128 FWT-BT Wall mounted unit FWT05, 06BT MERCA SRC-COB/HPB WRC-COB/HPB Wide operating range Easy installation and maintenance 3-speed fan motor Double-intake centrifugal fans Excellent air flow and air distribution Flexibility via interchangeable water connection side High power air flow Insulated with self-extinguishing class heat insulation Removable washable air filter (self-extinguishing class ) Slim and compact aesthetic design Wireless remote control up to 9m distance, availability of a wired or simplified controller LED indicator gives an indication on the (normal or wrong) operation of the unit Indoor units -PIPE Cooling capacity Total capacity High kw Sensible High kw capacity Heating capacity -Pipe High kw Power input High W Dimensions Unit HeightxWidthxDepth mm 60x799x98 60x899x98 304x,06x Weight Unit kg 0 6 Operation weight kg Heat exchanger Water volume l Water flow Cooling l/h Heating l/h Water pressure drop Cooling kpa Heating kpa Fan Type Centrifugal-direct driven fan motor Air flow rate High m³/h ,070, Sound power level High dba Sound pressure level High dba Piping connections Drain OD mm 6 0 Water connections Std. heat exchanger inch / Power supply Phase / Frequency / Voltage Hz / V ~ / 50 / 0-40 Current input High A

129 FWB-BT Concealed ceiling unit FWB04BT FWEC,, 3A Low sound power levels and electrical absorption thanks to plastic impeller, ABS winding staircase and improved electric motor Compact dimensions, can easily be mounted in a narrow ceiling void 3, 4 or 6 stage row cooling coil Drain pan to collect the condensate from: heat exchanger and regulating valves 7-speed electrical motors (with thermal protection on windings) All 7 speeds pre-wired in the factory in the terminal block of the switch box The air filter can easily be removed for cleaning Indoor units -PIPE Cooling capacity Total capacity High kw Sensible capacity High kw Heating capacity -Pipe High kw Pipe High kw Power input High W Dimensions Unit HeightxWidthxDepth mm 39x,039x609 39x,389x609 39x,739x609 Weight Unit kg Operation weight kg Heat exchanger Water volume l Additional heat Water volume l exchanger Water flow Cooling l/h ,,99,488,774 Heating l/h ,077,39,479,647 Additional heat exchanger l/h 75 56,3 Water pressure drop Cooling kpa Heating kpa Additional heat exchanger kpa Fan Type Centrifugal - forward blades - directly coupled on fan motor Air flow rate High m³/h ,00 Available pressure High Pa Sound power level High dba Sound pressure level High dba Piping connections Drain OD mm 6 Water connections Std. heat exchanger inch 3/4 Add. heat exchanger inch 3/4 Power supply Phase / Frequency / Voltage Hz / V ~ / 50 / 30 Current input High A

130 FWB-JT/JF Concealed ceiling unit FWB0JT/JF FWEC,, 3A Wide operating range Quiet operation via enlarged fan wheels Easy maintenance: filter can be removed from both sides and beneath (maximum filter size is 400mm) Flexibility (-pipe or 4-pipe) 4-speed fan motor Direct driven centrifugal fans Flexibility via interchangeable water connection side High power air flow Available static pressure of 30 Pa Extended drain pan as standard Standard Filter Standard Plenum Insulated with self-extinguishing class heat insulation Electronic room thermostat Indoor units -PIPE 4-PIPE Indoor units -PIPE 4-PIPE Cooling capacity Total capacity High kw Sensible capacity High kw Heating capacity -Pipe High kw Pipe High kw Power input High W Dimensions Unit HeightxWidthxDepth mm 5x84 5x984 5x,4x590 5x,34 5x,564x590 5x,664 5x84 5x984 5x,4 5x,34 5x,564 5x,664 5x,94 5x,94x590 x590 x590 x590 x590 x590 x590 x590 x590 x590 x590 x590 Weight Unit kg Operation weight kg Heat exchanger Water volume l Water flow Cooling l/h ,0,09,383,53,764, ,38,96,660 Heating l/h ,00,07,336,54,764, ,39,99,660 Additional heat exchanger l/h ,4 Water pressure Cooling kpa drop Heating kpa Additional heat exchanger kpa Fan Type Direct driven centrifugal fan (forward-curved blades)hot-galvanised steel Air flow rate High m³/h ,066,463, ,,385 Available pressure High Pa Sound power level High dba Sound pressure level High dba Piping connections Drain OD mm ,04,4,464,564, ,04,4,464,564,84 Water connections Std. heat exchanger inch 3/4 3/4 Power supply Phase / Frequency / Voltage Hz / V ~ / 50 / 0-40 ~ / 50 / 0-40 Current input High A

131 FWC-BT/BF Round flow cassette FWC-BT/BF BRC35D7 BRC7E53F 360 air discharge ensures uniform air flow and temperature distribution Modern style decoration panel in white (RAL900) Fresh air intake for healthy living Comfortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling Possibility to shut or flaps for easy installation in corners Standard drain pump with 850mm lift Indoor unit FWC06B7TVB FWC07B7TVB FWC08B7TVB FWC09B7TVB FWC06B7FVB FWC07B7FVB FWC09B7FVB FWC08B7FVB Cooling capacity Total capacity High kw Sensible High kw capacity Heating capacity -Pipe High kw Pipe High kw Power input High W Dimensions Unit HeightxWidthxDepth mm 88x840x840 88x840x840 Weight Unit kg Water pressure Cooling kpa drop Heating kpa Fan Type Turbo fan Turbo fan Air flow rate High m³/h,06,36,58,776,03,00,746,476 Sound power level High dba Sound pressure High dba level Power supply Phase/Frequency/Voltage Hz/V ~/50/0-40 ~/50/0-40 3

