Solar Controller SUNGO SL

Size: px
Start display at page:

Download "Solar Controller SUNGO SL"

Transcription

1 OPEATING INSTUCTIONS, Version SW03/3.00/ HW3.0 Solar Controller SUNGO SL Wagner& Co Figure Solar Controller SUNGO SL. The benefits at a glance Large illuminated display to indicate temperature, balance values and system status with clearly visible symbols for easy readability. Easy and safe operation via four buttons for vertical and horizontal scrolling through the menus. Extensive diagnostics for monitoring system functions, eg. sensor cutoff and monitoring of temperature difference T too high Integrated security functions such as collector cooling, storage tank cooling, system protection and vacuum tube collector function. Solar charging of and tank systems Choice of thermostat function or return temperature increase Balance/reset values 5 temperature inputs PT000 output, speed-controlled The sensor T5 (solar return) and an external volume measuring device provide energy measurements in kwh. NEW now also SECUSOL system ready! Contents. Technical Description.... General Safety Guidelines Installer s Qualifications Operating equirements Installation and Operating Information Installation Installation of the Housing Connecting Wires Operation Display and Buttons Information Menu Settings Menu Manual Operation Menu Special Functions Menu Service System Messages Service Sensor Control Application Examples Standard Single Tank System Standard Dual Tank System SECUSOL System... Solar Thermal / Solar Circuit EN-SUNGO-SL-BA-0804-P300

2 . Technical Description Solar Controller SUNGO SL Material Dimensions (LxHxWinmm) 00% recyclable ABS-housing for wall mounting 73x38x5 Protection type IP40 according to VDE 0470 ate of radio interference N according to VDE 0875 Operating voltage Diameter of cable max. for 30 V connections Temperature sensor / Temperature range Sensor load Test voltage Switching voltage Output parameters of switches Internal mains protection Operating temperature (internal) / storage temperature Weight 30 Volt AC; 50 Hz; -0% to +5%.5 mm² unifilar or finely stranded Pt000; 000 W at 0 C; ange: -30 C to +5 C The cable of the sensor must be installed with no tension. The sensor must not be loaded mechanically when the temperature of the collector is more than 60 C. 4 kv min according to VDE Volt AC A / ca. 30 VA for cos ϕ = for each output Microfuse 5x0mm; A/T 0 to +50 C / -0 to +65 C ca. 360 g Solar Charging The solar circuit pump is switched on and off by means of a temperature difference control. The sensors T (collector) und T (tank, bottom) are required as control elements. The on/off conditions and the temperature limitation can be variably set in the settings menu. Note: The temperature limitation always affects sensor T (tank, bottom). Speed Control The solar circuit pump can be controlled via speed control (in this case impulse packet control). This means that individual sine half-waves in the alternate current are switched on or off depending on the temperature difference. Therefore the speed can be altered within a range of 30-00% which results in longer system run times. The minimum speed can be custom set. Sensor T3 (tank, top) Sensor T3 (tank, top) has different functions. By default it is the measuring sensor for the top of the tank. In that case it has no switch function and is not monitored by the diagnostics system. With the return temperature increase function activated it functions as a hot sensor (source). With the thermostat heating with additional sensor function activated it functions as an additional sensor. In both cases this sensor is used in the hotareaofthetankandaffectsswitchingoutputa. If used in this way the sensor function is monitored as normal by the diagnostics system. Balance Values In addition to the actual values of the sensors T (collector) and T (tank, bottom) the display also shows balance values which represent the smallest and biggest temperature values for each sensor. After reset the actual temperature value is displayed. Manual Operation Allows switching inputs and outputs on or off manually. On exiting the manual operation menu, the software returns to automatic operation. The manual operation menu can be used for a maximum of 8 hours.after that the software automatically switches back to automatic operation and to the information menu. Manual Lag Function In order to check the temperature values in the information menu even when the outputs are set manually, a time lag has to be selected in the manual lag function in the manual operation menu. On exiting the manual operation menu, this time span passes once and then is set back to zero. In this mode a blinking symbol for the manual operation is shown in the information menu. Collector Cooling The tank is loaded up to the preset temperature limitation which affects sensor T (tank, bottom). If the preset temperature limitation is exceeded output A (solar circuit pump) switches off. If the temperature of T (collector) then rises above the selectable standard value of 0 C the solar circuit pump is switched on in order to cool the collector. It switches off again when the temperature at the collector sensor has decreased by 0 K. This type of intermittent operation of the solar circuit pump means that the collector is never or only rarely in an idle state. If the preset tank temperature limitation is exceeded by 5 K the collector cooling function is suppressed. The system shuts down completely. Storage Tank Cooling Storage Tank Cooling means that if necessary the tank temperature can be reduced down to a preset lowest switching off value (setting for vacations). When the collector cooling function is activated storage tank cooling will also become active. In order for storage tank cooling to become active the following 3 conditions must be met:. Temperature T (tank, bottom) must be higher than or equal to the preset tank temperature limitation plus K.. Temperature T (tank, bottom) must be higher than the preset switching off value for storage tank cooling. 3. Temperature T (collector) must be lower than temperature T (tank, bottom) minus 0 K. In order for storage tank cooling to switch off one of the following conditions must be met:. Temperature T (tank, bottom) is lower than the switching off value for storage tank cooling.. Temperature T (collector) must be higher than temperature T (tank, bottom) minus K. EN-SUNGO-SL-BA-0804-P300

3 Vacuum Tube Collector Function The vacuum tube collector function allows operation of the solar heating system even if sensor T (collector) is installed in the connecting pipe of the collector. If the temperature increase at sensor T exceeds the preset switching on value for the collector temperature increase (standard: K) the solar circuit pump is switched on for the duration of a preset lag time (standard: 5 s). During this time the switching on difference and the solar charge between sensor T (collector) and sensor T (tank, bottom) has to be activated, otherwise the solar circuit pump will switch off again. The rise in temperature at sensor T (collector) is measured again immediately after the last runtime of the pump. System Messages The system messages for interrupted or shorted-out sensors are represented by symbols on the display. For better recognition of the system messages the display illumination switches on and off every second as long as the error prevails and no key entry is made. Triac The Triac is an electronic on/off switch for the 30 V outputs of the SUNGO Controller. Function: A triac switch consists of diodes which can be switched anti-parallel (= antiparallel thyristors). The thyristors switch through the positive or negative sine halfwave as long as a switching on difference exists. The triac switch switches off when the temperature falls below the switching-off difference. System Protection In order to protect the system components (solar circuit pump, or 3 way valves etc.) in the solar heating circuit from extremely high temperatures the solar charge is stopped completely if a temperature limit at the collector sensor is exceeded, even if this was permitted on account of a temperature difference between sensor T (collector) and sensor T (tank, bottom). The standard temperature value for activating the system protection function is 35 C. However, this value can be variably set within a range of 5 to 00 C. T4 is higher than the switch-on level plus the switch-off difference. With the heating option an additional sensor T3 can be activated. If this is the case A is only switched on if temperature T3 is higher than the switching on level plus the switching off difference plus the additional difference for T3. With the cooling option activated output A switches on if the current temperature T4 falls below the preset switch level. Output A switches off if the current temperature T4 is lower than the switch level minus the switching off difference. There are 3 independent time windows available for the thermostat. If no time window is activated time window has to be set to 0:00 and 3:59. eturn Flow Boost This is a freely adjustable temperature difference for simple heating support which leads the heating return-flow T4 (drain) to the heating boiler, either directly or via the solar tank, depending on the preset temperature difference to the tank sensor T3 (source),by switching the 3 way valve on output A. Note: In addition to the switching phase (black) on output A, the switching head also requires a constant phase (brown). SECUSOL Function The solar heating system is operated on a drain back principle. This means if the solar circuit pump is not activated there is no solar fluid in the collectors and risers. See SECUSOL instructions for further details. Measuring the Yield For measurements of the solar yield in kwh. The heat yield is measured with a volume measuring device, an additional sensor T5 (return) and the existing sensor T (collector). Dual tank operation The SUNGO SL is capable of controlling a dual tank system by using output A for switching between tanks with the help of a 3 way valve. Change the menu item 0 to0 in order to control a dual tank system. Note: If the dual tank option is selected menu item 0 can no longer be activated. Preference The SUNGO SL always uses tank as a preference for the dual tank option. This cannot be changed. Thermostat The thermostat function for switching on can be set at a range between 0 to 30 C with a variable difference between to 40 K for switching off. Choose between the options heating and cooling. With the heating option activated output A switches on if the current temperature T4 falls below the preset switching on level. Output A switches off if the current temperature EN-SUNGO-SL-BA-0804-P300 3

