1 Technical manual Blower Pack for direct in-space humidification 1 Pictures for illustrating puposes only

2 2 Pictures for illustrating puposes only

3 Presentation Characteristics This Blower Pack is a steam room ventilation unit which combines performance with design and efficiency with limited size for a maximum flowrate of 30 kg/h. It performs best in a room where the Relative Humidity and temperature does not exceed 75% and 60 C. This Blower Pack can be supplied either for 15 kg/h or 30 kg/h flowrates and can be used (in combination) for our complete lines of humidifiers CMC, MC2, RTH-LC and RTH-V2. Flowrate kg/h Weight (kg) Nb of fans db Supply (V)* Power (W) Blower Pack BP1 15kg/h maxi Blower Pack BP2 30kg/h maxi * standard production : 230V electrical supply 24 & 115 V electrical supplies : on request only Dimensions (mm) Steam hose connection Ø 40mm Steam hose connection Ø 25mm This section must be cut off before connection to a Ø 40 mm steam hose 3 Pictures for illustrating puposes only

4 Installation BP1 & BP2 SET ON TOP OF HUMIDIFIER The BP1 and BP2 can be installed on the top of the following humidifiers : ElectroVap CMC, MC2 5 to 30, RTH-LC 5 to 15 and RTH-V2 5 to 30. For the larger capacities, it should be installed separately and in combination (s.a. pict. 2, 3 and 4). For a correct steam dispersion, we would recommend that the minimal distances of installation given on pict. 1 be adhered to. The steam connection between the ventilation unit and the humidifier is ensured by a steam hose (either Ø 25 or 40 mm according to the model of humidifier). A Ø 60/40 mm adaptor union must be used for humidifiers RTH-V2 5 to 30. ElectroVap CMC with BP1 ventilation unit in operation Pict.1 Minimal distances ElectroVap MC2 with BP ventilation unit ElectroVap RTH-LC with BP ventilation unit 4 Pictures for illustrating puposes only

5 Installation Wall installation The BP1 & BP2 ventilation units can be wall mounted (s.a. pict. 2). It is essential that the minimal installation distances be met. In case of steam capacities superior to 30 kg/h such as for humidifiers RTH-V2 40 & 50, a combination of two BP2s will be required. In such a case, a Ø 60 2xØ 40 mm Y union will be necessary and a slop of 15 must be kept. The two ventitation units must be equaly distant (X=3 m.) : X1 = X2 Pict..2 X1 X2 1 1 The two Blower Packs Equilibrage must be equally du réseau distant vapeur X, X1 soit = X2 X1=X2 Pict..3 3 meters mètres maxi. TAKE CARE : Attach hose on wall before connecting it to Blower Pack Steam distribution union Ø60mm - 2xØ40mm (code: DIV0019) Pict.4 Installation of the ventilation unit in a room different from where the humidifier is installed (Pict. 4). A Make sure that the length of the steam hose between the ventilation unit and the humidifier does not exceed 3 m. DETAIL A TAKE CARE : Attach hose on wall before connecting it to Blower Pack 5 Pictures for illustrating puposes only

6 Installation As far as the ElectroVap MC2 40 to 60 are concerned, a Ø 40 mm steam hose ensures the connection between the humidifier and the ventilation unit. DETAIL A In case an ElectroVap RTH-V2 60, you should use two Ø60-40 mm adaptors (s.a. Pict. 4). TAKE CARE : Attach hose on wall before connecting it to Blower Pack A Adaptateur Adaptor Ø O60/40mm 60/40 mm (code: : ) Pict. 4 Wall mounting On installation, use a L bracket & a set of screws (not supplied) suitable for the surface material where the blower pack should be hanged to. Please refer the under mentioned example (pict. 5. Blower Pack - Rear view Pict. 5 4 x Ø 8 mm hole 6 Pictures for illustrating puposes only

7 Installation Electrical wiring Blower Pack BP1 3 4 The electrical supply is made on terminals 3 & 4 on the Din rail of the steam humidifier s series CMC, MC2, RTH-LC and RTH-V2. Blower Pack BP2 3 4 IMPORTANT : For best performances, the humidifier menu «Configuration changing menu» must be preset for use with the Blower Pack. Dial access code , scroll menu up or down to get sub-menu TERMIN.3-4 (230V) and select «ROOM VENTIL». Validate the selection. (for version programme V2.21 and up) CHANGING CONFIGU- RATION MENU With the humidifier switched on, press the key and the first digit will flash. Press the (2) key to increase or (3) key to decrease the first figure to enter of the access code. Press (1) to confirm. The next digit will start to flash. Repeat for a second and third digit of the access code. DIAL ACCESS CODE: XXX ENTER ACCESS CODE: 152 TERMINALS 3-4 (230V) ROOM VENTIL. 7 Pictures for illustrating puposes only

8 LR Rue Feu St Eloi Ambrumesnil - France Export division : tel. +33 (0) ou +33 (0) fax. +33 (0) export@devatec.com - France division : tel fax. +33 (0) france@devatec.com - devatec reserves the right to change specifications or design of the equipment described in this brochure without prior notice. 8 Pictures for illustrating puposes only Blower Pack - Rev 2b edition

