1 P.O. Box 245 Syracuse, NY Installation, Operation & Maintenance: Field-Installed Electric Heater for RXT Series Units P/N: Table of Contents: Section 1: Model Nomenclature Model Nomenclature...2 Section 2: Safety Labeling and Signal Words Warnings, Cautions, and Notes...2 Guide Revision Table: Date By Page Note August 2010 KT All First Published Section 3: Introduction Introduction, Inspection, Definition, Unit Protection...3 Section 4: Installation Overview, Considerations, Installation Steps Section 5: Electrical Data AHTR Electric Heat Electrical Data...6 Section 6: Wiring Diagrams AHTR101B / 10kW...7 AHTR151B / 15kW...8 AHTR201B / 20kW...9 Section 7: Parts Lists AHTR101B / 10kW...10 AHTR151B / 15kW...11 AHTR201B / 20kW...12
2 Section 1: Model Nomenclature 1 & 2: Family 3 & 4: Type 5 & 6: Capacity 7: Voltage AH TR 10 1 B 8: Revision Family: AH = Field Installed Electric Heater Type: TR = Field Installed Used on RXT Series Models Revision: B = Current Revision Voltage: 1 = 208/230V, 60Hz, 1 Phase Capacity: 10kW 15kW 20kW Rev.: 14 July 2010D Section 2: Safety Labeling and Signal Words DANGER, WARNING, CAUTION, and NOTE The signal words Danger, Warning, Caution, and Note are used to identify levels of hazard seriousness. The signal word Danger is only used on products label to signify and immediate hazard. The signal words Warning, Caution, and Note will be used on product labels and throughout this manual and other manuals that may apply to this product. NOTICE Notification of installation, operation or maintenance information which is important, but which is NOT hazard-related. CAUTION Indicates a potentially hazardous situation or an unsafe practice which, if not avoided, COULD result in minor or moderate injury or product or property damage. Signal Words in Manuals The signal word WARNING is used throughout this manual in the following manner: WARNING The signal word CAUTION is used throughout this manual in the following manner: CAUTION Signal Words on Product Labeling Signal words are used in combination with colors and/or on product labels. WARNING Indicates potentially hazardous situation which, if not avoided, COULD result in death or serious injury. DANGER Indicates an immediate hazardous situation which, if not avoided, WILL result in death or serious injury. Note: Used to highlight suggestions which will result in enhanced installation, reliability, or operation. Roth 2 AHTR Series Elec Heat IOM, August 2010
3 Section 3: Introduction INTRODUCTION The AHTR electric heater is designed specifically for the RXT Series Geothermal Heat Pump Unit. Engineering and quality control is built into every electric heater assembly. Good performance depends on proper application and correct installation. The information contained in this manual is intended for use by a qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments. Shut OFF electric power at unit disconnect and/or service panel before beginning the following procedures. WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury, property damage and/or death. Installation or repairs made by unqualified persons can result in hazards to you and others. Installation must conform with local building codes or, in the absence of local codes, with National Electrical Code ANSI/ NFPA or current edition. INSPECTION Upon receipt of any geothermal accessory, carefully check the shipment against the packing slip and the freight company bill of lading. Verify that all units and packages have been received. Inspect the packaging of each package and each unit for damages. Insure that the carrier makes proper notation of all damages or shortage on all bill of lading papers. Concealed damage should be reported to the freight company within 15 days. If not filed within 15 days the freight company can deny all claims. Note: Notify Roth s shipping department of all damages within 15 days. It is the responsibility of the purchaser to file all necessary claims with the freight company. UNIT PROTECTION Protect units from damage and contamination due to plastering (spraying), painting and all other foreign materials that may be used at the job site. Keep all units covered on the job site with either the original packaging or equivalent protective covering. Cap or recap unit connections and all piping until unit is installed. Precautions must be taken to avoid physical damage and contamination which may prevent proper start-up and may result in costly equipment repair. OVERVIEW This instruction covers the physical installation of the AHTR Series electric heat kits when installed with the RXT Series Geothermal Heat Pump unit. The electric heat accessories are used for applications of heat pump with electric heat. Each of the unit models are approved for use with specific electric heat accessories. The installation instructions list the possible combinations and other important electrical data and limitations. Table 1: Heater Compatibility Model Ahtr101b Ahtr151b Ahtr201b Accessory Heater Usage Description 10kW, 60Hz, 1 Phase w/circuit Breaker 15kW, 60Hz, 1 Phase w/circuit Breaker 20kW, 60Hz, 1 Phase w/circuit Breaker Note: AHTR electric heaters are not backward compatible. Used With RXT Model Adapter and filler plates are shipped with the indoor units to be used with electric heat as needed depending on unit size and heater size. AHTR Series Elec Heat IOM, August Roth
