CONDOR-H (horizontal) / CONDOR-V (vertical)
|
|
- Abner Haynes
- 6 years ago
- Views:
Transcription
1 Refrigeration & limate omponents Solutions 3.1 TY-EN 3.1- / -18 ONDOR-H (horizontal) / ONDOR-V (vertical) n Applications ensure cooling, condensation and storage of refrigerant in refrigerating and air conditioning installations. They also allow storage of the refrigerant, in order to compensate volume variations due to the opening and closing sequences of the expansion valve. In O² subcritical installations, they can be used as a liquid receiver with exchanger to keep temperature and pressure stable. Heat exchange is carried out by a water circulation inside a very high performance finned copper tubing coil. Energy recovery: The use of a water cooled condenser ONDOR allows to heat with lower costs water circulating in the exchanger (technical hot water...) n Functional features n advantages Products are compatible with Fs, HFs, HFs, O s, as well as with their associated oils and additives. Products are designed for use of non-hazardous refrigerants from group of PED 1/68/EU. To use components with fluids of the hydrocarbon group 1 Propane R9, Butane R6, Isobutane R6a, Propylene R17 with HFOs and for a RANKINE organic cycle application, contact technical department. Product classification in E categories is done with the PED 1/68/EU table, corresponding to a volume-based selection. Hermetically sealed outer steel enclosure with paint to ensure a high resistance to corrosion. Two ranges of water cooled condensers receivers for an installation and an operation in horizontal position for ONDOR-H and in vertical position for ONDOR-V. They are fitted with fastening means suited to their volume and to their weight. They can function with tap water, river water, tower water (treated or not), with glycol water and with refrigerants and heat transfer fluids. Presence of a 3/8 NPT boss on the model ONDOR-V 5, for mounting of safety elements in accordance with the standard EN Maximum working pressure 6 bar. with receiver are supplied perfectly clean and dried. They offer both following connection possibilities for the refrigerant: Outside of the to screw. Inside of the to braze. Heat exchangers made of finned copper for very high performance. Low water consumptions. Low pressure drop on water. A wide range of accessories is available: Rotalock stop valves, with to screw or to braze. Rotalock with possibility of diameter reductions and with to braze. Reduction of the quantity of the refrigerant in the circuit compared to installations with air cooled condensers. Possible customization on demand: Depending on the application, can transform its water cooled condensers in subcoolers.
2 3. Refrigeration & limate omponents Solutions TY-EN 3.1- / -18 ONDOR-H (horizontal) / ONDOR-V (vertical) n Warning Before selecting or installing any component, please refer to the chapter - WARNING. n General assembly precautions The installation of a component in a refrigeration system by a skilled professional, requires some precautions: Some are specific to each component, and in this case, they are specified in the REOMMENDATIONS SPEIFI part defined hereafter ; Other are general to all components, they are presented in the chapter 115 GENERAL ASSEMBLY PREAUTIONS. The recommendations relating to the components for the subcritical O applications are also developed in chapter 115 GENERAL ASSEMBLY PREAUTIONS. n Recommendations specific to the water cooled condenser ONDOR The water cooled condensers must be installed at the discharge of the compressors, horizontally for models ONDOR-H, vertically for models ONDOR-V and in both cases, with their feet brackets at the bottom. For optimal operation, refrigerant and water flow directions should be respected ( IN tag at the inlet of each circuit). If sizing of the receivers is performed on the basis of the total refrigerant load, it is imperative to select receivers with an internal volume % bigger, so that the gas reserve is always above the liquid level. It is essential to ensure a water circulation before any handling on the refrigerating circuit (risk of freezing). Water circulating in the heat exchangers can freeze: - when the installation is running, if the refrigerant pressure decreases - when the installation is stopped, if the ambient temperature drops. It is therefore recommended to install appropriate frost protection devices. Be sure to maintain a good cleanliness of the water circuit using appropriate and regularly changed filters. Use of see water strictly prohibited. The of the water cooled condensers ONDOR have an external screw thread (sketch 1) allowing the assembly of isolating valves or Rotalock, and an internal bore (sketch ) allowing the brazing of a pipe. 1 Outside of the to screw Inside of the to weld or to braze
