Installation Instructions

Size: px
Start display at page:

Download "Installation Instructions"

Transcription

1 Installation Instructions Blower Packages For Gas Furnaces KCBBA00TG KCBBA00TG NOTE: Read the entire instruction manual before starting the installation. INTRODUCTION When upgrading a Coleman, Intertherm, or Miller gas furnace for use with an outdoor heat pump or air conditioner, the blower motor assembly must always be changed out. Two kits cover this change out conversion. Kit KCBBA00TG covers the conversion of Coleman 00B, 00C, 00/D, /D, C, DGRT and DLRS series, Intertherm MGHA, and Miller MMHA in -/-, -, -/-, and -ton gas furnaces. Kit KCBBA00TG covers the conversion of Coleman 00B, 00C, 00/D, /D, C, DGRT and DLRS series, Intertherm MGHA, and Miller MMHA in gas furnaces above tons. SAFETY CONSIDERATIONS Installing and servicing heating equipment can be hazardous due to gas and electrical components. Only trained and qualified personnel should install, repair, or service heating equipment. Untrained personnel can perform basic maintenance functions such as cleaning and replacing air filters. All other operations must be performed by trained service personnel. When working on heating equipment, observe precautions in the literature, tags, and labels attached to or shipped with the unit and other safety precautions that may apply. Follow all safety codes. In the United States, follow all safety codes including the National Fuel Gas Code NFPA No. -/ANSI Z.-. In Canada, refer to the current edition of the National Standard of Canada CAN/CGA- B.- and.-m Natural Gas and Propane Gas Installation Codes. Wear safety glasses and work gloves. Have fire extinguisher available during start-up, adjustment, and service call procedures. Recognize safety information. This is the safety-alert symbol alert to the potential for personal injury.. When you see this symbol on the furnace and in instructions or manuals, be Understand the signal word DANGER, WARNING, or CAUTION. These words are used with the safety-alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies a hazard that could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage. WARNING: Before installing or servicing system, always turn off main power to system. There may be more than disconnect switch. Turn off accessory heater power if applicable. Electrical shock can cause personal injury or death. DESCRIPTION AND USAGE Kits KCABBA00TG and KCABB00TG are comprehensive kits containing a blower motor assembly, control box assembly, adapter frame, and a parts bag. Installation of components is determined by unit of application. The installation instruction is composed of sections covering specific units and sizes.. Section covers the installation of KCBBA00TG into Coleman 00B, 00C, 00/D, /D, C, DGRT and DLRS series -/-, -, -/-, and -ton gas furnaces.. Section covers the installation of KCBBA00TG into Coleman 00B, 00C, 00/D, /D, C, DGRT and DLRS series gas furnaces above tons.. Section covers the conversion of -/-, -, -/-, and -ton Intertherm MGHA and Miller MMHA Series Gas Furnaces using kit KCBBA00TG and the conversion of units above -ton using kit KCBBA00TG. INSTALLATION SECTION This section covers the installation of KCBBA00TG into Coleman 00B, 00C, 00/D, /D, C, DGRT and DLRS series -/-, -, -/-, and -ton gas furnaces. REMOVE BLOWER FROM CARN. Remove blower from carton. Unit is heavy so exercise care when handling.. Straighten any flanges bent during shipment.. Remove cardboard packing from blower wheel. Form: AG-CBBA-0 Cancels: AG-CABA-0, AG-CAWH-0 Printed in U.S.A. 0- Catalog No. -CB-BA

2 . Check rotation of blower wheel in housing. If any rubbing occurs between blower wheel and housing, adjust blower wheel on motor shaft by loosening blower wheel setscrew and sliding wheel along shaft until rubbing stops.. Check blower wheel setscrew for tightness. When tightening setscrew, be sure screw is on flat side of motor shaft.. Check control box and wiring harnesses for shipping damage. File claim with shipper if shipment is damaged or incomplete. REMOVE EXISTING BLOWER FROM FURNACE. Turn electrical power at main electrical service entrance to OFF position.. Remove furnace door.. Unplug motor connector plug from receptacle on furnace control box by pinching clasping tabs on sides of plug and pulling plug straight up from receptacle.. Remove blower mounting screws, then remove blower from front of furnace. Retain screws for new blower installation. INSTALL KCBBA00TG BLOWER ASSEMBLY AND CONTROL BOX A. Mount Control Box and Adapter Frame to Blower. Remove cover from blower control box by removing screw. Retain screw for reinstallation.. Mount control box cover on blower wrapper using No. 0 X /-in. screws. (See Fig..). Install adapter frame to blower housing using No. 0 X /-in. screws. (See Fig..). Mount control box to cover on blower with screw removed in Step above. (See Fig..) Make sure bottom of cover engages inside of control box flange. B. Install Blower Into Unit. Start blower rail flanges into blower slots and push blower into furnace until mounting bracket flange is against furnace. (See Fig..). Secure blower with screws removed earlier in Procedure, Step. Attach blower ground lead under screw in blower compartment that contacts an unpainted surface. C. Connect Wiring Harnesses. Connect -pin plug of -in. wiring harness (supplied) to blower control box receptacle. (See Fig..). Connect -pin plug of -in. harness to furnace control box receptacle. (See Fig..). Connect -pin receptacle of -in. harness to -pin plug of -in. wiring harness. (See Fig..). Connect -pin plug of blower wiring harness to blower control box receptacle. (See Fig..) A. 00B Series Furnace MODIFY FURNACE CONTROL BOX WIRING. Remove /-in. knockout on furnace control box.. Remove furnace control box cover.. Run loose red wire (supplied) from R of low-voltage terminal board on blower control box through knockout hole in furnace control box. (See Fig. and.). Run loose blue wire from -pin receptacle of -in. wiring harness through knockout hole in furnace control box.. Install strain relief to wires and snap into knockout hole of furnace control box.. Remove gray wires from low-voltage connection of transformer. Cut terminals off and strip wires / in. Twist ends of gray wires and red wire together and secure with wire nut provided. (See Fig..). Remove yellow wires from low-voltage connection of transformer. Cut terminals off and strip wires / in. Twist ends of yellow wires and blue wire (of -pin receptacle through knockout) together and secure with wire nut provided. (See Fig..). Replace furnace control box cover. B. 00C, C, 00/D, /D, DLRS, and DGRT Series Furnace. Remove /-in. knockout on furnace control box.. Remove furnace control box cover.. Run loose blue wire from -pin receptacle of -in. wiring harness through knockout hole in furnace control box. (See Fig. and Fig.,,, or.). Install strain relief to wire and snap into knockout hole of furnace control box.. For 00C, C, 00/D, and /D remove yellow wires from low-voltage connection of transformer. Cut terminals off and strip wires / in. Twist ends of yellow wires and blue wire (or -pin receptacle through knockout) together and secure with wire nut provided. (See Fig.,, or.)

