Modular Hi-Rise Series FAN COIL TECHNICAL CATALOG

Size: px
Start display at page:

Download "Modular Hi-Rise Series FAN COIL TECHNICAL CATALOG"

Transcription

1 Cost Effective Solution Easy to Install/Service Variety of Sizes/Applications MY MAY/MBY MPY

2 2 Table of Contents Portfolio 4- Features and Benefits 6-2 Product Application Unit Model Key 4- Ratings and Listings 6-8 Fan Performance Curves 9 Motor ata Sound Power ata 2 Electric Heating 24- Submittal ata 6-42 Standard Features and Options International Environmental Corporation (IEC) works continually to improve its products. As a result, the design and specifications of each product may be changed without notice and may not be as described herein. Please contact IEC for information regarding current design and product specifications. Statements and other information contained herein are not express warranties and do not form the basis of any bargain between the parties but are merely IEC s opinion or commendation of its products. Manufacturer s standard limited warranty applies. 2

3 MPY Modular Hi-Rise Concealed 00 CFM to 200 CFM The Concealed Modular (MPY) fan coil unit, International Environmental Corporation s (IEC) premier Modular unit, is designed for concealed applications in corners or along room walls. Once installed, only the thermostat control, supply grille and decorative return air panel of the MPY are visible in the room. The return air panel provides easy access to all internal components. Standard MPY units are provided with a galvanized finish on the cabinet and a powdercoat paint finish on the return air panel. MY Modular Hi-Rise Cabinet 00 CFM to 200 CFM The Exposed Modular (MY) fan coil unit is designed for applications where concealed installation is not possible or practical. The slim, attractivelystyled cabinet of the MY blends with all types of decor. MY units feature a double-deflection supply grille, an integral return air panel and a unitmounted thermostat control. Standard MY units are provided with a powdercoat paint finish. finish on the return air panel. MAY/MBY Modular Hi-Rise Concealed itto 00 CFM to 200 CFM The itto Concealed Modular (MAY/ MBY) fan coil system is designed for installations where two units share riser piping in the separation wall between two rooms but are equipped with individual valves, supply and return grilles, and controls. The itto Concealed Modular unit is shipped factory assembled for additional installed cost savings. Standard itto units are provided with a galvanized finish on the cabinet and a powder-coat paint MMY/MSY Modular Hi-Rise Concealed Primary/Secondary 00 CFM to 200 CFM The Primary/Secondary Modular (MMY/MSY) fan coil unit is ideal for applications where design restricts the installation of IEC s itto or Siamese itto systems. With this configuration, field brazing is required to complete the piping between two separate Modular Hi-Rise fan coil units. Standard MMY/MSY units are provided with a galvanized finish on the cabinet and a powder-coat paint finish on the return air panel.

4 Versatility In esign and Installation Modular Hi-Rise fan coil systems offer versatile unit arrangements made possible as a factory-assembled and integrated package. They are designed to be of low visual impact in the room, often positioned in a corner, along the perimeter wall or as part of a partition separating two areas. They can also stand alone in an exposed configuration. The itto is designed for those applications where the Hi-Rise fan coils are part of a partition separating two areas. The itto consists of two units complete with separate valves and controls, which are shipped factory-assembled with common risers. esign Features Field or factory-installed insulated water and condensate risers Swaged riser connection ouble-deflection supply air grille Galvanized steel cabinet Unit installed behind drywall Thermostat with quick-connect Powder-coat return air access panel Removable motor and blower assembly with quick-connect plug raw-through, 4-pipe coil* Filter Factory-installed control valves with quick-connect actuators Insulated drain pan with p-trap Control box with cover Removable acoustical service access panel (not shown) * Available applications are 2-pipe, 4-pipe (shown), 2-pipe auxiliary electric heat, and 2-pipe total electric heat. 4

5 Application Fit Exposed and concealed cabinets with 4 possible airflow configurations provide solutions for multiple applications. A variety of aesthetically pleasing return and supply grilles will blend with most décors. Thermostats are available as unit, surface, wall or AA mounted for ease of human interface. Units are specifically designed for quiet operation. esign Flexibility Easy to use computer rating program to speed up project design. Wide variety of coil configurations to match the heating and cooling loads of the space. Coils with different pressure drops to meet the needs of custom applications are also available. Standard motor/blower assemblies to meet the needs of applications where duct work is required. Customizable cabinetry is available for special applications. Ideal for new construction and renovation projects. Optional itto fan coil designed to serve two separate rooms using UL listed one-hour fire-rated riser chase. Multiple riser locations for total flexibility. Wide variety of valve packages factory installed to meet desired control specifications. Manual or motorized outside air dampers are available to meet ventilation requirements and reduce field labor. Several MERV rated filter media available to address IAQ requirements. Extensive offering of control options available. Wide variety of insulation material available to address IAQ concerns. Heavy galvanized or stainless steel drain pan with preformed rubber p-trap. Ease of Installation Units assembled at the factory in coordination with the jobsite construction schedule. Riser length is matched to the job specifications and pre-fabricated with the specified material. Risers are factory installed or shipped separately. Risers swaged to reduce field brazing labor and to ensure the integrity of the connections. rywall can be applied directly to the surface of the concealed unit with factory provided duct collars and drywall stops to ensure a high quality finished appearance. Control box at eye level for ease of field wiring and easy access. Ease of Service Filters are easily accessible by removing return air panel. Motor and blower are removable with quick-connect plug. Control box is easily accessible and at eye level. Quality and Safety Every unit tested and inspected at the factory for trouble free start-up. ETL listed AI certified

6 Versatile Unit Arrangement Options One of the unique traits of the Modular Hi-Rise fan coil system is the versatile unit arrangements possible with this factory-assembled, integrated package. When selecting the best unit design configuration for your specific single- or multi-story building, you are afforded the luxury of choosing from numerous unit arrangement options which achieve maximum efficiency while conserving floor space and reducing installation costs. Modular Hi-Rise fan coils are designed to be unobtrusive in the room and, thus, are often positioned in a corner, along a perimeter wall, as part of a partition separating two areas, or as a stand-alone unit in the exposed configuration. Modular Hi-Rise fan coils can be specified with up to three sidedischarge openings as well as a top discharge for ducted applications. Below are a few of the many arrangement possibilities of the Modular Hi-Rise fan coil system. Room B MPY Room A MAY Room A MBY Room B Closet Closet MAY MBY MAY Room A Room B MPY Room B Room A MBY Room A Room B MPY Room B Room A MPY MSY MMY LEGEN Room B Room A Room A Room B Exterior Wall Field Sheetrock IEC Sheetrock Separation or Utility Chase Modular Riser Unit Partition (or Separation) Wall Field-installed Piping ply Air urn Air 6

7 Versatile Standard Unit Arrangement Options The Modular Hi-Rise Series is available in a number of different unit configurations to fit most hi-rise retrofit applications. When selecting the best unit design configuration for a specific application, the footprint of the existing cabinet, as well as the stub-out location, will need to be considered to provide the best solution. These units are designed for a minimally disruptive retrofit to keep room downtime to a minimum and save on installation costs. Modular Hi-Rise fan coils are designed to be unobtrusive in the room and blend with a wide variety of decors. Units can be specified with up to two discharge openings, as well as a top discharge for ducted applications. Below are examples of the standard unit arrangement possibilities for the Modular Hi-Rise Replacement fan coil series. Single-side ply Top ply Only A 4 A 2 A 4 ply 2 H 6 H H K ply K ply K S S 6 S ply T T 6 T ply Single-side and Top ply M2 ply C2 4 ply C2 2 M C2 ply M2 Riser Location - Back Hi-Rise Cabinet Arrangement urn ply = Hot Water urn = Hot Water ply = rain = Cold Water urn = Cold Water ply Outside Air Locations: = Right-Front 2 = Left-Front = Right-Rear 4 = Left-Rear = Back-Right 6 = Back-Left Note: Front=urn Air Side (Varies with Arrangement) Rear=Opposite Front W2 ply W2 6 ply W2 NOTES:. Risers pictured are shown for reference purposes only and adhere to the IEC standard convention. 2. Riser supply-return configurations & temperature should be labeled prior to demolition, and must be verified prior to installation, as they may differ from the IEC standard convention. 7

8 Special Arrangement Options: Single-side ply Single-side and Top ply B 4 B B E2 ply E2 4 2 ply E2 E2 ply 2 C C C ply F2 ply F2 F2 ply G G G ply J2 6 ply J2 J2 ply 6 J J J ply N2 4 ply N2 2 N2 ply 4 2 P P 6 P ply S2 S2 ply 6 S2 ply ply V2 ply V2 ply Q Q Q V2 NOTES:. For special supply/return arrangement options, please contact IEC for pricing and availability. 2. Any special supply/return arrangement may effect sound and performance.. Risers pictured are shown for reference purposes only, and adhere to the IEC standard convention. 4. Riser supply-return configurations and temperatures should be labeled prior to demolition, and must be verified prior to installation, as they may differ from the IEC standard convention.. Special arrangements may require special supply grilles, baffling and lab testing to validate actual performance. Special Arrangement Options (Cont d on next page) 8

9 9 Modular Hi-Rise Series Q2 Q2 Q2 6 T2 T2 T2 ouble-side and Top ply B B B ply ply ply 2 4 C C C ply ply ply ply ply ply H H H ply ply ply 6 J J J ply ply ply Special Arrangement Options (Cont d): ouble-side ply A2 A2 A2 2 4 B2 B2 B G2 G2 G2 6 H2 H2 H2 K2 K2 K2 2 4 P2 P2 P2 Special Arrangement Options (Cont d on next page)

10 Special Arrangement Options (Cont d): Triple-side ply ouble-side and Top ply (Cont d) K ply ply K ply 4 2 K A A A ply Q Q ply Q ply G G G ply S S ply 6 S ply P P P ply T T ply T ply NOTES:. For special supply/return arrangement options, please contact IEC for pricing and availability. 2. Any special supply/return arrangement may affect sound and performance.. Risers pictured are shown for reference purposes only and adhere to the IEC standard convention. 4. Riser supply-return configurations and temperatures should be labeled prior to demolition, and must be verified prior to installation, as they may differ from the IEC standard convention.. Special arrangements may require special supply grilles, baffling and lab testing to validate actual performance. 0

11 Riser Material, Sizing and Insulation Because Modular Hi-Rise units are furnished with field or factory installed risers, the riser type, size and length, and insulation for each unit must be determined based on the position of the unit in the building. The chilled and hot water risers and condensate drain are available in a variety of diameters from /4" through 2-/2". See Mechanical Specifications section. All factory furnished risers and riser extensions, including condensate drains, are insulated for the full riser length to eliminate the need for field furnished insulation. Other materials to accommodate such critical specifications as riser expansion and between-the-floor fire proofing must be field furnished and installed by others. Consult the factory for special Applications. Riser sizing is normally based on the water flow requirements of each unit and the units above and below the unit in the riser column depending on the type of system being used. A common design criteria is to select the risers to limit water velocity at four to seven feet per second. Using this method, risers may be reduced in size as the water flow reduces from floor to floor. Uniform riser sizing may be used on shorter buildings where the additional riser expense would likely be offset by a greater savings in unit handling expense on the job. Riser Expansion MAIMUM WATER TEMPERATURE IFFERENCES (ºF) IEC s Modular Hi-Rise units are built to accommodate modest expansion of the external risers. Standard unit construction, including internal expansion loops, allows for a maximum of ±/4-inch of external riser expansion/contraction. This only allows for expansion between the unit and the riser. This allowance for the THERMAL EPANSION OF COPPER RISERS EPANSION (INCHES PER FOOT) movement by the internal piping structure is not intended to replace necessary expansion compensation devices that the consulting engineer may deem advisable for the external riser system. External riser expansion/contraction compensation and anchoring are the responsibility of the consulting engineer and the installing contractor.

