Insert Manual. DES Series WARNING. For Your Safety
|
|
- Mercy Caldwell
- 5 years ago
- Views:
Transcription
1 Insert Manual For complete installation instructions, see the Tube Heater General Manual that accompanies this Series Insert Manual. The Infra-Red Tube Heater is a positive pressure, single-stage radiant heater system. This insert manual is a supplement to the Tube Heater General Manual and provides specific information related to the model. All persons involved with the installation, operation and maintenance of the heater system must read and understand the information in this insert manual and the Tube Heater General Manual accompanying this insert.! WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operation and maintenance instructions thoroughly before installing or servicing this equipment. This heater must be installed and serviced by trained gas installation and service personnel only. Failure to comply could result in personal injury, asphyxiation, death, fire or property damage. In locations used for the storage of combustible materials, signs must be posted to specify the maximum permissible stacking height to maintain the required clearances from the heater to the combustibles. Signs must either be posted adjacent to the heater thermostats or in the absence of such thermostats, in a conspicuous location. t for residential use! Do not use this heater in the home, sleeping quarters, attached garages, etc. Installation of a commercial tube heater system in residential indoor spaces may result in property damage, serious injury, asphyxiation or death. For Your Safety If you smell gas: Do not try to light any appliance. Immediately call your gas supplier from a neighbor s phone. Do not touch any electrical switch. Follow the gas supplier s instructions. Do not use any phone in your building. If you cannot reach your gas supplier, call the fire department. Keep these instructions for future reference. Form. LIODESa-1M-2/07 (MWG) Replaces Form. LIODES-2M-10/04
2 Contents 1.0 Safety Safety Labels and Locations Clearances to Combustibles Installation Electrical Requirements Wiring Specifications Tube Installation Sequence Operation Sequence of Operation Thermostat Troubleshooting Guide Parts Components Parts List Kit Contents Check List Approvals Limited Warranty NOTE: See page 10 for a list of available models and specifications. 2
3 1.0 Safety Safety Labels and Locations 1.0 Safety Read and understand all safety information and warnings in this insert manual and the Tube Heater General Manual before installation, operation and maintenance of the radiant tube heater system. Safety Labels and Their Locations Product safety signs or labels should be replaced by the product user when they no longer are legible. Contact either your local distributor or the product manufacturer for obtaining replacement signs or labels. Back Panel VOLTS AC AIR METERING ORIFICE FOR INDOOR INSTALLATION ONLY INPUT BTU/H FOR USE WITH 125,000 NAT GAS 60Hz 120V Manifold Pressure 3.5in. W.C.P. Max. Inlet Pressure 14.0in. W.C.P. Min. Inlet Pressure for 5.0in. Purpose of Input Adjustment AMPS - Starting 1.7 Min. Mounting Angle AMPS - Running 1.1 Max. Mounting Angle Heater Type: C1 Combustion Chamber DETROIT RADIANT PRODUCTS CO HOOVER ROAD - WARREN, MI (586) Rating Plate RE-VERBER-RAY INFRA-RED RADIANT TUBE HEATER RE-VERBER-RAY INFRA-RED RADIANT TUBE HEATER FOR INDOOR INSTALLATION ONLY MODEL NO. DES N DESIGN COMPLIES WITH: ANS Z83.20b-2003-GAS FIRED LOW INTENSITY INFRA-RED HTR. MODEL NO. INPUT BTU/H FOR USE WITH DES HL N 125,000 / 95, ,000 NAT GAS W.C.P. 0 DEGREES 45 DEGREES 4 BC Aluminized Serial. 0603DETR DESIGN COMPLIES WITH: ANS Z83.20b-2003-GAS FIRED LOW INTENSITY INFRA-RED HTR. AIR METERING ORIFICE DO NOT REMOVE VOLTS AC DO NOT REMOVE 60Hz AMPS - Starting 1.7 AMPS - Running F/N: LLTB008 M SA 120V Heater Type: LE Manifold Pressure 3.5in. Max. Inlet Pressure 14.0in. W.C.P. P Min. Inlet Pressure for 5.0in. Purpose of Input Adjustment W.C.P. W.C.P. 4.8 Min. Mounting Angle 0 DEGREES 1.1 Max. Mounting Angle 45 DEGREES C1 Combustion Chamber 4 BC Aluminized For Stainless Steel Upgrades the Combustion Table is upgraded to 409 Stainless Steel DETROIT RADIANT PRODUCTS CO HOOVER ROAD - WARREN, MI (586) Serial. 0603DETR F/N: LLTB018 (Natural Gas) F/N: LLTB019 (LP Gas) Top Panel HL N DES Production Code: DES HL2-125 Version: 5/05 F/N: LLTB021 Clearance to Combustibles Label. Serial #: 0603DETR Stock: N/A Add-On Option(s): ne Data on this label is for the model shown on this label. If your heater has been converted, this information is not correct. Please contact the factory for assistance. BURNER COMPNENTS (Specify TP - # s) 36E N ne 840 Relay: Gas Valve: Circuit Board: Micro60-24 Wire Harness: 3 PCS Harness 851 Filter: Volt In: LE N.C. Switch: ne N/A Extra VL Orifice: ne N.C. VL Orifice: ne Diff Switch: IS F E Igniter: rton AM Diff VL Orifice: Grey (+/-) High Burner: 16 Tube: Ind Lights: Diag Light: Term Block: Transfomer: S Fan: Stnd. Yellow - 24V Red LED N/A ne VA Fasco Lg. Alternate Fan: 50Hz - 120V Alt. Fan Usage: When Specified 55A 55B Orifice Type C1 C2 C3 Air: TP44-# 1 1/2 1 5/8 1 5/8 Gas: TP204-# 3 3 P 1 2x4 Box 66 TUBE COMBINATION / KIT PARTS Item Standard Combustion: TP-26A Radiant: TP-26A Clamp: Hangers: RCS: Reflector: Endcap: Baffle: Special 2: Tag: TP-21B TP-19B Stainless Steel TP-26E TP-26D TP-21O TP-19B-SS TP-82 TP-82-SS TP-105 TP-105-SS TP-20C TP-20C-SS TP R For Internal Use Only ID: Electric: Special 1: Your Heater is: C1 Bottom Panel N/A 120 Volt In: Gas In: N/A 3T - plug ne N.O. VL Orifice: ne N/A ne 7/8 FC Flare N.O. Switch: Re-Verber-Ray LLWT38 Micro60 Plug-Wh. ne For all Standard Labels See Board Contact factory at for parts information and list prices. Or visit F/N: LLLOGO1 3 Burner Control Box Component Label (located under the top panel)
