AEROLINE. fast easy reliable. The sophisticated connection technology for heat pumps

Size: px
Start display at page:

Download "AEROLINE. fast easy reliable. The sophisticated connection technology for heat pumps"

Transcription

1 AEROLINE WP The sophisticated connection technology for heat pumps Piping technology for solar, heating, heat pumps and air conditioning fast easy reliable

2 AEROLINE INOX TERRA WP 100 For air/water heat pumps installed outside 4 Technical Data 5 AEROLINE INOX TERRA WP SPLIT For air/water heat pumps in SPLIT placement and brine/water heat pumps 6 Technical Data 7 AERORAPID CLASSIC For the connection of outside air/water heat pumps installed next to the wall, brine/water heat pumps and hybrid heat pump systems. Technical Data For the distribution inside the building Condensation protection

3 AEROLINE INOX TERRA WP The perfect solution for the underground piping of air/water and brine/water heat pumps. The new AEROLINE INOX TERRA WP provides an absolutely sophisticated and simple turnkey system for the fast installation of heat pump line sets with smart options. The highlights are: The ground pipe system of pre-insulated corrugated stainless steel pipes provides maximum flexibility Bending radii Minimum bending radius 36 cm up to 50 cm Transport Smallest packing dimensions (Euro-skid) The complete system is simply and fast to install, minimal ground work is required. The cables can be slipped easily through the integrated liner pipe. Heat insulation Lowest heat loss values *AEROLINE INOX TERRA WP100 Ground work Reduction of the trench width Cable duct Integration of manufacturer specific control, sensor and power cables Linear expansion Firm setting of the corrugated stainless steel pipes act as integrated compensation of the linear expansion. No additional external fixing required The comprehensive sealing concept includes clever solutions for the jacket pipe and the wall duct and guarantees best tightness properties. Sealing Excellent building tightness (15 mws against water) Air tightness / condensation protection Lack of air exchange eliminates entry of humidity (condensate). Air infiltration and chimney effect are avoided (suitable for blower door-test) Made in Germany The portion of added value is higher 50% 3

4 AEROLINE INOX TERRA WP 100 Piping systems for the underground piping of outside installed air/water heat pumps. Modular turn-key system Double walled tube construction provides best protection against water ingress Exchange spacers for up to two control and sensor wires (5-15 mm) with plugs (up to a diameter of 45 mm) Highest thermal insulation properties thus better energy yield Internal fixing of the corrugated stainless steel tubes Appropriate also for heat pumps with reversible (cooling) operation System accessories: Jacket pipe sealing kit For the air and water tight seal of the jacket pipe and the fixing of the corrugated stainless steel tubes. AEROLINE Threaded connection kit For the connection to the heat pump and the heating unit. Jacket pipe thermal insulation kit For the high and low temperature insulation of the jacket pipe sealing kit. AEROSEAL Special adhesive For the waterproof sealing of insulation ends. Optional accessories: Wall sealing kit For the air and water tight sealing of the jacket pipe inside the wall. For the insertion of the appropriate liner pipes or core drillings. Tight up to 1.5 bars of water pressure. Insulation kit for threaded connection kits For the high and low temperature insulation of the threaded connection kits. Wall-drive-in element For the above-ground laying of the jacket pipe through the wall. For the insertion into the appropriate liner pipes or core drillings. Liner pipe For the reliable sealing into brickwork, concrete and filigree walls. Tight up 2.5 bars of water pressure. 4

5 AEROLINE INOX TERRA WP 100 Technical Data: Heat pump piping system, consisting of: Jacket pipe made of PE-HD; two corrugated stainless steel tubes (feed and return; AEROFLEX insulation of EPDM with black polyolefine-film protection; one electric power installation tube 32; a pull-in aid for manufacturer specific control and sensor cables with plugs up to a diameter of 45 mm; two underground warning tapes (heating line/power cable. The entire system is appropriate for water and water-tyfocor mixtures. The maximum temperature range is of -30 C up to +95 C. Jacket pipe: The double-walled cable liner pipe is made of PE-HD; the ring stiffness is according to DIN 16961, S R24 16,0 kn/m 2 ; minimum bending radius: 42,5 cm (DN 25 and 50 cm (DN 32 / DN 40; Corrugated stainless steel tube: Material no ; maximum working pressure at 95 C DN 25/10 bar, DN 32/6,5 bar, DN 40/4,4 bar; bursting pressure: DN 25 higher 33 bar, DN 32 / DN 40 higher 20 bar. Power installation tube: Power installation tube 32 (inner diam. 22 mm according to DIN EN 50086, for control, sensor and power cables. Insulation AEROFLEX -tube, made of EPDM: Light, flexible, closed-cell synthetic rubber; free of PVC and CFC (according to legal requirements. Fire protection: Euroclasse E according to EN No embrittlement of copper and stainless steel tubes according to DIN 1988 Part 200; dimensions according to DIN EN Reference values of thermal conductivity at +40 C, λ 40 C = 0,038 W/mK, at 0 C, λ 0 C = 0,036 W/mK. Thermal protection: The thermal loss is equal to that of two individually laid pipes with the 100% insulation according to EnEV. The tubes are marked in order to avoid confusion between feed and return. Dimensions: TERRA WP 100 Jacket Pipe Øoutside Liner Pipe Øinside Liquid content in the corrugated stainless steel tube (each 1 m twin tube) Available lengths DN 25 DN mm 200 mm 1,22 l/m 2,20 l/m 5 m 7,5 m 10 m 12 m 14 m 17,5 m 20 m 25 m DN mm 250 mm 5 m 7,5 m 10 m 12 m 3,19 l/m 14 m 17,5 m Insulation thickness feed / return 25 mm / 19 mm 19 mm / 19 mm Pressure Drop: The values of this diagram are based on 1 linear laid meter twin-tube and water at a temperature of 10 C : w = 0,5 m/s : w = 1,0 m/s : w = 1,5 m/s AEROLINE INOX DN 25 PE 25 x 2,3 PE 32 x 2,9 water at 10 C AEROLINE INOX DN 32 PE 40 x 3,7 AEROLINE INOX DN Flow rate [m³/h] Thermal output t = 20 K [kw] Relative pressure drop factor 1 based on different temperatures and mixtures: Medium temperature 5 C 10 C 15 C 20 C 25 C 30 C 35 C 40 C 45 C 50 C Pressure drop factor for water 1,04 1 0,97 0,94 0,91 0,89 0,86 0,83 0,82 0,8 Pressure drop factor for water-tyfocor (L-mix 70/30) 1,44 1,37 1,3 1,24 1,19 1,15 1,1 1,06 1, Source: Tyforop Chemie GmbH 5

