1 Mounting instructions Off-line filter - tank connection kit OLF-5-TAK Tank connection kit 2.0 Art. No last update 12 / 99 HYDAC Filtertechnik GmbH page 1 of 9
2 Trademarks The trademarks of other companies are exclusively used for the products of those companies. Copyright 1999 by HYDAC Filtertechnik GmbH All rights reserved. This manual may not be reproduced in part or whole without the explicit written agreement from HYDAC Filtertechnik. Contraventions are liable to compensation. Exclusion of liability We have used our best endeavours to ensure the accuracy of the contents of this document. However, errors cannot be ruled out. Consequently, we accept no liability for such errors as may exist nor for any damage or loss whatsoever which may arise as a result of such errors. The content of the manual is checked regularly. Any corrections required will be incorporated in subsequent editions. We welcome any suggestions for improvements. All details in this manual are subject to modification without advance notice. HYDAC FILTERTECHNIK GmbH Industriegebiet D Sulzbach/Saar Germany Tel: 06897/ Fax: 06897/ HYDAC Filtertechnik GmbH page 2 of 9
3 Content 1 Description Mounting DIMENSIONS AT THE ADAPTER FLOW RATES MOUNTING INSTRUCTIONS Return pipe Suction pipe Ventilation filter Seal Adapter Suction and return connection Mount ventilation filter...9 HYDAC Filtertechnik GmbH page 3 of 9
4 1 Description Use the 2.0 to quickly mount bypass filter units on hydraulic installations. This component can be mounted on installations with ventilation filter whose connections conform to DIN 24557/T2. Delivery partno: pce connection block 2 pcs seal for ventilation filter 5 pcs fillister head machine screws M5 x pce setscrew M5 x 8 1 pce return hose Ø 38 x 3, length 400 mm, 45 bevelled 1 pce suction hose Ø 26,9 x 2,3, length 800 mm with G3/4 thread on one side, at the free end 200 mm 90 offset. suction line: 1 pce straight screw fitting GE 22 L, G ¾ 1 pce hose DIN 20066, DN 20, 1 SN, length 1250 mm 2 pcs ell-bend 90 DIN 3942, 22L 1 pce straight screw fitting GE 22 L, G ½ return line: 2 pcs straight screw fitting GE 15 L, G ½ 1 pce hose DIN 20066, DN 12, 1 SN, length 1250 mm 2 pcs ell-bend 90 ISO 8434, 15L Delivery partno: pce connection block 2 pcs seal for ventilation filter 5 pcs fillister head machine screws M5 x pce setscrew M5 x 8 HYDAC Filtertechnik GmbH page 4 of 9
5 ventilation filter bypass filter unit ventilation S adapter R return hose suction hose HYDAC Filtertechnik GmbH page 5 of 9
6 2 Mounting 2.1 Dimensions at the adapter suction line connection thread S : G ¾ return line connection thread R : G ½ suction hose : G ¾ thread cut open on one side Dimension 26,9 x 2,3 DIN 2448 return hose : DIN 2391/C 45 angle cut on one side Dimension 38 x Flow rates flow rate [l/min] viscosity [mm²/s] suction pressure [bar] return pessure [bar] , ,1 0, ,06 0,5 46-0,06 0, ,2 1,5 60-0,18 1,2 The values were calculated using the delivered hoses and screwed connections (compare ch. 1 delivery): HYDAC Filtertechnik GmbH page 6 of 9
