Swimming Pool Heat pump Instruction manual Harmo PAC series (Type ZVWX1017, ZVWX1023, ZVWX1033, ZVWX1042, ZVWX1052, ZVWX1057, ZVWX1062)
|
|
- Jason Leon Singleton
- 5 years ago
- Views:
Transcription
1 Swimming Pool Heat pump Instruction manual Harmo PAC series (Type ZVWX1017, ZVWX1023, ZVWX1033, ZVWX1042, ZVWX1052, ZVWX1057, ZVWX1062) Imported by : Zwembad BVBA Industrieweg Boortmeerbeek België 1
2 Table of contents Introduction... 3 Characteristics... 3 Safety instructions... 3 Specifications... 4 Installation... 5 Accessories needed for the installation... 5 Location... 5 Distance... 6 Installation of the pool system... 7 Installation of the bypass... 7 Electrical wiring... 8 Start-up procedure... 8 Condensation... 8 Guidelines... 8 Water chemistry... 8 Winter-ready... 9 Spring start-up... 9 Owner inspection... 9 Display settings Clock settings Timer settings Functions of the display Current status Maintenance Appendix
3 Introduction Read the manual carefully before you open or maintain the heat pump. The manufacturer of this product will not be held responsible for injuries or damage to the unit, as a result of improper installation, debugging or unnecessary maintenance. It is essential that the instructions of this manual are followed at all times. Qualified personnel must install the heat pump. Only a qualified installer, center, personnel or an authorized dealer, should repair the heat pump. Maintenance and operation must be carried out according to the recommended time and frequency, as mentioned in this manual. Use original standard spare parts only. Failure to comply with these recommendations will you re your warranty. Characteristics Durable: the heat exchanger is made of PVC & Titanium, which can withstand prolonged exposure to water. Easy operation: the heat pump is very easy to use: turn the heat pump on and set the desired water temperature. Silent operation: the intelligent LCD display allows you to set the perfect temperature. Low cost: the operational cost is very low compared to the high performance of this heat pump. Safety instructions Place the heat pump at a safe distance. Never place the pump within a radius of 350 cm from the pool. The heat pump can be mounted with an RCD safety plug. Put the RDC plug directly and solely into an earthed socket. Never use an extension cord or similar. Check the voltage on the plug to the power at the socket. Only use an earthed socket. Always check that the safety plug is working properly to ensure safety. Never remove the safety plug. Place the pump and plug in a dry location. The heat pump is splash proof. The failure to comply with these instructions could result in serious injuries. 3
4 Safety test 1. Use the wiring diagram in the manual. 2. Plug into the socket. 3. Press the RESET button. The indicator "ON" is highlighted. 4. Press the "TEST" button. The indicator "ON will be turned off. 5. Press the RESET button in order to use the device. Do not use if above test fails. Specifications Product code: ZVWX1017 ZVWX1023 ZVWX1033 ZVWX1042 ZVWX1052 ZVWX1057 ZVWX1062 Product type: MONO MONO MONO Vertical/MONO Vertical/MONO Vertical/TRI Vertical/TRI COP 27 T air 27 T water Minimum outside temperature Heating Capacity (kw) 27 air/ 27 water Nominal power consumption (A) 5,1 7,3 9,5 13, ,5 12,4 Nominal water flow rate (m³ / h) 3 to 5 5 to 7 6 to 8 8 to to to to 13 Heat exchanger Titanium Titanium Titanium Titanium Titanium Titanium Titanium Airflow (m³/h) KW Connection (mm) Control panel Digital Digital Digital Digital Digital Digital Digital Compressor (number) Ventilators db RPM ventilator Weight Compressor Rotary Rotary Rotary Scroll Scroll Scroll Scroll Volt 230V 230V 230V 230V 230V 380V 380V 4
5 Installation Accessories needed for the installation The factory only provides the heat pump. Other necessary items that could be mentioned in the illustrations are to be provided by the user or installer. Attention! Please follow the following steps when installing the heat pump: The chemicals have to be added downstream of the heat pump. It is recommended to install a bypass when the flow of the pool pump is more than 20% of the rated flow of heat exchanger from the heat pump. Install the heat pump on a solid foundation and use rubber below the heat pump to eliminate vibrations and noise. Installeer de warmtepomp op een solide basis en gebruik de dempende rubber om het geluid en de vibratie te elimineren. Keep the unit straight up at all times. When the unit has been tilted, it is required to wait 24 hours before restarting the heat pump. The heat pump can be installed practically anywhere outdoors. If you wish to install it indoors, please contact your supplier. Location The heat pump can be installed practically anywhere outdoors. DO NOT place the unit in a closed area with a limited air volume where the air discharged by the heat pump will be re-circulated DO NOT put the unit next to bushes. This can block the air inlet. Such locations deny a continuous source of fresh air, which reduces the efficiency of the heat pump and can prevent adequate heat delivery. The picture below shows the minimum required distances from each side of the heat pump. 5
6 Distance Install the heat pump as close to the swimming pool as possible to minimize the loss of heat through the piping. Put it on a solid base and place some rubber blocks under the heat pump to eliminate vibrations. Normally, the heat pump is installed within a 7,5 meter radius of the pool. Heat loss is minimal up to distances of 30 meters. The heat loss per 30 meters is estimated at 0.6kw/hour for every 5 C difference between the pool water and surrounding of the pipe. This increases the lifespan around 3-5%. Installation of the valve The placement of the chlorinator, water balance equipment, and the placement of injectors of chemicals, are very important aspects of the installation. All addition of chemicals have to be done downstream from the heat pump. Failure to protect the heat pump unit from chemical damage is not covered by your warranty. A check-valve must be installed between the heat pump and the chemical feeder to prevent back-siphoning of chemically saturated water into the heat pump where it will damage the components. 6
