Heat Transfer Enhancement from Heat Sinks using Perforated Fins: A Review

Size: px
Start display at page:

Download "Heat Transfer Enhancement from Heat Sinks using Perforated Fins: A Review"

Transcription

1 Heat Transfer Enhancement from Heat Sinks using Perforated Fins: A Review A A Kanaskar V M Kriplani PV Walke Student, MTech Professor, Professor, (Heat Power Engineering) Mechanical Engineering Dept Mechanical Engineering Dept GH Raisoni College of Engineering GH Raisoni College of Engineering GH Raisoni College of Engineering Nagpur-16, Maharashtra, India Nagpur-16, Maharashtra, India Nagpur-16, Maharashtra, India Abstract - The present review paper contribute the experimental analysis of the heat transfer growth and the respective pressure drop below a flat surface embedded with ring shaped or circular square perforated fins in a rectangular manner Extended surfaces (fins) are frequently used as heat exchange appliances to enhance the heat transfer between the primary surface and surrounding liquid Fins are extensively usage as heat exchange appliances The fins are widely usage for various industrial applications Other modes of fins are rectangular, rounded, narrowing, ring shaped pin fins or mixture of other geometries has been used Gas turbines of the blades, electronic cooling, and aerospace application are the few application of short fins Long fins have applications where attainment of high heat transfer is major concerned Fins provide large total surface area without the use of a large primary surface area Keywords: Perforated fins, Fin performance, Thermal performance I INTRODUCTION The augmentation of the heat transfer is very essential to thermal engineering The heat transfer from the surface may in general be enhanced by rising the heat transfer between a surface and its surrounding by rising the heat transfer area of the surface Rectangular fins, square fins and rounded fins are used for both natural and forced convection of heat transfer Other modes of heat exchanging fins, ranging from similarly shapes, like orthogonal, ring shaped, cylindrical, narrowing or pin fins, to a mixture of other geometries have been used In engineering applications, heat generation can cause overheating, cooling electronic equipment, heating and cooling in evaporator, radiator in vehicles, refrigerator, gas turbine blade, as well as aerospace industry efficient surface area They normally use geometrical changes to the flow channel by compilation inserts or extra appliances They promote higher coefficient of heat transfer by interrupting or to changing the existent flow behavior except for extended surfaces Heat transfer enhances by this method can be accomplished by using these surfaces are treated, rough, and swirl flow like techniques Following are generally used in passive heat transfer augmentation tools a) Ribs b) fins c) pits d) coils of the wire C Compound techniques: Compound technique is a hybrid technique in which both active as well as passive techniques are used in combination The compound technique needs composite design II REVIEW OF WORK CARRIED OUT Bayram Sahin, Alparslan Demir [1]carried out the performance of heat transfer Augmentation with related pressure drop through a rectangular channel with circular fins attached to a flat surface Reynolds number ranges are selected for this experiment ,000 They defined the clearance ratio of space above fins to the height of fin in rectangular channel They found that average Nusselt number and friction factor enhanced with reducing clearance ratio and interfin spacing ratio Rise of the efficiencies varied at middle 11 and 19 reliant for both the ratio Various methods of heat transfer augmentation A Active method This system needs external power to the growing of the heat transfer There are various specimens of active techniques are that which produces effect pulsating by cams, reciprocating pump-piston etc B Passive method These techniques do not need any external power Fins are specimen of passive techniques that are popularly used in variety of industrial usage to augment the rate of heat transfer centrally initial surface and ambient liquid Convective heat transfer increases the heat transfer rate as to increase the Fig1 Experimental set up (1) 726 wwwijaegtcom

2 Ahmad Khoshnevis et al [2] carried out the study of the outcome of lateral surface perforation on heat transfer intensification of a 3-D channel with a ground attached heater Hole and slot were two types of perforation are studied Ranges of work: Re number and 005 to 015 that is open area perforation ratio Their results significantly augmentation in the heat transfer and pressure drop by rising the perforation area due to disorganizing the thermal traps distinguish the ribs Ahmad Khoshnevis et al [2] carried out the effect of extended surface perforation on heat transfer augmentation of a 3-D channel with a ground attached heater Two types of perforation are studied, ie Hole and slot Ranges of work: Re number and open area perforation ratio 005 to 015 perforation inclination angle: 0<o<45 t Their results show significant augmentation in heat transfer and pressure drop by increases the perforation area due to disorganizing the thermal traps between the ribs MR Shaeri, M Yaghoubi [3] carried out on the heat transfer augmentation and for 3-D liquid flow from grouping of solid as well as perforated fins that are attached to a horizontal sheet Air as effective liquid is used in both the equation like Navier- Stokes and RNG Reynolds number ranges are based on the fin length from to and Prandtl number Pr=071 Outcome show that fins with longitudinal pores have remarkable heat transfer augmentation in addition to the decrease in weight by comparison with solid fins EAM Elshafei [4], in this experiment they were performed on heat transfer from the rounded pin fin attached to a flat plate Heat sinks were generally spaced both the solid as well as perforated rounded pin fins with zigzagged or staggered combination, attached into a heated base of constant area Range of Reynolds no considered was 38x10 6 to 165x10 7 Perforated fins showing better performance than solid fins in the heat transfer analysis ON Sara [5] the paper shows that the convective heat transfer through a rectangular channel with square cross-section fins mounted below a flat surface The experimental outcomes showed that use of square fins may cause to benefit on the basis of heat transfer augmentation For higher heat transfer performance, less inter-fin distance ratio clearance ratio so that comparatively less Reynolds numbers should be important for the zigzagged arrangement They found that the average Nusselt number enhancing with reducing -fin distance clearance ratio and inter ratio, the friction factor enhancing with reducing clearance as well as inter-fin distance ratio Fig 2 experimental set up (5) Md Farhad Ismail et al, [6] in this experiment numerical study was performed to investigate the turbulent convection heat transfer on a rectangular plate mounted over a flat surface The extended surfaces were of various types of lateral perforations like rectangular, circular, hexagonal cross sections RANS based modified K-W turbulence model is usage to calculate the fluid flow and heat transfer parameters Reynolds number considered from 2000 to 5000 basis on the thickness of the fins Shape of lateral perforation has significant effects on the heat transfer behavior of heat sinks below turbulent flow conditions Rectangular perforated fins have the lowest and solid fins getting higher Nu number Hexagonal perforated fins have the highest fin usefulness Triangular perforated fins have lowest skin friction coefficient Fig 3: Three perforation of rounded, hexagonal, square, trilateral arrangement [6] 727 wwwijaegtcom

