NECS-Q. Climaveneta Technical Bulletin NECS_Q_1314_3218_201005_GB. INTEGRA unit for 4-pipe systems, air source for outdoor installation

Size: px
Start display at page:

Download "NECS-Q. Climaveneta Technical Bulletin NECS_Q_1314_3218_201005_GB. INTEGRA unit for 4-pipe systems, air source for outdoor installation"

Transcription

1 Climaveneta Technical Bulletin NECS_Q_1314_3218_201005_GB NECSQ r HFC R410A kw INTEGRA unit for 4pipe systems, air source for outdoor installation (The photo of the unit is indicative and may change depending on the model) Refrigerant gas R410A Ef ciency Class A Hydronic unit

2 NECSQ SUMMARY NECSN Product presentation 1.1 Refrigerant gas R410A 1.2 Unique proposal 1.3 Ef ciency (Class A) 1.4 Hydronic unit 2. Unit description 2.1 Standard unit layout 2.2 Certi cation, reference standards 2.3 Tests 2.4 Controller 2.5 Versions 2.6 Accessories 3. Electronic controller 3.1 Control unit with LED display 4. Technical data 4.1 General technical data 4.2 Cooling capacity performance 4.3 Heat pump capacity performance 4.4 Recovery capacity performance 5. Operating range 6. Hydraulic data 6.1 Water ow and pressure drop 7. Hydronic groups (Optional) 8. Electrical data 9. Full load sound level 10. Dimensional drawings 11. Key to hydraulic connections pg. n III pg. n III pg. n III pg. n III pg. n III pg. n 1 pg. n 1 pg. n 1 pg. n 1 pg. n 2 pg. n 2 pg. n 3 pg. n 4 pg. n 4 pg. n 6 pg. n 6 pg. n 12 pg. n 21 pg. n 33 pg. n 42 pg. n 46 pg. n 46 pg. n 47 pg. n 53 pg. n 56 pg. n A1 pg. n A3 Company quality system certi ed to UNI EN ISO 9001 Liability disclaimer This bulletin is not exhaustive about: installation, use, safety precautions, handling and transport. Refer to General Manual for Installation for further informations. This bulletin refers to standard executions, in particular for dimension, weight, electric, hydraulic, aeraulic and refrigerant connections (whereas applicable). Contact Climaveneta Commercial Of ce for further drawings and schemes. Climaveneta declines any liability derived from the bulletin s use. This bulletin is of exclusive property of Climaveneta, and all forms of copy are prohibited. The information contained in this document may be modi ed without prior notice. II NECSQ_1314_3218_201005_GB HFC R410A

3 1. PRODUCT PRESENTATION NECSQ This section contains general information on the NECSQ range of products. For detailed information refer to the speci c sections in this bulletin. 4pipe systems This type of system is suitable for airconditioning buildings that require separate areas to be heated and cooled at the same time. It is combined with centralised solutions capable of producing hot and cold water in the two hydronic circuits of the system, assuring maximum comfort in every room of the building, independently and in any period of the year. From now on, a single intelligent unit is suf cient for the management of these complex systems: INTEGRA. INTEGRA unit for 4pipe systems, air source for outdoor installation The NECSQ series multiuse units are able to simultaneously meet hot and cold water production requests and are thus a valid alternative to traditional systems based on chillers and boilers for applications such as of ce blocks, pools and shopping centres. The advanced control logic, developed by Climaveneta, ensures that heating and cooling loads are perfectly met. When these are simultaneous, the unit exchanges evaporation and condensation heat with the system cooling and heating circuits respectively. When heat loads are not balanced or one of the two are missing, the unit automatically switches to a third heat source which can be air or water according to the model. The NECSQ are units for outdoor installation. For these products. heat is exchanged on the source side by a refrigerantair coils exchanger; it acts as a condensert or as an evaporator according to machine conditions. CA version unify in fact a premium ef ciency level as well as a quiet operation at all working conditions. All standard units can be also provided with the compressors acoustical enclosure that can reduce the sound power level by 2dB(A). Innovative fan management system Climaveneta has designed a new system on how to manage the condensing fans with a complete new structure of the ventilation section (patent pending). This allow to ensure outstanding performances in terms of ef ciency in all the operating conditions, thank to: elimination of the reciprocal dependency on adjacent circuits ability to manage independent defrost cycles on different at different time in different circuits a more accurate fans speed management and, as consequence, a lower power consumption. 1.3 Efficiency (Class A) NECSN units are available in the CA version, with Class A ef ciency levels in the heat pump mode according to the Eurovent performance tables. These units exceed the minimum winter mode ef ciency requirement assuring a COP 3.2, while in the summer mode they assure an EER Hydronic unit The integrated hydronic assembly includes the main hydraulic components, with a low or highhead pump and storage tank. Automatic pump rotation system in the event of a breakdown without interrupting operation (only in units with a twin pump). 1.1 Refrigerant gas R410A The use of R410A has resulted in units offering better energy ef ciency in full respect for the environment (ODP = 0). 1.2 Unique proposal Maximum Reliability Unit with multicircuit chilling section (two to four, depending on the size) designed to ensure maximum ef ciency both at full load and at part loads, assuring uninterrupted service in the event one of the two circuits fails. The number of compressors also ensures a precise multistep management of the cooling and heating capacity provided by each units. VShaped coil geometry Open angle vshaped coils for achieving the maximum ef ciency a all conditions. A speci c design of the condensing modules allow to reduce the units footprint as well as the clearances, thus facilitating service and maintenance operations. The structure is also designed to allow the easiest access to all the components in order to simplify maintenance work. Heat Pumps at 12 C outdoor temperature NECSQ models host several cuttingedge implementations, focused on the ef ciency and extended operation in winter mode, also with harsh outdoor conditions. Heat pumps can in fact be equipped with the LT low temperature option. This includes speci c regulation which activates adequate refrigerant injection, allowing to achieve 10 C for the SL versions and 12 C the CA versions. Silent Versions Combined with the Class A versions, the sound power level is also a distinctive feature on the new NECS range. The new SL III NECSQ_1314_3218_201005_GB HFC R410A

4 2. UNIT DESCRIPTION NECSQ INTEGRA unit for 4pipe systems, air source for outdoor installation Multipurpose outdoor unit for use in 4pipe systems for the simultaneous production of chilled and hot water by means of two independent hydronic circuits. These units are able to satisfy the demand for hot and cold water simultaneously through a system that does not require seasonal switching and is therefore a valid alternative to traditional plants with chiller and boiler. This unit is equipped with hermetic rotary Scroll compressors, with R410A, axial fans, shell and tube heat exchangers and electronic expansion valve. The range is composed by units equipped with four, six and eight compressors in multicircuit configuration. 2.1 Standard unit layout Structure Structure specifically designed for outdoor installation. Basement and frame in hotgalvanised shaped sheet steel with a suitable thickness. All parts polyesterpowder painted to assure total weather resistance. Refrigerant circuit Main components of the cooling circuit: two to four circuits with tandem compressors for each circuit R410A refrigerant multicircuit shell and tubes heat exchangers antifreeze heaters on both heat exchangers liquid line check valve dehydrator filter coolant line sight glass with humidity indicator electronic thermostatic valves liquid receivers high and low pressure transducers high and low pressure gauges high pressure safety valve low pressure safety valve high pressure safety switches crankcase heater on each compressor 4way reverse cycle valves Compressor Rotary hermetic scroll compressors in tandem layout complete with oil sump heater, electronic overheating protection with centralised manual reset and a twopole electric motor. Plant (side) heating exchanger water Direct expansion multicircuit shell and tube exchanger with asymmetric side coolant fl ows for maintaining the coolant at the correct speed inside the tubes when passing from the liquid to the gas phase. Steel shell with foamed closedcell elastomer anticondensation lining. The shell & tube is manufactured using copper tubes with internal grooves for favouring heat exchange and mechanically expanded onto the tube plates. An electric antifreeze heater prevents the ice from forming inside the exchanger when the unit is not working but connected to the electrical supply. When the unit is working, it is protected by a differential pressure switch mounted on the water side. Heat exchanger featuring two, three or four coolant circuits depending on the model. The hydronic group is composed by: differential pressure switch airvent valve discharge valve hydraulic connection flush with unit s enclosure Plant (side) cooling exchanger water Direct expansion multicircuit shell and tube exchanger with asymmetric side coolant flows for maintaining the coolant at the correct speed inside the tubes when passing from the gas to the liquid phase. Steel shell with foamed closedcell elastomer anticondensation lining. The shell & tube is manufactured using copper tubes with internal grooves for favouring heat exchange and mechanically expanded onto the tube plates. When the unit is working, it is protected by a differential pressure switch mounted on the water side. Heat exchanger featuring two, three or four coolant circuits depending on the model. The hydronic group is composed by: differential pressure switch airvent valve discharge valve hydraulic connection flush with unit s enclosure Source (side) heat exchanger air Finned coil exchanger made from copper tubes and aluminium fins. The aluminium fins are correctly spaced to guarantee optimum heat exchange efficiency. The differentiated circulation suitably distributes the liquid in the coil during the expansion phase. Coil with a sidewaysv layout and diaphragm separating the fan chamber to ensure that the adjacent circuits are independently ventilated. Electrical panel Electric power and control panel, built to EN /EC 2041 standards, complete with: control circuit transformer, general door lock isolator, fuses and contactors for compressors and fans, auxiliary 4..20mA analogue input, terminals for cumulative alarm block (BCA), remote ON/OFF terminals, relays for remote pump(s) activation for both circuits (only for units without hydronic pumps), springtype control circuit terminal board, electric panel for outdoor installation, electrical board for outdoor installation, electronic controller, multilanguage user keypad with LCD display, IP54 protection. Power input: 400V~ ±10% 50Hz 3N. Fan section Doubleasymmetrical and independent ventilation system composed by 450mm and 800 axial electric fans, protected to IP54, with external rotor and plasticcoated aluminium blades. Housed in aerodynamic hoods complete with safety grille. 6 pole electric motor with builtin overload protection. Differentiated ventilation control disabling the fan section of inactive circuits. Condensation control with continuous adjustment of fan rotation speed. 2.2 Certification, reference standard The unit complies with the following directives and relative amendments: Machinery Directive: 2006/42/EC. E.C.D. 89/336/EEC /108/EC. Low Voltage Directive 2006/95/EC. Pressure Equipment Directive 97/23/EC. Mod. A1. TÜVItaly Tests Tests performed throughout the production process, as indicated in ISO9001. Performance or noise tests can be performed by highly qualified staff in the presence of customers. Performance tests comprise the measurement of: 1 NECSQ_1314_3218_201005_GB HFC R410A

5 UNIT DESCRIPTION NECSQ electrical data water ow rates working temperatures power input power output pressure drops on the waterside exchanger both at full load (at the conditions of selection and at the most critical conditions for the condenser) and at part load conditions. During performance testing it is also possible to simulate the main alarm states. Noise tests are performed to check noise emissions accordingto ISO Controller The W3000SE Large controller offers advanced functions and algorithms. The keypad features an easytouse interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multilevel menu, with selectable language setting. The regulation operates on both water circuits featuring the stepwise regulation referred to the return water temperature with proportional logic. This allows to satisfy simultaneously the different requests of both cooling and heating, with no need of mode setting. The diagnostics includes a complete alarm management, with the blackbox and alarm logging functions for enhanced analysis of the unit operation. For multiple units systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, BacnetoverIP, Echelon LonWorks. Compatibility with the remote keyboard managing up to 10 units. Availability of an internal real time clock for operation scheduling (4day pro les with 10 hour belts). The defrost adopts a proprietary selfadaptive logic, which features the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a bene t for the overall energy ef ciency. 2.5 Versions Unless one of the speci c versions indicated below is expressly indicated, the unit is in the basic con guration. CA Class A Class A highef ciency version for heat pump operation according to Eurovent criteria. This con guration features an oversized condensing section. SLCA Super low noise, Class A of efficiency Super Lownoise version, Class A of ef ciency as per Eurovent. Acoustic insulation on the compressors box, on pipes and a low fans rotational speed gives the minimization of sound emission. 2 NECSQ_1314_3218_201005_GB HFC R410A