7 2.3 Mounting instructions Please proceed according to the following order: Return pipe has to be mounted in order to assure that the end of the pipe reaches beneath the oil level in the tank. Insert the return pipe into the adapter and fix it with the setscrew. It is possible to additionally glue it in place Suction pipe has to be fitted as far from the return pipe as possible (see drawing in ch. 1). Screw suction pipe into the adapter and glue it in place. If the suction pipe is too short add an oil resistant hose using a pipe clamp to connect it to the pipe. (hose not shown on the picture). HYDAC Filtertechnik GmbH page 7 of 9
8 2.3.3 Ventilation filter Dismount ventilation filter of hydraulic unit Seal Remove seal from tank cover and clean surface. Put new seal in place Adapter has to be mounted on oil tank with fillister head machine screws M5 x 120 and seal Suction and return connection Connect S to the suction connection and R to the return connection of the bypass filter unit. HYDAC Filtertechnik GmbH page 8 of 9
9 2.3.7 Mount ventilation filter Mount ventilation filter on the adapter with a new seal and the correct screws. HYDAC Filtertechnik GmbH page 9 of 9
CoMo-Control. Operating Manual. English (translation of original instructions) Documentation no.: a
Operating Manual English (translation of original instructions) Documentation no.: 3404207a Trademarks The trademarks of other companies are exclusively used for the products of those companies. Copyright
More informationFluidAqua Mobil FAM Economy Series
FluidAqua Mobil FAM Economy Series Description The FluidAqua Mobil FAM Economy series operates on the principle of vacuum dewatering to eliminate free and dissolved water as well as free and dissolved
More informationFluidAqua Mobil FAM 5
FluidAqua Mobil FAM 5 Description The FluidAqua Mobil FAM 5 is designed for dewatering, degassing and filtering hydraulic and lubrication fluids. It operates on the principle of vacuum dewatering to eliminate
More informationGLUE PUMPS. for Labelling Machines NEW MODEL ADVANTAGES: hoseproof IP66 programmable NFC-enabled
2015 GLUE PUMPS for Labelling Machines NEW MODEL 2015 ADVANTAGES: hoseproof IP66 programmable NFC-enabled Timmer GmbH Dieselstraße 37 D-48485 Neuenkirchen Tel.: +49 5973 9493-0 Fax: +49 5973 9493-90 www.timmer.de
More informationFluidAqua Mobil FAM 25/45/60/75/95 Series
FluidAqua Mobil FAM 5/45/60/75/95 Series Description The FluidAqua Mobil FAM 5/45/60/75/95 series operates on the principle of vacuum dewatering to eliminate free and dissolved water as well as free and
More informationFluidAqua Mobil FAM Economy Series
FluidAqua Mobil FAM Economy Series Description The FluidAqua Mobil FAM Economy series operates on the principle of vacuum dewatering to eliminate free and dissolved water as well as free and dissolved
More informationWet alarm valve stations
VdS Guidelines for water extinguishing systems VdS 2100-01en Requirements and test methods VdS 2100-01en : 2011-05 (02) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,
More informationUser s Manual MATRIX A MATRIX S MATRIX A. Filtro de aspiración Movil Matrix Tel.
Filtro de aspiración Movil Matrix 1000 User s Manual Filtering unit Tel. 976 359 352 MATRIX-1000-1-S MATRIX-1000-1-A MATRIX-1000-2-S MATRIX-1000-2-A email. albis@albis.net www.aspiraciondehumos.com KLIMAWENT
More informationOM-CP-Cryo-Temp Ultra Low Temperature Data Logger. Shop online at. omega.com For latest product manuals: omegamanual.