4 Section 4: Installation INSTALLATION This instruction covers the physical installation of the AHTR Series electric heat kits when installed with the RXT Series Geothermal Heat Pump Unit. The electric heat accessories are used for applications of heat pump with electric heat. Each of the air handler unit models are approved for use with specific electric heat accessories. The installation instructions list the possible combinations and other important electrical data and limitations. 1. Shut OFF electrical power at unit disconnect switch or service panel. 2. Remove the upper front panel from unit and locate filler plate. Remove the (4) sheet metal screws from plate. (See Figure 1) Figure 1: Heater Installation Heater Support Rod Fits into Hole Rotate Circuit Breakers 180 Degrees for RH and LH DN Airflow WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death. Before installing, modifying, or servicing system, main electrical disconnect switch must be in the off position. There may be more than one disconnect switch. Lock out and tag switch with suitable warning label. CAUTION CUT HAZARD Failure to follow this caution may result in personal injury. Sheet metal parts may have sharp edges or burrs. use care and wear protective clothing and gloves when handling parts. Representative drawing only, some models may vary in appearance. RIGHT HAND AIRFLOW AND LEFT HAND DOWNFLOW APPLICATION 3. If unit is going to be used for right hand return or left hand return downflow (airflow) the circuit breakers will have to be removed and rotated 180 degrees, so the OFF position will be DOWN when the cabinet is positioned on the right side. This is an NEC requirement. DO ONE BREAKER AT A TIME to make sure wires are reconnected properly. Loosen terminal screws on the wires. Gently pull wires back from breaker. Remove screws securing the breaker and rotate 180 degrees, then reconnect the wires to breaker. Proper torque for terminal screws is 35 inch pounds. 4. Insert the heater into the cabinet opening as shown in Figure 1, so the heater support rod goes into the hole in the back of the plenum. Exercise caution to prevent damage to heater element. 5. Secure the electric heat accessory with four screws. Roth 4 AHTR Series Elec Heat IOM, August 2010
5 Section 4: Installation LOW VOLTAGE WIRING 6. Connect the 6-Pin heater wiring harness to the receptacle located inside the cabinet (Top Cover). A perfect match and positive connection must be made between the plug and receptacle. The plug will interlock with receptacle when properly seated. Harness contains 24 Volts wiring. WIRING 7. Route unit power supply through knockout in top of unit and connect to line side of disconnect. Connect ground wire to ground lug. See wiring diagram label to make connections. All line voltage connections and ground connections MUST be made with copper wire. The power supply wiring MUST have overcurrent protection. This can be either fuses or circuit breakers. The maximum size for the overcurrent protection is shown in the column labeled Max. Fuse or NEC HACR Breaker (Amps) in the electrical Data Table or on the unit rating plate. Connect supply voltage wires to the Circuit Breakers on the heater or to the terminal block on the heater. NOTE: Supply voltage, amperage, fuse and disconnect switch sizes MUST conform with all technical specifications in this manual and on the unit rating plate. GROUNDING 8. Permanently ground the electric heat accessory in accordance with local codes and ordinances and in the United States with National Electrical Code ANSI/NFPA or current edition. Use a copper conductor of the appropriate size from the electric heat accessory ground lug, to a grounding lug on the circuit breaker panel. On models with more than one circuit, a separate copper ground wire MUST be connected for each circuit. 8. Install top front door panel. 9. Mark an X in the appropriate box for the heater on the unit rating plate. WARNING ELECTRICAL SHOCK HAZARD The unit cabinet must have an uninterrupted or unbroken ground to minimize personal injury if an electrical fault should occur. The ground may consist of electrical wire or metal conduit when installed with existing electrical codes. TIME DELAY MODULE 10. The time delay module stages the heater elements for 15kW and 20kW heaters. In most cases, all of the DIP switches should be in the ON position, which will provide a 1,023 second (approximately 17 minute) delay between the first and second stage of electric heat. For example, if all of the switches are in the ON position of a 20kW heater, only 10kW will be energized when the thermostat calls for backup or emergency heat. After approximately 17 minutes of continuous demand from the thermostat, the second bank of electric heat will be energized, providing the full 20kW of heat. The DIP switches may be set in any manner that is desired. There are 10 DIP switches that are cumulative. In other words, starting with the first switch, the time delay for each additional switch that is in the ON position is added to the previous switch. The switches are labeled 1, 2, 4, 8, 16, 32, 64, 128, 256, and 512. When all of the switches are in the ON position, all of the numbers must be added to determine the time delay. In the case of all switches in the ON position, the delay is = 1,023 seconds. If only 8 to 9 minutes is desired between stages, place all AHTR Series Elec Heat IOM, August Roth
