1 COTES CROUK DEHUMIDIFIER. PRODUCTION NO. : STOCK NO. : DOCUMENT NO. 01LK-01E INSTALLATION AND INSTRUCTION MANUAL PAGE CONTENT 1 1. Principle of operation, capacity 3 2. Applications 4 3. Dimensions 5 4. Components diagram 7 5. Technical data, CR range 6. Electric features : Electrical diagram Wiring in cabinet Electric components Connection of hygrostat Electric connection, energy consumption & airflows Installation Commissioning Maintenance Trouble shooting Service/repair 13.1 Safety instructions Taking the unit apart Sound level Cotes A/S Industrivej 31A. DK 4230 Skaelskoer. CVR/VAT: DK T: F: info@cotes.dk.

2 EU declaration of conformity Cotes A/S Industrivej 31A DK-4230 Skaelskoer VAT no. DK CE Declares at its own liability that the following models of Cotes adsorption dehumidifiers: CR100, CR150, CR200, CR300, CR450, CR600, CR750, CR800T, CR900, CR1200, CR12005, CR1400T, CR1500, CR2000, CR2500, CR2400T, CR3200T, CR3800T, CR5000T, CR7000TE, CR80B, CR80B-FC, CR110B, CR11OBT, CR240B, CR24OBT, CR24085, CR150B, CR15OBT, CR300B, CR300BT, CR180B, CR200B, CR200BT, CR400B, CR400BT, CR400BS, CRO1LK, CR110LK, CR160LK, CR300LK, CR600LK, CR750LK, CR900LK, CR1200LK, CRP2000E/D/G, CRP4000E/D/G/V, CRP6000E7D/G, CRP8000E/D/G, CRP12000E/D/G, CRP18000E/D/G, CRP25000E/D/G, CRP30000E/D/C, CRP40000E/D/G, CRT3000E/D/G, CRT6000E/D/G/V, CRT9000E/D/G, CRT12000E/D/G, CRT18000E/D/G are covered by this declaration complying with the following directives: Machinery Directive 2006/42/EC Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC and are manufactured in compliance with the following harmonised standards: EN :2003 Safety of machinery - basic concepts, general principles for design Part 1: Basic terminology, methodology EN :2003 Safety of machinery - basic concepts, general principles for design Part 2: Technical principles and specifications EN :2006 Safety of machinery electrical equipment Part 1: General requirements EN :2001 Electromagnetic compatibility (EMC) Part 6-4: Generic standards - Emission standard for industrial environments EN :2005 Electromagnetic compatibility (EMC) -- Part 6-2: Generic standards - Immunity for industrial environments DK-S eiskoer SOren Olesen Cotes A/S industrivej 31A. DK 4230 Skaelskoer CVR, VAT: DK T: F: infoe'cotes.dk.v.cotes.dk

3 Page 1 1. PRINCIPLE OF OPERATION. The dehumidifier removes water from an airflow through, and the removed water is carried away from the dehumidifier with the regeneration air (henceforward called reg.-air). Water adsorption and -extraction takes place in a rotor made of water resistant silica gel. The air flows in the dehumidifier divides the rotor in two parts : drying part and reg.-part. Two separate air flows passes through the rotor: - the process air passes the drying part, which is 75% of the rotor material. In the rotor, part of the water content is adsorped and the air leaves the rotor as dry air - the reg.-air is a closed circuit: - in the electric heater it is heated to app. 100C - passing the reg.section of the rotor (25% of the rotormaterial) the energy is used for evaporating the adsorped water, which is then carried out of the rotor - the air is then cooled in the heat exchanger and the water will condensate and leave the dehumidifier as free water. The two air flows are fixed and the rotor turns - this gives an automatic process of simultaneous water adsorption and water extraction (see principle of operation, drawing R1213 page 2). The heat exchanger is cooled by the cooling air, which has common inlet with the process air (see principle, fig. 1, page 2). CAPACITY. Process air inlet C / %rf / g/kg Capacity Kg/h 15 / 60 / 6,3 0,38 15 / 40 / 4,2 0,28 10 / 60 / 4,6 0,32 10 / 40 / 3,0 0,23 5 / 60 / 3,2 0,28 5 / 40 / 2,1 0,20 The temperature of the dry air is higher than for the inlet air. This is caused by the evaporation heat release and heat gain from the rotor. The temperature is shown to be 35C.

4 c J Drying section 0 a B 4-) 4.) > 0.) GA C dl -P C 1 (1..1 (1.1 o IY -14 d R C CO Oa Q1 Process air fan Process- and cooling air REG.-LUFT audiment technology Heat exchanger -II 0 0 Cooling air outlet d r=i X Industrivej 31A DK-4230 Skaz Iskor Dry air outlet

5 Page 3 2. APPLICATIONS. Dehumidifiers in the CR-LK range is used for dehumidification of ambient air at normal atmospheric pressure. This can be an installation for moisture control in an unheated store room, in a water work building, production room for hygroscopic materials... - with the dehumidifier in a separate installation. Normally the dehumidifier will be placed on the floor, on a table or in a wall bracket (option). It should always be placed horizontal, resting on the four pcs. rubber supports. The air to the dehumidifier should be free from solvents or other explosive components, exhaust gases from Diesel engines and should be free from pollution from solid particles. For air to the dehumidifier the following limit values must be respected : - max. humidity 100 %RH - max. temperature 35C *) - max./min. pressure ambient +/- 300Pa The CR-LK range is for indoor, stationary installations. Should not be placed in rooms with possibility for free water on the cabinet. *) at inlet air temperatures higher than 20C or at %rh lower than 30%, a reduction of the capacity must be considered.