4 SERVICE ACCESS PANEL IGNITER & FLAME SENSE COMPARTMENT 1. Turn off gas & electricity. 2. Remove cover by lifting top cover upward and outward. THIS 10 TUBE IS THE COMBUSTION CHAMBER. THE COMUSTION CHAMBER UTILIZES EITHER 409 STAINLESS TITANIUM OR ALUMINIZED STEEL - DEPENDING UPON THE MODEL NUMBER OF YOUR HEATER THIS TUBE MUST BE THE FIRST TUBE FOLLOWING THE BURNER BOX. MOUNT WELDED SEAM TO BOTTOM CONSULT IOM OR PACKAGING STICKER FOR DETAILS (This is the Second Chamber) This tube is constructed of aluminized coated steel and must be placed directly after the titanium coated Combustion Chamber (orange labeled tube) Used on Models: XTS, DET(-3), DES(-3) ( MBH) ONLY 1.0 Safety Safety Labels and Locations Clearance to Combustibles 16 Burner Tube Primary Combustion Chamber Radiant Emitter or Secondary Combustion Chamber (if applicable) CAUTION: HOT SURFACE. KEEP COVER IN PLACE. REMOVE FOR SERVICE ONLY. INSTALLER ***AVOID EQUIPMENT FAILURE*** ALUMINIZED TUBE Right Panel (Valve Compartment)! WARNING AVOID SERIOUS INJURY, DEATH OR PROPERTY DAMAGE. Maintain Clearances to Combustibles to Prevent the Risk of Fire. Clearances to combustibles must be maintained in order to prevent the ignition of combustible materials. In locations used for the storage of combustible materials, signs must be posted to specify the maximum permissible stacking height to maintain the required clearances from the heater to the combustibles. Signs must either be posted adjacent to the heater thermostats or in the absence of such thermostats in a conspicuous location. Clearances are provided on the heater s safety labels and in the heater s Installation & Operation Manual. Refer to applicable ANSI or NFPA-54 Standards or local codes for further information. Post this tag adjacent to the heater s thermostat or controls before operating the heater. INSTALLER. READ AND POST THIS NOTICE. F/N: LL01 - Clearance Safety Tag (Affix adjacent to heater s thermostat). SERVICE ACCESS PANEL IGNITER & FLAME SENSE COMPARTMENT 1. Turn off gas & electricity. 2. Remove cover by lifting top cover upward and outward. CAUTION: HOT SURFACE. KEEP COVER IN PLACE. REMOVE FOR SERVICE ONLY. F/N: LLTB026 INSTALLER ***AVOID EQUIPMENT FAILURE*** THIS 10 TUBE IS THE COMBUSTION CHAMBER. THE COMUSTION CHAMBER UTILIZES EITHER 409 STAINLESS, TITANIUM OR ALUMINIZED STEEL - DEPENDING UPON THE MODEL NUMBER OF YOUR HEATER THIS TUBE MUST BE THE FIRST TUBE FOLLOWING THE BURNER BOX. MOUNT WELDED SEAM TO BOTTOM CONSULT IOM OR PACKAGING STICKER FOR DETAILS F/N: LLTB004 (orange) ALUMINIZED TUBE (This is the Second Chamber) This tube is constructed of aluminized coated steel and must be placed directly after the titanium coated Combustion Chamber (orange labeled tube). Clearance to Combustibles Placement of explosive objects, flammable objects, liquids and vapors close to the heater may result in explosion, fire, property damage, serious injury or death. Do not store or use explosive objects, liquids and vapor in the vicinity of the heater. Clearance to combustibles is defined as the minimum distance that must exist between the tube surface, or reflector, and any combustible items (see Figure 1.1). It also pertains to the distance that must be maintained from moving objects around the tube heater. When installing the tube heater system, clearances to combustibles for the Series tube heater and configuration must be maintained. Refer to Chart 1.1 on the following page to determine the required distances for your model. 4
5 1.0 Safety Clearance to Combustibles Chart 1.1 Clearance to Combustibles in Inches (see Figure 1.1 for Mounting Angles) Mounting Sides Model Number Angle * Front Behind Top Below DES (20, 30, 40) - (50, 60) [N, P] with 1 side shield with 2 side shields ft. from burner DES (20, 30, 40) - 75 [N, P] with 1 side shield with 2 side shields ft. from burner DES (30, 50, 40) [N, P] with 1 side shield with 2 side shields ft. from burner DES (40, 50, 60) [N, P] with 1 side shield with 2 side shields ft. from burner DES (40, 50, 60) [N, P] with 1 side shield with 2 side shields ft. from burner DES (50, 60) [N, P] with 1 side shield with 2 side shields ft. from burner DES (50, 60) [N, P] with 1 side shield with 2 side shields ft. from burner Heaters mounted on an angle between 0 to 45 must maintain clearances posted for 0 or 45 ; whichever is greater. * Figure 1.1 Mounting Angles 0 Mounting Angle 45 Mounting Angle Top Top 0 Mounting Angle with 1 Side Shield Top 0 Mounting Angle with 2 Side Shields Top Side Side Front Behind Front Behind Side Side Below Below 5 Below Below
6 2.0 Installation Electrical Requirements 2.0 Installation Instructions for the following are detailed in the Tube Heater General Manual: te: Electronic versions of all manuals are available at Design considerations Hanger suspension and placement Tube layout and assembly Burner control box suspension Reflectors (and accessories) Venting and combustion air intake Gas requirements Baffle assembly Electrical Requirements NOTICE It is recommended that the thermostat be installed on the hot side of a fused supply line and have sufficient amphere rating for the heater(s) that it controls. 120 Volt - 60 Hz, 3-wire. 120 Volt thermostat connection. Starting current 1.7 amps Running current 1.1 amps! WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, serious injury or death. Read and understand, the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. Only trained, qualified gas installation and service personnel may install or service this equipment. t for residential use! Do not use this heater in the home, sleeping quarters, attached garages, etc. Installation of a commercial tube heater system in residential indoor spaces may result in property damage, serious injury or death. 6
7 2.0 Installation Wiring Wiring! WARNING Electric Shock Field wiring to the tube heater must be connected and grounded in accordance with national, state, provincial, local codes and to the guidelines in the Detroit Radiant General and Series manuals. In the United States refer to the most current revisions to the ANSI/NFPA 70 Standard and in Canada refer to the most current revisions the CSA C22.1 Part I Standard. Figure 2.1 Field Wiring Diagrams A. 120V Thermostat Connection(s). Heaters on the same vent must share the same thermostat. NOTE: Up to 10 line voltage tube heaters can be wired to 22 amp thermostat. L1 Neutral T Additional heaters Ground 120V-60 Hz. Supply DES Burner Box DES Burner Box B. 24V Thermostat Control (requires optional combination relay transformer P/N: R8285B). Common required for thermostats that require constant power White 24V Thermostat 115V To Heater Branch #1 G W R 24V 24V White 115V To Heater Branch #2 Field Supplied NOTE: The transformer relay selected must be capable of handling the combined start-up amperage per relay branch. Pole #2 Pole #1 W R G Coil Y C W B L2 N 115V A transformer relay is used in conjunction with most low voltage thermostats when wiring tube heaters. 7
