Fan Blades & Accessories

Size: px
Start display at page:

Download "Fan Blades & Accessories"

Transcription

1 D46 WHEN SHOULD YOU REPLACE A PROPELLER? HERE ARE A COUPLE OCCASIONS: Propeller balance is very sensitive. All Lau props are balanced AFTER the label has been applied to the blade. Balance is subject to change from even the slightest of pressure (such as simply resting the motor and propeller assembly on the ground after disassembly from a condensing unit). This is especially true of original equipment props as they are constructed of lighter gauge material. If a puller must be used to remove a prop from a motor shaft, it is very likely that the propeller will be distorted from the pressure. For the nominal cost of a propeller vs. the cost of a new motor, it makes sense to consider replacing the props with a Conaire heavy duty replacement designed to hold its balance in the toughest of applications and ensure years of continued service. GENERAL INFORMATION The simplest form of axial fans consists of a propeller, usually with three to five aluminum blades mounted in a venture. This type of fan finds wide use in applications requiring high air volumes at low static pressures. The performance characteristics of propellers may vary in many ways. Some general guidelines are: a. Increased blade pitch increases CFM and HP b. Decreased blade pitch decreases CFM and HP c. Increasing the number of blades increases static pressure characteristics BLADE SHAPE There are only three basic important shapes which are of interest in the propeller section - round blade, wide pressure blade and narrow pressure blades: Round blades are used for free air delivery and low pressure applications; round blades are quieter Wide Pressure blades are used in most applications operating at substantial static pressures. Wide pressure blades have excellent pressure characteristics and reasonable noise levels. Narrow Pressure blades are generally used in applications where higher static pressure exists, such as multi-row coils or places where minimum axial depth is necessary. PROPELLER VIBRATION Propellers, by nature, are rather flexible and subject to vibration. Commercially available propellers will have a number of natural frequencies occurring as different parts of the propeller vibrate, or as they vibrate in different modes. Lau exercises great care in designing propellers so natural frequencies do not occur at frequencies normally found in systems. PITCH SELECTION Pitch is measured at the spider lobe Consult the chart for pitch selection to avoid motor overload Make certain that the propeller horsepower does not exceed the motor horsepower On "Free Air" type propellers, use the brake horsepower published under the RPM in the performance chart On "Condenser" type applications, where static pressure is unknown, use the brake horsepower published at.3" static pressure for the appropriate RPM PROPELLER ROTATION The direction of rotation of a propeller is determined to be clockwise (CW) or counter-clockwise (CCW) when viewed from the air discharge side The discharge side is the concave ("cupped") side of the blade "Sandbox Method" - Imagine standing in a sandbox and dropping the propeller face up or face down on the sand. Regardless of which side is up, the direction of rotation is the same as the direction required to turn the propeller into the sand

2 D47 Free Air Type Fan Blades (3 Blade) Universal Replacement Propellers with Interchangeable Hubs Typical Applications These quality Lau propellers are designed for such free air and low pressure applications as: Pedestal Fans Wall and Roof Exhausters Air Circulators Window Fans Commercial Ventilating Equipment Agricultural Ventilating Equipment Unit Heaters General Cooling/Heating Applications Features Lau free air type propellers give you these important features: 3 blade designed with pitches to interchange with most field applications Rounded blade design for maximum free air delivery with minimum noise levels Pitches available for most common horsepower and motor speeds up to 1725 RPM in both CW and CCW rotations High quality aluminum blades Interchangeable hubs from 1/4" through 3/4" bore may be attached on either intake or discharge side Each propeller clearly identified as to pitch, diameter, rotation and maximum RPM Free Air Ratings Rotation Diameter Pitch 1050 RPM 1140 RPM 1550 RPM 1725 RPM Description Brand Part Number CFM BHP CFM BHP CFM BHP CFM BHP CW 10" 27 o F1027CW Lau CCW 10" 27 o F1027CCW Lau CW 12" 23 o F1223CW Lau CCW 12" 23 o F1223CCW Lau CW 14" 23 o F1423CW Lau CCW 14" 23 o F1423CCW Lau CW 16" 23 o F1623CW Lau CCW 16" 23 o F1623CCW Lau CW 18" 23 o F1823CW Lau CCW 18" 23 o F1823CCW Lau CW 20" 23 o F2023CW Lau CCW 20" 23 o F2023CCW Lau CW o F2418CW Lau Hubs must be ordered separately

