RCY. Filter drier receiver units 4.1. Refrigeration & Climate Components Solutions. n Applications
|
|
- Abel Walker
- 5 years ago
- Views:
Transcription
1 Refrigeration & limate omponents Solutions 4.1 n Applications Refrigerant filtering and drying, and acid neutralization for refrigerating and air conditioning installation liquid lines. The filter driers receivers provide a permanent reserve of dehydrated and filtered refrigerant, for a better supply of the expansion valve, whatever the operating conditions. The filter drier receivers are particularly suited to low capacity installations that operate with a thermostatic pressure relief valve and that are equipped with an air-cooled condenser or a plate condenser. receivers fit perfectly within the heat pump systems. ustomized product Standard product n Functional features Products are compatible with Fs, HFs, HFs, O 2 s, as well as with their associated oils and additives. Products are designed for use of non-hazardous refrigerants from group 2 of PED 97/23/E. To use components with fluids of the hydrocarbon group 1 Propane R290, Butane R600, Isobutane R600a, Propylene R1270 with HFOs and transcritical O 2 and for a RANKINE organic cycle application, contact technical department. Product classification in E categories is performed using the PED 97/23/E table, corresponding to a volume-based selection. Hermetically sealed outer steel enclosure with paint to ensure a high resistance to corrosion. Filtering at outlet preventing propagation within the circuit of particles bigger than 25 microns, with a very low pressure drop. No desorption, even at high s. Possible customization on request: Drying capacity Receiver volume Specific unions (O-RING, ORFS, etc.) Adding of an indicator with or without hygroscopic paper on the receiver part Aluminium casings and connections (weight optimisation) Stainless steel casings and connections (resistance to corrosion and at low s) onnections to braze, 100 % copper Model «Bi-flow». n advantages Maximal pressure: 46 bar. ompared to an assembly with two separated components (filter drier + receiver) è Space gain on the installation è Optimisation of assembly time è 2 connections to be screwed or brased instead of 4 ; therefore, reducing the risk of leakage Great drying and acid neutralization capacity at all s, thanks to a rigorous selection and a judicious mix of the chemical agents present in the filter driers (activated alumina in order to neutralise the acids and molecular sieves to adsorb moisture); the volume of free-grains drying agents used in a filter drier is greater than that present in an equivalent model with a solid core. Initial drying capacity guaranteed by a 200 oven drying and airtight sealing. Drying ensured for the subcritical O 2 applications at low s. A dispenser located at the intake ensures optimal distribution and permanent treatment of the whole refrigerant, inside the filter drier receiver. The copper-plated steel connections facilitate the brazing and allow using brasing alloys with a low silver percentage. GOST certified products.
2 4.2 Refrigeration & limate omponents Solutions n Warning Before selecting or installing any component, please refer to the chapter 0 - WARNING. n General assembly precautions The installation of a component in a refrigeration system by a skilled professional, requires some precautions: Some are specific to each component, and in this case, they are specified in the REOMMENDATIONS SPEIFI part defined hereafter ; Other are general to all components, they are presented in the chapter 115 GENERA ASSEMBY PREAUTIONS. The recoendations relating to the components for the subcritical O 2 applications are also developed in chapter 115 GENERA ASSEMBY PREAUTIONS. n Recoendations specific to the filter-drier receivers receivers are to be mounted on the liquid line between the condenser and the expansion element. The refrigerant flow direction is indicated by an IN mark in the inlet shell of the filter drier and by an arrow on the filter drier tag. It must be necessarily respected. Mounting of filter drier receivers should always be performed vertically, refrigerant inlet up, for proper use of the receiver part. We recoend the use of a brasing at 10 % silver minimum for the brasing of the copper coated silver unions. Be careful to properly select the solenoid valves located downstream of the filter driers; their over-sizing could cause liquid haer phenomena hindering the filter driers mechanical behaviour; protection of regulation elements located upstream of the evaporator should be performed with FITRY dirt filters (refer to chapter 11); these liquid haer phenomena can originate from other sources, in longpiping installations. Never install the filter driers in an area of the circuit that can be isolated. Never trap the refrigerant in its liquid state (between a check valve and a solenoid valve, for instance). The filter driers must be changed : è after each intervention on the installation requiring the opening of the circuit è when the liquid indicator (VY or VYS) indicates an abnormal humidity content è when the pressure loss measured in the filter drier is too high è at least once a year as a measure of precaution A filter drier saturated in humidity no longer retains the water molecules which circulate then in the circuit ; these molecules in contact with other materials and with the POE oils which are very hydrophilic are liable to form acids which can be fatal for the installation ; therefore, it is very important to use filter driers containing activated alumina in order to neutralise as rapidly as possible the acids present in the circuit and not dewatering filters with only 100 % of a molecular screen. efficiency and refrigerant moisture content should be checked using VY or VYS liquid sight glasses (refer to chapters 9 or 10). Make sure that the piping can support without deformation the weight of the filter drier ; otherwise, provide for the attachment of the filter drier with a clamp on a stable part of the installation. Example of a selection of a for the drying part of the product : see example of a selection of a DY filter drier in chapter 1. For the liquid tank part of the product, use the usual methods for determining the coolant fluid storage volume by taking into account all the parameters related to the user s application.