3 Rasim Karabacak, Gülay Yakar [7] In this experimentally studied, diameter holes were 6 mm on each circular fin on a heating tube that inline arrangement in order to growth of the heat transfer The holes invented turbulence in a region nearby the heating tube surface on the bottom of the fin They observe the differences between, perforated finned heaters along with imperforate finned heater with both additions Perforated finned locations are 12% more than the imperforate state in the Nusselt numbers Mohammad Reza Shaeri, Tien-Chien Jen [8],in their merical investigation they selected fin with greater porosity and with no change of its porosity, the number were varied to study the effects of perforation sizes on laminar heat transfer characteristics of the fins In this experiment they were using the Navier Stokes and energy equations are solved finite volume with the help of SIMPLE algorithm Fin with less perforation is more efficient to increase the heat transfer rate compared with a fin with more perforations Fig 4: Configuration of fin group [8] Tzer-Ming Jeng, Sheng-Chung Tzeng, [9] carried out the heat transfer performance analysis with seven square pin fins fitted to a flat surface with different arrangement are studied The outcomes show that lower part facing orientation yields the less coefficient of heat transfer It is observed that the sideward arrangement outcome of the upward one for small finning factors below 27 The optimal heat sink porosity for both upward and sideward arrangement is around 83%and 91% the addition of surface higher effective for the downward as well as lower effective for the sideward arrangement Ren-Tsung Huang el at, [10] experimentally studied the heat transfer of a square pin fin of a square fin array in a rectangular channel with the help of the transient single-blow method Longitudinal pitch the relative transverse pitch as well as the both zigzagged or staggered and line arrangement are the variable parameters The performance of the square fins as the cooling appliances is compared with that of the circular pin fns The optimal inter-fin pitches along with the largest Nu number under the similar pumping power, then XT = 2 and XL = 15 as well as XT = 15 and XL = 15 for the arrays in line as well as staggered arrangements (Relative longitudinal and transversal pitch were denoted as XT and XL) Monoj Baruah el at, [11] they carried out the computational investigation to assess the heat transfer characteristic of elliptical pin fins organized in a rectangular duct in a zigzagged manner They considered solid as well as perforated elliptical pin fins with three perforations They claimed that by changing the solid elliptical fin into the perforated elliptical pin fin, the pressure drop decreases by an average of 12% and heat transfer increases by 23% by introducing perforations and this performance may be further improved by increasing the numbers of perforations in elliptical pin fin Kavita H Dhanawade et at, [12] experimental to investigate the heat transfer Enhancement over horizontal flat plate surface with rectangular fin arrays will lateral square and circular perforation by force convection They varied sizes of perforation as well as Re from 21x10 4 to 87x10 4 They found that average of percentage improvement of square perforated fin is more than that of the fin array of circular perforated fin of same size Friction factor slightly increases with increase in the size of perforation This type of arrays can becomes for air cooling of IC engines and other industrial application A) Fig 5 Schematic of the experimental set up [9] 728 wwwijaegtcom B)

4 C) Fig 6Schematic of the square, circular, solid fin in line arrangement [12 ABGanorkar, VMKriplani [13] studied whole performance of suitable designed lateral perforated fins in a rectangular channel, Different type of perforated fins are used in the rectangular channel Effect of perforated fins in a rectangular channel is observed for other Reynolds numbers In respect of the Nusselt numbers as well as heat transfer coefficient were analyzed Reynolds number range taken , diameter range of holes 6-10 mm As Re number raises the ratio of (Nu perforated/nu solid) fin increases Increase in no Of holes, the ratio (Nu perforated/nu solid) increases Increase in diameter of holes the ratio (Nu perforated/nu solid) increases The enhancement of (Nu perforated/nu solid) is not significant with increase in no Of holes Advances in electronic engineering have significant changes in size and density of high performances chips Advances in electronic engineering have significant changes in size and density of high performances in size and density of high performances chips Thermal management of these small, high flux dissipater chips is an important issue in order to keep them in order Active method consists of certain external power for the augmentation of the heat transfer Some specimens of active method cause pulsating by cams, reciprocating pumppiston etc Passive techniques normally usage surface or geometrical conversions to the flow channel by compilation inserts or extra appliances, for few specimens, wire coils, extended surface appliances, mesh inserts References [1] Bayram Sachin, Alparslan Demir, Performance analysis of a heat exchanger having perforated square fins Applied Thermal Engineering28(2008) [2] Ahmad khoshnevis, faramarze talati, maziyar jalaal, esmaeil esmaeilzadeh, Heat transfer enhancement of slot & hole shape perforation in rectangular ribs of a 3-D channel, 17 th Annual (International) conference on mechanical engineering- ISME2009, university of Tehran, Iran [3] MR Shaeri, M Yaghoubi, Numerical analysis of turbulent convection heat transfer from an array of perforated fins, International Journal of Heat and Fluid flow 30 (2009) [4] EAM Elshafei, Natural convection heat transfer from a heat sink with hollow/perforated circular pin fin, thermal issues in emerging technologies, Theta 3, Cairo, Egypt, Dec nd 2010 Fig7Experimental set up [13] Abdullah H Alessa, Mohamad I Al-Widyan, [14] studied augmentation of heat transfer from a horizontal rectangular fin inserted with wedge shaped or triangular perforations below natural condition Geometrical measurement of fin and perforations are the parameters considered In this experiment, the heat wastage from the perforated fin for definite distance of wedge shaped or triangular perforation measurement, spaces between perforations the outcome in improvement in heat transfer ended the corresponding solid fin Growth of the heat transfer of the perforated fin rises as fin thermal conductivity is increased Advances CONCLUSION Augmentation of heat transfer is very useful in many industrial purposes Very quick heat extraction from heated surface, lowering material weight as well as cost has become a greater task for design for heat exchanger equipment Modernize of heat exchangers needs efficient techniques fabrication of heat exchangers to exchange great amount of heat between extended surfaces and ambient liquid [5] ONSara, Performance analysis of rectangular ducts with staggered square pin fins, Energy conversion and management 44(2003) [6] Md Farhad Ismail,Muhammad Noman Hasan,Suvash Csaha Numerical study of turbulent fluid flow and heat transfer in lareral perforated extended surfaces Energy 64(2014) [7] Rasim Karabacak,Gulay Yakar, Forced convection heat transfer and pressure drop for a horizontal cylinder with vertically attached imperforate and perforated circular fins Energy conversion and management 52(2011) [8] Mohammad Reza Shaeri,Tin-Chien Jen, The effect of perforation Sizes on laminar heat transfer characteristics of an array of perforated fins [9] Ren-Tsung Huang, Wen-Junn Sheu,Chi-Chuan Wang, Orientation Effect on natural convection convective performance of square pin fin Heat sinks International Journal of heat and mass transfer51(2008) mastransfer51(2008) [10] Tzer-mingjeng,Sheng-chung Tzeng, Pressure drop and heat Transfer of square pin-finarrays in-line and staggere arrangment International Journal of Heat and Mass Transfer 50 (2007) [11] Monoj Baruah,Anupam Dewan, PMahanta Performance of elliptical Pin heat exchanger with three elliptical perforations Deparmental of Mechanical engg,indian instistute of technology 729 wwwijaegtcom

