1 Table of Contents 1 Callisto 100 Shut-off Valve Set Installation Operating the Shut-off Valve Opening and Closing the Shut-off Valve Callisto 100 Shut-off Valve Set The optional shut-off valve set (mat. no ) is required to shut off the external cooling circuit when the Callisto 100 is switched off and not in use in order to prevent condensation or even ice formation in the inside of the device. NOTICE The shut-off valve set can be used to upgrade existing Callisto 100 devices. If you are upgrading an existing device, please follow all steps in this instruction. As of serial number , all Callisto 100 devices are prepared for the shut-off valve and some parts of the shut-off valve set are already installed by the manufacturer. If you are installing such a device, please unscrew the glass overflow and vacuum equalizing vessels to gain easier access and begin the installation of your Callisto 100 with step 5. The complete shut-off valve set consists of: Mat. no. Description Amount Shut-off valve M16x C Threaded fitting G3/8" to M16x Hose nipple D 9, Union nut M16x O-ring, NBR 70 Shore A Insulating board for external cooling device connection Insulating tube for shut-off valve Insulating tape 1 m Hose clip 2 Created by Pütz, Dunja on H26IE008EN-B_ProdInfo_Callisto100_ShutOffValve.docx page 1 of 6
2 2 Installation To install the shut-off valve, follow these steps: 1. Unscrew the glass overflow and vacuum equalizing vessels to gain easier access. Then unscrew the hose connections from the back of the Callisto 100 device. Fig. 1 Unscrewing the hose connections Fig. 2 Removed hose connections 2. Put the O-rings on the threaded fittings. Fig. 3- Threaded fittings and O-rings Fig. 4 Assembled fittings 3. Screw the threaded fittings into the cooling circuit connections at the back of the Callisto Created by Pütz, Dunja on H26IE008EN-B_ProdInfo_Callisto100_ShutOffValve.docx page 2 of 6
3 Fig. 5 Mounting the threaded fittings Fig. 6 Screwed-in fittings 4. Put the insulating board into the recess around the fittings. Insulating board Fig. 7 Inserted insulating board 5. Place the union nuts over the hose nipples. Fig. 8- Hose nipples and union nuts Fig. 9 Assembled hose nipples 6. Mount the shut-off valve onto the threaded fitting marked with IN. Created by Pütz, Dunja on H26IE008EN-B_ProdInfo_Callisto100_ShutOffValve.docx page 3 of 6
4 Fig. 10 Shut-off valve Fig. 11 IN threaded fitting 7. Screw the hose nipples on to the shut-off valve and the threaded fitting marked with OUT. Installed hose nipples Fig. 12 Mounted shut-off valve and hose nipples NOTICE The shut-off valve must be installed at a slight angle otherwise its movement would be obstructed by the glass vessels. Before continuing the installation, re-install the glass overflow and vacuum equalizing vessels and check whether the leaver of the shut-off valve can be moved freely without obstruction. 8. Before connecting the hoses for the cooling circuit, slide the insulating tube for the shut-off valve over the hoses. 9. Connect the cooling circuit hoses to the hose nipples and secure the connections with the hose clips. Insulating tube for the shut-off valve Fig. 13 Connecting and securing the cooling circuit hoses Created by Pütz, Dunja on H26IE008EN-B_ProdInfo_Callisto100_ShutOffValve.docx page 4 of 6
5 10. Slide the insulating tube over the shut-off valve right up to the Callisto 100 housing. Then slide the insulating tubes of the cooling hoses right up to the insulating tube for the shut-off valve. Fig. 14 Insulating tube Fig. 15 Insulating the cooling hoses 11. Cover all joints of the insulating tubes with the adhesive insulating tape and re-install the glass vessels which you removed in step 1. Fig. 16 Insulating all joints Created by Pütz, Dunja on H26IE008EN-B_ProdInfo_Callisto100_ShutOffValve.docx page 5 of 6
6 3 Operating the Shut-off Valve All Callisto 100 instruments connected to the external cooling system must always be switched on when the cooling system is up and running to prevent possible damage to the Callisto 100 instruments. In order to avoid having to switch on devices you might not need for testing, you can also use the optional shut-off valve between the Callisto 100 and the external cooling device. Important When you switch off the Callisto 100 device, you must either also switch off the external cooling system or close the shut-off valve at the Callisto 100 to close the cooling liquid circuit to your device. When you switch the Callisto 100 device on again, you must also open the valve to the cooling system. 3.1 Opening and Closing the Shut-off Valve The shut-off valve is mounted at the back of the Callisto 100 device. Simply turn the leaver to open or close the connection to the cooling circuit. Fig Shut-off valve in open position Fig. 18 Shut-off valve in closed position Contact us at Anton Paar ProveTec GmbH Ludwig-Erhard-Ring Blankenfelde-Mahlow Germany Phone: +49 (0) Fax: +49 (0) info.provetec@anton-paar.com Website: Created by Pütz, Dunja on H26IE008EN-B_ProdInfo_Callisto100_ShutOffValve.docx page 6 of 6
