PURGE-AIR MODULAR AIR MOVER KIT OPERATION AND MAINTENANCE MANUAL

Size: px
Start display at page:

Download "PURGE-AIR MODULAR AIR MOVER KIT OPERATION AND MAINTENANCE MANUAL"

Transcription

1 PURGE-AIR MODULAR AIR MOVER KIT OPERATION AND MAINTENANCE MANUAL Part No: PRG434 Issue: 1 (21-Oct-15) DIDSBURY ENGINEERING COMPANY LIMITED, Lower Meadow Road, Brooke Park, Handforth, Wilmslow, Cheshire, SK9 3LP, England. Tel: +44 (0) Fax: +44 (0) sales@didsbury.com

2 CHANGE HISTORY Issue Date Change Description First issue. Page ii Issue 1

3 ABBREVIATIONS psi Pound per Square Inch QR Quick Response SCFM Standard Cubic Feet per Minute Issue 1 Page iii

4 Section CONTENTS Page 1 PRG434 kit of parts Operation Introduction General safety information Required air supply Static conductive air ducting Fuel tank wing adaptor assembly Compressed air hose Operating instructions medium air mover (PRG318) Operating Instructions large air mover (PRG317) Annual maintenance General Large and medium air movers (PRG317 and PRG318) Static conductive air ducting, couplings and y-adaptors (SAFD20/10-EX, SAFD20/CU, SAFD20/YC) Fuel tank wing adaptor assemblies (PRG265T1) Air hose (PRG272) Further information Figure Page Figure 1 PRG434 kit of parts... 1 Figure 2 Connecting 200mm antistatic ducts using the SAFD20/CU coupling... 6 Figure 3 200mm ducts connected with SAFD20/CU coupling... 7 Figure 4 200mm antistatic ducting strap release... 7 Figure 5 Single wing tank purging arrangement (medium air mover)... 9 Figure 6 Dual wing tank purging arrangement (medium air mover) Figure 7 Schematic of triple wing tank purging arrangement Figure 8 Wing tank and centre tank ventilation arrangement Figure 9 Single wing tank purging arrangement (large air mover) Figure 10 Ducting storage Table Page Table 1 PRG434 kit components... 2 Page iv Issue 1

5 1 PRG434 kit of parts Figure 1 PRG434 kit of parts Issue 1 Page 1

6 Kit part numbers: Purge-Air Modular Air Mover Kit - part number: PRG434 Table 1 PRG434 kit components Item no. Part no. Description Qty - PRG431 Ducting kit 1 1 PRG421 Flight case 1 2 PRG436 Air mover label 1 3 PRG440 Contents label 1 4 SAFD20/10-EX Antistatic ducting 200mm x 10m /3 No. 6 x ³ ₈ self-tapping screw 4 - PRG432 Air mover kit 1 6 PRG272 ¾ x 15m yellow air hose assembly 2 7 PRG317 Large air mover assembly 1 8 PRG318 Medium air mover assembly 1 9 PRG422 Flight case 1 10 PRG437 Air mover label 1 11 PRG439 Air mover schematic 1 12 PRG441 Contents label /3 No. 6 x ³ ₈ self-tapping screw 4 - PRG433 Coupling kit 1 14 PRG265T1 Wing adaptor assembly with clamps 3 15 PRG423 Flight case 1 16 PRG438 Air mover label 1 17 PRG442 Contents label 1 18 SAFD20/CU 200mm diameter duct coupling 3 19 SAFD20/YC 200mm to 200mm duct y-adaptor /3 No. 6 x ³ ₈ self-tapping screw 4 Page 2 Issue 1

7 2 Operation 2.1 Introduction Didsbury Engineering s modular air mover kit offers a complete resource to allow personnel to ventilate aircraft fuel tanks safely. The large and medium air mover units are versatile and lightweight, with no moving parts. They operate on compressed air and are suitable for ventilating spaces containing volatile or hazardous atmospheres. The medium air mover (PRG318) features both intake and discharge air duct adaptor ports, while the large air mover (PRG317) provides only an intake port. Both units allow for easy attachment of the supplied antistatic air ducting. 2.2 General safety information Follow the airline / aircraft manufacturer s fuel tank entry procedures at all times. Only competent, trained persons must operate the equipment contained within the Purge-Air modular air mover kit in accordance with its manufacturer s instructions. Regularly check and service all equipment in accordance with its manufacturer s instructions. Thoroughly check all equipment before use. Thoroughly clean all equipment after use and before storage. Replace all consumable items as soon as possible after use and before storage. React to all fuel spills in accordance with local regulations. Do not use the modular air mover kit during electrical storms. Portable air movers must be located outside the controlled safety zone created around the aircraft. During operation, always correctly connect the air mover s bonding terminal to electrical ground with a grounding cable. Only operate the large and medium air mover units with a suitable compressed air supply. Firmly position the air mover units on a flat horizontal surface prior to operation. Prevent personnel from standing within range of the discharge from the air mover outlets as fuel vapour, liquid fuel and debris may be contained in its exhaust flume. Issue 1 Page 3

8 2.3 Required air supply The large and medium air movers operate using compressed air sourced from either a workshop airline or a portable air compressor. Maximum air pressure: Large air mover flow: Medium air mover flow: 101 psi (7 bar) 153 SCFM 50 SCFM Safety notes: When a portable compressor is used, it must be located outside the controlled safety zone created around the aircraft and suitably grounded. 2.4 Static conductive air ducting The 200mm bore x 10m static conductive air ducting (SAFD20/10-EX) allows the use of the medium air mover (PRG318) with fuel tanks where a connecting wing adaptor assembly (PRG265T1) is inserted into the tank panel in place of an aircraft tank access cover. See Figure 5, Figure 6, Figure 7 and Figure 9. Alternatively, the 200mm bore x 10m static conductive air ducting (SAFD20/10-EX) can be placed directly into the fuel tank access holes. The 200mm bore static conductive air ducts are connected to 200mm to 200mm duct y-adaptors (SAFD20/YC). The y-adaptors are in turn connected to the 200mm bore conductive air ducting depending upon usage (as shown in Figure 8 for example). Additionally, the 200mm bore x 10m static conductive air ducting (SAFD20/10-EX) is used to vent the air mover exhaust flow away from the working area safely, as shown in Figure 5. It may also be used to draw in fresh air for the air mover to ventilate a tank area as shown in Figure 8. Lengths of 200mm bore x 10m static conductive air ducting (SAFD20/10-EX) may be joined together by means of couplings (SAFD20/CU) as required to achieve the required length. See Figure 2, Figure 3 and Figure 4 for the correct method. The strap is tightened by levering the ratchet s lever back and forth. To release the strap, first depress the UNLOCK button against the base of the handle and then move the handle all the way until it has swung through 180 to lay flat, fully open. Then pull the strap off the crank to slacken the strap. See Figure 4. Safety notes: During operation, ensure that the static conductive air ducting and air mover when deployed are placed in such a way that they do not become a hazard to other persons. 2.5 Fuel tank wing adaptor assembly The wing adaptor assemblies (PRG265T1) take the place of the aircraft tank access cover and allow for connection of the 200mm bore x 10m static conductive air ducting (SAFD20/10-EX). Connection to the air mover inlet is via the 200mm bore static conductive air ducting. Page 4 Issue 1

