ELECTRIC PASTA COOKERS

Size: px
Start display at page:

Download "ELECTRIC PASTA COOKERS"

Transcription

1 OPTIMUM 700 & 900 ELECTRIC PASTA COOKERS BUILDER S SPECIFICATIONS Part A: Technical characteristics Part B: Technical instructions for the installer - WARNING - Installation and repairs must be carried out by personnel approved by the manufacturer and in accordance with current regulations and standards. If any modifications are made the manufacturer can accept no responsibility whatsoever. These appliances must be used in a well-ventilated area. Read the notice carefully before installation. When handling it, it is imperative to leave the appliance on its base till final installation. 3BE390723NI

2 Page 1 3BE390723NI 11/09 TABLE OF CONTENTS ELECTRIC PASTA COOKERS A) TECHNICAL CHARACTERISTICS... 2 B) TECHNICAL INSTRUCTIONS FOR THE INSTALLER 1. FIRM PLATES PLATE LOCATION OF THE PLATE INSTALLATION: GENERALITIES GENERAL REQUIREMENTS HANDLING UNPACKING ACCESS TO THE COMPONENTS PLACED BEHIND THE FASCIA INSTALLATION: PUTTING IN PLACE ASSEMBLY OF CANTILEVER APPLIANCES TO A WALL ASSEMBLY OF APPLIANCES TO AN INDIVIDUAL BASE ASSEMBLY OF APPLIANCES ON A COMMON BASE ASSEMBLY OF APPLIANCES ON A MASONRY BASE INSTALLATION: CONNECTIONS ELECTRIC CONNECTION WATER CONNECTION DRAINAGE CONNECTION

3 Page 2 3BE390723NI 11/09 A: TECHNICAL CHARACTERISTICS OPTIMUM 700, Electric pasta cooker P ELECTRIC connection (Foresee a cable with 1.5 m free length) HOT WATER DRAINAGE MODEL B-B709.CP400 DIMENSIONS (mm) Width 400 Depth x Height 730 x 959 Basket 90 x 280 x 160 CAPACITIES (mm) Tank (litres) 20 Basket (kg) 0.5 PACKAGING (mm) Width 500 Depth x Height 830 x 1150 WEIGHT (KG) 70 ELECTRICITY (Three-phase 230V+T or 400V+N+T) Power (kw) 230V 3a.c V 3Na.c. 9 Max. intensity (A) 230V 3a.c V 3Na.c. 13 HOT WATER Pressure 2.5/6 bars Water hardness 70 ppm Max. temperature 60 C Connection Hose 20/27 (3/4 ) DRAINAGE Connection Diameter 28 SAFETY OPERATION Heating with no water TYPE OF APPLIANCE Back to the wall or another appliance ELECTRIC CONNECTION Electric outlet at 390 mm above the floor. This document is not contractual; Edition 11/2009 3BE0584FT

4 Page 3 3BE390723NI 11/09 OPTIMUM 900, Electric pasta cooker P ELECTRIC connection (Foresee a cable with 1.5 m free length) HOT WATER DRAINAGE MODEL B-B909.CP400 DIMENSIONS (mm) Width 400 Depth x Height 920 x 959 Basket 90 x 280 x 160 CAPACITIES (mm) Tank (litres) 20 Basket (kg) 0.5 PACKAGING (mm) Width 500 Depth x Height 1030 x 1150 WEIGHT (KG) 55 ELECTRICITY (Three-phase 230V+T or 400V+N+T) Power (kw) 230V 3a.c V 3Na.c. 9 Max. intensity (A) 230V 3a.c V 3Na.c. 13 HOT WATER Pressure 2.5/6 bars Water hardness 70ppm Max. temperature 60 C Connection Hose 20/27 (3/4 ) DRAINAGE Connection Diameter 28 SAFETY FUNCTIONING Heating without water TYPE OF APPLIANCE Back to the wall or another appliance ELECTRIC CONNECTION Electric outlet at 390 mm above the floor. This document is not contractual; Edition 11/2009 3BE0585FT

5 Page 4 3BE390723NI 11/09 1. FIRM PLATE 1.1 PLATE Firm plate In any correspondence about your equipment, please indicate: - The model number (Model.) - The serial number (Fab.Nr.) - The date (Date). 1.2 LOCATION OF THE FIRM PLATE The firm plates are fixed on the control board (see the diagrams hereafter). Location of the firm plate

6 Page 5 3BE390723NI 11/09 2. INSTALLATION: GENERALITIES NATURE AND POSITION OF THE CONNECTIONS See the "Technical characterisitcs" at the beginning of these instructions. 2.1 GENERAL REQUIREMENTS A qualified engineer must carry out the installation, modification or repair of the appliance in a workmanlike manner. These appliances must be installed with sufficient ventilation to prevent the formation of excessive concentrations of substances noxious for the health in the room in which they are installed. The equipment is not designed to work in an explosive atmosphere. Due to this, it must not be installed in a zone subject to ATEX directive. The appliances must be installed according to the standard EN 1717 and the national regulation in force relating to water. These units must only be placed against a wall or a partition. The latter must be of non-combustible materials or, if not, must be covered with an appropriate, good insulating and non-combustible material. The manufacturer certifies that the packaging meets the provision 94/62/CE (provision relating to packagings and packaging waste of ) and requests that final installer (and user) observes the rules relating to the removal of the packaging (recycling or reconditioning). 2.2 HANDLING The appliance should only be handled with adapted lifting equipment. Should the appliance need to be transported, this must be on its original pallet and it must not be stacked on other appliances under any circumstances. If the appliance is to be moved without its pallet, it should be carried and not pulled. 2.3 UNPACKING Before installation, remove the strapping from the appliance. The individual parts are not bolted down. Remove the protective plastic film from the stainless steel parts before heating.

7 2.4 ACCESS TO THE COMPONENTS PLACED THE FASCIA Page 6 3BE390723NI 11/09 - Unscrew both M5 x 16 screws under the fascia. - Tilt the fascia: Slightly pull downwards 1 then to yourself Put the fascia in locking position: clamp both lugs into the apertures foreseen in the fascia.