132 FWF -BT/BF 4-way blow ceiling mounted cassette FWF-BT/BF BRC35D7 BRC7E53F Modern stylish decoration panel in white (RAL900) Fresh air intake kit available Comfortable horizontal air discharge ensures draughtfree operation and prevents ceiling soiling Possibility to close or flaps for different air flow patterns Drainpump standard mounted (lift: 750mm) Indoor units -PIPE 4-PIPE Cooling capacity Total capacity High kw Sensible capacity Heating capacity -Pipe High kw Pipe High kw Power input High kw Dimensions Unit HeightxWidthxDepth mm 85x575x575 85x575x575 Weight Unit kg Water pressure drop Cooling kpa Heating Fan Type Turbo fan Turbo fan Air flow rate High m³/h Sound power level High dba Sound pressure level High dba Power supply Phase / Frequency / Voltage Hz / V ~ / 50 / 0-40 ~ / 50 / 0-40 * Height included switch box 3

133

134 Daikin Air handling units D-AHU Professional The D-AHU Professional is based on a completely modular design, capable of adapting to the needs of a variety of installation types. A wide standard range covers air flow rates from,00m³/h up to 4,000m³/h while paying special attention to energy efficiency. System highlights Custom modular design with variable dimensioning Rigid 40mm and 60mm extruded aluminium profile structure Double wall 5mm and 50mm foam or rockwool filled panels Component flexibility for total air treatment: Heat Recovery & Humidification Air flow rates from,00 up to 4,000m 3 /h Aluminium profile with thermal break Robust thermal-break construction The air handling unit is constructed of aluminium, using anodised aluminium profiles and double-walled panels. The profiles have a section of 40x40mm or 60x60mm. The 60x60mm profiles are also available in a thermal-break version. The following insulation material is used between the sheets: Polyurethane foam (40-50 kg/m 3 ) Mineral wool, glued to the panel (90 kg/m 3 ) The panels are available as flat panels or as step panels, which permit to obtain a flat surface inside the unit. The inner and outer sheet of the panel can be made with the following materials: Plastisol Galvanised steel Aluminium Stainless steel Pre-painted D-AHU Professional 0-09 D-AHU Professional 0-8 D-AHU Professional 9-7 Model size Model size Model size Speed.0 m/s Speed.5 m/s Speed 3.0 m/s Speed 3.5 m/s Speed.0 m/s Speed.5 m/s Speed 3.0 m/s Speed 3.5 m/s Speed.0 m/s Speed.5 m/s Speed 3.0 m/s Speed 3.5 m/s Air flow rate (m 3 /h) x,000 Air flow rate (m 3 /h) x,000 Air flow rate (m 3 /h) x,

135 DAIKIN AIR HANDLING UNITS «O ffering a complete range: from standard model sizes to customised solutions.» COMPONENTS OF THE D-AHU PROFESSIONAL Humidifiers Surface evaporation humidifier Water spray humidifier Steam humidifier (on network with generator) Atomized water spray humidifier Centrifugal fans Forward bladed fans Backward bladed fans Centrifugal fan Belt or direct drive Heat exchangers Material: - Cu/Al - Cu/Al prepaint - Cu/Cu - galvanised Fe - RVS304 - RVS36 Water coil Steam coil Direct expansion coil Superheated water coil Electric coils Damper Other Damper Mixed section Empty section Gas burner section Drip tray Heat recovery wheel Heat recovery Heat wheel ( efficiency 70-75%) Plate heat exchanger (efficiency 50-60%) Twincoil heat exchanger (efficiency 50-60%) Filters Pre-filters: - Pleated filter (G3,G4) - Flat filter (G,G) Medium efficiency filter: - Bag filters (rigid or soft) (F5 - F9) High efficiency filters (up to H3) Active carbon filters - Adsorption filters - Deodorizing filters BASIC SPECIFICATIONS Model size Air flow rate at.5m/s Length Height, , , ,570, ,70, ,550, ,000, ,800, ,560, ,600, ,950,550,00 9,30,650,00 3 0,050,650,50 4 3,00,850, ,00,00, ,300,650, ,500,750, ,000 3,0, ,400 3,090,00 0 5,300 3,340,50 58,000 3,80,50 67,500 4,040, ,000 4,490, ,700 4,490, ,890,850 6,000 5,490, ,000 5,990 3,000 35