6 Section 4: Installation but the last switch (the switch labeled 512 ) in the ON position. With 9 switches in the ON position, the time delay is = 511 seconds (about 8.5 minutes). Other combinations of switches may be used, depending upon the desired time delay. AIR FLOW 11. Airflow requirements are different between models. Please refer to the unit Installation Instructions for airflow set-up information. TEMPERATURE RISE CHECK 12. Temperature rise is the difference between the supply and return air temperatures. NOTE: The temperature rise can be adjusted by changing the heating CFM. Refer to the unit s Installation Instructions for airflow information. NOTE: The maximum outlet air temperature for all models is 200 Degrees F (93.3 Degree C). Section 5: Electrical Data Heater Model AHTR101B AHTR151B AHTR201B Supply Voltage Heat kw TECHNICAL DATA (AHTR Electric Heaters only) Single Phase w/ Circuit Breaker Supply Circuit Number Heater kw Per Circuit FLA Total AMPS MCA Min Circuit Ampacity Maximum Over- Current Protective Device (AMPS.) # of Wires Supply Wire 75 C. Copper Wire Size Recommended Max Length (Ft) # of wires Ground Wire Single Single Mult Mult Mult Mult Mult Mult Mult Mult Min Size Roth 6 AHTR Series Elec Heat IOM, August 2010
7 Section 6: Wiring Diagrams - AHTR101B / 10kW AHTR Series Elec Heat IOM, August Roth
8 Section 6: Wiring Diagrams - AHTR151B / 15kW Roth 8 AHTR Series Elec Heat IOM, August 2010
9 Section 6: Wiring Diagrams - AHTR201B / 20kW AHTR Series Elec Heat IOM, August Roth
10 Section 7: Parts List - AHTR101B / 10kW Roth 10 AHTR Series Elec Heat IOM, August 2010
11 Section 7: Parts List - AHTR151B / 15kW AHTR Series Elec Heat IOM, August Roth
12 Section 7: Parts List - AHTR201B / 20kW Roth 12 AHTR Series Elec Heat IOM, August 2010
13 AHTR Series Elec Heat IOM, August Roth
14 P.O. Box 245 Syracuse, NY US CAN FAX * ** *** * AHRI certification is shown as the Roth brand under the Enertech Manufacturing certification reference number **Roth Industries geothermal heat pumps are shown as a multiple listing of Enertech Manufacturing s ETL certification *** Roth geothermal heat pumps are listed as a brand under Enertech Manufacturing s Energy Star ratings
Installation Instructions
Installation Instructions EHMA SERIES ELECTRIC HEATERS FOR PAM3 SERIES PACKAGE AIR CONDITIONERS PHM3 SERIES PACKAGE HEAT PUMPS TABLE OF CONTENTS SAFE INSTALLATION REQUIREMENTS... 2 GENERAL INFORMATION...
More informationINSTALLATION INSTRUCTIONS ELECTRIC HEAT ACCESSORY
INSTALLATION INSTRUCTIONS ELECTRIC HEAT ACCESSORY EHK05AKN/B, EHK07AKN/B, EHK10AKN/B, EHK15AKF/B, EHK20AKF/B, EHK15AHN, EHK18AHN, EHK09AKCN, EHK25AHCF, EHK30AHCF Safety Labeling and Signal Words DANGER,
More informationElectric Heat Accessory Installation Instructions
Electric Heat Accessory Installation Instructions EBP, EBX, EBV, EBW FVM, FEM, FSM, FSU WARNING Electrical shock hazard. Installation or repairs made by unqualified persons can result in hazards to you
More informationElectric Heat Accessory
Electric Heat Accessory AMFK05CHA AMFK05CHB AMFK07CHA AMFK07CHB AMFK0CHA AMFK0CHB AMFK4CHB AMFK20CHB AMFK25CHB AMFK30CHB Single Phase For Use ith Blower & Fan Coil Units and Electric Furnaces ANING Electrical
More informationInstallation Instructions
50ES---A, 50EZ---A, 50VL---A, 50VG---A, 50VR---A, 50VT---A, 604D--- ---A, 607C--- ---A, 607E,--- ---A, 704D--- ---A, 707C--- ---A, 707E--- ---A PA3G --- --- A, PH3G --- --- A SMALL PACKAGED PRODUCTS Electric
More information*20D082-05NN* 20D082-05NN
2506 South Elm Street Greenville, IL 62246 www.enertechgeo.com info@enertechmfg.com HT Models Packaged Water-to-Air Horizontal Heat Pumps Engineering Data and Installation Manual Rev.: 25 May 2012D P/N:
More informationDesuperheater Fitting Kit Installation Guide
P.O. Box 245 Syracuse, NY 13211 www.roth-america.com 888-266-7684 Desuperheater Fitting Kit Installation Guide P/N: 2300100908 Table of Contents: Section 1: Introduction Contents of Kit... 2 Guide Revision
More informationInstallation Instructions
Electric Heater Packages Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing and servicing of heating and air conditioning
More informationInstallation Instructions
EHNA Electric Heaters 5-20kW For 60 Hz Small Packaged Products MODELS: PAD3, PHD3, PAD4, PHD4, PAD5, PHD5, WPA3, WPH3 Installation Instructions NOTE: Read the entire instruction manual before starting
More informationInstallation Instructions
50ES--A, 50EZ--A, 50VG--A, B, 50VL--A, B, 50VR--A, 50VT--A, B 604D-- --A, 607C-- --A, B, 607E-- --A, 704D-- --A, 707C-- --A, B, 707E-- --A PA3G -- -- A, PH3G -- -- A, PA4G, PH4G PAD3, PHD3, PAD4, PHD4,
More informationInstallation Instructions
Installation Instructions Electric Heater Packages KFAEH TE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SINGLE-CIRCUIT GROUND
More informationInstallation Instructions
Installation Instructions Electric Heater Packages With DC Relay KFCEH NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SINGLE-CIRCUIT
More informationInstallation Instructions
Electric Heater Packages Installation Instructions TE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing and servicing of heating and air conditioning
More informationInstallation Instructions
Installation Instructions Electric Heater Packages KFAEH -CIRCUIT GROUND LUG TERMINAL BLOCK MULTI-CIRCUIT GROUND LUG COOLING CONTROL PLATE ADAPTER PLATE (MUST BE REMOVED WHEN INSTALLING LARGE HEATER) BLOCK
More informationInstallation Instructions
Electric Heater Kit For use with GC Geothermal Heat Pumps KWCEH0101B05 KWCEH0101B10 KWCEH0101B15 KWCEH0101B20 Installation Instructions NOTE: Read the entire instruction manual before starting the installation.
