1 EarthLinked CC Series Compressor Unit R-410A Quik-Start Instructions CONTENTS PAGE Pre-Installation 3 Placement & Mechanical Information 4 System Application Options 11 Desuperheater Kit 15 Anti-Freeze Protection 19 Electrical and Sound Data Internal Wiring Internal Wiring 23 Field Wiring Diagram 25 System Start-Up 27 Evacuation 27 Initial Charge 27 Final Charge 32 Cooling Mode Start-Up 34 CC-410-QS (09/17) Inc. Copyright 2017 Earthlinked Technologies,
2 Disclaimer Proper installation and servicing of the EarthLinked Heating and Cooling System is essential to its reliable performance. All EarthLinked systems must be installed and serviced by an authorized, trained technician who has successfully completed the training class and passed the final examination. Installation and service must be made in accordance with the instructions set forth in this manual and the current EarthLinked Heating and Cooling Installation, Operation and Maintenance Manual. Failure to provide installation and service by an authorized, trained installer in a manner consistent with the subject manuals will void and nullify the limited warranty coverage for the system. READ THE CURRENT EarthLinked Heating and Cooling Installation, Operation and Maintenance Manual FOR COMPLETE INSTALLATION DETAILS. Earthlinked Technologies shall not be liable for any defect, unsatisfactory performance, damage or loss, whether direct or consequential, relative to the design, manufacture, construction, application or installation of the field specified components. CC-410-QS (09/17) Inc. Copyright 2017 Earthlinked Technologies,
3 Earthlinked Technologies, Inc South Pipkin Road Lakeland, Florida tel fax CSI # CC-410-QS (09/17)
4 Pre-Installation Upon receipt of the equipment, carefully check the shipment against the bill of lading. Reference EarthLinked matching system component model numbers in Figure 1. Make sure all units have been received and model numbers are the same as those ordered. Compressor Unit 1 Air Handler Cased Coil CCS COOL ONLY Applications Hydronic Water Module Desuperheater Water Heating Hybrid Cooling Module 3 Earth Loop C* 0024-C* -024 HWM C* 0036-C* C* 0048-C* HWM-4248 HRM-1872 HCM-1860C C* 0060-C* -060 HWM CV NA For CC compressor units: Contained in each compressor package: compressor unit four L-shaped hold down brackets service valves-liquid and vapor adapters for service valves and earth loop line set product literature 2. All series Earth Loops: V1, D1, V1.5, D1.5, V2, D2, H1B 3. HCMs are for CC compressor units. Note: Desuperheater EarthLinked thermostats can be utilized throughout capacity range. Figure 1. Model Numbers Cathodic Protection System EPS-KIT Guidelines for the general layout of the system components are shown in Figure 2. Before placing the compressor unit (outside or indoors), review the guidelines in Figure 2. CC-410-QS (09/17) Page 4
5 Figure 2. General System Layout Placement and Mechanical Information EarthLinked compressor units may be located outside or inside the building, following these guidelines. OUTSIDE Locate compressor unit: On a standard HVAC condensing unit pad, resting on firm, level, settled ground. Same as for INSIDE placement. See below. INSIDE Locate compressor unit: On a solid, level hard surface. If compressor unit is to be fastened, see Figure 3 for bracket installation. Where compressor unit sound and vibration will not disturb human activities. Compressor unit may be located in garage, basement, crawl space or utility room. Avoid placing compressor unit in kitchen, bedroom, family/living/dining room areas. In a condensate pan. On vibration pads. CC-410-QS (09/17) Page 5
6 Attic installations, where necessary, must include a drip pan, anti-vibration pads and are to be suspended from the rafters with suspension isolators. Where suggested clearance is 3 feet on both sides, top and front, for access. However, local codes and applicable regulations take precedence. Clearance from back panel to wall and minimum side clearance should be at least one foot. See Figure 4 for details. Where the total length of refrigerant line sets (from manifolds to compressor and from compressor to air handler) do not exceed 125 feet, as shown in Figure 2. Where the compressor unit is no more than 20 feet higher than the earth loop manifolds. Compressor unit may be located lower than the earth loop manifolds. See Figure 2. If the compressor unit or other refrigerant-containing system components are located indoors, they shall be in a location which (1) is an unoccupied space, or (2) is served by the circulating air system, or (3) provides 280 cu. ft. of open space per nominal ton of rated system capacity. The 2012 International Mechanical Code defines residential occupancy as including permanent provisions for living, sleeping, eating, cooking, and sanitation. Consult local code authorities to define unoccupied space for the specific installation. Figure 3. Compressor Unit Bracket Installation Figure 4. Compressor Unit Clearance CC-410-QS (09/17) Page 6
7 Compressor units are shipped from the factory with a low pressure nitrogen holding charge. Carefully relieve the holding charge when the compressor unit is being prepared to connect refrigerant system piping. The compressor unit package contains a service valve kit and an adapter kit. The two service valves are to be installed on the earth loop vapor and liquid connections of the compressor unit, using the adapters to right-size to the proper earth loop line set. Installation of the service valves will provide isolation of the earth loop system from the compressor unit and provide easy access to the refrigerant system. The service valve configuration provided is illustrated in Figure 4a. The valve stem is accessed by removing the cap. The service port is equipped with a Schrader valve insert. Figure 4a. Service Valve Orientation Complete service valve installation instructions are contained in the Service Valve Kit Installation Manual, included with the service valves. CC-410-QS (09/17) Page 7