136 DAIKIN AIR HANDLING UNITS D-AHU Easy Range The range covers an area of air flow rates from 500 m 3 /h up to m 3 /h*, with the possibility to choose the more appropriate face velocity, depending on the treatment required. Pre defined sizes Fifteen fixed sizes optimized to reach the best compromise b.etween competitiveness and manufacturing standardization Variable Dimensioning TM Designed to overcome installation constraints where space requirements of the section height x width must be adapted to the available space. The system gives the possibility to tailor the unit sizes through increments of 5 cm average. Pre defined sizes - Overall dimension Size Std Std Std 3 Std 4 Std 5 Std 6 Std 7 Std 8 Std 9 Std 0 Std Std Std 3 Std 4 Std 5 Air Flow (m 3 /h) Speed.5 m/s Height - mm Width - mm Example Air Flow (m 3 /h) Unit Size STD 5.500x.700 Infinitely variable sizes Height - mm Width - mm Flexible sizing for AHU optimization 5 cm increment for width & height dimensions No additional cost for non-standard unit size No additional lead time Face Velocity m/s *Air Flow limits of 500 m 3 /h and m3/h are calculated using non standard sizes (max dimensions.50x.50) and considering,5 m/s coil face velocity D-AHU Easy -8 D-AHU Easy Size Size Speed.0 m/s Speed.0 m/s.550 Speed.5 m/s Speed.5 m/s.05 (m 3 /h) (Speed.5 m/s) Speed 3.0 m/s (m 3 /h) (Speed.5 m/s) Speed 3.0 m/s Air Flow /000 (m 3 /h) Air Flow /000 (m 3 /h) 36

137 DAIKIN AIR HANDLING UNITS D-AHU Easy UNIT FEATURES Panels Hot injected Polyurethane panels to achieve excellent performance in terms of thermal insulation. Optimized air face velocity Automatic dimensioning of section in order to guarantee an optimal air face velocity on coils and optimized unit cost. Construction The exclusive fixing method used for panels and profiles will ensure an uniform pressure on the whole profile length. That feature will improve significantly the air leakage rate. Internal surface Completely smooth internal surface. Special gaskets utilization of special gasket will ensure internal insulation of the profiles and will help to improve the thermal bridging factor. Unit competitiveness through Variable DimensioningTM exclusive design our clients are sure to invest only for the most optimized panel surface needed to match their requirements. 37

138 ERQ Air handling application (pair) A range of R-40A inverter condensing units for pair application with air handling units. Inverter controlled units Large capacity range (from 00 to 50 class) Heat pump R-40A Flexible control possibilities: - Control x: control of air temperature (discharge temperature, suction temperature, room temperature) via external device (DDC controller) - Control y: control of evaporating temperature via Daikin control (no DDC controller needed) - Control z: control of air temperature (suction temperature, room temperature) via Daikin control (no DDC controller needed) Wide range of expansion valve kits available Air handling unit Liquid pipe Liquid pipe Gas pipe Gas pipe Expansion valve kit : EKEXV F,F communication Control box (cooling only): EKEQDCB : control z EKEQFCB : control x,y gas pipe liquid pipe F-F other communication DDC controller (field supplied) control x COMBINATION TABLE Outdoor unit Control box Expansion valve kit control z control x or y class 63 class 80 class00 class 5 class 40 class 00 class 50 EKEQDCBA EKEQFCBA EKEXV63 EKEXV80 EKEXV00 EKEXV5 EKEXV40 EKEXV00 EKEXV50 ~ 3~ ERQ00AV P P P P P P ERQ5AV P P P P P P P - - ERQ40AV P P - P P P P - - ERQ5AW P P P P P P P - - ERQ00AW P P - - P P P P P ERQ50AW P P P P P P P: Pair: Combination depending on air handling units coils volume. x: Possibility to connect. 38

139 Outdoor unit combined with indoor units Air handling unit ERQ Control box Expansion valve kit Outdoor units ERQ00AV ERQ40AV ERQ5AV Capacity range HP Cooling capacity Nom. kw Heating capacity Nom. kw Power input Cooling Nom. kw Heating Nom. kw EER COP Dimensions Unit HeightxWidthxDepth mm Weight Unit kg Fan-Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power level Cooling Nom. dba Sound pressure level Cooling Nom. dba Heating Nom. dba Operation range Cooling Min./Max. CDB Heating Min./Max. CWB -0/5.5 Refrigerant Type R-40A Piping Liquid OD mm connections Gas OD mm Drain OD mm Power supply Phase / Frequency / Voltage Hz / V Outdoor units ERQ5AW ERQ00AW ERQ50AW Capacity range HP Cooling capacity Nom. kw Heating capacity Nom. kw Power input Cooling Nom. kw Heating Nom. kw EER COP Dimensions Unit HeightxWidthxDepth mm,680x635x765,680x930x765 Weight Unit kg Fan-Air flow rate Cooling Nom. m³/min Heating Nom. m³/min Sound power level Nom. dba 7 78 Sound pressure Nom. dba level Operation range Cooling Min./Max. CDB -5/43 Heating Min./Max. CWB -0/5 Refrigerant Type R-40A Piping Liquid OD mm connections Gas OD mm Power supply Phase / Frequency / Voltage Hz / V ,345x900x / x3 N~ / 50 / N~ / 50 /

140 measuring conditions CHILLERS Cooling Water 7 C / C Ambient temperature : 35 C Air cooled Heating Water 45 C / 50 C Ambient temperature : 7 C Condensing unit Suction dewpoint : 5 C Ambient temperature : 35 C Condensing temp : 45 C Condenserless chiller Cooling Water 7 C / C Liquid temp. : 40 C Cooling Evaporator water : 7 C / C Water condenser : 30 C / 35 C Water cooled Heating Evaporator water : 7 C / C Water condenser : 40 C / 45 C fan coils Measuring conditions (at nominal air flow and ESP): COOLING: air temperature entering the unit: 7 C/9 C, water temperature entering the unit 7 C, water temperature leaving the unit C - HEATING: room air temperature 0 C, for -pipe units: water temperature entering 50 C - water flow rate same as for the cooling test, for 4-pipe units: water temperature entering 70 C - water temperature leaving 60 C 40