5 guwahati, Vol 3(2) 2011 [12] Kavita H Dhanwade, Vivek K Sunnapwar,Hanamant SDhanawade, Theraml analysis of square and circular perforated fin arrays by Forced Convection International Journal of current Engineering 26 (2006) [13] AB Ganorkar, VMKriplani Experimental study of Heat transfer Rate by Using lateral perforated fins in a rectangular channel MIT International Journal of Mechanical engineeringvol 2, No 2, Aug 2012, pp (91-96)ISSN No [14] Abdullah H Alessa, Mohamad I Al-Widyan, Enhancement of Natural convection heat transfer from a fin by triangular perforation of bases parallel and toward its tip Jordan University of Science and Technology, Irbid, JordanAppl Math Mech -EnglEd2008, 29(8): wwwijaegtcom

Natural Convection Heat Transfer Augmentation from Heat Sinks using Perforated Fins: A Review

Natural Convection Heat Transfer Augmentation from Heat Sinks using Perforated Fins: A Review (JMSME) Print ISSN : 2339-9095; Online ISSN : 2393-9109; Volume 2, Number 6; April June, 2015 pp 80 84 Krishi Sanskriti Publications http://www.krishisanskriti.org/jmsme.html Natural Convection Heat Transfer

More information

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack #1 Digvijay A. Shelar, #2 N.S. Gohel, #3 R. S. Jha #1 Mechanical Engineering Department,

More information

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts International Journal of Current Engineering and Technology E-ISSN 2277 416, P-ISSN 2347 5161 216 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Research Article Experimental

More information

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling Enhancement using Herringbone wavy & Smooth Wavy fin Exchanger for Hydraulic Oil Cooling 1 Mr. Ketan C. Prasadi, 2 Prof. A.M. Patil 1 M.E. Student, P.V.P.I.T.,Budhagaon,Sangli AP-India 2 Associate Professor,

More information

HEAT TRANSFER COEFFICIENT ENHANCEMENT IN NATURAL CONVECTION FROM HORIZONTAL RECTANGULAR FIN ARRAYS WITH PERFORATIONS

HEAT TRANSFER COEFFICIENT ENHANCEMENT IN NATURAL CONVECTION FROM HORIZONTAL RECTANGULAR FIN ARRAYS WITH PERFORATIONS International Journal of Mechanical Engineering and Technology (IJMET) Volume 10, Issue 01, January 2019, pp. 306 315, Article ID: IJMET_10_01_031 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=10&itype=1

More information

Experimental Study And CFD Based Simulation of Closed Loop Pulsating Heat Pipe Using of Refrigerants (R-134a)

Experimental Study And CFD Based Simulation of Closed Loop Pulsating Heat Pipe Using of Refrigerants (R-134a) International OPEN ACCESS Journal Of Modern Engineering Research (IJMER) Experimental Study And CFD Based Simulation of Closed Loop Pulsating Heat Pipe Using of Refrigerants (R-134a) Monika Tiwari 1, Dr.

More information

Experimental Comparison of Natural Convection Heat Transfer from a Blackened V-Fin Array

Experimental Comparison of Natural Convection Heat Transfer from a Blackened V-Fin Array International Journal of Modern Studies in Mechanical Engineering (IJMSME) Volume 4, Issue 1, 2018, PP 11-16 ISSN 2454-9711 (Online) DOI: http://dx.doi.org/10.20431/2454-9711.0401002 www.arcjournals.org

More information

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2 Modern Applied Science; Vol. 9, No. 13; 2015 ISSN 1913-1844 E-ISSN 1913-1852 Published by Canadian Center of Science and Education The Design of a Shell-Tube Heat Exchanger as Evaporator an Absorption

More information

A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS

A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS V. BHOGESWARA RAO Research Scholar Email:pallivayala@gmail.com Dr. S. CHAKRADHAR GOUD Principal, Sri Sarada Institute of Science and Technology

More information

A REVIEW ON HEAT TRANSFER ENHANCEMENT BY PASSIVE METHODS

A REVIEW ON HEAT TRANSFER ENHANCEMENT BY PASSIVE METHODS A REVIEW ON HEAT TRANSFER ENHANCEMENT BY PASSIVE METHODS Mr. Tejas Sonawane 1, Mr. Prafulla Patil 1, Mr. Abhay Chavhan 1, Prof. B.M.Dusane 2 1UG Student, Department of Mechanical Engineering, 2Assistant

More information

Performance Analysis Of Double Inclination Ribbed Solar Air Heater Rectangular Duct By Liquid Crystal Thermography

Performance Analysis Of Double Inclination Ribbed Solar Air Heater Rectangular Duct By Liquid Crystal Thermography Performance Analysis Of Double Inclination Ribbed Solar Air Heater Rectangular Duct By Liquid Crystal Thermography Amit Kumar Gautam¹, Dr. J. L. Bhagoria² ¹M.Tech. Scholar, Mechanical Engineering, ²Professor,

More information

A Review on Comparative Study of Thermal Performance of Artificially Roughened Solar Air Heaters

A Review on Comparative Study of Thermal Performance of Artificially Roughened Solar Air Heaters A Review on Comparative Study of Thermal Performance of Artificially Roughened Solar Air Heaters Ashwini Kumar 1, Mahmood Alam 2 1 Mechanical Engineering Department, N.I.T., Jamshedpur, India-831014 2