in-bench PITCHER rinser installation intructions
Preparing Bench for Installing Main Body Remove rinser from packaging and measure the physical unit prior to cutting bench (see image #1) Measure to the external edge of the mounting tabs. Leave 3mm gap
More informationNut & Bolt Faucet Installation
Nut & Bolt Faucet Installation Nut & Bolt Faucet Installation STEP 1 Layout all faucet components that will be installed. STEP 2 Turn faucet head to expose water supply attachment plugs holes. Attach water
More informationSpare parts list ( ) Spare parts list Priza
Spare parts list (5.970-755.0) Spare parts list Priza 2011-06-17 www.kaercher.com EN Page 2 Page 3 Page 4 Table of contents Spare parts list Priza (5.970-755.0)... 6 10 Tank water (0.164-654.0)... 7 20
More informationSpare parts list ( ) Spare parts list PUZZI 100 *USA
Spare parts list (5.958-246.0) Spare parts list PUZZI 100 *USA 14.12.2012 www.kaercher.com EN Page 2 Page 3 Page 4 Table of contents Spare parts list PUZZI 100 *USA (5.958-246.0)... 6 10 Tank water (0.162-794.0)...
More informationFlow switch. Operating Manual. English manual page Page 1 of 15 Fax:
Operating Manual www.jlso-tec-trade.de Flow switch English manual page 1-15 Page 1 of 15 Flow switch Table of Contents Page 1 Device Description and Intended Use... 19 1.1 Flow switch version VH...X...
More informationSpare parts list ( ) Spare parts list PUZZI 100
Spare parts list (5.958-029.0) Spare parts list PUZZI 100 10.02.2012 www.kaercher.com EN Table of contents Spare parts list PUZZI 100 (5.958-029.0)... 6 10 Tank water PUZZI 100 (0.162-640.0)... 7 20 Appliance
More informationBoiling water heater HBE
Application areas Boiling water supply: > Offices > Canteens / Bistros > Restaurants / Hotels > Hospitals Product information 1 / 6 Product information boiling > 6-003 6-005 6-007 Part number [case painted
More informationChemical resistant Vacuum Pumps
Chemical resistant Vacuum Pumps C300 / C400 / C410 / C510 / C600 / C610 English Operating Manual WIGGENS labortechnik GmbH Mühsamstrasse 3610249 Berlin Germany Fon:+49 30 42105470 Fax:+49 30 42105971 E-Mail:
More informationFSW300 Series Flow Switch
. FSW300 Series Flow Switch - 2 - Series FSW300 Series FSW300 Table of contents page 0 About this operating manual... 4 1 Device description... 5 1.1 Intended use... 5 1.1.1 Reed contact - Switching of
More informationKITCHEN FAUCET COS-KF222C
KITCHEN FAUCET COS-KF222C USER S MANUAL & INSTALLATION GUIDE Thank You Thank you for your purchase. We know that you have many brands and products to choose from and we are honored to know that you have
More informationProblem-solvers The Radiator Solution Range
Simplex Problem-solvers Problem-solvers The Radiator Solution Range I Height and depth compensation I Continuously swivelling connections I Reversal of supply and return flow I Quick and clean radiator
More informationSettlement Agreement. Schedule 1: Covered Products
Settlement Agreement Schedule 1: Covered Products COVERED PRODUCT BRANDS BRASSCRAFT PLUMBSHOP PEERLESS SOLUTIONS MASTER PLUMBER COVERED PRODUCT CATEGORIES - WATER SUPPLIES SUPPLY STOPS WATER SUPPLY CONNECTORS
More informationTOYOTA FJ-40 DIRECTIONS
PAGE 1 TOYOTA FJ-40 DIRECTIONS Please read the following directions prior to installing this a/c system. Contact us by email or phone if you need any assistance or information regarding this a/c system.
More informationInstallation Instructions
PAGE 1 Installation Instructions Important information about your new a/c system. Please read the following directions prior to installing this a/c system. PN: CK6772-1CHPU 1967-1972 Chevy PU A/C Kit Contact
More informationInstall Guide MXS-BRO SERIES SMALL BRO LED MULTIPLE RECESSED
MXS-BRO SERIES SMALL MULTIPLE RECESSED This product must be installed in accordance with the applicable code by a person familiar with the construction and operation of the product and the hazards involved.
More informationInstruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System
Effective: 5/13/15 Supersedes: New IS-AM09-601 Instruction Sheet Point of Use Hot Water Recirculation System THANK YOU for purchasing a new Aquamotion Hot System! For optimum reliability and performance
More informationSeries 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING
Series 47 and 247 Mechanical Water Feeders McDonnell & Miller Installation & Maintenance Instructions MM-316(C) Series 47-2 and 247-2 Combination Mechanical Water Feeder/Low Water Cut-Off Series 47 Water
More informationBoiling water heater KA
Application areas Boiling water supply: > Offices > Canteens / Bistros > Restaurants / Hotels > Hospitals > Catering services Product information 1 / 7 Product information boiling > 15 25 40 Part number
More informationWogaard Coolant Saver TM
Wogaard Coolant Saver TM Version 1.5-US Preface Thank you for purchasing the Wogaard Coolant Saver TM. This unit is designed and optimized specifically for use with machine tools. It employs Wogaard s
More informationOil burners fuel unit with solenoid valve
Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Germany VM_e.pdf - 18.05.08 Page 1/6 Oil burners fuel unit with solenoid valve
More informationHVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS
230500 HVAC BASIC MATERIAL AND METHODS PART 1 GENERAL 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS A. Section 230000 Basic HVAC Requirements B. Section 230523 Valves C. Section 230510 Chilled
More information51AKB / 51 AKC OWNER S MANUAL
51AKB / 51 AKC OWNER S MANUAL This manual applies to the following models 51AKB 009 51AKB 012 51AKC 009 51AKC 012 Read this instruction manual thoroughly before using the air conditioner. Control panel
More informationSAMSON LIQUID RING VACUUM PUMPS VACUUM LIMITER INSTRUCTION MANUAL FOR VACUUM LIMITER ATEX APPROVED DOC4000E
TRUCKS FOOD SAMSON LIQUID RING VACUUM PUMPS INSTRUCTION MANUAL FOR VACUUM LIMITER ATEX APPROVED DOC4000E OFFSHORE FISH INDUSTRY VACUUM LIMITER 2 CONTENTS 1 Introduction... 4 1.1 Declaration of incorporation...4
More informationInstallation Instructions
Installation Instructions SELECTRONIC Thermostatic Mixing Valve 0XTMV070 Certified to comply with ASME A.8.M 0 American Standard M97 Specifications Installation Adjust Temperature Service Replacement Parts
More informationSERVICE MANUAL FOR MODEL RM-10
SERVICE MANUAL FOR MODEL RM-10 REQUIRED TOOLS CORDLESS DRILL COPPER CUTTING TUBE 1/2 OPEN WRENCH SOLDERING IRON SCREWDRIVER SET WITH 9/32 SOCKET VISE GRIP PIERCING VALVE PRECISION FLAT BLADE SLOTTED SCREWDRIVER
More informationTREVI BLEND SINGLE LEVER SHOWER VALVES. INSTALLER After installation pass to user for future reference
11 A4000, A4100 & A4110 TREVI BLEND PARTS LIST Ref. Description 1 Lever handle complete 1a/1b Nut and washer 2 Handle cover cap 3 Shield 4 Cover plate fixing screw 5.1 Cover plate for built in version
More informationHandshower, Hose & Handshower Accessories
P24443, P24445, P24446, P24452, P24453, P24456 1 of 6 INSTALLATION INSTRUCTIONS Thank You For Choosing KALLISTA We appreciate your commitment to KALLISTA quality products. Please take a moment to review
More informationCondensate Monitor CGKW. Operator s Manual 42/23-36 EN Rev. 2
Condensate Monitor CGKW Operator s Manual 42/23-36 EN Rev. 2 Parts Supplied with the Unit Qty. Description 1 Mounting bracket 2 Nozzles G1/4 2 O-rings for nozzles 25 Filter membranes (of glass fibre) Examples
More informationAUTOMATIC GRANULAR ICE FLAKER
AUTOMATIC GRANULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24480 rev. 01 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on choosing a
More informationDimensions: 39 1/2" w x 22" D x 35.5 H. kk25 installation. Things you might need for the installation: vessel sink,
Things you might need for the installation: vessel sink, plumber's putty(home depot), liquid nails(home depot), Bucket silicone caulk(home depot), Putty knife Plumber's putty Pipe wrench Channel-lock pliers
More informationPlease do not hesitate to contact us with any enquiries.
