UNICEF SD Technical basis for UNICEF procurement. Immunization refrigerators industry consultation October, 2016 Copenhagen

Size: px
Start display at page:

Download "UNICEF SD Technical basis for UNICEF procurement. Immunization refrigerators industry consultation October, 2016 Copenhagen"

Transcription

1 UNICEF SD Technical basis for UNICEF procurement Immunization refrigerators industry consultation October, 2016 Copenhagen

2 OUTLINE Specifications and TPPs Current Vs previous PQS specifications Vs TPP CCEOP Requirements Tender approach Tender eligibility UNICEF approach to country procurement requests. Questions and answer

3 TERMS USED IN THIS PRESENTATION Current specifications WHO specifications that incorporated TPP requirement, (amended in 2016). Previous specifications WHO specifications, prior to amendment in 2016, which has been used to prequalify products TPP ( Target Product Profile) WHO/ PQS document that lists the principal desired features of a product category intended for future PQS prequalification.

4 OVERVIEW OF SPECIFICATIONS AND TPPS REFRIGERATORS VF Mains (ICE PACKS) 1 TPP (29 Aug 2016) Battery Drive WPF Refrigerators Solar Direct Drive without battery 2 TPP Direct Drive with ancillary battery WPF Absorption No TPP Solar power systems 1 TPP WPF = Water pack freezer R. OR COMB = Refrigerator or Comb. Ref. water pack freezer VF = Vaccine or Comb. Icepack freezer

5 OVERVIEW OF SPECIFICATIONS AND TPPS REFRIGERATORS VF Mains (ICE PACKS) 1 TPP (29 Aug 2016) Battery Drive WPF Refrigerators Solar Direct Drive without battery 2 TPP Direct Drive with ancillary battery WPF Absorption No TPP Solar power systems 1 TPP WPF = Water pack freezer R. OR COMB = Refrigerator or Comb. Ref. water pack freezer VF = Vaccine or Comb. Icepack freezer

6 TPPS FOR MAINS POWERED REFRIGERATORS TPP for Mains powered refrigerators Acceptable temp. range Freeze protection classification Gross storage capacity Holdover time Hot zone Rated min ambient temp Moderate zone Vaccine net storage cap Vaccine storage capacity (30 liter stage) Humidity control Ambient temperature operation (10-43 degree) Refrigerant Input voltage and frequency Temperature monitoring Type Type User centered design feature (2019) Control panel (2017) Provision for loose vials (2017) Service provision ( 10 year) Instructions Shipping and storage conditions Accessories ( Voltage stabilizers) Spare parts

7 SPECIFICATIONS MAINS POWERED REFRIGERATOR # Previous specifications Current PQS specifications 1 No classification Freeze protection classification 2 No requirement Humidity control 3 Min amb temp as high as +25 were acceptable Ambient temperature operation (10 43) 4 Both R134a and R600a are acceptable Preference is given to R600a Grade A, user-independent freeze protection (UIFP), Grade B, userdependent freeze protection (UDFP), Grade C, user-dependent freeze protection (UDFP) Condensate and defrost drainage must be provided in all refrigerator and freezer compartments All must be suitable for operation in the hot zone (+43 C) and at a minimum rated ambient temperature of +10 C or lower whilst maintaining the acceptable temperature range in the vaccine storage compartment. Existing appliances with HCFC refrigerants including R134a will be phased out over a transition period of four years from the issue date of this publication. Refrigerant Mains powered 33% 61% Not indicated R290 R134a R600a Operating temperature Mains powered 33% 67% PQS as of September Mains powered refrigerators 22 fully complaint with CCEOP PQS as of September suppliers 61% uses R134a and lower Others

8 SPECIFICATIONS MAINS POWERED REFRIGERATOR # Previous specifications Current PQS specifications 1 Input voltage and frequency Input voltage and frequency 2 No classification Type , Type Limited requirement More detailed Instructions requirement volt 50/60 Hz and volt 50/60 Hz options are to be offered. Temperature monitoring device required is a prequalified disposable 30 day temperature logger, with or without an external sensor lead, located in an integrated holder within the vaccine storage compartment. Instructions PQS stickers Printed. User, installation and maintenance instructions

9 SPECIFICATIONS MAINS POWERED REFRIGERATOR # Previous specifications Current PQS specifications 1 Improved requirement on shipping and storage conditions 2 Voltage stabilizer not a requirement Voltage stabilizer is a requirement accessories 3 Limited requirement Spare parts, More requirement Bulb and capillary thermostat not acceptable Every appliance must be provided with either an integrated or a standalone voltage stabilizer. The voltage stabilizer must be certified by WHO PQS as complying with WHO/PQS/E007/VS01.2. Based on product design and requirements the type and quantity of spare parts, basic installation tools/supplies, user and technician maintenance manuals must be determined and agreed upon in advance of order placement. Thermostat must be designed so that it cannot be adjusted by the user. A means for adjustment by a technician is acceptable provided the device is protected from user interference (e.g. by location within the appliance cabinet). Alternatively, programmable thermostats may be passwordprotected. Bulb and capillary tube thermostats are not acceptable.

10 OVERVIEW OF CURRENT SPECIFICATIONS AND TPPS REFRIGERATORS VF Mains (ICE PACKS) 1 TPP (29 Aug 2016) Battery Drive WPF Refrigerators Solar Direct Drive without battery 2 TPP Direct Drive with ancillary battery WPF Absorption No TPP Solar power systems 1 TPP WPF = Water pack freezer R. OR COMB = Refrigerator or Comb. Ref. water pack freezer VF = Vaccine or Comb. Icepack freezer

11 SPECIFICATIONS VS TPP - SDD Included in current specification User feedback channels and information sharing with WHO will feed in to new TPPS

12 SPECIFICATIONS SOLAR POWERED REFRIGERATOR # Previous specifications Current PQS specifications 1 Capillary tube thermostat were acceptable 2 No requirement Humidity control 3 Min amb. temp as high as +25 were acceptable No bulb and capillary tube thermostat Minimum rated ambient temperature operation Thermostat must be designed so that it cannot be adjusted by the user. A means for adjustment by a technician is acceptable provided the device is protected from user interference (e.g. by location within the appliance cabinet). Alternatively, programmable thermostats may be passwordprotected. Bulb and capillary tube thermostats are not acceptable. Condensate and defrost drainage must be provided in all refrigerator and freezer compartments All must be suitable for operation in the hot zone (+43 C) and at a minimum rated ambient temperature of +10 C or lower whilst maintaining the acceptable temperature range in the vaccine storage compartment. 19% Operating temperature Solar 81% and lower Others PQS as of September Mains powered refrigerators 30 complies with requirement 25 fully complaint with CCEOP 5 Solar Battery Drive refrigerators