6 UNIT DESCRIPTION NECSQ 2.6 Accessories Cu/Cu condensing coils Airrefrigerant heat exchanger with copper ns and tubes. Recommended for applications in corrosive atmospheres. Condensing coils with epoxycoated ns Painted airrefrigerant heat exchanger. Recommended for applications in medium level pollution atmospheres. Condensing coils with Fin Guard Silver treatment Airrefrigerant heat exchanger with epoxidic treatment on coils and ns. Recommended for marine exposure conditions, with an high level of pollution or other aggressive atmospheres. Soft start Electronic device adopted to manage the inrush current. Break down of the inrush current as soon as the electrical motor is switch on, lower motor s mechanical wear, favourable sizing for the electrical system. Remote phasesequence control Relay for controlling the phasesequence of mains. Protects loads against faults due to incorrect connection of the electric line. Compressors on/off signal Auxiliary contacts providing a voltagefree signal. Allows remote signalling of compressor s activation or remote control of any auxiliary loads. ModBUS connectivity Interface module for ModBUS protocols. Allows integration with BMS operating with ModBUS protocol. BACnet connectivity Interface module for BACnet protocols. Allows integration with BMS operating with BACnet protocol. Echelon connectivity Interface module for Echelon systems. Allows integration with BMS operating with Echelon protocol. Compr. discharge line valve Shutoff solenoid valve on compressor discharge circuit. Simplifies maintenance activities. Automatic circuit breakers Overcurrent switch on the major electrical loads. It protects compressors and/or fans from possible current peaks. Input remote demand limit Digital input (voltage free). It permits to limit the unit s power absorption for safety reasons or in temporary situation. Antiintrusion grille Antiintrusion grille. Avoid the intrusion of solid bodies into the unit s structure. Numbered cables on electrical board BACnet OVER IP connectivity Interface module for BACnet OVERIP protocols. Allows to interconnect BACnet devices over Internet Protocol within widearea networks. LT kit for low temperature Extends the operating lints down to 10 C on SL versions and 12 C on CA versions. Allows unit operation in heating mode in strong winter conditions. Enclosure & ext.conn. Acoustic encolsure on both compressor and pump sections (when applicable), water connections ush with chiller enclosure. Noise emission reduction. Side panels on the coils Metallic panels on the coils (piping side only). Improve protection and unit s aesthetics. Reinforcing bars Bars used to reinforce the structure. Improve resistance during long transportation. HP and LP gauges High and low pressure gauges. Allows immediate reading of the pressure values on both low and high pressure circuits. Compressor suction valve Shutoff solenoid valve on compressor s suction circuit. Simplifies maintenance activities. 3 NECSQ_1314_3218_201005_GB HFC R410A

7 3. ELECTRONIC CONTROLLER NECSQ 3.1 CONTROL UNIT with LED display The W3000Large control unit with liquid crystal display (LCD) is tted on all the units. This keypad uses a user interface with a choice of seven European languages: Italian, English, French, German, Spanish, Swedish and Russian. This allows the control unit interface to be chosen to suit the country of destination or, thanks to English, to be completely independent for all geographical areas. This type of operator panel is also available as a remote keypad, to be connected to the unit by means of a serial connection up to a maximum distance of 200 metres without a power supply (in this case, power is supplied by the unit), or a maximum of 500 metres with a dedicated local power supply. It is possible to interface with commercially available BMS systems as it is compatible with the BACnet, BAC net OverIP, ModBUS and LonWorks protocols. The Black Box stores 200 alarm events; these can be printed with any kind of personal computer. The Internal Clock manages a weekly scheduler organised into time bands in order to optimise unit performance by minimising power consumption. Up to 10 daily time bands can be associated with different operating setpoints. As a result, power production is optimised during daily peaks of demand and minimised during periods of inactivity, such as during the night. If there is no demand for hot or chilled water, the clock can switch the unit off and switch it back on later. Heat adjustment is performed using algorithms based on proportional step control or on proportional/integral on the two probes at the inlet and outlet of the heat exchanger. There is also the QuickMind algorithm which was especially developed by Climaveneta to ensure the unit operates correctly even with systems featuring a low water content. QuickMind is a special control unit which monitors the main operating parameters, predicts system behaviour and anticipates unit settings in order to constantly optimise performance; it allows both return and delivery water temperatures to be chosen as adjustment parameters. It can reduce outlet temperature uctuations even with a small amount of water in the system. When, for dualcompressor chillers featuring a maximum of 12 startups per hour and using a traditional adjustment system, the minimum recommended water content is 5.5 l/kw, Quick Mind ensures the same chiller operates correctly even with a water content of just 2.5 l/kw and considerably reduces outlet temperature uctuations. The above graph shows that outlet temperature uctuations with QuickMind are limited to 4.3 C as opposed to 7.54 C if the traditional adjustment system were used, without even ensuring an acceptable minimum compressor start time. 4 NECSQ_1314_3218_201005_GB HFC R410A

8 ELECTRONIC CONTROLLER NECSQ Remote keyboard As an alternative to the standard keyboard, the NECS has a W3000 Compact operator panel with liquid crystal display. (LCD) This keyboard employs a user interface with 3 European languages that may be selected by the user, two of which are preset, and a further language of choice which may be French, German, Spanish, Swedish or Russian (to be speci ed on order). This allows the control unit interface to be chosen to suit the country of destination or, thanks to English, to be completely independent for all geographical areas. This same type of operator panel is also available as a remote keyboard, to be connected to the unit by means of a serial connection up to a maximum distance of 200 metres without power supply (in this case power is supplied by the unit), or a maximum of 500 metres with dedicated local power supply. 5 NECSQ_1314_3218_201005_GB HFC R410A

9 4.1 GENERAL TECHNICAL DATA NECSQ B SIZE NECSQ /B COOLING (1) Cooling capacity kw Total power input (unit) kw EER ESEER 2,81 2,89 2,75 2,77 2,82 2,89 2,89 Heat exchanger water flow m³/h 60,7 65,0 70,9 77,8 85,4 94,0 97,7 Heat exchanger pressure drop kpa 53,4 46,9 55,8 38,1 46,0 42,4 45,8 NECSQ /B HEATING (2) Heating capacity kw Total power input (unit) kw COP Heat exchanger water flow m³/h Heat exchanger pressure drop kpa NECSQ /B REFRIGERATION AND HEATING (3) Cooling capacity kw Total power input (unit) kw Heat exchanger water flow m³/h 60,7 65,0 70,9 77,8 85,4 94,0 97,7 Heat exchanger pressure drop kpa 53,4 46,9 55,8 38,1 46,0 42,4 45,8 Heat recovery thermal capacity kw TER Total Efficiency Ratio 7,55 7,66 7,64 7,55 7,62 7,67 7,64 Heat exchanger recovery water flow Plant side heat exchanger recovery pressure drop m³/h kpa COMPRESSORS Number N Number of capacity N Number of circuits N Type of regulation STEPS STEPS STEPS STEPS STEPS STEPS STEPS Minimum capacity steps % Type of refrigerant R410A R410A R410A R410A R410A R410A R410A Refrigerant charge kg Oil charge kg ,48 66,1 63,4 79,1 90, ,50 70,9 55,8 84,3 78, ,45 77,6 66,9 94,2 98, ,42 84,2 44, , ,49 91,7 52, , , , , , , ,8 FANS Number Air flow Singol power input N. m³/s kw ,0 34,6 34,6 39,5 53,1 51,1 51, NOISE LEVELS (4) Total sound power db(a) Total sound pressure db(a) DIMENSIONS AND WEIGHTS (5) Length mm. Width mm. Height mm. Weight kg Plant (side) cooling exchanger water (in/out) 12/7 C Source (side) heat exchanger air (in) 35 C 2 Plant (side) heating exchanger water (in/out) 40/45 C Source (side) heat exchanger air (in) 7 C R.H. 87% 3 Plant (side) cooling exchanger water (in/out) 12/7 C Source (side) heat exchanger air (in) 35 C Plant (side) heating exchanger water (in/out) 40/45 C Source (side) heat exchanger air (in) 7 C R.H. 87% 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for noncertified units Average sound pressure level, at 10 (m.) distance, unit in a free field on a reflective surface; nonbinding value obtained from the sound power level 5 Standard configuration Not available 6 ELCADOC Ver NECSQ_1314_3218_201005_EN R410A

10 GENERAL TECHNICAL DATA NECSQ B SIZE NECSQ /B COOLING (1) Cooling capacity kw Total power input (unit) kw EER ESEER 2,74 2,82 2,81 2,89 2,82 2,74 Heat exchanger water flow m³/h Heat exchanger pressure drop kpa 46,3 48,1 54,4 42,4 46,3 50,2 NECSQ /B HEATING (2) Heating capacity kw Total power input (unit) kw COP Heat exchanger water flow m³/h Heat exchanger pressure drop kpa NECSQ /B REFRIGERATION AND HEATING (3) Cooling capacity kw Total power input (unit) kw Heat exchanger water flow m³/h Heat exchanger pressure drop kpa 46,3 48,1 54,4 42,4 46,3 50,2 Heat recovery thermal capacity kw TER Total Efficiency Ratio 7,68 7,62 7,61 7,63 7,63 7,67 Heat exchanger recovery water flow Plant side heat exchanger recovery pressure drop m³/h kpa COMPRESSORS Number N Number of capacity N Number of circuits N Type of regulation STEPS STEPS STEPS STEPS STEPS STEPS Minimum capacity steps % Type of refrigerant R410A R410A R410A R410A R410A R410A Refrigerant charge kg Oil charge kg , , , , , , , , , , , , , , , , , ,8 FANS Number Air flow Singol power input N. m³/s kw ,9 70,8 71,9 69,2 69,2 69, NOISE LEVELS (4) Total sound power db(a) Total sound pressure db(a) DIMENSIONS AND WEIGHTS (5) Length mm. Width mm. Height mm. Weight kg Plant (side) cooling exchanger water (in/out) 12/7 C Source (side) heat exchanger air (in) 35 C 2 Plant (side) heating exchanger water (in/out) 40/45 C Source (side) heat exchanger air (in) 7 C R.H. 87% 3 Plant (side) cooling exchanger water (in/out) 12/7 C Source (side) heat exchanger air (in) 35 C Plant (side) heating exchanger water (in/out) 40/45 C Source (side) heat exchanger air (in) 7 C R.H. 87% 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for noncertified units Average sound pressure level, at 10 (m.) distance, unit in a free field on a reflective surface; nonbinding value obtained from the sound power level 5 Standard configuration Not available 7 ELCADOC Ver NECSQ_1314_3218_201005_EN R410A

11 GENERAL TECHNICAL DATA NECSQ CA SIZE NECSQ /CA COOLING (1) Cooling capacity kw Total power input (unit) kw EER ESEER 2,96 3,03 2,94 3,01 3,04 3,03 3,03 Heat exchanger water flow m³/h 62,4 66,6 73,2 81,1 90,2 96,3 100 Heat exchanger pressure drop kpa 56,4 49,2 59,4 41,5 51,3 44,5 48,1 NECSQ /CA HEATING (2) Heating capacity kw Total power input (unit) kw COP Heat exchanger water flow m³/h Heat exchanger pressure drop kpa NECSQ /CA REFRIGERATION AND HEATING (3) Cooling capacity kw Total power input (unit) kw Heat exchanger water flow m³/h 62,4 66,6 73,2 81,1 90,2 96,3 100 Heat exchanger pressure drop kpa 56,4 49,2 59,4 41,5 51,3 44,5 48,1 Heat recovery thermal capacity kw TER Total Efficiency Ratio 7,55 7,66 7,64 7,55 7,62 7,67 7,64 Heat exchanger recovery water flow Plant side heat exchanger recovery pressure drop m³/h kpa COMPRESSORS Number N Number of capacity N Number of circuits N Type of regulation STEPS STEPS STEPS STEPS STEPS STEPS STEPS Minimum capacity steps % Type of refrigerant R410A R410A R410A R410A R410A R410A R410A Refrigerant charge kg Oil charge kg ,59 68,5 68,0 79,1 90, ,58 73,0 59,1 84,3 78, ,55 80,3 71,5 94,2 98, ,55 88,1 48, , ,60 95,0 56, , , , , , , ,8 FANS Number Air flow Singol power input N. m³/s kw ,9 46,1 46,1 56,6 70,8 68,2 69, NOISE LEVELS (4) Total sound power db(a) Total sound pressure db(a) DIMENSIONS AND WEIGHTS (5) Length mm. Width mm. Height mm. Weight kg Plant (side) cooling exchanger water (in/out) 12/7 C Source (side) heat exchanger air (in) 35 C 2 Plant (side) heating exchanger water (in/out) 40/45 C Source (side) heat exchanger air (in) 7 C R.H. 87% 3 Plant (side) cooling exchanger water (in/out) 12/7 C Source (side) heat exchanger air (in) 35 C Plant (side) heating exchanger water (in/out) 40/45 C Source (side) heat exchanger air (in) 7 C R.H. 87% 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for noncertified units Average sound pressure level, at 10 (m.) distance, unit in a free field on a reflective surface; nonbinding value obtained from the sound power level 5 Standard configuration Not available 8 ELCADOC Ver NECSQ_1314_3218_201005_EN R410A

