ACCREDITED. Product range Code A2L Modulating temperature regulating unit for heating and cooling, with ALPHA2 L pump.

Size: px
Start display at page:

Download "ACCREDITED. Product range Code A2L Modulating temperature regulating unit for heating and cooling, with ALPHA2 L pump."

Transcription

1 Modulating temperature regulating unit for heating and cooling 7 series ACCREDITED ISO FM ا ٠١١٥٢/١٥ replaces /7 GB Function The temperature regulating unit is made to be used in radiant panel systems in combination with distribution manifolds. The modulating temperature regulating unit, comprehensive of digital temperature regulator, controls the temperature of the medium sent to the panels according to the actual thermal load. In this particular series, the temperature is regulated by a dedicated hydraulic unit equipped with a specific motorised three-way valve.it is supplied with removable differential by-pass kit for the primary circuit. This accessory is essential when there is a primary circuit circulation pump and the radiator circuits or fan coils are controlled by thermostatic or thermo-electric valves. In case of connection with a SEPCOLL or an hydraulic separator without primary pump, the kit can be removed and the hydraulic unit is connected directly. Reference Documentation - Tech. brochure Pre-assembled distribution manifolds for radiant panel systems 8...S series Product range Code 7.AL Modulating temperature regulating unit for heating and cooling, with ALPHA L - pump Technical specifications Materials Regulating unit with motorised three-way valve Body: brass EN 8 CB7S Headwork: brass EN CWN Obturator: stainless steel EN 88- (AISI ) Seals: EPDM Flow adapter unit Body: brass EN 8 CB7S Primary circuit by-pass kit Body: brass EN 8 CB7S By-pass valve: PPAG Spring: stainless steel EN 7- (AISI ) Shut-off valves Body: Ball: brass EN CW7N brass EN CWN, chrome plated Performance Medium: water, glycol solutions Max. percentage of glycol: % Adjustment temperature range: 7 78 C Primary inlet temperature range: C Max. working pressure: kpa ( bar) Min. working pressure: 8 kpa (,8 bar) Panel manifolds differential by-pass setting: kpa (. mm w.g.) Primary circuit differential by-pass setting: kpa ( mm w.g.) Temperature gauge scale: 8 C Pressure gauge scale: bar Connections: - primary circuit: / M (ISO 8-) - to regulating unit: F (ISO 8-) with nut - panel circuit outlets: / M - Ø 8 mm - outlet centre distance: mm Panel circuit differential by-pass graph Δp (mm w.g.) Δp (kpa),,, Flow rate (l/min) (m /h)

2 Trasformatore Convertitore AC V Hz A C V AC V D V E Hz ()A T con forme bar norm e C CL. ISPE S L 8 7 C 8 7 CAMERA CALEFF HOBBY BAGNO HOBBY BAGNO HOBBY BAGNO Digital regulator Three-point type Electric supply: V - / Hz Power consumption: VA Protection class: IP Actuator Three-point type Electric supply: V - / Hz Operating time: s (rotation ) Power consumption: 8 VA Auxiliary micro contact rating:,8 A Protection class: IP Max. ambient temperature: C Protective cover: self-extinguishing VO Head available at the regulating unit connections H (m w.g.) (kpa) Flow/return temperature probes NTC type Working range: - C Time constant:, s Response:. Ω at C Two-wire cable with /8 M connection Maximum temperature safety thermostat Factory setting: C ± C Protection class: IP Contact rating: A / V Minimum temperature safety thermostat Factory setting: C ± C Protection class: IP Contact rating: A / V Pump High-efficiency pump: model ALPHA L - Body: cast iron GG / Electric supply: V - / Hz Maximum ambient humidity: % Max. ambient temperature: C Protection class: IP Pump centre distance: mm Pump connections: / F (ISO 8-) with nut Note:,,,,8,,,,8, G (m /h) The pump can operate with constant or proportional pressure control which adapts the performance to the system requirements. For further details, see the pump installation instruction sheet supplied in the package. Insulation Material: closed cell expanded PE-X Thickness: mm Density: - inner part: kg/m - outer part: kg/m Thermal conductivity (DIN ): C:,8 W/(m K) C:, W/(m K) Coefficient of resistance to the diffusion of water vapour (DIN ): > Working temperature range: C Reaction to fire (DIN ): Class B Dimensions outlets 8 outlets outlets 8 7 / 7 A A A Code Panel outlets A 7CAL 7DAL 7EAL 7FAL 7GAL 7HAL 7IAL 7LAL 7MAL 7NAL

3 D V E A C V Hz ()A T bar norme CL. ISPESL 7 8 C 7 8 C CAMERA CAMERA 8 conforme Flow manifold equipped with flow meters and balancing valves. Trasformatore Convertitore AC V Hz AC V SYSTEM FLOW SYSTEM RETURN 7 Return manifold equipped with shut-off valves. End fittings with multi-position ball valves, automatic air vent, differential by-pass kit and fill/drain hose connection. BOILER FLOW BOILER RETURN Characteristic components Digital regulator for heating and cooling Three-way mixing valve Three-point actuator Hight-efficiency pump, ALPHA L - Flow temperature probe Return temperature probe 7 Adjustable drain cock 8 Tmin./Tmax. safety thermostats Flow and return temperature gauges with pocket Pressure gauge Primary circuit shut-off valves Primary circuit differential by-pass kit Max. RH% control probe Max. RH% control components Hydraulic diagram RT SF T C Digital regulator Transformer/Convertor Adjustable drain cock T C 8 7 ST Temperature gauge Temperature probe SR RT ST Humidity % probe Room thermostat Tmin./Tmax. safety thermostat Ball shut-off valve Motorised three-way valve Pressure gauge Pump BF BR Differential by-pass

