Instruction manual Harmo PAC ZVWX1017/1022/1032/1041/1055/1056/1061

Size: px
Start display at page:

Download "Instruction manual Harmo PAC ZVWX1017/1022/1032/1041/1055/1056/1061"

Transcription

1 Instruction manual Harmo PAC ZVWX1017/1022/1032/1041/1055/1056/1061 Imported by: Zwembad BVBA Industrieweg Boortmeerbeek België 0

2 Table of content Introduction... 2 Safety instructions... 3 Specifications... 4 Installation... 5 Installation items... 5 Location... 5 Installation of the valve... 6 Installation of the pool system... 7 Installation of the bypass... 7 Electrical wiring... 8 Start-up procedure... 8 Condensing... 8 Guidelines... 9 Water chemistry... 9 Winter-ready... 9 Spring start-up Owner inspection Display Controller Operation The buttons of LED wire controller Activating the heat pump Setting the heating/cooling mode Setting the real time Water temperature setting Automatic start/stop the heat pump Running data setting Current status Q&A Error code Other malfunctions Maintenance

3 Introduction Read the manual carefully before you open or maintain the unit. The manufacturer of this product will not be held responsible for injuries or damage to the unit, as a result of improper installation, debugging or unnecessary maintenance. It is essential that the instructions of this manual are adhered at all times. Qualified personnel must install the unit. A qualified installer, center, personnel or an authorized dealer, can only repair the unit. Maintenance and operation must be carried out according to the recommended time and frequency, as stated in this manual. Use genuine standard spare parts only. Failure to comply with these recommendations will void warranty. Characteristics Durable: The heating exchanger is made of PVC & Titanium tube, which can withstand prolonged exposure to swimming pool water. Easy operation: The desired temperature can be easily. Instructions can be found in this manual. Quiet operation: Through the intelligent LCD controller, the desired water temperature can be set Low cost: The operational cost is very low due to its high performance. 2

4 Safety instructions Place the heat pump at a safe distance. Never place the pump within a radius of 350cm from the pool. Your heat pump may be fitted with a RCD safety plug. Put the RDC plug directly and solely into a grounded wall outlet. Never use an extension cord or similar. Check the voltage on the plug to the power at the socket. Only use a grounded outlet. Always check that the safety plug is working properly to ensure safety. Never remove the safety plug. Place the pump and plug in a dry location. The failure to comply with these instructions could result in serious injuries. Safety test Splash-proof 1. See the wiring diagram in the manual. 2. Plug into the socket. 3. Press the RESET button. The indicator "ON (on)" is highlighted. 4. Press the "TEST" button. The indicator "ON (on) goes out. 5. Press the RESET button for use of the device. Do not use if above test fails 3

5 Specifications Product code: ZVWX1017 ZVWX1022 ZVWX1032 ZVWX1041 ZVWX1055 ZVWX1056 ZVWX1061 Product type: MONO MONO MONO Vertical/MONO Vertical/MONO Vertical/TRI Vertical/TRI COP 27 T air 24 T water Minimum outside temperature Heating Capacity (kw) 27 T air Nominal power consumption (A) 5,1 7,3 9,5 13, ,5 12,4 Nominal water flow rate (m³ / h) 3 to 5 5 to 7 6 to 8 8 to to to to 13 Heat exchanger Titanium Titanium Titanium Titanium Titanium Titanium Titanium Airflow (m³/h) kw Connection (mm) Control panel Digital Digital Digital Digital Digital Digital Digital Compressor (number) Ventilators db RPM ventilator Weight Compressor Rotary Rotary Rotary Scroll Scroll Scroll Scroll Volt 230V 230V 230V 230V 230V 380V 380V 4

6 Installation Installation items The factory only provides the heat pump unit. Other necessary items, according to the illustration are to be provided by the user or installer. Attention! Please follow according to the following steps whilst installing the heat pump: The chemicals have to be added downstream of the heat pump. It is recommended to install a bypass when the flow of the pool pump is more than 20% of the rated flow of the heat pump. Install the heat pump on a solid foundation and use the damping rubbers to eliminate vibrations and noise. Keep the unit straight up at all times. When the unit has been tilted, it is required to wait 24 hours before re-starting the heat pump. Location The unit may be installed practically anywhere outdoors. DO NOT put the unit in an enclosed area with a limited air volume where the unit discharge air will be re-circulated. DO NOT put the unit next to shrubs. This may block the air inlet. Such locations deny a continuous source of fresh air, which reduces its efficiency and may prevent adequate heat delivery. The picture below give the minimum required distances from each side of the heat pump: 5

7 Distance Install the heat pump as close to the swimming pool as possible to minimize the loss of heat through the piping. Put it on a solid base and place the rubber blocks under the heat pump to eliminate vibrations. Normally, the heat pump is installed within a 7,5 meter radius of the pool. Heat loss is minimal up to distances of 30 meters. The heat loss per 30 meters is estimated at 0.6kw/hour for every 5 C difference between the pool water and surrounding of the pipe. This increases the operation time around 3-5%. Installation of the valve Attention! Placement of the chlorinator, water balance equipment, and the placement of injectors of chemicals, are very important aspects of the installation. All addition of chemicals have to be done downstream from the heat pump. Failure to protect the heat pump unit from chemical damage is not covered under the warranty. 6

8 Installation of the pool system Installation of the bypass With the bypass set correctly, your heat pump will deliver its best performance. The bypass has to be built as show below: Setting the valves of the by-pass: Set all 3 valves entirely open Slightly close valve 1 Close valve 3 about half way to adjust the refrigerant pressure 7