13 SPECIFICATIONS SOLAR POWERED REFRIGERATOR # Previous specifications Current PQS specifications 1 Both R134a and R600a are acceptable Preference is given to R600a 2 Not a requirement but has been supplied Plug and Play electrical components 3 Not a requirement Power switch 4 Limited requirement More detailed Instructions requirement The appliance is to be equipped with a locking female and male coupler system ( plug and play ) that is compatible with the solar array interconnection cable and polarity. Each appliance to provide an on and off power switch that is readily accessible to the user either on the outside of the appliance cabinet or in a wall-mounted switch within 1 meter of the appliance. Refrigerant Mains powered PQS as of September % 37 Mains powered refrigerators 29 R600a 81% 8 R134a 3 SDD with ancillary battery R134a R600a

14 SPECIFICATIONS SOLAR POWERED REFRIGERATOR # Previous specifications Current PQS specifications 1 Vaccine freeze protection classification 2 Type 1 temp monitor 3 Technical /maintenance kit 4 Operation and maintenance sticker 5 Detailed shipping and storage conditions 6 Detailed spare part inclusion

15 OVERVIEW OF CURRENT SPECIFICATIONS AND TPPS REFRIGERATORS VF Mains (ICE PACKS) 1 TPP (29 Aug 2016) Battery Drive WPF Refrigerators Solar Direct Drive without battery 2 TPP Direct Drive with ancillary battery WPF Absorption No TPP Solar power systems 1 TPP WPF = Water pack freezer R. OR COMB = Refrigerator or Comb. Ref. water pack freezer VF = Vaccine or Comb. Icepack freezer

16 Selection of equipment

17 17

18 ABSORPTION REFRIGERATORS Absorption refrigerators There are two specifications for absorption systems Water pack freezer Refrigerator or combined refrigerator of freezer No pre qualified product No TPP Not CCEOP eligible. Solar Battery Drive refrigerators There is one specification 5 pre qualified products No TPP Not CCEOP eligible

19 OVERVIEW OF CURRENT SPECIFICATIONS AND TPPS REFRIGERATORS VF Mains (ICE PACKS) 1 TPP (29 Aug 2016) Battery Drive WPF Refrigerators Solar Direct Drive without battery 2 TPP Direct Drive with ancillary battery WPF Absorption No TPP Solar power systems 1 TPP WPF = Water pack freezer R. OR COMB = Refrigerator or Comb. Ref. water pack freezer VF = Vaccine or Comb. Icepack freezer

20 SOLAR POWER SUPPLY SYSTEMS Array support structure ( In line with UNCIEF specs) Power switch ( In line with UNCIEF specs) At least one method to isolate (disconnect) the appliance from the solar power system must be supplied User maintenance kit (In line with UNICEF requirement) All sites are to be supplied with one complete installation kit. All sites are to be supplied with one complete user maintenance kit consisting of all necessary operations and maintenance tools as proposed by Legal Manufacturer. installations tools as proposed by Legal Manufacturer. Generalized roof/ground mounts with adjustable tilt angles and optional pole mounts are to be offered by all manufacturers. The combined array structure and photovoltaic panel assembly must be designed to withstand wind loads of 200 kg per square meter and supplied with supporting wind load calculations.

21 SOLAR POWER SUPPLY SYSTEMS The array structure package is to be supplied with a complete set of theft deterrent fasteners including any special tool or bit required. Spare parts are to be provided in kit form for storage in appropriate quantities at central or regional level in the purchasing country, as agreed with the purchasing agency. determined and agreed upon in advance of order placement

22 CCEOP requirements

23 CCEOP REQUIREMENTS

24 CCEOP REQUIREMENTS

25 CCEOP REQUIREMENTS

26 CCEOP REQUIREMENTS

27 Tender eligibility?

28 Pipeline devices Existing devices PQS-listed devices WHICH PRODUCT CATEGORIES ARE ELIGIBLE FOR TENDER Market Consideration by UNICEF in 2016 tender Eligibility to tender Catalogue referencing PIS-listed devices Depletion from catalogue Keep open-ended LTA for spare parts and tools Devices meeting previous PQS specifications Devices meeting current PQS specifications CCEOP-eligible devices (meeting current PQS specs + subset of TPPs 2017, e.g. UIFP) Expression of preference for better technologies (e.g. UIFP, 10-yr warrantee criteria evolving overtime): reservation of right to deplete from catalogue anytime when PQS-listed Automatic depletion from catalogue when no longer PQSlisted Expression of preference for better technologies (e.g. UIFP, 10-yr warrantee criteria evolving overtime): reservation of right to deplete from catalogue anytime In catalogue Devices meeting current PQS specifications Conditional awards pending PQS approval when entering the market CCEOP-eligible devices (meeting current PQS specs + subset of TPPs 2017) Devices meeting all or part of TPPs 2017 and potentially 2019 Conditional awards pending PQS approval when entering the market UNICEF 28

29 Pipeline devices Existing devices PQS-listed devices APPROACH TO COUNTRY REQUESTS FOR PROCUREMENT Market Consideration or country s request for procurement by UNICEF-SD PIS-listed devices Devices meeting previous PQS specifications Procurement conditional to justifications Advise countries on available alternatives better suited to their needs (e.g. CCEOP-eligible products) Proceed with original order only in case of small volumes, essential spares, or strong justification. Devices meeting current PQS specifications CCEOP-eligible devices (meeting current PQS specs + subset of TPPs 2017, e.g. UIFP) Advise countries on available alternatives better suited to their needs (e.g. CCEOP-eligible products) Proceed with original or amended order Proceed with original order Devices meeting current PQS specifications CCEOP-eligible devices (meeting current PQS specs + subset of TPPs 2017) n/a all devices must become PQS approved to be eligible to procurement Devices meeting all or part of TPPs 2017 and potentially 2019 UNICEF 29