141 4

142 Notes 4

143 Notes 43

144 Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste. The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V. FSC ECPEN-400_AFR Daikin Europe N.V. participates in the Eurovent Certification programme for Air conditioners (AC), Liquid Chilling Packages (LCP) and Fan coil units (FCU), Check ongoing validity of certificate online: or using: VRV products are not within the scope of the Eurovent certification programme. Daikin products are distributed by: Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium BE RPR Oostende ECPEN-400_AFR CD 03 / Copyright Daikin The present publication supersedes ECPEN Printed on non-chlorinated paper. Prepared by La Movida, Belgium Resp. Ed.: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende

Applied systems. Catalogue. Climate comfort. All Seasons. Heating. Air Conditioning. Applied Systems. Refrigeration

Applied systems. Catalogue. Climate comfort. All Seasons. Heating. Air Conditioning. Applied Systems. Refrigeration Applied systems All Seasons Climate comfort Catalogue Heating Air Conditioning Applied Systems Refrigeration No matter how large your premises and whatever your air conditioning needs, there is a Daikin

More information

CHILLERS. Condenserless Chiller 242 EWLP-KAW1N 242 EWLD-MBYN 243 EWLD-DJYNN 244 EWLD-EJYNN 245. Centrifugal Chiller 246 DWSC, DWDC 246

CHILLERS. Condenserless Chiller 242 EWLP-KAW1N 242 EWLD-MBYN 243 EWLD-DJYNN 244 EWLD-EJYNN 245. Centrifugal Chiller 246 DWSC, DWDC 246 No matter how large your premises and whatever your air conditioning needs, there is a Daikin chilled water system to suit your requirements. It is a system that has proved its worth in a multiplicity

More information

Industrial. Catalogue. Climate comfort. All Seasons. Heating. Air Conditioning. Applied Systems. Refrigeration

Industrial. Catalogue. Climate comfort. All Seasons. Heating. Air Conditioning. Applied Systems. Refrigeration Industrial All Seasons Climate comfort Catalogue Heating Air Conditioning Applied Systems Refrigeration No matter how large your premises and whatever your air conditioning needs, there is a Daikin chilled

More information

Industrial. Catalogue. Climate comfort. All Seasons. Heating. Air Conditioning. Applied Systems. Refrigeration

Industrial. Catalogue. Climate comfort. All Seasons. Heating. Air Conditioning. Applied Systems. Refrigeration Industrial All Seasons Climate comfort Catalogue Heating Air Conditioning Applied Systems Refrigeration No matter how large your premises and whatever your air conditioning needs, there is a Daikin chilled

More information

APPLIED SYSTEMS. Water cooled centrifugal chillers 307 EWWD-FZXS 307 DWSC / DWDC 308 DWME 310

APPLIED SYSTEMS. Water cooled centrifugal chillers 307 EWWD-FZXS 307 DWSC / DWDC 308 DWME 310 APPLIED SYSTEMS NEW NEW NEW NEW CHILLERS 240 Products overview - air cooled units 240 Products overview - water cooled and condenserless units 242 Air cooled chillers (Cooling only) 244 EWAQ-ADVP/ACV3/ACW1

More information

GREAT IN COOLING AND HEATING

GREAT IN COOLING AND HEATING GREAT IN CHILLER COOLING AND HEATING APPLIED SYSTEMS CATALOGUE www.daikin.eu 02 Great in cooling and heating TABLE OF CONTENTS PRODUCT PORTFOLIO 04 03 OPTIONS PORTFOLIO 08 ACCESSORIES PORTFOLIO 10 ENVIRONMENAL

More information

Industrial yet. ersonal. Applied systems catalogue

Industrial yet. ersonal. Applied systems catalogue Industrial yet ersonal Applied systems catalogue Table of Contents About Daikin 04 Product portfolio - air cooled 06 Product portfolio - water cooled 08 Inverter technology 10 Seasonal efficiency 12 Reliable

More information

water-cooled CHILLERS

water-cooled CHILLERS water-cooled CHILLERS and condenserless chillers APPLIED SYSTEMS www.daikin.eu Cooling Only Heating Only EWWD170-600DJYNN EWWD190-650DJYNN/A EWLD160-550DJYNN - ABOUT DAIKIN Daikin has a worldwide reputation

More information

Prices and technical information for Applied Systems. Pricelist Applied Systems

Prices and technical information for Applied Systems. Pricelist Applied Systems Prices and technical information for Applied Systems Pricelist 2018-2019 Applied Systems NEW NEW NEW NEW NEW NEW NEW NEW NEW NEW Table of contents Type Refrigerant Compressor Material Capacity Page Key

More information

WATER-COOLED CHILLERS and condenserless chillers

WATER-COOLED CHILLERS and condenserless chillers WATER-COOLED CHILLERS and condenserless chillers APPLIED SYSTEMS www.daikin.eu Cooling Only Heating Only EWWD340-C18EJYNN EWWD360-C12EJYNN/A EWLD320-C17EJYNN - ABOUT DAIKIN Daikin has a worldwide reputation