8 Page 7 3BE390723NI 11/09 3. INSTALLATION: PUTTING IN PLACE 3.1 ASSEMBLY OF CANTILEVER APPLIANCES TO A WALL Drilling pattern The fixation of a bracket must support a tensile strength of 400 dan (2 brackets for a 400, 800, 1000 or 1200 wide appliance). It is recommended, for the fixation of cantilever appliances to a concrete wall, to observe the following points: * The reinforced concrete of the wall must be at least of quality 23 MPA (DTU). * Use HSA-R M 8x75 plugs or equivalent (2 for cooking tops and 6 for cooking units). * For the plugs above, each hole must be drilled to diameter 8 mm and, at least, 65 mm deep. Procedure - Fix the lower bearing beam of the appliances against the wall. Warning! Check this bearing beam is properly horizontal. - Fix the template supplied by two 5 screws to the wall. Check horizontality

9 Page 8 3BE390723NI 11/09 - Drill through the 5 fixation holes of the brackets. Use the upper holes (2 brackets per appliance). Note: In case of impossibility (due to the presence of technical ducts, a metal strengthener in the wall ), drill through the lower holes in the template. - Remove the template. - Increase the bracket fixation holes to diameter 8 and, at least, to 65 mm in depth. - Fix the brackets to the wall. Use HSA-R M 8x75 plugs or equivalent. - Open the brackets to the maximum by means of the centre screw Opened bracket Fixation screw Opening screw - Put the appliances in place on the brackets and lock them. Warning! The appliances must rest on the bearing beam. Bracket Bearing beam

10 Page 9 3BE390723NI 11/09 - Fix the appliances between themselves from behind in the way of collectors by one HM5 X 16 screw + ø 5 flat washer. - Fix the appliances between themselves from the front after having removed the front fascia (see paragraph 3.4) with one HM5 X 16 screws + Ø 5 flat washers. 3.2 ASSEMBLY OF THE APPLIANCES ON AN INDIVIDUAL BASE - Fix the appliances between themselves at the back in the way of collectors by one HM5 X 16 screw + ø 5 flat washer. - Fix the appliances between themselves at the front after having removed the front fascia (see paragraph 3.4) with one HM5 X 16 screws + Ø 5 flat washers.

11 3.3 ASSEMBLY OF THE APPLIANCES ON A COMMON BASE Page 10 3BE390723NI 11/09 - Put an appliance on the base, the back parts of the appliance and the base being approximately in alignment. (The base is is symmetrical, the back and front parts being identical). - Push the appliance backwards until the hooks made in its bottom slots into the square holes size 25 x 25 foreseen for this purpose. Hook fixation (detail) Hook Hole - Perform these two operations for each appliance put on the same base. - From front, fix the appliance on the base with two HM 5 x 16 screws + 2 ø 5 flat washers from the underside. - Fix the appliances between themselves at the back in the way of collectors with one HM5 X 16 screw + Ø 5 flat washer. - Fix the appliances between themselves at the front after having removed the front fascia (see paragraph 3.4) with one HM5 X 16 screws + Ø 5 flat washers.

12 3.4 ASSEMBLY OF THE APPLIANCES ON A MASONRY BASE Dimension of the masonry base for wall or central stove Page 11 3BE390723NI 11/09 Wall (side view) Centrally (side view) Stove depth Stove depth Stove depth Am Ac Finished Full tiled base height with tiled front Full tiled base Full tiled base 1 cm/m maximum slope 1 cm/m maximum slope 1 cm/m maximum slope Finished height with tiled front (front view) Lf: Stove width Ls Full tiled base Range Am Base depth as a wall version Dimension of the base Ac Ls Base depth as a central Base length version Finished height, completely tiled on the front Optimum Lf Optimum Lf The technical compartment is compulsory if the switch-off tap, the shut-off valve, or the reducing valve are in the stove. There are two possibilities: 1) Neutral top on a 200 or 400 wide technical compartment. 2) Cupboard foreseen for taps and sized 400 with all possibilities of cooking or neutral tops except induction.

13 Assembly of the appliances on a masonry base Page 12 3BE390723NI 11/09 Possibility to lay piping on the front Appliance Base space 2000 Trimming plinth Ventilation Base height at front Put the appliances in place on the masonry base. Note: If the appliances are delivered separately from the base, install the appliances on one or more bases space Connect electrical supply to the appliances (see paragraph 5: Installation: Connections) Assemble the appliances between themselves. - Fix the appliances between themselves at the back in the way of collectors with one HM5 X 16 screw + Ø 5 flat washer. - Fix the appliances between themselves at the front having removed the fascia (see paragraph 2.2.3) with two HM5 X 16 screws + Ø 5 flat washers. Connect gas, water and drainage lines to the appliances. Fit the trimming plinths. One front plinth per space 2000 base and one right and left end trimming plinth per stove, depending on order. - Assemble one or more front plinths with junctions (depending on the quantity of bases) (2 screws per plinth). - Fix one or more front plinths 1 and 2) onto one or more bases (two screws at least per plinth). - Fix the back part (on the end appliances before their final installation) on the base with the hex head screw (3). - Fix the right and left end trimming kits (4) (2 front screws and 1 back screw)

14 4.1 ELECTRIC CONNECTION Page 13 3BE390723NI 11/09 4. INSTALLATION: CONNECTIONS Location of the equipotentiality terminal Electric connection is carried out from behind of the appliance, whatever the model. - Loosen the fixation screw and remove the cover of the connecting box. - Introduce the cable through the gland. - Tighten the gland. - Connect the wires. - Put the cover back in place and fix it. - Connect the equipotential link to the terminal foreseen for the purpose. Only use supply cables of the H07 RN-F type with section : Voltages Sections 230 V 3 a.c. 4 x 4 mm V 3N a.c. 5 x 2.5 mm 2 Foresee an omnipolar shut off device patented for safety of personnel (with a distance between contacts of at least 3 mm when opened). The installation must meet the national rules in force (France: NFC ). The appliance must be connected to the earth. The different electric appliances must also be connected by means of an equipotential line (all metallic structures to the same voltage) by means of a terminal provided for this purpose and located beside the connecting gland. The builder denies all responsibility in the case where the instructions above are not observed.

