PRODUCT CATALOG SURFACE PUMPS RESIDENTIAL & LIGHT COMMERCIAL. franklinwater.com

Size: px
Start display at page:

Download "PRODUCT CATALOG SURFACE PUMPS RESIDENTIAL & LIGHT COMMERCIAL. franklinwater.com"

Transcription

1 PRODUCT CATALOG SURFACE PUMPS RESIDENTIAL & LIGHT COMMERCIAL franklinwater.com

2

3 PACKAGED SYSTEMS Inline Controls... 2 FLW...3 SWC & SWP...4 ADJ...5 CTL 6 Inline Pressure Boosting... 7 Inline Inline Constant Pressure...10 Inline For the most up-to-date product information, visit franklinwater.com.

4 INLINE CONTROLS Franklin Electric s new Inline Controls include five pump starting and control devices that pair with a variety of submersible or surface pump up to 20 amps (or approximately 3 hp) to provide or boost the system s overall water pressure and in many cases, without the need of an additional bladder tank. Depending on application requirements and selected model, the product family offers various forms of system protection, including dry run, dead head pumping, over amperage, locked system, and over pressurization. They also offer two unique features that ensure the system remains functional and hassle free, including: a daily motor rotation start designed to energize the motor at least once every 24 hours to prevent system locking, and a unique automatic restart feature eliminating the need to manually restart the pump in the case of an unexpected trip or fault. FEATURES BY MODEL FLW SWC SWP ADJ CTL CLASSIFIED BY UL TO NSF/ANSI 372 Model Description Flow Based Pump Run Dry Protection Backup Activation Switch and Tank Gauge Backup Activation Regulation Low-Pressure Replaces Pressure Includes Pressure Adjustable Low-Pressure Max. Pressure Suction Lift Activation Inline FLW InlineSWC InlineSWP InlineADJ 115 V InlineADJ 230 V InlineCTL NOTE: Proper pump selection is essential for use with the Inline FLW, SWC, SWP, and ADJ as pump shut-off pressure will be realized within the system prior to shut down. If the pump size can not be reduced, select the Inline CTL with built-in pressure reducing valve. TECHNICAL SPECIFICATIONS Model Description Motor Size Voltage Max. Current Max. Temp. Min. Flow (GPM) Thread Size InlineFLW up to 1.5 hp up to 1.1 kw 115/ A 150 F " MNPT InlineSWC up to 2 hp up to 1.5 kw 115/ A 150 F " MNPT InlineSWP up to 3 hp up to 2.2 kw 115/ A 150 F /4" MNPT InlineADJ 115 V up to 0.75 hp up to 0.55 kw A 150 F " MNPT InlineADJ 230 V up to 2 hp up to 1.5 kw A 150 F " MNPT InlineCTL up to 3 hp up to 2.2 kw 115/ A 150 F /4" MNPT 2

5 INLINE CONTROLS - FLW Use with a pressurized water supply such as an elevated tank or a municipal/utility source. The Inline Control FLW is a smart flow activated pump start control, designed for use in conjunction with a pump where starting and stopping the system based on water usage is desired. FEATURES With flow of 0.15 gpm or greater the pump is activated to ensure continuous operation during water demand cycles Can be wired for 115V or 230V with no internal settings or wiring changes required Protects pump from conditions of dry run and pumping against a closed discharge (dead-head) by powering off the system when water flow stops If the pump remains idle for 24 consecutive hours, the device will carry out an autorun feature to keep the system free of debris and clogs Replaces the need for an external pressure tank and differential pressure switch Flow Based Pump Run Dry Low-Pressure Replaces Pressure Includes Pressure Adjustable Low-Pressure Max. Pressure Model Description Suction Lift Activation Protection Backup Activation Switch and Tank Gauge Backup Activation Regulation Inline FLW NOTE: Proper pump selection is essential for use with the Inline FLW as pump shut-off pressure will be realized within the system prior to shut down. If the pump size cannot be reduced to a lower output performance within the systems pressure limits, select the Inline CTL with built-in pressure reducing valve. ORDERING INFORMATION Model Description Order No. Model No. Motor Size Voltage Max. Current Max. Temp. Thread Size InlineFLW FIL-FLW hp ( kw) 115/ A 150 F 1" MNPT 3

6 INLINE CONTROLS - SWC & SWP Use with a pressurized water supply or suction lift installation for municipal and well supply sources. The Inline Control SWC and SWP are flow activated smart pump start controls, designed for use in conjunction with a pump where starting and stopping the system based on water usage is desired. FEATURES With flow of 0.25 gpm or greater the pump is activated to ensure continuous operation during water demand cycles When flow is less than 0.25 gpm, the pump starts at a minimum pressure of 22 psi If the pump starts due to low system pressure, with no additional demand, the Inline SWC and SWP will only run the system to rebuild pressure Can be wired for 115V or 230V with no internal settings or wiring changes required Includes a convenient built-in check valve Protects pump from conditions of dry run, overcurrent, and pumping against a closed discharge (dead-head) by powering off the system when water flow stops If the pump remains idle for 24 consecutive hours, the device will carry out an autorun feature to keep the system free of debris and clogs The system will auto-rest up to 10 times in a 24 hour period if no water is detected, to protect the pump Replaces the need for an external pressure tank and differential pressure switch SWC SWP Model Description Flow Based Pump Run Dry Low Pressure Replaces Pressure Includes Pressure Adjustable Low-Pressure Max. Pressure Suction Lift Activation Protection Backup Activation Switch and Tank Gauge Backup Activation Regulation InlineSWC InlineSWP NOTE: Proper pump selection is essential for use with the Inline SWC and SWP as pump shut-off pressure will be realized within the system prior to stopping the pump. If the pump size cannot be reduced to a lower output performance within the systems pressure limits, select the Inline CTL with built-in pressure reducing valve. ORDERING INFORMATION Model Description Order No. Model No. Motor Size Voltage Max. Current Max. Temp. Thread Size InlineSWC FIL-SWC hp ( kw) 115/ A 150 F 1" MNPT InlineSWP FIL-SWP hp ( kw) 115/ A 150 F 1 1/4" MNPT FIL-SWC16 FIL-SWC20 4