PRIMARILY DESIGNED TO BE FITTED INTO ANY CARAVAN WITH AN ONBOARD WATER PUMP SUCH AS THE WHALE, SHURFLO OR FIAMMA PUMPS, WHICH MOST CARAVAN MANUFACTURERS FIT AS STANDARD. IDEAL FOR WINTER CARAVANING. THE
More informationThermostatic valves with radiator connection systems
Multilux Eclipse Thermostatic valves with radiator connection systems with two-point connection for two-pipe heating systems, with automatic flow limitation IMI HEIMEIER / Thermostatic heads and Radiator
More informationInstallation instructions Air drying unit for Bubble Sensor OTT CBS. English
Installation instructions Air drying unit for Bubble Sensor OTT CBS English 1 Scope of supply Air drying unit 1 air drying unit with 400 gram drying medium, air humidity indicator and mounting bracket
More informationSERVICE MANUAL FOR MODEL RM-26
SERVICE MANUAL FOR MODEL RM-26 REQUIRED TOOLS CORDLESS DRILL DRIVE CUTTING TUBING OPEN WRENCH OF 1/2 RATCHET WITH SOCKET OF 7/16 SCREWDRIVER SET WITH SOCKET OF 9/32 VISE GRIP PIERCING VALVE WATCHER SLOTTED
More informationInstallation Instructions
Installation Instructions SELECTRONIC Thermostatic Mixing Valve 605XTMV Certified to comply with ASME A.8.M 005 American Standard M968808 Specifications Installation Adjust Temperature Service Replacement
More informationSERVICE MANUAL FOR MODEL RM-49
SERVICE MANUAL FOR MODEL RM-49 REQUIRED TOOLS CORDLESS DRILL DRIVE CUTTING TUBING OPEN WRENCH OF 1/2 RATCHET WITH SOCKET OF 7/16 SCREWDRIVER SET WITH SOCKET OF 9/32 VISE GRIP PIERCING VALVE WATCHER SLOTTED
More informationGrohtherm Grohtherm 1000
34 154 Grohtherm 1000 Grohtherm 1000 GB D...1 I...5 N...9 GR...13 TR...17 BG...21 RO...25 GB...2 NL...6 FIN...10 CZ...14 SK...18 EST...22 CN...26 F...3 S...7 PL...11 H...15 SLO...19 LV...23 RUS...27 E...4
More informationINSTRUCTION MANUAL. Nunc-Immuno Wash. 8, 12 and 16 channel washer
INSTRUCTION MANUAL Nunc-Immuno Wash 8, 12 and 16 channel washer Nunc-Immuno Wash 8, 12, 16 channel washer We thank you for having bought this Nunc-Immuno Wash. In order to gain full benefit of the washer
More informationGeneral System Layout Sketch
General System Layout Sketch EZ-37 Solar Panels PV panel Glycol Fill Valve Expansion Tank ` 1 Introduction This document describes how to install a Heliatos GH type solar water heating system. These systems
More information215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions
215 Gallon Waste Oil Tank With Bypass Regulator Installation Instructions Lanair Products LLC 4109 Capital Circle Janesville, Wisconsin 53546 1-888-370-6531 www.lanair.com BEFORE YOU BEGIN INSTALLATION...
More informationPD10. Serial Plates with Side Ports for ISO Valves. Technical Features. Technical Data. Functional Description. Page 1. Size 10 (D05) p max
Serial Plates with Side Ports for ISO 4401-05 Valves PD10 Size 10 (D05) p max 250 bar (3600 PSI) Technical Features ISO 4401-05-04-0-05 46(1.81) ed to connect in parallel two or more ISO 4401-05 (CETOP
More informationJoto Automatic Mug Press Manual Model No.: E-HP-JMP-AUTO
Joto Automatic Mug Press Manual Model No.: E-HP-JMP-AUTO OPERATOR S MANUAL TM Bringing images to life TM Safety Instructions 2 Safety 3 4 5 6 7 Maintenance 8 8 9 11 3 3 5 4 7 1 6 4 1.) Turn the Main Power
More informationParts & Material Included
O² Hydro Well System Installation, Use & Care Guide Parts & Material Included 1. Funnel 11. Drain Line 21. Air Head 2. Media Tank Distributer Tube 12. Air Release 22. Drain Fitting 3. Air Tank Distributer
More informationHEATING AND AIR CONDITIONING
PL HEATING AND AIR CONDITIONING 24-1 HEATING AND AIR CONDITIONING TABLE OF CONTENTS page REMOVAL AND INSTALLATION EVAPORATOR CORE R. H. D....1 HEATERCORE R.H.D...3 page SPECIFICATIONS TORQUE SPECIFICATIONS...6
More informationMODULAR AUTOMATIC GRANULAR ICE FLAKER
MODULAR AUTOMATIC GRANULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24479 rev. 03 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on having
More informationInformation is subject to change. Please refer to our website to obtain the most current product specification, technical & warranty information.