4 . General Safety Guidelines The following safety advice is designed to protect you from dangers that can arise from improper handling of devices, whether intentional or otherwise. A distinction is made between general advice presented here and specific advice presented throughout the guidelines. DANGE for danger to the person Improper electrical installation of the device can lead to potentially fatal electric shocks as well as other health hazards. CAUTION for danger to property This symbol indicates dangers that can result in damage to the components or the function of the control. NOTE for additional information This symbol indicates practical advice and tricks of the trade which will be useful for installing and operating the control.. Installer s Qualifications Setting up and commissioning of the SUNGO SL must be carried out by a qualified installer. All national and local safety regulations need to be complied with. Please note that in case of a complaint the guarantee is only valid if correct commissioning has been certified in a commissioning report.. Operating equirements Application Controlling solar thermal systems through the selection of applicable control patterns and additional functions to adapt the control for the required operation of the hydraulic system. The control must only be operated in dry rooms. The control can be integrated into the solar circulation unit or mounted on the wall. Limitations of use If used in a non-solar thermal application the functionality of the control has to be checked before commissioning. If in doubt contact the control service of Wagner & Co. If these operating requirements are not observed any claims under the warranty will not be accepted..3 Installation and Operating Information Any installation and wiring work has to be carried out in an idle state as during operation the voltage on the outside of the triacs is 30 V. Mains power must be connected to the control from outside the solar station via an external ON/OFF Switch. This is also required to activate the special functions menu through switching the mains power ON/OFF. Operating temperatures above 50 C are not permitted for the control. LCD display panels are designed in such a way that a specific reading position is required. When installing the control, be careful to place the display so that it is at eye level or slightly higher. This way you can ensure optimal display contrast. The base of the control is divided into a safety low voltage section and a 30 V section by a crosspiece. Make sure that you do not confuse these sections during the installation process. The default operating mode is the automatic mode. Manual operation is used only for functional testing of the different hydraulic components (pump, /3 way valve). In this operating mode maximum temperatures or sensor functions are not monitored. Do not operate the system if the control,the wiring or the connected 30 V mains are visibly damaged. The control is fitted with a mains microfuse. Collectors and hydraulic pipework can get extremely hot during sunny periods. There is a risk of scalding when fitting the collector temperature sensor. 3. Installation 3. Installation of the case Opening the case No tools are required to open the control case. The lid folds over on top of the lower half. You can dislodge and lift up the lid by pulling gently on the side clips. When fully opened the lid will not move so that you can take care of mounting and wiring comfortably. Wall mounting Use the supplied drilling template to drill the fixing holes for the controller. Mount the control to the wall. Do not overtighten the screws to avoid damage to the lower part of the housing. 4 EN-SUNGO-SL-BA-0804-P300

5 Installation in the Solar Circulation Unit With the screws mount the SUNGO SL on the wall holder of the solar circulation unit. Break out the cable feeds which are located on the base housing next to the crosspiece. Strip the 30 V cables in a way that the insulated single cables start directly at the feed to the base housing. Hold cable clamps steady when screwing tight in order to minimise pressure on the circuit board. There is a danger of the terminals to be torn off! Finally connect to mains power. When the control is switched on the voltage on the triacs housing is 30 V AC. 3. Connecting Wires Layout of the SUNGO SL Connections All electrical connections are made to the circuit board at the bottom of the control. The sensor connections (safety low voltage) are located on the right hand side and the 30 V mains connections and the switching outputs A and A on the left hand side. General connection rules If flexible wires are used and the control is wall mounted, a strain relief must be fixed within or outside of the control. In this case you must crimp the wire ends. If required PG9 screws can be fixed at the feed-throughs in case of wall mounting. 30 V mains connection Mains power is connected from outside the control via an ON/OFF Switch. This switch is not required if mains power is with a protective plug to a socket. The control is suitable for mains operation at approx. 30 V/50 Hz. All earth wires are connected to the PE terminals. The neutral terminals (N) are connected electrically. Switching output A is a 30 V normally open contact which is activated via speed-control. Switching output A is purely a normally open contact. Connecting the temperature sensors The wires of the temperature sensors can be extended: Up to 5 m length, x 0.5 mm² cable can be used, beyond 5 m and up to 50 m x 0.75 mm² is necessary. Shielded cables should be used for long connections to the collector. Do not connect the shielding at the sensor end, just trim and isolate. The polarity of the temperature sensors is irrelevant and they can be connected either way. The sensor wires must be installed separately from 30 V mains cables. Lightning Protector Module The SUNGO SL is fitted with spike protection on all sensor terminals. Generally, further protection of the tank sensors is not required. Sensor T (collector) should be fitted with the sensor connection box SP with an overvoltage protection. ControllerIC Plug for Display FUSE 5X0 Triac PE-PE A A L Trafo T T T3 T4 T5 M M M M M T7 M PE-PE N N N Potential Earth Switching output Solar circuit pump Mains L Collector sensor, T Tank sensor, bottom, T Tank sensor, top / Additional thermostat sensor / return flow boost (source) Thermostat / return flow boost (sink), T4 Heat meter (yield), return flow sensor, T5 Volume flow meter, T7 Figure SUNGO SL circuit board components. EN-SUNGO-SL-BA-0804-P300 5