3 Refrigeration & limate omponents Solutions 3.3 TY-EN 3.1- / -18 ONDOR-H (horizontal) n Quick selection table Gas inlet R1 Outside of to screw UNF ONDOR-H 15 3/ 3/8 3/ 3/8 1/ ODF 1,5,1,1,9,7 ONDOR-H 5 3/ 3/8 3/ 3/8 1/ ODF,6,,,9,7 ONDOR-H 5 1 1/ 3/ 3/8 1/ ODF 5,,5,6,9,3 ONDOR-H / 3/ 3/8 1/ ODF 7,5,3,1,1,1 ONDOR-H 1 1 1/ 3/ 3/8 1/ ODF 9,9,,16 6,3,1 Refrigerant RA ; Δt1 = 5 K ; Inside of to braze ODF Δt1 = ondensing temperature - Water inlet temperature Liquid outlet R Outside of to screw UNF Inside of to braze ODF Water inlet W1 and outlet W mm ondensation capacity Qk kw Water flow m 3 /h Water pressure drop bar Maximum storage L Volume of refrigerant Without subcooling L Dimensions mm Ø1 Ø Ø3 L1 L L3 L L5 L6 E1 E E3 E E5 E6 ONDOR-H 15 11, 18 x Ø6,5 x ONDOR-H 5 11, 18 x Ø6,5 x ONDOR-H 5 15, 156 x Ø9 x 5, / ONDOR-H 75 11, 18 x Ø6,5 x ONDOR-H 1 15, 156 x Ø9 x 5, / L1 L L3 E E E1 W1 W R1 R 5 E3 Ø L6 E6 1 Ø3 L5 E5 L
4 3. Refrigeration & limate omponents Solutions TY-EN 3.1- / -18 ONDOR-H (horizontal) Volume V L Maximal working pressure PS bar Heat exchanger maximal working pressure PS Ech. bar Maximal working temperature TS maxi Minimal working temperature TS mini Working temperature ONDOR-H 15 3, / I ONDOR-H 5 3, / I ONDOR-H 5 5, / II ONDOR-H 75, / I ONDOR-H 1 7, / II lassification by volume, according to PED 1/68/EU (refer to chapter ). TS BT E ategory n Example of selection of a ONDOR water cooled condenser The sizing of a product implies for the buyer to take into account the conditions under which the product will be used (temperature - pressure refrigerant oil external environment). The values of the selection tables proposed in the catalogue match accurate test conditions. Installation operating with RA under the following conditions : Qk x = 7 kw Tk = Tl1 = > Δt1 = - = K Maximum water flow = 5 l/h Normal city water Which water cooled condenser ONDOR to choose? 1 Make corrections according to the water and the refrigerantes: orrection according to fouling factor Fe (refer to page 3.5) - 1- orrection according to refrigerant Fr (refer to page 3.5) Result: Qk = Qk x x Fe x Fr = 7 kw Report the capacity to the quick selection table, page Report the maximum water flow to the quick selection table, page 3.5 Select the ONDOR H model. Result: ONDOR H -1 > Δt1 = 18K ONDOR H -75 > Δt1 = K ONDOR H -5 > Δt1 = 5K hapter «Abbreviations and units» (refer to chapter 113).
5 Refrigeration & limate omponents Solutions 3.5 TY-EN 3.1- / -18 ONDOR-H (horizontal) According to the type of water available, the condensation capacity (Qkx) of the installation should be corrected in accordance to the fouling factor by the formula: Qk = Qkx x Fe Water type Fouling factor m.k / W orrection factor Fe Normal city water , Treated tower water , Untreated tower water ,19 River water ,19 Glycol water below % ,19 Glycol water below 7 % ,56 According to the type of refrigerant used, the condensation capacity (Qkx) of the installation should be corrected in accordance to the following Fr factor by the formula: Qk = Qkx x Fr Refrigerant orrection factor Fr RA / R57 1, R / R1A / R7F,9 R13a / R7,85 n Quick Selection Table apacity kw ONDOR-H 1 ONDOR-H 75 ONDOR-H 5 ONDOR-H 5 ONDOR-H 15 15K Δt1 5K 6 8 Water flow l/h
6 3.6 Refrigeration & limate omponents Solutions TY-EN 3.1- / -18 ONDOR-H (horizontal) n Spares parts and options 3 1 ONDOR H (S) - 75(S) - 1(S) 5(E) - 75(E) - 1(E) (E) = Inlet, (S) = Outlet Flat gasket for valves and ROTALOK Y / et 3/8 Y / ØA ØB ONDOR H (S) - 75(S) - 1(S) (S) - 75(S) - 1(S) 5(E) - 75(E) - 1(E) (E) = Inlet, (S) = Outlet ROTALOK, gasket included ØA outlet ODF connection ØB fixing UNF connector Y 17 1/ 3/ Y 171 3/8 3/ Y 17 1/ 1
7 Refrigeration & limate omponents Solutions 3.7 TY-EN 3.1- / -18 ONDOR-H (horizontal) n Spares parts and options B A ONDOR H (S) - 75(S) - 1(S) (S) - 75(S) - 1(S) 5(E) - 75(E) - 1(E) (E) = Inlet, (S) = Outlet ROTALOK valve with connection to solder, gasket included ØA outlet ODF valve ØB fixing UNF valve Y / 3/ Y /8 3/ Y / 1 B A ONDOR H (S) - 75(S) - 1(S) (S) - 75(S) - 1(S) 5(E) - 75(E) - 1(E) (E) = Inlet, (S) = Outlet ROTALOK valve with connection to screw, gasket included ØA outlet SAE valve ØB fixing UNF valve Y / 3/ Y /8 3/ Y / 1 Y 3711 Y 371 ONDOR H Description Y 3711 Support feet 5-1 Y 371 Support feet n Weights and packaging With packaging Unit weight kg Without packaging Packaging number of pieces ONDOR-H 15 5,65 5, 1 ONDOR-H 5 8,65 8, 1 ONDOR-H 5 11,3 11, 1 ONDOR-H 75 7,65 7, 1 ONDOR-H 1 1,3 1, 1