15 Page 14 3BE390723NI 11/ WATER CONNECTION - Hot water. - Minimum pressure 2.5 bars, maximum 6 bars. - Maximum temperature for hot water 60 C. - Connection of flexible hose of diameter 15/21 (1/2"). - Foresee a shut off valve in the vicinity. 4.3 DRAINAGE CONNECTION Drained water is at a temperature of 100 C, due to this exclude the PVC-type materials. Foresee piping depending on the reservation 50 mm minimum IMPORTANT: In the framework of protection against pollution of mains water, IT IS STRICTLY PROHIBITED TO CONNECT THE APPLIANCE DIRECTLY TO THE OUTER SEWAGE SYSTEM (in a tight manner). So as to avoid any rise of sewage water into the enclosure of the recipient, a vent to open air must be foreseen between the drainage system of the appliance and the outer sewage line. The drain must include a siphon to fight against any return of bad smells. Recommended solution: 50 mm Ø100 siphon type plug (under the slab) or gutter

OPTIMUM 700 PASTA COOKER ELECTRIC BUILDER S SPECIFICATIONS. Part A: Technical characteristics Part B: Technical instructions for the installer

OPTIMUM 700 PASTA COOKER ELECTRIC BUILDER S SPECIFICATIONS. Part A: Technical characteristics Part B: Technical instructions for the installer OPTIMUM 700 PASTA COOKER ELECTRIC BUILDER S SPECIFICATIONS Part A: Technical characteristics Part B: Technical instructions for the installer WARNING Installation and repairs must be carried out by personnel

More information

GAS & ELECTRIC BOILING PANS

GAS & ELECTRIC BOILING PANS OPTIMUM 700 & 900 GAS & ELECTRIC BOILING PANS BUILDER S SPECIFICATIONS Part A: Technical characteristics Part B: Technical instructions for the installer WARNING Installation and repairs must be carried

More information

GAS & ELECTRIC FRYERS

GAS & ELECTRIC FRYERS OPTIMUM 700 & 900 GAS & ELECTRIC FRYERS BUILDER S SPECIFICATIONS Part A: Technical characteristics Part B: Technical instructions for the installer - WARNING - Installation and repairs must be carried

More information

GAS & ELECTRIC BRATT PANS

GAS & ELECTRIC BRATT PANS OPTIMUM 700 & 900 GAS & ELECTRIC BRATT PANS BUILDER S SPECIFICATIONS Part A: Technical characteristics Part B: Technical instructions for the installer WARNING Installation and repairs must be carried

More information

GAS & ELECTRIC BRATT PANS

GAS & ELECTRIC BRATT PANS OPTIMUM 700 & 900 GAS & ELECTRIC BRATT PANS BUILDER S SPECIFICATIONS Part A: Technical characteristics Part B: Technical instructions for the installer WARNING Installation and repairs must be carried

More information

BOILING PANS GAS & ELECTRICS

BOILING PANS GAS & ELECTRICS PREMIUM BOILING PANS GAS & ELECTRICS MANUFACTURER'S INSTRUCTIONS Part A: Technical data Part B: Installation manual - WARNING - Installation and repairs must be carried out by personnel approved by the

More information

GAS FR25 IR FRYERS. Grande Carte SPECIFICATIONS CONSTRUCTEUR. Part A: Technical characteristics Part B: Technical instructions for installation

GAS FR25 IR FRYERS. Grande Carte SPECIFICATIONS CONSTRUCTEUR. Part A: Technical characteristics Part B: Technical instructions for installation Grande Carte GAS FR25 IR FRYERS SPECIFICATIONS CONSTRUCTEUR Part A: Technical characteristics Part B: Technical instructions for installation - WARNING - Installation and repairs must be carried out by

More information

GAS FRYERS GRANDE CARTE MANUFACTURER S INSTRUCTIONS. Part A: Technical characteristics Part B: Installation instructions.

GAS FRYERS GRANDE CARTE MANUFACTURER S INSTRUCTIONS. Part A: Technical characteristics Part B: Installation instructions. GRANDE CARTE GAS FRYERS MANUFACTURER S INSTRUCTIONS Part A: Technical characteristics Part B: Installation instructions - WARNING - Installation and repairs must be carried out by personnel approved by

More information

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI200EN 09/2017

More information

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI100EN 09/2017

More information

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI500EN 09/2017

More information

Rif Cod i220-0

Rif Cod i220-0 15 52 50 6 13 53 51 2 9 8 3 20 19 18 5 1 7 14 10 4 17 Rif Cod 1 0010060 2 0060287 3 0060310 4 0080003 5 0080004 6 0080051 7 0080053 8 0080410 9 0080413 10 0080430 11 0080432 12 0080434 13 0080435 14 0080436

More information

INDEX RECOMMENDATIONS AND SUGGESTIONS... 4 CHARACTERISTICS... 5 INSTALLATION... 6 USE... 9 MAINTENANCE... 11

INDEX RECOMMENDATIONS AND SUGGESTIONS... 4 CHARACTERISTICS... 5 INSTALLATION... 6 USE... 9 MAINTENANCE... 11 INDEX EN RECOMMENDATIONS AND SUGGESTIONS... 4 CHARACTERISTICS... 5 INSTALLATION... 6 USE... 9 MAINTENANCE... 11 2 RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this

More information

Moisture inside the drum is due to final testing. Mains cable. Water outlet

Moisture inside the drum is due to final testing. Mains cable. Water outlet Safety instructions Moisture inside the drum is due to final testing. Scope of delivery depending on model The washing machine is heavy - take care when lifting. Caution: frozen hoses can crack/burst.