6 AEROLINE INOX TERRA WP SPLIT Piping systems for the underground piping of heat pumps placed outside in SPLIT version. Complete system with pre-insulated twin tubes and two integrated power cable installation tubes Connection from the heat pump inside the building to the unit outside Protection against near-surface thermal loss in summer Simple and fast installation Underground piping system for brine/water heat pumps Connection from the brine collector outside to the heat pump inside the house Protection against near-surface thermal loss in the later winter. The ground temperatures near the surface are lower (0 C down to minus degree temperatures) than in (deeper) soil layers, where the absorbers, the basket coil or ground sensor are placed (5 C up to 10 C) Protection of the piping systems against damages System accessories: Jacket pipe sealing kit For the air and water tight seal of the jacket pipe and the fixing of the corrugated stainless steel tubes. Optional accessories please see page 4. AEROLINE Threaded connection kit For the connection to the heat pump and the heating unit. Jacket pipe thermal insulation kit For the high and low temperature insulation of the jacket pipe sealing kit. AEROSEAL Special adhesive For the waterproof sealing of insulation ends. 6

7 AEROLINE INOX TERRA WP SPLIT Technical data: Heat pump piping system, consisting of: Jacket pipe made of PE-HD; two corrugated stainless steel tubes (feed and return; AEROFLEX insulation of EPDM, two electric power installation tubes 25; two underground warning tapes (heating line/power cable. The entire system is appropriate for water and water-tyfocor mixtures with a maximum temperature range of -30 C up to +95 C. Jacket pipe: The double-walled cable liner pipe is made of PE-HD; the ring stiffness is according to DIN 16961, S R24 16,0 kn/m 2 ;minimum bending radius 36 cm (DN 25 and 42,5 cm (DN 32 / DN 40. Corrugated stainless steel tube: Material no ; maximum working pressure at 95 C DN 25/10 bar, DN 32/6,5 bar, DN 40/4,4 bar; bursting pressure: DN 25 higher 33 bar, DN 32 / DN 40 higher 20 bar. Power installation tube: Two Power installation tubes 25 (inner diam.18 mm according to DIN EN 50086, for control, sensor or power cable. Insulation AEROFLEX -tube, made of EPDM: Light, flexible, closed-cell synthetic rubber; free of PVC and CFC (according to legal requirements. Fire protection: Euroclasse E according to EN No embrittlement of copper and stainless steel tubes according to DIN 1988 Part 200; dimensions according to DIN EN Reference values of thermal conductivity at +40 C, λ 40 C = 0,038 W/mK, at 0 C, λ 0 C = 0,036 W/mK. The tubes are marked in order to avoid confusion between feed and return. Dimensions: TERRA WP SPLIT Jacket Pipe Øoutside Liner Pipe Øinside Liquid content in the corrugated stainless steel tube (each 1 m twin tube) Available lengths Insulation thickness feed / return DN 25 DN mm 200 mm 1,22 l/m 2,20 l/m 5 m 7,5 m 10 m 12 m 14 m 17,5 m 20 m 25 m DN mm 200 mm 5 m 7,5 m 10 m 12 m 3,19 l/m 14 m 9 mm / 9 mm 6 mm / 6 mm Pressure Drop: The values of this diagram are based on 1 linear laid meter twin-tube with water-tyfocor (Ethylenglycol) mix (55/45) at a temperature of -20 C : w = 0,5 m/s : w = 1,0 m/s : w = 1,5 m/s AEROLINE INOX DN 25 PE 25 x 2,3 PE 32 x 2,9 AEROLINE INOX DN 32 water-tyfocor mix (55/45) at -20 C PE 40 x 3,7 AEROLINE INOX DN Flow rate [m³/h] Thermal output t = 5 K [kw] Pressure drop factor 1 based on different temperatures and mixtures: Medium temperature -20 C -15 C -10 C -5 C 0 C 5 C 10 C 15 C 20 C 25 C Pressure drop factor for water-tyfocor mix 55/45 1 0,94 0,88 0,83 0,78 0,75 0,71 0,69 0,65 0,64 1 Source: Tyforop Chemie GmbH 7

8 AERORAPID CLASSIC Piping system for the connection of outside air/water heat pumps installed next to the wall and the distribution of brine or water inside the building. Pre-insulated corrugated stainless steel tube Polyolefine-film provides protection against damage during mounting Simple and fast installation Small bending radius Condensation-proof in reversible operation (cooling) Piping system for the connection of brine/water heat pumps and the distribution inside. Pre-insulated corrugated stainless steel tube Polyolefine-film provides protection against damage during mounting Simple and fast installation Small bending radius Condensation-proof in reversible operation (cooling) System accessories: AERORAPID Threaded connection kit For the connection to the heat pump and the heating unit. AERORAPID Threaded coupling For the connection of the heat pump and the heating unit. Optional accessories: Union fittings For all AEROLINE threaded connection kits. AERORAPID mounting brackets For the fixing. Condensation protection: For reversible operation (cooling) we recommend the corresponding accessories for protection against condensation, please see pages 10 and 11. 8