8 2.0 Installation Wiring Before field wiring this appliance - Check existing wiring; replace if necessary. NOTE: If any of the original wire as supplied with the appliance must be replaced, it must be replaced with wiring material having a temperature rating of at least 105 C. Figure 2.2 Internal Wiring Diagrams A. DES Ladder Diagram L1 120VAC N BK Blower BK BK BK Pressure Switch R Ignitor/ Sensor W GAS VALVE G W G GND VALVE NEUT TH NEUT SENSE Ignition Module R Y B. DES Block Diagram BK + Ignitor/ Sensor L1 BK BK Pressure Switch BK Burner 120VAC N W Y BK M 1 R C 2 W Blower G NO P 3 M 1 C 2 P 3 R W G SENSE NEUT TH NEUT VALVE GND Ignition Module Spark OFF Gas Valve 8
9 2.0 Installation Wiring This page intentionally left blank. There are no alternative wiring diagrams for the 9
10 2.0 Installation Product Specifications Chart 2.1 Specifications Model Number Gas Type (Select One) BTU/H Straight Length (Dim. A) U-Tube Length (Dim. B) Weight (lbs.) Recommended Mounting Heights^ 4 Combustion Chamber(s) (Black Coated) 4 Radiant Emitter Tube(s) (Uncoated) Radiant Surface Area (sq. ft.) 36 Baffle Sections DES N or LP 50, to 14 Aluminized Hot-rolled DES N or LP 60, to 15 Aluminized Hot-rolled DES N or LP 75, to 18 Aluminized Hot-rolled DES N or LP 50, ** to 15 Aluminized Hot-rolled DES N or LP 60, ** to 18 Aluminized Hot-rolled DES N or LP 75, ** to 20 Aluminized Hot-rolled DES N or LP 100, ** to 23 Aluminized Hot-rolled DES N or LP 50, to 18 Aluminized Hot-rolled DES N or LP 60, to 18 Aluminized Hot-rolled DES N or LP 75, to 20 Aluminized Hot-rolled DES N or LP 100, to 23 Aluminized Hot-rolled DES N or LP 125, to 25 Aluminized Hot-rolled DES N or LP 150, to 27 Titan/Alum Hot-rolled DES N or LP 100, ** to 27 Aluminized Hot-rolled DES N or LP 125, ** to 27 Aluminized Hot-rolled DES N or LP 150, ** to 30 Titan/Alum Hot-rolled DES N or LP * 175, ** to 35 Titan/Alum Hot-rolled DES N or LP * 200, ** to 40 Titan/Alum Hot-rolled DES N or LP 125, to 30 Aluminized Hot-rolled DES N or LP 150, to 35 Titan/Alum Hot-rolled DES N orlp * 175, to 35 Titan/Alum Hot-rolled DES N or LP * 200, to 40 Titan/Alum Hot-rolled * Model requires stainless steel tube clamp (P/N: TP-220) to be located at the seam between the primary combustion chamber and the secondary combustion tube downstream of the burner control box. ** Model requires 5EA-SUB accessory package when installing in a U configuration (P/N: TF1B). ^ Factory recommended mounting heights are listed as a guideline. 10
11 2.0 Installation Tube Sequence Heater Length Figure 2.4 Tube Installation Sequence Important! The combustion chamber & radiant tube sections must be installed in the following order. 20 Foot 30 Foot 40 Foot 50 Foot Stainless Steel Clamp on MBH models (P/N: TP-220). 60 Foot Stainless Steel Clamp on MBH models (P/N: TP-220). Key Burner Control Box with 16 Burner Tube Primary Combustion Chamber Tube Secondary Aluminized Combustion Chamber Tube ( MBH Models Only) Uncoated Hot-rolled Steel Radiant Emitter Tube Standard Tube Clamp Stainless Steel Tube Clamp (P/N: TP-220) MBH models only - Located between 1st and 2nd 10 ft. tube sections. Baffle Location te: Refer to the Tube Heater General Manual, Chart 3.6 (page 22) for secured reflector joints. 11
12 3.0 Operation Sequence of Operation Thermostat Diagnostics 3.0 Operation! WARNING NOTE: Reference the Tube Heater General Manual (LIOGTa) for installation requirements. Sequence of Operation This heater must be installed and serviced by trained gas installation and service personnel only. Do not bypass any safety features or the heater s built in safety mechanisms will be compromised. Starting Circuit: Upon a call for heat, the fan is energized. Once operational static pressure is achieved, the differential switch will close, allowing power to the control and initiating the ignition sequence. After a 7-second pre-purge, the spark electrode is energized and the gas valve opens simultaneously. The trial for ignition is 15 seconds. If flame is not sensed, the heater will attempt two (2) additional times to re-ignite with 15-second interpurge periods. Single Stage Running Circuit: After ignition, the flame rod monitors burner flame. If sense of flame is lost, the control immediately acts to reignite the gas-air mixture (identical to the starting sequence). If flame sense is not established within 15 seconds, the heater will attempt two (2) additional ignition sequences before proceeding to hard lockout. The control can be reset by briefly interrupting the power source. Thermostat NOTE: Different thermostats operate according to their particular features. Refer to thermostat specifications. 12
13 3.0 Operation This page intentionally left blank. 13
14 4.0 Troubleshooting Guide 4.0 Troubleshooting Guide Turn up thermostat Find the source of the electrical problem. Remove obstruction and lubricate blower. Does the fan blower turn on? Is the power at the heater 120V? Is the blower obstructed? Replace ignitor. Adjust gap. Does the ignitor spark? Is the ignitor physically damaged? Check the gap on the ignitor. Is the gap between 3/16 and 1/4? During the ignition trial, does the gas valve open? Test for 120V at the gas valve during valve opening (typically 10 seconds after power to the heater). Is there 120V to the valve? The circuit board and/or wiring harness could be faulty. These should be replaced Replace gas valve. Check that gas pressure is within minumum and maximum inputs as indicated on the heater s rating plate. Is gas pressure ok? Correct problem. Does the burner light? Is the ball valve in the ON position? Turn Knob on ball valve to the ON position. Continued on page
15 * NOTICE 4.0 Troubleshooting Guide Bypassing any switch is intended for testing purposes only. Do not leave switch bypassed during normal operation or the heater s built-in safety mechanisms will be compromised. Key Correct wiring or replace relay. Start Question Process Question Corrective Action Is there 120V coming to the fan? The blower is faulty and must be replaced. Remove obstruction Is the inlet or outlet of the unit obstructed? i.e. ice, birds nest, dirt, etc. Check for loose wiring or restrictions in hose connections to the pressure switch. Are they ok? Repair wiring or hose connections. * While the switch is temporarily bypassed, check for 120V from the switch to the circuit board. Does 120V enter the circuit board? The heater is equipped with a safety differential pressure switch. The switch is a normally open switch and is located in the air chamber. Temporarilly place a jumper across the terminal of the switch. Does the ignitor spark? Faulty wiring. Repair or replace wiring. Replace circuit board. Replace the pressure switch after verifying the following: Baffle(s) is in the tube farthest from the burner. Heater, blower, squirrel cage, intake and exhaust are clean and free from dirt and obstructions. The 4 air intake pipe does not exceed 20 ft. and/or two elbows. There is not a negative pressure experienced at the area of air intake (i.e. attic space, high winds, very tight buildings, etc.) If any of the above were occuring, please address the problem. 15
