LINE COMPONENTS VALVES

Size: px
Start display at page:

Download "LINE COMPONENTS VALVES"

Transcription

1 VALVES DANFOSS THERMOSTATIC EXPANSION VALVES - T2 T2 thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. The refrigerant superheat determines the amount. Large temperature range, suitable for freezing, refrigeration and air conditioning applications. Interchangeable orifice assembly MOP Valves (Max. Operating Pressure) availiable - protects the compressor motor against excessive evaporating pressure during normal operation. DESCRIPTION REFRIGERANT TEMPERATURE RANGE C EQUALISED CONNECTIONS TYPE IN. OUT. BDA Z3206 TX2 R22/R407C +10 TO -40 INT 3/8 1/2 FLARE BDA Z3209 TEX2 R22/R407C +10 TO -40 EXT 3/8 1/2 BDA Z3281 TX2S R22/R407C +10 TO -40 INT 3/8 1/2 BDA Z3284 TEX2S R22/R407C +10 TO -40 EXT 3/8 1/2 BDA Z3346 TN2 R134A +10 TO -40 INT 3/8 1/2 FLARE BDA Z3348 TEN2 R134A +10 TO -40 EXT 3/8 1/2 BDA Z3383 TN2S R134A +10 TO -40 INT 3/8 1/2 BDA Z3385 TEN2S R134A +10 TO -40 EXT 3/8 1/2 BDA Z3389 TEN2 MOP55 R134A (MOP55) -40 TO 10 EXT FLARE 3/8 1/2 BDA Z3400 TS2 R404A/R TO -40 INT 3/8 1/2 FLARE BDA Z3403 TES2 R404A/R TO -40 EXT 3/8 1/2 BDA Z3414 TS2S R404A/R TO -40 INT 3/8 1/2 BDA Z3415 TES2S R404A/R TO -40 EXT 3/8 1/2 BDA Z3408 TS2 MOP 50 BDA Z3409 TES2 MOP50 R404A/R507 (MOP50) R404A/R507 (MOP50) -40 TO -15 INT 3/8 1/2 FLARE -40 TO -15 EXT 3/8 1/2

2 VALVES DANFOSS ORIFICE - T2 NOMINAL CAPACITY ORIFICE NUMBER R22 R134A R404A -5SST -25SST -5SST -25SST -5SST -25SST BDA X BDA BDA BDA BDA BDA BDA BDA Based on 45 C condensing temperature. 4k Subcooling. Factory setting = 5K Increase superheat - Clockwise turn, reduces flow Decrease superheat - Anti-clockwise turn, increases flow TX VALVE ISOLATION COVER Universal design, suitable for a range of brands Compact design suitable for internal and external balance Easy assembly Strong insulating properties Temperatures down to -45 C Ice blocking Stylish appearance DESCRIPTION BDA1000 CFTXCOV Isolation Cover Tx Valve

3 VALVES DANFOSS THERMOSTATIC EXPANSION VALVES - TE5 TO TE55 The TE series expansion valve regulates the injection of refrigerant into evaporators. It controls the refrigerant flow based on the superheat. The exchangeable power element is produced with Danfoss laser welding technology for extended lifetime capability. Interchangeable orifice assembly. Stainless steel power element, capillary tube and bulb. Wide capacity range. Superior charge performance. Balanced orifice design on TE55 series. DANFOSS ELEMENTS - T5 DESCRIPTION REFRIGERANT TEMPERATURE RANGE C EQUALISED TYPE BDA B3250 TEX5 R22/R407C BDA B3297 TEN5 R134A BDA B3342 TES5 R404A/R TO +10 EXT BDA B3358 TES5 MOP45 R404A/R507 (MOP45) -40 TO -15 DANFOSS VALVE BODY - T5 DESCRIPTION DIRECTION CONNECTION TYPE IN. OUT. BDA B4009 T5 Body ANGLE 1/2 5/8 BDA B4007 T5 Body STRAIGHT 1/2 5/8 BDA B4010 T5 Body ANGLE 1/2 7/8 BDA B4008 T5 Body STRAIGHT 1/2 7/8 BDA B4013 T5 Body ANGLE FLARE 1/2 5/8 BDA B4011 T5 Body ANGLE 5/8 7/8 BDA B4034 T5 Body ANGLE 7/8 1 1/8

4 VALVES DANFOSS ORIFICE - T5 NOMINAL CAPACITY ORIFICE NUMBER R22/R407C R134A R404A/R507-5SST -25SST -5SST -25SST -5SST -25SST BDA B BDA B BDA B BDA B BDA B Based on 45 C condensing temperature. 4k Subcooling. Factory setting = 5K Increase superheat - Clockwise turn, reduces flow Decrease superheat - Anti-clockwise turn, increases flow DANFOSS ELEMENTS - T12 DESCRIPTION REFRIGERANT TEMPERATURE RANGE C EQUALISED TYPE BDA B3210 TEX12 R22/R407C BDA B3232 TEN12 R134A -40 TO +10 EXT BDA B3347 TES12 R404A/R507 DANFOSS VALVE BODY - T12 DESCRIPTION DIRECTION CONNECTION TYPE IN. OUT. BDA B4022 T12 Body ANGLE BDA B4020 T12 Body STRAIGHT BDA B4021 T12 Body ANGLE BDA B4023 T12 Body STRAIGHT 5/8 7/8 7/8 1 1/8 DANFOSS ORIFICE - T12 NOMINAL CAPACITY ORIFICE NUMBER R22/R407C R134A R404A/R507-5SST -25SST -5SST -25SST -5SST -25SST BDA B BDA B BDA B Based on 45 C condensing temperature. 4k Subcooling. Factory setting = 5K Increase superheat - Clockwise turn, reduces flow Decrease superheat - Anti-clockwise turn, increases flow

5 VALVES DANFOSS THERMOSTATIC EXPANSION VALVES - TUA/TUAE TUA/TUAE valves are made of stainless steel and can be used in many different forms of refrigeration systems, for example: Traditional refrigeration systems, Heat pump systems, Air conditioning units, Refrigeration appliances, Liquid coolers, Ice cube machines, Mobile refrigeration systems Interchangeable orifice assembly designed for easy mounting and optimized tightness Bimetal connections - Simple, fast soldering without the need for wet cloth or refrigeration pliers. Stable regulation Biflow function (orifice 1 to 8) Compact design - small dimensions and low weight Stainless steel, solder version - high connection strength and tightness - capillary tube joints of high strength and vibration resistance Laser-welded, stainless steel thermostatic diaphragm element - optimum function - long diaphragm life - high pressure resistance Stainless steel bulb - simple and fast installation - good heat transfer from pipe to bulb Interchangeable filter for easy cleaning DANFOSS TUA TX VALVES DESCRIPTION REFRIGERANT TEMPERATURE RANGE C EQUALISED CONNECTIONS TYPE IN. OUT. BDB U2205 TUA INT R134A BDB U2207 TUAE EXT +10 TO -40 BDB U2285 TUA INT R404A/R507 BDB U2287 TUAE EXT 3/8 1/2 NOMINAL CAPACITY ORIFICE NUMBER R134A R404A/R507-5SST -25SST -5SST -25SST BDB U BDB U BDB U BDB U BDB U BDB U BDB U BDB U BDB U BDB U Based on 45 C condensing temperature. 4k Subcooling. Factory setting = 4K Increase superheat - Clockwise turn, reduces flow Decrease superheat - Anti-clockwise turn, increases flow