6 t 1- N DO N N Z 9a COTES audiment technology 7 Drawn I COTES A/S 0 CO CD V CO

7 I co co E z o - (.9 a iv COTES audiment technology 0 z 0 2 LI) L) CO

8 Page 6 4. COMPONENTS DIAGRAM CRO1LK. (ref. to drawing R123550) 1 1 Filter cassette 165x210x48 mm, G4 2 1 Connector, Hygrostat connection 3 1 Fan, for process - and cooling air 4 Electric terminals 5 2 Toggle switch Left: Red, dehumidifier on/off Right: Black, dehumidifier man/auto 6 1 Hour counter 7 1 Fan, reg.air 8 1 DN 80 mm, dry air outlet 9 1 Wall bracket 10 1 Condensate pipe (drain) 11 1 PTC heatere for reg.air 12 1 Heat exchanger 13 1 PPS Rotor, 220/ Sala Motor and gearbox for rotor

9 Page 7 5. TECHNICAL DATA, SPECIFICATIONS CR110LK. Dry air, free blowing Dry air, nominal Reg.-air, nominal *) *) adjusted by supplier Cooling air flow External pressure, dry air (115 m3/h) Capacity at 15C, 60% RH (at 230V) 115 m3/h 115 m3 /h 35 m3/h 160 m3/h 0 Pa 9,1 kg/day Electric heater 660 W Fan, process- and cooling air 85 W 230V/50 Motor for gear 3,5 W 230V/50 Nominal power consumption 801 W at 230V Voltage V/50 FURTHER SPECIFICATIONS: Rotor Rotations of rotor Gear Drive belt Pulley DIMENSIONS: LxWxH (see drawing page 4) Weight Silicagel, 0220/50 14 rph B30S, 06/880 R x311x454 mm 22 kg

10 CO 230V, 50 Hz lf) CU audiment technology 7-0 CI I-4 X /St 1St. It nr 0, CY) Cu DIAGRAM, CROILK Industrivej 31A DK-4230 Sk Iskdr c.)

11 x m L -, t'4 1" 5rt1d leisoj AH audiment technology I J u 4 N 0 6

12 Page ELECTRIC COMPONENTS. Refers to electric diagrams : D : Electric Function diagram D : Wiring diagram S : S : Toggle switch, red, dehumidifier on/off Toggle switch, black, dehumidifier man/auto P : Hour counter, HK46G, 230/50 Ml : Fan for process- and cooling air EBM R2E190-A026-12, 85W, 230V/ Capacitor 3A M : Motor for gearbox, Saia UFR12.230, 3,15VA Capacitor 0,12A Gearbox, B30S M : Fan for reg.air EBM R2S175-AB56-01, 53W, 230V/50. El : PTC heater, HRKKO3 6/24, V X : Plug for hygrostat, female, CA3GD (112002): Plug for hygrostat, male, option, CA3LSO9ZS : Protection cover, CAOOSD4 THE INSTALLED ELECTRIC HEATER : The PTC type electric heater is only functioning when air flows through. This is the reason why no thermostats or thermostatic switch is installed, as the function of these components will be regulation of the energy for the electric heater. WARNING : DO NOT TOUCH THE ELECTRIC HEATER WHEN SWITCHED ON, AS IT IS AN UNINSULATED LIVE WIRE. 6.4 REGULATION BY HYGROSTAT. The dehumidifier is prepared for external regulation by a hygrostat. For connection, remove the cabinet top cover. Connect to the terminals 6 & 7 after removing the shunt (the terminals are internal connected a small terminal in the top of the cabinet, inside). The hygrostat should be approved for 230V/3A

13 Page ELECTRIC CONNECTION. The dehumidifier CR110LK is connected 230V, 1N+PE. The dehumidifier is equipped with a 2m cable for the power supply. Power consumption is 1,15 KW - fused by 10A. (see below) SUBJECT : POWER CONSUMPTION & AIRFLOWS. In the electric heater the power consumption is decided by the reg.air flow - which is adjusted by the manufacturer. 7. INSTALLATION. The dehumidifier should be installed indoors, placed on the Enclosed wall bracket. CONNECTION OF DUCTS : 7.1 The process and the cooling air is normally taken from the room, through the air inlet filter. We cannot recommend to connect ducts at the air inlet and for the cooling air outlet. The dry air outlet can be connected some ducting, with regard of the available external pressure. 7.2 The drain to be connected a hose of 12 mm diameter. The hose to be installed draining away from dehumidifier to waste. In general ducts of the same size as placed on the dehumidifier should be used.

14 Page START-UP PROCEDURE. 8.1 ELECTRIC. Before starting-up the dehumidifier, check that all electric connections are made correctly. - Power supply, 230V, 10A external fuse? - PE connection made and in right dimension? - Hygrostat connected (plug) If this is OK, just connect the plug of the supply cable. Switching on: Toggle switch Sl: Red, dehumidifier on/off Toggle switch S2: Black, dehumidifier auto/man (hygrostat) If the dehumidifier don't start (S2 in Pos. Auto): If the humidity (%-RH or dew point) in the air is below the value set on the humidity controller, the dehumidifier don't start (humidity OK). To check: Adjust the controller to lowest possible value, And the dehumidifier will normally start. 8.2 AIR FLOWS. No adjustment of the air flows is necessary. The dry air flow is free blowing 115 m3/h - and should not be reduced (if so, the capacity will decrease). With the electrical settings and air flows adjusted, the dehumidifier will then operate automatically by means of the internal control- and safety functions - controlled by an external hygrostat.

15 Page MAINTENANCE. Dehumidifier CR011,K only needs a minimum of maintenance. All components are service free, which means no lubrication or adjustment. Only three things should be checked under normal operation: - air filter should be replaced often (3-4 times a year). - the rotation of the rotor should be checked once a month. If the rotor rotates during operation, and the fans are operating (= air flow), you are almost sure that the dehumidifier is operating correctly. We nevertheless recommend some periodic verification of the entire dehumidifier, to see if all internal functions are ok and checking of gaskets and moving parts for wear and tear. This will ensure that the capacity is on its maximum, and thus won't waste any energy. 10. TROUBLE SHOOTING If the dehumidifier does not start when electric connected, control the external fuse If the dehumidifier is not operating it is probably the external hygrostat which has broken. This is a normal situation when the desired humidity is obtained. To check : See 9.1, Switching on, above If the desired humidity is not obtained, the problem can be the dehumidifier - or the other parts in the total installation ( room tightness, hygrostat...). To verify this, check: - rotation of rotor? - the dry air should be app. 10C warmer than the inlet main air. If it is cold it could indicate that the rotor is not turning caused by broken drive belt or, the motor has stopped. - by hand feel the temperature of the cooling outlet air and feel the airflow. The temperature is depending on the inlet conditions, but should be 5-6C higher than the inlet process air. If it is cold, the electric heater might be defective.