4 Operating principle The medium temperature is regulated by a three-way mixing valve with a sector obturator comprehensive of an actuator managed by a specific digital controller. The controller receives the signal from two probes, flow probe on the mixing valve outlet and probe from the panel circuit return, and it controls the movement of the valve. The flow in the valve is regulated by a shaped obturator () that, by turning, closes or opens the hot water flow ports () and the water returning ports from the circuit () to adjust the desired flow temperature. Even if the secondary circuit thermal load or the inlet temperature from the boiler change, the mixing valve automatically adjusts the flow rates until it obtains the optimal flow temperature. PRIMARY INLET SECONDARY FLOW PRIMARY RETURN SECONDARY RETURN Construction details Regulating unit body The valve body, containing the thermal regulating device, is made out of a single casting with connections to the primary and secondary circuits. A specific internal channel carries the system return medium to the regulating valve, making it possible for the unit to be smaller in size and easy to connect. Flow unit The flow unit is made out of a single casting with the necessary ports to connect with the functional components such as the safety thermostat, temperature gauge, pressure gauge, drain valve and flow temperature probe. Reduced head losses The three-way mixing valve is equipped with a special obturator acting on calibrated water orifices. This ensures a high flow rate and a reduced size, while maintaining accurate temperature control, with no swinging due to sudden changes in thermal load. Electrical connections The actuator is electrically connected through an external plug-socket system with a protective rubber cap. This system does not require opening the lid to connect the cables. In this way, replacing the actuator (should this ever be necessary) is particularly easy to do. ϒC 7 8 Manual opening By removing the actuator, the valve can be opened-closed manually by using a screwdriver. Regulating way - primary inlet Fully closed Fully open open c l o s e open l o s e c

5 Differential by-pass kit for primary circuit Operation The differential by-pass kit for the primary circuit enables controlling the flow supplied to the heating elements connected before the outlet to the panel circuit regulating unit. Removable kit In case of an hydraulic circuit connected to a SEPCOLL or to an hydraulic separator without primary pump, the kit can be removed and the hydraulic unit is connected directly. The circuit shut-off valves, equipped with nut connection, can be removed easily and used directly on the unit. Connection without hydraulic separator or SEPCOLL Differential valve The differential valve is used to control the head in the primary distribution circuit. It aids the flow circulation towards the heating or cooling elements and limits overpressure if there are thermostatic or thermo-electric valves. The differential valve has a fixed setting that cannot be changed. It is preset to kpa, mean value for the loss of head in the primary circuit. Δp (mm w.g.) Δp (kpa) Direct connection to hydraulic separator or SEPCOLL,,, Flow rate (l/min) (m /h) Primary circuit by-pass kit The by-pass kit permits hydraulic separation between the primary and secondary circuits. This hydraulic separation optimizes the operation of the secondary circuit at the panels thus preventing the influence on the secondary circuit by any primary circuit flow rate variation. In this case, the flow rate through the respective circuits depends solely on the pump flow rate characteristics, preventing reciprocal influence due to their coupling in series. Two possible conditions of hydraulic balance are described here. The component is typically sized in order to have the following working rate: G primary = G secondary (inlet to the mixing valve) + G heating elements G primary maximum recommended:, m /h Secondary Gs Gp Primary Gprimary > Gsecondary Secondary Gs Gp Primary Gprimary < Gsecondary

6 Digital regulator 7 8 Operation The regulator receives the signal from the room thermostat to switch the pump on and to control the mixing valve. The regulator acts on the mixing valve following two operating logics, depending on the state of activation of the return sensor. Set point regulation: return probe off. Selector ) OFF. In this case the flow temperature FT is kept constant at the value set with the selector ) in both heating and cooling. This setting is shown on the display ). Modulating regulation: return probe on. Selector ) ON. In this case the flow temperature FT is changed according to the temperature measured by the return probe RT. In this way the actual thermal efficiency of the slab is kept under control and, as a result, the room s thermal load as well. This minimizes the system s thermal response times. RT set = FT set - % (FT set - C) FT calculated = FT set + (RT set - RT) Example: FT set = C RT set = -, ( - ) = C FT calculated = + ( - RT) The front panel identifies the following functions: ) Three-digit LCD indicating: the measured or calculated temperature and the settings of the delays programmed in the system. Temperature range displayed: C with resolution, C. ) Regulator ON/OFF function selector. ) Mixer on opening: LED on. ) Mixer on closing: LED on. ) Selector for setting the flow temperature. Temperature range 7 78 C Factory configuration: - heating: max C - cooling: min C ) Return probe selector. Probe off: OFF Probe on: ON Factory configuration: ON 7) Pump working (ON): LED on steady. 8) T.S. LED safety temperature. Continuously ON when the limit signalled by the safety thermostat or by the safety humidostat is reached. Continuously ON even if the flow/return sensors malfunction (see flow/return sensor paragraph). ) Heating/cooling function switch The new value of FT calculated is shown on the display ) with a side bar. At each update of the FT calculated, the FT measured is displayed for s, thereafter the new FT calculated is shown again. FT modification stops when RT reaches RT set. The return probe is not active in the cooling function. Curve correction graph with return probe FT;RT ( C) Designed flow temperature FT Set FT Calculated RT Set FT Calculated Return temperature designed Flow temperature limit FT Flow temperature ) Trimmer for maximum pulse duration on the valve. Adjustable, s. Factory configuration:, s. Pulse value calculation: % % % Designed thermal load % Tpulse (s) = Example: Tactuator rotation = s Tpulse = / = s Actuator rotation time (s) ) Return probe reading delay time trimmer. Adjustable s. Factory configuration: s. ) Valve-motor mechanical delay recovery trimmer. Adjustable s. Factory configuration: s. Display The three-digit LCD displays the following parameters: - flow temperature set with selector ). After s the measured flow temperature appears. - measured flow temperature, with return sensor off. - calculated flow temperature, with return sensor on. - maximum duration of pulse on the valve, selectable via trimmer ). Displayed for s. - return temperature acquisition delay time, selectable via trimmer ). Displayed for s. - valve-motor mechanical delay recovery, selectable via trimmer ). Displayed for s.