6 4. Operation 4. Display and Buttons Settings menu Information menu Manual operation menu Special functions menu Temperature difference Numerical display for temp. or sensor errors Collector temperature Symbol for reset value Tank temp., bottom Pump ON/ Pump OFF Output A Output A dt min max start stop KWh C % x! ok? Balance or start / stop values Units Tank temp., top/ thermostat additional sensor Temperature thermostat/ return flow boost (sink) Time slot thermostat Tank temp., mid section/ return flow boost (source) Confirm and save symbol System error 6 EN-SUNGO-SL-BA-0804-P300

7 Horizontal operating level Vertical operating level Settings menu as an example Switching off diff. T3 - T4, return temperature increase Switching on diff. T3 - T4, return temperature increase Min temp. level, return temperature increase Temp. limitation, return temperature increase Stop time window 3, thermostat Start time window 3, thermostat Stop time window, thermostat Start time window, xx thermostat Stop time window, thermostat Start time window, thermostat dt min dt max T min T max stop start stop start stop start 3 3 I I 4 4 T max dt max dt min T min dt d min d max T start dt dt Temperature limitation tank, bottom Switching on difference T - T, solar Switching off difference T - T, solar Min. temp. source Design temp. diff. speed control, solar Min. speed, solar circuit pump Max. speed solar circuit pump (SECUSOL) Charge time solar heating system (SECUSOL) Current time Switching on temperature, thermostat Switching off temperature, thermostat Difference additional sensor T3, thermostat Set values Activate value Increase value Decrease value Activate save function Save value EN-SUNGO-SL-BA-0804-P300 7

8 4. Information Menu Information menu Menu item Description Display min max min max h h min max h h Collector temperature; Current value C Collector temperature; Balance; minimum, resettable C Collector temperature; Balance; maximum, resettable C Tank temperature, bottom; Current value C Tank temperature, bottom; Balance; minimum, resettable C Tank temperature, bottom; Balance; maximum, resettable C Tank temperature, top; Current value C Operating hours, total; Balance h operating hours since last reset; Balance, display, resettable h Tank temperature or, bottom; (if tank system is selected) Tank temperature or, bottom; (if tank system is selected) Tank temperature or, bottom; (if tank system is selected) Operating hours tank or, total; (if tank system is selected) operating hours tank or since last reset; (if tank system is selected) Current value Balance; minimum, resettable Balance; maximum, resettable Balance Balance; display, resettable C C C h h kwh Thermostat or return temperature increase (drain); Current value C Heat counter, return; (flow value corresponds to collector temperature) Current value Heat counter, total yield; Balance kwh C kwh heat counter since last reset; Balance, display, resettable kwh Heat counter tank or, total; Balance kwh kwh heat counter, tank or kwh since last reset; Balance, display, resettable kwh Pump symbol idle: Operating symbol Temperature difference (collector, tank) is smaller than required to activate the solar circuit pump. The solar circuit pump is off. otating pump symbol: Temperature difference (collector, tank) is sufficient to activate the solar circuit pump. The solar circuit pump is running. Operating symbol 8 EN-SUNGO-SL-BA-0804-P300

9 4.3 Settings Menu Settings menu Menu item Description ange Default setting T max dt max dt min T min T max dt max dt min dt d min d max T start Temperature limitation tank, bottom 5 90 C 85 C Switching on difference between collector and tank 3 40 K 5 K Switching off difference between collector and tank 35 K 3 K Min. temp. above which the switching difference is analyzed 5 90 C 0 C Temperature limitation tank or, bottom 5 90 C 85 C Switching on difference between collector and tank or 3 40 K 0 K Switching off difference between collector and tank or 35 K 3 K Design temperature difference the speed control adjusts to 50 K 0 K Minimum speed of the solar circuit pump 0% increments Maximum speed of the solar circuit pump Only with SECUSOL! Charge time (s) of the solar heating system with speed 00%; in 0 s increments Only with SECUSOL! 30 00% 30% 30 00% 00% s 60 s Set current time (keep button pressed for faster run-through) 0:00-3:59 0:00 dt dt Switching on temperature thermostat 0 30 C 30 C Switching off difference thermostat 40K 5K Additional sensor difference for tank, top, can be selected in heating function. 3 0K 0K start stop start stop start stop I I 3 3 Start time slot, thermostat 0:00-3:59 0:00 Stop time slot, thermostat 0:00-3:59 3:59 Start time slot, thermostat 0:00-3:59 0:00 Stop time slot, thermostat 0:00-3:59 0:00 Start time slot 3, thermostat 0:00-3:59 0:00 Stop time slot 3, thermostat 0:00-3:59 0:00 T max T min dt max dt min Temperature limitation return temperature increase 5 90 C 85 C Minimum temperature from which the switching on difference is read 5 90 C 0 C Switching on difference return temperature increase between temperature measure location T3 and T4 3 40K 4K Switching off difference return temperature increase between temperature measure location T3 and T4 35K K Only available if heating or cooling thermostat is used. Only available if return temperature increase is used. EN-SUNGO-SL-BA-0804-P300 9

10 4.4 Manual Operation Menu Manual operation menu Menu item Description ange Default setting Off = 0/On = Switching the solar circuit pump on or off manually (A) Off = 0/On = Switching output A on or off manually (LA or thermostat) T stop Activation of manual operation lag time in automatic mode min 0 min 4.5 Special Functions Menu During the first minute after switching on the control activate the special functions menu by selecting it so that parameters can be altered.the menu stays active for minute after exiting it. On exiting the menu the parameters can only be viewed but not changed again.place the control in the idle position once again if you need to alter any functions. Special functions menu Menu item Application Description ange Default setting 0 System choice 0 : Standard single tank system 0 : Standard dual tank system 0 3: SECUSOL system (see SECUSOL instructions for further info) 3 System Protection Off = 0/On = Activation of system protection. Cannot be activated with SECUSOL! 0or System protection start temperature 5 00 C 35 C 3 Collector Cooling Off = 0/On = Activation of collector cooling. Cannot be activated with SECUSOL! 0or 4 Collector cooling start temperature C 0 C 5 Storage tank Cooling Off = 0/On = Activation of tank cooling. Only possible with collector cooling. Cannot be activated with SECUSOL! 0or 0 6 Switching off temperature C 60 C 7 Off = 0/On = Activation of yield measurement 0or Measuring the Yield Frost protection type 8-: DC0 for standard systems 8-: DC40 for vacuum tube collectors (ready mix) Glycol fraction in %. 0% = No Glycol (pure water) 00% = Pure Glycol (no water) Note: Glycol fraction for solar circuit can only be selected with DC0! or 0 00% 40% 0 Function selection 0 0: Additional functions off 0 : Thermostat, heating 0 : Thermostat, heating with additional sensor T3 (tank, top) 0 3: Thermostat, cooling 0 4: return temperature increase Off = 0/On = 0or 0 Activation of vacuum tube collector function Vacuum Tube collector function un time of solar circuit pump from reaching the switching on value 60 s 5 s 3 Switching on value for temperature increase at sensor T (collector) K.0 K The special functions menus should only be edited by expert personnel. Incorrect settings may adversely affect the solar heating system. 0 EN-SUNGO-SL-BA-0804-P300

