Product Guide & Price List

Size: px
Start display at page:

Download "Product Guide & Price List"

Transcription

1 the heater people Product Guide & Price List Valid from 1st November 2018 specialists in Commercial and industrial heaters Underfloor heating and Heating cables 2019

2 Typical heating GARDENS & PATIOS STORE ENTRANCES COMMUNITY HALLS Patio heaters - page 54 OFFICES Air Curtains - page 38 WAREHOUSES Radiant cassettes - page 63 PACKING AREAS Ceiling panels - page 66 Industrial fan heaters - page 40 Halogen heaters - page 58

3 applications SHOPS CHURCHES System X - page 26 Pew heaters - page 44 DINING AREAS WATER TREATMENT PLANTS 'All Black' radiant heaters - page 52 HAZARDOUS AREAS ATEX tubular heaters - page 48 Industrial tubular heaters - page 46 WE CAN HELP SELECT THE RIGHT HEATER FOR AN APPLICATION CALL US TO DISCUSS YOUR NEXT HEATING PROJECT

4 Commercial and Industrial, Electric Heaters and Controls Catalogue and Price List Valid from 1st November 2018 Underfloor Heating Mirror Demisters Heating Cables & Freeze Protection M Series Underfloor Heating Mats 6-7 EHC Underfloor Heating Cables 8-9 F Series Underfloor Foil Mats IHC In-Screed Heating Cables CONTROLS Underfloor Heating Controls MD Mirror Demister Pads 13 CRJ Self Regulating Heat Cable for Pipes PW Pipe Freeze Protection Kit 20 WM Hot Water Maintenance Cable 21 S Series Snow and Ice Melting Heating Mats 22 GP Gutter and Downpipe Heating Cable 23 Underfloor Heating and Heating Cables Fan Assisted Heaters Convection Heaters Radiant Heaters Controls SYSTEM X The Flexible Fan Heating System SCHG Suspended Ceiling Heaters SMH Surface Mount Ceiling Heaters Series Overdoor / High Level Heaters RH Recessed Ceiling Heaters CA Commercial Air Curtains HCA High Capacity Air Curtains OUH Industrial Unit Heaters DSU Destratification Units 43 PH Pew Heaters SWD Industrial Tubular Heaters TX Explosion-Proof Tubular Heaters BLS 110V Convector 50 ETH 'All Black' Radiant Heaters HWP Patio Heaters CM Heated Chandelier 57 HN Halogen Heaters MC1 Halogen Heater Control Box ESP Radiant Cassettes RP Radiant Ceiling Panels CH Ceramic Heaters RL Replacement Halogen Lamps 70 CONTROLS Specifications: Thermostats Timers 78 Switches System X 82 Commercial and Industrial Heaters and Controls Case Studies CASE STUDIES Case Studies web sales@bnthermic.co.uk tel fax

5 Underfloor Heating and Heating Cables Underfloor Heating and Heating Cables web tel fax

6 M Series Heating Mats Standard Output Mats (150W/m²) Suitable as a main source of heating in most rooms UNDERFLOOR HEATING An economic means of heating a room and providing a luxurious warm floor Manufactured to the highest quality and backed by a Lifetime Warranty Application Suitable for any room including conservatories, bathrooms and wet rooms Ideal for use with a wide variety of floor surfaces including ceramic tiles, porcelain tiles, marble, slate, stone, carpet, vinyl, engineered wood and laminate flooring. Features Twin core cable assembled onto fibre glass web 3m power lead Continuous earth protection foil Continuous double sided fixing tape M Series: heat up to 16m² with a single mat Model Heated Area (m²) Mat Size (m) kw List Price M x M x M x M x M x M x M x M x M x M x M x M x M x M x M x M x M x M x M x High Output Mats (200W/m²) Recommended for Conservatories Model Heated Area (m²) Mat Size (m) kw List Price M x M x M x M x M x M x M x M x M x M x M x web sales@bnthermic.co.uk tel fax