More information

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X EPCE00-10B Powerful air cooled Hydronic systems EUWA*40-200K(A)X Development Environment Technology 2 Daikin s pre-eminent position in air conditioning and chiller production has been built on over 70

More information

water-cooled CHILLERS

water-cooled CHILLERS water-cooled CHILLERS APPLIED SYSTEMS www.daikin.eu cooling only heating only ABOUT DAIKIN Daikin has a worldwide reputation based on over 80 years experience in the successful manufacture of high quality

More information

air-cooled CHILLERS APPLIED SYSTEMS EWAD AJYNN EWAD AJYNN/A EWAD AJYNN/Q EWAD AJYNN/H

air-cooled CHILLERS APPLIED SYSTEMS  EWAD AJYNN EWAD AJYNN/A EWAD AJYNN/Q EWAD AJYNN/H air-cooled CHILLERS APPLIED SYSTEMS www.daikin.eu EWAD190-600AJYNN EWAD60-650AJYNN/A EWAD10-500AJYNN/Q EWAD00-600AJYNN/H Cooling Only ABOUT DAIKIN Daikin has a worldwide reputation based on over 80 years

More information

air-cooled EWAD-AJYNN(A-Q-H) cooling only

air-cooled EWAD-AJYNN(A-Q-H) cooling only air-cooled CHILLERS APPLIED SYSTEMS www.daikin.eu cooling only ABOUT DAIKIN Daikin has a worldwide reputation based on over 80 years experience in the successful manufacture of high quality air conditioning

More information

Fan coil units EPCE04-25A

Fan coil units EPCE04-25A Fan coil units EPCE04-25A Product portfolio 2 Fan Coil FWV FWL FWM Reference 2-pipe 0 1 2 3 4 5 6 7 8 9 10 11 kw 4-pipe 2 4 6 8 10 12 14 16 18 20 22 24kW FWD 2-pipe 4-pipe Cooling Heating Pictogrammes

More information

air-cooled CHILLERS APPLIED SYSTEMS EWAP-AJYNN(A)

air-cooled CHILLERS APPLIED SYSTEMS EWAP-AJYNN(A) air-cooled CHILLERS APPLIED SYSTEMS www.daikin.eu cooling only ABOUT DAIKIN Daikin has a worldwide reputation based on over 80 years experience in the successful manufacture of high quality air conditioning

More information

Water-cooled chillers Remote condenser chillers NEW

Water-cooled chillers Remote condenser chillers NEW Water-cooled chillers Remote condenser chillers NEW EWWD120-540MBYN EWLD120-540MBYN Applied systems Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants

More information

EWWD MBYN EWLD MBYN Applied systems

EWWD MBYN EWLD MBYN Applied systems Water-cooled chillers Remote condenser chillers EWWD120-540MBYN EWLD120-540MBYN Applied systems Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has

More information

EEDEN technical data. Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT

EEDEN technical data. Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT EEDEN08-424 technical data Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT EEDEN08-424 technical data Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT Fan coil units 1 Hydronic Systems Fan coil units 1 F

More information

Product portfolio. Chillers and air side equipment

Product portfolio. Chillers and air side equipment Product portfolio Chillers and air side equipment Air cooled chillers and condensing units Compressor Water heat exchanger Efficiency version Sound version Refrigerant type * Refrigerant circuits Inverter

More information

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps Chillers Air cooled multi-scroll chillers and heat pumps High efficiency values both in cooling and heating mode Extremely wide operating range, outside ambient temperatures up to 52 C One or two refrigerant

More information

Product portfolio. Chillers and air side equipment

Product portfolio. Chillers and air side equipment Product portfolio Chillers and air side equipment Air cooled chillers and condensing units Compressor Water heat exchanger Efficiency version Sound version Refrigerant type * Refrigerant circuits Inverter

More information

Chillers. Technical Data. EWYD-BZ 250~580 kw

Chillers. Technical Data. EWYD-BZ 250~580 kw Chillers Technical Data A i r C o o l e d C h i l l e r w w w. d a i k i n. e u EWYD-BZ 250~580 kw Daikin Europe N.V. About Daikin Daikin has a worldwide reputation based on over 80 years experience in

More information

EWAD-TZ. Air cooled chiller with R-134a inverter driven screw compressor

EWAD-TZ. Air cooled chiller with R-134a inverter driven screw compressor Air cooled chiller with R-134a inverter driven screw compressor New inverter compressor technology Today, Daikin is leading the way towards more efficient and cost-effective comfort solutions. All Daikin

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

Neosys Product catalogue

Neosys Product catalogue 00/0 Neosys Product catalogue Providing indoor climate comfort NEOSYS 00 0 kw Air cooled chiller/heat pump YEAR WARRANTY* Quality makes the difference* Introduction to the range NEOSYS is providing chilled

More information

Commercial and Technical Data

Commercial and Technical Data Chillers Commercial and Technical Data Air Cooled Single Circuit Condensing Unit» Wide capacity range (120 kw - 490 kw)» One refrigerant circuit with single screw compressor» Two sound versions available»

More information

EPLE Water-cooled chillers Remote condenser chillers. EUW40-200MAXY EUWL40-200MXY Applied systems

EPLE Water-cooled chillers Remote condenser chillers. EUW40-200MAXY EUWL40-200MXY Applied systems EPLE04-24 Water-cooled chillers Remote condenser chillers EUW40-200MAXY EUWL40-200MXY Applied systems Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants

More information

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a Air-Cooled Variable Speed Drive Screw Chillers Super Efficient Super Quiet Cooling Capacity Range 540-1405 kw R134a World s first low sound Air-Cooled variable speed drive screw chiller The recognition

More information

Product portfolio Chillers and air side equipment

Product portfolio Chillers and air side equipment Product portfolio Chillers and air side equipment Daikin Chillers Whatever your needs in climate control or process chilling, there is a system that has proved its value in many situations from factories

More information

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:

More information

EWAT-B. Multi scroll chiller with R-32 refrigerant. First air cooled chiller with environmental friendly R-32 refrigerant

EWAT-B. Multi scroll chiller with R-32 refrigerant. First air cooled chiller with environmental friendly R-32 refrigerant EWAT-B Multi scroll chiller with R-32 refrigerant First air cooled chiller with environmental friendly R-32 refrigerant Daikin, world s first company introducing a new generation of air cooled scroll chiller

More information

Air-cooled chillers with single-screw compressor. Installation, operation and maintenance manual D - KIMAC EN. Original Instructions

Air-cooled chillers with single-screw compressor. Installation, operation and maintenance manual D - KIMAC EN. Original Instructions Installation, operation and maintenance manual D - KIMAC00611-09EN Air-cooled chillers with single-screw compressor EWAD650-C17 C-SS EWAD650-C17 C-SL EWAD620-C16 C-SR EWAD760-C19 C-XS EWAD760-C19 C-XL

More information

EWAD-TZB. Screw inverter chiller. High efficiency chiller for comfort and process cooling

EWAD-TZB. Screw inverter chiller. High efficiency chiller for comfort and process cooling EWAD-TZB Screw inverter chiller High efficiency chiller for comfort and process cooling Why choose Daikin? Daikin were the among first to pioneer the use of inverters in air cooled screw chillers. And

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES COOLING CAPACITY FROM 76 TO 612 Kw 1 AND 2 COOLING CIRCUITS RAE 1702 F Kc + P2 28 Above picture is only indicative

More information

Modular Air-cooled Chillers

Modular Air-cooled Chillers Modular Air-cooled Chillers High Seasonal Efficiency (HSE) version Cooling capacity 48-232 kw Trane Flex Series Modular air/water chillers with axial EC fans, inverter driven scroll compressors and microchannel

More information

Applied Systems. Technical Data. Air cooled chiller, standard efficiency, standard sound EEDEN EWAD-D-SS

Applied Systems. Technical Data. Air cooled chiller, standard efficiency, standard sound EEDEN EWAD-D-SS Applied Systems Technical Data Air cooled chiller, standard efficiency, standard sound EEDEN-44 EWAD-D-SS TABLE OF CONTENTS EWAD-D-SS Features.............................................................

More information

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 46 Above picture is only indicative and is not binding AIR FC The packaged air cooled chillers of RAS Kp series are suitable

More information

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw AIR-COOLED LIQUID CHILLER REVERSIBLE AIR-TO-WATER HEAT PUMP PRO-DIALOG PLUS 30RB/RQ 039S-60S Refrigerant HFC-40A Nominal cooling capacity 40-58 kw Nominal heating capacity 4-59 kw The new generation of

More information

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series Type of Compressors Compressor Rotary Scroll Reciprocating Screw Centrifugal Air Cooled Chiller 77 ~ 329TR (270 ~ 1156 kw) ACDX Series 100 ~ 520TR

More information

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C Air Conditioning Technical Data Pair, Twin, triple, double twin EEDEN-00 RZQ-C TABLE OF CONTENTS RZQ-C Features............................................................. 2 2 Specifications.......................................................

More information

Chillers. Technical Data. Air Cooled Chiller ECDEN10-403A EUWA*-KBZW1 EUWY*-KBZW1

Chillers. Technical Data. Air Cooled Chiller ECDEN10-403A EUWA*-KBZW1 EUWY*-KBZW1 Chillers Technical Data Air Cooled Chiller ECDEN0-403A EUWA*-KBZW EUWY*-KBZW Chillers Technical Data Air Cooled Chiller ECDEN0-403A EUWA*-KBZW EUWY*-KBZW Single Unit Air cooled chiller EUWA-KBZW TABLE

More information

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the

More information

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS Energy saving thanks to a total recovery p Cooling Heating/DHW h Galletti multi-purpose heat pumps are total recovery units used for a simultaneous hot and

More information

FWV 04 FWL 05 FWM 06 FWB 07 FWD 08. Control 09. Accessories 10. Daikin Europe N.V.

FWV 04 FWL 05 FWM 06 FWB 07 FWD 08. Control 09. Accessories 10. Daikin Europe N.V. Daikin has a worldwide reputation based on over 80 years experience in the successful manufacture of high quality air conditioning equipment for industrial, commercial and residential use. Daikin Europe

More information

Application guide NEOSYS kw. Air cooled liquid chiller Heat pump NEOSYS-AGU-0610-E

Application guide NEOSYS kw. Air cooled liquid chiller Heat pump NEOSYS-AGU-0610-E Application guide NEOSYS 200-1000 kw NAC NAH Air cooled liquid chiller Heat pump NEOSYS-AGU-0610-E TABLE OF CONTENTS APPLICATION GUIDE Ref : NEOSYS-AGU-0610-E 1. GENERAL Model number description Key customer