12 PRESSURE ROP FT. WATER / 00 FT. OF RISER ¾ Inch Nominal Inch Nominal ¼ Inch Nominal ½ Inch Nominal 2 FPS 2 Inch Nominal FPS 2½ Inch Nominal 4 FPS FPS 6 FPS Inch Nominal 8 FPS 7 FPS Inch Nominal WATER FLOW RATE GPM 2

13 Code Items Unit Code 0 M P 02 Y A 04 Y Y Y A 04a C C Y 0 C 2 06 A 07 C P 4 UNIT VINTAGE SIZE COILS COILS w/electric HEAT MOTOR ARRANGEMENT CONTROLS MPY Modular Concealed MAY Modular Concealed (itto-a) MBY Modular Concealed (itto-b) MMY Modular Concealed (Primary) MSY Modular Concealed (Secondary) MY Modular Cabinet 0 00 CFM CFM CFM CFM CFM CFM Voltage C E F Type 2 Permanent Split Capacitor (PSC) A ECO4, -Spd w/adjust. Brd B ECO4, Proportional Fan (0-0VC/4-20mA) C ECO4, 4-Spd EVO Brd (SSRs) Board with Ramping Two-pipe Cooling and Heating or Four-pipe Cooling A Row B 4 Row R Row, AAV S 4 Row, AAV Four-pipe Heating Y None 6 Row Water Heating 7 2 Row Water Heating Coil Connection Y None S Same End Coil Construction Y Std S SS Wrapper SINGLE SUPPLY** ARR Code urn ply A Front Front B Front Right C Front Left Front Top OUBLE SUPPLY** Coil A Row B 4 Row Voltage C E F kw* B.00 C F.00 G 4.00 H.00 J 6.00 L 8.00 N 0.00 Y No Electric Heat Coil Construction Y Std S SS Wrapper ARR Code urn ply A2 Front Front/Right B2 Front Front/Left C2 Front Front/Top 2 Front Right/Left E2 Front Right/Top F2 Front Left/Top *** *** *** Voltage B 24 V C 20 V 208 V E 240 V F 277 V Note that kws depend on voltage and unit size. For additional codes check the price sheet. Consult factory for pricing. System/Thermostat Manual Fan Operation A Standard Unit Mount (Switch Only) Function Control G 2-Pipe Heat Only H 2-Pipe Cool Only J 2-Pipe Heat and Cool, MCO K 2-Pipe Heat and Cool, ACO L 2-Pipe Heat and Cool w/ Aux. Elec. Heat, MCO M 2-Pipe Heat and Cool w/ Aux. Elec. Heat, ACO N 2-Pipe Cool w/ Total Elec. Heat, MCO P 2-Pipe Cool w/ Total Elec. Heat, ACO Q 4-Pipe Heat and Cool, MCO R 4-Pipe Heat and Cool, ACO Thermostat A Basic Electronic Wall Series,, Vertical, ACO B Basic Electronic Wall Series,, Horizontal, ACO C Basic Series, 6, Unit Mounted, ACO P Basic 24V igital, 7-ay Programmable, ACO N Basic 24V igital, Non-Programmable, ACO F Premium 24V igital, 7-ay Programmable/ BACnet with Proportional Fan/Valves Option, ACO G Premium 24V igital BACnet with Proportional Fan/Valves Option, ACO

14 AI Certification IEC s Modular Hi-Rise Series units are certified in compliance with Air-Conditioning, Heating, and Refrigeration Institute (AI) industry standard AI-440 for room fan coil units. Approved standard ratings are tabulated below. PSC Motor Standard Ratings Model Size Coil Rows MAY, MBY, MMY, MSY MPY, MAY, MBY, MMY, MSY MPY MY Air Flow Rating (SCFM) Water Pressure rop (ft. water) Total Cap. (Btuh) Sensible Cap. (Btuh) Power Input (Watts) ,00 7, ,200 7, ,600 9, ,600 9, ,900 4, ,000, ,00 7, ,400 9, , ,700 24, , ,200 2, , ,00 28, , ,00 0, , ,000, ,00 7, ,200 7, ,600 9, ,600 9, ,900 4, ,000, ,00 7, ,400 9, , ,700 24, , ,200 2, , ,00 28, , ,00 29, ,00 7, ,200 7, ,600 9, ,600 9, ,900 4, ,000, ,00 7, ,400 9, , ,700 24, , ,200 2, ,400 24, , ,00 0, , ,000, EC Motor Standard Ratings Model Size Coil Rows MAY, MBY, MMY, MSY MPY, MAY, MBY, MMY, MSY MPY MY Air Flow Rating (SCFM) Water Pressure rop (ft. water) Total Cap. (Btuh) Sensible Cap. (Btuh) Power Input (Watts) ,00 7, ,200 7, ,600 9, ,600 9, ,900 4, ,000, ,00 7, ,400 9, , ,700 24, , ,200 2, , ,00 28, , ,00 0, , ,000, ,00 7, ,200 7, ,600 9, ,600 9, ,900 4, ,400, ,00 7, ,400 9,00 7 0, ,700 24, , ,200 2, , ,00 28, , ,00 0, ,700 7, ,200 7, ,400 8, ,600 9, ,900 4, ,900 4, ,00 7, ,400 9, , ,700 24, , ,000 2, , ,700 28, , ,00 0, ,0.0 48,000, NOTES:. Ratings are based on 80 F B and 67 F WB EAT, 4 F EWT, 0 F water temperature rise, high fan speed, motor voltage --60, and airflow under dry coil conditions. 2. Ratings shown for itto, Siamese itto and Primary/Secon dary configurations are for each unit in the two-unit system.. For all application ratings, use IEC s computer selection program, the quick-selection ratings provided in this catalog, or contact your local IEC representative. 4. For additional information, please consult AI s website at 4

15 C-ETL-US Listing IEC s Modular Hi-Rise Series units are listed by ETL. The C-ETL-US listing signifies that IEC s fan coil units have been examined by ETL and are in compliance with both the U.S. and Canadian applicable standards. Hydronic Heating Base Capacity Rows -Row 2-Row -Row 4-Row EWT 60 F 60 F 40 F 40 F Unit Coil Size GPM NOTES:. All base hot water capacities are given in thousands of BTUH (MBH). 2. Ratings are based on nominal CFM at 70 F EAT and 60 F EWT.. For information regarding performance at specific conditions, please use the IEC rating program or consult your IEC representative for assistance.

16 0. Unit Size 0 - MPY, MMY, MSY, MAY, MBY ESP (in.w.c.) High Med Low SCFM PSC Motor Fan Curve: -Row 4-Row ECM Operating Range: NOTE: ply air grille and return air panel static pressure losses are included in all fan performance curves for all sizes. 0. Unit Size 04 - MPY, MMY, MSY, MAY, MBY ESP (in.w.c.) High Med Low SCFM PSC Motor Fan Curve: -Row 4-Row ECM Operating Range: 6

17 0. Unit Size 06 - MPY, MMY, MSY, MAY, MBY ESP (in.w.c.) Low Med High SCFM PSC Motor Fan Curve: -Row 4-Row ECM Operating Range: Unit Size 08 - MPY, MMY, MSY, MAY, MBY 0.4 ESP (in.w.c.) Low Med High SCFM PSC Motor Fan Curve: -Row 4-Row ECM Operating Range: 7

18 Unit Size 0 - MPY, MMY, MSY, MAY, MBY ESP (in.w.c.) Low Med High SCFM PSC Motor Fan Curve: -Row 4-Row ECM Operating Range: Unit Size 2 - MPY, MMY, MSY, MAY, MBY ESP (in.w.c.) Low Med High SCFM PSC Motor Fan Curve: -Row 4-Row ECM Operating Range: 8

19 Thermal Overload Protection All PSC motors furnished by IEC contain internal thermal overload protection. The overload automatically resets when the temperature returns to a safe limit. Underwriters Laboratories Inc. approves the motor and thermal overload combination at locked rotor conditions only. PSC Motor Performance ata MPY, MAY/MBY, MMY/MSY, MY Voltage 60 Hz -Phase Hz -Phase Hz -Phase Hz -Phase Fan Speed High Medium Low High Medium Low High Medium Low High Medium Low NOTE: Total unit motor Amps and Watts are shown. Unit Size Nominal HP /0 /20 / / / /4 Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts

20 MPY (AI 260) Sound Power ata UNIT SIZE RATING CASING RAIATE w/# Style RA Panel & Alum. Grille UCTE ISCHARGE w/# Style RA Panel & Alum. Grille CASING RAIATE w/# Style RA Panel & Alum. Grille UCTE ISCHARGE w/# Style RA Panel & Alum. Grille CASING RAIATE w/# Style RA Panel & Alum. Grille UCTE ISCHARGE w/# Style RA Panel & Alum. Grille CASING RAIATE w/# Style RA Panel & Alum. Grille UCTE ISCHARGE w/# Style RA Panel & Alum. Grille CASING RAIATE w/# Style RA Panel & Alum. Grille UCTE ISCHARGE w/# Style RA Panel & Alum. Grille CASING RAIATE w/# Style RA Panel & Alum. Grille UCTE ISCHARGE w/# Style RA Panel & Alum. Grille SOUN POWER LEVEL, Lw (db reference one picowatt) CFM 2 Hz 20 Hz 00 Hz K Hz 2K Hz 4K Hz 8K Hz H FAN SPEE M L H M L H M L H M L H M L H M L H M L H M L H M L H M L H M L H M L NOTES:. Unit Test Configuration: Front urn / Front ply, 4 Row, 4 FPI Coil, High Speed, VAC PSC Motor, # urn Air Panel, Aluminum Grille, /2 dual density fiberglass insulation. 2. Casing Radiated Testing per AI : Casing radiated with free inlet, Sound Rating of ucted Air Moving and Conditioning Equipment.. ucted ischarge Testing per AI : ucted discharge, Sound Rating of ucted Air Moving and Conditioning Equipment. 4. Sound power data is expressed in decibels, db RE: x 0-2 w (picowatts). A-wgt (dba) 20

21 MPY (AI 0) Sound Power ata UNIT SIZE RATING CASING RAIATE w/# Style RA Panel & Alum. Grille CASING RAIATE w/# Style RA Panel & Alum. Grille CASING RAIATE w/# Style RA Panel & Alum. Grille CASING RAIATE w/# Style RA Panel & Alum. Grille CASING RAIATE w/# Style RA Panel & Alum. Grille CASING RAIATE w/# Style RA Panel & Alum. Grille SOUN POWER LEVEL, Lw (db reference one picowatt) CFM 2 Hz 20 Hz 00 Hz K Hz 2K Hz 4K Hz 8K Hz H FAN SPEE M L H M L H M L H M L H M L H M L A-wgt (dba) NOTES:. Unit Test Configuration: Front urn / Front ply, 4 Row, 4 FPI Coil, 0.0 High Speed, VAC PSC Motor, # urn Air Panel, Aluminum Grille, /2 dual density fiberglass insulation. 2. Casing Radiated Testing per AI 0-200: Casing radiated with free inlet, Sound Rating of ucted Air Moving and Conditioning Equipment.. Sound power data is expressed in decibels, db RE: x 0-2 w (picowatts). 2

22 MY Sound Power ata UNIT SIZE RATING CASING RAIATE w/# Style RA Panel & Alum. Grille FAN SPEE CFM SOUN POWER LEVEL, Lw (db reference one picowatt) 2 Hz 20 Hz 00 Hz K Hz 2K Hz 4K Hz 8K Hz H M L A-wgt (dba) CASING RAIATE w/# Style RA Panel & Alum. Grille CASING RAIATE w/# Style RA Panel & Alum. Grille CASING RAIATE w/# Style RA Panel & Alum. Grille CASING RAIATE w/# Style RA Panel & Alum. Grille CASING RAIATE w/# Style RA Panel & Alum. Grille H M L H M L H M L H M L H M L NOTES:. Unit Test Configuration: Front urn / Front ply, 4 Row, 4 FPI Coil, VAC PSC Motor, # urn Air Panel, Aluminum Grille, /2 dual density fiberglass insulation. 2. Casing Radiated Testing per AI 0-200: Casing radiated with free inlet, Sound Rating of ucted Air Moving and Conditioning Equipment.. Sound power data is expressed in decibels, db RE: x 0-2 w (picowatts). 22

23 Electric heaters are available on IEC Modular Hi-Rise Series fan coil units for the following applications. Total Electric Heat Total electric heat eliminates the requirement for a boiler. Heating and/or cooling may be available on an individual basis throughout the year. Two-pipe chilled water is used for cooling, and the electric heater is used for heating. Individual room controls can be supplied for either manual or automatic changeover. Auxiliary Electric Heat Auxiliary electric heat is ideal for tempering room air between seasons and during the cooling season when chilled water is being circulated. Individual room controls are supplied to provide electric heat only when chilled water is being circulated. uring regular heating season, heating is provided by hot water being circulated in the system. Construction Heater coils of high-grade resistance wire are supported by ceramic insulators on plated steel brackets. These heating elements are located at the discharge area of the motor/ blower. High limit thermal cutouts protect the unit in the event of airflow loss. There are many special applications and control sequences for electric heat. For special applications please consult the factory. Electric Heater Selection Voltage 20V 208V 240V 277V kw Unit Size