7 Low Output Mats (100W/m²) Recommended for well insulated properties Model Heated Area (m²) Mat Size (m) kw List Price M x M x M x M x M x M x M x M x M x M x M x M x Mat Installation M Series heating mats can be installed in flexible selflevelling compound or directly into tile adhesive. When using with carpet, vinyl, engineered wood or laminate flooring the lowest tog underlay should be selected. If there is any doubt about the suitability of a floor surface for use with underfloor heating, confirmation should be sought from the flooring supplier. Selection Typical M Series Installation Mat cut here LIFETIME WARRANTY NEXT DAY DELIVERY FREE DESIGN SERVICE Kitchen Cabinet Mat cut here UNDERFLOOR HEATING The objective is to cover as high a percentage of the free floor area as possible. Mats should not be installed under fixtures such as kitchen cabinets and shower trays. As a rule of thumb, select a mat covering an area approximately 10% smaller than the free floor area. In larger rooms, it is common practice to use two or more mats. Generally, the mats are connected in parallel and controlled by a single thermostat. Insulation Boards Limits downward heat loss Model Dimensions (mm) Area Covered (m²) List Price F-Board x 600 x F-Board x 600 x Cold lead Electrical connection + thermostat Mat cut here Repair Kit Model Description List Price EHM-R-Kit Cable Repair Kit (emergency use) F-Board-6 and -10 Emergency Repair Kit FOR THERMOSTATS - See PAGE 14 web sales@bnthermic.co.uk tel fax

8 EHC Heating Cables UNDERFLOOR HEATING An economic means of heating a room and providing a luxurious warm floor Ideally suited to small and irregularly shaped rooms Manufactured to the highest quality and backed by a Lifetime Warranty Applications Suitable for any room including conservatories, bathrooms and wet rooms Ideal for use with a wide variety of floor surfaces including ceramic tiles, porcelain tiles, marble, stone, carpet, vinyl, engineered wood and laminate flooring. Features Twin core cable supplied with high adhesion tape 3m power lead Continuous earth protection foil Heat Cables Model kw Heated Area (m²) Cable Length (m) List Price EHC EHC EHC EHC EHC EHC EHC EHC EHC EHC EHC EHC EHC EHC Insulation Boards - Limits downward heat loss Model Dimensions (mm) Area Covered (m²) List Price F-Board x 600 x F-Board x 600 x web sales@bnthermic.co.uk tel +44 (0) fax +44 (0)

9 Tiles Tile adhesive Typical EHC Installation Fixing tape Repair Kit EHC Heating cable Subfloor F-Board Insulation (optional) Model Description List Price EHM-R-Kit Cable repair kit (emergency use) UNDERFLOOR HEATING Cable Installation EHC heating cables can be installed in flexible self-levelling compound or directly into tile adhesive. When using with carpet, vinyl, engineered wood or laminate flooring the lowest tog underlay should be selected. If there is any doubt about the suitability of a floor surface for use with underfloor heating, confirmation should be sought from the flooring supplier. F-Board-6 and -10 Electrical connections + thermostat Cold lead Emergency Repair Kit Selection The objective is to cover as high a percentage of the free floor area as possible. Cables should not be installed under fixtures such as kitchen cabinets and shower trays. In larger rooms, it is common practice to use two or more cables. Generally, the cables are connected in parallel and controlled by a single thermostat. An EHC heating cable installed in a bathroom FOR THERMOSTATS - See PAGE 14 web sales@bnthermic.co.uk tel fax

10 F Series Foil Heating Mats for laminate and engineered wood floors UNDERFLOOR HEATING An economic means of heating a room and providing a luxurious warm floor Manufactured to the highest quality and backed by a 10 Year Warranty Installed without adhesives or compounds Applications Suitable for any room including bathrooms Specifically designed for laminate or engineered wood floors 10 Features Heating cables sandwiched between 2 layers of aluminium ensuring excellent heat distribution Can be manipulated to fill a space just like a conventional heating mat Low profile (2mm approximate) keeps floor build-up to a minimum 3m power lead F Series Foil Heating Mats Model Heated Area (m²) Mat Size (m) kw List Price F x F x F x F x F x F x F x F x F x F x F x F x F x F Series foil heating mat specifically designed for laminate and engineered wood floors Insulation and Fixing Tape Model Description Area Covered List Price (m²) I-Pack-6 Pack of 19 sheets of I-Board-6 insulation/underlay 6mm thick I-Board-6 Individual sheet insulation/underlay 6mm thick LHT Fixing tape for I-Board AL-50 Fixing tape for F Series mat web sales@bnthermic.co.uk tel fax