MADE IN Shop online at omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info OM-CP-Cryo-Temp Ultra Low Temperature Data Logger OM-CP-Cryo-Temp Product Notes Manual Start When the
More informationUser Manual. Single Diaphragm Dosing Pump SP-177. We set standards. Industriestrasse 56 FAX: FL-9491 Ruggell
We set standards User Manual Single Diaphragm Dosing Pump SP-177 MA-SP-177 en SAWATEC AG Tel: +423 37717 90 Industriestrasse 56 FAX:+423 37717 91 Postfach 514 info@sawatec.com FL-9491 Ruggell www.sawatec.com
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60068-2-21 Sixth edition 2006-06 Environmental testing Part 2-21: Tests Test U: Robustness of terminations and integral mounting devices IEC 2006 Copyright - all rights reserved
More informationHydraulic Reservoir Made of Polymer (TMP) or Steel (TMS)
Electric Drives and Controls Hydraulics inear Motion and Assembly Technologies Pneumatics Service Hydraulic Reservoir Made of Polymer (TMP) or Steel (TMS) RE 9571/0.11 1/1 Replaces: 0.09 Data sheet Hydraulic
More informationISO INTERNATIONAL STANDARD. Fire-fighting hoses Rubber and plastics suction hoses and hose assemblies
INTERNATIONAL STANDARD ISO 14557 First edition 2002-12-01 Fire-fighting hoses Rubber and plastics suction hoses and hose assemblies Tuyaux de lutte contre l incendie Tuyaux d aspiration et flexibles en
More informationInstallation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:
Installation and Operating instructions for C9900-U330-0010 battery pack Version: 2.0 Date: 2017-03-23 Table of contents Table of contents 1 Foreword 3 1.1 Notes on the Documentation 3 1.1.1 Liability
More informationIllustration shows item no Z Original operating manual. Operating manual. BlueMobil 60. Item no: Z-3285
Operating manual BlueMobil 60 Item no: Z-3285 Original operating manual Illustration shows item no Z-3285 Important Copyright It is essential that you read this manual thoroughly before the initial operation
More informationAir Cooler Industry OK-ELC 0-7
ir ooler Industry OK-EL 0-7 Symbol General The OK-EL air cooler series is designed specifically for hydraulic applications where high performance and efficiency are required and physical size must be minimized
More informationFA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.
INSTRUCTION MANUAL FA 400 Humidity measuring instruments with display and alarm for measurement of the pressure dew point and the atmospheric dew point in different applications: - compressed air plants
More informationSCHMIDT LED Measured Value Display MD Instructions for Use
SCHMIDT LED Measured Value Display MD 10.010 Instructions for Use Table of Contents 1 Important Information... 3 2 Application range... 4 3 Mounting instructions... 4 4 Electrical connection... 6 5 Signalizations...
More informationInstruction Manual Spray Booth SK 66
Instruction Manual Spray Booth SK 66 TABLE OF CONTENTS page 1. Important safety instructions... 3 1.1. General information... 3 1.2. Safety instructions... 3 1.3. Safety instructions for operation.....
More informationWHA 3000P Hot Air Station
WHA 3000P Hot Air Station Operating Instructions Version 2.3 Weller Tools GmbH Carl-Benz-Str. 2, 74354 Besigheim, Germany Tel: +49 (0) 7143 580-0, Fax: +49 (0) 7143 580-108 Table of contents Page 1. Description
More informationSub psi SPECIFICATIONS
SPECIFICATIONS PC Board Mountable Pressure Sensor 40 mv Output Typical Differential Pressures Metal Tube and Ceramic Barbed Ports Temperature Compensated The 1210 sub PSI is a temperature compensated,
More informationSOUTH AFRICAN NATIONAL STANDARD
ISBN 978-0-626-21896-6 Edition 1 SOUTH AFRICAN NATIONAL STANDARD Medical gas pipeline systems Part 1: Pipeline systems for compressed medical gases and vacuum This national standard is a modified adoption
More informationTail-end valve stations
VdS Guidelines for water extinguishing systems VdS 2100-15en Requirements and test methods VdS 2100-15en : 2011-05 (02) Publishing house: VdS Schadenverhütung GmbH Amsterdamer Str. 172-174 50735 Köln,
More informationTechnology for life. Unit heater LH
Technology for life. Unit heater 1 2 Contents Contents... Page Basic unit: casing, fan, motors... 4 Basic unit: heat exchanger... 5 Performance tables 25...6-7 Performance tables 40...8-9 Performance tables
More informationInstalling the assembly SIMATIC. Installing the assembly. Overview 1. Installing the assembly. Getting Started A5E
Overview 1 2 SIMATIC Getting Started 03/2013 A5E03973659-01 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as
More informationIn data sheets and application notes which still contain NXP or Philips Semiconductors references, use the references to Nexperia, as shown below.