16 Page SERVICE/REPAIR, 11.1 SAFETY INSTRUCTION. Before opening the dehumidifier, make sure that the electric power is switched off on the main switch (plug disconnected). The dehumidifier CRO1LK is manufactured in the intention of easy cleaning and maintenance, which is important when it is used on building sites. To dismantle the dehumidifier, do like this: 11.2 Access to internal components. Place the dehumidifier on a table. Remove the rear cover, (U-shaped): - Remove the 2 black screws - Remove the 6 screws in the bottom The 2 U-sides of the cover to be twisted in opposite direction for releasing the cover Process air fan, heater, rotor. The plate on which the fan is fixed to be released and pulled out of the cabinet. Now fan, heater and rotor is accessible for replacing. Gearbox for rotor is accessible too (not so easy, but Possible) Reg.air fan. Best way is to pull out the total internal assembly. This is fixed with 4 rivets in the bottem. Remove the rivets and twist the assembly. Disconnecting the cables. Removing the cover above the fan.

17 Page SOUND LEVEL. The sound level is measured according to EN292-2: The dehumidifier is during the measuring of the sound level placed with the top plate 1 m above the floor. Ducts for reg. air is installed and let out of the room, and 2 m dry air duct al00 is installed too. The sound level is then measured 1 m outside the cabinet, and 0,6 m above the floor, and a sound level of 60 db(a) is measured. MANUFACTURED BY : COTES A/S Industrivej 31A DK-4230 SkIskor. Phone Fax Info@cotes.dk *****************

18 audiment technology

19 audiment technology 7N,aanaannaazrxia,iNee:ezegaNiKeavasvezasa lanamnarsvonacmannk, omoolincsmenamacma \ \itnalamwaaruenearmszw munnoimazonnaama% - 73:cmatsnamilacm.. 01:2M1110MESTMa'am cgammimamlaa nzacomanozonli,alamovisaam. armaseannu \almnavaa'au ocmaammonssaami =mem lazzawalaanamacoommun laneemannaziona v[macil enalannuamxwmam cvalannannemtrin tto

20 audiment technology nnsammacmcvazien waavvaavgozzawnerat latimounacmcsomanamo mnaataxamorononvaa \ ia,anowaxsammaamaualk NANNommivsacwx,alacmvarmaisxmaz,%. Nyaclawaicomaaam. Nalmoema mmazl nualugaxmozatt. rwanneszvorim NalanEMICYCWIN% mnammact., maammaauvacmovanaieasa zzamom ervammatmaao IMMENVCIMNE!Zav VC1la'aM NaWMIZMNSEIC:Ikv " MEM 'Ma'acMCIMIZEWa'aa e

COTES ALL-ROUND THE C30 RANGE

COTES ALL-ROUND THE C30 RANGE COTES ALL-ROUND THE C30 RANGE EPERTS IN HUMIDITY MANAGEMENT COTES.COM COTES ALL-ROUND THE C30-RANGE IDEAL FOR USE IN Food industry processing facilities Cold stores Waterworks General humidity management

More information

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www.eipl.co.uk Page 1 of 11 UNPACKING Carefully remove the DD200 dehumidifier unit from its transit box and visually check for signs of transit damage. If there

More information

COTES ALL-ROUND THE C35 RANGE

COTES ALL-ROUND THE C35 RANGE EPERTS IN HUMIDITY MANAGEMENT COTES.COM DEHUMIDIFICATION THE WAY YOU WANT IT C35 DEHUMIDIFIER IDEAL FOR USE IN > PHARMACEUTICAL PRODUCTION FACILITIES > FOOD INDUSTRY PROCESSING FACILITIES > COLD STORES/FREEZER

More information

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www.eipl.co.uk Page 1 of 15 DD200 PACKAGE CONTENTS Item Description Quantity 10502SS-US Dehumidifier 1 3033807 Free plug 1 TPC356 Manual 1 Page 2 of 15 UNPACKING

More information

COTES ALL-ROUND THE C65 RANGE

COTES ALL-ROUND THE C65 RANGE COTES ALL-ROUND THE C65 RANGE EPERTS IN HUMIDITY MANAGEMENT COTES.COM COTES ALL-ROUND THE C65 RANGE IDEAL FOR USE IN Food industry processing Pharmaceutical production Cold stores/freezer facilities Waterworks

More information

COTES ALL ROUND C35E-C35D

COTES ALL ROUND C35E-C35D COTES C35E/C35D OPERATING AND SERVICE HANDBOOK page 1/101 Cotes dehumidifier C35E C35D Manual number: 140712 Revision: B COTES ALL ROUND C35E-C35D How to install, set up, operate and service your Cotes

More information

XXXXXXX EN 1704 INSTALLATION AND OPERATION MANUAL. Desiccant dryer Condair DA 30. Dehumidification and Drying

XXXXXXX EN 1704 INSTALLATION AND OPERATION MANUAL. Desiccant dryer Condair DA 30. Dehumidification and Drying XXXXXXX EN 1704 INSTALLATION AND OPERATION MANUAL Desiccant dryer Condair DA 30 Dehumidification and Drying Thank you for choosing Condair Installation date (MM/DD/YYYY): Commissioning date (MM/DD/YYYY):

More information

Desiccant Dehumidifier MDC

Desiccant Dehumidifier MDC Supplies June Page / Desiccant Dehumidifier MDC Desiccant Dehumidifier MDC Desiccant Dehumidifier MDC June Page / Dehumidifiers are intended to meet industrial and commercial needs for dry air. The heart