24 MPY Modular Hi-Rise Concealed -/8 (92) C L MPY 4-PIPE OPTION -/8 (92) SUPPLY AIR OPENING(S) UCT COLLAR, /2"() ETENSION (TYPICAL) CONTROL OPENING (SURFACE MOUNT STAT) ACOUSTICAL SERVICE ACCESS PANEL RISER, SUPPLY & RETURN ( COPPER) RISER, RAIN, ( COPPER ) R C L S I E -/4 (2) ELECTRICAL KNOCKOUTS H C H ACCESS PANEL (CONTROL BO) MOTOR, SPEE, PSC, W/QUICK CONNECT RAIN PAN 6 (600) 4 (72) (27) (2) G CONTROL BO MOLE CONNECTOR FOR FIEL INSTALLE STAT B KNOCKOUT (FOR OPTIONAL REMOTE MOUNT- ING)/SIE BLOWER AIR VENT, MANUAL RETURN AIR OPENING FILTER, TOWAWAY, "(2), (F&I) COIL /2"() O.. COPPER TUBE FLEIBLE RAIN TUBE/P-TRAP A E SUPPLY & RETURN TOP UCT COLLAR, " (2) " EPANE SECTION OF RISER /2"() ISOLATION BALL VALVES (F&I) 88 (22) RISER LENGTH TAIL PIECE (NOTE G) Unit Model imension Inches (Millimeters) Single ply ouble ply Top ply E G H I A B A B C Unit Weight* MPY 0 4 (6) 8 (20) 4 (6) 6 (2) 4 (6) 0 (24) 7 (42) -/2 (8) -/2 (8) 4 (6) 80 (82) MPY 04 4 (6) 2 (0) 4 (6) 6 (2) 4 (6) 0 (24) 7 (42) -/2 (8) -/2 (8) 4 (6) 22 (02) MPY 06 8 (47) 0 (24) 8 (47) 6 (2) 6 (406) 2 (0) 20 (08) (2) 2 () 8 (47) 240 (09) MPY 08 8 (47) 2 (0) 8 (47) 6 (2) 6 (406) 2 (0) 20 (08) (2) 2 () 8 (47) 260 (8) MPY 0 22 (9) 8 (20) 8 (47) 6 (406) 24 (60) (2) 22 (9) 280 (27) MPY 2 22 (9) 8 (20) 8 (47) 6 (406) 24 (60) (2) 22 (9) 0 (8) NOTES: * Unit weights are approximate (shown in pounds and kg) and are based on dry coils, minimum rows and exclude packaging, valves or other components.. Units are fabricated of galvanized steel with a 6 gauge galvanized fan deck. rawing is provided for reference only. 2. All risers are insulated with /2" () closed cell insulation. imensions may vary with options ordered.. Thermostats shipped loose for field connection. Consult IEC website for submittal drawings. 4. Risers are factory piped to coil with valves as specified.. Blower, motor, valves, coil and filter are accessible through the return air opening. 6. Unit and control box are insulated with /2" () coated glass-fiber insulation. 7. Riser length = {floor to floor +2" ()}. Maximum riser length is " (292). Consult project submittal for riser specifications. 8. Maximum riser size is 2-/2" (64) diameter. If larger sizes are required, please consult the factory. 9. Expansion loops in hot water heating circuits as required. 0. A 9"x2-/4" (229x7) slot is provided in the inside back panel for coil connection penetration to permit expansion and contraction of risers. Care must be taken to position the risers so that coil connection is at center of slot.. This drawing is pictorial. (See unit arrangements for actual supply and return air orientation.) 2. imensions are in inches, dimensions in ( ) are in millimeters. 24

25 MPY Modular Hi-Rise Concealed with Electric Heat -/8 (92) LC MPY 4-PIPE OPTION -/8 (92) SUPPLY AIR OPENING(S) R C L S ELECTRICAL KNOCKOUTS H C H -/4 (2) (2) G A SUPPLY & RETURN TOP UCT COLLAR, " (2) " EPANE SECTION OF RISER UCT COLLAR, /2"() ETENSION (TYPICAL) CONTROL OPENING (SURFACE MOUNT STAT) ACOUSTICAL SERVICE ACCESS PANEL ACCESS PANEL (CONTROL BO) MOTOR, SPEE, PSC, W/ QUICK CONNECT RAIN PAN CONTROL BO MOLE CONNECTOR FOR FIEL INSTALLE STAT KNOCKOUT (FOR OPTIONAL REMOTE MOUNTING) /SIE BLOWER AIR VENT, MANUAL RETURN AIR OPENING FILTER, TOWAWAY, "(2), (F&I) COIL /2"() O.. COPPER TUBE B 6 (600) 4 (72) 88 (22) RISER LENGTH STRIP HEATER (OPTIONAL) HEATER LIMIT SWITCH, (F&I) (OPTIONAL) /2"() ISOLATION BALL VALVES (F&I) (NOTE G) RISER, SUPPLY & RETURN (COPPER) RISER, RAIN, (COPPER) I E FLEIBLE RAIN TUBE/P-TRAP (27) E TAIL PIECE Unit Model imension Inches (Millimeters) Single ply ouble ply Top ply E F G H I A B A B C Unit Weight* MPY 0 4 (6) 8 (20) 4 (6) 6 (2) 4 (6) 0 (24) 7 (42) 22-/8 (68) -/2 (8) -/2 (8) 4 (6) 80 (82) MPY 04 4 (6) 2 (0) 4 (6) 6 (2) 4 (6) 0 (24) 7 (42) 22-/8 (68) -/2 (8) -/2 (8) 4 (6) 22 (02) MPY 06 8 (47) 0 (24) 8 (47) 6 (2) 6 (406) 2 (0) 20 (08) 2-/8 (64) (2) 2 () 8 (47) 240 (09) MPY 08 8 (47) 2 (0) 8 (47) 6 (2) 6 (406) 2 (0) 20 (08) 2-/8 (64) (2) 2 () 8 (47) 260 (8) MPY 0 22 (9) 8 (20) 8 (47) 6 (406) 24 (60) 29-/8 (746) (2) 22 (9) 280 (27) MPY 2 22 (9) 8 (20) 8 (47) 6 (406) 24 (60) 29-/8 (746) (2) 22 (9) 0 (8) NOTES: * Unit weights are approximate (shown in pounds and kg) and are based on dry coils, minimum rows and exclude packaging, valves or other components.. Units are fabricated of galvanized steel with a 6 gauge galvanized fan deck. rawing is provided for reference only. 2. All risers are insulated with /2" () closed cell insulation. imensions may vary with options ordered.. Thermostats shipped loose for field connection. Consult IEC website for submittal drawings. 4. Risers are factory piped to coil with valves as specified.. Blower, motor, valves, coil and filter are accessible through the return air opening. 6. Unit and control box are insulated with /2" () coated glass-fiber insulation. 7. Riser length = {floor to floor +2" ()}. Maximum riser length is " (292). Consult project submittal for riser specifications. 8. Maximum riser size is 2-/2" (64) diameter. If larger sizes are required, please consult the factory. 9. Expansion loops in hot water heating circuits as required. 0. A 9"x2-/4" (229x7) slot is provided in the inside back panel for coil connection penetration to permit expansion and contraction of risers. Care must be taken to position the risers so that coil connection is at center of slot.. This drawing is pictorial. (See unit arrangements for actual supply and return air orientation.) 2. imensions are in inches, dimensions in ( ) are in millimeters. 2

26 MPY Modular Hi-Rise Concealed with Chase -/8 (92) C L MPY 4-PIPE OPTION -/8 (92) RISER CHASE SUPPLY AIR OPENING(S) UCT COLLAR, /2"() ETENSION (TYPICAL) CONTROL OPENING (SURFACE MOUNT STAT) ACOUSTICAL BY-PASS PANEL RISER, SUPPLY & RETURN (COPPER) RISER, RAIN, (COPPER) C L R S I E -/4 (2) ELECTRICAL KNOCKOUTS H C H ACCESS PANEL (CONTROL BO) MOTOR, SPEE, PSC, W/ QUICK CONNECT RAIN PAN SUPPLY & RETURN TOP UCT COLLAR, " (2) G A (2) CONTROL BO MOLE CONNECTOR FOR FIEL INSTALLE STAT KNOCKOUT (FOR OPTIONAL REMOTE MOUNTING) BLOWER AIR VENT, MANUAL RETURN AIR 4 OPENING (72) 6 FILTER, (600) TOWAWAY, "(2), (F&I) COIL /2"() O.. COPPER TUBE FLEIBLE RAIN TUBE/P-TRAP B (27) E F " EPANE SECTION OF RISER 88 (22) (NOTE 7) TAIL PIECE RISER LENGTH /2"() ISOLATION BALL VALVES (F&I) Unit Model imension Inches (Millimeters) Single ply ouble ply Top ply E F G H I A B A B C Unit Weight* MPY 0 4 (6) 8 (20) 4 (6) 6 (2) 4 (6) 0 (24) 7 (42) 22-/8 (68) -/2 (8) -/2 (8) 4 (6) 80 (82) MPY 04 4 (6) 2 (0) 4 (6) 6 (2) 4 (6) 0 (24) 7 (42) 22-/8 (68) -/2 (8) -/2 (8) 4 (6) 22 (02) MPY 06 8 (47) 0 (24) 8 (47) 6 (2) 6 (406) 2 (0) 20 (08) 2-/8 (64) (2) 2 () 8 (47) 240 (09) MPY 08 8 (47) 2 (0) 8 (47) 6 (2) 6 (406) 2 (0) 20 (08) 2-/8 (64) (2) 2 () 8 (47) 260 (8) MPY 0 22 (9) 8 (20) 8 (47) 6 (406) 24 (60) 29-/8 (746) (2) 22 (9) 280 (27) MPY 2 22 (9) 8 (20) 8 (47) 6 (406) 24 (60) 29-/8 (746) (2) 22 (9) 0 (8) NOTES: * Unit weights are approximate (shown in pounds and kg) and are based on dry coils, minimum rows and exclude packaging, valves or other components.. Units are fabricated of galvanized steel with a 6 gauge galvanized fan deck. rawing is provided for reference only. 2. All risers are insulated with /2" () closed cell insulation. imensions may vary with options ordered.. Thermostats shipped loose for field connection. Consult IEC website for submittal drawings. 4. Risers are factory piped to coil with valves as specified.. Blower, motor, valves, coil and filter are accessible through the return air opening. 6. Unit and control box are insulated with /2" () coated glass-fiber insulation. 7. Riser length = {floor to floor +2" ()}. Maximum riser length is " (292). Consult project submittal for riser specifications. 8. Maximum riser size is 2-/2" (64) diameter. If larger sizes are required, please consult the factory. 9. Expansion loops in hot water heating circuits as required. 0. A 9"x2-/4" (229x7) slot is provided in the inside back panel for coil connection penetration to permit expansion and contraction of risers. Care must be taken to position the risers so that coil connection is at center of slot.. This drawing is pictorial. (See unit arrangements for actual supply and return air orientation.) 2. imensions are in inches, dimensions in ( ) are in millimeters. 26

27 MPY Modular Hi-Rise Concealed with Chase with Electric Heat Unit Model -/8 (92) MPY 4-PIPE OPTION RISER CHASE, OPTIONAL -/8 (92) SUPPLY AIR OPENING(S) UCT COLLAR, /2"() ETENSION (TYPICAL) CONTROL OPENING (SURFACE MOUNT STAT) BLOWER ACOUSTICAL SERVICE ACCESS PANEL RISER, SUPPLY & RETURN ( COPPER) RISER, RAIN, ( COPPER ) CL R S I E H C H -/4 (2) ELECTRICAL KNOCKOUTS ACCESS PANEL (CONTROL BO) MOTOR, SPEE,PSC, W/QUICK CONNECT RAIN PAN CONTROL BO MOLE CONNECTOR FOR FIEL INSTALLE STAT KNOCKOUT (FOR OPTIONAL REMOTE MOUNTING) AIR VENT, MANUAL RETURN AIR OPENING FILTER, TOWAWAY, "(2), (F&I) COIL /2"() O.. COPPER TUBE (2) G B 4 (72) 6 (600) (27) FLEIBLE RAIN TUBE/P-TRAP SUPPLY & RETURN TOP UCT COLLAR, " (2) " EPANE SECTION OF RISER A E F 88 (22) TAIL PIECE (NOTE 7) RISER LENGTH HEATER LIMIT SWITCH, (F&I) (OPTIONAL) STRIP HEATER (OPTIONAL) /2"() ISOLATION BALL VALVES (F&I) imension Inches (Millimeters) Single ply ouble ply Top ply E F G H I A B A B C Unit Weight* MPY 0 4 (6) 8 (20) 4 (6) 6 (2) 4 (6) 0 (24) 7 (42) 22-/8 (68) -/2 (8) -/2 (8) 4 (6) 80 (82) MPY 04 4 (6) 2 (0) 4 (6) 6 (2) 4 (6) 0 (24) 7 (42) 22-/8 (68) -/2 (8) -/2 (8) 4 (6) 22 (02) MPY 06 8 (47) 0 (24) 8 (47) 6 (2) 6 (406) 2 (0) 20 (08) 2-/8 (64) (2) 2 () 8 (47) 240 (09) MPY 08 8 (47) 2 (0) 8 (47) 6 (2) 6 (406) 2 (0) 20 (08) 2-/8 (64) (2) 2 () 8 (47) 260 (8) MPY 0 22 (9) 8 (20) 8 (47) 6 (406) 24 (60) 29-/8 (746) (2) 22 (9) 280 (27) MPY 2 22 (9) 8 (20) 8 (47) 6 (406) 24 (60) 29-/8 (746) (2) 22 (9) 0 (8) NOTES: * Unit weights are approximate (shown in pounds and kg) and are based on dry coils, minimum rows and exclude packaging, valves or other components.. Units are fabricated of galvanized steel with a 6 gauge galvanized fan deck. rawing is provided for reference only. 2. All risers are insulated with /2" () closed cell insulation. imensions may vary with options ordered.. Thermostats shipped loose for field connection. Consult IEC website for submittal drawings. 4. Risers are factory piped to coil with valves as specified.. Blower, motor, valves, coil and filter are accessible through the return air opening. 6. Unit and control box are insulated with /2" () coated glass-fiber insulation. 7. Riser length = {floor to floor +2" ()}. Maximum riser length is " (292). Consult project submittal for riser specifications. 8. Maximum riser size is 2-/2" (64) diameter. If larger sizes are required, please consult the factory. 9. Expansion loops in hot water heating circuits as required. 0. A 9"x2-/4" (229x7) slot is provided in the inside back panel for coil connection penetration to permit expansion and contraction of risers. Care must be taken to position the risers so that coil connection is at center of slot.. This drawing is pictorial. (See unit arrangements for actual supply and return air orientation.) 2. imensions are in inches, dimensions in ( ) are in millimeters. 27