3 BLOWER ASSY CONTROL BOX COVER ADAPTER FRAME Fig. Blower Assembly A CONTROL BOX ASSY BLOWER ASSY ADAPTER FRAME Fig. Blower Assembly Installation A

4 . For DLRS and DGRT series furnaces, remove of the low-voltage connections of transformer. A gray and a yellow wire should be removed leaving the third yellow wire connected to the transformer. That is the yellow wire that goes to the reignitor module. Cut terminals off and strip the wires / in. Twist ends of yellow, gray and blue wire (or -pin receptacle through knockout) together and secure with wire nut provided. (See Fig..). Replace furnace control box cover. CONNECT THERMOSTAT A. Heating Only Thermostat ( wire). Connect thermostat wires W to W of low-voltage terminal board on blower control box.. Series variation a. For 00B Series: connect thermostat R terminal to loose red wire from -pin plug of -in. harness. (See Fig..) b. For 00C, C, 00/D, /D, DLRS, and DGRT Series: tape loose end of red wire from -pin plug of -in. harness, and connect thermostat wire R to R on low-voltage terminal board. (See Fig..). Remove locking clip on HEAT/COOL switch on blower control box. (See Fig. or.). Explain to homeowner that HEAT/COOL switch must be manually set in appropriate position for heating or cooling.. Turn ON-OFF switch on furnace junction box to ON position. B. Heat/Cool Thermostat ( wire). Connect thermostat wires W and Y to W and Y, respectively, of low-voltage terminal board on blower control box.. Series variation a. For 00B Series: connect thermostat R terminal to loose red wire from -pin plug of -in. harness. (See Fig..) b. For 00C, C, 00/D, /D, DLRS, and DGRT Series: tape loose end of red wire from -pin plug of -in. harness, and connect thermostat wire R to R on low-voltage terminal board. (See Fig..) NOTE: Do not remove locking clip from HEAT/COOL switch.. Turn ON-OFF switch on furnace junction box to ON position. C. Heat/Cool Thermostat ( wire). Remove external jumper wire from G and Y of low-voltage terminal board on blower control box.. Connect thermostat wires W, Y, and G to W, Y, and G, respectively, of low-voltage terminal board on blower control box.. Series variation a. For 00B Series: connect thermostat R terminal to loose red wire from -pin plug of -in. harness. (See Fig..) b. For 00C, C, 00/D, /D, DLRS, and DGRT Series: tape loose end of red wire from -pin plug of -in. harness, and connect thermostat wire R to R on low-voltage terminal board. (See Fig..) NOTE: Do not remove locking clip from HEAT/COOL switch.. Turn ON-OFF switch on furnace junction box to ON position. CONNECT CONDENSING UNIT Connect condensing unit control relay or contactor to Y and C on blower low-voltage terminal board on blower control box. COMPLETE UNIT INFORMATION PLATE Using ballpoint pen, complete information requested on information plate. Peel backing off plate and affix in upper right-hand corner of vestibule panel. COMPLETE UNIT INSTALLATION. For -wire thermostats only: Remember to explain to homeowner that HEAT/COOL switch must be manually set to appropriate position.. Replace furnace door.. Restore power to unit.. Cycle furnace in both heating and cooling modes to ensure proper operation. SERVICE A qualified service person should clean and lubricate the blower unit each heating and cooling season. Clean the blower unit when cooling coil is cleaned. Lubricate motor every years if motor is used intermittently, or every years if motor is in continuous operation. Remove motor to lubricate. Place approximately drops of SAE 0 non-detergent oil in oil port. Plug port securely. Check electrical connections for tightness and controls for proper operation each heating and cooling season. Service as necessary.

5 LOCKING CLIP HEAT/COOL BLOWER CONTROL BOX -IN. WIRING HARNESS -IN. WIRING HARNESS PIN PIN RWGYC LOW VOLTAGE TERMINAL BOARD PIN / GND BLOWER ASSY E PIN EXISTING CONTROL BOX STRAIN RELIEF R OF THERMOSTAT Fig. Coleman 00B Wiring Layout A INSTALLATION SECTION This section covers the installation of KCBBA00TG into Coleman 00B, 00C, 00/D, /D, C, DGRT and DLRS series gas furnaces above tons. REMOVE BLOWER FROM CARN. Remove blower from carton. Unit is heavy so exercise care when handling.. Straighten any flanges bent during shipment.. Remove cardboard packing from blower wheel.. Check rotation of blower wheel in housing. If any rubbing occurs between wheel and housing, adjust blower wheel on motor shaft by loosening blower wheel setscrew and sliding wheel along shaft until rubbing stops.. Check blower wheel setscrew for tightness. When tightening setscrew, be sure screw is on the flat side of motor shaft.. Check control box and wiring harnesses for shipping damage. File claim with shipper if shipment is damaged or incomplete. REMOVE EXISTING BLOWER FROM FURNACE. Turn electrical power at main electrical service entrance to OFF position.. Remove furnace door.. Unplug motor connector plug from receptacle on furnace wiring box by pinching clasping tabs on sides of plug and pulling plug straight up from receptacle.. Remove blower mounting screws, then remove blower from front of furnace. Retain screws for new blower installation. A. Install Blower Into Unit INSTALL KCBBA00TG BLOWER ASSEMBLY AND CONNECT WIRING. Start blower rail flanges into blower slots and push blower into furnace until mounting bracket flange is against furnace. (See Fig..). Secure blower with screws removed earlier in Procedure, Step. Attach blower ground lead under screw in blower compartment that contacts an unpainted surface. B. Connect Wiring Harnesses. Connect -pin plug of -in. wiring harness, supplied in kit, to blower control box receptacle. (See Fig..). Connect -pin plug of -in. harness to furnace control box receptacle. (See Fig..). Connect -pin receptacle of -in. harness to -pin plug of -in. wiring harness. (See Fig..)

6 LOCKING CLIP HEAT/COOL BLOWER CONTROL BOX -IN. WIRING HARNESS -IN. WIRING HARNESS PIN PIN RWGYC LOW VOLTAGE TERMINAL BOARD PIN / GND BLOWER ASSY E PIN EXISTING CONTROL BOX STRAIN RELIEF ELECTRICAL TAPE Fig. Coleman 00C, C, /D, DLRS, and DGRT Wiring Layout A. Connect -pin plug of blower wiring harness to blower control box receptacle. (See Fig..) A. 00B Series Furnace MODIFY FURNACE CONTROL BOX WIRING. Remove /-in. knockout on furnace control box.. Remove furnace control box cover.. Run loose red wire (supplied) from R of low-voltage terminal board on blower control box through knockout hole in furnace control box. (See Fig. and.). Run loose blue wire from -pin receptacle of -in. wiring harness through knockout hole in furnace control box.. Install strain relief to wires and snap into knockout hole of furnace control box.. Remove gray wires from low-voltage connection of transformer. Cut terminals off and strip wires / in. Twist ends of gray wires and red wire together and secure with wire nut provided. (See Fig. and.). Remove yellow wires from low-voltage connection of transformer. Cut terminals off and strip wires / in. Twist ends of yellow wires and blue wire (of -pin receptacle through knockout) together and secure with wire nut provided. (See Fig..). Replace furnace control box cover. B. 00C, C, 00/D, /D, DLRS, and DGRT Series Furnace. Remove /-in. knockout on furnace control box.. Remove furnace control box cover.. Run loose blue wire from -pin receptacle of -in. wiring harness through knockout hole in furnace control box. (See Fig. and Fig.,,, or.). Install strain relief to wire and snap into knockout hole of furnace control box.. For 00C, C, 00/D, and /D remove yellow wires from low-voltage connection of transformer. Cut terminals off and strip wires / in. Twist ends of yellow wires and blue wire (or -pin receptacle through knockout) together and secure with wire nut provided. (See Fig.,, or.)

