1 Alfamini-Alfamax series High efficiency air handling unit for wellness areas Air flow rates from to m 3 /h rev.02 Trattamento dell aria SELECTION MANUAL ISO 9001: Cert.n 0882/4 FAST S.p.A.

2

3 Index English General 4 Energy efficiency 5 Use limits 5 Description of the Alfamini/ Alfamax units 6 Accessories 8 Nominal technical data 9 Operating schemes for Alfamini - Alfamax 10 Control system 11 Simplified method for the unit selection 12 Operating limits 14 Units performance 15 Accessible plate heat exchanger (standard) 20 Hydraulic schemes for the connections 21 Dimensions 22

4 General In the modern wellness centers, swimming pools or SPA, the temperature control and humidity conditions of the environment represent a crucial requirement for the visitors comfort. In particular, the pool area requires a constant balance at any time of year; the continuing variation from dry and wet conditions of the users requires a perpetual and effective monitoring of both air temperature (max. 2-3 C higher than water temperature) and relative humidity. With too high humidity values, breathing is actually inhibited while too low values can worsen the cold feeling as the skin evaporation is accelerated. The particular wellness needs (high temperatures and constant relative humidity control), the need to maintain certain temperatures in the pool reintegrating hygienic requirements for a portion daily (usually at least 5% of the volume of the tank every day), the great demand for hot water for sanitary use, the considerable air flow requirements and the control of sensitive and latent loads to keep as low as possible the thermal differential between input and environment are all aspects that have a strong incentive for the designer to research plant types best suited to reduce energy consumptions. GIVEN THE PECULIARITY OF THE ENVIRONMENTS THAT CAN BE SERVED BY ALFAMINI AND ALFAMAX UNITS, THIS MANUAL IS ONLY INTENDED TO PROVIDE PRODUCT INFORMATION AND INDICATIONS FOR THE CHOICE OF UNITS. SPECIAL REQUIREMENTS NEED A BESPOKE STUDY: IN THIS CASE PLEASE CONTACT THE TECHNICAL -COMMERCIAL FAST DEPARTMENT. To meet the demands of the before described environments FAST SpA offers the AlfaMini (5 sizes with nominal flow rates from to m³/h) and Alfamax units (3 sizes with nominal flow rates from to m³/h). The main unit function, which is a plug and play machine, is to dehumidify while providing control of wellness conditions of the environment. The unit combines a heat pump, a system of sensible and latent heat recovery from humid air expelled from premises and a free heating system of the water pool making it optimized for the reduction of energy consumption. The structure and all internal components are designed for maximum corrosion resistance. Selection manual 4 GB

5 Energy efficiency Facilities where the units of the Alfamini and Alfamax series find appilcation (swimming center, wellness area, etc..) are characterized by a very high energy consumption. The air handling units should therefore be optimized for the least possible impact in the energy balance of the system. The technical solutions adopted by the units are able to reduce the energy consumption through: - Use of efficient energy recovery from the exhaust air. The recovery system consists of a single (for the Alfamini series) or double (for Alfamax) plate cross-flow heat recovery unit; - Use of a heat pump with energy recovery function from the exhaust air and energy integration into the supply air flow. The cooling system operates with refrigerant R410A: the TEWI Index (Total Equivalent Warming Impact), which represents the parameter related to emissions of refrigerant during the life cycle of the units and those due to the CO2 emissions for energy production, is lower than all other types of refrigerant currently available. The circuit is equipped with an electronic expansion valve, which unlike the conventional thermal expansion valve, it allows to optimize the operation of the compressor thereby reducing the electricity consumption. - Use of high efficiency plug-fans equipped with electric motors with efficiency class EFF1. The direct coupling between fan and motor allows for the reducing of losses due to transmission (beltpulley). These power losses can reach up to 20% of the absorbed power of the fan shaft; - Use of inverter devices for the electric motors speed control of the plug fans ; A logic control with automatic handling of operation cycles, so made to reduces the energy consumption. Operating limits The rooms in which the Alfamini and Alfamax units operate distinguish for being particularly aggressive. AIR CHARACTERISTICS : The units are suitable to handle air from swimming pools treated with chlorinebased disinfectants. WATER CHARACTERISTICS : Maximum concentration of chlorine in water: 1.4 mg/l. ANY FURTHER APPLICATION THAT PROVIDES FOR CONCENTRATIONS IN THE AIR OR WATER OF PARTICULAR DISINFECTANTS OR OTHER SPECIAL SUBSTANCES NEEDS A PRELIMINARY EVALUATION BY OUR TECHNICAL-COMMERCIAL OFFICE, AS RESULT GUARANTEE FAILURE. AVOID DIRECT CONTACT BETWEEN UNITS AND PURE DETERGENTS. PROPERLY PROTECT THE PLATE EXCHANGERS OF THE REFRIGERATION CIRCUIT WITH SUITABLE WATER FILTERS TO AVOID CLOGGING. Selection manual 5 GB

6 Alfamini/Alfamax: components location ALFAMINI EXHAUST SUPPLY OUTSIDE ALFAMAX EXHAUST SUPPLY OUTSIDE 7 1 Compressors cabinet separate from air flow 2 Evaporating heat exchange coil 3 Condensing heat exchange coil 4 Water heat exchange coil 5 Recirculation damper 6 Recirculation damper for Alfa cycle 7 3-way valve with modulating actuator 24V 8 Fresh air damper equipped with actuator 9 Exhaust damper equipped with actuator 10 Exhaust fan (no. 2 for Alfamax) 11 Supply fan (no. 2 for Alfamax) 12 G4 plan filters (EN779) 13 F9 soft bags (EN779) 14 Drops separator 15 Cross flow plate heat recovery unit 16 Electrical panel and electronic controller 17 Plate heat exchanger for heat transfer to the swimming pool water Selection manual 6 GB