More informationInstallation in Standard & Variable Speed Indoor Air Handlers IMPORTANT
H6HK Series Electric Heater Kit INSTALLATION INSTRUCTIONS Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT These instructions are primarily intended to assist qualified individuals
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Models MB08B1500A2 MB12F1900A2 MB16J2200A2 MB20N2600A2 Contents 115 Volt General Information / Installation... 2 Installations... 3 Horizontal Installations... 3 Ductwork Connections...
More informationInstallation Instructions
50ZPB, C, 50ZHB, C, PA3Z ---A, PH3Z ---A, PA4Z, PH4Z, PAJ4,PHJ4,WJA4,WJH4 SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters 5---20 kw For 14 SEER, R---410A Manufactured Home Installation Instructions
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Electric Heat Sections Used with Blower Coil Units ELECTRIC HEAT SECTIONS 505,084M (0655012-30) 05/15 Supersedes 09/11 Litho U.S.A. NOTICE TO INSTALLER IT IS HIGHLY RECOMMENDED
More informationInstallation Instructions
Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A Manufactured Home Installation Instructions NOTE: The Dual Point Kit can only be installed on
More informationInstallation Instructions
HC2 HC3 HOT WATER COILS MULTIPOISE Installation Instructions NOTE: Read the entire installation instructions before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration,
More informationInstallation Instructions
Electric Heaters 5 --- 20 kw SMALL PACKAGED PRODUCTS (SPP) Accessory Electric Heaters For 13 SEER, R---410A, Z Chassis Installation Instructions NOTE: Read the entire instruction manual before starting
More informationCLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. I 2017 Pentair Equipment Protection P/N
CLIMAGUARD Air-to-Air Outdoor Heat Exchangers TX23, TX33, TX38, TX52 Models INSTRUCTION MANUAL Rev. I 2017 Pentair Equipment Protection P/N 10-1008-221 87976519 TABLE OF CONTENTS Warranty and Return Policy...2
More informationInstallation Instructions
Installation Instructions PAM3 SERIES PACKAGE AIR CONDITIONERS TABLE OF CONTENTS SAFETY LABELING AND SIGNAL WORDS... 2 UNIT DIMENSIONS... 3 SAFE INSTALLATION REQUIREMENTS... 3 LOCATING THE UNIT... 3 CLEARANCES...
More informationInstallation Instructions
Electric Heater Kit For use with GB, GP and GT eries Geothermal Heat Pumps KWAEH0101N05 KWAEH0101N10 KWAEH0101F15 KWAEH0101F20 Installation Instructions NOTE: Read the entire instruction manual before
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS FCP2400D FCP3000D FCP3600D FCP4200D FCP4800D FCP6000D FCP2400C FCX2400C FCP3000C FCP3600C FCX3600C FCP4200C FCP4800C FCX4800C FCP6000C FCX6000C Require AMF001NHA Accessory No
More informationInstallation Instructions
CAELHEAT001A00 - CAELHEAT039A00 AAHC05AHAA - AAHC70ESAA PACKAGED AIR---HANDLING UNITS ELECTRIC HEAT ACCESSORY 6 to 30 TONS (21 to 105 kw) 50/60 Hz Installation Instructions TABLE OF CONTENTS SAFETY CONSIDERATIONS...
More informationYour safety and the safety of others are very important.