7 () ON FURNACE CONTROL BOX (L) GRAY GRAY SWICH MANUAL RESET GRAY BLOWER CONTROL (MARKED VAC) FROM BLOWER CONTROL BOX LVTB MARKED R PIN PIN POWER CORD (L) LOAD V LINE 0V LINE 0V LOAD V FROM PIN INCH WIRING HARNESS GAS VALVE (TR) BLOWER CONTROL (COMMON) 00B SERIES. For DLRS and DGRT series furnaces, remove of the low-voltage connections of transformer. A gray and a yellow wire should be removed leaving the third yellow wire connected to the transformer. That is the yellow wire that goes to the reignitor module. Cut terminals off and strip the wires / in. Twist ends of yellow, gray and blue wire (or -pin receptacle through knockout) together and secure with wire nut provided. (See Fig..). Replace furnace control box cover. CONNECT THERMOSTAT A. Heating Only Thermostat ( wire). Connect thermostat wires W to W of the low-voltage terminal board on blower control box.. Series Variation a. For 00B Series: connect thermostat R terminal to loose red wire from -pin plug of -in. harness. (See Fig..) b. For 00C, C, 00/D, /D, DLRS, and DGRT Series: tape loose end of red wire from -pin plug of -in. harness, and connect thermostat wire R to R on low-voltage terminal board. (See Fig..). Remove locking clip on HEAT/COOL switch on blower control box. (See Fig. or.). Explain to homeowner that HEAT/COOL switch must be manually set in appropriate position for heating or cooling.. Turn ON-OFF switch on furnace junction box to ON position. B. Heat/Cool Thermostat ( wire). Connect thermostat wires W and Y to W and Y, respectively, of low-voltage terminal board on blower control box.. Series Variation a. For 00B Series: connect thermostat R terminal to loose red wire from -pin plug of -in. harness. (See Fig..) b. For 00C, C, 00/D, /D, DLRS, and DGRT Series: tape loose end of red wire from -pin plug of -in. harness, and connect thermostat wire R to R on low-voltage terminal board. (See Fig..) NOTE: Do not remove locking clip from HEAT/COOL switch.. Turn ON-OFF switch on furnace junction box to ON position. C. Heat/Cool Thermostat ( wire). Remove external jumper wire from G and Y of low-voltage terminal board on blower control box.. Connect thermostat wires W, Y, and G to W, Y, and G, respectively, of low-voltage terminal board in blower control box.. Series Variation Fig. Coleman 00B Wiring From Transformer A

8 () ON FURNACE CONTROL BOX (L) PIN PIN PIN LOAD V LINE 0V LINE 0V LOAD V POWER CORD (L) FROM PIN INCH WIRING HARNESS GAS VALVE (TR) DAMPER MOR 00C SERIES DIRECT SPARK IGNITION Fig. Coleman 00C Direct Spark Ignition Wiring From Transformer A a. For 00B Series: connect thermostat R terminal to loose red wire from -pin plug of -in. harness. (See Fig..) b. For 00C, C, 00/D, /D, DLRS, and DGRT Series: tape loose end of red wire from -pin plug of -in. harness, and connect thermostat wire R to R on low-voltage terminal board. (See Fig..) NOTE: Do not remove locking clip from HEAT/COOL switch.. Turn ON-OFF switch on furnace junction box to ON position. CONNECT CONDENSING UNIT Connect condensing unit control relay or contactor to Y and C on blower low-voltage terminal board on blower control box. COMPLETE UNIT INFORMATION PLATE Using ballpoint pen, complete information requested on information plate. Peel backing off plate and affix in upper right-hand corner of vestibule panel. COMPLETE UNIT INSTALLATION. For -wire thermostats only: Remember to explain to homeowner that HEAT/COOL switch must be manually set to appropriate position.. Replace furnace door.. Restore power to unit.. Cycle furnace in both heating and cooling modes to ensure proper operation. SERVICE A qualified service person should clean and lubricate the blower unit every heating and cooling season. Clean cooling coil when blower unit is cleaned. Lubricate motor every years if motor is used intermittently, or every years if motor is in continuous operation. Remove motor to lubricate. Place approximately drops of SAE 0 non-detergent oil in oil port. Plug port securely. Check electrical connections for tightness and controls for proper operation each heating and cooling season. Service as necessary.

9 () ON FURNACE CONTROL BOX (L) PIN PIN PIN LOAD V LINE 0V LINE 0V LOAD V POWER CORD (L) GRAY FROM PIN INCH WIRING HARNESS SWICH DAMPER MOR DLRS AND DGRT STANDING PILOT WITH REIGNIR Fig. Coleman DLRS and DGRT Standing Pilot Wiring From Transformer A INSTALLATION SECTION This section covers the conversion of -/-, -, -/-, and -ton Intertherm MGHA and Miller MMHA Series Gas Furnaces using kit KCBBA00TG and the conversion of units above -ton using kit KCBBA00TG. REMOVE BLOWER FROM CARN. Remove blower from carton of kit KCBBA00TG or KCBBA00TG. Unit is heavy so exercise care when handling.. Straighten any flanges bent during shipment.. Remove cardboard packing from blower wheel.. Check rotation of blower wheel in housing. If any rubbing occurs between blower wheel and housing, adjust blower wheel position on motor shaft by loosing blower wheel setscrew and adjusting along shaft until rubbing stops.. Check blower wheel setscrew for tightness. When tightening setscrew, be sure screw is on the flat side of motor shaft.. Check control box for shipping damage. File claim with shipper if shipment is damaged or incomplete. NOTE: Use adapter frame and wiring harness supplied. REMOVE EXISTING BLOWER FROM FURNACE. Turn electrical power at main electrical service entrance to OFF position.. Remove furnace door.. Unplug motor connecter plug from receptacle on furnace control box by pinching clasping tabs on sides of plug and pulling plug straight up from receptacle.. Remove blower mounting screws then remove blower from front of furnace. Retain screws for new blower installation. INSTALL KCBBA00TG OR KCBBA00TG BLOWER ASSEMBLY AND CONTROL BOX A. Mount Control Box and Adapter Frame to Blower. Remove cover from blower control box by removing screw. Retain screw for reinstallation.. Mount control box cover on blower wrapper using No. 0 X /-in. screws. (See Fig..)