More information

Thermal Performance of a Loop Thermosyphon

Thermal Performance of a Loop Thermosyphon Tamkang Journal of Science and Engineering, Vol. 13, No. 3, pp. 281 288 (2010) 281 Thermal Performance of a Loop Thermosyphon Shung-Wen Kang*, Meng-Chang Tsai, Chih-Sheng Hsieh and Jian-You Chen Department

More information

A Review of Electro Thermal Cooling Systems with Heat Sink

A Review of Electro Thermal Cooling Systems with Heat Sink A Review of Electro Thermal Cooling Systems with Heat Sink Dr. Ashwini Kumar, Ravi Kumar, Dr. Arun Kumar Behura Abstract All electronic devices generate heat due to the current flow through them. Unless

More information

Thermal Analysis of Concentric Tube Heat Exchanger Using Louvered Strip Inserts

Thermal Analysis of Concentric Tube Heat Exchanger Using Louvered Strip Inserts Thermal Analysis of Concentric Tube Heat Exchanger Using Louvered Strip Inserts Anoop P S 1, N. Sreenivasalu Reddy 2 1 PG scholar, Raja Rajarajeswari College of Engineering, Bangalore-560074, Karnataka,

More information

Design, Development & Testing of Double Pipe Heat Exchanger With Heat Transfer Enhancement Liners

Design, Development & Testing of Double Pipe Heat Exchanger With Heat Transfer Enhancement Liners Volume 2, Issue 1, January 2017 ISSN (online): 2456-0006 International Journal of Science Technology Management and Research Available online at: Design, Development & Testing of Double Pipe Heat Exchanger

More information

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers Ashraf A 1, Mohammed Shan N 2, Thoufeeq Azad 3, Bibin S4, Arun S 5 1-4 Students, 5 Assistant Professor Department of

More information

Global Journal of Engineering Science and Research Management

Global Journal of Engineering Science and Research Management EXPERIMENTAL AND THEORETICAL STUDY OF MINIATURE VAPOR COMPRESSION CYCLE USING MICROCHANNEL CONDENSER Issam M. Ali Aljubury*, Ahmed Q. Mohammed, Marwa S. Neama * Mechanical Eng. Dept. College of Engineering,

More information

Solar air heater duct having triangular protrusions As roughness elements on absorber plate

Solar air heater duct having triangular protrusions As roughness elements on absorber plate Solar air heater duct having triangular protrusions As roughness elements on absorber plate A. Nagaraju 1, B. Chnadramohan Reddy 2 1,2 Department of Mechanical Engineering, Jawaharlal Nehru Technological

More information

Experimental Investigation of Tube Configuration for a Surface Condenser

Experimental Investigation of Tube Configuration for a Surface Condenser Experimental Investigation of Tube Configuration for a Surface Condenser Shrikant Subhash Chaudhari 1, T Mahender 2, Subramanyam Pavuluri 3 PG Student, Department of Mechanical Engineering, MLR Institute

More information

Optimized Finned Heat Sinks for Natural Convection Cooling of Outdoor Electronics

Optimized Finned Heat Sinks for Natural Convection Cooling of Outdoor Electronics Journal of Electronics and Information Science (2018) 3: 22-33 Clausius Scientific Press, Canada Optimized Finned Heat Sinks for Natural Convection Cooling of Outdoor Electronics Lian-Tuu Yeh, ASME Fellow

More information

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE Ram Mohan Gupta 1, Dr. Shatyendra Singh 2 Mr. Simant Srivastava 3 1 Mechanical Engineering, Uttarakhand

More information

Raman et al., International Journal of Advanced Engineering Technology E-ISSN

Raman et al., International Journal of Advanced Engineering Technology E-ISSN Research Paper EFFECT OF ELLIPTICAL INCLINED DIMPLES ON NUSSELT NUMBER AND FRICTION FACTOR FOR ARTIFICIALLY ROUGHENED DUCT OF SOLAR AIR HEATERS Raman Kumar a, Harvinder Lal b Address for Correspondence

More information

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12 EXPERIMENTAL ANALYSIS OF THE EFFECT OF FIN GEOMETRY ON HEAT TRANSFER RATE THROUGH THE REFRIGERATOR CONDENSER ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

More information

ANALYSING THE EFFECTIVENESS OF THE HEAT EXCHANGER BY INCREASING OVERALL HEAT TRANSFER COEFFICIENT

ANALYSING THE EFFECTIVENESS OF THE HEAT EXCHANGER BY INCREASING OVERALL HEAT TRANSFER COEFFICIENT ANALYSING THE EFFECTIVENESS OF THE HEAT EXCHANGER BY INCREASING OVERALL HEAT TRANSFER COEFFICIENT Mazhar Mumbaiwala 1, Rahul Panjwani 2, Rishikesh Shulav 3, Shashwat Budholia 4, Anshu Kumar 5 1,2,3,4UG

More information

THERMOHYDRAULIC PERFORMANCE OF AN EQUILATERAL TRIANGULAR DUCT WITH ARTIFICIAL ROUGHNESS USED IN SOLAR AIR HEATER

THERMOHYDRAULIC PERFORMANCE OF AN EQUILATERAL TRIANGULAR DUCT WITH ARTIFICIAL ROUGHNESS USED IN SOLAR AIR HEATER THERMOHYDRAULIC PERFORMANCE OF AN EQUILATERAL TRIANGULAR DUCT WITH ARTIFICIAL ROUGHNESS USED IN SOLAR AIR HEATER GAURAV BHARADWAJ 1, VARUN 2 & AVDHESH SHARMA 3 1,2&3 Mechanical Engineering dept. National

More information

Modified Air Cooler with Split Cooling Unit

Modified Air Cooler with Split Cooling Unit Modified Air Cooler with Split Cooling Unit Nishant Dhanore 1, Krishna Shrivastava 2 1 SSBT s College of Engineering and Technology, Jalgaon (M.S.), India 2 Associate Professor, Mech. Engg. Dept. SSBT

More information

Heat Transfer in Evacuated Tubular Solar Collectors

Heat Transfer in Evacuated Tubular Solar Collectors Heat Transfer in Evacuated Tubular Solar Collectors Graham L. Morrison, Indra Budihardjo and Masud Behnia School of Mechanical and Manufacturing Engineering University of New South Wales Sydney 2052 Australia