More information

Galletti Water chillers and heat pumps catalogue

Galletti   Water chillers and heat pumps catalogue Galletti www.galletti.it Water chillers and heat pumps catalogue Table of Contents/SMALL SYSTEMS MPI DC Water chillers and heat pumps with inverter compressor 6 models page 6 MCE MPE Air condensed water

More information

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Quality Management Systems 0RB 008-05 Nominal cooling capacity 8- The new generation of Aquasnap liquid chillers was designed

More information

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel Daikin Applied UK Technically better... D-AHU Modular R Air handling units Compact air handling unit with heat recovery wheel Energy efficiency and air quality With their Plug & Play design and inherent

More information

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata EKS/HE Refrigerant R410A GWP=2.088 Scroll Compressor Shell & Tube exchanger Axial fan Brazed plate heat exchanger MultiScroll Air-cooled liquid chillers High efficiency Solution B - Base I - Integrata

More information

Optimised for high ambient operation (up to 55 C ambient) EWAD-MZ. Air cooled chiller

Optimised for high ambient operation (up to 55 C ambient) EWAD-MZ. Air cooled chiller Optimised for high ambient operation (up to 55 C ambient) EWAD-MZ Air cooled chiller Why choose Daikin? Daikin were the among first to pioneer the use of inverters in air cooled screw chillers. And today,

More information

Chiller Manufacturer should have been manufacturing chillers utilizing magnetic bearing, oil free technology for more than 10 years.

Chiller Manufacturer should have been manufacturing chillers utilizing magnetic bearing, oil free technology for more than 10 years. TURBOCOR COMPRESOR CHILLERS General Description Microprocessor controlled, water chiller using HFC 134a refrigerant, two stage centrifugal oil free variable speed compressor's and electronic expansion

More information

PRODUCT GUIDE

PRODUCT GUIDE PRODUCT GUIDE 01.2017 Cooling Heating CHAPTER 1 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Power (kw) Page IACAK/II/WP 101.5 106 0 58 115 A CLASS energy efficiency

More information

Water cooled screw chillers

Water cooled screw chillers 0 Product Manual 808 B 08/01 A Date: January 2008 Supersedes: 807 B 04/11 C Water cooled screw chillers PROXIMUS EVOLUTION SE (Standard Efficiency) 111.1 596.2 Cooling capacity from 388 a 2093 kw XE (High

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are

More information

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: 40-158 kw Nominal heating capacity: 41-159 kw Carrier China Carrier Corporation is a subsidiary of the United Technologies

More information

NEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com

NEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com NEOSYS AIR TO WATER LIQUID CHILLER 200-1000 kw AIR TO WATER HEAT PUMP 200-500 kw lennoxemea.com NEOSYS, winning ENERGY PERFORMANCE The NEOSYS delivers energy efficiency at full and partial load by the

More information

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1 UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A

More information

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB Packaged air cooled liquid chillers for outdoor installation 42 574 kw technicalcatalogue T_EGL_1012_GB INDEX EUROVENT CERTIFICATION... 3 GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION...

More information

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01 b cool manufacturers of air-conditioning equipment ltd BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION Ver. 1.01 Ver. 3.02 01_18 BCool# 1 brt c/h r407c / r410a

More information

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS Total heat recovery multi-purpose units LCP Outdoor monobloc air-water unit LCP - kw Heating, cooling, domestic hot water one single system to meet all kinds of needs. Total heat recovery multi-purpose

More information

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01

More information

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1 Heating Technical Data Daikin Altherma low temperature monobloc EEDEN3-725 EBLQ-BB6W Monobloc with bottom plate heater EBLQ-BB6W TABLE OF CONTENTS EBLQ-BB6W Features.............................................................

More information

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

INVERTER SCROLL. LG Electronics     Distributed by. Copyright 2017 LG Electronics. All rights reserved. LG Electronics http://www.lg.com http://partner.lge.com Distributed by Copyright 2017 LG Electronics. All rights reserved. FEATURES & BENEFITS High Efficient Inverter Technologies EER 2.65 / COP 3.2 /

More information

pyxis u pyxis ua NEW rcgroupairconditioning

pyxis u pyxis ua NEW rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44,9 200,0 rcgroupairconditioning R410 C PLTE

More information

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient PRODUCT SELECTION DATA Easy and fast installation Compact, reliable and efficient Class A variable speed circulator available Air-Cooled Liquid Chillers 0RB 008-015 CARRIER participates in the ECP programme

More information

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw PROCESS CHILLERS AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com PROCESS CHILLERS MAXIMUM EFFICIENCY IN EVERY TYPE OF PROCESS APPLICATION Air cooled liquid chiller for outdoor

More information

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3 Heating Technical Data Daikin Altherma low temperature monobloc EEDEN3-725 EDHQ-BB6V3 Monobloc without bottom plate heater EDHQ-BB6V3 TABLE OF CONTENTS EDHQ-BB6V3 Features.............................................................