Installation instructions Information is subject to change. Please refer to our website to obtain the most current product specification, technical & warranty information. The installation steps are described
More informationJOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)
P. 1 of 12 JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30) Item: Qty: Description: 1 2 1 x 1 x 5/8 Tee Fitting 2 2 Plastic Snap-in Hose Grommet 3 4 1-1/2" Hose Clamps
More informationMishimoto Performance Aluminum Mustang Radiator - Automatic - (97-04 GT/Cobra/MACH1/Bullitt) - Installation Instructions
Mishimoto Performance Aluminum Mustang Radiator - Automatic - (97-04 GT/Cobra/MACH1/Bullitt) - Installation Instructions The below installation instructions work for the following products: Mishimoto Performance
More informationkk21 installation Kk21-WF21 Things you might need for the installation: vessel sink,
Kk21-WF21 Things you might need for the installation: vessel sink, plumber's putty(home depot), liquid nails(home depot), Bucket silicone caulk(home depot), Putty knife Plumber's putty Pipe wrench Channel-lock
More informationGrohtherm 1000 Cosmopolitan. Grohtherm 1000 Cosmopolitan. Design & Quality Engineering GROHE Germany /ÄM /06.12
34 448 Grohtherm 1000 Cosmopolitan GB D...1 I...5...2 N...9...3 GR...13...5 TR...17...6 BG...21...7 RO...25...9 GB...2...1 NL...6...2 FIN...10...4 CZ...14...5 SK...18...6 EST...22...8 RUS CN...26...9 F...3...1
More informationRegulux. Radiator lockshield with drain-off facility. To be precise.
Radiator lockshield with drain-off facility To be precise. Description Assembly Regulux Closing cap Thrust piece HEIMEIER radiator lockshield for shutting off, presetting, draining off and filling. Separate
More informationSPEAKMAN SPEAKMAN SPECIFICATIONS
SE-575-DP-237 & SE-575-DP-238 Installation, Operation, and Maintenance Instructions EYESAVER EYE/FACE WASH & SAFE-T-ZONE EMERGENCY SURFACE MOUNTED WALL SHOWER DESCRIPTION Barrier-Free wall mounted emergency
More informationSHOT BLAST CABINET USER INSTRUCTIONS. Model No: CSB20B. Part No: GC05/13
SHOT BLAST CABINET Model No: CSB20B Part No: 7640110 USER INSTRUCTIONS GC05/13 INTRODUCTION Thank you for purchasing this CLARKE Shot Blast Cabinet which is designed for professional workshop use. Please
More informationHeat Exchanger Block Replacement Instructions
Series 1-4 Gas-fired water boiler Heat Exchanger Block Replacement Instructions Ultra-80 S1-4 Heat Exchanger Block Replacement Kit, Part No. 383-500-773 Ultra-105 S1-4 Heat Exchanger Block Replacement
More informationCable Drain & Cable Drain Trim Kit
INSTALLATION INSTRUCTIONS Cable & Cable Trim Kit P21581 & P21582 1 of 6 INSTALLATION INSTRUCTIONS Cable & Cable Trim Kit THANK YOU FOR CHOOSING KALLISTA We appreciate your commitment to Kallista quality
More informationFLUSH WATER SAVER DUAL FLUSH KIT
FLUSH CH ICE Version 12.26.08 FC002 WATER SAVER DUAL FLUSH KIT Dear Consumer; You have purchased a high quality water saver dual flush toilet valve kit. Every care has been taken during manufacturing to
More informationInstructions CH Chrome SS Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet. Tools Required.
Instructions *Image may vary slightly from actual product Tools Required Adjustable Wrench Groove Joint Pliers Pipe Wrench Phillips Screwdriver Pipe Tape or pipe thread compound Safety Tips If you solder
More informationInstructions. Certifications Chrome 2-handle Chrome 3-handle 10-B83-WCH-AD Chrome 3-handle 10-B82-WCH-AD Chrome 2-handle
Instructions 623282 Chrome 2-handle *Image may vary slightly from actual product Tools Required Adjustable Wrench Groove Joint Pliers Pipe Wrench Phillips Screwdriver Pipe Tape or pipe thread compound
More informationO.D / 2" (444) 15 1 / 2 " (393) Maximum I.D / 4 " (336) 1 3 / 4 " (45) 1 1 / 4 " (32)
standard basin 100 Specifications 1.1.3 Standard Round Basin with Overflow Item No. 100 For Undercounter Mount Installation Recommended openings for Under Counter mounting: Min. Diameter: 13 1 / 4 (337).