10 () ON FURNACE CONTROL BOX (L) PIN PIN PIN LOAD V LINE 0V LINE 0V LOAD V POWER CORD (L) FROM PIN INCH WIRING HARNESS SWICH /D SERIES STANDING PILOT Fig. Coleman /D Standing Pilot Wiring From Transformer A. Mount control box to cover on blower with screw removed in Step. (See Fig..) Make sure bottom of cover engages inside of control box flange.. Install adapter frame to blower housing using No. 0 X /-in. screws supplied in kit KCBBA00TG or KCBBA00TG. (See Fig..) B. Install Blower into Unit. Start blower rail flanges into blower slots and push blower into furnace until mounting bracket flange is against furnace. (See Fig..). Secure blower with screws removed earlier in Procedure, Step. Attach blower ground lead under screw in blower compartment that contacts an unpainted surface. C. Connect Wiring Harnesses. Connect -pin plug of - to -pin wiring harness to blower control box. (See Fig..). Connect -pin plug of - to -pin wiring harness to furnace control box receptacle. (See Fig..). Connect -pin plug of blower wiring harnesses to blower control box. (See Fig..) MODIFY FURNACE CONTROL BOX WIRING. Remove furnace control box cover.. Remove red wire from low-voltage connection of transformer and cut off terminal.. Clip brown wire from low-voltage side of transformer. (See Fig..). Strip / in. of brown and red wires.. Twist end of brown and red wires together and secure with wire nut provided. (See Fig..). Remove black wire from high-voltage side of transformer and cut off terminal.. Locate black wire at fan switch that goes to -pin receptacle of furnace control box and clip at fan switch.. Strip ends / in. each of black wire just removed and black wire removed in Step.. Twist ends of black wires together and secure with a wire nut provided. (See Fig..) 0

11 () ON FURNACE CONTROL BOX (L) PIN PIN PIN LOAD V LINE 0V LINE 0V LOAD V POWER CORD (L) FROM PIN INCH WIRING HARNESS BOOSTER () DAMPER MOR C SERIES STANDING PILOT Fig. Coleman C Standing Pilot Wiring From Transformer A 0. Tape exposed ends of black and brown clipped wires with electrical tape.. Connect red and white wires of -in. wiring harness to red and white wires of furnace control box, respectively.. Replace furnace control box cover. CONNECT THERMOSTAT A. Heating Only Thermostat ( Wire). Connect thermostat wire R and W to R and W, respectively, of low-voltage terminal board on blower control box.. Remove locking clip on HEAT/COOL switch of blower control box. (See Fig..). Explain to homeowner that HEAT/COOL switch must be manually set in appropriate position for heating or cooling.. Turn ON-OFF switch on furnace junction box to ON position. B. Heat/Cool Thermostat ( Wire). Connect thermostat wires R, W, and Y to R, W and Y, respectively, of low-voltage terminal board on blower control box. NOTE: Do not remove locking clip from HEAT/COOL switch.. Turn ON-OFF switch on furnace junction box to ON position. C. Heat/Cool Thermostat ( Wire). Remove external jumper wire from G and Y of low-voltage terminal board on blower control box.. Connect thermostat wires R, W, Y, and G to R, W, Y, and G, respectively, of low-voltage terminal board on blower control box. NOTE: Do not remove locking clip from HEAT/COOL switch.. Turn ON-OFF switch on furnace junction box to ON position. CONNECT CONDENSING UNIT Connect condensing unit control relay or contactor to Y and C of blower low-voltage terminal board on blower control box. COMPLETE UNIT INFORMATION PLATE Using a ballpoint pen, complete information requested on information plate. Peel backing off plate and affix in upper right-hand corner of vestibule panel.

12 NOTE: If any of the wire supplied with the furnace must be replaced, it must be replaced with type 0 C min. thermoplastic or it's equivalent. 00B 0 Fig. 0 Coleman 00B Wiring Diagram BR BLOWER 0V TRAN REVERSING RR A R W G Y C ORN ELECTRICAL TAPE CAP FM ALS GROUND SCREW LOAD LINE V SEC 0V PRI V BLOWER CONTROL BLOWER ORN WIRE NUT BRN LIN V TRANS ORN QV COM

13 00C DIRECT SPARK IGNITION 0 NOTE: If any of the wire supplied with the furnace must be replaced, it must be replaced with type 0 C min. thermoplastic or it's equivalent. Fig. Coleman 00C Direct Spark Ignition Wiring Diagram BR BLOWER 0V TRAN REVERSING RR A R W G Y C ELECTRICAL TAPE FAN CAP FM ALS WIRE NUTS BOOST CONDENSATE COIL BOOSTER MOR DAMPER MOR 0V TRAN V GROUND VALVE GROUND BRN POWER GAS CONTROL ON LE V

14 TRANS. 00C STANDING PILOT 0 NOTE: If any of the wire supplied with the furnace must be replaced, it must be replaced with type 0 C min. thermoplastic or it's equivalent. Fig. Coleman 00C Standing Pilot Wiring Diagram BR BLOWER 0V TRAN REVERSING RR A0 R W G Y C ELECTRICAL TAPE FAN ORN CAP FM ALS WIRE NUT LINE 0V PRI V SEC DAMPER MOR GROUND SCREW GAS CONTROL LOAD V

15 TRANS. DLRS AND DGRT STANDING PILOT WITH IGNIR 0 BR BLOWER REVERSING 0V TRAN NOTE: If any of the wire supplied with the furnace must be replaced, it must be replaced with type 0 C min. thermoplastic or it's equivalent. Fig. Coleman DLRS and DGRT Standing Pilot with Ignitor Wiring Diagram A R W G Y C CAP FM ALS ORN WIRE NUT ELECTRICAL TAPE LINE 0V PRI V SEC LOAD FAN DAMPER MOR V PILOT BURNER ELECTRODE GROUND SCREW REIGNIR MODULE GAS CONTROL RR V NOTE: Remove jumper across the G and Y terminals for a -wire thermostat.

16 TRANS. /D STANDING PILOT 0 NOTE: If any of the wire supplied with the furnace must be replaced, it must be replaced with type 0 C min. thermoplastic or it's equivalent. Fig. Coleman /D Standing Pilot Wiring Diagram BR BLOWER 0V TRAN REVERSING RR A R W G Y C ELECTRICAL TAPE FAN ORN CAP FM ALS WIRE NUT LINE 0V PRI V SEC GROUND SCREW GAS CONTROL LOAD V

17 00/D HOT SURFACE IGNITION Fig. Coleman 00/D Hot Surface Ignition Wiring Diagram A0 NEUTRAL 0V PRI V SEC 0 LINE LOAD NOTE: If any of the wire supplied with the furnace must be replaced, it must be replaced with type 0 C min. thermoplastic or it's equivalent. BR BLOWER 0V TRAN REVERSING RR R W G Y C ELECTRICAL TAPE CAP FAN MANUAL RESET FM ALS BOOST CENTRIFUGAL BOOSTER MOR DAMPER MOR V TH TR GROUND SCREW IGNITION MODULE L S OR IGN S OR IGN L WV OR TR WV OR VALVE TH HOT SURFACE IGNIR BRN BRN GRD SCREW BRN GAS CONTROL NOTE: Incoming power must be polarized. Observe color cooling.