Technical handbook. Protective enclosure for outdoor applications. Pictures for illustrative purposes

Technical handbook. Protective enclosure for outdoor applications. Pictures for illustrative purposes Technical handbook Protective enclosure for outdoor applications Pictures for illustrative purposes Pictures for illustrative purposes 2 Contents What is in the box 4 Overall dimentions & weight 5 to 7

More information

TECHNICAL MANUAL BlowerPack fan unit

TECHNICAL MANUAL BlowerPack fan unit TECHNICAL MANUAL BlowerPack fan unit Summary 1 SAFETY INSTRUCTIONS 1.1 Introduction 1.2 Important notes 1.3 Declaration of conformity 1.4 RoHS Declaration 4 4 5 6 6 2 OVERVIEW 2.1 Characteristics 2.2

More information

CMC Electrode steam humidifier

CMC Electrode steam humidifier Technical manual R CMC Electrode steam humidifier For capacities from 1 to 4 kg/h 1 Pictures for illustating purposes only 2 Pictures for illustating purposes only Contents Safety information 4-5 Product

More information

User s manual. Pictures for illustra ve purposes only

User s manual. Pictures for illustra ve purposes only User s manual R R 3 30 / Pictures for illustra ve purposes only Contents Safety information 4-5 Product accreditation 6 Delivery contents 7 Dimensions & Weights 8 Humidifier component parts 9 Installation

More information

User manual. Resistive steam humidifier from 3 to 17 kg/h. Pictures for illustrative purposes only

User manual. Resistive steam humidifier from 3 to 17 kg/h. Pictures for illustrative purposes only User manual R Resistive steam humidifier from 3 to 7 kg/h Pictures for illustrative purposes only 2 Pictures for illustrative purposes only Contents Product accreditation 4 Safety information 5-6 Unit

More information

Electrode steam humidifier

Electrode steam humidifier Technical manual Electrode steam humidifier Pictures for illustrating purposes only Table of Contents Safety information 3-4 Accreditation 5 RoHS declaration 6 Delivery contents 7 Dimensions & weights

More information

Electrode steam humidifier

Electrode steam humidifier Technical manual Electrode steam humidifier For applications ranging from 5 to 99 kg//h Pictures for illustrating purposes only Table of Contents Safety information 3-4 Accreditation 5 RoHS declaration

More information

User manual. Resistive steam humidifier from 3 to 17 kg/h. Pictures for illustrative purposes only

User manual. Resistive steam humidifier from 3 to 17 kg/h. Pictures for illustrative purposes only User manual R Resistive steam humidifier from 3 to 7 kg/h Pictures for illustrative purposes only Contents Product accreditation 4 Safety information 5-6 Unit wall installation Dimensions 7 Wall mounting

More information

Technical manual. Steam generator for hammam. Pictures for illustrating purposes only

Technical manual. Steam generator for hammam. Pictures for illustrating purposes only Technical manual Steam generator for hammam Contents Safety information 3-4 Accreditation 5 RoHS declaration 6 Delivery contents 7 Dimensions & weights 8 Humidifier component part overview 9 Wall installation

More information

Electric Resistance Steam Humidifier. umidity Source Quality, Selection, Support

Electric Resistance Steam Humidifier. umidity Source Quality, Selection, Support Electric Resistance Steam Humidifier H umidity Source Quality, Selection, Support PERFORMANCE AND FEATURES - Full range : (11-220 lbs/hr) output - Works with any type of water - Microprocessor control

More information

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction Reducted footprint Dual-wall construction Built-in variable frequency drive PLC control Variable speed condenser fan Cooling capacity: 5 to 50 kw Air flow: 1 000 to 12 000 m 3 /h ErP READY Use Precision

More information

QUALITY STEAM. Electrode Steam Humidifier Condair EL. Humidification and evaporative cooling

QUALITY STEAM. Electrode Steam Humidifier Condair EL. Humidification and evaporative cooling QUALITY STEAM Electrode Steam Humidifier Condair EL Humidification and evaporative cooling Electrode steam humidifier Flexible steam distribution Condair RS for use in HVAC-Systems Condair EL with blower

More information

Key benefits. Why Condair CP3?

Key benefits. Why Condair CP3? Condair Cp3 Humidification The Electrode Steam Humidifier. Powerful and User-Friendly Why? Tailored technology. You can program your specifications exactly to the last kilogram with the CP3 Card. This

More information

Constant climate chambers

Constant climate chambers Constant climate chambers KBF 115 (E2) - Constant climate chamber The KBF series was particularly designed for absolutely reliable stability tests and precise maintenance of constant climatic conditions.