7 INLINE CONTROLS - ADJ Use with a pressurized water supply or suction lift installation for municipal and well supply sources. The Inline Control ADJ is a smart flow activated pump start control, designed for use in conjunction with a pump where starting and stopping the system based on water usage is desired. With water flow being the primary system start command, the unit provides a backup low pressure cut-in point where the pump will start to repressurize the system. The InlineADJ allows this low pressure cut to be adjusted to 22, 29, or 36 PSI to ensure the system will still reach the desired shut-off pressure. FEATURES With flow of 0.25 gpm or greater the pump is activated to ensure continuous operation during water demand cycles When flow is less than 025 gpm, the user may select between three adjustable cut-in points for a minimum system pressure of 22, 29, or 36 psi If the pump starts due to low system pressure, with no additional demand, the Inline ADJ will only run the system to rebuild pressure Separate models for 115V or 230V with no internal settings or wiring changes required Includes a convenient built-in check valve Protects pump from conditions of dry run, overcurrent, and pumping against a closed discharge (dead-head) by powering off the system when water flow stops If the pump remains idle for 24 consecutive hours, the device will carry out an autorun feature to keep the system free of debris and clogs. The system will auto-rest up to 10 times in a 24 hour period if no water is detected, to protect the pump Replaces the need for an external pressure tank and differential pressure switch Model Description Flow Based Pump Run Dry Low-Pressure Replaces Pressure Includes Pressure Adjustable Low-Pressure Max. Pressure Suction Lift Activation Protection Backup Activation Switch and Tank Gauge Backup Activation Regulation InlineADJ 115 V InlineADJ 230 V NOTE: Proper pump selection is essential for use with the Inline ADJ as pump shut-off pressure will be realized within the system prior to shut down. If the pump size cannot be reduced to a lower output performance within the systems pressure limits, select the Inline CTL with built-in pressure reducing valve. ORDERING INFORMATION Model Description Order No. Model No. Motor Size Voltage Max. Current Max. Temp. Thread Size InlineADJ 115 V FIL-ADJ16-1G 0.75 hp (0.55 kw) A 150 F 1" MNPT InlineADJ 230 V FIL-ADJ16-2G 2hp (1.5 kw) A 150 F 1" MNPT FIL-ADJ16-1G and FIL-ADJ16-2G 5

8 INLINE CONTROLS - CTL Use with a pressurized water supply or suction lift installation for municipal and well supply sources. The Inline Control CTL is a smart flow activated pump start control, designed for use in conjunction with a pump where starting and stopping the system based on water usage is desired. By turning the dial on the back of the unit the maximum system pressure may be regulated within the pump s output range to match the application s need. FEATURES With flow of 0.25 gpm or greater the pump is activated to ensure continuous operation during water demand cycles Built-in pressure reducing valve to allow for customization of maximum output pressure Can be wired for 115V or 230V with no internal settings or wiring changes required If the pump starts due to low system pressure, with no additional demand, the Inline SWC and SWP will only run the system to rebuild pressure Protects pump from conditions of dry run, over pressure, and pumping against a closed discharge (dead-head) by powering off the system when water flow stops If the pump remains idle for 24 consecutive hours, the device will carry out an autorun feature to keep the system free of debris and clogs Replaces the need for an external pressure tank and differential pressure switch Includes a convenient built-in check valve Adjust knob to set the pump s maximum output pressure at a desired regulation point to prevent system over-pressurization Flow Based Pump Run Dry Low-Pressure Replaces Pressure Includes Pressure Adjustable Low-Pressure Max. Pressure Model Description Suction Lift Activation Protection Backup Activation Switch and Tank Gauge Backup Activation Regulation InlineCTL ORDERING INFORMATION Model Description Order No. Model No. Motor Size Voltage Max. Current Max. Temp. Thread Size InlineCTL FIL-CTL hp ( kw) 115/ A 150 F 1 1/4" MNPT FIL-CTL20 6

9 INLINE PRESSURE BOOSTING - INLINE 400 FEATURES Utilizes proven Franklin Electric pump and motor to create the most trustworthy product on the market Simple flow-based controls mean you get the pressure every time you need it Protective cap comes standard for outdoor use (for vertical applications only) Whisper-quiet operation Installs vertically or horizontally 1-1/4" NPT inlet and outlet 115 V and 230 V models available Plug-in electrical cord connected unit Protective features: Over/Under voltage protection, dry run, and over temperature Product power rating: 1/3 hp, kw Maximum Water Temperature: 120 F/49 C APPLICATIONS City water pressure boosting Pressurize water from cistern tank Re-pressurizing after filtration Irrigation system boosting ORDERING INFORMATION Model Description Order No. HP Input Voltage Inline V /3 115 V Inline V w/ tank 115 V /3 115 V Inline V /3 230 V Inline V w/ tank 230 V /3 230 V REPLACEMENT PARTS & KITS Model Description Order No. Tank Wrench Inlet Pressure Switch Outlet Pressure Switch Replacement Tank Replacement Cover Replacement Base Motor Capacitor V Motor Capacitor V Power Cord V Power Cord V Flow Piston Kit Tank O-ring Outdoor Protective Cap Kit Expansion Tank, 2 Liter, 1" MNPT Connection Protective Cap 7

10 INLINE PRESSURE BOOSTING - INLINE 400 PERFORMANCE METERS FEET PSI INCREMENTAL PRESSURE INCREASE GPM L/MIN M 3 /H FLOW 8

11 8.86 [225] 1.77 [45] [146] [90] INLINE PRESSURE BOOSTING - INLINE [35] DIMENSIONS 0.98 [25] 8.86 [225] 4.61 [117] [444] [752] 9.21 [234] 7.64 [194] 8.86 [225] 3.74 [95] 3.74 [95] 7.64 [194] 1.77 [45] 8.86 [225] 5.75 [146] 3.54 [90] [444] 4.61 [117] 1.38 [35] 0.98 [25] 8.50 [216] [752] 9.21 [234] 3.74 [95] 8.86 [225] 4.61 [117] TYPICAL INSTALLATION 8.50 [216] Water Supply To House Ball Valve Check Valve 5 feet or less Power Pressure Tank Pressure Reducing Valve (optional) Pressure Gauge Inline Pressure Boosting System Pressure Relief Valve Pressure Gauge Ball Valve Ball Valve Union Coupling Flow Union Coupling Pressure Reducing Valve (Optional) (Discharge into drain rated for max pump output at relief pressure) Allow a minimum of 20 inches (51 cm) for maintenance access *It is recommended (where applicable) to install the Inline 400 pump in PARALLEL with the incoming water supply. This will allow for a service bypass so that the typical household can still utilize the incoming water (albeit at a reduced pressure) if maintenance work is required. This type of installation requires a ball valve be installed as shown above. 9