8 3.8 Refrigeration & limate omponents Solutions TY-EN 3.1- / -18 ONDOR-V (vertical) n Selection table Gas inlet R1 Outside of to screw UNF Inside of to braze ODF Liquid outlet R Outside of to screw UNF Water inlet W1 and outlet W mm ondensation capacity ONDOR-V 1 3/ 3/8 3/ 3/8 1/ ODF 1,11,1,1, 1, ONDOR-V 15 3/ 3/8 3/ 3/8 1/ ODF 1,5,1,1,7 1,8 ONDOR-V 3/ 3/8 3/ 3/8 1/ ODF,39,,,7 1,7 ONDOR-V 5 1 1/ 3/ 3/8 1/ ODF,9,3,7 6,1,5 ONDOR-V 1 1 1/ 5/8 1 1/ 1/ ODF 9,8,5,5 7,7,5 ONDOR-V 1 1 1/ 5/8 1 1/ 1/ ODF 1,56 (),8,53 3,1,7 ONDOR-V 5 1 3/ 7/8 1 1/ 5/8 G 3/ M 5,5 () 1,6,37 13, 3,5 Refrigerant RA ; Δt1 = K ; () Refrigerant RA ; Δt1 = 5 K ; Δt1 = ondensing temperature - Water inlet temperature Inside of to braze ODF For more details on the selection of condensers, refer to pages 3-1 to Qk kw Water flow m 3 /h Water pressure drop bar Maximum storage L Volume of refrigerant Without subcooling L
9 Refrigeration & limate omponents Solutions 3.9 TY-EN 3.1- / -18 ONDOR-V (vertical) Drawing Nb Dimensions mm Ø1 Ø L1 L L3 L E1 E E3 E Ø3 Ø ONDOR-V , M1 / ONDOR-V , M1 / ONDOR-V 1 11, M1 / ONDOR-V 5 15, M1 / ONDOR-V 1 15, M1 / ONDOR-V , M1 / ONDOR-V 5 19,1 553 / x 1. x 15 1 L Ø E3 L Ø E3 W1 R1 W1 E R1 E L L1 E1 L3 W L1 L E1 L3 W Ø1 Ø1 E R Ø ,5 3 Patte de Support fixation 16 feet x 16 1x Y 371 en option Y 371 (option) E R 1 16 Ø3 9,5 39 Support feet 16 x Patte de fixation 16 x 1 Y 371 Y 371 en option (option) 3 L Ø E3 L W Ø E3 3/8 NPTF W1 R1 E L3 W1 R1 E L1 L E1 L3 W L1 E1 Ø1 Ø1 Ø3 E R E R 9,5 3 Ø 1 16 Ø3 Patte de Support fixation 16 feet x 16 1x Y 371 en option Y 371 (option)
10 3.1 Refrigeration & limate omponents Solutions TY-EN 3.1- / -18 ONDOR-V (vertical) Volume V L Maximal working pressure PS bar Heat exchanger maximal working pressure PS Ech. bar Maximal working temperature TS maxi Minimal working temperature TS mini Working temperature ONDOR-V 1, / I ONDOR-V 15 3, / I ONDOR-V 3, / I ONDOR-V 5 7, / II ONDOR-V 1 8, / II ONDOR-V 1 3, / I ONDOR-V 5 15, / II lassification by volume, according to PED 1/68/EU (refer to chapter ). TS BT E ategory n Example of selection of a ONDOR water cooled condenser The sizing of a product implies for the buyer to take into account the conditions under which the product will be used (temperature - pressure refrigerant oil external environment). The values of the selection tables proposed in the catalogue match accurate test conditions. Installation operating with RA under the following conditions : Qk x = 1 kw Tk = Tl1 = > Δt1 = - = K Maximum water flow = 5 l/h Normal city water Which water cooled condenser ONDOR to choose? 1 Make corrections according to the water and the refrigerantes: orrection according to fouling factor Fe (refer to page 3.11) - 1- orrection according to refrigerant Fr (refer to page 3.11) Result: Qk = Qk x x Fe x Fr =1 kw Report the capacity to the quick selection table, page 3.11, and take note of possible condensers. Result: ONDOR-V 5, ONDOR-V 1, ONDOR-V 1, ONDOR-V 5 3 Search on the condenser feature curves, pages 3-6 to 3-9, the most suitable condenser. Result: - ONDOR V-5 works with Δt1 of 5K (page 3-13) (does not match because Δt1 > K). - ONDOR V-1 matches perfectly (page 3-1). - ONDOR V-1 works with a water flow of 7 l/h (page 3-1) (does not match because water flow > 5 l/h) - ONDOR V-5 is too powerful because Δt1 < K (page 3-15). Select the ONDOR V-1 model and determine on the curves the water Δt and the water pressure drop (page 3-1). Result: Δt water = 16,5K Δp water =,5 bar hapter «Abbreviations and units» (refer to chapter 113).
11 Refrigeration & limate omponents Solutions 3.11 TY-EN 3.1- / -18 ONDOR-V (vertical) According to the type of water available, the condensation capacity (Qkx) of the installation should be corrected in accordance to the fouling factor by the formula: Qk = Qkx x Fe Water type Fouling factor m.k / W orrection factor Fe Normal city water , Treated tower water , Untreated tower water ,19 River water ,19 Glycol water below % ,19 Glycol water below 7 % ,56 According to the type of refrigerant used, the condensation capacity (Qkx) of the installation should be corrected in accordance to the following Fr factor by the formula: Qk = Qkx x Fr Refrigerant orrection factor Fr RA / R57 1, R / R1A / R7F,9 R13a / R7,85 n Quick Selection Table 15 apacity kw Water flow l/h