7 Alfamini ed Alfamax descriptions These units, in the standard executions, are constuìituted by a section which internally raggruppa the supply/exhaust fans and filters, and a further section equipped with refrigerant circuit and from heat recovery units. FRAME The bearing frame is made of aluminium profiles with anodisazion treatment which grants the necessary protection to the corrosion due to the potentially aggressive atmosphere. To facilitate the internal and external cleaning and avoid the dust build-up, the edges are rounded. Profiles are linked each other through nylon corners reinforced with glass fibre. All fixing screws are Marutex brand to grant an exceptional resistance to corrosion. CASING The casing is made of sandwich panels with 50 mm thick fixed to the frame with proper blocking profiles. This fi xing system permits uniform pressure over the casing, providing excellent air and water tightness (according to the EN 1886). Panels are made of internal surface in pre-painted galvanized steel, external surface in pre-painted galvanized steel and insulation by means of injected polyurethane with density 42 kg/m3. The accessible doors use selfclosing handles. Furthermore, all bearing elements and the components closings and are completely painted to guarantee the maximum resistance to corrosion. The inferior surface of the unit is equipped with draining panels in pre-painted galvanized steel with central discharge. Upon request panels can be made in different materials for the sheets and mineral wool (density 40 kg/m3 or 100 kg/m3) as insulator. It is advisable to verify the different options with Fast technical office to check the feasibility. BASEMENT The basement is steady for all sizes and made in galvanised steel sheet. CROSS FLOW STATIC RECOVERY The energy recovery of the exhaust air acts through a single (for the Alfamini series) or double (for the Alfamax series) cross flow plate heat recuperator air/air. The heat recovery units are subjected to a complete paint treatment. DAMPERS In the standard configuration, the unit is equipped with 4 dampers: - a damper placed outside, on the exhaust air flow; - a damper placed outside, on the fresh air flow; - a recirculation damper (used to permit the maximum speed of the room air flow); - a recirculation damper placed before the heat recuperator to make the alfa cycle. All dampers are made of anodized alluminium and each controlled by modulating actuators 24V (with spring return for the external dampers). The accurate construction allows for the reducing of the air laeckage. FAN SECTION Fans sections are epoxy painted resistant to corrosion, equipped with plug fans with wheels with high performance backward-curved blades. Electric motors with effi ciency class EFF1 driven to the wheel, to be controlled by inverter (standard). FILTERS Panel filters are included on the exhaust (efficiency class G4 in compliance with EN779) and panel + bag filters on the supply (efficiency class G4 + F9 in compliance with EN779) which allow to respect the norms currently in force referring to room air quality. A differential flow switch for the clogging filters is supplied on the supply/exhaust as standard. REFRIGERANT CIRCUIT It is equipped with scroll compressor with rubber anti-vibration dampers, exchange coils refrigerant gas/air with copper pipes and painted aluminium fins and frame, filtration devices, electronic expansion valve, liquid receiver, drier fi lter, control (pressure transducers and lights) and protection (high and low pressure switches), connections in brazed copper, ecologic refrigerant R410A. The cooling circuit is inserted in a compartment isolated from the air flow to facilitate the control and maintenance operations. WATER HEATING COIL Coil is completely painted to grant the highest resistance to corrosion. The coil is standard equipped with a 3-way valve with 24V modulating actuators. COMPLETE CONTROL BOARD It is installed inside the unit. Electrical installation for the connections of power and signal, installation pipe with cable-fixing clamp and sleeve accessories, and protection class IP44. Selection manual 7 GB

8 MICROPROCESSOR CONTROL AND REGULATION The unit has a microprocessor control system, able to handle the different operating modes, providing maximum energy efficiency in all conditions. The RS485 interface card is supplied standard (MODBUS protocol) to be used for connection to the supervision systems and remote control. The electronic control, according to the variable opening of the dampers and their combination, acts in the following mode: - Automatic management of the operation mode both for handling and functions; - Dehumidification with external air; - Energy recovery with the help of the cooling system; - Automatic switching of the ALFA cycle (particular cycle in which the cooling system participates in the dehumidification of the air to be treated); - Management of the signal to activate or not the heat exchanger for the pool water heating through a thermostat (not provided); The operating cycles are shown and well-documented in the properly section. HEAT EXCHANGE SYSTEM TO REHEAT THE POOL WATER Heat exchange system to free reheat the swimming pool water composed by a double plate condenser. One of the exchangers is installed in the cooling circuit of the unit inside the machine: the heat exchange takes place between the refrigerant and not aggressive water. The second one is for the swimming pool water, with possibility of inspection, in stainless steel AISI 316L and is supplied loose. The hydraulic circuit between the two plate exchangers has to be completed with the necessary components (pump, water filter, expansion valve, valves, etc.) to installers charge. Accessories PROTECTION ROOF Built as standard in pre-painted sheet. It is a compulsory accessory if the Alfamini / Alfamax unit should be installed outside. REMOTE PANEL The remote panel allows to manage all functions of the unit control system. The remote control panel is supplied without cable connection between it and the board (we recommend using a Belden 3105A). The maximum permitted length of the cable is 50m. For lengths over 50m, please contact the FAST technical sales office. SINGLE HEAT EXCHANGER TO REHEAT THE POOL WATER This is a heat exchanger using refrigerant and water pool. The exchanger is used as a replacement of the double-plate heat exchanger. For further technical information about this exchanger please contact the FAST technical sales. FURTHER ACCESSORIES ARE AVAILABLE UPON REQUEST. Selection manual 8 GB

9 Nominal technical data The technical data described in the following table are referred to a particular operating cycle (cycle with external air dehumidification) and are not representative of all operating conditions which automatically the electronic regulation of the unit is able to adapt to the halls requirements. Alfamini - Alfamax Max. air flow (supply/exhaust) m³/h Static available pressure (supply/exhaust) Pa Recuperators recovered capacity 1 kw 7,9 12,6 20,4 32,0 41,5 59,6 68,6 89,2 Max. recuperators efficiency 1 % 80,8 79,3 80,1 79,5 79,4 93,0 86,0 89,0 Recovered capacity of the refrigerant circuit 1 (heating capacity of the condensing coil) kw 7,5 10,5 21,3 31,7 45,7 46,3 53,6 69,4 Total recovered capacity 1 kw 15,4 23,1 41,6 63,7 87,3 105,9 122,2 158,6 Compressors absorbed capacity 1 kw 1,3 1,6 3,7 6,0 8,4 8,5 9,2 12,8 COP 1-11,8 14,4 11,2 10,6 10,4 12,5 13,3 12,4 Total dehumidification capacity 1 kg/h 15,5 25,2 40,1 63,7 82,7 102,2 127,6 159,5 Shaft power of the supply fan kw 1 x 1,2 1 x 2,1 1 x 3,1 1 x 5,1 1 x 6,5 2 x 4,6 2 x 6,0 2 x 7,8 Shaft power of the exhaust fan kw 1 x 0,9 1 x 1,5 1 x 2,2 1 x 3,8 1 x 4,8 2 x 3,5 2 x 4,2 2 x 5,3 Type / compressors no. n Scroll / 1 Water heating coil (standard) Max. capacity (without active recovery) 1 kw 26,1 35,4 61,6 95,3 124,5 131,9 182,7 205,9 Water flow 2 l/h Pressure drops on water side 2 kpa Plate exchanger R410A / not aggressive water Nominale water flow 3 l/h Pressure drops 3 kpa Accessible plate exchanger with not aggressive water / pool water (standard) Pools nominal water flow 4 l/h Pressure drops on pools side 4, 5 kpa 32,4 34,0 31, ,5 34,2 34,7 34,2 Pressure drops on intermediate circuit side 4 kpa 21,2 22,3 20,3 21,6 22,5 22,3 22,7 22,2 Electrical data * Power supply 400 V - 3 ph - 50 Hz Max. total absorbed current of the supply fan A 3,5 6,2 11,0 14,6 15,0 29, Max. total absorbed current of the exhaust fan A 2,6 4,9 6,4 11,3 11,3 22,0 22,6 30 Max. absorbed current A 11,6 17,1 32,4 49,3 61,3 86,2 99,6 123 Starting current A 32,1 46,1 91,4 181,9 184,3 209,0 223,0 287,0 Dimensions and weights Height mm Width mm Lenght mm Weight kg Note: 1 External air 0 C, R.H. 80%; internal air 29 C, R.H 60%. 2 Water temperature inlet/outlet 70/60 C; pressure drops on water side complete with 3-way valve. 3 Not aggressive water temperature inlet/outlet 27/37 C. 4 Water temperature inlet/outlet of the refrigerant circuit 37/27 C; pools water temperature inlet/outlet 25/35 C. 5 Pressure drops do not include the 3-way valve. * Please refer to the wiring diagram inside the unit. TECHNICAL DATA ARE SUBJECT OF POTENTIAL CHANGES. Selection manual 9 GB