9 Safety note: When replacing the aircraft fuel tank access cover with a wing adaptor assembly, take care not to damage the seal within the wing. 2.6 Compressed air hose Air connection to the large (PRG317) and medium (PRG318) air movers is via a ¾ bore x 15m yellow hose (PRG272), complete with quick connectors. Safety notes: When using the compressed air hose make sure that you are aware of other persons in the area. Correctly connect the couplings before pressurising the hose. Make sure that the hose is de-pressurised before disconnecting the hose. Issue 1 Page 5

10 2.7 Operating instructions medium air mover (PRG318) 1) Check all equipment for damage before use. Do not use damaged equipment. 2) Deploy the kit alongside the aircraft where the fuel tank access is required. 3) Make sure that that the yellow air hose assembly (PRG272) can be deployed from the intended position of the medium air mover (PRG318) to the compressed air supply point. 4) Make sure that the compressed air control valve is shut before connecting to the available compressed air supply. 5) Check that the ambient conditions are suitable for fuel tank ventilation and that the correct authorities have been obtained. 6) Select and attach the appropriate lengths of static conductive air ducting (SAFD20/10-EX), joining sections using the y-adaptors (SAFD20/YC) and couplings (SAFD20/CU) as required to achieve the required configuration. The method of overlapping ducts at the couplings is described in Figure 2, Figure 3 and Figure 4. Figure 2 Connecting 200mm antistatic ducts using the SAFD20/CU coupling Page 6 Issue 1

11 Figure 3 200mm ducts connected with SAFD20/CU coupling Figure 4 200mm antistatic ducting strap release 7) Position the medium air mover (PRG318) adjacent to the fuel tank that is to be ventilated and connect the 200mm bore static conductive air ducting (SAFD20/10-EX) to its inlet. Issue 1 Page 7

12 Safety note: Dependent on the volume of airflow achieved, the air mover may need to be restrained against the reaction force generated. 8) The medium air mover (PRG318) can be used in the configurations shown in Figure 5, Figure 6 and Figure 7. Remove the fuel tank access cover(s) and store safely. At least one other cover should be removed to provide a through flow of air in the fuel tank. Removing further covers will quicken the operation. Attach the wing adaptor with clamps (PRG265T1) and connect the 200mm bore static conductive air ducting (SAFD20/10-EX) to the wing adaptor. Alternatively position the 200mm bore static conductive air ducting (SAFD20/10-EX) inlets within the tank to be ventilated (as shown in Figure 8 for example). 9) Run out and connect a grounding cable to the medium air mover (PRG318). Safety note: Air movers that operate on the Venturi principle can generate considerable amounts of static electricity, as can the movement of air through the ducting. 10) Take the ¾ x 15m yellow compressed air hose (PRG272) and connect one end to the appropriate compressed air distribution point and the other end to the medium air mover s (PRG318) air inlet. 11) Clear the area directly in front of the medium air mover s (PRG318) exhaust duct and downwind of it. 12) Start the compressor or turn on the workshop air. Check all connections for leaks. 13) After a suitable period, shut down the medium air mover (PRG318) and sample the air quality in the fuel tank. Continue ventilating and sampling until the correct conditions for entry are achieved. 14) The medium air mover (PRG318) may now be left in place and run using a muchreduced inlet air pressure to provide sweet air movement throughout the tank whilst work takes place. Alternatively, you may reverse the medium air mover (PRG318) in the ducting arrangement to provide forced ventilation of sweet air as shown in Figure 8. Make sure that you turn off the compressed air supply before uncoupling and reconnecting the medium air mover in the opposite direction. 15) When the task is complete, shut off the compressed air supply at the supply point. Allow sufficient time for residual air to drain from the air hose (PRG272) and then disconnect the air hose and return it to its storage location. 16) Remove the ducting (SAFD20/10-EX) from the medium air mover (PRG318) and from the wing adaptors (PRG265T1) or fuel tank as applicable. 17) Disconnect all ducting (SAFD20/10-EX) from couplings (SAFD20/CU) and y-adaptors (SAFD20/YC). Page 8 Issue 1

13 18) Disconnect the grounding cable from the medium air mover (PRG318) and store. 19) Clean the medium air mover (PRG318), wing adaptors (PRG265T1) and y-adaptors (SAFD20/YC). 20) Compress the flexible ducting (SAFD20/10-EX) using the straps provided, as shown in Figure 10, so that it can be returned to its storage bags. 21) Return the modular air mover kit (PRG434) to storage. Figure 5 Single wing tank purging arrangement (medium air mover) Issue 1 Page 9

14 Figure 6 Dual wing tank purging arrangement (medium air mover) Page 10 Issue 1

15 Figure 7 Schematic of triple wing tank purging arrangement Issue 1 Page 11

16 Figure 8 Wing tank and centre tank ventilation arrangement Page 12 Issue 1

17 2.8 Operating Instructions large air mover (PRG317) Purge-Air Modular Air Mover Kit (PRG434) 1) Check all equipment for damage before use. Do not use damaged equipment. 2) Deploy the kit alongside the aircraft where the fuel tank access is required. 3) Make sure that that the yellow air hose assembly (PRG272) can be deployed from the intended position of the large air mover (PRG318) to the compressed air supply point. 4) Make sure that the compressed air control valve is shut before connecting to the available compressed air supply. 5) Check that the ambient conditions are suitable for fuel tank ventilation and that the correct authorities have been obtained. 6) Select and attach the appropriate lengths of static conductive air ducting (SAFD20/10-EX), joining sections using the y-adaptors (SAFD20/YC) and couplings (SAFD20/CU) as required to achieve the required configuration. The method of overlapping ducts at the couplings is described in Figure 2, Figure 3 and Figure 4. 7) Position the large air mover (PRG317) adjacent to the fuel tank that is to be ventilated and connect the 200mm bore static conductive air ducting (SAFD20/10-EX) to its inlet. Safety note: Dependent on the volume of airflow achieved, the air mover may need to be restrained against the reaction force generated. 8) The large air mover (PRG317) can be used in the configuration shown in Figure 9. Remove the fuel tank access cover(s) and store safely. At least one other cover should be removed to provide a through flow of air in the fuel tank. Removing further covers will quicken the operation. Attach the wing adaptor with clamps (PRG265T1) and connect the 200mm bore static conductive air ducting (SAFD20/10-EX) to the wing adaptor. 9) Run out and connect a grounding cable to the large air mover (PRG317). Safety note: Air movers that operate on the Venturi principle can generate considerable amounts of static electricity, as can the movement of air through the ducting. 10) Take the ¾ x 15m yellow compressed air hose (PRG272) and connect one end to the appropriate compressed air distribution point and the other end to the large air mover s (PRG317) air inlet. 11) Clear the area directly in front of the large air mover s (PRG317) exhaust duct and downwind of it. 12) Start the compressor or turn on the workshop air. Check all connections for leaks. Issue 1 Page 13