More information

Topvex SR03, SR04, SR06 Compact Air Handling Unit

Topvex SR03, SR04, SR06 Compact Air Handling Unit Compact Air Handling Unit GB GB Corrigo ver. no. 1.2-1-00 Manufacturer Our products are manufactured in compliance with applicable international standards and regulations. Systemair AB Industrivägen 3

More information

KK70 Silent. Installation and Operating Instructions L V001

KK70 Silent. Installation and Operating Instructions L V001 KK70 Silent Installation and Operating Instructions 0881100001L02 1502V001 Contents Important information 1 Documentation 3 11 Warnings and symbols 3 12 Notes on copyright 3 2 Safety 4 21 Intended use

More information

Installation, operation and maintenance guide for window models

Installation, operation and maintenance guide for window models Installation, operation and maintenance guide for window models Rev. 2014.06.25 Page 1 of 23 Table of content 2.0.0 GENERAL INFORMATION... 3 2.1.0 PREFACE... 3 2.2.0 AREAS OF USE... 3 2.3.0 INCORRECT USE...

More information

COTES ALL-ROUND THE C105 RANGE

COTES ALL-ROUND THE C105 RANGE COTES ALL-ROUND THE C105 RANGE EPERTS IN HUMIDITY MANAGEMENT COTES.COM COTES ALL-ROUND THE C105-RANGE IDEAL FOR USE IN Pharmaceutical production Cold stores/freezer facilities Waterworks Virtually any

More information

XXXXXXX EN 1704 INSTALLATION AND OPERATION MANUAL. Desiccant dryer Condair DA 65. Dehumidification and Drying

XXXXXXX EN 1704 INSTALLATION AND OPERATION MANUAL. Desiccant dryer Condair DA 65. Dehumidification and Drying XXXXXXX EN 1704 INSTALLATION AND OPERATION MANUAL Desiccant dryer Condair DA 65 Dehumidification and Drying Thank you for choosing Condair Installation date (MM/DD/YYYY): Commissioning date (MM/DD/YYYY):

More information

> ENGLISH VERSION. Instructions HERU 50 HERU / utg 2

> ENGLISH VERSION. Instructions HERU 50 HERU / utg 2 > ENGLISH VERSION Instructions HERU 50 HERU 75 1270100/ utg 2 EC declaration of conformity (as defined by the Machinery Directive 98/37/EEC, appendix 2A) We hereby confirm that HERU 50 and HERU 75 comply

More information

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

Topvex SR 09, 11, Topvex TR Compact Air Handling Units Topvex SR 09, 11, Topvex TR 09-15 Compact Air Handling Units Installation instructions Document in original language 125593 A003 GB Copyright Systemair AB All rights reserved E&OE Systemair AB reserves

More information

Instructions for the fan motor control system, SILVER C

Instructions for the fan motor control system, SILVER C Instructions for the fan motor control system, SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units. The motor control system is

More information

VC-1, VC-1-SL, VC-2-L, VC-2-SL

VC-1, VC-1-SL, VC-2-L, VC-2-SL Pre-Cooling Unit Series VC VC-1, VC-1-SL, VC-2-L, VC-2-SL Instruction Manual Version 1.00.02 Dear customer, we have made up this operating manual in such a way that all necessary information about the

More information

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS Contents Page User instructions 3-5 General 3 Fan installation 3-4 Maintenance 3 Electrical installation 5 Troubleshooting 5 Technical description 6-8 General

More information

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel. DEHUMIDIFICATION 9 CDS 80 FUNCTION The CDS 80 works in accordance with the condensation principle. A fan draws the humid air into the dehumidifier and through an evaporator coil. When passing through the

More information

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes 50-120 1 General The heat exchanger control system is a control system for 380 W step motors

More information

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Instructions for the fan motor control system with integrated wiring terminals SILVER C Instructions for the fan motor control system with integrated wiring terminals SILVER C 1. General The motor control system is used for controlling the type EC, 0.41-10 kw fan motors in the SILVER C units.

More information

Topvex SF02-SF12 Air Handling Unit

Topvex SF02-SF12 Air Handling Unit Topvex SF02-SF12 Air Handling Unit Installation instructions Document in original language 130324 A004 GB Copyright Systemair AB All rights reserved E&OE Systemair AB reserves the rights to alter their

More information

INSTALLATION FB T: +44 (0) F: +44 (0) E: W:

INSTALLATION FB T: +44 (0) F: +44 (0) E: W: INSTALLATION FB 1 Contents User instructions General Fan installation Maintenance Electrical installation Troubleshooting Technical description General Classification Technical specification Manufacturer

More information

Portable honeycomb matrix compact dryer, with loading, combines dehumidifying plastic resin and conveying into a single unit.

Portable honeycomb matrix compact dryer, with loading, combines dehumidifying plastic resin and conveying into a single unit. Portable honeycomb matrix compact dryer, with loading, combines dehumidifying plastic resin and conveying into a single unit. Comet s CCD series compact honeycomb matrix dryers incorporate drying and dehumidifying

More information

XXXXXXX EN 1704 INSTALLATION AND OPERATION MANUAL. Desiccant dryer Condair DA 35. Dehumidification and Drying

XXXXXXX EN 1704 INSTALLATION AND OPERATION MANUAL. Desiccant dryer Condair DA 35. Dehumidification and Drying XXXXXXX EN 1704 INSTALLATION AND OPERATION MANUAL Desiccant dryer Condair DA 35 Dehumidification and Drying Thank you for choosing Condair Installation date (MM/DD/YYYY): Commissioning date (MM/DD/YYYY):

More information

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz GRUNDFOS DATA BOOKLET UPS2 Circulator pumps 50/60 Hz UPS2 Table of contents 1. Product introduction 3 Type key.................................................................................... 3 Performance

More information

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying INDUSTRIAL DEHUMIDIFIERS Advanced range of compressor and desiccant dehumidifiers Dehumidification and drying To room From room Fan Regeneration heater Dry process air Regeneration air Regeneration area