9 Electrical wiring Attention! Verify the local power supply and the operating voltage of the heat pump. It is recommended to use a separate circuit breaker (slow type D curve) for the heat pump together with the proper wiring characteristics. The current to the heat pump should only be applied when the filter pump is running. For example, a relay controlled by the filter pump could be used to activate the current to the heat pump. Connect the electrical supply to the junction box inside the unit. All heat pumps require single-phase connection. Grounding the heat pump is required to protect you against electrical shocks caused by an eventual short circuit inside the unit. The heat pump is not equipped with a flow switch or any other kind of water flow detection. Therefore, the heat pump has to be wired electrically together with the filter pump to ensure water flow while the heat pump is running. Please consult the Appendix for more information. Start-up procedure Start-up Procedure - after the installation is completed, you should follow these steps: 1. Turn on your filter pump. Check for water leaks and verify the flow to and from the pool. 2. Turn on the electrical power supply to the unit and turn the unit ON with the switch. The unit will start after the time delay period has lapsed. 3. After running a few minutes, check whether the air leaving the side of the unit cooled down. 4. Allow the unit and pool pump to run 24 hours per day until desired pool water temperature is reached. When the set temperature is reached, the unit just shuts off. The unit will now automatically restart (as long as your pool pump is running) when the pool temperature drops more than 1 degree Celsius below set temperature. Several days are needed to bring the temperature of you swimming pool water to its required value. Water flow switch- The unit is equipped with a flow switch that switches on when enough water has flowed through the unit and vice versa. Time Delay - the unit is equipped with a 3-minute built-in delay to protect the control circuit components and to eliminate restart cycling and contactor chatter. This time delay will automatically restart the unit approximately 3 minutes after each circuit interruption. Even a brief power interruption will activate this delay and prevent the unit from starting until the 3-minute countdown is completed. Condensing Since the Heat pump cools down the air about 8-12 C, causing condense on the fins of the evaporator. If the relative humidity is very high, this could be as much as several liters an hour. Sometimes this condensation water is misjudges and considered a leakage. 8

10 Guidelines Water chemistry Special care should be taken to keep the chemical balance of your swimming pool within limits: ph 7,0 7,4 Free chlorine 0,5 1,2 mg/l TAC mg/l (10 F 30 F) Salt max 3 g/l Attention! Failure to keep the swimming pool water between above limits will void the warranty When the concentration of one or more products mentioned above becomes too high, irrevocable damage to your heat pump may occur. Make sure that you always install water treatment equipment after the heat pump. When an automatic chemical feeder is installed in the plumbing, it must be installed downstream of the heat pump. A check-valve must be installed between the heat pump and the chemical feeder to prevent backsiphoning of chemically saturated water into the heat pump where it will damage the components. Winter-ready Attention! Failure to winterize could cause damage to the heat pump and will void warranty In areas where freezing temperatures occur, you should protect your pump, filter and heat pump from the elements. Perform the following steps to completely drain the heat pump: 1. Turn off the electrical power to the heat pump at the main breaker panel. 2. Shut off the water supply to the heat pump: close valves 2 and 3 on the by-pass completely. 3. Disconnect the water inlet and outlet and let the water drain from the heat pump. 9

11 Spring start-up If your heat pump has been made winter-ready, perform the following steps whilst starting the system in the spring: 1. Inspect the system for any debris or structural problems. 2. Connect the water inlet and outlet unions firmly. 3. Turn on the filter pump to supply water to the heat pump. Adjust the by-pass to allow water flow through the heat pump. 4. Turn on the electrical power to the heat pump at the main breaker panel. Owner inspection The ECO heat pumps are designed and constructed to provide long performance life when installed and operated properly under normal conditions. Periodic inspections are important to keep your heat pump running safely and efficiently through the years. The following basic guidelines are suggested for your inspection: 1. Make sure the front of the unit is accessible for future service. 2. Keep the surrounding areas of the heat pump clear of all debris. 3. Keep all plants and shrubs trimmed and away from the heat pump. 4. Keep lawn sprinkler heads from spraying on the heat pump to prevent corrosion and damage. Use a deflector if needed. 5. If the unit is installed under a very sharp roof pitch or under a roof without a gutter, a gutter or diverter should be fitted to prevent excessive water from pouring down onto the unit. 6. Do not use the heat pump if any part has been under water. Immediately call a qualified professional technician to inspect the heat pump and replace any part of the control system, which has been submerged. The heat pump will produce condensation (water) while in operation. The heat pump base is designed to allow the condensation to exit through the bottom drain port. The condensation will increase as the outdoor air humidity level increases. Check the following at regular intervals to ensure proper condensate drainage: 1. Visually inspect and clear the bottom drain port of any debris that could clog the port. 2. Keep the air intake area and discharge area clear of debris so the airflow through the heat pump is not restricted. The cooler discharge air should not accumulate and be drawn into the side air intake coils. During normal operation, the heat pump produces ten to twenty liters of condensate per hour. If condensate drainage is above this range during operation or if water continues to drain from the base when the heat pump is not in operation for more than an hour, a leak in the internal plumbing may have occurred. Call a qualified heat pump technician to investigate the problem. Attention! A quick way to verify that the water running through the drain is condensation water is to shut off the unit and keep the pool pump running. If the water stops running out of the base pan, it is condensation water. 10

12 Display Controller Operation The buttons of LED wire controller When the heat pump is running, the LED display shows the inlet water temperature. When the heat pump is standby, the LED display shows the real time. Activating the heat pump. Press ON to start the heat pump unit, the LED display shows the desired water temperature for 5 seconds, then shows the inlet water temperature. Press OFF to stop the heat pump unit. Setting the heating/cooling mode Press Setting the real time On standby or running mode, press for 10 seconds, then press or to adjust hour/minute. Then press the cannot work. again to store the new data. Whilst setting the time, and 11

13 Water temperature setting On standby or running mode, press temperature. and to adjust the desired water Note : the heat pump can running only if the water circle/filtration system is running. Automatic start/stop the heat pump To set the time to start the unit Press to set the time to start the unit,then press the time (set the time for start 5 minutes after the pump). Press again to store the new data. To set the time to stop the unit Press to set the time to stop running, then press or to adjust the time (set the time for stop 5 minutes before the water pump). Press again to store the new data. Concell the automatic start/stop To concell the automatic starter Press, then press, light off and the automatic start is off. To concell the automatic starter Press, then press, light off and the automatic stop is off. Note : If the water filtration system is stop before the heat pump, the unit will shut down (security condition) and the code EE3 or ON advertise on the controller. It is important to program the heat pump link the time program of the water filtration system. For restart the heat pump, turn off and turn on the electrical power supply to restart the unit. 12

14 Running data setting Check the parameters On standby or running mode, press for 10 seconds. Afterwards press or to check the parameters (from 0 to H, see operation parameter table). How to adjust the parameters The parameters can only be adjusted in stand-by 1. Long press for 10 seconds, press again to select the data (from 0 to 10#, see operation parameter table) you want to adjust. 2. Press or to adjust the parameter. Press again to store the new data. 3. Press or to select other data that needs to be adjusted and repeat the steps above. 13