12 3.1 Refrigeration & limate omponents Solutions TY-EN 3.1- / -18 ONDOR-V (vertical) 3 ONDOR-V 1 Dt eau = 5K Dt eau = 3K,1,5 Dt1 = 5K,1 apacity kw Puissance (kw) 1,5 1 Dp eau Dt1 = K Dt1 = 15K Dt eau = 1K,1,8,6 Perte de cherge eau (bar) Water pressure drop bar, Dt1 = 1K,5, Débit eau (l.h-1) Water flow l/h ONDOR-V 15 Dt eau = 1K Dt eau = 5K,16 3,5,1 Dp eau apacity kw 3,5 1,5 Dt1 = 5K Dt eau = 3K Dt1 = K Dt1 = 15K Dt1 = 1K,1,1,8,6 Perte de charge eau (bar) Water pressure drop bar 1 Dt1 = 5K, Dt eau = 1K,5, Water Débit eau flow (l.h-1) l/h
13 Refrigeration & limate omponents Solutions 3.13 TY-EN 3.1- / -18 ONDOR-V (vertical) 6 ONDOR-V Dt eau = 15K Dt eau = 1K,18 Dp eau,16 5,1 apacity kw Puissance (kw) 3 Dt1 = 5K Dt eau = 5K Dt1 = K Dt eau = 3K Dt1 = 15K Dt1 = 1K,1,1,8,6 Perte de charge eau (bar) Water pressure drop bar 1 Dt eau = 1K, Dt1 = 5K, Water flow l/h 1 1 ONDOR-V 5 Dt eau = 15K Dt1 = 5K Dt1 = K,,35 apacity kw 8 6 Dt eau = 1K Dt1 = 15K Dt1 = 1K Dt eau = 5K,3,5,,15 Perte de charge eau (bar) Water pressure drop bar,1 Dt1 = 5K, Water flow l/h
14 3.1 Refrigeration & limate omponents Solutions TY-EN 3.1- / -18 ONDOR-V (vertical) ONDOR-V 1 Dp eau,6,5 18 Dt eau = K apacity kw Dt1 = 5K Dt1 = K Dt eau = 15K Dt1 = 15K Dt eau = 1K,,3, Perte de charge eau (bar) Water pressure drop bar 6 Dt1 = 1K Dt eau = 5K, Water flow l/h ONDOR-V 1 Dt eau = K Dp eau,6 1 Dt1 = 5K,5 apacity kw Puissance (kw) Dt eau = 15K Dt1 = K Dt eau = 1K Dt1 = 15K Dt1 = 1K,,3, Perte de charge eau (bar) Water pressure drop bar Dt eau = 5K Dt1 = 5K, Water flow l/h
15 Refrigeration & limate omponents Solutions 3.15 TY-EN 3.1- / -18 ONDOR-V (vertical) ONDOR-V 5 Dt eau = K Dt eau = 15K,5,5 Dt1 = 5K Dp eau, apacity kw Puissance (kw) Dt1 = K Dt eau = 1K Dt1 = 15K Dt1 = 1K Dt eau = 5K,35,3,5,,15 Perte de charge eau (bar) Water pressure drop bar 6,1 Dt1 = 5K, Water flow l/h
16 3.16 Refrigeration & limate omponents Solutions TY-EN 3.1- / -18 ONDOR-V (vertical) n Spare parts and options 1 3 ONDOR V (S) Y /, 3/8 1(E)-1(E)-5(S) Y /8, 7/8, 1 1/8 5(E)-1 (S)-1(S) Y / 5(E) Y / (E) = Inlet, (S) = Outlet Gasket for ROTALOK and valves ØA ØB ONDOR V ROTALOK, gasket included ØA outlet ODF connection ØB fixing UNF connector (S) Y 17 1/ 3/ (S) Y 171 3/8 3/ 5(E)-1(S)-1(S) Y 17 1/ 1 1(E)-1(E)-5(S) Y /8 1 1/ 1(E)-1(E)-5(S) Y 17 7/8 1 1/ 1(E)-1(E)-5(S) Y /8 1 1/ 5(E) Y /8 1 3/ (E) = Inlet, (S) = Outlet
17 Refrigeration & limate omponents Solutions 3.17 TY-EN 3.1- / -18 ONDOR-V (vertical) n Spare parts and options B A ONDOR V (S) Y / 3/ (S) Y /8 3/ 5(E)-1(S)-1(S) Y / 1 5(E)-1(S)-1(S) Y /8 1 1(E)-1(E)-5(S) Y /8 1 1/ 1(E)-1(E)-5(S) Y /8 1 1/ 1(E)-1(E)-5(S) Y /8 1 1/ 5(E) Y /8 1 3/ (E) = Inlet, (S) = Outlet ROTALOK valve with connection to solder, gasket included ØA outlet ODF valve ØB fixing UNF valve B A ONDOR V (S) Y / 3/ (S) Y /8 3/ 5(E)-1(S)-1(S) Y / 1 (E) = Inlet, (S) = Outlet ROTALOK valve with connection to screw, gasket included ØB fixing SAE valve ØB fixing UNF valve ONDOR V Description Y 371 Support feet n Weights and packaging With packaging Unit weight kg Without packaging Packaging number of pieces ONDOR-V 1,5, 1 ONDOR-V 15 5,65 5, 1 ONDOR-V 5,65 5, 1 ONDOR-V 5 11,1 1,8 1 With packaging Unit weight kg Without packaging Packaging number of pieces ONDOR-V 1 1,3 1, 1 ONDOR-V 1 7,65 7, 1 ONDOR-V 5 6,1 5,5 1
TURBOIL (welded) / TURBOIL-F (flanged)
Refrigeration & limate omponents Solutions 41.1 TY-EN 41.1-6 / 02-2018 TURBOI (welded) / TURBOI-F (flanged) n Applications Separation and recovery of the oil carried by the refrigerant in vapour phase
More informationVCYL. Liquid sight glasses 9.1 NEW. Refrigeration & Climate Components Solutions. Max WP 46 bar and multi-fluids (G1 or G2) n Applications
Refrigeration & limate omponents Solutions 9.1 n Applications Immediate and direct monitoring of flow, condition or moisture content of the refrigerant in its liquid or diphasic phase in refrigerating
More informationRCY. Filter drier receiver units 4.1. Refrigeration & Climate Components Solutions. n Applications
Refrigeration & limate omponents Solutions 4.1 n Applications Refrigerant filtering and drying, and acid neutralization for refrigerating and air conditioning installation liquid lines. The filter driers
More informationDDNCY (Temporary use)
Refrigeration & limate omponents Solutions 3.1 leaning bi-directional flow and TY-EN 3.1-5 / 02-2018 DDNY (Temporary use) n Applications leaning and decontamination of refrigerant circuits in refrigerating
More information64 bar. DCY-P6 / 64 bar (928 psig) Anti-acid filter driers 1.9. subcritical. Refrigeration & Climate Components Solutions.