More information

Design, Development and Experimental Investigation of Volumetric Air Receiver

Design, Development and Experimental Investigation of Volumetric Air Receiver www.ierjournal.org International Engineering Research Journal (IERJ) Special Issue 2 Page 4109-4113 ISSN 2395-1621 ISSN 2395-1621 Design Development and Experimental Investigation of Volumetric Air Receiver

More information

a Heat Exchanger using FEA Tool

a Heat Exchanger using FEA Tool A Review on Optimal Design of Single Tube in a Heat Exchanger using FEA Tool Roshan V. Marode Abstract:- The performance of heat exchangers can be improved to perform a certain heat-transfer duty by heat

More information

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater Gurpreet Singh and Satwant Singh Lala Lajpat Rai Institute of Engineering and Technology, Moga (Punjab) 142001 Abstract : Artificial

More information

Finned Heat Sinks for Cooling Outdoor Electronics under Natural Convection

Finned Heat Sinks for Cooling Outdoor Electronics under Natural Convection Finned s for Cooling Outdoor Electronics under Natural Convection Lian-Tuu Yeh, Ph D & PE Thermal Consultant, Dallas, TX, 75252 USA Abstract For tower or poled mounted electronics, the heat sink weight

More information

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology IJIRST International Journal for Innovative Research in Science & Technology Volume 1 Issue 11 April 2015 ISSN (online): 2349-6010 CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

More information

Enhancement of Heat Exchanger Performance by the Extended Surfaces-Fins

Enhancement of Heat Exchanger Performance by the Extended Surfaces-Fins Enhancement of Heat Exchanger Performance by the Extended Surfaces-Fins Piyush Kumar Kashyap 1, priyanka jhavar 2 1 sri satya sai, College of engineering& science, Sheore, 466001 Abstract: 2 sri satya

More information

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger Abstract Shoeb J. Inamdar 1 H.S. Farkade 2 M. Tech student. (Thermal Engineering) 1, Asst. Professor 2 Department of Mechanical

More information

2. HEAT EXCHANGERS MESA

2. HEAT EXCHANGERS MESA 1. INTRODUCTION Multiport minichannel and microchannel aluminium tubes are becoming more popular as components in heat exchangers. These heat exchangers are used in various industrial applications and

More information

Design and Development of Water Cooled Condenser for Domestic Refrigerator

Design and Development of Water Cooled Condenser for Domestic Refrigerator Design and Development of Water Cooled Condenser for Domestic Refrigerator Anil S. Patil Research PG Student, GF s Godavari College of Engineering, Jalgaon Dr. Atul A Patil Assot. Prof. GF s Godavari College

More information

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger IJSTE - International Journal of Science Technology & Engineering Volume 1 Issue 12 June 2015 ISSN (online): 2349-784X Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger N. Manigandan

More information

Jurnal UMP Social Sciences and Technology Management Vol. 3, Issue. 3,2015

Jurnal UMP Social Sciences and Technology Management Vol. 3, Issue. 3,2015 The Design of a Heat Exchanger Shell - Tube as Evaporator an Absorption Chiller Cycle to Reduce the Temperature of the Air Entering Diesel Engine Heavy Loads 75% And 50% of the Engine Part Seyyede Sepideh

More information

Modelling Of The Single Staggered Wire And Tube Heat Exchanger

Modelling Of The Single Staggered Wire And Tube Heat Exchanger Modelling Of The Single Staggered Wire And Tube Heat Exchanger I Made Arsana Department of Chemical Engineering, Sepuluh Nopember Institute of Technology (ITS), Surabaya, East Java, Indonesia. Kusno Budhikardjono

More information

Heat Transfer Enhancement in Shell and Tube Condenser

Heat Transfer Enhancement in Shell and Tube Condenser International Journal of Current Engineering and Technology E-ISSN 2277 4106, P-ISSN 2347 5161 2017 INPRESSCO, All Rights Reserved Available at http://inpressco.com/category/ijcet Research Article Heat

More information

1, 2

1, 2 HEAT TRANSFER ENHANCEMENT BY SWIRL FLOW DEVICES Tarique Anwar Qureshi 1, Anil Singh Yadav 2 1 Assistant Professor, Technocrats Institute of Technology and Science (TITS), Bhopal (M.P) 2 Professor, Lakshmi

More information

Performance of Shell and Tube Heat Exchanger under Varied Operating Conditions

Performance of Shell and Tube Heat Exchanger under Varied Operating Conditions Performance of Shell and Tube Heat Exchanger under Varied Operating Conditions N. Prabhu Kishore 1, N. Alekhya 2, J. Ugandhar 3 Asst. Professor, Department of Mechanical Engineering, MLR Institute of Technology,

More information

Effect of Louvered Strips on Heat Transfer in a Concentric Pipe Heat Exchanger

Effect of Louvered Strips on Heat Transfer in a Concentric Pipe Heat Exchanger Effect of Louvered Strips on Heat Transfer in a Concentric Pipe Heat Exchanger Somsak Pethkool 1, Smith Eiamsa-ard, Artit Ridluan and Pongjet Promvonge 1,* 1 Department of Mechanical Engineering, Faculty

More information

[Jhansi, 5(10): October 2018] ISSN DOI /zenodo Impact Factor

[Jhansi, 5(10): October 2018] ISSN DOI /zenodo Impact Factor GLOBAL JOURNAL OF ENGINEERING SCIENCE AND RESEARCHES PERFORMANCE ANALYSIS OF VCR SYSTEM WITH TWISTED TAPE CONDENSER BY USING R134a REFRIGERANT Chidige Jhansi* 1 & Dr.Smt.G.Prasanthi 2 *1 PG Research Scholar

More information

I. INTRODUCTION. Types of Fins:

I. INTRODUCTION. Types of Fins: International Journal of Advances in Applied Science and Engineering (IJAEAS) ISSN (P): 2348-1811; ISSN (E): 2348-182X Vol. 3, Issue 2, May 2016,19-24 IIST HEAT TRANSFER ANALYSIS ON RECTANGLE AND TRAPEZOIDAL

More information

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System Enhancement of COP by Using Spiral and Microchannel instead of conventional of VCR System 1 P.G. Lohote, 2 Dr.K.P. Kolhe. 1 P.G. Student, 2 Professor. 1,2 Department of Mechanical Engineering, JSPM s,

More information

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1 HEFAT27 5 th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp PERFORMANCE ANALYSIS OF AIR-COOLED CONDENSER USING MICRO-FIN TUBES P.A.Patil

More information

DESIGN AND ANALYSIS OF PIPE HEAT EXANGERS WITH INSIDE FINS

DESIGN AND ANALYSIS OF PIPE HEAT EXANGERS WITH INSIDE FINS DESIGN AND ANALYSIS OF PIPE HEAT EXANGERS WITH INSIDE FINS Helan Jacob.J 1,Chandra Mohan.B 2,Palanisamy.S 3 1, P.G. Scholars, Department ofthermal Engineering, Oxford Engineering college,pratiyur, Trichy.