9 Technical Data: Piping system consisting of: corrugated stainless steel tube; AEROFLEX insulation made of EPDM with black polyolefine-film protection, UV resistant. Corrugated stainless steel tube: Material no with a temperature range of -270 C up to +600 C. Maximum working pressure at 200 C DN 20/11 bar, DN 25/10 bar, DN 32/6 bar, DN 40/3,6 bar; bursting pressure: DN 20/DN 25 higher 33 bar, DN 32 / DN 40 higher 20 bar. Minimum bending radius 50 mm (DN 20), 60 mm (DN 25), 55 mm (DN 32 / DN 40); Insulation AEROFLEX -tube, made of EPDM: Light, flexible, closed-cell synthetic rubber; free of PVC and CFC (according to legal requirements). Fire protection: Euroclasse E according to EN No embrittlement of copper and stainless steel tubes according to DIN 1988 Part 200; dimensions according to DIN EN Reference values of thermal conductivity at +40 C, λ 40 C = 0,038 W/mK, at 0 C, λ 0 C = 0,036 W/mK. Dimensions: AERORAPID CLASSIC Pressure drop: Liquid content in the corrugated stainless steel tube (each 1 m twin tube) Available lengths insulation thickness feed / return DN 20 0,41 l/m 13 mm / 25 mm 10 m 25 m 50 m DN 25 0,61 l/m 19 mm DN 32 1,10 l/m 10 m 25 m DN 40 1,60 l/m 25 mm The values of this diagram are based on 1 linear laid meter tube with water at a temperature of 10 C : w = 0,5 m/s : w = 1,0 m/s : w = 1,5 m/s AERORAPID DN 20 PE 20 x 1,9 AERORAPID DN 25 PE 25 x 2, PE 32 x 2,9 PE 40 x 3,7 AERORAPID DN 32 AERORAPID DN Flow rate [m³/h] Thermal output t = 20 K [kw] Pressure drop factor 1 based on different temperatures and mixtures: Pressure drop factor Application Temperature 5 C 10 C 15 C 20 C 25 C 30 C 35 C 40 C 45 C 50 C For water heat pump outside 1,04 1 0,97 0,94 0,91 0,89 0,86 0,83 0,82 0,8 For water tyfocor L-mix 70/30 heat pump outside 1,44 1,37 1,3 1,24 1,19 1,15 1,1 1,06 1,03 1 For water tyfocor L-mix 60/40 solar hybrid heat pump system 1,6 1,5 1,43 1,37 1,3 1,24 1,19 1,15 1,1 1,07 Pressure drop factor For water-tyfocor ethylene glycol mix 55/45 Application heat pump split installation Temperature -20 C -15 C -10 C -5 C 0 C 5 C 10 C 15 C 20 C 25 C 1,99 1,87 1,75 1,66 1,55 1,49 1,42 1,37 1,3 1,27 1 Quelle: Tyforop Chemie GmbH 9

10 AERORAPID CLASSIC Pre-insulated corrugated stainless steel piping for the internal distribution of brine or water for all heat pump systems. Pre-insulated corrugated stainless steel tube Polyolefine-film provides protection against damage during mounting Simple and fast installation Small bending radius Condensation-proof System accessories: AERORAPID Threaded connection kit For the connection to the heat pump and the heating unit. AERORAPID Threaded coupling For the connection of the heat pump and the heating unit. Optional accessories: Union fittings For all AEROLINE threaded connection kits. AERORAPID Mounting brackets For the fixing. Optional accessories for condensation tightness: Insulation kit for threaded connection kits For the high and low temperature insulation of the threaded connection kits. AERORAPID Mounting material Low temperature insulation for condensation protection. AEROSEAL Special adhesive For the waterproof sealing of insulation ends. 10

11 AERORAPID CLASSIC Condensation protection: Maximum relative humidity of the ambiant air in relation to the medium temperature for the AERORAPID Classic DN 20, DN 25, DN 32 and DN 40 for installation according to DIN 4140 (insulation thickness of 19 mm). Tube / medium temperature t R,M Example 1: Example 2: Air / water heat pump in Split placement Tube / medium temperature on a very cold winter day: t R,M = - 25 C Air / water heat pump installed outside or brine / water heat pump in normal operation Tube / medium temperature Air / water heat pump in reversible operation (cooling), brine-/ water heat pump in normal operation: t R,M = + 5 C Ambiant temperature: t L = + 22 C Ambiant temperature: t L = + 22 C Thermal transition coefficient of the ambiance inside (assumptive): α = 5 W/m²K (horizontal installation in a room corner) Summary: Maximum relative ambiant humidity to avoid condensation: t L = + 22 C, φ = 48 % ( T d * = 11 C) Note: In ventilated rooms the relative humidity drops to lower values on cold winter days. * T d = drew point of the ambiance Thermal transition coefficient of the ambiance inside (assumptive): α = 5 W/m²K (horizontal installation in a room corner) Summary: Maximum relative ambiant humidity to avoid condensation: t L = + 22 C, φ = 77 % ( T d * = 18 C) In normal or also in reversible operation (cooling) of air/water heat pumps installed in Split version or air/water and brine / water heat pumps placed outside or next to the wall, there may arise pipe temperatures falling below the dew point (Td) of the ambiant air. Thus the pipes must be installed condensation-proof according to DIN The selected insulation of a thickness of 19 mm in combination with the λ 0 C = 0,033W/mK provides for the indicated interior ambiant conditions a condensation protection in all operation states of the heat pumps (please see examples 1 and 2). In case you are installing piping systems in especially warm and/or humid rooms we will be pleased to check on the required insulation thickness for you. 11

12 Thermal Energy for generations Only with efficient and long-lasting products, a solar thermal turnaround is possible. Human and nature will benefit! nmc Deutschland GmbH Branch Office Ulm Im Lehrer Feld 30 D Ulm T: F: info-ulm@nmc-deutschland.de HP/GB_1.0 04/2017 NMC sa Subject to change.

UPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems

UPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems UPONOR Ltd Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems Reference Page(s) UPONOR Q&E PEX 2 Operating Conditions 2 Pipe Properties 2 Fittings Range 3 Radiator Heating Systems 3 H&C Water

More information

Technical Sheet. Hybrid concealed radiator System Insulated Rubber Pipe

Technical Sheet. Hybrid concealed radiator System Insulated Rubber Pipe System Insulated Rubber Pipe The 3THERMO radiator (concealed or for drywall installation) is adjusted for serial connections. The recommended system installation is SIRK. The radiator should be covered

More information

Flues and chimney systems

Flues and chimney systems Flues and chimney systems Complete systems overview Table of content About us 02 Portfolio overview 03 Timeline 04 Gas flue systems 06 Chimney systems rigid single-wall 08 Chimney systems flexible single-wall