30 Technical Mandatory requirements UNICEF 30

31 SOLAR POWER SUPPLY SYSTEMS A/Technical evaluation of Mandatory Requirements - PQS compliance Each Proposal must contain. - A completed Technical answering Sheet. - A valid WHO PQS certificate for products offered. - Supporting documentation on the system sizing methodology and data used. - Hardcopies of manuals UNICEF 31

32 SOLAR POWER SUPPLY SYSTEMS In addition to complying with the requirements; the parameters that shall be considered for evaluation of the solar systems include, but are not limited to consideration of: Provision of quick assembly of interconnection cables to cabinet/array-this shall be plug and play as a standard feature) Reference period insolation- 3.5 KWh/m 2 /24hours- This irradiance to be used as the default value for entry for the annual monthly average while sizing a system Documentation of the system sizing approach shall be submitted together with the bids for evaluation. Documentation proof of solar panel conformity to international recognized standard Conformity to transportation environment and packaging (revised PQS requirement) UNICEF 32

33 Thank you

VACCINE CARRIERS AND COLD BOXES

VACCINE CARRIERS AND COLD BOXES SUPPLY DIVISION COLD CHAIN SUPPORT PACKAGE PROCUREMENT GUIDELINES VACCINE CARRIERS AND COLD BOXES VACCINE CARRIERS AND COLD BOXES Procurement Guidelines Vaccine Carriers and Cold Boxes Key information

More information

TITLE: Ice-lined Refrigerator or Combined Refrigerator-Icepack Freezer, Compression Specification reference:

TITLE: Ice-lined Refrigerator or Combined Refrigerator-Icepack Freezer, Compression Specification reference: Version: Draft Effective date: Page: 1 of 6 PQS performance specification WHO/XXX Original: English Distribution: General TITLE: Ice-lined Refrigerator or Combined Refrigerator-Icepack Freezer, Compression

More information

PQS Independent type-testing protocol

PQS Independent type-testing protocol PQS Independent type-testing protocol WHO/PQS/E03/RF05-VP.1 Original: English Distribution: General TITLE: Refrigerator or combined refrigerator-icepack freezer: compression-cycle. Solar direct drive without

More information

SOLAR VACCINE REFRIGERATOR TCW 2000 SDD PRODUCT DESCRIPTION. Icelined refrigerator and icepack freezer

SOLAR VACCINE REFRIGERATOR TCW 2000 SDD PRODUCT DESCRIPTION. Icelined refrigerator and icepack freezer SOLAR VACCINE REFRIGERATOR TCW 2000 SDD Icelined refrigerator and icepack freezer SKU: TCW 2000 SDD Categories: Cold Chain, Solar Vaccine Refrigerators PRODUCT DESCRIPTION The new TCW2000 SDD (Solar Direct

More information

PQS performance specification

PQS performance specification PQS performance specification WHO/PQS/E003/FZ01.2 Original: English Distribution: General TITLE: Vaccine freezer or combined vaccine and water-pack freezer: compression-cycle Specification reference: E003/FZ01.2

More information

PQS performance specification

PQS performance specification PQS performance specification WHO/PQS/E003/RF06.1 Original: English Distribution: General TITLE: Refrigerator or combined refrigerator and water-pack freezer: compression-cycle. Solar direct drive with

More information

PQS performance specification

PQS performance specification PQS performance specification WHO/PQS/E003/RF03.2 Original: English Distribution: General TITLE: Ice-lined refrigerator or combined refrigerator and water-pack freezer: compression cycle Specification

More information

PQS performance specification

PQS performance specification PQS performance specification WHO/PQS/RF04.2 Original: English Distribution: General TITLE: Refrigerator or combined refrigerator and water-pack freezer: compression-cycle. For solar powered rechargeable

More information

PQS Independent type-testing protocol

PQS Independent type-testing protocol PQS Independent type-testing protocol WHO/PQS/FZO2-VP.2 Original: English Distribution: General TITLE: Water-pack freezer: absorption cycle Product verification protocol: E003/FZ02-VP.2 Applies to specification

More information

` PQS Independent type-testing protocol

` PQS Independent type-testing protocol ` PQS Independent type-testing protocol WHO/PQS/E003/FZ01-VP.2 Original: English Distribution: General TITLE: Vaccine freezer or combined vaccine and water-pack freezer: compression-cycle Product verification

More information

PQS performance specification

PQS performance specification PQS performance specification WHO/PQS/E003/RF02.2 Original: English Distribution: General TITLE: Refrigerator or combined refrigerator and water-pack freezer: absorption cycle Specification reference:

More information

PQS Independent type-testing protocol

PQS Independent type-testing protocol PQS Independent type-testing protocol WHO/PQS/E003/RF05-VP.2 Original: English Distribution: General TITLE: Refrigerator or combined refrigerator and water-pack freezer: compression-cycle. Solar direct

More information

PQS Quality Assurance protocol. TITLE: Cold Room/Freezer Room:

PQS Quality Assurance protocol. TITLE: Cold Room/Freezer Room: PQS Quality Assurance protocol WHO/XXX Original: English Distribution: General TITLE: Cold Room/Freezer Room: Note that this protocol is intended to form part of the contract documentation for a new cold

More information

CRITICAL CARE FOR CRITICAL NEEDS

CRITICAL CARE FOR CRITICAL NEEDS CRITICAL CARE FOR CRITICAL NEEDS Godrej Medical Refrigerators with Sure Chill technology ensure perfect temperature control with no risk of freezing. Sure Chill is a patented technology licensed by The

More information

After-sales Service Manual for WGG Solar Driven Vaccine Refrigerator

After-sales Service Manual for WGG Solar Driven Vaccine Refrigerator Security classification: As internal training material of Haier s service provider, it s prohibited to be distributed. After-sales Service Manual for WGG Solar Driven Vaccine Refrigerator Model: HTC-60

More information

TCW 2000 Ice liner refrigerator and freezer PIJ

TCW 2000 Ice liner refrigerator and freezer PIJ TCW 2000 Ice liner refrigerator and freezer OVER VIEW The unique rotomoulded Chest Freezer and inclined Refrigerator with two separate compartments and compressors worldwide Hold over time @ 32 C Hold