10 Operation schemes Alfamini-Alfamax Here under are the schemes of the main operating modes of the unit (schemes are referred to the Alfamax unit, the operation modes of the Alfamini units are the same as Alfamax units). In the following schemes please consider that the hot water coil is always operating, as it must refer to external air temperatures lower than 10 C with required supply temperature which has to balance the heat loss of the building. Cycle start-up Supply Exhaust From the top 5 External air This operating mode aims at reducing to zero the external air capacity. The total air fl ow is recirculated through the damper n 5 and re-introduced in the swimming pool. The water reheating coil is operating. The operating cycle is activated for the necessary time to reheat the room. Cycle dehumidifying Supply Exhaust Dehumidification with external air From the top External air This operating mode aims at dehumidifying the room with the external air, by balancing the poof rain evaporation. The cooling circuit (composed of compressor n.1 and coils n. 2 and 3) allows to recover the sensible and latent heat of the exhaust air, and transfer it to the inlet air or water by means of the heat exchange system composed of the double exchanger on the water side. The hot water coil n. 4 integrates, if necessary, the heating capacity supplied by the cooling circuit, housed on the inlet air fl ow (condensing coil n.3). Dehumidification with outside air and alpha cycle Supply Exhaust 4 3 From the top External air If convenient, the compressor also contributes to the swimming pool dehumidifying. The fresh air fl ow rate is modulated by the fans inverters to reach the required wellness conditions. According to the external ambience temperature the unit adjusts the operation in order to reach the best energy savings. Dehumidification with outside air (night cycle) Supply Exhaust From the top External air During the night operation the unit adjusts the function settings to adapt to the evaporating variations of the pool and reduce the consumptions at minimum. Selection manual 10 GB

11 Cycle with heat transfer to water If the air temperature conditions in the ambience are satisfi ed, the heat so rejecked by the cooling circuit will be given to the swimming pool water, by means to a double plate exchanger (standard). A plate exchanger is an essential part of the cooling circuit of the unit (exchanger R410A/water of intermediate circuit, in the following fi gure indicated with n. 1). A further inspectionable exchanger (operating with recirculation water of the intermediate circuit/ swimming pool water, in the following fi gure indicated with n. 2) is supplied together with the unit. The heat system thus constituted is of very easy maintenance. The components and the connections among the exchangers are responsibility of the client. 1 2 The scheme is indicative. For simplicity, all the components needed to complete the water circuit are not shown. Control system The control system of Alfamini/ Alfamax units is equipped with a 16-bit microprocessor with flash technology and software specifically designed for the control of all functions. The set information, alarms, timing settings and all parameters are displayed on a multi-function control panel with graphic display inside the cabinet. The control system automatically provides: to implement the cheaper operating cycle and more suited to the room needs; to make the minimum air renewal required by law in force; to manage the initial stages of the heating up system; to implement a reduced function cycle when possible; to switch from air heating operation to water heating operation. For further information please refer to the control specific manual. Remote panel inside the electrical panel (standard). Selection manual 11 GB

12 Simplified method for units selection Table 1 - SPECIFIC EVAPORATION OF THE POOL HALL (g/h for m 2 of water surface) Internal room conditions Hall temper. ( C) Relative humidity (%) Temperature d.b. ( C) g/h for m 2 of water surface Table 2 - POOL USE Pool use Use factor Residential 0,5 Fitness club 0,65 Therapy/Elderly Swim 0,65 Hotel 0,8 Institutional/schools 0,8 Public pools 1,0 SPAs and whirlpools Contact FAST Table 3 - ACTIVITY COEFFICIENT Internal activity g/h each person A- Seated at rest 50 B- Seated very light work 80 C- Seated, light work 110 D- Walking, standing 130 E- Moderate dancing 280 F- Walking briskly with loads 330 G- Light exercise 450 H- Medium atletic activity 500 I- Athletics 560 DEHUMIDIFYING POWER OF THE EXTERNAL AIR (g/h for mc/h of external inlet air flow in the room) g/h taken out a water cqua a sportat for mc/h i of external air inlet 3 / h d ia ri a estern a 20 Internal room conditions: 25 C-50UR% 25 C-60UR% C-70UR% External temperature index g/h taken out a cqua water a sportat for mc/h i of external air inlet d a ri a 3 / h i a 5 0 Internal room conditions: 27 C-50UR% 27 C-60UR% 27 C-70UR% External temperature index Selection manual 12 GB

13 g/h taken out a c qu water a a sportat for mc/h i of external air /h inlet d i a ri a Internal room conditions: 29 C-50UR% 29 C-60UR% 29 C-70UR% External temperature index g/h taken q out u a water a sportat for i mc/h of external air h d iinlet a ri a Internal room conditions: 31 C-50UR% 31 C-60UR% 31 C-70UR% External temperature index g/h taken out c qua water a sportat for imc/h of external air inlet /h d i a ri a Internal room conditions: 33 C-50UR% 33 C-60UR% 33 C-70UR% External temperature index IMPORTANT COMMENT: The Alfamini-Alfamax units, in the execution described in this technical manual, are not able to cool the room, therefore in these diagrams the allowed temperature index is equal or inferior to the internal room temperature. The use of tables and diagrams before described, allow to get the required air flow (and therefore to the Alfamini/Alfamax size) necessary for the room dehumidification function. It is a simplified selection method: for further information please contact our technuical/sales department. It will be introduced now the external index temperature which represent the different temperature/humidity combinations of the external air reported in the following table: EXTERNAL TEMPERAT. INDEX External temp. d.b. ( C) External relative humidity (%) Selection example: 1- Given for example a tank with a surface of 100 m2; 2- Assuming that the water temperature is equal to 27 C; the indoor air conditions are equal to 29 C, 60% RH. With these first data from table 1, we can define that the evaporation is equal to 172 g / hour per square meter of water surface. 3- Supposing that swimming pool is used for residential purposes. The use factor, derivable from table 2, is equal to 0,5. Therefore the total humidity generated from water surface (g/h) is given from (tank surface x specific evaporation x use factor): 100 m 2 x 172 g/h m 2 x 0,5 = g/h 4- Assuming now that inside the hall are 17 people doing light exercise. From table 3 we can define that generated Selection manual 13 GB