15 Press MODE to change mode( Mode only be changed for or parameter 6) Mode can be changed while running Auxiliary electrical heating is not applicable to these modes. 14

16 Current status 15

17 Parameter Meaning Range Default Remarks 0 To set the entering water temp. under cooling mode Adjustable 1 To set the entering water temp. under heating mode Adjustable 2 3 Entry into defrosting time period Terms of Entry defrosting function Minutes -30 to 0 40 Minutes Adjustable -7 Adjustable 4 Terms of Exit defrosting 2 to Adjustable 5 Time of Exit defrosting 6 Mode: 0 Cool 1 Heat and Cool 2 Heat and cool+ auxiliary elec. Heating 3 Heat 1 to 12 minutes 12 minutes Adjustable Adjustable 7 Mode selection of Electronic expansion valve 0-1 1(auto) Adjustable 8 Superheat for target heating Adjustable 9 A Superheat for cooling target Manual adjustment steps of electronic expansion valve Adjustable Adjustable B Inlet water temperature Exact testing by value C outlet gas temperature Exact testing by value D Condenser temperature under heating mode Exact testing by value E Gas return temperature Exact testing by value F Ambient temperature Exact testing by value G H Condenser temperature under Cooling mode Actual steps of electronic expansion valve Exact testing by value N*5 Exact testing by value 16

18 Q&A Error code Malfunction Inlet water temperature sensor failure Exhaust temperature sensor failure Error code PP1 PP2 Reason The sensor in open or short circuit The sensor in open or short circuit Solution Check sensor Check sensor or change the or change the Heating condenser sensor failure PP3 The sensor in open or short circuit Check sensor or change the Gas return sensor failure PP4 The sensor in open or short circuit Check sensor or change the Ambient temperature sensor failure PP5 The sensor in open or short circuit Check or change the sensor Temperature difference between water inlet and outlet is too much PP6 Water flow volume not enough,water pressure difference is too low Check the water flow volume or water jammed or not Cooling outlet water temperature is too low PP7 Water flow volume is not enough Check the water flow or water system is jammed or not First grade antifreeze protection in Winter PP7 Ambient temperature or water inlet temperature is too low Water pump will run automatically for first grade antifreeze Second grade antifreeze protection in Winter PP7 Ambient temperature or water inlet temperature is too low Heat pump will start heating for second grade antifreeze Cooling condenser sensor failure PP8 The sensor in open or short circuit Check or change the sensor High pressure protection EE1 Refrigerant is too much Air flow is not enough Low pressure protection EE2 Refrigerant is not enough Water flow is not enough Filter jammed or capillary jammed Discharge redundant refrigerant from HP gas system Clean the air exchanger Check if there is any gas leakage,re-fill the refrigerant Clean the air exchanger 3.Replace the filter or capillary Flow switch closed EE3 or «ON«Low water flow, wrong flow direction, or flow switch failure Check if the water flow is enough and flow in right direction, or else the flow switch could be failing. 17

19 Power supply connections wrong EE4 Lack of connection Check the connection of the power cable. Inlet and outlet water temperature difference malfunctions Communication failure EE5 Not enough water Check the water flow rate and whether the water system is jammed. EE8 Good Check the wire connection Other malfunctions Malfunctions Observing Reasons Solution Heat pump not running LED wire controller no display No power supply Check cable and circuit breaker LED wire controller displays Heat pump on stand-by Activate heat pump actual time. LED wire controller displays the actual water temperature Water temperature is cooling when HP runs under heating mode Short running Water stains LED wire controller displays actual water temperature and no error in code displays LED displays actual water temperature/no error in code displays Water stains on heat pump unit 1. Water temperature is reaching to the set value, HP under constant 2. Heat pump has just been activated 3. Under defrosting 1. The wrong mode has been chosen 2. Figure shows defects 3. Controller defect 1. Fan is off 2. Air ventilation is not enough 3. Refrigerant is not enough 1. Concreting 2. Water leakage 1. Verify water temperature setting 2. Start-up heat pump after a few minutes 3. LED wire controller should display defrosting 1. Adjust the mode 2. Replace the defect LED wire controller, and check the status after changing the mode. 1. Check the cables between the motor and fan. Replace if necessary. 2. Check the location of the heat pump unit, and eliminate obstacles that could cause obstruction. 3. Replace or repair heat pump unit 1. No action 2. Check whether the heat exchanger has any defects Too much ice on evaporator Too much ice on evaporator 1. Eliminate all obstacles that could cause obstruction 2. Replace or repair the heat pump unit. 18

20 Maintenance o Check the water supply to the unit often. Low water flow and air entering into the system should be avoided, as this will diminish the units performance and reliability. You should clean the pool/spa filter regularly to avoid damage to the unit as a result of the dirty or clogged filter. o The area around the unit should be dry, clean and well ventilated. Clean the side heating exchanger regularly to maintain good heat exchange and to save energy. o Only a certified technician should service the operation pressure of the refrigerant system. o Check the power supply and cable connection often. Should the unit begin to operate abnormally, switch it off and contact a qualified technician. o In winter, please discharge all water from the water pump and other systems to prevent damage from freezing. o Discharge the water at the bottom of the heat pump if the unit will not work for an extended period of time. You should check the unit thoroughly and fill the system with water fully before using it for the first time after a prolonged period of no usage. 19

21 Wiring diagram 20

22

Swimming Pool Heat pump Instruction manual Harmo PAC series (Type ZVWX1017, ZVWX1023, ZVWX1033, ZVWX1042, ZVWX1052, ZVWX1057, ZVWX1062)

Swimming Pool Heat pump Instruction manual Harmo PAC series (Type ZVWX1017, ZVWX1023, ZVWX1033, ZVWX1042, ZVWX1052, ZVWX1057, ZVWX1062) Swimming Pool Heat pump Instruction manual Harmo PAC series (Type ZVWX1017, ZVWX1023, ZVWX1033, ZVWX1042, ZVWX1052, ZVWX1057, ZVWX1062) Imported by : Zwembad BVBA Industrieweg 9 3190 Boortmeerbeek België

More information

SWIMMING POOL HEAT PUMP UNIT ECO - series. Installation & Instruction manual

SWIMMING POOL HEAT PUMP UNIT ECO - series. Installation & Instruction manual SWIMMING POOL HEAT PUMP UNIT ECO - series Installation & Instruction manual Rev. 1.00 28.11.2007 Contents SWIMMING POOL HEAT PUMP UNIT 1 CONTENTS 2 1. PREFACE 3 2. SPECIFICATIONS 4 2.1 Performance data

More information

Harmo Powerpack Horizontal Units Installation & instruction manual

Harmo Powerpack Horizontal Units Installation & instruction manual Imported by: Zwembad BVBA Industrieweg 9 3190 Boortmeerbeek België www.harmopool.eu Harmo Powerpack Horizontal Units Installation & instruction manual Table of content Introduction... 3 Characteristics...