3 Refrigeration & limate omponents Solutions 4.3 n Selection table onnections To screw SAE inch To solder ODF inch onnections To solder ODF R22 Refrigerating capacity kw R134a R404A R407 R507 R410A R407F R744 O 2 (4) Dehydratable refrigerant capacity kg of refrigerant R22 R407 R407F R134a R410A R404A R507 R744 O S 3/8-1/4 (3) 8,0 7,3 5,2 7,9 9,0 10,5 9,0 11,0 10,5 17,0 9,5 6,4 522 S 1/4 522 MMS 6 8,0 7,3 5,2 7,9 9,0 10,5 9,0 11,0 10,5 17,0 9,5 6,4 523 S 3/8 523 MMS 10 20,0 18,2 13,0 19,8 22,4 10,5 9,0 11,0 10,5 17,0 9,5 6,4 743 S 3/8 743 MMS 10 35,0 31,9 22,8 34,7 39,2 38,5 32,5 40,0 38,5 61,0 34,0 23,4 744 S 1/2 744 MMS 12 38,0 34,6 24,7 37,6 42,6 38,5 32,5 40,0 38,5 61,0 34,0 23,4 924 S 1/2 924 MMS 12 40,0 36,4 26,0 39,6 44,8 50,0 42,5 52,0 50,0 79,0 44,0 30,3 925 S/MMS 5/ ,0 38,2 27,3 41,6 47,0 50,0 42,5 52,0 50,0 79,0 44,0 30,3 Refrigerating capacities according to Standard ARI for To = 15, Tk = 30 and p = 0.07 bar. If different conditions, refer to correction factors in chapter 112. Dehydratable refrigerant capacity according to Standard ARI (3) Inlet 3/8 - Outlet 1/4 (4) Refrigerating capacities Qn for Tk = 10 and To = 40 For Tk = 0 Qo = Qn + 12 %, For Tk = 20 Qo = Qn 10 %, For To = 30 Qo = Qn 2 %, For To = 20 Qo = Qn 6 % Nota: the diameter of connections must not be inferior to the diameter of the main pipe.
4 4.4 Refrigeration & limate omponents Solutions n Technical features onnection types Filtering surface cm S , S 522 MMS , S 523 MMS , S 743 MMS , S 744 MMS , S 924 MMS , S/MMS , hapter «onnection features and drawings» (refer to chapter 114). Volume of desiccation products cm 3 Receiver volume Ø1 Dimensions Ø2 Ø2 Ø1
5 Refrigeration & limate omponents Solutions 4.5 n Technical features Volume S 0, Art S 522 MMS 0, Art S 523 MMS 0, Art S 743 MMS 0, Art S 744 MMS 0, Art S 924 MMS 1, I 925 S/MMS 2, I The pressure is limited to the PS BT value when is lower than or equal to TS BT value. lassification by volume, according to PED 97/23/E (refer to hapter 0). V Maximal pressure PS bar Working pressure PS BT bar Maximal TS maxi Minimal TS mini Working TS BT E ategory n Weights and packaging With packaging Unit weight kg Without packaging Packaging number of pieces S 0,38 0, S & MMS 0,48 0, S & MMS 0,48 0, S & MMS 1,03 1, S & MMS 1,03 1, S & MMS 1,73 1, S/MMS 2,43 2,35 1
64 bar. DCY-P6 / 64 bar (928 psig) Anti-acid filter driers 1.9. subcritical. Refrigeration & Climate Components Solutions.