VARIABLE SPEED ELECTRIC FURNACE INSTALLATION INSTRUCTIONS VARIABLE SPEED ELECTRIC FURNACE SAFETY...1 INSTALLATION REQUIREMENTS...2 Tools and Parts...2 Location Requirements...2 Installation Configurations...3
More informationInstallation Instructions
CRHEATER270A00 - ELECTRIC HEATER ACCESSORY SINGLE PACKAGE ROOFTOP UNITS 15 to 27.5 TONS Installation Instructions TABLE OF CONTENTS SAFETY CONSIDERATIONS... 1 GENERAL... 1 MODEL/CAPACITY TABLES... 2-11
More informationEarthLinked AVN Series Air Handlers Installation Manual
EarthLinked AVN Series Air Handlers Installation Manual AVN-410-IM (03/14) Copyright 2014 Earthlinked Technologies, Inc. Table of Contents Model Nomenclature... 4 Safety... 5 Equipment Manuals... 5 Installation...
More informationInstallation Instructions
Electric Heaters 5 --- 20 kw Installation Instructions SMALL PACKAGED PRODUCTS 2to5Tons Accessory Electric Heaters (Single---Point Connection) NOTE: Read the entire instruction manual before starting the
More informationClimaGuard Outdoor Heat Exchanger All Models
INSTRUCTION MANUAL ClimaGuard Outdoor Heat Exchanger All Models Exceeding Expectations. McLean Cooling Technology 11611 Business Park Blvd N Champlin, MN 55316 USA Tel 763-323-8200 Fax 763-576-3200 www.mcleanparts.net
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Models FCV3600A FCV4800A FCV6000A Require AMF001NHA Accessory No Heat Kit Contents Use ONL factory listed electric heaters. General Information / Installation... 2 Upflow Installations...
More informationFAILURE TO FOLLOW THESE INSTRUCTIONS CAN CAUSE FIRE, EXPLOSION, ELECTRICAL SHOCK, PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
HKR ELECTRIC HEAT KIT INSTALLATION INSTRUCTIONS AT TENTION INST NSTALLING PERS ERSONNEL As a professional installer, you have an obligation to know the product better than the customer. This includes all
More informationB SERIES ELECTRIC FURNACE
MISSISSAUGA, ONTARIO L5T 1H9 TEL.: 905-670-2500 FAX: 905-795-8311 CUSTOMER SERVICE TEL.: 1-888-882-7626 B SERIES ELECTRIC FURNACE! WARNING 1. The user MUST contact a specialized contractor when a failure
More informationDVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV
DVPVC Multi-Position, Variable-Speed Air Handler Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications...3
More informationInstallation Instructions
H6HK Series Installation Instructions Electric Heater Kits Installation in Standard and Variable Speed Indoor Air Handlers IMPORTANT: The instructions included with this heater kit are for installations
More informationAUXILIARY ELECTRIC HEATER KITS FOR 7.5 AND 10 TON COMMERCIAL AIR HANDLERS
AUXILIARY ELECTRIC HEATER KITS FOR 7.5 AND 10 TON COMMERCIAL AIR HANDLERS WARNING: THIS ACCESSORY IS TO BE INSTALLED BY A QUALIFIED, LICENSED SERVICE PERSON. TO AVOID UN- SATISFACTORY OPERATION OR DAMAGE
More informationFSS-Series Heavy-Duty Flat panel Emitter Electric Overhead Infrared Heaters
TPI Corporation P.O. Box 4973 Johnson City, TN 37602 www.tpicorp.com FSS-Series Heavy-Duty Flat panel Emitter Electric Overhead Infrared Heaters FSS-14 FSS-43 FSS-31 FSS-95 IMPORTANT SAFETY INFORMATION
More informationElectric Heat Accessory Installation Instructions
Electric Heat Accessory Installation Instructions EHK05AKN/B, EHK07AKN/B, EHK10AKN/B, EHK15AKF/B, EHK0AKF/B, EHK15AHN, EHK1AHN, EHK09AKCN, EHK5AHCF, EHK30AHCF Safety Labeling and Signal Words DANGER, WARNING,
More informationWMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS
WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS **WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER** Altering the product or replacing parts with non authorized factory parts voids all warranty
More informationAR SERIES COMMERCIAL AIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS
AR SERIES COMMERCIAL AIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS NOTE: AR models are suitable for Upflow and Horizontal Installations only. Do not use for Downflow Installations RECOGNIZE THIS SYMBOL
More informationINSTALLATION INSTRUCTIONS R 410A Single Package Rooftop Heat Pump RHS
INSTALLATION INSTRUCTIONS R 410A Single Package Rooftop Heat Pump RHS090 120 These instructions must be read and understood completely before attempting installation. DANGER, WARNING, CAUTION, and NOTE
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS C7BA Series Split System Indoor Cased Coils IMPORTANT ATTENTION INSTALLERS: It is your responsibility to know this product better than your customer. This includes being able
More informationEarthLinked AFN Series Air Handlers Installation Manual
EarthLinked AFN Series Air Handlers Installation Manual AFN-410-IM (07/15) Copyright 2015 Earthlinked Technologies, Inc. Table of Contents Model Nomenclature... 4 Safety... 5 Equipment Manuals... 5 Installation...