More informationBasin Mixer. Installation & Aftercare Instructions. Please retain for future reference.
Basin Mixer Installation & Aftercare Instructions Please retain for future reference. This guide covers the installation of all basin mixer varients. Please select the installation diagram suited to the
More informationWithdrawable module with vacuum circuit-breaker 3AE and installation accessories kv, ka kv, 40 ka 24 kv, ka
SION Withdrawable module with vacuum circuit-breaker 3AE and installation accessories 7.2 17.5 kv, 12.5 31.5 ka 7.2 17.5 kv, 40 ka 24 kv, 16 25 ka OPERATING INSTRUCTIONS Siemens AG 2006. All rights reserved.
More informationInstruction manual. Carlin Combustion Technology, Inc. 70 Maple Street East Longmeadow, MA Ph Fx
Instruction manual Applies to air intake assemblies: 97406 on EZ-1 burners 97406C on EZ-LF burners 97406A or 97406B on EZ-Gas burners Installation also requires a Field Controls Model CAS 1 air hood and
More informationDetermination of the enthalpy of vaporization of liquids
Related concepts Enthalpy of vaporization, enthalpy of condensation, enthalpy of sublimation, vapour pressure, entropy of vaporization, Clapeyron-Clausius equation, Trouton s rule, laws of thermodynamics,
More informationTHERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES
ST.07.05.00 THERMOSTIC SINGLE-PIPE AND DOUBLE-PIPE VALVES 1. Art.1420 THERMOSTIC SINGLE-PIPE VALVE Single-pipe valves allow manual, thermostatic or thermo-electric regulation. Separation of the lockshield
More informationGas expansion thermometer
Gas expansion thermometer Type series FN. Features High quality case with bajonet ring /160, degree of protection IP 66 Nominal ranges -40 C 700 C, further nominal ranges from -200 C...700 C upon request
More informationBACK WASH INSIDE THE SPA
BACK WASH INSIDE THE SPA Lower the temperature to 90 degrees and let the unit run approximately 10-15 minutes. This gives the heating element the chance to cool down. Now unplug the power pack Using a
More informationSmoke extraction duct of sheet steel
Smoke extraction duct of sheet steel The accessories that are available, as for example inspection openings, steel grilles, plenum boxes, ceiling diffusers, splitter attenuators, bends, tees and connecting
More informationRA 431 B Angled tube. As at: 01/15/10 Time:17:17
Angled tube As at: 01/15/10 Time:17:17 Angled tube As at: 01/15/10 Time:17:17 Pos. Description Reference 01 Lower angled tube 436.255 02 Disk 436.340 03 Cylindrical screw M 10x35 P...487 HA 04 Upper handle
More informationAUTOMATIC MODULAR ICE-CUBE MAKER WITH VERTICAL EVAPORATOR SYSTEM
AUTOMATIC MODULAR ICE-CUBE MAKER WITH VERTICAL EVAPORATOR SYSTEM INSTRUCTIONS AND WARNINGS 24481 ed. 11-2007 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear
More informationPolyMax H1-10 Dutch Bucket System
112529 PolyMax H1-10 Dutch Bucket System *Actual system may differ. PolyMax Dutch Buckets Versatile PolyMax Dutch Buckets are ideal for both small- and large-scale hydroponic growing. STK# DIMENSIONS 112529
More informationCryoProbe System. Pneumatic Vacuum Operator User Manual. Version
CryoProbe System Pneumatic Vacuum Operator User Manual Version 002 The information in this manual may be altered without notice. BRUKER BIOSPIN accepts no responsibility for actions taken as a result of
More informationINSTALLATION INSTRUCTIONS # BURNER ASSEMBLY REPLACEMENT
INSTALLATION INSTRUCTIONS # 00-858726 BURNER ASSEMBLY REPLACEMENT C24GA BURNER ASSEMBLY REPLACEMENT Verify steamer has a K3 relay (1, Fig. 1) installed. If K3 relay is not in steamer, one must be installed
More informationInstructions. 110-KVD-CYSCH-AD-Z Chrome 110-KVD-CYSSS-AD-Z Stainless Steel Certifications. Single Handle, Pull-Down, Kitchen Faucet
Instructions *Image may vary slightly from actual product Tools Required Adjustable Wrench Groove Joint Pliers Pipe Wrench Phillips Screwdriver Pipe Tape or pipe thread compound Safety Tips If you solder
More information1 ESMA, Inc. P. O. BOX 734 * SOUTH HOLLAND, IL * (800) * FAX (708)
1 2 Instructions for Ultrasonic Washer E789 (U.L. Approved) 1. INTRODUCTION The E789 Automatic Ultrasonic Washer automatically performs a cleaning cycle, the major steps of which are: Ultrasonic cleaning
More informationCS TSV MIX-REGULUS CS TSV MIX REGULUS. Installation and Operation Manual CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems
www.regulus.eu CS TSV MIX-REGULUS Installation and Operation Manual CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems EN CS TSV MIX REGULUS CONTENTS: 1 Introduction 3 2 Connection dimensions
More informationInstallation and Operation Manual
Model EP-ASF1 How to install, operate and maintain your Automatic Sediment Filter If you have any questions or concerns when installing, operating or maintaining your Automatic Sediment Filter, call our
More informationClean Water Made Easy. CWS Time Clock Softener Installation & Start Up Guide. Questions?