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC AQB09JJ6WC_IM_E_2585 2006.4.17 4:26 PM Page 17 INSTALLATION MANUAL Indoor Unit AQB09JJWC AQB12JJWC Outdoor Unit UQB09JJWC UQB12JJWC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

700XP & 900XP accessories

700XP & 900XP accessories 700XP & accessories electrolux 700XP & accessories 3 Index specific functions...3 gas ranges...4 electric ranges...6 induction ranges...7 oven ranges...8 fry tops...9 grills... 11 multifunctional cookers...14

More information

ACCESSORIES EVO700 EVO900

ACCESSORIES EVO700 EVO900 ACCESSORIES EVO700 INDEX ACCESSORIES FOR SPECIFIC FUNCTIONS... 4 Accessories for gas ranges... 4 Accessories for gas boiling top... 6 Accessories for electric ranges... 6 Accessories for induction ranges...

More information

AUTOMATIC GRANULAR ICE FLAKER

AUTOMATIC GRANULAR ICE FLAKER AUTOMATIC GRANULAR ICE FLAKER INSTRUCTIONS AND WARNINGS 24480 rev. 01 It is strictly forbidden to reproduce this instruction manual or any part thereof. Dear Customer, Congratulations on choosing a

More information

700XP & 900XP accessories

700XP & 900XP accessories 700XP & accessories electrolux 700XP & accessories 3 Index specific functions...4 gas ranges...4 gas boiling top HP...6 electric ranges...6 induction ranges...7 oven ranges...8 fry tops...9 grills...

More information

Moisture inside the drum is due to final testing.

Moisture inside the drum is due to final testing. Safety instructions Scope of delivery depending on model Moisture inside the drum is due to final testing. Removing the transport safety devices Water connection depending on model The washing machine

More information

Technical data. Bathroom/shower room installations. Water services (WRAS approved)

Technical data. Bathroom/shower room installations. Water services (WRAS approved) Technical data The Closomat toilet MUST be installed by a competent or qualified person. Explanation of symbols Safety instructions in this manual are identified by symbols. The safety instructions are

More information

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC AQB8J6WC_IM_E_25864 2006.4.4 3:29 PM Page 7 INSTALLATION MANUAL Indoor Unit AQB8J6WC AQB24J2WC Outdoor Unit UQB8J6WC UQB24J2WC ENGLISH FRANÇAIS ESPAÑOL Split-type Air Conditioner (Cooling and Heating)

More information

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance Installation Operation Commissioning Maintenance HOT AIR GENERATOR WITH GAS BURNER GGS NA11.45 A 06-2011 04-2011 CONTENTS 1. DESCRIPTION OF THE UNIT 2. INSTALLATION & CONNECTION 3. COMMISSIONING 4. CARE

More information

CANOPY RANGEHOOD OFFBOARD INSTALLATION INSTRUCTIONS

CANOPY RANGEHOOD OFFBOARD INSTALLATION INSTRUCTIONS Congratulations on your purchase! Thank you for choosing a Sirius product. CANOPY RANGEHOOD OFFBOARD INSTALLATION INSTRUCTIONS SLTC EM 107 G900 EAN# 9351116001766 SLEM 107 S900 EAN# 9351116001759 SLEM

More information

LEIHDC70SC - LEIHDC70BB LEIHDC70BC. Instructions Manual.

LEIHDC70SC - LEIHDC70BB LEIHDC70BC. Instructions Manual. LEIHDC70SC - LEIHDC70BB LEIHDC70BC Instructions Manual www.rangemaster.co.uk INDEX EN RECOMMENDATIONS AND SUGGESTIONS...3 CHARACTERISTICS...4 INSTALLATION...5 USE...8 MAINTENANCE...9 2 RECOMMENDATIONS

More information

TC MODULE (FFD) (with Gas Hob)

TC MODULE (FFD) (with Gas Hob) TC MODULE (FFD) (with Gas Hob) Installation Instructions REMEMBER: when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification

More information

Installation manual. Tumble dryers T4130. Compass Control

Installation manual. Tumble dryers T4130. Compass Control Installation manual Tumble dryers T4130 Type N1130 Compass Control Installation manual in original language 487 05 41 61/EN 2011.09.16 Contents 3 Contents Safety precautions... 5 Technical data... 7 Setup...

More information

MULTIPOINT BF Gas Fired Balanced Flue Water Heater

MULTIPOINT BF Gas Fired Balanced Flue Water Heater Please leave these instructions with the user MULTIPOINT BF Gas Fired Balanced Flue Water Heater User Operating, Installation and Servicing Instructions 6 720 607 090 (03.12) JS Natural Gas Main Multipoint

More information

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 HG 675 X 60 HG 675 CX 60 HG 675 CN 60 HG 675 CW 60 1 2 1. : 93/68: 90/396: 2006/95/CE: 2004/108/CE: - 1935/2004:. 2002/95/CE: RoHS 2.,.,,,,...,. (,..)..,,.,. ( ),,, ;,,.,.....,.,,,,,,...,. (..),,.,..,.,,,,

More information

Installation and Operating Manual Drying Cabinet

Installation and Operating Manual Drying Cabinet Drying Cabinet TS-4175 WW CONTENTS THIS USER MANUAL & DATA PLATE DETAILS Page 2 IMPORTANT SAFETY INSTRUCTIONS Page 3 INSTALLATION INSTRUCTIONS Page 4 OPERATING INSTRUCTIONS Page 8 MAINTENANCE INSTRUCTIONS

More information

CANOPY RANGEHOOD ONBOARD INSTALLATION INSTRUCTIONS

CANOPY RANGEHOOD ONBOARD INSTALLATION INSTRUCTIONS Congratulations on your purchase! Thank you for choosing a Sirius product. CANOPY RANGEHOOD ONBOARD INSTALLATION INSTRUCTIONS SLTC 97 900 EAN# 9351116001612 SL22 900 EAN# 9351116000660 SL7 1200 EAN# 9351116000813

More information

OPERATING AND INSTALLATION INSTRUCTIONS FOR WHISPAIR RANGEHOODS UTILISING ON BOARD FAN MOTOR UNITS

OPERATING AND INSTALLATION INSTRUCTIONS FOR WHISPAIR RANGEHOODS UTILISING ON BOARD FAN MOTOR UNITS A I R E N G I N E E R E D OPERATING AND INSTALLATION INSTRUCTIONS FOR WHISPAIR RANGEHOODS UTILISING ON BOARD FAN MOTOR UNITS CONGRATULATIONS Congratulations and thank you for choosing a Whispair rangehood.