Important notice Dear Customer, On 7 February 2017 the former NXP Standard Product business became a new company with the tradename Nexperia. Nexperia is an industry leading supplier of Discrete, Logic
More informationNautilus 4050 Heat Press. User Manual
Nautilus 4050 Heat Press User Manual Congratulations on the purchase of your Nautilus heat press! Please carefully read the operating manual to easily integrate your unit into your production environment.
More informationFlowJam Bulk Flow Detection
EN Operating Instructions FlowJam Bulk Flow Detection SWR engineering Messtechnik GmbH CONTENTS Page 1. Function............................................................................. 3 2. Safety..............................................................................
More informationStandard SPECIFICATIONS FEATURES APPLICATIONS
SPECIFICATIONS PC Board Mountable Pressure Sensor 0-50 mv Output Voltage Excitation Gage, Absolute, and Differential Temperature Compensated FEATURES Dual-in-Line Package 0ºC to 50ºC Compensated Temperature
More informationORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P
ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P Contents Description Data Sheet No. Page Overview P-1.50.001E 117-118 Technical Data SFI-plus P-1.50.002E-1, 2 119-120 Dimensions
More informationIllustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278
Illustration shows item no Z-3278 Operating manual BlueMobil eco Item no: Z-3278 Original operating manual Important Copyright It is essential that you read this manual thoroughly before the initial operation
More informationOperating Instructions!
Operating Instructions! 3 4 Oscillation MO 16.2 / MO 40 Example 3 4 MO 16.2 The unit has to be strictly used according to the instruction manual. Keep the unit away from children and from persons not instructed
More informationOperating and Maintenance Instructions
EATON Germany GmbH Werk Lohmar D-53797 Lohmar Operating and Maintenance Instructions WALFORM Machine Electronically controlled - Conforms to CE MEG-WF385X Status: Sept 2011 MEG-WF385X_Stand Sept 2011 SUITABILITY
More informationSýnishorn ISO 7183 INTERNATIONAL STANDARD. Compressed-air dryers Specifications and testing. Sécheurs à air comprimé Spécifications et essais
INTERNATIONAL STANDARD ISO 7183 Second edition 2007-12-15 Compressed-air dryers Specifications and testing Sécheurs à air comprimé Spécifications et essais Reference number ISO 7183:2007(E) ISO 2007 PDF
More informationWXHAP Washington Street Melrose, MA Phone Toll Free Visit us at
WXHAP 200 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com WXHAP 200 Operating Instructions LT LV EE SL SK HU PL CZ TR GR FI DK
More informationDP86 Constant Voltage with Fitting
SPECIFICATIONS 316L SS Wet/Wet Differential Low Pressure 0 100mV Output The DP86 constant voltage with fitting differential pressure sensor is a double-sided, media compatible, piezoresistive silicon pressure
More informationInstruction manual ISO-MIX Skid Mounted Pump Unit
Instruction manual ISO-MIX Skid Mounted Pump Unit ISO-MIX-FRONTPAGE.JPG OM SMPU-21-03, EN1 To the owner Dear owner, This Instruction Manual is your instant guide when dealing with your Alfa Laval equipment.
More informationProblem-solvers The Radiator Solution Range
Simplex Problem-solvers Problem-solvers The Radiator Solution Range I Height and depth compensation I Continuously swivelling connections I Reversal of supply and return flow I Quick and clean radiator
More informationInstallation and user guide Accumulator tanks
Installation and user guide Accumulator tanks Danfoss A/S - VUILB Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English language
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60115-9-1 First edition 2003-10 Fixed resistors for use in electronic equipment Part 9-1: Blank detail specification: Fixed surface mount resistor networks with individually
More informationISO INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 13937-3 First edition 2000-04-01 Textiles Tear properties of fabrics Part 3: Determination of tear force of wing-shaped test specimens (Single tear method) Textiles Propriétés
More informationISO INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 13938-1 First edition 1999-08-01 Textiles Bursting properties of fabrics Part 1: Hydraulic method for determination of bursting strength and bursting distension Textiles Propriétés
More information1/24/01 SYLVANIA Process Heat FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.