12 GENERAL TECHNICAL DATA NECSQ CA SIZE NECSQ /CA COOLING (1) Cooling capacity kw Total power input (unit) kw EER ESEER 2,94 2,95 2,96 3,03 2,99 2,94 Heat exchanger water flow m³/h Heat exchanger pressure drop kpa 49,3 50,7 57,4 44,5 48,9 53,5 NECSQ /CA HEATING (2) Heating capacity kw Total power input (unit) kw COP Heat exchanger water flow m³/h Heat exchanger pressure drop kpa NECSQ /CA REFRIGERATION AND HEATING (3) Cooling capacity kw Total power input (unit) kw Heat exchanger water flow m³/h Heat exchanger pressure drop kpa 49,3 50,7 57,4 44,5 48,9 53,5 Heat recovery thermal capacity kw TER Total Efficiency Ratio 7,68 7,62 7,61 7,63 7,63 7,67 Heat exchanger recovery water flow Plant side heat exchanger recovery pressure drop m³/h kpa COMPRESSORS Number N Number of capacity N Number of circuits N Type of regulation STEPS STEPS STEPS STEPS STEPS STEPS Minimum capacity steps % Type of refrigerant R410A R410A R410A R410A R410A R410A Refrigerant charge kg Oil charge kg , , , , , , , , , , , , , , , , , ,8 FANS Number Air flow Singol power input N. m³/s kw ,2 94,3 95,9 92,2 92,2 92, NOISE LEVELS (4) Total sound power db(a) Total sound pressure db(a) DIMENSIONS AND WEIGHTS (5) Length mm. Width mm. Height mm. Weight kg Plant (side) cooling exchanger water (in/out) 12/7 C Source (side) heat exchanger air (in) 35 C 2 Plant (side) heating exchanger water (in/out) 40/45 C Source (side) heat exchanger air (in) 7 C R.H. 87% 3 Plant (side) cooling exchanger water (in/out) 12/7 C Source (side) heat exchanger air (in) 35 C Plant (side) heating exchanger water (in/out) 40/45 C Source (side) heat exchanger air (in) 7 C R.H. 87% 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for noncertified units Average sound pressure level, at 10 (m.) distance, unit in a free field on a reflective surface; nonbinding value obtained from the sound power level 5 Standard configuration Not available 9 ELCADOC Ver NECSQ_1314_3218_201005_EN R410A

13 GENERAL TECHNICAL DATA NECSQ SLCA SIZE NECSQ /SLCA COOLING (1) Cooling capacity kw Total power input (unit) kw EER ESEER 2,56 2,61 2,60 2,54 2,52 2,59 2,61 Heat exchanger water flow m³/h 57,2 61,4 68,5 73,8 79,5 88,2 92,2 Heat exchanger pressure drop kpa 47,4 41,8 52,0 34,3 39,8 37,3 40,8 NECSQ /SLCA HEATING (2) Heating capacity kw Total power input (unit) kw COP Heat exchanger water flow m³/h Heat exchanger pressure drop kpa NECSQ /SLCA REFRIGERATION AND HEATING (3) Cooling capacity kw Total power input (unit) kw Heat exchanger water flow m³/h 57,2 61,4 68,5 73,8 79,5 88,2 92,2 Heat exchanger pressure drop kpa 47,4 41,8 52,0 34,3 39,8 37,3 40,8 Heat recovery thermal capacity kw TER Total Efficiency Ratio 7,55 7,66 7,64 7,55 7,62 7,67 7,64 Heat exchanger recovery water flow Plant side heat exchanger recovery pressure drop m³/h kpa COMPRESSORS Number N Number of capacity N Number of circuits N Type of regulation STEPS STEPS STEPS STEPS STEPS STEPS STEPS Minimum capacity steps % Type of refrigerant R410A R410A R410A R410A R410A R410A R410A Refrigerant charge kg Oil charge kg ,46 65,6 62,4 79,1 90, ,45 69,6 53,7 84,3 78, ,49 78,7 68,8 94,2 98, ,43 84,5 45, , ,42 91,3 52, , , , , , , ,8 FANS Number Air flow Singol power input N. m³/s kw ,3 30,3 29,5 35,1 33,2 42,9 45, NOISE LEVELS (4) Total sound power db(a) Total sound pressure db(a) DIMENSIONS AND WEIGHTS (5) Length mm. Width mm. Height mm. Weight kg Plant (side) cooling exchanger water (in/out) 12/7 C Source (side) heat exchanger air (in) 35 C 2 Plant (side) heating exchanger water (in/out) 40/45 C Source (side) heat exchanger air (in) 7 C R.H. 87% 3 Plant (side) cooling exchanger water (in/out) 12/7 C Source (side) heat exchanger air (in) 35 C Plant (side) heating exchanger water (in/out) 40/45 C Source (side) heat exchanger air (in) 7 C R.H. 87% 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for noncertified units Average sound pressure level, at 10 (m.) distance, unit in a free field on a reflective surface; nonbinding value obtained from the sound power level 5 Standard configuration Not available 10 ELCADOC Ver NECSQ_1314_3218_201005_EN R410A

14 GENERAL TECHNICAL DATA NECSQ SLCA SIZE NECSQ /SLCA COOLING (1) Cooling capacity kw Total power input (unit) kw EER ESEER 2,60 2,52 2,55 2,61 2,60 2,60 Heat exchanger water flow m³/h Heat exchanger pressure drop kpa 43,2 41,7 48,3 37,8 42,2 46,8 NECSQ /SLCA HEATING (2) Heating capacity kw Total power input (unit) kw COP Heat exchanger water flow m³/h Heat exchanger pressure drop kpa NECSQ /SLCA REFRIGERATION AND HEATING (3) Cooling capacity kw Total power input (unit) kw Heat exchanger water flow m³/h Heat exchanger pressure drop kpa 43,2 41,7 48,3 37,8 42,2 46,8 Heat recovery thermal capacity kw TER Total Efficiency Ratio 7,68 7,62 7,61 7,63 7,63 7,67 Heat exchanger recovery water flow Plant side heat exchanger recovery pressure drop m³/h kpa COMPRESSORS Number N Number of capacity N Number of circuits N Type of regulation STEPS STEPS STEPS STEPS STEPS STEPS Minimum capacity steps % Type of refrigerant R410A R410A R410A R410A R410A R410A Refrigerant charge kg Oil charge kg , , , , , , , , , , , , , , , , , ,8 FANS Number Air flow Singol power input N. m³/s kw ,2 44,2 54,6 60,7 63,2 59, NOISE LEVELS (4) Total sound power db(a) Total sound pressure db(a) DIMENSIONS AND WEIGHTS (5) Length mm. Width mm. Height mm. Weight kg Plant (side) cooling exchanger water (in/out) 12/7 C Source (side) heat exchanger air (in) 35 C 2 Plant (side) heating exchanger water (in/out) 40/45 C Source (side) heat exchanger air (in) 7 C R.H. 87% 3 Plant (side) cooling exchanger water (in/out) 12/7 C Source (side) heat exchanger air (in) 35 C Plant (side) heating exchanger water (in/out) 40/45 C Source (side) heat exchanger air (in) 7 C R.H. 87% 4 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for noncertified units Average sound pressure level, at 10 (m.) distance, unit in a free field on a reflective surface; nonbinding value obtained from the sound power level 5 Standard configuration Not available 11 ELCADOC Ver NECSQ_1314_3218_201005_EN R410A

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

41

42

43

44

45 5. OPERATING RANGE NECSQ/B HEAT PUMP NECSQ COOLING Plant (side) heating exchanger water [ C] Air Temperature [ C] Plant (side) heating exchanger water [ C] COOLING AND HEATING Air Temperature [ C] Plant (side) cooling exchanger water [ C] Plant (side) cooling exchanger water [ C] NECSQ_1314_3218_201005_GB HFC R410A

46 OPERATING RANGE NECSQ/CA HEAT PUMP NECSQ Plant (side) heating exchanger water [ C] Air Temperature [ C] COOLING Limits in standard confi guration Limits with LT kit for low air temperatures Air Temperature [ C] Plant (side) cooling exchanger water [ C] 15 COOLING AND HEATING Plant (side) heating exchanger water [ C] Plant (side) cooling exchanger water [ C] NECSQ_1314_3218_201005_GB HFC R410A

47 OPERATING RANGE NECSQ/SLCA HEAT PUMP NECSQ Plant (side) heating exchanger water [ C] Air Temperature [ C] COOLING Limits in standard confi guration Limits with LT kit for low air temperatures Air Temperature [ C] Plant (side) cooling exchanger water [ C] Operating limits in silentrunning mode Operating limits in nonsilentrunning mode. In these conditions, ventilation is automatically increased to assure correct unit operation. COOLING AND HEATING 4 15 Plant (side) heating exchanger water [ C] Plant (side) cooling exchanger water [ C] NECSQ_1314_3218_201005_GB HFC R410A

48 OPERATING RANGE NECSQ ETHYLENE GLYCOL MIXTURE Ethylene glycol and water mixtures, used as a heatconveying fl uid, cause changes in unit performance. For correct data, use the factors indicated in the following table. Freezing point ( C) Ethylene glycol percentage by weight 0 12% 20% 30% 35% 40% 45% 50% cpf 1 0,985 0,98 0,974 0,97 0,965 0,964 0,96 cq 1 1,02 1,04 1,075 1,11 1,14 1,17 1,2 cdp 1 1,07 1,11 1,18 1,22 1,24 1,27 1,3 cpf cooling power correction factor cq: fl ow correction factor cdp: pressure drop correction factor For data concerning other kind of antifreeze solutions (e.g. propylene glycol) please contact our Sales Department. FOULING FACTORS The indicated performance levels assume the tubes are clean (fouling factor =1). For different fouling values, adjust performance levels using the correction factors shown in the following table. Fouling factors Plant (side) cooling exchanger Plant (side) heating exchanger f1 fk1 fx1 f2 fk2 fx2 (m 2 C/W) 4,4 x ,99 1,03 1,03 (m 2 C/W) 0,86 x ,96 0,99 0,99 0,98 1,04 1,04 (m 2 C/W) 1,72 x ,93 0,98 0,98 0,95 1,06 1,06 f1 f2 f3: potential correction factors fk1 fk2 fk3: compressor power input correction factors fx1 fx2 fx3: total power input correction factors 45 NECSQ_1314_3218_201005_GB HFC R410A