1.9 DY-P6 / 64 bar (928 psig) n Applications Filtering and drying of refrigerants and acid neutralization for liquid lines of refrigerating and air conditioning installations, running with high working
More informationTube-in-tube heat exchanger Type HE
Data sheet Tube-in-tube heat exchanger Type HE Tube-in-tube heat exchanger type HE is used primarily for heat transfer between the liquid and suction lines of the refrigeration plant. The purpose is to
More informationSOLENOID VALVES FOR REFRIGERATING SYSTEMS
SOLENOID VALVES FOR REFRIGERATING SYSTEMS APPLICATIONS The solenoid valves, shown in this chapter, are classified Pressure accessories in the sense of the Pressure Equipment Directive 97/23/EC, Article
More informationTube-in-tube heat exchanger Type HE
MAKING MODERN LIVING POSSIBLE Data sheet Tube-in-tube heat exchanger Type HE Tube-in-tube heat exchanger type HE is used primarily for heat transfer between the liquid and suction lines of the refrigeration
More informationHANDBOOK REFRIGERATING SYSTEM PROTECTORS. Ed REFRIGERATING SYSTEM PROTECTORS DP-ED 01/ ENG 1
HANDBOOK Ed. 2017 DP-ED 01/2017 - ENG 1 CHAPTER 14 INSPECTIONABLE STRAINERS For refrigeration plants that use the R744 refrigerant APPLICATIONS Castel has developed the inspectional strainers illustrated
More informationGeneral information on refrigerant controllers
General information on refrigerant controllers Condensing pressure controller The condensing or condenser pressure controller is a back pressure controller and its task is to maintain the condensing pressure
More informationCHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw
TECHNICAL INSTRUCTIONS CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw CHG 1 CHG 1 8. kw. kw.7 kw 1. kw April 7 19 - GB - 2 MARKING This product marked conforms to the essential
More informationPHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE
TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE
More informationPHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW
TECHNICAL INSTRUCTIONS PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER to KW PHRT PHRT PHRT PHRT For terminal units and boiler overhaul applications Heating Cooling PHRT.00 kw -. kw PHRT.0 kw /.0 kw
More informationOIL SEPARATORS APPLICATIONS
OIL SEPARATORS APPLICATIONS The oil separators, shown in this chapter, are classified Pressure vessels in the sense of the Pressure Equipment Directive 97/23/EC, Article 1, Section 2.1.1 and are subject
More informationIN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System
HEATING System fan (from model 25) and a MBE electric heater installed on the discharge side of the fan. + MBE ELECTRIC HEATER MBE heater type - Insulated element rods. - Automatic overheat thermostat
More informationTHERMAL SOLUTIONS COAXIAL HEAT EXCHANGERS WKE, WKC
THERMAL SOLUTIONS COAXIAL HEAT EXCHANGERS WKE, WKC COAXIAL HEAT EXCHANGERS WKE, WKC APPLICATIONS Wieland coaxial heat exchangers are used as evaporators (WKE) or as condensers (WKC). They consist of one
More informationELIMINATOR Hermetic filter drier for CO₂ DMSC for Sub-critical and DMT for Trans-critical application
Data sheet ELIMINATOR Hermetic filter drier for CO₂ DMSC for Sub-critical and DMT for Trans-critical application The filter drier is a vital element of the system s reliability as well as its lifespan.
More informationMechanical Systems Mechanical Systems
VING IMPRO ALLY NATUR Mechanical Systems 2017 Mechanical Systems E RMANC PERFO Content Rack Units Racks Units Opti OL Indoor Mini Compact OLtec EVO Maxi Compact Flexi Optivell Innovell Econvell Maxivell
More informationPWM expansion valves 2028
PWM expansion valves 2028 Application Solenoid expansion valve Castel type 2028 regulates the refrigerant flow into the evaporator by modulating the opening time phase of the plug and so permitting a wide
More informationkw COOLING kw HEATING
Heat pump water/water liquid chillers for indoor installation. Inversion on hydraulic circuit. 394 1505 kw COOLING 477 1976 kw HEATING technicalcatalogue T_FRGSCRWP_0913_GB INDEX GENERAL CHARACTERISTICS...
More informationHANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1
HANDBOOK Ed. 2017 RP-ED 01/2017 - ENG 1 DIRECTIVE 2014/68/EU ISSUED OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 MAY 2014 ON PRESSURE EQUIPMENT Directive 2014/68/EU (PED Recast) applies to the design,
More informationWATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ
WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationBrazed heat exchangers
HYGIENIC EQUIPMENT FOR FOOD & LIFE SCIENCES Brazed heat exchangers A product catalogue for refrigeration Refrigeration applications The brazed plate heat exchanger (BHE) is a well-established component
More informationAquaflair TRAC-TRAF-TRAH
Aquaflair TRAC-TRAF-TRAH 110 400 kw Air-cooled chillers, free-cooling chillers and heat pumps for mission critical applications Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors
More informationDYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers
High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER
More informationWater-Cooled Dual Compressor Screw Chiller
Installation Manual IM 692-1 Group: Chiller Part Number: 629955 Effective: May 1997 Supersedes: IM663-1 IM683 IM692 Water-Cooled Dual Compressor Screw Chiller Installation Manual PFS 155C through PFS 210C,
More informationAIR COOLED CONDENSING UNITS
AIR COOLED CONDENSING UNITS 50 Hz // ECOLITE ADVANCED SERIES BITZER ECOLITE air-cooled condensing units The new ECOLITE air-cooled condensing units for coercial refrigeration perfectly complement BITZER
More informationFilter Driers with Replaceable Core
STANDARD Filter Driers with Replaceable Core The filter driers with replaceable core (HTG series) are used in liquid line and suction line of refrigerating, freezing and air conditioning system. The filter
More informationLiquid Distributor Type RD
MAKING MODERN LIVING POSSIBLE Data sheet Liquid Distributor Type RD The RD refrigerant distributors distribute liquid refrigerants from the thermostatic expansion valve to individual sections of the evaporator.
More informationCMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL
CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years
More informationDYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers
High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER
More informationSB Series Brazed Plate Heat Exchanger Installation Manual
SB Series Brazed Plate Heat Exchanger Installation Manual HOT COLD Exploded view of Schmidt SB Brazed Plate Heat Exchanger. WARNING Before proceeding with installation and operation read entire manual
More informationHERZ Regulating valve 4002
HERZ Regulating valve 4002 Data sheet 4002, Issue 0214 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 42 1 4002 62 1 4002 43 1 4002 63 1 4002 44 1 4002 64 1 4002 45 1 4002 65 1 4002 46 1 4002 66 DN
More informationStandard Product QUICK SELECTION AIR CONDITIONING COMMERCIAL REFRIGERATION HEAT PUMP
Standard Product QUICK SELECTION AIR CONDITIONING COMMERCIAL REFRIGERATION HEAT PUMP Strive for perfection, Pursuit of excellence Sanhua is a leading HVAC&R manufacturer of controls and components with
More informationMAKING MODERN LIVING POSSIBLE. Thermostatic expansion valves, type TR 6 REFRIGERATION & AIR CONDITIONING DIVISION.
MAKING MODERN LIVING POSSIBLE Thermostatic expansion valves, type REFRIGERATION & AIR CONDITIONING DIVISION Technical leaflet Technical leaflet Thermostatic expansion valves, type Contents Page Introduction........................................................................................3
More informationMAC N-407 Air-Cooled Chiller
MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=
More informationORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.
ORTEC Compressed Air, Gas & Fluid Technologies t a l r o n m e n i l y E n v F r i e n d t r a n l y R e i g e f r INDUSTRIAL FLUID CHILLERS FC SERIES (0-00 TONS) Application Flexibility Nortec Industrial
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -
More informationCompressors, Chillers & Condensers
Totaline s water-cooled condensers are designed for a wide range of applications and are available in many models ranging from 5 to 400 nominal tons. Small and large condensers are available for fresh
More informationSyScroll Air EVO NEW
Chiller Close Control Water terminals SyScroll - Air EVO NEW Air Cooled Inverter Driven Water Heat Pump Engineering Data Manual.0 to.0 kw.0 to 34.0 kw SyScroll - Air EVO 3 Key points Wide load variation
More informationSyScroll 40 to 75 Air NEW
Chiller Close Control Water terminals SyScroll 40 to 75 Air NEW Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual 40.0 to 76.0 kw 40.0 to 77.0 kw SyScroll 40-75 Air 3 Key points
More informationFX5 Series Explosion-Proof Electric Air Heaters
FX5 Series Explosion-Proof Electric Air Heaters Ruffneck FX5 heaters are C UL US certified for use in hazardous locations. They are designed for the harshest environments such as: dry indoor industrial
More informationSingle pressure controls for Refrigeration, Air-conditioning and Heatpump applications
Series P77 Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications Product bulletin These pressure controls are designed for use in a variety of applications involving refrigeration
More informationRefrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW
Refrigerant R407C CW-AR Water Source Heat Pumps - Vertical Mounting Version Models 07 to 12 2.4 to 3.1kW 1.9 to 2.7kW Some advantages... RAL 9010 painted cabinet 3-fan speeds G2 filter is supplied as
More informationCHECK VALVES INSTALLATION
CHECK VALVES 35 CHECK VALVES APPLICATIONS The check valves illustrated herein are designed for use with refrigerant fluids CFC, HCFC and HFC. Castel check valves can be used on any section of a refrigerating
More informationAVAILABLE MODELS, NOMINAL CAPACITIES TABLE 1 and SOUND PRESSURE LEVELS. Optional acoustic component enclosure and two speed fans
YAES AIR COOLED SCREW CHILLER R407C REFRIGERANT COOLING CAPACITIES 369 kw to 613 kw The YAES (QPak) range of chillers are designed for water or water-glycol cooling. There are two product families, standard
More informationGLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning
: Packaged air cooled liquid chillers with free-cooling system for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 314 1343 Free-Cooling Capacity: 308 938 GLYCOL
More informationResearch Design Quality Value Service Experience
INDEX ACCUMULATORS...27 ACCUMULATOR - DRIERS...27 CAPILLARY ASSEMBLIES Strainer...30 Strainer-Drier...29 CHILLERS Heat Pump (For Capillary Systems)...22 Water (For Expansion Valves)...22 CONDENSERS (WATER
More informationHead Pressure Control Valves
Head ontrol s High and Low mbient Stability The design of air conditioning systems utilizing air cooled condensing units involves two main problems that must be solved if the system is to operate reliably
More informationMULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw
Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01
More informationECOCIAT. Domestic hot water heat recovery unit. Use. Range
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY FRIENDLY HFC R410A PROTECTION
More informationHERZ Differential Pressure Control Valve 4002
HERZ Differential Pressure Control Valve 4002 Data sheet 4002, Issue 0118 Dimensions in mm B1 B2 1 4002 41 1 4002 61 1 4002 71 1 4002 42 1 4002 62 1 4002 72 1 4002 43 1 4002 63 1 4002 73 1 4002 44 1 4002
More informationCMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N
E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,
More informationDanfoss Scroll for Refrigeration MLM / MLZ
s Danfoss Scroll for Refrigeration MLM / MLZ 50-60 Hz - R404A - R507 - R134a - R22 - R407A - R407F http://danfoss.us.com/ Contents Features... 6 Scroll compression principle... 7 The scroll compression
More informationRefrigerated Air Dryer
Refrigerated ir ryer Series For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and
More informationPlate Coil Heat Exchangers
Plate Coil Heat Exchangers UK Exchangers Ltd Unit 55 Stilebrook Road, Olney, Buckinghamshire, MK46 5EA, United Kingdom Tel: 0044 (0)1234 244320 Email: sales@ukeltd.com Web: www.uk-exchangers.com Plate
More informationENVIRONMENTAL CLIMATE CONTROL EQUIPMENT & SOLUTIONS AQUACOOL. Water-to-water heat pump with passive energy recovery.