7 Back panel M V~ Hz ~ μ () A / V~ L N SA SR TA TS V~ IN OUT Apre Chiude Flow temperature limit for heating and cooling The regulator enables selecting the maximum flow temperature for heating and the minimum flow temperature for cooling. For this purpose, the regulator base contains specific dipswitches that enable setting different temperature limits. Factory configuration: - heating max C - cooling: min C. 7 8 Dipswitch position-temperature limit table On the back panel there are terminals for the electrical connections of the various components. Electric supply Electric supply V~ Live Electric supply V~ Neutral Ground/Earth Pump command Ground/Earth Pump command V~ Live Pump command V~ Neutral Mixer command 7 Valve command for opening 8 Common C Valve command for closing Auxiliary microswitch Auxiliary output N/O Auxiliary output common C Auxiliary output N/C Flow/return probe Flow temperature probe Common C Return temperature probe Ambient thermostat/safety thermostat Contact for ambient thermostat 7 Contact for common C ambient thermostat / Contact for common C safety thermostat and humidity probe convertor 8 Contact for safety thermostat and humidity probe convertor. Heating safety thermostat If the safety thermostat trips, on detecting a higher flow temperature than the setting, the following state comes into operation: pump OFF, mixing valve closed. The thermostat contact is N/C; if the connection fails, the regulator is not on. Auxiliary microswitch The regulator is equipped with an auxiliary microswitch that can be used to control other devices. Example: When Heating, to turn the water heater on/off. N/O contact - Pump stationary - ambient thermostat OFF or safety thermostat on (water heater off). N/C contact - Pump on - ambient thermostat ON (water heater on). When Cooling, to turn the refrigerating unit on/off. N/O contact - Pump stationary - ambient thermostat OFF or RH% limit probe on (refrigerating unit off). N/C contact - Pump on - ambient thermostat ON (refrigerating unit on). Contact capacity: A ( V). Flow/return probe The flow/return temperature probes are the NTC type. If the probes detect an ohmic resistance corresponding to short circuiting, the following operating state comes into operation: pump OFF, mixing valve closed, LED 8) on steady. Sensor resistance values table Setting Limit Limit Dipswitch maximum minimum ON Position Position Maximum temperature limit for cooling When cooling, the flow temperature can be selected no higher than C. Relative humidity control When using the cooling regulator, it is necessary to use the specific relative humidity probe. This probe has the task of measuring the limit of relative humidity so as to prevent condensation in the cooling slab. It is set for RH=8 8%. On reaching the setting, it triggers the following operating state: pump ON, mixer closed. Humidity probe control At the start of each cooling season, the operating state of the probe must be checked by placing a moist wad of cotton wool on its surface; this will cause the mixer to close and the red LED point 8 on the panel front to light up. Positioning the humidity probe Depending on the system characteristics, the humidity probe is located where there is the greatest risk of condensation. It is placed with the carbon portion upwards, as shown in the following diagrams. E Top side: carbon Bottom side: housed on the cooling surface Steps for correctly positioning the max RH% limit probe. The probe is secured to the manifold installed in the zone where you want to check that the relative humidity RH% cannot exceed the safety values. It is secured by means of the two clamps, using the specific holes. By controlling the following parameters it is possible to reach the maximum heating power delivered by the panel. - Minimum flow temperature, selectable via selector () on front panel. - Relative humidity RH% limit point, checked with relative humidity probe. - Ambient temperature, checked via ambient thermostat - Temperature and relative humidity of the ambient air, checked via fan coil or dehumidifier. Caution: The RH% limit probe is used to prevent any condensation from forming. In rooms where there is cooling, there must always be suitable air treatment. E

