1 RENTAL SOLUTIONS 2017/2018 Cooling power to go. acr chiller rent rental products of these areas... Refrigeration / Air Conditioning Heating Power supply Accessories Specialty plants Second hand FAQ Consulting, installation and service from a single source. For temporary refrigeration capacity needs. Environmentally sound, efficient and economical solutions.

2 acr chiller rent acr chiller rent specialists for rental solutions. Since its founding in 2004, managing director Bruno Trost has focused on the rental of refrigeration equipment and accessories. acr chiller rent in the fair city of Munich-Riem has grown along with the demands of its customers and is considered to be one of the top names in the industry throughout the German speaking countries. acr chiller rent can offer its customers financing models, long-term leasing and contracting. 2

3 Rental machinery and equipment - 40 megawatts of cooling power at your disposal. Our rental park includes continuously maintained units with a rated cooling capacity totaling 40 megawatts. The reconditioned units ranging from air- and water cooled chillers to Heat Pumps, Rooftops, Re-circulating air coolers and to turnkey as well as custom-configured refrigeration units to your specific applications, only to mention some of the most common classes. All equipment leased by acr are highly efficient in operation, safe and always on the cutting edge concerning environmental technology. acr chiller rent 3 Refrigeration and air-conditioning units of all classes. In all sizes. For every cooling requirement. acr has chillers in all categories: The Chillers offer cooling capacities from 1.8 to 4500 kw per unit. From 200 kw onward, screw compressors commonly are used and up to 400 KW a heat pump function can be ordered. Plate heat exchangers with a maximum rated capacity of 2,500 kw as well as any of the extensive rental accessories in the acr-range can be installed by our service team within 24 hours.

4 Areas of application 4 Examples - of good reasons to rent. Whether for production systems, food refrigeration, in pharmaceuticals and chemicals, climate improvement in office buildings or any other events, for dehumidification the reasons for renting air-conditioning and refrigeration equipment are diverse. Usually rental is even cheaper than buying. But for whatever reason you decide for a temporary solution to your cooling problem: acr chiller rent has the right answer for every question. With guaranteed performance, economical and environmentally friendly chillers, which will satisfy any requirement. Industries and scope of application» Facility management» Plastic industry» Pharmaceuticals and Chemicals» Energy provider» Automotive industry» Mechanical engineering» Hospital-/Health care technology» IT air-conditioning» Plant building» Refrigeration specialty business» Food-/Beverage industry» Event

5 Process cooling/ production cooling In manufacturing, a constant temperature level is a prerequisite to keep the production processes running as well as to guarantee quality standards. The process cooling must be guaranteed during temporary load peaks. The cooling media such as water, oil, Emulsions or air are kept to the required temperature level using the most modern dependable and efficient chillers and drycoolers from acr chiller rent. Areas of application 5

6 Areas of application 6 Air-conditioning The climatic conditions in inside rooms especially during the summer months and at peak load times can sustainably be optimized by mobile rental cooling. In offices, computer centers, at events in tents as well as in production halls and warehouses the available cooling capacity can be either enhanced or, entirely or partially replaced. All solutions for a fast and dependable rental air-conditioning increase your productivity, liquidity and competitiveness.

7 Heating A regulated heating source is indispensable for numerous processes in production, but also when the heating and warm water system is down, or an emergency heating in residential or office and administration complexes, on construction sites, or temporarily at Events on outside locations such as tents or containers. The acr chiller rental mobile heating systems deliver warm air or warm water dependably as required always and everywhere. We have ready a complete offer of heaters, heating systems as well as our extensive assortment of accessories, with which you can handle critical situations with ease. We can show you how you can effectively react to emergencies and bottlenecks by utilizing additional rental reserve capacities. Areas of application 7

8 Maintenace and service - We are always available! The acr chiller rent customers are always on the safe side. We offer complete and full service from consulting to installation and maintenance of the rented cooling system in your company. Our 24 hour service department with remote monitoring will also give you a safe feeling. If problems should arise during the rental period, a 24-hour emergency service is available. Service 8 acr always in your vicinity- Fast and competent customer care is guarantee by the service bases which are distributed all over, Austria and Switzerland and networked with the Munich headquarters. 12 Bases in, 2 in Austria and 2 in Switzerland

9 A selection from the acr chiller rent - customer list a mirror showing confidence References 9

10

11 Index 11 Refrigeration/Air Conditioning Page 13 Refrigeration/ Air Conditioning Heating Page 85 Heating Power supply Page 105 Power supply Accessories Page 111 Accessories Specialty plants Page 139 Specialty plants Second hand Page 141 Second hand FAQ Page 143 FAQ

12

13 13 Refrigeration/Air Conditioning Refrigeration/ Air Conditioning Liquid Chillers Page 14 Air-cooled Liquid Chillers 15 Water-Cooled Liquid Chillers 43 Mobile large scale refrigeration system 47 Low temperature units Page 50 Condenser units (up to -40 C) 51 Air-cooled Liquid Chillers (up to -15 C) 53 Water-cooled Liquid Chillers (down to -45 C) 57 Drycooler Page 60 Drycooler 61 Wetcooler 65 Air-conditioners / Ventilation systems Page 68 Air-conditioners 69 Air handling unit 71 Air conditioning cabinets 75 Rooftops / Ventilation systems 77 Humidification 83

14 14 Air-cooled Liquid Chillers Liquid Chillers Air-cooled Liquid Chillers 15 Water-Cooled Liquid Chillers 43 Mobile large scale refrigeration system 47

15 Air-cooled Liquid Chillers 15 Air-cooled Liquid Chillers The particularly compact units are ideal for exterior placement. With a capacity of 9 kw to 2,000 kw per cooler, fluids can be cooled in the temperature range between plus 25 C (can also be higher in conjunction with plate heat exchangers) and -15 C. The optional heat pump function configurable for alternating cooling or heating requirements as well as for use with the acr drycooler units for free cooling. The air-cooled acr rental fluid chillers can be applied in all areas where liquids are to be cooled. The areas of application are manifold: For example, the units are used in building air-conditioning, production processes, test setups, medical technology, pharmaceuticals, food processing, beverage industry, chemical industry, plastics industry, ice rinks, and in many other areas. The installation and integration is very simple: The air-cooled chillers in the acr rental park are designed for outdoor installation and can be installed on any viable ground. After connecting the pre-configured flexible hoses and the power cabling the mobile refrigeration unit can go into operation.

16 ACR-M-9/P Technical Specifications - Rental Chiller Quick overview: Scroll- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Sound level C R407C -8 C bis +20 C -20 C low noise Air-cooled Liquid Chillers Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring DN 40 Storz C up to 40m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 9 Power input kw 3,18 Voltage V/Hz/Phases 400/50/3 Operating current A 5,8 Electrical Connection CEE 16A ** Fuse protection A 16 ** Cable recommendation mm 2 2,5 Flow rate m 3 /h 1,5 Technical description: Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running scroll compressors. The fluid cooler has an integrated cold water pump head height of 1m (10kPa), it should be set up on a horizontal, stable work area and have at least 1m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 6 External pressure head m 1 Cold water connections Storz C Capacity control Steps 1 Refrigerant R 407C Sound pressure at 10m db(a) 52 Transport weight kg 220 Dimensions (l x w x h) mm 1320x730x1560 * Design conditions: Evaporator water temperatures 12/7, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist. Electrical connections with CEE-plugs Cold water connection with Storz-plugs

17 ACR-M-12/P Technical Specifications - Rental Chiller Quick overview: Scroll- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Sound level +40 C 17 R407C -8 C bis +20 C -20 C low noise Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring Air-cooled Liquid Chillers DN 40 Storz C up to 40m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 12 Power input kw 5 Voltage V/Hz/Phases 400/50/3 Operating current A 14 Electrical Connection CEE 16A ** Fuse protection A 16 ** Cable recommendation mm 2 2,5 Flow rate m 3 /h 2,0 Technical description: Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running scroll compressors. The fluid cooler has an integrated cold water pump head height of 19m (190kPa), it should be set up on a horizontal, stable work area and have at least 1m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 6 External pressure head m 19 Cold water connections Storz C Capacity control Steps 1 Refrigerant R 407C Sound pressure at 10m db(a) 51 Transport weight kg 225 Dimensions (l x w x h) mm ca. 1490x730x1670 * Design conditions: Evaporator water temperatures 12/7, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist. Electrical connections with CEE-plugs Cold water connection with Storz-plugs

18 ACR-M-15/P Technical Specifications - Rental Chiller Quick overview: Scroll- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Sound level C R410A -8 C bis +20 C -20 C low noise Air-cooled Liquid Chillers Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring DN 40 Storz C up to 40m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 15,0 Power input kw 5,3 Voltage V/Hz/Phases 400/50/3 Operating current A 19,4 Electrical Connection CEE 32A ** Fuse protection A 20 ** Cable recommendation mm 2 2,5 Flow rate m 3 /h 2,6 Technical description: Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running scroll compressors. The fluid cooler has an integrated cold water pump head height of 8m (80kPa), it should be set up on a horizontal, stable work area and have at least 1m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 8 Cold water connections Storz C Capacity control Steps 2 Refrigerant R 410A Sound pressure at 10m db(a) 52 Transport weight kg 220 Dimensions (l x w x h) mm ca. 1490x730x1670 * Design conditions: Evaporator water temperatures 12/7, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist. Electrical connections with CEE-plugs Cold water connection with Storz-plugs

19 ACR-M-20/P Technical Specifications - Rental Chiller Quick overview: Scroll- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Sound level +40 C 19 R410A -8 C bis +20 C -20 C low noise Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring Air-cooled Liquid Chillers DN 40 Storz C up to 40m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 20 Power input kw 7,3 Voltage V/Hz/Phases 400/50/3 Operating current A 17 Electrical Connection Cable terminals 2,5 mm 2 ** Fuse protection A 20 ** Cable recommendation mm 2 2,5 Flow rate m 3 /h 2,8 Technical description: Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running scroll compressors. The fluid cooler has an integrated cold water pump head height of 11m (110kPa), it should be set up on a horizontal, stable work area and have at least 1m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 6 External pressure head m 11 Cold water connections Storz C Capacity control Steps 1 Refrigerant R 410A Sound pressure at 10m db(a) 51 Transport weight kg 250 Dimensions (l x w x h) mm 1300x700x1600 * Design conditions: Evaporator water temperatures 12/7, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist. Control cabinet with electrical connections Cold water connection with Storz-plugs

20 ACR-M-39/P Technical Specifications - Rental Chiller Quick overview: Scroll- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Sound level C R407C -10 C bis +20 C -20 C low noise Air-cooled Liquid Chillers Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring DN 40 Storz C up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 39 Power input kw 15,5 Voltage V/Hz/Phases 400/50/3 Operating current A 29 Electrical Connection CEE 63A ** Fuse protection A 35 ** Cable recommendation mm 2 6 Flow rate m 3 /h 6,5 Technical description: Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running scroll compressors. The fluid cooler has an integrated cold water pump head height of 10m (100kPa), it should be set up on a horizontal, stable work area and have at least 1m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 10 Cold water connections Storz C Capacity control Steps 2 Refrigerant R 407C Sound pressure at 5m db(a) 62 Transport weight kg 560 Dimensions (l x w x h) mm 2200x1210x1490 * Design conditions: Evaporator water temperatures 12/7, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist. Electrical connections with CEE-plugs Cold water connection with Storz-plugs

21 ACR-M-60/WP/P Technical Specifications - Rental Chiller Quick overview: Scroll- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Heat pump function +40 C 21 R410A -10 C bis +20 C -20 C bis +45 C Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring Air-cooled Liquid Chillers DN 80 Storz B up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 60 Power input kw 18,2 Voltage V/Hz/Phases 400/50/3 Operating current A 60,5 Electrical Connection Cable terminals - ** Fuse protection A 63 ** Cable recommendation mm 2 16 Flow rate m 3 /h 9,72 Technical description: Air cooled corrosion resistant chiller with heat pump version for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running scroll compressors. The fluid cooler has an integrated cold water pump head height of 12m (120kPa), it should be set up on a horizontal, stable work area and have at least 1m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 12 Cold water connections Storz B Capacity control Steps 2 Refrigerant R 410A Sound pressure at 5m db(a) 58 Transport weight kg ca Dimensions (l x w x h) mm 2870x1200x2020 * Design conditions: Evaporator water temperatures 12/7, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist. Control cabinet with electrical connections Cold water connection with Storz-plugs

22 ACR-M-70/WP/P Technical Specifications - Rental Chiller Quick overview: Scroll- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Heat pump function C R410A -10 C bis +20 C -20 C bis +45 C Air-cooled Liquid Chillers Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring DN 80 Storz B up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 74 Power input kw 24,3 Voltage V/Hz/Phases 400/50/3 Operating current A 63 Electrical Connection Cable terminals - ** Fuse protection A 80 ** Cable recommendation mm 2 25 Flow rate m 3 /h 12,96 Technical description: Air cooled corrosion resistant chiller with heat pump version for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running scroll compressors. The fluid cooler has an integrated cold water pump head height of 11m (110kPa), it should be set up on a horizontal, stable work area and have at least 1m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 11 Cold water connections Storz B Capacity control Steps 2 Refrigerant R 410A Sound pressure at 5m db(a) 62 Transport weight kg ca Dimensions (l x w x h) mm 2870x1200x2400 * Design conditions: Evaporator water temperatures 12/7, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist. Control cabinet with electrical connections Cold water connection with Storz-plugs

23 ACR-M-80/P Technical Specifications - Rental Chiller Quick overview: Scroll- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Sound level +40 C 23 R410A -10 C bis +20 C -20 C low noise Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring Air-cooled Liquid Chillers DN 80 Storz B up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 84 Power input kw 25,3 Voltage V/Hz/Phases 400/50/3 Operating current A 75 Electrical Connection Cable terminals - ** Fuse protection A 80 ** Cable recommendation mm 2 25 Flow rate m 3 /h 14,4 Technical description: Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running scroll compressors. The fluid cooler has an integrated cold water pump head height of 9m (90kPa), it should be set up on a horizontal, stable work area and have at least 1m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 9 Cold water connections Storz B Capacity control Steps 2 Refrigerant R 410A Sound pressure at 5m db(a) 62 Transport weight kg 811 Dimensions (l x w x h) mm 2870x1200x2400 * Design conditions: Evaporator water temperatures 12/7, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist. Control cabinet with electrical connections Cold water connection with Storz-plugs

24 ACR-M-100/P Technical Specifications - Rental Chiller Quick overview: Scroll- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Sound level C R410A -10 C bis +20 C -20 C low noise Air-cooled Liquid Chillers Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring DN 80 Storz B up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 95 Power input kw 33 Voltage V/Hz/Phases 400/50/3 Operating current A 94 Electrical Connection Cable terminals - ** Fuse protection A 100 ** Cable recommendation mm 2 35 Flow rate m 3 /h 16,3 Technical description: Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running scroll compressors. The fluid cooler has an integrated cold water pump head height of 14m (140kPa), it should be set up on a horizontal, stable work area and have at least 1m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 14 Cold water connections Storz B Capacity control Steps 3 Refrigerant R 410A Sound pressure at 5m db(a) 62 Transport weight kg 878 Dimensions (l x w x h) mm 2870x1200x2400 * Design conditions: Evaporator water temperatures 12/7, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist. Control cabinet with electrical connections Cold water connection with Storz-plugs

25 ACR-M-130/P Technical Specifications - Rental Chiller Quick overview: Scroll- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Sound level +40 C 25 R410A -10 C bis +20 C -20 C low noise Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring Air-cooled Liquid Chillers DN 80 Storz B up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 128 Power input kw 42 Voltage V/Hz/Phases 400/50/3 Operating current A 95 Electrical Connection Cable terminals - ** Fuse protection A 100 ** Cable recommendation mm 2 35 Flow rate m 3 /h 22 Technical description: Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running scroll compressors. The fluid cooler has an integrated cold water pump head height of 6m (60kPa), it should be set up on a horizontal, stable work area and have at least 1m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 6 Cold water connections Storz A Capacity control Steps 3 Refrigerant R 410A Sound pressure at 5m db(a) 63 Transport weight kg Dimensions (l x w x h) mm 2900x1230x2450 * Design conditions: Evaporator water temperatures 12/7, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist. Control cabinet with electrical connections Cold water connection with Storz-plugs

26 ACR-M-150/P Technical Specifications - Rental Chiller Quick overview: Scroll- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Sound level C R410A -10 C bis +20 C -20 C low noise Air-cooled Liquid Chillers Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring DN 80 Storz B up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 147 Power input kw 48 Voltage V/Hz/Phases 400/50/3 Operating current A 124 Electrical Connection Cable terminals - ** Fuse protection A 160 ** Cable recommendation mm 2 70 Flow rate m 3 /h 25,6 Technical description: Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running scroll compressors. The fluid cooler has an integrated cold water pump head height of 12m (120kPa), it should be set up on a horizontal, stable work area and have at least 1m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 12 Cold water connections Storz A Capacity control Steps 4 Refrigerant R 410A Sound pressure at 5m db(a) 63 Transport weight kg ca Dimensions (l x w x h) mm 4050x1100x2320 * Design conditions: Evaporator water temperatures 12/7, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist. Control cabinet with electrical connections Cold water connection with Storz-plugs

27 ACR-M-180/P Technical Specifications - Rental Chiller Quick overview: Scroll- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Sound level +40 C 27 R410A -10 C bis +20 C -20 C low noise Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring Air-cooled Liquid Chillers DN 80 Storz B up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 171 Power input kw 60 Voltage V/Hz/Phases 400/50/3 Operating current A 152 Electrical Connection Cable terminals - ** Fuse protection A 160 ** Cable recommendation mm 2 70 Flow rate m 3 /h 29,2 Technical description: Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running scroll compressors. The fluid cooler has an integrated cold water pump head height of 5m (50kPa), it should be set up on a horizontal, stable work area and have at least 1m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 5 Cold water connections Storz A Capacity control Steps 4 Refrigerant R 410A Sound pressure at 5m db(a) 63 Transport weight kg Dimensions (l x w x h) mm 4080x1220x2400 * Design conditions: Evaporator water temperatures 12/7, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist. Control cabinet with electrical connections Cold water connection with Storz-plugs

28 ACR-M-255/P Technical Specifications - Rental Chiller Quick overview: Screw- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Sound level C R134a -15 C bis +20 C -20 C low noise Air-cooled Liquid Chillers Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring DN 100 Storz A up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 249 Power input kw 85 Voltage V/Hz/Phases 400/50/3 Operating current A 189 Electrical Connection Cable terminals - ** Fuse protection A 200 ** Cable recommendation mm 2 95 Flow rate m 3 /h 42,8 Technical description: Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with a very quiet running screw compressor. The fluid cooler has an integrated cold water pump head height of 11,5m (115kPa), it should be set up on a horizontal, stable work area and have at least 2m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 11,5 Cold water connections Storz A Capacity control % Refrigerant R 134a Sound pressure at 5m db(a) 65 Transport weight kg Dimensions (l x w x h) mm 3100x2300x2380 * Design conditions: Evaporator water temperatures 12/7, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist. Control cabinet with electrical connections Cold water connection with Storz-plugs

29 ACR-M-310/P Technical Specifications - Rental Chiller Quick overview: Screw- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Sound level +40 C 29 R134a -15 C bis +20 C -20 C low noise Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring Air-cooled Liquid Chillers DN 100 Storz A up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 306 Power input kw 105 Voltage V/Hz/Phases 400/50/3 Operating current A 240 Electrical Connection Cable terminals - ** Fuse protection A 250 ** Cable recommendation mm 2 95 (single-wire) Flow rate m 3 /h 52,7 Technical description: Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with a very quiet running screw compressor. The fluid cooler has an integrated cold water pump head height of 7m (70kPa), it should be set up on a horizontal, stable work area and have at least 2m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 7 Cold water connections Storz A Capacity control % Refrigerant R 134a Sound pressure at 5m db(a) 65 Transport weight kg Dimensions (l x w x h) mm 3100x2300x2380 * Design conditions: Evaporator water temperatures 12/7, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist. Control cabinet with electrical connections Cold water connection with Storz-plugs

30 ACR-M-370/P Technical Specifications - Rental Chiller Quick overview: Screw- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Sound level C R134a -15 C bis +20 C -20 C low noise Air-cooled Liquid Chillers Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring DN 100 Storz A up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 370 Power input kw 134 Voltage V/Hz/Phases 400/50/3 Operating current A 266 Electrical Connection Cable terminals - ** Fuse protection A 315 ** Cable recommendation mm (single-wire) Flow rate m 3 /h 63,7 Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running screw compressors. The fluid cooler has an integrated cold water pump head height of 7,5m (75kPa), it should be set up on a horizontal, stable work area and have at least 2m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 7,5 Cold water connections Storz A Capacity control % 12,5-100 Refrigerant R 134a Sound pressure at 5m db(a) 69 Transport weight kg Dimensions (l x w x h) mm 4200x2300x2580 * Design conditions: Evaporator water temperatures 12/7, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist. Control cabinet with electrical connections Cold water connection with Storz-plugs