28 MAY/MBY itto (Chase Concealed) SUPPLY AIR OPENING(S) MAY 4-PIPE OPTION -/8 (92) LC -/8 (92) (2) H H G C MAY A R S -/4 (2) MBY GYPSUM BOAR, /8"(6) TYPE "" " EPANE SECTION OF RISER ELECTRICAL KNOCKOUTS SUPPLY & RETURN TOP UCT COLLAR, "(2) UCT COLLAR, /2"() ETENSION (TYPICAL) CONTROL OPENING (SURFACE MOUNTE STAT) ACOUSTICAL SERVICE ACCESS PANEL ACCESS PANEL (CONTROL BO) MOTOR, SPEE, PSC, W/QUICK CONNECT RAIN PAN CONTROL BO MOLE CONNECTOR FOR FIEL INSTALLE STAT KNOCKOUT (FOR OPTIONAL REMOTE MOUNTING)/SIE BLOWER AIR VENT, MANUAL RETURN AIR OPENING FILTER, TOWAWAY, "(2), (F&I) COIL /2"() O.. COPPER TUBE 6 (600) B 4 (72) 88 (22) (NOTE G) RISER LENGTH /2"() ISOLATION BALL VALVES (F&I) RISER, SUPPLY & RETURN (COPPER) RISER, RAIN, (COPPER) I E (27) FLEIBLE RAIN TUBE/P-TRAP E THERMAFIBER INSULATION J TAIL PIECE Unit Model Single ply ouble ply Top ply A B A B C imension Inches (Millimeters) E G H I J Unit Weight* MAY/MBY 0 4 (6) 8 (20) 4 (6) 6 (2) 4 (6) 0 (24) 7 (42) -/2 (8) -/2 (8) 4 (6) 9-/8 (007) 60 (6) MAY/MBY 04 4 (6) 2 (0) 4 (6) 6 (2) 4 (6) 0 (24) 7 (42) -/2 (8) -/2 (8) 4 (6) 9-/8 (007) 40 (204) MAY/MBY 06 8 (47) 0 (24) 8 (47) 6 (2) 6 (406) 2 (0) 20 (08) (2) 2 () 8 (47) 4-/8 (9) 480 (27) MAY/MBY 08 8 (47) 2 (0) 8 (47) 6 (2) 6 (406) 2 (0) 20 (08) (2) 2 () 8 (47) 4-/8 (9) 20 (26) MAY/MBY 0 22 (9) 8 (20) 8 (47) 6 (406) 24 (60) (2) 22 (9) -/8 (62) 60 (24) MAY/MBY 2 22 (9) 8 (20) 8 (47) 6 (406) 24 (60) (2) 22 (9) -/8 (62) 60 (276) NOTES: * Unit weights are approximate (shown in pounds and kg) and are based on dry coils, minimum rows and exclude packaging, valves or other components.. Units are fabricated of galvanized steel with a 6 gauge galvanized fan deck. 2. All risers are insulated with /2" () closed cell insulation.. Thermostats shipped loose for field connection. 4. Risers are factory piped to coil with valves as specified.. Blower, motor, valves, coil and filter are accessible through the return air opening. 6. Unit and control box are insulated with /2" () coated glass-fiber insulation. 7. Riser length = {floor to floor +2" ()}. Maximum riser length is " (292). Consult project submittal for riser specifications. 8. Maximum riser size is 2-/2" (64) diameter. If larger sizes are required, please consult the factory. 9. Expansion loops in hot water heating circuits as required. 0. A 9"x2-/4" (229x7) slot is provided in the inside back panel for coil connection penetration to permit expansion and contraction of risers. Care must be taken to position the risers so that coil connection is at center of slot.. This drawing is pictorial. (See unit arrangements for actual supply and return air orientation.) 2. imensions are in inches, dimensions in ( ) are in millimeters. 28

29 MAY/MBY itto (Chase Concealed) with Electric Heat LC SUPPLY AIR OPENING(S) UCT COLLAR, /2"() ETENSION (TYPICAL) CONTROL OPENING (SURFACE MOUNTE STAT) ACOUSTICAL SERVICE ACCESS PANEL RISER, SUPPLY & RETURN ( COPPER) RISER, RAIN, ( COPPER ) MAY 4-PIPE OPTION I E -/8 (92) -/8 (92) ACCESS PANEL (CONTROL BO) MOTOR, SPEE, PSC, W/ QUICK CONNECT RAIN PAN CONTROL BO MOLE CONNECTOR FOR FIEL INSTALLE STAT KNOCKOUT (FOR OPTIONAL REMOTE MOUNTING)/SIE BLOWER AIR VENT, MANUAL RETURN AIR OPENING FILTER, TOWAWAY, "(2), (F&I) COIL /2"() O.. COPPER TUBE FLEIBLE RAIN TUBE/P-TRAP (2) 6 (600) H H G 4 (72) B (27) C MAY A E R S -/4 (2) J MBY ELECTRICAL KNOCKOUTS GYPSUM BOAR, /8"(6) TYPE "" SUPPLY & RETURN TOP UCT COLLAR, "(2) " EPANE SECTION OF RISER THERMAFIBER INSULATION 88 (22) (NOTE 7) TAIL PIECE RISER LENGTH STRIP HEATER, (F&I) (OPTIONAL) HEATER LIMIT SWITCH, (F&I) (OPTIONAL) /2"() ISOLATION BALL VALVES (F&I) Unit Model Single ply ouble ply Top ply A B A B C imension Inches (Millimeters) E G H I J Unit Weight* MAY/MBY 0 4 (6) 8 (20) 4 (6) 6 (2) 4 (6) 0 (24) 7 (42) -/2 (8) -/2 (8) 4 (6) 9-/8 (007) 60 (6) MAY/MBY 04 4 (6) 2 (0) 4 (6) 6 (2) 4 (6) 0 (24) 7 (42) -/2 (8) -/2 (8) 4 (6) 9-/8 (007) 40 (204) MAY/MBY 06 8 (47) 0 (24) 8 (47) 6 (2) 6 (406) 2 (0) 20 (08) (2) 2 () 8 (47) 4-/8 (9) 480 (27) MAY/MBY 08 8 (47) 2 (0) 8 (47) 6 (2) 6 (406) 2 (0) 20 (08) (2) 2 () 8 (47) 4-/8 (9) 20 (26) MAY/MBY 0 22 (9) 8 (20) 8 (47) 6 (406) 24 (60) (2) 22 (9) -/8 (62) 60 (24) MAY/MBY 2 22 (9) 8 (20) 8 (47) 6 (406) 24 (60) (2) 22 (9) -/8 (62) 60 (276) NOTES: * Unit weights are approximate (shown in pounds and kg) and are based on dry coils, minimum rows and exclude packaging, valves or other components.. Units are fabricated of galvanized steel with a 6 gauge galvanized fan deck. 2. All risers are insulated with /2" () closed cell insulation.. Thermostats shipped loose for field connection. 4. Risers are factory piped to coil with valves as specified.. Blower, motor, valves, coil and filter are accessible through the return air opening. 6. Unit and control box are insulated with /2" () coated glass-fiber insulation. 7. Riser length = {floor to floor +2" ()}. Maximum riser length is " (292). Consult project submittal for riser specifications. 8. Maximum riser size is 2-/2" (64) diameter. If larger sizes are required, please consult the factory. 9. Expansion loops in hot water heating circuits as required. rawing is provided for reference only. imensions may vary with options ordered. Consult IEC website for submittal drawings. 0. A 9"x2-/4" (229x7) slot is provided in the inside back panel for coil connection penetration to permit expansion and contraction of risers. Care must be taken to position the risers so that coil connection is at center of slot.. This drawing is pictorial. (See unit arrangements for actual supply and return air orientation.) 2. imensions are in inches, dimensions in ( ) are in millimeters. 29

30 MMY Modular Hi-Rise Concealed Primary -/8 (92) C L MMY 4-PIPE OPTION -/8 (92) C L R S H C H SUPPLY AIR OPENING(S) UCT COLLAR, /2"() ETENSION (TYPICAL) CONTROL OPENING (SURFACE MOUNT STAT) ACOUSTICAL BY-PASS PANEL RISER, SUPPLY & RETURN (COPPER) RISER, RAIN, (COPPER) I E -/4 (2) ELECTRICAL KNOCKOUTS ACCESS PANEL (CONTROL BO) MOTOR, SPEE, PSC, W/ QUICK CONNECT RAIN PAN CONTROL BO MOLE CONNECTOR FOR FIEL INSTALLE STAT KNOCKOUT (FOR OPTIONAL REMOTE MOUNTING) BLOWER AIR VENT, MANUAL RETURN AIR OPENING FILTER, TOWAWAY, "(2), (F&I) COIL /2"() O.. COPPER TUBE FLEIBLE RAIN TUBE/P-TRAP 6 (600) 4 (72) (27) G (2) B E A SUPPLY & RETURN TOP UCT COLLAR, " (2) 9 (99) (27) " EPANE SECTION OF RISER 88 (22) TAIL PIECE (NOTE 7) RISER LENGTH /2"() ISOLATION BALL VALVES (F&I) imension Inches (Millimeters) Unit Unit Single ply ouble ply Top ply Model Weight* A B A B C E G H I MMY 0 4 (6) 8 (20) 4 (6) 6 (2) 4 (6) 0 (24) 7 (42) -/2 (8) -/2 (8) 4 (6) 80 (82) MMY 04 4 (6) 2 (0) 4 (6) 6 (2) 4 (6) 0 (24) 7 (42) -/2 (8) -/2 (8) 4 (6) 22 (02) MMY 06 8 (47) 0 (24) 8 (47) 6 (2) 6 (406) 2 (0) 20 (08) (2) 2 () 8 (47) 240 (09) MMY 08 8 (47) 2 (0) 8 (47) 6 (2) 6 (406) 2 (0) 20 (08) (2) 2 () 8 (47) 260 (8) MMY 0 22 (9) 8 (20) 8 (47) 6 (406) 24 (60) (2) 22 (9) 280 (27) MMY 2 22 (9) 8 (20) 8 (47) 6 (406) 24 (60) (2) 22 (9) 0 (8) NOTES: * Unit weights are approximate (shown in pounds and kg) and are based on dry coils, minimum rows and exclude packaging, valves or other components.. Units are fabricated of galvanized steel with a 6 gauge galvanized fan deck. 2. All risers are insulated with /2" () closed cell insulation.. Thermostats shipped loose for field connection. 4. Risers are factory piped to coil with valves as specified.. Blower, motor, valves, coil and filter are accessible through the return air opening. 6. Unit and control box are insulated with /2" () coated glass-fiber insulation. 7. Riser length = {floor to floor +2" ()}. Maximum riser length is " (292). Consult project submittal for riser specifications. 8. Maximum riser size is 2-/2" (64) diameter. If larger sizes are required, please consult the factory. 9. Expansion loops in hot water heating circuits as required. rawing is provided for reference only. imensions may vary with options ordered. Consult IEC website for submittal drawings. 0. A 9"x2-/4" (229x7) slot is provided in the inside back panel for coil connection penetration to permit expansion and contraction of risers. Care must be taken to position the risers so that coil connection is at center of slot.. This drawing is pictorial. (See unit arrangements for actual supply and return air orientation.) 2. imensions are in inches, dimensions in ( ) are in millimeters. 0