HOT AIR TOOL 3500 068462, 068463, 068464, 070878, 071383 FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE. Description! Compact, efficient heater with stainless steel housing and
More informationISO 2896 INTERNATIONAL STANDARD. Rigid cellular plastics Determination of water absorption
INTERNATIONAL STANDARD ISO 2896 Third edition 2001-07-01 Rigid cellular plastics Determination of water absorption Plastiques alvéolaires rigides Détermination de l'absorption d'eau Reference number ISO
More informationMBWeich 100. Operating manual. 1. Introduction. 2. Use
Soaking Unit MBWeich 100 Meier-Brakenberg GmbH & Co. KG Brakenberg 29 32699 Extertal Germany Tel.: +49-5262/993 99-0 Fax: +49-5262/993 99-3 E-mail: info@meier-brakenberg.de Operating manual 1. Introduction
More informationFOR ENGCON STONE AND SCRAP HANDLING GRAB SK05ST-SK30ST THE WIDEST RANGE ON THE MARKET
Instruction manual Stone and scrap handling grab SK05ST-SK30ST English FOR ENGCON STONE AND SCRAP HANDLING GRAB SK05ST-SK30ST THE WIDEST RANGE ON THE MARKET Increase your excavator s efficiency and precision
More informationChiller System RFCS. Application Field. Symbol. General. Product Features
Chiller System RFCS Symbol Cooling circuit Refrigeration circuit Safety and regulation unit Condenser Application Field l Machine tools l Presses l Milling machines l Welding systems Whether integrated
More informationAquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes
Thermostatic valve with adjustable temperature control range Technical information Tender specification: Oventrop thermostatic valve Aquastrom T plus with presetting for circulation pipes. Thermal control
More informationJASOPELS ROTATING FLESHING MACHINE 1-BEAM
USER MANUAL JASOPELS ROTATING FLESHING MACHINE 1-BEAM ITEM NO. 32200067 Our quality Your choice 2 www.jasopels.com TABLE OF CONTENTS About this document... 3 Declaration of Conformity... 6 Safety... 6
More informationISO INTERNATIONAL STANDARD. Non-destructive testing Penetrant testing Part 2: Testing of penetrant materials
INTERNATIONAL STANDARD ISO 3452-2 First edition 2000-04-01 Non-destructive testing Penetrant testing Part 2: Testing of penetrant materials Essais non destructifs Examen par ressuage Partie 2: Essais des
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60384-22-1 First edition 2004-06 Fixed capacitors for use in electronic equipment Part 22-1: Blank detail specification: Fixed surface mount multilayer capacitors of ceramic
More informationIsolated Thermocouple Module
User Manual for the HE693THM665, HE693THM666, HE693THM667, HE693THM668 Isolated Thermocouple Module Twelfth Edition 19 April 2004 PREFACE 19 APR 2004 PAGE 3 PREFACE This manual explains how to use the
More informationAEROSOL SPECTROMETERS
AEROSOL SPECTROMETERS Top resolution, the best classification accuracy, coincidence detection and correction of the individual signal 1 APPLICATIONS Research and development, environmental measurements
More informationValves, controls + systems. Regucor WHS Energy storage centre. Innovation + Quality. Product range. v o. Awards: i y. n n
Valves, controls + systems Innovation + Quality Energy storage centre Product range ed v o r p m i y c n n for a y efficie g ener Awards: Energy storage centre Heating systems with regenerative energy
More informationOperating Instruction Precipitation Sensors (15189) + (15189 HL)
Features Precipitation Sensor for automatic weather stations Exchangeable, weighing tipping bucket system according to Joss- Tognini 2 cm³ (2g water) tipping bucket for precise precipitation measuring
More informationInstruction manual. Water treatment Boiler system D 30 L
Water treatment Boiler system D 30 L Manufacturer: deconta GmbH Im Geer 20, D - 46419 Isselburg Description / Type No.: Water treatment / D 30L /... Serial No.:... Table of contents 1 Introduction 3 2
More informationDifferential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50
Differential Pressure and Flow Meter Media 5 Indicator 160 Ø PN 50 Application Transmitter for measuring and indicating the differential pressure or measured variables derived from it Suitable for gases
More informationFACTORY AUTOMATION. Instruction Manual NBB20-L2-E2B-C-V1 NBN40-L2-E2B-C-V1 Inductive Sensor
FACTORY AUTOMATION Instruction Manual NBB20-L2-E2B-C-V1 NBN40-L2-E2B-C-V1 Inductive Sensor Part. No. 202415 / DOCT-1310 / 05. june 2007 1 Sensor description...............................................