More information

Installation plan Commercial Washing Machine PW 413 PW 418

Installation plan Commercial Washing Machine PW 413 PW 418 Installation plan Commercial Washing Machine PW 413 PW 418 To avoid the risk of accidents or damage to the machine, it is essential to read these instructions before it is installed and used for the first

More information

IMPORTANT INFORMATION. Revised Dishwasher Installation Instructions

IMPORTANT INFORMATION. Revised Dishwasher Installation Instructions IMPORTANT INFORMATION Revised Dishwasher Installation Instructions To obtain a revised copy of the entire Dishwasher User s Manual, go to www.eurotechappliances.com. SPECIAL EDITION 11-20-02 SAVE THESE

More information

ZEST HOOD. Instructions Manual.

ZEST HOOD. Instructions Manual. ZEST HOOD Instructions Manual www.rangemaster.co.uk INDEX EN RECOMMENDATIONS AND SUGGESTIONS... 3 CHARACTERISTICS... 4 INSTALLATION... 6 USE... 14 MAINTENANCE... 16 2 RECOMMENDATIONS AND SUGGESTIONS The

More information

USER MANUAL EFC60001 EFC70001 EFC90001

USER MANUAL EFC60001 EFC70001 EFC90001 USER MANUAL EFC60001 EFC70001 EFC90001 We were thinking of you when we made this product electrolux 3 RECOMMDATIONS AND SUGGESTIONS 5 CHARACTERISTICS 6 INSTALLATION 8 USE 11 MAINTANCE 12 Welcome to the

More information

en-us Use and Care Manual, Installation Instructions Washer WAT28400UC

en-us Use and Care Manual, Installation Instructions Washer WAT28400UC en-us Use and Care Manual, Installation Instructions Washer WAT28400UC Under counter (Less Desirable) If front of the appliance is covered ventilation openings must be installed. E & F are minimum area

More information

InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1

InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1 INSTALLATION, OPERATION & MAINTENANCE MANUAL InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1 Heat Controller 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100

More information

TECHNICAL INSTRUCTIONS FOR AFTER SALES ULTRA ELECTRIC PASTA COOKER

TECHNICAL INSTRUCTIONS FOR AFTER SALES ULTRA ELECTRIC PASTA COOKER TECHNICAL INSTRUCTIONS FOR AFTER SALES ULTRA ELECTRIC PASTA COOKER ULTRA ELECTRIC PASTA COOKER 1. ELECTRIC DIAGRAMS...3 1.1 PASTA COOKER...3 1.2 OPTION AUTOMATIC LIFTING...4 2. HYDRAULIC CIRCUITS...5 2.1

More information

PROPER WALL MOUNTING OF THE SUITMATE

PROPER WALL MOUNTING OF THE SUITMATE The SUITMATE Swimsuit Water Extractor has been designed and manufactured with safety as our primary consideration. Therefore, it is important that the unit be installed correctly. It is also important

More information

Merloni Elettrodomestici. Technical Fitting Manual OVENS. Language Issue/Edition Page GB /

Merloni Elettrodomestici. Technical Fitting Manual OVENS. Language Issue/Edition Page GB / GB 99-11-03/01 1-18 Index 1 WORKING AND FITTED DIMENSIONS 3 1.1 Oven size 60 cm 3 1.2 Maxioven 4 2 INSTALLING THE FITTED OVEN 5 3 FITTED GAS - INSTALLATION REQUIREMENTS 5 4 FIXING THE OVEN TO THE UNIT

More information

INSTALLATION GUIDE NZ AU

INSTALLATION GUIDE NZ AU DISHWASHER DW60U6I & DW60U2I models INSTALLATION GUIDE NZ AU 1 SAFETY AND WARNINGS 100 lb 45 kg! WARNING! Electrical shock hazard Before installing the dishwasher, remove the house fuse or open the circuit

More information

MULTIPOINT FF Room Sealed Fan-Assisted Water Heater

MULTIPOINT FF Room Sealed Fan-Assisted Water Heater Please leave these instructions with the user MULTIPOINT FF Room Sealed Fan-Assisted Water Heater User Operating, Installation and Servicing Instructions 6 720 607 160 (04.02) JS Natural Gas Main Multipoint

More information

SAFETY AND INSTALLATION MANUAL MODEL 8100

SAFETY AND INSTALLATION MANUAL MODEL 8100 SAFETY AND INSTALLATION MANUAL ENERGY RECOVERY VENTILATORS MODEL 8100 Provides year-round fresh air Recovers 77% of the apparent heating or cooling energy from the exhausted air See Warnings Page 3 Table

More information

Instructions Manual CTB CTB 9407

Instructions Manual CTB CTB 9407 Instructions Manual CTB 6407 - CTB 9407 INDEX EN RECOMMENDATIONS AND SUGGESTIONS... 3 CHARACTERISTICS... 4 INSTALLATION... 5 USE... 7 MAINTENANCE... 8 2 RECOMMENDATIONS AND SUGGESTIONS The Instructions

More information

Moisture inside the drum is due to final testing.