More information

SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual Duratech - series

SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual Duratech - series SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual Duratech - series Rev. 3.32 26.01.2007 CONTENTS 1. Preface 3 2. Specifications 4 2.1 Performance Data of swimming Pool Heat Pump Unit 4 2.2

More information

SWIMMING POOL HEAT PUMP UNIT

SWIMMING POOL HEAT PUMP UNIT SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual A pplicable M odel: YA P S 1-4 5HL YA P S 1-9 0HL YA P S 1-1 40HL YA P S 1-6 5HL YA P S 1-1 20HL 1. Preface * In order to provide our customers

More information

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA OWNER S MANUAL Vintage Classic HEAT COOL models Proudly Made in the USA support@aquacomfort.com www.aquacomfort.com/service-and-support 888-475-7443 Manufacturing High Quality, High Efficiency Heat Pump

More information

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA

OWNER S MANUAL. Models: AC110, AC125, AC150 made from 2003 through Proudly Made in the USA OWNER S MANUAL Models: AC110, AC125, AC150 made from 2003 through 2010 Proudly Made in the USA support@aquacomfort.com www.aquacomfort.com/service-and-support/ (888) 475-7443 Manufacturing High Quality,

More information

MiNI SWIMMING POOL HEAT PUMP UNIT. Installation & Instruction Manual

MiNI SWIMMING POOL HEAT PUMP UNIT. Installation & Instruction Manual MiNI SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual 5.Maintenance and inspection 5.1 Maintenance To check the water supply device and the releaser often. You should avoid the condition

More information

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table) 1 2 Warning: - Do not place your hand or any other objects into the air outlet and fan. It could damage the heat pump and cause injuries; - In case of any abnormality with the heat pump, cut off the power

More information

SWIMMING POOL HEAT PUMP UNIT. Installation & Instruction Manual

SWIMMING POOL HEAT PUMP UNIT. Installation & Instruction Manual SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual CONTENTS. Preface. Specifications. Performance Data of Swimming Pool Heat Pump Unit. Dimensions for Swimming Pool Heat Pump Unit 3. Installation

More information

SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual

SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual OASIS C10 HEAT PUMP Head Office 62 Parkhurst Drive Knoxfield VIC 3180 T: 03 9887 2131 New South Wales Unit 1, 20-22 Foundry Road Seven Hills

More information

Owner s Manual for Swimming Pool Heat Pump

Owner s Manual for Swimming Pool Heat Pump Owner s Manual for Swimming Pool Heat Pump FC Series nirvanahp.com CONTENTS How it works 1 Installation 2 3 Settings 4 5 6 7 Start-up 8 Winterizing 9 Maintenance 10 Troubleshooting 11 12 13 Warranty 14

More information

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA.

OWNER S MANUAL. Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750. Proudly Made in the USA. OWNER S MANUAL Vintage Signature Series models: AC750, AC1050, AC1100, AC1250, AC1500, AC1750 Proudly Made in the USA support@aquacomfort.com 888-475-7443 Manufacturing High Quality, High Efficiency Heat

More information

SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL

SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL MODEL AT105 AT115 AT130 with Titanium Heat Exchanger 2213 Andrea Lane Ft. Myers FL 33912 888-297-3826 941-482-0606 www.aquathermheatpumps.com DIGITAL

More information

SWIMMING POOL HEAT PUMP UNIT. Installation & Instruction Manual

SWIMMING POOL HEAT PUMP UNIT. Installation & Instruction Manual SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual CONTENTS. Preface. Specifications. Performance Data of Swimming Pool Heat Pump Unit. Dimensions for Swimming Pool Heat Pump Unit. Installation

More information

Swimming Pool Heat Pump

Swimming Pool Heat Pump 7018522 Hydro-Pro Heat pump ABS 230V black type 5 horizontal 7018523 Hydro-Pro Heat pump ABS 230V black type 7 horizontal 7018524 Hydro-Pro Heat pump ABS 230V black type 10 horizontal 7018525 Hydro-Pro

More information

INSTALLATION AND USER MANUAL

INSTALLATION AND USER MANUAL INSTALLATION AND USER MANUAL Thank you for choosing our product and trusting our company. This manual is to provide you with necessary information for optimal use and maintenance, please read carefully

More information

Hydro-S Heat pump 230V black type 12horizontal. Swimming Pool HeatPump UserandServicemanual

Hydro-S Heat pump 230V black type 12horizontal. Swimming Pool HeatPump UserandServicemanual 7018517 Hydro-S Heat pump 230V black type 3 horizontal 7018518 Hydro-S Heat pump 230V black type 5 horizontal 7018519 Hydro-S Heat pump 230V black type 8 horizontal 7018520 Hydro-S Heat pump 230V black

More information

Swimming Pool Heat Pump

Swimming Pool Heat Pump Swimming Pool Heat Pump Operation and Installation Manual MODEL FH-020 CONTENTS INTRODUCTION Index............ 2 The unit...... 2 SAFETY INSTRUCTIONS... 4 Electrical Installation Warning.. 4 Location Warning

More information

This manual should be maintained in legible condition and kept adjacent to the heat pump or in a safe place for future use.