More informationLight oil / kerosene burner
Installation, use and maintenance instructions Light oil / kerosene burner One stage operation CODE MODEL TYPE 374445 G5 444T50 290238 (5) - 05/20 TECHNICAL DATA Thermal power output 28 60 kw 2.3 5 kg/h
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60364-6 First edition 2006-02 Low-voltage electrical installations Part 6: Verification This English-language version is derived from the original bilingual publication by leaving
More informationExtended Coverage Sidewall Sprinklers
VdS Guidelines for water extinguishing systems VdS 2100-28en Extended Coverage Sidewall Sprinklers Requirements and Test Methods VdS 2100-28en : 2011-05 (01) Publishing house: VdS Schadenverhütung GmbH
More informationSurgical Suction: Silent and powerful!
ATMOS C 451 & ATMOS C 361 The success story continues! Surgical Suction: Silent and powerful! TOP PERFORMANCE FAIR PRICE If you don t go forward, you go backwards 2008 ATMOS set already a new standard
More informationISO INTERNATIONAL STANDARD. Testing of valves Fire type-testing requirements. Essais des appareils de robinetterie Exigences de l'essai au feu
INTERNATIONAL STANDARD ISO 10497 Third edition 2010-02-15 Testing of valves Fire type-testing requirements Essais des appareils de robinetterie Exigences de l'essai au feu Reference number ISO 10497:2010(E)
More informationNew Product Introductions 2011
New Product Introductions 2011 New Product Introductions MAFH-E 15gpm Dewatering Unit Portable Filtration Systems OFS Filtration Station OFCS-OFCD Filter Carts OF7 Hand Held Filters High viscosity version
More informationRegulux. Radiator lockshield with drain-off facility. To be precise.
Radiator lockshield with drain-off facility To be precise. Description Assembly Regulux Closing cap Thrust piece HEIMEIER radiator lockshield for shutting off, presetting, draining off and filling. Separate
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 6772 Third edition 2012-10-01 Aerospace Fluid systems Impulse testing of hydraulic hose, tubing and fitting assemblies Aéronautique et espace Systèmes de fluides Essai d impulsion
More information82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated
SPECIFICATIONS 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated The 82 constant voltage is a 19 mm small profile, media compatible, piezoresistive
More informationOK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.
INSTALLATION, OPERATION & SERVICE MANUAL FOR COOLER TYPES OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN. 1. Introduction This manual is a guide for the installation, maintenance
More informationInstallation instructions
2Power storage tank Installation instructions This installation construction contains important advice for handling, installing and starting up a 2Power solar plant. Read these advice carefully before
More informationOperating manual GTL 369 GTL 369M GTL 389 GTL 389M. Temperature probe. Please keep the manual for future use.