8 D V E c o nf o r me n o rmei SPES L Humidity probe connection V Room thermostat RT Trasformatore A C V Hz V L N ~ ~ Digital regulator code Convertitore AC V Hz AC V ()A T V~ L N SA SR TA TS V~ IN OUT Apre Chiude Safety thermostat ST Accessories 78 Digital room chrono-thermostat. operating programmes with ON/OFF spark advance. Weekly programmable clock. Fitted for phone programmer. Three temperature levels + anti-freeze. -minute minimum programme. ON/OFF function with adjustable differential from, to C or proportional. Adjustable temperature with, C steps. SUMMER/WINTER switch. changeover switch output contact: 8 () A. Protection class: IP. The humidity probe is connected to the regulator by installing the transformer and convertor in between. If you want to monitor various zones at risk of condensation, the humidity probe must be connected to a suitable interface kit (transformer, convertor and humidity probe). Up to convertors plus probes can be connected to a single transformer. Code x 8 x mm x 8 x mm x 8 x mm battery supply electric supply V built-in GSM module - supply V Application diagram Pump Lockshield Variable speed pump Shut-off valve Three-way valve Clock Thermostatic valve TH Thermostat/Humidostat E/I TH SPECIFICATION SUMMARIES Code 7.AL Modulating temperature regulating unit for heating and cooling. Connections to the primary circuit / M (ISO 8-). Connections to the regulating unit F (ISO 8-) with nut. Panel circuit outlet connections / M - Ø 8 mm. Medium: water and glycol solutions; maximum percentage of glycol %. Adjustment temperature range 7 78 C. Temperature range at primary circuit inlet C. Maximum working pressure kpa ( bar), minimum working pressure 8 kpa (,8 bar). Panel manifolds differential by-pass setting kpa. Primary circuit differential by-pass setting kpa. Temperature gauge scale 8 C. Pressure gauge scale bar. Complete with: flow manifold for panel system with outlets (from to ) with brass body, flow rate regulating valve with flow meter with a scale of l/min; return manifold for panel system with outlets (from to ) with brass body, shut-off valve. Regulating unit with motorised three-way valve, three-point actuator, electric supply V - / Hz, protection class IP. Digital regulator, electric supply V - / Hz, complete with probes measuring temperature of flow, return and relative humidity. Flow adapter unit with brass body. By-pass kit with brass body, PPAG differential by-pass valve and stainless steel spring. Shut-off valves with brass body and chrome plated brass ball. Maximum temperature safety thermostat: factory setting C ± C; minimum temperature safety thermostat: factory setting C ± C, protection class IP, contact rating A / V. High-efficiency ALPHA L - pump, protection class IP. Pre-formed PE-X shell insulation for primary circuit. Supplied preassembled in a painted plate box with lock, depth adjustable from to mm, including floor supports adjustable in height from 7 to mm. We reserve the right to make changes and improvements to the products and related data in this publication, at any time and without prior notice. Caleffi S.p.A. S.R. n. 8 Fontaneto d Agogna (NO) Italy Tel. + 8 Fax + 87 info@caleffi.com Copyright Caleffi

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump Set point temperature regulating unit series ACCREDITED ISO 9 FM / GB replaces dp / GB Function The temperature regulating unit is made to be used in radiant panel systems, in combination with distribution

More information

CALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB.

CALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit series cert. n ISO / GB Function The modulating temperature regulating unit with high temperature distribution

More information

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB Set point thermostatic regulating unit 8 series FM 65 00 CALEFFI 090/8 GB replaces dp 090/5 GB Function The thermostatic regulating unit is made to be used in radiant panel systems, in combination with

More information

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function Thermostatic regulating unit for heating systems 66 series ACCREDITED ISO 9 FM 6 8/7 GB replaces dp 8/ GB Function The thermostatic regulating unit performs the function of keeping the flow temperature

More information

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE RADIANT PANEL CONTROL QUICK GUIDE 05 RADIANT PANEL CONTROL Terms and definitions The system temperature regulation can be carried out in only two basic ways: Flow rate control of the medium feeding the

More information

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C. Anti-condensation circulation unit 8 series ACCREDITED ISO 9 F 654 ISO 9 No. CALEFFI 5/4 GB replaces dp 5/ Function The anti-condensation circulation unit performs the function of connecting the solid

More information

Convertible radiator valve for one-pipe systems, centre distance 35 mm

Convertible radiator valve for one-pipe systems, centre distance 35 mm Convertible radiator valve for one-pipe systems, centre distance 35 mm 56 series ACCREDITED ISO 900 FM 65 033/6 GB Function 56 series convertible radiator valves are used on one-pipe radiator systems.

More information

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve Connection and energy management compact unit 2850 series ACCREDITED CALEFFI 01259/14 GB ISO 9001 FM 21654 ISO 9001 No. 0003 Function The connection and energy management compact unit enables combining

More information

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB 4 RESET ON DHW CH FAULT SATK wall-mounted heat interface unit Fitted for connection to DHW storage SATK4 series ACCREDITED CALEFFI 6/4 GB ISO 9 FM 64 ISO 9 No. The latest generation of heat interface units

More information

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function Anti-condensation recirculation and distribution unit 8 series ACCREDITED ISO 900 FM 654 ISO 900 No. 000 CALEFFI 04/4 GB Replaces dp 04/ GB GB Function The anti-condensation recirculation and distribution

More information

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production SATK0 - SATK0 series ACCREDITED ISO 900 FM 009/ GB replaces dp 009/ GB Function The latest generation of Heat Interface

More information

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit Multi-function compact unit for temperature control, thermal disinfection and distribution for hydraulic and domestic water system 6005 series ACEDITED ISO 9001 FM 21654 01160/17GB replaces dp 01160/08GB

More information

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function Solar storage-to-boiler thermostatic connection kit 6-63 series REGI STERED BS EN ISO 900:000 Cert. n FM 64 UNI EN ISO 900:000 Cert. n 0003 CLEFFI 064/09 GB Function The solar storage-to-boiler connection

More information

Mercury Mixing Kit (Code: ME1053)

Mercury Mixing Kit (Code: ME1053) Mercury Mixing Kit (Code: ME1053) The installation and commissioning of the UFH mixing kit system must be exclusively performed by qualified personnel in accordance with the national guidelines and/or

More information

geothermal march 2011

geothermal march 2011 geothermal march 2011 General information Office hours: Monday to Friday 8.30am - 5.00pm. Prices: Prices are exclusive of VAT, and are subject to change without notice. All prices displayed are recognised

More information

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES FUNCTION Thermostatic expansion valves are used to regulate and cut-off the flow of the heat transfer fluid that circulates inside airconditioning system terminals (radiators, fan coils, etc.). Thermostat

More information

Function series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc)

Function series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc) onvertible radiator valve for one-pipe and two-pipe systems series ARIT 0/ G ISO 0 M ISO 0 No. 000 unction The series convertible radiator valve can be used both on one-pipe and two-pipe radiator systems.