7 Installation of the pool system Installation of the bypass With the bypass set correctly, your heat pump will deliver its best performance. The bypass has to be built as shown below: Setting the valves of the by-pass: Install the bypass with all 3 valves entirely open Slightly close valve 1 Close valve 3 about halfway to adjust the refrigerant pressure 7
8 Electrical wiring Verify the local power supply and the operating voltage of the heat pump. It is recommended to use a separate circuit breaker (slow type D curve) for the heat pump together with the proper wiring characteristics. The current to the heat pump should only be applied when the filter pump is running. For example, a relay controlled by the filter pump could be used to activate the current to the heat pump. Connect the electrical supply to the junction box inside the heat pump. All heat pumps require a single-phase connection. Earthing the heat pump is required to protect you against electrical shocks caused by an eventual short circuit inside the heat pump. The heat pump is not equipped with a flow switch or any other kind of water flow detection. Therefore, the heat pump has to be wired electrically together with the filter pump to ensure water flow while the heat pump is running. Please consult the Appendix for more information Start-up procedure Start-up Procedure - after the installation is completed, you should follow these steps: 1. Turn on your filter pump. Check for water leaks and verify the flow to and from the pool. 2. Turn on the electrical power supply to the heat pump and turn the heat pump ON with the switch. The heat pump will start after the time delay period has lapsed. 3. After running a few minutes, check whether the air leaving the heat pump is now cooler. 4. Allow the unit and pool pump to run 24 hours per day until desired pool water temperature is reached. When the set temperature is reached, the unit just shuts off. The unit will now automatically restart (as long as your pool pump is running) when the pool temperature drops more than 1 degree Celsius below set temperature. Several days are needed to bring the temperature of your swimming pool water to its required value. Water flow switch - the unit is equipped with a flow switch that switches on when enough water has flowed through the unit and vice versa. Time delay - the unit is equipped with a 3-minute built-in delay to protect the control circuit components and to eliminate restart cycling and contactor chatter. This time delay will automatically restart the unit approximately 3 minutes after each circuit interruption. Even a brief power interruption will activate this delay and prevent the unit from starting until the 3-minute countdown is completed. Condensation Since the Heat pump cools down the air about 8-12 C, this causes condense on the fins of the evaporator. If the relative humidity is very high, this could be as much as several liters an hour. Sometimes this condensation water is misjudged as pool water and considered to be a leakage. Guidelines Water chemistry Special care should be taken to keep the chemical balance of your swimming pool within limits: ph 7,0 7,4 Free chlorine 0,5 1,2 mg/l TAC mg/l (10 F 30 F) Salt max 8 g/l 8
9 Failure to keep the swimming pool water between above limits will void the warranty When the concentration of one or more products mentioned above becomes too high, irrevocable damage to your heat pump may occur. Make sure that you always install water treatment equipment after the heat pump. When an automatic chemical feeder is installed, it must be installed downstream of the heat pump. A check-valve must be installed between the heat pump and the chemical feeder to prevent back-siphoning of chemically saturated water into the heat pump where it will damage the components. Winter-ready Failure to winterize the heat pump could cause damage to the heat pump and will void warranty. In areas where freezing temperatures occur, you should protect your pump, filter and heat pump. Perform the following steps to completely drain the heat pump: 1. Turn off the electrical power to the heat pump at the main breaker panel. 2. Shut off the water supply to the heat pump: close valves 2 and 3 on the by-pass completely. 3. Disconnect the water inlet and outlet and let the water drain from the heat pump. 4. Connect the inlet and outlet again to prevent dirt from entering the connections. Spring start-up If your heat pump has been made winter-ready, perform the following steps whilst starting the heat pump again in spring: 1. Inspect the system for any debris or structural problems. 2. Connect the water inlet and outlet unions firmly. 3. Turn on the filter pump to supply water to the heat pump. Adjust the by-pass to allow water flow through the heat pump. 4. Turn on the electrical power to the heat pump at the main panel. Owner inspection The HARMO PAC heat pumps are designed and constructed to provide long performance life when installed and operated properly under normal conditions. Periodic inspections are important to keep your heat pump running safely and efficiently through the years. The following basic guidelines are suggested for your inspection: 1. Make sure the front of the unit is accessible for future service. 2. Keep the surrounding areas of the heat pump clear of all debris. 3. Keep all plants and bushes trimmed and away from the heat pump. 4. Keep lawn sprinkler heads from spraying on the heat pump to prevent corrosion and damage. Use a deflector if needed. 5. If the heat pump is installed under a very sharp roof pitch or under a roof without a gutter, a gutter or diverter should be fitted to prevent excessive water from pouring down onto the heat pump. 6. Do not use the heat pump if any part has been exposed to an excessive amount of water. Immediately call a qualified professional technician to inspect the heat pump and replace any part of the control system, which has been submerged. 9