14 humidity is equal to 450 g/h each person. Therefore, the total generated humidity (g/h) is given by (number of persons x specific evaporation): 17 persons x 450 g/h person = g/h The total humidity is obtained from the sum of the humidity produced by the evaporation of the water surface with that generated by people: g/h g/h = g/h = 16,25 kg/h 5- Now considering, for example, an outdoor temperature index (which represents the project condition/ operating limit for the Alfamini/Alfamax selected units) equal to 26 (i.e. outside air at a temperature of 26 C with 54% RH) and temperature/ humidity temperature inside the room of 29 C with 60% RH: from graphs we obtain an eliminated humidity value of 4.1 g/h for m/h of fresh air into the hall. 6- The outside air flow required to compensate the evaporation produced by the water surface and people is obtained from the ratio between total humidity and the dehumidifying power of the external air: g/h : 4,1 g/h mc/h = mc/h Therefore from the table of nominal technical data, the selected unit according to the flow appears to be the Alfamini 040 with a nominal air flow of 4,000 cubic meters/h. According to the difference between the external temperature index and the room internal conditions, the size of the selected unit can vary a lot. Considering in the same example above that the external index now is 20 and not 26, from graph we can get the value of humidity removed is 7 g/h for m/h of fresh air into the room. And therefore the external air flow is: g/h : 7 g/h mc/h = mc/h From the table of the nominal technical data the unit to be selected is therefore the Alfamini 025 with nominal air flow di mc/h. Operating limits The external temperature index, per il quale the Alfamini-Alfamax unit has been selected, represents the operating limit (referred to the external conditions) over that the unit is not able to keep the humidity control in the room. Beyond this limit, if the internal vapore production is constant, the relative controlled humidity will deviate towards higher values. Referring to the before example (external temperature index equal to 26), the side graph represents the indicative trend and not binding: - of the external air inlet in the room (continuous line) in relation to the total air derived from the unit; - of the internal room humidity deriving from unit operation (dotted line). External air flow [%] Internal relative humidity [%] Indicative trend of the external air flow Indicative trend of the internal humidity 100 % Portata Nuova Um Rel Locale UR_1-11 Portata Nominale di Temperatura Esterna External temperature index Selection manual 14 GB

15 Unit performances The performances of the unit which can be obtained from the tables are the following: - eliminated room humidity - recuperators performance (efficiency and recovered power) - refrigerant circuit performance (heating capacity of the condensing coil and compressors absorbed power) - performance of the hot water coil (heating capacity, water flow and pressure drops on water side). The heating capacities of the water coils are referred to the refrigerant circuit not operating (max. capacity). Unit performances refer to the conditions reported in the A table. Table A - GENERAL COUNT CONDITIONS OF THE PERFORMANCES Room temperature ( C) Room relative humidity (%) External temperature index External temperature ( C) External relative humidity (%) External air flow compared to the total air flow (%) ALFAMINI 025 PERFORMANCES External temperature index Nominal air flow (mc/h) Eliminated humidity (kg/h) Recuperators efficiency (%) Recovered capacity from recuperator (kw) Heating capacity of the condensing coil (kw) Recovered capacity from compressor (kw) Max. heating capacity of the water coil(kw) Water flow (l/h) Pressure drops on water side (kpa) Max. heating capacity of the water coil (kw) Water flow (l/h) Pressure drops on water side (kpa) Water IN-OUT: C Water IN-OUT: C ,5 80,8 10,2 6,7 1,2 26, ,5 79,4 9,0 7,1 1,3 26, ,5 76,9 7,9 7,5 1,3 26, ,5 74,6 7,0 8,1 1,3 26, ,5 70,8 6,0 8,6 1,3 26, ,5 65,7 4,9 9,2 1,4 26, ,5 61,2 3,9 9,8 1,5 26, ,5 60,6 2, , Selection manual 15 GB

16 ALFAMINI 040 PERFORMANCES External temperature index Nominal air flow (mc/h) Eliminated humidity (kg/h) Recuperators efficiency (%) Recovered capacity from recuperator (kw) Heating capacity of the condensing coil (kw) Recovered capacity from compressor (kw) Max. heating capacity of the water coil(kw) Water flow (l/h) Pressure drops on water side (kpa) Max. heating capacity of the water coil (kw) Water flow (l/h) Pressure drops on water side (kpa) Water IN-OUT: C Water IN-OUT: C ,2 79,3 16,3 9,5 1,6 35, ,2 77,9 14,3 9,9 1,6 35, ,2 75,8 12,6 10,5 1,6 35, ,2 72,8 11,0 11,0 1,6 35, ,2 68,9 9,5 11,6 1,6 35, ,2 63,9 7,8 12,1 1,6 35, ,2 59,6 6,1 12,6 1,6 35, ,6 59,0 3, , ALFAMINI 060 PERFORMANCES External temperature index Nominal air flow (mc/h) Eliminated humidity (kg/h) Recuperators efficiency (%) Recovered capacity from recuperator (kw) Heating capacity of the condensing coil (kw) Recovered capacity from compressor (kw) Max. heating capacity of the water coil(kw) Water flow (l/h) Pressure drops on water side (kpa) Max. heating capacity of the water coil (kw) Water flow (l/h) Pressure drops on water side (kpa) Water IN-OUT: C water IN-OUT: C ,9 80,3 25,5 19,0 3,6 61, ,9 78,6 23,1 20,1 3,7 61, ,9 76,8 20,7 21,4 3,7 61, ,9 73,6 18,2 22,8 3,8 61, ,9 70,2 15,7 24,2 3,8 61, ,9 65,3 12,9 25,8 3,9 61, ,9 60,2 10,0 27,5 4,0 61, ,3 59,2 5, , Selection manual 16 GB