More information

Sun Ray Electric Radiators Stylish, Efficient, Low Energy

Sun Ray Electric Radiators Stylish, Efficient, Low Energy Sun Ray Electric Radiators Stylish, Efficient, Low Energy SAVING ENERGY REDUCING THE CARBON FOOTPRINT Wifi Issue 6 Ireland Edition SUN RAY ELECTRIC RADIATORS Head office and Energy Showrooms Celebrating

More information

Steam to Steam Humidifier

Steam to Steam Humidifier Steam to Steam Humidifier SKS4 Series READ AND SAVE THESE INSTRUCTIONS SKS4-CE-ESA-180820 Safety Steam or Hot Water (HTHW) Supply Electricity Health & Safety All work concerned with Steam or High Temperature

More information

Steam Humidification Light Commercial Applications. Better technology means better business.

Steam Humidification Light Commercial Applications. Better technology means better business. Steam Humidification Light Commercial Applications Better technology means better business. Aprilaire Steam Humidifiers are built to last. Through extensive research and over 50 years expertise in humidification

More information

Constant climate chambers

Constant climate chambers Constant climate chambers KBF P 240 (E2) - Constant climate chamber for photostability tests Specialized equipment for photostability tests. Integrated cooling of fans consistently compensates for the

More information

OptiSorp. Steam distribution system EN 1112

OptiSorp. Steam distribution system EN 1112 OptiSorp Steam distribution system Installation and operating instructions 1115766 EN 1112 Contents 1 Notes on steam distribution system OptiSorp 4 1.1 OptiSorp Steam distribution system for very short

More information

ALFÉA EXCELLIA DUO. more. less AIR TO WATER HEAT PUMP

ALFÉA EXCELLIA DUO. more. less AIR TO WATER HEAT PUMP AIR TO WATER HEAT PUMP ALFÉA EXCELLIA DUO Five models: 11 to 16 kw (single and -phase) Heating and domestic hot water integrated COP up to 4. Suitable for new build and renovation Integrated domestic hot

More information

Steam Injection. Humidification system

Steam Injection. Humidification system Steam Injection Humidification system Standard and CLEAN-STEEM TM models suitable for a wide range of applications DRI-STEEM s Steam Injection humidifiers use steam from an external source, such as an

More information

Humidifiers. Model 400/400M Humidifiers NO. BLUE/GRAY UNITS - PART NAME QTY/CTN PART NO. PART NO.

Humidifiers. Model 400/400M Humidifiers NO. BLUE/GRAY UNITS - PART NAME QTY/CTN PART NO. PART NO. Effective Date: January, 0 Humidifiers Model 00/00M Humidifiers B B B B B B Base (blue/gray) Cover (blue/gray) Automatic Digital Humidifier Control Name Plate (blue/gray) Hole Plug (blue/gray) MODEL 00

More information

KMF Environmental test chamber for constant climate

KMF Environmental test chamber for constant climate SHENZHEN YIHUAXIN ELECTRNICS C.,LTD Tel:+86-755-86218000 Fax:+86-755-86218111 www.yihuaxin.net yhx@yihuaxin.net Environmental test chambers KMF 240 - Environmental test chamber for constant climate The

More information

FINISHING EQUIPMENT NOVA-S-PLUS. Vacuum/blowing ironing table

FINISHING EQUIPMENT NOVA-S-PLUS. Vacuum/blowing ironing table FINISHING EQUIPMENT FINISHING EQUIPMENT 1 NOVA-S-PLUS Vacuum/blowing ironing table TECHNICAL DATA NOVA-S-Plus Vacuum motor 0,60 kw Motor for blowing 0,60 kw Board heating elements 1,2 kw Boiler heating

More information

GUF-100RDH3. Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the issued date.

GUF-100RDH3. Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the issued date. Issued July 2004 No. U-101 FRESH MASTER HAND BOOK (For HONG KONG) FOR DEALERS Model: GUF-50RDH3 GUF-100RDH3 Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the

More information

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY >OLYL >H]LSLUN[O 4H[[LYZ SMOKELESS FLARE MONITOR Smokeless Flare Monitor (FM) Smokeless flares incinerate flammable hazardous

More information

Package Hygienic Air Handling Units. PHK Series

Package Hygienic Air Handling Units. PHK Series Package Hygienic Air Handling Units PHK Series 1 PHK Series PHK : Standard PHK HP : Heat Pump PHK TO : Clean Room Air Handling Unit Up to 11.000 m 3 /h Airflow Complying with DiN 1946/4 Hygiene Criteria

More information

PRODUCT BULLETIN. Rev. A Monitoring Station offering PN Rev. B as a direct replacement. OVERVIEW / DESCRIPTION

PRODUCT BULLETIN. Rev. A Monitoring Station offering PN Rev. B as a direct replacement. OVERVIEW / DESCRIPTION PRODUCT BULLETIN ISSUE/DATE: March 28, 2008 rev A BULLETIN NUMBER: AQ032808 SUBJECT: Monitoring Station PRODUCT LINE: Aquafine UV Equipment TOPIC: REVISION TO THE 41114-1 MONITORING STATION OVERVIEW /