6 Because each electronic TX valve can cover a huge capacity range, they are ideal for variable speed drive applications. By simulataneously adapting to superheat and capacity changes, they create the perfect balance of energy efficiency and system control. At Koldpak, we can select and supply the most appropriate valve for your application in an easy to install kit, including: Electronic Valve Valve controller Transformer Temperature probe Pressure transducer 3m interconnect cable Easy to follow instructions For expert advice on simple, effective power saving technology, call

7 AIR VALVES CONDITIONING UNIT MOUNTING BRACKETS EMERSON ELECTRONIC THERMOSTATIC EXPANSION VALVES - EX SERIES Emerson electrical control valves EX4, EX5, EX6, EX7 and EX8 are optimised for the control of liquid or gaseous mass flow in refrigeration systems. The stepper motor, which produces a precise valve opening, is energized directly from the electrical power and therefore operates independent from differential pressure ensuring stable operation at low condensing pressures. The valve seat and slider are made of solid ceramic for long life, low operating force, low internal leak rate and to eliminate corrosion. The positive shut off function and fast response time eliminate the need for an additional solenoid valve. The special shape of the valve slide provides for proper flow through the valve and a highly linear capacity characteristic between 10% and 100% of maximum capacity. Fully hermetic design Fast full stroke time Applicable to all common refrigerants (HCFC, HFC), for subcritical CO2 applications High resolution and excellent repeatability Bi-flow versions for heat pump applications Positive shut-off function to eliminate the use of an additional solenoid valve Linear flow capacity Wide capacity range (10-100%) Continuous modulation of mass flow, no stress (liquid hammering) in the refrigeration circuit Direct coupling of motor and valve for high reliability (no gear mechanism) Ceramic slide and port for accurate flow and minimal wear Balanced force design Corrosion resistant stainless steel body, and connections

8 AIR CONDITIONING UNIT MOUNTING BRACKETS VALVES EMERSON ELECTRONIC EXPANSION VALVE KITS DESCRIPTION INLET OUTLET CAPACITY RANGE Kw R 407C R 22 R 134a R 404A R 410A R 744 BDC0020 EX4-U31KIT BDC0040 EX5-U31KIT BDC0060 EX6-I31KIT BDC0080 EX7-U31KIT EX4-U31 Electronic Exp. Valve Kit EX5-U31 Electronic Exp. Valve Kit EX6-I31 Electronic Exp. Valve Kit EX7-U32 Electronic Exp. Valve Kit 5/8 5/ /8 7/ /8 1 1/ /8 1 3/ Kits include Bi-flow valves with identical capacity in both flow directions, electronic driver, transformer, NTC probe, transducer and connection kit. For capacity conditions, application examples or other technical data, please contact us. ELECTRONIC EXPANSION VALVE PARTS DESCRIPTION BDC0100 EX4-U31 Alco EX4-U31 Electronic Exp. Valve BDC0120 EX5-U31 Alco EX5-U31 Electronic Exp. Valve BDC0140 EX6-I31 Alco EX6-I31 Electronic Exp. Valve BDC0160 EX7-U31 Alco EX7-U32 Electronic Exp. Valve BDC0180 TF20D 20VA Transformer To Suit EXV 230/24v BDC0200 XEV22D Dixell EXV Driver BDC0220 NT6-67 Dixell NTC 3m Probe Suit EXV BDC0240 PP11 Pressure Transducer Bar EXV BDC0260 EXV-M15 Plug and lead 1.5m kit for EEV EX4-8 BDC0280 EXV-M30 Plug and lead 3.0m kit for EEV EX4-8 Parts available in combined kit form. EXV-M30 EX5-U31 XEV22D NT6-67 PP11 TRANSDUCER

9 AIR VALVES CONDITIONING UNIT MOUNTING BRACKETS DENALINE ROTALOCK VALVES With 30 years of experience and over 1 million valves manufactured each year: Denaline has the figures, know-how and technology you d expect from a true leader. Based in Italy, Denaline manufacture, quality-control and test their products in house, which are then distributed worldwide.they are a leading name in Europe and are recognised as such by virtue of their strong focus on quality, safety, technology and the environment. DESCRIPTION ROTALOCK PIPE ID BDD R Rotalock 3/4 RL x 3/8 Pipe 3/4 3/8 BDD R Rotalock 3/4 RL x 1/2 Pipe 3/4 1/2 BDD R Rotalock 1 RL x 3/8 Pipe 1 3/8 BDD R Rotalock 1 RL x 1/2 Pipe 1 1/2 BDD R Rotalock 1 RL x 5/8 Pipe 1 5/8 BDD R Rotalock 1-1/4 RL x 1/2 Pipe 1 1/4 1/2 BDD R Rotalock 1-1/4 RL x 5/8 Pipe 1 1/4 5/8 BDD R Rotalock 1-1/4 RL x 3/4 Pipe 1 1/4 3/4 BDD R Rotalock 1-1/4 RL x 7/8 Pipe 1 1/4 7/8 BDD R Rotalock 1-1/4 RL x 1-1/8 Pipe 1 1/4 1 1/8 BDD R Rotalock 1-3/4 RL x 7/8 Pipe 1 1/4 7/8 BDD R Rotalock 1-3/4 RL x 1-1/8 Pipe 1 3/4 1 1/8 BDD R Rotalock 1-3/4 RL x 1-3/8 Pipe 1 3/4 1 3/8 BDD R Rotalock 1-3/4 RL x 1-5/8 Pipe 1 3/4 1 5/8 BDD R Rotalock 2-1/4 RL x 1-5/8 Pipe 2 1/4 1 5/8 BDD R Rotalock 2-1/4 RL x 2-1/8 Pipe 2 1/4 2 1/8

10 VALVES AIR CONDITIONING UNIT MOUNTING BRACKETS DENALINE PRESSURE RELIEF VALVES Individually certified, these Italian made pressure relief valves open gradually and reset quickly to minimise refrigerant loss in the event of an increase in pressure. DESCRIPTION CONNECTIONS INLET NPT OUTLET PSI BAR kpa BDE0020 DLD10/CS Pressure Relief Valve 1/2 3/ To meet increasingly demanding specifications, the Denaline Dual Shut-off Valve allows the isolation of individual pressure relief valves for servicing and testing. DESCRIPTION CONNECTIONS INLET NPT OUTLET BDE S Three-Way Dual Shut-off Valve 1/2 2 X 1/2 RANCO 4 WAY REVERSING VALVE - 240V COIL & LEAD INCLUDED CONNECTIONS NOM KW (R22) NOM KW (R410A) DISCH. SUCT. MIN MAX MIN MAX TON BDF0020 V IL 3/8 1/ BDF0040 V IL 1/2 5/ BDF0060 V IL 1/2 3/ BDF0080 V IL 1/2 7/ BDF0100 V IL 1/2 7/ BDF0120 V IL 3/4 7/ BDF0140 V IL 7/8 1 1/ BDF0160 V T4-2IL 1 1/8 1 3/ * Capacity based on +7.2deg evaporating / 54.4deg condensing. Max capacity at 14kPa pressure drop