1.9 DY-P6 / 64 bar (928 psig) n Applications Filtering and drying of refrigerants and acid neutralization for liquid lines of refrigerating and air conditioning installations, running with high working
More informationDDNCY (Temporary use)
Refrigeration & limate omponents Solutions 3.1 leaning bi-directional flow and TY-EN 3.1-5 / 02-2018 DDNY (Temporary use) n Applications leaning and decontamination of refrigerant circuits in refrigerating
More informationVCYL. Liquid sight glasses 9.1 NEW. Refrigeration & Climate Components Solutions. Max WP 46 bar and multi-fluids (G1 or G2) n Applications
Refrigeration & limate omponents Solutions 9.1 n Applications Immediate and direct monitoring of flow, condition or moisture content of the refrigerant in its liquid or diphasic phase in refrigerating
More informationTURBOIL (welded) / TURBOIL-F (flanged)
Refrigeration & limate omponents Solutions 41.1 TY-EN 41.1-6 / 02-2018 TURBOI (welded) / TURBOI-F (flanged) n Applications Separation and recovery of the oil carried by the refrigerant in vapour phase
More informationCONDOR-H (horizontal) / CONDOR-V (vertical)
Refrigeration & limate omponents Solutions 3.1 TY-EN 3.1- / -18 ONDOR-H (horizontal) / ONDOR-V (vertical) n Applications ensure cooling, condensation and storage of refrigerant in refrigerating and air
More informationDEHYDRATORS AND FILTERS
DEHYDRATORS AND FILTERS 91 DEHYDRATION OF REFRIGERANTS Among contaminating agents causing serious damages to refrigerating systems, moisture plays a major role. Its presence, even possible in the refrigerating
More informationDehydrators and Filters
Dehydrators and Filters DEHYDRATION OF REFRIGERANTS Among contaminating agents causing serious damages to refrigerating systems, moisture plays a major role. Its presence, even possible in the refrigerating
More informationSOLENOID VALVES FOR REFRIGERATING SYSTEMS
SOLENOID VALVES FOR REFRIGERATING SYSTEMS APPLICATIONS The solenoid valves, shown in this chapter, are classified Pressure accessories in the sense of the Pressure Equipment Directive 97/23/EC, Article
More informationELIMINATOR Hermetic filter drier for CO₂ DMSC for Sub-critical and DMT for Trans-critical application
Data sheet ELIMINATOR Hermetic filter drier for CO₂ DMSC for Sub-critical and DMT for Trans-critical application The filter drier is a vital element of the system s reliability as well as its lifespan.
More informationFilter Driers with Replaceable Core
STANDARD Filter Driers with Replaceable Core The filter driers with replaceable core (HTG series) are used in liquid line and suction line of refrigerating, freezing and air conditioning system. The filter
More informationOIL SEPARATORS APPLICATIONS
OIL SEPARATORS APPLICATIONS The oil separators, shown in this chapter, are classified Pressure vessels in the sense of the Pressure Equipment Directive 97/23/EC, Article 1, Section 2.1.1 and are subject
More informationAccumulators - Suction Line
ACCUMULATORS Accumulators - Suction Line kw Cap at Evap. Temp. -6 C Size Connection R22 R404A / R507C F0804 1/2" ODS Vertical 4.6 4.8 F0805 5/8" ODS Vertical 6.9 7.2 F0806 3/4" ODS Vertical 9.2 9.6 F0807
More informationRESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES
SECTION 23 23 00 REFRIGERANT PIPING AND SPECIALITIES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Refrigerant piping. 2. Unions, flanges, and couplings. 3. Pipe hangers and supports. 4. Refrigerant
More informationHANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1
HANDBOOK Ed. 2017 RP-ED 01/2017 - ENG 1 DIRECTIVE 2014/68/EU ISSUED OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 MAY 2014 ON PRESSURE EQUIPMENT Directive 2014/68/EU (PED Recast) applies to the design,
More informationFSW. Product guide. Driers and Sight Glasses CSECTION For more information visit
FSW Product guide CSECTION Driers and Sight Glasses For more information visit www.fsw.uk.com 47 Copper Spun Driers Suitable for HFC, CFC and HCFC. CODE MODEL SIZE CONNECTIONS C440 MSCD-5-3 5 Gram 3/16"
More informationSealed Type Liquid Line and Suction Line Specifications