More information

Steam to Steam Humidifier

Steam to Steam Humidifier Steam to Steam Humidifier SKS4 Series 4011008 READ AND SAVE THESE INSTRUCTIONS SKS4-ESL-181116 Safety Steam Supply Electricity Health & Safety All work concerned with steam supply installation MUST only

More information

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1

HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1 HyBo - Hydraulic Interface Unit AMBIENT HEATING AND DOMESTIC HOT WATER PRODUCTION FOR CENTRAL HEATING SYSTEM UNIT CODE EHIU1 INSTALLATION, COMMISSIONING AND OPERATING INSTRUCTIONS Contents Unit as delivered

More information

RHP120 RHP300 Steam Boiler Series

RHP120 RHP300 Steam Boiler Series Electra Steam, Inc. Phone: 540-662-3811 4407 Martinsburg Pike Fax: 540-665-8101 Clear Brook, VA 22624 email: Sales@reimersinc.com USA web: www.reimersinc.com HEATING POWER kw RHP120 RHP300 Steam Boiler

More information

Granule Gastro/Combi

Granule Gastro/Combi Granule Gastro/Combi Spare parts list Granule Gastro serial # 710010- Granule Combi serial # 810010- Art. No. EN 21111-2010-03. GRANULDISK AB retains the right to make technical changes to the products.

More information

Vapor-logic 3 to Vapor-logic4

Vapor-logic 3 to Vapor-logic4 Vapor-logic 3 to Vapor-logic4 Adaptor Board Installation Manual Warnings and c autions Warnings and cautions WARNING Indicates a hazardous situation that could result in death or serious injury if instructions

More information

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation Extensive range of chilled water or direct expansion systems Compact and attractive design Energy savings with EC motor and self-regulating control Easy to install Cooling capacity: 10 to 116 k Air flow

More information

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment: Constant climate chambers KBF 240 (E5.2) - Constant climate chamber The KBF series was particularly designed for absolutely reliable stability tests and precise maintenance of constant climatic conditions.

More information

Condensate removal pumps

Condensate removal pumps Condensate removal pumps World Premiere SICCOM S.A.S was founded in 1979 and specialises in level and proximity sensors, bimetal heat protection and condensate removal pumps. SICCOM's expertise means customers

More information

LE Series. Electrode Steam Humidifiers

LE Series. Electrode Steam Humidifiers LE Series Electrode Steam Humidifiers Electrode Steam Humidifiers The Company For over 35 years, Vapac has been designing, manufacturing and specializing in high quality solutions for indoor air humidification

More information

FlexLine. Air humidification for industry, commerce, culture and leisure. Steam humidifier. New flexibility in award-winning quality

FlexLine. Air humidification for industry, commerce, culture and leisure. Steam humidifier. New flexibility in award-winning quality FlexLine Steam humidifier New flexibility in award-winning quality A series of units with a wide performance range for every area of application Individual confi guration Easy operation Highest quality

More information

ComfortNet CTK04 Featuring the RedLINK Suite of Home Comfort Solutions

ComfortNet CTK04 Featuring the RedLINK Suite of Home Comfort Solutions ComfortNet CTK04 Featuring the RedLINK Suite of Home Comfort Solutions Agenda Comfort Advantage System Configurations Installing ComfortNet ComfortNet Control Set up Dehumidification and Defrost Settings

More information

USER GUIDE: COLOR TOUCHSCREEN COMMUNICATING WITH HUMIDITY CONTROL THERMOSTAT. Outside Temperature (if installed) Room Temperature.

USER GUIDE: COLOR TOUCHSCREEN COMMUNICATING WITH HUMIDITY CONTROL THERMOSTAT. Outside Temperature (if installed) Room Temperature. User Guide: Color Touchscreen Communicating with Humidity Control Thermostat TPCC32U01 USER GUIDE: COLOR TOUCHSCREEN COMMUNICATING WITH HUMIDITY CONTROL THERMOSTAT Adjusting Temperature (Temporary Override

More information

Gas fired rooftops. Comfort all year round

Gas fired rooftops. Comfort all year round Gas fired rooftops Comfort all year round Gas fired rooftops YCD/YCH 060-075-085-100- 120-150-175-200-250 Cooling capacity 18 to 68 kw Gas heating modules : G205-G250-G350-G400- marked Voyager rooftops

More information

Quatro canal Super-powered climate control for 4-pipe systems

Quatro canal Super-powered climate control for 4-pipe systems Quatro canal Super-powered climate control for 4-pipe systems Heating, cooling, ventilation. Despite its compact dimensions, the Quatro Canal is a powerful main heating system, cooling unit and ventilation

More information

WATER BOILERS CB(W), WKI, WKT, WKS

WATER BOILERS CB(W), WKI, WKT, WKS WATER BOILERS CB(W), WKI, WKT, WKS Water boilers for professionals During the interval at the theatre and during meetings, after a sport match and at work large or small volumes of hot water are needed

More information

PELLET MILL. construction s prescriptions and safety. Besides, Nova Pellet S.r.l. has obtained in 2007 the Italian