11 4.6 Service System Messages System information with display Display Description emedy C C! Blinking! Blinking! Blinking System messages All system messages are displayed with a blinking caution symbol. In case of sensor errors the sensor in question is also marked with short circuit or interruption symbol. Interruption The sensor on the display or the pipe is interrupted. Short circuit There is a short circuit on the sensor on the display, the cable or the output on the control. Test the resistance value of the sensors and compare with the tables. Check all connections to the sensor.! Blinking dt too high A value of 0 K is added to the switch-on difference between T and T. The message is displayed if after 30 minutes the total difference has not been reduced. Check wiring to the pump Check system for air and vent if required Check sensors and sensor wiring, replace sensors if required 4.7 Service Sensor Control esistance values for Pt000 sensors in relation to the temperature -0 C 0 C 0 C 0 C 30 C 40 C 50 C 60 C 70 C 80 C 90 C 00 C 0 C 96 Ω 000 Ω 039 Ω 078 Ω 7 Ω 55 Ω 94 Ω 3 Ω 7 Ω 309 Ω 347 Ω 385 Ω 43 Ω The working condition of the sensor can be checked with this table and an Ohm meter. 5. Application examples 5. Standard Single Tank System P: Solar circuit pump P: Heating circuit pump P3: Tank charging pump Vr: Switch-over valve for return temperature increase Collector field T: Collector sensor T: Tank sensor, bottom T3: Tank sensor, middle T4: Sensor heating return-flow T3 T A T4 A T T Version TEMO Combi Cylinder Hot water Cold water Heating circuit TEMO Ttw T3 P3 P P T A Vr B AB Oil or gas boiler CICO T4 Measuring the yield Collector field T T5 D Solar return-flow Figure 4 Standard single tank system controlled by SUNGO SL. EN-SUNGO-SL-BA-0804-P300

12 5. Standard Dual Tank System P: Solar circuit pump P: Heating circuit pump P3: Tank charging pump Vu: Switch-over valve, tank charging Collector field T: Collector sensor T: Tank sensor, bottom T3: Tank sensor, top T4: Tank sensor, bottom T3 T T4 A A T Heating circuit P P ECOplus CICO Oil or gas boiler P3 A AB Measuring the yield M B V Collector field T D T5 Solar return-flow Hot water Cold water Figure 5 Standard dual tank system controlled by SUNGO SL. 5.3 SECUSOL System T: Collector sensor T: Tank sensor, bottom T3: Tank sensor, top (optional) Collector field (EUO C) P: Solar circuit pump P: Heating circuit pump P3: Tank charging pump Ttw: Hot water sensor (heating control) BWM: Thermostatic mixing valve T3 T A T T Heating circuit Ta Ttw P T3 SECUSOL T Oil or gas boiler P3 P Measuring the yield Collector field T T5 Hot water BWM D Solar return-flow Cold water Figure 6 SECUSOL system controlled by SUNGO SL. Subject to modifications, errors excepted. Wagner & Co, WAGNE & CO Zimmermannstraße D-3509 Cölbe/Marburg Fax

CIRCO 6 Solar Circulation Unit

CIRCO 6 Solar Circulation Unit TECHNICAL INFORMATION / INSTALLATION INSTRUCTIONS CIRCO Solar Circulation Unit CIRCO Solar Circulation Unit in combination with the intelligent SUNGO controllers, it is the safe and reliable heart of a

More information

Installation and Operating Manual

Installation and Operating Manual Installation and Operating Manual SR868C6 System Regulator for Solar Thermal Systems Display Panel Illustration Pos. Button on display panel Button description 1 Green lamp Power indication lamp 2 On/Off

More information

SR-5/2D Solar-Power-Regulator

SR-5/2D Solar-Power-Regulator T self-optimising controller for solar hot water plants SR-5/2D Solar-Power-Regulator European Patent No. 0 880 659 U.S. Patent No. 6.047.696 Canadian Patent 2,249,018 Subject to technical alterations

More information

SD2. Differential Controller. Operating and Installation Instructions F2 72.3

SD2. Differential Controller. Operating and Installation Instructions F2 72.3 SD2 Differential Controller Operating and Installation Instructions F2 72.3 i Please follow the safety information and read these Instructions carefully before putting the system into operation. Safety

More information

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION Environment IMPORTANT INFORMATION It is not anticipated that this equipment will be exposed to adverse environmental conditions without additional protection. Site the equipment in a frost free area. Ensure

More information

Operating instructions

Operating instructions SOLARTHERMIE - SOLAR THERMAL - SOLAR TÉRMICO - SOLAIRE THERMIQUE Operating instructions Temperature Differential Controller inputs, 1 output These operating instructions are part of the product. US Read

More information

EN Z Subject to change due to technical improvements! Operating instructions

EN Z Subject to change due to technical improvements! Operating instructions SOLARTHERMIE - SOLAR THERMAL - SOLAR TÉRMICO - SOLAIRE THERMIQUE Operating instructions Temperature differential controller 3 inputs, 1 output These operating instructions are part of the product. Read

More information

Lago SD3. Differential Controller with Speed Control. Operating and Installation Instructions

Lago SD3. Differential Controller with Speed Control. Operating and Installation Instructions Lago SD3 Differential Controller with Speed Control Operating and Installation Instructions Please observe the safety instructions and read through this manual carefully before commissioning the equipment.

More information

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

1 DOCUMENT REVISION CONTROL ELEMENTS... 9 CONTENTS Contents 1 DOCUMENT REVISION... 8 2 SOFTWARE VERSION... 8 3 BASIC DESCRIPTION... 8 4 CONTROL ELEMENTS... 9 4.1 BASIC DISPLAYS...10 4.2 CONTROL KEYS...11 4.2.1 Rotary button (Press / Turn)...11

More information

Operation Manual of Solar controller SR1568 for split solar system

Operation Manual of Solar controller SR1568 for split solar system Operation Manual of Solar controller SR1568 for split solar system Read the instruction carefully please before operation! Contents 1. Safety information... 4 1.1 Installation and commissioning... 4 1.2

More information

MIX Boiler & Font Range Service Manual

MIX Boiler & Font Range Service Manual MIX Boiler & Font Range Service Manual 1000870# 1000871# 1000875# 1000880# 1000887# 1000878 1000879 2300268 www.marcobeveragesystems.com Ireland Tel: +353 (1) 295 2674 UK Tel: +44 (0207) 2744577 Service

More information

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card SOLARTHERMIE - SOLAR THERMAL - SOLAR TÉRMICO - SOLAIRE THERMIQUE - SOLARE TERMICO Installation and operating instructions Temperature difference controller 6 inputs, 3 outputs, integrated data logger for

More information

Instructions for Use. To b e l e f t w i t h t h e u s e r. Clearly Solar System. including. Fluropro. Solar Differential Controller

Instructions for Use. To b e l e f t w i t h t h e u s e r. Clearly Solar System. including. Fluropro. Solar Differential Controller Instructions for Use To b e l e f t w i t h t h e u s e r Clearly Solar System including Fluropro Solar Differential Controller 1 www.glow-worm.co.uk WARNINGS SAFETY The fluropro must be installed by a