Clean Water Made Easy www.cleanwaterstore.com CWS Time Clock Softener Installation & Start Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance
More informationIN-LINE MERMAID CONDENSATOR
IN-LINE MERMAID CONDENSATOR INSTALLATION MAINTENANCE & TROUBLESHOOTING GUIDELINES CONTROL MASTERS, INC. Mermaid Air Distributor 11623 Columbia Park Drive East Jacksonville, FL 32258 Phone: 904-260-9756
More informationSolar-Divicon and solar pump assembly. Please follow these safety instructions closely to prevent accidents and material losses.
Installation and service instructions for contractors VIESMANN Solar-Divicon and solar pump assembly Safety instructions Please follow these safety instructions closely to prevent accidents and material
More informationROTARY VANE VACUUM PUMPS Exploded View DuraVane Rotary Vane Pumps Oil-Lubricated RVL301HH
Exploded View Pumps RVL0HH 95 SOUTH WOODLAND AVENUE, MICHIGAN CITY, IN 0-57 Please visit our website at Page Number Reference TOLL-FREE: 888-95-5 TEL.: 9-8-0 FAX: 9-8-0 www.dekkervacuum.com DWG //05 RVL0HH
More informationCS TSV MIX REGULUS PUMP STATION - for boilers and heating systems
Instruction Manual CS TSV MIX REGULUS PUMP STATION - for boilers and heating systems EN v 1.1 CONTENTS: 1 Introduction 3 2 Connection dimensions of CS TSV MIX Regulus 3 3 Function description of CS TSV
More informationOWNER S MANUAL. How to install, operate and maintain your. EcoWater Systems Automatic Sediment Filter
OWNER S MANUAL How to install, operate and maintain your EcoWater Systems Automatic Sediment Filter Model EASF1 EcoWater Systems LLC P.O. Box 64420, St. Paul, MN 55164-0420 7301805 (Rev. C 8/26/08) Table
More informationLYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS
www.regulus.eu LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE EN LYRA 1000 VVS CONTENTS 1 Description... 3 1.1 Models... 3 1.2 Tank protection... 3 1.3 Thermal insulation...
More informationDecentralised ventilation units
Notes on installation Decentralised ventilation units FSL / SCHOOLAIR GB/en TROX GmbH Heinrich-Trox-Platz 47504 Neukirchen-Vluyn Germany Phone: +49 (0) 2845 2020 Fax: +49 (0) 2845 202265 E-mail: trox@trox.de
More informationSERIES NIM. Low Temperature Merchandisers PLEASE READ THIS MANUAL BEFORE USING THE PRODUCT
SERIES NIM Low Temperature Merchandisers PLEASE READ THIS MANUAL BEFORE USING THE PRODUCT Hussmann Monterrey, Mexico Carretera Mexico-Laredo KM. 1009 Cienga de Flores, Nuevo Leon 65550 Mexico Phone: (52)
More informationMERMAID CONDENSATOR INSTALLATION MAINTENANCE & TROUBLESHOOTING GUIDELINES
MERMAID CONDENSATOR INSTALLATION MAINTENANCE & TROUBLESHOOTING GUIDELINES Mermaid Manufacturing of Southwest Florida, Inc. 2651 Park Windsor Drive, Suite 203 Fort Myers, Fl 33901 Phone: 800 330-3553 Fax:
More informationOil burners fuel unit with solenoid valve
Oil burners fuel unit with solenoid valve Type VM www.deltapumps.com VM1 - VM4U flanged Certified Quality System Printed in Italy - DE112/0404 Oil burners fuel unit with solenoid valve Type VM The DELTA
More informationTOWEL WARMERS ARE HEAVY! WE RECOMMEND THAT TWO PEOPLE INSTALL THE TOWEL WARMER!