More information

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING

More information

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE 780EN www.caleffi.com Recess Mounted Heat Interface Unit - SATK series SATK0-60 series INSTRUCTIS FOR INSTALLATI, COMMISSIING AND MAINTENANCE Function The SATK series HIU allows independent control of

More information

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES FUNCTION Thermostatic expansion valves are used to regulate and cut-off the flow of the heat transfer fluid that circulates inside airconditioning system terminals (radiators, fan coils, etc.). Thermostat

More information

Metering systems 0548EN April 2014

Metering systems 0548EN April 2014 08EN April 0 0U8 GEY - Y - Y (GE- series) 900 000/ 00 00A/ 800 00L/ Versions and product codes Product code Type Heat exchanger nominal power GEY, - GEY and production GEY and production Table - Product

More information

4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems.

4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems. 4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems. CT3101.0_00 EN June 2016 o o o o Valve with pre-adjustment; Variable centre

More information

Introduction. Application. Technical data

Introduction. Application. Technical data FLOOR HEATING SYSTEM 01 E3... Heating Thermostat with LCD Screen Heating thermostat with LCD screen,which has manual mode and energy saving mode.the thermostat is recommended for the control of electric

More information

Systems for central heating

Systems for central heating www.far.eu Highlight Systems and Components for central heating Components for renewable energy systems Pressfar Fittings Presetting valves and thermostatic head Balancing devices Zone valves Metering

More information

DISCALDIRT deaerator-dirt separator

DISCALDIRT deaerator-dirt separator DISLDIR deaerator-dirt separator 6 series REDIED ISO 900 M 6 ISO 900 No. 000 0/ G replaces dp 0/0 G unction Deaerators-dirt separators are used to continuously eliminate the air and dirt contained in the

More information

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump Reduced Installation time Precision regulation Minimal tooling required 100% tested prior to packaging High quality

More information

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES ST.07.05.00 THERMOSTIC SINGLE-PIPE AND DOUBLE-PIPE VALVES 1. Art.1420 THERMOSTIC SINGLE-PIPE VALVE Single-pipe valves allow manual, thermostatic or thermo-electric regulation. Separation of the lockshield

More information

CONTROL UNIT FOR UNDERFLOOR HEATING SYSTEMS

CONTROL UNIT FOR UNDERFLOOR HEATING SYSTEMS ST.04.04.00 ONTROL UNIT FOR UNERFLOOR HETING SYSTEMS Low temperature control unit Low+high temperature control unit 1. ONTROL UNIT PPLITION The FR control unit is suitable for systems combining both high

More information

R557R EN January 2012

R557R EN January 2012 R7R- 077EN January 0 07U 00 00 00 WITH HIGH TEMPERATURE MANIFOLDS Example: R7RY0 + RAY00 R7R- WITH THERMAL ENERGY METERING Description R7R- group is used for the regulation of the fixed point heating for

More information

Dynamic thermostatic radiator valves DYNAMICAL

Dynamic thermostatic radiator valves DYNAMICAL ynamic thermostatic radiator valves YNMIL -----7 series RIT ISO 9 M 6 /7 G unction The YNMIL valve allows the automatic dynamic balancing and pressure-independent adjustment of the thermal medium in the

More information

R586R. Distribution and Regulation units. Datasheet 0861EN 04/2019 R586RY103 R586RY102 R586RY101 R586RY104

R586R. Distribution and Regulation units. Datasheet 0861EN 04/2019 R586RY103 R586RY102 R586RY101 R586RY104 R8R Distribution and Regulation units Datasheet 08EN 0/09 R8RY0 R8RY0 R8RY0 R8RY0 Unit with insulation and actuator (optional) R8RY R8RY R8RY R8RY R8R distribution units control heating and cooling for

More information

Wall-mounted compact indirect heat interface unit SATK30 series Safety instructions Dimensions Technical specifications Installation Commissioning

Wall-mounted compact indirect heat interface unit SATK30 series Safety instructions Dimensions Technical specifications Installation Commissioning 78.0EN www.caleffi.com Wall-mounted compact indirect heat interface unit SATK0 series INSTRUCTIS FOR INSTALLATI, COMMISSIING AND MAINTENANCE Function The SATK series HIU allows independent control of heat

More information

b!klimax Ceiling and Wall Radiant System. Innovative Wellbeing.

b!klimax Ceiling and Wall Radiant System. Innovative Wellbeing. b!klimax Ceiling and Wall Radiant System. Innovative Wellbeing. b!klimax is an integrated heating and cooling system that exploits the ability of ceilings and walls to exchange heat and cold with the environment

More information

SPECIFICATIONS - NIKE

SPECIFICATIONS - NIKE Wall-mounted instant boilers NIKE Mini kw Special is the ideal Immergas solution for modern building and wherever space is limited and has to be made the most of. Simple to use and easy to install, thanks

More information

caleffi hydronic valves page 1 of 12

caleffi hydronic valves page 1 of 12 caleffi hydronic valves page 1 of 12 page 2 of 12 MANUAL RADIATOR VALVES 1601811 - Series 340 1601812 - Series 341 1603748 - Seies 411 1603749 - Series 412 CONVERTIBLE RADIATOR VALVES 1601816 - Series