PELLET MILL. construction s prescriptions and safety. Besides, Nova Pellet S.r.l. has obtained in 2007 the Italian PELLET MILL N-MIDI pellet mill machine is projected and manufactured in accordance with CE norm about construction s prescriptions and safety. Besides, Nova Pellet S.r.l. has obtained in 2007 the Italian

More information

Evap WTW INSTALLATION INSTRUCTIONS D

Evap WTW INSTALLATION INSTRUCTIONS D Evap WTW INSTALLATION INSTRUCTIONS (English) WWW.BRINKAIRFORLIFE.NL 614796-D English (EN) Installation instructions Humidifier for central ventilation with heat recovery KEEP WITH THE PRODUCT This product

More information

VT Series. Service Kit Manual CAUTION

VT Series. Service Kit Manual CAUTION VT Series Electric Humidifier Service Kit Manual WARNING Indicates a hazardous situation that could result in death or serious injury if instructions are not followed. CAUTION Indicates a hazardous situation

More information

INSTALLATION & USER MANUAL

INSTALLATION & USER MANUAL INSTALLATION & USER MANUAL HC Digital Automatic Humidistat (Y3760) CONTROLS 506808-01 3/2016 Supersedes 6/2011 picture goes here THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE NOTICE

More information

USER S INFORMATION MANUAL

USER S INFORMATION MANUAL USER S INFORMATION MANUAL PREMIUM HIGH DEFINITION TOUCH SCREEN COMMUNICATING CONTROL MODELS: S1-TTSCC01 Energy Saver ABOUT YOUR COMMUNICATING CONTROL.......................... 2 Features.........................

More information

Shower Thermostatic Mixer Fitting Instructions

Shower Thermostatic Mixer Fitting Instructions Shower Thermostatic Mixer Fitting Instructions Thank you for selecting this product. We have taken great care to ensure that this product reaches you in perfect condition. However should any parts be damaged

More information

VAPORSTREAM. Electric-to-Steam Humidifier. With Vapor-logic controller Web-enabled access I nteroperability via Modbus or optional BACnet or LonTalk

VAPORSTREAM. Electric-to-Steam Humidifier. With Vapor-logic controller Web-enabled access I nteroperability via Modbus or optional BACnet or LonTalk VAPORSTREAM Electric-to-Steam Humidifier With Vapor-logic controller Web-enabled access I nteroperability via Modbus or optional BACnet or LonTalk High-performance humidification dristeem offers a complete

More information

INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS For the UH-301 and UH-303 Ultrasonic Humidifiers HUMIDITY SOURCE LLC 30 Garden Ct. S.Garfield, NJ 07026 USA humiditysource@aol.com Phone: 973-916-1001

More information

R 407 C. > in industrial application. Always very much appreciated for special installations these units shown their powers :

R 407 C. > in industrial application. Always very much appreciated for special installations these units shown their powers : SINGLEPACKAGE CONSOLE UNITS, MONOSPLIT, AIR CONDENSING UNITS APPLICATIONS COMMERCIAL SECTOR CONSOLE UNITS AIR CONDENSING UNITS Always very much appreciated for special installations these units shown their

More information

Hydro Swaging Machines Brochure

Hydro Swaging Machines Brochure Hydraulic & Offshore Supplies Hydro Swaging Machines Brochure YOUR GATEWAY TO GLOBAL SUPPLY HOSE ASSEMBLIES PRESSURE TESTING WALFORM EQUIPMENT PACKAGES FLANGES PIPE & TUBE SM 625 25-08 8 11 40 25-11 11-14

More information

Humidifiers Dealer Parts List Model 400/400M Humidifiers

Humidifiers Dealer Parts List Model 400/400M Humidifiers Effective Date: September 1, 2012 Humidifiers Dealer Parts List Model 400/400M Humidifiers MODEL 400 MODEL 400M NO. BLUE/GRAY UNITS - PART NAME QTY/CTN PART NO. PART NO. 4B Base (blue/gray) 1 4734 4734

More information

Constant climate chamber with humidity

Constant climate chamber with humidity KBF series (E5.2) Constant climate chambers Constant climate chamber with humidity The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climate

More information

Constant climate chambers

Constant climate chambers KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.

More information

ElEctronIc 2 DIal tap timer co1701 InstructIon Manual

ElEctronIc 2 DIal tap timer co1701 InstructIon Manual Electronic 2 DIAL Tap timer CO1701 Instruction Manual CO1701 2 Dial Tap Timer.indd 1 Table of Contents Technical Data... p1 Glossary... p2 Applications & Safety Instructions... p3 Connecting to the Tap

More information

Plant growth chambers

Plant growth chambers Plant growth chambers KBWF 240 (E5.1) - Plant growth chamber with optimal climatic conditions The closest thing to natural conditions. Making use of the multifaceted programming options, we achieve perfect

More information

Industrial vacuum cleaners ATTIX 30

Industrial vacuum cleaners ATTIX 30 Easy handling and easy maintenance PRODUCT FACTS ATTIX 30 represents a new possibility of achieving superior suction power in a compact and flexible solution. Silent, small and mobile, but with the same

More information

Product data sheet AIRWIN additional modules Accessories AIRWIN

Product data sheet AIRWIN additional modules Accessories AIRWIN Product data sheet AIRWIN additional modules Ozone module Item no. 2002004 Hygiene fresh produce humidification UB-12/18/24 Fan module KMB Item no. 2002003 Airflow AquaDrain module Item no. 2002001 Hygiene

More information

Constant climate chambers

Constant climate chambers KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.