More information

* * EC1. Variable controller for circulation systems Mounting and operation manual

* * EC1. Variable controller for circulation systems Mounting and operation manual variable controller for circulation systems adaptive pump control easy-to-install housing user-friendly operation by simple handling intuitive menu operation via push button Technical data RESOL EC1 Housing:

More information

User Manual. Electric Heating Element MEG DRY MOA REG 2 REG 3

User Manual. Electric Heating Element MEG DRY MOA REG 2 REG 3 User Manual Electric Heating Element MEG DRY MOA REG 2 REG 3 User Manual Our products have been designed and manufactured in such a way to ensure that all quality, functionality and aesthetic requirements

More information

Digital Electronic Thermostat With RF

Digital Electronic Thermostat With RF RT300RF Manual:89 6/7/10 12:52 Page 1 Digital Electronic Thermostat With RF Instruction Manual Model No RT300RF 2 RT300RF Manual:89 6/7/10 12:52 Page 2 2 RT300RF INSTRUCTION MANUAL RT300RF Manual:89 6/7/10

More information

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1 HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1 INSTALLATION, COMMISSIONING AND OPERATING INSTRUCTIONS Contents Unit as delivered

More information

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63 Fire Extinguishing Control Panel FS5200Е INSTRUCTION MANUAL Revision 8/01.17 Instruction Manual Page 1 1. 2. 3. 4. 4.1. 4.2. 4.2.1. 4.2.2. 4.2.3. 4.2.4. 4.2.5. 4.2.6. 4.2.7. 4.2.8. 4.2.9. 4.2.10. 4.2.11.

More information

LC2200 Level Controller Installation and Maintenance Instructions

LC2200 Level Controller Installation and Maintenance Instructions 4025250/9 IM-P402-77 AB Issue 9 LC2200 Level Controller Installation and Maintenance Instructions LC2200 ALARM TEST >50% >100%

More information

Q - Series Boiler. Troubleshooting Manual

Q - Series Boiler. Troubleshooting Manual Q - Series Boiler Troubleshooting Manual WARNING There are a number of live tests that are required when fault finding this product. Extreme care should be used at all times to avoid contact with energized

More information

- Data Brochure Steam Control 279

- Data Brochure Steam Control 279 - Data Brochure Steam Control 279 D 279 12/07 The tekmar Steam Control 279 can operate a single on-off steam boiler or an on-off steam valve using outdoor reset. The control determines the on time of the

More information

RE-PR3-E-27 3-Phase Panel Mount 27kW

RE-PR3-E-27 3-Phase Panel Mount 27kW Page 1 of 6 RE-PR3-E-27 3-Phase Panel Mount 27kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting

More information

Electronic Pellet Burner Controller NPBC-V3-1

Electronic Pellet Burner Controller NPBC-V3-1 Electronic Pellet Burner Controller NPBC-V3- SOFTWARE VERSION 3.2/3. page of 3 CHANGES IN THE TECHNICAL AND USER GUIDE OR IN THE SOFTWARE VERSION Technical and User Guide's version Changes Page 2.8. The

More information

User Manual for model

User Manual for model User Manual for model RKA 24 /20 Wall mounted storage combi boiler premix condensing boiler CE 0694 Technical specification RADIANT BRUCIATORI S.p.A. Montelabbate RKA 24.20 - RAD - ING - MAN.UT - 1309.1

More information

Digital Electronic Thermostat With RF

Digital Electronic Thermostat With RF Digital Electronic Thermostat With RF Instruction Manual Model No RT300RF PRODUCT COMPLIANCE This product complies with the essential requirements of the following EC Directives: Electro-Magnetic Compatibility

More information

Room panel. for ecomax800 R or T regulators. OPERATION AND MAINTENANCE MANUAL ISSUE: 1.3 APPLICABLE TO SOFTWARE: v , v , v08.21.

Room panel. for ecomax800 R or T regulators. OPERATION AND MAINTENANCE MANUAL ISSUE: 1.3 APPLICABLE TO SOFTWARE: v , v , v08.21. Room panel ecoster 200 for ecomax800 R or T regulators OPERATION AND MAINTENANCE MANUAL ISSUE: 1.3 APPLICABLE TO SOFTWARE: v08.21.014, v08.21.015, v08.21.016 2010-08-31 TABLE OF CONTENTS 1. SAFETY...

More information

Electronic Pellet Burner Controller NPBC-V3M

Electronic Pellet Burner Controller NPBC-V3M Electronic Pellet Burner Controller NPBC-V3M SOFTWARE VERSION 3.3a/3.2 page of 27 CHANGES IN THE USER MANUAL OR IN THE CONTROLLER'S SOFTWARE Version of the user manual Changes Page 2.2. The software version

More information

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440) Safety Temperature Limiter STL 50 Certified to DIN EN 14597 (replaces DIN 3440) Features M For use as: STB Protection - temperature limiter ASTB Exhaust gas - protection - temperature limiter STW Protection

More information

EBC20. Instructions for fitting, installation and operation. Read and save these instructions!

EBC20. Instructions for fitting, installation and operation. Read and save these instructions! EBC20 UK Instructions for fitting, installation and operation Read and save these instructions! 2 3002878 EBC20 UK 290415 1. Product information............................................... 4 1.1 Delivery.............................................................

More information

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502*

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502* User's Guide VI.7B.D5.02 2005.10 P20 *VI7BD502* *087R8014* www.danfoss.com ECL Comfort User's Guide ECL Comfort Installer's Guide www.danfoss.com *087R8014* *VI7BD502* Boiler controller P20 VI.7B.D5.02

More information

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen

Product Instructions. Hydronic Mixing Block Version Wiring Terminal Block Pressure/Temperature Sensor Delivery Fitting (3) Display Screen Hydronic Mixing Block Version 1.104 The Hydronic Mixing Block is a mixing device and boiler control, with a built in circulator and system controller. The block can provide either a fixed or reset water

More information

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS... User Manual Contents 1 DOCUMENT REVISION... 4 2 SOFTWARE VERSION... 4 3 BASIC DESCRIPTION... 4 4 BASIC OVERVIEW OF HYDRAULIC DIAGRAMS... 5 4.1 BOILER NOT CONTROLLED BY THE CONTROLLER:... 5 4.2 BOILER CONTROLLED

More information

OPERATING MANUAL Enertronic Control System 2

OPERATING MANUAL Enertronic Control System 2 OPERATING MANUAL Enertronic Control System 2 The integrated control system for Lennox chillers in the Ecologic range Manufacturer: Lennox Benelux B.V. Postbus 1028, 3860 BA NIJKERK Watergoorweg 87, 3861

More information

MANUAL INTELLIVENT CELSIUS

MANUAL INTELLIVENT CELSIUS MANUAL INTELLIVENT CELSIUS EN Thank you for choosing this product from Simx. Before installing and using the fan, read through these instructions. Keep them safe for reference in future. SPECIFICATIONS

More information

KTX 1, KTX 2, KTX 3, KTX 4. User Manual Electric Heating KTX 1, KTX 2, KTX 3, KTX 4.