18 13) After a suitable period, shut down the large air mover (PRG317) and sample the air quality in the fuel tank. Continue ventilating and sampling until the correct conditions for entry are achieved. 14) The large air mover (PRG317) may now be left in place and run using a muchreduced inlet air pressure to provide sweet air movement throughout the tank whilst work takes place. Alternatively, the medium air mover (PRG318) can be used in the ducting arrangement to provide forced ventilation of sweet air as shown in Figure 8. Make sure that you turn off the compressed air supply before uncoupling the large air mover (PRG317) and reconnecting the medium air mover to circulate air in the opposite direction. 15) When the task is complete, shut off the compressed air supply at the supply point. Allow sufficient time for residual air to drain from the air hose (PRG272) and then disconnect the air hose and return it to its storage location. 16) Remove the ducting (SAFD20/10-EX) from the large air mover (PRG317) and from the wing adaptors (PRG265T1) or fuel tank as applicable. 17) Disconnect all ducting (SAFD20/10-EX) from couplings (SAFD20/CU) and y-adaptors (SAFD20/YC). 18) Disconnect the grounding cable from the large air mover (PRG317) and store. 19) Clean the large air mover (PRG317), wing adaptors (PRG265T1) and y-adaptors (SAFD20/YC). 20) Compress the flexible ducting (SAFD20/10-EX) using the straps provided, as shown in Figure 10, so that it can be returned to its storage bags. 21) Return the modular air mover kit (PRG434) to storage. Page 14 Issue 1

19 Figure 9 Single wing tank purging arrangement (large air mover) Issue 1 Page 15

20 Figure 10 Ducting storage Page 16 Issue 1

21 3 Annual maintenance 3.1 General Never use any component of the modular air mover kit that has suffered damage. Check for electrical grounding continuity. 3.2 Large and medium air movers (PRG317 and PRG318) Check for damage, ensure correct operation and clean. Check the integrity of the static bonding cable if fitted. 3.3 Static conductive air ducting, couplings and y-adaptors (SAFD20/10-EX, SAFD20/CU, SAFD20/YC) Check the lengths of ducting for damage. Check couplings and y-adaptors for damage that prevents airtight sealing during operation. Clean couplings and y-adaptors. Check straps for damage and ensure correct operation. 3.4 Fuel tank wing adaptor assemblies (PRG265T1) Check for damage and clean. Check the condition of the fixings and seals. 3.5 Air hose (PRG272) Check for damage to the hose and couplings. Issue 1 Page 17

22 4 Further information If you require any further information or advice when using this product please contact our Customer Support Unit: Telephone: +44 (0) Fax: +44 (0) For details of our service centres around the world please visit You can scan the quick response (QR) code below with your smart phone or tablet to rapidly visit our website. Page 18 Issue 1

BLAST-IT-ALL PRESSURE BLAST CABINET

BLAST-IT-ALL PRESSURE BLAST CABINET LARRY HESS AND ASSOCIATES, INC 185 PIPER LANE / SALISBURY, NC 28147 PHONE: 1-800-535-2612 / FAX: 1-704-638-9311 WWW.BLAST-IT-ALL.COM BLAST-IT-ALL PRESSURE BLAST CABINET NOTE: It is the responsibility of

More information

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER 2001927 Prepared by: 860 Douglas Way PO Box 530 Natural Bridge Station, VA 24579 1 1.0 SCOPE: This

More information

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER 2001829 OPERATIONS AND MAINTENANCE MANUAL Prepared by: 860 Douglas Way PO Box 530 Natural Bridge Station, VA 24579 1.0 SCOPE: This Operations and Maintenance

More information

Port-A-Cool unit. Pneumatic Owner s Manual. series manufactured by port-a-cool, llc FOR PNEUMATIC MODELS PAC2K36AD, PAC2K24AD, PAC2K16AD

Port-A-Cool unit. Pneumatic Owner s Manual. series manufactured by port-a-cool, llc FOR PNEUMATIC MODELS PAC2K36AD, PAC2K24AD, PAC2K16AD Port-A-Cool unit series 2000 Pneumatic Owner s Manual FOR PNEUMATIC MODELS PAC2K36AD, PAC2K24AD, PAC2K16AD manufactured by port-a-cool, llc PORT-A-COOL unit OWNERS MANUAL PNEUMATIC MODELS PAC2K36AD, PAC2K24AD,

More information

WARNING THE MAGNUM PRESSURE BLAST CABINET

WARNING THE MAGNUM PRESSURE BLAST CABINET THE MAGNUM PRESSURE BLAST CABINET NOTE: It is the responsibility of the user to read and understand this manual and to provide a safe work environment for any operator. No representation is intended as

More information

PORTABLE SMART WASHER

PORTABLE SMART WASHER PORTABLE SMART WASHER User Guide Introduction Thank you for purchasing our Portable Smart Washer, and welcome to the Ivation family. This user manual is meant to offer you a brief walkthrough of the device

More information

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER OPERATING MANUAL MODEL AIR 500TM AIR DRYER Puregas, LLC 226-A Commerce St. Tel: 800-52-535 Broomfield, Colorado Fax: 303-657-2205 P/N P0255 REV A, 02/9/4 TABLE OF CONTENTS.0 GENERAL... 3 2.0 SPECIFICATIONS...

More information

CONFINED SPACE VENTILATION

CONFINED SPACE VENTILATION CONFINED SPACE VENTILATION Version 1.0 1 DESIGNING THE FUTURE At Pearson Industries we understand that tough jobs require tougher tools, and for this industry, our fans have been designed to outperform

More information

Model DAC12004RC. Please read this manual carefully before use and keep it for future reference.