31 MMY Modular Hi-Rise Concealed Primary with Electric Heat -/8 (92) C L MMY 4-PIPE OPTION BLOWER -/8 (92) SUPPLY AIR OPENING(S) UCT COLLAR, /2"() ETENSION (TYPICAL) CONTROL OPENING (SURFACE MOUNT STAT) ACOUSTICAL SERVICE ACCESS PANEL RISER, SUPPLY & RETURN ( COPPER) RISER, RAIN, ( COPPER ) C L R S I E -/4 (2) ELECTRICAL KNOCKOUTS H C H ACCESS PANEL (CONTROL BO) MOTOR, SPEE, PSC, W/ QUICK CONNECT RAIN PAN CONTROL BO MOLE CONNECTOR FOR FIEL INSTALLE STAT KNOCKOUT (FOR OPTIONAL REMOTE MOUNTING)/SIE (2) AIR VENT, MANUAL 6 (600) RETURN AIR OPENING FILTER, TOWAWAY, "(2), (F&I) COIL /2"() O.. COPPER TUBE FLEIBLE RAIN TUBE/P-TRAP B G 4 (72) (27) A E SUPPLY & RETURN TOP UCT COLLAR, " (2) " EPANE SECTION OF RISER 9 (99) (27) 88 (22) RISER LENGTH TAIL PIECE (NOTE 7) HEATER LIMIT SWITCH, (F&I) (OPTIONAL) STRIP HEATER (OPTIONAL) /2"() ISOLATION BALL VALVES (F&I) imension Inches (Millimeters) Unit Unit Single ply ouble ply Top ply Model Weight* A B A B C E G H I MMY 0 4 (6) 8 (20) 4 (6) 6 (2) 4 (6) 0 (24) 7 (42) -/2 (8) -/2 (8) 4 (6) 80 (82) MMY 04 4 (6) 2 (0) 4 (6) 6 (2) 4 (6) 0 (24) 7 (42) -/2 (8) -/2 (8) 4 (6) 22 (02) MMY 06 8 (47) 0 (24) 8 (47) 6 (2) 6 (406) 2 (0) 20 (08) (2) 2 () 8 (47) 240 (09) MMY 08 8 (47) 2 (0) 8 (47) 6 (2) 6 (406) 2 (0) 20 (08) (2) 2 () 8 (47) 260 (8) MMY 0 22 (9) 8 (20) 8 (47) 6 (406) 24 (60) (2) 22 (9) 280 (27) MMY 2 22 (9) 8 (20) 8 (47) 6 (406) 24 (60) (2) 22 (9) 0 (8) NOTES: * Unit weights are approximate (shown in pounds and kg) and are based on dry coils, minimum rows and exclude packaging, valves or other components.. Units are fabricated of galvanized steel with a 6 gauge galvanized fan deck. 2. All risers are insulated with /2" () closed cell insulation.. Thermostats shipped loose for field connection. 4. Risers are factory piped to coil with valves as specified.. Blower, motor, valves, coil and filter are accessible through the return air opening. 6. Unit and control box are insulated with /2" () coated glass-fiber insulation. 7. Riser length = {floor to floor +2" ()}. Maximum riser length is " (292). Consult project submittal for riser specifications. 8. Maximum riser size is 2-/2" (64) diameter. If larger sizes are required, please consult the factory. 9. Expansion loops in hot water heating circuits as required. rawing is provided for reference only. imensions may vary with options ordered. Consult IEC website for submittal drawings. 0. A 9"x2-/4" (229x7) slot is provided in the inside back panel for coil connection penetration to permit expansion and contraction of risers. Care must be taken to position the risers so that coil connection is at center of slot.. This drawing is pictorial. (See unit arrangements for actual supply and return air orientation.) 2. imensions are in inches, dimensions in ( ) are in millimeters.

32 MSY Modular Hi-Rise Concealed Secondary -/8 (92) LC MSY 4-PIPE OPTION -/8 (92) H SUPPLY AIR OPENING(S) UCT COLLAR, /2"(2) ETENSION CONTROL OPENING (SURFACE MOUNT STAT) ACOUSTICAL BY-PASS PANEL CL S R C E I H -/4 (2) ELECTRICAL KNOCKOUTS ACCESS PANEL (CONTROL BO) MOTOR, SPEE, PSC, W/QUICK CONNECT RAIN PAN CONTROL BO MOLE CONNECTOR FOR FIEL INSTALLE STAT KNOCKOUT (FOR OPTIONAL REMOTE MOUNTING) BLOWER AIR VENT, MANUAL RETURN AIR OPENING FILTER, TOWAWAY, "(2), (F&I) (2) G B 4 (72) 6 (600) COIL /2"() O.. COPPER TUBE FLEIBLE RAIN TUBE/P-TRAP (27) A E (27) 88 (22) 9 (99) SUPPLY AN RETURN TOP UCT COLLAR, "(2) /2"() ISOLATION BALL VALVES (F&I) SHIPPING BRACE imension Inches (Millimeters) Unit Unit Single ply ouble ply Top ply Model Weight* A B A B C E G H I MSY 0 4 (6) 8 (20) 4 (6) 6 (2) 4 (6) 0 (24) 7 (42) -/2 (8) -/2 (8) 4 (6) 62 (7) MSY 04 4 (6) 2 (0) 4 (6) 6 (2) 4 (6) 0 (24) 7 (42) -/2 (8) -/2 (8) 4 (6) 20 (92) MSY 06 8 (47) 0 (24) 8 (47) 6 (2) 6 (406) 2 (0) 20 (08) (2) 2 () 8 (47) 26 (98) MSY 08 8 (47) 2 (0) 8 (47) 6 (2) 6 (406) 2 (0) 20 (08) (2) 2 () 8 (47) 24 (06) MSY 0 22 (9) 8 (20) 8 (47) 6 (406) 24 (60) (2) 22 (9) 22 (4) MSY 2 22 (9) 8 (20) 8 (47) 6 (406) 24 (60) (2) 22 (9) 27 (2) NOTES: * Unit weights are approximate (shown in pounds and kg) and are based on dry coils, minimum rows and exclude packaging, valves or other components.. Units are fabricated of galvanized steel with a 6 gauge galvanized fan deck. 2. Thermostats shipped loose for field connection.. Coil with valves as specified. 4. Blower, motor, valves, coil and filter are accessible through the return air opening.. Unit and control box are insulated with /2" () coated glass-fiber insulation. 6. Expansion loops in hot water heating circuits as required. rawing is provided for reference only. imensions may vary with options ordered. Consult IEC website for submittal drawings. 7. A 9"x2-/4" (229x7) slot is provided in the inside back panel for coil connection penetration to permit expansion and contraction of risers. Care must be taken to position the risers so that coil connection is at center of slot. 8. This drawing is pictorial. (See unit arrangements for actual supply and return air orientation.) 9. imensions are in inches, dimensions in ( ) are in millimeters. 2

33 MSY Modular Hi-Rise Concealed Secondary with Electric Heat LC -/8 (92) MSY 4-PIPE OPTION -/8 (92) H SUPPLY AIR OPENING(S) UCT COLLAR, /2"() ETENSION CONTROL OPENING (SURFACE MOUNT STAT) BLOWER ACOUSTICAL SERVICE ACCESS PANEL CL S R C I E H -/4 (2) ELECTRICAL KNOCKOUTS ACCESS PANEL (CONTROL BO) MOTOR, SPEE, PSC, W/QUICK CONNECT RAIN PAN CONTROL BO MOLE CONNECTOR FOR FIEL INSTALLE STAT KNOCKOUT (FOR OPTIONAL REMOTE MOUNTING)/SIE AIR VENT, MANUAL 6 (600) RETURN AIR OPENING FILTER, TOWAWAY, "(2), (F&I) COIL /2"() O.. COPPER TUBE FLEIBLE RAIN TUBE/P-TRAP 4 (72) (27) (2) G B A E (27) 88 (22) 9 (99) SUPPLY AN RETURN TOP UCT COLLAR, "(2) HEATER LIMIT SWITCH, (F&I) (OPTIONAL) STRIP HEATER (OPTIONAL) /2"() ISOLATION BALL VALVES (F&I) SHIPPING BRACE imension Inches (Millimeters) Unit Unit Single ply ouble ply Top ply Model Weight* A B A B C E G H I MSY 0 4 (6) 8 (20) 4 (6) 6 (2) 4 (6) 0 (24) 7 (42) -/2 (8) -/2 (8) 4 (6) 62 (7) MSY 04 4 (6) 2 (0) 4 (6) 6 (2) 4 (6) 0 (24) 7 (42) -/2 (8) -/2 (8) 4 (6) 20 (92) MSY 06 8 (47) 0 (24) 8 (47) 6 (2) 6 (406) 2 (0) 20 (08) (2) 2 () 8 (47) 26 (98) MSY 08 8 (47) 2 (0) 8 (47) 6 (2) 6 (406) 2 (0) 20 (08) (2) 2 () 8 (47) 24 (06) MSY 0 22 (9) 8 (20) 8 (47) 6 (406) 24 (60) (2) 22 (9) 22 (4) MSY 2 22 (9) 8 (20) 8 (47) 6 (406) 24 (60) (2) 22 (9) 27 (2) NOTES: * Unit weights are approximate (shown in pounds and kg) and are based on dry coils, minimum rows and exclude packaging, valves or other components.. Units are fabricated of galvanized steel with a 6 gauge galvanized fan deck. 2. Thermostats shipped loose for field connection.. Coil with valves as specified. 4. Blower, motor, valves, coil and filter are accessible through the return air opening.. Unit and control box are insulated with /2" () coated glass-fiber insulation. 6. Expansion loops in hot water heating circuits as required. rawing is provided for reference only. imensions may vary with options ordered. Consult IEC website for submittal drawings. 7. A 9"x2-/4" (229x7) slot is provided in the inside back panel for coil connection penetration to permit expansion and contraction of risers. Care must be taken to position the risers so that coil connection is at center of slot. 8. This drawing is pictorial. (See unit arrangements for actual supply and return air orientation.) 9. imensions are in inches, dimensions in ( ) are in millimeters.

34 MY Modular Hi-Rise Cabinet CL -/8 (92) -/8 (92) MY 4-PIPE OPTION.. STEEL CORE GRILLE ASSY CL R S ELECTRICAL KNOCKOUTS (27) B E A " EPANSION SECTION OF RISER HINGE CONTROL ACCESS OOR T'STAT BLOWER CABINET CAMLOCKS SPEE SWITCH ELECTRICAL ACCESS PANEL MOTOR, SPEE, PSC SERIES 'L' RETURN AIR PANEL CONTROL BO /2"() ISOLATION BALL VALVES (F&I) AIR VENT, MANUAL 88 (22) (NOTE G) F RISER, SUPPLY & RETURN, (TYPE "M" COPPER) RISER, RAIN, (TYPE "M" COPPER) G C FILTER, T.A, "(2), (F&I) COIL /2"() O.. TUBE RAIN PAN FLEIBLE RAIN TUBE/P-TRAP WG. IS PICTORAL SEE UNIT ARRGMTS. FOR ACTUAL C TAIL PIECE RISER LENGTH Unit Model imension Inches (Millimeters) Unit Single ply ouble ply C E F G Weight* A B A B MY 0 4 (6) 8 (20) 4 (6) 6 (2) 7 (42) 22-/8 (68) 2-/2 (64) 22-/8(68) 4-/4 (7) 202 (92) MY 04 4 (6) 2 (0) 4 (6) 8 (20) 7 (42) 22-/8 (68) 2-/2 (64) 22-/8(68) 4-/4 (7) 247 (2) MY 06 4 (6) 2 (0) 4 (6) 8 (20) 20 (08) 2-/8 (64) 2-/2 (64) 26-/8(676) 7-/4 (4) 262 (9) MY 08 4 (6) 6 (406) 4 (6) 0 (24) 20 (08) 2-/8 (64) 2-/2 (64) 26-/8(676) 7-/4 (4) 286 (0) MY 0 8 (47) 6 (406) 4 (6) 2 (0) 24 (60) 29-/8 (747) 2-/2 (64) -/8(79) 7-/4 (4) (4) MY 2 8 (47) 6 (406) 4 (6) 2 (0) 24 (60) 29-/8 (747) 2-/2 (64) -/8(79) 7-/4 (4) 6 (2) NOTES: * Unit weights are approximate (shown in pounds and kg) and are based on dry coils, minimum rows and exclude packaging, valves or other components.. Units are fabricated of galvanized steel with a 6 gauge galvanized fan deck. 2. All risers are insulated with /2 () closed cell insulation. rawing is provided for reference only.. Thermostats shipped loose for field connection. imensions may vary with options ordered. 4. Risers are factory piped to coil with valves as specified. Consult IEC website for submittal drawings.. Blower, motor, valves, coil and filter are accessible through the return air opening. 6. Unit and control box are insulated with /2" () coated glass-fiber insulation. 7. Riser length = {floor to floor +2" ()}. Maximum riser length is " (292). Consult project submittal for riser specifications. 8. Maximum riser size is 2-/2" (64) diameter. If larger sizes are required, please consult the factory. 9. Expansion loops in hot water heating circuits as required. 0. A 9"x2-/4" (229x7) slot is provided in the inside back panel for coil connection penetration to permit expansion and contraction of risers. Care must be taken to position the risers so that coil connection is at center of slot.. This drawing is pictorial. (See unit arrangements for actual supply and return air orientation.) 2. imensions are in inches, dimensions in ( ) are in millimeters. 4