More information

PQS Independent type-testing protocol

PQS Independent type-testing protocol PQS Independent type-testing protocol WHO/PQS/RFO2-VP.2 Original: English Distribution: General TITLE: Refrigerator or combined refrigerator and water-pack freezer: absorption cycle Product verification

More information

creative thinking : powerful solutions The new True Energy Vaccine Refrigerator with Sure Chill technology

creative thinking : powerful solutions The new True Energy Vaccine Refrigerator with Sure Chill technology creative thinking : powerful solutions The new True Energy Vaccine Refrigerator with Sure Chill technology BLF 100 DC Sure Chill Vaccine Refrigerator PQS Code: E003/019 Description: Solar Direct Drive

More information

PQS performance specification

PQS performance specification PQS performance specification WHO/PQS/E006/TH06.2 Original: English Distribution: General TITLE: Integrated electronic thermometer, with or without alarm function, for vaccine refrigerators and freezers

More information

PQS Independent type-testing protocol

PQS Independent type-testing protocol PQS Independent type-testing protocol WHO/XXX Original: English Distribution: General TITLE: Integrated electronic maximum-minimum thermometer, with factory programmed alarms, for vaccine refrigerators

More information

INSTRUCTION MANUAL Portable Refrigerator Units MODEL 15-LITER Including the Standard Battery Backup System (BBS)

INSTRUCTION MANUAL Portable Refrigerator Units MODEL 15-LITER Including the Standard Battery Backup System (BBS) 1 INSTRUCTION MANUAL Portable Refrigerator Units MODEL 15-LITER Including the Standard Battery Backup System (BBS) SECTION TITLE PAGES 1 Introduction and Basic Operation 2-3 2 Cleaning & Storing 4 3 Basic

More information

PQS performance specification

PQS performance specification PQS performance specification WHO/PQS/E01/CR-FR01.1 Original: English Distribution: General TITLE: Cold rooms and freezer rooms Specification reference: E01/CR-FR01.1 Product verification protocol: E01/CR-FR01-VP1.1

More information

ENERGY EFFICIENCY STANDARD AND LABELING FOR REFRIGERATOR IN INDONESIA

ENERGY EFFICIENCY STANDARD AND LABELING FOR REFRIGERATOR IN INDONESIA Technical Reference on Harmonization of Energy Efficiency Test Methods of Refrigerators Toward the New IEC 62552 among APEC Region Held by China Standard Certification Guiyang China, 2 December 2015 Totok

More information

38-SDMS-03 SPECIFICATIONS FOR LV DIGITAL PANEL METERS

38-SDMS-03 SPECIFICATIONS FOR LV DIGITAL PANEL METERS SPECIFICATIONS FOR LV DIGITAL PANEL METERS This specification is property of SEC and subject to change or modification without any notice CONTENTS Clause Page 1.0 SCOPE 3 2.0 CROSS REFERENCES 3 3.0 APPLICABLE

More information

49 Danfoss Thermostat Kits Ranco Varifix Kits

49 Danfoss Thermostat Kits Ranco Varifix Kits Danfoss Thermostat Kits Code Type To Suit E005 NO-1 Kit Refrigerator E006 NO-2 Refrigerator Push/Defrost E007 NO-3 Fridge Freezer/Larder Fridge E008 NO-4 Absorption Refrigerator E009 NO-5 Freezer E010

More information

AG2TEMP PRESTIGE SPECIAL REFRIGERATOR Model: AG2TEMP SPECIAL

AG2TEMP PRESTIGE SPECIAL REFRIGERATOR Model: AG2TEMP SPECIAL AG2TEMP PRESTIGE SPECIAL REFRIGERATOR Model: AG2TEMP SPECIAL Arrowsmith and Grant Refrigeration Manufacturers & suppliers of prestige home refrigeration equipment. ABN: 64 007 296 586 28-30 Marni St Dandenong

More information

FSW SECTION. Product guide. Thermostats, Pressure Switches & Fan Speed Controls. E SECTION For more information visit

FSW SECTION. Product guide. Thermostats, Pressure Switches & Fan Speed Controls. E SECTION For more information visit FSW Product guide E SECTION Thermostats, Pressure Switches & Fan Speed Controls. 63 64 Head Office 01543 437 010 Danfoss Service Thermostat Kits TYPE TO SUIT E005 NO-1 Refrigerator E006 NO-2 Refrigerator

More information

Upright freezer V 60Hz ccl 4. Block condenser Aspera compressor grp. 38. Upright freezer compr. grp 38. Version: Date: Initials: Description:

Upright freezer V 60Hz ccl 4. Block condenser Aspera compressor grp. 38. Upright freezer compr. grp 38. Version: Date: Initials: Description: Upright freezer compr. grp 38 Version: Date: Initials: Description: Upright freezer 110-120V 60Hz ccl 4 Block condenser Aspera compressor grp. 38 Prepared: This material is protected by copyright and may

More information

Turbo Freeze function

Turbo Freeze function Turbo Freeze function Siena Chest Freezer Range 2011 Whirlpool EMEA Service Competence Center Office +49-(0)711-81071-3551 Mobile +49-(0)172-7505946 Stefan Bässler Service Engineer FSS & Food Preparation

More information

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A Blast Chiller / Freezer Instruction Manual Model DN492-A DN494-A 1 Safety Tips Position on a flat, stable surface. A service agent/qualified technician should carry out installation and any repairs if

More information

Laboratory Refrigerator/Deep Freezer TC 802

Laboratory Refrigerator/Deep Freezer TC 802 External Dimension: B = 600 mm D = 615 mm H = 2000 mm Inside Dimension: Useful space on top Useful space at the bottom B = 440 mm B = 431 mm D = 435 mm D = 435 mm H = 1105 mm H = 597 mm Capacity: 254 l

More information

PQS performance specification

PQS performance specification PQS performance specification WHO/PQS/E06/TR04.1 Original: English Distribution: General TITLE: Wall-mounted pen recording thermometer Specification reference: E06/TR04.1 Product verification protocol:

More information

38-SDMS-01 SPECIFICATIONS FOR FAULT INDICATORS FOR UNDERGROUND DISTRIBUTION NETWORKS

38-SDMS-01 SPECIFICATIONS FOR FAULT INDICATORS FOR UNDERGROUND DISTRIBUTION NETWORKS SPECIFICATIONS FOR FAULT INDICATORS FOR UNDERGROUND DISTRIBUTION NETWORKS This specification is property of SEC and subject to change or modification without any notice CONTENTS Clause Page 1.0 SCOPE 3

More information

OPTIONAL SPRING MTG HANGING CENTRES WATER CONN'S: TWO BSP MALE. 19 mm (3/4") ELECTRICAL CONDUIT HOLES ACCESS PANEL OUT (WATER) IN 485 MOUNTING

OPTIONAL SPRING MTG HANGING CENTRES WATER CONN'S: TWO BSP MALE. 19 mm (3/4) ELECTRICAL CONDUIT HOLES ACCESS PANEL OUT (WATER) IN 485 MOUNTING HWP 117 225 Ducted Water Cooled R410A Packaged Air Conditioner Dimensions (mm) Fig. 1 HWP 117 60 1210 SPRING MOUNTING CENTRES 690 (HEIGHT = 370) FILTER BOX PROJECTION Net Weight 105 kg Installation & Maintenance

More information

Internet. Climate rating definitions. Customer service.

Internet. Climate rating definitions. Customer service. Climate rating definitions Climate rating SN = Ambient temperatures of +10 C to + 32 C Climate rating N = Ambient temperatures of +16 C to + 32 C Climate rating ST = Ambient temperatures of +16 C to +

More information

No previous protocol.

No previous protocol. PQS Quality Assurance protocol WHO/PQS/E06/TR03.VP2.1 Original: English Distribution: General TITLE: Programmable electronic temperature and event logger systems with integral alarm and auto-dialler options

More information

Service Manual. Solar Direct Drive Vaccine refrigerator. Haier Medical and Laboratory Products Co,.Ltd. Model:HTC-60H & HTCD-160.

Service Manual. Solar Direct Drive Vaccine refrigerator. Haier Medical and Laboratory Products Co,.Ltd. Model:HTC-60H & HTCD-160. No.: HMRSM03-011 Service Manual Solar Direct Drive Vaccine refrigerator Model:HTC-60H & HTCD-160 Pictures: HTC-60H HTCD-160 Haier Medical and Laboratory Products Co,.Ltd Contents 1. Model definition...

More information

Chest Freezer Instruction manual

Chest Freezer Instruction manual Chest Freezer Instruction manual Model CE210-A / CE211-A / CE212-A Telephone Helpline: 1300 225 960 Safety Tips Position on a flat, stable surface. A service agent/qualified technician should carry out

More information

Summarizing the Needs, Feasibility, and Challenges

Summarizing the Needs, Feasibility, and Challenges Vietnam National EPI Solar Direct-Drive Refrigerators in Vietnam Summarizing the Needs, Feasibility, and Challenges Dr. Nguyen Van Cuong, Vietnam National EPI 2 Vietnam National EPI Contents Vietnam and

More information

PUR/HADF/ Due date : As per attach list of suppliers

PUR/HADF/ Due date : As per attach list of suppliers PUR/HADF/3489 9.10.2014 Due date :21-10-2014 As per attach list of suppliers Subject :Enquiry for Hamara Apana Deep freezer and pushcart Dear Sir You are aware of our existing scheme Hamara Apana Deep

More information

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV Amendment Sheet Code : M5ACV-2005-0002 Date : 08-05-2006 Superceded : M5ACV-2005-0001 Nomenclature Production spec variation Type of ref. connection X : Not applicable Electrical A : 220-240V/1Ph/50Hz

More information

FRIDGES AND FREEZERS COMBINED. EFC-2033 NF EX p. 108 EFC-2032 NF EX p. 109 EFC-2032 NF WH p. 109

FRIDGES AND FREEZERS COMBINED. EFC-2033 NF EX p. 108 EFC-2032 NF EX p. 109 EFC-2032 NF WH p. 109 COMBINED EFC-2033 NF EX p. 108 EFC-2032 NF EX p. 109 EFC-2032 NF WH p. 109 BUILT IN COMBINED TWO DOORS EFC-1711-I p. 112 EFT-1712 EX p. 113 EFT-1712 WH p. 113 DOOR ON DOOR EFS-1822 NF EX p. 116 EZS-1822

More information

S D HWP 77, 96. Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance. Fig. 1 Nomenclature. Fig.

S D HWP 77, 96. Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance. Fig. 1 Nomenclature. Fig. HWP 77, 96 Ducted Water Cooled R410A Packaged Air Conditioner Installation & Maintenance Fig. 1 Nomenclature Nomenclature e.g. H W P 7 7 C K Series Size Type S D GENERAL HWP - A general designation which

More information

BUSINESS SOLUTIONS. Biomedical REFRIGERATORS & FREEZERS FOR BIOMEDICAL NEEDS

BUSINESS SOLUTIONS. Biomedical REFRIGERATORS & FREEZERS FOR BIOMEDICAL NEEDS BUSINESS SOLUTIONS Biomedical REFRIGERATORS & FREEZERS FOR BIOMEDICAL NEEDS SOLUTIONS FOR DEMANDING NEEDS RELIABLE. USER-FRIENDLY. ECO-FRIENDLY Medical Certifications are key to success Our Premium line

More information

installation & operating instructions

installation & operating instructions installation & operating instructions RGE 410 RA/RM-2D 822706106 MO-M 0740 INTRODUCTION We are pleased that you have chosen this refrigerator and hope you will derive much satisfaction from using it.