ENVIRONMENTAL CLIMATE CONTROL EQUIPMENT & SOLUTIONS AQUACOOL Water-to-water heat pump with passive energy recovery www.ett.fr ENERGIE TRANSFERT THERMIQUE C O N T E N T S General description... 3 Operating
More informationv SELECTION GUIDELINES
v 2.2-01-2016 SELECTION GUIDELINES 1. SYSTEM PRESENTATION... 3 2. INSTALLATION SIZING... 6 3. SPECIFICATIONS... 11 4. DHW DIAGRAMS... 12 5. HEATING DIAGRAMS... 15 6. COOLING DIAGRAMS... 17 7. PRESSURE
More informationFlexible. Upgrade and service with ease Extend lifetime with modular design. Thermostatic expansion valves Type TE5-55
MAKING MODERN LIVING POSSIBLE Upgrade and service with ease Extend lifetime with modular design Thermostatic expansion valves Type TE5-55 Flexible Upgrade with backward compatible valve technology. Mix
More informationpyxis pyxisa NEW rcgroupairconditioning
Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 119,0 808,0 PLTE C rcgroupairconditioning
More informationPartial Load Performance Of Refrigeration System
Chapter 11 Partial Load Performance Of Refrigeration System Copy Right By: Thomas T.S. Wan 温到祥著 Sept. 3, 2008 All rights reserved Hot Gas Bypass & Liquid Injection: When the compressor is under surge condition,
More informationService Parts for RMR Wall-Mount Enclosures
Door Kits for RMR Wall-Mount Enclosures Replacement doors for RMR Wall-Mount Enclosures are removable and can be easily replaced if a door is damaged. Order latch separately. Several options are available:
More informationenvironmental climate control equipment & solutions AQUACOOL Water-to-water heat pump with passive energy recovery
environmental climate control equipment & solutions AQUACOOL Water-to-water heat pump with passive energy recovery made in France www.ett.fr energie transfert thermique c o n t e n t s General description...
More informationEQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM
TECHNICAL CATALOGUE EQEF Water Chillers with Free Cooling System Models:60.1 60.2 70.1 70.2 90.1 90.2 120.1 120.2 135.1 150.1 190.2 200.1 200.2 240.2 270.2 300.2 Cooling capacities: 69,7 to 331 KW 02.16
More informationLSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES
LS ir cooled water chillers with axial fans + LS The LS water chiller range has been designed for small and medium residential and commercial applications. They are suitable for generating chilled water
More informationTechnical Development Program
Technical Development Program COMMERCIAL HVAC CHILLER EQUIPMENT Water-Cooled Chillers PRESENTED BY: Omar Rojas Sales Engineer Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7
More informationTechnical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz
EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the
More informationPYXIS U PYXIS U. rcgroupairconditioning
Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44 284 rcgroupairconditioning MIN FETURES
More informationRefrigerated Air Dryer
T.S30-8 Refrigerated ir ryer Series IF/IU ir flow capacity Power consumption Refrigerant Increased up to the max. 40% ecreased up to the max. 40% F34a oefficient of destruction for ozone is zero. Improved
More informationRD refrigerant distributors, for thermostatic expansion valves REFRIGERATION AND AIR CONDITIONING. Technical leaflet
RD refrigerant distributors, for thermostatic expansion valves REFRIGERATION AND AIR CONDITIONING Technical leaflet Introduction RD refrigerant distributors distribute liquid refrigerants from the thermostatic
More informationpyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning
Industrial PYXIS CL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with scroll compressor and microchannel condensing coils Cooling Capacity: 108 876
More informationcondenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications
Outdoor condensing unit for direct expansion applications Variable speed propeller fan Cooling ENVIRONMENTALLY HFC R40A PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling capacity: 5. to 8.6 kw Use The CL
More informationBRAZED PLATE HEAT EXCHANGERS MOUNTING AND OPERATION MANUAL
BRAZED PLATE HEAT EXCHANGERS MOUNTING AND OPERATION MANUAL 1 CONTENTS Mounting and Operation Manual... 3 General information...4 Safety Instructions...4 Installing and Mounting...5 Connections...6 Installation
More informationCubic unit cooler. MUC/LUC commercial range
F W Glycol ubic unit cooler MU/LU commercial range eatcraft reserves itself the right to make changes at any time without preliminary notice - Photos non-contractual The MU-LU range meets the requirements
More informationHIWARM kw. Air-water system with external and internal BLDC unit. Total heat recovery multi-purpose units HIWARM PLUS
Total heat recovery multi-purpose units HIWARM Air-water system with external and internal BLDC unit HIWARM - kw The perfect combination between multi-purpose, inverter technology and style Multi-purpose
More informationRefrigerated Air Dryer
Refrigerated ir ryer E/F Series For use in Europe, sia and Oceania Standard/ E Series H HW Power supply voltage: Single-phase 230 V (50Hz) 3E 4E 6E 8E 11E 15E1 22E 37E 55E 75E ir flow capacity (m3/h [NR])
More informationSLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual
u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications
More informationkw. technicalcatalogue
Packaged air cooled liquid chillers in A class energy efficiency for outdoor installation equipped with scroll compressor and microchannel condensing coils 108 876 kw technicalcatalogue T_PYXCLA_0413_GB
More informationCONDENCIAT CD. Condensing units. Quiet operation Low speed fans All year round operation USE. Cooling capacity : 25 to 165 kw.