More informationVERTICAL MOUNT AIR HANDLERS
VERTICAL MOUNT AIR HANDLERS INSTALLATION INSTRUCTIONS 2005-2009 Goodman Manufacturing Company, L.P. 5151 San Felipe, Suite 500, Houston, TX 77056 www.goodmanmfg.com -or- www.amana-hac.com P/N: IO-281J
More informationINSTALLATION INSTRUCTIONS
C7BA & C7BH Series Split System Indoor Cased Coils INSTALLATION INSTRUCTIONS IMPORTANT It is your responsibility to know this product better than your customer. This includes being able to install the
More informationDLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS
DLCLRA INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 Fig. 1 - Size 36 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING...
More informationInstallation Instructions
HHK Series Installation Instructions Electric Heater Kits Installation in Standard and Variable Speed Indoor Air Handlers! IMPOTANT: The instructions included with this heater kit are for installations
More informationMANUAL INSTALLATION. Fan Column. v200 Issue Date: 01/18/ Price Industries Limited. All rights reserved.
MANUAL INSTALLATION Fan Column v200 Issue Date: 01/18/17 2017 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview General Safety Information...1 Safety Notices...1 Unit Description...2
More informationFAN POWERED VAV TERMINALS
FAN POWERED VAV TERMINALS Models VFR, CFR and CFRQ INSTALLATION, OPERATION AND MAINTENANCE MANUAL All data herein is subject to change without notice. Refer to www.enviro-tec.com for current catalog data
More informationMODELS B1PA024, 030 AND 036
STELLAR 2000 SINGLE PACKAGE HEAT PUMPS INSTALLATION INSTRUCTION Supersedes: 511.26-N1Y (892) 511.26-N1Y (893) MODELS B1PA024, 030 AND 036 035-11622 GENERAL YORK Model B1PA units are factory assembled heat
More informationDVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons
DVPEC Multi-Position, Variable-Speed air handler Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Airflow
More informationAVPTC. Air Handlers 1½ to 5 Tons
Multi-Position, Variable-Speed Air Handlers ½ to Tons Standard Features Compatible with the ComfortNet Communicating System family of products R-0A refrigerant-compatible Factory-installed thermal expansion
More informationInstallation Instructions Remote Blowers
Installation Instructions Remote Blowers Models: REMP3, REMP16 Suitable for use in a household cooking area. Suitable for use with solid state controls. To complete this blower, a Dacor hood assembly or
More informationInstallation Instructions
38MHR Outdoor Unit Single Zone Ductless System Sizes 09 to 24 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. NOTE: Images are for illustration purposes
More informationFSA-Series Heavy-Duty Flat panel Emitter Architectural Electric Overhead Infrared Heaters
TPI Corporation P.O. Box 4973 Johnson City, TN 37602 www.tpicorp.com FSA-Series Heavy-Duty Flat panel Emitter Architectural Electric Overhead Infrared Heaters FSA-14 FSA-43 FSA-31 FSA-95 IMPORTANT SAFETY
More informationINSTALLATION INSTRUCTIONS
INSTALLATIN INSTUCTINS Models M08B500A2 M2F900A2 M6J2200A2 M20N2600A2 equire AMF00NHA Accessory No Heat Kit Contents Use NL factory listed electric heaters. Modular Blower (ariable Speed) Safety Labeling
More informationINSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121
INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS Model: WA121 Bard Manufacturing Company Bryan, Ohio 43506 Since 1914...Moving ahead just as planned. Manual : 2100-234 G Supersedes: 2100-234
More informationInstallation Instructions
40MBFQ Floor Console Ductless System Sizes 09 to 12 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 DIMENSIONS... 5 CLEARANCES... 5
More informationMBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features
Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible Contents MBVC Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Airflow Data... Heat Kit Data...
More informationMBR. Multi-Position. Modular Blower
M Product Features Direct drive, multi-speed PSC blower motor kw 1 kw electric heat kits Blower section usable as electric heater Horizontal or vertical configuration capabilities 1" depth for easier attic
More informationINSTALLATION MANUAL WARNING WARNING MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: MA LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES
INSTALLATION NUAL MODULAR NON-VARIABLE SPEED AIR HANDLERS MODELS: GENERAL.............................................. 1 SAFETY................................................ 1 UNIT INSTALLATION.....................................
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS C8DA Series Split System Uncased Indoor Coils - Downturn IMPORTANT ATTENTION INSTALLERS: It is your responsibility to know this product better than your customer. This includes
More informationE-Z Zone Pack 3+1 And 5+1 Boiler Manifold System
INSTALLATION INSTRUCTIONS E-Z Zone Pack 3+1 And 5+1 Boiler Manifold System Keep these instructions with the boiler at all times BOYERTOWN FURNACE CO. PO Box 100 BOYERTOWN, PA 19512 1-610-369-1450 www.boyertownfurnace.com
More informationInstallation Instructions
HUMBBSFP1016 HUMCCSFP1016 Small Fan Powered Humidifier and Humidistat Installation Instructions! WARNING ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death.