31 ACR-M-420/P Technical Specifications - Rental Chiller Quick overview: Screw- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump +40 C 31 R134a -10 C bis +20 C -20 C Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring Air-cooled Liquid Chillers DN 100 Storz A up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 420 Power input kw 161 Voltage V/Hz/Phases 400/50/3 Operating current A 322 Electrical Connection Cable terminals - ** Fuse protection A 400 ** Cable recommendation mm (single-wire) Flow rate m 3 /h 72,4 Technical description: Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running screw compressors. The fluid cooler has an integrated cold water pump head height of 18,5m (185kPa), it should be set up on a horizontal, stable work area and have at least 2m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 18,5 Cold water connections Storz A Capacity control % 12,5-100 Refrigerant R 134a Sound pressure at 5m db(a) 67 Transport weight kg ca Dimensions (l x w x h) mm 4200x2330x2350 * Auslegungsbedingungen: Kaltwasser- Ein-/Austrittstemperatur 12/7, Außentemp. 32 C **Absicherung und Leitungsquerschnitte sind vom Electricfachbetrieb durch den Auftraggeber prüfen zu lassen Control cabinet with electrical connections Cold water connection with Storz-plugs

32 ACR-M-430/PP Technical Specifications - Rental Chiller Quick overview: Screw- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Sound level C R134a -10 C bis +20 C -20 C low noise Air-cooled Liquid Chillers Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring DN 100 Storz A up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 433 Power input kw 170 Voltage V/Hz/Phases 400/50/3 Operating current A 348 Electrical Connection Cable terminals - ** Fuse protection A 400 ** Cable recommendation mm (single-wire) Flow rate m 3 /h 74,5 Technical description: Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running screw compressors. The fluid cooler has an integrated cold water pump head height of 11m (110kPa), it should be set up on a horizontal, stable work area and have at least 2m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 11 Cold water connections Storz A Capacity control % 12,5-100 Refrigerant R 134a Sound pressure at 5m db(a) 63 Transport weight kg Dimensions (l x w x h) mm 4040x2240x2500 * Design conditions: Evaporator water temperatures 12/7, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist. Control cabinet with electrical connections Cold water connection with Storz-plugs

33 ACR-M-490/P Technical Specifications - Rental Chiller Quick overview: Screw- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Sound level +40 C 33 R134a -10 C bis +20 C -20 C low noise Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring Air-cooled Liquid Chillers DN 100 Storz A up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 492 Power input kw 177 Voltage V/Hz/Phases 400/50/3 Operating current A 368 Electrical Connection Cable terminals - ** Fuse protection A 400 ** Cable recommendation mm (single-wire) Flow rate m 3 /h 85 Technical description: Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running screw compressors. The fluid cooler has an integrated cold water pump head height of 16m (160kPa), it should be set up on a horizontal, stable work area and have at least 2m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 16 Cold water connections Storz A Capacity control % 12,5-100 Refrigerant R 134a Sound pressure at 5m db(a) 66 Transport weight kg Dimensions (l x w x h) mm 5250x2300x2650 * Auslegungsbedingungen: Kaltwasser- Ein-/Austrittstemperatur 12/7, Außentemp. 32 C **Absicherung und Leitungsquerschnitte sind vom Electricfachbetrieb durch den Auftraggeber prüfen zu lassen Control cabinet with electrical connections Cold water connection with Storz-plugs

34 ACR-M-500/P Technical Specifications - Rental Chiller Quick overview: Scroll- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Sound level C R407C -10 C bis +20 C -20 C low noise Air-cooled Liquid Chillers Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring DN 100 Storz A up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 506 Power input kw 181 Voltage V/Hz/Phases 400/50/3 Operating current A 406 Electrical Connection Aderendhülse 25mm ** Fuse protection A 500 ** Cable recommendation mm 2 2x120 (singlewire) Flow rate m 3 /h 86,8 Technical description: Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running scroll compressors. The fluid cooler has an integrated cold water pump head height of 14m (140kPa), it should be set up on a horizontal, stable work area and have at least 2m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 14 Cold water connections Storz A Capacity control Steps 12 Refrigerant R 407C Sound pressure at 5m db(a) 61 Transport weight kg * Design conditions: Evaporator water temperatures 12/7, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist. Control cabinet with electrical connections Cold water connection with Storz-plugs

35 ACR-M-550/P Technical Specifications - Rental Chiller Quick overview: Screw- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Sound level +40 C 35 R134a -10 C bis +20 C -20 C low noise Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring Air-cooled Liquid Chillers DN 100 Storz A up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 548 Power input kw 185 Voltage V/Hz/Phases 400/50/3 Operating current A 379 Electrical Connection Cable terminals - ** Fuse protection A 400 ** Cable recommendation mm (single-wire) Flow rate m 3 /h 95 Technical description: Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running screw compressors. The fluid cooler has an integrated cold water pump head height of 20m (200kPa), it should be set up on a horizontal, stable work area and have at least 2m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 20 Cold water connections Storz A Capacity control % 12,5-100 Refrigerant R 134a Sound pressure at 5m db(a) 69 Transport weight kg Dimensions (l x w x h) mm 4300x2300x2350 * Design conditions: Evaporator water temperatures 12/7, Ambient temperature 32 C **On-Site power installation should be entrusted to an electrical specialist. Control cabinet with electrical connections Cold water connection with Storz-plugs

36 ACR-M-608/PP Technical Specifications - Rental Chiller Quick overview: Screw- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Sound level C R134a -10 C bis +20 C -20 C low noise Air-cooled Liquid Chillers Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring DN 100 Storz A up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 613 Power input kw 200 Voltage V/Hz/Phases 400/50/3 Operating current A 393 Electrical Connection Cable terminals - ** Fuse protection A 400 ** Cable recommendation mm (single-wire) Flow rate m 3 /h 105,5 Technical description: Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running screw compressors. The fluid cooler has an integrated cold water twin-pump head height of 8,5m (85kPa), it should be set up on a horizontal, stable work area and have at least 2m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 8,5 Cold water connections Storz A Capacity control % 12,5-100 Refrigerant R 134a Sound pressure at 5m db(a) 66 Transport weight kg Dimensions (l x w x h) mm 5100x2350x2530 * Design conditions: Evaporator water temperatures 12/7, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist. Control cabinet with electrical connections Cold water connection with Storz-plugs

37 ACR-M-850/P Technical Specifications - Rental Chiller Quick overview: Screw- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump +40 C 37 R134a -10 C bis +20 C -20 C Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring Air-cooled Liquid Chillers DN 125 Storz 125 up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 832 Power input kw 299 Voltage V/Hz/Phases 400/50/3 Operating current A 589 Electrical Connection Cable terminals M16 ** Fuse protection A 630 ** Cable recommendation mm 2 7x150 (single-wire) Flow rate m 3 /h 142,92 Technical description: Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running screw compressors. The fluid cooler has an integrated cold water pump head height of 17,5m (175kPa), it should be set up on a horizontal, stable work area and have at least 2m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 17,5 Cold water connections Storz 125 Capacity control % 12,5-100 Refrigerant R 134a Sound pressure at 5m db(a) 72 Transport weight kg Dimensions (l x w x h) mm 6185x2285x2540 * Design conditions: Evaporator water temperatures 12/7, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist. Control cabinet with electrical connections

38 ACR-M-1080/P Technical Specifications - Rental Chiller Quick overview: Screw- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Sound level C R134a -10 C bis +20 C -20 C low noise Air-cooled Liquid Chillers Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring DN 125 Storz 125 up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 1074 Power input kw 338 Voltage V/Hz/Phases 400/50/3 Operating current A 731 Electrical Connection Cable terminals - ** Fuse protection A 2x400A ** Cable recommendation mm 2 7x185 (single-wire) Flow rate m 3 /h 184 Technical description: Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running screw compressors. The fluid cooler has an integrated cold water pump head height of 19m (190kPa), it should be set up on a horizontal, stable work area and have at least 2m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 19 Cold water connections Storz 125 Capacity control % 12,5-100 Refrigerant R 134a Sound pressure at 5m db(a) 69 Transport weight kg Dimensions (l x w x h) mm 8000x2285x2540 * Design conditions: Evaporator water temperatures 12/7, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist. Control cabinet with electrical connections

39 ACR-M-1175 Technical Specifications - Rental Chiller Quick overview: Screw- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump +40 C 39 R134a -10 C bis +20 C -20 C Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring Air-cooled Liquid Chillers DN 125 Storz 125 up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 1175 Power input kw 383 Voltage V/Hz/Phases 400/50/3 Operating current A 844 Electrical Connection Cable terminals - ** Fuse protection A 3x315A ** Cable recommendation mm 2 11x150(single-wire) Flow rate m 3 /h 184 Technical description: Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running screw compressors. The fluid cooler should be set up on a horizontal, stable work area and have at least 2m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m on request Cold water connections Storz 125 Capacity control % % Refrigerant R 134a Sound pressure at 5m db(a) 69 Transport weight kg Dimensions (l x w x h) mm 8000x2285x2540 * Design conditions: Evaporator water temperatures 12/7, Ambient temperature 32 C **On-Site power installation should be entrusted to an electrical specialist. Control cabinet with electrical connections

40 ACR-M-1420/P Technical Specifications - Rental Chiller Quick overview: Screw- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Sound level C R134a -10 C bis +20 C -20 C low noise Air-cooled Liquid Chillers Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring DN 125 Storz 125 up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 1418 Power input kw 474 Voltage V/Hz/Phases 400/50/3 Operating current A 974 Electrical Connection Cable terminals - ** Fuse protection A 2x 500 ** Cable recommendation mm 2 11x185(single-wire) Flow rate m 3 /h 243 Technical description: Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running screw compressors. The fluid cooler has an integrated cold water pump head height of 20m (200kPa), it should be set up on a horizontal, stable work area and have at least 2m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 20 Cold water connections Storz 125 Capacity control % 12,5-100 Refrigerant R 134a Sound pressure at 5m db(a) 69 Transport weight kg Dimensions (l x w x h) mm 8885x2285x2540 * Design conditions: Evaporator water temperatures 12/7, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist. Control cabinet with electrical connections

41 ACR-M-2000/P Technical Specifications - Rental Chiller Quick overview: Screw- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Sound level +40 C 41 R134a -15 C bis +20 C -20 C low noise Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring Air-cooled Liquid Chillers DN 125 Storz 125 up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 2008 Power input kw 672 Voltage V/Hz/Phases 400/50/3 Operating current A 1473 Electrical Connection Cable terminals - ** Fuse protection A 3x500 ** Cable recommendation mm 2 14x185 Flow rate m 3 /h 345 Technical description: Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running screw compressors. The fluid cooler should be set up on a horizontal, stable work area and have at least 2m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 Cold water connections Storz 2x DN125 Capacity control % 12,5-100 Refrigerant R 134a Sound pressure at 5m db(a) 70 Transport weight kg Dimensions (l x w x h) mm 14700x2285x2540 * Design conditions: Evaporator water temperatures 12/7, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist. Control cabinet with electrical connections

42

43 Water-Cooled Liquid Chillers 43 Water-Cooled Liquid Chillers Chillers for installation in dry and frost-free environments. With a capacity of 200 kw to 1,000 kw per cooler, fluids can be cooled in the temperature range between plus 25 C (can also be higher in conjunction with plate heat exchangers) and -15 C. Optionally the acr drycoolers can be configured to provide free cooling. Cooling (heat dissipation of the condenser heat) is achieved via an existing cooling system, or alternatively through an acr rental wet or drycooler. The liquid-cooled acr rental fluid chillers can be applied in all areas where liquids are to be cooled. The areas of application are manifold: For example, the units are used in building air-conditioning, production processes, test setups, medical technology, pharmaceuticals, food processing, beverage industry, chemical industry, plastics industry, and in many other areas. The installation and integration is very simple: The water-cooled liquid chillers in the acr rental park are designed for installation in a dry, frost-free location and can be installed on any suitable ground. After connecting the pre-configured flexible cold and coolant hoses and the power cabling the mobile refrigeration unit can go into operation.

44 ACR-M-100-W Technical Specifications - Rental Chiller Quick overview: Scroll- Compressor Refrigerant Processtemperature Ambienttemperature Sound level C R410A -10 C bis +20 C +5 C low noise Water-Cooled Liquid Chillers Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Cooling tower/ Dry cooler Electrical cables DN 80 Storz B up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 94 Power input kw 22 Voltage V/Hz/Phases 400/50/3 Operating current A 62 Electrical Connection Wire end sleeves - ** Fuse protection A 80 ** Cable recommendation mm 2 25 Flow rate Verd. m 3 /h 16,2 Technical description: The water-cooled fluid chillers for mechanical cold water - / fluid cooling, are equipped with two quiet running scroll compressors. The plate evaporator and the plate condenser consist of stainless steel. The unit should be set up on a horizontal, stable work area and have at least 2m free space to all sides. All controls and regulators are contained within the housing. Flow rate Verfl. m 3 /h 16,9 Maximum operating pressure bar 10 Cold water connections Storz B Kühlwasser-Anschlüsse Storz C Capacity control Steps 2 Refrigerant R 410A Sound pressure at 5m db(a) 50 Transport weight kg 460 Dimensions (l x w x h) mm 1800x710x1830 * Design conditions: Evaporator water temperatures 12/7 Cooling water temperatures 29/35 C **On-Site power installation should be entrusted to an electrical specialist.

45 ACR-M-200-W Technical Specifications - Rental Chiller Quick overview: Scroll- Compressor Refrigerant Processtemperature Ambienttemperature Sound level +40 C 45 R407C -10 C bis +20 C +5 C low noise Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Cooling tower/ Dry cooler Electrical cables Water-Cooled Liquid Chillers DN 100 Storz A up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 247 Power input kw 60 Voltage V/Hz/Phases 400/50/3 Operating current A 170 Electrical Connection Wire end sleeves - ** Fuse protection A 200 ** Cable recommendation mm 2 95 Flow rate Verd. m 3 /h 37,8 Technical description: The water-cooled fluid chillers for mechanical cold water - / fluid cooling, are equipped with quiet running scroll compressors. The plate evaporator and the plate condenser consist of stainless steel. The unit should be set up on a horizontal, stable work area and have at least 2m free space to all sides. All controls and regulators are contained within the housing. Flow rate Verfl. m 3 /h 39,6 Maximum operating pressure bar 10 Cold water connections Storz A Cooling water connections Storz A Capacity control Steps 4 Refrigerant R 407C Sound pressure at 5m db(a) 68 Transport weight kg 1100 Dimensions (l x w x h) mm 2200x700x1800 * Design conditions: Evaporator water temperatures 12/7 Cooling water temperatures 29/35 C **On-Site power installation should be entrusted to an electrical specialist.

46 ACR-M-900-W Technical Specifications - Rental Chiller Quick overview: Screw- Compressor Refrigerant Processtemperature Ambienttemperature C R410A -10 C bis +20 C +5 C Water-Cooled Liquid Chillers Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Cooling tower/ Dry Cooler Electrical cables DN 100 Storz A up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 858 Power input kw 175 Voltage V/Hz/Phases 400/50/3 Operating current A 504 Electrical Connection Cable terminals - ** Fuse protection A 630 ** Cable recommendation mm 2 2x150 (single-wire) Flow rate Verd. m 3 /h 123 Technical description: The water-cooled fluid chillers for mechanical cold water - / fluid cooling, are equipped with two quiet running screw compressors. The shell and tube evaporator and condenser are enclosed by a steel shell. The unit should be set up on a horizontal, stable work area and have at least 2m free space to all sides. All controls and regulators are contained within the housing. Flow rate Verfl. m 3 /h 104 Maximum operating pressure bar 10 Cold water connections Flange DN 125 Cooling water connections Flange DN125 Capacity control % Refrigerant R 134a Sound pressure at 5m db(a) 72 Transport weight kg 4000 Dimensions (l x w x h) mm 4200x1400x2200 * Design conditions: Evaporator water temperatures 12/7 Cooling water temperatures 29/35 C **On-Site power installation should be entrusted to an electrical specialist.

47 Mobile large scale refrigeration system 47 Mobile large scale refrigeration system The investment and cost-saving response to ever changing extreme demands placed on refrigeration technology is our weatherproof mobile units. They are available for different capacity levels, with or without a heat pump, hydraulic switches, plate heat exchanger, mixing and switching valves, cooling towers, drycooler, cooling device for free cooling, control technology, remote monitoring, and can be delivered by acr ready for operation. The high level of flexibility makes possible the reduction or increase of capacity as needed during the term of the lease. The mobile acr rental chillers can be applied in all areas where liquids are to be cooled and/or heated. The areas of application are manifold: For example, the units are used in building air-conditioning, production processes, test setups, medical technology, pharmaceuticals, food processing, beverage industry, chemical industry, plastics industry, and in many other areas. The installation and integration is very simple: The mobile chillers in the acr rental park are designed for outdoor installation and can be installed on any viable ground. After connecting the pre-configured flexible hoses on the cold water circuit and in some cases on the coolant circuit, as well as the power cabling, the mobile refrigeration unit can go into operation.

48 ACR-MKZ-4500 Technical Specifications - Large scale refrigeration system Quick overview: Centrifugal Compressor Refrigerant Processtemperature Ambienttemperature C Mobile large scale refrigeration system Optionally accessories: Pump modules R134a Heat exchanger ±0 C bis +15 C Buffer storage +5 C Cooling tower/ Dry Cooler Electrical cables up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 4500 Power input kw 680 Voltage V/Hz/Phases 400/50/3 Operating current A 1042 Starting current A 2090 Electrical Connection Cable terminals - ** Fuse protection A 3x400 Technical description: Water-cooled chillers in container style to be installed outdoors that are corrosion resistant. The unit provides mechanical cold water -/ fluid cooling and is equipped with a high-performance Centrifugal compressor. The shell and tube evaporator, copper / steel flooded type. The housing for all controls and regulators are integrated within the container. Extensive optional accessories are available. ** Cable recommendation mm 2 3x185 (single-wire) Flow rate Verd. m 3 /h ca. 970 Flow rate Verfl. m 3 /h ca Maximum operating pressure bar 10 Cold water connections DN 350 Kühlwasser-Anschlüsse DN 300 Capacity control % Refrigerant R 134a Transport weight kg Dimensions (l x w x h) mm 9000x3500x3500 * Design conditions: Evaporator water temperatures 12/6 Cooling water temperatures 26/33 C **On-Site power installation should be entrusted to an electrical specialist.

49

50 50 Low temperature units Low temperature units Condenser units (down to -40 C) Page 51 Air-cooled Liquid Chillers (down to -15 C) Page 53 Water-cooled Liquid Chillers (down to -45 C) Page 57

51 Condenser units (down to -40 C) 51 Condenser units down to -40 C Air cooled condenser units in Split design, for connection to existing, external vaporizers to produce extremely low temperatures down to minus 40 C. The units are equipped with an extremely rugged and smooth-running screw compressor. High performance numbers and low operating costs characterize the equipment. The mobile acr condenser units can be applied in all areas where extreme cooling of liquids is necessary. The areas of application are manifold: For example, the units are used in production processes, test setups, in the automotive industry, medical technology, pharmaceuticals, food processing, chemical industry, and in many other areas. The installation and integration is very simple: The mobile extreme low temperature chillers in the acr rental park are designed for outdoor installation and can be installed on any viable ground. After connection of the refrigerant lines as well as the power supply, the mobile unit can be put into operation.

52 ACR-VE-125 Technical Specifications - Rental Condenser unit up to -40 C Quick overview: Screw- Compressor Refrigerant Processtemperature Ambienttemperature Sound level C R507A bis -40 C -20 C low noise Condenser units down to -40 C Optionally accessories: Evaporator/ air distribution Electrical cables Remote monitoring Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 125 Power input kw 102 Voltage V/Hz/Phases 400/50/3 Operating current A ca. 214 Starting current A ca. 642 Electrical Connection Cable terminals - ** Fuse protection A 250 ** Cable recommendation mm 2 95 (single-wire) Capacity control % Refrigerant R 507A Sound pressure at 5m db(a) 69 Transport weight kg Dimensions (l x w x h) mm 5000x2300x2400 Technical description: Air cooled corrosion resistant condenser units in split design for outdoor locations. The unit is suitable for the connection to existing, external vaporizers. The condenser units work with screw compressors and have a step less variable power adjustment between % as well as a microprocessor driven regulation. The unit should be set up on a horizontal, stable work area and have at least 2m free space to all sides. All controls and regulators are contained within the housing. * Design conditions: Evaporating temperature -40 C, Ambient Temperature 32 C **On-Site power installation should be entrusted to an electrical specialist.

53 Air-cooled Liquid Chillers (down to -15 C) 53 Air-cooled Liquid Chillers down to -15 C The especially compact air cooled fluid coolers are ideal for set up in the outdoors. With a capacity of up to 1,000 kw per unit, at a brine temperature down to minus 15 C, all conditions and scopes can be covered. Different power levels with or without hydraulic switches, plate heat exchangers, mixing and switching valves, regulation technology, remote monitoring, respectively as a ready to use fluid cooler of acr. The mobile acr rental units can be applied in all areas where liquids are to be cooled. The areas of application are manifold: For example, the units are used in production processes, test setups, in the automotive industry, medical technology, pharmaceuticals, food processing, chemical industry, and in many other areas. The installation and integration is very simple: The mobile chillers in the acr rental park are designed for outdoor installation and can be installed on any viable ground. After connecting the hoses on the cold water circuit and in some cases on the coolant circuit, as well as the power cabling, the mobile refrigeration unit can go into operation.