16 4.0 Troubleshooting Guide Continued from page 14. Check that gas pressure is within minumum and maximum inputs as indicated on the heater s rating plate. Is gas pressure ok? Make sure gas lines were purged of air and/or correct pressure problems. Correct problem. Does the burner stay on? Does the burner stay on briefly and then shut off? Is the heater properly grounded? Is the polarity correct? Does the heater stay on until the call for heat ends? Check the gap on the ignitor. Is the gap between 3/16 and 1/4? Adjust gap. Troubleshooting ends. The following can cause the heater to shut down: Improper grounding. High winds. Taking combustion air from the attic. Dirty environment. Baffle not located properly. Fluctuating gas pressure. 16
17 Check the gap on the ignitor. Is the gap between 3/16 and 1/4? Adjust gap. Check that flame sensor wire is OK and then replace circuit board. With microammeter, check amperage at flame rod. Is it greater than 0.7 microamps? Check that gas pressure is within minumum and maximum inputs as indicated on the heater s rating plate. Is gas pressure ok? Correct Problem Sensing Rod is faulty or flame is weak. Check that heater is operating at proper gas pressure as indicated on the heaters rating label. Clean or replace electrode if needed. Differential switch may be faulty or there is a restriction in the exhaust or intake. 17
18 5.0 Parts Heater Components and Parts List 5.0 Parts Figure 5.1 Burner Assembly Components APS 55A B 68A B A or 201B B B or 209P Chart 5.1 Parts List Part # Description Part # Description TP-1 Control Box Cover TP-26C 10 Ft. Uncoated Hot Rolled Radiant Tube TP-5 Flange Gasket TP-31B Control Box Mounting Bracket TP-9 Conduit Coupling TP-44 Metal Air Orifice w/ Screen - Consult Factory TP-10 Conduit TP-55A Fan Blower TP-11 Ignitor Box TP-65I Interlocking 36 Turbulator Baffle Section TP-12 Ignitor Box Cover TP-68A Strain Relief Bushing TP-13 8 x 1/2 Self-Drilling Screw TP-70 Control Box Cover Gasket (**per foot) TP-14 Sight Glass Gasket TP-76 Rubber Grommet TP-15 Sight Glass TP-82 Reflector Center Support TP-16 Sight Glass Washer TP-97 1/4 x 1/4 Brass Int./Ext. Atmos. Barb Fitting TP-17 Sight Glass Kit TP Ft. Coated Alum-Titan Tube w/ Clamp TP-20C 10 Ft. Aluminum Reflector TP Ft. Coated Aluminized Tube w/ Clamp TP-20D 10 Ft. Optional 304 Stainless Steel Reflector TP Ft. Aluminum Reflector TP-21B 4 Tube Clamp TP-114 Plastic Air Orifice - Consult Factory TP-26A 10 Ft. Aluminized Combustion/Radiant Tube TP-122 Gasket for Air Orifice and Air Collar TP-26B 10 Ft. Titanium Treated Combustion Tube TP-200A Burner ( MBH) 18
19 5.0 Parts Heater Components and Parts List Figure 5.2 Tube & Reflector Components 20C, 20D 82 26C Radiant Emitter Tubes(s) 579 Combustion Tubes(s) 21B, I 26A, 26B Part # Description Part # Description TP-201B Burner ( MBH) TP-502 Left End Panel TP-204 Gas Orifice - Consult Factory TP-503 Right End Panel TP-207 Pressure Switch Mounting Bracket TP-504 Control Box Shell TP-208 Z Mounting Bracket TP-550 Spark Transfer Wire - Orange TP E36A-246 Gas Valve Assembly - Natural Gas TP-551 MARK 10DX-117 DSI Circuit Board w/ Pre-Purge TP-209P 36E36A-240 Gas Valve Assembly - LP Gas TP-552 Wiring Harness TP-212 1/2 x 3 Pipe Nipple TP-553 Spark Ignitor Mounting Bracket TP-217 Pressure Barb Fitting TP-554 Spark Ignitor Mounting Bracket Gasket TP-218 Vinyl Differential Exhaust Sensing Tube TP-555 Spark Ignitor Electrode TP-219 Vinyl Differential Burner Sensing Tube TP Wire Hanger TP Stainless Steel Tube Clamp TP-223 Gas Manifold APS Select Pressure Switch Below (BTU Dependent) TP-331 Green Self-Tap Ground Screw (TP-264B) Atmospheric Pressure Switch (50 to 100 MBH) TP Burner Tube with Flange (TP-264E) Atmospheric Pressure Switch (125 to 150 MBH) TP-383B Spark Ignitor Plate (TP-264D) Atmospheric Pressure Switch (175 MBH) TP-501 Divider Panel (TP-264F) Atmospheric Pressure Switch (200 MBH) 19
20 5.0 Parts Kit Contents Check List Kit Contents Check List Chart 5.3 Kit Contents for - Reference the length column for your model. Kit Contents TP Wire Hanger TP-82 4 Reflector Center Support (RCS) TP-21B 4 Tube Clamps* General Manual and Insert F/N: LIOGTa & LIODESa Tube Heater General Manual Insert Manual Part. Description 20 ft. 30 ft. 40 ft. 50 ft. 60 ft. TP Hanger TP-21B 4 Tube Clamps * 6* TP-82 4 Reflector Center Support LIO - - General Manual & Insert Manual /2 Shut-Off Valve & Inlet Tap 24 S.S. Flexible Gas Connector F i e l d S u p p l i e d F i e l d S u p p l i e d Filled By: * One 4 stainless steel tube clamp (P/N: TP-220) is provided for each 175, ,000 BTU model. Place as shown on page 11. Approvals CSA Design Certified Commercial/Industrial approval. Limited Warranty 1 year - Burner box components. 2 years - Combustion and radiant tubes. 3 years - Stainless steel burner. See page 36 of the General Tube Heater Manual for Terms and Conditions Detroit Radiant Products Co Hoover Road Warren, MI Phone: Fax: sales@detroitradiant.com Printed in U. S. A. 20
Insert Manual. DET3 Series WARNING. For Your Safety
Insert Manual For complete installation instructions, see the Tube Heater General Manual that accompanies this Series Insert Manual. The Infra-Red Tube Heater is a positive pressure, two-stage radiant
More informationTypical Mount Height. Combustion Chamber
! WARNING: This heater must be installed and serviced by trained gas installation and service personnel only! Improper installation, adjustment, alteration, service or maintenance can cause property damage,
More informationInsert Manual. RHT Series WARNING. For Your Safety
RHT Series Insert Manual For complete installation instructions, see the Tube Heater General Manual that accompanies this Series Insert Manual. The RHT Series Infrared Tube Heater is a positive pressure,
More informationInsert Manual. SV Series WARNING. For Your Safety
Insert Manual For complete installation instructions, see the Tube Heater General Manual that accompanies this Series Insert Manual. The Infrared Tube Heater is a negative pressure, single-stage radiant
More informationInsert Manual. XTS3 Series WARNING. For Your Safety. For complete installation instructions, see the General Manual that accompanies this insert.