11 AIR VALVES CONDITIONING UNIT MOUNTING BRACKETS RANCO REPLACEMENT OIL DESCRIPTION BDF0200 RANL Reversing Valve Coil 240v BDF0220 RAN Reversing Valve Coil 24v SHUT OFF VALVES CAPPED LINE VALVES FLARE FLARE BDG0020 1/4 BDG0040 3/8 BDG0060 1/2 BDG0080 5/8 BDH0020 1/4 BDH0040 3/8 BDH0060 1/2 BDH0080 5/8 BDG0100 1/4 BDG0120 3/8 BDG0140 1/2 BDG0160 5/8 BDH0100 1/4 BDH0120 3/8 BDH0140 1/2 BDH0160 5/8 DANFOSS CHECK VALVES FLARE TYPE BDI /4 STRAIGHTWAY BDI /8 STRAIGHTWAY BDI /2 STRAIGHTWAY BDI /8 STRAIGHTWAY BDI /4 ANGLEWAY TYPE BDI /4 STRAIGHTWAY BDI /8 STRAIGHTWAY BDI /2 STRAIGHTWAY BDI /8 STRAIGHTWAY BDI /4 ANGLEWAY BDI /8 ANGLEWAY BDI /8 ANGLEWAY BDI /8 ANGLEWAY

12 AIR CONDITIONING UNIT MOUNTING BRACKETS VALVES EMERSON BALL VALVES - WITH ACCESS PORT The BVS Ball valve is a fully hermetic ball valve for the Refrigeration and A/C industry. Two threads at valve body for easy mounting Hermetic design Compatible with high pressure refrigerants such as R 410A and CO2 (sub-critical) Light weight design Virgin PTFE seat gaskets Bi-directional flow characteristics Valve cap retained by strap attached to main body Pressure relief port design Full flow design (minimal pressure drop) 1/4 Access port with schrader core BDJ0020 BVS-014 1/4 BDJ0040 BVS-038 3/8 BDJ0060 BVS-012 1/2 BDJ0080 BVS-034 5/8 BDJ0100 BVS-058 3/4 BDJ0120 BVS-078 7/8 BDJ0140 BVS /8 BDJ0160 BVS /8 BDJ0180 BVS /8 BDJ0200 BVS /8 TECHNICAL DATA Maximum allowable pressure PS Test pressure PT Burst pressure Medium temp. TS 45 bar 49,5 bar 225 bar C (150 C short term) Construction Medium compatibility * Material Forged brass body, Copper extension tubes, Chrome plated ball HFC, HCFC, CO2, Mineral, Synthetic and Polyol-Ester (POE) lubricants Body CW617N, Copper Tubes CW 024A acc. EN12420 * BVS Ball valves are not released for use with caustic, poisonous or flammable substances.

13 AIR VALVES CONDITIONING UNIT MOUNTING BRACKETS DANFOSS CRANKCASE PRESSURE REGULATORS Crankcase pressure regulator type KVL is fitted in the suction line ahead of the compressor. KVL protects the compressor motor against overload during start-up after long standstill periods or after defrost periods (high pressure in evaporator). PART NO. FLARE BDK L0041 KVL12 1/2 BDK L0042 KVL15 5/8 PART NO. BDK L0043 KVL12S 1/2 BDK L0049 KVL15S 5/8 BDK L0045 KVL22S 7/8 BDK L0046 KVL28S 1 1/8 BDK L0052 KVL35S 1 3/8 DANFOSS EVAPORATOR PRESSURE REGULATORS KVP evaporator pressure regulators are fitted in the suction line of refrigeration and air conditioning systems. They are used to: Maintain a constant pressure equivalent to a constant temperature on the evaporator. Protect against a dangerously low evaporating pressure by throttling down when pressure falls below the set value. Differentiate the evaporating pressures in two or more evaporators in systems with one compressor. PART NO. FLARE BDL L0021 KVP12 1/2 1/2 BDL L0022 KVP15 5/8 PART NO. BDL L0023 KVP12S 1/2 BDL L0029 KVP15S 5/8 BDL L0025 KVP22S 7/8 BDL L0026 KVP28S 1 1/8 BDL L0032 KVP35S 1 3/8

14 AIR CONDITIONING UNIT MOUNTING BRACKETS VALVES DANFOSS SOLENOID VALVES Danfoss EVR valves are suitable for liquid, suction, and hot gas lines. They are compatible with a wide choice of coils for AC and DC and are designed for temperatures of up to 105 C. PART NO. FLARE FUNCTION PART NO. FUNCTION BDN F8107 EVR3 1/4 N/C BDN F8116 EVR3 3/8 N/C BDN F8072 EVR6 3/8 N/C BDN F8079 EVR6 1/2 N/C BDN F8095 EVR10 1/2 N/C BDN F8098 EVR10 5/8 N/C BDN F8101 EVR15 5/8 N/C BDN F1206 EVR3S 1/4 N/C BDN F1204 EVR3S 3/8 N/C BDN F1212 EVR6S 3/8 N/C BDN F1209 EVR6S 1/2 N/C BDN F1217 EVR10S 1/2 N/C BDN F1214 EVR10S 5/8 N/C BDN F1228 EVR15S 5/8 N/C BDN F1225 EVR15S 7/8 N/C BDN F1240 EVR20S 7/8 N/C BDN F2201 EVR25S 1 1/8 N/C BDN H1106 EVR32S 1 3/8 N/C BDN H1112 EVR40S 2 1/8 N/C * Above solenoid valves do not include coils. Please see below. DANFOSS SOLENOID COILS PART NO. CONNECTION TYPE VOLTS WATTS BDN F6702 IP67 Terminal Box 240AC 10 BDN F6252 With Lead 240AC 10 BDN F6730 IP67 Terminal Box 110AC 10 BDN F6706 IP67 Terminal Box 12AC 10 BDN F6707 IP67 Terminal Box 24AC 10 BDN F6856 IP67 Terminal Box 12DC 20 BDN F6857 IP67 Terminal Box 24DC 20 *To suit EVR Solenoid Valves

15 DRIERS DANFOSS LIQUID LINE FILTER DRIER DML Danfoss DML driers have a core composition of 100% Molecular Sieve making them ideal for applications requiring the highest moisture capacity. High drying capacity minimising the risk of acid formation The drier shell has a powder-painted corrosion resistant finish Sizes ranging from 3 75 cubic inches The filter is thermally stable up to 120 C. DANFOSS LIQUID LINE FILTER DRIER DML - FLARE PART NO. FLARE LIQUID CAPACITY KW R22 R134A R404A BDO Z5035 DML32 1/ BDO Z5036 DML33 3/ BDO Z5037 DML52 1/ BDO Z5038 DML53 3/ BDO Z5039 DML82 1/ BDO Z5040 DML83 3/ BDO Z5041 DML84 1/ BDO Z5042 DML162 1/ BDO Z5043 DML163 3/ BDO Z5044 DML164 1/ BDO Z5045 DML165 5/ BDO Z0049 DML303 3/ BDO Z0050 DML304 1/ BDO Z0051 DML305 5/ BDO Z0193 DML306 3/ BDO Z0108 DML413 3/ BDO Z0109 DML414 1/ BDO Z0110 DML415 5/

16 DRIERS DANFOSS LIQUID LINE FILTER DRIER DML - PART NO. LIQUID CAPACITY KW R22 R134A R404A BDO Z5048 DML32S 1/ BDO Z5050 DML33S 3/ BDO Z5053 DML52S 1/ BDO Z5054 DML53S 3/ BDO Z5057 DML82S 1/ BDO Z5058 DML83S 3/ BDO Z5061 DML84S 1/ BDO Z5063 DML162S 1/ BDO Z5064 DML163S 3/ BDO Z5067 DML164S 1/ BDO Z5068 DML165S 5/ BDO Z0067 DML303S 3/ BDO Z0068 DML304S 1/ BDO Z0069 DML305S 5/ BDO Z0070 DML306S 3/ BDO Z0071 DML307S 7/ BDO Z0111 DML414S 1/ BDO Z0112 DML415S 5/ BDO Z0113 DML417S 7/ BDO Z0114 DML419S 1 1/ ARI : -15 c evaporating temp, 30 c condensing temperature and.07 bar