54 ACR-TK-100 Technical Specifications - Rental Chiller up to -15 C Quick overview: Screw- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Sound level C Air-cooled Liquid Chillers down to -15 C Optionally accessories: Cold water tubes R134a Pump modules -15 C bis +20 C Heat exchanger -20 C Buffer storage Electrical cables low noise Remote monitoring DN 100 Storz A bis 60m Förderhöhe Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 91 Power input kw 58 Voltage V/Hz/Phases 400/50/3 Operating current A 189 Electrical Connection Cable terminals - ** Fuse protection A 250 ** Cable recommendation mm 2 95 (single-wire) Flow rate m 3 /h 18 Technical description: Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running screw compressors. The fluid cooler has an integrated cold water pump head height of 21m (210kPa), it should be set up on a horizontal, stable work area and have at least 2m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 21 Cold water connections Storz A Capacity control % Refrigerant R 134a Sound pressure at 5m db(a) 65 Transport weight kg Dimensions (l x w x h) mm 3100x2300x2380 * Design conditions: Evaporator brine temperatures -10/-15, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist. Control cabinet with electrical connections Brine connection with Storz-plugs

55 ACR-TK-200/P Technical Specifications - Rental Chiller up to -15 C Quick overview: Screw- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Sound level +40 C 55 Optionally accessories: Cold water tubes R134a Pump modules -15 C bis +20 C Heat exchanger -20 C Buffer storage Electrical cables low noise Remote monitoring Air-cooled Liquid Chillers down to -15 C DN 100 Storz A bis 60m Förderhöhe Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 203 Power input kw 135 Voltage V/Hz/Phases 400/50/3 Operating current A 348 Electrical Connection Cable terminals - ** Fuse protection A 400 ** Cable recommendation mm (single-wire) Flow rate m 3 /h 40,3 Technical description: Air cooled corrosion resistant chiller for outdoor locations. This mechanical refrigeration unit for providing cold water is equipped with very quiet running screw compressors. The fluid cooler has an integrated cold water pump head height of 15m (150kPa), it should be set up on a horizontal, stable work area and have at least 2m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 15 Cold water connections Storz A Capacity control % 12,5-100 Refrigerant R 134a Sound pressure at 5m db(a) 67 Transport weight kg Dimensions (l x w x h) mm 4100x2300x2580 * Design conditions: Evaporator brine temperatures -10/-15, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist. Control cabinet with electrical connections Brine connection with Storz-plugs

56

57 Water-cooled Liquid Chillers (down to -45 C) 57 Water-cooled Liquid Chillers down to -45 C For the generation of extremely low temperatures, down to minus 45 C. The units are equipped with an extremely rugged and smooth-running screw compressor. High performance numbers and low operating costs characterize the equipment which is installed in a weatherproof container. Different power levels with or without hydraulic switches, plate heat exchangers, mixing and switching valves, cooling tower, drycooler, regulation and control technology, remote monitoring, installed by acr as a ready to operate extreme low temperature refrigeration central. The high level of flexibility makes possible the reduction or increase of capacity as needed during the term of the lease. The mobile acr extreme low temperature refrigeration units can be applied in all areas where extreme cooling of liquids is necessary. The areas of application are manifold: For example, the units are used in production processes, test setups, in the automotive industry, medical technology, pharmaceuticals, food processing, chemical industry, and in many other areas. The installation and integration is very simple: The mobile extreme low temperature chillers in the acr rental park are designed for outdoor installation and can be installed on any viable ground. After connecting the hoses on the cold water circuit and in some cases on the coolant circuit, as well as the power cabling, the mobile refrigeration unit can go into operation.

58 ACR-TT2-320 Technical Specifications - Low temperature chiller Quick overview: Screw- Compressor Refrigerant Processtemperature Ambienttemperature Titaniumevaporator C Water-cooled Liquid Chillers down to -45 C Optionally accessories: Pump modules (Lift) R507A Heat exchanger bis -45 C Buffer storage -20 C Electrical cables Cooling tower/ Dry Cooler Remote monitoring up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 320 Power Input (Compressor) kw 310 Voltage V/Hz/Phases 400/50/3 Operating current A 502 Electrical Connection Cable terminals - ** Fuse protection A 630 ** Cable recommendation mm 2 2 x 120 (single-wire) Flow rate evaporator m 3 /h 87 Technical description: Corrosion resistant, water cooled brine chiller for outdoor locations. The unit is used for mechanical brine cooling to -24 C at the evaporator outlet. Consists of the following main components: Screw compressor, oil precipitator, oil cooler, Economizer; titanium vaporizer, ccondenser, electrical cabinet for all controls and regulation. Housing cooling and floor pan according to WHG. Extensive optional accessories are available. Flow rate condenser m 3 /h 48 Maximum operating pressure bar 10 Cold water connections Flange DN 125 Kühlwasser-Anschlüsse Flange DN 125 Capacity control % Refrigerant R 507A Transport weight kg Dimensions (l x w x h) mm 5500x2500x2700 * Design conditions: Evaporator brine temperatures -20/-24 (Brine: CaCl 2 /H 2 O 28/72%) Cooling water temperatures 25/30 **On-Site power installation should be entrusted to an electrical specialist.

59 ACR-TT3-400 Technical Specifications - Low temperature chiller Quick overview: Screw- Compressor Refrigerant Processtemperature Ambienttemperature +40 C 59 Optionally accessories: Pump modules R507A Heat exchanger bis -45 C Buffer storage -20 C Electrical cables Cooling tower/ Dry Cooler Remote monitoring Water-cooled Liquid Chillers down to -45 C up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity (bei -40 C) kw 219 Power Input (Compressor) kw 242 Voltage V/Hz/Phases 400/50/3 Operating current A 648 Electrical Connection Cable terminals - ** Fuse protection A 2x 400 ** Cable recommendation mm 2 2x 185 (single-wire) Flow rate evaporator m 3 /h 106 Technical description: Corrosion resistant, water cooled brine chiller for outdoor locations. The unit is used for mechanical brine cooling to -45 C at the evaporator outlet. Consists of the following main components: Screw compressor, oil precipitator, oil cooler, Economizer; shell and tube vaporizer and condenser, electrical cabinet for all controls and regulation. Housing cooling and floor pan according to WHG. Extensive optional accessories are available. Flow rate condenser m 3 /h 78 Maximum operating pressure bar 10 Capacity control % Refrigerant R 507A Transport weight kg Dimensions (l x w x h) mm 6700x2550x2700 * Design conditions: Evaporator brine temperatures -35/-40 (Brine: THERMINOL D12) Cooling water temperatures 30/35 **On-Site power installation should be entrusted to an electrical specialist.

60 60 Drycooler Drycooler Drycooler Page 61 Wetcooler Page 65

61 Drycooler 61 Drycooler A stable and corrosion-resistant design for outdoor installation with reliable and quiet running axial fans. An optimized heat exchanger in the Cu-Al version ensures maximum efficiency values. The acr drycooler can be used for watercooled liquid chillers as a free cooling unit, or for direct free cooling of fluids between plus 120 C and plus 5 C by means of ambient air. The units have an integrated control cabinet. A temperature sensor on the medium-outlet side regulates the medium temperature. At higher temperatures, and for special material requirements, these coolers can be combined with acr plate heat exchangers for system separation. The acr drycoolers can be used for cooling of existing or rented water-cooled liquid chillers. Another application is the direct cooling of liquids by means of ambient air as a free cooling unit. The areas of application are manifold: For example, the units are used in building air-conditioning, production processes, test setups, medical technology, pharmaceuticals, food processing, beverage industry, chemical industry, plastics industry, and in many other areas. The installation and integration is very simple: The mobile drycoolers in the acr rental park are designed for outdoor installation and can be installed on any viable ground. After connecting the pre-configured flexible hoses and the power cabling the cooler can go into operation.

62 ACR-RK-215 Technical Specifications - Rental cooler Quick overview: Processtemperature Ambienttemperature Sound level C ±0 C bis +120 C -20 C low noise Drycooler Optionally accessories: Cold water tubes Pump modules Heat exchanger Electrical cables Remote monitoring DN 100 Storz A up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: Recooling Free cooling *Recooling capacity kw Power input ventilator kw 0,6 Voltage V/Hz/Phases 230/50/1 Operating current A 2,6 Electrical Connection Wire end sleeves - ** Fuse protection A 16 ** Cable recommendation mm 2 2,5 Ethylene glycol % 34 Air inlet C Medium inlet C Medium outlet C Medium inlet connection Flansch DN 80 Medium outlet connection Flansch DN 80 Pressure drop kpa 4 Flow rate m 3 /h 10,1 Sound pressure at 5m db(a) 51 Transport weight kg 400 Dimensions (l x w x h) mm 3800x1200x800 Technical description: Air-cooled table cooler consisting of axial fans, and a heat exchanger in Cu / aluminium. The unit is used for cooling of excess, process or condenser heat. The air inlet is from bottom and the heated air is blown upward. This design insures an optimum as well as economical heat exchange. Due to the closed cooling circuit its contamination is impossible. Solid construction with attached control cabinet. Extensive optional accessories are available. **On-Site power installation should be entrusted to an electrical specialist.

63 ACR-RK-342 Technical Specifications - Rental cooler Quick overview: Processtemperature Ambienttemperature Sound level +40 C 63 ±0 C bis +120 C -20 C low noise Optionally accessories: Cold water tubes Pump modules Heat exchanger Electrical cables Remote monitoring Drycooler DN 100 Storz A up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: Recooling Free cooling *Recooling capacity kw Power input ventilator kw 14 Voltage V/Hz/Phases 400/50/3 Operating current A 27 Electrical Connection Wire end sleeves - ** Fuse protection A 35 ** Cable recommendation mm 2 6 Ethylene glycol % 34 Air inlet C 32 4 Medium inlet C Medium outlet C Medium inlet connection DN 80 Medium outlet connection DN 80 Pressure drop kpa 52 Flow rate m 3 /h 84 Sound pressure at 5m db(a) 66 Transport weight kg 1700 Dimensions (l x w x h) mm 8300x2400x1500 Technical description: Air-cooled table cooler consisting of axial fans, and a heat exchanger in Cu / aluminium. The unit is used for cooling of excess, process or condenser heat. The air inlet is from bottom and the heated air is blown upward. This design insures an optimum as well as economical heat exchange. Due to the closed cooling circuit its contamination is impossible. Solid construction with attached control cabinet. Extensive optional accessories are available. **On-Site power installation should be entrusted to an electrical specialist.

64

65 Wetcooler 65 Wetcooler A stable and corrosion-resistant open evaporation cooler designed for outdoor installation with reliable and quiet running radial fans. The unit is used for cooling of excess, process or condenser heat. The acr wetcoolers can be used for water-cooled liquid chillers as a free cooling unit, or for direct cooling of fluids between plus 60 C and plus 6 C. Due to the surrounding air and evaporating water, cool water temperatures are reached, which are well below the air temperature. The units have as an option an integrated control cabinet. A temperature sensor on the medium-outlet side regulates the medium temperature. At higher temperatures, and for special material requirements, these coolers can be combined with acr plate heat exchangers for system separation. The acr wetcoolers can be used for cooling of existing or rental water-cooled liquid chillers. Another application is the direct cooling of liquids by means of ambient air as a free cooling unit. By way of its modular design, the capacity can be increased by concatenation of multiple devices. The areas of application are manifold: For example, the units are used in building air-conditioning, production processes, test setups, medical technology, pharmaceuticals, food processing, beverage industry, chemical industry, plastics industry, and in many other areas. The installation and integration is very simple: The compact high capacity mobile wetcoolers in the acr rental park have been designed for outdoor installation and can be installed on any viable ground. After connecting the pre-configured flexible hoses and the power cabling the cooler can go into operation.

66 ACR-KT-1100 Technical Specifications - Rental cooling tower Quick overview: Processtemperature Ambienttemperature Sound level C bis +60 C +40 C -20 C low noise Wetcooler Optionally accessories: Cold water tubes Pump modules Electrical cables Remote monitoring up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Recooling capacity kw 1100 Power input kw 58 Voltage V/Hz/Phases 400/50/3 Operating current A 42 Starting current (FU) A 50 Electrical Connection Cable terminals - ** Fuse protection A 50 ** Cable recommendation mm 2 10 Wet bulb temperature C 22 Technical description: Open evaporation cooler with induced draft radial fans. The unit is used for cooling of excess, process or condenser heat. Air intake is at the front, and air exhaust is above. The cooling tower is executed in a modular design and can be extended by several equipment modules. For example, 3 modules = 3300kW cooling capacity. Extensive optional accessories are available. Please speak to us! Flow rate m 3 /h 158 Pressure drop at nozzles kpa 50 Volume of evaporated water m 3 /h 1,64 Rinse water amount m 3 /h 1,64 Water inlet DN 125 Water outlet DN 2x125 Drain Zoll 2 Replenishment Zoll 2 Overflow Zoll 2 Sound pressure at 5m db(a) 71 Transport weight kg 1700 * Design conditions: Cooling water temperatures 33/27, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist.

67

68 68 Air-conditioners/ Ventilation systems Air-conditioners / Ventilation systems Air-conditioners 69 Air handling unit 71 Air conditioning cabinets 75 Rooftops / Ventilation systems 77 Humidification 83

69 Air-conditioners 69 Air-conditioners Cooling and dehumidification through a mobile air-conditioner in a highly comfortable way: When rooms are very hot and rigorous cooling is required, then the strengths of these air conditioners become fully apparent. According to the capacity requirements, the mobile air-conditioner is as a compact air tube climate device or available as a water impinged Split design. The Split air conditioner expressly produced by acr ideally are suited for the offices, Event- or server air-conditioning. The especially quiet interior unit as well as a cooling capacity of up to 9kW per unit are here an exclusive feature of acr. The acr air conditioning / dehumidifying units can be applied in all areas where air is to be cooled or dehumidified. The areas of application are manifold: For example, the units are used in offices, sales and computer rooms, doctors' offices, museums, galleries, exhibitions and in many other areas. The installation and integration is very simple: The compact high capacity mobile air conditioners in the acr rental park have been designed for installation in dry and frost-free locations and can be installed on any viable ground. After connecting the power cabling the air conditioner can go into operation.

70 ACR-Split-9 Technical Specifications - Rental air conditioner Quick overview: Rotation- Compressor Refrigerant Air distribution Indoor unit Coolingtemperature Ambienttemperature C Air-conditioners/ Ventilation systems Sound level low noise R410A Cold water tubes Electrical cables +15 C bis +25 C +5 C Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 9,1 Power input kw 2,4 Voltage V/Hz/Phases 230/50/1 Operating current A 13 Electrical Connection Three-Pin-Plug - Flow rate m 3 /h 1,44 Cold water connections Storz C Capacity control % Refrigerant R 410A Soundpressure outdoor unit db(a) 48 at 5m Soundpressure indoor unit db(a) 44 at 5m Transport weight outdoor unit kg 110 Transport weight indoor unit kg 43 Dim. outdoor unit (l x w x h) mm 870x320x1100 Dim. indoor (l x w x h) mm 1430x570x275 Technical description: Mobile air-conditioner consisting of a water chiller as an outside unit and a water impinged ventilation device as an interior unit. The chiller is set up outdoors and is connected with previously filled cold water tubes with the interior device. The noisy and heavy unit with the refrigeration compressor is installed outdoors, and the quiet and easy to ventilate device is installed indoors. The capacity extends up to 9kW per unit and the device can be used to cool as well as heat. Further characteristics: - Simple commissioning - High mobility through the use of steering rollers - Tube length between interior and outside unit 30m - Quieter interior unit - Ready to plug in * Design conditions: Evaporator water temperatures 12/7, Ambient temperature 35 C **On-Site power installation should be entrusted to an electrical specialist.

71 Air handling unit 71 Air handling unit The air handling unit be operated with a acr rental liquid chiller or can be connected to the existing chilled water system. Depending on the requirements the air handling unit can be equipped with an elegant housing. The cooler has an integrated control unit and a drain pan under the heat exchanger so that the condensate can be selectively discharged when dehumidifying. Thanks to their compact size and light weight, the rental units can be easily transported and can be targeted to those situations where cooling is required. The acr air handling units can be applied in all areas where air is to be cooled or heated. The areas of application are manifold: For example, the units are used in building air-conditioning, event and tent cooling, production processes, test setups, medical technology, pharmaceuticals, food processing, beverage industry, chemical industry, plastics industry, and in many other areas. The installation and integration is very simple! The compact high capacity mobile air handling units in the acr rental park have been designed for dry and frost-free locations and can be installed in ceilings as well as on the ground. After connecting the pre-configured flexible hoses and the power cabling the air handling unit can go into operation.

72 ACR-F Technical Specifications - Rental air handler 72 Air handling unit Technical description: Air handling unit with radial ventilator for installation to the external cold water network or acr cold water producer. Installation indoors and a housing out of varnished sheet metal, and a sound isolated interior. Heat exchangers of Cu pipe with pressed aluminium fins. A condensate pan with a natural discharge flow is located under the heat exchanger. An air filter is attached to the air intake. All controls including 3 preselected fan speeds are integrated into the housing and are easy to use. Extensive optional accessories are available. Technical specifications: *Cooling capacity kw 3,6 6,1 10,1 **Heating capacity kw 4,4 5,9 10,6 Power input W Operating current A 0,8 1 1,8 Max. airflow volume m 3 /h Cold water connections Storz C C C Water rate l/h Water pressure drop kpa Sound pressure at 5m db(a) Transport weight kg * Design conditions: Cold water temperatures 12/7 ** Design conditions: Heating water temperatures 70/60 Dimensions: Length mm Width mm Height mm

73 ACR-F Technical Specifications - Rental air handler Technical description: Air handling unit with radial ventilator for installation to the external cold water network or acr cold water producer. Installation indoors and suitable for connection to the air ducts or textile air tubes. A 2-way thermostatic valve and temperature sensor, and a condensate water connection is present. A small control box is included, which assumes control of the valve and allows the ventilator to be switched on and off. A potential-free collective fault alert can be accessed. Extensive optional accessories are available. 73 Air handling unit Technical specifications: *Cooling capacity kw 21,4 35,9 46,2 *Sensitive cooling capacity kw 16,8 27,7 34,6 **Heating capacity kw 46,9 77,7 96,4 Power input kw 0,8 2,6 3,3 Operating current A 3,7 9,1 11,6 Max. airflow volume m 3 /h Cold water connections Storz C C C Sound pressure at 5m db(a) Transport weight kg * Design conditions: Cold water temperatures 12/7 ** Design conditions: Heating water temperatures 70/60 Dimensions: Length mm Width mm Height mm

74 ACR-FW Technical Specifications - Rental air handler with wide throwing nozzle 74 Air handling unit Technical description: High performance wide throwing nozzle air handler for connecting with the existing chilled water system or an acr chiller. Installation in storageor production halls, where it is necessary to cover large areas with a minimum of air handling units. Extensive optional accessories are available. Technical specifications: *Cooling capacity kw Kondensat kg/h Power input kw 1,1 1,9 Operating current A 2,2 3,5 Max. airflow volume m 3 /h Throw distance m Cold water connections Storz C C Water flow rate m 3 /h 8 37 Pressure drop kpa Sound pressure at 5m db(a) Transport weight kg ca. 250 ca. 800 * Design conditions: Cold water temperatures 12/7 and 25 C ambient temperature Dimensions: Length mm Width mm Height mm

75 Air conditioning cabinets 75 Air conditioning cabinets The space saving air conditioning cabinets are used with an acr rental liquid chiller or can be connected to the existing chilled water system. The air conditioning cabinets are fitted with a stylish enclosure and are available with the air intake from the front and discharge to the top or air intake from the top and discharge to the false floor. Thanks to their compact size and light weight, the rental units can be easily transported and can be targeted to those situations where cooling is required. The acr air conditioning cabinets can be applied in all areas where air is to be cooled or heated. The areas of application are manifold: For example, the units are used in computer and data centers, food processing, beverage industry, production processes, test setups, environmental simulations, automotive industry, medical technology, pharmaceuticals, chemical industry, and in many other areas. The installation and integration is very simple! The compact high capacity mobile air conditioning cabinets in the acr rental park have been designed for dry and frost-free locations. After connecting the pre-configured flexible hoses and the power cabling the air conditioning cabinets can go into operation.

76 ACR-KS Technical Specifications - Rental air conditioning cabinets 76 Air conditioning cabinets Technical description: Air conditioning cabinet for installation to the external cold water network or acr cold water producer. Air conditioning cabinets pre-painted galvanized sheet metal with stainless steel screws. Interior lining material is heat resistant and soundproof. Centrifugal blower with direct drive, both sided intake, statically and dynamically balanced. Air filters are made of filter class EU4 recyclable synthetic material. The electrical control cabinet with its user-friendly control unit is integrated in the air conditioning cabinet. Extensive optional accessories are available, such as straight and three way valves, supply air plenum, high capacity fan motors, humidifiers and more. Technical specifications: *Cooling capacity kw 22 40,7 74,2 Power input kw 0,55 1,10 2,20 Voltage V Operating current A 5,1 3,30 6,60 Max. airflow volume m 3 /h External static pressure Pa Cold water connections Storz C C C Sound pressure at 5m db(a) Electric damper register kw Transport weight kg * Design conditions: Cold water temperatures 12/7 27 C dry bulb temperature / 19 C wet bulb temperature Dimensions: Length mm Width mm Height mm

77 Rooftops / Ventilation systems 77 Rooftops / Ventilation systems Always produce the desired room temperature between plus 3 C and 30 C: The units are designed for outdoor operation and can be immediately operational, cool the air directly without an intervening medium. The air is distributed by means of powerful centrifugal fans. The condenser waste heat is discharged by means of an axial ventilator to the ambient air. Optionally, the units can be used as cooling or heating heat pumps in fresh, mixed and recirculation modes. The acr air handling units can be used in all areas where it is necessary to ensure that the correct temperature is maintained. The areas of application are manifold: For example, the units are used for events, tent air-conditioning, computer and data centers, food processing, beverage industry, production processes, test setups, environmental simulations, automotive industry, medical technology, pharmaceuticals, chemical industry, and in many other areas. The installation and integration is very simple: The mobile air handling units in the acr rental park are designed for outdoor installation and can be installed on any viable ground. After connecting the pre-configured flexible air hoses and the power cabling the mobile air handling unit can go into operation.