12 INLINE CONSTANT PRESSURE - INLINE 1100 The Inline 1100 provides constant pressure for both private wells and municipal/city water systems. FEATURES Pump, motor, drive, and pressure switch in one box as a packaged system Small and compact design fits into small areas, even between floor joists Stainless steel construction for years of operation Simple and easy installation with step-by-step illustrated instructions Integrated motor design allows water to flow around it for quiet and cool operation NEMA 4 (IP56) electronics enclosure Multiple mounting configurations allow for the unit to be installed where you need it, whether horizontal, vertical, or even upside down Built-in system protections guard against many common failure modes including surge protection, voltage underload, locked pump, open circuit, short circuit, and overheated controller Product power rating: 1.2 hp, 0.9 kw Shipping weight: 50 lbs, 22.7 kg APPLICATIONS Boosted and constant water pressure from water storage/cistern systems Homes (both private and municipal applications) General pressure boosting Sprinkler systems Farming and commercial wash down systems CSA 108 UL 778 NSF/ANSI 372 ORDERING INFORMATION Model Description Order No. Input Voltage Input Phase 25SDIL1100N4* (Complete pump w/npt) SDIL1100N4-B* (Complete pump w/bsp) Electronic Drive Assembly Single Pump & Motor Assembly w/npt Pump & Motor Assembly w/bsp Mounting Feet Pressure Switch Pressure Tank (2 gallon) Fastener Kit Pressure Switch Cable N/A N/A Overpressure Switch** Overpressure Switch Cable** Overpressure Switch & Cable Combo** Thermostat Kit * Includes pump, motor, drive, pressure switch, and all cables. ** Overpressure switch is sold as an accessory and is not required for normal operation. 10

13 INLINE CONSTANT PRESSURE - INLINE 1100 PERFORMANCE METERS FEET PSI INCREMENTAL PRESSURE INCREASE RECOMMENDED OPERATING RANGE GPM L/MIN M 3 /H FLOW NOTE: Running outside of Recommended Operating Range for short periods of time is permissible. SYSTEM COMPONENTS Water Flow NEMA 4 (IP56) Drive Thermostat Secure Power Cord 1-1/4" NPT Inlet 1-1/4" NPT Outlet Stainless Steel Impellers Sealed Motor 11

14 INLINE CONSTANT PRESSURE - INLINE 1100 DIMENSIONS [478,7] TO THERMOSTAT [478,5] 1.50 [38,1] SUCTION SEE TABLE FOR SIZE DISCHARGE SEE TABLE FOR SIZE 9.31 [236,4] 6.65 [168,9] INPUT POWER [439,9] [265] 8.00 [203,2] 7.00 [177,8] 5.72 [145,2] 2.92 [74,1] 3.45 [87,7] TYPICAL INSTALLATION 5 FEET OR LESS WATER SUPPLY INLINE SYSTEM POWER 2 GALLON TANK PRESSURE SWITCH PRESSURE RELIEF VALVE PRESSURE GAUGE BALL VALVE TO HOME *CHECK VALVE OPTIONAL BYPASS BALL VALVE UNION COUPLING FLOW UNION COUPLING CHECK VALVE PRESSURE SHUT-OFF SWITCH (OPTIONAL) (DISCHARGE INTO DRAIN RATED FOR MAX PUMP OUTPUT AT RELIEF PRESSURE) BALL VALVE CHECK VALVE NOTE: These optional components are shown in a typical installation diagram. They should be used at the installer s discretion as required for particular applications. * When connected to a municipal system, if the plumbing does not have a backflow prevention device, a check valve is required on the incoming water supply line. If installed on a cistern, the check valve should be passive or be eliminated. 12

15

16 franklinwater.com M5049a 03-18

C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

C1N Series - Light Industrial Heaters Tankless Water Heating Solutions 18-25 kw (61,4000-85,300 BTUs) Low flow activation options at 0.25 and 0.50 GPM (1.0 and 1.9 LPM) Certified Lead-Free Design Variable Temp Heat Exchanger Pressure Drop Advantage NEMA 4 enclosure standard

More information

POULTRY MARKET CATALOG

POULTRY MARKET CATALOG POULTRY MARKET CATALOG FW0134 0518 Supersedes 0714 Evaporative Cooling Pumps: 1-1/2 or 2 in. discharge Centrifugal Booster Pumps Pressure Booster Pumps Engineered Poultry Pumping Systems One year limited

More information

Portable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions

Portable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions Portable C2N Series - Light Industrial Heaters Heavy duty industrial cart options simplify moving heater to various locations 36-50 kw (122,800-170,600 BTUs) Variable Temp Heat Exchanger Pressure Drop

More information

Portable C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

Portable C1N Series - Light Industrial Heaters Tankless Water Heating Solutions Heavy duty industrial cart options simplify moving heater to various locations 18-25 kw (61,4000-85,300 BTUs) Low flow activation options at 0.25 and 0.50 GPM (1.0 and 1.9 LPM) Certified Lead-Free Design

More information

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions 36-144 kw (122,800-491,300 BTUs) Certified Lead-Free Design New & Improved Pressure Drop Advantage Variable Temp Heat Exchanger NEMA 4 enclosure standard Independent Safeties ETL and cetl certified to

More information

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions 36-144 kw (122,800-491,300 BTUs) Temperature overshoot purge system Certified Lead-Free Design NEMA 4 enclosure standard ASME and NB Certified options available New & Improved Pressure Drop Advantage Dual