Operating manual Temperature probe GTL 369 GTL 369M GTL 389 GTL 389M Please keep the manual for future use. L02.0.3X.6C-01 GREISINGER electronic GmbH Hans-Sachs-Str. 26 93128 Regenstauf Germany Fon +49(0)9402-9383-0
More informationROTARY SPRAY HEADS CATALOGUE
ROTARY SPRAY HEADS CATALOGUE Via G.Pastore 7/A - 43058 Sorbolo (PR) ITALY Tel. +39.0521.698578 - Fax +39.0521.030554 www.caggiatiinox.com - info@caggiatiinox.com Rotary head series 64 Construction: The
More informationVarioAir Medical Suction Solutions Consumables and Accessories
VarioAir Medical Suction Solutions Consumables and Accessories Whether in the operating room or in the intensive care unit, when it comes to suction, you need high-performance, reliable devices that are
More informationV2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE
V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE Application Thermostatic flowshare valves control the output of radiators in vertical one-pipe heating systems. Heating water not required
More informationFACTORY AUTOMATION. INSTRUCTION MANUAL Interrogation data set for welding tongs NBN3-FXA-3E2-2V1
FACTORY AUTOMATION INSTRUCTION MANUAL Interrogation data set for welding tongs NBN3-FXA-3E2-2V1 194110 / DOCT-0976 / 23.06.2006 1 System overview............................................. 5 2 Programming
More informationP14 Rapid Capacitive Humidity Sensor For weather balloons and radio sondes
H2 H W P14 Rapid Benefits & Characteristics Ultra fast response time Condensation resistant High humidity stability Wide temperature range Temperature shock resistant Fast recovery time Customer specific
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60939-2-2 First edition 2004-11 Complete filter units for radio interference suppression Part 2-2: Blank detail specification Passive filter units for electromagnetic interference
More informationE-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems
E-Z Valve Thermostatic valves with radiator connection systems For single and two-pipe heating systems IMI HEIMEIER / Thermostatic heads and Radiator valves / E-Z Valve E-Z Valve E-Z Valve with immersion
More informationDOG2 MEMS SERIES USB INCLINOMETER
1 DOG2-USB_1630-21559-0018-E-0118 DOG2 MEMS SERIES USB INCLINOMETER SPECIFICATIONS Dual axis inclinometer Measurement range ±90 High resolution Good accuracy Fast response time Easy to use software FEATURES
More informationFlowJam S Ex. Bulk Flow Detection. Operating Instructions. SWR engineering Messtechnik GmbH
EN FlowJam S Ex Operating Instructions Bulk Flow Detection SWR engineering Messtechnik GmbH CONTENTS Page 1. Function.......................................................................... 3 2. Safety..............................................................................
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61784-5-14 Edition 1.0 2010-07 colour inside Industrial communication networks Profiles Part 5-14: Installation of fieldbuses Installation profiles for CPF 14 IEC 61784-5-14:2010(E)
More informationMagnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions
Magnetic-Inductive Flow Velocity Sensor PIT Installation and Operating Instructions Table of contents 1 IDENTIFICATION... 3 1.1 Manufacturer/supplier... 3 1.2 Product type... 3 1.3 Product name... 3 1.4
More informationV2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS
W GE R MAN Y W GE R MAN Y V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS Design Angle left Straight W GE R MAN Y Angle right The Therafix
More informationM7100 Pressure Transducer
SPECIFICATIONS Performance standard on and off highway engine and vehicle OEMs Rugged for heavy equipment and outdoor use Designed specifically for high volume applications Stainless steel wetted surfaces
More informationInstruction Manual July 2008 TS-2 TEMPERATURE SENSOR
Instruction Manual July 2008 TS-2 TEMPERATURE SENSOR Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected
More informationInstallation and Operation Instructions K36E Modular Heating Circuit - DN 25 Boiler charging set
PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 Email: info@paw.eu, Web: www.paw.eu Installation and Operation Instructions K36E Modular Heating
More informationHEGA-Medical Product list V7.0
HEGA-Medical Product list V7.0 State: 01.08.2016 Rinsing Guns without hose and attachments Dina Rinsing Gun with nozzle and spout 6000 Nova Rinsing Gun with nozzle and spout 7000 Dina Rinsing Gun, open
More informationMK-660 tile saw OWNER'S MANUAL PARTS LIST & OPERATING INSTRUCTIONS
www.mkdiamond.com MK-660 tile saw OWNER'S MANUAL PARTS LIST & OPERATING INSTRUCTIONS Revision 06 03.207 Manual Part# 5346 Caution: Read all safety and operating instructions before using this equipment.