49 6. HYDRAULIC DATA NECSQ 6.1 Water flow and pressure drop Water flow in the heat exchangers is given by: Q=Px0,86/Dt Q: water flow (m 3 /h) Dt: difference between inlet and outlet water temp. ( C) P: heat exchanger capacity (kw) Pressure drop is given by: Dp= K x Q 2 /1000 Q: water flow (m 3 /h) Dp: pressure drop (kpa) K: unit size ratio SIZE K Cold Exchanger User Side Q min m 3 /h Q max m 3 /h C.a. min m 3 K Heat Exchanger User Side Q min m 3 /h Q max m 3 /h K Exchanger User Side to Recovery NECSQ /B ,5 36,6 95,2 3,9 14,5 36,6 95,2 14,5 36,6 95,2 NECSQ /B ,1 39,1 95,8 4,17 11,1 39,1 95,8 11,1 39,1 95,8 NECSQ /B ,1 42,6 104,9 4,54 11,1 42,6 104,9 11,1 42,6 104,9 NECSQ /B ,3 46,7 130,3 4,98 6,3 46,7 130,3 6,3 46,7 130,3 NECSQ /B ,3 51,4 130,3 5,48 6,3 51,4 130,3 6,3 51,4 130,3 NECSQ /B ,8 56,3 138,3 6,01 4,8 56,3 138,3 4,8 56,3 138,3 NECSQ /B ,8 58, ,26 4,8 58, ,8 58,7 144 NECSQ /B ,1 63,9 157,7 6,81 4,1 63,9 157,7 4,1 63,9 157,7 NECSQ /B ,7 68,5 186,2 7,3 3,7 68,5 186,2 3,7 68,5 186,2 NECSQ /B ,7 72,9 186,2 7,77 3,7 72,9 186,2 3,7 72,9 186,2 NECSQ /B ,5 78, ,35 2,5 78, ,5 78,3 204 NECSQ /B ,5 81, ,73 2,5 81, ,5 81,8 204 NECSQ /B ,5 85,1 210,3 9,08 2,5 85,1 210,3 2,5 85,1 210,3 NECSQ /CA ,5 36,6 95,2 3,9 14,5 36,6 95,2 14,5 36,6 95,2 NECSQ /CA ,1 39,1 95,8 4,17 11,1 39,1 95,8 11,1 39,1 95,8 NECSQ /CA ,1 42,6 104,9 4,54 11,1 42,6 104,9 11,1 42,6 104,9 NECSQ /CA ,3 46,7 130,3 4,98 6,3 46,7 130,3 6,3 46,7 130,3 NECSQ /CA ,3 51,4 130,3 5,48 6,3 51,4 130,3 6,3 51,4 130,3 NECSQ /CA ,8 56,3 138,3 6,01 4,8 56,3 138,3 4,8 56,3 138,3 NECSQ /CA ,8 58, ,26 4,8 58, ,8 58,7 144 NECSQ /CA ,1 63,9 157,7 6,81 4,1 63,9 157,7 4,1 63,9 157,7 NECSQ /CA ,7 68,5 186,2 7,3 3,7 68,5 186,2 3,7 68,5 186,2 NECSQ /CA ,7 72,9 186,2 7,77 3,7 72,9 186,2 3,7 72,9 186,2 NECSQ /CA ,5 78, ,35 2,5 78, ,5 78,3 204 NECSQ /CA ,5 81, ,73 2,5 81, ,5 81,8 204 NECSQ /CA ,5 85,1 210,3 9,08 2,5 85,1 210,3 2,5 85,1 210,3 NECSQ /SLCA ,5 36,6 95,2 3,9 14,5 36,6 95,2 14,5 36,6 95,2 NECSQ /SLCA ,1 39,1 95,8 4,17 11,1 39,1 95,8 11,1 39,1 95,8 NECSQ /SLCA ,1 42,6 104,9 4,54 11,1 42,6 104,9 11,1 42,6 104,9 NECSQ /SLCA ,3 46,7 130,3 4,98 6,3 46,7 130,3 6,3 46,7 130,3 NECSQ /SLCA ,3 51,4 130,3 5,48 6,3 51,4 130,3 6,3 51,4 130,3 NECSQ /SLCA ,8 56,3 138,3 6,01 4,8 56,3 138,3 4,8 56,3 138,3 NECSQ /SLCA ,8 58, ,26 4,8 58, ,8 58,7 144 NECSQ /SLCA ,1 63,9 157,7 6,81 4,1 63,9 157,7 4,1 63,9 157,7 NECSQ /SLCA ,7 68,5 186,2 7,3 3,7 68,5 186,2 3,7 68,5 186,2 NECSQ /SLCA ,7 72,9 186,2 7,77 3,7 72,9 186,2 3,7 72,9 186,2 NECSQ /SLCA ,5 78, ,35 2,5 78, ,5 78,3 204 NECSQ /SLCA ,5 81, ,73 2,5 81, ,5 81,8 204 NECSQ /SLCA ,5 85,1 210,3 9,08 2,5 85,1 210,3 2,5 85,1 210,3 Q min: minimum water fl ow admitted to the heat exchanger. Q max: maximum water fl ow admitted to the heat exchanger. W.c. min: minimum water content admitted in the plant, using traditional control logic. Q min m 3 /h Q max m 3 /h 46 NECSQ_1314_3218_201005_GB HFC R410A

50 7. HYDRONIC GROUPS (Optional) NECSQ The units can be supplied with a hydronic group. This houses all the main hydraulic components, thereby optimising hydraulic and electric installation space, time and cost. The innovative QuickMind control fi tted to the units in the NECS system, has been designed to work on systems with a low water content, offering highly professional alternatives to the installation of systems featuring storage units. The integrated hydronic unit is composed of: Single or twin INLINE centrifuge pump. differential pressure switch on the exchanger drain taps air vent antifreeze heater for piping Available pump configurations: Hydronic kit with one INLINE 2pole lowhead pump Hydronic kit with one INLINE 2pole highhead pump Hydronic kit with INLINE 2pole lowhead twin pumps pump Hydronic kit with INLINE 2pole highhead twin pumps 2pole low head pump Centrifugal pumps with inline suction and delivery fl anges, in single and twin versions. Pump body in cast iron and impeller in AISI 316L stainless steel or castiron, entirely laser technology welded. Mechanical seal with components in ceramics, carbon and EPDM elastomers. Threephase electric motor protected to IP55, insulation class F, suitable for continuous service. 2pole highhead pump All versions of the hydronic unit can be supplied with a high head pump. In these cases, the pump features a twopole motor even in the silentrunning versions. Twin pump A second standby pump for high or low pressures is available on request. The pumps are automatically exchanged on the basis of a rotation programme and the standby pump cuts in automatically if the primary pump fails. GENERAL CHARACTERISTICS Waterside mechanical filter (optional) Yfi lter designed and built to capture the impurities in the hydraulic circuit. It is fi tted with a 0.9 mm stainless steel mesh cartridge which can be replaced without removing the valve body from the piping. Unit electrical panel The unit electrical panel is fi tted with fuses and a circuit breaker contactor. Special pumps For pumps with different confi gurations, please contact our sales department. Additional components The supply does not include the following accessories though these are recommended to ensure correct system operation: MA Pressure gauges upline and downline from the unit GF Flexible joints on piping RI Onoff valves T Outlet control thermometer 47 NECSQ_1314_3218_201005_GB HFC R410A

51 HYDRONIC GROUPS (Optional) NECSQ CONFIGURATION OF HYDRONIC UNIT WITH 1/2 INLINE PUMPS SF P RETURN FROM HYDRAULIC SYSTEM S1 P EV Pd S2 DISCHARGE TO HYDRAULIC SYSTEM SC SF P RETURN FROM HYDRAULIC SYSTEM S3 P CD Pd S4 DISCHARGE TO HYDRAULIC SYSTEM SC Components of the hydronic kit: EV Plant (side) cooling exchanger water CD Plant (side) heating exchanger water P Water pump Pd Water differential pressure switch SC Drain valve SF Purge valve S1 Exchanger water inlet probe S2 Exchanger water ounlet probe S3 Exchanger water inlet probe S4 Exchanger water ounlet probe 48 NECSQ_1314_3218_201005_GB HFC R410A

52 HYDRONIC GROUPS (Optional) NECSQ LOW HEAD SINGLE INLINE PUMP PLANT (SIDE) COOLING EXCHANGER WATER Pf (1) Q (1) Rif. N. poli F.L.I. F.L.A. Hp KP Dpu Hu [kw] [m3/h] Pump [kw] [A] [kpa] [kpa] [kpa] ,9 A FCE 80125/40 2 4,0 8, ,7 58, ,2 A FCE 80125/40 2 4,0 8, ,3 52, ,9 B FCE 80125/55 2 5,5 10, ,3 61, ,6 B FCE 80125/55 2 5,5 10, ,2 43, ,5 B FCE 80125/55 2 5,5 10, ,2 52, ,7 C FCE 80160/75 2 7,5 13, ,7 50, ,7 C FCE 80160/75 2 7,5 13, ,7 54, ,3 E FCE /75 4 7,5 15, , ,9 E FCE /75 4 7,5 15, ,2 54, ,3 D FCE / ,0 20, ,2 61, ,2 D FCE / ,0 20, , ,1 D FCE / ,0 20, , ,7 F FCS / ,0 22, ,3 130 (1) Values refer to rated operating conditions KP Coeffi cients for calculating pressure drops Pf Cooling capacity of unit Unit with hydronic unit without network fi lter Q Flow of water to evaporator Dpu Total pressure drop of hydronic group F.L.I. Power absorbed by pump Hu Working head F.L.A. Current absorbed by pump Hp Head of pump LOW HEAD SINGLE INLINE PUMP PLANT (SIDE) HEATING EXCHANGER WATER Pt (1) Q (1) Rif. N. poli F.L.I. F.L.A. Hp KP Dpu Hu [kw] [m3/h] Pump [kw] [A] [kpa] [kpa] [kpa] ,4 A FCE 80125/40 2 4,0 8, ,7 67, ,2 A FCE 80125/40 2 4,0 8, ,3 60, ,9 B FCE 80125/55 2 5,5 10, ,3 72, ,4 B FCE 80125/55 2 5,5 10, ,2 50, ,6 C FCE 80160/75 2 5,5 13, ,2 59, ,0 E FCE /75 4 7,5 15, ,7 58, ,3 E FCE /75 4 7,5 15, ,7 63, ,2 E FCE /75 4 7,5 15, , ,9 E FCE /75 4 7,5 15, ,2 61, ,9 D FCE / ,0 20, , ,4 F FCS / ,0 22, , ,1 F FCS / ,0 22, , ,6 F FCS / ,0 22, ,8 104 PUMP SPECIFICATIONS H [kpa] C D A B E F Q [m3/h] 49 NECSQ_1314_3218_201005_GB HFC R410A

53 HYDRONIC GROUPS (Optional) NECSQ LOW HEAD TWIN INLINE PUMP PLANT (SIDE) COOLING EXCHANGER WATER Pf (1) Q (1) Rif. N. poli F.L.I. F.L.A. Hp KP Dpu Hu [kw] [m3/h] Pump [kw] [A] [kpa] [kpa] [kpa] ,9 A FCTE 80125/40 2 4,0 8, ,7 58, ,2 A FCTE 80125/40 2 4,0 8, ,3 52, ,9 B FCTE 80125/55 2 5,5 10, ,3 61, ,6 B FCTE 80125/55 2 5,5 10, ,2 43, ,5 B FCTE 80125/55 2 5,5 10, ,2 52, ,7 C FCTE 80160/75 2 7,5 13, ,7 50, ,7 C FCTE 80160/75 2 7,5 13, ,7 54, ,3 E FCTE /75 4 7,5 15, , ,9 E FCTE /75 4 7,5 15, ,2 54, ,3 D FCTE / ,0 20, ,2 61, ,2 D FCTE / ,0 20, , ,1 D FCTE / ,0 20, , ,7 F FCTS / ,0 22, ,3 131 (1) Values refer to rated operating conditions KP Coeffi cients for calculating pressure drops Pf Cooling capacity of unit Unit with hydronic unit without network fi lter Q Flow of water to evaporator Dpu Total pressure drop of hydronic group F.L.I. Power absorbed by pump Hu Working head F.L.A. Current absorbed by pump Hp Head of pump LOW HEAD TWIN INLINE PUMP PLANT (SIDE) HEATING EXCHANGER WATER Pt (1) Q (1) Rif. N. poli F.L.I. F.L.A. Hp KP Dpu Hu [kw] [m3/h] Pump [kw] [A] [kpa] [kpa] [kpa] ,4 A FCTE 80125/40 2 4,0 8, ,7 67, ,2 A FCTE 80125/40 2 4,0 8, ,3 60, ,9 B FCTE 80125/55 2 5,5 10, ,3 72, ,4 B FCTE 80125/55 2 5,5 10, ,2 50, ,6 C FCTE 80160/75 2 5,5 13, ,2 59, ,0 E FCTE /75 4 7,5 15, ,7 58, ,3 E FCTE /75 4 7,5 15, ,7 63, ,2 E FCTE /75 4 7,5 15, , ,9 E FCTE /75 4 7,5 15, ,2 61, ,9 D FCTE / ,0 20, , ,4 F FCTS / ,0 22, , ,1 F FCTS / ,0 22, , ,6 F FCTS / ,0 22, ,8 105 PUMP SPECIFICATIONS H [kpa] B C D F 105 A E Q [m3/h] 50 NECSQ_1314_3218_201005_GB HFC R410A