More information

SN Series - Safety Shower Heaters Tankless Water Heating Solutions

SN Series - Safety Shower Heaters Tankless Water Heating Solutions 36-144 kw (122,800-491,300 BTUs) Temperature overshoot purge system Lead-Free Design NEMA 4 enclosure standard ETL and cetl certified to UL and CSA Standards Liquid-Cooled Solid State Relays Internal fusing

More information

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications 36-144 kw (122,800-491,300 BTUs) Temperature overshoot purge system Certified Lead-Free Design NEMA 4 enclosure standard ASME and NB Certified options available Pressure Drop Advantage Dual Flow Activation

More information

Portable CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

Portable CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions Portable CNA-Series - Large Industrial Heaters Heavy duty industrial cart options simplify moving heater to various locations 36-72 kw (122,800-245,600 BTUs) Certified Lead-Free Design New & Improved Pressure

More information

ACT-4 AC Electronically Commutated Spherical Motor Centrifugal Pump Kit

ACT-4 AC Electronically Commutated Spherical Motor Centrifugal Pump Kit SPECIFICATIONS SS-20 ACT-4 AC Electronically Commutated Spherical Motor Centrifugal Pump Kit Application: Specifically designed for hot water recirculation in a residential or light commercial building.

More information

Plumbing. ECM High-Efficiency Hot Water Recirculation System. Instant hot water for existing plumbing systems; no dedicated return line needed

Plumbing. ECM High-Efficiency Hot Water Recirculation System. Instant hot water for existing plumbing systems; no dedicated return line needed Plumbing ECM High-Efficiency Hot Water Recirculation System Enjoy instant hot water comfort while avoiding a major renovation. The Hot-LinkPlus-e system installs easily into existing plumbing with a tank

More information

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions Pre-assembled skid system Back-to-Back heater models, SNA & SNAR High Flow Demand Safety Shower Applications 216-288 kw (737,000-983,000 BTUs) Temperature overshoot purge system NEMA 4 enclosure standard

More information

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers. SECTION 22 10 00 PLUMBING PIPING AND PUMPS PART 1 - GENERAL 1.1 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design.

More information

Tankless On Demand Electric Water Heater

Tankless On Demand Electric Water Heater ECO FRIENDLY 98% EFFICIENT ENERGY & WATER SAVING Model MTX Tankless On Demand Electric Water Heater Available Up To 54 KW in Single or Three Phase Voltages Marine Approvals American Bureau of Shipping

More information

Monticello Pump Services, Inc

Monticello Pump Services, Inc Constant Water Pressure Systems and Accessories Monticello Pump Services, Inc www.nowater.com About Us Operating since 1975 (Over 31 years) We specialize in Well Water, Sewage, Septic, and Sump Pumps Offering

More information

Taco 00 Series Cartridge Circulators

Taco 00 Series Cartridge Circulators Water Circulation Pumps & Circulators Taco 00 Series Cartridge Circulators For over 70 years, Taco has led the industry with the highest quality circulators you can buy. Designed for a wide range of residential

More information

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW MODEL V Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW Features Industrial Grade Construction Stainless steel pressure vessel provides maximum service

More information

Shop Online Eccotemp.com/products. Store Locator Eccotemp.com/locator. Product Support support.eccotemp.com.

Shop Online Eccotemp.com/products. Store Locator Eccotemp.com/locator. Product Support support.eccotemp.com. L5 20 minute automatic safety shutoff timer Battery igniter - no electricity needed Minimum flow rate is approximately 0.4 gallons per minute Up to 18 hours of use on a 20 lb. tank Shower head with On/Off

More information

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps Note: The A/E must choose all design values in brackets below before using in project specifications 1 General 1.1 Provide UL listed and FM approved fire pump complete with pump, driver, controller and

More information

City Water Booster Pump

City Water Booster Pump City Water Booster Pump W2041 0818 Supersedes NEW RAINING MODULE 1/2 and 1 HP, 115 V Pressures from 26 to 112 PSI low rates from 3 to 27 GPM City water booster pumps are available in two models: VP05 (1/2

More information

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL HOMEADVANTAGE II HA008240 HA011240 HA013240 HA018240 HA024240 HA027240 HA036240 IMPORTANT SAFETY INFORMATION When installing or using any high voltage electrical

More information

Standard Features. Performance/Capacities

Standard Features. Performance/Capacities TSC-66 Traditional Power/Connections Approximate Total Load AMPS 208V / 60HZ / 3PH 51.8 208V / 60HZ / 1PH 88.3 230V / 60HZ / 3PH 47.8 230V / 60HZ / 1PH 81.5 460V / 60HZ / 3PH 23.9 Booster Heater Options

More information

ECS Protector Nitrogen Generator PGEN-40FK/PGEN-50FK/PGEN-60FK PGEN-40M/PGEN-50M/PGEN-60M

ECS Protector Nitrogen Generator PGEN-40FK/PGEN-50FK/PGEN-60FK PGEN-40M/PGEN-50M/PGEN-60M ECS Protector PGEN-40/PGEN-50/PGEN-60 (PGEN-40E/PGEN-50E/PGEN-60E) For use under U.S. Patents 8,720,591, 9,144,700 and 9,186,533 Specifications Dimensions (cabinet): Dimensions (incl. bypass): Weight:

More information

Electric Submersible Pumps

Electric Submersible Pumps Electric Submersible Pumps Versatile pumps with a wide variety of applications Construction Starts Here www.multiquip.com Electric Submersible Pumps Bolt-on discharge port allows easy replacement Cast

More information

S19361F - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

S19361F - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions Pre-assembled, freeze-protected safety fixture and SNA heater skid system Bradley Heat Trace S19-300 with SpinTec 54-144 kw (491,300 BTUs) Molded Duragrate and integrated shower pan Temperature overshoot

More information

AQUAS POOL PACKAGE INSTALLATION INSTRUCTIONS FOR MODELS: AP AQUAS Pool Package

AQUAS POOL PACKAGE INSTALLATION INSTRUCTIONS FOR MODELS: AP AQUAS Pool Package 100285340_2000542910_Rev A AQUAS POOL PACKAGE INSTALLATION INSTRUCTIONS FOR MODELS: AP 400-850 AQUAS Pool Package The AQUAS pool package system is a high efficiency commercial condensing boiler, pre-piped