More informationSilent TS. Nr / Ideas for dental technology / A. Made in Germany
Silent TS Nr. 2921-0050 / 2921-1050 21-9191 30102012 / A Made in Germany Ideas for dental technology 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Silent TS Nr. 2921-0050
More informationTTV 4500 / TTV 4500 HP / TTV 7000
TTV 4500 / TTV 4500 HP / TTV 7000 EN OPERATING MANUAL AXIAL FAN TRT-BA-TTV4500-4500HP-7000-TC-003-EN Table of contents The current version of the operating manual can be found at: Notes regarding the operating
More informationFSW300 Series Flow Switch
. FSW300 Series Flow Switch - 2 - Series FSW300 Series FSW300 Table of contents page 0 About this operating manual... 4 1 Device description... 5 1.1 Intended use... 5 1.1.1 Reed contact - Switching of
More information85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated
SPECIFICATIONS 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature The 85 compensated is a small profile, media compatible, piezoresistive silicon pressure sensor packaged
More informationGMA Panels with double busbar
L1 L2 L3 GAS-INSULATED SWITCHGEAR >> GMA Panels with double busbar Operating Instructions No. AGS 532 521-01 Edition 09/07 (Supplement to Operating Instructions AGS 531 521-01) Technical Instructions AREVA
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61169-42 Edition 1.0 2013-01 colour inside Radio-frequency connectors Part 42: Sectional specification for CQN series quick lock RF coaxial connectors IEC 61169-42:2013(E) THIS
More informationNEPTUN I Sole cleaning unit Art.-No.:
Assembly and operating instructions Please read the instruction carefully before assembling and putting into operation. Keep instruction for future reference. Contents. General 2. Function 3. Installation
More information86A SPECIFICATIONS. 316L SS Pressure Sensor Small Profile V High Level Output Gage, Absolute ASIC Calibrated
(Image displays Absolute type) 86A SPECIFICATIONS 316L SS Pressure Sensor Small Profile 0.5-4.5V High Level Output Gage, Absolute ASIC Calibrated The 86A is a small profile, media compatible, piezoresistive
More information154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.
SPECIFICATIONS Low Cost 316L Stainless Steel or Titanium 19mm Diameter Package 0-100mV Output Gage and Absolute Wide Compensated Temperature Range The 154BC is a 19mm small profile, media compatible, piezoresistive
More informationISO 7183 INTERNATIONAL STANDARD. Compressed-air dryers Specifications and testing. Sécheurs à air comprimé Spécifications et essais
INTERNATIONAL STANDARD ISO 7183 Second edition 2007-12-15 Compressed-air dryers Specifications and testing Sécheurs à air comprimé Spécifications et essais Reference number ISO 7183:2007(E) ISO 2007 PDF
More informationInstallation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A)
EN Installation manual surface mounting plugs and socket outlets, panel 60003214 Issue 04.2016 2016-04-01 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3
More information51AKS I S O OWNER S MANUAL
LLOYD'S REGISTER QUALITY ASSURANCE 51AKS I S O 9 00 1 OWNER S MANUAL This manual applies to the following models Stand-alone Split 51AKS 085--- 51AKS 010--- 51AKS 185--- 51AKS 013--- 51AKS 113--- 51AKS
More informationInstruction Manual, Toftejorg Rotary Spray Heads Toftejorg MultiMidget, Toftejorg MultiMagnum
Instruction Manual, Toftejorg Rotary Spray Heads Covering Standard version ESE02746EN Date of issue: April 29, 2014 First published: April 29, 2014 Original manual Contents Contents... 1 Toftejorg Rotary
More information