More information

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS XXXXXXX-0 EN 1903 READ AND SAVE THESE INSTRUCTIONS INSTALLATION AND OPERATION MANUAL Desiccant dryer Condair DA 6000-27000 Dehumidification and Drying Thank you for choosing Condair Installation date (MM/DD/YYYY):

More information

SASE BULL 240C. Dust Collection System Manual

SASE BULL 240C. Dust Collection System Manual SASE BULL 240C Dust Collection System Manual www.sasecompany.com 800.522.2606 sales@sasecompany.com Contents 2 Symbols 3 Safety Instructions 3 Intended Use 4 Design of the Bull 240 5 Product Description

More information

Thermo-Sealer. Manual Heat Sealer. User Manual

Thermo-Sealer. Manual Heat Sealer. User Manual Thermo-Sealer Manual Heat Sealer User Manual Thermo-Sealer Contents Page Page Introduction 2 Safety 2 Declaration of conformity 3 Caution and safety signs in accordance with IEC 417 4 Unpacking 4 Technical

More information

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL Thank you for choosing ElectriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference. Visit our

More information

PGD930DES USER MANUAL. VER

PGD930DES USER MANUAL.   VER PGD930DES USER MANUAL www.pridiom.com VER. 1-261112 THANK YOU Thank you for choosing this innovative Pridiom dehumidifier. This instruction manual describes the many benefits and advanced features that

More information

DanVex AD-200 Adsorption air dehumidifier. Operation manual

DanVex AD-200 Adsorption air dehumidifier. Operation manual DanVex AD-200 Adsorption air dehumidifier Operation manual CONTENT Safety instructions...3 Introduction...4 Purpose...4 Design...4 Operation principle...5 Dimensions and weight...5 Installation...6 Technical

More information

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC Technical Concept Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC Technical Concept Plenum Integrated Filter Fan Product Description The Plenum Integrated Filter Fan (PIFF) is a fan filter unit with integrated

More information

User instructions. VA20HD, VA55HD, VA55IND and VA75IND. Commercial wet/dry vacuum cleaners CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

User instructions. VA20HD, VA55HD, VA55IND and VA75IND. Commercial wet/dry vacuum cleaners CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE User instructions VA20HD, VA55HD, VA55IND and VA75IND Commercial wet/dry vacuum cleaners CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE 03-8112-0000 Iss.3 07/08 http://www.truvox.com/products/vacuums/valet_aqua

More information

CONTENTS. Page 1. THE DRYPAC SYSTEM - CUSTOM MADE 1 2. PRINCIPLE OF OPERATION 2 3. CONTROLS 4 4. FLEXIBILITY 6 5. DRYPAC OPTIONS 7

CONTENTS. Page 1. THE DRYPAC SYSTEM - CUSTOM MADE 1 2. PRINCIPLE OF OPERATION 2 3. CONTROLS 4 4. FLEXIBILITY 6 5. DRYPAC OPTIONS 7 CONTENTS Page 1. THE DRYPAC SYSTEM - CUSTOM MADE 1 2. PRINCIPLE OF OPERATION 2 3. CONTROLS 4 4. FLEXIBILITY 6 5. DRYPAC OPTIONS 7 6. CONSTRUCTION / MATERIALS 8 7. DIMENSIONS 8 8. LAYOUT 12 9. PRINCIPLE

More information

TFV 900 OPERATING MANUAL RADIAL FAN TRT-BA-TFV900-TC-001-EN

TFV 900 OPERATING MANUAL RADIAL FAN TRT-BA-TFV900-TC-001-EN TFV 900 EN OPERATING MANUAL RADIAL FAN TRT-BA-TFV900-TC-001-EN Table of contents Notes regarding the operating manual... 1 Safety... 2 Information about the device... 3 Transport and storage... 4 Start-up...

More information

ML/MLT. User s Manual 17E-30E. Desiccant dehumidifiers ML17E-MLT30E with electric heater for reactivation

ML/MLT. User s Manual 17E-30E. Desiccant dehumidifiers ML17E-MLT30E with electric heater for reactivation User s Manual ML/MLT 17E-30E Desiccant dehumidifiers ML17E-MLT30E with electric heater for reactivation Applies to all units manufactured from week 37, 2005 190TEN-1041revC Munters Europe AB 2005 Table

More information

Instructions manual DEHUMID HP50

Instructions manual DEHUMID HP50 Instructions manual DEHUMID HP50 Table of contents 1. Unpacking 3 2. Intended use 3 3. Disposal 3 4. Safety instructions 3 5. Functional principle 4 6. Automatic defrosting system 4 7. Set up and transportation

More information

Bruksanvisning Directions for use

Bruksanvisning Directions for use Bruksanvisning Directions for use LPKB 125 B/B-r, LPKB 160 K/K-r, LPKB 200 B/B-r, LPKB 200 K/K-r LPKBI 125 B/B-r, LPKBI 160 K/K-r, LPKBI 200 B/B-r, LPKBI 200 K/K-r SVENSK/ENGLISH VERSION ENGLISH This directions

More information

A/C-HEATER SYSTEM - MANUAL

A/C-HEATER SYSTEM - MANUAL A/C-HEATER SYSTEM - MANUAL 1986 Isuzu Trooper II 1986 A/C-HEATER SYSTEM Isuzu A/C-Heater Systems - Manual P UP, Trooper II * PLEASE READ THIS FIRST * CAUTION: When discharging air conditioning system,

More information

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz VA 150 A, VA 150 P WINDOW EXTRACT FAN Installation and Wiring Instructions VA150 P STOCK Ref: 152110B VA150 A STOCK Ref: 153110B 220-240V/1/50Hz READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS PLEASE

More information

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual DOMEKT ReGO 400VE(W)-B Series Air Handling Units EN Content Safety Requirements...3 Transportation...3 Brief Description of the Unit...5 Installation...6 Maintenance...11 Technical Information......13