78 ACR-RT-60 Technical Specifications - Rental Rooftop units Quick overview: Scroll- Compressor Refrigerant Coolingtemperature Ambienttemperature Heatingtemperature Sound level C Rooftops / Ventilation systems Optionally accessories: Air transport R407C Air distribution +15 C bis +25 C Electrical cables +15 C bis +25 C Remote monitoring +5 C low noise luftdichter Schlauch luftdurchlässiger Schlauch Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 56 **Heating capacity kw 67 Power input - Cooling kw 26 Power input - Heating kw 26 max. operating current - Cooling A ca. 52 max. operating current - Heating A ca. 51 Electrical Connection CEE 63A *** Fuse protection A 63 *** Cable recommendation mm 2 16 Air flow volume m 3 /h External static pressure Pa 196 Capacity control Steps 2 Refrigerant circuits No. 2 Refrigerant R 407C Sound pressure at 5m db(a) 62 Transport weight kg 800 Dimensions (l x w x h) mm 2200x2100x1450 Technical description: Compact corrosion resistant Rooftop / ventilation unit for outdoor locations. The unit is able to cool as well as heat using the integrated heat pump. Through the simple installation steps of - unloading, attaching air hoses, and attaching electrical power - you will have comfortable temperatures in the shortest possible time. Extensive optional accessories are available. Air distribution: Single air outlet Application example: Double air outlet MRT Design conditions: *Cooling mode: Ambient temp. 35 C ; Room temp. 27 C **Heating mode: Ambient temp. 7 C ; Room temp. 21 C ***On-Site power installation should be entrusted to an electrical specialist. ICE CREAM ICE CREAM TT BANK

79 ACR-RT-80 Technical Specifications - Rental Rooftop units Quick overview: Scroll- Compressor Refrigerant Coolingtemperature Ambienttemperature Heatingtemperature Sound level +40 C 79 Optionally accessories: Air transport R410A Air distribution +15 C bis +25 C Electrical cables +15 C bis +25 C Remote monitoring +5 C low noise Rooftops / Ventilation systems luftdichter Schlauch luftdurchlässiger Schlauch Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 80 **Heating capacity kw 72 Power input - Cooling kw 23 Power input - Heating kw 22 max. operating current - Cooling A 58 max. operating current - Heating A 58 Electrical Connection CEE 63A *** Fuse protection A 63 *** Cable recommendation mm 2 16 Air flow volume m 3 /h External static pressure Pa 206 Capacity control Steps 2 Refrigerant circuits No. 2 Refrigerant R 410A Sound pressure at 5m db(a) 62 Transport weight kg 1600 Dimensions (l x w x h) mm 3200x2300x1600 Technical description: Compact corrosion resistant Rooftop / ventilation unit for outdoor locations. The unit is able to cool as well as heat using the integrated heat pump. Through the simple installation steps of - unloading, attaching air hoses, and attaching electrical power - you will have comfortable temperatures in the shortest possible time. Extensive optional accessories are available. Air distribution: Single air outlet Application example: Double air outlet MRT Design conditions: *Cooling mode: Ambient temp. 35 C ; Room temp. 27 C **Heating mode: Ambient temp. 7 C ; Room temp. 21 C ***On-Site power installation should be entrusted to an electrical specialist. ICE CREAM ICE CREAM TT BANK

80 ACR-RT-83 Technical Specifications - Rental Rooftop units Quick overview: Scroll- Compressor Refrigerant Coolingtemperature Ambienttemperature Heatingtemperature Sound level C Rooftops / Ventilation systems Optionally accessories: Air transport R407C Air distribution +15 C bis +25 C Electrical cables +15 C bis +25 C Remote monitoring +5 C low noise luftdichter Schlauch luftdurchlässiger Schlauch Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 83 **Heating capacity kw 92 Power input - Cooling kw 36 Power input - Heating kw 33 max. operating current - Cooling A 65,5 max. operating current - Heating A 62 Electrical Connection CEE 125A *** Fuse protection A 80 *** Cable recommendation mm 2 25 Air flow volume m 3 /h External static pressure Pa 294 Capacity control Steps 2 Refrigerant circuits No. 2 Refrigerant R 407C Sound pressure at 5m db(a) 66 Transport weight kg 1600 Dimensions (l x w x h) mm 3200x2300x2100 Technical description: Compact corrosion resistant Rooftop / ventilation unit for outdoor locations. The unit is able to cool as well as heat using the integrated heat pump. Through the simple installation steps of - unloading, attaching air hoses, and attaching electrical power - you will have comfortable temperatures in the shortest possible time. Extensive optional accessories are available. Air distribution: Single air outlet Application example: Double air outlet MRT Design conditions: *Cooling mode: Ambient temp. 35 C ; Room temp. 27 C **Heating mode: Ambient temp. 7 C ; Room temp. 21 C ***On-Site power installation should be entrusted to an electrical specialist. ICE CREAM ICE CREAM TT BANK

81 ACR-RT-110 Technical Specifications - Rental Rooftop units Quick overview: Scroll- Compressor Refrigerant Coolingtemperature Ambienttemperature Heatingtemperature Sound level +40 C 81 Optionally accessories: Air transport R407C Air distribution +15 C bis +25 C Electrical cables +15 C bis +25 C Remote monitoring +5 C low noise Rooftops / Ventilation systems luftdichter Schlauch luftdurchlässiger Schlauch Different requirements and applications can be provided on request! Technical specifications: *Cooling capacity kw 110 **Heating capacity kw 126 Power input - Cooling kw 48 Power input - Heating kw 47 max. operating current - Cooling A ca. 100 max. operating current - Heating A ca. 98 Electrical Connection CEE 125A *** Fuse protection A 125 *** Cable recommendation mm 2 50 Air flow volume m 3 /h External static pressure Pa 294 Capacity control Steps 2 Refrigerant circuits No. 2 Refrigerant R 407C Sound pressure at 5m db(a) 62 Transport weight kg 1600 Dimensions (l x w x h) mm 3500x2500x2400 Technical description: Compact corrosion resistant Rooftop / ventilation unit for outdoor locations. The unit is able to cool as well as heat using the integrated heat pump. Through the simple installation steps of - unloading, attaching air hoses, and attaching electrical power - you will have comfortable temperatures in the shortest possible time. Extensive optional accessories are available. Air distribution: Single air outlet Application example: Double air outlet MRT Design conditions: *Cooling mode: Ambient temp. 35 C ; Room temp. 27 C **Heating mode: Ambient temp. 7 C ; Room temp. 21 C ***On-Site power installation should be entrusted to an electrical specialist. ICE CREAM ICE CREAM TT BANK

82

83 Humidification 83 Humidification Always the desired air humidity with the ready to use unit which uses resistance heating. The maximum steam production is about 180kg/h per device and can vary continuously between 0 and 100%. According to the application, the devices can be used as direct or indirect room air moistening in the ventilation and air-conditioning system. With a steam distribution pipe, humidification processes in laboratory or production applications can be realized. The mobile acr air humidifiers are in all areas of application, in which an exact humidity level is required. The areas of application are manifold: For example, the units are used for room air moistening in ventilation and air-conditioning, groceries technology, laboratory and process applications and many other areas.

84 ACR-LB Technical Specifications - Rental humidifier 84 Humidification Technical description: The acr steam air humidifier for direct or indirect room air moistening in ventilation and air-conditioning systems. In combination with a steam distribution pipe also suited for laboratory applications and process applications. The water level in the steam cylinder is continuously monitored. The steam is produced by a variable resistance heating element. Automatic or time-dependent sludge removal from the steam cylinder to maintain the water quality. For operation with untreated drinking water an optional lime retention holder is available. Technical specifications: max. steam capacity at 230V kg/h max. steam capacity at 400V kg/h Voltage V Operating weight kg Dimensions: Width mm x 600 Height mm x 1100 Depth mm x 400

85 85 Heating Air to air heat pumps Page 87 Heating Air to water heat pumps Page 93 Heating systems Page Mobile electric heating 99 Mobile heating systems 103

86

87 Air to air Heatpumps Luft-Luft Wärmepumpen 87 Immer das gewünschte Raumklima zwischen plus 3 C und 30 C: Die sofort betriebsbereiten und für die Außenaufstellung konzipierten Aggregate ohne ein Zwischenmedium erwärmen die Luft direkt. Die Luftverteilung erfolgt mittels leistungsstarker Radialventilatoren. Optional können die Einheiten auch mit Kreislaufumkehrfunktion als Kühlgerät im Frisch-, Misch- und Umluftbetrieb genutzt werden. Die acr Luft-Luft Wärmepumpen finden Anwendung in allen Bereichen, bei denen es gilt, die richtigen Umgebungstemperaturen für Ihren Bedarf sicher zu stellen. Die Anwendungsgebiete sind hierbei vielfältig: Zum Einsatz kommen die Geräte z.b. im Eventbereich, bei Zeltbeheizung/Klimatisierungen, bei Lagerhallen und in vielen anderen Bereichen. Die Aufstellung- und Einbindung ist einfach: Die im acr Mietpark befindlichen mobilen acr Luft-Luft Wärmepumpen sind für die Aufstellung im Freien konzipiert und können auf jedem tragfähigen Boden aufgestellt werden. Nach Anschluss der flexiblen Luftschläuche sowie der Stromversorgung kann die mobile Lüftungszentrale in Betrieb gehen.

88 ACR-RT-60 Technical Specifications - Rental heat pumps Quick overview: Scroll- Compressor Refrigerant Ambienttemperature Heatingtemperature Coolingtemperature Sound level 88 R407C +15 C bis +25 C +15 C bis +25 C +40 C +5 C low noise Optionally accessories: Air transport Air distribution Electrical cables Remote monitoring Air to air Heatpumps luftdichter Schlauch luftdurchlässiger Schlauch Different requirements and applications can be provided on request! Technical specifications: *Heating capacity kw 67 **Cooling capacity kw 56 Power input - Heating kw 20 Power input - Cooling kw 21 max. operating current - Heating A ca. 51 max. operating current - Cooling A ca. 52 Electrical Connection CEE 63A *** Fuse protection A 63 *** Cable recommendation mm 2 16 Air flow volume m 3 /h External static pressure Pa 196 Capacity control Steps 2 Refrigerant circuits No. 2 Refrigerant R 407C Sound pressure at 5m db(a) 62 Transport weight kg 800 Technical description: Compact corrosion resistant heating / ventilation unit for outdoor locations. Besides being a heat pump / in heating mode the unit can also be used to perform cooling by way of an integrated switchover function. Through the simple installation steps of - unloading, attaching air hoses, and attaching electrical power - you will have comfortable temperatures in the shortest possible time. Extensive optional accessories are available. Air distribution: Single air outlet Application example: Double air outlet MRT Design conditions: *Heating mode: Ambient temp. 7 C ; Room temp. 21 C **Cooling mode: Ambient temp. 35 C ; Room temp. 27 C ***On-Site power installation should be entrusted to an electrical specialist. ICE CREAM ICE CREAM TT BANK

89 ACR-RT-80 Technical Specifications - Rental heat pumps Quick overview: Scroll- Compressor Refrigerant Ambienttemperature Heatingtemperature Coolingtemperature Sound level +40 C 89 R410A +15 C bis +25 C +15 C bis +25 C +5 C low noise Optionally accessories: Air transport Air distribution Electrical cables Remote monitoring luftdichter Schlauch luftdurchlässiger Schlauch Different requirements and applications can be provided on request! Air to air Heatpumps Technical specifications: *Heating capacity kw 72 **Cooling capacity kw 80 Power input - Heating kw 22 Power input - Cooling kw 23 max. operating current - Heating A 58 max. operating current - Cooling A 58 Electrical Connection CEE 63A *** Fuse protection A 63 *** Cable recommendation mm 2 16 Air flow volume m 3 /h External static pressure Pa 206 Capacity control Steps 2 Refrigerant circuits No. 2 Refrigerant R 410A Sound pressure at 5m db(a) 62 Transport weight kg 1600 Dimensions (l x w x h) mm 3200x2300x1600 Technical description: Compact corrosion resistant heating / ventilation unit for outdoor locations. Besides being a heat pump / in heating mode the unit can also be used to perform cooling by way of an integrated switchover function. Through the simple installation steps of - unloading, attaching air hoses, and attaching electrical power - you will have comfortable temperatures in the shortest possible time. Extensive optional accessories are available. Air distribution: Single air outlet Application example: Double air outlet MRT Design conditions: *Heating mode: Ambient temp. 7 C ; Room temp. 21 C **Cooling mode: Ambient temp. 35 C ; Room temp. 27 C ***On-Site power installation should be entrusted to an electrical specialist. ICE CREAM ICE CREAM TT BANK

90 ACR-RT-83 Technical Specifications - Rental Rooftop units Quick overview: Scroll- Compressor Refrigerant Coolingtemperature Ambienttemperature Heatingtemperature Sound level C R407C +15 C bis +25 C +15 C bis +25 C +5 C low noise Optionally accessories: Air transport Air distribution Electrical cables Remote monitoring Air to air Heatpumps luftdichter Schlauch luftdurchlässiger Schlauch Different requirements and applications can be provided on request! Technical specifications: *Heating capacity kw 92 **Cooling capacity kw 83 Power input - Heating kw 33 Power input - Cooling kw 36 max. operating current - Heating A 62 max. operating current - Cooling A 65 Electrical Connection CEE 125A *** Fuse protection A 80 *** Cable recommendation mm 2 25 Air flow volume m 3 /h External static pressure Pa 294 Capacity control Steps 2 Refrigerant circuits No. 2 Refrigerant R 407C Sound pressure at 5m db(a) 66 Transport weight kg 1600 Dimensions (l x w x h) mm 3200x2300x2100 Technical description: Compact corrosion resistant Rooftop / ventilation unit for outdoor locations. The unit is able to cool as well as heat using the integrated heat pump. Through the simple installation steps of - unloading, attaching air hoses, and attaching electrical power - you will have comfortable temperatures in the shortest possible time. Extensive optional accessories are available. Air distribution: Single air outlet Application example: Double air outlet MRT Design conditions: *Heating mode: Ambient temp. 7 C ; Room temp. 21 C **Cooling mode: Ambient temp. 35 C ; Room temp. 27 C ***On-Site power installation should be entrusted to an electrical specialist. ICE CREAM ICE CREAM TT BANK

91 ACR-RT-110 Technical Specifications - Rental heat pumps Quick overview: Scroll- Compressor Refrigerant Ambienttemperature Heatingtemperature Coolingtemperature Sound level +40 C 91 R407C +15 C bis +25 C +15 C bis +25 C +5 C low noise Optionally accessories: Air transport Air distribution Electrical cables Remote monitoring luftdichter Schlauch luftdurchlässiger Schlauch Different requirements and applications can be provided on request! Air to air Heatpumps Technical specifications: *Heating capacity kw 126 **Cooling capacity kw 110 Power input - Heating kw 47 Power input - Cooling kw 48 max. operating current - Heating A ca. 98 max. operating current - Cooling A ca. 100 Electrical Connection CEE 125A *** Fuse protection A 125 *** Cable recommendation mm 2 50 Air flow volume m 3 /h External static pressure Pa 294 Capacity control Steps 2 Refrigerant circuits No. 2 Refrigerant R 407C Sound pressure at 5m db(a) 62 Transport weight kg 1600 Dimensions (l x w x h) mm 3500x2500x2400 Technical description: Compact corrosion resistant heating / ventilation unit for outdoor locations. Besides being a heat pump / in heating mode the unit can also be used to perform cooling by way of an integrated switchover function. Through the simple installation steps of - unloading, attaching air hoses, and attaching electrical power - you will have comfortable temperatures in the shortest possible time. Extensive optional accessories are available. Air distribution: Single air outlet Application example: Double air outlet MRT Design conditions: *Heating mode: Ambient temp. 7 C ; Room temp. 21 C **Cooling mode: Ambient temp. 35 C ; Room temp. 27 C ***On-Site power installation should be entrusted to an electrical specialist. ICE CREAM ICE CREAM TT BANK

92

93 Air to water Heatpumps Air to water heat pumps 93 With a capacity from 12kW to 450kW per heat pump, fluids can be heated up to plus 50 C. The especially compact, environmentally friendly heat pumps can be used for heating as well as cooling. The acr heat pumps can be applied in all areas where liquids or air is to be heated. The areas of application are manifold. The devices can for example be used for building, event- and tent heating, in production processes, test setups and in many other areas. The installation and integration is very simple: The heat pumps in the acr rental park are designed for outdoor installation and can be installed on any viable ground. After connecting the pre-configured flexible hoses, as well as the power cabling, the heat pump can go into operation.

94 ACR-M-12/WP/P Technical Specifications - Rental heat pumps Quick overview: Scroll- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Sound level C R407C bis +50 C +5 C low noise Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring Air to water Heatpumps DN 40 Storz C up to 40m pressure head Different requirements and applications can be provided on request! Technical specifications: *Heating capacity kw 13,2 Power input kw 5 Voltage V/Hz/Phases 400/50/3 Operating current A 14 Electrical Connection CEE 16A ** Fuse protection A 16 ** Cable recommendation mm 2 2,5 Flow rate m 3 /h 2,0 Technical description: Air to water heat pumps with reversible operation can be used for heating/cooling. The unit is equipped with quiet running scroll compressors. The heat pump has an integrated pump with a head height of 28m (280kPa), it should be set up on a horizontal, stable area, and should have at least 1m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 6 External pressure head m 19 Cold water connections Storz C Capacity control Steps 1 Refrigerant R 407C Sound pressure at 10m db(a) 51 Transport weight kg 225 Dimensions (l x w x h) mm ca. 1490x730x1670 * Design conditions: Hot water temperatures 40/45, Ambient temperature 7 C **On-Site power installation should be entrusted to an electrical specialist. Electrical connections with CEE-plugs Hot water connection with Storz-plugs

95 ACR-M-39/WP/P Technical Specifications - Rental heat pumps Quick overview: Scroll- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Sound level +40 C 95 R407C bis +50 C +5 C low noise Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring DN 40 Storz C up to 60m pressure head Different requirements and applications can be provided on request! Air to water Heatpumps Technical specifications: *Heating capacity kw 40 Power input kw 16,2 Voltage V/Hz/Phases 400/50/3 Operating current A 39 Electrical Connection CEE 63A ** Fuse protection A 50 ** Cable recommendation mm 2 10 Flow rate m 3 /h 6,88 Technical description: Air to water heat pumps with reversible operation can be used for heating/cooling. The unit is equipped with quiet running scroll compressors. The heat pump has an integrated pump with a head height of 14m (140kPa), it should be set up on a horizontal, stable area, and should have at least 1m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 14 Cold water connections Storz C Capacity control Steps 2 Refrigerant R 407C Sound pressure at 5m db(a) 62 Transport weight kg 560 Dimensions (l x w x h) mm 2200x1210x1490 * Design conditions: Hot water temperatures 40/45, Ambient temperature 7 C **On-Site power installation should be entrusted to an electrical specialist. Electrical connections with CEE-plugs Hot water connection with Storz-plugs

96 ACR-M-60/WP/P Technical Specifications - Rental heat pumps Quick overview: Scroll- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Heat pump function C R410A bis +50 C -20 C bis +45 C Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring Air to water Heatpumps DN 80 Storz B up to 60m pressure head Different requirements and applications can be provided on request! Technical specifications: *Heating capacity kw 60 Power input kw 19,3 Voltage V/Hz/Phases 400/50/3 Operating current A 60,5 Electrical Connection Cable terminals - ** Fuse protection A 63 ** Cable recommendation mm 2 16 Flow rate m 3 /h 9,72 Technical description: Air to water heat pumps with reversible operation can be used for heating/cooling. The unit is equipped with quiet running scroll compressors. The heat pump has an integrated pump with a head height of 17m (170kPa), it should be set up on a horizontal, stable area, and should have at least 1m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 12 Cold water connections Storz B Capacity control Steps 2 Refrigerant R 410A Sound pressure at 5m db(a) 58 Transport weight kg ca Dimensions (l x w x h) mm 2870x1200x2020 * Design conditions: Hot water temperatures 40/45, Ambient temperature 7 C **On-Site power installation should be entrusted to an electrical specialist. Control cabinet with electrical connections Hot water connection with Storz-plugs

97 ACR-M-70/WP/P Technical Specifications - Rental heat pumps Quick overview: Scroll- Compressor Refrigerant Processtemperature Ambienttemperature Integrated pump Heat pump function +40 C 97 R410A bis +50 C -20 C bis +45 C Optionally accessories: Cold water tubes Pump modules Heat exchanger Buffer storage Electrical cables Remote monitoring DN 80 Storz B up to 60m pressure head Different requirements and applications can be provided on request! Air to water Heatpumps Technical specifications: *Heating capacity kw 80 Power input kw 25 Voltage V/Hz/Phases 400/50/3 Operating current A 63 Electrical Connection Cable terminals - ** Fuse protection A 80 ** Cable recommendation mm 2 25 Flow rate m 3 /h 12,96 Technical description: Air to water heat pumps with reversible operation can be used for heating/cooling. The unit is equipped with quiet running scroll compressors. The heat pump has an integrated pump with a head height of 16m (160kPa), it should be set up on a horizontal, stable area, and should have at least 1m free space to all sides. All controls and regulators are contained within the housing. Maximum operating pressure bar 10 External pressure head m 11 Cold water connections Storz B Capacity control Steps 2 Refrigerant R 410A Sound pressure at 5m db(a) 62 Transport weight kg ca Dimensions (l x w x h) mm 2870x1200x2400 * Design conditions: Hot water temperatures 40/45, Ambient temperature 7 C **On-Site power installation should be entrusted to an electrical specialist. Control cabinet with electrical connections Hot water connection with Storz-plugs

98

99 Mobile electric heaters Mobile electric heaters 99 The efficient electric heaters are used in all applications and in all areas, where fluids are to be heated. The areas of application are manifold. These devices come into action when a heating plant goes down, or is in maintenance, in order to prevent frost damage, during the installation of floor heating, to warm up the screed, or as emergency heating or also as a load bank for a chiller.