18 TRANS. STANDING PILOT 0 NOTE: If any of the wire supplied with the furnace must be replaced, it must be replaced with type 0 C min. thermoplastic or it's equivalent. Fig. Coleman C Standing Pilot Wiring Diagram BR BLOWER 0V TRAN REVERSING RR A R W G Y C ELECTRICAL TAPE FAN CAP FM ORN ALS WIRE NUT LINE 0V PRI V SEC DAMPER MOR GROUND SCREW GAS CONTROL LOAD CONDENSATE COIL BOOSTER MOR BOOST V

19 HEAT/COOL BLOWER CONTROL BOX BLOWER ASSY PIN RWGYC PIN LOW VOLTAGE TERMINAL BOARD LOCKING CLIP AU/FAN/ON PIN EXISTING FURNACE CONTROL BOX Fig. Intertherm MGHA and Miller MMHA Wiring Layout A PIN NEUTRAL FAN ON/OFF L GROUND SCREW WHITE FAN AUX TAPE WHITE PIN TAPE BRN TRANS BRN EXISTING FURNACE CONTROL BOX BRN GAS VALVE Fig. Furnace Control Box Modification A0 COMPLETE UNIT INSTALLATION. For -wire thermostat, position HEAT/COOL switch to appropriate mode. Explain to homeowner that HEAT/COOL switch must be manually set to appropriate position.. For - or -wire thermostats, locking clip should not be removed from HEAT/COOL switch since modes are automatically selected.. Replace furnace door.. Restore power to unit.. Cycle furnace in both heating and cooling modes to ensure proper operation. SERVICE A qualified service person should perform cleaning and lubricating of the blower unit each heating and cooling season. Clean cooling coil when blower unit is cleaned. Lubricate motor every years if motor is used intermittently, or every years if motor is in continuous operation. Remove motor to lubricate. Place approximately drops of SAE 0 non-detergent oil in oil port. Plug port securely. Check electrical connections for tightness and controls for proper operation each heating and cooling season. Service as necessary.

20 INTERTHERM MGHA AND MILLER MMHA SERIES GAS FURNACES 0 BR 0V TRAN Fig. Wiring Diagram A R W G Y C NEUTRAL L CAP FM SLS WHITE WHITE TAPE TAPE BRN GROUND SCREW FS LS BRN GAS VALVE BRN EXISTING FURNACE CONTROL BOX LS FS SLS FM FAN SECONDARY FAN MOR CAP TRAN BR RR FAN ON/OFF SLS CAPACIR TRANSFORMER BLOWER REVERSING BR RR RR V NOTES:. Incoming power must be polarized. Observe color coding. (See furnace data label for electrical data.). If any of the original wire, as supplied, must be replaced, use 0 C thermoplastic type wire or it's equivalent

21 EXISTING FURNACE CONTROL BOX INTERTHEM MGHA AND MILLER MMHA 0 Fig. 0 Intertherm/Miller Wiring Diagram BR BLOWER 0V TRAN REVERSING RR A R W G Y C CAP FM ORN ALS V TRANS TRANS TRANS TRANS EXISTING EXISTING TRANS TRANS TRANSFORMER TRANS EXISTING FAN FAN/ON/OFF

22 RESCO P.O. Box, Indianapolis, IN 0 0c Book/Tab: /d /d Catalog No. -CB-BA

Installation Instructions

Installation Instructions Installation Instructions Manufactured Housing Blower Package for Electric Furnaces KMABA----TE KMABA----TE NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS

More information

Installation Instructions

Installation Instructions Installation Instructions Electric Heater Packages With DC Relay KFCEH NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SINGLE-CIRCUIT

More information

Installation Instructions Part No , Part No Part No

Installation Instructions Part No , Part No Part No Torsion-Flex Motor mount for PSC motors and Rigid-Mount for ECM motors Replacement Kit Cancels: New Installation Instructions Part No. 327752-401, Part No. 327753-401 Part No. 327754-401 IIK-310A-45-11

More information

Installation Instructions

Installation Instructions Electric Heater Packages Installation Instructions TE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing and servicing of heating and air conditioning

More information

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can

More information

Installation Instructions

Installation Instructions Electric Heater Packages Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing and servicing of heating and air conditioning

More information

Installation Instructions

Installation Instructions Installation Instructions Electric Heater Packages KFAEH TE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SINGLE-CIRCUIT GROUND

More information

Installation and Operating Instructions

Installation and Operating Instructions Installation and Operating Instructions Furnace Control Tester KGACT0201 Table 1 Kit Contents DESCRIPTION PART NO. QUANTITY Furnace Control Tester KGACT0201 1 Adapter Harness 320742-301 1 Installation

More information

Installation Instructions

Installation Instructions Installation Instructions Electric Heater Packages KFAEH -CIRCUIT GROUND LUG TERMINAL BLOCK MULTI-CIRCUIT GROUND LUG COOLING CONTROL PLATE ADAPTER PLATE (MUST BE REMOVED WHEN INSTALLING LARGE HEATER) BLOCK

More information

Installation Instructions

Installation Instructions 50ZPB, C, 50ZHB, C, PA3Z ---A, PH3Z ---A, PA4Z, PH4Z, PAJ4,PHJ4,WJA4,WJH4 SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters 5---20 kw For 14 SEER, R---410A Manufactured Home Installation Instructions

More information

Installation Instructions

Installation Instructions Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A Manufactured Home Installation Instructions NOTE: The Dual Point Kit can only be installed on

More information

Installation Instructions

Installation Instructions 50ES---A, 50EZ---A, 50VL---A, 50VG---A, 50VR---A, 50VT---A, 604D--- ---A, 607C--- ---A, 607E,--- ---A, 704D--- ---A, 707C--- ---A, 707E--- ---A PA3G --- --- A, PH3G --- --- A SMALL PACKAGED PRODUCTS Electric

More information

Installation Instructions

Installation Instructions 50ES--A, 50EZ--A, 50VG--A, B, 50VL--A, B, 50VR--A, 50VT--A, B 604D-- --A, 607C-- --A, B, 607E-- --A, 704D-- --A, 707C-- --A, B, 707E-- --A PA3G -- -- A, PH3G -- -- A, PA4G, PH4G PAD3, PHD3, PAD4, PHD4,

More information

Installation Instructions

Installation Instructions Primary Cell Inlet Panel Kit Installation Instructions Part No. 320720-751, -753, -754, -755, -756, -757,-758, and -760 NOTE: Read the entire instruction manual before starting the installation. This symbol

More information

Installation Instructions

Installation Instructions HUMBBSFP1016 HUMCCSFP1016 Small Fan Powered Humidifier and Humidistat Installation Instructions! WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death.

More information

Installation Instructions

Installation Instructions ---751,---754,---755,---756 Condensing Heat Exchanger Kit Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation,

More information

Installation Instructions Part No

Installation Instructions Part No Heat Exchanger Cell Kit Cancels: New Installation Instructions Part No. 326600-751 IIK-310A-45-6 6-02 NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing

More information

Installation Instructions

Installation Instructions Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A, Z Chassis Installation Instructions NOTE: Read the entire instruction manual before starting

More information

Installation Instruction

Installation Instruction KGADC0101BVC INTERNAL VENT KIT Installation Instruction NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service,

More information

Installation Instructions

Installation Instructions Installation Instructions EHMA SERIES ELECTRIC HEATERS FOR PAM3 SERIES PACKAGE AIR CONDITIONERS PHM3 SERIES PACKAGE HEAT PUMPS TABLE OF CONTENTS SAFE INSTALLATION REQUIREMENTS... 2 GENERAL INFORMATION...