More informationRittling Fanvector. Installation, Operation and Maintenance. Cooling Fresh Air Clean Air
Rittling Fanvector Installation, Operation and Maintenance Heating Cooling Fresh Air Clean Air i Arrangements 1 General information 1 Dimensions and data 2 Installation 6 Wiring diagram 9 Operation 10
More informationInstallation Instructions
H5HK Series Installation Instructions 3 Phase Electric Heater Kits Light Commercial Package A/C and Heat Pump Systems Description Installation of 208/240V and 480V H5HK 3 Phase Heater Kits in 6, 7.5 and
More informationAVS Air Handlers Installation Manual for Classic SC, SD, and SDH
AVS Air Handlers Installation Manual for Classic SC, SD, and SDH AVS-NCL-IM (12/15) Copyright 2015 Earthlinked Technologies, Inc. Table of Contents Model Nomenclature... 4 Safety... 5 Equipment Manuals...
More informationInstallation Instructions
---751,---754,---755,---756 Condensing Heat Exchanger Kit Installation Instructions NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation,
More informationViking Installation Guide
Viking Installation Guide Viking Range, LLC 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200 For product information, call 1-888-(845-4641) or visit the Viking Web site at vikingrange.com
More informationInstallation & Maintenance Instructions
PRH Series Plenum Heaters Installation & Maintenance Instructions Dear Owner, Congratulations! Thank you for purchasing this new heater manufactured by Marley Engineered Products. You have made a wise
More informationHeatrix Electric Duct Heater HXOB Installation Instructions
Heatrix Electric Duct Heater HXOB Installation Instructions General: Heatrix HXOB Style Electric Duct Heater has been tested and listed for close-coupled application with a forced air system (straight
More informationC7 Series Split System Uncased Indoor Coils
Installation Instructions C7 Series Split System Uncased Indoor Coils IMPORTANT ATTENTION INSTALLERS: It is your responsibility to know this product better than your customer. This includes being able
More informationAVPTC Multi-Position, Internal Txv
Multi-Position, Internal Txv Variable-Speed ECM Based Comfortnet Compatible Air Handler 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature......3 Dimensions...4 Airflow Data...5
More informationMBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor. Contents. Product Features
M Multi-Position, Multi-Speed Modular Blower With PSC Motor Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... 4 Airflow Data... 5 Heat Kit Data...
More informationMBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons. Contents. Product Features
MBVC Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Airflow Data...
More informationBosch BVA Series Air Handler
Bosch BVA Series Air Handler --- Ton Capacity R0A Product Specifications Product Specifications BVA Series Air Handler --- Ton Capacity R0A Air Handler Features Multi-speed ECM blower motor. Factory-installed
More informationADPF PRODUCT SPECIFICATIONS THREE-SPEED AIR HANDLER 1½ TO 5 TON DEDICATED DOWNFLOW
ADPF THREE-SPEED AIR HANDLER The ADPF Dedicated Downfl ow Three-Speed Air Handler is suitable for use with refrigerants R-410A and R-22. The unit features a check flowrater expansion device and may be
More informationInstallation Instructions
Installation Instructions Blower Packages For Gas Furnaces KCBBA00TG KCBBA00TG NOTE: Read the entire instruction manual before starting the installation. INTRODUCTION When upgrading a Coleman, Intertherm,
More informationINSTALLATION MANUAL. Double Electric Wall Oven
INSTALLATION MANUAL Double Electric Wall Oven 799258 BLUESTAR INSTALLATION INSTRUCTIONS FOR THE RESIDENTIAL ALL ELECTRIC WALL OVEN FOR THE HOME MODELS DEWO THIS APPLIANCE WAS DESIGNED FOR EASE OF INSTALLATION
More informationInstallation Instructions for Models: HES232U, HES236UHES246U, HES247U, HES245U, HES242U, HES256U, HES255U, HES252U
Freestanding Electric Range Household Appliances 2U Installation Instructions for Models: HES232U, HES236UHES246U, HES247U, HES245U, HES242U, HES256U, HES255U, HES252U PLEASE READ ENTIRE INSTRUCTIONS BEFORE
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS BUILT-IN FULL HEIGHT WINE CELLAR (VCWB300 PROFESSIONAL MODEL) Retain for Future Reference VIKING RANGE CORPORATION 111 Front Street Greenwood, Mississippi 38930 USA (662) 455-1200
More informationCELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler
CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual CELDEK Evaporative Cooler RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and
More informationINSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR / AHE SERIES LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: GENERAL
INSTALLATION MANUAL SINGLE PIECE, 3 POSITION AIR HANDLERS MODELS: AHR / AHE SERIES ISO 9001 Certified Quality Management System GENERAL..............................................1 SAFETY................................................1
More informationAdvantium TM. Built-In. Speedcook Ovens. Installation. Instructions
Advantium TM Built-In Speedcook Ovens Installation Instructions SCB2000, SCB2001 ZSC2000, ZSC2001 Before you begin Read these instructions completely and carefully. IMPORTANT - Save these instructions
More informationALIMENTATION 240 VAC POWER SUPPLY
ALIMENTATION 240 VAC POWER SUPPLY MULTI POSITION Models: FEM10-M2301CM-B FEM15-M2301CM-B FEM18-M2301CM-B FEM20-M2301CM-B FEM23-M2301CM-B FEM20-M2301DM-B FEM23-M2301DM-B FEM27-M2301DM-B DNS-0981 Rev. A
More informationFCI500/600/FVI500/FCL/FVL600/FCQ-700 Installation and Maintenance Manual
FCI500/600/FVI500/FCL/FVL600/FCQ-700 Installation and Maintenance Manual FAN POWERED TERMINALS Receiving Inspection Prior to removing the shipping material, visually inspect the packing materials. There
More informationUSER'S MANUAL/INSTALLATION INSTRUCTIONS
TM USER'S MANUAL/INSTALLATION INSTRUCTIONS P Series Single Package Convertible Air Conditioner Single Package Convertible Air Conditioner IMPORTANT These instructions are primarily intended to assist qualifi
More informationFor use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G
PGM-1 Cooktops For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G Install ation Instructions Part No. 65476 Rev. B Table of Contents Appliance Safety...1 Important Safety Instructions...2
More informationMBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS. Contents. Product Features
M Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS Contents Air Handler Nomenclature... Heater Kit Nomenclature... Product Specifications... Dimensions... 4 Airflow Data... 5 Heat
More informationPOSITION FEM10-M2301CM-A FEM15-M2301CM-A FEM18-M2301CM-A FEM20-M2301CM-A FEM23-M2301CM-A FEM20-M2301DM-A FEM23-M2301DM-A FEM27-M2301DM-A
ALIMENTATION 240 VAC POWER SUPPLY MULTI POSITION Models: FEM10-M2301CM-A FEM15-M2301CM-A FEM18-M2301CM-A FEM20-M2301CM-A FEM23-M2301CM-A FEM20-M2301DM-A FEM23-M2301DM-A FEM27-M2301DM-A DNS-0981 Rev. A
More informationInstallation. Built-in Full Height Wine Cellar VCWB301
Installation Built-in Full Height Wine Cellar VCWB301 Table of Contents Warnings & Important Information _ 3 Dimensions _ 5 Specifications _ 6 Cutout Dimensions 7 Cabinet Information _ 8 Cabinet Information
More informationINSTALLATION INSTRUCTION
INSTALLATION INSTRUCTION ELECTRIC HEAT S THRU 05 5 THRU Supersedes: (9) (00) 0-5 FOR SINGLE PACKAGE CONDITIONERS THRU TON SINGLE PACKAGE HEAT PUMPS THRU 5 TON GENERAL This instruction contains all the
More informationSM Field Installed Electric Heat Kit
SM Field Installed Electric Heat Kit HK050 HK100 HK150 HK200 Installation Manual 8733822029 (2018/07) US 2 SM Series Electric Heat Installation Manual Data subject to change 07.2018 8733822029 Installation
More informationInstallation Instructions
EZXCAB Sizes 016 and 020 High Efficiency Air Filtration System Installation Instructions JAN High Efficiency Air Filtration System Fig. 1 - EZXCAB C04001 NOTE: Read the entire instruction manual before
More informationAVS Series Air Handlers Installation Manual for CLASSIC SERIES SYSTEMS Models SC, SD, and SDH
AVS Series Air Handlers Installation Manual for CLASSIC SERIES SYSTEMS Models SC, SD, and SDH AVS-ACL-IM (08/15) Copyright 2015 Earthlinked Technologies, Inc. Table of Contents Model Nomenclature... 4
More informationFEM10-M2401AM-A FEM15-M2401AM-A FEM18-M2401AM-A FEM20-M2401AM-A FEM23-M2401AM-A FEM20-M2401BM-A FEM23-M2401BM-A FEM27-M2401BM-A
(3 WIRES 120/240 60 1) MULTI POSITION Models: FEM10-M2401AM-A FEM15-M2401AM-A FEM18-M2401AM-A FEM20-M2401AM-A FEM23-M2401AM-A FEM20-M2401BM-A FEM23-M2401BM-A FEM27-M2401BM-A DNS-0981 Rev. A INSTALLER /
More informationCROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS
CROWN Boiler Co Santa-Fe Series Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS These instructions must be affixed on or adjacent to the air handler Models: SAC049A20 SAC059A25
More informationInstructIon Manual KrEs EQuIPMEnt stands
Instruction Manual Instruction Manual SELF-CONTAINED AND REMOTE Kairak KRES model refrigerated equipment stand units are available in many lengths from 36 to 120 inches long. These units are available
More information