More information

VarioVac vacuum regulators Consumables and Accessories

VarioVac vacuum regulators Consumables and Accessories VarioVac vacuum regulators Consumables and Accessories Easy to use excellence. Accurate and infinitely variable vacuum regulation, top-quality manometers, ease of operation and great versatility the VarioVac

More information

New Generation KBF 240 series

New Generation KBF 240 series Constant climate chambers New Generation 240 series The constant climate chamber is the expert for absolutely reliable stability tests and precise maintenance of constant climatic conditions. With its

More information

Low Level Thermal Electric Radiator. Installation and Operation Guide. Models. Type Wattage No. of Fins Size (HxWxD) (mm) Net Weight (kg)

Low Level Thermal Electric Radiator. Installation and Operation Guide. Models. Type Wattage No. of Fins Size (HxWxD) (mm) Net Weight (kg) 20160425 Sun Ray Neptune Low Level Thermal Electric Radiator Installation and Operation Guide Models Type Wattage No. of Fins Size (HxWxD) (mm) Net Weight (kg) LR950 950w 10 340x865x96 12.8 LR1425 1425w

More information

High spin hygienic barrier washer-extractors

High spin hygienic barrier washer-extractors High spin hygienic barrier washer-extractors IB265 - IB332 - IB442 - IB663 Features Stainless steel body and grey painted side legs Freestanding, high spin Oversized frame, bearings and drum Large drain

More information

DR 25 DR 35 DR 55 DR 80 DR 120 DR 170 DR 335

DR 25 DR 35 DR 55 DR 80 DR 120 DR 170 DR 335 DR 25 DR 35 DR 55 DR 80 DR 120 DR 170 DR 335 I N D U S T R I A L T U M B L E D R Y E R S DR 25 - DR 35 - DR 335 - DR 55 - DR 80 Stainless steel drum standard high quality Large stainless steel door Easy

More information

Constant climate chambers

Constant climate chambers Constant climate chambers KBF ICH series Environmental simulation chambers for constant climatic conditions with light As regards compliance with standards, performance and functionality, the characteristics

More information

ARRANGING FOR THE ROOM. Arranging the room for installation. Turkish Bath. Release n 3, November 2010

ARRANGING FOR THE ROOM. Arranging the room for installation. Turkish Bath. Release n 3, November 2010 GB Arranging the room for installation Turkish Bath Release n 3, November 2010 ARRANGING THE ROOM FOR INSTALLATION THE ROOM The room where the "" is installed shall have a 2,40m. minum height and be sufficiently

More information

User Guide: *IG1605EW*

User Guide: *IG1605EW* User Guide: IntelliZone2 MasterStat System Communicating with Humidity Control Thermostat USER GUIDE: INTELLIZONE2 MASTERSTAT COMMUNICATING THERMOSTAT Adjusting Temperature (Temporary Override in Programmable

More information

INSTALLATION AND INITIAL OPERATING INSTRUCTIONS

INSTALLATION AND INITIAL OPERATING INSTRUCTIONS Professional kitchens INSTALLATION AND INITIAL OPERATING INSTRUCTIONS ELRO stationary kettle with integrated mixer Model JRW 2200 ELRO-WERKE AG Date: 07.09.11 checked: Initials: Document No: Register:

More information

"ER" Series Electric Humidifier

ER Series Electric Humidifier ER-1 Standard Water "ER" Series Electric Humidifier The Electric Humidifier from PURE Humidifier Co. is loaded with features and options. All you need is tap water, electricity, and a sanitary drain the

More information

XT SERIES. Electrode Steam Humidifiers. Easy to maintain Adaptable Comprehensive control with Vapor-logic option

XT SERIES. Electrode Steam Humidifiers. Easy to maintain Adaptable Comprehensive control with Vapor-logic option XT SERIES Electrode Steam Humidifiers Easy to maintain Adaptable Comprehensive control with Vapor-logic option Cost-effective steam humidification XT Series electrode steam humidifiers from DriSteem provide

More information

Defensor Mk5. Resistive Humidifiers. Technical Documentation EN 0904

Defensor Mk5. Resistive Humidifiers. Technical Documentation EN 0904 Defensor Mk5 Resistive Humidifiers Technical Documentation 1115661 EN 0904 Contents 1 Introduction 4 1.1 To the very beginning 4 1.2 Notes on the technical documentation 4 2 For your safety 5 3 Product