More information

Installation Instructions

Installation Instructions Coupling Box Kit Cancels: IIK 340M-40-79 IIK 340M-40-88 9-05 Installation Instructions Part No. 320721-765, 330539-751, -752, -753, -754, -755, -756, and -757 NOTE: Read the entire instruction manual before

More information

Installation Instructions

Installation Instructions Electric Heater Kit For use with GC Geothermal Heat Pumps KWCEH0101B05 KWCEH0101B10 KWCEH0101B15 KWCEH0101B20 Installation Instructions NOTE: Read the entire instruction manual before starting the installation.

More information

Installation Instructions

Installation Instructions EHNA Electric Heaters 5-20kW For 60 Hz Small Packaged Products MODELS: PAD3, PHD3, PAD4, PHD4, PAD5, PHD5, WPA3, WPH3 Installation Instructions NOTE: Read the entire instruction manual before starting

More information

Installation Instructions

Installation Instructions Heat Exchanger Cell Replacement Kit Cancels: IIK 373-35-12 IIK 373L-35-14 12-15-93 Installation Instructions Part No. 310203-752 NOTE: Read the entire instruction manual before starting the installation.

More information

Installation Instructions

Installation Instructions Electric Heaters 5 --- 20 kw Installation Instructions SMALL PACKAGED PRODUCTS 2to5Tons Accessory Electric Heaters (Single---Point Connection) NOTE: Read the entire instruction manual before starting the

More information

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can

More information

Installation Instructions

Installation Instructions CAELHEAT001A00 - CAELHEAT039A00 AAHC05AHAA - AAHC70ESAA PACKAGED AIR---HANDLING UNITS ELECTRIC HEAT ACCESSORY 6 to 30 TONS (21 to 105 kw) 50/60 Hz Installation Instructions TABLE OF CONTENTS SAFETY CONSIDERATIONS...

More information

Installation Instructions

Installation Instructions CRHEATER270A00 - ELECTRIC HEATER ACCESSORY SINGLE PACKAGE ROOFTOP UNITS 15 to 27.5 TONS Installation Instructions TABLE OF CONTENTS SAFETY CONSIDERATIONS... 1 GENERAL... 1 MODEL/CAPACITY TABLES... 2-11

More information

Owner s Information Manual

Owner s Information Manual 48ES---A and 48VL---A Comfort and Performance 13 and 14 SEER Single Packaged Air Conditioner and Gas Furnace System With Puron (R---410A) Refrigerant Single and Three Phase 2---5 Nominal Tons (Sizes 24---60)

More information

Installation Instructions

Installation Instructions Installation Instructions Vent/Exhaust Pipe External Trap Kit KGAET0101ETK Table 1 Kit Contents PART DESCRIPTION PART NO. QUANTITY Condensate Trap 308589-402 1 Tee-Vent Fitting (2-in. PVC) 321496-301 1

More information

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT

installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT installation and start-up instructions HUMIDIFIERS AND HUMIDISTAT HUM Cancels: II 912D-56-3 II HUM-56-1 7-98 MODEL HUMBBLFP1025-A-- FAN-POWERED HUMIDIFIER MODEL HUMBBLBP2018-A-- BYPASS HUMIDIFIER MODEL

More information

INSTALLATION INSTRUCTIONS ELECTRIC HEAT ACCESSORY

INSTALLATION INSTRUCTIONS ELECTRIC HEAT ACCESSORY INSTALLATION INSTRUCTIONS ELECTRIC HEAT ACCESSORY EHK05AKN/B, EHK07AKN/B, EHK10AKN/B, EHK15AKF/B, EHK20AKF/B, EHK15AHN, EHK18AHN, EHK09AKCN, EHK25AHCF, EHK30AHCF Safety Labeling and Signal Words DANGER,

More information

Fig. 1 - Unit PGD4, PGS4, WPG4

Fig. 1 - Unit PGD4, PGS4, WPG4 OWNER S MANUAL 14 SEER Single -Package Air Conditioner and Gas Furnace System with R -410A Refrigerant Single Phase 2 to 5 Nominal Tons Three Phase 3 to 5 Nominal Tons PGD4andPGS4SeriesE,WPG4SeriesB Fig.

More information

Electric Heat Accessory Installation Instructions

Electric Heat Accessory Installation Instructions Electric Heat Accessory Installation Instructions EBP, EBX, EBV, EBW FVM, FEM, FSM, FSU WARNING Electrical shock hazard. Installation or repairs made by unqualified persons can result in hazards to you

More information

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS

WARNING: ELECTRICAL GROUNDING INSTRUCTIONS BK AND BKT BLOWER ACCESSORY INSTALLATION INSTRUCTIONS Model BK Manually led Blower Model BKT Thermostatically led Blower WARNING: ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped with a three-prong

More information

BK AND BKT BLOWER ACCESSORY INSTALLATION INSTRUCTIONS

BK AND BKT BLOWER ACCESSORY INSTALLATION INSTRUCTIONS BK AND BKT BLOWER ACCESSORY INSTALLATION INSTRUCTIONS MODEL BK MANUALLY CONTROLLED BLOWER MODEL BKT THERMOSTATICALLY CONTROLLED BLOWER WARNING: ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped

More information

KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems. Owner's Manual

KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems. Owner's Manual KSACN0101AAA Wired Remote Controller (with Timer Function) For Ductless Systems Owner's Manual TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 3 WIRED CONTROLLER FEATURES AND FUNCTIONS... 5 WIRED CONTROLLER

More information

Installation Instructions

Installation Instructions NAHB00501WK Twinning Kit for HSI Single-Stage Condensing and Non-Condensing Gas Furnaces Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS

More information

Installation Instructions

Installation Instructions 53DS --- 900 --- --- --- 092 Duct---Free Systems Accessory Power Ventilation Kit for In --- Ceiling Cassette Fan Coil Units Size 018 --- 036 Installation Instructions NOTE: Read and become familiar with

More information

Installation Instructions

Installation Instructions Condensing Heat Exchanger Kit Cancels: IIK 8A-- IIK 8A--7 -- Installation Instructions Part No. 171-7 through -7 NOTE: Read the entire instruction before starting the installation. INTRODUCTION This instruction

More information

Installation Instructions

Installation Instructions Heat Exchanger Cell Replacement Kit Cancels: IIK 373L-35-14 IIK 373L-35-17 3-97 Installation Instructions Part No. 310203-752 NOTE: Read the entire instruction manual before starting the installation.