54 HYDRONIC GROUPS (Optional) NECSQ HIGH HEAD 2 POLES SINGLE INLINE PUMP PLANT (SIDE) COOLING EXCHANGER WATER Pf (1) Q (1) Rif. N. poli F.L.I. F.L.A. Hp KP Dpu Hu [kw] [m3/h] Pump [kw] [A] [kpa] [kpa] [kpa] ,9 A FCE 80160/75 2 7,5 13, ,7 58, ,2 A FCE 80160/75 2 7,5 13, ,3 52, ,9 A FCE 80160/75 2 7,5 13, ,3 61, ,6 A FCE 80160/75 2 7,5 13, ,2 43, ,5 B FCE 80200/ ,0 20, ,2 52, ,7 B FCE 80200/ ,0 20, ,7 50, ,7 C FCE / ,0 20, ,7 54, ,3 C FCE / ,0 20, , ,9 C FCE / ,0 20, ,2 54, ,3 D FCE / ,5 32, ,2 61, ,2 D FCE / ,5 32, , ,1 D FCE / ,5 32, , ,7 D FCE / ,5 32, ,3 256 (1) Values refer to rated operating conditions KP Coeffi cients for calculating pressure drops Pf Cooling capacity of unit Unit with hydronic unit without network fi lter Q Flow of water to evaporator Dpu Total pressure drop of hydronic group F.L.I. Power absorbed by pump Hu Working head F.L.A. Current absorbed by pump Hp Head of pump HIGH HEAD 2 POLES SINGLE INLINE PUMP PLANT (SIDE) HEATING EXCHANGER WATER Pt (1) Q (1) Rif. N. poli F.L.I. F.L.A. Hp KP Dpu Hu [kw] [m3/h] Pump [kw] [A] [kpa] [kpa] [kpa] ,4 A FCE 80160/75 2 7,5 13, ,7 67, ,2 A FCE 80160/75 2 7,5 13, ,3 60, ,9 A FCE 80160/75 2 7,5 13, ,3 72, ,4 A FCE 80160/75 2 7,5 13, ,2 50, ,6 B FCE 80200/ ,0 20, ,2 59, ,0 B FCE 80200/ ,0 20, ,7 58, ,3 C FCE / ,0 20, ,7 63, ,2 C FCE / ,0 20, , ,9 C FCE / ,0 20, ,2 61, ,9 D FCE / ,5 32, , ,4 D FCE / ,5 32, , ,1 D FCE / ,5 32, , ,6 D FCE / ,5 32, ,8 228 PUMP SPECIFICATIONS H [kpa] D B C A Q [m3/h] 51 NECSQ_1314_3218_201005_GB HFC R410A

55 HYDRONIC GROUPS (Optional) NECSQ HIGH HEAD 2 POLES TWIN INLINE PUMP PLANT (SIDE) COOLING EXCHANGER WATER Pf (1) Q (1) Rif. N. poli F.L.I. F.L.A. Hp KP Dpu Hu [kw] [m3/h] Pump [kw] [A] [kpa] [kpa] [kpa] ,9 A FCTE 80160/75 2 7,5 13, ,7 58, ,2 A FCTE 80160/75 2 7,5 13, ,3 52, ,9 A FCTE 80160/75 2 7,5 13, ,3 61, ,6 A FCTE 80160/75 2 7,5 13, ,2 43, ,5 B FCTE 80200/ ,0 20, ,2 52, ,7 B FCTE 80200/ ,0 20, ,7 50, ,7 C FCTE / ,0 20, ,7 54, ,3 C FCTE / ,0 20, , ,9 C FCTE / ,0 20, ,2 54, ,3 D FCTE / ,5 32, ,2 61, ,2 D FCTE / ,5 32, , ,1 D FCTE / ,5 32, , ,7 D FCTE / ,5 32, ,3 248 (1) Values refer to rated operating conditions KP Coeffi cients for calculating pressure drops Pf Cooling capacity of unit Unit with hydronic unit without network fi lter Q Flow of water to evaporator Dpu Total pressure drop of hydronic group F.L.I. Power absorbed by pump Hu Working head F.L.A. Current absorbed by pump Hp Head of pump HIGH HEAD 2 POLES TWIN INLINE PUMP PLANT (SIDE) HEATING EXCHANGER WATER Pt (1) Q (1) Rif. N. poli F.L.I. F.L.A. Hp KP Dpu Hu [kw] [m3/h] Pump [kw] [A] [kpa] [kpa] [kpa] ,4 A FCTE 80160/75 2 7,5 13, ,7 67, ,2 A FCTE 80160/75 2 7,5 13, ,3 60, ,9 A FCTE 80160/75 2 7,5 13, ,3 72, ,4 A FCTE 80160/75 2 7,5 13, ,2 50, ,6 B FCTE 80200/ ,0 20, ,2 59, ,0 B FCTE 80200/ ,0 20, ,7 58, ,3 C FCTE / ,0 20, ,7 63, ,2 C FCTE / ,0 20, , ,9 C FCTE / ,0 20, ,2 61, ,9 D FCTE / ,5 32, , ,4 D FCTE / ,5 32, , ,1 D FCTE / ,5 32, , ,6 D FCTE / ,5 32, ,8 219 PUMP SPECIFICATIONS H [kpa] B D A C Q [m3/h] 52 NECSQ_1314_3218_201005_GB HFC R410A

56 8. ELECTRICAL DATA NECSQ/B NECSQ Maximum values Size n F.L.I. [kw] Compressor Fan motors (1) Total (1) (2) F.L.A. [A] L.R.A. [A] x35,8+1x46,5 3x58,9+1x73,6 3x310+1x ,8 165,9 273, x35,8+2x46,5 2x58,9+2x73,6 2x310+2x ,8 176,6 287, x46,5 4x73,6 4x , , x35,8+2x27,4 4x58,9+2x45,8 4x310+2x , , x35,8 6x58,9 6x ,8 232,8 387, x35,8+2x46,5 4x58,9+2x73,6 4x310+2x ,8 254, x35,8+3x46,5 3x58,9+3x73,6 3x310+3x ,8 264,9 431, x46,5 6x73,6 6x , , x35,8 8x58,9 8x ,8 310,4 516, x35,8+2x46,5 6x58,9+2x73,6 6x310+2x ,8 331,8 546, x35,8+4x46,5 4x58,9+4x73,6 4x310+4x ,8 353,2 575, x35,8+6x46,5 2x58,9+6x73,6 2x310+6x ,8 374, x46,5 8x73,6 8x , ,4 955 F.L.I. [kw] F.L.A. [A] F.L.I. [kw] F.L.A. [A] L.R.A. [A] F.L.I. Full load power input at max admissible condition F.L.A. Full load current at max admissible condition L.R.A. Locked rotor amperes for single compressor S.A. Starting current (1) Values calculated referring to the version with the maximum number of fans working at the max absorbed current (2) Safety values to be considered when cabling the unit for power supply and lineprotections Power supply: 400/3/50 Voltage tolerance: 10% Maximum voltage unbalance: 3% Give the typical operating conditions of units designed for outdoor installation, which can be associated (according to reference document IEC 60721) to the following classes: climatic conditions class 4K4H: air temperature range from 20 up to 55 C (*), relative humidity range from 4 up to 100%, with possible precipitations, at air pressure from 70 and 106 kpa and a maximum solar radiation of 1120 W/m2 special climatic conditions negligible biological conditions class 4B1 and 4C2: locations in a generic urban area mechanically active substances class 4S2: locations in areas with sand or dust representative of urban areas mechanical conditions class 4M1: locations protected from signifi cant vibrations or shocks. The required protection level for safe operation, according to reference document IEC 60529, is IP43XW (protection against access, to the most critical unit s parts, of external devices with diameter larger than 1 mm and rain). The unit can be considered IP44XW protected, i.e. protected against access of external devices (with diameter larger than 1 mm) and water in general. (*) for the unit s operating limits, see selection limits section. 53 NECSQ_1314_3218_201005_GB HFC R410A

57 ELECTRICAL DATA NECSQ/CA NECSQ Maximum values Size n F.L.I. [kw] Compressor Fan motors (1) Total (1) (2) F.L.A. [A] L.R.A. [A] x35,8+1x46,5 3x58,9+1x73,6 3x310+1x ,8 169,9 280, x35,8+2x46,5 2x58,9+2x73,6 2x310+2x ,8 180,6 295, x46,5 4x73,6 4x , , x35,8+2x27,4 4x58,9+2x45,8 4x310+2x , , x35,8 6x58,9 6x ,8 238, x35,8+2x46,5 4x58,9+2x73,6 4x310+2x ,8 260,2 428, x35,8+3x46,5 3x58,9+3x73,6 3x310+3x ,8 270,9 443, x46,5 6x73,6 6x , , x35,8 8x58,9 8x ,8 318, x35,8+2x46,5 6x58,9+2x73,6 6x310+2x ,8 339,8 561, x35,8+4x46,5 4x58,9+4x73,6 4x310+4x ,8 361,2 590, x35,8+6x46,5 2x58,9+6x73,6 2x310+6x ,8 382,6 620, x46,5 8x73,6 8x , ,6 970 F.L.I. [kw] F.L.A. [A] F.L.I. [kw] F.L.A. [A] L.R.A. [A] F.L.I. Full load power input at max admissible condition F.L.A. Full load current at max admissible condition L.R.A. Locked rotor amperes for single compressor S.A. Starting current (1) Values calculated referring to the version with the maximum number of fans working at the max absorbed current (2) Safety values to be considered when cabling the unit for power supply and lineprotections Power supply: 400/3/50 Voltage tolerance: 10% Maximum voltage unbalance: 3% Give the typical operating conditions of units designed for outdoor installation, which can be associated (according to reference document IEC 60721) to the following classes: climatic conditions class 4K4H: air temperature range from 20 up to 55 C (*), relative humidity range from 4 up to 100%, with possible precipitations, at air pressure from 70 and 106 kpa and a maximum solar radiation of 1120 W/m2 special climatic conditions negligible biological conditions class 4B1 and 4C2: locations in a generic urban area mechanically active substances class 4S2: locations in areas with sand or dust representative of urban areas mechanical conditions class 4M1: locations protected from signifi cant vibrations or shocks. The required protection level for safe operation, according to reference document IEC 60529, is IP43XW (protection against access, to the most critical unit s parts, of external devices with diameter larger than 1 mm and rain). The unit can be considered IP44XW protected, i.e. protected against access of external devices (with diameter larger than 1 mm) and water in general. (*) for the unit s operating limits, see selection limits section. 54 NECSQ_1314_3218_201005_GB HFC R410A

58 ELECTRICAL DATA NECSQ/SLCA NECSQ Maximum values Size n F.L.I. [kw] Compressor Fan motors (1) Total (1) (2) F.L.A. [A] L.R.A. [A] x35,8+1x46,5 3x58,9+1x73,6 3x310+1x394 1,2 2,2 162,3 265, x35,8+2x46,5 2x58,9+2x73,6 2x310+2x394 1,2 2,2 174,2 282, x46,5 4x73,6 4x394 1,2 2,2 195, x35,8+2x27,4 4x58,9+2x45,8 4x310+2x272 1, 2 2,2 208, x35,8 6x58,9 6x310 1, 2 2,2 225,6 373, x35,8+2x46,5 4x58,9+2x73,6 4x310+2x394 1, 2 2,2 249, x35,8+3x46,5 3x58,9+3x73,6 3x310+3x394 1, 2 2,2 261,3 423, x46,5 6x73,6 6x394 1, 2 2,2 293, x35,8 8x58,9 8x310 1, 2 2,2 300,8 497, x35,8+2x46,5 6x58,9+2x73,6 6x310+2x394 1, 2 2,2 324,6 531, x35,8+4x46,5 4x58,9+4x73,6 4x310+4x394 1, 2 2,2 348,4 565, x35,8+6x46,5 2x58,9+6x73,6 2x310+6x394 1, 2 2,2 369,8 594, x46,5 8x73,6 8x394 1, 2 2,2 391, F.L.I. [kw] F.L.A. [A] F.L.I. [kw] F.L.A. [A] L.R.A. [A] F.L.I. Full load power input at max admissible condition F.L.A. Full load current at max admissible condition L.R.A. Locked rotor amperes for single compressor S.A. Starting current (1) Values calculated referring to the version with the maximum number of fans working at the max absorbed current (2) Safety values to be considered when cabling the unit for power supply and lineprotections Power supply: 400/3/50 Voltage tolerance: 10% Maximum voltage unbalance: 3% Give the typical operating conditions of units designed for outdoor installation, which can be associated (according to reference document IEC 60721) to the following classes: climatic conditions class 4K4H: air temperature range from 20 up to 55 C (*), relative humidity range from 4 up to 100%, with possible precipitations, at air pressure from 70 and 106 kpa and a maximum solar radiation of 1120 W/m2 special climatic conditions negligible biological conditions class 4B1 and 4C2: locations in a generic urban area mechanically active substances class 4S2: locations in areas with sand or dust representative of urban areas mechanical conditions class 4M1: locations protected from signifi cant vibrations or shocks. The required protection level for safe operation, according to reference document IEC 60529, is IP43XW (protection against access, to the most critical unit s parts, of external devices with diameter larger than 1 mm and rain). The unit can be considered IP44XW protected, i.e. protected against access of external devices (with diameter larger than 1 mm) and water in general. (*) for the unit s operating limits, see selection limits section. 55 NECSQ_1314_3218_201005_GB HFC R410A