More information

FLEXWELL Safety Pipe. Be on the safe side with this pipe

FLEXWELL Safety Pipe. Be on the safe side with this pipe Be on the safe side with this pipe Innovative and tried and trusted in many applications A B C D General type approval: Z-38.4-253 Dimensions: DN 12 DN 100 Pressure range: 25 bar, PN 25 Temperatures: 10

More information

Corrugated Coated Stainless Steel Hoses for gas use with European Standard EN 15266:2007

Corrugated Coated Stainless Steel Hoses for gas use with European Standard EN 15266:2007 Easy Economic Quick Corrugated Coated Stainless Steel Hoses for gas use with European Standard EN 15266:2007 Scan this QR Code AT&T by your smartphone! To learn how it works: ayvaz.com/qrcode A MEMBER

More information

PRODUCT DATA SHEETS HEAT PUMPS

PRODUCT DATA SHEETS HEAT PUMPS PRODUCT DATA SHEETS HEAT PUMPS HIGH-TEMPERATURE BRINE-TO-WATER HEAT PUMP: UNIERSAL DESIGN - MAX. FLOW TEMPERATURE 70 C HIGHER FLOW TEMPERATURES FOR HEATING AND DOMESTIC HOT WATER PREPARATION LOW-TEMPERATURE

More information

Air Excellent. Straightforward, effective air distribution

Air Excellent. Straightforward, effective air distribution Air Excellent Straightforward, effective air distribution 2 As buildings become better insulated and airtight, purposed- provided ventilation is required to create and sustain a healthy and comfortable

More information

Installation Instructions Solar Controller Kit (Part Number AQ )

Installation Instructions Solar Controller Kit (Part Number AQ ) Installation Instructions Solar Controller Kit (Part Number AQ7014151) This solar controller kit must be installed and serviced by an authorised person. Please leave this guide with the householder. The

More information

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25

Installation and operation instructions Solar stations SolarBloC midi Premium DN 20 SolarBloC maxi Premium DN 25 PAW GmbH & Co. KG Böcklerstr. 11, D-31789 Hameln, Germany Phone: +49-5151-9856-0, Fax: +49-5151-9856-98 E-mail: info@paw.eu, Web: www.paw.eu Installation and operation instructions Solar stations SolarBloC

More information

Uponor Ecoflex Solutions Technical Information. Pre-insulated pipes for water distribution

Uponor Ecoflex Solutions Technical Information. Pre-insulated pipes for water distribution Uponor Ecoflex Solutions Technical Information Pre-insulated pipes for water distribution 0 From heat source......to building Pre-insulated pipe systems connecting you to renewable heat No special tools,

More information

DUOPEX WATER MANUAL mm WM WMKA021044

DUOPEX WATER MANUAL mm WM WMKA021044 DUOPEX WATER MANUAL 32-63mm WM-022149 WMKA021044 The DUOPEX WATER Pipe and Fitting System is designed for 32mm- 63mm potable hot and cold water applications. This revolutionary alternative for the professional

More information

Remote Water Quality System Standard Equipment (supplied by EPI) Remote Water Quality System Optional Equipment (supplied by EPI)

Remote Water Quality System Standard Equipment (supplied by EPI) Remote Water Quality System Optional Equipment (supplied by EPI) Page 1 of 11 Parts List Remote Water Quality System Standard Equipment (supplied by EPI) 20sq ft Skimmer-Filter Remote Water Quality Plumbing Kit Heater-Controller Keypad Control 220V 3/4HP Circulation

More information

EFFECTIVE FROM 1ST JULY 2012 PRODUCT OVERVIEW PRE-INSULATED PIPING SYSTEM

EFFECTIVE FROM 1ST JULY 2012 PRODUCT OVERVIEW PRE-INSULATED PIPING SYSTEM EFFECTIVE FROM 1ST JULY 2012 PRODUCT OVERVIEW PRE-INSULATED PIPING SYSTEM CALPEX a brand of Brugg Pipesystems is a high-quality plastic low temperature system for supplying service water and heat: flexible,

More information

FLEXIBLE CORRUGATED TUBE

FLEXIBLE CORRUGATED TUBE Back To The Natur e S O L A R S Y S T E M SPRINKLER SYSTEM B O I L E R FLEXIBLE CORRUGATED TUBE INSULATED SOLAR HOSES S Y S T E M w w w. k a s. c o m. t r SOLAR SYSTEM System Definition of Corrugated

More information

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers.

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers. ENGIE Refrigeration supplies the right cooling for every process: from efficient chillers and modular re-cooling systems to turnkey solutions such as refrigeration containers or modules. Efficiency, sustainability,

More information

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products 1 821 1821P01 Frost sensors for use on the air side Active capillary tube sensor for measuring the lowest temperature within a range of 0 15 C Operating voltage AC 24 V Signal output DC 0...10 V Use On

More information

SOLAR SYSTEM. We follow the sun.

SOLAR SYSTEM. We follow the sun. SOLAR SYSTEM We follow the sun. www.ayvaz.com AYVAZ SOLAR SYSTEMS COMPLETE SOLAR CONNECTION SET Ayvaz offers a complete set to connect all mechanic components of solar systems to each other and the rest

More information

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological Providing the comfort of instant hot water is the key requirement of any modern hot water system. The Raychem single-pipe system keeps water at the right temperature in a building s water distribution

More information

Special Provision No. 683S28 December 2017

Special Provision No. 683S28 December 2017 FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE - Item No. FIBRE OPTIC COMMUNICATION CABLES, AERIAL ON MESSENGER CABLE (TEMPORARY) - Item No. Special Provision No. 683S28 December 2017 1. SCOPE

More information

DUOPEX WATER MANUAL mm

DUOPEX WATER MANUAL mm DUOPEX WATER MANUAL 32-63mm The DUOPEX WATER Pipe and Fitting System is designed for 32mm- 63mm potable hot and cold water applications. This revolutionary alternative for the professional plumber, makes

More information

Documentation. Parallel Heating Cable. Type: ELP

Documentation. Parallel Heating Cable. Type: ELP Documentation Parallel Heating Cable Type: ELP 05.01.2018 K. Folkerts Content 1. Data sheet 2. Installation instructions 3. Declarations of conformity 05.01.2018 K. Folkerts 1 05.01.2018 K. Folkerts Constant