Model DAC12004RC. Please read this manual carefully before use and keep it for future reference. Model DAC12004RC Please read this manual carefully before use and keep it for future reference. CONTENTS. Page Introduction........................................................ 1 Features...........................................................

More information

Caresaver Universal Refrigerant Recovery Unit

Caresaver Universal Refrigerant Recovery Unit Operation Manual Caresaver Universal Refrigerant Recovery Unit 2 CONTENTS CHAPTER 1 INTRODUCTION AND OVERVIEW Specifications 3 Health and Safety 4-5 Component Location and Identification 6-9 CHAPTER 2

More information

Permission granted to reproduce for educational use only. Describe the problems caused by excess

Permission granted to reproduce for educational use only. Describe the problems caused by excess Chapter 16 Conditioning and Distribution of Compressed Air Controlling Dirt, Moisture, Temperature, and Pressure 1 Objectives Compare the various methods used to remove dirt from ambient air entering the

More information

PRO 2000i LOW LEVEL DEPOSITOR

PRO 2000i LOW LEVEL DEPOSITOR DEPOSITORS AND AUTOMATED CAKE PRODUCTION SYSTEMS PRO 2000i LOW LEVEL DEPOSITOR OPERATION AND SPARE PARTS MANUAL Serial No. PR2L- (Please quote this number when ordering spares, and making service calls)

More information

SHOT BLAST CABINET USER INSTRUCTIONS. Model No: CSB20B. Part No: GC05/13

SHOT BLAST CABINET USER INSTRUCTIONS. Model No: CSB20B. Part No: GC05/13 SHOT BLAST CABINET Model No: CSB20B Part No: 7640110 USER INSTRUCTIONS GC05/13 INTRODUCTION Thank you for purchasing this CLARKE Shot Blast Cabinet which is designed for professional workshop use. Please

More information

OPERATING INSTRUCTIONS & Safety Guide. HafcoVac Compressed Air Industrial Vacuum Product Line

OPERATING INSTRUCTIONS & Safety Guide. HafcoVac Compressed Air Industrial Vacuum Product Line OPERATING INSTRUCTIONS & Safety Guide HafcoVac Compressed Air Industrial Vacuum Product Line Introduction HafcoVac A product of Hafco Foundry and Machine Company, Inc. 301 Greenwood Avenue Midland Park,

More information

BLAST-IT-ALL BUMPER BLASTER

BLAST-IT-ALL BUMPER BLASTER LARRY HESS AND ASSOCIATES, INC 185 PIPER LANE / SALISBURY, NC 28147 PHONE: 1-800-535-2612 / FAX: 1-704-638-9311 WWW.BLAST-IT-ALL.COM BLAST-IT-ALL BUMPER BLASTER SUCTION BLAST CABINET NOTE: It is the responsibility

More information

ACS.CCLP1 PD SAFETY ASSESSMENT CRITERIA INITIAL & RE-ASSESSMENT DOMESTIC LPG PERMANENT DWELLINGS

ACS.CCLP1 PD SAFETY ASSESSMENT CRITERIA INITIAL & RE-ASSESSMENT DOMESTIC LPG PERMANENT DWELLINGS ACS.CCLP1 PD SAFETY ASSESSMENT CRITERIA INITIAL & RE-ASSESSMENT DOMESTIC LPG PERMANENT DWELLINGS Issue 7 ACS.SMB 1 CCLP1 PD INITIAL & RE-ASSESSMENT Introduction Tests gas safety competence in core domestic

More information

MANUAL COVER. To expedite parts ordering or technical questions, please include your Model and Serial Number listed below in all correspondence.

MANUAL COVER. To expedite parts ordering or technical questions, please include your Model and Serial Number listed below in all correspondence. MANUAL COVER We at Larry Hess & Associates, Inc. would like to take this opportunity to thank you for your patronage. The machine you have purchased has been manufactured and assembled in the USA with

More information

COMMERCIAL GAS AND ELECTRIC STACKED WASHER/ DRYER INSTALLATION INSTRUCTIONS

COMMERCIAL GAS AND ELECTRIC STACKED WASHER/ DRYER INSTALLATION INSTRUCTIONS COMMERCIAL GAS AND ELECTRIC STACKED WASHER/ DRYER INSTALLATION INSTRUCTIONS MODELS MLG19PD, MLE19PD The installation, including a proper exhaust system, is the responsibility of the owner. LEAVE THESE

More information

Quartz. Thermo. Concealed shower valve with adjustable head. Quartz Thermo installation guide page 1

Quartz. Thermo. Concealed shower valve with adjustable head. Quartz Thermo installation guide page 1 Quartz Thermo Concealed shower valve with adjustable head Quartz Thermo installation guide page 1 Shower systems Components Quartz Thermo built-in shower valve with adjustable head QZ3111 Quartz Thermo

More information

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System 1 Revised 11/18/10 2320 Lakecrest Drive, Pekin IL 61554 PH. (888) 747-4389 Fax (309) 495-0625 Website: www.getzequipment.com LIMITED

More information

Installation guide Sahara & Sahara Plus

Installation guide Sahara & Sahara Plus Installation guide Sahara & Sahara Plus Installation requirements. Components for Billi Sahara 310, 320, 360 & 3120 Models Before commencing installation, ensure you have identified the following. 1. Underbench

More information

KIT CONTENTS Ref Qty Part Description Part Number

KIT CONTENTS Ref Qty Part Description Part Number CAB HEATER KIT P/N 2879967 APPLICATION RANGER 570 AND RANGER 570 CREW BEFORE YOU BEGIN Read these instructions thoroughly and make sure all parts and tools are accounted for. Please retain these installation

More information

Operation Manual. Airbrush Airbrush-Spray Booth Compressor Suction Unit Paint E420

Operation Manual. Airbrush Airbrush-Spray Booth Compressor Suction Unit Paint E420 Operation Manual Airbrush Airbrush-Spray Booth Compressor Suction Unit Paint E420 Read and follow the operating instructions and safety information before using for the first time. Technical changes reserved!