35 MY Modular Hi-Rise Cabinet with Electric Heat -/8 (92) CL MY 4-PIPE OPTION -/8 (92) R S.. STEEL CORE GRILLE ASSY HINGE CONTROL ACCESS OOR T'STAT BLOWER F RISER, SUPPLY & RETURN, (TYPE "M" COPPER) RISER, RAIN, (TYPE "M" COPPER) CL G C ELECTRICAL KNOCKOUTS CABINET CAMLOCKS ELECTRICAL ACCESS PANEL MOTOR, SPEE, PSC SERIES 'L' RETURN AIR PANEL (27) B CONTROL BO /2"() ISOLATION BALL VALVES (F&I) AIR VENT, MANUAL FILTER, T.A, "(2), (F&I) COIL /2"() O.. TUBE RAIN PAN FLEIBLE RAIN TUBE/P-TRAP WG. IS PICTORAL SEE UNIT ARRGMTS. FOR ACTUAL E A C " EPANSION SECTION OF RISER 88 (22) TAIL PIECE (NOTE 7) RISER LENGTH STRIP HE (OPTION HEATER SWITCH, (OPTION Unit Model imension Inches (Millimeters) Unit Single ply ouble ply C E F G Weight* A B A B MY 0 4 (6) 8 (20) 4 (6) 6 (2) 7 (42) 22-/8 (68) 2-/2 (64) 22-/8(68) 4-/4 (7) 202 (92) MY 04 4 (6) 2 (0) 4 (6) 8 (20) 7 (42) 22-/8 (68) 2-/2 (64) 22-/8(68) 4-/4 (7) 247 (2) MY 06 4 (6) 2 (0) 4 (6) 8 (20) 20 (08) 2-/8 (64) 2-/2 (64) 26-/8(676) 7-/4 (4) 262 (9) MY 08 4 (6) 6 (406) 4 (6) 0 (24) 20 (08) 2-/8 (64) 2-/2 (64) 26-/8(676) 7-/4 (4) 286 (0) MY 0 8 (47) 6 (406) 4 (6) 2 (0) 24 (60) 29-/8 (747) 2-/2 (64) -/8(79) 7-/4 (4) (4) MY 2 8 (47) 6 (406) 4 (6) 2 (0) 24 (60) 29-/8 (747) 2-/2 (64) -/8(79) 7-/4 (4) 6 (2) NOTES: * Unit weights are approximate (shown in pounds and kg) and are based on dry coils, minimum rows and exclude packaging, valves or other components.. Units are fabricated of galvanized steel with a 6 gauge galvanized fan deck. 2. All risers are insulated with /2 () closed cell insulation. rawing is provided for reference only.. Thermostats shipped loose for field connection. imensions may vary with options ordered. 4. Risers are factory piped to coil with valves as specified. Consult IEC website for submittal drawings.. Blower, motor, valves, coil and filter are accessible through the return air opening. 6. Unit and control box are insulated with /2" () coated glass-fiber insulation. 7. Riser length = {floor to floor +2" ()}. Maximum riser length is " (292). Consult project submittal for riser specifications. 8. Maximum riser size is 2-/2" (64) diameter. If larger sizes are required, please consult the factory. 9. Expansion loops in hot water heating circuits as required. 0. A 9"x2-/4" (229x7) slot is provided in the inside back panel for coil connection penetration to permit expansion and contraction of risers. Care must be taken to position the risers so that coil connection is at center of slot.. This drawing is pictorial. (See unit arrangements for actual supply and return air orientation.) 2. imensions are in inches, dimensions in ( ) are in millimeters.

36 Features and Options Standard Factory Installed Option Field Installed Option Air Flow Arrangement See Unit Configuration Coils -Rows 2-Pipe (MPY, MY, MMY/MSY, MAY/MBY) 4-Rows 2-Pipe (MPY, MY, MMY/MSY, MAY/MBY) /, /2, or 4/-Rows CW/HW (MPY, MY, MMY/MSY, MAY/MBY) Manual Air Vent Automatic Air Vent rain Pan Galvanized Internally Coated with a 2 part closed cell foam Stainless Steel Externally Coated with a 2 part closed cell foam Fin Material Aluminum w/galvanized End Sheets Copper w/stainless End Sheets & Bottom Coil Baffle Nickrome Wire Strip Electric Heater Filters " Throwaway non-woven synthetic " Permanent (washable media or aluminum mesh) " MERV 8 Pleated Insulation /2" Standard Fiberglass /2" Premium IAQ Fiberglass, sealed edges /2" Foil Face, taped edges /4" Closed Cell Hour Fire Rated Riser Chase (MAY/MBY) Motor Type Standard -Speed PSC Motors w/quick connect Plug Hi Static -Speed PSC Motors w/quick-connect Plug Motor Voltage 20//60 -Speed 208/20/277//60 -Speed ply Grilles Integral ouble eflection Aluminum ply Grille (MY) ouble eflection, Aluminum ply Grille ouble eflection, Aluminum ply Grille w/opposed Blade ampers Custom ply Grille urn Air Panel Louvered Front Panel (MY) (M) Standard Height with or without Frame (All except MY) (F) (F, H) Extended Height with or without Frame (All except MY) (G, J) Extended Height with or without Control oor (All except MY) (K, L) Custom urn Air Panel Cabinet Modifications Standard Height is 88", 79" Optional (88") (79") Custom Options Custom Colors Factory Special Quote 6

37 Features and Options Standard Factory Installed Option Field Installed Option Factory Special Quote Risers Riser Factory Installed Risers Shipped Loose Flex Hoses Riser Length (to ") (>") Riser iameter (/4" to 2-/2") (>2-/2") Closed Cell Riser Insulation /2" /4" Fiberglass Riser Insulation /2" " Riser/rain Material Type M Copper Type L Copper Riser Extension (M or L) Controls Service Switch with Lockout Tabs Single Point Power Connection Incoming Power Fusing 24V Controls Condensate Float Switch Thermostats Surface Mounted w/tile Ring Unit Mounted Wall/Remote Mounted Special Control (C) Outside Air ampers Manual Controlled amper Motorized Controlled amper 7

38 As detailed in the table below, we offer a control for most of our customer s needs. Additional controls and devices are available to meet even the most demanding operating logic. -speed Fan Control All of our basic control schemes utilize a -speed switch to modulate the cooling output, to maximize the percentage of latent heat removal, and to further minimize the sound level when maximum cooling or heating performance is not required. Low Voltage Control (24V) An optional low voltage control is available with all of our control schemes. Thermostats Condensate Float Switch This optional switch shuts down the unit when the water level in the drain pan reaches an unsafe level. Building code changes in much of our country may require this type of device. Service Switches We offer optional service switches for use by maintenance and service personnel. Fusing We offer optional incoming power fusing as well as blower motor and control sub-fusing for units that use electric heat. System Compatibility Thermostat Type* A B C P N F G 2-Pipe, Heat Only 2-Pipe, Cool Only 2-Pipe, Heat/Cool 2-Pipe, Heat/Cool with Auxilary Electric Heat 2-Pipe, Cool with Total Electric Heat 4-Pipe, Heat & Cool Features 24VAC Programmable Non-Programmable Surface Mount Remote/Wall Mount -Speed Fan Proportional Fan (0-0VC) Continuous Fan Opt Opt Opt Opt Cycling Fan Opt Opt Opt Opt Opt Opt Remote Temp Sensor Opt Opt Adjustable Operating Range (Range Stop Kit) Kit Kit Kit SFR SFR SFR SFR igital isplay & Buttons Local Temp. Set-Back Water Temp. Purge Cycle Changeover Pipe Sensor Aqua Stat Proportional Control Valves Floating Control Valves (2P Only) *Legend: A Basic Electronic Wall Series,, Vertical, ACO B Basic Electronic Wall Series,, Horizontal, ACO C Basic Series, 6, Unit Mounted, ACO P Basic 24V igital, 7-ay Programmable, ACO N Basic 24V igital, Non-Programmable, ACO F Premium 24V igital, 7-ay Programmable/BACnet with Proportional Fan/Valves Option, ACO G Premium 24V igital BACnet with Proportional Fan/Valves Option, ACO 8

39 urn Air Panels F H G J K L H W W W W W W NOTE: See table on next page for height and width information. 9

40 Panel Type F G H J K L U V Unit Size and imensions 0/04 06/08 0/2 H W H W H W (40) (94) (40) (49) (40) (97) (2) (94) (2) (49) (2) (97) (89) (84) (89) (48) (89) (87) (4) (84) (4) (48) (4) (87) (2) (94) (2) (49) (2) (97) (4) (84) (4) (48) (4) (87) (2248) (4) (2248) (60) (2248) (7) 68. (740) 2.0 (4) 68. (740) 24.0 (60) 68. (740) 28.0 (7) NOTE: imensions shown in inches and millimeters {inches(mm)}. General Specifications: Heavy gauge galvanized steel with arctic white powdercoat finish Rear of panel is insulated with /2" dual density fiberglass Integral stamped steel return air grille /4 turn tamper-proof fasteners for panel removal Removal of panel provides service access to all internal components Framed panel series requires separate field installation of frame urn Air/Access Panel Application Control Mounting Options. Surface mounted controls: This requires a a tile ring mounted above the return air panel and quick-connect plug wiring on the thermostat. After the drywall/sheetrock has been applied to the cabinet, the thermostat plug will be attached to a matching plug in the unit and the thermostat will be fastened to the tile ring. (Not available for MY models) 2. Unit mounted: Thermostat is mounted behind the control door or the return air panel.. Remote wall mounted: Thermostat is mounted on a wall remote from the cabinet and wiring from the unit to thermostat is done in the field. 4. Other Considerations: All above (#, 2, & ) are for drywall attached directly to the cabinet. (Not available for MY models). Panel F, H, R, S G, J, K, L F, H, K, L, R, S F, H, J, L, R, S 40

41 Classic Aluminum urn Air/Access Grille ply Air Grilles H Type R: Anodized Aluminum Type S: Arctic White NOTE: Classic style supply air grille shown. W Unit Size and imensions¹ 0/04 06/08 0/2 W.2 (86) 9.2 (488) 2.2 (89) H. (40). (40). (40) NOTE: imensions shown in inches and millimeters {inches(mm)}. General Specifications: Fully louvered core grille is mounted in a full frame. Core grille is removable without tools and provides access to all internal components. Frame is clear anodized extruded aluminum. Grille louvers are also clear anodized extruded aluminum. esigned for use with surface mounted or remote wall mounted controls. Use with dry wall directly applied to cabinet or with space between dry wall and cabinet. 4 Unit Size Nominal CFM Recommended Grille Sizes Single ply* ouble ply 4 (6) x 8 (20) 4 (6) x 2 (0) 8 (47) x 0 (24) 8 (47) x 2 (0) 22 (9) x 6 (406) 22 (9) x 6 (406) 4 (6) x 6 (2) 4 (6) x 6 (2) 8 (47) x 6 (2) 8 (47) x 6 (2) 22 (9) x 8 (20) 22 (9) x 8 (20) Top ply 4 (6) x 0 (24) 4 (6) x 0 (24) 6 (406) x 2 (0) 6 (406) x 2 (0) 8 (47) x 6 (406) 8 (47) x 6 (406) NOTE: Single-side supply units are available with indicated supply openings on 88" tall cabinets only. Consult the factory for cabinets less than 88". Specifications: Frame and blades are 606 extruded aluminum alloy with 200- R satin anodized finish. The frame has a typical wall thickness of.00" and is separated from the blades with injection-molded nylon bushings. This method of assembly minimizes corrosion and vibration. The frame mounting holes are dimpled, allowing for a counter-sunk fastener head appearance. All blades are airfoil in design, individually adjustable and spaced /4" on center. At the outer edge of the frame is a Continued on next page.

42 specially engineered channel which retains an extruded flexible vinyl bulb gasket that produces a positive air seal at the mounting surface, minimizing smudging. An optional opposed blade damper is screwdriveroperated through the face of the unit and has the same extruded aluminum construction and injection-molded nylon bushings. The unit achieves an effective area of 80% with the blades set at a 0 pattern, thus eliminating high velocity and pressure drop at the grille face. Wider deflection with reduced throw may be achieved at the 22 and 4 blade settings with slightly increased sound levels. Suitable for sidewall application. Available in clear anodized, white or a variety of custom colors. Contact the factory for available optional colors and color chart. Filters Unit Size Nominal " Filter Size MPY, MAY/MBY, MMY/MSY, MY 0 2-/2 (6) x 24-/4 (66) 04 2-/2 (6) x 24-/4 (66) 06 6-/4 (4) x 26-/4 (679) 08 6-/4 (4) x 26-/4 (679) 0 20-/2 (2) x 29-/4 (74) 2 20-/2 (2) x 29-/4 (74) NOTE: Sizes shown are nominal ordering sizes. 42

43 4 Modular Hi-Rise Series

44 Contact your local IEC Sales Representative for further details and pricing applicable to this product. Visit our website (iec-okc.com) to find your local IEC Sales Rep. IEC Catalog Part #: I CA-00 Revision (4/208) International Environmental Corporation PO Box 298 Oklahoma City, OK P: F:

BUILD YOUR REPUTATION ON OURS. Universal Modular Hi-Rise Series FAN COIL TECHNICAL CATALOG

BUILD YOUR REPUTATION ON OURS. Universal Modular Hi-Rise Series FAN COIL TECHNICAL CATALOG BUILD YOUR REPUTATION ON OURS Universal Modular Hi-Rise Series FAN COIL TECHNICAL CATALOG TABLE OF CONTENTS 2 Table of Contents 3 Universal Modular Hi-Rise Family 4 Features and benefits 5 Product Application

More information

Vertical V*B Series Fan Coil Technical Catalog

Vertical V*B Series Fan Coil Technical Catalog Vertical V*B Series Fan Coil Technical Catalog Vertical Hideaway (VCB) 200 CFM to 1200 CFM The Vertical Hideaway (VCB) fan coil unit is designed for concealed applications. The coil section is lined with

More information

FCC Fan-Coil Units High-Performance, Vertical

FCC Fan-Coil Units High-Performance, Vertical FCC Fan-Coil s High-Performance, Vertical Model FCC construction features Piping and supply-duct connections are from top of unit, eliminating the need for side or back access Right or left-hand configurations

More information

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH MHCCW-10-05 Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled Water Fan Coil with Electric Heat 2-Pipe Nominal Size:

More information

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH MHCCW-06-00 Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.21 HVAC Guide Specifications Chilled or Hot Water Fan Coil 2-Pipe Nominal Size: 18,000 BTUH

More information

VERTICAL FAN COIL UNITS

VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS VERTICAL FAN COIL UNITS Model: CT & TCE 2 - Pipe 350 cfm to 1200 cfm capacity 4-row water coil 120v or 24v controls Electric heating coil (TCE Model) Fresh air connection from remote

More information

Product Specifications. Vertical Floor Consoles By First Co.