17 DRIERS DANFOSS BURNOUT DRIER DAS Danfoss DAS burnout driers are used in the suction line to clean up refrigeration and AC-systems with fluorinated refrigerants after a compressor motor burn-out. The solid core is composed of 70% activated alumina and 30% Molecular Sieve which works to absorb harmful acids as well as moisture. By absorbing these acids, the DAS burn-out filter drier protects the new compressor from premature failure. 2 Schrader access valves to measure pressure drop across the drier Sizes ranging from 8 to 60 cubic inches, The drier shell has a powder-painted corrosion resistant finish Allows installation in any position provided the flow is in the arrow direction PART NO. RATED CAPACITY KW Qe R22 R134A R404A BDO Z1009 DAS164S 1/ BDO Z1008 DAS165S 5/ BDO Z1012 DAS167S 7/ BDO Z1013 DAS305S 5/ BDO Z1014 DAS306S 3/ BDO Z1015 DAS307S 7/ BDO Z1016 DAS309S 1 1/ Capacity is rated at 4 C evaporating temp,.21bar Capacities for other temperatures than 4 C are calculated by use of correction factors. Divide your actual evaporator capacity with the correction factor given for your actual evaporating temperature. Look up the capacity table for the necessary rated capacity. Qe/Fe = Qn Qe = Actual evaporator capacity Qn = Nominal capacity Fe = Correction factor Correction factors. Fe evaporating temperatures [ C] [ C] Fe Example To select a burn-out filter drier for a R134a plant with an evaporator capacity at 8.5 kw at -5 C you may use a burn-out filter drier with a rated capacity of 8.5/0.75 = kw or bigger. For example DAS 305.

18 DRIERS DANFOSS BI FLOW DRIER DMB Bi-flow filter driers have built-in check valves which ensure that refrigerant liquid always flows through the filter driers from the outer side of the filter core towards the centre. Thus all dirt particles are retained irrespective of flow direction. DCB filter driers ensure fast and effective absorption of moisture as well as organic and inorganic acids. High drying capacity minimising the risk of acid formation Seamless core blend for systems operating at high condensing temperatures and require high drying capacity No dirt released by reversing the flow direction Sizes ranging from 8 30 cubic inches DANFOSS BI FLOW DRIER DMB - FLARE PART NO. FLARE LIQUID CAPACITY KW R22 R134A R404A BDO Z1412 DMB82 1/ BDO Z1411 DMB83 3/ BDO Z1410 DMB84 1/ BDO Z1415 DMB163 3/ BDO Z1414 DMB164 1/ BDO Z1413 DMB165 5/ DANFOSS BI FLOW DRIER DMB - PART NO. LIQUID CAPACITY KW R22 R134A R404A BDO Z1443 DMB82S 1/ BDO Z1442 DMB83S 3/ BDO Z1441 DMB84S 1/ BDO Z1446 DMB163S 3/ BDO Z1445 DMB164S 1/ BDO Z1444 DMB165S 5/ BDO Z1447 DMB307S 7/ ARI : -15 c evaporating temp, 30 c condensing temperature and.07 bar

19 DRIERS ESK FILTER DRIERS Solid cores are easily replaceable Drier can be used alternatively as a fine strainer element after removal of solid core Schrader fitting to measure pressure drop Steel connector fittings Epoxy coating for surface protection CORE BDO1580 FT1X-3/4 3/4 1 BDO1600 FT1X-22 7/8 1 BDO1620 FT1X /8 1 BDO1640 FT1X /8 1 BDO1660 FT1X /8 1 BDO1680 FT1X /8 1 BDO1700 FT1X-2.5/8 2 5/8 1 BDO1720 FT2X /8 2 BDO1740 FT2X /8 2 BDO1760 FT2X /8 2 DRIER CORES DESCRIPTION SUITABILITY MATERIAL BDO2999 Suction Mesh Filter All refrigerants. Reuseable Stainless steel BDO3000 Core Standard General Clean Up All Round Clean-up (not recommended for POE oil) 80%MS, 20%AL BDO3020 Core Burn-Out Complete Clean Up Not recomended for long time use especially with POE 60%MS, 35%AL, 5%AC BDO3040 Core Ultra Drier HD Moisture Ideal for POE 100% MS MS = Molecular sieve AL = Activated Alumina AC = Activated Carbon

20 SIGHT GLASS DANFOSS MOISTURE INDICATOR - SIGHT GLASS SGN Sight glasses are used to indicate: 1. The condition of the refrigerant in the liquid line of the plant. 2. The flow in the oil return line from the oil separator. 3. The moisture content in the refrigerant. The Danfoss SGN are equipped with sensitive indicators that reflects a colour, depending on the moisture content in the refrigerant. Indicates excess water content in the refrigeration system Indicates lack of subcooling DANFOSS MOISTURE INDICATOR - SIGHT GLASS - FLARE NO. BRAND FLARE BDP SGN6 1/4 BDP SGN10 3/8 BDP SGN12 1/2 BDP SGN16 5/8 BDP SGN19 3/4 DANFOSS MOISTURE INDICATOR - SIGHT GLASS - NO. BRAND BDP SGN6S 1/4 BDP SGN10S 3/8 BDP SGN12S 1/2 BDP SGN16S 5/8 BDP SGN19S 3/4 BDP SGN22S 7/8 DANFOSS MOISTURE INDICATOR - SIGHT GLASS - MALE/FEMALE NO. BRAND MALE/ FLARE BDP SGN6 1/4 BDP SGN10s 3/8 BDP SGN12 1/2 BDP SGN16 5/8 BDP SGN19 3/4

21 VIBRATIONELIMINATORS PACKLESS VIBRATION ELIMINATORS Vibration Eliminators can be installed in both suction and discharge line of air conditioning, heat pump and refrigeration systems. The function of a vibration eliminator is to absorb the vibrations caused by the compressor. Ø D1 L (+/ 5) inch mm BDQ0020 VAF3 3/8 250 BDQ0040 VAF4 1/2 270 BDQ0060 VAF5 5/8 290 BDQ0080 VAF6 3/4 270 BDQ0100 VAF8 7/8 330 BDQ0120 VAF9 1 1/8 370 BDQ0140 VAF10 1 3/8 420 BDQ0160 VAF11 1 5/8 432 BDQ0180 VAF82 2 1/8 508 BDQ0200 VAF83 2 5/8 610

T2 thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. The refrigerant superheat determines the amount.

T2 thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. The refrigerant superheat determines the amount. DANFOSS THERMOSTATIC EXPANSION - T2 T2 thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. The refrigerant superheat determines the amount. FEATURES Large temperature

More information

Thermostatic Expansion valves, type TUA/TUAE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Thermostatic Expansion valves, type TUA/TUAE REFRIGERATION AND AIR CONDITIONING. Technical leaflet Thermostatic Expansion valves, type A/AE REFRIGERATION AND AIR CONDITIONING Technical leaflet Thermostatic expansion valves, type A/AE Contents Page Introduction... Features... Standard range... Technical

More information

FSW SECTION. Product guide. Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches F SECTION. 71

FSW SECTION. Product guide. Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches F SECTION.   71 FSW Product guide F SECTION Expansion Valves, Solenoid Valves Water Valves & Oil Pressure Switches For more information visit www.fsw.uk.com 71 Danfoss Expansion Valves T* Range - Order valve and orifice

More information

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Capacity regulator (hot gas bypass), type TUH/TCHE/TRHE REFRIGERATION AND AIR CONDITIONING. Technical leaflet Capacity regulator (hot gas bypass), type TUH/TCHE/ REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction........................................................................................3

More information

Flexible. Upgrade and service with ease Extend lifetime with modular design. Thermostatic expansion valves Type TE5-55

Flexible. Upgrade and service with ease Extend lifetime with modular design.   Thermostatic expansion valves Type TE5-55 MAKING MODERN LIVING POSSIBLE Upgrade and service with ease Extend lifetime with modular design Thermostatic expansion valves Type TE5-55 Flexible Upgrade with backward compatible valve technology. Mix

More information

MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valves, type TR 6 REFRIGERATION & AIR CONDITIONING DIVISION.