More information

Installation and Servicing Instructions. Alpha GasSaver GS-2

Installation and Servicing Instructions. Alpha GasSaver GS-2 Installation and Servicing Instructions Alpha GS- Passive Flue Gas Heat Recovery Device (PFGHRD) for use with an Alpha Condensing Combination s IMPORTANT: Read these instructions BEFORE installing the

More information

Drying Cabinet Installation and Operating Manual

Drying Cabinet Installation and Operating Manual Drying Cabinet Models:- ETS-1900H ETS-1900TR CONTENTS ABOUT THE USER MANUAL Page 2 IDENTIFICATION DATA PLATE Page 2 IMPORTANT SAFETY INSTRUCTIONS Page 3 INSTALLATION INSTRUCTIONS Page 4 OPERATING INSTRUCTIONS

More information

Section 8: Supplements

Section 8: Supplements F L I G H T Section 8: Supplements 8.41 SAFIRE BURNER APPROVED BY EASA UNDER APPROVAL NUMBER 10045746 8.41.1 GENERAL INFORMATION This supplement shall be inserted in the Flight Manual, in Section 8: Supplements

More information

REMOVE AND INSTALL AIR CLEANER ASSEMBLY

REMOVE AND INSTALL AIR CLEANER ASSEMBLY REMOVE AND INSTALL AIR CLEANER ASSEM 50 DISASSEM AND ASSEM- REMOVE AND INSTALL AIR CLEANER ASSEM Cover Connector Air cleaner assembly Place the machine on a level ground, lower the work equipment to the

More information

Smoke Vent with Manual Winch. Installation, Operation and Maintenance

Smoke Vent with Manual Winch. Installation, Operation and Maintenance Smoke Vent with Manual Winch I. Overview Smoke vents are used, upgraded with manual winches, typically installed in theater applications. The winch is used to manually close the smoke vent from a remote

More information

Aquamixa. Thermo. Thermostatic shower valve with manual bath fill

Aquamixa. Thermo. Thermostatic shower valve with manual bath fill Aquamixa Thermo Thermostatic shower valve with manual bath fill Aquamixa Thermo thermostatic shower valve with manual bath fill installation instuctions page 1 Shower systems Aquamixa Thermo (300.01) with

More information

Installation and Servicing Instructions. Alpha GasSaver GS-1

Installation and Servicing Instructions. Alpha GasSaver GS-1 Installation and Servicing Instructions Alpha GS-1 Passive Flue Gas Heat Recovery Device (PFGHRD) for use with an Alpha CD Condensing IMPORTANT: Read these instructions BEFORE installing the boiler For

More information

ON TRACK Reprocessing In-service / Competency for CF/PCF/GIF Endoscopes (EVIS, EXERA, EXERA II)

ON TRACK Reprocessing In-service / Competency for CF/PCF/GIF Endoscopes (EVIS, EXERA, EXERA II) THIS CHECKLIST IS DESIGNED FOR USE SOLELY AS A CUSTOMER EDUCATIONAL TOOL, AND IS NOT INTENDED TO REPLACE OR ANY WAY MODIFY THE OLYMPUS INSTRUCTION MANUAL/REPROCESSING MANUAL. BE SURE TO FOLLOW THE DETAILED

More information

Portable Air Conditioner User Manual Read and save these instructions before use

Portable Air Conditioner User Manual Read and save these instructions before use Portable Air Conditioner User Manual Read and save these instructions before use Email: info@jmatek.com Web: www.jmatek.com Model : MN09 Series: MN09CES, MN09CESBB, MN09CESWW, MN09CHES, MN09CHESBB, MN09CHESWW

More information

HG-1500 Ozone Generator

HG-1500 Ozone Generator HG-1500 Ozone Generator Manual Ozone Solutions Thanks You For Purchasing Our Products Ozone Solutions, Inc. HG-1500 Ozone Generator With proper care and maintenance, this device should give you years of

More information

Mobile Air Conditioner Instruction Manual Model TC-N9KM

Mobile Air Conditioner Instruction Manual Model TC-N9KM Mobile Air Conditioner Instruction Manual Model TC-N9KM Please read and retain these instructions for future reference SPECIFICATION Model no. Cooling capacity Power/Ampere consumption for cooling* Air

More information

TECHNICAL SERVICE GUIDE

TECHNICAL SERVICE GUIDE GE Consumer Home Services Training TECHNICAL SERVICE GUIDE LOKRING Connectors Pub # 31-9067 01/01 IMPORTANT SAFETY INFORMATION Before cutting or using a torch on refrigerant tubes, recover the refrigerant

More information

ColorMax Cyclone Cleaning Kit

ColorMax Cyclone Cleaning Kit Instruction Sheet P/N 637 0 WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Description See

More information

Moduflex. Desiccant Air Dryer P3TJA13A1AN - P3TJA13A7AN. USER GUIDE (Original Language) Dry Air System NL DE FR FI SV NO DA EL ES PT IT PL SK CS ET HU

Moduflex. Desiccant Air Dryer P3TJA13A1AN - P3TJA13A7AN. USER GUIDE (Original Language) Dry Air System NL DE FR FI SV NO DA EL ES PT IT PL SK CS ET HU Moduflex Dry Air System Desiccant Air P3TJA13A1AN - P3TJA13A7AN EN USER GUIDE (Original Language) NL DE FR FI SV NO DA EL ES PT IT PL SK CS ET HU LV LT RU SL TR MT CONTENTS 1 Safety Information...2 1.1

More information

NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials

NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials Fire Preven4on Officers Associa4on of Bri4sh Columbia 2013 Annual Seminar Kelowna, Bri4sh Columbia May 9, 2013 NFPA 33 Scope

More information

Eliminator TotalGuard Installation Manual

Eliminator TotalGuard Installation Manual Eliminator TotalGuard Installation Manual Central Heating Filter Version 2 January 2016 IMPORTANT Please retain these instructions for reference during servicing Page 1 Eliminator TotalGuard Instructions

More information

Linkam Scientific Instruments USER GUIDE TS1500 TS1200 TS1000. High Temperature Stage

Linkam Scientific Instruments USER GUIDE TS1500 TS1200 TS1000. High Temperature Stage Linkam Scientific Instruments TS1500 TS100 TS1000 High Temperature Stage USER GUIDE Contents Before Setting Up your Equipment... 3 Important Notice... 4 Warranty... 4 Technical Support... 4 Equipment Maintenance...