More information

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way 1 CHAPTER I INTRODUCTION In the modern life, electronic equipments have made their way in to practically every part, which is from electronic gadgets to high power computers. Electronic components have

More information

EFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES

EFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES International Journal of Mechanical and Materials Engineering (IJMME), Vol. 2 (2007), No. 2, 109--117. EFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES M. Hasanuzzaman

More information

Compression of Fins pipe and simple Heat pipe Using CFD

Compression of Fins pipe and simple Heat pipe Using CFD Compression of Fins pipe and simple Heat pipe Using CFD 1. Prof.Bhoodev Mudgal 2. Prof. Gaurav Bhadoriya (e-mail-devmudgal.mudgal@gmail.com) ABSTRACT The aim of this paper is to identify the advantages

More information

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5 IJAET International Journal of Application of Engineering and Technology ISSN: 2395-3594 Vol-1 No.-2 CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys

More information

Analysis of CPU cooling using liquid with different type of heat sinks

Analysis of CPU cooling using liquid with different type of heat sinks Analysis of CPU cooling using liquid with different type of heat sinks #1 Mr. Deep N. Surve, #2 Mr. Prafulla R. Hatte #1 MIT Academy of Engineering, Savitribai Phule Pune University, Pune, Maharashtra,

More information

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger International Journal of ChemTech Research CODEN( USA) IJCRGG ISSN 0974-4290 Vol.5, No.2, pp 925-934, April-June 2013 ICGSEE-2013[14th 16th March 2013] International Conference on Global Scenario in Environment

More information

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection RESEARCH ARTICLE OPEN ACCESS Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection Tanuj Kumar Sahu 1, Vishal Gupta 2, Ajay Kumar Singh 3

More information

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System A D Parekh, and P R Tailor Abstract Because of damaging effect of CFC refrigerants on stratospheric

More information

Sant Gadge Baba Amravati University. Amravati, Maharashtra, India, Maharashtra 2

Sant Gadge Baba Amravati University. Amravati, Maharashtra, India, Maharashtra 2 2018 IJSRST Volume 4 Issue 8 Print ISSN: 2395-6011 Online ISSN: 2395-602X Themed Section: Science and Technology Heat Transfer Characteristic of Spiral Heat Exchanger: Effect of Reynolds Number on Heat

More information

Heat Exchanger Joule-Thomson Transient Cryogenic Refrigeration. Iranian Journal of Chemical Engineering Vol. 14, No. 3 (Summer 2017), IAChE

Heat Exchanger Joule-Thomson Transient Cryogenic Refrigeration. Iranian Journal of Chemical Engineering Vol. 14, No. 3 (Summer 2017), IAChE Iranian Journal of Chemical Engineering Vol. 14, No. 3 (Summer 2017), IAChE Transient Thermal Study of Recuperative Tube in Tube Heat Exchanger Operating in Refrigeration System Using Experimental Test

More information

Effects of mass flow rate in terms of pressure drop and heat transfer characteristics

Effects of mass flow rate in terms of pressure drop and heat transfer characteristics Merit Research Journal of Environmental Science and Toxicology Vol. 1(1) pp. 005-011, March, 2013 Available online http://www.meritresearchjournals.org/est/index.htm Copyright 2013 Merit Research Journals

More information

LAB EQUIPMENT DETAILS

LAB EQUIPMENT DETAILS DEPARTMENT OF MECHANICAL ENGINEERING LAB EQUIPMENT DETAILS S. N o Name of the Equipment Manufacturer Equipment Photo Description Applications Cost of the Equipment 1 Guarded plate The consists of main

More information

Performance Study of Triple Concentric Pipe Heat Exchanger

Performance Study of Triple Concentric Pipe Heat Exchanger Performance Study of Triple Concentric Pipe Heat Exchanger #1 Pravin M. Linge, #2 A. B. Korane, #3 V. N. Kapatkar #123 Mechanical Engineering Department, Sinhgad College of Engineering, SPPU, Pune, India

More information

EFFECTIVE UTILIZATION OF SOLAR ENERGY IN AIR DRYER

EFFECTIVE UTILIZATION OF SOLAR ENERGY IN AIR DRYER International Journal of Mechanical and Production Engineering Research and Development (IJMPERD) ISSN 2249-6890 Vol. 3, Issue 1, Mar 2013, 133-142 TJPRC Pvt Ltd. EFFECTIVE UTILIZATION OF SOLAR ENERGY

More information

ENSC 388: Engineering Thermodynamics and Heat Transfer

ENSC 388: Engineering Thermodynamics and Heat Transfer ENSC 388: Engineering Thermodynamics and Heat Transfer Experiment 3: Free and Forced Convection Objective Determination of heat transfer coefficient for free and forced convection for different geometries.

More information

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid Simulation Analysis of Compression Refrigeration Cycle with Different Refrigerants P.Thangavel, Dr.P.Somasundaram, T.Sivakumar, C.Selva Kumar, G.Vetriselvan Abstract --- In this analysis, the performance

More information

A REVIEW ON HEAT EXCHANGER

A REVIEW ON HEAT EXCHANGER A REVIEW ON HEAT EXCHANGER Shambhu Kumar Rai 1, Parmeshwar Dubey 2 1 Assistant Professor, MED, Vadodara Institute of Engineering Vadodara, Gujarat, India. 2 Training Officer MED, Anjali Foundation Gurgaon,

More information

Characterization of a Heat Sink with Embedded Heat Pipe with Variable Heat Dissipating Source Placement for Power Electronics Applications

Characterization of a Heat Sink with Embedded Heat Pipe with Variable Heat Dissipating Source Placement for Power Electronics Applications Characterization of a Heat Sink with Embedded Heat Pipe with Variable Heat Dissipating Source Placement for Power Electronics Applications Neda Mansouri, Cliff Weasner and Ahmed Zaghlol Mersen Canada Toronto

More information

Assistant Professor),( Professor), Department of Mechanical Engg., B.I.T. Sindri 3. Professor, Department of Mechanical Engg., N.I.T.