More information

MANUAL. Instructions for installation use & general maintenance of your HORIZONTAL FREEZER HFF, FLORENCIA and MILAN Product Lines MAN-017-R

MANUAL. Instructions for installation use & general maintenance of your HORIZONTAL FREEZER HFF, FLORENCIA and MILAN Product Lines MAN-017-R MANUAL Instructions for installation use & general maintenance of your HORIZONTAL FREEZER HFF, FLORENCIA and MILAN Product Lines MAN-017-R LAST REVISION JULY 2009 INDEX Handling... 3 Installation... 4

More information

AS/NZS :2009. Performance of household electrical appliances Refrigerating appliances AS/NZS :2009

AS/NZS :2009. Performance of household electrical appliances Refrigerating appliances AS/NZS :2009 AS/NZS 4474.2:2009 (Incorporating Amendment Nos 1 and 2) Australian/New Zealand Standard Performance of household electrical appliances Refrigerating appliances Part 2: Energy labelling and minimum energy

More information

PR / MP I Laboratory / Medicine

PR / MP I Laboratory / Medicine Technology for Life Medical SYSTEMS Technology for Life PR / MP I Laboratory / Medicine / Pharmaceutical Refrigerators (with glass door) +5 C +4 C 292.9707.80 02/2013 BIOMEDICAL REFRIGERATION Innovative

More information

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING MODEL Premier Series 3000 USER MANUAL Non-Programmable Single Stage Heat/Cool Digital Thermostat Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single

More information

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER Instruction Manual Please read these instructions carefully before use and retain for future reference. Before switching on your

More information

S Y D. HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance

S Y D. HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner. Installation & Maintenance HWP 35, 47, 58 (c/w EC Motor & UC7 Controller) Ducted Water Cooled R410A Packaged Air Conditioner Installation & Maintenance Fig. 1 Nomenclature Nomenclature e.g. H W P 3 5 C K Series Size Type S Y D GENERAL

More information

AIR CONDITIONERS MINIMUM ENERGY PERFORMANCE, LABELLING AND TESTING REQUIREMENTS FOR LOW CAPACITY WINDOW TYPE AND SINGLE-SPLIT

AIR CONDITIONERS MINIMUM ENERGY PERFORMANCE, LABELLING AND TESTING REQUIREMENTS FOR LOW CAPACITY WINDOW TYPE AND SINGLE-SPLIT SAUDI ARABIAN STANDARD SASO 2663/2017 والجودة الھيئة السعودية للمواصفات والمقاييس Saudi Standards, Metrology and Quality Org (SASO) SASO 2663:2017 (Draft) AIR CONDITIONERS MINIMUM ENERGY PERFORMANCE, LABELLING

More information

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort Application guide FLATAIR - FLCK/FLHK Providing indoor climate comfort MSL60E-0701 12-2006 Congratulations you have made a wise choice and we feel sure that it will meet your expectation INDEX CONTENTS

More information

Vaccine Storage and Handling Studies at NIST

Vaccine Storage and Handling Studies at NIST Vaccine Storage and Handling Studies at NIST Michal Chojnacky National Institute of Standards and Technology Sensor Science Division, Themodynamic Metrology Group Gaithersburg, MD michalc@nist.gov http://www.nist.gov/pml/div685/grp01/vaccines.cfm

More information

VWR LABORATORY REFRIGERATORS AND FREEZERS. Versatile Storage Options Designed for Your Needs

VWR LABORATORY REFRIGERATORS AND FREEZERS. Versatile Storage Options Designed for Your Needs VWR LABORATORY REFRIGERATORS AND FREEZERS Versatile Storage Options Designed for Your Needs Going Green. What does it mean? The Advantages of Hydrocarbon Refrigerants 45-60% DECREASE IN REFRIGERANT CHARGE

More information

Majis Industrial Services SAOC TENDER NO. MISCP/09/2014

Majis Industrial Services SAOC TENDER NO. MISCP/09/2014 Majis Industrial Services SAOC TENDER NO. MISCP/09/2014 Expression of Interest for Performance-based Operation and Maintenance (O&M) Services for the 20 MLD Majis Seawater Desalination Plant in Sohar,

More information

ATD-3698 Refrigerant Gas Leak Detector. Owner s Manual

ATD-3698 Refrigerant Gas Leak Detector. Owner s Manual ATD-3698 Refrigerant Gas Leak Detector Detects all CFC, HFC, HCFC Refrigerants including blends Owner s Manual Design Certified to meet SAE J2791 for R134a WARNING: This product contains chemicals, including

More information

Bar Fridge USER MANUAL MB46W

Bar Fridge USER MANUAL MB46W Bar Fridge USER MANUAL MB46W CONTENTS Safety information... 2-3 Identifying parts of the fridge... 4 Transporting... 5 Installation... 5 Reversing the door... 6 Operating instructions... 7 Cleaning &

More information

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference 3000 Premier Series Non-Programmable Single Stage /Cool Digital Thermostat OWNERS MANUAL Compatible with low voltage single stage gas, oil or electric heating or cooling systems, including single stage

More information

Refrigerating Appliance ErP Test Report

Refrigerating Appliance ErP Test Report Report Number Test Laboratory Name / Address Applicant Name / Address Manufacturing Name / Address Product Brand Name Description Model(s) (if applicable) Model Similarity Ratings Date of receipt of sample(s)

More information

DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL

DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL Service Information If service or parts are required, contact the nearest Norcold Service Center. To find

More information

HOBO U14 Data Logger User Manual

HOBO U14 Data Logger User Manual HOBO U14 Data Logger User Manual The U family of data loggers offers reliability and convenient monitoring for applications that require higher accuracy, better resolution, more memory, or USB connectivity

More information

SERVICE MANUAL REFRIGERATION

SERVICE MANUAL REFRIGERATION SERVICE MANUAL REFRIGERATION ELECTROLUX HOME PRODUCTS S.p.A. Publication no. Spares Operations Italy 599 37 75-07 Corso Lino Zanussi, 30 060824 I - 33080 PORCIA / PN (ITALY) ITZ/SERVICE/AA Fax +39 0434

More information

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A Blast Chiller / Freezer Instruction Manual Model DN492-A DN494-A Safety Tips Position on a flat, stable surface. A service agent/qualified technician should carry out installation and any repairs if required.