More information

First Trace Heating Product Details

First Trace Heating Product Details First Trace Heating Product Details and specifying guide Contents 2 4 6 9 9 10 Refrigeration Safe Trace Product Diagrams 11 Components www.first-traceheating.co.uk Introduction Specification Maximum Exposure

More information

CIRCO 6 Solar Circulation Unit

CIRCO 6 Solar Circulation Unit TECHNICAL INFORMATION / INSTALLATION INSTRUCTIONS CIRCO Solar Circulation Unit CIRCO Solar Circulation Unit in combination with the intelligent SUNGO controllers, it is the safe and reliable heart of a

More information

ELECTRIC HEATING THERMOSYSTEM

ELECTRIC HEATING THERMOSYSTEM ELECTRIC RADIANT MAT 8200E INSTALLATION AND USE MANUAL heating passion ELECTRIC HEATING THERMOSYSTEM WARNING: For the guarantee to be valid, the product must be installed and handled as indicated in this

More information

Geothermal Heat Pump Systems

Geothermal Heat Pump Systems Geothermal Heat Pump Systems 1 Earth is a Vast Solar Collector 2 U.S. Underground Temperatures 3 The Earth is a Source of Heat in Winter Outdoor air temperature: 5 F 72 F Geothermal heat pumps transfer

More information

Installation Manual. Frost Protection Cable. Warmup Ireland Web: Telephone:

Installation Manual. Frost Protection Cable. Warmup Ireland Web:     Telephone: Installation Manual Frost Protection Cable Warmup Ireland Web: www.warmup.ie Email: ie@warmup.com Telephone: 1 800 937 429 TECHNICAL HELPLINE 0845 345 2288 IMPORTANT Read this manual before attempting

More information

Standard Installation Manual

Standard Installation Manual Standard Installation Manual READ THIS MANUAL BEFORE INSTALLATION Caution If you plan to install your solar heater system on a roof be sure you are experienced in working on roofs and have the proper safety

More information

BLAUDIECK DS Steam- and hot water hose

BLAUDIECK DS Steam- and hot water hose BLAUDIECK DS Steam- and hot water hose Kennzeichnung: Red-white logos BLAUDIECK on blue cover The Blaudieck DS steam- and hot water hose has been developed for reliable cleaning purposes in various industrial

More information

Multilux 4-Eclipse-Set

Multilux 4-Eclipse-Set Multilux -Eclipse-Set Design-Edition with two-point connection, angle and straight type, for R / and connection, with automatic flow limitation IMI HEIMEIER / Design-Edition / Multilux -Eclipse-Set Multilux

More information

Carbon Film Installation Instructions

Carbon Film Installation Instructions Contents Page 2 Page 3 Page 4 Page 5 Page 8 Product Overview Pre-Installation & Electrical Provision Depron Underlay Installation Carbon Film Installation - Under Wood/Laminate Flooring Notes & Trouble

More information

Gasketed and brazed plate heat exchangers

Gasketed and brazed plate heat exchangers Gasketed and brazed plate heat exchangers Contents Gasketed plate heat exchangers Options Brazed plate heat exchangers Options 14 22 30 32 www.fiorinigroup.it 11 Gasketed and brazed plate heat exchangers

More information

Xpert HD Xpert HD 7140, ,

Xpert HD Xpert HD 7140, , Xpert HD 7140 Cold-water pressure washer for daily commercial use. With its compact dimensions, robust construction and greatest possible manoeuvrability, this unit is a credit to the compact class. TECHNICAL

More information

Installing Underfloor Heating Film. 1. Layout of electric underfloor heating systems

Installing Underfloor Heating Film. 1. Layout of electric underfloor heating systems Read through this entire manual before starting installation. May be installed under laminate, engineered wood or approved hardwood floors. See flooring manufacturer s specifications and instructions.

More information

General System Layout Sketch

General System Layout Sketch General System Layout Sketch EZ-37 Solar Panels PV panel Glycol Fill Valve Expansion Tank ` 1 Introduction This document describes how to install a Heliatos GH type solar water heating system. These systems

More information

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW:

Tank systems. Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW: Tank systems Layered tank Solar layered tank Hygienic layered tank Modular layered tank Hot water tank NEW: NEOPOR AND FLEECE INSULATION SENSOR TERMINAL STRIP ADJUSTABLE FEET www.froeling.com Energy management

More information

In cooperation with. sustainable energy solutions

In cooperation with. sustainable energy solutions EN In cooperation with sustainable energy solutions 2 Index Page 3 Index Page 4 Why accumulator tank? Page 5 Why Laddotank? Page 6-7 Buffer tank, PUFFER (500-2 000) Page 8-9 Buffer tank, PUFFER COMPACT

More information

Flues and chimney systems

Flues and chimney systems Flues and chimney systems Complete systems overview CLV systems concentric Description 4 4 1 3 The concentric CLV system is a collective chimney system especially for apartment buildings. It brings combustion

More information

Ready-to-Use Heat Tracing Solutions for Laboratory Applications. innovations in heat tracing

Ready-to-Use Heat Tracing Solutions for Laboratory Applications. innovations in heat tracing Ready-to-Use Heat Tracing Solutions for Laboratory Applications innovations in heat tracing eltherm GmbH Solutions with Electric Heat Tracing Systems eltherm GmbH is an internationally operating engineering

More information

Quality Heat Exchangers

Quality Heat Exchangers Quality Heat Exchangers Brazed Plate Heat Exchangers Series TPL With partnership into the future FUNKE is a leader in the development and production of quality heat exchangers with a heat transfer area

More information

VIESMANN VITOCAL 300-G Brine/water and water/water heat pump Single and two-stage, from 21 kw

VIESMANN VITOCAL 300-G Brine/water and water/water heat pump Single and two-stage, from 21 kw VIESMANN VITOCAL 00-G Brine/water and water/water heat pump Single and two-stage, from 21 kw Technical guide Heat pump with electric drive for DHW and central heating in mono-mode or dual mode heating

More information

HD 5/11 C Plus. Automatic pressure cut-off. Pump technology

HD 5/11 C Plus. Automatic pressure cut-off. Pump technology HD 5/11 C Plus Compact cold-water high pressure cleaner. With its compact dimensions, robust construction and greatest possible manoeuvrability, this unit is a credit to the compact class. 1 Automatic