3 D48 Heavy Duty Condenser Fan Blades (3 Blade) Hubs must be ordered separately

4 D49 Heavy Duty Condenser Fan Blades (4 Blade) Hubs must be ordered separately

5 D50 Heavy Duty Condenser Fan Blades (4 Blade) Hubs must be ordered separately

6 D51 OEM Condenser Fan Blades Diameter Pitch Number of Blades Rotation Hub Location Bore I.D. Description Brand Part Number 18" 24 o 3 CW Intake 0.5" Fits FS3BA018KA, FS3BA024KA Frigidaire R 18" 30 o 4 CW Discharge 0.5" Fits FS3BA030KA, FS3BA036KA and FS3BA042KA Frigidaire R 18" 30 o 4 CW Intake 0.5" Fits FS3BA048KA Frigidaire R 24" 30 o 3 CW Intake 0.5" Fits FS3BA060KA, FS3BA060KB Frigidaire R Discharge Intake

7 Hub Type Fan Blades Typical Applications Air Moving - heating or cooling Fan Coils Freezers Refrigerators Refrigerated Display Cases Heaters Ventilators Range Hoods Small Appliances Features 5 and 6 Blade designs 5 1/2" to 10" Diameters 1/4" and 5/16" Bores CW and CCW rotations High quality aluminum blades CW rotation - hub on intake side CCW rotation - hub on discharge side D52

8 D53 Plastic Fan Blades Rotation Bore Type Bore Diameter Fan Diameter Brand Part Number C.W. Round Bore Hub.1811" 3 1/2" Fasco K-FAN6012 C.W. Round Bore Hub.1811" 4" Fasco K-FAN6011 C.W. "D" Shaped Hub.2178" 6 5/8" Fasco K-FAN Round Bore Hub.1811" 4 5/8" Fasco K-FAN "D" Shaped Hub.2178" 4 5/8" Fasco K-FAN4032 K-FAN6009 K-FAN6011 K-FAN6012 K-FAN4031 K-FAN4032 Push Nut For Fan Blades - Used With K-Line Motors Fits Bore Diameter Brand Part Number.1811" Fasco K-NUT

9 D54 Hex / Round Hubs

SOS Multi-Horsepower Outdoor Condenser Fan Motor

SOS Multi-Horsepower Outdoor Condenser Fan Motor SOS Multi-Horsepower Outdoor Condenser Fan Motor Slim Stack # 03458 Wizard fits many 1/3 HP installations that will not accept competitor s motors. Wide range motor that will run at any fan load from 1/6

More information

Introduction to Fans. The Basics of Fan Principles and Terminology

Introduction to Fans. The Basics of Fan Principles and Terminology Introduction to Fans The Basics of Fan Principles and Terminology Airflow Principles A fan is a rotating device that creates pressure differential that results in air movement Pressure rise in a fan Downstream

More information

Digi-Motor. ECM for Commercial Refrigeration. Toll Free (800) Fax (631)

Digi-Motor. ECM for Commercial Refrigeration. Toll Free (800) Fax (631) Digi-Motor Azure Direct Drive Motor Azure Condenser Fan Motor Azure 3.3" Commercial Refrigeration Evaporator Fan Motor ECM for Commercial Refrigeration Fan/Motor System Made in USA Case Motor IP55 Rated

More information

Selecting the Correct Fan

Selecting the Correct Fan Selecting the Correct Fan Ryan B. Johnson Air Purification Company Sales Engineer Member, ASHRAE Pikes Peak Chapter rjohnson@airpurificationcompany.com 1 Your Speaker circa 1998 Fan Types Applications