More information

TTV 4500 / TTV 4500 HP / TTV 7000

TTV 4500 / TTV 4500 HP / TTV 7000 TTV 4500 / TTV 4500 HP / TTV 7000 EN OPERATING MANUAL AXIAL FAN TRT-BA-TTV4500-4500HP-7000-TC-003-EN Table of contents The current version of the operating manual can be found at: Notes regarding the operating

More information

AZN ATEX INSTALLATION AND MAINTENANCE

AZN ATEX INSTALLATION AND MAINTENANCE ZerAx AZN ATEX INSTALLATION AND MAINTENANCE 924714-0 English 924714-0 GB ZerAx axial flow fans type AZN ATEX Installation and maintenance 1. Application 2. Handling 2.1 Marking 2.2 Weight 2.3 Temperature

More information

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models: INSTALLATION, OPERATION AND MAINTENANCE MANUAL BHW MEDIUM STATIC PRESSURE DUCTABLE TYPE Models: 174 205 358 410 515 720 724 Cooling capacities from 3,1 to 25 KW Heating capacities from 4,5 to 55,5 KW Thank

More information

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59 SOUND-INSULATED FAN OPERATION MANUAL _v.1(2)-en.indd 1 10.08.2015 15:20:59 CONTENT Introduction 3 General 3 Safety rules 3 Transport and storage requirements 3 Manufacturer's warranty 3 Fan design 4 Delivery

More information

Instruction manual. Dehumidifier AD 810. valid: page 1 of 14

Instruction manual. Dehumidifier AD 810. valid: page 1 of 14 Instruction manual Dehumidifier AD 810 valid: 10-2010 page 1 of 14 Index 1. Illustration 1.1. View from the rear AD 810 3 2. General advice 3 3. Mode of functioning 4 4. Safety 5 5. Installation and transport

More information

Bona DCS70/Portable DCS Manual and safety instruction

Bona DCS70/Portable DCS Manual and safety instruction Bona DCS70/Portable DCS Manual and safety instruction WARNING Read the instructions manual before using the machine AMO530002 AMO530005 Bruksanvisning i original v1.1 TECHNICAL DATA Motor type: DCS70 Portable

More information

HOTLINE:

HOTLINE: You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 5 years and beyond without a major service. Please therefore

More information

FREE STAR INDUSTRIAL DEHUMIDIFIER USERS MANUAL

FREE STAR INDUSTRIAL DEHUMIDIFIER USERS MANUAL FREE STAR INDUSTRIAL DEHUMIDIFIER USERS MANUAL www.ebacusa.com Page 1 of 13 UNPACKING Thank you for deciding to purchase an Ebac dehumidifier. Like the many tens of thousands of people who have already

More information

Owner s Manual Phoenix 1200 Desiccant Dehumidifier

Owner s Manual Phoenix 1200 Desiccant Dehumidifier PO Box 8680 Madison, WI 53708 Owner s Manual Phoenix 1200 Desiccant Dehumidifier Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix 1200 Portable Desiccant Dehumidifier

More information

DanVex AD-550 Adsorption air dehumidifier. Operation manual

DanVex AD-550 Adsorption air dehumidifier. Operation manual DanVex AD-550 Adsorption air dehumidifier Operation manual CONTENT Safety instructions...3 Introduction...4 Purpose...4 Design...4 Control board (introduction)...5 Operation principle...6 Dimensions and

More information

DryFan 8. Pro. Pro INTERNATIONAL PATENT PENDING DEHUMIDIFIER USER MANUAL DryFan 8 (white) DryFan 12 (white)

DryFan 8. Pro. Pro INTERNATIONAL PATENT PENDING DEHUMIDIFIER USER MANUAL   DryFan 8 (white) DryFan 12 (white) DEHUMIDIFIER using DryFan Technology INTERNATIONAL PATENT PENDING WWW.ECORPRODUCTS.COM WWW.ECORPRODUCTS.COM DryFan 8 Pro WHITE STAINLESS STEEL DEHUMIDIFIER USER MANUAL DryFan 8 (white) DryFan 12 (white)

More information

Applications Damage service Building drying Water works Dry storing FEATURES

Applications Damage service Building drying Water works Dry storing FEATURES MOBILE DEHUMIDIFIER Function The is a robust, cost-effective and energy-efficient, reliable mobile dehumidifier. It works in accordance with the condensation principle. A fan draws the humid air into the

More information

Operating instructions

Operating instructions ebm-papst Mulfingen GmbH & Co. KG Bachmühle D-74673 Mulfingen Phone +49 (0) 793-0 Fax +49 (0) 793-0 info@de.ebmpapst.com www.ebmpapst.com CONTENTS. SAFETY REGULATIONS AND NOTES. Levels of hazard warnings.

More information

1592P01. for liquids in piping DN

1592P01. for liquids in piping DN 1 594 1592P01 Flow switch for liquids in piping DN 20 200. QVE1901 Contact load / switching capacity: max. AC 230 V, 1 A, 26 VA max. DC 48 V, 1 A, 20 W Nominal pressure PN25 Manual setting of contact type

More information

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N V-SERIES Air Conditioner VA08 Model INSTRUCTION MANUAL Rev. F P/N 90164959 TABLE OF CONTENTS Warranty and Return Policy...2 RECEIVING THE AIR CONDITIONER...3 HANDLING AND TESTING THE AIR CONDITIONER...3

More information

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER USER MANUAL SILENT16 PORTABLE AIR CONDITIONER Thank you for choosing electriq Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference. Visit our

More information

for Ultima-Tig and for Ultima-Tig-Cut

for Ultima-Tig and for Ultima-Tig-Cut User manual for Ultima-Tig and for Ultima-Tig-Cut Inelco Grinders A/S, Industrivej 3, DK-9690 Fjerritslev, Denmark 1/7 EU statement of compliance Manufacturer: INELCO GRINDERS A/S Industrivej 3 9690 Fjerritslev