17 ALFAMINI 100 PERFORMANCES External temperature index Nominal air flow (mc/h) Eliminated humidity (kg/h) Recuperators efficiency (%) Recovered capacity from recuperator (kw) Heating capacity of the condensing coil (kw) Recovered capacity from compressor (kw) Max. heating capacity of the water coil(kw) Water flow (l/h) Pressure drops on water side (kpa) Max. heating capacity of the water coil (kw) Water flow (l/h) Pressure drops on water side (kpa) water IN-OUT: C water IN-OUT: C ,7 79,5 41,2 28,3 5,7 95, ,7 77,7 36,1 29,9 5,8 95, ,7 76,0 32,0 31,7 6,0 95, ,7 72,9 27,9 33,6 6,1 95, ,7 69,5 24,1 35,8 6,2 95, ,7 64,6 19,9 38,1 6,3 95, ,7 59,5 15,4 40,5 6,5 95, ,6 58,4 7, , ALFAMINI 130 PERFORMANCES External temperature index Nominal air flow (mc/h) Eliminated humidity (kg/h) Recuperators efficiency (%) Recovered capacity from recuperator (kw) Heating capacity of the condensing coil (kw) Recovered capacity from compressor (kw) Max. heating capacity of the water coil(kw) Water flow (l/h) Pressure drops on water side (kpa) Max. heating capacity of the water coil (kw) Water flow (l/h) Pressure drops on water side (kpa) Water IN-OUT: C water IN-OUT: C ,7 79,4 53,5 41,1 8,2 124, ,7 78,3 47,2 43,2 8,3 124, ,7 76,0 41,5 45,7 8,4 124, ,7 72,8 36,2 48,7 8,6 124, ,7 69,4 31,3 51,7 8,7 124, ,7 64,5 25,8 55,3 8,9 124, ,7 59,4 19,9 59,1 9,2 124, ,3 58,4 10, , Selection manual 17 GB

18 ALFAMAX 160 PERFORMANCES External temperature index Nominal air flow (mc/h) Eliminated humidity (kg/h) Recuperators efficiency (%) Recovered capacity from recuperator (kw) Heating capacity of the condensing coil (kw) Recovered capacity from compressor (kw) Max. heating capacity of the water coil(kw) Water flow (l/h) Pressure drops on water side (kpa) Max. heating capacity of the water coil (kw) Water flow (l/h) Pressure drops on water side (kpa) water IN-OUT: C water IN-OUT: C ,2 92,9 77,3 40,9 8,3 131, ,2 91,0 67,7 43,4 8,4 131, ,2 88,3 59,6 46,3 8,5 131, ,2 84,1 51,7 49,7 8,6 131, ,2 77,6 43,2 53,5 8,7 131, ,2 66,5 32,9 57,6 8,8 131, ,2 63,5 26,3 61,0 9,0 131, ,6 62,6 13, , ALFAMAX 200 PERFORMANCES External temperature index Nominal air flow (mc/h) Eliminated humidity (kg/h) Recuperators efficiency (%) Recovered capacity from recuperator (kw) Heating capacity of the condensing coil (kw) Recovered capacity from compressor (kw) Max. heating capacity of the water coil(kw) Water flow (l/h) Pressure drops on water side (kpa) Max. heating capacity of the water coil (kw) Water flow (l/h) Pressure drops on water side (kpa) water IN-OUT: C water IN-OUT: C ,6 86,1 89,5 47,5 9,1 182, ,6 84,2 78,3 50,3 9,2 182, ,6 81,3 68,6 53,6 9,2 182, ,6 75,9 58,8 57,2 9,3 182, ,6 70,4 49,0 61,1 9,3 182, ,6 60,5 37,3 65,2 9,3 182, ,6 58,8 30,4 68,8 9,5 182, ,3 57,8 15, , Selection manual 18 GB

19 ALFAMAX 250 PERFORMANCES External temperature index Nominal air flow (mc/h) Eliminated humidity (kg/h) Recuperators efficiency (%) Recovered capacity from recuperator (kw) Heating capacity of the condensing coil (kw) Recovered capacity from compressor (kw) Max. heating capacity of the water coil(kw) Water flow (l/h) Pressure drops on water side (kpa) Max. heating capacity of the water coil (kw) Water flow (l/h) Pressure drops on water side (kpa) water IN-OUT: C water IN-OUT: C ,5 89,2 115,9 61,8 12,5 205, ,5 87,4 101,5 65,3 12,7 205, ,5 84,6 89,2 69,4 12,8 205, ,5 79,4 81,1 75,3 12,9 205, ,5 75,1 69,6 77,7 12,9 205, ,5 67,1 54,6 79,1 13,0 205, ,5 61,7 43,0 79,7 13,0 205, ,1 60,4 27, , Selection manual 19 GB

20 Accessible plate exchanger (standard) The accessible plate exchanger is supplied alongside the unit. For the hydraulic connection and for the R410A/water exchanger (inside unit) please refer to the proper paragraph. Technical characteristics: Plate material: Inox steel AISI 316. Plate material for the frame: steel, epoxi paint. Gaskets by nitrile joint. Alfamini 025 Alfamini 040 Alfamini 060 Alfamini 100 Alfamini 130 Alfamax 160 Alfamax 200 Alfamax 250 P (mm) Q (mm) W (mm) weight (kg) Selection manual 20 GB

21 I Hydraulic schemes for connections The following is an example of a connection between the water/r410a exchanger (G in the picture, inside the unit) and the water/accessible water exchanger (A in the picture and supplied loose). The lack or the not proper location of the mentioned components could affect the standard operation of the unit. N O W F A G W W B p C C ALFAMINI ALFAMAX M D E D L Standard components Components and indicative location A Water/accessible water exchanger (supplied loose) G Water/ R410A exchanger (inside Alfamini/Alfamax units) B C Differential flowswitch with digital contact Digital thermostat di consenso for the heat recovery to water I L M Y filter Automatic filling group Filter for pools water D Shut-off valve N Chlorine system E Recirculation pump O Main heat production system F Expansion vessel W Water flow The thermostat (C) is used to detect the water temperature of the intermediate circuit and activate, even when the flow switch (B) gives its consent, the heat transfer to water. The set value of the thermostat is helpful to ensure that the water temperature at the water/r410a exchanger inlet does not exceed 27 C. Below this value, the heat transfer cycle to water is not able to activate. The differential flow switch (B) is used to detect the presence of water flow in the heat exchanger (G). The recirculation pump (E) must work only in case the water flow is present (W). Otherwise it must be off. The heat transfer to the water cycle represents an alternative to the supply air heating. If the set air conditions in the room are satisfied and the consent to the heat transfer to water is not active, the compressor of the refrigerant circuit will turn off. ATTENTION: THE CHLORINE INSTALLATION MUST BE PLACED AFTER THE EXCHANGER (A) Selection manual 21 GB

22 Unit dimensions ALFAMINI ,5 67, , ,5 157, , CONNECTIONS/INSPECTIONS LATO ATTACCHI E SIDE ISPEZIONI , ,5 NB. Dimensions are subject to potentialchanges due to the natural evolution of the product and are therefore not considered as binding. 62, ,5 Selection manual 22 GB

23 ALFAMINI , , ,5 157, , CONNECTIONS/INSPECTIONS LATO ATTACCHI E ISPEZIONI SIDE Quadro elettrico ruotante NB. Dimensions are subject to potentialchanges due to the natural evolution of the product and are therefore not considered as binding , ,5 62, ,5 Selection manual 23 GB