More information

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS 036-21096-001 (0101) SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The

More information

ACME MIAMI. Product Catalog

ACME MIAMI.   Product Catalog ACME www.acmemiami.com Product Catalog Contents Defrost Heaters... 1 Flexible Bend-to-Fit for Coils & Condensate Pans 700 Series and Ball Bearing Motor Kits... 2 & 3 Commercial Refrigeration Motor Kits

More information

DUST COLLECTORS & DOWNDRAFT TABLES. A division of BLOWERS

DUST COLLECTORS & DOWNDRAFT TABLES. A division of BLOWERS DUST COLLECTORS & DOWNDRAFT TABLES A division of SOLUTIONS BELT-DRIVEN RSC/RSO RSC/RSO blowers are typically installed before the dust collector and are used for the transportation of materials. They develop

More information

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size) www.blowtech.in we make air move Blowtech Air Devices Pvt. Ltd. was founded in 1988 and quickly established

More information

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST S Model TCBS CATALOG AX220 May 2013 TubeaxialFans Model TCBS The Twin City Fan & Blower model TCBS is a belt driven tubeaxial fan that is

More information

Ducted Propeller. Airflow Volume

Ducted Propeller. Airflow Volume Total Pressure Radial-Blade Centrifugal Tubeaxial Backward-inclined Airfoil Centrifugal Forward-curved Centrifugal Ducted Propeller Airflow Volume Figure 2: Forward-Curved Centrifugal Fan

More information

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

A. General: Refer to paragraph entitled SUBMITTAL in Section Include the following data: SECTION 15860 - FANS PART 1 - GENERAL 1.01 RELATED DOCUMENT A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR MECHANICAL

More information

Marley X7 Fan USER MANUAL DESIGNED FOR INDUCED-DRAFT COOLING TOWER APPLICATIONS

Marley X7 Fan USER MANUAL DESIGNED FOR INDUCED-DRAFT COOLING TOWER APPLICATIONS USER MANUAL Marley X7 Fan DESIGNED FOR INDUCED-DRAFT COOLING TOWER APPLICATIONS M2010-1234A ISSUED 3/2012 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. Fan Components 1

More information

ENGINEERING LETTER 4

ENGINEERING LETTER 4 ENGINEERING LETTER 4 The New York Blower Company 7660 Quincy Street, Willowbrook, Illinois 60521-5530 TEMPERATURE AND ALTITUDE AFFECT FAN SELECTION INTRODUCTION Fan performance changes with the density

More information

These pumps offer unique capabilities which are either not available or costly to acquire with other pumps.

These pumps offer unique capabilities which are either not available or costly to acquire with other pumps. Flexible Impeller Pumps From the inventors of the self-priming flexible impeller pump Industrial Flexible Impeller Pumps Hygienic Flexible Impeller Pumps Flexible Impeller Pump Accessories These pumps

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

THREE-WAY HEAT SAVER/VENTILATOR

THREE-WAY HEAT SAVER/VENTILATOR BULLETIN 673 December 2009 THREE-WAY HEAT SAVER/VENTILATOR Modulated Damper Control System Operates in Supply, Exhaust, Heat Saver and Mixed-Air Modes Models RREH & RRES Three-Way Heat Saver/Ventilator

More information

Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems.

Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems. Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems. The DRY-30 Series Dehumidifiers, like all equipment manufactured by DryAire Systems combines more standard features

More information

Fans: Features and Analysis

Fans: Features and Analysis Technical Development Program COMMERCIAL HVAC EQUIPMENT Fans: Features and Analysis PRESENTED BY: Michael Ho Version 1.2 Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Section

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be

More information

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems.