More information

USER-MANUAL Tamson Cool Cube Immersion Cooler

USER-MANUAL Tamson Cool Cube Immersion Cooler USER-MANUAL Tamson Cool Cube Immersion Cooler Page 1/14 1 SAFETY AND WARNINGS... 3 2 WARRANTY... 3 3 DISCLAIMER... 3 4 PRECAUTIONS AND HAZARDS... 4 5 INSTALLATION... 4 5.1 IMPORTANT... 4 6 USE... 5 7 WHAT

More information

HEAT RECOVERY VENTILATOR

HEAT RECOVERY VENTILATOR HEAT RECOVERY VENTILATOR HRV H 00 ERV H 00 HRV H 300 ERV H 300 EN OPERATION MANUAL HRV /ERV H 00(300) www.blaubergventilatoren.de CONTENTS Application... Delivery set...3 Unit designation key...3 Basic

More information

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20 INSTALLATION, OPERATION AND MAINTENANCE Ariterm Hybrid 20 TABLE OF CONTENTS General...3 Installation... 4-5 Dimensions - with flue gas exhauster...6 Dimensions - without flue gas exhauster...7 Pipe installations...8

More information

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT Made in Italy Air Conditioning High Wall Fan Coil -ECM QUALITY MANAGEMENT SYSTEMS ISO 9001 - Cert. n 0545/5 www.eurovent-certification.com www.certiflash.com ENVIRONMENTAL COMFORT CONTENTS Introduction

More information

Bench-Top Vacuum Oven with 28 segments programmable controller

Bench-Top Vacuum Oven with 28 segments programmable controller Bench-Top Vacuum Oven with 28 segments programmable controller DZF-6000F Series Vacuum Oven MTI Corporation www.mtixtl.com 1 Safety notes DZF Vacuum Oven Please read the following safety notes carefully

More information

ULTRAFLOW 54 DN

ULTRAFLOW 54 DN Data sheet ULTRAFLOW 54 DN150-300 For flow from 150 m³/h up to 1000 m³/h Ultrasonic flow sensor Compact design Static meter, no moving parts Large dynamic range No wear High accuracy Longevity MID-2004/22/EC

More information

STR-600 Impact Dryer

STR-600 Impact Dryer STR-600 Impact Dryer 1. STR-600 Main Features The STR-600 is designed for moisture damage drying of targeted areas. The device can be used for drying various stone-based materials, such as concrete, brick

More information

10 & 12 Ventilator. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

10 & 12 Ventilator. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit DC Heat Recovery Unit MVHR Wholehouse heat recovery unit Stock Ref. N DC Heat Recovery Unit MVHR 443423 Installation, Maintenance & Users Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

More information

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S USER S MANUAL Heat (Energy) Recovery Ventilator Vents Frigate HRV 120 S Vents Frigate ERV 120 S 2 Frigate HRV(ERV) 120 S CONTENT Introduction... 3 Application... 3 Delivery set... 3 Unit designation key...

More information

Mobile Type Air Conditioner

Mobile Type Air Conditioner Mobile Type Air Conditioner 1. Features 2. Specification 3. Wiring diagram 4. Trouble shooting 5. Electronic function 36 1. Features 1.1The currently manufactured mobile air conditioners include the following

More information

VACUUM EXTRACTOR MODEL NO: CWVE1 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0916

VACUUM EXTRACTOR MODEL NO: CWVE1 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: GC0916 VACUUM EXTRACTOR MODEL NO: CWVE1 PART NO: 6471168 OPERATING & MAINTENANCE INSTRUCTIONS GC0916 INTRODUCTION Thank you for purchasing this CLARKE Workshop Vacuum Extractor. Before attempting to use this

More information

HR200WK Through the wall Heat Recovery Ventilator

HR200WK Through the wall Heat Recovery Ventilator HR200WK Through the wall Heat Recovery Ventilator Installation and Maintenance Instructions Stock Ref No:- HR200WK 14120020 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE

More information

High Output Vacuum/Pressure Pump

High Output Vacuum/Pressure Pump High Output Vacuum/Pressure Pump User Guide Catalogue Numbers: WP62 115 60 (115 V, 60 Hz) WP62 220 50 (230 V, 50 Hz, 1.1 A) WP62 100 60 (100 V, 50/60 Hz) Notice The information in this document is subject

More information

Operating Instructions

Operating Instructions Operating Instructions Typ TEKA CAREMASTER TEKA Absaug- und Entsorgungstechnologie GmbH Industriestraße 13 D-46342 Velen Postfach 1137 D-46334 Velen Tel.: +49 (0) 2863 9282-0 Fax: +49 (0) 2863 9282-72

More information

ENGLISH. ComDry M160L Dehumidifier. User manual from serial no T-M160L-A1808

ENGLISH. ComDry M160L Dehumidifier. User manual from serial no T-M160L-A1808 ENGLISH ComDry M160L Dehumidifier User manual from serial no. 20001 T-M160L-A1808 Copyright 2018 Munters Europe AB Original instructions Read these instructions before using the dehumidifier. Table of

More information

INSTRUCTIONS RHS 700. Recovery, Recycling, Evacuation and Charging Station RHS 700

INSTRUCTIONS RHS 700. Recovery, Recycling, Evacuation and Charging Station RHS 700 A GRAMKOW A/S Augustenborg Landevej 19 DK-6400 Sønderborg Denmark A/S Reg. No. 17 12 31 Telephone: 45 74 12 36 36 Telefax: 45 74 43 36 46 Telex: 5 23 18 Bank: Den Danske Bank, No. 32 27 INSTRUCTIONS Recovery,

More information

USER MANUAL AND TECHNICAL MANUAL

USER MANUAL AND TECHNICAL MANUAL USER MANUAL AND TECHNICAL MANUAL Kanmed Universal Warming Cabinets Kanmed Blanket Warming Cabinets Kanmed Combination Cabinet GE-2300-070 / 4 2014-05-12 NOTE: This manual contains important information

More information

DOMEKT ReCU 400VE(W)CF-EC-C4 Series Air Handling Units Installation and Maintenance Service Manual

DOMEKT ReCU 400VE(W)CF-EC-C4 Series Air Handling Units Installation and Maintenance Service Manual DOMEKT ReCU 400VE(W)CF-EC-C4 Series Air Handling Units Installation and Maintenance Service Manual EN Content Safety Requirements...3 Transportation...3 Brief Description of the Unit...5 Installation...6

More information

Compressed air preparation Compressed air storage Moisture management. Catalog #1

Compressed air preparation Compressed air storage Moisture management. Catalog #1 Compressed air preparation Compressed air storage Moisture management Catalog #1 This Catalogue is valid from May 2015. All previous catalogues lose their validity with the publication of the new catalogue.