MAKING MODERN LIVING POSSIBLE. Thermostatic expansion valves, type TR 6 REFRIGERATION & AIR CONDITIONING DIVISION. MAKING MODERN LIVING POSSIBLE Thermostatic expansion valves, type REFRIGERATION & AIR CONDITIONING DIVISION Technical leaflet Technical leaflet Thermostatic expansion valves, type Contents Page Introduction........................................................................................3

More information

Thermostatic Expansion Valves Type TR 6

Thermostatic Expansion Valves Type TR 6 MAKING MODERN LIVING POSSIBLE Data sheet Thermostatic Expansion Valves Introduction The series is a hermetic tight design, designed and developed with features especially for use in applications such as:

More information

FSW. Product guide. Driers and Sight Glasses CSECTION For more information visit

FSW. Product guide. Driers and Sight Glasses CSECTION For more information visit FSW Product guide CSECTION Driers and Sight Glasses For more information visit www.fsw.uk.com 47 Copper Spun Driers Suitable for HFC, CFC and HCFC. CODE MODEL SIZE CONNECTIONS C440 MSCD-5-3 5 Gram 3/16"

More information

Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING. Technical leaflet Capacity regulators, type CPCE and LG REFRIGERATION AND AIR CONDITIONING Technical leaflet Introduction CPCE capacity regulators adapt compressor capacity to actual evaporator load. They are designed for

More information

Thermostatic expansion valves for ammonia Type TEA

Thermostatic expansion valves for ammonia Type TEA Data sheet Thermostatic expansion valves for ammonia Type TEA Thermostatic expansion valves regulate the injection of refrigerant liquid into evaporators. Injection is controlled by the refrigerant superheat.

More information

General information on refrigerant controllers

General information on refrigerant controllers General information on refrigerant controllers Condensing pressure controller The condensing or condenser pressure controller is a back pressure controller and its task is to maintain the condensing pressure

More information

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES SECTION 23 23 00 REFRIGERANT PIPING AND SPECIALITIES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Refrigerant piping. 2. Unions, flanges, and couplings. 3. Pipe hangers and supports. 4. Refrigerant

More information

Filter Driers with Replaceable Core

Filter Driers with Replaceable Core STANDARD Filter Driers with Replaceable Core The filter driers with replaceable core (HTG series) are used in liquid line and suction line of refrigerating, freezing and air conditioning system. The filter

More information

Hot gas bypass regulator, type CPCE Liquid gas mixer, type LG (accessory)

Hot gas bypass regulator, type CPCE Liquid gas mixer, type LG (accessory) Data sheet Hot gas bypass regulator, type CPCE Liquid gas mixer, type LG (accessory) CPCE hot gas bypass regulator adapt compressor capacity to actual evaporator load. They are designed for installation

More information

MAKING MODERN LIVING POSSIBLE. One valve for all purposes. TGE - thermostatic expansion valves REFRIGERATION & AIR CONDITIONING DIVISION

MAKING MODERN LIVING POSSIBLE. One valve for all purposes. TGE - thermostatic expansion valves REFRIGERATION & AIR CONDITIONING DIVISION MAKING MODERN LIVING POSSIBLE One valve for all purposes TGE - thermostatic expansion valves REFRIGERATION & AIR CONDITIONING DIVISION TGE: reliable, environmentally -friendly and easy to use Danfoss Refrigeration

More information

Accumulators - Suction Line

Accumulators - Suction Line ACCUMULATORS Accumulators - Suction Line kw Cap at Evap. Temp. -6 C Size Connection R22 R404A / R507C F0804 1/2" ODS Vertical 4.6 4.8 F0805 5/8" ODS Vertical 6.9 7.2 F0806 3/4" ODS Vertical 9.2 9.6 F0807

More information

Emerson Superheat Control. The smart solution for your application

Emerson Superheat Control. The smart solution for your application Emerson Superheat Control The smart solution for your application Trust in Emerson Climate Technologies for reliable, precise and efficient superheat control. When it comes to superheat control, Emerson

More information

500 EX Fusion Compressor Series

500 EX Fusion Compressor Series 500 EX Fusion Compressor Series R404A M/T R404A L/T Capacity RANGE 13.8kW - 20.4kW 7.7kW -11.2kW Copeland Fusion Semi-Hermetic Horizontal Scroll Compressors For Medium and Low Temperature Applications

More information

Product Catalog VALVES

Product Catalog VALVES SUIKA CLIMATE Product Catalog VALVES CONTACT WEB Info@suikaclimate.com ADDRESS Fremont, CA, 94555 TELEPHONE +1 (800) 625 0589 +1 (510) 859 8003 Suika Climate Toeflex ABOUT US Suika Climate (US), Toeflex

More information

SANHUA S OFFER FOR REFRIGERATION APPLICATIONS

SANHUA S OFFER FOR REFRIGERATION APPLICATIONS SANHUA S OFFER FOR REFRIGERATION APPLICATIONS Strive for perfection, Pursuit of excellence Sanhua is a leading HVAC&R manufacturer of controls and components with a global footprint and 30 years of experience.

More information

Easy Find the right products fast with our Quick Selection Guide. Products and technologies for all your application needs, today and tomorrow

Easy Find the right products fast with our Quick Selection Guide. Products and technologies for all your application needs, today and tomorrow Quick Selection Guide - 206 Products and technologies for all your application needs, today and tomorrow REFRIGERATION & AIR CONDITIONING Automatic Controls Condensing Units Compressors Easy Find the right

More information

Easy. Products and technologies for all your application needs, today and tomorrow. Quick Select Guide 2017

Easy. Products and technologies for all your application needs, today and tomorrow. Quick Select Guide 2017 Quick Select Guide 2017 Products and technologies for all your application needs, today and tomorrow REFRIGERATION & AIR CONDITIONING COMPONENTS Easy Find the right products fast with our Quick Select

More information

Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability

Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability Revolutionary ETS Colibri valves Engineered to give you maximum flexibility and dependability ETS Colibri brings to the market one of a kind, uniquely designed electric expansion valve. Innovative Design

More information

Zero ODP and negligible GWP when using hydrocarbons. Zero. portfolio for hydrocarbons.

Zero ODP and negligible GWP when using hydrocarbons. Zero. portfolio for hydrocarbons. Danfoss components for hydrocarbon refrigeration Leapfrog Extensive to a portfolio long-term and solution expertise with for safe Danfoss and optimised wide product use of hydrocarbons portfolio for hydrocarbons

More information

Check valve Types NRV and NRVH

Check valve Types NRV and NRVH Check valve s NRV and NRVH NRV and NRVH can be used in liquid. suction and hot gas lines in refrigeration and air conditioning plant with HCFC. HFC and HC flammable refrigerants. The valves ensure the

More information

HANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1

HANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1 HANDBOOK Ed. 2017 RP-ED 01/2017 - ENG 1 DIRECTIVE 2014/68/EU ISSUED OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 15 MAY 2014 ON PRESSURE EQUIPMENT Directive 2014/68/EU (PED Recast) applies to the design,

More information

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6 DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6 1.1. REFERENCE STANDARDS 1.2. GENERAL 1.1.1. The units shall be listed by Electrical Testing Laboratories (ETL) and bear the ETL label. 1.1.2.