Assistant Professor),( Professor), Department of Mechanical Engg., B.I.T. Sindri 3. Professor, Department of Mechanical Engg., N.I.T. Experimental study of Collector heat removal factor and Collector efficiency factor of flat-plate solar Air Heater having roughened (Rhombus shape) absorber plate 1 Pankaj Kumar, 2 Dr. S.C.Roy, 3 Dr.M.K.Paswan

More information

EXPERIMENTAL ANALYSIS OF TIP CLEARANCE AND CHORD LENGTH FOR OPTIMUM DESIGN OF AXIAL FLOW FAN IN AIR COOLED HEAT EXCHANGER

EXPERIMENTAL ANALYSIS OF TIP CLEARANCE AND CHORD LENGTH FOR OPTIMUM DESIGN OF AXIAL FLOW FAN IN AIR COOLED HEAT EXCHANGER EXPERIMENTAL ANALYSIS OF TIP CLEARANCE AND CHORD LENGTH FOR OPTIMUM DESIGN OF AXIAL FLOW FAN IN AIR COOLED HEAT EXCHANGER Sushil Kumar 1, Dr. V.N.Bartaria 2 1 M.Tech Scholar, 2 Professor & HOD Dept. of

More information

American International Journal of Research in Science, Technology, Engineering & Mathematics

American International Journal of Research in Science, Technology, Engineering & Mathematics American International Journal of Research in Science, Technology, Engineering & Mathematics Available online at http://www.iasir.net ISSN (Print): 2328-3491, ISSN (Online): 2328-358, ISSN (CD-ROM): 2328-3629

More information

Shalaby Institute of Fire Protection Heyrothsberge, Germany.

Shalaby Institute of Fire Protection Heyrothsberge, Germany. International Water Mist Conference November 3-4, 2010, Prague, Czech Republic The Influence of Droplet Size of Water Mist on Extinguishment Fire Plume Dr.Hemdan Shalaby Institute of Fire Protection Heyrothsberge,

More information

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System Kwanghee Seo 1) and Taewan Kim 2)* 1) KEPCO Engineering & Construction Company. INC., 269 Hyeoksin-ro,

More information

MINIATURE HEAT TRANSPORT SYSTEMS WITH LOOP HEAT PIPES

MINIATURE HEAT TRANSPORT SYSTEMS WITH LOOP HEAT PIPES IV Minsk International Seminar Heat Pipes, Heat Pumps, Refrigerators Minsk, Belarus, September 4-7, MINIATURE HEAT TRANSPORT SYSTEMS WITH LOOP HEAT PIPES V. Kiseev, A. Belonogov Ural State University,

More information

Design and Fabrication of Solar Air Heater to Increase Heat Transfer Rate using Artificial Roughness

Design and Fabrication of Solar Air Heater to Increase Heat Transfer Rate using Artificial Roughness Design and Fabrication of Solar Air Heater to Increase Heat Transfer Rate using Artificial Roughness Anjali Vyas 1, Sanchit Gupta 2, Amankumar Jaiswal 3, Chaitanya Jire 4, Aditya Joshi 5 1Assistant Professor,

More information

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger Shoeb Inamdar 1, H. S. Farkade 2 P.G. Student, Department of Mechanical Engineering, Govt. College of Engg. Amravati. Maharashtra,

More information

To investigate the surface properties for increasing efficiency of solar water heater

To investigate the surface properties for increasing efficiency of solar water heater Journal of Physics: Conference Series OPEN ACCESS To investigate the surface properties for increasing efficiency of solar water heater To cite this article: A Hai and Qurat-ul-Ain 2013 J. Phys.: Conf.

More information

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 4, 2011

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 4, 2011 Performance evaluation of two stage indirect/direct evaporative cooler with alternative shapes and cooling media in direct stage Kulkarni.R.K 1, Rajput S.P.S 2 1 SVPM College of Engineering, Malegaon(bk),

More information

Agitation and Mixing

Agitation and Mixing Agitation and Mixing Agitation: Agitation refers to the induced motion of a material in a specified way, usually in a circulatory pattern inside some sort of container. Purpose is to make homogeneous phase.

More information

Theoritical Analysis For Miniature Vapor Compression Cycle Performance Using Microchannel And Finned Tube Condenser

Theoritical Analysis For Miniature Vapor Compression Cycle Performance Using Microchannel And Finned Tube Condenser Theoritical Analysis For Miniature Vapor Compression Cycle Performance Using Microchannel And Finned Tube Condenser Issam Mohammed Ali Ahmed Qasim Mohammed Marwa Sallah Neama Mechanical Eng. Dept Air-

More information

Induction heating with the ring effect for injection molding plates

Induction heating with the ring effect for injection molding plates Induction heating with the ring effect for injection molding plates article info abstract Available online 8 March 2012 Keywords: Dynamic mold temperature control Induction heating Inductor design Induction

More information

International Journal of Engineering Research & Technology (IJERT) ISSN: Vol. 2 Issue 10, October

International Journal of Engineering Research & Technology (IJERT) ISSN: Vol. 2 Issue 10, October Thermodynamic and Hydrodynamic Performance of Double Pipe Heat Exchanger with Bended Strips Prof. S. S. Rajigare, Prof. H. M. Dange Assistant professor at KJCOEMR Pune, Professor PVPIT Sangli Abstract

More information

Experimental Research and CFD Simulation on Microchannel Evaporator Header to Improve Heat Exchanger Efficiency

Experimental Research and CFD Simulation on Microchannel Evaporator Header to Improve Heat Exchanger Efficiency Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2006 Experimental Research and CFD Simulation on Microchannel Evaporator Header

More information

Experimental Investigation of Heat Transfer Enhancement from Waveform Pin-Fins

Experimental Investigation of Heat Transfer Enhancement from Waveform Pin-Fins Experimental Investigation of Heat Transfer Enhancement from Waveform Pin-Fins Hajare Swapnali R. 1, Dr. Kore Sandeep S. 2 M.E. student, Dept. of Mechanical Engineering, Genba Sopanrao Moze College of