More information

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold Dynalux Floor Heating Manifolds Underfl oor heating circuit manifold IMI HEIMEIER / Floor Heating Control / Dynalux Dynalux Dynalux adjusts the flow rate in the individual heating circuits directly in

More information

PRE-ASSEMBLED MANIFOLD FOR HEATING SYSTEMS WITH THERMOSTATIC MIXING

PRE-ASSEMBLED MANIFOLD FOR HEATING SYSTEMS WITH THERMOSTATIC MIXING PRE-ASSEMBLED MANIFOLD FOR HEATING SYSTEMS WITH THERMOSTATIC MIXING R557 SUMMARY 1. APPLICATION 1. OPERATING 2. COMPONENTS 3. OVERALL DIMENSIONS 4. APPLICATION EXAMPLE 6. POSITIONING OF THE HEAD WITH THERMOSTATIC

More information

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank 1 FEATURES Wall-mounted with storage tank Compact wall-mounted open chamber boiler with conventional flue and 45 litre stainless steel storage tank and nominal heat output of 23.7 kw (20,382 kcal/h). AVIO

More information

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE CT0031.0_10 EN August 2016 THERMOSTATIC RADIATOR VALVES * * * * 028 * LICENSED USE OF TRADEMARK NR. 43 PRODUCTION RANGE IRON

More information

A/23 MFFI - A/27 MFFI

A/23 MFFI - A/27 MFFI A/23 MFFI - A/27 MFFI G.C.N. 47-6-0 / 47-6-2 Servicing Instructions Type C Boilers LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER TABLE OF CONTENTS Page No.. SERVICING INSTRUCTIONS. Replacement of

More information

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS

SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS SOTTOSTAZIONI PER TELERISCALDAMENTO DISTRICT HEATING SUBSTATIONS INDEX Ed. 20150422 GENERAL INFORMATION... 2 Before installing... 2 Materials and PED (97/23/CE) Standards... 3 SKID-TYPE DISTRICT HEATING

More information

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.00 kw -. kw PHRT.0 kw /.0 kw

More information

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise. Flush Individual Room Control for Floor Heating Systems To be precise. Contents Page Multibox K, Multibox RTL and Multibox K-RTL Description Construction Application 4 Temperature Setting 4 Function Article

More information

b!klimax radiant wall/ceiling system

b!klimax radiant wall/ceiling system b!klimax radiant wall/ceiling system by We have been working in an ideal climate for thirty years. A climate that has brought us to a position of leadership in Italy in the field of radiant heating and

More information

Roth fixed-value control set with high-efficiency pump

Roth fixed-value control set with high-efficiency pump Energy Systems Roth fixed-value control set with high-efficiency pump Assembly Instructions Living full of energy Contents General information Intended use 3 Benefits 3 Layout/Components 3 Installation/Electrical

More information

Servicing Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER

Servicing Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER Servicing Instructions Type C Boilers G.C.N: 4-6-0 47-6-08 47-6-09 47-6-3 LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER TABLE OF CONTENTS Page No.. SERVICING INSTRUCTIONS. Replacement of Parts 3.2

More information

ACCUMULATION OF EUROPEAN CLASS

ACCUMULATION OF EUROPEAN CLASS ACCUMULATION OF EUROPEAN CLASS Total comfort MODEL nominal output kw minimum output kw DUA PLUS B TN DUA PLUS B TFS natural draught room sealed forced draught 28 12.4 28 12.4 DUA PLUS B was born from the

More information

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories > HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base

More information

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw TECHNICAL INSTRUCTIONS CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw CHG 1 CHG 1 8. kw. kw.7 kw 1. kw April 7 19 - GB - 2 MARKING This product marked conforms to the essential

More information

8008 CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN.

8008 CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN. 8008 CIRCULATION UNIT FOR SOLAR THERMAL SYSTEMS, FLOW AND RETURN. FUNCTION: Circulation units for solar thermal systems are used in the primary circuit of solar heating systems to control the temperature

More information

Installer Manual KNX Touchscreen Thermostat

Installer Manual KNX Touchscreen Thermostat Installer Manual 02952 KNX Touchscreen Thermostat Index GENERAL FEATURES AND FUNCTIONALITY from page 5 ETS PARAMETERS AND COMMUNICATION OBJECTS from page 7 COMMUNICATION OBJECTS GENERAL FEATURES AND FUNCTIONALITY

More information

Ideasandformsinevolution

Ideasandformsinevolution Ideasandformsinevolution TYPE natural draught room sealed electric diverting valve RTN 24 CTN 24 E RTFS 24 CTFS 24 E DUA PLUS is a natural draught or room sealed forced draught wall hung gas boiler, with

More information

INSTRUCTIONS REHAU SILENT DIAL THERMOSTAT #

INSTRUCTIONS REHAU SILENT DIAL THERMOSTAT # INSTRUCTIONS REHAU SILENT DIAL THERMOSTAT #236477-001 Specifications... 1 Overview Silent Dial Thermostat Art. 236477-001... 1 Mounting Location... 3 DIP Switch Configuration... 3 Calibration... 5 Setting

More information

DEVIATING VALVES ART K063

DEVIATING VALVES ART K063 FUNCTION The flow diverter valve Art.307 makes it possible to supply a branch circuit. Prepared to receive our electro-thermal controls Art. 978, 979, 980 or our thermostatic heads with remote sensor Art.