More information

Chemical Pumps Vertical Chemical Pump Type TNP

Chemical Pumps Vertical Chemical Pump Type TNP Chemical Pumps Vertical Chemical Pump Type TNP In PP / PE-UHMW / PVDF Vertical setting depths up to 00 mm Applications Type TNP vertical chemical pumps are specifically designed to handle acids, alkalis

More information

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES CORFLEX TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES INDEX Instrumentation Cables - Pairs and Triads (0V*)... 2 - The Original MC-HL Technology In 1958 Canada Wire and Cable, which s now part of Nexans,

More information

Simple. Smart. Solutions. ROOM PACK Z2105/239/0812. Step by Step Installation Guide

Simple. Smart. Solutions. ROOM PACK Z2105/239/0812. Step by Step Installation Guide Simple. Smart. Solutions. ROOM PACK Z2105/239/0812 Step by Step Installation Guide 1. Room Pack Overview 2. Temperature Settings 3. Operation 4. Wiring 5. Installing Your Room Pack Before you get started

More information

Gas wall system and combination boilers. Why Vaillant? For more technology and experience. atmotec plus turbotec plus atmotec pro turbotec pro

Gas wall system and combination boilers. Why Vaillant? For more technology and experience. atmotec plus turbotec plus atmotec pro turbotec pro Gas wall system and combination boilers Why Vaillant? For more technology and experience. atmotec plus turbotec plus atmotec pro turbotec pro High comfort - with German technology. Our atmotec and turbotec

More information

templine electrically heated hoses with with system system options options

templine electrically heated hoses with with system system options options templine electrically heated hoses with with system system options options Economical Flexible Optimum Ready for use Reduce your energy by up to 30 % in comparison with conventional systems Extremely bendable

More information

Danfoss Air Heating Surfaces

Danfoss Air Heating Surfaces MAKING MODERN LIVING POSSIBLE Installation Guide www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The English

More information

Leica EM CPD030 Order List Version 10/2008

Leica EM CPD030 Order List Version 10/2008 Leica EM CPD030 Order List Version 10/2008 16BUG03500 16BUG03501 LEICA EM CPD030 Critical Point Dryer 230 240 V / 50 60 Hz 115 V / 60Hz - Solvent resistant metal housing - Operation panel with integrated

More information

DUCTING & VACUUM HOSE

DUCTING & VACUUM HOSE DUCTING & VACUUM HOSE 11 VACUUM HOSE An extremely flexible and lightweight hose for vacuuming wet or dry materials in shops and car washes. The hose is crush-proof because it returns to its original shape

More information

DOMOTHERM CLASSIC TWIN/S MAT

DOMOTHERM CLASSIC TWIN/S MAT Floor warming products 2013 V 10.12.2012 DOMOTHERM CLASSIC TWIN/S MAT An ideal solution for the whole house Ultra thin cable (2mm) Energy efficient Easy to install Domotherm Twin/s can be installed under:

More information

General System Layout Sketch

General System Layout Sketch General System Layout Sketch SW-38 Solar Panel(s) Hot Water Cold Water PV panel Glycol RV Water Heater WITH built in Heat Exchanger Water Ports ` Glycol Fill Valve 1 Pump Solar Powered Expansion Tank Glycol

More information

DIN EN , DIN EN , DIN EN , DIN EN

DIN EN , DIN EN , DIN EN , DIN EN Test Report issued under the responsibility of: TEST REPORT EHPA-DACH Testing Regulation Supplemental requirements for granting the international quality label for heat pumps Testing of Air/Water Heat

More information

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side s Frost detectors for use on the air side QAF63.2-J QAF63.6-J Active capillary tube sensor for acquiring the lowest temperature within a range of 0 15 C Operating voltage AC 24 V Signal output DC 0...10

More information

VIBRA SCHULTHEIS. Vibrating Spiral Conveyors.

VIBRA SCHULTHEIS. Vibrating Spiral Conveyors. VIBRA SCHULTHEIS Vibrating Spiral Conveyors www.vibra-schultheis.com P 134 E VIBRA MASCHINENFABRIK SCHULTHEIS GmbH & Co. Im Großen Ahl 41-51 D-63075 Offenbach am Main Phone +49 (0)69/ 86 00 03-0 Fax +49

More information

LUNOS Domestic Ventilation Systems With Heat Recovery. Innovations for New Buildings and Redevelopment. e2 + e go

LUNOS Domestic Ventilation Systems With Heat Recovery. Innovations for New Buildings and Redevelopment. e2 + e go LUNOS Domestic Ventilation Systems With Heat Recovery Innovations for New Buildings and Redevelopment e2 + e go Domestic Ventilation e² and ego in a de-centralized system 2 3 System & Planning Ventilation

More information

Cold water compact class HD 5/12 C

Cold water compact class HD 5/12 C Cold water compact class HD 5/12 C Convenient, mobile, versatile: the HD 5/12 C cold water high-pressure cleaner for vertical and horizontal operation. With accessory storage, brass cylinder head and automatic

More information

FLEXIBLE METAL - BENDING THE RULES OF PLUMBING CONNECT WITH CONFIDENCE SEE OUR NEW EXTENDED RANGE OF VALVES -

FLEXIBLE METAL - BENDING THE RULES OF PLUMBING CONNECT WITH CONFIDENCE SEE OUR NEW EXTENDED RANGE OF VALVES - FLEXIBLE METAL - BENDING THE RULES OF PLUMBING CONNECT WITH CONFIDENCE SEE OUR NEW EXTENDED RANGE OF VALVES - AVAILABLE FROM JULY 2014 THE TECTITE FLEXIBLE METAL SYSTEM Every customer relies on you to

More information

Principles of Cold Insulation

Principles of Cold Insulation Principles of Cold Insulation FEDERATION EUROPEENNE DES SYNDICATS D ENTREPRISES D ISOLATION EUROPEAN FEDERATION OF ASSOCIATIONS OF INSULATION CONTRACTORS May 1997 www.fesi.eu Principles of cold insulation

More information

HEATING. COOLING. COMFORT. For a cosy home.