10 The heat pump will produce condensation (water) operating. The heat pump base is designed to allow the condensation to exit through the bottom drain port. The condensation will increase as the outdoor air humidity level increases. Check the following at regular intervals to ensure proper condensate drainage: 1. Visually inspect and clear the bottom drain port of any debris that could clog the port. 2. Keep the air intake area and discharge area clear of debris so the airflow through the heat pump is not restricted. The cooler discharge air should not accumulate and be drawn into the side air intake coils. During normal operation, the heat pump produces ten to twenty liters of condensation per hour. If condensation drainage is above this range during operation or if water continues to drain from the base when the heat pump is not in operation for more than an hour, a leak in the internal plumbing may have occurred. Call a qualified heat pump technician to investigate the problem. A quick way to verify that the water running through the drain is condensation water is to shut off the unit and keep the pool pump running. If the water stops running out of the base pan, it is condensation water. Display settings 1.Under running status, press 2. Press " M"to choose the mode to adjust the temperature Press "M again for cooling Press "M again for heating 3. Standby status: Press "M" 5 seconds, get a sound B,LCD display will show 0" 27.Press SET to enter cooling temp. setting, press to alter cooling temp. Press "M again" "1 27" Press SET to enter heating temp. setting, press to alter heating temp. Press "M again" " "2 40" Press SET to enter defrosting time setting, press to alter defrosting time. Press "M" again "3" "-7" Press SET to enter defrosting temp. setting, press to alter defrosting temp. Press "M" again "4" "13 " Press SET to enter exit defrosting temp. setting, press to alter exit defrosting temp. Press "M" again "5" "8 " Press SET to enter exit defrosting time setting, press to alter exit defrosting time. Press "M" again "6" "1 " Press SET to enter system quantity setting, press to alter system quantity. Press "M" again "7" "1 " Press SET to enter Automatic setting, press to alter. Press SET again to confirm. 10
11 Press "M" again "8" "1 " Press SET to enter Mode setting, press to alter. Press SET again to confirm. Press "M" again "9" "0 " Press SET to enter water pump setting, press to alter. Press SET again to confirm. Press "M" again "A" "40 " Press SET to enter return water temp. setting, press to alter. Press "M" again "b" "5 " Press SET to enter Overheat protection(heating mode) setting, press to alter. Press "M" again "C" "35 " Press SET to enter Electronic expansion valve setting, press to alter. Press "M" again "D" "5 " Press SET to enter Overheat protection(cooling mode) setting, press to alter. Press "M" again "E" "40 " Press SET to enter Max. temp. setting, press to alter. Press SET again to confirm. Press "M" again "F" "2 " Press SET to enter Split temp. setting, press to alter. Press SET again to confirm. Press "M" again "G" "-10 " Press SET to enter Ambient temp. protection setting, press to alter. Clock settings Under running or standby status. Press SET for 5 seconds, get a sound B, press SET again to alter minute. to alter hour, press Timer settings Under running or standby status, Press for 5 seconds, get a sound B, press to alter hour of timer ON, Press again to alter minute of timer ON. Press again to alter timer OFF. 11
12 Functions of the display o Under standby status, press M button 5s to enter Operation Parameter setting interface;" " o Press"M"again to start setting (parameter from 00-D,see the Operation Parameter Table); o Under parameter setting, press or to set data; o Please note no motion on the display for 10s,the LCD will display water-in/water out temp.(under running)or ambient temp.(under standby status) o Under running status, you can press M" 5s to check current parameter, but you cannot change the data of the parameter! o Remarks: Standby status means the unit is connected with electricity but not running. 12
13 13
14 Current status Ambient temp. C Under running status, press M 5 seconds to check the status of the unit. You can check waterin/water out temp, condenser temp and ambient temp, please note no motion on the display for 10s, the LCD will display water-in/water out temp/ (under running) or1ambient temp. (unit stops). Maintenance o o o o o o Check the water supply to the unit often. Low water flow and air entering into the system should be avoided, as this will diminish the units performance and reliability. You should clean the pool filter regularly to avoid damage to the heat pump as a result of the dirty or clogged filter. The area around the heat pump should be dry, clean and well ventilated. Clean the heat exchanger regularly to maintain a good heat exchange and to save energy. Only a certified technician should service the operating pressure of the refrigerant system. Check the power supply and cable connection often. Should the unit begin to operate abnormally, switch it off and contact a qualified technician. In winter, please discharge all water from the water pump and other systems to prevent damage by freezing. Discharge the water at the bottom of the heat pump if the unit will not work for an extended period of time. You should check the unit thoroughly and fill the system with water fully before using it for the first time after a prolonged period of no usage. 14
15 Appendix 15
Instruction manual Harmo PAC ZVWX1017/1022/1032/1041/1055/1056/1061
Instruction manual Harmo PAC ZVWX1017/1022/1032/1041/1055/1056/1061 Imported by: Zwembad BVBA Industrieweg 9 3190 Boortmeerbeek België www.harmopool.eu 0 Table of content Introduction... 2 Safety instructions...