More information

WHHR Midi & Midi Lite

WHHR Midi & Midi Lite WHHR Midi & Midi Lite Residential Whole House Heat Recovery Units with Low Energy EC Motors Optional - Integral LCD Installation, Operating and Maintenance Instructions Image of model with LCD screen Page

More information

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278

Illustration shows item no Z Original operating manual. Operating manual. BlueMobil eco. Item no: Z-3278 Illustration shows item no Z-3278 Operating manual BlueMobil eco Item no: Z-3278 Original operating manual Important Copyright It is essential that you read this manual thoroughly before the initial operation

More information

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace TECHNICAL SPECIFICATIONS M3RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 90+ AFUE Input 60,000 & 80,000 Btuh The high efficiency downflow gas furnace is especially

More information

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Purge Ventilation Unit. Product Manual. ventilation systems TP625 EN Purge Ventilation Unit TP625 Product Manual ventilation systems Warnings, Safety Information and Guidance Important Information Important: read these instructions fully before the installation of this

More information

ALB30634 Air Operated Fuel Retriever

ALB30634 Air Operated Fuel Retriever ALB30634 Air Operated Fuel Retriever ONLY USE IN A WELL VENTILATED AREA OR WITH FUME EXTRACTION Read instructions and safety warnings before use of this product. The product should only be used in conjunction

More information

Empura Water Filter. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Empura Water Filter. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts Empura Water Filter Installation Instructions & User Guide Please keep these instructions for future reference and request of replacement parts Important Safety Information Please read these instruction

More information

ComPact Air Drive II USER S MANUAL

ComPact Air Drive II USER S MANUAL ComPact Air Drive II USER S MANUAL R Original Instruments and Implants of the Association for the Study of Internal Fixation AO ASIF TABLE OF CONTENTS Page ComPact Air Drive II Specifications... 2 Attachments...

More information

INSTALLATION INSTRUCTIONS GPM SERIES LOOP PUMP MODULES

INSTALLATION INSTRUCTIONS GPM SERIES LOOP PUMP MODULES INSTALLATION INSTRUCTIONS GPM SERIES LOOP PUMP MODULES Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving, ahead just as planned. Manual: 2100-212A Supersedes: 2100-212 File: Tab 8

More information

Design Specifications for Panda 900A Car Spray Booth

Design Specifications for Panda 900A Car Spray Booth Design Specifications for Panda 900A Car Spray Booth Panda Spray Booths are designed and manufactured to suit the various industrial requirements such as, trucking, marine, agriculture, construction machinery,

More information

Rambo CAST IRON RING BURNERS OPERATING INSTRUCTIONS. C40LP 3 Ring Burner C50LP 4 Ring Burner

Rambo CAST IRON RING BURNERS OPERATING INSTRUCTIONS. C40LP 3 Ring Burner C50LP 4 Ring Burner Rambo CAST IRON RING BURNERS OPERATING INSTRUCTIONS C20LP 1 Ring Burner C30LP 2 Ring Burner C40LP 3 Ring Burner C50LP 4 Ring Burner IMPORTANT: READ THESE INSTRUCTIONS FOR USE CAREFULLY. KEEP THESE INSTRUCTIONS

More information

OWNER S GUIDE TYPE A TYPE C TYPE B TYPE E TYPE F TYPE D COOL FAN OFF. CA Series << FAN SPEED COOL FAN AUTO SLEEP TIMER FAN SPEED

OWNER S GUIDE TYPE A TYPE C TYPE B TYPE E TYPE F TYPE D COOL FAN OFF. CA Series << FAN SPEED COOL FAN AUTO SLEEP TIMER FAN SPEED ON/ RESET RESET OWNER S GUIDE 1. Identify, using the pictures below, which controller type you have installed and turn to the relevant page for the operating instructions. 2. General information applies

More information

OH&S WORKPLACE ASSESSMENT INSPECTION CHECKLIST

OH&S WORKPLACE ASSESSMENT INSPECTION CHECKLIST OH&S WORKPLACE ASSESSMENT INSPECTION CHECKLIST Organisational Unit / Workplace: Person undertaking inspection: Date inspected: The findings from workplace inspections and safety audits should be submitted

More information

Sip Vacuum Cleaner 1400/35 Wet & Dry

Sip Vacuum Cleaner 1400/35 Wet & Dry Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

SERVICE BULLETIN A

SERVICE BULLETIN A 1. PLANNING INFORMATION A. Effectivity: Dassault Falcon 10 aircraft which have installed R-134a Upgrade Kit SZ59K-R134 before August 8, 2002. B. Reason: Upgrade kits before August 8, 2002 did not include

More information

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death. Please Read: Safety Precautions DC AC In order to ensure that this product is used safely, be sure that you read and understand the following precautions fully and use the product only as directed. Be

More information

ENGLISH INSTALLATION AND USER S MANUAL FRENCH NOTICE D INSTALLATION ET D UTILISATION ITALIAN MANUALE D ISTRUZIONE

ENGLISH INSTALLATION AND USER S MANUAL FRENCH NOTICE D INSTALLATION ET D UTILISATION ITALIAN MANUALE D ISTRUZIONE ENGLISH INSTALLATION AND USER S MANUAL FRENCH NOTICE D INSTALLATION ET D UTILISATION ITALIAN MANUALE D ISTRUZIONE 1 INSTALLATION AND USER S MANUAL CONTENT INTRODUCTION 03 SAFETY PRECAUTION 03 SPECIFICATION

More information

Dimplex Air Conditioner DAC 12000R

Dimplex Air Conditioner DAC 12000R Dimplex Air Conditioner DAC 12000R CONTENTS. Page Introduction........................................................ 2 Features........................................................... 2 Specification........................................................

More information

Outdoor Tabletop Heater TTH20 Series

Outdoor Tabletop Heater TTH20 Series Outdoor Tabletop Heater TTH20 Series FEATURES: The ideal solution for extending the outdoor entertaining season Creates a stylish and attractive ambience Casts an approximate 1 to 1.5 metre circle of radiant

More information

OPERATING MANUAL 12 AXIAL FANS

OPERATING MANUAL 12 AXIAL FANS Manual No. BLWR051 Rev. 0 April 2015 OPERATING MANUAL 12 AXIAL FANS MODELS: CVF-12AC CVF12CAN15 CVF12CAN25 Air Systems International, Inc. 829 Juniper Crescent, Chesapeake, Va, 23320 Telephone (757) 424-3967

More information

How to Build A State-of-the-Art, High Yielding Aeroponic Growing System

How to Build A State-of-the-Art, High Yielding Aeroponic Growing System How to Build A State-of-the-Art, High Yielding Aeroponic Growing System Table Of Contents: Page I. Introduction 3 a. What is Aeroponics? 3 b. Why is aeroponics used? 3 II. What You Will Need and Where

More information

ACT Cartridge Dust Collector

ACT Cartridge Dust Collector IOM-101-1 ACT Cartridge Dust Collector Installation and Operation Manual ACT Dust Collectors CAUTION! Accidents happen, be careful and always follow all local and federal regulations! Fires and explosions

More information

Service Bulletin Trucks Date Number Page

Service Bulletin Trucks Date Number Page Mack Trucks, Inc. Allentown, PA USA (Does not apply to Mack Trucks Australia) (Supersedes SB215025 dated 03/27/07) Service Bulletin Trucks Date Number Page 11/04/08 SB215025 1(25) Cooling System Revisions