HEATING. COOLING. COMFORT. For a cosy home. HEATING. COOLING. COMFORT. For a cosy home. www.variotherm.com VIDEO VIDEO THE VARIOTHERM WORLD AMAZING COMFORT. WITH ATTRACTIVE SAVINGS. Variotherm s floor heating systems, skirting heating systems, trench

More information

HD 7/11-4 Cage Classic

HD 7/11-4 Cage Classic HD 7/11-4 Cage Classic Long service intervals and high-quality components such as the crankshaft pump with ceramic piston are among the many strengths of the HD 7/11-4 Cage Classic single-phase high-pressure

More information

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation Standard C Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Standard C Standard C The Standard C thermostatic

More information

LOW STATIC HYDRONIC DUCTED UNIT

LOW STATIC HYDRONIC DUCTED UNIT LOW STATIC HYDRONIC DUCTED UNIT PDWA-~AC SERIES PDWA(4R)-~-V-MEDC PDWA(4R)-~-V-MEEU PDWA(R)-~-V PDWA(R+1)-~-P Model cooling capacity( KW) at Medium Speed cooling capacity (KW) at Medium Speed cooling capacity

More information

Mikrotherm. Manual Radiator Valves With presetting

Mikrotherm. Manual Radiator Valves With presetting Mikrotherm Manual Radiator Valves With presetting IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Mikrotherm Mikrotherm The Mikrotherm manual radiator valve is used in warm water pump heating systems,

More information

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation mfh systems modern floor heating AirUnit Decentralised domestic ventilation Installation instructions List of contents, Installation instructions Page 1. General information... 03 2. Function / planning

More information

TECHNICAL SPECIFICATIONS AND INSTALLATION

TECHNICAL SPECIFICATIONS AND INSTALLATION TECHNICAL SPECIFICATIONS AND INSTALLATION CEILING-MOUNTED HEATER ENERGO EcoEvo Vierkantrohr = rectangular pipe Wärmedämmung = heat insulation Tragrohr = support pipe Seitenpaneel = side panel Mittelpaneel

More information

Solar Thermal Energy

Solar Thermal Energy Solar Thermal Energy INDEX Residential Applications Flat Plate Solar Collectors... 5 SOL 200 and SOL 200 H... 7 Mediterráneo 200... 8 Mediterráneo SLIM 200... 9 Hydraulic fittings and mounting systems...

More information

Hot water super class HDS 12/18 4S *AU

Hot water super class HDS 12/18 4S *AU Hot water super class HDS 12/18 4S *AU Our new medium and super class hot water high-pressure cleaners not only clean exceptionally well, they are also extremely rugged and simple to operate. The new ECO

More information

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold Dynalux Floor Heating Manifolds Underfl oor heating circuit manifold IMI HEIMEIER / Floor Heating Control / Dynalux Dynalux Dynalux adjusts the flow rate in the individual heating circuits directly in

More information

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES INDEX Corflex MC-HL Instrumentation - Pairs and Triads (0V*)... 1 - CORFLEX Cables

More information

IMI Heimeier Kit Hydroca ble

IMI Heimeier Kit Hydroca ble IMI Heimeier Kit Hydroca ble Thermostatic valves with radiator connection systems Thermostatic valve and lockshield with tube-bend for the installation as angle form or axial form with press- or sliding

More information

Heating with natural heat

Heating with natural heat Heating with natural heat 2/3 Heat pumps: Heating and cooling with natural energy The purpose of this brochure is to give you detailed information about one of the most futureproof and environmentally

More information

REMKO HYBRID HEAT PUMPS

REMKO HYBRID HEAT PUMPS REMKO HYBRID HEAT PUMPS Switch over to more efficiency even in old buildings HBW series 1-2014 Quality with systems THE HYBRID TECHNOLOGY Two technologies combined into one innovation "Hybrid comes from

More information

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS RAE 1352 F.K + MV AIR R-407C FC Series RAE... F.K Cooling capacity from 77 to 289 kw - 2 circuits The air cooled chillers of RAE... F.K series, are designed for outdoor installation and are particularly

More information

TECHNICAL CERTIFICATE USER MANUAL THERMOSTAT TP years warranty

TECHNICAL CERTIFICATE USER MANUAL THERMOSTAT TP years warranty TECHNICAL CERTIFICATE USER MANUAL THERMOSTAT TP510 3 years warranty TABLE OF CONTENT Application 4 Controls and indication 4 Adjustment and operation 5 Switch on / switch off the thermostat 5 Adjustment

More information

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

MEDIUM, LOW AND CONTROL VOLTAGE CABLES Related Sections U-M Design Guideline Sections: 260800 - Electrical Acceptance Tests Products Medium Voltage Primary Cables Primary power distribution cable shall be single conductor stranded copper, with

More information

TS RD 7761 RD, 7761 RD

TS RD 7761 RD, 7761 RD 1/2 HERZ Calis TS RD three way valve HERZ Calis TS RD 100% three-way valve for heating and cooling Datasheet for 1 7761 RD, Issue 0716 Dimensions in mm Order number Dimension R A B C kvs dp (bar) maximum

More information

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

Geolo THE GROUND SOURCE HEAT PUMP PLUSES Geolo THE GROUND SOURCE HEAT PUMP PLUSES RENEWABLE TECHNOLOGIES Geolo is able to exploit the Energy present in the water and underground thanks to the geothermal exchangers. Soil and water absorb the solar

More information

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup. SECTION 23 70 00- CENTRAL HVAC EQUIPMENT PART 1: GENERAL 1.1 PURPOSE: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

FLOOR WARMING PRODUCTS. For more ALL PICTURES & GRAPHICS ARE FOR ILLUSTRATION ONLY

FLOOR WARMING PRODUCTS. For more ALL PICTURES & GRAPHICS ARE FOR ILLUSTRATION ONLY 3102 A very warm welcome to The Decora Group the management and holding company for Domoteck and Climateck Industries. Focusing on making modern living comfortable, the Decora group has developed some

More information

SECTION (15820) - AIR DUCT ACCESSORIES

SECTION (15820) - AIR DUCT ACCESSORIES PART 1 GENERAL 1.01 SUMMARY A. Section includes: SECTION 23 33 00 (15820) - AIR DUCT ACCESSORIES 1. Manual-Volume Dampers 2. Fire Dampers 3. Turning Vanes 4. Duct-Mounted Access Doors 5. Flexible Connectors

More information

Duct Temperature Sensors

Duct Temperature Sensors 1 762 1761P03 1762P01 Mounting flange AQM630 QAM21 Symaro Duct Temperature Sensors QAM2161040 QAM2171040 Active sensors for acquiring the air temperature in air ducts AC 24 V or DC 13535 V Signal output

More information

www.yorkshirecopper.com Kuterlex Plastic Coated Copper to BS EN 13349/1057 BS EN 1057 Kuterlex is copper tube coated with a seamless plastic cover which protects the copper tube against aggressive materials.