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems. Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems. The DRY-40A Series Dehumidifiers, like all equipment manufactured by DryAire Systems combines more standard features

More information

Glossary of Terms Laboratory & Fume Exhaust Fans

Glossary of Terms Laboratory & Fume Exhaust Fans Glossary of Terms Laboratory & Fume Exhaust Fans ACTUATOR, 2-POSITION SPRING RETURN A spring return actuator generally used to control the isolation dampers below the fans. This actuator allows for fully

More information

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/ 1 of 3 Cooling Capacity [Btuh] 24,800 * Condensing Unit SEER: 13.0 ** Condensing Unit CFM: 1,600 Condenser Fan No./Type: 1/CENTRIFUGAL Diameter x Width [in]: 10x10 Drive: Adjustable Belt Motor HP: 0.5

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS A. Placement within a mechanical room is required for all major mechanical equipment. Only small units may be roof-mounted, and shall be made as inconspicuous

More information

UEE11 Electrotechnology. Training Package. UEENEEJ107A Air conditioning and refrigeration systems, major components and associated equipment SAMPLE

UEE11 Electrotechnology. Training Package. UEENEEJ107A Air conditioning and refrigeration systems, major components and associated equipment SAMPLE UEE Electrotechnology Training ackage UEEEEJ07A Air conditioning and refrigeration systems, major components and associated Learner Workbook Version Training and Education Support Industry Skills Unit

More information

USER GUIDE. This manual covers the description, cautions, operation and maintenance of Super Vac confined space electric ventilators CONTENTS

USER GUIDE. This manual covers the description, cautions, operation and maintenance of Super Vac confined space electric ventilators CONTENTS VENTILATOR USER GUIDE MODEL HF124 USER GUIDE This manual covers the description, cautions, operation and maintenance of Super Vac confined space electric ventilators Please take the time to read this manual

More information

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions. Microchannel REMOTE AIR COOLED CONDENSER Technical Bulletin: MXCC_004_030817 Products that provide lasting solutions. Krack s new Microchannel Remote Air Cooled Condenser incorporates a new patented modular

More information

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS Cooling Capacity from 115,000 to 670,000 Btu/hr Btu/hr Smartwise Innovations... Towards Green, Quality & Reliability Solutions SERIES INTRODUCTION

More information

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ E3FB090/E1FB120/F3EH090 & 120 7-1/2 & 10 NOMINAL TONS (60 HZ) 7 & 9 NOMINAL TONS (50 HZ) (9.0-9.2 EER) 208/230/460 VOLT ONLY 208/230 VOLT ONLY DESCRIPTION YORK has

More information

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers 60 HZ Convertible Air Handlers Model: Series 2 Air Handlers 1.5-3 ton Standard Coil Black Epoxy Coil GAF2A0A18S11SE GAF2A0A18S11EE

More information

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW INSTALLATION INSTRUCTIONS RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW 92-106595-01-00 TABLE OF CONTENTS Introduction.......................................

More information

DAE Systems. Fan Selection Guide. Section 1: Terminology

DAE Systems. Fan Selection Guide. Section 1: Terminology DAE Systems Fan Selection Guide Section 1: Terminology CFM : Cubic Feet per Minute Technical Terms This refers to the amount of air a fan is able to move. Pressure Inches of water is a common method of

More information

40 RM/RMS Packaged Air-Handling Units

40 RM/RMS Packaged Air-Handling Units ConcepcionCarrier Air conditioning Company Philippines 40 RM/RMS 008034 Packaged AirHandling Units INSTALLATION MANUAL, STARTUP & SERVICE INSTRUCTIONS Contents Page Page Safety Considerations 1 40RM Physical

More information

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004) High Plume Blowers Suggested Specification Section 15500 (Master Format 1996) Suggested Specification Section 23 38 16 (Master Format 2004) PART 1 GENERAL 1.01 WORK INCLUDED High Plume Laboratory Exhaust

More information

A. Codes and Standards that are Standard at the University:

A. Codes and Standards that are Standard at the University: PART 1: GENERAL 1.01 Purpose: 1.02 References: 1.03 Requirements: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The