Moisture inside the drum is due to final testing. Safety instructions Scope of delivery depending on model Moisture inside the drum is due to final testing. Removing the transport braces Water connection depending on model The washing machine is heavy

More information

Assembly instructions

Assembly instructions Assembly instructions Important safely instruction 4 Children safety 4 Characteristics of the appliance and installation requirements 5 Installation niche features: built-in 6 Installation niche features:

More information

Fourneau. «Chambertin» «Chassagne» «Fontenay» INSTALLER'S MANUAL

Fourneau. «Chambertin» «Chassagne» «Fontenay» INSTALLER'S MANUAL Fourneau «Chambertin» «Chassagne» «Fontenay» INSTALLER'S MANUAL Appliances must be installed in a workmanlike manner in accordance with the instructions in this manual and locally applicable regulations.

More information

IMPORTANT SAFETY INSTRUCTIONS DANGER: WARNING:

IMPORTANT SAFETY INSTRUCTIONS DANGER: WARNING: IMPORTANT SAFETY INSTRUCTIONS YOUR SAFETY AND THAT OF OTHERS IS PARAMOUNT This manual and the appliance itself provide important safety warnings, to be read and observed at all times. This is the attention

More information

installation and operating instructions K224 rangehood

installation and operating instructions K224 rangehood installation and operating instructions K224 rangehood Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9 GENERAL Carefully read the following important information regarding installation safety

More information

Fourneau. «Saulieu» «Savigny» «Citeaux» INSTALLER'S MANUAL

Fourneau. «Saulieu» «Savigny» «Citeaux» INSTALLER'S MANUAL Fourneau «Saulieu» «Savigny» «Citeaux» INSTALLER'S MANUAL Appliances must be installed in a workmanlike manner in accordance with the instructions in this manual and locally applicable regulations. This

More information

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit DC Heat Recovery Unit MVHR Wholehouse heat recovery unit Stock Ref. N DC Heat Recovery Unit MVHR 443423 Installation, Maintenance & Users Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

More information

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm Safety instructions The washing machine is heavy - take care when lifting. Caution: frozen hoses may rip/burst. Do not install the washing machine in areas exposed to frost or outdoors. The washing machine

More information

Instructions for use

Instructions for use Instructions for use These instructions are also available on the website: www.kitchenaid.eu Important instructions for safety 4 Installation 6 Safeguarding the environment 6 Troubleshooting guide 7 After-sales

More information

Installation & Service Manual. Models ALF 20, 30, 40, 50, 60, 80

Installation & Service Manual. Models ALF 20, 30, 40, 50, 60, 80 Installation & Service Manual Models ALF 20, 30, 40, 50, 60, 80 IMPORTANT! Read all safety instructions before installing, using, or servicing the heater. Installation & servicing should only be carried

More information

UBGHFF60W 60cm Gas on Glass Gas Hob

UBGHFF60W 60cm Gas on Glass Gas Hob UBGHFF60W 60cm Gas on Glass Gas Hob GB [02] x 1 [03] x 2 [04] x 1 [01] x 1 [08] x 4 [05] x 2 [09] x 1 [06] x 1 [07] x 4 [10] x 4 [11] x 1 TEMPLATE TEMPLATE UBGHFF60W GB Built-in 60cm Gas on Glass Gas Hob

More information

Manual de Instrucciones Campanas Extractoras ND.3. Bedienungsanleitung Dunstabzugshauben ND.3. Instructions Manual Kitchen Hoods ND.

Manual de Instrucciones Campanas Extractoras ND.3. Bedienungsanleitung Dunstabzugshauben ND.3. Instructions Manual Kitchen Hoods ND. Manual ND.qxd 12/01/2005 17:10 Page 1 Manual de Instrucciones Campanas Extractoras ND.3 Bedienungsanleitung Dunstabzugshauben ND.3 Instructions Manual Kitchen Hoods ND.3 Manuel d instructions Hottes aspirantes

More information

MHG201 Gas Hob Manual for Installation, Use and Maintenance

MHG201 Gas Hob Manual for Installation, Use and Maintenance MHG201 Gas Hob Manual for Installation, Use and Maintenance 1 Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu

More information

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance Customer Care Department The Group Ltd. Harby Road Langar Nottinghamshire NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer

More information

Fillmore Small Pendant Assembly and Installation Instructions

Fillmore Small Pendant Assembly and Installation Instructions CAUTION: Fillmore Small Pendant Assembly and Installation Instructions BEFORE INSTALLING FIXTURE, MAKE SURE THE POWER TO THE CIRCUIT IS TURNED OFF AT THE MAIN FUSE BOX / CIRCUIT BREAKER UTILITY BOX. Important

More information

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table

More information

Installation manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta & Clarus Control

Installation manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta & Clarus Control manual W365H, W375H, W305H, W330H, W380H, W3240H, W3300H Exacta & Clarus Control 438 9200-0 06.34 Contents 3 Contents Technical data... :... 2: Transportation and unpacking... 2: Siting and floor... 3:

More information

Cooker Hood User Manual

Cooker Hood User Manual Cooker Hood User Manual HCB93042X EN 01M-8850803200-0116-02 Please read this manual first! Dear Customers! Thank you for preferring a Beko product. We hope that you get the best results from your product

More information

SIL EM SIL 24 - SIL 25

SIL EM SIL 24 - SIL 25 INFORMAZIONI COMMERCIALI PER I CONSUMATORI COMMERCIAL INFORMATION FOR THE CONSUMER INFORMATIONS COMMERCIALES POUR LE CLIENT INFORMACIONES COMERCIALES PARA EL CLIENTE HANDELSINFORMATIONEN FÜR DEN KUNDEN

More information

Installation and maintenance instructions

Installation and maintenance instructions 6304 4995 0/004 GB For installer Installation and maintenance instructions Flue gas heat exchanger WT50/60 Please read thoroughly prior to installation and maintenance. Summary About this manual This equipment

More information

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels Installation Instructions For the 18 Built-In Dishwasher and Front Color Panels Printed in USA 154232102 Before You Begin DO NOT INSTALL DISHWASHER UNTIL YOU HAVE READ ALL INSTRUCTIONS. FOR YOUR SAFETY,

More information

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS Contents Page User instructions 3-5 General 3 Fan installation 3-4 Maintenance 3 Electrical installation 5 Troubleshooting 5 Technical description 6-8 General

More information

Instructions for use and installation Cooker Hood. Istruzioni per l uso e l installazione Cappa. Mode d emploi et installation Hotte de Cuisine

Instructions for use and installation Cooker Hood. Istruzioni per l uso e l installazione Cappa. Mode d emploi et installation Hotte de Cuisine GB IT FR DE TR Instructions for use and installation Cooker Hood Istruzioni per l uso e l installazione Cappa Mode d emploi et installation Hotte de Cuisine Bedienungsanleitung und Einrichtung Dunstabzugshaube

More information

Removing shipping locks

Removing shipping locks y Safety instructions Scope of delivery Moisture in the drum is due to end inspection. Removing shipping locks Water connection l The washing machine is heavy - lift with caution. Frozen hoses can tear/burst.