More information

Tepid Water Delivery System

Tepid Water Delivery System Provides Tepid Water For Emergency Fixtures Features Heavy Duty Construction Hydrastone cement lining provides tank longevity Copper-silicon alloy tappings cannot rust or corrode High impact composite

More information

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508 Electro-HELPS IX Boiler, Submittal Data Sheets These provide the mechanical technical details often required for architects/design engineers, shop drawings, etc. They are also useful in providing additional

More information

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages Model HX/TX Tankless Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages Features Heavy Duty Construction Constructed with high grade materials to ensure long operating

More information

CPF PRODUCT DESCRIPTION

CPF PRODUCT DESCRIPTION CPF 175 340 PRODUCT DESCRIPTION The CHICAGO PNEUMATIC CPF 175-340 compressor is a quiet, complete and ready-for-use unit for the production of compressed air in industrial applications. OVERVIEW The CHICAGO

More information

QUALITY PRODUCTS, INC. OIL-TO-AIR HEAT EXCHANGERS

QUALITY PRODUCTS, INC. OIL-TO-AIR HEAT EXCHANGERS OIL-TO-AIR HEAT EXCHANGERS Description BUCR Series Oil-To-Air Heat Exchangers 1 BUCR Series Oil-To-Air Heat Exchangers He The BUCR Series heat exchangers are designed to stabilize the oil temperature and

More information

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

5231 Series.   Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341 NA31 www.caleffi.com Low Lead High Flow Thermostatic Mixing Valves Copyright 1 Caleffi Installation, commissioning and service instructions Function 531 Series ASSE 17 model 531 series high flow thermostatic

More information

The Finest Tankless Electric Water Heaters Available! Commercial Application Point-of-Use Tankless Electric

The Finest Tankless Electric Water Heaters Available! Commercial Application Point-of-Use Tankless Electric Commercial Application Point-of-Use Tankless Electric DHC -E DHC-E Tempra The Finest Tankless Electric Water Heaters Available! On-demand, continuous, unlimited hot water No venting required Exclusive

More information

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D

J120 STEAM BOOSTER INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER. J120 Steam Booster Manual D INSTALLATION, OPERATION, AND SERVICE MANUAL J120 STEAM BOOSTER J120 STEAM BOOSTER J120 Steam Booster Manual REVISION HISTORY Revision Letter Revision Date Made by Applicable ECNs Details A 10-27-04 CBW

More information

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION As when installing or using any high voltage electrical appliance, basic safety precautions should always

More information

AQUAS POOL PACKAGE INSTALLATION INSTRUCTIONS FOR MODELS: XPN AQUAS Pool Package

AQUAS POOL PACKAGE INSTALLATION INSTRUCTIONS FOR MODELS: XPN AQUAS Pool Package AQUAS POOL PACKAGE INSTALLATION INSTRUCTIONS FOR MODELS: XPN 400 801 AQUAS Pool Package The AQUAS pool package system is a high efficiency commercial condensing boiler, pre-piped package system from the

More information

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages Point-of-Use Tankless Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages Features Heavy Duty Construction Reliability Constructed with high grade materials to ensure long operating

More information

PRO SERIES IMPORTANT SAFETY INFORMATION

PRO SERIES IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL PRO SERIES IMPORTANT SAFETY INFORMATION When installing or using any high voltage electrical appliance, basic safety precautions should always be followed.

More information

AccuBrine automated brine maker Technical Specifications

AccuBrine automated brine maker Technical Specifications Cargill Deicing Technology AccuBrine automated brine maker Technical Specifications All 4 models included Automated Blending System Model (ABM) Automated Blending Remote Truck Fill Model (ABRTF) Automated

More information

08/17/2011 Rev. 4 PULL STATION EXHAUST HOOD 10 TO 20 FEET FROM HOOD LOCATE ONE NEAR EVERY POINT OF EGRESS FROM HOOD

08/17/2011 Rev. 4 PULL STATION EXHAUST HOOD 10 TO 20 FEET FROM HOOD LOCATE ONE NEAR EVERY POINT OF EGRESS FROM HOOD 24V CORE TOTAL FLOOD PROTECTION INSTALLATION SUMMARY CORE WATER LINE- 30 TO 70 PSI OPERATING PRESSURE, 90 PSI MAX STATIC PRESSURE, 1.5 GPM PER FOOT OF HOOD 3/4 INCH NPT FITTING, CONNECTED TO SUPERVISED,

More information

PROVIDES TEPID WATER FOR EMERGENCY SHOWER

PROVIDES TEPID WATER FOR EMERGENCY SHOWER PROVIDES TEPID WATER FOR EMERGENCY SHOWER Model EMV FEATURES Heavy Duty Construction Hydrastone cement lining provides tank longevity Copper-silicon alloy tappings cannot rust or corrode High impact composite

More information

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase Features Heavy Duty Construction Constructed with high grade materials to ensure long operating life Turn-Key package is simple to specify and operate Factory wired electrical controls provide trouble-free

More information

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY 24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY 06/13/2011 Rev. 6 Pollution Control Unit PCU CORE CONNECTIONS, 3/8" NPT CONNECTION, ONE PER MODULE LINE FROM PACKAGE MUST BE BRANCHED TO EACH MODULE..

More information

LC Series - Light Commercial Pump Station Installation and Operation Manual

LC Series - Light Commercial Pump Station Installation and Operation Manual LC Series - Light Commercial Pump Station Installation and Operation Manual Please keep this manual with the pump station Content Rain Bird LC Series Overview... Safety Instruction... Operation... 3 Pump

More information

Constant Water Pressure Systems and Accessories

Constant Water Pressure Systems and Accessories Constant Water Pressure Systems and Accessories Monticello Pump Service www.nowater.com Owner-Paul Keplinger Co-Owner Owner-Jason Kyer About Us Operating since 1975 (Over 31 years) We specialize in Well

More information

FREE. Functions and Features:

FREE. Functions and Features: IMPORTANT SAFETY INFORMATION DO NOT DISCARD O P E R AT I O N M A N U A L TM TM FREE instructi are availabonal videos youtu le online at: be.com TM IMPORTANT SAFETY INFORMATION DO NOT DISCARD Adjustable