8 CC-410-QS (09/17) Page 8
9 Figure 5. CC Connections for R-410A CC-410-QS (09/17) Page 9
10 System Application Options Figure 8. CC Air Heating CC-410-QS (09/17) Page 10
11 Figure 8a. CC Air Cooling (Chilled Water Air Handler) CC-410-QS (09/17) Page 11
12 Figure 8b. CC Air Cooling; Domestic Hot Water by Field-Installed Desuperheater Kit CC-410-QS (09/17) Page 12
13 Figure 8c. CC Air Cooling (Chilled Water Air Handler) and Domestic Hot Water by Field Installed Desuperheater Kit CC-410-QS (09/17) Page 13
14 Desuperheater Kit The field installed ETI Desuperheater Kit Model DSH-1872 equips the CC Series Compressor Unit with supplemental water heating capability during cooling mode operation. Typical water piping installed with an existing or new standard storage water heater is illustrated in Figure 8d. Water piping for the desuperheater installed with an ETI Model GSTE Storage Water Heater is illustrated in Figure 8e. The GSTE Series Storage Water Heater is available in 60, 80 and 119 gallon capacities with water piping connections built into the top of the storage water heater specifically for use with the desuperheater. All GSTE Series models are equipped with a 4.5 kw electric heater and provide the following hot water recovery rates in gallons per hour, for a range of water temperature increases, in degrees Fahrenheit. ΔT GPH *ΔT in ºF; GPH in U.S. Gallons per hour. Field wiring for the DSH-1872 Kit is illustrated in Figure 8f for water heating during cooling system operation. See the EarthLinked Model DSH-1872 Desuperheater Installation Manual for the SC and CC Compressor Units, for complete installation details. CC-410-QS (09/17) Page 14
15 Figure 8d. Desuperheater Installed with Existing or New Standard Storage Water Heater CC-410-QS (09/17) Page 15
16 Figure 8e. Desuperheater installed with GSTE Storage Water Heater. CC-410-QS (09/17) Page 16
17 Figure 8f. Field Wiring for Desuperheater Kit CC-410-QS (09/17) Page 17
18 Antifreeze Protection When HWM hydronic water modules are applied to chilled water cooling systems, the water circulating system must be protected from potential damage due to freeze-up by utilizing an adequate antifreeze solution. The antifreeze protection is provided by the installer prior to the EarthLinked system start-up. Propylene-glycol antifreeze solution with an inhibitor is the type of antifreeze solution required for Earthlinked products utilized in radiant panel hydronic heating and/or chilled water cooling systems. These systems shall be freeze protected consistent with the application -specific minimum temperature, as shown in the table below. Propylene-glycol antifreeze solutions should always be in the range of 20% to 50% by volume, as indicated in the table. WATER SOLUTION MULTIPLIER FACTOR (WSMF) x x x x 1.16 Propylene Glycol Freeze Protection Table TEMPERATURE, F PROPYLENE GLYCOL, % Propylene-glycol can be purchased in the straight form and mixed with an inhibitor prior to filling the system, or it can be purchased as inhibited propylene-glycol. The following are examples of manufacturers for the above: Straight propylene-glycol: Chemical Specialties, Inc. ( Inhibitor: Nu-Calgon Products, Ty-lon B20 ( Inhibited propylene-glycol: Houghton Chemical Corp., SAFE-T-THERM, CC-410-QS (09/17) Page 18
19 General guidelines for introducing propylene glycol into the water circulating system follow. The manufacturer s specific instructions and industry standards always take precedence when introducing propylene-glycol to the system. Calculate the quantity of inhibited propylene-glycol (fluid) required to achieve the desired results. Introduce a sufficient quantity of water to the system and pressure check to ensure a sealed system. Drain some water from the system to provide enough volume for the calculated amount of fluid. Add the correct amount of fluid and any water needed to completely refill the system, allowing for liquid expansion due to operating temperature. Circulate the inhibited propylene-glycol antifreeze solution for at least 24 hours to ensure complete mixing. Check the liquid concentration to assure that the correct mixture is obtained. Electrical and Sound Data Compressor Unit - Model Compressor Model Voltage/ Phase/ Hz Voltage Min. Max. LRA RLA MCA MFS Sound Pressure Level ft, db(a) C ZP24K5E-PFV C ZP24K5E-TF C ZP36K5E-PFV C ZP36K5E-TF C ZP49K5E-PFV C ZP49K5E-TF /-068-1C ZP57K5E-PFV /-068-2C ZP57K5E-TF LRA = Locked Rotor Amps RLA = Rated Load Amps MCA = Minimum Circuit Ampacity MFS = Maximum Fuse or HACR Circuit Breaker Size (External) AWG = Consult NEC and Local Codes *Data Source is published Copeland Compressor Sound Power Levels converted to Sound Pressure Level in db(a) at 10 Feet, having two reflective surfaces. Effects of ETI compressor unit cabinet and components not included. Figure 9. Compressor Unit Electrical and Sound Data CC-410-QS (09/17) Page 19
20 Figure 10. CC Electrical Ladder Diagram ( ) CC-410-QS (09/17) Page 20
21 Figure 11. CC Electrical Schematic ( ) CC-410-QS (09/17) Page 21
22 Figure 12. CC Series Electrical Ladder Diagram CC-410-QS (09/17) Page 22
23 Figure 13. CC Series Electrical Schematic CC-410-QS (09/17) Page 23
24 Figure 14. (Part 1 of 2) CC Field Wiring Diagram CC-410-QS (09/17) Page 24