Insert Manual For complete installation instructions, see the General Manual that accompanies this insert. The Infrared Tube Heater is a positive pressure, single-stage radiant heater system. This insert
More informationFor complete installation instructions, reference the Tube Heater General Manual that accompanies this insert manual.
Insert Manual For complete installation instructions, reference the Tube Heater General Manual that accompanies this insert manual. The Infrared Tube Heater is a positive pressure, single-stage radiant
More informationInsert Manual. RVA2 Series WARNING. For Your Safety
Insert Manual For complete installation instructions, see the Tube Heater General Manual that accompanies this Series Insert Manual. The Infrared Tube Heater is a positive pressure, two-stage radiant heater
More informationInsert Manual. DX3 Series WARNING. For Your Safety
DX3 Series Insert Manual For complete installation instructions, see the Tube Heater General Manual that accompanies this insert manual. The DX3 Series Infrared Tube Heater is a positive pressure, single-stage
More informationInsert Manual. DES3 Series WARNING. For Your Safety
Insert Manual For complete installation instructions, see the Tube Heater General Manual that accompanies this Series Insert Manual. The Infrared Tube Heater is a positive pressure, single-stage radiant
More informationMin. Mount Height. Min. Mount Height. Length Weight
*! ARNING: This heater must be installed and serviced by trained gas installation and service personnel only! Improper installation, adjustment, alteration, service or maintenance can cause property damage,
More informationInsert Manual. DX3L Series WARNING. For Your Safety
DX3L Series Insert Manual For complete installation instructions, see the Tube Heater General Manual that accompanies this insert manual. The DX3L Series Infrared Tube Heater is a positive pressure, single-stage
More informationInsert Manual. DX3 Series WARNING. For Your Safety
Insert Manual For complete installation instructions, see the Tube Heater General Manual that accompanies this insert manual. The Infrared Tube Heater is a positive pressure, single-stage radiant heater
More informationTypical Mount Height. Combustion Chamber(s)
XTS Series - 4-4 Tube Tube Heater Heater Installation, Installation, Operation, Operation, Maintenance Maintenance and Parts and Manual Parts Manual! ARNIN: This heater must be installed and serviced by
More informationDX2 Series. Models V.6/03
! ARNIN: This heater must be installed and serviced by trained gas installation and service personnel only! Improper installation, adjustment, alteration, service or maintenance can cause property damage,
More informationLD Series Installation Manual
Installation Manual The Infrared Tube Heater is a positive pressure, two stage radiant heater system. This manual provides specific information related to the model. All persons involved with the installation,
More informationLS Series Installation Manual
Installation Manual The Infrared Tube Heater is a positive pressure, single stage radiant heater system. This manual provides specific information related to the model. All persons involved with the installation,
More informationInsert Manual. HL3 Series WARNING. For Your Safety
Insert Manual For complete installation instructions, see the Tube Heater eneral Manual that accompanies this Series Insert Manual. The Infrared Tube Heater is a positive pressure, two-stage radiant heater
More informationLD3 Series Installation Manual
Installation Manual The Infrared Tube Heater is a positive pressure, two stage radiant heater system. This manual provides specific information related to the model. All persons involved with the installation,
More informationDX SERIES TUBE HEATER
DX SERIES TUBE HEATER INSTALLATION, OPERATION, MAINTENANCE AND PARTS MANUAL Detroit Radiant Products Company FOR YOUR SAFETY! IF YOU SMELL GAS: 1. Open windows. 2. Do not touch electrical switches. 3.
More informationAVS Series Installation Manual
Installation Manual The Infrared Tube Heater is a negative pressure, single-stage radiant heater system. This manual provides specific information related to the model. All persons involved with the installation,
More informationLS3 Series Installation Manual
Installation Manual The Infrared Tube Heater is a positive pressure, single stage radiant tube heater system. This manual provides specific information related to the LS3 series models. All persons involved
More informationLine Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas
HVAC Guideline Specifications WHISPER-JET: SET SERIES Two Stage Positive Pressure Gas-Fired Infrared Radiant Tube Type Heater Commercial/Industrial Applications Technical Summary Input Range: 80,000/60,000
More informationInsert Manual. CL Series WARNING. For Your Safety
Insert Manual For complete installation instructions, see the Tube Heater eneral Manual that accompanies this Series Insert Manual. The Infrared Tube Heater is a positive pressure, two-stage radiant heater
More informationInternet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #
INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #238-39387-00 THIS INSTRUCTION SUPPLEMENT IS ONLY INTENDED TO GIVE INSTALLATION INSTRUCTIONS AND INFORMATION RELATED TO THE INDUCED
More informationEngineering Submittal Data PPRTH Patio Radiant Tube Heaters.