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are

More information

Databook. Air cooled screw chillers EWAD~C- Performance according to EN Code: CSS - Rev. 9.0 Printing date: 5/16/2014

Databook. Air cooled screw chillers EWAD~C- Performance according to EN Code: CSS - Rev. 9.0 Printing date: 5/16/2014 Code: CSS - Rev. 9.0 Printing date: 5/16/2014 Databook EWAD~C- R3.6.2 Air cooled screw chillers EWAD~C- C-SS (Standard Efficiency - Standard Noise) - Cooling Capacity from 647 to 1922 kw Performance according

More information

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics     Distributed by 4mm 이상 ~ 15mm 미만 (음화형 규정) LG Electronics http://www.lg.com http://partner.lge.com Copyright 2017 LG Electronics. All rights reserved. Distributed by FEATURES & BENEFITS High Efficient Inverter Technologies

More information

Water-cooled chillers with High Speed Centrifugal Compressors

Water-cooled chillers with High Speed Centrifugal Compressors Water-cooled chillers with High Speed Centrifugal Compressors Refrigerant R134a 190-760 (395 to 2660 kw) Refrigerant R1234ze 135 G - 505 G (310 to 1820 kw) Table of Contents Introduction...3 Features and

More information

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning : Packaged air cooled liquid chillers with free-cooling system for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 314 1343 Free-Cooling Capacity: 308 938 GLYCOL

More information

44,9 202,0 kw. technicalcatalogue

44,9 202,0 kw. technicalcatalogue Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressor and microchannel condensing coils 44,9 202,0 kw technicalcatalogue T_PYXU_0413_GB INDEX EUROVENT CERTIFICATION...

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

kw. technicalcatalogue

kw. technicalcatalogue Packaged air cooled liquid chillers in A class energy efficiency for outdoor installation equipped with scroll compressor and microchannel condensing coils 108 876 kw technicalcatalogue T_PYXCLA_0413_GB

More information

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

pyxis hp u pyxis hp u IDEA NEW rcgroupairconditioning Comfort PYXIS HP U : ir / water reversible heat pumps for outdoor installation, equipped with scroll compressors and axial fans Cooling Capacity: 42,3 195,0 Heating Capacity: 47,1 222,0 NEW IDE R410 rcgroupairconditioning

More information

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly. HITACHI proudly presents to our customers this wide range of split system air conditioners, from 4HP to 20 HP which is designed for high and medium outdoor temperature and comply with almost any types

More information

Air Conditioning. Technical Data EEDEN AZQS-BV1

Air Conditioning. Technical Data EEDEN AZQS-BV1 Air Conditioning Technical Data EEDEN14-131 AZQS-BV1 TABLE OF CONTENTS AZQS-BV1 1 Features............................................................. 2 2 Specifications.......................................................

More information

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS R Products That Perform...By People Who Care FORM NO: MS0455A WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS R134a HXWC SERIES 205 to 560 Tons 60Hz INTRODUCTION Dunham-Bush's HXWC water cooled

More information

kw COOLING kw HEATING

kw COOLING kw HEATING Heat pump water/water liquid chillers for indoor installation. Inversion on hydraulic circuit. 394 1505 kw COOLING 477 1976 kw HEATING technicalcatalogue T_FRGSCRWP_0913_GB INDEX GENERAL CHARACTERISTICS...

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

HYDROCIAT LW R407C. Water cooled chillers USE RANGE Screw compressors CIAT dry direct expansion shell and tubes evaporator HPS equipment (High Power System) cooling or heating Heat recovery ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT

More information

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS RAE 1352 F.K + MV AIR R-407C FC Series RAE... F.K Cooling capacity from 77 to 289 kw - 2 circuits The air cooled chillers of RAE... F.K series, are designed for outdoor installation and are particularly

More information

Leadership, Innovation, Advanced Technology Synergise Here!

Leadership, Innovation, Advanced Technology Synergise Here! Cooling Synergies Leadership, Innovation, Advanced Technology Synergise Here! 125 years of Engineering Innovation Kirloskar Chillers is proud to be a part of 125 years old Kirloskar Group. The diversified

More information

pyxis pyxisa NEW rcgroupairconditioning

pyxis pyxisa NEW rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 119,0 808,0 PLTE C rcgroupairconditioning

More information

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw COMFORT CHILLERS AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com COMFORT CHILLERS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air-cooled liquid chiller for outside installation

More information

Innovation for a Better & Greener Future

Innovation for a Better & Greener Future Innovation for a Better & Greener Future Comprehensive range of Water Cooled Variable Speed Centrifugal Chillers with Magnetic Bearing Compressors Kirloskar Chillers, a future-focused organisation, has

More information

kw. technicalcatalogue

kw. technicalcatalogue Packaged air cooled liquid chillers for outdoor installation equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded evaporator and microchannel condensing coils. 280

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

PYXIS U PYXIS U. rcgroupairconditioning

PYXIS U PYXIS U. rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44 284 rcgroupairconditioning MIN FETURES

More information

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1. SECTION 236426 - ROTARY-SCREW WATER CHILLERS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes packaged, water cooled or air cooled as scheduled, electric-motor-driven, rotary-screw water chillers

More information

KELVIN Clim F497. Kelvin air conditioning

KELVIN Clim F497. Kelvin air conditioning KELVIN Clim F497 Cooling Capacity: 400 ~ 1260 kw Free-Cooling Capacity: 497 ~ 1492 kw Packaged air cooled liquid chillers with free-cooling system in A class energy efficiency for outdoor installation,

More information

Blue Box Epsilon Echos +

Blue Box Epsilon Echos + Blue Box Epsilon Echos + 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Packaged version in 5 sizes Nominal cooling capacity (A35;W7): 6 26 kw Nominal heating

More information

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE

More information

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.

More information