25 Figure 14. (Part 2 of 2) CC Field Wiring Diagram CC-410-QS (09/17) Page 25
26 System Start-up 1) System Leak Check After all indoor and outdoor refrigerant bearing components of the system have been installed and joints have been nitrogen brazed, pressurize the system prior to evacuation to leak test the system. Do not exceed 150 psig when pressure testing the compressor unit and indoor system components. Test for leaks with a sensitive electronic leak detector and bubble solution. Repair leaks as appropriate prior to evacuation. CAUTION! During the Evacuation and Initial Charging processes, be sure that ALL power to the EarthLinked System is OFF. This includes the compressor unit, air handler and all other electrically powered system components. Failure to do so will cause lockout on start-up. CC-410-QS (09/17) Page 26
27 2) Evacuation 1) Carefully vent the nitrogen charge from the compressor unit. 2) It is recommended to use two Schrader core removal tools. One installed on the suction port located on the ¼ line between the TXV and the accumulator, and the other installed on the discharge line of the compressor. Removal of the Schrader cores will greatly reduce the time to achieve the desired vacuum. 3) Attach a good quality manifold gauge and hose set to the Schrader core removal tools. The low-side hose should be attached to the pre-charge port and the high-side hose to the discharge port. The same manifold gauge and hose set will later be used in this position for pre-charging the system as well 4) Attach a good quality micron gauge to the charging hose of your manifold gauge set using either one with a pass through design or a Tee. 5) Using another hose, attach the micron gauge to a well maintained, high quality vacuum pump with an isolation valve, 7 CFM or greater is recommended. If your vacuum pump does not have an isolation valve, you will need to install one between the vacuum pump and micron gauge. Ensure that the vacuum pump oil has been changed prior to initiating the evacuation process to avoid contamination. 6) Open both valves of your manifold gauge set. Open the vacuum pump isolation valve and start the pump. Evacuate the system down to 400 MICRONS or less as read on the micron gauge. IMPORTANT! DO NOT ENERGIZE THE COMPRESSOR WHILE THE SYSTEM IS UNDER VACUUM. THIS WILL CAUSE DAMAGE TO THE COMPRESSOR. CC-410-QS (09/17) Page 27
28 After 400 microns or less has been achieved, close the isolation valve between the micron gauge and vacuum pump and wait 5 minutes before reading the micron gauge. The system pressure must not exceed 500 MICRONS WITHIN 5 MINUTES. If it does, continue the evacuation to remove any remaining non-condensibles in the system. A dry system will hold 500 microns for 5 minutes. A procedure often used to evacuate a system, known as the triple evacuation method, is detailed in the section of this manual entitled Triple Evacuation. Local codes may require other evacuation criteria, in which case the local codes take precedence over the evacuation requirements described above. IMPORTANT! DO NOT CHARGE THE SYSTEM UNTIL THE CONDITIONS OF STEP #6 ARE COMPLETED! 7) When the system has been successfully evacuated, valve off your manifold gauge set and move on to the charging procedure. DO NOT remove the manifold gauge or hoses prior to pre-charging as air will be drawn into the system, defeating the vacuum process. Only after the system is under refrigerant pressure by pre-charging should you remove the CC-410-QS (09/17) Page 28
29 3) Initial Charge 1) With your manifold gauge set still connected to the Schrader core removal tools, connect your refrigerant drum to the charging hose of your manifold gauge set. Never remove or change hoses while a unit is under vacuum. WARNING! Inhalation of high concentrations of refrigerant gas vapor is harmful and may cause heart irregularities or death. Vapor reduces oxygen available for breathing and is heavier than air. Decomposition products are hazardous. Liquid contact can cause frostbite. Avoid contact of liquid with eyes and prolonged skin exposure. Liquid and gas are under pressure. Deliberate inhalation of refrigerant gas is extremely dangerous. Asphyxiation can occur without warning due to lack of oxygen. Before using, read the material safety data sheet. Use proper safety measures when charging the system, especially when warming the refrigerant container. Do not overheat. 2) Open your refrigerant drum s valve and place the drum upside down (or oriented to deliver liquid refrigerant) - with the refrigerant valve at the bottom so as to charge refrigerant in a liquid state - and place it on a refrigerant scale. 3) Purge the charging hose by loosening it at the manifold end, until refrigerant is released. Re-tighten the charging hose and zero out your refrigerant scale. 4) Open the low-side valve of your manifold gauge set, this sends liquid refrigerant to the pre-charge port on the rail assembly only. Continue to add refrigerant until 3 lbs. per system ton has been added. In cold weather, it may be necessary to warm the refrigerant container to charge to 3 pounds per ton. CC-410-QS (09/17) Page 29