12288 Brawn Road 22, Wainfleet, Ontario, Canada L0S 1V0 Phone: 905-899-3473 Fax: 905-899-2262 www.easyradiantworks.com email: erw@vaxxine.com P For either indoor or outdoor installation. Not for use in
More informationCLEARANCES TO COMBUSTIBLES
12288 Brawn Road 22, Wainfleet, Ontario, Canada L0S 1V0 Phone: 905-899-3473 Fax: 905-899-2262 www.easyradiantworks.com email: erw@vaxxine.com Engineering Submittal Data EZB series straight and U shape
More informationSeries RE Infrared Heater
Series RE Infrared Heater Installation, Operation and Service Instructions WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage,
More informationGUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS
GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS SECTION 15540 FUEL- FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS) This section is based
More informationCSD-1 COMMERCIAL BOILER CONTROLS
SUPPLEMENTAL INSTALLATION AND OPERATING INSTRUCTIONS CSD- COMMERCIAL BOILER CONTROLS P/N 400043, Rev. A [/03] CSD- COMMERCIAL BOILER CONTROLS! WARNING Fire, explosion, asphyxiation and electrical shock
More information100T399-SOLA SUPPLEMENT TO INSTALLATION & OPERATION MANUAL INCLUDED WITH WATER HEATER (SERIAL NUMBERS BEGINNING LK AND LATER)
100T399-SOLA SUPPLEMENT TO INSTALLATION & OPERATION MANUAL INCLUDED WITH WATER HEATER (SERIAL NUMBERS BEGINNING LK AND LATER) WARNING If the information in these instructions is not followed exactly, a
More informationTube Heater General Manual
Detroit Radiant Products Co. Tube Heater General Manual To be used in conjunction with Series 2 insert manuals. WARNING Improper installation, adjustment, alteration, service, or maintenance can cause
More informationUSER S INFORMATION MANUAL
USER S INFORMATION MANUAL HOT WATER HEATING BOILERS DOMESTIC WATER HEATERS 150,000-300,000 Btu/hr MODELS EB-EWU-02 IMPORTANT INSTALLER - AFFIX INSTALLATION MANUAL ADJACENT TO THE BOILER CONSUMER - RETAIN
More informationWARNING WARNING. 7D837A thru 7D849A, 7D851A, 7AR79 thru 7AR88. Installation, Operation, Maintenance, and Parts Manual
Installation, Operation, Maintenance, and Parts Manual Please read and save these instructions. This heater must be installed and serviced by trained gas installation and service personnel only! Read carefully
More informationSERIES EvenTube INFRARED HEATER. Installation, Operation and Service Instructions. Model ETS Infrared Patio Heater. Two-Stage
Installation, Operation and Service Instructions INFRARED HEATER SERIES EvenTube Model ETS Infrared Patio Heater Two-Stage WARNING: FOR OUTDOOR USE ONLY WARNING Improper installation, adjustment, alteration,
More informationUSER S INFORMATION MANUAL
USER S INFORMATION MANUAL UPFLOW/HORIZONTAL & DOWNFLOW TWO STAGE INDUCED DRAFT GAS FURNACES Recognize this symbol as an indication of Important Safety Information If the information in this manual is not
More informationPH Series Manual WARNING. Detroit Radiant Products Co. Installation, Operation, Maintenance and Parts. For Your Safety
Detroit Radiant Products Co. PH Series Manual Installation, Operation, Maintenance and Parts All persons involved with the installation, operation and maintenance of the heater system must read and understand
More informationDTHS SERIES TUBE HEATER INSTALLATION, OPERATION MAINTENANCE AND PARTS MANUAL. Detroit Radiant Products Company FOR YOUR SAFETY!
DTHS SERIES TUBE HEATER INSTALLATION, OPERATION MAINTENANCE AND PARTS MANUAL Detroit Radiant Products Company FOR YOUR SAFETY! IF YOU SMELL GAS: 1. Open Windows. 2. Do not touch electrical switches. 3.
More informationSERIES. 10 year limited warranty on Burner Core 5 year limited warranty on All combustion and. 2 year limited warranty on All Burner Controls
TM SERIES Available with 40,000 to 200,000 BTU/Hr. inputs and tube lengths from 10 feet to 70 feet. Aircraft Hangars Auto Dealerships Farm Buildings Fire Stations Body Shops Car Washes Sports Facilities
More informationASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)
ASSEMBLY INSTRUCTIONS - NXS SERIES OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED RADIANT
More informationBGH Series Hot Surface Ignition Control
Installation Instructions BGH Series Issue Date April 14, 2011 BGH Series Hot Surface Ignition Control Application The BASO Gas Products BGH Series Hot Surface Ignition (HSI) control is microprocessor
More informationNational Comfort Products 539 Dunksferry Road Bensalem, PA (215) Fax: (215)
National Comfort Products 539 Dunksferry Road Bensalem, PA 19020 (215) 244-1400 1-800-523-7138 Fax: (215) 639-1674 14299575-10/29/2014 NOTE: These installation and maintenance instructions should be left
More informationOPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS
OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVN/P-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7/CSA 21.4 2000 Gas Fired Construction
More informationSUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!
SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N 238-44219-00 (Replaces pg. 2 in instruction manual.) CONGRATULATIONS! You have just purchased one of the finest water heaters on
More informationEHL Series Installation, Operation, Maintenance and Parts Manual
Installation, Operation, Maintenance and Parts Manual CE Certified 230V-50Hz. [G20(C5), G25(C6), G31(C7)] Infrared Tube Heater. The EHL Series Infrared Tube Heater is a positive pressure, two-stage radiant
More informationService Manual Model 3163
Service Manual Model 3163 Contents Important Safety Information.......... 1 Specifications.................. 2 General Information.............. 2 Direct Vent Requirements........... 2 Propane System................
More informationInstallation, Operation and Service Instructions DU/DUH RANGE DUAL OUTPUT INFRARED HEATERS
Installation, Operation and Service Instructions DU/DUH RANGE DUAL OUTPUT INFRARED HEATERS WARNINGS WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage,
More informationINFRARED RADIANT HEATERS
IRH-1R INFRARED RADIANT HEATERS High and Low Intensity RSU SERIES Unit is shown rotated at a 45 angle. RSD SERIES HIGH INTENSITY INFRARED HEATERS RSD Series Ceramic Heaters Special Honeycomb Tile Design
More informationZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING
See unit nameplate for manufacturer and address. 507258-04 7/2018 Supersedes 10/2017 ZG 036, 048, 060, 072, 074 (3, 4, 5 and 6 Tons) ZG 092, 102, 120, 150 (7-1/2, 8-1/2, 10 and 12 Tons) ROOFTOP UNITS ZG
More informationInstallation Instructions Dual Fuel Ranges
Installation Instructions Dual Fuel Ranges E30DF74EPS E36DF76EPS E48DF76EPS 5995447082 2 Safety IMPORTANT SAFETY INSTRUCTIONS Safety Precautions Do not attempt to install or operate your unit until you
More informationSeries GR/ET Infrared Heater
Series GR/ET Infrared Heater Installation, Operation and Service Instructions WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property
More informationSTS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS
SUBMITTAL DATA (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS PROJECT: ENGINEER: CONTRACTOR: DISTRIBUTOR: SCHWANK MODEL #: FUEL: APPROVED BY: DATE: APPROVAL #: 1 Submittal NOTICE:
More informationInstallation, Operation and Service Instructions RS RANGE RESIDENTIAL INFRARED HEATERS
Installation, Operation and Service Instructions RS RANGE RESIDENTIAL INFRARED HEATERS WARNINGS WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage,
More informationOPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1500T DUAL FUEL CONSTRUCTION HEATER
OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For F-1500T DUAL FUEL CONSTRUCTION HEATER CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7 2000/ CSA 2.14 2000 Gas Fired
More informationQHT Manual for: SU-2A Gas Burner
1 QHT Manual for: SU-2A Gas Burner 50,000 BTU/H to 250,000 BTU/H The burner shall be used only with NATURAL GAS or LP GAS. Warning: If the following instructions are not followed exactly, a fire or explosion
More informationMulti-Function Cooktop
INSTALLATION GUIDE Multi-Function Cooktop Contents Wolf Multi-Function Cooktop.................... 3 Multi-Function Cooktop Specifications............ 4 Multi-Function Cooktop Installation...............