KTX 1, KTX 2, KTX 3, KTX 4. User Manual Electric Heating KTX 1, KTX 2, KTX 3, KTX 4. KTX 1, KTX 2, KTX 3, KTX 4. User Manual Electric Heating KTX 1, KTX 2, KTX 3, KTX 4. en Our products have been designed and manufactured in such a way to ensure that all the quality, functionality and

More information

Focus 4010\ Focus 4010 HT porcelain firing furnace

Focus 4010\ Focus 4010 HT porcelain firing furnace INSTRUCTION MANUAL Focus 4010\ Focus 4010 HT porcelain firing furnace Warning You have available one of the most precise dental furnaces equipped with a heating muffle made by the original manufacturer

More information

RT021 User and Installation Instructions

RT021 User and Installation Instructions RT021 User and Installation Instructions Battery Operated Electronic Room Thermostat with TPI Temperature Control Software 1 2 The RT021 is a battery powered electronic room thermostat designed to provide

More information

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd. F-2000 PC and AO OUTPUT BOARDS INSTRUCTION MANUAL Blue-White R Industries, Ltd. 500 Business Drive Huntington Beach, CA 92649 USA Phone: 714-89-8529 FAX: 714-894-9492 E mail: sales@blue-white.com or techsupport@blue-white.com

More information

GEM-C Wireless User & Installation Manual. Revision October Apollo Solar Electric Limited. Documentation

GEM-C Wireless User & Installation Manual. Revision October Apollo Solar Electric Limited. Documentation Documentation GEM-C Wireless User & Installation Manual Revision October 2014 Apollo Solar Electric Limited Contents GEM-C Wireless User Manual 3 Important Safety Information 3 Introduction 4 The GEM-C

More information

Rules for Intruder Alarm Systems

Rules for Intruder Alarm Systems Rules for Intruder Alarm Systems Opening detectors (Magnetic contacts) Part 1: Requirements VdS 2120en 03/96 (03) Subject 44 1 General; 2 Terms and definitions; 3 Classification 1 General 1.1 Scope These

More information

PRELIMINARY EDITION

PRELIMINARY EDITION 3 131 PRELIMINARY EDITION 14.01.2003 Synco 700 Heating Controllers Heating controller for medium-size and large buildings. The is used as a heating circuit or primary controller. The controller is supplied

More information

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems) ISOMETER IR425 Insulation monitoring device for unearthed AC/DC control circuits (IT systems) IR425-D4_D00039_04_D_XXEN/05.2017 ISOMETER IR425 Insulation monitoring device for unearthed AC/DC control circuits

More information

Installation and user manual

Installation and user manual Installation and user manual Please read carefully and retain for future reference Models EcoHeat: C3, C5, C6, C8, C9, C11, C12 Rev.1_09-07-15 Page 1 Table of Contents 1 IMPORTANT: WARNINGS 1.1 GENERAL

More information

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb. Edition 06.14 GB Operating and installation instructions Lago FB digital remote control Translation from the German 2014 Elster GmbH Safety Please read and keep in a safe place Please read through these

More information

Type ETO2. Controller for ice and snow melting 67222A 04/14 (JRK) GREEN COMFORT Maximum comfort with low energy consumption OJ Electronics A/S

Type ETO2. Controller for ice and snow melting 67222A 04/14 (JRK) GREEN COMFORT Maximum comfort with low energy consumption OJ Electronics A/S Controller for ice and snow melting 67222A 04/14 (JRK) GREEN COMFORT Maximum comfort with low energy consumption English Instruction ETO2 is an electronic controller for fully automatic, economical ice

More information

1.1 Controller General Information

1.1 Controller General Information 1.1 Controller General Information The Aestiva S1000 controller is differential controller specifically designed for forced circulation solar system. It incorporates a microprocessor driven PCB board and

More information

IFP-2.32 Manual 1) DESCRIPTION ICAS FIRE PANEL IFP 2.32

IFP-2.32 Manual 1) DESCRIPTION ICAS FIRE PANEL IFP 2.32 1) DESCRIPTION IFP-2.2 Manual IFP-2.8 and IFP-2.2 is a microprocessor controlled Fire Panel with 2 loops intended either for privat Homes & Apartments or larger installations. The two loops are balanced

More information

C37. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C37. User's Guide. Installer's Guide *VI7CE602* *087R8070* *087R8070* *VI7CE602*

C37. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C37. User's Guide. Installer's Guide *VI7CE602* *087R8070* *087R8070* *VI7CE602* User's Guide VI.7C.E6.02 2005.09 C37 *VI7CE602* *087R8070* www.danfoss.com ECL Comfort User's Guide ECL Comfort Installer's Guide www.danfoss.com *087R8070* *VI7CE602* Mixing controller with ON / OFF controlled

More information

Operating instruction. Remote control station WCM-FS /

Operating instruction. Remote control station WCM-FS / 83277702 1/22-04 1 User instructions... 4 1.1 User instructions... 4 1.2 User guide... 4 1.2.1 Symbols... 4 1.2.2 Target group... 4 1.3 Guarantee and Liability... 4 2 Safety... 5 2.1 Permissible application...

More information

ivector HEATER/COOLER 2 AND 4-PIPE MODELS.

ivector HEATER/COOLER 2 AND 4-PIPE MODELS. 25278 ivector Installation Guide US 02/01/2013 09:24 Page 2 ivector HEATER/COOLER 2 AND 4-PIPE MODELS. INSTALLATION, OPERATING, MAINTENANCE & AFTER SALES MANUAL JANUARY 2013, ISSUE 1 Product Serial Number:

More information

Supplement to operating and installation manual no for the VR 81 remote control unit

Supplement to operating and installation manual no for the VR 81 remote control unit Supplement to operating and installation manual no. 0020044392 for the VR 81 remote control unit The VR 81/2 remote control unit can be used together with the VRC 430/VRC 430f and VRC 470 compensator types.

More information

Commissioning a Solar Thermal Installation

Commissioning a Solar Thermal Installation OPERATING INSTRUCTIONS Wagner& Co Commissioning a Solar Thermal Installation Contents. Solar Circuit... 2. Commissioning... 3 3. Service Information... 4. Maintenance.... Solar Circuit Components Pipework

More information

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S EN OPERATING MANUAL INFRARED HEATING PANEL TRT-BA-TIH300S-TIH400S-TIH500S-TIH700S-TIH900S-TIH1100S-TC-002-EN Table of contents Notes

More information

Refrigerator KE T

Refrigerator KE T Refrigerator KE 680-1-3T Service Manual: H8-74-07 Responsible: U. Laarmann KÜPPERSBUSCH HAUSGERÄTE AG E-mail: uwe.laarmann@kueppersbusch.de Tel.: (0209) 401-732 Customer Service Fax: (0209) 401-743 Postfach

More information

Service instructions. FM443 solar module. Function module. For contractors. Read carefully prior to commissioning or service

Service instructions. FM443 solar module. Function module. For contractors. Read carefully prior to commissioning or service Service instructions Function module FM443 solar module For contractors Read carefully prior to commissioning or service 6 720 615 516-03/2008 GB/IE Contents 1 Safety........................................