30 4) Final Charge 1) Start the air handler while keeping the compressor off and verify that the airflow meets the design target of 400 CFM/ton 2) Place a temperature clamp or probe securely to the air handler/cased coil vapor line at the rear of the compressor unit approximately 6 inches away from the rear. Check and record both the suction pressure and the air handler/cased coil suction line temperature. Use a pressure-temperature chart and verify the unit is operating with 6 to 12 degrees of superheat while in cooling mode. If the superheat is higher than 12 degrees, add refrigerant slowly until the superheat falls between 6 and 12 degrees. If the superheat is lower than 6 degrees, remove refrigerant slowly until the superheat rises between 6 and 12 degrees. Please note that there is an inline site glass prior to the unit s TXV. While in cooling mode, this inline sight glass may never clear. This is normal and no more refrigerant should be added. Should the inline sight glass clear while suction superheat is still over 12 degrees, the TXV will need adjustment. At this time, do not add more refrigerant and follow the next step. 3) Remove the cap from over the TXV adjustment nut. Using a refrigerant wrench, turn the TXV one full counter-clockwise turn and wait 5 minutes. Recheck the suction superheat. Adjust again in a counter-clockwise rotation if needed, waiting 5 minutes between each turn. No more than 3 counter-clockwise turn should be needed to set the suction superheat. 4) If any issues arise during any of these procedures, or, suction superheat is not correct after 3 counter-clockwise turns of the TXV, please contact EarthLinked Technical Support for assistance. 5) The system is now fully charged and operational in heating and cooling modes. Document the weight of the Total refrigerant charge in the system. Write it down on the Warranty Registration Card and inside the compressor unit on the electrical diagram, for future reference. CC-410-QS (09/17) Page 30
31 TEMPERATURE ( F) PRESSURE (psig) Pressure-Temperature for R-410A CC-410-QS (09/17) Page 31
EarthLinked SCW Series Compressor Unit R-410A Quik-Start Instructions
EarthLinked SCW Series Compressor Unit R-410A Quik-Start Instructions CONTENTS PAGE Pre-Installation 3 Placement & Mechanical Information 6 System Application Options 12 Antifreeze Protection 13 Electrical
More informationEarthLinked HC Series Compressor Unit R-410A Quik-Start Instructions
EarthLinked HC Series Compressor Unit R-410A Quik-Start Instructions CONTENTS PAGE Pre-Installation 3 Placement & Mechanical Information 4 System Application Options 11 Antifreeze Protection 14 Electrical
More informationEarthLinked SW Series Compressor Unit R-410A Quik-Start Instructions
EarthLinked SW Series Compressor Unit R-410A Quik-Start Instructions CONTENTS PAGE Pre-Installation 3 Placement & Mechanical Information 4 System Application Options 10 Antifreeze Protection 14 Electrical
More informationEarthLinked SC Series Compressor Unit R-407C Quik-Start Instructions
EarthLinked SC Series Compressor Unit R-407C Quik-Start Instructions CONTENTS PAGE Pre-Installation 3 Placement & Mechanical Information 4 System Application Options 11 Desuperheater Kit 15 Antifreeze
More informationInstallation Manual for. Series HWM and Non-ETI HYDRONIC WATER MODULE with SC and SD COMPRESSOR UNITS and R-410 REFRIGERANT
EarthLinked TXV Kit Installation Manual for Series HWM and Non-ETI HYDRONIC WATER MODULE with SC and SD COMPRESSOR UNITS and R-410 REFRIGERANT CONTENTS PAGE Pre-Installation 3 Hydronic Water Module Conversion
More informationInstallation Manual for ETI AVS Series and NON-ETI Air Handlers with SC or SD Compressor Units and R-410A Refrigerant
EarthLinked TXV Kit Installation Manual for ETI AVS Series and NON-ETI Air Handlers with SC or SD Compressor Units and R-410A Refrigerant CONTENTS PAGE Pre-Installation 3 Air Handler Conversion 4 System
More informationInstallation Manual for CCS Cased Coils with SC, SD, SW Compressor Units and R-410A Refrigerant
EarthLinked TXV Kit Installation Manual for CCS Cased Coils with SC, SD, SW Compressor Units and R-410A Refrigerant CONTENTS PAGE Pre-Installation 3 Cased Coil Conversion 4 System Start-Up 17 TXV CCS-410-KIT
More informationEarthLinked SD(A) Series
EarthLinked SD(A) Series Geothermal Heating and Cooling System Quick-Start Instructions SD-410-QS(A) (11/14) Copyright 2014 Earthlinked Technologies, Inc. Table of Contents Model Nomenclature... 5 Safety...
More informationEarthLinked Model DSH-1872 Desuperheater Kit
EarthLinked Model DSH-1872 Desuperheater Kit for SC and CC Compressor Units CONTENTS PAGE Desuperheater Kit Information 3 Desuperheater Mechanical Installation 9 Desuperheater Electrical Installation 17
More informationHeat Recovery Module Installation Manual for
Heat Recovery Module Installation Manual for Classic and Prime Select Systems CONTENTS PAGE Desuperheater Kit Information 3 Desuperheater Mechanical Installation 9 Desuperheater Electrical Installation
More informationAVS Series Air Handlers Installation Manual for CLASSIC SERIES SYSTEMS Models SC, SD, and SDH
AVS Series Air Handlers Installation Manual for CLASSIC SERIES SYSTEMS Models SC, SD, and SDH AVS-ACL-IM (08/15) Copyright 2015 Earthlinked Technologies, Inc. Table of Contents Model Nomenclature... 4
More informationEarthLinked AVN Series Air Handlers Installation Manual
EarthLinked AVN Series Air Handlers Installation Manual AVN-410-IM (03/14) Copyright 2014 Earthlinked Technologies, Inc. Table of Contents Model Nomenclature... 4 Safety... 5 Equipment Manuals... 5 Installation...
More informationAVS Air Handlers Installation Manual for Classic SC, SD, and SDH
AVS Air Handlers Installation Manual for Classic SC, SD, and SDH AVS-NCL-IM (12/15) Copyright 2015 Earthlinked Technologies, Inc. Table of Contents Model Nomenclature... 4 Safety... 5 Equipment Manuals...
More informationClassic Series SD Geothermal Heating and Cooling System
Classic Series SD Geothermal Heating and Cooling System Quick-Start Instructions SD-QS (12/16) 2016 EarthLinked Technologies, Inc. Table of Contents List of Revisions... 4 Model Nomenclature... 5 Safety...