More informationUSER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY...................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS.......................... 2 INTERMITTENT IGNITION DEVICE..........
More informationInstallation Guide. 5 Series VGC and VGSU Built-In Gas Cooktops
Installation Guide 5 Series VGC and VGSU Built-In Gas Cooktops Table of Contents Warnings & Important Safety Instructions 3 Dimensions VGC Cooktops 6 Specifications VGC Cooktops 7 Dimensions VGSU Cooktops
More informationG71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature
Service Literature Corp. 0804 L2 Revised 05 05 2008 G71MPP G71MPP SERIES UNITS G71MPP series units are high efficiency multi position (upflow, downflow, horizontal right and left) gas furnaces equipped
More informationGUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS
GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS SECTION 15540 FUEL- FIRED HEATERS (Alternate - SECTION 235523 - GAS-FIRED RADIANT HEATERS)
More informationG60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature
Service Literature Corp. 0204 L2 Revised 11 2006 G60UH(X) G60UH(X) SERIES UNITS G60UH(X) series units are mid efficiency gas furnaces used for upflow or horizontal applications only, manufactured with
More informationPH Series Manual WARNING. Detroit Radiant Products Co. Installation, Operation, Maintenance and Parts. For Your Safety
Detroit Radiant Products Co. PH Series Manual Installation, Operation, Maintenance and Parts All persons involved with the installation, operation and maintenance of the heater system must read and understand
More informationLNB 1000 Series Low Nox Burner
Installation and Service Instructions ARNIN: If the information in these instructions is not followed exactly, a fi re or explosion may result, causing property damage, personal injury or death. In the
More informationInstallation, Operation, Maintenance and Parts Manual
Installation, Operation, Maintenance and Parts Manual 7DC27 thru 7DC32 Please read and save these instructions. This heater must be installed and serviced by trained gas installation and service personnel
More informationPT Series Manual WARNING. Detroit Radiant Products Co. Installation Operation Maintenance and Parts. For Your Safety
Detroit Radiant Products Co. PT Series Manual Models P-16T & P-32T Installation Operation Maintenance and Parts Important The LP gas heater is designed and approved for use as a construction heater in
More informationA. Product Data: Include rated capacities, furnished specialties and accessories.
BASE BID: SECTION 15542 FUEL-FIRED RADIANT HEATERS PART 1 - GENERAL 1.1 SUMMARY A. Furnish and install a Co-Ray-Vac Low Intensity Vented Infrared Radiant Vacuum Gas Heating System. System must be certified
More informationKG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING
See unit nameplate for manufacturer and address. 507350-03 3/2016 Supersedes 9/2015 KG 024, 030, 036, 048, 060, 072, 074, 090 (2, 2-1/2, 3, 4, 5, 6 and 7-1/2 Tons) KG 092, 102, 120, 150 (7-1/2, 8 1/2,
More informationINTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION
INSTALLATION AND OPERATING INSTRUCTIONS FOR THE HARDY Fuel Oil Furnace Models D-140 & D-350 HARDY MANUFACTURING COMPANY, INC. 12345 ROAD 505 PHILADELPHIA, MS 39350 PHONE: (601) 656-5866 FAX: (601) 656-4559
More informationSERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY
Bousquet Technologies Inc. 2121, Nobel, Ste Julie, Quebec, Canada, J3E1Z9 SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL Oil-Fired air heater for industrial and commercial use. FOR YOUR SAFETY Do not
More informationSynergy WARNING FOR YOUR SAFETY. High Intensity Infrared Heaters. Installation, Service, and Maintenance Manual COMBUSTION RESEARCH CORPORATION
COMBUSTION RESEARCH CORPORATION Synergy High Intensity Infrared Heaters Installation, Service, and Maintenance Manual! WARNING Improper installation, adjustment, alteration, service or maintenance can
More informationGARAGE / WORKSHOP INFRARED HEATERS
GARAGE / WORKSHOP INFRARED HEATERS 22,000-25,000 BTU/HR Heater For: Garages / Workshops Barns / Utility Buildings / Storage Sheds Animal Pens / Stalls Loading Docks Building Construction Sites Doorways
More informationWARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE
TROUBLESHOOTING INTEGRATED FURNACE Failure to read and follow all instructions carefully before installing or operating this control, could cause personal injury and/ or property damage. 50A55 INTEGRATED
More informationQuad Tube Heaters WARNING WARNING. Installation, Operation, Maintenance and Parts Manual
Installation, Operation, Maintenance and Parts Manual Please read and save these instructions. This heater must be installed and serviced by trained gas installation and service personnel only Read carefully
More informationtio-pal PH Series Gas-Fired High Intensity Infra-Red Patio Heater ! WARNING! WARNING! WARNING! WARNING! FOR YOUR SAFETY FOR YOUR SAFETY
Patio-Pal PH Series Patio Heater Installation, Operation, Maintenance and Parts Manual! WARNING: This heater must be installed and serviced by trained gas installation and service personnel only! Improper
More informationKGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING
See unit nameplate for manufacturer and address. 506380 01 11/2009 KGA024, 030, 036, 048, 060, 072 (2, 2 1/2, 3, 4, 5, and 6 Tons) KGA092, 102, 120, 150 (7 1/2, 8-1/2, 10, and 12 Tons) KGA180, 210, 240,
More informationINSTALLATION GUIDE Dual Fuel Ranges
INSTALLATION GUIDE Dual Fuel Ranges Contents Wolf Dual Fuel Ranges......................... 3 Safety Instructions............................ 4 Dual Fuel Range Specifications.................. 5 Dual Fuel
More informationViking Installation Guide
Viking Installation Guide Viking Range Corporation Front Street Greenwood, Mississippi 38930 USA (66) 455-00 For product information, call -888-VIKING (845-464) or visit the Viking Web site at vikingrange.com
More informationResidential Garage Heater Installation, Operation, & Maintenance Instruction Manual (Mount a copy of these instructions adjacent to the heater)