More information

Liebert Xtreme Density Chiller (XDC) Unit Warranty Inspection Check Sheet

Liebert Xtreme Density Chiller (XDC) Unit Warranty Inspection Check Sheet The following information must be completed and forwarded to your local Liebert sales office to establish your equipment warranty. Installer Address Owner Address Owner e-mail address Date of Installation:

More information

WATER CONTROL VALVES

WATER CONTROL VALVES CASH ACME CATALOG WATER CONTROL VALVES THAT STAND THE TEST OF TIME In 1893, A.W. Cash designed a valve for U.S. Navy submarines. With the bottom of the sea as his testing ground, the valve became celebrated

More information

DRAINMAKER INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

DRAINMAKER INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST Manufacturers of... Quality Products since 1866 95 N. Oak St. Kendallville, IN 46755 1-800-345-9422 DRAINMAKER INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST FW0771 0116 Supersedes 0415 MODEL: DATE

More information

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, Dual-Purpose Water Supply, Domestic and Fire Sprinkler System General Description

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, Dual-Purpose Water Supply, Domestic and Fire Sprinkler System General Description Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, Dual-Purpose Water Supply, Domestic and Fire Sprinkler System General Description The TYCO RAPID RESPONSE Model

More information

Indirect Fired Water Heater

Indirect Fired Water Heater Indirect Fired Water Heater 35-119 Gallon Capacities Features Heavy Duty Construction Hydrastone cement lining provides long tank life Copper-silicon tappings cannot rust or corrode High impact composite

More information

MODEL MW200 MODEL MW600 AIR DRYER

MODEL MW200 MODEL MW600 AIR DRYER OPERATING MANUAL MODEL MW200 MODEL MW600 AIR DRYER Mail Address: 226A Commerce St. Tel: 303-465-3063 Broomfield, CO 80020 Fax: 303-465-9294 TABLE OF CONTENTS 1.0 GENERAL...3 2.0 SPECIFICATIONS...3 3.0

More information

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341.

5231 Series.  Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341. NA3. www.caleffi.com Low Lead High Flow Thermostatic Mixing Valves Copyright 5 Caleffi Installation, commissioning and service instructions Function 53 Series ASSE 7 model 53 series high fl ow thermostatic

More information

DualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System

DualPak Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Sept. 28, DualPak 6900 Series Booster System DualPak Series 6900 FILE NO: 62.11 DATE: Feb. 15, 1999 SUPERSEDES: 62.11 DATE: Sept. 28, 1995 DualPak 6900 Series Booster System D U A L P A K 6 9 0 0 Armstrong proudly presents the Series 6900 DualPak

More information

Owner s Manual Therma-Stor II Heat Recovery System

Owner s Manual Therma-Stor II Heat Recovery System PO Box 8680 Madison, WI 53708 TS-138C Revised 8/08 Owner s Manual Therma-Stor II Heat Recovery System Installation, Operation & Service Instructions Read and Save These Instructions Table Of Contents 1.

More information

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page

150-3,000 scfm AEHD Series. Desiccant Air Dryers AEHD Series. Externally Heated Desiccant Air Dryer 150-3,000 scfm. Front Page 150-3,000 scfm AEHD Series Desiccant Air Dryers AEHD Series Externally Heated Desiccant Air Dryer 150-3,000 scfm Front Page 1 AEHD Series Heated Dryer Externally Heated Desiccant Dryer 150-3,000 scfm Since

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

USER MANUAL/Installation Instructions LRV-4

USER MANUAL/Installation Instructions LRV-4 USER MANUAL/Installation Instructions LRV-4 Sierra Dental Products LLC 1953 W Gulf to Lake Hwy, Lecanto, FL 34461 Ofc.# 352-527-1975 FAX# 352-513-4801 www.dentalvacuums.com Email: Sierradentalproducts@Outlook.com

More information

water source / fan coils

water source / fan coils MANUAL BALL ALE W/MEMORY STOP (BMS) An adjustable stop position lever to limit travel of the On/Off handle. This allows the ball valve to be closed, and returned to the balance setting position without

More information

SS-THVD2-1/2 THERMOSTATIC VALVE WITH 2 WAY DIVERTER SS-THVD3-1/2 THERMOSTATIC VALVE WITH 3 WAY DIVERTER

SS-THVD2-1/2 THERMOSTATIC VALVE WITH 2 WAY DIVERTER SS-THVD3-1/2 THERMOSTATIC VALVE WITH 3 WAY DIVERTER SS-THVD2-1/2 THERMOSTATIC VALVE WITH 2 WAY DIVERTER SS-THVD3-1/2 THERMOSTATIC VALVE WITH 3 WAY DIVERTER Features: Ability to pre-select water temperature thus conserving water Paraffin wax element maintains

More information

The smart way to instant hot water comfort.

The smart way to instant hot water comfort. The smart way to instant hot water comfort. Patent# US 8, 594, 853 B Taco Catalog # 100-97 Supersedes: 10/0/15 Effective Date: 03/31/17 Printed in USA The Problem: Waiting for Hot Water It s a common problem:

More information

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

4VH and 4VHX. 4 Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction 4VH and 4VHX 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction DURABLE MOTOR WILL DELIVER MANY YEARS OF RELIABLE SERVICE Oil-filled motor for maximum heat dissipation

More information

Mission Critical. Fuel Supply Systems

Mission Critical. Fuel Supply Systems Fuel Supply Systems Insight Onsite Fuel Supply Systems Page 2 Simplex Mission Critical Fuel Supply Systems are comprehensive, integrated, project-matched fuel management systems for diesel and turbine

More information

CR1 Series Triton Corrosion Resistant Washdown Heaters

CR1 Series Triton Corrosion Resistant Washdown Heaters CR1 Series Triton Corrosion Resistant Washdown Heaters Ruffneck CR1 Triton Series is a new generation of NEMA 4X corrosion-resistant washdown heaters. The first UL listed Type 4X heater with models ranging

More information

ROTARY SCREW COMPRESSOR CSM MAXI 7, HP

ROTARY SCREW COMPRESSOR CSM MAXI 7, HP ROTARY SCREW COMPRESSOR CSM MAXI 7,5-10 - 15-20 HP LABORATORY INDUSTRY CUSTOMER SERVICE The CSM Maxi Range MAXI 7,5-10 - 15-20 HP A solution to satisfy all needs Base Mounted Version Especially recommended