More information

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s)

Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) Description Model(s) Page(s) INDEX UNIVERSAL ELECTRONIC CONTACTOR UPGRADE SURESWITCH 79 Description Model(s) Page(s) SureSwitch... 49P11-843... 79 CONTACTORS 80 82 Description Model(s) Page(s) 1 Pole... 94-388 Thru 94-395... 80 2

More information

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS Refrigerant R22 is widely used for residential and commercial air conditioning, as well as commercial refrigeration

More information

REFRIGERATION PRODUCTS

REFRIGERATION PRODUCTS SE REFRIGERATION PRODUCTS Smart Electric products offer reliable and longer lasting solutions for refrigeration. We know how important it is to keep systems clean and running at its full efficiency for

More information

Chapter-8 Capacity Control of Refrigeration Systems

Chapter-8 Capacity Control of Refrigeration Systems Chapter-8 Capacity Control of Refrigeration Systems Chapter-8 Capacity Control of Refrigeration Systems ၈.၁ Compressor Control Chiller Control and Chilled Water Plant Control Refrigeration system control

More information

Thermostatic Expansion Valves

Thermostatic Expansion Valves Thermostatic Expansion Valves Alco TI Series with Interchangeable Orifice Assembly TI Series Valves with interchangeable orifi ces provide the capability of changing capacity with only the change of an

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

Bulletin , March Electric Hot Gas Bypass Valves

Bulletin , March Electric Hot Gas Bypass Valves Bulletin 100-60, March 2018 Electric Hot Gas Bypass Valves PAGE 2 / Bulletin 100-60 10 FEATURES AND BENEFITS SDR-4 Direct temperature control Tight shutoff when closed Can be interfaced with direct digital

More information

Air-Cooled Condensing Units with Compact Screw Compressors

Air-Cooled Condensing Units with Compact Screw Compressors LK-SCUTB March 2015 Air-Cooled Condensing Units with Compact Screw s Technical Bulletin Models SSV DSV Table of Contents Nomenclature Chart... 2 Introduction... 3 Bitzer TM s... 4 Magnum TM Microprocessor...

More information

Energy Use in Refrigeration Systems

Energy Use in Refrigeration Systems 2012 Rocky Mountain ASHRAE Technical Conference Energy Use in Refrigeration Systems PRESENTED BY: Scott Martin, PE, LEED AP BD+C Objectives Understand mechanical refrigeration terms Describe how heat is

More information

REFRIGERANT CHANGEOVER

REFRIGERANT CHANGEOVER Date of last update: Dec-17 Ref: CC7.26.5/0117-1217/E Application Engineering Europe REFRIGERANT CHANGEOVER FROM HFC R134a TO HFC/HFO R450A & R513A WARNING Use only Emerson approved refrigerants and lubricants

More information

FSW SECTION. Product guide. Thermostats, Pressure Switches & Fan Speed Controls. E SECTION For more information visit

FSW SECTION. Product guide. Thermostats, Pressure Switches & Fan Speed Controls. E SECTION For more information visit FSW Product guide E SECTION Thermostats, Pressure Switches & Fan Speed Controls. 63 64 Head Office 01543 437 010 Danfoss Service Thermostat Kits TYPE TO SUIT E005 NO-1 Refrigerator E006 NO-2 Refrigerator

More information

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

SOLENOID VALVES FOR REFRIGERATING SYSTEMS SOLENOID VALVES FOR REFRIGERATING SYSTEMS APPLICATIONS The solenoid valves, shown in this chapter, are classified Pressure accessories in the sense of the Pressure Equipment Directive 97/23/EC, Article

More information

DESIGN STANDARDS SECTION 15600

DESIGN STANDARDS SECTION 15600 PART 1 - GENERAL 1.1 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.2 General requirements: A. Reciprocating

More information

DANFOSS OPTYMA PLUS INVERTER UNITS

DANFOSS OPTYMA PLUS INVERTER UNITS Optyma Plus Inverter Condensing Units Danfoss Optyma Plus Inverter Units are designed with the unique benefits of stepless inverter scroll technology resulting in a 20-30% higher energy efficiency in a

More information

PULSE WIDTH MODULATING VALVES

PULSE WIDTH MODULATING VALVES PULSE WIDTH MODULATING VALVES PARKER PULSE WIDTH MODULATING VALVES MODEL HP P4144 MODELS CS & DS P4145 Features Long life (100 million cycles). Suitable for all common refrigerants except ammonia. Maximum

More information

DDNCY (Temporary use)

DDNCY (Temporary use) Refrigeration & limate omponents Solutions 3.1 leaning bi-directional flow and TY-EN 3.1-5 / 02-2018 DDNY (Temporary use) n Applications leaning and decontamination of refrigerant circuits in refrigerating

More information

COMMECH SERIES AIR CONDITIONING CSH SEMI-HERMETIC SCREW PACKAGES. ORIGINAL MANUFACTURED EQUIPMENT Commech Series New Models BA AUS

COMMECH SERIES AIR CONDITIONING CSH SEMI-HERMETIC SCREW PACKAGES. ORIGINAL MANUFACTURED EQUIPMENT Commech Series New Models BA AUS COMMECH SERIES AIR CONDITIONING CSH SEMI-HERMETIC SCREW ACKAGES ORIGINAL MANUFACTURED EUIMENT Commech Series New Models BA-509-2 AUS roduct Features The BITZER ComMech Series compact screw compressor pack

More information

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure.

Refrigerant valves. Valves for precise control and optimum energy efficiency in refrigeration systems. Answers for infrastructure. Refrigerant valves Valves for precise control and optimum energy efficiency in refrigeration systems Answers for infrastructure. MVL661.. MVS661..N and matching ASR valve insert The new generation MVL661..

More information

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A900-22007), 120/208/240/1/60, R404A, LT/MT APPS Introduction The superheat controller is designed

More information

49 Danfoss Thermostat Kits Ranco Varifix Kits

49 Danfoss Thermostat Kits Ranco Varifix Kits Danfoss Thermostat Kits Code Type To Suit E005 NO-1 Kit Refrigerator E006 NO-2 Refrigerator Push/Defrost E007 NO-3 Fridge Freezer/Larder Fridge E008 NO-4 Absorption Refrigerator E009 NO-5 Freezer E010

More information

Refrigeration and Air Conditioning Controls. Applications. PM Modulating pressure and temperature regulators REFRIGERATION AND AIR CONDITIONING

Refrigeration and Air Conditioning Controls. Applications. PM Modulating pressure and temperature regulators REFRIGERATION AND AIR CONDITIONING Refrigeration and Air Conditioning Controls Applications PM Modulating pressure and temperature regulators REFRIGERATION AND AIR CONDITIONING Introduction Danfoss PM regulators have been on the market

More information

RCY. Filter drier receiver units 4.1. Refrigeration & Climate Components Solutions. n Applications

RCY. Filter drier receiver units 4.1. Refrigeration & Climate Components Solutions. n Applications Refrigeration & limate omponents Solutions 4.1 n Applications Refrigerant filtering and drying, and acid neutralization for refrigerating and air conditioning installation liquid lines. The filter driers

More information

Sealed Type Liquid Line and Suction Line Specifications

Sealed Type Liquid Line and Suction Line Specifications CATALOG 0 Page,, 4a, 404A, 407C, 40A, 0, 07 Also Compatible with Refrigerants, 4,, 40A & B, 40A & B, 408A, 409A The universal acceptance of the Catch-All Filter-Drier is due to its unique molded porous

More information

64 bar. DCY-P6 / 64 bar (928 psig) Anti-acid filter driers 1.9. subcritical. Refrigeration & Climate Components Solutions.