1. Please follow instructions carefully to ensure that the towel warmer is properly attached to the wall or floor. FAILURE TO FOLLOW THESE STEPS COULD RESULT IN PROBLEMS. 2. Do not use an abrasive or chlorine-based
More informationOperation and Maintenance Manual 120V/60HZ
Operation and Maintenance Manual 120V/60HZ GLACIER CS5-16-VD CS5-16-VD-TB CS5-18-VD CS5-18-VD-TB AVALANCHE CS6-36-1D CS6-36-VD BLIZZARD CS6-50-VD Operation & Maintenance Manual 60HZ Models Table of Contents:
More informationGlobal-Tek (Singapore) Pte Ltd
Global-Tek (Singapore) Pte Ltd Door Type G-TEK G-TEK WWW.GLOBAL-TEK.COM.SG 1 P a g e Door Type, CONTENTS Wash and Rinse Arm Assembly....... 3-4 Booster Heater... 5-6 Wash Chamber.. 7-8 Door Lift Assembly...9-10
More informationkéìíê~=iqd=qìåöëíéå=dêáåçéê= lééê~íáçåë=j~åì~ä=
NJUMMJVQQJOOQP ïïïk~êåjòçåékåçã kéìíê~iqdlééê~íáçåëj~åì~ä m^dbnlcnm kéìíê~iqdqìåöëíéådêáåçéê lééê~íáçåëj~åì~ä ^o`jwlkbk`lj IfåÅ. OMVNi~ëm~äã~ëaêáîÉpíÉK` `~êäëä~çi`^vomnnjnrrn qéäwtsmkvpnknrmm UMMKVQQKOOQP
More informationInstructions. Certifications CH Chrome SS Stainless Steel. Single Handle, Industrial Style, Pull-Down Kitchen Faucet.
Instructions *Image may vary slightly from actual product Tools Required Adjustable Wrench Groove Joint Pliers Pipe Wrench Phillips Screwdriver Pipe Tape or pipe thread compound Safety Tips If you solder
More informationA AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1
A AD Oil burners fuel unit deltapumps.com DE116-0709 A-AD_en_0709.pdf - 16.11.09 Page 1/1 Oil burners fuel unit Type A, AD 1- Applications The DELTA aluminium fuel unit type A is an efficient and modern
More informationInstallation. Leveling
Your refrigerator was packed carefully for shipment. Remove and discard shelf packaging and tape. Do not remove the serial plate. Location Do not install refrigerator near oven, radiator or other heat
More informationCONTENTS 1 INTRODUCTION 3 2 PRODUCT DESCRIPTION 4 3 GENERAL INFORMATION 5 4 INSTALLATION 6 5 USE 10 6 MAINTENANCE 12 REV.
CONTENTS 1 INTRODUCTION 3 2 PRODUCT DESCRIPTION 4 3 GENERAL INFORMATION 5 4 INSTALLATION 6 5 USE 10 6 MAINTENANCE 12 REV. 01 2 / 12 CHAPTER 1 - INTRODUCTION Thank you for purchasing a product from the
More informationROTARY VACUUM EVAPORATOR RVO 400 SD User manual
ROTARY VACUUM EVAPORATOR RVO 400 SD User manual Boeckel + Co (GmbH + Co) Kg. Roedingsmarkt 33, 20459 Hamburg, Germany Phone + 49 40 325627 0 Fax: + 49 40 425627 41 E-mail: info@boeco.com Web: http://www.boeco.com
More informationSCC-E Sample Gas Feed Unit. Operator s Manual 42/23-58 EN Rev. 1
SCC-E Sample Gas Feed Unit Operator s Manual 42/23-58 EN Rev. 1 Contents Page Preface 3 General Safety Information 4 Safety Tips for Handling Electronic Measurement Devices 5 Chapter 1 Chapter 2 Chapter
More informationStraight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield
Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield Straight pattern TRV & drain off lockshield pack Size Pattern No. Pack 1 Qty
More informationInstallation Instructions
Installation Instructions KFN 9855 ide en - CA Installation, repair and maintenance work should be performed by a Miele authorized service technician in accordance with national and local safety regulations
More informationInstallation Instructions
Installation Instructions For Fully Integrated NoFrost Combined Refrigerator-Freezers HC 2060/2061 HCB 2060/2061 7084 349-00 Important Please Read and Follow these Instructions These instructions contain
More information