More information

Quick Start Guide. For product manuals and further installation / operation procedures visit

Quick Start Guide. For product manuals and further installation / operation procedures visit Quick Start Guide For product manuals and further installation / operation procedures visit www.aquacal.com Important Read This Guide Before Installing or Operating Heat Pump LTP0093 Rev 1 03/21/2014 Page

More information

OPERATION MANUAL OPERATION MANUAL FREE. instructional videos are available online at: youtube.com IMPORTANT SAFETY INFORMATION DO NOT DISCARD

OPERATION MANUAL OPERATION MANUAL FREE. instructional videos are available online at: youtube.com IMPORTANT SAFETY INFORMATION DO NOT DISCARD IMPORTANT SAFETY INFORMATION DO NOT DISCARD OPERATION MANUAL TM FREE instructional videos are available online at: youtube.com IMPORTANT SAFETY INFORMATION DO NOT DISCARD OPERATION MANUAL 2 A F J G H B

More information

QUICK PRIME INSTALLATION AND SERVICE MANUAL

QUICK PRIME INSTALLATION AND SERVICE MANUAL QUICK PRIME INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party who maintains the system. Part #

More information

JET, PERIPHERAL TURBINE, HORIZONTAL MULTISTAGE & CENTRIFUGAL PUMPS + ELECTRONIC PRESSURE CONTROLLERS & WATERGATE PRO RS ABOVE GROUND PUMPS

JET, PERIPHERAL TURBINE, HORIZONTAL MULTISTAGE & CENTRIFUGAL PUMPS + ELECTRONIC PRESSURE CONTROLLERS & WATERGATE PRO RS ABOVE GROUND PUMPS A NORMA Group brand JET, PERIPHERAL TURBINE, HORIZONTAL MULTISTAGE & CENTRIFUGAL PUMPS + ELECTRONIC PRESSURE CONTROLLERS & WATERGATE PRO RS 1300 252 677 sales.au@normagroup.com www.normagroup.com.au A

More information

WH231/WR231. General Features. Operational Information. Discharge 11 gpm at 40 psig (0.69 lps at 28 m) 7.8 gpm at 80 psig (0.

WH231/WR231. General Features. Operational Information. Discharge 11 gpm at 40 psig (0.69 lps at 28 m) 7.8 gpm at 80 psig (0. WH231/WR231 General Features The model WH231 or WR231 grinder pump station is a complete unit that includes: the grinder pump, check valve, polyethylene tank, controls, and alarm panel. The lower portion

More information

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY 24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY 11/12/2012 Rev. 10 Pollution Control Unit PCU CORE CONNECTIONS, 3/8" NPT CONNECTION, ONE PER MODULE LINE FROM PACKAGE MUST BE BRANCHED AND ADAPTED TO EACH

More information

FBSMS FLUX BOOSTING SYSTEMS

FBSMS FLUX BOOSTING SYSTEMS FBSMS FLUX BOOSTING SYSTEMS Aplications FLUX BOOSTING SYSTEM is made up of a water pump and an electronic pump controller which is used for: Residential irrigation applications when is necessary to boost

More information

ROTARY SCREW COMPRESSOR MSM MAXI 5,5-7, kw

ROTARY SCREW COMPRESSOR MSM MAXI 5,5-7, kw ROTARY SCREW COMPRESSOR MSM MAXI kw INDUSTRY CUSTOMER SERVICE The MSM Maxi Range MAXI kw A solution to satisfy all needs Base Mounted Version Especially recommended for installations near the place of

More information

Vacuum Systems. A complete line of vacuum pumps and accessories for every dairy

Vacuum Systems. A complete line of vacuum pumps and accessories for every dairy Vacuum Systems A complete line of vacuum pumps and accessories for every dairy 2 GEA VACUUM SYSTEMS CL Vacuum Pump Exclusive coated lobes increase efficiency Commercial grade lobe style vacuum pump designed

More information

INSTALLATION & TESTING MANUAL

INSTALLATION & TESTING MANUAL LP LOW PRESSURE UNIT ISO9001 CERTIFIED INSTALLATION & TESTING MANUAL ***CAUTION: Do not lift by yellow enclosure. Reference installation instructions for proper lifting and moving techniques. INSTALLATION

More information

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE.

YOUR PROCESS DEMANDS THE MOST DEPENDABLE TEMPERATURE CONTROL UNIT AVAILABLE. Temperature Control Units Water & Oil 0-00 F Portable Chillers 0 - F Central Chillers Packages & Modules 0 - F Pump Tank Stations Chilled or Tower Water 00-0 gallons Cooling Tower Cells 4-40 tons Filters

More information

INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16

INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16 INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16 CROWN FOOD SERVICE EQUIPMENT LTD. 70 OAKDALE ROAD, DOWNSVIEW, (TORONTO), ONTARIO, CANADA, M3N 1V9 TELEPHONE: (416) 746-2358,

More information

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL AUTOBOOSTER IMPORTANT SAFETY INFORMATION

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL AUTOBOOSTER IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL AUTOBOOSTER IMPORTANT SAFETY INFORMATION When installing or using any high voltage electrical appliance, basic safety precautions should always be followed.