More information

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

DBS721, DBS729 Sounder interbase, Sounder beacon interbase DBS721, DBS729 Sounder interbase, Sounder beacon interbase For the automatic addressable detector bus C-NET Cerberus PRO Sounder interbase DBS721 and sounder beacon interbase DBS729 11 selectable tones,

More information

Operating Instructions READ AND SAVE THESE INSTRUCTIONS

Operating Instructions READ AND SAVE THESE INSTRUCTIONS Operating Instructions READ AND SAVE THESE INSTRUCTIONS Aprilaire Communicating Thermostat Model 8870 CAUTION: Do not set to OFF mode during periods when freezing temperatures could occur. Thank you for

More information

I EN 1811 INSTALLATION MANUAL. Steam humidifier Condair EL. Humidification and Evaporative Cooling

I EN 1811 INSTALLATION MANUAL. Steam humidifier Condair EL. Humidification and Evaporative Cooling 2582485-I EN 1811 INSTALLATION MANUAL Steam humidifier Condair EL Humidification and Evaporative Cooling Thank you for choosing Condair Installation date (MM/DD/YYYY): Commissioning date (MM/DD/YYYY):

More information

USER GUIDE EXPLOSION-PROOF TELEPHONES ATEX GASES AND DUSTS TYPE 227A1 IM2 FOR GROUP I MINING II 2GD FOR GROUP IIC AND IIIC GASES AND DUSTS

USER GUIDE EXPLOSION-PROOF TELEPHONES ATEX GASES AND DUSTS TYPE 227A1 IM2 FOR GROUP I MINING II 2GD FOR GROUP IIC AND IIIC GASES AND DUSTS USER GUIDE EXPLOSION-PROOF TELEPHONES ATEX GASES AND DUSTS TYPE 227A1 IM2 FOR GROUP I MINING OR II 2GD FOR GROUP IIC AND IIIC GASES AND DUSTS Comprehensive guide available on our website: www.lelas.fr

More information

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE Page 1 / 5 MARINE DIVISION 67/71 Boulevard du Château 92200 Neuilly-sur-Seine - France Tel. 33 1 55 24 70 00 Fax. 33 1 55 24 70 45 www.veristar.com Certificate number: 05093/D2 BV File number : ACE 02/008/31

More information

humifog Pressurized water humidifi ers

humifog Pressurized water humidifi ers humifog Pressurized water humidifi ers T e c h n o l o g y & E v o l u t i o n humifog for ducts and AHUs humifog represents the latest generation of atomising humidifi ers with a power consumption of

More information

Constant climate chambers

Constant climate chambers KBF series (E5.2) Constant climate chambers Constant climate chambers The BINDER KBF is the specialist for unconditionally reliable stability testing and precise maintenance of constant climatic conditions.

More information

Steam/HTHW to Steam Humidifier SKS Series

Steam/HTHW to Steam Humidifier SKS Series Steam/HTHW to Steam Humidifier SKS Series 4011008 READ AND SAVE THESE INSTRUCTIONS SKS-CE-IOM-181002 Safety HOT WATER (HTHW) OR STEAM SUPPLY! All work concerned with High Temperature Hot Water (HTHW) supply

More information

GTS. User Manual. Gas-to-Steam Humidifier. Affix product label here.

GTS. User Manual. Gas-to-Steam Humidifier. Affix product label here. Following installation of this steam-generating humidifier, the installer shall instruct the user in the operation of the steam-generating humidifier and the safety devices. The installer shall give at

More information

for the Programmable Humidifier Automatic Flushing Timer

for the Programmable Humidifier Automatic Flushing Timer INSTALLATION INSTRUCTIONS for the Programmable Humidifier Automatic Flushing Timer The Humidifier Automatic Flushing Timer automatically flushes accumulated mineral deposits from all central-system steam

More information

Constant climate chamber with ICH-compliant illumination

Constant climate chamber with ICH-compliant illumination KBF P series (E5.2) Constant climate chambers Constant climate chamber with ICH-compliant illumination The BINDER KBF P constant climate chamber, equipped with ICH-compliant illumination, is the expert

More information

LevControl LC PLUS OPERATING INSTRUCTIONS ALL OUR SYSTEMS COMPLY WITH DIRECTIVE 73/23 EEC - 89/336. Cod /0-12/97

LevControl LC PLUS OPERATING INSTRUCTIONS ALL OUR SYSTEMS COMPLY WITH DIRECTIVE 73/23 EEC - 89/336. Cod /0-12/97 LevControl LC PLUS ALL OUR SYSTEMS COMPLY WITH DIRECTIVE 73/23 EEC - 89/336 OPERATING INSTRUCTIONS Cod. 71503277/0-12/97 WARNING!!! THE OPERATIONS LISTED BELOW AND THOSE MARKED BY THIS SYMBOL ARE STRICTLY

More information

Humidifiers Dealer Parts List

Humidifiers Dealer Parts List Effective Date: July, 204 Revised Date: March 20, 205 Humidifiers Dealer Parts List Model 400/400M Humidifiers 6A 6B MODEL 400 MODEL 400M NO. BLUE/GRAY UNITS - PART NAME QTY/CTN PART NO. PART NO. 4B Base