Product Specifications. Vertical Floor Consoles By First Co. NOW WITH 18 GAUGE CABINET AND FACTORY INSTALLED SERVICE SWITCH Product Specifications VFB Series VSB Series VCB Series Vertical Console Fan Coils 300-00 CFM Vertical Floor Consoles By First Co. VFB Series

More information

HiLine Vertical Stacking Fan Coils. Type FHSS and FHSK. Catalog

HiLine Vertical Stacking Fan Coils. Type FHSS and FHSK. Catalog HiLine Vertical Stacking Fan Coils Type FHSS and FHSK Catalog 770-17 Table of Contents Introduction.... 3 Daikin Applied HiLine Fan-Coil Units...3 Nomenclature...3 Introduction.... 4 Low CFM design (300

More information

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH MHNCCW-04-01 (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Fan Coil 4-Pipe Nominal Size: 12,000

More information

Energy Efficient Easy to Install Extended Service Life. Vertical Direct Drive Blower Coils

Energy Efficient Easy to Install Extended Service Life. Vertical Direct Drive Blower Coils Energy Efficient Easy to Install Extended Service Life Engineered to save our customers money Eliminate the belt and pulleys Energy efficient EC Motor Improve indoor air quality Nominal CFM range of 00

More information

engineering guide FH Fan-Coil Units Low-Profile, Horizontal

engineering guide FH Fan-Coil Units Low-Profile, Horizontal engineering guide FH Fan-Coil Units Low-Profile, Horizontal FORM 115.26-EG7 (908) Table of contents FH Fan-Coil Units Low-Profile, Horizontal Features and Benefits... Construction Features... Standard

More information

DIRECT DRIVE BLOWER COILS

DIRECT DRIVE BLOWER COILS DIRECT DRIVE BLOWER COILS Horizontal HDY Vertical VDY Upgrade to IEC s Direct Drive Blower Coils Energy Efficient Energy Efficient Easy Easy to Installation Install Extended Service Life Engineered to

More information

Catalog C: McQuay Horizontal Concealed Fan Coil Unit

Catalog C: McQuay Horizontal Concealed Fan Coil Unit Catalog C: 700-1 McQuay Horizontal Concealed Fan Coil Unit Model THC Sizes 200 Through 1200 CFM McQuay THC Horizontal Concealed Fan Coil Nomenclature F THC 1 H02 Fan-coil Type of Unit THC = Horizontal

More information

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System PART 1 SYSTEM DESCRIPTION 1.1 The HVAC system is based on the CGC HYBRID Hydronic Heat Pump System. 1.2 The system will automatically

More information

SeasonMaker ThinLine Fan-coil Units

SeasonMaker ThinLine Fan-coil Units Catalog C: 720-12 SeasonMaker ThinLine Fan-coil Units Type TSH & TSC Horizontal Design TSS, TPF, TSF & TSB Vertical Design C L I S T E D Ratings Certified by the Air Conditioning & Refrigeration Institute

More information

SeasonMaker ThinLine Fan-coil Units

SeasonMaker ThinLine Fan-coil Units Catalog C: 720-12 SeasonMaker ThinLine Fan-coil Units Type TSH & TSC Horizontal Design TSS, TPF, TSF & TSB Vertical Design C L I S T E D Ratings Certified by the Air Conditioning & Refrigeration Institute

More information

catalog CDV Fan-Coil Units High-Performance, Vertical

catalog CDV Fan-Coil Units High-Performance, Vertical catalog CDV Fan-Coil Units High-Performance, Vertical Catalog: ET115.26-EG8 (415) TABLE OF CONTENTS CDV Fan-Coil Units High-Performance, Vertical Features and Benefits... 3 Construction Features... 4 Standard

More information

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH 318 MHNCCX NOMENCLATURE BREAKDOWN 4-Pipe Heat/Cool Ceiling Concealed Fan Coil MHNCCW- XX - XX Ceiling Concealed

More information

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal

More information

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 4-Pipe Nominal

More information

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL PREPARED FOR: DATE: JOB NAME: WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL EQUIPMENT DETAILS ITEM TAG DESCRIPTION MODEL NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 EQUIPMENT

More information

Large Capacity Fan Coil Units Catalog Belt-Drive and Direct-Drive Cabinet and Hideaway Models

Large Capacity Fan Coil Units Catalog Belt-Drive and Direct-Drive Cabinet and Hideaway Models Large Capacity Fan Coil Units Catalog 735-12 Belt-Drive and Direct-Drive Cabinet and Hideaway Models Table of Contents Agency Listing and Nomenclature... 3 Overview....................................

More information

VariCool VAV Engineering Guide

VariCool VAV Engineering Guide Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control

More information

RAV Engineering Guide

RAV Engineering Guide VERTICAL HIGH-RISE FAN COIL UNITS RAV Engineering Guide SO TOUGH, WE GUARANTEE IT. RAVM RAVL RAVE RAVS RARM RARS RARP Table of Contents Features and Benefits... 3 Construction Features... 4 Standard and

More information

Horizontal and Vertical DIRECT DRIVE BLOWER COIL UNITS. Rating and selection at

Horizontal and Vertical DIRECT DRIVE BLOWER COIL UNITS. Rating and selection at Horizontal and Vertical DIRECT DRIVE BER COIL UNITS Rating and selection at www.enviro-tec.com CDH/CDV TABLE OF CONTENTS Construction Features...3 Fan Assembly...4 Optional Construction...5 Electric Heat...6

More information

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil MHCFC4W-16-01 Chilled/Hot Water Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 48,000 BTUH Rev. 1.1 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 48,000 BTUH Multiaqua

More information

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil MHCFC4W-04-01 Chilled/Hot Water Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 12,000 BTUH Rev. 1.2 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 12,000 BTUH Multiaqua

More information

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil MHCFC4W-08-01 Chilled/Hot Water Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 24,000 BTUH Rev. 1.1 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 24,000 BTUH Multiaqua

More information

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II, 3 Ton Series, gives you a SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall

More information

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units Advance Product Data 42WKN Hydronic Fan Coil Units 3 4 to 2 1 2 Tons UNIT SIZES 004-010 UNIT SIZES 016,020 The new Carrier Hydronic Cassette offers a modern solution for a wide variety of small and medium

More information

Modular Supply Make-Up Air Unit

Modular Supply Make-Up Air Unit Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features

More information

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil 4-Pipe Heat / Cool Fan Coil 18,000 BTUH Rev. 1.11 HVAC Guide Specifications Chilled and Hot Water Cassette Fan Coil 4-Pipe Nominal Size: 18,000

More information

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

CATALOG. SKYPAK Self-Contained Heating/Cooling Units CATALOG SKYPAK Self-Contained Heating/Cooling Units FORM SK145.00-EG6 (1211) TABLE OF CONTENTS SKYPAK Self-Contained Heating/Cooling Units Introduction...3 Product Overview...3 Nomenclature...4 SKYPAK

More information

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH 233 CWA2 NOMENCLATURE BREAKDOWN 2-Pipe Heat/Cool with Electric Heat Multiposition Fan Coil Nominal

More information

Large Capacity Fan Coil Units Belt and Direct Drive Cabinet and Hideaway

Large Capacity Fan Coil Units Belt and Direct Drive Cabinet and Hideaway Catalog C: 735-7 Large Capacity Fan Coil Units Belt and Direct Drive Cabinet and Hideaway Direct Drive CUL Listed McQuay Large Capacity Fan Coil Units Page 2 / Catalog 735 Direct drive hideaway unit The

More information

HiLine Vertical Stacking Fan Coil Units

HiLine Vertical Stacking Fan Coil Units Catalog C: 770-13 HiLine Vertical Stacking Fan Coil Units Type HSS & KZZ CUL Listed McQuay HiLine fan coil units McQuay HiLine fan coil air conditioning units are designed for use in multiple floor apartments,

More information

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for: Date: 05/21/2001 Time: 02:57:44 PM Job Name: EarthWise VAV Terminal Units Full Spec Location: AnyTown, Earth Prepared by: Phone Number: Prepared for: Guide Spec Summary Option List SINGLE & DUAL DUCT UNIT

More information

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS 48GS-1SB 48GS018-060 HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINT 1998 Carrier Corporation Syracuse,

More information

Modular Hi-Rise Series Fan Coils INSTALLATION, OPERATION, & MAINTENANCE MANUAL

Modular Hi-Rise Series Fan Coils INSTALLATION, OPERATION, & MAINTENANCE MANUAL Modular Hi-Rise Models: MPY, MXY, MAY/MBY Ditto, MMY/MSY, MUY, and MGY BUILD YOUR REPUTATION ON OURS International Environmental Corporation (IEC) works continually to improve its products. As a result,

More information

EHH SERIES DRAW THROUGH FAN COILS CFM

EHH SERIES DRAW THROUGH FAN COILS CFM EHH SERIES DRAW THROUGH FAN COILS 400-5000 CFM TABLE OF CONTENTS TABLE OF CONTENTS 2 INTRODUCTION 3 GUIDE SPECIFICATIONS 4 UNIT OVERVIEW 6 TECHNICAL DATA 8 DIMENSIONS 10 COMPUTER SELECTION 11 GEMCOOL PROFILE

More information

HiLine Vertical Stacking Fan-coil Units

HiLine Vertical Stacking Fan-coil Units Catalog C: 770-12 HiLine Vertical Stacking Fan-coil Units Type HSS & KZZ ARI 440 CUL Listed McQuay SeasonMaker HiLine fan-coil units The McQuay HiLine SeasonMaker fan-coil air conditioning units are designed

More information

Submittal. RBVR Vertical Concealed Floor Mount FCU RBVR

Submittal. RBVR Vertical Concealed Floor Mount FCU RBVR FCU RBVR 1.0 07 25 18 RBVR Vertical Concealed Floor Mount Unit Size 02 03 04 06 08 10 A 23 3/16 [589] 27 3/16 [691] 33 3/16 [843] 43 3/16 [1097] 45 3/16 [1148] 59 3/16 [1503] B 22 ¾ [578] 26 ¾ [679] 32

More information

Commercial Fan Coil and Air Handling Equipment

Commercial Fan Coil and Air Handling Equipment FAN COILS AND AIR HANDLERS Commercial Fan Coil and Air Handling Equipment Chilled Water - Hot Water - Electric Heat Direct Drive - Belt Drive - Vertical Console P.O. Box 1390 Easton, MD 21601 USA Tel.

More information

SECTION CONVECTION HEATING AND COOLING UNITS

SECTION CONVECTION HEATING AND COOLING UNITS PART 1 GENERAL 1.01 SECTION INCLUDES A. Baseboard radiation. B. Finned tube radiation. C. Convectors. D. Unit heaters. E. Cabinet unit heaters. F. Fan-coil units. G. Unit ventilators. H. Blower-coil units.

More information

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-131.001 Page 1 Copyright 2017 Unico Inc. TABLE OF CONTENTS APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL

More information

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design Fan motor (PSC or ECM). UL Listed 1 insulation conforms to UL Test 181 and NFPA 90A. Plenum air filter rack. (Filter Optional) Casing has

More information

Concealed Ducted Split Series R-407C MBH

Concealed Ducted Split Series R-407C MBH Concealed Ducted Split Series R-407C 4-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION NOMENCLATURE UNIT RATING SUMMARY

More information

PRODUCT CATALOG BLOWER COILS.