More information

System Installation. multi-zone heating

System Installation. multi-zone heating System Installation multi-zone heating Table of contents INTRODUCTION 1 Instructions guidance... 2 1.1 Product documentation...2 1.2 Associated documents...2 1.3 Explanation of symbols...2 1.4 Guarantee

More information

Isolation Relay: If Needed. # 9. NO relay for TT To Thermostat NO relay. MZ308 Exquisite Heat Controller

Isolation Relay: If Needed. # 9. NO relay for TT To Thermostat NO relay. MZ308 Exquisite Heat Controller #4. 24 Volt AC & for 24 AC supply to thermostat if needed Isolation Relay: If Needed. # 9. NO relay for TT To Thermostat NO relay #12. To Thermistor for Domestic hot water Supply from boiler Orange & Brown

More information

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions Autofill wall mounted water boiler Please read and keep these instructions For Burco wall mounted boilers 76700 (SKU 444448534), 76702 (SKU 444448546), & 76704 (SKU444448548) Getting the best from your

More information

Operating Instructions Model: PRT-RP Version 3. 05/11 Revision 2 Ref: PRTRP

Operating Instructions Model: PRT-RP Version 3. 05/11 Revision 2 Ref: PRTRP Operating Instructions Model: PRT-RP Version 3 05/11 Revision 2 Ref: PRTRP Contents Page What is a programmable thermostat? 2-4 Installation 5-6 Icons explained 6 Temperature Display 7 Setting the Clock

More information

G2484. Installation. - Control panel (in the panel front, on the inner wall, or on a DIN rail)

G2484. Installation. - Control panel (in the panel front, on the inner wall, or on a DIN rail) 74 319 0400 0 G2484 en Installation Instructions Solar Energy Manager RVP502 Installation Place of installation In a dry room, e.g. in the boiler room Installation choices: - Control panel (in the panel

More information

Generated Energy Management System. User Manual and Installation Manual. Documentation. Revision 8, November Apollo Solar Electric Ltd

Generated Energy Management System. User Manual and Installation Manual. Documentation. Revision 8, November Apollo Solar Electric Ltd Documentation Generated Energy Management System User Manual and Installation Manual Revision 8, November 2017 Apollo Solar Electric Ltd Contents Important Safety Information 4 Introduction 5 The Apollo

More information

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE Technical features Guide to LCD symbols Guide to keys Technical features Supply by communication bus Number of temperature levels 2 (DAY / NIGHT) Temperature

More information

TERMO Combi Cylinder TECHNICAL INFORMATION

TERMO Combi Cylinder TECHNICAL INFORMATION TECHNICAL INFORMATION TERMO Combi Cylinder Tank-In-Tank System using solar energy for hot water and heating support. For integration into the heating circuit as return flow booster or hydraulic compensator.

More information

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE

Installation instructions. For the competent person. Installation instructions VRT 350 VRT 350 GB, IE Installation instructions For the competent person Installation instructions VRT 350 VRT 350 GB, IE Legal information Document type: Product: VRT 350 Target group: Language: Installation instructions Authorised

More information

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English Rectifier RC-series Manual RC-series English Manual Wall and 19 English Presentation The RC-series is a rectifier for either directly powering the load or for use together with batteries. It is designed

More information

Chlorine gas leak detector

Chlorine gas leak detector INSTRUCTION MANUAL FOR Chlorine gas leak detector with battery back up series M 4510 C 2007 Controlmatik ABW d.o.o. 1 CONTENT 1.0 General description:... 3 2.0 The Unit... 4 3.0 Controls and Displays...

More information

FirePro control MANUAL

FirePro control MANUAL control MANUAL Door control for FailSafe (FS) motors HW version 1.3 SW version 1.4 English Table of Contents 1 Description of the Control...2 2 Safety Instructions...3 3 Mounting...4 4 Connecting...5 5

More information

ST 53.1 User s manual

ST 53.1 User s manual Tech - 1 - ST 53.1 User s manual Table of contents I. Safety... 3 II. Description... 4 III. Installation... 4 IV. Operating the Controller... 6 IV.a) Principle of Operation... 6 IV.b) Control... 6 V. Controller

More information

Installation and Operating Manual. System Regulator for Solar Thermal Systems 7 inputs, 4 outputs

Installation and Operating Manual. System Regulator for Solar Thermal Systems 7 inputs, 4 outputs SOLARTHERMIE - SOLAR THERMAL - SOLAR TÉRMICO- SOLAIRE THERMIQUE - SOLARE TERMICO Installation and Operating Manual System Regulator for Solar Thermal Systems 7 inputs, 4 outputs These operating instructions

More information

Curv-infrared.com. The Smarter Way. To Heat Your Home. Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters

Curv-infrared.com. The Smarter Way. To Heat Your Home. Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters Curv-infrared.com The Smarter Way To Heat Your Home Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters Safety Precautions Important Notice To Purchaser Before

More information

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET DT90 DIGITAL ROOM THERMOSTAT PRODUCT SPECIFICATION SHEET The new DT90 family of digital room thermostats is a range of market leading products designed to provide comfort with economy in modern heating

More information

ETO 2 - Controller for ice and snow melting

ETO 2 - Controller for ice and snow melting ETO 2 - Controller for ice and snow melting Advantages Simple adjustment knob with two functions Illuminated display where you can easily see the temperature status and other values Controls both pumps

More information

ST Wiring diagram. Product description. Four-stage controller. Order number

ST Wiring diagram. Product description. Four-stage controller. Order number ST96-35.16 Four-stage controller Order number 99.2 Wiring diagram Product description The four-stage controller with 4-digit setpoint and actual value display, 3 keys and 4 relays was developed for the

More information

ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data.

ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data. ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data. The RVA 46 Zone Controller can only be used in conjunction with a RVA47 controlled boiler installation. The RVA46 controller

More information

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28 The competent brand for energy saving systems NEW Gas-combi boiler CGG-1K-24/28 Gas-combi boiler CGG-1K Technical data room sealed fannned flue model gas combi boiler for low temperature heating and d.h.w.