More information

Experimental Investigations on Packed Bed Solar Air Heater

Experimental Investigations on Packed Bed Solar Air Heater Current World Environment Vol. 6(1), 151-157 (2011) Experimental Investigations on Packed Bed Solar Air Heater M.K. LALJI*, R.M. SARVIYA¹ and J.L. BHAGORIA¹ *Department of Technical Education and Skill

More information

ENHANCEMENT OF HEAT TRANSFER IN DOUBLE PIPE HEAT EXCHANGER USING TWISTED TAPES

ENHANCEMENT OF HEAT TRANSFER IN DOUBLE PIPE HEAT EXCHANGER USING TWISTED TAPES ENHANCEMENT OF HEAT TRANSFER IN DOUBLE PIPE HEAT EXCHANGER USING TWISTED TAPES Bhusare Deepak 1, Dighe Roshan 2,Gadhe Vaibhav 3,Shinde Rahul 4, Prof.Sawant S.G. 5 1 Student, Mechanical Department, SND

More information

Effect of Placement of Footing on Stability of Slope

Effect of Placement of Footing on Stability of Slope Scientific Journal of Impact Factor (SJIF) : 3.134 ISSN (Print) : 2348-6406 ISSN (Online): 2348-4470 International Journal of Advance Engineering and Research Development Effect of Placement of Footing

More information

FABRICATING A HEAT PIPE STRUCTURE WITHIN A RADIATING PLATE FOR ELECTRONICS FAN-LESS COOLING

FABRICATING A HEAT PIPE STRUCTURE WITHIN A RADIATING PLATE FOR ELECTRONICS FAN-LESS COOLING Journal of Marine Science and Technology, Vol. 18, No. 3, pp. 419-423 (2010) 419 FABRICATING A HEAT PIPE STRUCTURE WITHIN A RADIATING PLATE FOR ELECTRONICS FAN-LESS COOLING Chun-Sheng Yu*, Shung-Wen Kang*,

More information

Experimental Analysis on Effect of Design Parameters on the Performance of Single Loop Pulsating Heat Pipe

Experimental Analysis on Effect of Design Parameters on the Performance of Single Loop Pulsating Heat Pipe Experimental Analysis on Effect of Design Parameters on the Performance of Single Loop Pulsating Heat Pipe Someshwar S. Bhakre 1, Md. Rafik Sajjadahmad Choudhari 2 1, 2 PG Scholar, Mechanical Engineering

More information

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions Joint 18th IHPC and 12th IHPS, Jeju, Korea, June 12-16, 2016 Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions Jens Weyant

More information

Design Based Comparative Study of Several Condensers Komal B. Dabhi 1, Prof. S. B. Thakore 2 1 Chemical Engg. Dept., L. D. College of Engineering, Ahmedabad 380015 2 Chemical Engg. Dept., L. D. College

More information

Enhancement of Round Tube and Flat Tube- Louver Fin Heat Exchanger Performance Using Deluge Water Cooling

Enhancement of Round Tube and Flat Tube- Louver Fin Heat Exchanger Performance Using Deluge Water Cooling Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2012 Enhancement of Round Tube and Flat Tube- Louver Fin Heat Exchanger Performance

More information

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET) AN EXPERIMENTAL STUDY OF HEAT TRANSFER IN A CORRUGATED PLATE HEAT EXCHANGER

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET) AN EXPERIMENTAL STUDY OF HEAT TRANSFER IN A CORRUGATED PLATE HEAT EXCHANGER INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET) International Journal of Mechanical Engineering and Technology (IJMET), ISSN 0976 6340(Print), ISSN 0976 6340 (Print) ISSN 0976 6359

More information

Numerical study of heat pipe application in heat recovery systems

Numerical study of heat pipe application in heat recovery systems Numerical study of heat pipe application in heat recovery systems *Song Lin, John Broadbent, Ryan McGlen Thermacore Europe, 12 Wansbeck Business Park Ashington, Northumberland NE3 QW, UK E-mail: song.lin@thermacore.com

More information

Greek Symbol η collector efficiency Rim angle

Greek Symbol η collector efficiency Rim angle IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 09, 2015 ISSN (online): 2321-0613 Experimental Investigation of Parabolic Trough Collector Solar Air Heater Patel Mayur

More information

International Journal of Advance Engineering and Research Development

International Journal of Advance Engineering and Research Development Scientific Journal of Impact Factor (SJIF): 5.71 e-issn (O): 2348-4470 p-issn (P): 2348-6406 International Journal of Advance Engineering and Research Development International Conference on Creativity

More information

Experimentation of Heat Pipe Used In Nano-Fluids

Experimentation of Heat Pipe Used In Nano-Fluids Experimentation of Heat Pipe Used In Nano-Fluids 1 Prashant Shinde, 2 Vinod Shinde, 3 Rajiv Talape, 4 D.N. Korade 1,2,3,4 Department of Mechanical Engineering, Sinhgad Institute of Technology & Science,

More information

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY A PATH FOR HORIZING YOUR INNOVATIVE WORK EXPERIMENTAL INVESTIGATION OF HELICAL COIL AND STRAIGHT TUBE HEAT EXCHANGER 1.

More information

EXPERIMENTAL AND THEORTICAL STUDY OF THE THERMAL PERFORMANCE OF HEAT PIPE HEAT EXCHANGER

EXPERIMENTAL AND THEORTICAL STUDY OF THE THERMAL PERFORMANCE OF HEAT PIPE HEAT EXCHANGER International Journal of Mechanical Engineering and Technology (IJMET) Volume 7, Issue 3, May June 2016, pp.102 111, Article ID: IJMET_07_03_009 Available online at http://www.iaeme.com/ijmet/issues.asp?jtype=ijmet&vtype=7&itype=3

More information

Performance of Water-in-Glass Evacuated Tube Solar Water Heaters

Performance of Water-in-Glass Evacuated Tube Solar Water Heaters Performance of Water-in-Glass Evacuated Tube Solar Water Heaters I. and G.L.Morrison School of Mechanical and Manufacturing Engineering University of New South Wales Sydney 2052 AUSTRALIA E-mail: g.morrison@unsw.edu.au

More information

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat Abstract Axial flow fans, while incapable of developing high pressures, they are well suitable for handling large volumes of air at relatively

More information