Form RH-IOM-11 210080 Residential Garage Heater Installation, Operation, & Maintenance Instruction Manual (Mount a copy of these instructions adjacent to the heater) MODEL IDENTIFICATION Record the information
More informationREPLACEMENT PARTS LIST
REPLACEMENT PARTS LIST PACKAGED GAS HEATING/ELECTRIC COOLING R7TQ SERIES 6-, 7.5-, AND 10-TON, 81% STEADY STATE EFFICIENCY IMPORTANT This document is primarily intended to assist qualified individuals
More informationDetroit Radiant Products Company DSC Series Manual. Installation, Operation, Maintenance, and Parts ! WARNING ! DANGER
Detroit Radiant Products Company DSC Series Manual Installation, Operation, Maintenance, and Parts Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury,
More informationITH-SERIES GAS-FIRED INFRARED TUBE HEATERS TECHNICAL MANUAL
ITH-SERIES GAS-FIRED INFRARED TUBE HEATERS TECHNICAL MANUAL mwarning: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation,
More informationTUBE HEATER TROUBLESHOOTING GUIDE
TUBE HEATER TROUBLESHOOTING GUIDE MODELS: DTH(S) Series Tube Heaterer THESE HEATERS MUST BE INSTALLED AND SERVICED BY TRAINED GAS INSTALLATION AND SERVICE PERSONNEL ONLY. READ AND UNDERSTAND ALL INSTRUCTIONS
More informationFor use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G
PGM-1 Cooktops For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G Install ation Instructions Part No. 65476 Rev. B Table of Contents Appliance Safety...1 Important Safety Instructions...2
More informationCommercial Water Heater Replacement Parts. Price List. For Models: SBS, SBD, SBN, SDV, SUF, PCE and CSB. Prices Effective
Commercial Water Heater Replacement Parts Price List For Models: SBS, SBD, SBN, SDV, SUF, PCE and CSB Prices Effective October 2, 2006 This parts price catalog supercedes book number SCBPB00306 and all
More informationSLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature
Service Literature Corp. 1029 L7 SLP98UHV SLP98UHV SERIES UNITS SLP98UHV series units are high efficiency upflow, horizontal right and left) gas furnaces equipped with variable capacity gas valve, variable
More informationEHL Series Installation, Operation, Maintenance, and Parts Manual
Installation, Operation, Maintenance, and Parts Manual 230V-50Hz. [G20 (C14), G25 (C15) and G31 (C16)] Infrared Tube Heater. The EHL Series Infrared Tube Heater is a positive pressure, two-stage radiant
More informationINSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure)
INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and understood before installing, operating or servicing this heater. INFRARED
More informationOPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS
OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-200 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003
More informationGAS UNITS KITS AND ACCESSORIES 505,172M 08/06
2006 Lennox Industries Inc. Dallas, Texas, USA GAS UNITS KITS AND ACCESSORIES 505,172M 08/06 Litho U.S.A. IGNITION CONTROL REPLACEMENT KIT INSTALLATION INSTRUCTIONS FOR IGNITION CONTROL CONVERSION KIT
More informationModel UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED
Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters Sizes 30-125 carry an additional approval for use in residential garage/workshops under CSA International Requirement 10.96 - U.S.
More informationLUMINOUS A PATIO HEATER LIKE NO OTHER
LUMINOUS A PATIO HEATER LIKE NO OTHER Manual for Installation, Operation & Maintenance BPL-HAB20 BPL-HAB40 BPL-HAB50 DANGER If you smell gas: 1. Shut off gas to appliance. 2. Extinguish any open flame.
More informationS150 S300 CONSTRUCTION HEATERS. Rev: August 15, 2008 SERVICE AND MAINTENANCE MANUAL No PLEASE RETAIN FOR FUTURE REFERENCE PRODUCTS
S150 & S300 CONSTRUCTION HEATERS Rev: 2.7.2 August 15, 2008 SERVICE AND MAINTENANCE MANUAL No. 934-6637 PLEASE RETAIN FOR FUTURE REFERENCE PRODUCTS A DIVISION OF HAUL-ALL EQUIPMENT LTD. 4115-18 Avenue
More informationInstallation Instructions
50ZPB, C, 50ZHB, C, PA3Z ---A, PH3Z ---A, PA4Z, PH4Z, PAJ4,PHJ4,WJA4,WJH4 SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters 5---20 kw For 14 SEER, R---410A Manufactured Home Installation Instructions
More information100% Safety Shutoff Control 40,000 BTUH Input Rating Constant Pilot Propane Gas
glor sun The Original Outdoor Patio Heater Manufactured by INFRARED DYNAMICS, INC. Yorba Linda, CA 92886 U.S.A. Tel: (714) 572-4050 Fax: (714) 572-6093 Toll-Free: (888) 317-5255 www.infradyne.com SPECIFICATIONS:
More informationParts List for Ener-Radiant XL Tube Heaters
Parts List for Ener-Radiant XL Tube Heaters ERXL-0 F09XL ERXL-0 NG / BRN & Cont Box 0 Front Flange F09XL ERXL-0 LP / BRN & Cont Box 009 Reflector End Cap F00XL Tube Set- 0' 099 Spring Clips 0 Tube H.E.
More informationOWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series
OWNER S MANUAL Manufactured Home Downflow Gas Furnace: MGD-B Series Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com Owner s Manual MGD-B SERIES GAS FURNACE
More informationResidential Garage Heater Installation, Operation, & Maintenance Instruction Manual (Mount a copy of these instructions adjacent to the heater)
Form RH-IOM-15 11222016 Residential Garage Heater Installation, Operation, & Maintenance Instruction Manual (Mount a copy of these instructions adjacent to the heater) MODEL IDENTIFICATION Record the information
More informationUSER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS.......................... 2 INTERMITTENT IGNITION DEVICE...........
More informationP4000 Construction Heater
342 N. Co. Rd. 400 East Valparaiso, IN 46383 219-464-8818 Fax 219-462-7985 www.heatwagon.com Installation and Maintenance Manual Please retain this manual for future reference. P4000 Construction Heater
More informationOPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS
OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVN/P-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7/CSA 21.4 2000 Gas Fired Construction
More informationOPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-400T DUAL FUEL CONSTRUCTION HEATER
OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For F-400T DUAL FUEL CONSTRUCTION HEATER CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7 2000/ CSA 2.14 2000 Gas Fired
More information