64 bar. DCY-P6 / 64 bar (928 psig) Anti-acid filter driers 1.9. subcritical. Refrigeration & Climate Components Solutions. 1.9 DY-P6 / 64 bar (928 psig) n Applications Filtering and drying of refrigerants and acid neutralization for liquid lines of refrigerating and air conditioning installations, running with high working

More information

Dehydrators and Filters

Dehydrators and Filters Dehydrators and Filters DEHYDRATION OF REFRIGERANTS Among contaminating agents causing serious damages to refrigerating systems, moisture plays a major role. Its presence, even possible in the refrigerating

More information

Pressure switch KPU. Data sheet

Pressure switch KPU. Data sheet Data sheet Pressure switch KPU The KPU switches are designed for use in refrigeration and air-conditioning systems to protect the systems from excessively low suction or too high discharge. They can also

More information

November 2006 / BULLETIN ELECTRIC DISCHARGE BYPASS VALVES

November 2006 / BULLETIN ELECTRIC DISCHARGE BYPASS VALVES November 2006 / BULLETIN -60 ELECTRIC DISCHARGE BYPASS VALVES PAGE 2 / Bulletin -60 10 FEATURES AND BENEFITS Direct temperature control Tight shutoff when closed Can be interfaced with direct digital controls

More information

ELIMINATOR Hermetic filter drier for CO₂ DMSC for Sub-critical and DMT for Trans-critical application

ELIMINATOR Hermetic filter drier for CO₂ DMSC for Sub-critical and DMT for Trans-critical application Data sheet ELIMINATOR Hermetic filter drier for CO₂ DMSC for Sub-critical and DMT for Trans-critical application The filter drier is a vital element of the system s reliability as well as its lifespan.

More information

1+ SEER. 25% COP boost possible. Most valves expand your refrigerant EcoFlow expands your options. with silent defrost.

1+ SEER. 25% COP boost possible. Most valves expand your refrigerant EcoFlow expands your options.   with silent defrost. MAKING MODERN LIVING POSSIBLE Most valves expand your refrigerant EcoFlow expands your options 25% COP boost possible with silent defrost. 1+ SEER energy savings Reduce energy consumption and increase

More information

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1. Thomas J Kelly Sr. Engineering Instructor Carrier Corporation August 20, 2003 1 SESSION OBJECTIVES At the conclusion of this session you should be able to: 1. Describe the basics principles of refrigeration

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

PWM expansion valves 2028

PWM expansion valves 2028 PWM expansion valves 2028 Application Solenoid expansion valve Castel type 2028 regulates the refrigerant flow into the evaporator by modulating the opening time phase of the plug and so permitting a wide

More information

Technical Information

Technical Information Date of last update: May-12 Ref: : Application Engineering Europe ENHANCED VAPOUR INJECTION (EVI) FOR ZH*KVE SCROLL COMPRESSORS 1 Introduction... 2 2 Principle of operation... 2 3 Capacity effect... 3

More information

XSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1

XSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1 Page 1 WHY should I install the XSTREAM Valve System? XDX is more efficient, saving on power consumption. Use of XDX system decreases defrost cycles. XDX maintains more consistent product temperatures,

More information

Refrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Refrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A. Leading the Industry with Environmentally Responsible Refrigerant Solutions Refrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A Leading the Industry with Environmentally Responsible Refrigerant Solutions Emerson Climate Technologies, Inc. does not advocate

More information

DEHYDRATORS AND FILTERS

DEHYDRATORS AND FILTERS DEHYDRATORS AND FILTERS 91 DEHYDRATION OF REFRIGERANTS Among contaminating agents causing serious damages to refrigerating systems, moisture plays a major role. Its presence, even possible in the refrigerating

More information

PowerPoint Presentation by: Associated Technical Authors. Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois

PowerPoint Presentation by: Associated Technical Authors. Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois Althouse Turnquist Bracciano PowerPoint Presentation by: Associated Technical Authors Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois Chapter 5 Explain the purpose and operation of

More information

AE Application Guidelines for Refrigeration Copeland Discus Compressors with R-410A

AE Application Guidelines for Refrigeration Copeland Discus Compressors with R-410A AE4-1392 July 2014 Application Guidelines for Refrigeration Copeland Discus Compressors with R-410A Section TABLE OF CONTENTS Page Safety Safety Instructions...2 Safety Icon Explanation...2 Instructions

More information

Copeland Scroll Condensing Units for the Food Service Market

Copeland Scroll Condensing Units for the Food Service Market Copeland Scroll Condensing Units for the Food Service Market...with Best In Class Emerson System Protection Components Medium and Low Temperature Refrigeration Applications R-404A 1.5 to 10 Hp Reliable

More information

Refrigeration Systems and Accessories

Refrigeration Systems and Accessories As with the Chapter Review Tests and the Final Exam, the tests your understanding of the materials underlying the learning objectives. After you ve reviewed your answers to the Chapter Review Tests, try

More information

.2 Section Waste Management and Disposal.

.2 Section Waste Management and Disposal. Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3

More information

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER 2001829 OPERATIONS AND MAINTENANCE MANUAL Prepared by: 860 Douglas Way PO Box 530 Natural Bridge Station, VA 24579 1.0 SCOPE: This Operations and Maintenance

More information

Liebert CSU3000 Chiller

Liebert CSU3000 Chiller CSI 15620 - Packaged Water Chillers Liebert CSU3000 Chiller Guide Specifications for 7.5-37 Ton CS/CD/CT Models 1.0 GENERAL 1.1 CS/CD MODELS The main-frame coolant supply unit shall be a Liebert Model,

More information

June 2001 / BULLETIN Way Valves. The right solenoid valve for any job.

June 2001 / BULLETIN Way Valves. The right solenoid valve for any job. June 01 / BULLETIN - 3-Way Valves The right solenoid valve for any job. Page 2 / Bulletin - Advantages Sporlan 3-Way Valves 3-Way Pilot eliminates costly high- to low-side leaks. "B" reduces total installed

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

Low Pressure Sight Glass Up to 35 bar MWP Type SG

Low Pressure Sight Glass Up to 35 bar MWP Type SG MAKING MODERN LIVING POSSIBLE Technical brochure Low Pressure Sight Glass Up to 35 bar MWP Type SG www.danfoss.com Introduction Sight glasses are used to indicate:. The condition of the refrigerant in

More information

30GT FLOTRONIC AIR-COOLED CHILLERS

30GT FLOTRONIC AIR-COOLED CHILLERS 30GT-41SB 30GT040-110 FLOTRONIC AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GT-41SB Supersedes 30GT-21SB, 30GT-22SB, 30GT-23SB, Printed

More information

Suction Accumulators. Introduction. Suction Accumulators

Suction Accumulators. Introduction. Suction Accumulators Introduction The purpose of the Suction Accumulator is to provide temporary storage for any liquid refrigerant and oil that is returning to the compressor from the evaporator. The accumulator s internal

More information

YCAL-SB Millennium AIR COOLED LIQUID CHILLER R407C REFRIGERANT. COOLING CAPACITIES 141 kw to 360 kw