100 Technical Specifications - Rental electric water heaters 9-36kW 100 Mobile electric heaters Technical description: Mobile acr electric heaters with a heat capacity of 9 kw. The device is connected with a CEE connector and is immediately ready for use. Through the operation with three phase current, no exhaust fumes emerge and therefore the heater can be set up directly inside the building. The standard equipment includes all required components, such as recirculating pump, expansion container, safety fittings as well as a temperature regulator. The heater is preassembled and mounted on a hand cart which can be setup or dismantled by one person. For all scopes such as heat emergencies, reconstruction works, research and development, a mobile acr electric heater can be quickly and simply rented. Technical specifications: Heating capacity kw Capacity range kw 4,2 bis 8,4 7,2 bis 14 14,4 bis 21 21,6-28,8 30 bis 36 Electrical Connection - 16 A CEE 32 A CEE 32 A CEE 63 A CEE 63 A CEE Degree of protection - IP 44 / F IP 44 / F IP 44 / F IP 44 / F IP 44 / F Max. operating temperature C Temperature range C Water treatment - Optional Optional Optional Optional Optional Pump - yes yes yes yes yes Expansion Litre Protection - Heater bar Connection pipe - Gekaplugs Gekaplugs Gekaplugs Gekaplugs Gekaplugs Length mm Width mm Height mm Weight (without water) kg ca. 60kg ca. 60kg ca. 60kg ca. 60kg ca. 60kg

101 Technical Specifications - Rental electric air heaters - 15kW Technical description: Compact electric heater for warming up air. The heating capacity can be regulated through it three power steps. Therefore the units can be used for smaler as well as bigger rooms. In case of overheating the units switches of through it's integrated thermostates. 101 Technical specifications: Heating capacity kw 15 Voltage V/Hz/Ph 400/3/50 Electrical Connection - 32 A CEE Maximaler Operating current A 22 Air flow m 3 /h 85 Length mm 350 Width mm 440 Height mm 600 Weight kg ca. 16kg Mobile electric heaters

102

103 Mobile Heating systems Mobile Heating systems 103 Mobile heat systems from 50 up to 1,000kW heating capacity is suited for the most varied applications for heating. Whether for industrial solutions such as process warmth or as a heat provision for reconstruction measures, as public district heating or for warm water and warm air provision. The heat systems are alternatively available as a trailer- or container variant. The connection takes place via flexible connection tubes, the recirculating pump is integrated in the heat module. The fuel tank is integrated and heating oil is used as a fuel.

104 Technical Specifications - Mobile heating systems Technical description: Heat system for the provision of mobile warmth with heating, warm water production, recirculating pump, expansion container and integrated tank plant. As a fuel, heating oil is used and the regulation fulfils all requirements. Due to the light design, the plant can be flexibly and easily transferred. The operation takes place comfortably at standing height via a side lid. The connection is done via flexible connection lines. Mobile Heating systems Technical specifications: Heating capacity kw Hot water C 70/90 70/90 70/90 70/90 Domestic hot water C 45/60 45/60 45/60 - Safety pressure bar 3 / 10 3 / 10 3 / 10 - Delivery data of main pump m 3 /h 4, Pressure head main pump m ,5 Hot water output 45 C l/h Circulation DHW - yes yes yes - Capacity of heating oil tank, internal Litre Remote-/ tank-monitoring - optional optional optional optional Flue system - Stainless steel stack Stainless steel stack Stainless steel stack Stainless steel stack Voltage V / A 230V / 16A 400V/CEE 16A 400V/CEE 16A 400V/CEE 32A Length (without drawbar) mm Width mm Height mm Weight (without oil/water) kg ca ca ca ca

105 105 Power supply Emergency power supply aggregates Page 107 Power supply

106

107 Emergency power supply aggregates 107 Whether as a redundancy for especially sensitive areas or as a temporary power supply, acr delivers emergency power supplies of 100 up to 500kVA. The sound damped aggregates include an integrated or external double-walled tank with 1,200l, 2,400l, 2,750, 5,200 or 11,000l dependent on the model variant. The devices have as standard equipment a Starter battery- maintenance as well as a preheat function for smooth starting of the unit. Extensive accessories such as cable or mesh generator- control cabinet for the automatic switching of network power or emergency power are available. Power supply

108 ACR-SA Technical Specifications - Mobile power supply 108 Power supply Technical specifications: Prime power kva (cos phi 0,8) 250 Voltage V 400 Frequency Hz 50 Sound pressure (Full Load) db(a) in 7m 70 Fuel tank l (intern) 240 Fuel consumption (Full load) l/h ca. 50 Refuel period (permanent operation) h 5 (Optional ext. Tank verfügbar) Fuel - Heizöl Length mm Width mm Height mm Transport weight kg Operating weight kg Accessories Lockable doors Terminal buses, Screw M10 Lifting eye Automatic control Optional Cable Wiring closet External safety fuel tank

109 ACR-SA Technical Specifications - Mobile power supply 109 Technical specifications: Prime power kva (cos phi 0,8) 300 Voltage V 400 Frequency Hz 50 Sound pressure (Full Load) db(a) in 7m 70 Fuel tank l 270 Fuel consumption (Full load) l/h ca. 60 Refuel period (permanent operation) - 4,5 (Optional ext. Tank verfügbar) Fuel - Heizöl Length mm Width mm Height mm Transport weight kg Operating weight kg Power supply Accessories Lockable doors Terminal buses, Screw M10 Lifting eye Automatic control Optional Cable Wiring closet External safety fuel tank

110 ACR-SA Technical Specifications - Mobile power supply 110 Power supply Technical specifications: Prime power kva (cos phi 0,8) 500 Voltage V 400 Frequency Hz 50 Sound pressure (Full Load) db(a) in 7m 69 Fuel tank double-walled (Internal) Litre 1500 Fuel consumption (Full load) l/h ca. 100 Refuel period (permanent operation) h ca. 15 Fuel - Heizöl Length mm Width mm Height mm Transport weight kg Operating weight kg Accessories Cooling water pre-heater, Battery charger Lockable doors Terminal buses, Screw M 12 Optional Automatic control Cable Wiring closet External safety fuel tank

111 111 Accessories Hydraulic Page 112 Pumps- and pump modules 113 Plate heat exchanger 117 Hydraulic modules 121 Cold water tubes, couplings, valves, fittings 123 Storage, distributor, hydraulic splitter 127 Air distribution Page 129 Electric Page 131 Cable, Frequency converter, Remote monitoring 132 Accessories Sound reduction Page 133 Operational materials Page 137

112 112 HYDRAULIC Pumps- and pump modules 113 Plate heat exchanger 117 Accessories Hydraulic modules 121 Cold water tubes, couplings, valves, fittings 123 Storage, distributor, hydraulic splitter 127

113 Pumps and pump modules 113 Mounted as single or double pump(s) on a sturdy steel frame. Also attached is a control cabinet with all the necessary electrical switching components. Extensive optional accessories such as three way valves, changeover valves, frequency converter, expansion tank, actuators, sound attenuation and weatherproof housing is available. The acr pump modules are in stock with a capacity of over 300 m³/h at a maximum head of 50 meters and are suitable for media temperatures of minus 45 to plus 95 C. Higher capacities and other temperature ranges can be provided upon request. The acr pump modules are used wherever fluids must be transported. Acr offers the corresponding aggregates for almost all applications such as for cooling, air conditioning and heating applications. The areas of application are manifold: For example, the modules are used in building air-conditioning, waste water technology, production processes, test setups, medical technology, pharmaceuticals, food processing, beverage industry, chemical industry, plastics industry, and in many other areas. Accessories The installation and integration is very simple: Due to its compact dimensions and the frame structure, the modules can be easily unloaded and transported by forklift truck. The mobile pump modules in the acr rental park are designed for installation in a dry, frost-free location and can be installed outdoors with optional provisions. After connecting the pre-configured flexible hoses and the power cabling the pump module can be filled and can go into operation.

114 Pump and pump modules from 2 up to 70m 3 /h 114 Technical description: The acr pump modules are mounted on a stable steel frame as single pumps, double pumps or high pressure pumps with control cabinet and alternatively with or without sound damped housing. An expansion container as well as a security valve are integrated, the pumps that we have in stock have a capacity of over 300 m³/h, at a maximal head height of 50 meters and are suitable for a medium temperature of minus 45 up to plus 95 C. Higher capacities and other temperature ranges can be provided upon request. Extensive accessories such as three way valves, shift valves, frequency converters, expansion containers, actuators are optionally available. Accessories Technical specifications: Pump type - PM_2-7 PM_3-7 PM_5-30 PM_15-30 PM_16-42 PM_10-54 DPM_10-65 PM_14-84 Singlepump Singlepump Highpressure Singlepump Singlepump Singlepump Singlepump Doublepump with VFD Flow rate m 3 /h Pressure head m Max. operating pressure bar ca ca. 16 ca. 16 ca. 16 ca ca. 16 Capacity kw 0,75 1,1 0,88 3 1,5 1,8 0,75 5,9 Nominal current A 2 2,4 1,7 6,1 3,45 4,2 1,9 14,1 * Water connections Type Storz C Storz B - Storz B Storz B Flange/ Storz Singlepump - - Expansion tank yes/no no - no yes no no no - 3-way-valve yes/no no - no no no no no - Cabinet yes/no yes yes yes yes yes yes yes yes Dimensions: Length mm 600 ca ca Width mm 480 ca ca Height mm 630 ca. 600 ca * Connections could be configured individually Electrical requirements: Voltage (400V / 50 Hz / 3Ph+N+PE), Protection class IP54. Insulation class F. On-Site power installation should be entrusted to an electrical specialist.

115 Pump and pump modules from 15 up to 300m 3 /h Technical description: The acr pump modules are mounted on a stable steel frame as single pumps, double pumps or high pressure pumps with control cabinet and alternatively with or without sound damped housing. An expansion container as well as a security valve are integrated, the pumps that we have in stock have a capacity of over 300 m³/h, at a maximal head height of 50 meters and are suitable for a medium temperature of minus 45 up to plus 95 C. Higher capacities and other temperature ranges can be provided upon request. Extensive accessories such as three way valves, shift valves, frequency converters, expansion containers, actuators are optionally available. 115 Technical specifications: Pump type - PM_ PM_ PM_ PM_ DPM_ DPM_ PM_ PM_ Single-pump low temp Singlepump VFD Highpressure Singlepump Singlepump Doublepump with VFD Doublepumpe Singlepump with folow switch Flow rate m 3 /h Pressure head m Max. operating pressure bar ca Capacity kw 11 7, Nominal current A 19,7 13, ,2 20, * Water connections Typ Storz A/B - Flange DN 80 Storz A Flange DN125 Singlepump Expansion tank yes/no yes yes no - yes yes yes yes 3-way-valve yes/no no yes no - no - no no Cabinet yes/no yes yes yes yes no yes yes no Accessories Dimensions: Length mm 1700 ca ca Width mm 750 ca ca Height mm 1200 ca ca * Connections could be configured individually Electrical requirements: Voltage (400V / 50 Hz / 3Ph+N+PE), Protection class IP54. Insulation class F. On-Site power installation should be entrusted to an electrical specialist.

116

117 Heat exchangers 117 Heat exchangers achieve a separation between the primary circuit and the secondary circuit on the basis of differing temperatures, media or different pressures. The heat exchangers are mounted on stable feet or steel frames and are in stock and available for flow rates up to 180 m³/h per module. For greater capacities, these can respectively be arranged in parallel. The medium temperature can vary depending on the equipment version between minus 45 degrees to plus 120 C. The installation and integration is very simple: Due to its compact dimensions and the frame structure, the modules can be easily unloaded and transported by forklift truck. The mobile modules in the acr rental park are designed for installation in a dry, frost-free location and can be installed outdoors with optional provisions. After connection of the preconfigured flexible tubes, the system separation modules can be filled and put into operation. Accessories

118 Heat exchanger from 4 up to 210m 3 /h 118 Technical description: The acr plate heat exchangers are mounted on stable steel feet and are available for flow quantities of 2 to 180 m³/h per module, for medium temperatures between minus 45 up to plus 120 C. If larger capacities should be required, these can also be connected in parallel. The standard heat exchangers executed in stainless steel are best suited for system separation when ground water cooling. For extremely corrosive media such as salt brine mixtures, titanium plate heat exchangers are available. Higher capacities and other temperature ranges and pipe bundle heat exchangers can be provided upon request. Accessories Technical specifications: Heatexchanger type - PW_4-4 PW_11-12 PW_30-15 PW_49-54 PW_63-72 Plate/ stainless steel Plate/ stainless steel Plate/ Stainless steel Plate/ Stainless steel Plate/ Stainless steel Design - brazed bolted brazed bolted brazed Flow rate primary/secondary m 3 /h 5,5 / 2,7 12/11 16/34 49/56 61/69 Temperature range C -200/+200 ca. -20/ /+190 ±0/+50 bis 225 C Pressure range bar 40 ca. 10 ca. 30 ca. 10 ca. 25 * Primary connections Typ * * * Flange DN100 * * Secondary connections Typ * * * Flange DN100 * Weight (ca.) kg ca. 40 ca. 270 ca. 200 ca ca Dimensions: Length mm ca. 300 ca. 900 * 2100 * Width mm ca. 200 ca. 500 * 650 * Height mm ca ca.1600 * 2150 * * Connections could be configured individually

119 Heat exchanger from 4 up to 210m 3 /h Technical description: The acr plate heat exchangers are mounted on stable steel feet and are available for flow quantities of 2 to 180 m³/h per module, for medium temperatures between minus 45 up to plus 120 C. If larger capacities should be required, these can also be connected in parallel. The standard heat exchangers executed in stainless steel are best suited for system separation when ground water cooling. For extremely corrosive media such as salt brine mixtures, titanium plate heat exchangers are available. Higher capacities and other temperature ranges and pipe bundle heat exchangers can be provided upon request. 119 Technical specifications: Heatexchanger type - PW_ PW_ PW_ PW PW_ Plate/ Stainless steel Plate/ stainless steel Plate/ stainless steel Plate/ stainless steel Plate/ stainless steel Design - bolted bolted bolted bolted bolted Flow rate primary/secondary m 3 /h 69/69 72/70 162/ / /186 Temperature range C ca. -20/ /+155 ca. -20/+90 0/+90-10/80 Pressure range bar /16 23/6 10 * Primary connections. Typ * Storz B Flange DN100 * * * Secondary connections. Flange Typ * DN 65 Flange DN100 * * Weight (ca.) kg ca. 350 ca. 250 ca ca ca. 700 Accessories Dimensions: Length mm ca ca ca ca Width mm ca ca ca. 850 ca. 750 Height mm ca ca ca ca * Connections could be configured individually

120

121 Hydraulic modules 121 Hydraulics module for the separation between primarily circuit and secondary circuit to allow for a higher temperature level at the load or at a lower outside temperature, the load should be impinged with water. The modules are constructed on a stable steel frame. Extensive accessories like switching / control cabinets, pumps, three way valves are included. Optionally the modules can be delivered with shift valves, frequency converters, expansion containers, actuators, sound dampers and weather protection housings. The acr hydraulic modules are in stock for flow rates up to 180 m³/h per module. For greater capacities, these can respectively be arranged in parallel. The medium temperature can vary depending on the equipment version between minus 45 degrees to plus 95 C. Higher capacities and other temperature ranges can be provided upon request. Accessories The installation and integration is very simple: Due to its compact dimensions and the frame structure, the modules can be easily unloaded and transported by forklift truck. The mobile modules in the acr rental park are designed for installation in a dry, frost-free location and can be installed outdoors with optional provisions. After connecting the pre-configured flexible hoses and the power cabling the system separation module can be filled and can go into operation.

122 Hydraulic modules von 2 bis 180m 3 /h 122 Technical description: Acr hydraulic modules for separation between primarily circuit and secondary circuit through a plate heat exchanger as well as fluid transport by the integrated pump. Hydraulics and electrics completely mounted on a base frame. 3-away mixing valve with microprocessor control of the specified temperature, expansion container, security valve, manometer as well as integrated dirt catcher. A primary side flow detector is included which protects against dry running the primary pump. The medium temperature can vary depending on the equipment version between minus 45 degrees to plus 95 C. Higher capacities and other temperature ranges can be provided upon request. Extensive optional accessories are available. Accessories Technical specifications: Hydraulic module-type ACR HM ACR HM ACR HM ACR HM Double pumpe with heatexchanger Pump with heatexchanger Pump with heatexchanger Pump with heatexchanger Flow rate plate primary/secondary m 3 /h 16/14 24/31 27/44 43/173 Flow rate (pump) m 3 /h Capacity (pump) kw 3, Nominal current (pump) A 6,1 6,1 19,7 30 max. pressure head m * max. pressure range bar ca. 16 ** Primary connections. Typ ** DN100/65 Storz B ** ** Secondary Typ ** DN100/65 Storz B ** connections. Temperature range C ca. -20/+90 ca. -20/+90 ca. -20/+90 ca. -20/+90 Valves Typ 3-way-valve 3-way-valve - 3-way-valve Expansion tank yes/no yes yes yes - Dimensions: Length mm ca Width mm ca Height mm ca Anmerkung: * Higher pressures on request ** Connections could be configured individually Electrical requirements: Voltage (400V / 50 Hz / 3Ph+N+PE), Protection class IP54. Insulation class F. On-Site power installation should be entrusted to an electrical specialist.

123 Cold water tubes, couplings, valves, fittings 123 Cold water tubes and couplings: Flexible fluid / cold water tubes to carry fluids in all common sizes. With quick couplings, flanges, Victaulik couplings as well as transition reducers. Through simple connecting of the individual tubes, any lengths and connections are configurable. Valves and fittings: Also special accessories such as thermostats, pressure sensor and flow measuring instruments and further fittings as well as lids, regulator-, switchover-, motor-, two way- and three way- valves for hydraulic linking are available on request. Accessories

124 Cold water tubes, couplings, valves, fittings Flexible Liquid / cold water hoses: 124 Flexible, acid resistant hoses from DN 40 to DN125 standard available and suitable for temperatures from minus 30 C to plus 80 C at an operating pressure of up to 10 bar. By simply connecting the individual tubes any length can easily be configured. Thanks to the quick couplings, intermediate pieces, and flange transition pieces, all connection variants and distributions can easily be implemented. Outside diameter Bend radius Weight [DN] [mm] [Zoll] [mm] [kg/m] [l/m] ½ 230 1,3 1, ,9 2, ½ 380 2,7 3, ,4 4, ,7 8, ,67 Fill-up quantity (water with 4 C) Tube couplings and connections: The acr couplings and adapters allow for a problem-free hydraulic combination of the individual components and makes the transport of fluids a straightforward matter. Acr has readily available all common quick couplings such as those from Bauer, Storz as well as intermediate pieces and transitions to flanges or Victaulic. Accessories Storz Distance between claws Tube diameter 52-C 31 mm DN B 66 mm DN A 89 mm DN mm DN 125 Flange DIN PN 10 DIN PN 16 DN D k n d2 D k n d n = number of screw holes

125 Cold water tubes, couplings, valves, fittings Flap gates/ valves: All conceivable assemblies for closing off as well as for flow rate regulation such as: - Lids-, - Regulator-, - Switchover-, - Motor-, - two way- and three way valves 125 are available in the rental product line Fittings: Acr delivers an extensive spectrum of fittings such as: - Manometer - Thermometer - Flow detector - Flow measuring instrument - Filling- and drain valves - Venting valves - Pressure and temperature sensors For the hydraulic linking to the acr rental systems. Accessories

126

127 Storage, distributor, hydraulic splitter 127 Buffer storage: Storage modules to enlarge and stabilize the total system. Storage modules can be modularly assembled, can be easily implemented with flexible tube technology, the linking is possible without any problems. Divider: Cold water divider for connection at the chiller for distribution to several loads and/or load circuits. Hydraulic switches: Hydraulic separation between generator circuit and load circuit to balance out fluctuating loads and pressures. According to cold capacity and flow rate available in different sizes. Accessories

128 Storage, distributor, hydraulic splitter 128 Storage: Storage modules in Multiflex construction provide the merger of several vessels to adapt to the current system performance. Therefore an expansion of the storage volume as needed or required is possible at any time. By way of the module design, transport and integration problems are avoided; and the assembly and linking is possible without any problems due to the tube technology. Alternately larger buffer storage are available up to 10 m³ per piece. Accessories Divider and hydraulic switches: Divider: Cold water divider for connection at the chiller circuit for distribution to several loads and/or load circuits. Available in all required sizes on inquiry. Hydraulic switches: Is used to decouple the generator circuit and load circuit. For heavily fluctuating loads and pressures, a hydraulic decoupling is required for smooth operation. Dependent on the cooling capacity and the resulting flow rate, acr can deliver hydraulic switches in various sizes.