More information

ECOplus Solar Cylinder

ECOplus Solar Cylinder TECHNICAL INFORMATION ECOplus Solar Cylinder Minimized Heat Loss due to convection brakes in the pipe connections, the new close-fitting, 00-mm thick PU soft foam jacket insulation, 0-mm thick and close

More information

Electronic Dual Cylinder Thermostat Installation Instructions

Electronic Dual Cylinder Thermostat Installation Instructions ESCTDEB Electronic Dual Cylinder Thermostat Installation Instructions Thank you for choosing ESi Controls. All our products are tested in the UK so we are confident this product will reach you in perfect

More information

EUROSTER 11Z CENTRAL HEATING / UTILITY HOT WATER PUMP CONTROLLER

EUROSTER 11Z CENTRAL HEATING / UTILITY HOT WATER PUMP CONTROLLER EUROSTER 11Z USER MANUAL 1 EUROSTER 11Z CENTRAL HEATING / UTILITY HOT WATER PUMP CONTROLLER MANUFACTURER: P.H.P.U. AS, Polanka 8a/3, 61-131 Poznań, POLAND 1 INTRODUCTION Carefully study this user manual

More information

- Data Brochure D 260. Boiler Control /09

- Data Brochure D 260. Boiler Control /09 - Data Brochure Boiler Control 260 D 260 03/09 The Boiler Control 260 is designed to control a single stage heat source in order to provide outdoor reset or Domestic Hot Water () operation. The control

More information

DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS

DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS DOMESTIC HEATING CONTROLS ARE EASY PART 1 - THE BASICS Today s inescapable need to improve energy efficiency in UK homes has brought installers many opportunities to make extra earnings through the upgrading

More information

- Data Brochure Mixing Control 361

- Data Brochure Mixing Control 361 TIME PRGM 1 2 AMPM UN OVR S M T W T F S - Data Brochure Mixing Control 361 D 361 05/00 The Mixing Control 361 is designed to control the supply water temperature to a hydronic system in order to provide

More information

Archive. LC2200 Level Controller. 1. Safety information. 2. General product information. 3. Installation. 4. Setting up the controller

Archive. LC2200 Level Controller. 1. Safety information. 2. General product information. 3. Installation. 4. Setting up the controller 4025250/10 IM-P402-77 AB Issue 10 LC2200 Level Controller Installation and Maintenance Instructions 1. Safety information 2. General product information 3. Installation 4. Setting up the controller 5.

More information

APC BC300 Series 40kW 208/450/480V User Guide

APC BC300 Series 40kW 208/450/480V User Guide APC BC300 Series 40kW 208/450/480V User Guide Copyright 2002 APC Denmark ApS This manual is subject to change without notice and does not represent a commitment on the part of the vendor Thank You Thank

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL CONTROL PANEL RIELLOtech PRIME INSTALLATION, OPERATION AND MAINTENANCE MANUAL CONFORMITY RIELLOtech control panels conform to: Low Voltage Directive 06/95/EC (ex-directive 73/23/EEC) Electromagnetic Compatibility

More information

RF Programmable Room Thermostat Installation Instructions

RF Programmable Room Thermostat Installation Instructions ESRTP4RF RF Programmable Room Thermostat Installation Instructions Thank you for choosing ESi Controls. All our products are tested in the UK so we are confident this product will reach you in perfect

More information

EUROBOX SERIES TYPES CM... SM... MM...

EUROBOX SERIES TYPES CM... SM... MM... EUROBOX SERIES TYPES CM... SM... MM... AUTOMATIC GAS BURNER CONTROL SYSTEMS FOR GAS BURNERS AND GAS BURNING APPLIANCES WITH OR WITHOUT FAN Application This range of electronic gas burner control systems

More information

Module Features are-configurable, no module jumpers to set

Module Features are-configurable, no module jumpers to set December 2011 PACSystems* RX3i Isolated Thermocouple Input Module, 6 Channels, IC695ALG306 Isolated Thermocouple Input Module, 12 Channels, IC695ALG312 Isolated Thermocouple Input module IC695ALG306 provides

More information

LC3000 Level Controller Installation and Maintenance Instructions

LC3000 Level Controller Installation and Maintenance Instructions 4025550/12 IM-P402-36 AB Issue 12 LC3000 Level Controller Installation and Maintenance Instructions 1. General safety information LC3000 NORM ALARM TEST 2. General product information 3. Installation 4.

More information

Operating instructions

Operating instructions Operating instructions For the operator Operating instructions ecotec plus Gas-fired wall-hung high-efficiency boiler GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Telefon

More information

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL USER'S INFORMATION MANUAL WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use

More information

SERVICE MANUAL REFRIGERATION

SERVICE MANUAL REFRIGERATION SERVICE MANUAL REFRIGERATION ELECTROLUX HOME PRODUCTS S.p.A. Publication no. Spares Operations Italy 599 37 75-07 Corso Lino Zanussi, 30 060824 I - 33080 PORCIA / PN (ITALY) ITZ/SERVICE/AA Fax +39 0434

More information

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2 UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2 Version: 2018_07_19_v2.2 Abstract This is a quick reference guide for selecting the UniQ range of heat batteries for the required application. For designing a

More information

Farm Hand CCU 111 / CCU 10R. Manual for use and maintenance. Farm Hand. Climate Controller. HC/MMA/UmGB /13 rev 1.

Farm Hand CCU 111 / CCU 10R. Manual for use and maintenance. Farm Hand. Climate Controller. HC/MMA/UmGB /13 rev 1. Manual for use and maintenance Farm Hand CCU 111 / CCU 10R Farm Hand Climate Controller HC/MMA/UmGB-2043-01/13 rev 1.8 P/N: 110131 Farm Hand CCU 111, Farm Hand CCU 10R Manual for use and maintenance Revision:

More information

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App Heating is great when you control it. USER MANUAL Wireless Programmable Room Thermostat Model No.: LS99111010 Scan for App Contents 1. Overview... 01 2. System Installation... 02 2.1 Install and Wiring

More information

1 Dimensions Installation Mains/boosted cold water inlet Connection to the system Drain Dimension for fixing 6

1 Dimensions Installation Mains/boosted cold water inlet Connection to the system Drain Dimension for fixing 6 Electronic Filling Device (EFD) Installation and Maintenance Instructions Contents 1 Dimensions 3 1.1 Installation 4 1.1 Mains/boosted cold water inlet 4 1.2 Connection to the system 5 1.3 Drain 5 1.4

More information

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas User s Manual TIGER S EYE E-Series Mark V Jockey TIGERFLOW Systems, Inc. 4034 Mint Way Dallas, Texas 75237 214-337-8780 www.tigerflow.com TABLE OF CONTENTS Introduction... 4 Sequence of Operation... 5

More information

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep. Power Supply/Chargers Installation Guide Models Include: eflow4na8d - 4A @ 12VDC or 24VDC - Eight (8) PTC Outputs eflow6na8d - 4A @ 12VDC or 24VDC - Eight (8) PTC Outputs eflow102na8d - 10A @ 12VDC - Eight

More information

Operating Guide. ECL Comfort 210 / 296 / 310, application A247 / A Table of Contents

Operating Guide. ECL Comfort 210 / 296 / 310, application A247 / A Table of Contents 1.0 Table of Contents 1.0 Table of Contents... 1 1.1 Important safety and product information..................... 2 2.0 Installation... 6 2.1 Before you start.....................................................

More information

AURATON 2005 / 2005 TX

AURATON 2005 / 2005 TX AURATON 2005 / 2005 TX USER MANUAL PP LARS 2003 Thank you for purchasing the AURATON 2005. Your new programable thermostat will serve your family for years and significantly save the energy cost. The large

More information

User Manual 120/240/300 Outdoor Motion Detector

User Manual 120/240/300 Outdoor Motion Detector User Manual 120/240/300 Outdoor Motion Detector Swiss Garde 4000 Warning! - Any work on the main power supply must only be completed by trained specialists. - The product must be installed in accordance

More information