This manual should be maintained in legible condition and kept adjacent to the heat pump or in a safe place for future use. Perfectemp Swimming Pool Heat Pump CE OWNER S MANUAL Models PT4, PT6, and PT8 R C LISTE D 9900276 US This manual should be maintained in legible condition and kept adjacent to the heat pump or in a safe

More information

THERMOTEC INVERTER SWIMMING POOL HEAT PUMP

THERMOTEC INVERTER SWIMMING POOL HEAT PUMP THERMOTEC INVERTER SWIMMING POOL HEAT PUMP Installation & Instruction Manual for Horizontal Models 9kw, 12kw, 17kw, 20kw, 24kw Version 4.0 Table of contents 1. Preface 3 2. Specifications 2.1 Performance

More information

INSTALLATION AND USER MANUAL

INSTALLATION AND USER MANUAL Swimming Pool Heat Pump Swimming Pool Heat Pump INSTALLATION AND USER MANUAL Thank you for choosing our product and trusting our company. This manual is to provide you with necessary information for optimal

More information

INSTALLATION AND USER MANUAL

INSTALLATION AND USER MANUAL INSTALLATION AND USER MANUAL t Thank you for choosing Aqua inverter heat pump. This manual provides you necessary information for optimal use and maintenance, please read it carefully and keep it for subsequent

More information

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product. USER MANUAL Portable Air Conditioner and Heater With Heat Pump Technology PAC12 PAC15 PAC18 Please read this manual carefully prior to operating the product. TABLE OF CONTENTS INTRODUCTION... 3 IMPORTANT

More information

Owner's Manual TABLE OF CONTENTS

Owner's Manual TABLE OF CONTENTS 40MAQ High Wall Ductless System Sizes 09 to 36 Owner's Manual TABLE OF CONTENTS PAGE A NOTE ABOUT SAFETY... 2 GENERAL... 2 PART NAMES... 3 FUNCTION BUTTONS... 4 DISPLAY PANELS... 5 REMOTE CONTROL... 6

More information

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different. RADS-51J RADS-61J Owner s Manual Room Air Conditioner with R-410A Heat Controller, Inc. 15 16 Contact an authorized service technician for repair or maintenance of this unit. Contact an authorized installer

More information

5) Do not start or stop the unit by inserting or pulling out the power plug.

5) Do not start or stop the unit by inserting or pulling out the power plug. 3058080 V170306 PURCHASE INFORMATION Thank you for choosing a Soleus Air Portable Air Conditioner. This Owner s Manual will provide you with valuable information necessary for the proper care and maintenance

More information

SWIMMING POOL HEAT PUMP UNIT POMPA DI CALORE PER PISCINA

SWIMMING POOL HEAT PUMP UNIT POMPA DI CALORE PER PISCINA SWIMMING POOL HEAT PUMP UNIT POMPA DI CALORE PER PISCINA SWIMMING POOL HEAT PUMP UNIT CONTENTS 1. Preface 1 2. Spec 2.1 Performance Data of Swimming Pool Heat Pump Unit 2 2.2 Dimensions for Swimming Pool

More information

Owner s Manual PRINTED IN CANADA 05/2009

Owner s Manual PRINTED IN CANADA 05/2009 Owner s Manual PRINTED IN CANADA 05/2009 Table of contents Introduction 2 General Safety Instructions 4 Installation Instructions Location 6 Water piping 7 Electrical 7 Bonding 8 Bonding and plumbing

More information

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

Model No.: PS08-01 PS10-01 Ref: KY80 KY100 8,000/10,000/12,000 BTU Portable Air Conditioner Operating Instructions Model No.: PS08-01 PS10-01 Ref: KY80 KY100 Model No.: PS12-03 Ref: KY120 3119233 V160310 Thank you for choosing a Soleus Air Portable

More information

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU OPERATING INSTRUCTIONS PCR-06-01 PCR-08-01 PCR-10-01 3058080 V170223 PURCHASE INFORMATION Thank you for choosing a Chigo Portable Air Conditioner.

More information

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International 11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions Model No. PE4-11R-03 2006 Soleus Air International Thank you for choosing a Soleus Air Portable Air Conditioner.

More information

SWIMMING POOL HEAT PUMP UNIT POMPA DI CALORE PER PISCINA. Installation & Instruction Manual - p. 1 Manuale di Installazione e d'uso p.

SWIMMING POOL HEAT PUMP UNIT POMPA DI CALORE PER PISCINA. Installation & Instruction Manual - p. 1 Manuale di Installazione e d'uso p. SWIMMING POOL HEAT PUMP UNIT POMPA DI CALORE PER PISCINA Installation & Instruction Manual - p. 1 Manuale di Installazione e d'uso p. 21 SWIMMING POOL HEAT PUMP UNIT CONTENTS 1. Preface 1 2. Spec 2.1 Performance

More information

Owner's Manual TABLE OF CONTENTS

Owner's Manual TABLE OF CONTENTS 40MB*D Ducted Style Ductless System Sizes 09 to 48 Owner's Manual TABLE OF CONTENTS PAGE A NOTE ABOUT SAFETY... 2 GENERAL... 2 PARTS LIST... 3 DISPLAY PANELS... 4 FUNCTION BUTTONS... 5 REMOTE CONTROL...

More information

INSTALLATION AND USER MANUAL

INSTALLATION AND USER MANUAL INSTALLATION AND USER MANUAL Thank you for choosing inverter heat pump. This manual provides you necessary information for optimal use and maintenance, please read it carefully and keep it for subsequent

More information

Swedish design and manufacture since 1967

Swedish design and manufacture since 1967 Swedish design and manufacture since 167 PVP MA20-14 rev.2 Manual User manual Copyright 2017 Pahlén AB, Box 728, SE-14 27 Upplands Väsby, Sweden Tel. +46 8 54 110 50, Fax +46 8 50 868 80, e-mail: info@pahlen.se,

More information

SWIMMING POOL HEAT PUMP Owners Manual

SWIMMING POOL HEAT PUMP Owners Manual SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 5.6kW 9.5kW and 12.5kW models only. The heat pump unit is sold with a 2 year warranty on all components. Please contact your supplying dealer

More information

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology OWNER'S MANUAL Model # KY-34 3046364 Please read owner s manual carefully before operating unit. TABLE OF CONTENTS INTRODUCTION...3

More information

OWNER S Manual PRINTED IN CANADA 10/2009

OWNER S Manual PRINTED IN CANADA 10/2009 OWNER S Manual PRINTED IN CANADA 10/2009 Table of contents Introduction 2 General Safety Instructions 4 Installation Instructions Location 6 Water piping 7 Electrical 7 Bonding 8 Bonding and plumbing

More information

Index. Index. Heatseeker Nova Inverter Heat Pump. Heatseeker Nova Inverter Heat Pump. supremeheating.com.au

Index. Index. Heatseeker Nova Inverter Heat Pump. Heatseeker Nova Inverter Heat Pump. supremeheating.com.au Index Heatseeker Nova Index Heatseeker Nova Index Index 1. GENERAL INFORNMATION 1 1.1 Introduction to Heatseeker Nova 1 1.2 Consumer and Safety Infornmation 2 2. SPECIFICATIONS 3 2.1 Technical Specifications

More information

Owner s Manual TABLE OF CONTENTS

Owner s Manual TABLE OF CONTENTS 40MBDQ Ducted Style Ductless System Sizes 18 to 48 Owner s Manual TABLE OF CONTENTS PAGE A NOTE ABOUT SAFETY... 2 GENERAL... 2 PARTS LIST... 3 DISPLAY PANELS... 4 FUNCTION BUTTONS... 5 REMOTE CONTROL...