More information

QZHW Fan Coil Unit. Key features. Specifications

QZHW Fan Coil Unit. Key features. Specifications Key features High wall installation Cooling ( pipes) Low noise level Electrical heating coil ECM version for low energy consumption QZHW is a high wall fan coil unit available in sizes and many different

More information

Tempest TP420/180 Electric Pressure Washer

Tempest TP420/180 Electric Pressure Washer Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

ISCG90SS _03 ISCG90SS

ISCG90SS _03 ISCG90SS ISCG90SS 60900355_03 ISCG90SS GB IE [01] x 1 [02] x 1 [03] x 1 [04] x 8 [05] x 1 [06] x 4 [07] x 1 [08] x 1 [09] x 1 [10] x 4 [11] x 4 [12] x 1 [13] x 4 (6x70mm) [14] x 8 (6.3x17x2mm) 1 : 1 [15] x 4 (3.9x18mm)

More information

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor Labkotec UK Ltd Adminicle House 1 Lumb Lane Audenshaw Manchester M34 5WH GREAT BRITAIN Tel: 0844 3350 477 Fax: 0161 4281 179 E-mail: info@labkotec.co.uk 10.8.2012 Internet: www.labkotec.co.uk 1/13 OilSET-1000

More information

Operating manual 1 SAFETY REGULATIONS AND INFORMATION. Original operating manual INDEX 2218 F/2TDH4P

Operating manual 1 SAFETY REGULATIONS AND INFORMATION. Original operating manual INDEX 2218 F/2TDH4P Operating manual 2218 F/2TDH4P 1 SAFETY REGULATIONS AND INFORMATION Read the operating manual carefully before commencing work at the product. Pay attention to the following warnings to avoid risk to persons

More information

CENTRIFLOW 3D. >> Installation and Maintenance. air comfort. CentriFlow 3D

CENTRIFLOW 3D. >> Installation and Maintenance. air comfort. CentriFlow 3D CENTRIFLOW 3D Plug fan GMEC >> Installation and Maintenance air comfort CentriFlow 3D 2 Plug Fan CentriFlow 3D GMEC Installation and Maintenance Important Information, Safety notes, Technical Description

More information

Heat and energy recovery ventilators

Heat and energy recovery ventilators Description is recommended for use in residential houses with max. area of 200m2. The most important key features of : Heat recovery up to 95% according to EN 308 - TUV SUD Plastic counterflow heat exchanger

More information

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80 EN OPERATING MANUAL OIL HEATER TRT-BA-IDE20-30-50-60-80-TC-001-EN Table of contents Information on the use of this manual... 1 Scope of delivery... 1 General safety...

More information

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

COMPACT PORTABLE AIR CONDITIONER USER MANUAL COMPACT PORTABLE AIR CONDITIONER USER MANUAL Thank you for choosing ElectriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference. Visit our page

More information

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference. SAFETY INSTRUCTIONS Important! Carefully

More information

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1

Lodam Compressor Protection Module. Technical manual. Version 3.0 SE-G1 Lodam Compressor Protection Module Technical manual Version 3.0 SE-G1 Contents 1. Read this first... 4 1.1. Reading instructions... 4 1.2. User manual... 4 1.3. Safety... 4 2. General... 5 3. Definitions...

More information

HSGM Heißschneide-Geräte

HSGM Heißschneide-Geräte Operating Instructions Heat cutting machine Model HSG-00 General information These Operating Instructions belong to this product. They contain important information about commissioning and operation. Important

More information

GLEB Kitchen exhaust fan

GLEB Kitchen exhaust fan GLEB Kitchen exhaust fan Installation and Maintenance??.1.2013 Contents 1. Important information 2. Safety notes 3. Technical description 4. Transport 5. Mounting instructions 6. Commissioning 7. Maintenance

More information

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www.eipl.co.uk Page 1 of 12 CD30 PACKAGE CONTENTS Item Description Quantity 1133500 Dehumidifier 1 3014338 PVC tube 12mm I/D 3 M 3086101 Jubilee clip

More information

Evap WTW INSTALLATION INSTRUCTIONS D

Evap WTW INSTALLATION INSTRUCTIONS D Evap WTW INSTALLATION INSTRUCTIONS (English) WWW.BRINKAIRFORLIFE.NL 614796-D English (EN) Installation instructions Humidifier for central ventilation with heat recovery KEEP WITH THE PRODUCT This product

More information

DEHUMIDIFIERS & VENTILATORS

DEHUMIDIFIERS & VENTILATORS 2015/2016 DEHUMIDIFIERS & VENTILATORS MCS GROUP www.mcsworld.com I CHOOSE MASTER DEHUMIDIFIERS. WHY? SAVE TIME dehumidifiers speed up many renovation and construction works REDUCE THE INVESTMENT COSTS

More information

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER

More information

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL CONTENT 3 Introduction 3 General 3 Safety rules 3 Storage and transportation rules 3 Manufacturer s warranty 4 Fan design 4 Delivery set 5 Technical data

More information

MeacoDry ABC Range Dehumidifiers

MeacoDry ABC Range Dehumidifiers MeacoDry ABC Range Dehumidifiers Thank you for choosing Meaco, we really do appreciate it INSTRUCTION MANUAL [EN] MeacoDry ABC range SAFETY INFORMATION ATTENTION This dehumidifier must not be used in rooms

More information

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket MRXBOX95-WH1 Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance The EMC Directive 2004/108/EC The Low Voltage Directive 2006/95/EC 1.0 Introduction The unit must

More information