More informationEarthLinked Freeze Protection Kit Model FP-1872 Installation Manual
EarthLinked Freeze Protection Kit Model FP-1872 Installation Manual CONTENTS PAGE Pre-Installation 2 Mechanical Installation 4 SCW Compressor Unit 4 HWM Hydronic Water Module 8 Electrical Installation
More informationPrime Series PSDH Geothermal Heating and Cooling System
Prime Series PSDH Geothermal Heating and Cooling System Quick-Start Instructions PSDH-QS (12/16) 2016 EarthLinked Technologies, Inc. Table of Contents List of Revisions...... 4 Model Nomenclature......
More informationEarthLinked AFN Series Air Handlers Installation Manual
EarthLinked AFN Series Air Handlers Installation Manual AFN-410-IM (07/15) Copyright 2015 Earthlinked Technologies, Inc. Table of Contents Model Nomenclature... 4 Safety... 5 Equipment Manuals... 5 Installation...
More informationPrime Series PSDH Geothermal Heating and Cooling System
Prime Series PSDH Geothermal Heating and Cooling System Quick-Start Instructions PSDH-QS (06/16) 2016 EarthLinked Technologies, Inc. Table of Contents List of Revisions... 4 Model Nomenclature... 5 Safety...
More informationEarthLinked STORAGE WATER HEATER / HYDRONIC BUFFER TANK MODELS GSTE-60, GSTE-80 & GSTE-119
EarthLinked STORAGE WATER HEATER / HYDRONIC BUFFER TANK MODELS GSTE-60, GSTE-80 & GSTE-119 Installation, Operation & Maintenance Manual Disclaimer The EarthLinked Storage Water Heater is sold as a component
More informationClassic Series SC Geothermal Heating and Cooling System
Classic Series SC Geothermal Heating and Cooling System Quick-Start Instructions SC-QS (03/16) 2016 EarthLinked Technologies, Inc. Table of Contents List of Revisions... 4 Model Nomenclature... 5 Safety...
More informationPrime Series PSC Geothermal Heating and Cooling System
Prime Series PSC Geothermal Heating and Cooling System Quick-Start Instructions PSC-QS (02/16) 2016 EarthLinked Technologies, Inc. Table of Contents List of Revisions... 4 Model Nomenclature... 5 Safety...
More informationAVS Air Handlers Prime PSC, PSD, PSDH and Classic SC, SD, and SDH
AVS Air Handlers Prime PSC, PSD, PSDH and Classic SC, SD, and SDH Installation Manual AVS-IM (03/16) 2016 EarthLinked Technologies, Inc. Table of Contents List of Figures... 3 List of Revisions... 3 Model
More informationEARTHLINKED GEOTHERMAL RENEWABLE ENERGY SYSTEMS MAINTENANCE GUIDE
EARTHLINKED GEOTHERMAL RENEWABLE ENERGY SYSTEMS MAINTENANCE GUIDE This guide is directed at EarthLinked trained and authorized technicians servicing and maintaining the system and should be left with the
More informationDLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS
DLCLRA INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 Fig. 1 - Size 36 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4 WIRING...
More informationEarthLinked Series PHXTI Pool Heat Exchangers Installation Manual
EarthLinked Series PHXTI Pool Heat Exchangers Installation Manual CONTENTS PAGE Pre-Installation 3 Installation 3 Water Connections 4 Refrigerant Connections 7 Freeze Protection/Winterizing 11 PHXTI-IM
More informationInstallation Instructions
38MHR Outdoor Unit Single Zone Ductless System Sizes 09 to 24 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. NOTE: Images are for illustration purposes
More informationOperation and Maintenance Manual
Warranty Information Ritchie Engineering guarantees YELLOW JACKET products to be free of defective material and workmanship which could affect the life of the product when used for the purpose for which
More informationRecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual
RecoverX Oil-Filled Hermetic Refrigerant Recovery System Operation and Maintenance Manual Table of Contents Page General Safety Instructions 2-3 System Overview 3 Operating Guide 4 Restart Procedure 4
More informationDLCSRA. INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 TABLE OF CONTENTS
DLCSRA INSTALLATION INSTRUCTIONS Outdoor Unit Ductless Split System Sizes 09 to 36 NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes only.
More informationR100 Oil-Less Refrigerant Recovery Unit
R100 Oil-Less Refrigerant Recovery Unit Operation Manual 1 INTRODUCTION Welcome to simple, efficient refrigerant recovery with your new YELLOW JACKET Refrigerant Recovery Unit, R100. This unit combines
More informationG Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton
G Series ENCASED/UNCASED AIR COILS Geothermal/Water Source Heat Pumps R-410A Refrigerant 2- Ton Dimensional Data G Series Air Coils Installation ti Manual Installation Information Maintenance IM1018AG1
More informationMAC N-407 Air-Cooled Chiller
MAC036-01-N-407 Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial MicroClimates MAC036 NOMENCLATURE BREAKDOWN MAC036-01 - N - 407 Refrigerant Type Air-Cooled Chiller 036=
More informationTABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13
R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.