More information

TEMPERATURE CONTROLLERS

TEMPERATURE CONTROLLERS Instruction Manual: H1 T-12 Thermostat PILOT GUARD INTRODUCTION: SCOPE: This instruction manual includes installation, operation, and parts information for the Kimray Thermostat and Pilot Guard. Refer

More information

SYSTEMS for CATALYTIC FILTERS

SYSTEMS for CATALYTIC FILTERS OP40U5F, OP40B5F, OP80U10F, OP80B10F, OP120U15F & OP120B15F INSTALLATION, OPERATION & SERVICE INSTRUCTIONS Hydrogen Sulfide Removal SYSTEMS for CATALYTIC FILTERS NO DIAPHRAGMS OR AIR CELLS COMPLETELY CORROSION

More information

Model NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Model NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS 1455 Kleppe Lane Sparks, NV 89431-6467 (775) 359-4712 Fax (775) 359-7424 E-mail: haws@hawsco.com website: www.hawsco.com Model 9400 No. 2080243(7) NOTE

More information

Steamist Installation Guidelines

Steamist Installation Guidelines Steamist Installation Guidelines The Heavy Commercial steam generator (HC-9 thru HC-18) comes from the factory assembled, carefully wired, and tested. Please read all instructions before installing or

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL 216300-000 rev2 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM FOR HAZARDOUS LOCATIONS MODEL OSE OSX (this page intentionally left blank) IDENTIFYING YOUR SYSTEM IOM216300-000 The HOTSTART

More information

Davies Carries Parts for MF & SF Series Glycol Feeders

Davies Carries Parts for MF & SF Series Glycol Feeders Chemical Bypass Feeders B24 Feeders Delivers chemicals to any closed loop system. Maintaining a chemically balanced hydronic system has never been easier Allows for safe and easy chemical dosing. Ball

More information

REFRIGERANT RECOVERY SYSTEMS

REFRIGERANT RECOVERY SYSTEMS REFRIGERANT RECOVERY 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com RECOVERY YELLOW JACKET HVAC&R HOSES YELLOW JACKET YJ-LTE Refrigerant

More information

POINT-OF-USE WATER HEATERS

POINT-OF-USE WATER HEATERS POINT-OF-USE WATER HEATERS HEATING WATER FOR OVER 50 YEARS INSTANT-FLOW C-MICRO (CM SERIES) Low Activation - 0.20 gpm MINI TANK (CMT SERIES) 1.3 to 6.0 Gallons BOXER (ERB SERIES) 2.6 to 30 gpm A B A. CHRONOMITE

More information

Refrigerant Valves/Accessories

Refrigerant Valves/Accessories Inline Check Valves Compact in-line (non-return) check valves for closure upon pressure reversals. Low Pressure Drop Mounts In Any Position Stainless Steel Disc Safe Working Pressure 400psig Operating

More information

Table of Contents. FETCO, and Driven To Pioneer Innovation are trademarks or trade names of Food Equipment Technologies Company.

Table of Contents. FETCO, and Driven To Pioneer Innovation are trademarks or trade names of Food Equipment Technologies Company. www.fetco.com Hot Water Dispensers User s Guide Maritime Versions Rated IP44 Table of Contents Contact Information... 2 Specifications... 2 Dimensions... 3 Installation... 4 Operating Instructions...6

More information

Submersible. Pumps Motors. 50Hz 12 Submersible Pump. Pumping Solution

Submersible. Pumps Motors. 50Hz 12 Submersible Pump. Pumping Solution Submersible Pumps Motors 50Hz 2 Submersible Pump Pumping Solution 65 Product data 2 Submersible bore well pumps Construction Submersible motor & pumps for deep wells of 2 (DN 300 mm). Sized for connection

More information

S19361HF - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

S19361HF - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions Pre-assembled, freeze-protected safety fixture and SNA heater skid system Bradley Heat Trace S19-304 with SpinTec 54-144 kw (491,300 BTUs) Molded Duragrate and integrated shower pan Temperature overshoot

More information

SMARTBOOST IMPORTANT SAFETY INFORMATION

SMARTBOOST IMPORTANT SAFETY INFORMATION INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL SMARTBOOST IMPORTANT SAFETY INFORMATION When installing or using any high voltage electrical appliance, basic safety precautions should always be followed.

More information

Electric Submersible Pumps

Electric Submersible Pumps Electric Submersible Pumps Versatile pumps with a wide variety of applications www.multiquip.com Electric Submersible Pumps Bolt-on discharge port allows easy replacement Cast aluminum housing for light

More information

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10) Use & Care Manual With Installation Instructions for the Installer Electric Tankless Water Heaters The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations

More information

1600 Series Rotating Suction Screen

1600 Series Rotating Suction Screen INTRODUCTION The 1600 Series Rotating Suction Screen is an Electric Motor (Hydraulic Option Available) driven, Self-Cleaning Suction Screen. It is ideally used for pumping water from canals, reservoirs,

More information

L A signature series TA T N E RE O, A L L A T S IN

L A signature series TA T N E RE O, A L L A T S IN signature series COMMERCIAL STEAM GENERATORS INSTALLATION, OPERATION AND MAINTENANCE MANUAL INSTALLATION MANUAL COMMERCIAL STEAM GENERATOR SIGNATURE SERIES (SS) INTRODUCTION Steam Sauna manufactures steam

More information

VENTLESS DOOR-TYPE DISHWASHER

VENTLESS DOOR-TYPE DISHWASHER Item # Quantity C.S.I. Section 11400 VENTLESS STANDARD FEATURES Internal condensing system minimizes water vapor Does not require a vent hood Energy recovery Sense-A-Temp 70 F rise electric booster heater.74

More information

InterSeptor Centrifugal Separators Operating & Maintenance Manual

InterSeptor Centrifugal Separators Operating & Maintenance Manual General Information: This manual was prepared to assist in the installation, operation, and maintenance of PEP ICS centrifugal separator systems. For immediate response to questions not covered in this

More information

INSTALLATION, OPERATION AND MAINTENANCE

INSTALLATION, OPERATION AND MAINTENANCE INLINE HEATER INSTALLATION, OPERATION AND MAINTENANCE MODELS: ILS SERIES 1.5kW 120V SINGLE PHASE BEFORE YOU BEGIN CHECK ALL ELECTRICAL CONNECTIONS TO ALL COMPONENTS WITHIN THE HEATER FOR TIGHTNESS. CONNECTIONS

More information

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS SECTION 22 20 00 LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements",

More information

HEATING- Heating Accessories RW List Prices Page X - 1. Bronze B&G Circulator Pumps. Iron Body Red Fox B&G Circulator Pump

HEATING- Heating Accessories RW List Prices Page X - 1. Bronze B&G Circulator Pumps. Iron Body Red Fox B&G Circulator Pump Iron Body Red Fox B&G Circulator Pump A residential or light commercial, maintenance-free, in-line lead-free cast iron wet rotor circulator heating systems. HEATING- Heating Accessories RW List Prices

More information