More information

User Manual. Nova. Nova+ Inverter Heat Pumps. The National Award Winning. The future of heat pump technology has arrived

User Manual. Nova. Nova+ Inverter Heat Pumps. The National Award Winning. The future of heat pump technology has arrived The National Award Winning Inverter Heat Pumps User Manual Nova Awarded gold for sustainability Nova With even greater performance The future of heat pump technology has arrived NATIONAL Head Office Bundoora

More information

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump R-10A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFF(A/H)H, DFC(A/H) Please read the operating instructions and safety precautions carefully and thoroughly before installing and

More information

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER Instruction Manual Model AMB-12H PLEASE READ THIS INSTRUCTION MANUAL CAREFULLY BEFORE USING THIS UNIT. Table of Contents 1. SAFETY WARNINGS 2 2. CONSTRUCTION...

More information

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36 OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36 TABLE OF CONTENTS PAGE SAFETY PRECAUTIONS... 2 GENERAL... 2 INDOOR UNIT PART NAMES... 3 REMOTE CONTROL PART NAMES...

More information

SWIMMING POOL HEAT PUMP UNIT

SWIMMING POOL HEAT PUMP UNIT SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual Rev. WF PHP 09.06.2017 1.27.1000105 Advice to customers 1. Please read this manual carefully before installing the product, otherwise you

More information

SLIDER CASEMENT AIR CONDITIONER

SLIDER CASEMENT AIR CONDITIONER OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS SLIDER CASEMENT AIR CONDITIONER ROTARY CONTROL P/N 309000854 (11/03) ROOM AIR CONDITIONER WARRANTY Your product is protected by this warranty Your appliance

More information

Inverter Swimming Pool Heat Pump

Inverter Swimming Pool Heat Pump P Inverter Swimming Pool Heat Pump Content I. Application... 2 II. Features... 2 III. Technical Parameter... 3 IV. Dimension... 4 V. Installation instruction... 5 VI. Operation instruction... 9 VII. Testing...

More information

G&F Manufacturing Swimming Pool Heat Pump Install & Operations Manual

G&F Manufacturing Swimming Pool Heat Pump Install & Operations Manual G&F Manufacturing Swimming Pool Heat Pump Install & Operations Manual 5005001B Version 5.2 TABLE OF CONTENTS Introduction 3 Water Chemistry Maintenance 5 Installation o Location of Heater 6 o Tie Downs

More information

INSTALLATION MANUAL. G&F Manufacturing 7902 Interstate Court North Fort Myers, Florida

INSTALLATION MANUAL. G&F Manufacturing 7902 Interstate Court North Fort Myers, Florida INSTALLATION MANUAL G&F Manufacturing 7902 Interstate Court North Fort Myers, Florida Heat Pump Services 990 NW 53rd Street Fort Lauderdale, Florida 33309 G&F Manufacturing 7902 Interstate Court North

More information

Contents. Specifications. Description SV HP 55 SV HP 90. Specifications Warnings Introduction Overview... 4

Contents. Specifications. Description SV HP 55 SV HP 90. Specifications Warnings Introduction Overview... 4 Contents Specifications Specifications... 1 Warnings... 2 Introduction... 3 Overview... 4 Installation Instructions... 5 Cable Connections... 6 Plumbing Diagram... 7 Electrical Wiring Diagram... 8 SV System

More information

SWIMMING POOL HEAT PUMP UNIT. Installation & Instruction Manual

SWIMMING POOL HEAT PUMP UNIT. Installation & Instruction Manual SWIMMG POOL HEAT PUMP UNIT Installation & Instruction Manual ONTENTS. Preface. Specifications. Performance Data of Swimming Pool Heat Pump Unit. Dimensions for Swimming Pool Heat Pump Unit.3 How to disassemble

More information

Operating Instructions

Operating Instructions Operating Instructions Air Conditioner Model No. Indoor Unit CS-E12QD3RW CS-E18QD3RW Single Split Outdoor Unit CU-E12QD3R CU-E18QD3R Multi Split Outdoor Unit CU-4E23QBR CU-4E27QBR CU-5E34QBR Operating

More information

Swimming Pool Heat Pump

Swimming Pool Heat Pump Swimming Pool Heat Pump - Operation and Installation Manual - Model:LCSPI-95BP,LCSPI-135BP,LCSPI-180BP, LCSPI-220BP, LCSPI-280BP TABLE OF CONTENT INTRODUCTION...... 2 This manual... 2 The Heat Pump...

More information

ULTRA LOW TEMPERATURE FREEZER. User Manual

ULTRA LOW TEMPERATURE FREEZER. User Manual ULTRA LOW TEMPERATURE FREEZER User Manual Note:Kaltis reserves the right to modify any parts of this manual without prior notice. 1. No part of this manual may be reproduced in any form, or translated

More information

SWIMMING POOL & SPA HEAT PUMPS INSTALLATION MANUAL

SWIMMING POOL & SPA HEAT PUMPS INSTALLATION MANUAL PROLOGIC CONTROL POWER PROLOGIC CONTROL POWER POOL SPA HEATING POOL SPA HEATING NO WATER FLOW NO WATER FLOW FAULT FAULT POWER POOL SPA HEATING NO WATER FLOW FAULT PROLOGIC CONTROL POWER POOL SPA HEATING

More information

T-Series Air Conditioner T15 Model

T-Series Air Conditioner T15 Model INSTRUCTION MANUAL T-Series Air Conditioner T15 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES) OWNER S MANUAL HIGH WALL INVERTER (English) (BSHVD1S SERIES) IMPORTANT As with any product that has moving parts or is subject to wear and tear, it is VERY IMPORTANT that you maintain your air conditioner

More information

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump R 410A Ductless Split System Air Conditioner and Heat Pump Models DLC4(A/H) Outdoor Unit, DLF4(A/H) Indoor Unit Sizes 9K, 12K, 18K, 24K, 30K and 36K Please read the operating instructions and safety precautions

More information

OWNER S MANUAL HIGH WALL INVERTER. (English) (MSHVD1S SERIES)

OWNER S MANUAL HIGH WALL INVERTER. (English) (MSHVD1S SERIES) OWNER S MANUAL HIGH WALL INVERTER (English) (MSHVD1S SERIES) IMPORTANT As with any product that has moving parts or is subject to wear and tear, it is VERY IMPORTANT that you maintain your air conditioner

More information

Instructions for installation and use English. More documents on: H B /09

Instructions for installation and use English. More documents on:  H B /09 TM Instructions for installation and use English EN More documents on: www.zodiac-poolcare.com H0538700.B - 2015/09 Read this manual carefully before installing, maintaining or repairing this appliance!