CATALOG 0 Page,, 4a, 404A, 407C, 40A, 0, 07 Also Compatible with Refrigerants, 4,, 40A & B, 40A & B, 408A, 409A The universal acceptance of the Catch-All Filter-Drier is due to its unique molded porous
More informationRD refrigerant distributors, for thermostatic expansion valves REFRIGERATION AND AIR CONDITIONING. Technical leaflet
RD refrigerant distributors, for thermostatic expansion valves REFRIGERATION AND AIR CONDITIONING Technical leaflet Introduction RD refrigerant distributors distribute liquid refrigerants from the thermostatic
More informationThe Essentials Of Working With R-410A
The Essentials Of Working With R-410A By Norm Christopherson Several major manufacturers are producing comfort air conditioning equipment using refrigerant 410A. The trend towards the use of 410A continues
More informationLINE COMPONENTS VALVES
VALVES DANFOSS THERMOSTATIC EXPANSION VALVES - T2 T2 thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. The refrigerant superheat determines the amount. Large
More informationR-407A R-448A R-449A
GUIDELINES FOR THE UTILIZATION OF R-407A R-448A R-449A 2018 Tecumseh Products Company LLC. All rights reserved. Page 1 of 9 R-407A, R-448A, and R-449A are recognized as suitable alternative refrigerants
More informationLiquid Distributor Type RD
MAKING MODERN LIVING POSSIBLE Data sheet Liquid Distributor Type RD The RD refrigerant distributors distribute liquid refrigerants from the thermostatic expansion valve to individual sections of the evaporator.
More informationT2 thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. The refrigerant superheat determines the amount.
DANFOSS THERMOSTATIC EXPANSION - T2 T2 thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. The refrigerant superheat determines the amount. FEATURES Large temperature
More informationPublication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS
Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS Refrigerant R22 is widely used for residential and commercial air conditioning, as well as commercial refrigeration
More informationSTARBOX - CONDENSER UNITS
EN STARBOX - CONDENSER UNITS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Table of Contents 1. General Information 1 2. Handling and Storage.. 1 3. Installation. 1 4. Electrical Connections.. 4
More informationHANDBOOK REFRIGERATING SYSTEM PROTECTORS. Ed REFRIGERATING SYSTEM PROTECTORS DP-ED 01/ ENG 1
HANDBOOK Ed. 2017 DP-ED 01/2017 - ENG 1 CHAPTER 14 INSPECTIONABLE STRAINERS For refrigeration plants that use the R744 refrigerant APPLICATIONS Castel has developed the inspectional strainers illustrated
More informationREFRIGERATION PRODUCTS
SE REFRIGERATION PRODUCTS Smart Electric products offer reliable and longer lasting solutions for refrigeration. We know how important it is to keep systems clean and running at its full efficiency for
More informationDESIGN STANDARDS SECTION 15600
PART 1 - GENERAL 1.1 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.2 General requirements: A. Reciprocating
More informationcondenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications
Outdoor condensing unit for direct expansion applications Variable speed propeller fan Cooling ENVIRONMENTALLY HFC R40A PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling capacity: 5. to 8.6 kw Use The CL
More informationR E D I C O N T R O L S
R E D I C O N T R O L S File Literature Number 1144-01-1 Installation Operation & Maintenance Manual CONTINUOUS REFRIGERANT DEHYDRATOR Model: CD-120 For use with Refrigerants R-11, R-123, R-12, R-22, R-134a
More informationDESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6
DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6 1.1. REFERENCE STANDARDS 1.2. GENERAL 1.1.1. The units shall be listed by Electrical Testing Laboratories (ETL) and bear the ETL label. 1.1.2.
More informationDanfoss Inverter scroll compressor, VRJ
Application Guidelines Danfoss Inverter scroll compressor, VRJ For Residential Applications - R410A http://danfoss.us.com/ Contents Introduction...6 Scroll compressor components... 6 Compressor size...
More informationZero ODP and negligible GWP when using hydrocarbons. Zero. portfolio for hydrocarbons.