More informationSWIMMING POOL HEAT PUMP UNIT ECO - series. Installation & Instruction manual
SWIMMING POOL HEAT PUMP UNIT ECO - series Installation & Instruction manual Rev. 1.00 28.11.2007 Contents SWIMMING POOL HEAT PUMP UNIT 1 CONTENTS 2 1. PREFACE 3 2. SPECIFICATIONS 4 2.1 Performance data
More informationSWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual Duratech - series
SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual Duratech - series Rev. 3.32 26.01.2007 CONTENTS 1. Preface 3 2. Specifications 4 2.1 Performance Data of swimming Pool Heat Pump Unit 4 2.2
More informationHarmo Powerpack Horizontal Units Installation & instruction manual
Imported by: Zwembad BVBA Industrieweg 9 3190 Boortmeerbeek België www.harmopool.eu Harmo Powerpack Horizontal Units Installation & instruction manual Table of content Introduction... 3 Characteristics...
More informationSWIMMING POOL HEAT PUMP UNIT
SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual A pplicable M odel: YA P S 1-4 5HL YA P S 1-9 0HL YA P S 1-1 40HL YA P S 1-6 5HL YA P S 1-1 20HL 1. Preface * In order to provide our customers
More informationOWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA
OWNER S MANUAL Vintage Classic HEAT COOL models Proudly Made in the USA support@aquacomfort.com www.aquacomfort.com/service-and-support 888-475-7443 Manufacturing High Quality, High Efficiency Heat Pump
More informationSWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual
SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual OASIS C10 HEAT PUMP Head Office 62 Parkhurst Drive Knoxfield VIC 3180 T: 03 9887 2131 New South Wales Unit 1, 20-22 Foundry Road Seven Hills
More informationOWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA
OWNER S MANUAL Models: AC110, AC125, AC150 made from 2003 through 2010 Proudly Made in the USA support@aquacomfort.com www.aquacomfort.com/service-and-support/ (888) 475-7443 Manufacturing High Quality,
More informationMiNI SWIMMING POOL HEAT PUMP UNIT. Installation & Instruction Manual
MiNI SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual 5.Maintenance and inspection 5.1 Maintenance To check the water supply device and the releaser often. You should avoid the condition
More informationSWIMMING POOL HEAT PUMP UNIT. Installation & Instruction Manual
SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual CONTENTS. Preface. Specifications. Performance Data of Swimming Pool Heat Pump Unit. Dimensions for Swimming Pool Heat Pump Unit 3. Installation
More informationOWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.
OWNER S MANUAL Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750 Proudly Made in the USA support@aquacomfort.com 888-475-7443 Manufacturing High Quality, High Efficiency Heat
More informationSWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL
SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL MODEL AT105 AT115 AT130 with Titanium Heat Exchanger 2213 Andrea Lane Ft. Myers FL 33912 888-297-3826 941-482-0606 www.aquathermheatpumps.com DIGITAL
More informationWarning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)
1 2 Warning: - Do not place your hand or any other objects into the air outlet and fan. It could damage the heat pump and cause injuries; - In case of any abnormality with the heat pump, cut off the power
More informationINSTALLATION AND USER MANUAL
INSTALLATION AND USER MANUAL t Thank you for choosing Aqua inverter heat pump. This manual provides you necessary information for optimal use and maintenance, please read it carefully and keep it for subsequent
More informationINSTALLATION AND USER MANUAL
INSTALLATION AND USER MANUAL Thank you for choosing inverter heat pump. This manual provides you necessary information for optimal use and maintenance, please read it carefully and keep it for subsequent
More informationThis manual should be maintained in legible condition and kept adjacent to the heat pump or in a safe place for future use.
Perfectemp Swimming Pool Heat Pump CE OWNER S MANUAL Models PT4, PT6, and PT8 R C LISTE D 9900276 US This manual should be maintained in legible condition and kept adjacent to the heat pump or in a safe
More informationSWIMMING POOL HEAT PUMP UNIT. Installation & Instruction Manual
SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual CONTENTS. Preface. Specifications. Performance Data of Swimming Pool Heat Pump Unit. Dimensions for Swimming Pool Heat Pump Unit. Installation
More informationTHERMOTEC INVERTER SWIMMING POOL HEAT PUMP
THERMOTEC INVERTER SWIMMING POOL HEAT PUMP Installation & Instruction Manual for Horizontal Models 9kw, 12kw, 17kw, 20kw, 24kw Version 4.0 Table of contents 1. Preface 3 2. Specifications 2.1 Performance
More informationOwner s Manual for Swimming Pool Heat Pump
Owner s Manual for Swimming Pool Heat Pump FC Series nirvanahp.com CONTENTS How it works 1 Installation 2 3 Settings 4 5 6 7 Start-up 8 Winterizing 9 Maintenance 10 Troubleshooting 11 12 13 Warranty 14
More informationSWIMMING POOL HEAT PUMP UNIT POMPA DI CALORE PER PISCINA
SWIMMING POOL HEAT PUMP UNIT POMPA DI CALORE PER PISCINA SWIMMING POOL HEAT PUMP UNIT CONTENTS 1. Preface 1 2. Spec 2.1 Performance Data of Swimming Pool Heat Pump Unit 2 2.2 Dimensions for Swimming Pool
More informationSWIMMING POOL HEAT PUMP UNIT POMPA DI CALORE PER PISCINA. Installation & Instruction Manual - p. 1 Manuale di Installazione e d'uso p.