More informationR.A.S.E.R.S System. Installation Guide
R.A.S.E.R.S System Installation Guide Contents R.A.S.E.R.S System components... 1 Required components for heating, cooling, and hot water...1 Provided...1 Not provided...2 Optional components...3 R.A.S.E.R.S
More informationINSTALLATION AND OPERATING INSTRUCTIONS
INSTALLATION AND OPERATING INSTRUCTIONS HIGH-EFFICIENCY CONDENSING UNITS RAWD- 6 1 2 & 7 1 2 TON RAWE - 6 1 2 & 7 1 2 TON! RECOGNIZE THIS SYMBOL AS AN INDICATION OF IMPORTANT SAFETY INFORMATION!! WARNING
More informationKITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M
2004 Lennox Industries Inc. Dallas, Texas KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04 Supersedes 503,249M Litho U.S.A. COMPRESSOR REPLACEMENT KIT INSTALLATION INSTRUCTIONS FOR COMPRESSOR
More informationCondensing Unit Installation and Operating Instructions
Bulletin WCU_O&I 01 June 2003 Condensing Unit Installation and Operating Instructions WCU Air Cooled Condensing Unit Table of Contents Section 1. Section 2. Section 3. Section 4. Section 5. Section 6.
More informationINSTALLATION INSTRUCTIONS TXV Horizontal Slab Coils WLSH
TXV Horizontal Slab Coils WLSH These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system
More informationMACH N-407 Heat Pump Air-Cooled Chiller
MACH060-01-N-407 Heat Pump Air-Cooled Chiller Heat Pump Air-Cooled Chillers for Global Residential and Light Commercial Microclimates MACH NOMENCLATURE BREAKDOWN MACH-060-01 - N - 407 Refrigerant Type
More informationInstallation Instructions
38MPRA Outdoor Unit Single Zone Ductless System Sizes 09 to 12 Installation Instructions NOTES: Read the entire instruction manual before starting the installation. Images are for illustration purposes
More informationInstallation Instructions
38MGQ Multi-Zone Ductless System Sizes 18, 27, 36 and 48 Installation Instructions NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...
More informationSome of these procedures need to be performed to conform to requirements of the Clean Air Act.
Leak Detection, Recovery, Evacuation and Charging Four basic service procedures used to repair and maintain a mechanical refrigeration system are leak detection, evacuation, recovery, and refrigerant charging.
More informationInstallation Owner Diagnostics
Installation Owner Diagnostics Split System Cooling Condensers Model CTA 7 1/2 to 15 Tons Models A and later Design Sequence CTA 090A***A 60 HZ 120A***A 60 HZ 120B***A 60 HZ 180B***A 60 HZ SS-SVN11A-EN
More informationRCM Refrigerant Module
Small Duct High Velocity Heating, Cooling and Home Comfort Systems RCM Refrigerant Module Installation Manual Manufactured By Module-RCM-Refrigerant-Module-Installation-0666 Refrigerant Modules (RCM) Fig.
More informationINSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD
TXV Horizontal Duct s EHD These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system
More informationINSTALLATION GUIDE. 4AC 14* ASA1 SERIES R-410a CONDENSING UNITS R-410A ATTENTION, INSTALLER! ATTENTION, USER!
4AC 14* ASA1 SERIES R-410a CONDENSING UNITS INSTALLATION GUIDE R-410A ATTENTION, INSTALLER! After installing the system, show the user how to turn off electricity to the unit. Point out control and switch
More informationINSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD
TXV Horizontal Duct s EHD These instructions must be read and understood completely before attempting installation. It is important that the Blower and Duct System be properly sized to allow the system
More informationPARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer
PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer 5/16 Rev. A 57-02509 2 Contents INTRODUCTION... 4 WARNING LABELS AND SAFETY INSTRUCTIONS... 5 PS SERIES PARALLEL
More informationDLCMRA. INSTALLATION INSTRUCTIONS Multi zone Outdoor Unit Ductless System Sizes 18, 27, 36 and 48 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS...
DLCMRA INSTALLATION INSTRUCTIONS Multi zone Outdoor Unit Ductless System Sizes 18, 27, 36 and 48 TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 GENERAL... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS... 4
More informationR Series Cooling Modules
TM Small Duct High Velocity Heating, Cooling and Indoor Air Quality Systems R Series Cooling Modules Models RCM-50 RCM-70 RM-100 Manufactured By Module-RCM/RM-Series-Installation-Manual-120113 Refrigerant
More informationOPERATION & MAINTENANCE MANUAL RHS680
OPERATION & MAINTENANCE MANUAL RHS680 Refrigerant Handling System 4075 East Market Street York, PA 17402 800-468-2321 tech@rtitech.com Manual P/N 035-80740-00 (Rev 1- May 22, 2001) TABLE OF CONTENTS Startup
More informationR Series Cooling Modules
R Series Cooling Modules Models RCM/RPM 50 RCM 70 RM 100 RM 140 Manufactured By Energy Saving Products Ltd. Standard ESP 105.03 Refrigerant Modules (RCM/RM) Fig. 02 - Mounting brackets The cooling coil
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS T CLASS TSA Series 6 to 20 Ton AIR CONDITIONERS 6 20 TONS 506147 01 06/11 Supersedes 3/11 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT The Clean Air Act
More informationWineZone Ceiling Mount Ductless Split 15
WineZone Ceiling Mount Ductless Split 15 Requires an HVAC technician to install and charge with R-22 refrigerant. Easy to install. Unit plugs into wall outlet. Industrial grade unit for longer life. Indoor
More informationCondensing Unit Installation and Operating Instructions
Bulletin ACU_O&I 02 August 2016 Condensing Unit Installation and Operating Instructions ACU Air Cooled Condensers Table of Contents Section 1. General Information... 2 Section 2. Refrigeration Piping...