129 Air distribution 129 Airtight and porous tubes for the transport and distribution of the cooled or heated air quietly and draught free to all areas. The flexible textile / foil tubes have a diameter of 400 mm up to 1000 mm and are on hand in our warehouse and can extended without any problems. The tubes do not contain plasticizers and are thus odorless. Accessories

130 Air distribution Airtight tube 130 The flexible and airtight PVC coated Polyamide textile tubes for medium temperatures have an outside spring steel spiral. For the transportation of cold or warm air in mobile ventilation systems or air-air heat pumps. The field of application extends from tents, through office space to warehouse halls. Tube diameter D [mm] Air distribution (Y divider) Y divider for branching and/or distribution of the air flow. Accessories Porous tube Porous textile air tubes for the draught free and quiet transfer of the cooled or heated air. The flexible textile tubes are available with a diameter between 400 mm and 1000 mm. The individual tubes can be configured depending on the dynamic pressure of the ventilation device at the necessary lengths.

131 Electric 131 Electrical cable: Flexible single or multiple conductor cable of 1.5 mm² up to 240mm² for the connection of mobile devices and machines in dry and damp rooms as well as in the outdoors. Frequency converter: Stepless speed regulation of compressors, ventilators and pumps for system control as well as power adjustment. Remote monitoring: GSM alarm module for the transmission of the status message of the acr rental machines around the clock. Accessories

132 Cable, Frequency converter, Remote monitoring 132 Cables For our rental park we have in stock, flexible power cable from 1.5 mm² to 240 mm² per core cross-section available for connecting mobile devices and machines. They are suitable for medium mechanical stresses in dry and damp rooms as well as in the outdoors. Connection possibilities: CEE- connector with 16A, 32A, 63A and 125A Wire end sleeves Cable terminals from 10mm² to 240mm² Accessories Frequency converter Frequency converter for step less speed regulation of compressors, ventilators and pumps for system control as well as power adjustment. Besides operating cost reduction, further advantages in the exact partial load regulation lie in the reduced starting current requirement as well as noise reduction. On customer requests, the acr rental machines and accessories such as pumps and hydraulics modules with frequency converter can be delivered. Remote monitoring Available as a separate module for integration with the rental items. The transmission of data and commands always goes over the mobile telephone network. The remote monitoring module monitors the operation of rental equipment around the clock. Depending on the version and settings, the corresponding module can be quickly changed, and problems can be acknowledged and documented as well. However, even if an on-site repair is required, systems analysis will be helpful in counteracting the problem. The service technician will have the necessary materials for the repair in advance to minimize the downtime of the machines. The integration is straightforward: There is no need to intervene in the existing data network of the customer, because the transmission of data is via the mobile telephone network. Therefore, privacy concerns are unfounded. The integration of the remote monitoring module is optionally available for most acr rental items.

133 Sound reduction 133 Compressor cabinet: The acr chillers with compressors are optionally available in cabinets with a sound reduction of 10 up to 15dB(A) at a distance of 5m. Sound hood: As an additional measure, the noise of the axial ventilators can be reduced by about 8dB(A) by applying a sound hood fitting over the ventilators. Sound protection wall: Prefabricated, custom formed elements of laminated rock wool for sound absorption and as a visibility protection guarantee an additional reduction of the noise values of up to about 15 db(a). Accessories

134 Sound reduction 134 Compressor cabinet: According to sound requirements, the acr chillers are optionally available with enclosed compressors which provide for a considerable sound reduction of 10 up to 15dB(A) at a distance of 5m. Sound hood If the compressors are already enclosed, a sound hood can also be installed as an additional measure to reduce the sound of the axial ventilators. With the sound hood, that are installed over the ventilators, the sound pressure level can be reduced up to about 8dB(A). Accessories Sound propagation without sound hood Sound propagation with sound hood

135 Sound reduction Sound protection wall Consisting of prefabricated elements, which are form-locking. The element itself is made of laminated rock wool and is available in different sizes. Besides good sound absorption, the elements are flame retardant. Due to the low module weight the portable sound barriers can easily be transported and assembled. Already in the standard version the acr aggregates are extremely low sound levels in operation. These sound barriers - which also serve as blinds - provide an additional reduction of noise levels by up to 15 db(a). 135 Accessories

136

137 Operational materials 137 Cooling brine concentrate on the basis of Monoethyl- or Monopropylene glycol: At cold water temperatures < 4 C or if frost is to be expected, brine is available for the existing fluid system and can be delivered in the required mixture ratio. Special cooling brine media: Salt-brine-mixture for extremely low temperatures at special deep cooling applications. Accessories

138 Operational materials Operational materials: 138 The operational materials of the rental machines such as chiller oil and refrigerants are reviewed by acr before delivery and/or at regular intervals. Operational materials necessary for the existing fluid system e.g. antifreeze (Monoethyl- or Propylene glycol) for cold water temperatures <4 C or if frost is to be expected, and can be delivered in the required mixture ratio. Accessories C Fluid Area Solid area Slush Vol. % Cooling brine concentrate on the basis of Monoethyl- glycol: Long-term frost protection concentrate with corrosion inhibitors as a cooling brine and/or warmth carrier fluid. Cooling brine concentrate is completely mixable with water and is mixable with all antifreezes on basis of the Monoethyl- glycol. Frost protection from -9 C (at 20% cooling brine concentrate) down to -40 C (at 50% cooling brine concentrate) Cooling brine concentrate on the basis of Monopropyl- glycol: Long-term frost protection concentrate with corrosion inhibitors as a cooling brine and/or warmth carrier fluid. Cooling brine concentrate is completely mixable with water and is mixable with all antifreezes on basis of the Monopropyl- glycol. Frost protection from -6 C (at 20% cooling brine concentrate) down to -32 C (at 50% cooling brine concentrate) Special cooling brine media: For extremely low temperatures or in special applications salt-brine-mixtures can be delivered.

139 139 Specialty plants Page 140 Specialty plants

140 Specialty plants If none of the standard products in the range fulfil the requirements, acr chiller rent also have special plants in the rental program. If the suitable product should not be on hand, acr can offer through its in-house special plant manufacturing, a customer-specific rental solution. 140 Specialty plants Fields of application of the acr special plant manufacturing: - Extremely quietl machines with a sound pressure level <50dB(A) at 5 m distance - Machines with extremely compact dimensions - Extremely low temperature ranges down to -45 C - Large cooling systems with Turbo compressors and cooling capacities up to 4,500kW per unit - Heat recovery- machines for process, heating- or hot water heating. - external pump modules with single pumps or double pumps up to a delivery rate of 450m³/h - Hydraulics modules with plate heat exchangers and pump for system separation with flow rates up to 180m³/h per module

141 141 Second hand Page 142 Second hand

142 6. Second hand 142 acr chiller rent has efficient and good as new machines available for rent. High customer satisfaction is based not in the least on the well-known reliability of our rental items. Therefore the modern acr rental park is constantly being re-equipped with new machines. Some acr units have had no more than 100 hours of operation. At acr you have the opportunity to acquire a professionally certified refrigeration machine like new at the most favorable terms. Whether a used chiller, deep cooling chiller, dry cooler, heat pump or heat system acr offers devices for the entire spectrum of refrigeration, air-conditioning and heating technology. Please speak to us! Second hand

143 143 FAQ FAQ Fragen und Antworten Refrigeration technology 144 Air-conditioning 149 Heating 152 Power supply 154 Accessories and integration 156 Machine commissioning 166 Liability exclusion and copyright: gives no guarantee at all for the completeness, correctness and relevance of the information provided. Liability claims against acr which may be caused through the use of the offered information and/or through the utilization of defective and incomplete information are in all cases excluded. Acr reserves the right to change, to supplement, to delete parts or all of the pages or the entire offer or to adjust the publication without separate announcement. The contents generated by acr on these pages are subject to the German copyright laws. The duplication, preparation, distribution and any other type of utilization outside of the boundaries of the copyright laws need the written approval of. Downloads and copies of these pages are allowed only for private, non-commercial use. As far as the contents on these pages were not generated by acr, the copyrights of third parties are noted. FAQ

144 144 Refrigeration - FAQ FAQ

145 FAQ - Refrigeration Rule of thumb: What is the EER value and how is it calculated? The EER (energy efficiency ratio) defines the performance number of a refrigeration unit, i.e. the ratio of the cooling produced to the consumption of electric energy. EER = Q 0 /P KL 145 How is the ratio of cooling capacity to the clamp achievement (EER) of the acr rental machines? Dependent on air or water-cooled chillers, the efficiency varies considerably. Our large cooling systems with centrifugal-compressors for example reach EER values of > 5. For the standard product assortment, the following values can be assumed. - EER in deep cooling machines 1 to 2 - EER in air cooled chillers 2.5 to EER in water cooled chillers 3.5 to 6 Is there a guideline for the variation of the cooling capacity per C temperature change of the cold water temperatures? As a rule of thumb, per K temperature reduction the cooling capacity decreases by about 4%. Is there a guideline for the flow rate in dependence of the cooling capacity? As a guideline, for the flow rate per kw cooling capacity, dependent on t (temperature difference between cold water inlet and discharge) the following values can be assumed. t 4K 215 l/h per kw cooling capacity t 5K 172 l/h per kw cooling capacity t 6K 143 l/h per kw cooling capacity t 7K 123 l/h per kw cooling capacity t 8K 108 l/h per kw cooling capacity t 9K 96 l/h per kw cooling capacity t 10K 86 l/h per kw cooling capacity > In practice the cold water temperature difference is between 5 and 8K Which tube sizes and couplings are used for which cooling capacities? On the basis of acr experience, the following tubes and couplings can be used in the various different cooling capacity ranges, up to the maximum length of 100 meters. Cooling capacity Tube size Coupling < 20 kw DN 40 Storz C kw DN 50 Storz C kw DN 80 Storz B kw DN 100 Storz A > 800 kw DN 125 Storz 125 FAQ

146 FAQ - Refrigeration How is the cooling capacity affected by the soiling factor (Fouling Factor)? 146 Soiling factor [m² C / kw] Correction factor of the cooling capacity Correction factor of the power consumption Correction factor of the performance number (EER) For which operational areas are the air cooled chillers suited? The chillers are suitable for the unrestricted operation at 35 C outside temperature and operate in the capacity restricted mode in ambient temperatures up to 50 C. For use in lower ambient temperatures, the cold water chillers equipped with variable speed ventilators and vaporizer heating are suitable. In this way operation is possible at lower temperatures. At extremely low ambient temperatures and particular locations as well as when light cooling loads prevail, additional measures must be taken. Application area of air cooled chillers The sound values of the acr rental machines are specified at a distance of 5m. How much does the sound value decrease when the distance is doubled to 10m? Generally the sound pressure level is specified according to ISO 3744 in a hemispherical field at 1m distance. As a rule of thumb, the sound pressure is reduced by about 4 db(a) when the distance is doubled. For example a sound pressure level specification of 66dB(A) at 5m distance equates to a sound pressure level of about 62dB(A) at 10 meters, and at 20m about 58dB(A) and so on. FAQ

147 FAQ - Refrigeration Machine basics: Wherein do air cooled and water cooled chillers differ? Air cooled chillers (fluid cooler) distinguish themselves through their compact design and are available in a capacity range of 5 2,000kW. The refrigerant has a direct heat transition to the air and therefore the liquefaction of the refrigerant is directly passed through to the environment. Water cooled chillers are more efficient, however through an external drycooler unit they are also substantially more expensive and costlier to install. In the rental segment, the cooling capacity range is between 5 and 4,500kW per unit. 147 What is the difference between Scroll- and screw compressors? Because the compressor is an especially important part of a refrigeration unit, this question will be answered especially in detail. According to requirements and capacity range, scroll-, screw or centrifugal compressors are implemented. Scroll compressors are implemented in a capacity range of 5 100kW cooling capacity and are fully hermetically sealed. Several compressors can be used together in a refrigeration circuit. In this way capacity ranges of up to 600kW and more can be reached by the so-called Multiscroll units. The compression of the refrigerant is achieved by the orbital path of a moving spiral in a fixed spiral at about 2900 RPM at 50Hz. Fully hermetically sealed scroll compreessor (Danfoss) The current power adjustment herewith takes place by activating and deactivating individual compressors. In following example, four compressors provide for 100% cooling capacity. In the case of 85% loading, three compressors are continuously in operation and the fourth is engaged or disengaged as needed. To protect the compressor, the frequency of engaging / disengaging should not exceed six times per hour. > cold water temperature variations through engaging and disengaging of the compressor Compression principles in Scroll compressors (Bitzer) Betriebszyklus Scrollverdichter Semi-hermetic screw compressors are available in a capacity range of 100 1,200kW cooling capacity. With up to three separate refrigeration circuits, cooling capacities of over 2.000kW per unit can be achieved. The compression of the refrigerant is achieved by a continuous and on vibrating rotation of the screw at about 2,900 RPM at 50Hz. In the following photo, a McQuay single rotor screw compressor is shown. The single rotor screw compressor consists of a main rotor directly connected to the motor and two diametrically opposite, interrelated and geared addition rotors. The simultaneous flow of intake and compression leads to an almost complete cancellation of radial and axial forces and therefore to very slight bearing loads. FAQ

148 FAQ - Refrigeration 148 Semi-hermetical screw compressor Screw compressor functional principle The power adjustment of the screw compressor is step less. According to compressor size and number, a step less power adjustment up to 10% is possible. On the basis of the following example is to be recognized that at a load of about 85% the compressor can be set exactly. According to application or tolerated deviation of the cold water temperatures, this technology that enables an accuracy of ±0.2K ( C), is indispensable. Operational cycle screw compressor FAQ

149 FAQ: Air-conditioning 149 FAQ

150 FAQ - Air-conditioning Basics: 150 In which range does the so-called comfort zone lie? The cozy range, defines the comfort zone in a h, x-chart. The temperature should be between C and the relative humidity should be between 35-65%. Dependent on the starting point, it may be necessary, to heat, cool, dehumidify or to humidify. Which possibilities for air distribution exist? In general we distinguish between air transport and air distribution. For air transport, airtight tubes are used. In dependence of the necessary air volume and the tube length, acr chiller rent uses airtight tubes to transport air with the following diameters: Cozy range in the h, x chart (Lars Keller Leitfaden für Kompressionswasserkühlsätze) According to the following air resistance chart, the required air tube diameter can be determined dependent upon the air volume current (m3/min). Herewith is to be noted that the pressure loss is to the 2nd power to the volume current, i.e. a double volume current causes a fourfold pressure loss. FAQ

151 FAQ - Air-conditioning The air volume current of the mobile ventilation system can be divided according to requirement and request at the ventilation device. 151 Air distribution with single outlet Air distribution with double outlet For air distribution, porous textile air tubes are used. These are connected directly to the airtight tubes and distribute the relatively high air volume current uniformly over the room. Besides the draft-free air distribution, further advantages lie in the simple and fast placing as well as the optically impressive design. Typical air distribution variants by means of textile air tubes: Air distribution variants of textile air tubes Cooling capacity calculation: How is the cooling requirement of a room, hall or tent determined? In dependence of the room height, the geographic alignment, the insulation, the window areas as well as the number of people and other loads such as computers, the necessary cooling capacity needs to be observed individually. As a criterion, following experience values can be assumed Offices W/m3 Hall W/m3 Tents W/m3 FAQ

152 152 Heating - FAQ FAQ

153 FAQ - Heating Grundlagen: What is the COP value and how high is the average value for the air-water heat pumps? The EER (energy efficiency ratio) defines the performance number of a heat pump, i.e. the ratio of the heating produced to the consumption of electric energy. The acr heat pumps have an average COP value between 3.5 and How is the heating requirement of a room, hall or tent determined? In dependence of the room height, the geographic alignment, the insulation, the window areas as well as the number of people and computers, the necessary heating capacity needs to be observed individually. As a criterion, following experience values can however be assumed Offices W/m 3 Hall W/m 3 Tents W/m 3 Which advantages does an air-air heat pump offer compared a conventional directly fuelled heating system? The air-air heat pumps utilize the heat pump principle and the heating costs amount to about 50% of conventional heating. Only electric current is used to drive the pump and therefore no fuel supply is necessary. The acr heat pumps can have the circulation be switched to allow for heating as well as cooling with a single device. Under which conditions can air-air heat pumps be implemented without hesitation? Air-air-heat pumps withdraw energy from the outside air using the functional principle of a heat pump to transfer the comfortable warmth to the inner rooms of an office, tent or warehouse. This technology can be utilized at temperatures down to + 5 C without efficiency losses. Under colder conditions, the conventional acr heating systems are better suited. How different are air-air to air-water heat pumps? Air-air-heat pumps and air-water-heat pumps both use air as a heat source. In the air-air-heat pumps, the warmth carrier medium is air and a capacity of 30 to 120kW and at temperatures of + 15 to + 30 C can be covered. In the air-water-heat pump, the warmth carrier medium is water and a capacity of 10 to 500kW per unit and at temperatures of + 30 to + 50 C can be covered. If temperatures over 50 C are required, conventional heating systems should be used. FAQ

154 154 Power supply - FAQ FAQ

155 FAQ - Power supply Cable placing: Does one have to observe anything when laying a single conductor flexible cable? Power supply cables, that are longer than a 50 meters, inductive external conductor and earth end connections between the phases can cause considerable interferences e.g. an imbalance of the phase currents as well as an excessive voltage drop. Therefore the phase wires should be symmetrically arranged. 155 Placing 1-conductor, flexible cables How high is the maximally allowable voltage variation tolerance? In a three-phase-system, an excessive imbalance of the phases can lead to the overheating of the motor. The maximally allowable tolerance amounts to 3% and can be calculated as follows: Emergency power supply aggregates: How do I determine the necessary rated output of my emergency power supply aggregate? kva * 0,8 = Kilowatt ; kva = Ampere * 0,7 Is there a rule of thumb value for the fuel consumption of emergency power supply aggregates? Dependent on the aggregate type, following rule of thumb values can be assumed for the consumption. kva x 0,25 = l/h ; Ampere x 0,17 = l/h In which sizes are the fuel tanks of the emergency power supply aggregates available? Depending on which model, the tanks in the aggregate are integrated or available as a double-walled external addition tank with 1.200l, 2400l, 2750, 5,200 or l. Are larger plants and transformer stations available? On inquiry, emergency power supply aggregates designed as containers with up to 2,000kVA per unit can be delivered. Optionally transformers can be supplied for voltages of 500V to 20kVA. What is the difference between prp and ltp? Prp (prime power) indicates continuous capacity with variable loading at 100% rated output and ltp (limited time power) indicates the emergency power capacity at 110% rated output but only for maximally 1h per 24h. FAQ

156 156 Accessories und Einbindung FAQ

157 FAQ - Accessories and integration Connection systems (Storz, flange) Which connection systems are used as standard? Acr verwendet als Schnellkupplung sogenannte Storz-Kupplungen. Diese eignen sich bis zu einem Pressure range von 16bar sowie für Temperaturen von -15 C bis +90 C. Die Kupplungen sind symmetrisch aufgebaut, d.h. die zu kuppelnde Armaturen können beliebig verwendet werden. Die Größe der Kupplungen wird mit dem Zusatz C, B, A oder über den Abstand der beiden Klauen, auch Distance between claws genannt, definiert. Kupplungen mit gleichem Distance between claws sind untereinander kompatibel. 157 Storz-Kupplung Storz size Distance between claws Tube diameter 52-C 31 mm DN B 66 mm DN A 89 mm DN mm DN 125 How are the Storz couplings interconnected? The couplings are connected or disconnected by a 120 bayonet fastener. Optionally special types such as Storz flange connections are available. How can the rental refrigeration equipment be connected to a customer s flange connection? Acr has in its stores an extensive spectrum of couplings and connectors. So there are combined flange/storz-coupling adapters to all common flange and Storz connectors. A Storz coupling connection You can refer to the common flange sizes from the following table: Storz/Flange DIN PN 6 DIN PN 10/16 DN D k n d2 D k n d n = number of screw holes FAQ