SWIMMING POOL HEAT PUMP UNIT POMPA DI CALORE PER PISCINA Installation & Instruction Manual - p. 1 Manuale di Installazione e d'uso p. 21 SWIMMING POOL HEAT PUMP UNIT CONTENTS 1. Preface 1 2. Spec 2.1 Performance
More informationINSTALLATION AND USER MANUAL
Swimming Pool Heat Pump Swimming Pool Heat Pump INSTALLATION AND USER MANUAL Thank you for choosing our product and trusting our company. This manual is to provide you with necessary information for optimal
More informationOwner's Manual TABLE OF CONTENTS
40MAQ High Wall Ductless System Sizes 09 to 36 Owner's Manual TABLE OF CONTENTS PAGE A NOTE ABOUT SAFETY... 2 GENERAL... 2 PART NAMES... 3 FUNCTION BUTTONS... 4 DISPLAY PANELS... 5 REMOTE CONTROL... 6
More informationMODEL 598A TWO-SPEED PLUS CENTRAL AIR CONDITIONER
USER S INFORMATION MANUAL MODEL 598A TWO-SPEED PLUS CENTRAL AIR CONDITIONER NOTE TO INSTALLER: This manual must be left with the equipment user. WELCOME TO EFFICIENT HOME COOLING COMFORT Congratulations
More informationINSTALLATION AND USER MANUAL
INSTALLATION AND USER MANUAL Thank you for choosing our product and trusting our company. This manual is to provide you with necessary information for optimal use and maintenance, please read carefully
More informationUSER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.
USER MANUAL Portable Air Conditioner and Heater With Heat Pump Technology PAC12 PAC15 PAC18 Please read this manual carefully prior to operating the product. TABLE OF CONTENTS INTRODUCTION... 3 IMPORTANT
More informationInverter Swimming Pool Heat Pump
P Inverter Swimming Pool Heat Pump Content I. Application... 2 II. Features... 2 III. Technical Parameter... 3 IV. Dimension... 4 V. Installation instruction... 5 VI. Operation instruction... 9 VII. Testing...
More informationOwner s Manual PRINTED IN CANADA 05/2009
Owner s Manual PRINTED IN CANADA 05/2009 Table of contents Introduction 2 General Safety Instructions 4 Installation Instructions Location 6 Water piping 7 Electrical 7 Bonding 8 Bonding and plumbing
More informationOWNER S Manual PRINTED IN CANADA 10/2009
OWNER S Manual PRINTED IN CANADA 10/2009 Table of contents Introduction 2 General Safety Instructions 4 Installation Instructions Location 6 Water piping 7 Electrical 7 Bonding 8 Bonding and plumbing
More information11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International
11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions Model No. PE4-11R-03 2006 Soleus Air International Thank you for choosing a Soleus Air Portable Air Conditioner.
More informationSWIMMING POOL & SPA HEAT PUMPS INSTALLATION MANUAL
PROLOGIC CONTROL POWER PROLOGIC CONTROL POWER POOL SPA HEATING POOL SPA HEATING NO WATER FLOW NO WATER FLOW FAULT FAULT POWER POOL SPA HEATING NO WATER FLOW FAULT PROLOGIC CONTROL POWER POOL SPA HEATING
More informationTHROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H
THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER Instruction Manual Model AMB-12H PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USING THIS UNIT. Table of Contents 1. SAFETY WARNINGS 2 2. CONSTRUCTION...
More informationModel No.: PS08-01 PS10-01 Ref: KY80 KY100
8,000/10,000/12,000 BTU Portable Air Conditioner Operating Instructions Model No.: PS08-01 PS10-01 Ref: KY80 KY100 Model No.: PS12-03 Ref: KY120 3119233 V160310 Thank you for choosing a Soleus Air Portable
More informationOwner's Manual TABLE OF CONTENTS
40MB*D Ducted Style Ductless System Sizes 09 to 48 Owner's Manual TABLE OF CONTENTS PAGE A NOTE ABOUT SAFETY... 2 GENERAL... 2 PARTS LIST... 3 DISPLAY PANELS... 4 FUNCTION BUTTONS... 5 REMOTE CONTROL...
More informationOperating Instructions
Operating Instructions Air Conditioner Model No. Indoor Unit CS-E12QD3RW CS-E18QD3RW Single Split Outdoor Unit CU-E12QD3R CU-E18QD3R Multi Split Outdoor Unit CU-4E23QBR CU-4E27QBR CU-5E34QBR Operating
More informationPortable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology
Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology OWNER'S MANUAL Model # KY-34 3046364 Please read owner s manual carefully before operating unit. TABLE OF CONTENTS INTRODUCTION...3
More informationOWNER and INSTALLATION MANUAL
Raypak RHP Series Swimming Pool and Spa Heat Pump OWNER and INSTALLATION MANUAL Model RHP 33 R C LI ST ED 9900276 US This manual should be maintained in legible condition and kept adjacent to the heat
More informationSwedish design and manufacture since 1967
Swedish design and manufacture since 167 PVP MA20-14 rev.2 Manual User manual Copyright 2017 Pahlén AB, Box 728, SE-14 27 Upplands Väsby, Sweden Tel. +46 8 54 110 50, Fax +46 8 50 868 80, e-mail: info@pahlen.se,
More informationOWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)
OWNER S MANUAL HIGH WALL INVERTER (English) (BSHVD1S SERIES) IMPORTANT As with any product that has moving parts or is subject to wear and tear, it is VERY IMPORTANT that you maintain your air conditioner
More informationT-Series Air Conditioner T15 Model
INSTRUCTION MANUAL T-Series Air Conditioner T15 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200
More informationPortable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU
Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU OPERATING INSTRUCTIONS PCR-06-01 PCR-08-01 PCR-10-01 3058080 V170223 PURCHASE INFORMATION Thank you for choosing a Chigo Portable Air Conditioner.