Danfoss components for hydrocarbon refrigeration Leapfrog Extensive to a portfolio long-term and solution expertise with for safe Danfoss and optimised wide product use of hydrocarbons portfolio for hydrocarbons
More informationSANHUA S OFFER FOR REFRIGERATION APPLICATIONS
SANHUA S OFFER FOR REFRIGERATION APPLICATIONS Strive for perfection, Pursuit of excellence Sanhua is a leading HVAC&R manufacturer of controls and components with a global footprint and 30 years of experience.
More informationREFRIGERANT PIPING SYSTEM
PART 1 GENERAL 1.01 DESCRIPTION A. The requirements of this section apply to the refrigerant piping system connecting refrigeration and HVAC equipment specified in other sections of these specifications.
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationTHERMAL SOLUTIONS COAXIAL HEAT EXCHANGERS WKE, WKC
THERMAL SOLUTIONS COAXIAL HEAT EXCHANGERS WKE, WKC COAXIAL HEAT EXCHANGERS WKE, WKC APPLICATIONS Wieland coaxial heat exchangers are used as evaporators (WKE) or as condensers (WKC). They consist of one
More informationDesiccants & Driers. By Norm Christopherson
Desiccants & Driers By Norm Christopherson Filter-driers play a pivotal role in the operation of hvac systems. At the heart of the drier is the desiccant held in the drier s cylindrical metal container.
More information12 In Row. Installation Manual. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.
MISSION CRITICAL Air Conditioning Systems 12 In Row Installation Manual ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 2 Table of Contents Table of Contents... 3 Site
More informationTube-in-tube heat exchanger Type HE
Data sheet Tube-in-tube heat exchanger Type HE Tube-in-tube heat exchanger type HE is used primarily for heat transfer between the liquid and suction lines of the refrigeration plant. The purpose is to
More informationSECTION (15530) - REFRIGERANT PIPING
PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Tubes. 2. Fittings. SECTION 23 23 00 (15530) - REFRIGERANT PIPING 3. Joining Materials. 4. Specialties. B. Related Sections: 1.02 REFERENCES 1. Section
More informationDescription Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)
INDEX UNIVERSAL ELECTRONIC CONTACTOR UPGRADE SURESWITCH 79 Description Model(s) Page(s) SureSwitch... 49P11-843... 79 CONTACTORS 80 82 Description Model(s) Page(s) 1 Pole... 94-388 Thru 94-395... 80 2
More informationAir Cross 21 Installation and User Manual
Air Cross 21 Installation and User Manual 1 Introduction AirCross BPHE is a stainless steel cross flow plate heat exchange which is vacuume brazed with pure copper or nickel based material as the brazing
More informationCONDENCIAT CD. Condensing units. Quiet operation Low speed fans All year round operation USE. Cooling capacity : 25 to 165 kw.
Quiet operation Low speed fans All year round operation Cooling capacity : 25 to 165 kw Cooling only USE The offers a solution to both heating and cooling applications encountered in the public, tertiary
More informationSECTION (15530) - REFRIGERANT PIPING
SECTION 23 23 00 (15530) - REFRIGERANT PIPING PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Tubes. 2. Fittings. 3. Joining Materials. 4. Specialties. B. Related Sections: 1. Section 07 92 00 (07920)
More informationCopeland Scroll Condensing Units for the Food Service Market
Copeland Scroll Condensing Units for the Food Service Market...with Best In Class Emerson System Protection Components Medium and Low Temperature Refrigeration Applications R-404A 1.5 to 10 Hp Reliable
More informationNew standard in compressed air treatment, providing Energy Savings up to 99%
PCM Series Specification for APAC Model Flow Capacity (Nm 3 /min) Pressure Dew Point ( ) Power Consumption (kw) Power Supply (V/Ph/Hz) Inlet/Outlet Connections Weight (kg) Dimensions (H x W x D mm) Refrigerants
More informationCHECK VALVES INSTALLATION
CHECK VALVES 35 CHECK VALVES APPLICATIONS The check valves illustrated herein are designed for use with refrigerant fluids CFC, HCFC and HFC. Castel check valves can be used on any section of a refrigerating
More informationTechnical Development Program
Technical Development Program COMMERCIAL HVAC CHILLER EQUIPMENT Water-Cooled Chillers PRESENTED BY: Omar Rojas Sales Engineer Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7
More informationCONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY
CONDENSING UNITS. AIR COOLED CONDENSER. CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY SERIES: DXCZ MODELS: 171, 201, 221, 251, 271, 351 371, 401, 451, 501, 701 and 721 COOLING CAPACITIES OF: 4,7
More informationInstallation, Start-Up and Service Instructions
38AH044-134 Air-Cooled Condensing Units 50/60 Hz Installation, Start-Up and Service Instructions CONTENTS Page SAFETY CONSIDERATIONS...................... 1 INSTALLATION................................