More information

PUMPS AND PROP AGITATORS

PUMPS AND PROP AGITATORS PUMPS AND PROP AGITATORS Shown with optional telescoping legs. MAGNUM LAGOON PUMPS Balzer Magnum Lagoon Pump features the Balzer vertical positioned Super 150 Impeller, 19 horizontal prop, patented chopping

More information

Modular Multi-position Air Handler

Modular Multi-position Air Handler Modular Multi-position Air Handler Air Handler - Convertible Model: Series 2 Air Handler 3 ton with high efficiency motor GAF2A0A36M31SA PUB. NO. 22-1862-01 Features and Benefits Unique Cabinet Design

More information

AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS

AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS Twin City Fan INDUSTRIAL PROCESS AND COMMERCIAL VENTILATION SYSTEMS AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS FPAC FPMC FPDA CATALOG AX351 JULY 2001 WWW.TCF.COM

More information

Fan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10

Fan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10 Fan Laws Keith Miller Samuel Tepp Associates Paul Cenci, P. E.-Principal Brian England-Principal Basic Terms CFM - Cubic Feet per Minute, volume (amount) of air being moved SP - Static Pressure, resistance

More information

Ship-Wide Ventilation Systems

Ship-Wide Ventilation Systems INSPIRED BY COMFORT Ship-Wide Ventilation Systems Protecting & Cooling Machinery Spaces for Leisure, Commercial & Military Vessels Specification Sheets for: Mist Eliminators, Blowers & Fans, Fire & Smoke

More information

COMMERCIAL HVAC AIR-HANDLING EQUIPMENT. Fans in VAV Systems

COMMERCIAL HVAC AIR-HANDLING EQUIPMENT. Fans in VAV Systems COMMERCIAL HVAC AIR-HANDLING EQUIPMENT Fans in VAV Systems Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection and application topics.

More information

Old style propeller New style propeller

Old style propeller New style propeller Quieter fans Problem: There are lots of fans to move and mix air throughout the Station and also for cooling electrical equipment. Individually each fan is reasonably quiet; however, all of these fans

More information

SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT. Fans, Heaters & Controls

SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT. Fans, Heaters & Controls SIOUX STEEL COMPANY GRAIN CONDITIONING EQUIPMENT Fans, Heaters & Controls 1 GRAIN CONDITIONING EQUIPMENT SIOUX STEEL COMPANY Innovative Solutions Manufactured By A Family-Owned Company With A ENGINEERING

More information

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual Midea reserves the right to discontinue, or change specification or designs at any time without notices and without

More information

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual Air Storm 18 Fiberglass Fan Installation and Operation Manual Table of Contents GrowerSELECT General Page...3 Safety...4 Warning Labels...4 Installation...5 Operation Safety...5 Maintenance Safety...5

More information

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax WIBR SERIES Unit Coolers - Technical Catalog 4492 Hunt St - Pryor, OK 74361-918.825.7222 - Fax 800.264.5329 - www.century-refrigeration.com Features/Applications Century Refrigeration s WIBR Series Unit

More information

Modular Supply Make-Up Air Unit

Modular Supply Make-Up Air Unit Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features

More information

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A Publication No. WT-CSX-0616A Central Station Air Handling Units Complete HVAC Capability Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels

More information

Adding More Fan Power Can Be a Good Thing

Adding More Fan Power Can Be a Good Thing This article was published in ASHE Journal, May 14. Copyright 14 ASHE. Posted at www.ashrae.org. This article may not be copied and/or distributed electronically or in paper form without permission of

More information

SECTION AIR HANDLING UNIT

SECTION AIR HANDLING UNIT SECTION 15800 - AIR HANDLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Basic Requirements: Provisions of Section 15010, BASIC MECHANICAL REQUIREMENTS, and Section 15030, ELECTRICAL REQUIREMENTS FOR

More information

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet 3020/3120 Series Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet A Crane Co. Company DEMING PUMPS Introducting Deming 3020/3120 Series End-Suction

More information

Air Storm Fans. Air Storm 24 Fiberglass Fan Installation and Operation Manual

Air Storm Fans. Air Storm 24 Fiberglass Fan Installation and Operation Manual Air Storm 24 Fiberglass Fan Installation and Operation Manual Hog Slat Inc. Newton Grove, NC USA May 2015 Table of Contents GrowerSELECT General Page...3 Safety...4 Warning Labels...4 Installation...5

More information

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Construction Standards Page 233423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified

More information

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS 550.23-TG5Y (893) CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L2EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility.