More information

Installation Instructions

Installation Instructions Electric Heater Kit For use with GB, GP and GT eries Geothermal Heat Pumps KWAEH0101N05 KWAEH0101N10 KWAEH0101F15 KWAEH0101F20 Installation Instructions NOTE: Read the entire instruction manual before

More information

Installation Instructions

Installation Instructions EZXCAB Sizes 016 and 020 High Efficiency Air Filtration System Installation Instructions JAN High Efficiency Air Filtration System Fig. 1 - EZXCAB C04001 NOTE: Read the entire instruction manual before

More information

INSTALLATION INSTRUCTIONS Low Ambient Kit NASA201LA, NASA401LA

INSTALLATION INSTRUCTIONS Low Ambient Kit NASA201LA, NASA401LA INSTALLATION INSTRUTIONS Low Ambient Kit NASA201LA, NASA401LA These instructions must be read and understood completely before attempting installation. DANGER, WARNING, AUTION, and NOTE The signal words

More information

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA

INSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA TXV Coils for Manufactured Housing EMA NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance,

More information

Installation Instructions

Installation Instructions Installation Instructions Twinning Kit for HSI Single-and -Stage Upflow Condensing and Non-Condensing Gas Furnaces KGATW060HSI NOTE: Read the entire instruction manual before starting the installation.

More information

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS KSAIF KSAIF0501AAA & KSAIF0601AAA Wi-Fi Interface Kit for Ductless Systems INSTALLATION INSTRUCTIONS NOTE: Read and become familiar with these instructions before beginning installation. TABLE OF CONTENTS

More information

Installation Instruction

Installation Instruction Installation Instruction Upflow Downflow Heating Cooling CC5A Uncased Coil CD5A Cased Coil SUPPLY RETURN EVAPORATOR COIL DOWNFLOW UPFLOW SUPPLY Fig. 1 Typical Installation of CD5A Cased Coil A96244 NOTE:

More information

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

IMPORTANT INSTRUCTIONS - OPERATING MANUAL IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: AK80LSL, AK100LSL Exhaust Fan READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.

More information

Installation Instructions

Installation Instructions Evaporator Coil A Coil --- Cased Multipoise NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...

More information

Installation Instructions Dual Fuel Ranges

Installation Instructions Dual Fuel Ranges Installation Instructions Dual Fuel Ranges E30DF74EPS E36DF76EPS E48DF76EPS 5995447082 2 Safety IMPORTANT SAFETY INSTRUCTIONS Safety Precautions Do not attempt to install or operate your unit until you

More information

Installation Instructions

Installation Instructions 8GXM / 0GXM Multi---Split High---Wall Duct Free Split System 8GXM --- Size 18k, k, and 0k 0GXM --- Size 9k, 1k, and 18k Installation Instructions NOTE: Read the entire instruction manual before starting

More information

OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE 58CLA OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. WELCOME TO A NEW GENERATION

More information

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS RV Products Division INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330C755 CONTROL BOX KIT (12 VDC HEAT READY) 8530-750 CONTROL BOX KIT

More information

Installation Instructions

Installation Instructions KSALA0201R22 KSALA0301410 Low--Ambient Pressure Switch Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY ONSIDERATIONS Improper installation, adjustment,

More information

TABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation.

TABLE OF CONTENTS INTRODUCTION. NOTE: Read the entire instruction manual before starting the installation. Installation NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION... 2 Inspect Equipment... 2 Select

More information

Installation Instructions

Installation Instructions CNPVP CNRVP Cased N Coils Upflow --- Downflow Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

More information

Installation Instructions

Installation Instructions PART NUMBER: 001A00 002A00 SMALL PACKAGED PRODUCTS 1---1/2 TO 5 TONS (50/60 HZ) MOTORMASTER II HEAD PRESSURE CONTROLLER Installation Instructions NOTE: Read the entire instruction manual before starting

More information

Owner s Information Manual

Owner s Information Manual 50EZ---A and 50VT ---A Comfort and Performance 13 and 14 SEER Single Packaged Heat Pump System With PuronR (R ---410A) Refrigerant Single and Three Phase 2---5 Nominal Tons (Sizes 24---60) Owner s Information

More information

Installation Instructions

Installation Instructions Installation Instructions For Cased Coils Upflow-Downflow Heating-Cooling CK5A CK5B SUPPLY RETURN EVAPORATOR COIL DOWNFLOW UPFLOW SUPPLY Fig. 1 Typical Coil Installation NOTE: Read the entire instruction

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl125rok Item Stock Number(s): BFL125ROK IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL,

More information

Installation Instructions

Installation Instructions HC2 HC3 HOT WATER COILS MULTIPOISE Installation Instructions NOTE: Read the entire installation instructions before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration,

More information

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE DR-180 Through the Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT

More information

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE TROUBLESHOOTING INTEGRATED FURNACE Failure to read and follow all instructions carefully before installing or operating this control, could cause personal injury and/ or property damage. 50A55 INTEGRATED

More information

Installation Instructions

Installation Instructions Installation Instructions For Cased and Uncased Coils Upflow-Downflow Heating-Cooling CK5A, CK5B Cased CJ5A Uncased SUPPLY RETURN EVAPORATOR COIL DOWNFLOW UPFLOW SUPPLY Fig. 1 Typical Coil Installation

More information

Installation Instructions

Installation Instructions Installation Instructions Fan Coil Units FG3A NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SAFETY CONSIDERATIONS Improper

More information

Rotary XL (558 Series) and Classic (548 Series)

Rotary XL (558 Series) and Classic (548 Series) INSTALLATION and OPERATING INSTRUCTIONS ROOF MOUNT AIR CONDITIONER Rotary XL (558 Series) and Classic (548 Series) QUICK START SHUR START MODELS MODELS 54812.041 54812.042 55812.041 55812.042 54815.041

More information

Installation Instructions

Installation Instructions CNPVP CNRVP Cased N Coils Upflow --- Downflow Heating --- Cooling Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...

More information

Fig. 1 - Unit PHD4 and WPH4

Fig. 1 - Unit PHD4 and WPH4 OWNER S MANUAL 14 SEER Single -Package Heat Pump System with R -410A Refrigerant Single Phase and Three Phase 2 to 5 Nominal Tons PHD4 Series F and WPH4 Series B Fig. 1 - Unit PHD4 and WPH4 A09034 NOTE

More information

Commercial Water Heater Replacement Parts. Price List. For Models: SBS, SBD, SBN, SDV, SUF, PCE and CSB. Prices Effective

Commercial Water Heater Replacement Parts. Price List. For Models: SBS, SBD, SBN, SDV, SUF, PCE and CSB. Prices Effective Commercial Water Heater Replacement Parts Price List For Models: SBS, SBD, SBN, SDV, SUF, PCE and CSB Prices Effective October 2, 2006 This parts price catalog supercedes book number SCBPB00306 and all

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl100rnl, BFL125RNL Item Stock Number(s): BFL100RNL, BFL125RNL IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-400 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003

More information

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide e Bath Fan with Light User s Guide abfl50uq, BFL60UQ, BFL70, BFL85 Item Stock Number(s): BFL50UQ, BFL60UQ, BFL70, BFL85 IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY

More information

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) CONTROL BOX KIT (12 VDC HEAT/COOL)

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) CONTROL BOX KIT (12 VDC HEAT/COOL) INSTALLATION INSTRUCTIONS FOR 8330-5511 MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) 9330-755 CONTROL BOX KIT (12 VDC HEAT/COOL) 7530B750 CONTROL BOX KIT (24 VAC COOL ONLY) 9530-755 CONTROL

More information

Your safety and the safety of others are very important.