More information

SERVICE MANUAL MULTI DECK 60 HOT MERCHANDISER MULTI DECK 100 HOT MERCHANDISER MULTI DECK 120 HOT MERCHANDISER CLASSIC DECK HOT MERCHANDISER

SERVICE MANUAL MULTI DECK 60 HOT MERCHANDISER MULTI DECK 100 HOT MERCHANDISER MULTI DECK 120 HOT MERCHANDISER CLASSIC DECK HOT MERCHANDISER SERVICE MANUAL MULTI DECK 60 HOT MERCHANDISER MULTI DECK 100 HOT MERCHANDISER MULTI DECK 120 HOT MERCHANDISER CLASSIC DECK HOT MERCHANDISER Classic Deck Hot Multi Deck 60 Multi Deck 100 Multi Deck 120

More information

USER GUIDE. TL6015W TL6018W 60cm Larder

USER GUIDE. TL6015W TL6018W 60cm Larder USER GUIDE TL6015W TL6018W 60cm Larder Thank you for buying this high quality appliance This handbook is designed to help you through each step of owning your new appliance, from installation to use. Please

More information

DC COMPRESSOR FRIDGE-FREEZER Grape Glacier 2.75 INSTRUCTION MANUAL ENGLISH

DC COMPRESSOR FRIDGE-FREEZER Grape Glacier 2.75 INSTRUCTION MANUAL ENGLISH DC COMPRESSOR FRIDGE-FREEZER Grape Glacier 2.75 INSTRUCTION MANUAL ENGLISH Congratulations on the purchase of this quality Refrigerator-Freezer. We the manufacturer trust that you will enjoy many years

More information

Reliable cooling solutions...

Reliable cooling solutions... Over 1,50,000 satisfactory installations in India Reliable cooling solutions......for demanding needs Life saving vaccinations must be stored under exacting conditions to ensure maximum efficacy. Celfrost

More information

USER MANUAL. Platinum Refrigerator & Freezer Range

USER MANUAL. Platinum Refrigerator & Freezer Range USER MANUAL Platinum Refrigerator & Freezer Range 1 Contents Positioning of the product 3 Transportation and moving the product 3 Energy saving tips 4 Important information 4 Product information 4 Product

More information

PSJR /PSSR Models. NOTE: The document is to be used in conjunction with the Dinex s Perfect Serv Operation Manual

PSJR /PSSR Models. NOTE: The document is to be used in conjunction with the Dinex s Perfect Serv Operation Manual Perfect Serv PSJR /PSSR Models Introduction............................................................................ Installation & Operating Instructions......................................................

More information

Eligibility Criteria for Participation [Qualification Requirement (QR)]

Eligibility Criteria for Participation [Qualification Requirement (QR)] Eligibility Criteria for Participation [Qualification Requirement (QR)] 1. Only Manufacturers are eligible to Quote: a) Original manufacturers of High Voltage Detector in India will be eligible in the

More information

PQS performance specification

PQS performance specification PQS performance specification WHO/PQS/E06/TR03.1 Original: English Distribution: General TITLE: Programmable electronic temperature and event logger systems with integral alarm and auto-dialler options

More information

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table) 1 2 Warning: - Do not place your hand or any other objects into the air outlet and fan. It could damage the heat pump and cause injuries; - In case of any abnormality with the heat pump, cut off the power

More information

RE-PR3-E-27 3-Phase Panel Mount 27kW

RE-PR3-E-27 3-Phase Panel Mount 27kW Page 1 of 6 RE-PR3-E-27 3-Phase Panel Mount 27kW Features: Benefits: 0-10Vdc, 0-5Vdc, 4-20mA or manual via potentiometer control input Over temperature protection with auto reset Enclosed panel mounting

More information

Guided Learning Hours (GLH) 8 Invigilated Assessment Hours (IA) 2 Total Qualification Time (TQT) 10

Guided Learning Hours (GLH) 8 Invigilated Assessment Hours (IA) 2 Total Qualification Time (TQT) 10 Qualification: Date Completed: 02 Feb 17 Unit: FIA AO Level 3 Fire Detection and Alarm Advanced Installer Development Group: FD&A Development Group Guided Learning Hours (GLH) 8 Invigilated Assessment

More information

TFFR01 MANUAL PORTABAL 12/24 VOLTS DC REFRIGERATOR / FREEZER.

TFFR01 MANUAL PORTABAL 12/24 VOLTS DC REFRIGERATOR / FREEZER. TFFR01 MANUAL PORTABAL 12/24 VOLTS DC REFRIGERATOR / FREEZER www.terrafirma4x4.com 1 Safety Awareness Read this manual carefully and understand the contents before you install the refrigerator / freezer.

More information

WARNING Important Safety Information

WARNING Important Safety Information Builder Series Non-Programmable Thermostat MODEL 00NC Heat Only or Cool Only Thermostat Before Installing, Programming or Operating, PLEASE READ ALL INSTRUCTIONS Specifications Temperature Adjustment WARNING

More information

USER MANUAL. Pharmacy Refrigerator Range. Applicable models: PSR353/PGR353 PSR273/PGR273 PSR151/PGR151

USER MANUAL. Pharmacy Refrigerator Range. Applicable models: PSR353/PGR353 PSR273/PGR273 PSR151/PGR151 USER MANUAL Pharmacy Refrigerator Range Applicable models: PSR353/PGR353 PSR273/PGR273 PSR151/PGR151 1 Contents Before first use 3 Positioning of refrigerator 3 Transportation and moving of refrigerator

More information

IQ/OQ Protocol Installation Qualification/ Operation Qualification zz FreeZone Stoppering Tray Dryer & Bulk Tray Dryer Freeze Dry Systems

IQ/OQ Protocol Installation Qualification/ Operation Qualification zz FreeZone Stoppering Tray Dryer & Bulk Tray Dryer Freeze Dry Systems IQ/OQ Protocol Installation Qualification/ Operation Qualification zz FreeZone Tray Dryer & Bulk Freeze Dry Systems Labconco o: 1059501 Rev. - Purpose and Scope IQ and OQ This Qualification Protocol is

More information

AGN81800C0. RRP AUS $3, L integrated freezer with SoftClose hinges & LCD touch controls. AGN81800C0-216L integrated freezer

AGN81800C0. RRP AUS $3, L integrated freezer with SoftClose hinges & LCD touch controls. AGN81800C0-216L integrated freezer AGN81800C0 RRP AUS $3,299.00 216L integrated freezer with SoftClose hinges & LCD touch controls Product Details Features SoftClose hinges LCD electronic touch controls Frostmatic function Automatic defrost

More information

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017 STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017 STANDARD INFORMATION Standard Number: UL 412 Standard Name: Refrigeration Unit Coolers Standard Edition and Issue Date: 5 th Edition Dated August 22,

More information

Portable Refrigerator

Portable Refrigerator Portable Refrigerator Owners Manual Single door 40 litre 65 litre 80 litre 125 litre Double door 74 litre 95 litre 2009 Introduction The National Luna range of portable fridges and freezers are high-performance,