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Loop Alarm Model SC1290 and SCL1290 INSTALLATION INSTRUCTIONS LOVE LOVE CONTROLS a Division of Dwyer Instruments, Incorporated PO Box 338 Michigan City, IN 46361-0338 (800) 828-4588 (219) 879-8000 FAX

More information

Constant climate chambers

Constant climate chambers Constant climate chambers KBF series Environmental simulation chambers for constant climatic conditions The KBF series was particularly designed for absolutely reliable stability tests and precise maintenance

More information

SENTINEL D - Fault Passage Monitoring

SENTINEL D - Fault Passage Monitoring SENTINEL D - Fault Passage Monitoring DIRECTIONAL FAULT PASSAGE INDICATORS FOR OVERHEAD MV NETWORKS Installed on poles of overhead lines, the Overhead-Sentinel-D range allows locating the fault arisen

More information

XT SERIES. Electrode Steam Humidifiers. Easy to maintain Adaptable Comprehensive control with Vapor-logic option

XT SERIES. Electrode Steam Humidifiers. Easy to maintain Adaptable Comprehensive control with Vapor-logic option XT SERIES Electrode Steam Humidifiers Easy to maintain Adaptable Comprehensive control with Vapor-logic option Cost-effective steam humidification Model XTP XT Series electrode steam humidifiers from DriSteem

More information

FlexLine. Air humidification for industry, commerce, culture and leisure. Steam humidifier. New flexibility in proven quality

FlexLine. Air humidification for industry, commerce, culture and leisure. Steam humidifier. New flexibility in proven quality FlexLine Steam humidifier New flexibility in proven quality A series of units for all applications and performance categories Individual confi guration Easy operation Highest quality and energy effi ciency

More information

Industrial vacuum cleaners AERO 26. Compact wet&dry vacuum cleaner with filter cleaning and ergonomic design

Industrial vacuum cleaners AERO 26. Compact wet&dry vacuum cleaner with filter cleaning and ergonomic design Being compact, light-weight and robust, the AERO wet and dry vacuum cleaner can easily be transported to any location, e.g. by car. After finishing your job, the container can nice and easily be emptied

More information

Steam Humidifier Fan Pack Installation & Maintenance Instructions

Steam Humidifier Fan Pack Installation & Maintenance Instructions 850 Steam Humidifier Fan Pack 5658 Fan Pack Service Part Steam Humidifier Fan Pack Installation & Maintenance Instructions TABLE OF CONTENTS Safety Cautions...2 Materials List...3 Operation...3 Specifications

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Loop Alarm Model SC1490 and SCL1490 INSTALLATION INSTRUCTIONS LOVE LOVE CONTROLS a Division of Dwyer Instruments, Incorporated PO Box 338 Michigan City, IN 46361-0338 (800) 828-4588 (219) 879-8000 FAX

More information

XTR. Electrode Steam Humidifier

XTR. Electrode Steam Humidifier XTR Electrode Steam Humidifier Easy to operate E asy to maintain just replace the cylinder Affordable to buy, economical to operate D isperse steam into ductwork or open spaces Humidify for health and

More information

Sterilizers N e w G e n e r a t i o n

Sterilizers N e w G e n e r a t i o n Sterilizers N e w G e n e r a t i o n New Lisa 500 and 300 series, the arrival of a new concept Lisa 500 and 300 sterilizers provide «medical grade sterilization» in your dental practice for total security.

More information

Transfer Printer BP-PR PLUS series. Spare Parts List Edition 7/06

Transfer Printer BP-PR PLUS series. Spare Parts List Edition 7/06 Transfer Printer BP-PR PLUS series Spare Parts List Edition 7/06 Information on the scope of delivery, appearance, performance, dimensions and weight reflect our knowledge at the time of printing. We reserve

More information

PELLET MILL. developed properly for pellet production and all technologies and mechanical solutions are chosen to

PELLET MILL. developed properly for pellet production and all technologies and mechanical solutions are chosen to PELLET MILL N-ECO pellet mill machine is projected and manufactured in accordance with CE norm about construction s prescriptions and safety. With N-ECO you will save money and get lower pellet production

More information

Glass and Dishwashers AMX / AUX Series

Glass and Dishwashers AMX / AUX Series Glass and Dishwashers AMX / AUX Series INSTALLATION OPERATION REV. 8.xx 04.07.2005 Installation and Operation Instructions for Models of AMX / AUX Series Content Page 1 Installation... 3 2 Connections...

More information

HIGH EFFICIENCY THRU WALL SELF CONTAINED HEATING and COOLING UNITS napoleonheatingandcooling.com

HIGH EFFICIENCY THRU WALL SELF CONTAINED HEATING and COOLING UNITS napoleonheatingandcooling.com HIGH EFFICIENCY THRU WALL SELF CONTAINED HEATING and COOLING UNITS napoleonheatingandcooling.com ARCHITECTURALLY INSPIRED. We ve reinvented high efficiency. Designed for conventional thru wall installation

More information