24 ALFAMINI , ,5 57, , CONNECTIONS/INSPECTIONS SIDE LATO ATTACCHI E ISPEZIONI Quadro elettrico ruotante NB. Dimensions are subject to potentialchanges due to the natural evolution of the product and are therefore not considered as binding , ,5 62, ,5 Selection manual 24 GB

25 62,5 356 ALFAMINI , ,5 72, CONNECTIONS/INSPECTIONS LATO ATTACCHI E ISPEZIONI SIDE , ,5 NB. Dimensions are subject to potentialchanges due to the natural evolution of the product and are therefore not considered as binding. 62, ,5 Selection manual 25 GB

26 356 ALFAMINI CONNECTIONS/INSPECTIONS SIDE 54, NB. Dimensions are subject to potentialchanges due to the natural evolution of the product and are therefore not considered as binding Selection manual 26 GB

27 160, ALFAMAX CONNECTIONS/INSPECTIONS SIDE LATO ATTACCHI E ISPEZIONI NB. Dimensions are subject to potentialchanges due to the natural evolution of the product and are therefore not considered as binding. 157,5 157, ,5 62, , Selection manual 27 GB

28 ALFAMAX , ,5 167, , CONNECTIONS/INSPECTIONS SIDE NB. Dimensions are subject to potentialchanges due to the natural evolution of the product and are therefore not considered as binding. 62, , , ,5 Selection manual 28 GB

29 ALFAMAX 250 CONNECTIONS/INSPECTIONS SIDE , , , ,5 NB. Dimensions are subject to potentialchanges due to the natural evolution of the product and are therefore not considered as binding. 62, , , ,5 Selection manual 29 GB

30 NOTE

31

32 Manual printed on recycled paper rev.02 Technical data shown in this booklet are not binding. FAST S.p.A. shall have the right to introduce at any time whatever modifications deemed necessary to the improvement of the product. FAST S.p.A. TRATTAMENTO DELL'ARIA Montagnana (PD) - Italy Via Luppia Alberi, 170 Tel. (+39) Fax info@fastaer.com

Alfamini-Alfamax series

Alfamini-Alfamax series Alfamini-Alfamax series High efficiency air handling unit for wellness areas Air fl ow rates from 4.000 to 25.000 m 3 /h 0612-6180971-rev.01 SELECTION MANUAL 3 FAST S.p.A. Index English General 4 Energy

More information

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65% Dry HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES Calculation of savings (for illustrative purposes) Operating scheme Note: power rates refer to 10,000 m 3 /h of air and

More information

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions Dehumidifiers for radiant cooling systems with heat recovery 50 The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES Dehumidifiers for radiant cooling systems with heat recovery The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1 UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A

More information

FHE. Dehumidifiers for radiant cooling systems with heat recovery. Display. Versions

FHE. Dehumidifiers for radiant cooling systems with heat recovery. Display. Versions FHE Dehumidifiers for radiant cooling systems with heat recovery Display The dehumidifiers with heat recovery of high efficiency series FHE were designed to provide dehumidification and fresh air in a

More information

GHE Dehumidifiers for radiant cooling systems with heat recovery

GHE Dehumidifiers for radiant cooling systems with heat recovery Dehumidifiers for radiant cooling systems with heat recovery The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area

More information

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information

GHE. Dehumidifiers for radiant cooling systems with heat recovery. Display

GHE. Dehumidifiers for radiant cooling systems with heat recovery. Display GHE Dehumidifiers for radiant cooling systems with heat recovery Display The dehumidifiers with heat recovery of high efficiency series GHE were designed to provide dehumidification and fresh air in a

More information

ALFAMINI-ALFAMAX Central Station air handling units high efficiency for wellness areas

ALFAMINI-ALFAMAX Central Station air handling units high efficiency for wellness areas ALFAMINI-ALFAMAX Central Station air handling units high efficiency for wellness areas 1 The plants are quite complex and, therefore, "Fascinating from engineering point of view Conditioning plants are

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are

More information

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories > HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION Available range Unit type IP Reversible heat pump (reversible on the refrigerant side) ECO-FRIENDLY REFRIGERANT GAS Versions (heat recovery) VB Base

More information

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS RAE 1352 F.K + MV AIR R-407C FC Series RAE... F.K Cooling capacity from 77 to 289 kw - 2 circuits The air cooled chillers of RAE... F.K series, are designed for outdoor installation and are particularly

More information

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years

More information

Aquair BCP. Pool air handling units. Electronic Control Optimized energy consumption DESCRIPTION PRINCIPLE SCHEMES RANGE OPERATING LIMITS

Aquair BCP. Pool air handling units. Electronic Control Optimized energy consumption DESCRIPTION PRINCIPLE SCHEMES RANGE OPERATING LIMITS Electronic Control Optimized energy consumption Dehumidifi cation capacity:,7 to 7,7 kg/h Heating and dehumidifi cation of covered pools DESCRIPTION Series are dehumidifi cation units by cooling circuit,

More information

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings 0932EN October 2017 CHARACTERISTIC DATA Air flow rate [m 3 /h] 200 Pressure available (factory configuration) [Pa] 15 Moisture removed (26 C - 65% R.H. - inlet water 15 C) [l/24h] 24,7 Max. absorbed electric

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are

More information

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING

More information

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB Next P 6 112 kw COOLING 5 93 kw HEATING Heat pump air conditioners with upflow air delivery technicalcatalogue T_NXTP_0411_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 4 MODEL IDENTIFICATION...

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw COOLROW Close control air conditioners for In-Row installation Cooling Capacity: 14 61 Available in versions equipped with: - BLDC inverter scroll compressor on board of the unit - Chilled water feeding

More information

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01

More information

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired KLIMAT The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02

More information

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:

More information

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the

More information

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS Indoor motor-driven evaporating units LER 0-0 kw Compact and silent machines with remote dissipation into the air Scroll compressor PLUS R-0A R-0A refrigerant Cooling only Split version Electronic expansion

More information

CRIMSON & CRIMSON MAX

CRIMSON & CRIMSON MAX High efficiency water/water and geothermal heat pumps 5 114 General High efficiency water/water and geothermal heat pumps. Ideal for heating, cooling and production of domestic hotwater with total or partial

More information

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw COMFORT HEAT PUMPS AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw climaveneta.com COMFORT HEAT PUMPS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air to water heat pump for outdoor installation,

More information

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB R407C EASY_R Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans 5,2 41,5 kw T_ESY_R_0508_GB EASY_R R407C INDEX WORKING LIMITS... 3 SERIES IDENTIFICATION... 4 MODEL

More information

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL

More information

ARV.

ARV. ARV www.coldinnovation.it 1 INDEX Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R134a...pag. 5 Semi-hermetic screw compressor...pag.