59 8.1 FULL LOAD SOUND LEVEL SOUND POWER NECSQ B SIZE Octave band [Hz] Total sound level Sound power level db(a) Working conditions Plant (side) cooling exchanger water (in/out) 12/7 C Source (side) heat exchanger air (in) 35 C Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for noncertified units Such certification refers specifically to the sound Power Level in db(a). This is therefore the only acoustic data to be considered as binding. SOUND PRESSURE LEVEL SIZE Octave band [Hz] at 10 m Total sound level Sound pressure level db(a) Working conditions Plant (side) cooling exchanger water (in/out) 12/7 C Source (side) heat exchanger air (in) 35 C Average sound pressure level, at 10 (m.) distance, unit in a free field on a reflective surface; nonbinding value obtained from the sound power level Additional soundproofing The sound power and pressure levels of /B version, are reduced of 2 db(a) when present the option "compressors and pumps acoustical enclosure". 56 ELCADOC Ver NECSQ_1314_3218_201005_EN Ref.: R410A

60 FULL LOAD SOUND LEVEL SOUND POWER NECSQ CA SIZE Octave band [Hz] Total sound level Sound power level db(a) Working conditions Plant (side) cooling exchanger water (in/out) 12/7 C Source (side) heat exchanger air (in) 35 C Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for noncertified units Such certification refers specifically to the sound Power Level in db(a). This is therefore the only acoustic data to be considered as binding. SOUND PRESSURE LEVEL SIZE Octave band [Hz] at 10 m Total sound level Sound pressure level db(a) Working conditions Plant (side) cooling exchanger water (in/out) 12/7 C Source (side) heat exchanger air (in) 35 C Average sound pressure level, at 10 (m.) distance, unit in a free field on a reflective surface; nonbinding value obtained from the sound power level Additional soundproofing The sound power and pressure levels of /CA version, are reduced of 2 db(a) when present the option "compressors and pumps acoustical enclosure". 57 ELCADOC Ver NECSQ_1314_3218_201005_EN Ref.: R410A

61 FULL LOAD SOUND LEVEL SOUND POWER NECSQ SLCA SIZE Octave band [Hz] Total sound level Sound power level db(a) Working conditions Plant (side) cooling exchanger water (in/out) 12/7 C Source (side) heat exchanger air (in) 35 C Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for noncertified units Such certification refers specifically to the sound Power Level in db(a). This is therefore the only acoustic data to be considered as binding. SOUND PRESSURE LEVEL SIZE Octave band [Hz] at 10 m Total sound level Sound pressure level db(a) Working conditions Plant (side) cooling exchanger water (in/out) 12/7 C Source (side) heat exchanger air (in) 35 C Average sound pressure level, at 10 (m.) distance, unit in a free field on a reflective surface; nonbinding value obtained from the sound power level 58 ELCADOC Ver NECSQ_1314_3218_201005_EN Ref.: R410A

62 10. DIMENSIONAL DRAWINGS NECSQ LIFTING SUPPORTING BASEMENT REMARKS: For installation purposes, please refer to the documentation sent after the purchasecontract. 5 B A This technical data should be considered as indicative. CLIMAVENETA may modify them at any moment. 5 H R1 R2 EVAPORATOR/RECUPERATOR SIDE EVAPORATOR/RECUPERATOR R4 R EVAPORATOR WATER INLET 2 EVAPORATOR WATER OUTLET AIR INLET 3 RECUPERATOR WATER INLET AIR OUTLET 4 RECUPERATOR WATER OUTLET 5 POWER INLET A1 NECSQ_1314_3218_201005_GB HFC R410A

63 DIMENSIONAL DRAWINGS NECSQ DIMENSIONS AND WEIGHTS CLEARANCE COLD EXCHANGER USER SIDE HEAT EXCHANGER USER SIDE USER SIDE EXCHANGER TO RECOVERY SIZE A B H PESO R1 R2 R3 R4 in/out in/out in/out [mm] [mm] [mm] [kg] [mm] [mm] [mm] [mm] TIPO Ø TIPO Ø TIPO Ø 1314 /B VICTAULIC 4" VICTAULIC 4" VICTAULIC 4" 1414 /B VICTAULIC 4" VICTAULIC 4" VICTAULIC 4" 1614 /B VICTAULIC 4" VICTAULIC 4" VICTAULIC 4" 1716 /B VICTAULIC 5" VICTAULIC 5" VICTAULIC 5" 1816 /B VICTAULIC 5" VICTAULIC 5" VICTAULIC 5" 2016 /B VICTAULIC 5" VICTAULIC 5" VICTAULIC 5" 2116 /B VICTAULIC 5" VICTAULIC 5" VICTAULIC 5" 2416 /B VICTAULIC 5" VICTAULIC 5" VICTAULIC 5" 2418 /B VICTAULIC 6" VICTAULIC 6" VICTAULIC 6" 2618 /B VICTAULIC 6" VICTAULIC 6" VICTAULIC 6" 2818 /B VICTAULIC 6" VICTAULIC 6" VICTAULIC 6" 3018 /B VICTAULIC 6" VICTAULIC 6" VICTAULIC 6" 3218 /B VICTAULIC 6" VICTAULIC 6" VICTAULIC 6" 1314 /CA VICTAULIC 4" VICTAULIC 4" VICTAULIC 4" 1414 /CA VICTAULIC 4" VICTAULIC 4" VICTAULIC 4" 1614 /CA VICTAULIC 4" VICTAULIC 4" VICTAULIC 4" 1716 /CA VICTAULIC 5" VICTAULIC 5" VICTAULIC 5" 1816 /CA VICTAULIC 5" VICTAULIC 5" VICTAULIC 5" 2016 /CA VICTAULIC 5" VICTAULIC 5" VICTAULIC 5" 2116 /CA VICTAULIC 5" VICTAULIC 5" VICTAULIC 5" 2416 /CA VICTAULIC 5" VICTAULIC 5" VICTAULIC 5" 2418 /CA VICTAULIC 6" VICTAULIC 6" VICTAULIC 6" 2618 /CA VICTAULIC 6" VICTAULIC 6" VICTAULIC 6" 2818 /CA VICTAULIC 6" VICTAULIC 6" VICTAULIC 6" 3018 /CA VICTAULIC 6" VICTAULIC 6" VICTAULIC 6" 3218 /CA VICTAULIC 6" VICTAULIC 6" VICTAULIC 6" 1314 /SLCA VICTAULIC 4" VICTAULIC 4" VICTAULIC 4" 1414 /SLCA VICTAULIC 4" VICTAULIC 4" VICTAULIC 4" 1614 /SLCA VICTAULIC 4" VICTAULIC 4" VICTAULIC 4" 1716 /SLCA VICTAULIC 5" VICTAULIC 5" VICTAULIC 5" 1816 /SLCA VICTAULIC 5" VICTAULIC 5" VICTAULIC 5" 2016 /SLCA VICTAULIC 5" VICTAULIC 5" VICTAULIC 5" 2116 /SLCA VICTAULIC 5" VICTAULIC 5" VICTAULIC 5" 2416 /SLCA VICTAULIC 5" VICTAULIC 5" VICTAULIC 5" 2418 /SLCA VICTAULIC 6" VICTAULIC 6" VICTAULIC 6" 2618 /SLCA VICTAULIC 6" VICTAULIC 6" VICTAULIC 6" 2818 /SLCA VICTAULIC 6" VICTAULIC 6" VICTAULIC 6" 3018 /SLCA VICTAULIC 6" VICTAULIC 6" VICTAULIC 6" 3218 /SLCA VICTAULIC 6" VICTAULIC 6" VICTAULIC 6" A2 NECSQ_1314_3218_201005_GB HFC R410A

64 11. KEY TO HYDRAULIC CONNECTIONS NECSQ UNI ISO 228/1 UNI ISO 7/1 Pipe threads where pressuretight joints are not made on the threads Designation, dimensions and tolerances. Used terminology: G: Pipe threads where pressuretight joints are not made on the threads A: Close tolerance class for external pipe threads where pressuretight joints are not made on the threads B: Wider tolerance class for external pipe threads where pressuretight joints are not made on the threads Internal threads: G letter followed by thread mark (only tolerance class) External threads: G letter followed by thread mark and by A letter for A class external threads or by B letter for B class external threads. Pipe threads where pressuretight joints are made on the threads Designation, dimensions and tolerances. Used terminology: Rp: Internal cylindrical threads where pressuretight joints are made on the threads Rc: Internal conical threads where pressuretight joints are made on the threads R: External conical threads where pressuretight joints are made on the threads Internal cylindrical threads: R letter followed by p letter Internal conical threads: R letter followed by c letter External conical threads: R letter Designation UNI ISO 7/1 Rp 1 1/2 UNI ISO 7/1 Rp 2 1/2 UNI ISO 7/1 Rp 3 UNI ISO 7/1 R 3 UNI ISO 228/1 G 4 B DN 80 PN 16 Description Internal cylindrical threads where pressuretight joints are made on the threads, defined by standard UNI ISO 7/1 Conventional ø 1 1/2 Internal cylindrical threads where pressuretight joints are made on the threads, defined by standard UNI ISO 7/1 Conventional ø 2 1/2 Internal cylindrical threads where pressuretight joints are made on the threads, defined by standard UNI ISO 7/1 Conventional ø 3 External conical threads where pressuretight joints are made on the threads, defined by standard UNI ISO 7/1 Conventional ø 3 Internal cylindrical threads where pressuretight joints are not made on the threads, defined by standard UNI ISO 228/1 Tolerance class B for external thread Conventional ø 4 Flange Nominal Diameter: 80 mm th. Nominal Pressure: 16 bar Notes: Conventional diameter value [in inches] identifies short thread designation, based upon the relative standard. All relative values are defi ned by standards. As example, here below some values: UNI ISO 7/1 UNI ISO 228/1 Conventional ø 1 1 Pitch mm mm External ø mm mm Core ø mm mm Thread height mm mm A3 NECSQ_1314_3218_201005_GB HFC R410A

65 Basel Zürich Uzwil Topqualität mit Spitzenservice Solothurn Kriens Buchs Münsingen Fribourg Lausanne Hauptsitz Niederlassung Geschäftsstellen Grüezi, ich bin einer der über 40 Servicetechniker der CTA. Servicestellen So sind sie, die «Botschafter» der CTA: freundlich und kompetent. Immer da, wenn Sie sie brauchen. 24 Stunden, rund um die Uhr. Mit Servicestellen und über 40 Fahrzeugen in der ganzen Schweiz. Ein gutes Gefühl für die Kunden und für die Installateure, die sich in jedem Fall auf Unterstützung, Service und Support verlassen können. Zu den Stärken in Planung, Produktion und Montage kommen die Stärken in Service und Dienstleistungen, in Lagerhaltung und Logistik, in Aus und Weiterbildung. Sie sind es, die die CTA zu einem zuverlässigen Partner machen. Aber CTA geht noch weiter: Mit wertvollen Zusatzleistungen wie zum Beispiel dem Support im Bereich der ChemRRV oder dem auf 12 Jahre angelegten Schutz und Sicherheitsprogramm CTAplus für Wärmepumpen. Bern CTA AG Hunzikenstrasse 2 CH3110 Münsingen Telefon +41 (0) Fax +41 (0) Zürich CTA AG Albisriederstrasse 232 CH8047 Zürich Telefon +41 (0) Fax +41 (0) Lausanne CTA AG En Budron B2 CH1052 Le Mont s/lausanne Telefon +41 (0) Fax +41 (0) /dt Technische Änderungen vorbehalten Freiburg CTA AG Route André Piller 20 CH1762 Givisiez Telefon +41 (0) Fax +41 (0) Solothurn CTA AG Bernstrasse 1 CH4573 LohnAmmannsegg Telefon +41 (0) Fax +41 (0) Basel CTA AG Grabenackerstrasse 15 CH4142 Münchenstein Telefon +41 (0) Fax +41 (0) Certified System I S O Certified System I S O Kriens CTA AG Grabenhofstrasse 6 CH6010 Kriens Telefon +41 (0) Fax +41 (0) Uzwil CTA AG Bahnhofstrasse 111 CH9240 Uzwil Telefon +41 (0) Fax +41 (0) Buchs CTA AG Langäulistrasse 35 CH9470 Buchs Telefon +41 (0) Fax +41 (0) info@cta.ch