More informationINSTALLATION INSTRUCTIONS
2016 Lennox Industries Inc. Dallas, Texas, USA INSTALLATION INSTRUCTIONS Elite Series XC16 Units AIR CONDITIONER 507161-01 8/2016 Litho U.S.A. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE General This
More informationMAC-120HE-03 Air-Cooled Chiller
MAC-120HE-03 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 380/415/460-3-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-03
More informationINSTALLATION AND COMMISSIONING MANUAL. Neos 100S Integra 20X, 30S, 35X, 40X, 50X
Installation Truck Refrigeration & Commissioning Manual: INSTALLATION AND COMMISSIONING MANUAL for Neos 100S Integra 20X, 30S, 35X, 40X, 50X Direct Drive Refrigeration Units 2017 Carrier Corporation Printed
More informationINSTALLATION INSTRUCTIONS TXV Coils for Manufactured Housing EMA
TXV Coils for Manufactured Housing EMA NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance,
More informationInstallation Instructions
24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons Installation Instructions Fig. 1-24AHA4 A07532 SAFETY CONSIDERATIONS Improper installation, adjustment, alteration,
More informationENGINEERING SPECIFICATIONS
ENGINEERING SPECIFICATIONS RH-24-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 24 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.
More informationINSTALLER'S GUIDE. ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
11-AC11D2-5 INSTALLER'S GUIDE ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES Models: Condensing Units 2A7A5024-048, 2A7A4018-060, 2A7A2018-060 & 2A7A1018-060 IMPORTANT
More informationENGINEERING SPECIFICATIONS
ENGINEERING SPECIFICATIONS RH-12-HAC-P-1L-C-SDE*F Horizontal Single Stage R410a Model Size 12 Reversing (Heating AND Cooling) 208/230-1-60VAC Liquid to Air Geothermal Heat Pumps Maritime Geothermal Ltd.
More informationWMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS
WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS **WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER** Altering the product or replacing parts with non authorized factory parts voids all warranty
More informationInstallation Manual BCS2000/3000
Installation Manual BCS2000/3000 Supplies Needed for Installation 1. 3/8 and 5/8 copper tubing. 2. 1/4 copper water supply 3. 1/4 condensate vinyl drain tube/tube clamps 4. Provide 120v 15A circuit for
More informationInstallation Instructions
38MGR Multi-zone Outdoor Unit Ductless System Sizes 18, 24, 30, 36 and 48 Installation Instructions TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 2 GENERAL... 2 PARTS LIST... 3 SYSTEM REQUIREMENTS...
More informationTemperature Control Kit Model HHK/CWK-1872
Temperature Control Kit Model HHK/CWK-1872 Installation instructions HHK/CWK-KIT (02/16) 2016 EarthLinked Technologies, Inc. Disclaimer Proper installation and servicing of this EarthLinked part is essential
More informationOPERATION & MAINTENANCE MANUAL AC860
OPERATION & MAINTENANCE MANUAL AC860 Refrigerant Handling System Manual P/N 035-80913-00 TABLE OF CONTENTS Startup & Safe Operation... 1 Introduction to the AC860... 2 Control Panel... 3 Keypad Functions...
More informationPACKAGE AIR CONDITIONER
PACKAGE AIR CONDITIONER FORM NO. ATZ-206 TZAA- HIGH EFFICIENCY SERIES NOMINAL SIZE 10 TON [35.2 kw] 10 TON MODEL [35.2 kw] This product is shipped with a nitrogen holding charge that must be vented prior
More informationINSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X
INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...
More informationI N STALLATIO N. VRC Series IOM-M Part Number
M ECHANICAL I N STALLATIO N O PERATION & MA I NTENANCE VRC Series IOM-M2-0916 Part Number 478603 Table of Contents Safety... 3 Special Design Requests... 3 Model Number Guide... 3 Clearances... 4 Lifting
More informationINSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X
INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. TABLE OF CONTENTS PAGE SAFETY CONSIDERATIONS... 1 INTRODUCTION... 1 INSTALLATION...
More informationCONDENSING UNITS SPLIT-SYSTEM COOLING 1.5 TO 5 TONS INSTALLATION INSTRUCTION MODELS H*DE018 THRU H*DE060 NOMENCLATURE GENERAL LIMITATIONS INSPECTION
INSTALLATION INSTRUCTION CONDENSING UNITS SPLIT-SYSTEM COOLING 1.5 TO 5 TONS Supersedes: 550.44-N1Y (1194) 550.44-N1Y (495) MODELS H*DE018 THRU H*DE060 035-11029 WARNINGS are given to alert the installer
More informationInstallation, Start-Up and Service Instructions
38AH044-134 Air-Cooled Condensing Units 50/60 Hz Installation, Start-Up and Service Instructions CONTENTS Page SAFETY CONSIDERATIONS...................... 1 INSTALLATION................................