More information

TECHNICAL INFORMATION DanX Swimming Pool Air Management

TECHNICAL INFORMATION DanX Swimming Pool Air Management TECHNICAL INFORMATION DanX Swimming Pool Air Management Der tages forbehold for trykfejl og ændringer Dantherm can accept no responsibility for possible errors and changes Irrtümer und Änderungen vorbehalten

More information

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT 90% EFFICIENCY HIGHEST EFFICIENCY AIR HANDLING UNIT Packaged energy recovery solutions for Green Buildings Integrated Accumulator, controls and DX Cooling System CLEAN AIR SINCE 1963 Euroclima is a company

More information

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES COOLING CAPACITY FROM 76 TO 612 Kw 1 AND 2 COOLING CIRCUITS RAE 1702 F Kc + P2 28 Above picture is only indicative

More information

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 46 Above picture is only indicative and is not binding AIR FC The packaged air cooled chillers of RAS Kp series are suitable

More information

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw COMFORT CHILLERS AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com COMFORT CHILLERS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air-cooled liquid chiller for outside installation

More information

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with

More information

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools Dehumidification and ventilation for residential, industrial radiant systems and swimming pools HiDew is proud to present a complete range of dehumidifiers for radiant cooling systems and high performance

More information

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS Energy saving thanks to a total recovery p Cooling Heating/DHW h Galletti multi-purpose heat pumps are total recovery units used for a simultaneous hot and

More information

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw Multi-pipe Units with Scroll Compressors Model CMAA Cooling capacity 45-485 kw Heating capacity 50-670 kw CMAA multi-pipe units Simultaneous heating and cooling with one product Standard versions Acoustic

More information

FH - GH FH - GH. Dehumidifiers for radiant cooling systems. Versions

FH - GH FH - GH. Dehumidifiers for radiant cooling systems. Versions Dehumidifiers for radiant cooling systems FH GH 138 The dehumidifiers FH and GH series are high performance units, equipped with robust galvanised steel frame, properly designed to operate in combination

More information

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10 Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW Compressors Scroll Serie: Series: Emissione: Issue: SCAEY Catalogo: Leaflet: Sostituisce: Supersedes: DE 88 04/11 12/10 Index

More information

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB 6 15 kw Next MTR Air conditioners for Metrology Labs with upflow air delivery technicalcatalogue T_NXTMTR_0511_GB INDEX GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3

More information

RMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

RMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL RMA ECO-FRIENDLY REFRIGERANT GAS AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the

More information

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools Dehumidification and ventilation for residential, industrial radiant systems and swimming pools HiDew is proud to present a complete range of dehumidifiers for radiant cooling systems, industrial processes,

More information

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.

More information

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units Premium Efficiency Heat Recovery Unit D-AHU Modular L Air Handling Units About Daikin Our promise is to ensure that customers can depend on Daikin for the ultimate in comfort, so that they are free to

More information

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017 Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air

More information

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Quality Management Systems 0RB 008-05 Nominal cooling capacity 8- The new generation of Aquasnap liquid chillers was designed

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS Total heat recovery multi-purpose units LCP Outdoor monobloc air-water unit LCP - kw Heating, cooling, domestic hot water one single system to meet all kinds of needs. Total heat recovery multi-purpose

More information

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw PROCESS CHILLERS AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com PROCESS CHILLERS MAXIMUM EFFICIENCY IN EVERY TYPE OF PROCESS APPLICATION Air cooled liquid chiller for outdoor

More information

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying INDUSTRIAL DEHUMIDIFIERS Advanced range of compressor and desiccant dehumidifiers Dehumidification and drying To room From room Fan Regeneration heater Dry process air Regeneration air Regeneration area

More information

SA 1 INDEX Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R410A...pag. 5 Scroll compressors...pag. 6 Condenser coils...pag. 6 Brazed

More information

FRAL SRL via dell industria e dell artigianato, 22/C Carmignano di Brenta - PADOVA - ITALY

FRAL SRL via dell industria e dell artigianato, 22/C Carmignano di Brenta - PADOVA - ITALY FRAL SRL via dell industria e dell artigianato, 22/C - 35010 Carmignano di Brenta - PADOVA - ITALY TELPHONE: +39 049 9455839 FAX: +39 049 5991129 E-MAIL: info@fral.it WEB: www.fral.it DEHUMIDIFIERS FD

More information

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw Air cooled chillers with brushless oil-free compressors R-134a RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw External installation with very low sound level Cooling circuit with

More information

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating. capacity: Heating capacity: 20,8 to 135,1 kw 22,6 to 144,7 kw Scroll compressors R-410A refrigerant Confi guration fl exibility Silent operation DESCRIPTION The AirDuo cooling units and are units which

More information

Pool dehumidification. Airpool+

Pool dehumidification. Airpool+ Pool dehumidification Airpool+ Airpool + The new high performance Airpool+ dehumidifier is used for the dehumidification of indoor pools. Thanks to its design, in which the cooling circuit s components

More information

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98 Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw Scroll Compressors Series: SCAEY-FC Leaflet: DE 98 Issue: 01/16 Supersedes: 12/13 Identification code Index Index... pag. 2 Identification code...»

More information

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning : Direct expansion close control air conditioners with up-flow or down-flow air delivery. Cooling Capacity: 7 102 NEW SOFTWARE R410A rcgroupairconditioning E C A C UP FLOW DOWN FLOW MAIN FEATURES Precision

More information

H4T R410A. refrigerant

H4T R410A. refrigerant H4T INDEX Polyvalent unit working modes...pag. 4 Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R410A...pag. 5 Scroll compressors...pag.

More information

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center Uniflair LE TDER-TUER Energy-saving units with backward-curved fans 20-100kW > Perimeter cooling for medium/large data center > Refrigerant R-410A Available Versions: > Downflow (TDER) > Upflow (TUER)

More information

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS EN DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS EBH EDS EBH EDS HIGH PRESSURE UNITS EBH high pressure ducted units and EDS Double Skin units, thanks to their high pressure fan decks, permit to satisfy

More information

Double Skin Casing Air Handling Units

Double Skin Casing Air Handling Units Double Skin Casing Air Handling Units Double wall with 25 mm insulation Modular design for clean process application flexibility all the requirements 2,000 40,000 CFM AUTUMN Air Handling Units incorporate

More information

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98 Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw Scroll Compressors Series: SCAEY-FC Leaflet: DE 98 Issue: 04/11 Supersedes: 12/10 Identification code Index Index... pag. 2 Identification code...»