NECS-N. Climaveneta Technical Bulletin. Reversible unit, air source for outdoor installation. 0202T T kw

NECS-N. Climaveneta Technical Bulletin. Reversible unit, air source for outdoor installation. 0202T T kw Climaveneta Technical Bulletin NECS_N_0202T_0612T_201007_GB r HFC R-410A 0202T - 0612T 53-159 kw Reversible unit, air source for outdoor installation (The photo of the unit is indicative and may change

More information

NECS-N. Climaveneta Technical Bulletin. Reversible unit, air source for outdoor installation. 0202T T kw

NECS-N. Climaveneta Technical Bulletin. Reversible unit, air source for outdoor installation. 0202T T kw Climaveneta Technical Bulletin NECS_N_0202T_0612T_201211_EN r HFC R-410A 0202T - 0612T 53-159 kw Reversible unit, air source for outdoor installation (The photo of the unit is indicative and may change

More information

NECS-ME. Climaveneta Technical Bulletin NECS_ME_0152_1604_201004_GB. Condenserless chiller ,5-432 kw

NECS-ME. Climaveneta Technical Bulletin NECS_ME_0152_1604_201004_GB. Condenserless chiller ,5-432 kw Climaveneta Technical Bulletin NECS_ME_0152_1604_201004_GB r HFC R-410A 0152-1604 39,5-432 kw Condenserless chiller (The photo of the unit is indicative and may change depending on the model) Refrigerant

More information

NECS. Climaveneta Technical Bulletin. Air-cooled water chillers with axial fans. 0202T T kw

NECS. Climaveneta Technical Bulletin. Air-cooled water chillers with axial fans. 0202T T kw Climaveneta Technical Bulletin _0202T_0612T_200912_GB r HFC R-410A 0202T - 0612T 53-159 kw Air-cooled water chillers with axial fans (The photo of the unit is indicative and may change depending on the

More information

NECS-W. Climaveneta Technical Bulletin. Water-cooled liquid chillers and water-to-water heat pumps kw

NECS-W. Climaveneta Technical Bulletin. Water-cooled liquid chillers and water-to-water heat pumps kw Climaveneta Technical Bulletin _0604_1204_201211_EN r HFC R-410A 0604-1204 174-371 kw Water-cooled liquid chillers and water-to-water heat pumps (The photo of the unit is indicative and may change depending

More information

BRH. Climaveneta Technical Bulletin. Water-cooled liquid chillers ,5-35,1 kw. Versatile High efficiency Maximum silent-running

BRH. Climaveneta Technical Bulletin. Water-cooled liquid chillers ,5-35,1 kw. Versatile High efficiency Maximum silent-running Climaveneta Technical Bulletin BRH_0011_0121_201211_EN BRH r HFC R-410A 0011-0121 5,5-35,1 kw Water-cooled liquid chillers (The photo of the unit is indicative and may change depending on the model) Versatile

More information

FOCS. Climaveneta Technical Bulletin FOCS_0751_1301_200909_GB. Air-cooled water chiller with helical fans kw

FOCS. Climaveneta Technical Bulletin FOCS_0751_1301_200909_GB. Air-cooled water chiller with helical fans kw Climaveneta Technical Bulletin _0751_1301_200909_GB 0751-1301 145-516 kw Air-cooled water chiller with helical fans (The photo of the unit is indicative and may change depending on the model) Flexibility

More information

NECS-W. Climaveneta Technical Bulletin NECS_W 0152_0612_200907_GB. Water-cooled liquid chillers and water-to-water heat pumps ,4-186 kw

NECS-W. Climaveneta Technical Bulletin NECS_W 0152_0612_200907_GB. Water-cooled liquid chillers and water-to-water heat pumps ,4-186 kw Climaveneta Technical Bulletin NECS_W 0152_0612_200907_GB r HFC R-410A 0152-0612 43,4-186 kw Water-cooled liquid chillers and water-to-water heat pumps (The photo of the unit is indicative and may change

More information

BRAN. Climaveneta Technical Bulletin BRAN_0011_0121_201211_EN ,6-31,3 kw. Reversible unit, air source for outdoor installation

BRAN. Climaveneta Technical Bulletin BRAN_0011_0121_201211_EN ,6-31,3 kw. Reversible unit, air source for outdoor installation Climaveneta Technical Bulletin BRAN_0011_0121_201211_EN BRAN r HFC R-410A 0011-0121 4,6-31,3 kw Reversible unit, air source for outdoor installation (The photo of the unit is indicative and may change

More information

NECS-ST. Climaveneta Technical Bulletin NECS_ST_0504_1204_200907_GB. Air-cooled water chiller with helical fans kw

NECS-ST. Climaveneta Technical Bulletin NECS_ST_0504_1204_200907_GB. Air-cooled water chiller with helical fans kw Climaveneta Technical Bulletin NECS_ST_0504_1204_200907_GB NECS-ST r HFC R-410A 0504-1204 104-341 kw Air-cooled water chiller with helical fans (The photo of the unit is indicative and may change depending

More information

NX-N. Climaveneta Technical Bulletin NX_N_0604T_1204T_201211_EN

NX-N. Climaveneta Technical Bulletin NX_N_0604T_1204T_201211_EN Climaveneta Technical Bulletin _201211_EN 060T - 120T 160 319 kw Reversible unit, air source for outdoor installation (unit with shell and tubes exchanger) (The photo of the unit is purely indicative and

More information

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING

More information

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual u Air Cooled Screw Chillers SLS 1202 to 4004 With or without total heat recovery 262 to 916 kw Engineering Data Manual EDM SLS407-A.4GB Date : December 2008 Supersedes : TM SLS407-A.3GB/11.06 Specifications

More information

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017 Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air

More information

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points Epsilon Echos+ 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Configuration /LN: Low noise unit /HP: Reversible heat pump /LE /HP: Reversible condensing unit Unique

More information

kw COOLING kw HEATING

kw COOLING kw HEATING Heat pump water/water liquid chillers for indoor installation. Inversion on hydraulic circuit. 394 1505 kw COOLING 477 1976 kw HEATING technicalcatalogue T_FRGSCRWP_0913_GB INDEX GENERAL CHARACTERISTICS...

More information

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS Energy saving thanks to a total recovery p Cooling Heating/DHW h Galletti multi-purpose heat pumps are total recovery units used for a simultaneous hot and

More information

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw Multifunction chillers for indoor installation. Cooling Capacity: 22 222 Heating Capacity: 25 236 Scroll compressors EC Plug Fans Plate type heat exchangers EER up to 3,12 COP up to 3,84 ESEER up to 4,01

More information

Air-to-water scroll chillers

Air-to-water scroll chillers Air-to-water scroll chillers Model CGA 040 to 115 Cooling capacity: 14-40 kw CG-PRC031B-GB Table of Contents Technical specifications...4 Standard configuration... 4 Hydraulic version... 4 Casing... 4

More information

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS RAE 1352 F.K + MV AIR R-407C FC Series RAE... F.K Cooling capacity from 77 to 289 kw - 2 circuits The air cooled chillers of RAE... F.K series, are designed for outdoor installation and are particularly

More information

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N E S A RE F R E IG RA N T G TECHNICAL MANUAL -FRIEND Y CONDENSING UNITS FOR OUTDOOR INSTALLATION O L CMA C 2 The manufacturer declines all the responsabilities regarding inaccuracies contained in this manual,

More information

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES Air to water chillers and heat pumps The water chillers range is an efficient and low-noise product designed for medium to big applications. The water chillers are suitable for water outlet temperatures

More information

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Quality Management Systems 0RB 008-05 Nominal cooling capacity 8- The new generation of Aquasnap liquid chillers was designed

More information

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB Packaged air cooled liquid chillers for outdoor installation 42 574 kw technicalcatalogue T_EGL_1012_GB INDEX EUROVENT CERTIFICATION... 3 GENERAL CHARACTERISTICS... 3 SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION...

More information

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw SPECIFICATION GUIDE NEOSYS Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw Air-to-water Heat Pump for outdoor installation (NAH) Nominal cooling capacity:

More information

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps. Air/water cooled chillers and heat pumps 41 303 kw General BETA ECHOS is a range of chillers and ductable air-water heat pumps. Configurations HP: Reversible heat pump LE: For connection to remote evaporator

More information

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient PRODUCT SELECTION DATA Easy and fast installation Compact, reliable and efficient Class A variable speed circulator available Air-Cooled Liquid Chillers 0RB 008-015 CARRIER participates in the ECP programme

More information

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years

More information

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes). Guide Specifications PART 1 GENERAL 1.01 SYSTEM DESCRIPTION Microprocessor controlled, air-cooled liquid chiller utilizing scroll compressors, low sound fans, hydronic pump system and optional fluid storage

More information

KELVIN Clim F497. Kelvin air conditioning

KELVIN Clim F497. Kelvin air conditioning KELVIN Clim F497 Cooling Capacity: 400 ~ 1260 kw Free-Cooling Capacity: 497 ~ 1492 kw Packaged air cooled liquid chillers with free-cooling system in A class energy efficiency for outdoor installation,

More information

FX-FC _201302_EN

FX-FC _201302_EN Climaveneta Technical Brochures FX-FC 1502-6002_201302_EN ELCA_Engine ver.1.4.0.19 FX-FC 1502-6002 332-1412 kw Chiller, air source with free-cooling (The photo of the unit is indicative and may vary depending

More information

Galletti Water chillers and heat pumps catalogue

Galletti   Water chillers and heat pumps catalogue Galletti www.galletti.it Water chillers and heat pumps catalogue Table of Contents/SMALL SYSTEMS MPI DC Water chillers and heat pumps with inverter compressor 6 models page 6 MCE MPE Air condensed water

More information

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw AIR-COOLED LIQUID CHILLER REVERSIBLE AIR-TO-WATER HEAT PUMP PRO-DIALOG PLUS 30RB/RQ 039S-60S Refrigerant HFC-40A Nominal cooling capacity 40-58 kw Nominal heating capacity 4-59 kw The new generation of

More information

ELFOEnergy Extended Inverter

ELFOEnergy Extended Inverter Technical Bulletin BT14F009GB-03 ELFOEnergy Extended Inverter AIR-COOLED INVERTER CHILLER FOR OUTDOOR INSTALLATION WSAT-XIN 21-171 RANGE PREMIUM Version Nominal cooling capacity (A35/W7) from 4 to 30 kw

More information

ELFOEnergy Duct Inverter

ELFOEnergy Duct Inverter Technical Bulletin BT14E002GB-02(EC1) ELFOEnergy Duct Inverter Air-water ductable liquid chiller for indoor or outdoor installation SERIES WSA-XIN 21-141 Nominal cooling capacity (A35/W7) da 4 a 31 kw

More information

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98 Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw Scroll Compressors Series: SCAEY-FC Leaflet: DE 98 Issue: 01/16 Supersedes: 12/13 Identification code Index Index... pag. 2 Identification code...»