Your safety and the safety of others are very important. VARIABLE SPEED ELECTRIC FURNACE INSTALLATION INSTRUCTIONS VARIABLE SPEED ELECTRIC FURNACE SAFETY...1 INSTALLATION REQUIREMENTS...2 Tools and Parts...2 Location Requirements...2 Installation Configurations...3

More information

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING See unit nameplate for manufacturer and address. 506380 01 11/2009 KGA024, 030, 036, 048, 060, 072 (2, 2 1/2, 3, 4, 5, and 6 Tons) KGA092, 102, 120, 150 (7 1/2, 8-1/2, 10, and 12 Tons) KGA180, 210, 240,

More information

INSTALLATION & OPERATING INSTRUCTIONS. Roof Top Unit. Model. USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516

INSTALLATION & OPERATING INSTRUCTIONS. Roof Top Unit. Model. USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516 RECORD THIS INFORMATION FOR FUTURE REFERENCE: Model Number Serial Number ADB Model Number ADB Serial Number Date Purchased USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516

More information

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING See unit nameplate for manufacturer and address. 507350-03 3/2016 Supersedes 9/2015 KG 024, 030, 036, 048, 060, 072, 074, 090 (2, 2-1/2, 3, 4, 5, 6 and 7-1/2 Tons) KG 092, 102, 120, 150 (7-1/2, 8 1/2,

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVO-200 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVO-200 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per CSA B140.8 Portable Oil Fired Heaters / CSA B140.02003

More information

Installation Instructions

Installation Instructions PART NUMBER: 001A00 002A00 SMALL PACKAGED PRODUCTS 2 TO 5 TONS (50/60 HZ) MOTORMASTER II HEAD PRESSURE CONTROLLER Installation Instructions NOTE: Read the entire instruction manual before starting the

More information

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT H6HK Series Electric Heater Kit INSTALLATION INSTRUCTIONS Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT These instructions are primarily intended to assist qualified individuals

More information

LGB Gas fired boiler

LGB Gas fired boiler LGB Gas fired boiler Control Supplement LGB-5 Series 2 Propane gas CSD-1 Control System Part Number 550-110-682/0304 Please read this page first Hazard definitions To the installer... The following terms

More information

NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER. c_::_':_-_:_ r'" _" "_1 WARNING: If the information in this manual is not followed exactly, a fire or explosion may Iresult causing property damage, personal injury or [loss of life. m m m Do not store

More information

Installation Instructions

Installation Instructions 40MBFQ Floor Console Ductless System Sizes 09 to 12 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS... 5 CLEARANCES... 5

More information

Models CHB/CCB APPLICATION GUIDE WALL MOUNTED GAS BOILER

Models CHB/CCB APPLICATION GUIDE WALL MOUNTED GAS BOILER Models CHB/CCB APPLICATION GUIDE WALL MOUNTED GAS BOILER This manual has been prepared for use with the appropriate Installation, Operation and Maintenance Manual. For use with CCB/CHB Boilers ONLY. Manufactured

More information

Service and Maintenance Instructions

Service and Maintenance Instructions Service and Maintenance Instructions HSI Mid-Efficiency Induced-Combustion Furnaces Sizes 050 thru 155 Series C GB1AAV GB3AAV TE: Read the entire instruction manual before starting the installation. These

More information

Installation, Operation & Maintenance: Field-Installed Electric Heater for RXT Series Units

Installation, Operation & Maintenance: Field-Installed Electric Heater for RXT Series Units P.O. Box 245 Syracuse, NY 13211 www.roth-america.com 888-266-7684 Installation, Operation & Maintenance: Field-Installed Electric Heater for RXT Series Units P/N: 2300100902 Table of Contents: Section

More information

FIREPLACE INSTALLATION

FIREPLACE INSTALLATION CHECK GAS TYPE Use proper gas type for the fireplace unit you are installing. If you have conflicting gas types, do not install fireplace. See retailer where you purchased the fireplace for proper fireplace

More information

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) For FVN/P-400 INDIRECT FIRED SPACE HEATERS CERTIFIED FOR USE IN CANADA AND U.S.A. As per Standard ANSI Z83.7/CSA 21.4 2000 Gas Fired Construction

More information

V SERIES HDR GAS RANGES

V SERIES HDR GAS RANGES SERVICE MANUAL ONE POWERFUL PACKAGE V SERIES HDR GAS RANGES TOPS Open Top Hot Top Griddle Top Work Surface BASES Standard Oven Convection Oven Cabinet Base - NOTICE - This manual is prepared for use by

More information

14PRR62XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 14PRR62(X)

14PRR62XXD Series Fan. Owner s Guide and Installation Manual. ETL Model NO. : 14PRR62(X) Owner s Guide and Installation Manual 14PRR62XXD Series Fan ETL Model NO. : 14PRR62(X) Attach sales receipt to this card and retain as your proof of purchase DATE OF PURCHASE: MODEL NUMBER: RETAILER NAME:

More information

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT RV Products Division INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330A755 CONTROL BOX KIT (12 VDC HEAT/COOL) 8530-750 CONTROL BOX KIT (24 VAC COOL ONLY)

More information

Installation Instructions

Installation Instructions Installation Instructions Electric Drop-In Range JDS28, JDP39 Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: ge.com BEFORE YOU BEGIN Read these instructions carefully and completely.

More information

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT RV Products Division INSTALLATION INSTRUCTIONS FOR 8330-5501 MOUNTING KIT 8330-752 CONTROL BOX KIT (12 VDC COOL ONLY) 9330B755 CONTROL BOX KIT (12 VDC HEAT/COOL) 8530-750 CONTROL BOX KIT (24 VAC COOL ONLY)

More information

Installation & Troubleshooting Requirements

Installation & Troubleshooting Requirements Installation & Troubleshooting Requirements Wiring Diagram Operation Sequence Presumptions: Main valve knob should always remain in the ON position Gas is bled to the valve Electrical is properly connected

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Electric Heat Sections Used with Blower Coil Units ELECTRIC HEAT SECTIONS 505,084M (0655012-30) 05/15 Supersedes 09/11 Litho U.S.A. NOTICE TO INSTALLER IT IS HIGHLY RECOMMENDED

More information

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING See unit nameplate for manufacturer and address. 507258-04 7/2018 Supersedes 10/2017 ZG 036, 048, 060, 072, 074 (3, 4, 5 and 6 Tons) ZG 092, 102, 120, 150 (7-1/2, 8-1/2, 10 and 12 Tons) ROOFTOP UNITS ZG

More information

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE

More information

e Heater/Exhaust Fan/Light User s Guide

e Heater/Exhaust Fan/Light User s Guide e Heater/Exhaust Fan/Light User s Guide abflh70l, BFLH85L Item Stock Number(s): BFLH70L, BFLH85L IMPORTANT INSTRUCTIONS - OPERATING MANUAL READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Keep these instructions with the boiler at all times. BOYERTOWN FURNACE CO. PO Box 100 BOYERTOWN, PA 19512 1-610-369-1450 www.boyertownfurnace.com 5-25-12 2 Danger Warning Caution

More information