More information

AIR CONDITIONER ELECTRONIC CONTROL

AIR CONDITIONER ELECTRONIC CONTROL READ AND SAVE THESE INSTRUCTIONS AIR CONDITIONER ELECTRONIC CONTROL ROOM AIR CONDITIONER WARRANTY Your product is protected by this warranty Your appliance is warranted by Electrolux. Electrolux has authorized

More information

MODEL 598A TWO-SPEED PLUS CENTRAL AIR CONDITIONER

MODEL 598A TWO-SPEED PLUS CENTRAL AIR CONDITIONER USER S INFORMATION MANUAL MODEL 598A TWO-SPEED PLUS CENTRAL AIR CONDITIONER NOTE TO INSTALLER: This manual must be left with the equipment user. WELCOME TO EFFICIENT HOME COOLING COMFORT Congratulations

More information

40KMC KMQ

40KMC KMQ 40KMC------301 40KMQ------301 OWNER S MANUAL Split system Global cassette indoor unit IR Remote Control Room Controller Zone Manager The unit can be used with infrared Remote Control, with the Carrier

More information

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions Model No. GB-PAC-08E4 8,000 BTU Portable Air Conditioner Operating Instructions Thank you for choosing a Soleus Air Powered by Gree Portable Air Conditioner. This owner s manual will provide you with valuable

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A TECHNICAL & SERVICE MANUAL SA 183A FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. SA-183A 1 851 006 96 Destination Australia SA 183A REFERENCE NO. SM700514 IMPORTANT! Please Read Before

More information

EURO APPLIANCES BY EUROSTYLE GROUP

EURO APPLIANCES BY EUROSTYLE GROUP Beverage Cooler EBC 600SX1 EURO APPLIANCES BY EUROSTYLE GROUP Warning The information in this document is subject to modification without any prior notice. This beverage cooler is recommended for indoor

More information

FORCE SERIES SWIMMING POOL HEAT PUMP INSTALLATION AND OPERATION MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING OR OPERATING THE UNIT

FORCE SERIES SWIMMING POOL HEAT PUMP INSTALLATION AND OPERATION MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING OR OPERATING THE UNIT FORCE SERIES SWIMMING POOL HEAT PUMP INSTALLATION AND OPERATION MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE INSTALLING OR OPERATING THE UNIT 1 CHAPTER 1: Installation Chapter 1 deals with installation

More information

OWNER and INSTALLATION MANUAL

OWNER and INSTALLATION MANUAL Raypak RHP Series Swimming Pool and Spa Heat Pump OWNER and INSTALLATION MANUAL Model RHP 33 R C LI ST ED 9900276 US This manual should be maintained in legible condition and kept adjacent to the heat

More information

- 1 - Updated on 18 March, 2010

- 1 - Updated on 18 March, 2010 - 1 - Updated on 18 March, 2010 TABLE OF CONTENTS 1. SPECIFICATION & PARTS IDENTIFICATION...3 2. OPERATION & FUNCTION OF PARTS...4, 5 A. Cooling Operation B. Heating Operation C. Function of Parts 3. LOCATION

More information

Owner s Manual Window Air Conditioner

Owner s Manual Window Air Conditioner Owner s Manual Window Air Conditioner G17-5MCVWAC1 G16-5MCVWAC Write the model and serial numbers below for your records: Model # Serial # Date Purchased Please read the entire manual carefully to ensure

More information

Surna 25-Ton Chiller Operating & Maintenance Manual

Surna 25-Ton Chiller Operating & Maintenance Manual www.surna.com 303.993.5271 Surna 25-Ton Chiller Operating & Maintenance Manual Models: 300F3-3. 300F4-3, 300FW-3 Revised: July 2015 Table of Contents Warranty Information 4 Limited Warranty 4 Limitation

More information

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N T-SERIES Air Conditioner T29 Model INSTRUCTION MANUAL Rev. I P/N 89104464 TABLE OF CONTENTS Warranty and Return Policy...2 IMPORTANT NOTICE...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE

More information

T-Series Air Conditioner T53 Model

T-Series Air Conditioner T53 Model INSTRUCTION MANUAL T-Series Air Conditioner T53 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

SWIMMING POOL HEAT PUMP

SWIMMING POOL HEAT PUMP SWIMMING POOL HEAT PUMP INSTALLATION AND OPERATION MANUAL IMPORTANT It is important to register your product with us on our web site. This will help us find your warranty when you place a service call.

More information

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER Room Air Conditioner Installation and Operation Manual UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER (VOLTS) MIN. MAX. MIN. F ( C) MAX. F ( C) WAC060K7A 127-1-60 114.3 139.7 70(20.1)

More information

TABLE OF CONTENTS FOR YOUR SAFETY

TABLE OF CONTENTS FOR YOUR SAFETY TABLE OF CONTENTS 1. SPECIFICATION & PARTS IDENTIFICATION...2 2. OPERATION & FUNCTION OF PARTS...2, 3 A. Cooling Operation B. Heating Operation C. Function of Parts 3. LOCATION REQUIREMENTS...3, 4 4. INSTALLATION

More information

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL MODEL RA-0LDF RA-3LDF WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL AIR DEFLECTORS VERTICAL DEFLECTORS Vertical de ectors at both sides of outlets can be set to either auto-swing or

More information

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N T-SERIES Air Conditioner T43 Model INSTRUCTION MANUAL Rev. I P/N 10-1008-145 TABLE OF CONTENTS Warranty and Return Policy...2 IMPORTANT NOTICE...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING

More information

!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP. 12,000 BTU Portable Air Conditioner

!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP. 12,000 BTU Portable Air Conditioner _'_j_ii_yg, CI_ ' _i_,_!3 _!!ili_ '_:_i_;iii_ SG-PAC-12E1 SG-PAC- 12E 1HP 12,000 BTU Portable Air Conditioner Operatin! nstructions Thank you for choosing a Soleus Air Powered by Gree Portable Air Conditioner.