More information

Prisma Plus Assembly Guide. System G

Prisma Plus Assembly Guide. System G Prisma Plus Assembly Guide System G Preface This guide proposes a procedure for assembling the Prisma Plus System G. We have designed it to help you successfully complete your first projects. It ensures

More information

INSTALLER AND OWNER GUIDE

INSTALLER AND OWNER GUIDE 5110831/03 INSTALLER AND OWNER GUIDE Model 808 Electric Heater This guide is intended to help you install and care for your Baxi Fires Division electric heater. Please read carefully before installing

More information

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans Installation and Maintenance IPX4* The EMC Directive 2014/30/EU The Low Voltage Directive 2014/35/EU 1.0 SAFETY INFORMATION

More information

ARIN THERMOSTATIC SHOWER SYSTEM

ARIN THERMOSTATIC SHOWER SYSTEM ARIN THERMOSTATIC SHOWER SYSTEM INSTALLATION INSTRUCTIONS Before installing, read entire shower system installation instructions. Observe all local building and safety codes. For the following installation

More information

INSTALL AN ELECTRIC SHOWER

INSTALL AN ELECTRIC SHOWER INSTALL AN ELECTRIC SHOWER The plumbing and wiring involved in installing an electric shower requires sound basic skills in both areas of expertise. Ensure that wiring and plumbing are properly installed.

More information

ENRGY CURB APPLICATION GUIDE FOR TPO ROOFING SYSTEMS

ENRGY CURB APPLICATION GUIDE FOR TPO ROOFING SYSTEMS 1. Introduction The ENRGY Curb mounting system is a lightweight, nonpenetrating, roof-integrated, photovoltaic (PV) mounting system designed to maintain roof integrity and maximize power density. This

More information

Closomat Lima Vita installation & user guide

Closomat Lima Vita installation & user guide Closomat Lima Vita installation & user guide design manufacture supply install service recycle Technical data The Closomat toilet MUST be installed by a competent or qualified person. Explanation of symbols

More information

Installation Instructions

Installation Instructions GE Consumer & Industrial Appliances Installation Instructions Junction Box Cover Within this user bag, you will find a junction box cover and a #10 hex head screw used to attach the junction box cover

More information

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO: WARNING Read the instructions before using the machine PRESSURE WASHER MODEL NO: JETSTAR 1750 PART NO: 7333230 OPERATION & MAINTENANCE INSTRUCTIONS LS0711 INTRODUCTION Thank you for purchasing this CLARKE

More information

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT SWING LRSWING Installation Manual Split Type Wall Mounted Air Conditioner COOL RUN C SPEED TURBO ON/OFF FAN COOL HEAT SWING SWING Rinnai Systems Models System Indoor Outdoor HSNRQ25B HINRQ25B HONRQ25B

More information

DISHWASHER INSTALLATION INSTRUCTIONS

DISHWASHER INSTALLATION INSTRUCTIONS DISHWASHER INSTALLATION INSTRUCTIONS IMPORTANT! Read all of these instructions before installing the dishwasher. AUTOMATIC HIGH LOOP The drain hose is fastened to the back of the machine at the best height.

More information

VERSAFLOW VORTEX Supplementary instructions

VERSAFLOW VORTEX Supplementary instructions VERSAFLOW VORTEX Supplementary instructions Vortex flowmeter Equipment category II 2G CONTENTS VERSAFLOW VORTEX 1 Safety instructions 3 1.1 General notes... 3 1.2 EC conformity... 3 1.3 Approval according

More information

AGA TOTAL CONTROL. Model No s: TC3 & TC5 (ROOM VENT OPTION)

AGA TOTAL CONTROL. Model No s: TC3 & TC5 (ROOM VENT OPTION) AGA TOTAL CONTROL Model No s: TC3 & TC5 (ROOM VENT OPTION) Installation Guide REMEMBER: when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance

More information

INSTALLATION, OPERATION & MAINTENANCE MANUAL

INSTALLATION, OPERATION & MAINTENANCE MANUAL CENTRAL FANS COLASIT LTD Unit 12A, Palmers Road, East Moons Moat, Redditch. Worcs. B98 0RF Tel: 01527-517200 Fax: 01527-517195 Edition 04_13 INSTALLATION, OPERATION & MAINTENANCE MANUAL CIV Fan Range Valid

More information

USER GUIDE EXPLOSION-PROOF TELEPHONES ATEX GASES AND DUSTS TYPE 227A1 IM2 FOR GROUP I MINING II 2GD FOR GROUP IIC AND IIIC GASES AND DUSTS

USER GUIDE EXPLOSION-PROOF TELEPHONES ATEX GASES AND DUSTS TYPE 227A1 IM2 FOR GROUP I MINING II 2GD FOR GROUP IIC AND IIIC GASES AND DUSTS USER GUIDE EXPLOSION-PROOF TELEPHONES ATEX GASES AND DUSTS TYPE 227A1 IM2 FOR GROUP I MINING OR II 2GD FOR GROUP IIC AND IIIC GASES AND DUSTS Comprehensive guide available on our website: www.lelas.fr