More informationTRS21 IGNITION PROOF SERIES
TRS21 IGNITION PROOF SERIES 2 Cylinder Commercial Recovery Machine OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TRS21A, TRS21E TO BE OPERATED BY QUALIFIED
More informationOPERATING INSTRUCTIONS
OPERATING INSTRUCTIONS MODEL RLV-700 REFRIGERANT RECOVERY / RECYCLING UNIT (PATENTED) NATIONAL REFRIGERATION PRODUCTS 985 Wheeler Way Langhorne, PA 19047 (215) 638-8909 FAX (215) 638-9270 REVISED 03-21-2018
More informationINSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X
INSTALLATION INSTRUCTIONS Cased N, Horizontal ENH4X NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service,
More informationOWNER S MANUAL (English)
TRS600 IGNITION PROOF SERIES Refrigerant Recovery Machines OWNER S MANUAL (English) Français, Español, Deutsch and latest updates: www.cpsproducts.com Series: TRS600, TRS600K, TRS600S Evaluated for performance
More informationCONDENSING UNITS SPLIT-SYSTEM COOLING 6-1/3 TONS INSTALLATION INSTRUCTION MODELS H*DB076 NOMENCLATURE GENERAL LIMITATIONS INSPECTION REFERENCE
INSTALLATION INSTRUCTION CONDENSING UNITS SPLIT-SYSTEM COOLING 6-1/3 TONS Supersedes: Nothing 550.38-N6Y (1095) MODELS H*DB076 035-13578 WARNINGS are given to alert the installer that severe personal injury,
More informationMortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS
Mortex INSTALLATION INSTRUCTIONS AIR CONDITIONING & HEAT PUMP INDOOR COILS INTRODUCTION Please note that HUD Manufactured Home Construction and Safety Standard Section 3280.714, paragraph (a) and subparagraph
More informationOwner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532
Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationCorp L9 Revised HS27 SERIES UNITS SPECIFICATIONS. Model No. HS HS HS HS27-042
Service Literature Corp. 9619 L9 Revised 08 2004 HS27 SERIES UNITS HS27 The HS27 is a 14 SEER high efficiency residential split system condensing unit which features a scroll compressor. It operates much
More informationInstallation Manual BCS 1000/1500
Installation Manual BCS 1000/1500 Supplies Needed for Installation 1. Double insulated refrigerant line set. 2. 1/4 copper water supply 3. 1/4 condensate vinyl drain tube/tube clamps 4. Provide 120V 15A
More informationOwner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350
Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others
More informationAIR CONDITIONING. Carrier Corporation 2002 Cat. No
AIR CONDITIONING Carrier Corporation 2002 Cat. No. 020-016 1. This refresher course covers topics contained in the AIR CONDITIONING specialty section of the North American Technician Excellence (NATE)
More informationMAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationMAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.1 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationTSA WARNING. Service Literature TSA SERIES UNITS. 6, 7.5, 10, 12.5, 15 & 20 ton
Service Literature Corp. 0903 L1 Revised: March 2011 TSA SERIES UNITS TSA 6, 7.5, 10, 12.5, 15 & 20 ton The TSA units are designed for light commercial applications, with a remotely located blower coil
More informationPACKAGED AIR COOLED Product Data Catalog
PACKAGED AIR COOLED Product Data Catalog MODELS ASP-10A ASP-15A ASP-20A ASP-00P ASP-00F ASP-00G A MEMBER OF MARDUK HOLDING COMPANY, LLC The Leader in Modular Chillers ETL and CSA Approved CHILLER MODULES
More informationR-410A. NJ-10 thru -20, 4-Pipe Ton, 60 Hertz TABLE OF CONTENTS LIST OF TABLES LIST OF FIGURES
R-410A MODELS: 7.5-20 Ton, 60 Hertz NH-07 thru -20, 2-Pipe NJ-10 thru -20, 4-Pipe General.......................................... 2 Safety Considerations............................... 2 Reference......................................
More informationAir Conditioning Operation and Troubleshooting Matt Dunham
Air Conditioning Operation and Troubleshooting Matt Dunham Major Components (10 Minutes) Compressor heart of the system, causes refrigerant to flow by increasing the pressure of the refrigerant Metering
More informationInstallation Instructions
8GXM / 0GXM Multi---Split High---Wall Duct Free Split System 8GXM --- Size 18k, k, and 0k 0GXM --- Size 9k, 1k, and 18k Installation Instructions NOTE: Read the entire instruction manual before starting
More informationCS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)
CS*/CD*/CP* Series Air Cooled Condensing Units Operating and Installation Manual CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2) TABLE OF CONTENTS I. Receipt of Equipment 2 II. Piping...4 III. System
More informationMASS. MARITIME ACADEMY
MASS. MARITIME ACADEMY REFRIGERATION LAB OUTLINE Rev.3 Fall 2015 Table of Content Page Lab #1: Introduction to refrigeration system components, tools and procedures 1 Lab #2: Familiarization, operation,
More informationMAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.
MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.2 HVAC Guide Specifications Air-Cooled Liquid Chiller with Low Ambient
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS STELLAR AIR CONDITIONING UNIT SPLIT-SYSTEM COOLING CONTENTS GENERAL..................................... 2 NOMENCLATURE........................... 2 SAFETY...................................
More informationOcean Breeze Split System. General Installation Manual. Ocean Breeze 2951 SE Dominica Terrace Stuart, Florida Tel:
Ocean Breeze Split System General Installation Manual Ocean Breeze 2951 SE Dominica Terrace Stuart, Florida 34997 Tel: 772 220 0038 Warning: The Air Conditioning Unit is a pressurized system; potential
More informationOwner s Manual Refrigerated Compressed Air Dryers Model F-100
Owner s Manual Refrigerated Compressed Air Dryers Model F-100 Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing
More information*20D082-05NN* 20D082-05NN
2506 South Elm Street Greenville, IL 62246 www.enertechgeo.com info@enertechmfg.com HT Models Packaged Water-to-Air Horizontal Heat Pumps Engineering Data and Installation Manual Rev.: 25 May 2012D P/N:
More informationACU Split System Air Conditioners
Installation and Maintenance Manual IM-802 Group: Unitary Part Number: IM-802 Date: August 2005 Supersedes: March 2005 ACU Split System Air Conditioners 7-1/2 & 10 TON 2004 McQuay International IM-802
More information