PRODUCT CATALOG BLOWER COILS. 2016 PRODUCT CATALOG BLOWER COILS www.superiorrex.com SBH / SBV Series Design Features DESIGNED FOR MAXIMUM FLEXIBILITY Both Horizontal and Vertical Belt Drive Blower Coils are designed to maximize flexibility

More information

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE NOW AVAILABLE WITH AUTOSPEED V CONTROL Product Specifications MB Series MBE Series W Series Vertical / Horizontal Direct Drive Hydronic Fan Coils 0 CFM NEW OPTION AVAILABLE: AUTOSPEED V CONTROL PACKAGE

More information

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection Series PIN New Construction or Renovation Application Flexible Quiet Comfort Damage Protection ADIRONDACK AIRE New Construction or Renovation The Adirondack-Aire PIN Series zerozone chassis provides environment

More information

SpaceKeeper Console (SKC)

SpaceKeeper Console (SKC) SpaceKeeper Console (SKC) With finished cabinet or custom enclosure SKC 008-015 ¾ - 1¼ tons 12 W x 25¼ H x 48 L CGC-09 SpaceKeeper Console R410A MODEL NO. SKC _ 008 010 012 015 Net Cooling Capacity - Rated

More information

engineering guide FN Fan-Coil Units High-Performance, Horizontal

engineering guide FN Fan-Coil Units High-Performance, Horizontal engineering guide FN Fan-Coil Units High-Performance, Horizontal Form 115.26-EG3 (909) TABLE OF CONTENTS High-Performance, Horizontal Fan-Coil Units Features and Benefits...3 Unit Arrangements...4 Construction

More information

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE NOW AVAILABLE WITH AUTOSPEED V CONTROL Product Specifications MB Series MBE Series W Series Vertical / Horizontal Direct Drive Hydronic Fan Coils 00 0 CFM NEW OPTION AVAILABLE: AUTOSPEED V CONTROL PACKAGE

More information

CUH-11 CABINET UNIT HEATERS

CUH-11 CABINET UNIT HEATERS CUH- CABINET UNIT HEATERS Steam and Hot Water CABINET UNIT HEATERS SELECTION AND "ROUGH IN" MADE EASY - ONLY THE LENGTHS VARY The Beacon-Morris Cabinet Unit Heater is the industry s most recent design.

More information

R Series Cooling Manual

R Series Cooling Manual Mini Duct Heating and Air Conditioning Indoor Air Quality Systems R Series Cooling Manual Includes: RPM-E-50 Cooling Module RPM-E-0 Cooling Module RPM-E-00 Cooling Module Manufactured By Energy Saving

More information

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986 ENGINEERING DATA CB18 SERIES UP-FLOW CBS18 SERIES HORIZONTAL 2 To 5 Ton (7 To 18 kw) Nominal Cooling Capacity 7200 To 102 400 Btuh (2.1 To 30.0 kw) Optional Electrical Heat ENGINEERING DATA COILS MATCHED

More information

NEW FAN COILS BLOWER COILS AIR HANDLERS NEW PRODUCT OFFERING.

NEW FAN COILS BLOWER COILS AIR HANDLERS NEW PRODUCT OFFERING. NEW FAN COILS BLOWER COILS AIR HANDLERS NEW PRODUCT OFFERING Continuing Excellence Since the 1980s, Superior Rex has manufactured/sold an extensive range of fan coils and air handlers in the global marketplace.

More information

PACKAGE AIR CONDITIONER

PACKAGE AIR CONDITIONER PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior

More information

VertiCool Space Saver 2 to 15 Tons Water-Cooled and Chilled Water Air-Cooled w/remote Condenser

VertiCool Space Saver 2 to 15 Tons Water-Cooled and Chilled Water Air-Cooled w/remote Condenser VertiCool Space Saver 2 to 15 Tons Water-Cooled and Chilled Water Air-Cooled w/remote Condenser Unique Solutions for All-Indoor HVAC Projects Water-Cooled Chilled Water Your Choice for Limited Space Applications

More information

CWA4 Chilled & Hot Water Fan Coil

CWA4 Chilled & Hot Water Fan Coil CWA4 Chilled & Hot Water Fan Coil 4-Pipe Heat & Cool Fan Coil 24,000-60,000 BTUH 259 CWA4 NOMENCLATURE BREAKDOWN 4-Pipe Heat & Cool Multiposition Fan Coil Nominal BTUH 24=24,000 36=36,000 48=48,000 60=60,000

More information

SKYPAK II Heating & Cooling Self Contained Packages

SKYPAK II Heating & Cooling Self Contained Packages SKYPAK II Heating & Cooling Self Contained Packages SKYPAK II gives you a complete airconditioning and heating system as an all-in-one package unit. Designed for conventional through-the-wall installation

More information

GUIDE SPECIFICATIONS AQUARIUS ii

GUIDE SPECIFICATIONS AQUARIUS ii Catalog (AP Technical Data Sheet) GUIDE SPECIFICATIONS AQUARIUS ii AP Series Two Stage R-410A GENERAL Units shall be performance certified to ISO standard 13256-1 for Water Loop Heat Pump, Ground Water

More information

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw) High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN

VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-019 TABLE OF CONTENTS DESIGN & SPECIFICATIONS...3 APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL DATA... 5 SPECIFICATIONS...

More information

Q-TEC QC-Series Chilled Water Air Conditioner

Q-TEC QC-Series Chilled Water Air Conditioner Cooling Capacities: 13,3 to 49,3 BTUH (Based on EWT, GPM & CFM) Q-TEC QC-Series Chilled Water Air Conditioner The Q-TEC Series self-contained packaged chilled water air conditioner is designed to be installed

More information

High Heat COP. High/Low Stage

High Heat COP. High/Low Stage SOUND REFRIGERANT ENVIRONMENTALLY PHN5 Product Specifications 15 SEER, 8.0 HSPF, PACKAGE HEAT PUMP, 2-5 TONS Single Phase, 208/230V, Hz. REFRIGERATION CIRCUIT R--410A refrigerant Copper tube/aluminum fin

More information

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units TECHNICAL SPECIFICATIONS R7DA Series 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units 5.4 ISMRE Commercial System 81% Steady State Efficiency Standard Features Fits Pre-Existing Curbs High-Efficiency Low

More information

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through tons, up to 7,800 BTUH Heating The SPXB-HW Series "Suite 0" is a compact, throughthe-wall single package vertical HVAC

More information

VH Series B ENVIRO-STAC Vertical Hi-Rise Fan Coil Unit with Enhanced Humidity Control

VH Series B ENVIRO-STAC Vertical Hi-Rise Fan Coil Unit with Enhanced Humidity Control VH Series B ENVIRO-STAC Vertical Hi-Rise Fan Unit with Enhanced Humidity Control Motorized Bypass Damper Temperature and Humidity Controller Reheat Control Elastomeric Foam Insulation High Efficiency,

More information

Manufacturer of HVAC Equipment Since ,000 sq. ft. on 16 acres. Colton, California USA

Manufacturer of HVAC Equipment Since ,000 sq. ft. on 16 acres. Colton, California USA Manufacturer of HVAC Equipment Since 1916 400,000 sq. ft. on 16 acres Colton, California USA Visual factory Vertically integrated manufacturing BELT-DRIVEN AIR HANDLERS 800 12,000 CFM Horizontal Vertical

More information

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects VariCool VAV (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water Unique Solutions for All-Indoor HVAC Projects Water Source Heat Pump Water-Cooled Chilled Water Modular

More information

Catalog ThinLine Horizontal Fan Coils. Type FCHC, FCHH and FCHR. Exposed Horizontal Cabinet. Recessed Horizontal Cabinet

Catalog ThinLine Horizontal Fan Coils. Type FCHC, FCHH and FCHR. Exposed Horizontal Cabinet. Recessed Horizontal Cabinet ThinLine Horizontal Fan Coils Type FCHC, FCHH and FCHR Catalog 724-5 Exposed Horizontal Cabinet Recessed Horizontal Cabinet Concealed Horizontal Model Table of Contents Nomenclature and Certification...

More information

LETTER OF TRANSMITTAL

LETTER OF TRANSMITTAL LETTER OF TRANSMITTAL FRANK A. ANZALONE Date: FAA Job No. 157 GENERAL CONTRACTOR Attention: Mr. Brent Guilbeau - Coleman Partners 1401 Derek Drive, Suite B Hammond, LA 70403 3377 North Boulevard Phone:

More information

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018 Alpha Aire Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery Engineering Guide Effective February 018 CONTENTS PRODUCT FEATURES.......................... OPTIONS.....................................

More information

SECTION FAN COIL UNITS

SECTION FAN COIL UNITS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ E3FB090/E1FB120/F3EH090 & 120 7-1/2 & 10 NOMINAL TONS (60 HZ) 7 & 9 NOMINAL TONS (50 HZ) (9.0-9.2 EER) 208/230/460 VOLT ONLY 208/230 VOLT ONLY DESCRIPTION YORK has

More information

E4EB-xxx-H Series Downflow, Upflow Electric Furnaces

E4EB-xxx-H Series Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS E4EB-xxx-H Series Downflow, Upflow Electric Furnaces The E4 Series furnace is designed for all sizes of manufactured and modular homes. These units incorporate reliability and

More information

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw) FALCON Rooftop Units ACPSE 50/60Hz Cooling : 36 to 1388 MBH (11 to 407 ) Heating : 40 to 1298 MBH (12 to 380 ) R Products that perform...by people who care NOMENCLATURE 6 AC P S E 435 P - HP G Q 6-60 Hz

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703 TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.

More information

JH Series Installation

JH Series Installation JH Series Installation Space Heating / Fresh Air Make-Up From the Manufacturers of Hi-Velocity Systems TM Includes: JH-15 JH-30 Module-JH-Series-Installation-Manual-010118 Installation JH fan coils by

More information

KIC Air Curtains. Technical Guide

KIC Air Curtains. Technical Guide TGKIC-3 KIC Air Curtains Technical Guide AIR PERFORMANCE AIR MOVEMENT AND CONTROL ASSOCIATION INTERNATIONAL, INC. King certifies that the air curtains shown herein are licensed to bear the AMCA seal. The

More information

C13-Series Engineering Guide

C13-Series Engineering Guide Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................

More information

INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER

INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER INSTALLATION & OPERATING INSTRUCTIONS AEM SERIES VARIABLE SPEED MULTI-POSITION ELECTRIC HEAT AIR HANDLER MODEL (INCLUDING HEATER MODEL #) SERIAL # INSTALLER INSTALLATION DATE These instructions should

More information

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat SG-MAH-08 April 2016 MX Series Indoor Modular Blowers Electric Heat, Hot Heat, or No Heat Specification Guide Contents...Pa Page Standard Features... 2 Physical Data... 2 Blower Performance... 3 Nomenclature...

More information

VertiCool Aurora Engineering Guide

VertiCool Aurora Engineering Guide Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8

More information

THE TRANQUILITY 16 COMPACT (TC) SERIES

THE TRANQUILITY 16 COMPACT (TC) SERIES The Tranquility 16 Compact (TC) Series raises the bar for water-source heat pump effi ciencies, features and application fl exibility. Not only does the Tranquility 16 Compact Series exceed ASHRAE 90.1

More information

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz) DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage

More information

Q-Tec TM QC-Series Chilled Water Air Conditioner

Q-Tec TM QC-Series Chilled Water Air Conditioner Q-Tec TM QC-Series Chilled Water Air Conditioner Cooling Capacities:, to, BTUH (Based on EWT, GPM and ) The Q-Tec Series self-contained packaged chilled water air conditioner is designed to be installed

More information

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS 48GS(N)018-060 STANDARD EFFICIENCY 48GX(N)024-060 HIGH-EFFICIENCY 48GS(N)-2SB SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION

More information

Catalog ThinLine Horizontal Fan Coils. Type FCHC, FCHH and FCHR. Exposed Horizontal Cabinet. Recessed Horizontal Cabinet

Catalog ThinLine Horizontal Fan Coils. Type FCHC, FCHH and FCHR. Exposed Horizontal Cabinet. Recessed Horizontal Cabinet ThinLine Horizontal Fan Coils Type FCHC, FCHH and FCHR Catalog 724-8 Exposed Horizontal Cabinet Recessed Horizontal Cabinet Concealed Horizontal Model Table of Contents Nomenclature and Certification...

More information

SECTION WATER-SOURCE UNITARY HEAT PUMPS

SECTION WATER-SOURCE UNITARY HEAT PUMPS SECTION 23 81 46 PART 1 - GENERAL 1.1 DESCRIPTION SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph

More information

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com Greensource Residential Water Source Heat Pumps i Series: SV Model Simply Smart The i Series SV Model is a cost-effective single stage water source heat pump that is designed for commercial retrofit and

More information

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D FAN COIL UNITS FF1DNA, FF1DNE Sizes 018, 024, 030 FF1D FEATURES The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are

More information

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT TECHNICAL GUIDE SPLIT-SYSTEM HEAT PUMPS EA090/FA090 DESCRIPTION YORK has combined the latest concepts in modern technology with time-proven quality standards to design a split-system heat pump to meet

More information

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Single Package Rooftop, High---Efficiency Heat Pump Units With Field---Installed Electric Heat Sizes 08 --- 14 with Puron R (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS

More information

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Indoor Single Package Vertical, Air-Cooled Heat Pump Unit RetroAire Model Number: Capacity Range: VPRH 9,000 to 36,000 Btuh (2.6 to 10.5 kw) Part 1 General 1.01 UNIT DESCRIPTION A. Indoor, single package

More information

Water-Cooled Self-Contained Units

Water-Cooled Self-Contained Units CATALOG FORM SK145.15-EG1 (1017) Water-Cooled Self-Contained Units C-Series, Vertical Nomenclature WATER-COOLED SELF-CONTAINED UNIT 1, 2 3 4, 5, 6 7 8 9 10 11 12 13 14 15 16 17 CS V 180 B 2 M 1 V A A A

More information