More information

Thermostatic Radiator Valves (Caleffi)

Thermostatic Radiator Valves (Caleffi) 02/09/16 B46 Thermostatic Radiator Valves (Caleffi) Thermostatic Control Heads Thermostatic control head fits radiator valves Set point locking mechanism Range stop adjustment Built-in sensor with liquid-filled

More information

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB R407C EASY_R Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans 5,2 41,5 kw T_ESY_R_0508_GB EASY_R R407C INDEX WORKING LIMITS... 3 SERIES IDENTIFICATION... 4 MODEL

More information

REA22 Room Temperature Controller

REA22 Room Temperature Controller REA22 Room Temperature Controller Basic Documentation Issue: 2.0 Controller series: A CE1P2276E 31.03.1999 Siemens Building Technologies Landis & Staefa Division Siemens Building Technologies Ltd. Landis

More information

kw COOLING kw HEATING

kw COOLING kw HEATING Heat pump water/water liquid chillers for indoor installation. Inversion on hydraulic circuit. 394 1505 kw COOLING 477 1976 kw HEATING technicalcatalogue T_FRGSCRWP_0913_GB INDEX GENERAL CHARACTERISTICS...

More information

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve VENT APPENDIX A: PIPING SYMBOL LEGEND GENERIC COMPONENTS CALEFFI COMPONENTS circulator circulator w/ ThermoBloc union circulator w/ swing check spring loaded balancing balancing w/ gate check globe s purging

More information

Self-learning Room Temperature Controller

Self-learning Room Temperature Controller 2 257 Self-learning Room emperature Controller 5 operating modes and menu selection via roller selector REV16 Mains-independent room temperature controller Straightforward, self-explanatory menu selection

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue cert. n. 0545 Product is subject to and complies with Regulation (UE) N.327/2011 Fan Coil Unit Cassette SkyStar Jumbo ECM technical catalogue SkyStar Jumbo ECM Table of contents SkyStar Jumbo ECM TABLE

More information

Thermostatic head with wax sensor

Thermostatic head with wax sensor Combined with valves covered by EN215 01 november 2004 ı Technical communication n da Use In modern society research concerning comfort in the home becomes a factor of prime importance. In order to obtain

More information

Flush individual room control for floor heating systems

Flush individual room control for floor heating systems Multibox Flush individual room control for floor heating systems Pressurisation & Water Quality Balancing & Control Thermostatic Control ENGiNEERiNG ADVANTAGE Multibox is used for decentralized control

More information

Technical Product Guide

Technical Product Guide FMU - Floor Mixing Unit Boxed set pre-assembled for immediate installation: The FMU Floor Mixing Unit integrates both temperature and flow management, making the single piece unit very easy to install,

More information

Heating controller Lago

Heating controller Lago Heating controller Lago Product brochure GB 10 Edition 02.08 Wall-mounted (Lago Basic 0101/1001 and Lago 0321) Boiler or control panel attachment (Lago 0201R) Simple operation and programming Automatic

More information

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01

More information

Installation, commissioning and servicing instructions. Technical Characteristics. -Lead Plumbing Law Certifi ed by IAPMO R&T

Installation, commissioning and servicing instructions. Technical Characteristics. -Lead Plumbing Law Certifi ed by IAPMO R&T www.caleffi.com 37. MixCal adjustable three-way thermostatic mixing valve Copyright Caleffi Installation, commissioning and servicing instructions Series Function The Caleffi MixCal three-way thermostatic

More information

Water chillers water/water type SIGMA Technical information manual

Water chillers water/water type SIGMA Technical information manual Water chillers water/water type SIGMA Technical information manual 2 INDEX Technical features 1 Versions 3 Accessory versions 4 Technical data 7 Electrical data 11 Cooling capacity 12 Heating capacity

More information

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side s Frost detector for use on the air side QAF64.2-J QAF64.6-J With active capillary tube sensing element for acquiring the lowest temperature within a range of 0 15 C With startup function Operating voltage

More information

CRIMSON & CRIMSON MAX

CRIMSON & CRIMSON MAX High efficiency water/water and geothermal heat pumps 5 114 General High efficiency water/water and geothermal heat pumps. Ideal for heating, cooling and production of domestic hotwater with total or partial

More information

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX Duct unit DUCTIMAX Medium available static pressure ducted hydronic units DUCTIMAX - 8 kw NEW PRODUCT JUNE 05 Performance and compactness in recessed ceiling installations ERGO Supervision Plus -pipe system

More information

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017 Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air

More information

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power VICTRIX 90 is the new wall-hung condensing boiler for room heating only, set-up for independent functioning and for that in cascade mode

More information

CLIMAV 2.0 Thermoregulation Systems

CLIMAV 2.0 Thermoregulation Systems Thermoregulation Systems EN 2 TIEMME, INNOVATION FOR A STEADY GROWTH Tiemme Raccorderie is an international leader in the production and marketing of plumbing and heating components. Experience, innovative

More information

Composite under-boiler dirt separator with magnet DIRTMAG

Composite under-boiler dirt separator with magnet DIRTMAG omposite under-boiler dirt separator with magnet IRTMG 55-55 - 55 series 07/7 G REITE ISO 900 FM 65 replaces dp 07/6 G Function The IRTMGSLIM dirt separator separates off the impurities contained in air-conditioning

More information

Line. Floor Heating and Cooling Systems

Line. Floor Heating and Cooling Systems Line Floor Heating and Cooling Systems THE COMPANY The history of NUPIGECO began in 1972: two distinct companies joined forces to give rise to one large manufacturing company. The strong points of our

More information

Environmental Chambers

Environmental Chambers Temperature (& ) Chambers Dimensions (TH-G / TH-I / TC-G series) 115 Models Capacity W D H A B TH-G TH-I TC-G TH-G TC-G 180L (6.4cu ft) 1025mm (40.4 ) 1035mm (40.7 ) 1530mm (60.2 ) 450mm (17.7 ) 1230mm