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage. LN series Horizontal Split Case Pumps Double Volute. Single Stage www.sterlingpumps.com.au LN series Sizes: 6 to 42 Capacity to 12,500 m³/h Heads to 190 metres A rugged, single stage, double volute horizontal

More information

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP DS series Industrial End Suction Pumps ISO/DP 5199 www.sterlingpumps.com.au DS series Capacities from: Heads from: 340 to 5,680 m3/h (1,500 to 25,000 USPGM) 21 to 106 metres (70 to 350 feet) Power range

More information

KIC Air Curtains. Technical Guide

KIC Air Curtains. Technical Guide TGKIC-3 KIC Air Curtains Technical Guide AIR PERFORMANCE AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. King certifies that the air curtains shown herein are licensed to bear the AMCA seal. The

More information

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges. Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The

More information

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2 INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 2 (PNEUMATIC CONTROL AND HYDRAULIC CONTROL) PUBLICATION No. 01900 Revision 2 Printed in Canada 1.1 INTRODUCTION Thank you

More information

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 canbepositionedinupto12differentpositionsandsuspended

More information

AMERICAN COOLAIR CORPORATION. Greenhouse Ventilation Systems. Farm Products Division

AMERICAN COOLAIR CORPORATION. Greenhouse Ventilation Systems. Farm Products Division AMERICAN COOLAIR CORPORATION Greenhouse Ventilation Systems Farm Products Division AL Aluminum Greenhouse Fan American Coolair s AL all-aluminum fans are the answer to concerns about rust and corrosion

More information

Evaluation Report 509

Evaluation Report 509 Printed: June 1987 Tested at: Lethbridge ISSN 0383-3445 Group 5i Evaluation Report 509 Prairie Pride TR-36 Series Ventilation Fans A Co-operative Program Between ALBERTA FARM MACHINERY RESEARCH CENTRE

More information

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1

INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1 INSTALLATION AND SERVICE MANUAL FOR THE SERIES 2000 & SERIES 3000 FAN SERIES GEN 1 (PNEUMATIC CONTROL AND HYDRAULIC CONTROL) PUBLICATION No. 01524 Revision 15 Printed in Canada 1.1 INTRODUCTION Thank

More information

7697 Snider Road, Mason, OH Telephone:

7697 Snider Road, Mason, OH Telephone: OEM and Industrial Air Handling Specialist ENGINEERING DATA 7697 Snider Road, Mason, OH 45040-9135 Telephone: 513-573-0600 Visit us at www.cincinnatifan.com for more information. Catalog #ENG-203 Supersedes

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

HVAC REPAIR/REPLACEMENT 07/18/12 SECTION HVAC - MAJOR EQUIPMENT

HVAC REPAIR/REPLACEMENT 07/18/12 SECTION HVAC - MAJOR EQUIPMENT SECTION 15300 - HVAC - MAJOR EQUIPMENT PART 1 - GENERAL 1.1 MECHANICAL GENERAL A. Section 15010 is applicable. PART 2 - PRODUCTS 2.1 FANS A. General: 1. All fans shall bear the AMCA Certified Performance

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS MODEL 652A MODEL 654A MODEL 652A MODEL 651A MODEL 653A AURORA 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS WWW.AURORAPUMP.COM 2 AURORA 650 Series Single Stage Solids Handling Pumps Capacities to 2000

More information

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 25,240* Design CFM: 800 Seasonal