YCAL-SB Millennium AIR COOLED LIQUID CHILLER R407C REFRIGERANT. COOLING CAPACITIES 141 kw to 360 kw YCAL-SB Millennium AIR COOLED LIQUID CHILLER R407C REFRIGERANT COOLING CAPACITIES 141 kw to 360 kw YORK YCAL-SB Millennium air cooled scroll liquid chillers provide chilled liquid for all air conditioning

More information

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs next generation C precision controlled industrial process chillers cooling capacity: 6824 -,255,668 BTU /hr (0.6-04.6 tons) cooling capacity: 6,824 -,254,303 BTU/hr (0.6-04.5 tons) precision controlled

More information

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies Pakistan s Largest Manufacturers of Air-Conditioners PACKAGE TYPE UNIT FOR MOBILE APPLICATIONS Provides Turnkey Projects Conceptual Planning to Commissioning of HVACR Projects THE LARGEST MANUFACTURER

More information

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a Air-Cooled Variable Speed Drive Screw Chillers Super Efficient Super Quiet Cooling Capacity Range 540-1405 kw R134a World s first low sound Air-Cooled variable speed drive screw chiller The recognition

More information

30GN FLOTRONIC II AIR-COOLED CHILLERS

30GN FLOTRONIC II AIR-COOLED CHILLERS 30GN-19SB 30GN040-110 FLOTRONIC II AIR-COOLED CHILLERS PERFORMANCE DATA FIELD WIRING DIAGRAM 1998 Carrier Corporation Syracuse, New York 13221 Form 30GN-19SB Supersedes 30GN-6SB, 30GN-7SB, 30GN-8SB, Printed

More information

Research Design Quality Value Service Experience

Research Design Quality Value Service Experience 2017 INDEX ACCUMULATORS...27 ACCUMULATOR - DRIERS...27 CAPILLARY ASSEMBLIES Strainer...30 Strainer-Drier...29 CONDENSERS (WATER COOLED) Coaxial...19 Shell & Coil...18 DRIERS Big R...28 Junior...29 Filter...25

More information

One. Save time and money Streamline your heat pump business! makes a difference.

One. Save time and money Streamline your heat pump business! makes a difference. Save time and money Streamline your heat pump business! Heat Pump Components - Selection guide One makes a difference Add one more Danfoss component to your system and find out how all element add up to

More information

WHA WHA. Ground source water to water heat pumps A ++ A ++ Versions

WHA WHA. Ground source water to water heat pumps A ++ A ++ Versions WH ++ ++ +60 82 WH Ground source water to water heat pumps WH heat pumps are particularly suitable for applications that utilise ground source probes.these units have been designed for use with radiant

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION 100 TON AIR-COOLED SCROLL PACKAGED SPECIFICATIONS Call us today! (800)341-4297 Trane Portable Packaged Air Conditioner units contain the best compressor technology available, in order to achieve the highest

More information

MYSTICOOL Max Valve System with Xstream and A.R.M.E.D. Technology Service & Installation Instructions Page 1

MYSTICOOL Max Valve System with Xstream and A.R.M.E.D. Technology Service & Installation Instructions Page 1 Page 1 WHY should I install the MYSTICOOL Max Valve System? XDX is more efficient, saving on power consumption. Use of XDX system decreases defrost cycles. XDX maintains more consistent product temperatures,

More information

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units FORM NO. A22-194 REV. 2 Supersedes Form No. A22-194 Rev. 1 Commercial High-Efficiency Condensing Units RAWL High Efficiency 6.5 & 7.5 TON MODEL [22.86 & 26.38 kw] TABLE OF CONTENTS Model Number Designation...2

More information

EC3-X33 Stand-alone Superheat Controller Technical Data

EC3-X33 Stand-alone Superheat Controller Technical Data Technical Data EC3-X33 is a stand-alone universal superheat controller for air conditioning, refrigeration and industrial applications such as chillers, industrial process cooling, rooftops, heat pumps,

More information

R-407A R-448A R-449A

R-407A R-448A R-449A GUIDELINES FOR THE UTILIZATION OF R-407A R-448A R-449A 2018 Tecumseh Products Company LLC. All rights reserved. Page 1 of 9 R-407A, R-448A, and R-449A are recognized as suitable alternative refrigerants

More information

Refrigerant changeover guidelines

Refrigerant changeover guidelines Refrigerant changeover guidelines HCFC R-22 to HFC R-407A/F, R-448A or R-449A for medium and low temperature applications HCFC R-22 to HFC R-407C for high, medium and low temperature applications HCFC

More information

50% Refrigeration solutions to lower energy costs and reduce environmental impact. Foodservice Solutions. Up to

50% Refrigeration solutions to lower energy costs and reduce environmental impact. Foodservice Solutions.   Up to Foodservice Solutions Refrigeration solutions to lower energy costs and reduce environmental impact Up to 50% energy savings; direct benefit to the bottom line www.danfoss.com Elevating Your Offering Energy

More information

Condensing Units CUS 15-60

Condensing Units CUS 15-60 Condensing Units CUS 15-60 General Description UNIT IDENTIFICATION AIR COOLED CONDENSING UNIT CUS... Condensing Unit with Propeller Fan and Scroll Compressor 15-60... Model Size D... Double Circuit e.g....

More information

Optyma Slim Pack Condensing Units

Optyma Slim Pack Condensing Units Optyma Slim Pack Condensing Units Main Product Features Outdoor Applications Weatherproof Housing IP54 Robust and resistant to corrosion Compact design Crankcase Heater Service Shut Off Valves Micro Channel

More information

Air-Cooled Condensing Units with Bitzer Compressors

Air-Cooled Condensing Units with Bitzer Compressors CH-CUBZTB JAN 2018 Replaces CH-CUBZTB APRIL 2011 Air-Cooled Condensing Units with Bitzer s Technical Guide s BLV BDVS JLD JDDS Table of Contents Floating Tube Coil... 3 Beacon II Options... 4 Adjustable

More information

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F Temperature Control Units Water & Oil - F Portable Chillers Air & Water-Cooled - 7 F Central Chillers Air & Water-Cooled Packages & Modules - 7 F Pump Tank Stations Chilled or Tower Water - gallons Cooling

More information

Process glycol chillers

Process glycol chillers Process glycol chillers The most advanced solutions in refrigeration technology. According to normative EN378 y F-Gas Compact chillers for outdoor installation Natural refrigerant Integrated hydraulic

More information

VCYL. Liquid sight glasses 9.1 NEW. Refrigeration & Climate Components Solutions. Max WP 46 bar and multi-fluids (G1 or G2) n Applications

VCYL. Liquid sight glasses 9.1 NEW. Refrigeration & Climate Components Solutions. Max WP 46 bar and multi-fluids (G1 or G2) n Applications Refrigeration & limate omponents Solutions 9.1 n Applications Immediate and direct monitoring of flow, condition or moisture content of the refrigerant in its liquid or diphasic phase in refrigerating

More information

SECTION REFRIGERANT PIPING

SECTION REFRIGERANT PIPING SECTION 23783 REFRIGERANT PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Call us today! (800)

Call us today! (800) 150 TON AIR-COOLED CHILLER PA-ACCTR-150 Call us today! (800)341-4297 The 150-Ton portable chiller package features a Trane RTAC chiller unit. Trane leads the industry in providing some of the most reliable,

More information

10/4/2013. The Changing State of Refrigerants

10/4/2013. The Changing State of Refrigerants 10/4/2013 The Changing State of Refrigerants Refrigerant Chemistry CFC = Chlorofluorocarbon Rapid phase-out Stopped U.S. production in 1996 R-11, R-12, R-113, R-114, R-500, R-502 HCFC = Hydrochlorofluorocarbon