More information

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the

More information

ERACS.C-N Higher efficiency air-cooled screw pump

ERACS.C-N Higher efficiency air-cooled screw pump ELITE TM Series COOLING ERACS.C-N Higher efficiency air-cooled screw pump HEATING HOT WATER Cooling Capacity:5~1341 (7~381 Tons) Heating Capacity:60~1363 (74~388 Tons) High Efficiency Air-cooled Heat Pump

More information

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES COOLING CAPACITY FROM 76 TO 612 Kw 1 AND 2 COOLING CIRCUITS RAE 1702 F Kc + P2 28 Above picture is only indicative

More information

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER

More information

HYDRONIC RESIDENTIAL

HYDRONIC RESIDENTIAL HYDRONIC RESIDENTIAL Chillers, reversible heat pumps and modular units for small and medium applications. Climaveneta. brand of Mitsubishi Electric Hydronics & IT Cooling Systems, presents the mini chiller

More information

Blue Box Epsilon Echos +

Blue Box Epsilon Echos + Blue Box Epsilon Echos + 5 38 kw General information Air-Water unit with scroll compressors driven by DC inverter Packaged version in 5 sizes Nominal cooling capacity (A35;W7): 6 26 kw Nominal heating

More information

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS Total heat recovery multi-purpose units LCP Outdoor monobloc air-water unit LCP - kw Heating, cooling, domestic hot water one single system to meet all kinds of needs. Total heat recovery multi-purpose

More information

AIR TO WATER UNITS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS (PLUG FAN), FOR INDOOR INSTALLATION kw

AIR TO WATER UNITS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS (PLUG FAN), FOR INDOOR INSTALLATION kw PROCESS CHILLERS HEAT PUMPS AIR TO WATER UNITS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS (PLUG FAN), FOR INDOOR INSTALLATION 17-290 kw climaveneta.com PROCESS CHILLERS HEAT PUMPS A TRULY UNIQUE SOLUTION

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are

More information

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are

More information

Neosys Product catalogue

Neosys Product catalogue 00/0 Neosys Product catalogue Providing indoor climate comfort NEOSYS 00 0 kw Air cooled chiller/heat pump YEAR WARRANTY* Quality makes the difference* Introduction to the range NEOSYS is providing chilled

More information

PRODUCT GUIDE

PRODUCT GUIDE PRODUCT GUIDE 01.2017 Cooling Heating CHAPTER 1 AIRCOOLED LIQUID CHILLERS AND HEAT PUMPS FOR RESIDENTIAL & LIGHT COMMERCIAL APPLICATION Power (kw) Page IACAK/II/WP 101.5 106 0 58 115 A CLASS energy efficiency

More information

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw Air cooled chillers with brushless oil-free compressors R-134a RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw External installation with very low sound level Cooling circuit with

More information

ERACS2-WQ. Climaveneta Technical Bulletin ERACS2_WQ_0802_3202_201110_EN. Units for 4 pipes-systems water source kw

ERACS2-WQ. Climaveneta Technical Bulletin ERACS2_WQ_0802_3202_201110_EN. Units for 4 pipes-systems water source kw Climaveneta Technical Bulletin ERACS2_WQ_0802_3202_201110_EN 0802-3202 185-850 kw Units for 4 pipes-systems water source (The photo of the unit is indicative and may change depending on the model) Unique

More information

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X EPCE00-10B Powerful air cooled Hydronic systems EUWA*40-200K(A)X Development Environment Technology 2 Daikin s pre-eminent position in air conditioning and chiller production has been built on over 70

More information

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The

More information

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:

More information

AWR-HT. Climaveneta Technical Bulletin

AWR-HT. Climaveneta Technical Bulletin Climaveneta Technical Bulletin 0404 0604 High efficiency reversible heat pump, air source for outdoor 116 181 kw installation, high water temperature (The photo of the unit is purely indicative and may

More information

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata EKS/HE Refrigerant R410A GWP=2.088 Scroll Compressor Shell & Tube exchanger Axial fan Brazed plate heat exchanger MultiScroll Air-cooled liquid chillers High efficiency Solution B - Base I - Integrata

More information

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS RAH 602 Ka + CF + GP 62 Above picture is only indicative and is not binding.

More information

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to 1.99 kw Centrifugal compressor with magnetic levitation This is a miniaturized, highly innovative

More information

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98 Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw Scroll Compressors Series: SCAEY-FC Leaflet: DE 98 Issue: 04/11 Supersedes: 12/10 Identification code Index Index... pag. 2 Identification code...»

More information

LZT High efficiency air to water heat pumps with E.V.I. compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors High efficiency air to water heat pumps with E.V.I. compressors -20 C +43 C +65 C E.V.I. C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating

More information

ELFOEnergy SHEEN. Technical Bulletin. Air source inverter heat pump for outdoor installation. WSAN-XSi RANGE HIGH SEASONAL EFFICIENCY

ELFOEnergy SHEEN. Technical Bulletin. Air source inverter heat pump for outdoor installation. WSAN-XSi RANGE HIGH SEASONAL EFFICIENCY Technical Bulletin BT17I022GB-00 ELFOEnergy SHEEN Air source inverter heat pump for outdoor installation WSAN-XSi 10.1 22.2 RANGE Nominal heating capacity (A7/W45) from 23,3 to 61 kw Nominal cooling capacity

More information

BRAT MC. Climaveneta Technical Bulletin BRAT_MC_0011_0121_201311_EN Condensing units 5,63 35,8 kw

BRAT MC. Climaveneta Technical Bulletin BRAT_MC_0011_0121_201311_EN Condensing units 5,63 35,8 kw Climaveneta Technical Bulletin BRAT_MC 3_EN Condensing units 5,63 35,8 kw (The photo the unit is indicative and may change depending on the model) Flexibility Adaptability SL supersilenced version available

More information

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning : Packaged air cooled liquid chillers with free-cooling system for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 314 1343 Free-Cooling Capacity: 308 938 GLYCOL

More information

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1 UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS GPE 802 Kc + CF + GP + MV + P1 130 Above picture is only indicative and is not binding. AIR R-410A

More information

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES Air to water chillers and heat pumps The water chillers range have been designed for small and medium residential and commercial applications. The water chillers are suitable for water outlet temperatures

More information

Ultimate energy saving technology

Ultimate energy saving technology Ultimate energy saving technology CWT Chiller Series CWt purestream series water chillers The new CWT Purestream chiller range is specifically designed to meet the stringent cooling requirements of today

More information

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB R407C EASY_R Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans 5,2 41,5 kw T_ESY_R_0508_GB EASY_R R407C INDEX WORKING LIMITS... 3 SERIES IDENTIFICATION... 4 MODEL

More information

PYXIS U PYXIS U. rcgroupairconditioning

PYXIS U PYXIS U. rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44 284 rcgroupairconditioning MIN FETURES

More information

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW TECHNICAL CATALOGUE EQSL Air Cooled Water Chillers Models: 300 V2 F06 1310 V2 F16 Cooling capacity: 299 to 1310 KW 02.16 ref. 207598 Rev.100 Thank you for trusting in Hitecsa Products. Our company has

More information

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual u Air-to-Water Reverse Cycle Heat Pumps AQH 40 to 130 40 to 131 kw 45 to 141 kw Engineering Data Manual EDM AQH-W.3GB Date : November 2007 Supersedes : TM AQH-W.2GB/03.04 Specifications The Aqu@Logic air-to-water

More information

30RH B Nominal cooling capacity kw Nominal heating capacity kw

30RH B Nominal cooling capacity kw Nominal heating capacity kw Air-to-Water Heat Pumps with Integrated Hydronic Module AQUASNAP Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products.

More information

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED EQV R-407C WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED Size Cooling Heating [kw] [kw] 5 1,9 2,2 7 2,4 2,5 9 2,6 2,5 15 3,3 3,2 17 3,7 3,7 REPLACE: BT02E008GB-01 The Versatemp EQV units

More information

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw COMFORT HEAT PUMPS AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw climaveneta.com COMFORT HEAT PUMPS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air to water heat pump for outdoor installation,

More information

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING

More information

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10 Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW Compressors Scroll Serie: Series: Emissione: Issue: SCAEY Catalogo: Leaflet: Sostituisce: Supersedes: DE 88 04/11 12/10 Index

More information

44,9 202,0 kw. technicalcatalogue

44,9 202,0 kw. technicalcatalogue Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressor and microchannel condensing coils 44,9 202,0 kw technicalcatalogue T_PYXU_0413_GB INDEX EUROVENT CERTIFICATION...

More information

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES LS ir cooled water chillers with axial fans + LS The LS water chiller range has been designed for small and medium residential and commercial applications. They are suitable for generating chilled water

More information

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY Easy and fast installation Hydronic module available Compact, reliable and efficient Nominal cooling capacity : 8-40 kw Nominal heating capacity : 17-40 kw 50 410A Cooling or heating USE The air-to-water

More information

GLIDER EVO GLIDER EVO. rcgroupairconditioning

GLIDER EVO GLIDER EVO. rcgroupairconditioning : Packaged air cooled liquid chillers for outdoor installation equipped with screw compressors and axial fans Cooling Capacity: 300 1313 rcgroupairconditioning R134a SHELL C MIN FETURES ir cooled liquid

More information

pyxis u pyxis ua NEW rcgroupairconditioning

pyxis u pyxis ua NEW rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44,9 200,0 rcgroupairconditioning R410 C PLTE

More information

black Thermal power (A7:W45) kw Cooling power (A35;W7) kw

black Thermal power (A7:W45) kw Cooling power (A35;W7) kw black Thermal power (A7:W45) 35 60 kw Cooling power (A35;W7) 32 56 kw High efficiency and high temperature air/water heat pump with axial fans and scroll compressors 134a H 2 O 80 CONTROL MINIBOSS black

More information

Aquaflair TRAC-TRAF-TRAH

Aquaflair TRAC-TRAF-TRAH Aquaflair TRAC-TRAF-TRAH 110 400 kw Air-cooled chillers, free-cooling chillers and heat pumps for mission critical applications Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors

More information

ERACS2-Q. Climaveneta Technical Bulletin ERACS2_Q_1062_3222_201110_EN kw

ERACS2-Q. Climaveneta Technical Bulletin ERACS2_Q_1062_3222_201110_EN kw Climaveneta Technical Bulletin ERACS2_Q_1062_3222_201110_EN 1062-3222 200-826 kw INTEGRA unit for 4-pipe systems, air source for outdoor installation (La foto dell unità è indicativa e potrebbe variare

More information

AQUASNAP JUNIOR 30RHV

AQUASNAP JUNIOR 30RHV High-Efficiency Air-To-Water Heat Pumps Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. AQUASNAP JUNIOR 3RHV 6-11

More information

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw PROCESS CHILLERS AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com PROCESS CHILLERS MAXIMUM EFFICIENCY IN EVERY TYPE OF PROCESS APPLICATION Air cooled liquid chiller for outdoor

More information

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors infolinia: +48 691 262 691-15 C +63 C +43 C E.V.I. HP The series of high efficiency heat pumps has been specifically designed for use with

More information

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 46 Above picture is only indicative and is not binding AIR FC The packaged air cooled chillers of RAS Kp series are suitable

More information

GLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning

GLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning GLIDER EVO CL GLIDER EVO CL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 282 1513 HIGHEFFICIENCY

More information

1

1 ST www.coldinnovation.it 1 INDEX Available versions...pag. 4 Structure of electro-galvanized and painted steel sheet...pag. 5 Ecological refrigerant R410A...pag. 5 Scroll compressors...pag. 6 Condenser

More information

Ultimate energy saving technology

Ultimate energy saving technology Ultimate energy saving technology CWT Chiller Series CWt purestream series water chillers The new CWT Purestream chiller range is specifically designed to meet the stringent cooling requirements of today

More information

kw. technicalcatalogue

kw. technicalcatalogue Packaged air cooled liquid chillers in A class energy efficiency for outdoor installation equipped with scroll compressor and microchannel condensing coils 108 876 kw technicalcatalogue T_PYXCLA_0413_GB

More information

LZA High efficiency air to water heat pumps with HP compressor

LZA High efficiency air to water heat pumps with HP compressor High efficiency air to water heat pumps with HP compressor -10 C +43 C +60 C HP C.O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG + Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG + Quality Management Systems 30RBY/RQY 017-033 Nominal cooling capacity 15-33 kw Nominal heating capacity 17-31 kw The new

More information

pyxis pyxisa NEW rcgroupairconditioning

pyxis pyxisa NEW rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 119,0 808,0 PLTE C rcgroupairconditioning

More information

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: 40-158 kw Nominal heating capacity: 41-159 kw Carrier China Carrier Corporation is a subsidiary of the United Technologies

More information

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS Indoor motor-driven evaporating units LER 0-0 kw Compact and silent machines with remote dissipation into the air Scroll compressor PLUS R-0A R-0A refrigerant Cooling only Split version Electronic expansion

More information

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating. capacity: Heating capacity: 20,8 to 135,1 kw 22,6 to 144,7 kw Scroll compressors R-410A refrigerant Confi guration fl exibility Silent operation DESCRIPTION The AirDuo cooling units and are units which

More information

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

HYDROCIAT LW R407C. Water cooled chillers USE RANGE Screw compressors CIAT dry direct expansion shell and tubes evaporator HPS equipment (High Power System) cooling or heating Heat recovery ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT

More information

ULTIMATE ENERGY SAVING TECHNOLOGY

ULTIMATE ENERGY SAVING TECHNOLOGY ULTIMATE ENERGY SAVING TECHNOLOGY CWM CHILLER SERIES CWM PURESTREAM SERIES WATER CHILLERS The new CWM Purestream chiller range is specifically designed to meet the stringent cooling requirements of today

More information

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw COMFORT CHILLERS AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw climaveneta.com COMFORT CHILLERS PERFECT COMFORT AND MAXIMUM EFFICIENCY Air-cooled liquid chiller for outside installation

More information