More information

14" - 24" CLASSIC Direct Drive Fans

14 - 24 CLASSIC Direct Drive Fans 14" - 24" CLSSIC Direct Drive Fans T14F T16F, G T18F, G T24F, G R R Ventilation Systems 14" - 24" Fiberglass Fans 16" - 24" Galvanized Fans Page 1 of 11 USER'S MNUL and INSTLLTION GUIDE TBLE OF CONTENTS

More information

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons 560.20-TG1Y (388) EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons Each circuit includes a fully hermetic compressor with a crankcase

More information

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Internal ridged board 1 x 1.5 foil face installation shall be installed on roof, walls and base of casing. A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall

More information

Optiline Fan Array. The optimum number of fans for every application. The Optimum in Sound Energy Size Redundancy Reliability.

Optiline Fan Array. The optimum number of fans for every application. The Optimum in Sound Energy Size Redundancy Reliability. Optiline Fan Array The optimum number of fans for every application The Optimum in Sound Energy Size Redundancy Reliability Energy Labs was before was cool Introduction Energy Labs was the first manufacturer

More information

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You.

TGIF-1. Indirect Fired Heating Systems. Technical Guide for: IF Indoor Installations. IFW Outdoor Installations. Applied Air. Keeps You. TGIF- Indirect Fired Heating Systems Technical Guide for: IF Indoor Installations IFW Outdoor Installations Applied Air Keeps You Warm Indirect Fired Heating Systems Technical Guide In the business of

More information

INDUSTRIAL BLOWERS. With over 70 years of experience and expertise our fans will ensure your projects are a success.

INDUSTRIAL BLOWERS. With over 70 years of experience and expertise our fans will ensure your projects are a success. BLOWERS With over 70 years of experience and expertise our fans will ensure your projects are a success. ABOUT OUR PARTNERSHIP has been representing Chicago Blower Corporation (USA) since 2004, offering

More information

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation Industrial Space Heating Direct Gas-Fired Heating Greenheat 00% Outdoor Air Greenheat 50/50 Recirculation 80/0 Recirculation March 008 Product Overview Industrial Space Heating Greenheck s space heating

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 233423 - HVAC POWER VENTILATORS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 PERFORMANCE REQUIREMENTS A. Operating

More information

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source! Propeller Fans Industrial And Commercial Fans Belt And Direct Drive Your Clean Air Source! MODEL PVL EXHAUST FANS Application Economical fans for use in kitchens, laundries, taverns, bakeries and also

More information

Twin City Fan & Blower

Twin City Fan & Blower Twin City Fan & Blower BULLETIN AX351 July 2001 AXICO ANTI-STALL Controllable Pitch-In-Motion and Adjustable Pitch-At-Rest Vaneaxial Fans Types FPAC, FPMC, FPDA A complete product bulletin including performance

More information

Owners Manual. SM-HP A SM-HP8-10 Meter. Manual D

Owners Manual. SM-HP A SM-HP8-10 Meter. Manual D DuraCore TM Fan Owners Manual SM-HP8-64-360A SM-HP8-10 Meter Manual 9-1473D 1 4 5 7 8 9 6 MONEL HARDWARE 7 8 9 STAINLESS HARDWARE 00 FAN BLADE FAN HUB 3 Fan Components Marley Order No. Trial Pitch Angle

More information

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability- A Series Unit Coolers - Technical Catalog Product Benefits: T 3 $ Adaptability- Century systems go where others can t. Your Century system is engineered to meet your specific project application and job

More information

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ) Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper

More information

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

Energy Guide. Fan Efficiency Grades. FEG Ratings. July Energy Guide Fan Efficiency Grades s July 2013 Certified Fans Location Mounting Airflow Application Drive Type Impeller Type Performance Model Outdoor Indoor Roof Curb Base/Floor Hanging Wall Ceiling Mounted

More information

CPO N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. ASME/ANSI B73.1 Chemical Process Pump. Springer Pumps, LLC