More information

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

5231 Series.   Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341 NA31 www.caleffi.com Low Lead High Flow Thermostatic Mixing Valves Copyright 1 Caleffi Installation, commissioning and service instructions Function 531 Series ASSE 17 model 531 series high flow thermostatic

More information

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control. product selection data Compact comfort module DHW management possibility Multi zone option control Easy installation Comfort module with two-zone kit Single-zone comfort module Comfort Module Range for

More information

281 Series. ThermoBloc boiler protection recirculation and distribution unit. Installation, commissioning and servicing instructions

281 Series. ThermoBloc boiler protection recirculation and distribution unit.   Installation, commissioning and servicing instructions www.caleffi.com NA1094.01 ThermoBloc boiler protection recirculation and distribution unit Copyright 013 Caleffi Installation, commissioning and servicing instructions 81 Series Function The ThermoBloc

More information

Self-learning Room Temperature Controller

Self-learning Room Temperature Controller 2 252 Self-learning Room emperature Controller with one weekly operating mode including individual 24-hour modes and three 24-hour modes, cooling function REV22 Use Mains-independent room temperature controller

More information

DUO PLUS. Instruction manual

DUO PLUS. Instruction manual DUO PLUS Instruction manual 2 SUMMARY 1. Introduction pag. 3 2. Technical data 4 3. Display readings key 6 4. Thermostat controls key 7 5. Dimensions 8 6. Installation and connections 9 7. Thermostat start-up

More information

RVL470. Heating Controller. Use. Functions. Series B

RVL470. Heating Controller. Use. Functions. Series B 2 522 Heating Controller Series B RVL470 Multifunctional heating controller for use in residential and non-residential buildings; suitable for weather-dependent flow temperature control of heating zones

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are

More information

Room Temperature Controllers

Room Temperature Controllers 3 021 Room Temperature Controllers for two-pipe fan coil units RCC10 Output for on / off valve actuator Outputs for three-speed fan Control depending on the room or return air temperature (RCC10) Automatic

More information

Heating controller with optimisation functions

Heating controller with optimisation functions TAC 2112 C-10-42 Heating controller with optimisation functions 1999.12 The TAC 2112 offers for control of hot water systems. The radiator circuit is controlled according to an outdoor -compensated reset

More information

Immersion Temperature Controller

Immersion Temperature Controller 3 333 Synco 100 Immersion emperature Controller with 2 outputs DC 0 RLE162 Immersion temperature controller for water-side control in heating and cooling plants Compact design with 2 analog control outputs

More information

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E Instantaneous wall-hung with open chamber boilers Small wall-mounted open chamber, conventional flue instant boiler. General features. is a wall-mounted, open combustion chamber, conventional flue generator

More information

product overview ProControl

product overview ProControl product overview ProControl 2016 product overview ProControl 2016 4 The company AFRISO Sp. z o.o. was founded in 1997. Since that time we keep doing our best to increase AFRISO brand awareness among Installers.

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

HYDROCIAT LW R407C. Water cooled chillers USE RANGE Screw compressors CIAT dry direct expansion shell and tubes evaporator HPS equipment (High Power System) cooling or heating Heat recovery ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT

More information

Metering Box METERING AND AMBIENT HEATING FOR HEATING SYSTEM. Overview. Application PRODUCT DATA

Metering Box METERING AND AMBIENT HEATING FOR HEATING SYSTEM. Overview. Application PRODUCT DATA Metering Box METERING AND AMBIENT HEATING FOR HEATING SYSTEM Overview PRODUCT DATA The Honeywell Substations series consist of the following products: Metering Box (this datasheet) Heat Interface Unit,

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

Geolo THE GROUND SOURCE HEAT PUMP PLUSES Geolo THE GROUND SOURCE HEAT PUMP PLUSES RENEWABLE TECHNOLOGIES Geolo is able to exploit the Energy present in the water and underground thanks to the geothermal exchangers. Soil and water absorb the solar

More information

Digital Room Thermostat for Heating Applications with 7-Day Time Program

Digital Room Thermostat for Heating Applications with 7-Day Time Program Specification Digital Room Thermostat for Heating Applications with 7-Day Time Program CONFORT CRONO (RDE100.1-EQ*) * internal model name Two-position control with ON / OFF relay output for heating Operating

More information

GHE. Dehumidifiers for radiant cooling systems with heat recovery. Display

GHE. Dehumidifiers for radiant cooling systems with heat recovery. Display GHE Dehumidifiers for radiant cooling systems with heat recovery Display The dehumidifiers with heat recovery of high efficiency series GHE were designed to provide dehumidification and fresh air in a

More information

CALEFFI DISCAL. deaerator-dirt separator DISCAL series ACCREDITED 01123/17 GB. replaces dp 01123/14 GB

CALEFFI DISCAL. deaerator-dirt separator DISCAL series ACCREDITED 01123/17 GB. replaces dp 01123/14 GB ISL deaerator-dirt separator ISL 46-461 series RI ISO 9001 M 2164 LI 01123/17 replaces dp 01123/14 unction eaerators-dirt separators are used to continuously eliminate the air and dirt contained in the

More information

Better Design, Better Control, Better Systems.

Better Design, Better Control, Better Systems. Product Catalog Better Design, Better Control, Better Systems. At tekmar Control Systems, we believe the indoor comfort of a building depends on the performance of its heating, ventilating & air conditioning

More information