More information

www.compressedairsystems.com PURIFICATION SOLUTIONS D-Series1 ultra-high purity compressed air dryers flow capacity: 3-177 scfm (5-301 Nm /hr) 3 D 1 D-Series 1 ultra-high purity compressed air dryers D

More information

PROPANE GAS HEATER MODEL NO: GRH35 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: GC01/14

PROPANE GAS HEATER MODEL NO: GRH35 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: GC01/14 PROPANE GAS HEATER MODEL NO: GRH35 PART NO: 6920016 OPERATION & MAINTENANCE INSTRUCTIONS GC01/14 INTRODUCTION Thank you for purchasing this CLARKE Gas Heater. designed for industrial use only, i.e. NOT

More information

AIR FILTER + REGULATOR + LUBRICATOR AIR FILTER. Series : V050, V100, V200, V250, V300

AIR FILTER + REGULATOR + LUBRICATOR AIR FILTER. Series : V050, V100, V200, V250, V300 AIR FILTER + REGULATOR + LUBRICATOR AIR FILTER Series : V00, V00, V00, V0, V00 AIR FILTER FEATURES: High flow Capacity Shatter- Proof polycarbonate bowl with bowl guard Minimum Pressure drop Choice of

More information

SVF-8DC. Manual No. BLWR007 Rev. 3 February 2014

SVF-8DC. Manual No. BLWR007 Rev. 3 February 2014 Manual No. BLWR007 Rev. 3 February 2014 OPERATING MANUAL SVF-8AC SVF-6ACAN SVF-15ACAN SVF-25ACAN MODELS: SVF-8DC SVF-6DCAN SVF-15DCAN SVF-25DCAN Air Systems International, Inc. 829 Juniper Crescent, Chesapeake,

More information

SERVICE ASSISTANT OVERVIEW FDSI Online Training

SERVICE ASSISTANT OVERVIEW FDSI Online Training Author: Dale T. Rossi Online Editor: Zachary Williams SERVICE ASSISTANT OVERVIEW FDSI Online Training May 5, 2009 Table Service Assistant Description... 2 Installing the Main Unit... 3 Ambient Temperature...

More information

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www.eipl.co.uk Page 1 of 11 UNPACKING Carefully remove the DD200 dehumidifier unit from its transit box and visually check for signs of transit damage. If there

More information

Verde GSE PCA Bridge and Ground Mount Units 30/45/60/90/120 Tons. Installation and Maintenance Manual

Verde GSE PCA Bridge and Ground Mount Units 30/45/60/90/120 Tons. Installation and Maintenance Manual Verde GSE PCA Bridge and Ground Mount Units 30/45/60/90/120 Tons Installation and Maintenance Manual Rev. 09/17/2016 Table of Contents SAFETY... 3 GENERAL DESCRIPTION... 4 MOVING AND STORAGE... 4 INITIAL

More information

ASSEMBLY & OPERATING INSTRUCTIONS

ASSEMBLY & OPERATING INSTRUCTIONS SD-BASIC SPRAY DRYER ASSEMBLY & OPERATING INSTRUCTIONS 1) Introduction 2) Safety / COSHH 3) General Safety Rules 4) Components Included 5) Packing List 6) Connection to Electrical Supply 7) Assembly and

More information

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified Thank you for purchasing our fully-automatic gas-fired tankless water heater. Please completely read this Manual

More information

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL 456 Creamery Way, Exton, PA 19341, USA Phone: 610.524.8800 Fax: 610.524.8807 Email: info@refrigerantid.com www.refrigerantid.com Page

More information

Your Pope Simple Set Automatic Tap Timer

Your Pope Simple Set Automatic Tap Timer Your Pope Simple Set Automatic Tap Timer gives you all the convenience of set and forget garden watering. Just select how long and how often you want to water your garden and the Pope Simple Set Automatic

More information

OPERATION AND MAINTENANCE MANUAL

OPERATION AND MAINTENANCE MANUAL OPERATION AND MAINTENANCE MANUAL ADU-10CF (NSN: 6520-01-456-7170) Part 1 of 2 P.O. Box 1548 Woodinville, WA 98072-1548 1-800-426-5913 * 425-487-3157 * Fax: 425-487-2608 email: info@aseptico.com * Internet:

More information

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS 6 th June 2006 Page 1 WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C, 140 AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS Please read and follow all these instructions carefully before proceeding

More information

compressed air or left to consume air even when the associated production machine has been turned off.

compressed air or left to consume air even when the associated production machine has been turned off. SToP operating BlIND USE A FlowMETER By Ron Marshall for the Compressed Air Challenge c Participants of Compressed Air Challenge s Fundamentals of Compressed Air Systems seminars are usually surprised

More information

Module 7: Air Supply System

Module 7: Air Supply System Terms and Definitions Components of the Air Supply System Basic Functions of the Air Supply System Parts of a Compressor Characteristics of Compressors Loading and Unloading Process Characteristics of

More information

Up-Flow Carbon Installation & Start-Up Guide

Up-Flow Carbon Installation & Start-Up Guide Clean Water Made Easy www.cleanwaterstore.com Up-Flow Carbon Installation & Start-Up Guide Thank you for purchasing a Clean Water System! With proper installation and a little routine maintenance your

More information

CYLINDER NOT INCLUDED

CYLINDER NOT INCLUDED OPERATING INSTRUCTIONS AND OWNER S MANUAL Model # HS125NG / MH125LP / HS125LP READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instructions in a safe place for future reference. Do

More information

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS CORR/GUARD INSTALLATION INSTRUCTIONS This symbol on the nameplate means this product is listed by Underwriters Laboratories Inc. Tested to UL1738 / CAN / ULCS636-08 Listing No. MH26687 Testing No. 11EN

More information

APW-VAP-150P High Pressure Cleaner Operator Manual

APW-VAP-150P High Pressure Cleaner Operator Manual APW-VAP-150P High Pressure Cleaner Operator Manual BEFORE OPERATING THIS APPLIANCE PLEASE READ THESE INSTRUCTIONS CAREFULLY Item Description OVERVIEW 1. High pressure washer 2. On/off switch 3. Water outlet

More information

Parasitic Cysts - Cryptosporidium and Giardia, Chemicals, Heavy Metals, Dissolved Salts, Offensive Tastes and Odours, Sediment, Dirt,

Parasitic Cysts - Cryptosporidium and Giardia, Chemicals, Heavy Metals, Dissolved Salts, Offensive Tastes and Odours, Sediment, Dirt, Aqua-Pure is a market leader in water filtration. In addition to our comprehensive range of Domestic Water Purifiers, we design and manufacture an extensive commercial and industrial range of purification