CPO N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. ASME/ANSI B73.1 Chemical Process Pump. Springer Pumps, LLC N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO ASME/ANSI B73.1 Chemical Process Pump Tel: 866-777-66 Horizontal Split Case For more than 6 years the name Ruhrpumpen TM has been synonymous worldwide

More information

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE

ultra quiet fan USER MANUAL INSTALLATION OPERATION MAINTENANCE USER MANUAL ultra quiet fan INSTALLATION OPERATION MAINTENANCE Z0414808 rev A ISSUED 02/2014 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. safety and handling Safety Warning

More information

Smart Comfort Solutions HIGH VELOCITY DRUM FANS

Smart Comfort Solutions HIGH VELOCITY DRUM FANS Smart Comfort Solutions HIGH VELOCITY DRUM FANS Direct Drive Drum Fans Direct Drive drum fans are great for heavy duty air circulation in light duty commercial applications where an economical solution

More information

ISOLATED DIRECT DRIVE PLENUM FAN (IDDP)

ISOLATED DIRECT DRIVE PLENUM FAN (IDDP) Our Expertise, Your Air-Moving Solution ISOLATED DIRECT DRIVE PLENUM FAN (IDDP) PART# 0601710001_rev_A INSTALLATION, OPERATION & MAINTENANCE MANUAL Please read and save these instructions for future reference.

More information

for Refrigeration Applications

for Refrigeration Applications A Regal Brand for Refrigeration Applications Direct Drop-In Replacement Supermarket Case Evaporator Fan Motor Advanced ECM Design Cast Iron 15 Leads Lyall Plug UL/CUL approved E128044 Up to 65% Efficiency

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. ASME/ANSI B73.1 Chemical Process Pump

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. ASME/ANSI B73.1 Chemical Process Pump N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO ASME/ANSI B73.1 Chemical Process Pump Horizontal Split Case For more than 6 years the name Ruhrpumpen TM has been synonymous worldwide with innovation

More information

CR1 Series Triton Corrosion Resistant Washdown Heaters

CR1 Series Triton Corrosion Resistant Washdown Heaters CR1 Series Triton Corrosion Resistant Washdown Heaters Ruffneck CR1 Triton Series is a new generation of NEMA 4X corrosion-resistant washdown heaters. The first UL listed Type 4X heater with models ranging

More information

FX5 Series Explosion-Proof Electric Air Heaters

FX5 Series Explosion-Proof Electric Air Heaters FX5 Series Explosion-Proof Electric Air Heaters Ruffneck FX5 heaters are C UL US certified for use in hazardous locations. They are designed for the harshest environments such as: dry indoor industrial

More information

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED (491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes

More information

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork. SECTION 15855 AIR HANDLING UNITS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15240 - Vibration Isolation. 2. 15885 - Air Filtration Equipment. 3. 15890 - Ductwork. 1.02 REFERENCES A. Air Moving

More information

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

Split System Heat Pumps

Split System Heat Pumps Split System Heat Pumps Split System Heat Pumps 7 1/2-20 Tons - 60 Hz Air Handlers 5-20 Tons - 60 Hz SSP-PRC001-EN Introduction Split System Heat Pump Units... Designed With Your Needs In Mind. The Trane

More information

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator

More information

Replacement Fractional Horsepower Motors

Replacement Fractional Horsepower Motors TOTALINE UNIVERSAL AFTERMARKET MOTORS Replacement Fractional Horsepower Motors for the HVAC/R Industry TRUST TOTALINE ON YOUR TRUCK DIRECT DRIVE BLOWER MOTORS Totaline Direct Drive Blower Motors are three

More information

Centrifugal Blower. Backward/Aerofoil Curved.

Centrifugal Blower. Backward/Aerofoil Curved. Centrifugal Blower Backward/Aerofoil Curved www.humidin.com Centrifugal Blower Backward/Aerofoil Curved When Quality Speaks For Itself As a leading manufacturer of Centrifugal Blower Backward/Aerofoil

More information