More information5) Do not start or stop the unit by inserting or pulling out the power plug.
3058080 V170306 PURCHASE INFORMATION Thank you for choosing a Soleus Air Portable Air Conditioner. This Owner s Manual will provide you with valuable information necessary for the proper care and maintenance
More informationT-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N
T-SERIES Air Conditioner T29 Model INSTRUCTION MANUAL Rev. I P/N 89104464 TABLE OF CONTENTS Warranty and Return Policy...2 IMPORTANT NOTICE...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE
More informationINSTALLATION MANUAL. G&F Manufacturing 7902 Interstate Court North Fort Myers, Florida
INSTALLATION MANUAL G&F Manufacturing 7902 Interstate Court North Fort Myers, Florida Heat Pump Services 990 NW 53rd Street Fort Lauderdale, Florida 33309 G&F Manufacturing 7902 Interstate Court North
More informationSwimming Pool Heat Pump
Swimming Pool Heat Pump Operation and Installation Manual MODEL FH-020 CONTENTS INTRODUCTION Index............ 2 The unit...... 2 SAFETY INSTRUCTIONS... 4 Electrical Installation Warning.. 4 Location Warning
More informationTECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A
TECHNICAL & SERVICE MANUAL SA 183A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. SA-183A 1 851 006 96 Destination Australia SA 183A REFERENCE NO. SM700514 IMPORTANT! Please Read Before
More informationT-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N
T-SERIES Air Conditioner T43 Model INSTRUCTION MANUAL Rev. I P/N 10-1008-145 TABLE OF CONTENTS Warranty and Return Policy...2 IMPORTANT NOTICE...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING
More informationNOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.
RADS-51J RADS-61J Owner s Manual Room Air Conditioner with R-410A Heat Controller, Inc. 15 16 Contact an authorized service technician for repair or maintenance of this unit. Contact an authorized installer
More informationG&F Manufacturing Swimming Pool Heat Pump Install & Operations Manual
G&F Manufacturing Swimming Pool Heat Pump Install & Operations Manual 5005001B Version 5.2 TABLE OF CONTENTS Introduction 3 Water Chemistry Maintenance 5 Installation o Location of Heater 6 o Tie Downs
More informationOWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump
R-10A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFF(A/H)H, DFC(A/H) Please read the operating instructions and safety precautions carefully and thoroughly before installing and
More informationOWNER S MANUAL HIGH WALL INVERTER. (English) (MSHVD1S SERIES)
OWNER S MANUAL HIGH WALL INVERTER (English) (MSHVD1S SERIES) IMPORTANT As with any product that has moving parts or is subject to wear and tear, it is VERY IMPORTANT that you maintain your air conditioner
More informationHydro-S Heat pump 230V black type 12horizontal. Swimming Pool HeatPump UserandServicemanual
7018517 Hydro-S Heat pump 230V black type 3 horizontal 7018518 Hydro-S Heat pump 230V black type 5 horizontal 7018519 Hydro-S Heat pump 230V black type 8 horizontal 7018520 Hydro-S Heat pump 230V black
More informationOwner s Manual TABLE OF CONTENTS
40MBDQ Ducted Style Ductless System Sizes 18 to 48 Owner s Manual TABLE OF CONTENTS PAGE A NOTE ABOUT SAFETY... 2 GENERAL... 2 PARTS LIST... 3 DISPLAY PANELS... 4 FUNCTION BUTTONS... 5 REMOTE CONTROL...
More informationOWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump
R 410A Ductless Split System Air Conditioner and Heat Pump Models DLC4(A/H) Outdoor Unit, DLF4(A/H) Indoor Unit Sizes 9K, 12K, 18K, 24K, 30K and 36K Please read the operating instructions and safety precautions
More informationBulletin (Jan 2011) And User s Guide
Bulletin 30 32 (Jan 2011) Unichiller Installation And User s Guide Customer Service If you have questions about Installation, operation and Maintenance of the Unichiller or would like to order replacement
More informationOWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36
OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36 TABLE OF CONTENTS PAGE SAFETY PRECAUTIONS... 2 GENERAL... 2 INDOOR UNIT PART NAMES... 3 REMOTE CONTROL PART NAMES...