More information

User Manual. 60 cm Knob control 4 zone ceramic cooktop

User Manual. 60 cm Knob control 4 zone ceramic cooktop User Manual HHC601 60 cm Knob control 4 zone ceramic cooktop OTE: This User Instruction Manual contains important information, including safety & installation points, which will enable you to get the most

More information

60cm Integrated Turbo Extractor

60cm Integrated Turbo Extractor 60cm Integrated Turbo Extractor LAM2201 User & Installation Guide Dear Customer, Congratulations on your choice of domestic appliance which has been designed to give you excellent service. The user manual

More information

Tumble dryer PT 5137 WP PT 7137 WP. en - GB. Installation plan

Tumble dryer PT 5137 WP PT 7137 WP. en - GB. Installation plan Installation plan Tumble dryer PT 5137 WP PT 7137 WP To avoid the risk of accidents or damage to the machine, it is essential to read operating and installation instructions before installation and commissioning

More information

SERVICE MANUAL DISHWASHERS DIVA ACCESSIBILITY DISHWASHERS

SERVICE MANUAL DISHWASHERS DIVA ACCESSIBILITY DISHWASHERS SERVICE MANUAL DISHWASHERS DIVA ELECTROLUX HOME PRODUCTS S.p.A. Publication no. Spares Operations Italy Corso Lino Zanussi,30 I - 33080 PORCIA /PN (ITALY) 599 38 70-09 Fax +39 0434 394096 EN DISHWASHERS

More information

Installation Instructions for SHD Series Drawers

Installation Instructions for SHD Series Drawers Installation Instructions for SHD Series Drawers CHECK FOR CONCEALED DAMAGE FILE CLAIM WITH DELIVERING FREIGHT CARRIER Drawers manufactured by ADVANCE TABCO are designed and constructed for storage. Applications

More information

CANOPY RANGEHOOD. instruction manual V3FC60SS & V3FC90SS 12 MONTH WARRANTY

CANOPY RANGEHOOD. instruction manual V3FC60SS & V3FC90SS 12 MONTH WARRANTY CANOPY RANGEHOOD instruction manual V3FC60SS & V3FC90SS 12 MONTH WARRANTY Contents Guide to the Appliance 2 Caring for the Environment 3 Safety Information and Warnings 4 Installation Instructions 6 Operation

More information

600mm Electric Cooktop with Solid Elements

600mm Electric Cooktop with Solid Elements 600mm Electric Cooktop with Solid Elements Model: ACS6SE2 ICS6SE3 Installation and Operation Manual Congratulations on choosing one our appliances, we hope you have many reliable years of use from this

More information

LI117A Ed. 01/03 Menhir by David Lewis

LI117A Ed. 01/03 Menhir by David Lewis Menhir by David Lewis LI11A Ed. 01/03 i 1 3 1 5 g g j h A g g 3 3 3 3 1,5 190 5 1 9 8 8 5 G F 13a 13b 13a 10F 13b 10A 13a 1a 1b 1a 1b 1 1 11 11 18-1 18-5 18-18- 1 1b 1b 18-3 18-18- 1 18-8 1a 1 1 3 5 8

More information

Installation and maintenance instructions

Installation and maintenance instructions 6304 4994 03/2006 GB For installer Installation and maintenance instructions Flue gas heat exchanger WT30/40 Please read thoroughly prior to installation and maintenance. Contents Contents Contents 2 1

More information

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER CARVER - CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER 1:0 SPECIFICATIONS Water capacity Water connections Water supply 9 litres (2 gallons)

More information

Viking Installation Guide

Viking Installation Guide Viking Installation Guide Viking Range Corporation Front Street Greenwood, Mississippi 890 USA (66) 55-00 For product information, call -888-VIKING (85-6) or visit the Viking Web site at vikingrange.com

More information

USE AND CARE GUIDE WALL MOUNTED HOOD

USE AND CARE GUIDE WALL MOUNTED HOOD USE AND CARE GUIDE WALL MOUNTED HOOD MODELS: HEE92(900MM) HEE22(600MM) HEE96(600MM) HEM52(A-900MM) HEE22(F-1100MM) HEE91(A-600MM) HEE22(900MM) HEE65(900MM) HEM52(A-600MM) HEM52(A-600MM) Fig.1 Fig.2 Fig.3

More information

Libretto di Istruzioni Instructions Manual Manuel d Instructions Bedienungsanleitung Gebruiksaanwijzing Manual de instrucciones Manual de Instruções

Libretto di Istruzioni Instructions Manual Manuel d Instructions Bedienungsanleitung Gebruiksaanwijzing Manual de instrucciones Manual de Instruções Libretto di Istruzioni Instructions Manual Manuel d Instructions Bedienungsanleitung Gebruiksaanwijzing Manual de instrucciones Manual de Instruções KSEIV97X-2 INDICE CONSIGLI E SUGGERIMENTI... 4 CARATTERISTICHE...

More information

AerFlow at ::rangehoods.com is a division of kitchen::accessories U N L I M I T E D

AerFlow at ::rangehoods.com is a division of kitchen::accessories U N L I M I T E D USA COOKER HOOD USER INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS EFORE PROCEEDING. IMPORTANT: Save these Instructions for the Local Electrical

More information

Right-hand connection. 1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm

Right-hand connection. 1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm Hose and cable lengths depending on model Scope of delivery depending on model AquaäStop AquaäSecure or Left-hand connection ~ 100 cm ~ 145 cm ~ 145 cm ~ 95 cm Moisture inside the drum is due to final

More information

50cm Single Cavity Gas Cooker CZ55583 INSTALLATION AND OPERATING INSTRUCTIONS

50cm Single Cavity Gas Cooker CZ55583 INSTALLATION AND OPERATING INSTRUCTIONS 50cm Single Cavity Gas Cooker CZ55583 INSTALLATION AND OPERATING INSTRUCTIONS The product may differ from the one illustrated but the installation and operation procedure remains the same Contents Introduction

More information