More information

Construction details: Structure and base in hot dip galvanised sheet steel with epoxy pain finish (RAL 9002)

Construction details: Structure and base in hot dip galvanised sheet steel with epoxy pain finish (RAL 9002) Water cooled internal chiller and heat pump units with scroll compressors Cooling capacity from 106 kw to 385 kw NXW Heating capacity from 119 kw to 419 kw R410A Aermec participates in the EUROVENTProgram:

More information

PRODUCT RANGE HEAT PUMPS 2012

PRODUCT RANGE HEAT PUMPS 2012 PRODUCT RANGE HEAT PUMPS 2012 TABLE OF CONTENTS Product range...4 Heat pump system benefits...6 Is the heat pump considered as a "RENEWABLE SOURCE"?...8 ENERGETIC advantage of the heat pump...10 ECONOMIC

More information

Neosys Product catalogue

Neosys Product catalogue 00/0 Neosys Product catalogue Providing indoor climate comfort NEOSYS 00 0 kw Air cooled chiller/heat pump YEAR WARRANTY* Quality makes the difference* Introduction to the range NEOSYS is providing chilled

More information

LSN Series. Air cooled water chillers, heat pumps and motocondensing units with axial fans Capacities from 4 to 40 kw.

LSN Series. Air cooled water chillers, heat pumps and motocondensing units with axial fans Capacities from 4 to 40 kw. LSN Series Air cooled water chillers, heat pumps and motocondensing units with axial fans Capacities from 4 to 40 kw. Trattamento dell aria 0208-6180705-rev.0 SELECTION, INSTALLATION AND MAINTENANCE MANUAL

More information

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps. Air/water cooled chillers and heat pumps 41 303 kw General BETA ECHOS is a range of chillers and ductable air-water heat pumps. Configurations HP: Reversible heat pump LE: For connection to remote evaporator

More information

Blue Box Epsilon Echos +

Blue Box Epsilon Echos + Blue Box Epsilon Echos + 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Packaged version in 5 sizes Nominal cooling capacity (A35;W7): 6 26 kw Nominal heating

More information

KELVIN Clim F497. Kelvin air conditioning

KELVIN Clim F497. Kelvin air conditioning KELVIN Clim F497 Cooling Capacity: 400 ~ 1260 kw Free-Cooling Capacity: 497 ~ 1492 kw Packaged air cooled liquid chillers with free-cooling system in A class energy efficiency for outdoor installation,

More information

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating

More information

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired AHU The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake

More information

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors -15 C +63 C E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems or

More information

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line) ERAH MC Ka AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line) Range 394-1220 kw Liquid chillers air condensing unit Package external installation Screw compressors

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units

york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units YORK YPRE RTR/RTP SERIES Air to air packaged rooftop units Cooling

More information

LDN Series. Trattamento dell aria SELECTION, INSTALLATION AND MAINTENANCE MANUAL

LDN Series. Trattamento dell aria SELECTION, INSTALLATION AND MAINTENANCE MANUAL LDN Series Air cooled water chillers and heat pumps with axial fans Capacities from 37 to 480 kw. Trattamento dell aria 0208-6180711-rev.0 SELECTION, INSTALLATION AND MAINTENANCE MANUAL GB FAST S.p.A.

More information

HIWARM kw. Air-water system with external and internal BLDC unit. Total heat recovery multi-purpose units HIWARM PLUS

HIWARM kw. Air-water system with external and internal BLDC unit. Total heat recovery multi-purpose units HIWARM PLUS Total heat recovery multi-purpose units HIWARM Air-water system with external and internal BLDC unit HIWARM - kw The perfect combination between multi-purpose, inverter technology and style Multi-purpose

More information

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION CI/SfB 56.83 X DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION Introduction Nordair Niche is one of the UK's leading specialists in

More information

Motor-driven condensing units MTE MTE R-410A

Motor-driven condensing units MTE MTE R-410A Motor-driven condensing units MTE Outdoor motor-driven condensing units MTE - 0 kw Efficiency and compactness for commercial air conditioning Scroll compressor PLUS R-0A R-0A refrigerant Cooling only Split

More information

ARS. 1

ARS.   1 ARS www.rigelimpianti.it 1 INDEX Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R410A...pag. 5 Scroll compressors...pag. 6 Brazed plates

More information

FH - GH Dehumidifiers for radiant cooling systems

FH - GH Dehumidifiers for radiant cooling systems Dehumidifiers for radiant cooling systems FH GH The dehumidifiers FH and GH series are high performance units, equipped with robust galvanised steel frame, properly designed to operate in combination with

More information

1

1 ST www.coldinnovation.it 1 INDEX Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R410A...pag. 5 Scroll compressors...pag. 6 Condenser

More information

COMPACT AIR HANDLING UNIT

COMPACT AIR HANDLING UNIT COMFORT AIR HANDLING UNITS COMPACT AIR HANDLING UNIT climaveneta.com COMFORT AIR HANDLING UNITS AIR TREATMENT ENHANCING QUALITY OF LIFE. Compact air handling unit for indoor and outdoor installation. Air

More information

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

Geolo THE GROUND SOURCE HEAT PUMP PLUSES Geolo THE GROUND SOURCE HEAT PUMP PLUSES RENEWABLE TECHNOLOGIES Geolo is able to exploit the Energy present in the water and underground thanks to the geothermal exchangers. Soil and water absorb the solar

More information

MPI DC 8-29 kw. Outdoor monobloc unit with BLDC compressor. Air chillers and heat pumps MPI DC PLUS

MPI DC 8-29 kw. Outdoor monobloc unit with BLDC compressor. Air chillers and heat pumps MPI DC PLUS Air chillers and heat pumps MPI DC Outdoor monobloc unit with BLDC compressor MPI DC - 9 kw Large operating range and energy efficiency under every condition BLDC scroll compressor PLUS BLDC rotary compressor

More information

VERSO Air Handling Units

VERSO Air Handling Units Energy efficient solutions for profitable indoor climate VERSO-S air supply units VERSO-R air handling units equipped with regeneration system VERSO-P air handling units equipped with recuperation system

More information

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired AHU The ultimate in air handling units: directly and indirectly fired Mark has developed a range of air handling units with several options for a wide variety of applications. From a simple air intake

More information

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES LS ir cooled water chillers with axial fans + LS The LS water chiller range has been designed for small and medium residential and commercial applications. They are suitable for generating chilled water

More information

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Большая библиотека технической документации   каталоги, инструкции, сервисные мануалы, схемы. Большая библиотека технической документации http://splitoff.ru/tehn-doc.html каталоги, инструкции, сервисные мануалы, схемы. AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive,

More information

Easdale International INFINITY

Easdale International INFINITY Easdale International INFINITY Air flow from 800 to 0.000 m 3 /h APPLIED SYSTEM AIR HANDLING UNITS AHU N : 0.0.502 Range: Easdale International www.eurovent-certification.com www.certiflash.com Engineered

More information

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB 4,5 22,5 kw Air-conditioned server-racks for direct installation into the room technicalcatalogue T_CLSEVO_0113_GB INDEX HIGHLIGHTS... 3 PLANT TYPE... 3 GENERAL CHARACTERISTICS... 5 SERIES IDENTIFICATION...

More information

LZA High efficiency air to water heat pumps with HP compressor

LZA High efficiency air to water heat pumps with HP compressor High efficiency air to water heat pumps with HP compressor -10 C +43 C +60 C HP C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information