More information

MeacoCool MC Series Portable Air Conditioner

MeacoCool MC Series Portable Air Conditioner MeacoCool MC Series Portable Air Conditioner Thank you for choosing Meaco, we really do appreciate it INSTRUCTION MANUAL [EN] MC8000 MC8000CH MC9000 MC9000CH MC10000 MC10000CH SAFETY INFORMATION ATTENTION

More information

GASEOUS HYDROGEN SYSTEMS

GASEOUS HYDROGEN SYSTEMS CHAPTER 7 GASEOUS HYDROGEN SYSTEMS SECTION 701 GENERAL 701.1 Scope. The installation of gaseous hydrogen systems shall comply with this chapter and Chapters 30 and 35 of the Fire Compressed gases shall

More information

Overhead Protection System (OPS)

Overhead Protection System (OPS) Overhead Protection System (OPS) OPS (Overhead Protections System) Description An OPS is a re-usable, inflatable safety device that can be lowered or raised into a vessel to provide a safe work environment

More information

Installation Instructions for P/N: Algas-SDI thermostat retrofit kit

Installation Instructions for P/N: Algas-SDI thermostat retrofit kit 151 South Michigan Street, Seattle, WA 98108 U.S.A. Phone: 206-789-5410 Fax: 206-789-5414 Internet: www.algas-sdi.com Installation Instructions for P/N: 41073 Algas-SDI thermostat retrofit kit Field Kit

More information

OPERATING MANUAL AUTOMATIC SPRAY GUN CLEANERS UG7500 SERIES UNI-RAM CORPORATION ONTARIO CANADA PATENTS

OPERATING MANUAL AUTOMATIC SPRAY GUN CLEANERS UG7500 SERIES UNI-RAM CORPORATION ONTARIO CANADA PATENTS OPERATING MANUAL AUTOMATIC SPRAY GUN CLEANERS UG7500 SERIES PATENTS U.S.A. 4,785,836 CANADA 1293909 U.S.A. 5,213,117 ENGLAND EP 0300248 (UK) EUROPE 0300248 ITALY 69760/BE/92 SWEDEN 0300248 GERMANY DE 38

More information

TSS 15/55 Hi-Lift Vacuum

TSS 15/55 Hi-Lift Vacuum TSS 15/55 Hi-Lift Vacuum OPERATOR S MANUAL 2007 ICS, Blount Inc. F/N 71335 Oct 07 TABLE OF TITLE CONTENTS SYMBOLS & LABELS 4 SAFETY 5 TECHNICAL SPECIFICATIONS 6 SET-UP 7 OPERATION 8 MAINTENANCE 9 TROUBLESHOOTING

More information

Dovre 250 Cast Iron Gas Stove

Dovre 250 Cast Iron Gas Stove Dovre 50 Cast Iron Gas Stove NATURAL GAS AND LPG INSTALLATION, SERVICING AND USER INSTRUCTIONS THIS PRODUCT IS FOR USE ONLY IN GREAT BRITAIN AND IRELAND These instructions are to be left with the customer,

More information

Certified to CSA STD. C22.2 No.117

Certified to CSA STD. C22.2 No.117 Certified to CSA STD. C22.2 No.117 1 Trust has to be earned and we will earn yours. Customer happiness is the focus of our business. From the factory to the warehouse, from the sales floor to your home,

More information

Drinking Water Purification Systems

Drinking Water Purification Systems supersedes 200695Cx-2i&o SEAGULL IV X-2KB and X-2KF Drinking Water Purification Systems SEAGULL IV X-2KB SEAGULL IV X-2KF INSTALLATION AND PRODUCT USE GUIDE INSTALLATION INSTRUCTIONS NOTE: Read instructions

More information

Energy Saving Fact Sheet Compressed air

Energy Saving Fact Sheet Compressed air Energy Saving Fact Sheet Compressed air Take the pressure off your energy bills Compressed air is a versatile, flexible and safe way to transmit energy. Almost all industrial businesses use it. In fact,

More information

SAFETY AND OPERATING MANUAL

SAFETY AND OPERATING MANUAL SAFETY AND OPERATING MANUAL HOT WATER ELECTRIC WATER BLASTERS Read Safety & Operating Instructions Before Commencing Operation THESE INSTRUCTIONS MUST BE READ AND ADHERED TO BEFORE OPERATING THIS MACHINE.

More information

INSTALLATION INSTRUCTIONS FOR THROUGH-THE-WALL VENTING COMPONENTS

INSTALLATION INSTRUCTIONS FOR THROUGH-THE-WALL VENTING COMPONENTS OIL FIRED WATER HEATER INSTALLATION AND OPERATING INSTRUCTIONS Read these instructions thoroughly before starting INSTALLATION INSTRUCTIONS FOR THROUGH-THE-WALL VENTING COMPONENTS These instructions apply

More information

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314) DRY AIR SYSTEMS, INC. 2655 Metro Boulevard Maryland Heights, Missouri 63043 (314) 344-1114 fax (314) 344-0677 HD SERIES DRIERS TABLE OF CONTENTS WHY AN AIR DRYER 3 WHAT IS A DESICCANT AIR DRYER 3 Desiccant

More information

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www.eipl.co.uk Page 1 of 15 DD200 PACKAGE CONTENTS Item Description Quantity 10502SS-US Dehumidifier 1 3033807 Free plug 1 TPC356 Manual 1 Page 2 of 15 UNPACKING

More information

Tanis Engine Dehydrator. User s Guide

Tanis Engine Dehydrator. User s Guide Tanis Engine Dehydrator User s Guide Model TED-4010E Tanis Aircraft Products PO Box 117 Glenwood, MN 56334 800-443-2136 320-634-4772 www.tanisaircraft.com Copyright 2007 by Tanis Aircraft Products. All

More information

Heat Exchanger Block Replacement Instructions

Heat Exchanger Block Replacement Instructions Series 1-4 Gas-fired water boiler Heat Exchanger Block Replacement Instructions Ultra-80 S1-4 Heat Exchanger Block Replacement Kit, Part No. 383-500-773 Ultra-105 S1-4 Heat Exchanger Block Replacement

More information

Confined Space Ventilation equipment

Confined Space Ventilation equipment Confined Space Ventilation equipment Often imitated. Never duplicated. At Schaefer, we understand that serious environments call for serious ventilation. That's why we've created products that perform

More information

PAC12H. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

PAC12H. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product. USER MANUAL Portable Air Conditioner and Heater With Heat Pump Technology PAC12H 12,000btu Cool & Heat Portable Air Conditioner Please read this manual carefully prior to operating the product. Please

More information