More informationContents. Specifications. Description SV HP 55 SV HP 90. Specifications Warnings Introduction Overview... 4
Contents Specifications Specifications... 1 Warnings... 2 Introduction... 3 Overview... 4 Installation Instructions... 5 Cable Connections... 6 Plumbing Diagram... 7 Electrical Wiring Diagram... 8 SV System
More informationCENTRAL AIR CONDITIONER
USER S INFORMATION MANUAL CENTRAL AIR CONDITIONER NOTE TO INSTALLER: This manual must be left with the equipment user. WELCOME TO EFFICIENT HOME COOLING COMFORT Congratulations on your excellent choice
More informationSWIMMING POOL HEAT PUMP UNITS. Installation & Instruction Manual EU - series
SWIMMING POOL HEAT PUMP UNITS Installation & Instruction Manual EU - series Rev. 2.00 20.12.2010 Contents SWIMMING POOL HEAT PUMP UNITS 1 Contents 2 1. Preface 3 2. Specifications 4 2.1 Technical data
More informationModel No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions
Model No. GB-PAC-08E4 8,000 BTU Portable Air Conditioner Operating Instructions Thank you for choosing a Soleus Air Powered by Gree Portable Air Conditioner. This owner s manual will provide you with valuable
More informationT-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N
T-SERIES Air Conditioner T50 Model INSTRUCTION MANUAL Rev. F P/N 10-1008-203 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3
More informationSWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 5.6kW 9.5kW and 12.5kW models only. The heat pump unit is sold with a 2 year warranty on all components. Please contact your supplying dealer
More informationSWIMMING POOL HEAT PUMP UNIT. Installation & Instruction Manual
SWIMMG POOL HEAT PUMP UNIT Installation & Instruction Manual ONTENTS. Preface. Specifications. Performance Data of Swimming Pool Heat Pump Unit. Dimensions for Swimming Pool Heat Pump Unit.3 How to disassemble
More informationCAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS
Owner s Manual CR2500ACH CR5000ACH Portable Heating and Air Conditioning Unit Version 02 Table of Contents 1. SAFETY INSTRUCTIONS... 1-1 CAREFULLY READ THESE INSTRUCTIONS BEFORE USING... 1-1 SAFETY PRECAUTIONS...
More information2 shp 13 lc 1 36 t - 1 a
HEAT PUMPs 2SHP3 PRODUCT SPECIFICATIONS Dry Charge Split System - 60 HZ Bulletin No. 20645 July 203 Supersedes June 202 3 to 5 Tons MODEL NUMBER IDENTIFICATION 2 shp 3 lc 36 t - a Refrigerant Type 2 =
More information40KMC KMQ
40KMC------301 40KMQ------301 OWNER S MANUAL Split system Global cassette indoor unit IR Remote Control Room Controller Zone Manager The unit can be used with infrared Remote Control, with the Carrier
More informationUSER MANUAL SILENT16 PORTABLE AIR CONDITIONER
USER MANUAL SILENT16 PORTABLE AIR CONDITIONER Thank you for choosing electriq Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference. Visit our
More informationCR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions
OWNER S MANUAL Operating and Servicing Instructions CR13000-PAC PORTABLE AIR CONDITIONER with HEAT PUMP Portable Air Conditioner Questions or concerns? For assistance, please call Customer Service ClimateRight
More informationDEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST
COMFORT...BUILT TO LAST 11 PINT DEHUMIDIFIER USER MANUAL FOR MODEL: 3PAD11 Before using your dehumidifier, please read this manual carefully and keep it for future reference, along with your receipt. CONTENTS
More informationSWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP INSTALLATION AND OPERATION MANUAL IMPORTANT It is important to register your product with us on our web site. This will help us find your warranty when you place a service call.
More informationT-Series Air Conditioner T53 Model
INSTRUCTION MANUAL T-Series Air Conditioner T53 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200
More informationT-Series Air Conditioner T20 Model
INSTRUCTION MANUAL T-Series Air Conditioner T20 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200
More informationGENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N
GENESIS Air Conditioners All Models INSTRUCTION MANUAL Rev. K P/N 89104462 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3
More informationPROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N
PROAIR Air Conditioner CR23 Model INSTRUCTION MANUAL Rev. D P/N 89112522 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3
More informationTECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513
TECHNICAL & SERVICE MANUAL SA 123A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-123A 1 851 006 95 Australia SA 123A REFERENCE NO. SM700513 IMPORTANT! Please Read Before
More informationInstallation, Operation, and Maintenance Information
Installation, Operation, and Maintenance Information Low Velocity Unit Coolers Bulletin No. IOM 110.3 Table of Contents Inspection... 2 Installation... 2 4 General... 2 Location... 2 Drain Line... 3 Refrigerant
More informationEBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL CD425 (1018110) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News, VA 23606 Tel: 757 873 6800 Fax: 757 873 3632 Website: www.ebacusa.com
More informationSWIMMING POOL HEAT PUMP UNIT
SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual Rev. WF PHP 09.06.2017 1.27.1000105 Advice to customers 1. Please read this manual carefully before installing the product, otherwise you
More informationWINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL
MODEL RA-0LDF RA-3LDF WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL AIR DEFLECTORS VERTICAL DEFLECTORS Vertical de ectors at both sides of outlets can be set to either auto-swing or
More informationPool & Spa The Duratech Heat Pumps
Pool & Spa The Duratech Heat Pumps The ideal solution for heating your swimming pool and spa. Bosta... Creating Connections Bosta, pipeline Components for Pools Spas and much much more... Introducing the
More informationWMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS
WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS **WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER** Altering the product or replacing parts with non authorized factory parts voids all warranty
More informationULTRA LOW TEMPERATURE FREEZER. User Manual
ULTRA LOW TEMPERATURE FREEZER User Manual Note:Kaltis reserves the right to modify any parts of this manual without prior notice. 1. No part of this manual may be reproduced in any form, or translated
More informationUltraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL
Ultraviolet Systems Inc. UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL TABLE OF CONTENTS SECTION 1 General Information 1A. Description...1 1B. Specifications...1 SECTION 2 Installation 2A. Pool Preparation...