158 FAQ - Accessories and integration Flexible hoses: In which sizes and lengths are the cold water tubes available and for which conditions are these suitable? 158 Flexible, acid resistant hoses from DN 40 to DN125 standard available and suitable for temperatures from minus 30 C to plus 80 C at an operating pressure of up to 10 bar. By simply connecting the individual tubes any length can easily be configured. The highly flexible tubes are easy to handle and distinguish themselves with their low weight per meter. Thanks to the quick couplings, intermediate pieces, and flange transition pieces, all connection variants and distributions can easily be implemented. Outside diameter Bend radius Weight Fill-up quantity (water in 4 C) [DN] [mm] [Zoll] [mm] [kg/m] [l/m] / ,3 1, ,9 2, / ,7 3, ,4 4, ,7 8, ,67 Cold water tube On the average how much pressure losses can be expected in the tubes? The pressure loss in the tube depends on various factors. Dependent on the fittings, the medium and the bend of the tubes the pressure loss can vary up to 50%. The pressure loss is in a 2nd power relationship to the current volume, i.e. at double current volume the pressure loss is fourfold. At a specified actual current volume and the tube diameter used, a more exact value can be calculated. The pressure loss chart serves as a guideline for the medium water in a tube length of 10m at room temperature. At temperatures below 4 C, the addition of an antifreeze is required. It has to be taken into consideration that this leads to an increased pressure loss. For longer tube connections, the values can be added up proportionally. Hose bends can account for a pressure drop of up to 50%. For fittings, a 5% pressure loss per fitting can be assumed as a rule of thumb. FAQ Pressure loss chart for a tube length of 10m and the medium being water)

159 FAQ - Accessories and integration Pumps- and pump modules What are the pump modules used for? The acr pump modules are used everywhere where fluids must be transported. Often the pump modules replace the integrated chiller replacements pumps, if the pressure losses are too high for the standard pumps based on the line lengths and less all other loads. In which variants are the pump modules available? The pumps are mounted as single or double pumps on a sturdy steel frame. Also attached is a control cabinet with all the electrical switching components. Extensive optional accessories such as three way valves, changeover valves, frequency converter, expansion tank, actuators, sound attenuation and weatherproof housing is available. 159 For which temperature ranges and in which capacity classes can the pumps be delivered? The capacity range of the pump modules extend from 2 m³/h up to 450m³/h and a pressure head up to 50m. Modules can be delivered for medium temperatures from minus 45 up to plus 120 C. Higher capacities and other temperature ranges can be provided upon request. How can the pump flow rate be adjusted? Dependent on the pump type, there are various possibilities. The acr standard pumps use either a throttling or Bypass control. The throttle regulation is installed on the pressure side between the pump and load. Through the throttling of the pump, the system resistance is increased and runs the pump with same rotation speed in diminished volume current and slighter clamp achievement. Scheme of the throttle regulation Throttle regulation The bypass controller is similar to the throttle regulation, however with an additional bypass way with a throttle fitting that is parallel to the pump. The pump transports at a constant speed the full flow at unchanged electrical power consumption. Schema Bypass control Bypass control FAQ

160 FAQ - Accessories and integration 160 Alternatively acr can provide VFD-pumps with variable speed regulation. The frequency converters are mounted and electrically cabled to the pump. The advantages lie in the possibility to adapt the flow rate and the head height by which means considerable energy can be saved. Next to the optimized process control, the reduction of sound emissions as well as a lower starting current is possible. Flow rate adjustment by way of variable speed pumps using VFD + Image Scheme speed regulation by means of VFD What does a plate heat exchanger do? Plate heat exchangers are made as soldered, welded or pressed designs. The acr system dividers are implemented anywhere where the separation between primarily and secondary circulation circuits is necessary due to different temperatures, different media or different pressures. The acr plate systems are available with heat exchanger plates made of stainless steel or titanium as well as for especially high pressures (up to 23 bar). acr plate heat exchanger What are hydraulics modules used for? A hydraulics module consists of a plate heat exchanger and an integrated pump. This module serves the separation between primarily and secondary circulation circuits and includes an additional pump. Further applications are different and/or higher temperature ranges and different pressures. acr hydraulics module For which use areas are the hydraulics modules available? The hydraulics modules can be used for medium temperatures from minus 45 up to plus 120 C and for flow rates of 2 m³/h to 180m³/h per module. For greater capacities, these can be arranged in parallel. FAQ Are there also heat exchangers suitable for extremely corrosive media? For extremely corrosive media such as salt-brine-mixture, acids and lyes, acr has plate heat exchangers made of titanium in the assortment.

161 FAQ - Accessories and integration Hydraulic integration: Which possibilities is there, to integrate the rental chiller hydraulically into the system? During hydraulic integration consideration must be taken into account that a constant flow rate is achieved through the chiller. This can be realized using a three way valve or a two way bypass valve. In a two way throttle valve, a differential pressure controlled bypass valve is to be installed, in order to guarantee that when the throttle is fully closed that a sufficient flow volume is still achieved over the vaporizer. Three way valve at the load (Lars Keller Leitfaden für Kompressionswasserkühlsätze) Two way valve at the load (Lars Keller Leitfaden für Kompressionswasserkühlsätze) 161 System separation by way of heat transfer (Lars Keller Leitfaden für Kompressionswasserkühlsätze) A further possibility is the use of a plate heat exchanger. Therewith the flow on the secondary side (chilleer) is constant and the regulation takes place on the primary side (load) usually by means of a gate valve and a speed regulated pump. Plate heat exchangers are used also to be able to have different media on the primary and secondary circuits. If several chillers are hydraulically integrated, a hydraulic switch is often used to decouple the primary and secondary circulation circuits. The primary flow rate must herewith always be greater or equal to the load flow rate. Hydraulic switch (Lars Keller Leitfaden für Kompressionswasserkühlsätze) Another linking variant is the buffer storage to increase the volume and compensation of partial and peak loads. The advantage lies therein that the compressors on off cycles are minimized as well as that the hydraulic network is stabilized. Buffer storage to enlarge the volume (Lars Keller Leitfaden für Kompressionswasserkühlsätze) FAQ

162 FAQ - Accessories and integration Flow detector: Which flow detectors are available from acr and how are these installed? 162 Flow detectors are installed in the cold water pipes in order to monitor the vaporizer flow rate and avoid a dry running pump or freezing of the vaporizer. The paddle flow detectors are integrated directly into the piping. The length of the paddle is adapted to the pipe dimension. Subsequently the sensitivity of the flow switch is set. The digital flow detector is the high-value and more meaningful flow detector variant. A branching line with a diameter of 6-10mm is connected to the differential pressure measuring instrument at one of the measurement locations (for example the vaporizer inlet or outlet). The pressure changes cause resistance changes and this is indicated by the integrated electronics. Paddle flow detector to monitor media flow Elektronic connections: What cabling is used for the rental machine? Digital differential pressure flow detector can only give cabling recommendations. The cable cross-sections and fuses should be examined and approved by a qualified local electrician before initial operation. The cable dimensioning is dependent on the cable type and cable laying style. FAQ Cable category Single conductor Multiple conductor Number of conductors Cross section Capacity in A 2,

163 FAQ - Accessories and integration Welche verschiedenen Anschlussmöglichkeiten für unsere Mietkältemaschine gibt es? Dependent on the machine type, there are three possible electrical connections for the rental machine. The smaller machines are equipped with a CEE connector and can be quickly and simply connected together. The CEE connectors are available in the sizes 16A, 32A, 63A and 125A. The style and the contacts are designed so that only the same sizes can be interconnected. CEE connector 163 Dependent on the machine size and the integrated main switch, wire end sleeves are used. In order to protect the stripped cable ends and to produce a flawless electrical contact, the end sleeves are placed over the cable ends and crimped with a special pair of pliers. Subsequently the individual conductors are clamped by a screw connection. Dependent on the cross-section, they are color coded. The cable terminals are connected to the conductor similarly to the wire end sleeves by way of a positive locking device. The cable terminals used are from 10mm² to 240mm². The contact and/or the connection between the clamp and the cable shoe results through the security of a metric screw. Wire end sleeves Cable terminal Up to what capacity range can a rental chiller be connected by a CEE connector? According to machine size, the machines in the smaller capacities can be connected with a CEE connector. The advantage lies therein that the connection is quick, safe and simple. In larger capacity ranges (> 150kW cooling capacity) the machines are connected with cables, whose endings have wire end sleeves or cable terminals. FAQ

164 FAQ - Accessories and integration Refrigerants, oils and heat carriers: Which different refrigerants are there and how are they different? 164 Basically the refrigerant carries the heat in the cooling circuit. Refrigerants are marked by a R (Refrigerant) and a three-digit number. Refrigerants are different in that the physical characteristics e.g. the enthalpy of vaporization, the volumetric cooling capacity and its pressure ratio, in its chemical characteristics such as corrosiveness, combustibility and the ecological characteristics such as the ozone damaging potential as well as the global warming potential. In the following table, the relevant data of different, current refrigerants are listed (source: Lars Keller Leitfaden für Kompressionswasserkühlsätze). Refrigerants and their physical characteristics (Solvay Fluor GmbH) - R134a R410A R407C R404A R507 R717 Volumetric cooling capacity 0 /40 kj/m Evaporation heat kj/kg Critical temperature C ,03 72,05 70, Absolute pressure at 0 C (p0) bar 2,93 8,06 5 6,1 6,29 4,29 Absolute pressure at 40 C (p0) bar 10,17 24,36 16,47 18,32 18,79 15,55 Differential pressure pc - p0 bar 7,24 16,3 11,47 12,22 12,5 11,26 Pressure ratio pc / po - 3,47 3,02 3,29 3 2,99 3,62 Temperature glide (0 /40 ) K 0 0 4,69/5,16 0,02/0, ODP GWP (relative to CO2, 100a) Practical limit (DIN EN 378) kg/m3 0,25 0,44 0,31 0,48 0,49 0,00035 In the acr chillers, the refrigerants used are predominantly R134a, R410a and R507. These safe refrigerants are not inflammable, non-toxic, non-polluting, environmentally friendly and very efficiently. Under which conditions is the use of a heat transfer medium in the system necessary and why? Heat transfer medium (antifreeze) prevents the freezing of water and prevents frost damage. Usually Monoethylen- as well as Propylenglykol are used. -> Glykol is used at water discharge temperatures 4 C. -> When using Glykol the flow quantity must be increased by about 10% so that the t (temperature difference) remains the same. -> At a Glykol content of 30% the system pressure loss is increased by about 20%. Pumps must be suited for the operation with Glykol; all pumps, tubes, heat exchangers and hydraulics modules are suited without restriction for this use. FAQ

165 FAQ - Accessories and integration What are the disadvantages of the use of brine? Positive and negative characteristics of brine (Lars Keller Leitfaden für Kompressionswasserkühlsätze) Positive characteristics Negative characteristics Low freezing point Poor heat transition Corrosion resistance if volume proportion is > 20% Higher pressure loss Higher thermal constancy Corrosive, when the proportion is < 20% Lower thermal constancy Limited durability, disposal necessary after use Hazard class WGK 1 Higher investment costs Exchange and disposal after service life 165 How does the heat carrier medium proportion behave dependent upon the fluid temperature? Antifreeze [ C] *Ethylen Glycol [Vol. %] * Der Anteil von Ethylen Glykol darf 20% nicht unterschreiten, da Mischungen mit geringen Anteil korrosive Eigenschaften haben können. Antifreeze [ C] *Ethylen Glycol [Vol. %] Can a water Glycol mixture be ordered from acr for the rental chiller? As required acr can deliver the necessary frost protection for your system. The mix ratio is determined depending on the available and/or necessary frost protection. FAQ

166 166 Machine commissioning - FAQ FAQ

167 FAQ - Machine commissioning What must be observed when installing air cooled chillers? In air cooled chillers the liquefaction of the refrigerant is accomplished with air, it is especially important that sufficiently with fresh air is available for the condenser registers on the sides of the chiller. To avoid heat accumulation or overheating it is especially important to keep the area clear of obstructions. 167 Setup: Assembly of air cooled chillers Which possibilities are there, to load and unload the air cooled chillers? According to machine size, the following are common variants to load and unload the rental chillers. > Up to 50kW = truck elevated stage + forklift > 50 to 600 kw = forklift > 600 kw = via mobile truck crane FAQ

acr chiller rent GmbH the profitable alternative. Rental products from acr the fast and reliable solution for your company.

acr chiller rent GmbH the profitable alternative.   Rental products from acr the fast and reliable solution for your company. Rental products from acr the fast and reliable solution for your company. Rental products Refrigeration / Air-conditioning Heating Power supply Accessories Specialty plants Used equipment market acr chiller

More information

Greater London Engineering Depot. Compound D Codham Hall, Great Warley Brentwood CM13 3JT

Greater London Engineering Depot. Compound D Codham Hall, Great Warley Brentwood CM13 3JT Advanced Cooling- Chiller Hire Fleet 2/2013 Rental Systems Available For; Process cooling Building Air conditioning Chilled water systems Low temperature refrigeration Ice rinks Events/film set cooling

More information

Industrial cooling systems LT

Industrial cooling systems LT Industrial cooling systems LT 01 Industrial cooling and heating. Partner of the industry for over 40 years. Since 1971 DELTATHERM has belonged to Hirmer GmbH, a family business with its headquarters in

More information

Product Catalog. Trane Rental Services Temporary HVAC Equipment, Oil-Free Air Compression, and Power Distribution SRV-PRC006B-EN.

Product Catalog. Trane Rental Services Temporary HVAC Equipment, Oil-Free Air Compression, and Power Distribution SRV-PRC006B-EN. Product Catalog Trane Rental Services Temporary HVAC Equipment, Oil-Free Air Compression, and Power Distribution July 2015 SRV-PRC006B-EN Introduction Emergency situation, planned maintenance, special

More information

F Series - Refrigeration dryers

F Series - Refrigeration dryers F Series - Refrigeration dryers Quality compressed Air Flows from 0,38 to 110 m 3 /min QUALITY, DRY COMPRESSED AIR: THE EFFECTS: Considerably reduced production costs. Circuit protected against corrosion.

More information

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C Product Data 30RQ Air-cooled Modular Chiller R22 & R410A & R407C Introduction Air-cooled modular chiller is a kind of central airconditioning unit which adopts air as the cooling (or heating) source and

More information

ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS

ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS ACCENT AIR WATER TO WATER COMMERCIAL HEAT PUMPS CONTENTS Overview 2 Features & Benefits 3 Performance 4 Accent Pool Water to Water Heat Pumps Technical 5 Accent Hot Water Water to Water Heat Pumps Technical

More information

50A KP 70A KP 90A KP 120A KP 150A KP 210A

50A KP 70A KP 90A KP 120A KP 150A KP 210A DC inverter all in one Model KP 5A KP 7A KP 9A KP 12A KP 15A KP 21A Power supply V/Hz/Ph 23/5/1 23/5/1 23/5/1 23/5/1 38/5/3 38/5/3 Nominal heating capacity kw 5 7 9 12 15 21 Nominal cooling capacity kw

More information

Trane Rental Services. Temporary cooling and heating solutions

Trane Rental Services. Temporary cooling and heating solutions Trane Rental Services Temporary cooling and heating solutions Whether for an emergency or a planned event, Trane is there to help you Whether it s extra cooling or heating that is needed during extreme

More information

AQUAHEAT ADVANCE SPLIT

AQUAHEAT ADVANCE SPLIT AQUAHEAT ADVANCE SPLIT HEAT PUMP INVERTER SPLIT SYSTEM AN AIRWELL GROUP COMPANY Indoor unit Outdoor unit 005 PRODUCT ADVANTAGES INVERTER technology R4A refrigerant 2 versions available: heating only /

More information

TEMPERATURE CONTROL POWER COMPRESSED AIR EMERGENCY OR PLANNED, SHUT DOWN OR TURN AROUND. 24/7/ / ers-cat.com

TEMPERATURE CONTROL POWER COMPRESSED AIR EMERGENCY OR PLANNED, SHUT DOWN OR TURN AROUND. 24/7/ / ers-cat.com TEMPERATURE CONTROL POWER COMPRESSED AIR EMERGENCY OR PLANNED, SHUT DOWN OR TURN AROUND 24/7/365 877.291.3354 / ers-cat.com TEMPERATURE CONTROL CHILLERS Available in 30 to 1000-ton capacities Air cooled

More information

Hot Water Heating Systems

Hot Water Heating Systems Hot Water Heating Systems Find out more at www.greeonline.com Key Wide Range of Operation Conditions Heating -26 C 46 C Features The Ultra Hot Water system is specifically designed to be flexible in its

More information

GENERAL INFORMATIONS

GENERAL INFORMATIONS GENERAL INFORMATIONS Devices only operate in cooling mode. Enviromental-friendly R407c coolant is utilized in standard products. The system can be created with various coolants depending on the water temperature

More information

AUSTRALIA PACIFIC. Cooling and Heating Guide

AUSTRALIA PACIFIC. Cooling and Heating Guide AUSTRALIA PACIFIC Cooling and Heating Guide Aggreko engineers have vast experience designing and delivering commercial cooling and heating packages across a range of industries Enabling business improvements

More information

PACKAGED REFRIGERATION EQUIPMENT

PACKAGED REFRIGERATION EQUIPMENT PACKAGED REFRIGERATION EQUIPMENT BUYER S GUIDE WHAT TO LOOK FOR WHEN SELECTING LOW-CHARGE PACKAGED REFRIGERATION EQUIPMENT for your facility 2 Packaged Refrigeration Equipment Buyer s Guide What to look

More information

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT 90% EFFICIENCY HIGHEST EFFICIENCY AIR HANDLING UNIT Packaged energy recovery solutions for Green Buildings Integrated Accumulator, controls and DX Cooling System CLEAN AIR SINCE 1963 Euroclima is a company

More information

REFRIGERATOR P H A R M A C Y.

REFRIGERATOR P H A R M A C Y. P H A R M A C Y REFRIGERATOR www.labocon.com NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation. PHARMACEUTICAL REFRIGERATOR LRP-100 SERIES

More information

An Introduction of Below-Freezing and Humidity Environment Controlling Technology Equipped on Brake Test Equipment

An Introduction of Below-Freezing and Humidity Environment Controlling Technology Equipped on Brake Test Equipment Technical Report An Introduction of Below-Freezing and Humidity Environment Controlling Technology Equipped on Brake Test Equipment Hironobu Kurara, Custom Equipment Engineering Department 2, Custom Equipment

More information

Temporary HVAC Equipment, Oil-Free Air Compression and Power Generation

Temporary HVAC Equipment, Oil-Free Air Compression and Power Generation RENTAL SERVICES Temporary HVAC Equipment, Oil-Free Air Compression and Power Generation Whether an emergency or planned event, Trane is there. Whether it s extra cooling needed during extreme weather conditions

More information

SWIMMING POOL HEAT PUMPS

SWIMMING POOL HEAT PUMPS WHAT IS A POOL HEAT PUMP? Swimming pool heat pumps extract the heat stored in the ambient air and transfer it to water. It increases the water temperature to reach the desired level. Comparatively, it

More information

ICS COOL ENERGY B.V. Specialist Provider of Hire Process Heating and HVAC Equipment

ICS COOL ENERGY B.V. Specialist Provider of Hire Process Heating and HVAC Equipment ICS COOL ENERGY B.V. Specialist Provider of Hire Process Heating and HVAC Equipment Heating, Hot Water and Domestic Hot Water Hire Heating capacities 3kW 1.3MW single units and Multi-Megawatt Packages

More information

Modular Air Cooled Scroll Chillers

Modular Air Cooled Scroll Chillers Modular Air Cooled Scroll Chillers 65 80 130 Find out more at www.greeonline.com 160 249 High Efficiency Shell and Tube Heat Exchanger The Gree D Series Chillers utilise high efficiency shell and tube

More information

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION SWIMMING POOL DEHUMIDIFICATION SWIMMING POOL Dehumidification systems for private indoor swimming pools, Dehumidification for swimming pools, hotels, spas or therapeutic clinics spas and therapeutic clinics

More information

QUANTUM. Series and features of the energy-efficient chiller series

QUANTUM. Series and features of the energy-efficient chiller series QUANTUM Series and features of the energy-efficient chiller series Optimal use of energies. engie-refrigeration.de INTRO Impressive performance: QUANTUM For chilling: QUANTUM It starts smoothly, then runs

More information

Technical description. Atec.

Technical description. Atec. www.thermia.com Thermia Värmepumpar is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language is used for the original instructions.

More information

Performance Data ADSORPTION CHILLER AGGREGATES & SYSTEM COMPONENTS

Performance Data ADSORPTION CHILLER AGGREGATES & SYSTEM COMPONENTS Performance Data ADSORPTION CHILLER AGGREGATES & SYSTEM COMPONENTS 05/2017 2 Picture credits: Fotolia.com ( industrieblick, Kenishirotie, surawutob, gmstockstudio). Content ADSORPTION CHILLER AGGREGATES

More information

Heat Exchangers. Tailor made heat exchangers solutions at home in all fields.