More information

ELECTRONIC CONTROL AIR CONDITIONER

ELECTRONIC CONTROL AIR CONDITIONER USE & CARE MANUAL NOTE: This USE & CARE MANUAL provides specific operating instructions for your model. Use the room air conditioner only as instructed in this USE & CARE MANUAL. These instructions are

More information

- 1 - Updated on 18 March, 2010

- 1 - Updated on 18 March, 2010 - 1 - Updated on 18 March, 2010 TABLE OF CONTENTS 1. SPECIFICATION & PARTS IDENTIFICATION...3 2. OPERATION & FUNCTION OF PARTS...4, 5 A. Cooling Operation B. Heating Operation C. Function of Parts 3. LOCATION

More information

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY π H-6621 INDUSTRIAL DEHUMIDIFIER 1-800-295-5510 uline.com WARNINGS Plug into a grounded 3 prong outlet. Do not remove ground prong. Do not use an adapter. Do not use an extension cord if possible. Failure

More information

USER S MANUAL HSC-14/18/24/24A

USER S MANUAL HSC-14/18/24/24A AIRREX AIR CONDITIONER USER S MANUAL HSC-14/18/24/24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available.

More information

Owner s Manual & Installation Guide. Model 525S Model 525TI Model 650TI Model 650SC Model 700TI

Owner s Manual & Installation Guide. Model 525S Model 525TI Model 650TI Model 650SC Model 700TI Owner s Manual & Installation Guide Model 525S Model 525TI Model 650TI Model 650SC Model 700TI KOPEC Enterprises, Inc., located in Pompano Beach, Florida, designs and manufactures the industry's most cutting-edge

More information

SWIMMING POOL HEAT PUMP UNITS. Installation & Instruction Manual EU - series

SWIMMING POOL HEAT PUMP UNITS. Installation & Instruction Manual EU - series SWIMMING POOL HEAT PUMP UNITS Installation & Instruction Manual EU - series Rev. 2.00 20.12.2010 Contents SWIMMING POOL HEAT PUMP UNITS 1 Contents 2 1. Preface 3 2. Specifications 4 2.1 Technical data

More information

ROTARY CONTROL AIR CONDITIONER

ROTARY CONTROL AIR CONDITIONER USE & CARE MANUAL NOTE: This USE & CARE MANUAL provides specific operating instructions for your model. Use the room air conditioner only as instructed in this USE & CARE MANUAL. These instructions are

More information

Bulletin (Jan 2011) And User s Guide

Bulletin (Jan 2011) And User s Guide Bulletin 30 32 (Jan 2011) Unichiller Installation And User s Guide Customer Service If you have questions about Installation, operation and Maintenance of the Unichiller or would like to order replacement

More information

REG-183J REG-253J RADS-151J RADS-183J RADS-253J RAD-283J

REG-183J REG-253J RADS-151J RADS-183J RADS-253J RAD-283J REG-183J REG-253J RADS-151J RADS-183J RADS-253J RAD-283J Owner s Manual Room Air Conditioner with R-410A Heat Controller, Inc. NOTE 1 Heat Controller, Inc. Room Air Conditioner with R-410A Owner s Manual

More information

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N SPECTRACOOL Air Conditioner N21 Model INSTRUCTION MANUAL Rev. G P/N 89115088 TABLE OF CONTENTS WARRANTY AND RETURN POLICY...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N PROAIR Air Conditioner CR23 Model INSTRUCTION MANUAL Rev. D P/N 89112522 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

Portable Air Conditioner. Instruction Manual

Portable Air Conditioner. Instruction Manual Portable Air Conditioner Instruction Manual YPL3-08C Please read the instructions completely before using this product This product is designed for household use only. FOR SERVICE : CALL TRANS GLOBAL SERVICE

More information

T-Series Air Conditioner T20 Model

T-Series Air Conditioner T20 Model INSTRUCTION MANUAL T-Series Air Conditioner T20 Model Protecting Electronics. Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200

More information

Pool & Spa The Duratech Heat Pumps

Pool & Spa The Duratech Heat Pumps Pool & Spa The Duratech Heat Pumps The ideal solution for heating your swimming pool and spa. Bosta... Creating Connections Bosta, pipeline Components for Pools Spas and much much more... Introducing the

More information

ULTRATEMP TM HX HIGH PERFORMANCE HEAT PUMP

ULTRATEMP TM HX HIGH PERFORMANCE HEAT PUMP ULTRATEMP TM HX HIGH PERFORMANCE HEAT PUMP Should the installer or owner be unfamiliar with the correct installation or operation of this type of equipment, you should contact the distributor/manufacturer

More information

NEWGATE TECHNOLOGIES, INC.

NEWGATE TECHNOLOGIES, INC. www W.newgatetechnologies.com NEWGATE TECHNOLOGIES, INC. Installation & Operations Manual SYNERGY Series High Inlet Temperature Refrigerated Air Dryers Models SYNERGY 025 ~ SYNERGY 125 Includes Safety

More information

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions INSPECTION When the equipment is received, all items should be carefully checked against the bill

More information

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions OWNER S MANUAL Operating and Servicing Instructions CR13000-PAC PORTABLE AIR CONDITIONER with HEAT PUMP Portable Air Conditioner Questions or concerns? For assistance, please call Customer Service ClimateRight

More information

INSTALLATION AND USER MANUAL for your heat pump

INSTALLATION AND USER MANUAL for your heat pump INSTALLATION AND USER MANUAL for your heat pump Models 120 / 150 / 200 / 280 2 Thank you Dear Customer, Thank you for your purchase and for your confidence in our products. These are the result of many

More information

PORTABLE AIR-CONDITIONER MODEL: EPAC-A4010D(WH) Owner s Manual Please read this manual carefully before operating your set.

PORTABLE AIR-CONDITIONER MODEL: EPAC-A4010D(WH) Owner s Manual Please read this manual carefully before operating your set. PORTABLE AIR-CONDITIONER MODEL: EPAC-A4010D(WH) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference. Record model number and serial number of the

More information