More informationPool & Spa The Duratech Heat Pumps
Pool & Spa The Duratech Heat Pumps The ideal solution for heating your swimming pool and spa. Bosta... Creating Connections Bosta, pipeline Components for Pools Spas and much much more... Introducing the
More informationCAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS
Owner s Manual CR2500ACH CR5000ACH Portable Heating and Air Conditioning Unit Version 01 Table of Contents 1. SAFETY INSTRUCTIONS... 1-1 CAREFULLY READ THESE INSTRUCTIONS BEFORE USING... 1-1 SAFETY PRECAUTIONS...
More informationPORTABLE AIR-CONDITIONER MODEL: EPAC-A4010D(WH) Owner s Manual Please read this manual carefully before operating your set.
PORTABLE AIR-CONDITIONER MODEL: EPAC-A4010D(WH) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference. Record model number and serial number of the
More informationOwner s Manual & Installation Guide. Model 525S Model 525TI Model 650TI Model 650SC Model 700TI
Owner s Manual & Installation Guide Model 525S Model 525TI Model 650TI Model 650SC Model 700TI KOPEC Enterprises, Inc., located in Pompano Beach, Florida, designs and manufactures the industry's most cutting-edge
More informationEBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 700 Thimble Shoals Boulevard Newport News VA 23606-2575 Telephone (757) 873-6800 Fax (757) 873-3632 Website: www.ebacusa.com INTRODUCTION
More informationPortable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217
Portable Air Conditioner with Heat Pump Technology Operating Instructions 3092402 Model No.: HCB-P13HP-D Reference No.: BPD13HP V140217 Thank you for choosing a Soleus Air Portable Air Conditioner with
More informationFORCE SERIES SWIMMING POOL HEAT PUMP INSTALLATION AND OPERATION MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING OR OPERATING THE UNIT
FORCE SERIES SWIMMING POOL HEAT PUMP INSTALLATION AND OPERATION MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING OR OPERATING THE UNIT 1 CHAPTER 1: Installation Chapter 1 deals with installation
More informationEBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL
EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News VA 23606 Telephone (757) 873-6800 FAX (757) 873-3632 Website: www.ebacusa.com INTRODUCTION
More informationSPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N
SPECTRACOOL Air Conditioner N21 Model INSTRUCTION MANUAL Rev. G P/N 89115088 TABLE OF CONTENTS WARRANTY AND RETURN POLICY...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3
More informationUSER MANUAL SILENT12 PORTABLE AIR CONDITIONER
USER MANUAL SILENT12 PORTABLE AIR CONDITIONER Thank you for choosing electriq Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference. Visit our
More informationUser Guide ems25plus. Page 1. Normal operation. Product interface
Page 1 Product interface rmal operation During normal operation, EMS controllers display the information below. Assuming the product temperature is correct when the outlet is open, this means that the
More informationSwimming Pool Heat Pump
Swimming Pool Heat Pump - Operation and Installation Manual - Model:LCSPI-95BP,LCSPI-135BP,LCSPI-180BP, LCSPI-220BP, LCSPI-280BP TABLE OF CONTENT INTRODUCTION...... 2 This manual... 2 The Heat Pump...
More informationULTRATEMP TM HX HIGH PERFORMANCE HEAT PUMP
ULTRATEMP TM HX HIGH PERFORMANCE HEAT PUMP Should the installer or owner be unfamiliar with the correct installation or operation of this type of equipment, you should contact the distributor/manufacturer
More informationOwner s Manual Window Air Conditioner
Owner s Manual Window Air Conditioner G17-5MCVWAC1 G16-5MCVWAC Write the model and serial numbers below for your records: Model # Serial # Date Purchased Please read the entire manual carefully to ensure
More informationFOR THE RECORD. You should record the model and serial numbers, which can be found on the back of the unit, for future reference.
FOR THE RECORD You should record the model and serial numbers, which can be found on the back of the unit, for future reference. Warranty: 18 mo. on unit and 1 year on check valve assembly Model: The Ozone
More informationSurna 25-Ton Chiller Operating & Maintenance Manual
www.surna.com 303.993.5271 Surna 25-Ton Chiller Operating & Maintenance Manual Models: 300F3-3. 300F4-3, 300FW-3 Revised: July 2015 Table of Contents Warranty Information 4 Limited Warranty 4 Limitation
More informationCOMPACT PORTABLE AIR CONDITIONER USER MANUAL
COMPACT PORTABLE AIR CONDITIONER USER MANUAL Thank you for choosing ElectriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference. Visit our page
More information