Heat Exchangers. Tailor made heat exchangers solutions at home in all fields. Heat Exchangers Tailor made heat exchangers solutions at home in all fields. Tailor made heat exchangers solutions at home in all fields Ipros Heat Exchangers segment in partnership with the world recognized

More information

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions TECHNICAL DATA SHEET HP08L-M-WEB Performance Data 1) A-7W35 A2W35 A10W35 A2W50 Heating capacity 8,67 kw 11,14 kw 14,91 kw 9,87 kw Cooling capacity 6,16 kw 8,58 kw 12,33 kw 6,43 kw Input 2,51 kw 2,56 kw

More information

Process glycol chillers

Process glycol chillers Process glycol chillers The most advanced solutions in refrigeration technology. According to normative EN378 y F-Gas Compact chillers for outdoor installation Natural refrigerant Integrated hydraulic

More information

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw PROCESS CHILLERS AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com PROCESS CHILLERS MAXIMUM EFFICIENCY IN EVERY TYPE OF PROCESS APPLICATION Air cooled liquid chiller for outdoor

More information

Air-cooled Screw Chillers Model RTAF G Process

Air-cooled Screw Chillers Model RTAF G Process Air-cooled Screw Chillers Model RTAF G Process Near 0 GWP (

More information

Product Data Sheet Refrigeration Dryer DFLO 66 (-W) bis DFLO 2400 (-W)

Product Data Sheet Refrigeration Dryer DFLO 66 (-W) bis DFLO 2400 (-W) Refrigeration Dryer 66 (-W) bis 2400 (-W) Version: 1.0.1 Author: Karsten Unger Date: 20.09.2013 Field of application Refrigeration dryers of the series are designed for drying compressed air flows up to

More information

Ingersoll Rand. Rotary Screw Air Compressors 5-15 hp (4-11 kw)

Ingersoll Rand. Rotary Screw Air Compressors 5-15 hp (4-11 kw) Ingersoll Rand Rotary Screw Air Compressors 5-15 hp (4-11 kw) A New Standard of Performance Ingersoll Rand Welcome to Ingersoll Rand s rotary air solutions, a new standard of performance. Achieve highest

More information

HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER

HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER HIGH TEMPERATURE AIR SOURCE HEAT PUMP WATER HEATER BIGGER-H SERIES JIAXING MES NEW ENERGY TECHNOLOGY CO.,LTD. High quality- We believe that quality is the best business plan R&D team- Professional R&D

More information

Powerful and reliable. Also for high ambient temperatures. weco Compact chillers

Powerful and reliable. Also for high ambient temperatures. weco Compact chillers Powerful and reliable. Also for high ambient temperatures. weco Compact chillers The smart approach to cooling. Energy-effic Innovative technology The new compact chillers are equipped according to the

More information

Air conditioners Cooling only

Air conditioners Cooling only Air conditioners Rooftop, an economical solution for medium to large spaces Plug and play for easy installation High efficiency Quick cooling Wide operation range Compact unit www.daikinme.com UAT-CGXY

More information

Refrigeration dryers DW 2-504

Refrigeration dryers DW 2-504 DW Refrigeration dryers DW 2-504 Worthington Creyssensac s heritage Creyssensac was founded in Nanterre (near Paris), France in 1934 by Elie Creyssensac and quickly became renowned in the automotive industry

More information

Air Conditioning System

Air Conditioning System For continual product development, LG reserves the right to change specifications without notice. LG MULTI V Air Conditioning System 200 Air Conditioning System 200 Air Conditioning System Enjoy a clean

More information

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING Free cooling modules for 2 700V to 1100V POWER 1200V to 1800V Cooling capacity: 185 to 485 kw Cooling only Hydraulic module Free cooling ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT

More information

HVAC SYSTEMS COMMERCIAL VESSELS

HVAC SYSTEMS COMMERCIAL VESSELS HVAC SYSTEMS COMMERCIAL VESSELS 2 INTRODUCTION 3 A team of technical climate control experts with over twenty five years experience in the specialist mobile markets, (marine, automotive, military, and

More information

Inverter Ducted Air Conditioners

Inverter Ducted Air Conditioners Inverter Ducted Air Conditioners About Carrier inverter ducted systems Carrier s Inverter Ducted systems allows you to air condition your home without having to install the indoor units on your wall, making

More information

AMONUM chillers. Eco-friendly cooling in compact packaging, easy maintenance and safe. Optimal use of energies. engie-refrigeration.

AMONUM chillers. Eco-friendly cooling in compact packaging, easy maintenance and safe. Optimal use of energies. engie-refrigeration. AMONUM chillers Eco-friendly cooling in compact packaging, easy maintenance and safe. Optimal use of energies. engie-refrigeration.de INTRO AMONUM chillers are efficient, compact and natural Ammonia is

More information

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING 171 water cooled chillers / heat pumps and motoevaporating units COOLING HEATING R410A 1 96 3 2 0 1 3 f i f t y c o o l y e a r s RCGROUP SpA 19632013 fiftycoolyears PLATE 5,4 30,5 kw 6,4 37,4 kw 172 VERSIONS

More information

ICS COOL ENERGY B.V. Specialist Provider of Hire Process Heating and HVAC Equipment

ICS COOL ENERGY B.V. Specialist Provider of Hire Process Heating and HVAC Equipment ICS COOL ENERGY B.V. Specialist Provider of Hire Process Heating and HVAC Equipment Heating, Hot Water and Domestic Hot Water Hire Heating capacities 3kW 1.3MW single units and Multi-Megawatt Packages

More information

Environmentally friendly refrigeration systems for industrial use

Environmentally friendly refrigeration systems for industrial use compindustri Environmentally friendly refrigeration systems for industrial use CO ² refrigeration systems of the future GENERAL INFORMATION compindustri More than 10 years of development of refrigeration

More information

Choose the winning team. Heat transfer technology for industrial cooling and air conditioning

Choose the winning team. Heat transfer technology for industrial cooling and air conditioning Choose the winning team Heat transfer technology for industrial cooling and air conditioning Alfa Laval makes it easy Buying heat exchange components for industrial cooling and air conditioning projects

More information

SERVICE ASSISTANT OVERVIEW FDSI Online Training

SERVICE ASSISTANT OVERVIEW FDSI Online Training Author: Dale T. Rossi Online Editor: Zachary Williams SERVICE ASSISTANT OVERVIEW FDSI Online Training May 5, 2009 Table Service Assistant Description... 2 Installing the Main Unit... 3 Ambient Temperature...

More information

Oilon Ground Source Heat Pumps

Oilon Ground Source Heat Pumps Oilon Ground Source Heat Pumps Homes - Large properties - Industry Ground source heat pump Oilon CUBE For properties 90-400 m² Extremely high domestic hot water production The Oilon CUBE ground source

More information

Data Centre Cooling Solutions

Data Centre Cooling Solutions Data Centre Cooling Solutions DIGITAL REVOLUTION In 2016 we produced as much data as in the entire history of humankind through 2015. POWER NEEDS It is estimated that 1,5% of globally generated power is

More information

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF

New CGAF Air Cooled Scroll Chiller. New Air-Cooled Scroll Chiller CGAF New CGAF New Air-Cooled Scroll Chiller CGAF New CGAF CGAF Air cooled Scroll Chiller 170 700 kw Cooling Only CXAF 150 700 kw Heat pump Coming soon 2 New addition to the Sintesis Family: Multiple technologies,

More information

AIR SOURCE HEAT PUMPS DUAL CLIMA

AIR SOURCE HEAT PUMPS DUAL CLIMA AIR SOURCE HEAT PUMPS DUAL CLIMA COMPACT MONOBLOC HEAT PUMP COMPLETE INSTALLATION SOLUTION PACK (HEATING, COOLING AND DHW) FULLY RATED HEATING CAPACITY GUARANTEED TO -20ºC CAN BE COMBINED WITH OTHER ENERGIES

More information

Data Centre Cooling Solutions

Data Centre Cooling Solutions Data Centre Cooling Solutions Heat Exchange Solutions ThermoKey DIGITAL REVOLUTION In 2016 we produced as much data as in the entire history of humankind through 2015. POWER NEEDS It is estimated that

More information

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit HRV-IP Ceiling Type Heat Pump Heat Recovery Unit HRV-IP Ceiling Type Heat Pump Heat Recovery Unit Ceiling type heat pump heat recovery units are energy saving devices thanks to plate type heat exchanger

More information

Air Cooled Packaged Systems AIRAH Back to Basics

Air Cooled Packaged Systems AIRAH Back to Basics Air Cooled Packaged Systems AIRAH Back to Basics What s changed? New Refrigerants R410a MEPS EER / AEER / SEER Manufacturing Technologies Research, Development and Testing New technologies, controls, reliability

More information

PRODUCT GUIDE

PRODUCT GUIDE PRODUCT GUIDE 01.2017 Cooling Heating CHAPTER 1 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Power (kw) Page IACAK/II/WP 101.5 106 0 58 115 A CLASS energy efficiency

More information

echiller R718 refrigeration system

echiller R718 refrigeration system echiller R718 refrigeration system The echiller is the only chiller worldwide that uses water (R718) as refrigerant, is manufactured in series production, and is based on an innovative technology that

More information

Ingersoll Rand. Refrigerated Air Dryers

Ingersoll Rand. Refrigerated Air Dryers Ingersoll Rand Refrigerated Air Dryers Reliable, Efficient, Low Cost of Ownership Ingersoll Rand Providing clean, dry, compressed air is especially important in applications where moisture or contamination

More information

Laird Thermal Systems Application Note. Bi-directional Microcontrollers Monitor and Protect Medical Equipment

Laird Thermal Systems Application Note. Bi-directional Microcontrollers Monitor and Protect Medical Equipment Laird Thermal Systems Application Note Bi-directional Microcontrollers Monitor and Protect Medical Equipment Contents Overview...3 Thermal Management Technologies...3 Design Example...3 Thermoelectric

More information

Product Data Sheet Refrigerant Dryer DFLO-ES 66 (-W) to DFLO-ES 660 (-W) with energy saving management

Product Data Sheet Refrigerant Dryer DFLO-ES 66 (-W) to DFLO-ES 660 (-W) with energy saving management Product Data Sheet Refrigerant Dryer -ES 66 (-W) to -ES 660 (-W) with energy saving management Version: 1.6.0 Author: Karsten Unger Datum: 05.07.2016 Field of application Refrigeration dryers of the -ES

More information

INVERTER DUCTED SYSTEMS

INVERTER DUCTED SYSTEMS INVERTER DUCTED SYSTEMS What you ll find inside: DC Twin-Rotary Compressor Inverter Ducted advantages Controllers Product Specifications Energy Efficient Powerful Operation Flexible Application 1 About

More information

ReCooler Heat-Pump Energy efficient cooling unit for eq Air Handling Unit

ReCooler Heat-Pump Energy efficient cooling unit for eq Air Handling Unit ReCooler Heat-Pump Energy efficient cooling unit for eq Air Handling Unit 28 May 2013 Agenda Introduction to Fläkt Woods Our Product Solution Technical Features Benefits Fläkt Woods Index We save energy!

More information

PHOENIX PNX DCI WALL MOUNTED RANGE AN AIRWELL GROUP COMPANY

PHOENIX PNX DCI WALL MOUNTED RANGE AN AIRWELL GROUP COMPANY PHOENIX PNX DCI AN AIRWELL GROUP COMPANY OUTDOOR UNIT GC 9-12-18 DCI OUTDOOR UNIT GC 21 DCI OUTDOOR UNIT GC 24 DCI RC4 (Actual consumption will depend on how the appliance is used and climate) Ful load

More information

Outdoor Condensing Unit - ZX Range. High Efficiency In Compact Design

Outdoor Condensing Unit - ZX Range. High Efficiency In Compact Design Outdoor Condensing Unit - ZX Range High Efficiency In Compact Design Outdoor Condensing Unit - ZX The Best Choice For Small Retail And Food Service Applications The new generation of Copeland EazyCool

More information

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps Chillers Air cooled multi-scroll chillers and heat pumps High efficiency values both in cooling and heating mode Extremely wide operating range, outside ambient temperatures up to 52 C One or two refrigerant

More information

HIRE PROCESS COOLING AND HVAC EQUIPMENT

HIRE PROCESS COOLING AND HVAC EQUIPMENT HIRE PROCESS COOLING AND HVAC EQUIPMENT COOLING CAPACITIES 0.3KW - 1.25MW SINGLE UNITS AND MULTI-MEGAWATT PACKAGES WE ARE ICS COOL ENERGY FULL TURNKEY TEMPERATURE CONTROL SOLUTIONS THROUGHOUT UK & EUROPE

More information

You can count on us...

You can count on us... You can count on us... Quality of air means quality of life Version 3/ 2018 Recirculating air cooling units Compact solutions for e.g. sever rooms with integrated mechanical cooling system or cold water

More information

New Bitzer factory: Higher precision with air conditioning

New Bitzer factory: Higher precision with air conditioning New Bitzer factory: Higher precision with air conditioning Central cooling unit for cutting oils and cooling lubricants replaces 25 decentralised coolers Air-cooled direct condensers from the GVH series

More information

Just feel well. 2017/2018 Air conditioning

Just feel well. 2017/2018 Air conditioning 1947-20 17 2017/2018 Air conditioning Unique solutions 40 Unique and advanced design for vertical or horizontal installation VERTICAL INSTALLATION q Vertical installation with compact dimensions, only

More information

WATE R -C OOLE D WATE R C H ILLE R S

WATE R -C OOLE D WATE R C H ILLE R S WATE R -C OOLE D WATE R C H ILLE R S R40A / R407C / R Standard Type Heat Recovery Type Brine Type ISO 900 ISO 400 Printed in Japan (H) HR-E590S Sep. 0 Water-cooled Chillers Advanced air conditioning solutions

More information

Be sustainable while protecting your business

Be sustainable while protecting your business Be sustainable while protecting your business Aquaflair 50Hz Air-cooled chillers and free-cooling chillers with double screw compressors and HFO R1234ze refrigerant (400V/3ph/50Hz) 300-1000 kw Aquaflair

More information

Mobile Energy Units Hire Sale Lease

Mobile Energy Units Hire Sale Lease Mobile Energy Units Hire Sale Lease We deliver energy where it s needed. MOBILE HEATING UNITS MOBILE Chiller UNITS Our heating units are high-quality, high-performance mobile energy sources. With an output

More information

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h Comfort air conditioning 76 Comfort air conditioning unit with counterflow plate heat exchanger Automatically selects the most economical operating mode! 76 13 76 01 13 with 01 - Adiabatic simplified Pro

More information

Flexible & Innovative. Cooling Solutions

Flexible & Innovative. Cooling Solutions Flexible & Innovative Cooling Solutions Flexible & Innovative Compu-Aire Inc. offers a variety of high performance precision cooling systems that can adapt to your application needs. With today s rapidly

More information

RIGID DC LIQUID CHILLER

RIGID DC LIQUID CHILLER RIGID DC LIQUID CHILLER Phone: +86-579-8837-9768 Email:info@rigidhvac.com Website: www.rigidchill.com 1 1. WHAT S LIQUID CHILLER? Liquid Chiller cooling refers to cooling by means of the convection or

More information

Hi-Pres Cooling Products Catalogue. Product Catalogue

Hi-Pres Cooling Products Catalogue. Product Catalogue Hi-Pres Cooling Products Catalogue Product Catalogue Important Notice This document is provided As is and is subject to change without prior notice. Novenco A/S reserves this right due to continuous product

More information

Emerson Superheat Control. The smart solution for your application

Emerson Superheat Control. The smart solution for your application Emerson Superheat Control The smart solution for your application Trust in Emerson Climate Technologies for reliable, precise and efficient superheat control. When it comes to superheat control, Emerson

More information

LAF 50 / 100 / 150. Condensing dehumidifiers for professional use. Accessories. Design. Approvals LAF

LAF 50 / 100 / 150. Condensing dehumidifiers for professional use. Accessories. Design. Approvals LAF LAF Dehumidifiers LAF D e h u m i d i f i e r s LAF 50 / 100 / 150 Condensing dehumidifiers for professional use VEAB condensing dehumidifiers are designed for professional use in application in which

More information

g in n io it d n Co AirnioisCe prmo roretupm Co made in italy

g in n io it d n Co AirnioisCe prmo roretupm Co made in italy made in italy C o m p u t e r Room Precision A i r Conditioning C.M.C. GROUP METAL STRUCTURAL WORK : STEEL, STAINLESS STEEL, ALUMINIUM ALLOY AIR CONDITIONING SYSTEM Product Range CC Close Control Air Conditioners

More information

Outdoor Refrigeration Unit - ZX Range High Efficiency In Compact Design

Outdoor Refrigeration Unit - ZX Range High Efficiency In Compact Design Outdoor Refrigeration Unit - ZX Range High Efficiency In Compact Design Outdoor Refrigeration Unit - ZX The Best Choice For Small Retail And Food Service Applications The new generation of Copeland EazyCool

More information

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: , DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: +971-6-5432526, Fax#: +971-6-5432415, Email: dolcool@emirates.net.ae, web site: www.dolphinheattransfer.com NOMENCLATURE: INTRODUCTION DOLCOOL branded

More information

UltraPleat Technology BURAN REFRIGERATION COMPRESSED AIR DRYER

UltraPleat Technology BURAN REFRIGERATION COMPRESSED AIR DRYER UltraPleat Technology BURAN REFRIGERATION COMPRESSED AIR DRYER Plug & Play Design There is more to Compressed Air than just Compressing Air Compressed air is an indispensable source of operating and processing

More information

RESIDENTIAL HIGH TEMPERATURE WATER SOURCE HEAT PUMP WATER HEATER

RESIDENTIAL HIGH TEMPERATURE WATER SOURCE HEAT PUMP WATER HEATER RESIDENTIAL HIGH TEMPERATURE WATER SOURCE HEAT PUMP WATER HEATER GROUND-RH SERIES JIAXING MES NEW ENERGY TECHNOLOGY CO.,LTD. High quality- We believe that quality is the best business plan R&D team- Professional

More information

Ultimate energy saving technology

Ultimate energy saving technology Ultimate energy saving technology CWT Chiller Series CWt purestream series water chillers The new CWT Purestream chiller range is specifically designed to meet the stringent cooling requirements of today

More information

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES Water to water chillers and heat pumps The water chillers range have been designed for small and medium residential and commercial applications. The water chillers are suitable for water outlet temperatures

More information

RoofPak Applied Rooftop Systems

RoofPak Applied Rooftop Systems RoofPak Applied Rooftop Systems RoofPak Applied Rooftop Systems Design flexibility, energy efficiency, system performance and reliability make Daikin RoofPak applied rooftop systems the ideal solution

More information

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University AIR-CONDITIONING SYSTEMS AND APPLICATIONS Abdullah Nuhait Ph D. King Saud University AIR-CONDITIONING SYSTEMS Earliest air conditioning system used only for heating (winter) Provided heated air for comfort

More information

Air Cooled Scroll Chiller

Air Cooled Scroll Chiller Air Cooled Scroll Chiller Midea chillers use H shape heat at air side and single unit s capacity from kw to 0kW. Super chillers are divided to SS,SS-LA, SP-LA and SP-HMLA series according to their water

More information

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES Air to water chillers and heat pumps The water chillers range is an efficient and low-noise product designed for medium to big applications. The water chillers are suitable for water outlet temperatures

More information

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection NC NC Series NG NG Series Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection NC NC SERIES PERFORMANCE DATA Model Capacity Min. Circuit Ampacity (MCA)

More information

Capacity kw G SERIES. Value range of general-purpose industrial chillers

Capacity kw G SERIES. Value range of general-purpose industrial chillers Capacity 1.8-208 kw G SERIES Value range of general-purpose industrial chillers Aqua Cooler is a proudly Australian-owned and -operated industrial process chiller and drinking water cooler supplier. With

More information

Order by phone Order on-line Order by fax Website

Order by phone Order on-line  Order by fax Website LABOROTA 4000 Series, Rotary Evaporators The LABOROTA 4000 series comprises the LABOROTA efficient models, the LABOROTA digital models and the LABOROTA control models; all are available with either handlift

More information

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure. Refrigerant valves Valves for precise control and optimum energy efficiency in refrigeration systems Answers for infrastructure. MVL661.. MVS661..N and matching ASR valve insert The new generation MVL661..

More information

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw COMFORT CHILLERS AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com COMFORT CHILLERS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air-cooled liquid chiller for outside installation

More information

ShuttleAIRE Systems. A complete range of HVAC systems for small and medium sized vehicles.

ShuttleAIRE Systems. A complete range of HVAC systems for small and medium sized vehicles. ShuttleAIRE Systems A complete range of HVAC systems for small and medium sized vehicles. ShuttleAIRE Systems Thermo King offers a complete ShuttleAIRE product line to meet a wide range of applications,

More information

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating 2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER AIR-TO-WATER HEAT PUMP cooling - heating MINI CHILLER Highly efficient heat pump for summer and winter air conditioning. Ideal for residential and commercial

More information

Natural geothermal energy

Natural geothermal energy Natural geothermal energy ROTEX HPU ground the ground source heat pump that heats with free geothermal energy. Compact, environmentally responsible and uniquely efficient. L A ++ A Scale space heating

More information

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY Easy and fast installation Hydronic module available Compact, reliable and efficient Nominal cooling capacity : 8-40 kw Nominal heating capacity : 17-40 kw 50 410A Cooling or heating USE The air-to-water

More information

Split Portable Air Conditioner

Split Portable Air Conditioner SP-IOM-1 Please read and save this manual. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information.

More information

MODUCEL KW DOWNFLOW COOLING DRU DRU DATA ROOM UNITS

MODUCEL KW DOWNFLOW COOLING DRU DRU DATA ROOM UNITS MOUEL 80-10 KW OWNFLOW OOLING RU RU T ROOM UNITS T ROOM UNITS The Moducel range of high efficiency ata Room Units, are designed for high density load areas where a large cooling duty is required from a

More information

HVS, Hydro Variable System Air cooled chiller

HVS, Hydro Variable System Air cooled chiller HVS, Hydro Variable System Air cooled chiller YDCC522H (-C) / YDCC972H (-C) / YOCC762H (-C) / YOCC1522H (-C) A complete range from 15 kw up to 72 kw Water Systems Features Variable capacity compressor

More information