More informationCompact and silent Scroll compressors All-season operation
Compact and silent Scroll compressors All-season operation Cooling capacity: 40 to 161 kw 410a Cooling only Use The new generation of CONDENCIAT condensation units is the solution for all split-system
More informationRecommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS
COMMERCIAL REFRIGERATION RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS www.tecumseh.com Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) 1-HCFCs & HFCs Retrofit
More informationOwner s Manual Therma-Stor II Heat Recovery System
PO Box 8680 Madison, WI 53708 TS-138C Revised 8/08 Owner s Manual Therma-Stor II Heat Recovery System Installation, Operation & Service Instructions Read and Save These Instructions Table Of Contents 1.
More informationInstallation Instructions
Installation Instructions Part No. 30RA-900---057 and 30RA-900---060 30RAP010-150 Remote Cooler Mounting Accessory SAFETY CONSIDERATIONS Installation of this accessory can be hazardous due to system pressures,
More informationSeries 6, Vertical Floor-Mount Units
MISSION CRITICAL Air Conditioning Systems Series 6, Vertical Floor-Mount Units Installation Manual ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 2 Table of Contents
More informationPOWER PACKS FOR SUB-CRITICAL CASCADE R744 APPLICATIONS RECIPROCATING ACCESSIBLE-HERMETIC OCTAGON COMPRESSORS
OPERATING INSTRUCTIONS INSTALLATION COMMISSIONING OPERATING MAINTENANCE (must be given to the end user in order to complete the operating manual during the equipment service life) POWER PACKS FOR SUB-CRITICAL
More informationGeneral Service Bulletin
General Service Bulletin HCOM-SB-45B Library Service Literature Product Section Refrigeration Product Reciprocating & Scroll Hermetic Compressors Model Hermetic Compressors Literature Type General Service
More informationGeneral information on refrigerant controllers
General information on refrigerant controllers Condensing pressure controller The condensing or condenser pressure controller is a back pressure controller and its task is to maintain the condensing pressure
More informationECOCIAT. Domestic hot water heat recovery unit. Use. Range
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY FRIENDLY HFC R410A PROTECTION
More informationBrazed Plate Heat Exchanger Operations Manual
razed Plate Heat Exchanger Operations Manual razed Exchanger Operations Manual razed Heat Exchangers from Polaris deliver exceptional strength and performance in a compact package. These versatile units
More informationPHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE
TEcHnIcal InsTRucTIons PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE PHRIE 095 PHRIE 1 PHIE 095 PHIE 1 PHRIE 155 PHRIE 157 PHRIE 175 PHRIE 177 PHRIE 195 PHRIE 197 PHRIE 7 PHRIE
More informationv SELECTION GUIDELINES
v 2.2-01-2016 SELECTION GUIDELINES 1. SYSTEM PRESENTATION... 3 2. INSTALLATION SIZING... 6 3. SPECIFICATIONS... 11 4. DHW DIAGRAMS... 12 5. HEATING DIAGRAMS... 15 6. COOLING DIAGRAMS... 17 7. PRESSURE
More informationOACS Outdoor Air-Cooled Central Chillers
OACS Outdoor Air-Cooled Central Chillers Proudly Made In The USA since 1977 A Complete Central Chiller System Complete Central Chiller system with Integrated Reservoir and Pump all mounted on a single
More informationGENERAL INFORMATIONS
GENERAL INFORMATIONS Devices only operate in cooling mode. Enviromental-friendly R407c coolant is utilized in standard products. The system can be created with various coolants depending on the water temperature
More informationNational Maritime Center
National Maritime Center Providing Credentials to Mariners U.S.C.G. Merchant Marine Exam (Sample Examination) Page 1 of 26 Choose the best answer to the following Multiple Choice Questions. 1. If a condenser
More informationDownstream Equipment. Intelligent Air Technology
Downstream Equipment Intelligent Air Technology The Clean Air Solution The advanced range of CompAir inline equipment has been specially developed to meet the needs of modern manufacturing and processing
More informationReference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.