More information

Ultra Deep Freezers -86 C. Biomedical Refrigeration I UF. Technology for life _8pages_dometic_UF.indd 1 10/09/08 11:17:32

Ultra Deep Freezers -86 C. Biomedical Refrigeration I UF. Technology for life _8pages_dometic_UF.indd 1 10/09/08 11:17:32 Ultra Deep Freezers Biomedical Refrigeration I UF -86 C Technology for life 504170_8pages_dometic_UF.indd 1 10/09/08 11:17:32 UF - Ultra Deep Freezers up to -86 C The models UF 455 G & UF 755 G reflect

More information

E01: Cold rooms and freezer rooms

E01: Cold rooms and freezer rooms DRAFT PQS E01 CR-FR-D3 WHO/V&B/02.33 IGINAL:ENGLISH Equipment performance specifications and test procedures E01: Cold rooms and freezer rooms VACCINES AND BIOLOGICALS WLD HEALTH GANIZATION This module

More information

Instruction manual Harmo PAC ZVWX1017/1022/1032/1041/1055/1056/1061

Instruction manual Harmo PAC ZVWX1017/1022/1032/1041/1055/1056/1061 Instruction manual Harmo PAC ZVWX1017/1022/1032/1041/1055/1056/1061 Imported by: Zwembad BVBA Industrieweg 9 3190 Boortmeerbeek België www.harmopool.eu 0 Table of content Introduction... 2 Safety instructions...

More information

MYSTICOOL Max Valve System with Xstream and A.R.M.E.D. Technology Service & Installation Instructions Page 1

MYSTICOOL Max Valve System with Xstream and A.R.M.E.D. Technology Service & Installation Instructions Page 1 Page 1 WHY should I install the MYSTICOOL Max Valve System? XDX is more efficient, saving on power consumption. Use of XDX system decreases defrost cycles. XDX maintains more consistent product temperatures,

More information

RDT Refrigeration Book

RDT Refrigeration Book RDT Refrigeration Book Indoor / Outdoor Air-Cooled Systems Indoor Air-Cooled Systems 1. Shorter line runs. 2. Systems located off roof or dock space. 3. Weather covers are not required (saves cost). 4.

More information

ER MANUAL FOR YOUR BAUMATIC

ER MANUAL FOR YOUR BAUMATIC BW18BL 50 litre thermoelectric beverage centre BW28BL 70 litre thermoelectric beverage centre ER MANUAL FOR YOUR BAUMATIC BW18BL 50 litre thermoelectric beverage centre BW28BL 70 litre thermoelectric beverage

More information

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13

TABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13 R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.

More information

XSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1

XSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1 Page 1 WHY should I install the XSTREAM Valve System? XDX is more efficient, saving on power consumption. Use of XDX system decreases defrost cycles. XDX maintains more consistent product temperatures,

More information

Installation Operation Maintenance

Installation Operation Maintenance Installation Operation Maintenance Series R Air-Cooled Helical Rotary Liquid Chiller RTAD 085-180 (50Hz) Standard, Free Cooling and Heat Recovery models RTAD-SVX01F-E4 General information Foreword These

More information

L. Terminal block Connecting Label:

L. Terminal block Connecting Label: TABLE OF CONTENT A. Installation and Mounting.. 3 1. Installation 3 2. Wiring... 4 3. Mounting.. 5 B. Key Interface. 7 C. LCD Interface...8 D. Start/Reset...9 E. Operation Mode.10 F. Time Setting Mode.11

More information

Installer Guide. WARNING Important Safety Information. 1 Specifications

Installer Guide. WARNING Important Safety Information. 1 Specifications 1 Specifications cont. Premier Series Universal Auto Changeover Up to 3 Heat / 2 Cool Heat Pump or 2 Heat / 2 Cool Conventional Thermostat Installer Guide Before Installing, Programming or Operating, PLEASE

More information

MOBILE COOLING BUYING GUIDE EVERYTHING YOU NEED TO KNOW

MOBILE COOLING BUYING GUIDE EVERYTHING YOU NEED TO KNOW GUIDE BUYING GUIDE EVERYTHING YOU NEED TO KNOW Mobile living made easy. DEAR FREEDOM LOVER, There are millions of people around the world who use Dometic products. You all have one thing in common. You

More information

The products covered by the Regulation can be classified as follows:

The products covered by the Regulation can be classified as follows: Table of Contents 1. Purpose of the guidelines and disclaimer... 3 1.1. The Regulation... 3 2. Scope... 3 3. Product environmental impacts... 4 4. State of play of legislation... 4 4.1. History of the

More information

Battery Powered Electronic Programmable Room Thermostat

Battery Powered Electronic Programmable Room Thermostat Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035 Operating & Installation Instructions What is a programmable room thermostat?...an explanation for householders A programmable room

More information

600 / 400 / 150 litre series Refrigerators/Freezers Instruction manual

600 / 400 / 150 litre series Refrigerators/Freezers Instruction manual 600 / 400 / 150 litre series Refrigerators/Freezers Instruction manual Models: CD080-A/CD081-A/CD082-A/CD083-A/CD084-A/CD085-A/CD610-A/CD611-A/ CD612-A/CD613-A/CD614-A/CD615-A/CD086-A/CD087-A/CD088-A Telephone

More information

Massachusetts COOL SMART

Massachusetts COOL SMART Massachusetts COOL SMART 2015 RESIDENTIAL DUCTLESS MINI-SPLIT HEAT PUMP Rebate Application Ductless Mini-Split Heat Pump REBATE COOL SMART is offering residential customers of program sponsors up to a

More information

FSTC Equipment Test Report

FSTC Equipment Test Report FSTC Equipment Test Report Purpose of Testing The Stirling Ultracold SU780XLE freezer was tested to characterize its energy usage and temperature stability during periods of both idle and door openings

More information

DEVIreg Opti Electronic Timer Thermostat fulfilling Eco Design Directive

DEVIreg Opti Electronic Timer Thermostat fulfilling Eco Design Directive DEVIreg Opti Electronic Timer Thermostat fulfilling Eco Design Directive www.devi.com Table of Contents 1. Introduction..................................... 2 2. Technical Specifications.........................

More information