Quiet operation Low speed fans All year round operation Cooling capacity : 25 to 165 kw Cooling only USE The offers a solution to both heating and cooling applications encountered in the public, tertiary
More informationYCAL-SB Millennium AIR COOLED LIQUID CHILLER R407C REFRIGERANT. COOLING CAPACITIES 141 kw to 360 kw
YCAL-SB Millennium AIR COOLED LIQUID CHILLER R407C REFRIGERANT COOLING CAPACITIES 141 kw to 360 kw YORK YCAL-SB Millennium air cooled scroll liquid chillers provide chilled liquid for all air conditioning
More information30GN FLOTRONIC II AIR-COOLED CHILLERS
30GN-19SB 30GN040-110 FLOTRONIC II AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GN-19SB Supersedes 30GN-6SB, 30GN-7SB, 30GN-8SB, Printed
More informationOperating instructions for semi-hermetic motorcompressors
Operating instructions Page 1 Operating instructions Type: HG 4/310-8/4 S HG 4/385-8/4 S HG 4/465-8/4 S HG 4/555-8/4 Page 2 Page 3 Contents Page 1. Safety instructions...4 2. Main and functional parts...4
More informationAIC Brazed Plate Heat Exchanger Operating and Instruction Manual
AIC Brazed Plate Heat Exchanger Operating and Instruction Manual Advanced Industrial Components Page 1 of 8 Customer Service Call: 1-888-738-1350 1.0 Installation 1.1 Mounting/support unit: a) On a shelf
More informationTITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F
Temperature Control Units Water & Oil - F Portable Chillers Air & Water-Cooled - 7 F Central Chillers Air & Water-Cooled Packages & Modules - 7 F Pump Tank Stations Chilled or Tower Water - gallons Cooling
More informationDuct heaters for ATEX/IECEx hazardous areas or in non-atex version
for ATEX/IECEx hazardous areas or in non-atex version * Non contractual picture Warning It is imperative to read these instructions carefully before installing or maintaining the equipment. MI200EN 09/2017
More informationAlfaNova the first fusion-bonded plate heat exchanger. A product brochure for AlfaNova within Industrial Refrigeration
AlfaNova the first fusion-bonded plate heat exchanger A product brochure for AlfaNova within Industrial Refrigeration AlfaNova A new concept for plate heat exchangers Out of the extreme heat in our furnaces
More informationFRIGO SCREW CLA PLUS Packaged water cooled liquid chillers in A+ class energy efficiency for indoor installation. Cooling Capacity: kw
Packaged water cooled liquid chillers in + class energy efficiency for indoor installation. Cooling Capacity: 625 1179 kw Screw compressors Shell and tube heat exchangers Double refrigerant circuit EER
More information100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION
100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest
More informationINFRARED THERMOMETER. Thermometer
INFRARED THERMOMETER Usefull infrared thermometer for temperature measurements between -20 C und 420 C. A laserbeam makes it easier to meassure the temperature of the object. A big LC screen displays the
More information2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating
2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER AIR-TO-WATER HEAT PUMP cooling - heating MINI CHILLER Highly efficient heat pump for summer and winter air conditioning. Ideal for residential and commercial
More informationUNICO TURBO FL FREE UNICO TURBO FL FREE HIGHEFFICIENCY INVERTER ACLASS FREECOOLING LOWNOISE. rcgroupairconditioning
: Packaged air cooled liquid chillers with free-cooling system in class energy efficiency for outdoor installation, equipped with oil-free centrifugal compressors with magnetic levitation bearings, flooded
More informationThermostatic Expansion Valves Type TR 6
MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic Expansion Valves Introduction The series is a hermetic tight design, designed and developed with features especially for use in applications such as:
More informationBRAZED PLATE HEAT EXCHANGERS
BRAZED PLATE HEAT EXCHANGERS MOUNTING AND OPERATION MANUAL Contents Mounting and operation manual of brazed plate heat exchangers... 2 1. General information...3 2. Safety instructions...3 3. Installing
More informationDEHYDRATORS AND FILTERS
DEHYDRATORS AND FILTERS 91 DEHYDRATION OF REFRIGERANTS Among contaminating agents causing serious damages to refrigerating systems, moisture plays a major role. Its presence, even possible in the refrigerating
More informationEpsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points
Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique
More information30GT FLOTRONIC AIR-COOLED CHILLERS
30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed
More informationQuality Heat Exchangers
Quality Heat Exchangers Brazed Plate Heat Exchangers Universal solutions for industrial and domestic applications With partnership into the future FUNKE is a leader in the development and production of
More informationUltimate energy saving technology
Ultimate energy saving technology CWT Chiller Series CWt purestream series water chillers The new CWT Purestream chiller range is specifically designed to meet the stringent cooling requirements of today
More information