GUIDELINES FOR THE UTILIZATION OF R-404A R-452A Page 1 of 10 GUIDELINES FOR THE UTILIZATION OF R-404A AND R-452A For many years, R-404A has emerged as the industry's major choice as an alternative refrigerant
More informationCO2 TRANSCRITICAL BOOSTER SYSTEMS
CO2 TRANSCRITICAL BOOSTER SYSTEMS William Katz Sr. Technical Writer Hillphoenix 2016 Gees Mill Road Conyers, GA 30013 Tel: 678-613-9364 Email: william.katz@hillphoenix.com Refrigeration systems for supermarkets
More informationDue to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.
TECHNICAL DATA SHEET R434A () Features and uses of R-434A () is a non-flammable HFC mixture. ODP = 0, compatible with traditional mineral lubricants, alkyl benzene and also with synthetic POE, so there
More informationINSTALLATION, COMMISSIONING AND OPERATING MANUAL
INSTALLATION, COMMISSIONING AND OPERATING MANUAL 1 YTBV-D-CE42_0109 CONTENT Available models and capacities Supplier information Warranty Safety Emergency stops/ shutdowns About this manual Models Physical
More informationManeurop reciprocating compressors MT / MTZ
MAKING MODERN LIVING POSSIBLE Application guidelines Maneurop reciprocating compressors MT / MTZ 50-60 Hz - R22 - R417A - R407A/C/F - R134a - R404A / R507 www.danfoss.us Contents Maneurop reciprocating
More informationSECTION REFRIGERANT PIPING
SECTION 23783 REFRIGERANT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationDYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers
High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER
More informationEnergy Use in Refrigeration Systems
2012 Rocky Mountain ASHRAE Technical Conference Energy Use in Refrigeration Systems PRESENTED BY: Scott Martin, PE, LEED AP BD+C Objectives Understand mechanical refrigeration terms Describe how heat is
More information1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.
WYETH-AYERST CANADA INC. 1025, BOUL. MARCEL-LAURIN S T - L A U R E N T, Q U É B E C INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER MODEL P448800LT--55WC--22C66S Prepared par Claude Gadoury, P.
More informationInstructions for installation
Instructions for installation Read this notice carefully before installing, maintaining or repairing this appliance! The symbol indicates important information that you must take into account to avoid
More informationManeurop reciprocating compressors NTZ
Maneurop reciprocating compressors NTZ R404A - R507-60 Hz http://danfoss.us.com/ Content Maneurop reciprocating compressors...5 Features...5 Specifications...6 Technical specifications and nominal ratings...6
More informationTHERMOSTATIC EXPANSION VALVES
THERMOSTATIC EXPANSION VALVES SPORLAN THERMOSTATIC EXPANSION VALVES Selective Thermostat Charges Designed to provide optimum performance for all applications air conditioning and heat pump, medium and
More informationInstallation, Start-Up and Service Instructions
38AH044-134 Air-Cooled Condensing Units 50/60 Hz Installation, Start-Up and Service Instructions CONTENTS Page SAFETY CONSIDERATIONS...................... 1 INSTALLATION................................
More informationPARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer
PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer 5/16 Rev. A 57-02509 2 Contents INTRODUCTION... 4 WARNING LABELS AND SAFETY INSTRUCTIONS... 5 PS SERIES PARALLEL
More information10/4/2013. The Changing State of Refrigerants
10/4/2013 The Changing State of Refrigerants Refrigerant Chemistry CFC = Chlorofluorocarbon Rapid phase-out Stopped U.S. production in 1996 R-11, R-12, R-113, R-114, R-500, R-502 HCFC = Hydrochlorofluorocarbon
More informationReduce everything but reliability
Milk Cooling Tanks Reduce everything but reliability The dairy industry world has been through many changes with historically increasing operating costs and lower milk prices. Danfoss is commiteed to its
More information.2 Section Waste Management and Disposal.
Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3
More informationBrazed Plate Heat Exchanger for CO Applications
Brazed Plate Heat Exchanger for CO Applications www.kaori-bphe.com CO 2 (R744) Due to global warming, climate change phenomenon, and rising restriction on the use of high GWP synthetic refrigerant; replacing
More informationThis chapter is divided into four sections:
Danfoss Fitters notes Danfoss This chapter is divided into four sections: Page Mounting instructions............................................................................ 63 ondensing units in general......................................................................
More informationMAC N-407 Air-Cooled Chiller
MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=
More informationRetrofit and High Glide Refrigerants
Technical paper Retrofit and High Glide Refrigerants Danfoss statement By Norbert Blatz, Global Application Excellence Manager, John Broughton, Global Application Expert, Commercial Refrigeration, Rasmus
More informationcompact BOOSTER RACK TRANSCRITICAL CO 2 Cooling capacity LT: from 2 to 130 kw Cooling capacity MT: from 20 to 300 kw
w w w. p r o f r o i d. c o m compact TRANSCRITICAL CO 2 BOOSTER RACK Cooling capacity LT: from 2 to 130 kw Cooling capacity MT: from 20 to 300 kw compact Refrigeration Rack Transcritical CO 2 booster
More informationTechnical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler
Technical Development Program COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7 Introduction System
More informationCompressors, Chillers & Condensers
Totaline s water-cooled condensers are designed for a wide range of applications and are available in many models ranging from 5 to 400 nominal tons. Small and large condensers are available for fresh
More informationGLYCOL REGENERATIVE METHOD A
SERVICES, INC. GAS DEHYDRATION Through the TRIETHYLENE GLYCOL REGENERATIVE METHOD A Basic Seminar on the Operation of TEG Systems I PRINCIPLES AND OPERATION OF GLYCOL DEHYDRATORS WATER IS PRODUCED WITH
More informationLARDER Instruction booklet
TM LARDER Instruction booklet RTL266WHA+ Index BEFORE USING YOUR FRIDGE... 2 General warnings... 2 Old and out-of-order fridges... 4 Safety warnings... 4 Installing and Operating your Fridge... 5 Before
More informationMAKING MODERN LIVING POSSIBLE. MLZ / MLM Refrigeration scroll compressors Hz - R404A - R507 - R134a - R22. Selection & application guidelines
MAKING MODERN LIVING POSSIBLE MLZ / MLM Refrigeration scroll compressors 50-60 Hz - R404A - R507 - R134a - R22 Selection & application guidelines Contents Features... 4 Scroll compression principle...
More informationORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.
ORTEC Compressed Air, Gas & Fluid Technologies t a l r o n m e n i l y E n v F r i e n d t r a n l y R e i g e f r INDUSTRIAL FLUID CHILLERS FC SERIES (0-00 TONS) Application Flexibility Nortec Industrial
More informationDRYPACK. Protecting installations Energy optimisation. Operating principle. Description. Biogas dehumidification system. Improved profitability.
Protecting installations Energy optimisation Improved profitability Flow rate of conditioned biogas: up to 6 000 Nm 3 /h Biogas efficient waste recovery Operating principle When produced, biogas contains
More informationRefrigerant R407C CW-AR. 2.4 to 3.1kW. Water Source Heat Pumps - Vertical Mounting Version Models 07 to to 2.7kW
Refrigerant R407C CW-AR Water Source Heat Pumps - Vertical Mounting Version Models 07 to 12 2.4 to 3.1kW 1.9 to 2.7kW Some advantages... RAL 9010 painted cabinet 3-fan speeds G2 filter is supplied as
More informationCommercial CO 2 Refrigeration Systems
Commercial CO 2 Refrigeration Systems Guide for Subcritical and Transcritical CO 2 Applications 2 Contents Chapter 1. Introduction 4 Chapter 2. CO 2 Basics and Considerations as a Refrigerant 5 Section
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02
More information50% Refrigeration solutions to lower energy costs and reduce environmental impact. Foodservice Solutions. Up to
Foodservice Solutions Refrigeration solutions to lower energy costs and reduce environmental impact Up to 50% energy savings; direct benefit to the bottom line www.danfoss.com Elevating Your Offering Energy
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -
More information