More information

1 What is the name of the tool shown in the diagram? Basin wrench Footprint wrench Stilson wrench Torque wrench.

1 What is the name of the tool shown in the diagram? Basin wrench Footprint wrench Stilson wrench Torque wrench. 36 Exam Success Plumbing and Heating 6189-11 and 6189-21 Sample test The sample test below is for paper 6189-005, Understand and carry out site preparation, and pipework fabrication techniques for domestic

More information

Band Heaters. Rectangular Band Heaters, Strip, Ring and Flat Heaters. Contact Accessories, Connection Boxes, Clamping Devices

Band Heaters. Rectangular Band Heaters, Strip, Ring and Flat Heaters. Contact Accessories, Connection Boxes, Clamping Devices Band Heaters Mica Insulated Band Heaters (HM) Ceramic Insulated Band Heaters (KHM) Rectangular Band Heaters, Strip, Ring and Flat Heaters Protection Housings (WSM) Cast Heaters, Band, Flat or Custom Insulating

More information

Mounting and Operating Instructions EB 2231 EN

Mounting and Operating Instructions EB 2231 EN Self-operated Regulators Thermostats Type 223 and Type 2232 Bulb Sensors Type 2233, Type 2234, and Type 2235 Air Sensors Type 223 with bulb sensor Type 2232 with bulb sensor (separate) Type 2233 with air

More information

Richard Hiles ClimateMaster

Richard Hiles ClimateMaster Minnesota Geothermal Heat Pump Association 2012 Properly Sizing Ground Source Heat Pump Systems Richard Hiles ClimateMaster Objective Properly Size and Select GSHP System for Low Operating Costs And Proper

More information

CERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours.

CERAMIC PUMPS FGP. Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours. CERAMIC PUMPS FGP Horizontal Liquid Ring Pumps Solid and gas-tight silicate ceramic for gases and vapours. FGP THE SOPHISTICATED PUMP CONCEPT If you want to solve demanding pumping tasks in the industry

More information

Zeparo Cyclone. Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology

Zeparo Cyclone. Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology Zeparo Cyclone Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology IMI PNEUMATEX / Air Vents, Dirt Separators and Degassing / Zeparo Cyclone Zeparo Cyclone Comprehensive

More information

INSTALLATION AND SERVICING

INSTALLATION AND SERVICING AND SERVICING SOLAR THERMAL For users guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification

More information

CLEAN ROOM MEDICAL LUMINAIRE

CLEAN ROOM MEDICAL LUMINAIRE CLEAN ROOM MEDICAL LUMINAIRE High protection degree Energy efficiency Longevity Comfort BUCK GmbH Lehrer-Tal-Weg 40 89075 Ulm, Germany Tel: +49-731-950 32 330 Fax +49-731-950 32 332 e-mail: office@bucklicht.de

More information

Vacuum drying oven for non-flammable solvents

Vacuum drying oven for non-flammable solvents VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.

More information

Viega Press systems. Always the right connection.

Viega Press systems. Always the right connection. Viega Press systems. Always the right connection. 2 Viega a better Idea! Family tradition The name Viega stands for a family company which set high standards from the word go. Product quality, client proximity,

More information

sustainable energy solutions

sustainable energy solutions EN sustainable energy solutions 2 Index Page 3 Index Page 4 Why accumulator tank? Page 5 Why Laddotank? Page 6-7 Buffer tank, PUFFER (500-2 000) Page 8-9 Buffer tank, PUFFER COMPACT (2 500-8 000) Page

More information

Wood gasification process...3. Wood as a fuel...3. Boiler construction - its elements...4

Wood gasification process...3. Wood as a fuel...3. Boiler construction - its elements...4 Wood gasification process... Wood as a fuel... Boiler construction - its elements...4 Boiler construction - materials...4 EKO advantages...4 Boiler construction - schematics... Boiler dimensions... Boiler

More information

Thermotech underfloor heating

Thermotech underfloor heating Thermotech underfloor heating Assortment and pricelist 2010 Copyright: Thermotech Scandinavia AB 2009 Cover photo: Michael Engman Graphic design: Ulrika Mattisson Other image material: Michael Engman,

More information

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No. Special Provision No. 683S01 December 2017 1. SCOPE This Special Provision covers

More information

EXPERTS PREFER PROVEN PRODUCTS

EXPERTS PREFER PROVEN PRODUCTS POLO-KAL BUILDING SOLUTIONS EXPERTS PREFER PROVEN PRODUCTS POLO-KAL THE ORIGINAL. Since 1957, we have repeatedly set the top quality standard for plastic above-ground drainage pipe systems with our premium

More information

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual M2i-VAM-2 Cast iron condensing boiler 200i Vent/air manual Installation instructions for vent and air piping Also read and follow: 200i Boiler manual 200i Control manual This manual is intended only for

More information

Always make sure to check the heating film before, during, and after installation of the floor covering.

Always make sure to check the heating film before, during, and after installation of the floor covering. Installation of floor heating film for ceramic tiles, granite and other stone or composite flooring Read through this entire manual before starting installation. All electrical connections must be made

More information

Designed by TD lighting Solutions in Turkey, Powered by Nichia LEDs from Japan

Designed by TD lighting Solutions in Turkey, Powered by Nichia LEDs from Japan Pairo Tape Light Solutions Page Number 1 of 10 Product benefits Very Efficient Linear Lighting Design Possible >128lm/W No Color changing at the end of the Strip Same color and light output consistence

More information