11 Mat Installation F Series mats should be installed directly below laminate or engineered wood flooring and held in place with aluminium tape. The mats should be installed on top of a layer of I-Board-6 insulation/underlay which should be held in place with LHT high adhesion tape. A low profile F Series Installation Laminate or engineered wood flooring F Series Foil Heating Mat Selection I-Board-6 Insulation/underlay Subfloor The objective is to cover as high a percentage of the free floor area as possible. Mats should not be installed under fixtures such as kitchen cabinets and shower trays. As a rule of thumb, select a mat covering an area approximately 10% smaller than the free floor area. In larger rooms, it is common practice to use two or more mats. Generally, the mats are connected in parallel and controlled by a single thermostat. UNDERFLOOR HEATING Typical F Series Installation in a bathroom Externally mounted thermostat Cold Lead Cut mat here Cut mat here Cut mat here BATH Cut mat here Cut mat here SHOWER TRAY FOR THERMOSTATS - See PAGE 14 I-Board-6 LHT High Adhesive Tape AL-50 Aluminium Tape web sales@bnthermic.co.uk tel fax

12 IHC In-Screed Heating Cable UNDERFLOOR HEATING A more robust heating cable suitable for installation in a concrete screed Manufactured to the highest quality and backed by a 10 year warranty Applications Suitable for any type of room and both domestic and commercial installations Specifically designed for installation in a concrete screed Can be used with a wide variety of floor surfaces Features Twin core cable 3m power lead Continuous earth protection Held in place with metal fixing strips 10 Drum of IHC in-screed cable with IHC-F fixing strip In Screed Heating Cables Model kw Cable length (m) Area Covered 100W/m² Area Covered 150W/m² Area Covered 175W/m² List Price IHC IHC IHC IHC IHC IHC IHC IHC IHC IHC IHC IHC IHC IHC IHC-F Metal fixing strip (10m) typically one strip is required for every 8m² of heated area Cable Selection The objective is to cover as high a percentage of the free floor area as possible. Cables should not be installed under fixtures such as kitchen cabinets and shower trays. In larger rooms, it is common practice to use two or more cables which are usually connected in parallel and controlled by a single thermostat. Typically, we suggest a watt density between 150W/m² and 175W/m² however lower densities are often used in well insulated properties Cable Installation IHC cables are installed on a layer of insulation using IHC-F fixing strip. The cable should be arranged in evenly spaced loops and covered in 80mm to 100mm of concrete screed. IHC cables can be used with a wide variety of floor surfaces. If there is any doubt about the suitability of the suitability of a floor surface for use with underfloor heating, FOR THERMOSTATS - See PAGE 14 confirmation should be sought from the flooring supplier. 12 web sales@bnthermic.co.uk tel fax

13 MD Mirror Demister Pads MD-50 50W Demister pad with a typical running cost of 5 pence per week MIRROR DEMISTERS Providing a mist free mirror 100% effective in little over 2 minutes Very low energy consumption Simply integrated into the lighting circuit ensuring that they are not left running Features Protects an area approximately 20% larger than the pad itself Double insulated and completely sealed for total safety Less than 1mm thick Peel off adhesive backing 1m long power lead Peel-off adhesive backing BESPOKE SIZES AVAILABLE Selection PLEASE CALL US FOR PRICE AND DELIVERY MD Mirror Demister Pads - Specifications and Prices Model Volts Watts Dimensions (mm) List Price MD x MD x MD x MD x web sales@bnthermic.co.uk tel fax

14 CONTROLS for Underfloor Heating Thermostats UNDERFLOOR HEATING T16CW Touch screen programmable white A16C Manual T16CS Touch screen programmable silver U16C Basic programmable T16CB Touch screen programmable black Floor probe and conduit supplied as standard 'Air and floor or floor only control Smart Thermostats Control heating using ios (8.0 or later) and Android (4.0 or later) devices T16R Optional air sensor for T16C Floor probe and conduit provided with every BN Thermic thermostat S16CW Smart Thermostat - with white, or brushed chrome surround S16CB Smart Thermostat - with black, or black with chrome surround Thermostats Model Load Description Details List Price T16CW 16A Programmable Touch Screen (White) Page T16CS 16A Programmable Touch Screen (Silver) Page T16CB 16A Programmable Touch Screen (Black) Page T16R Optional IP65 remote sensor for T16C thermostats Page S16CW 16A Smart Thermostat white or brushed chrome (installer selects) Page S16CB 16A Smart Thermostat black or black with chrome (installer selects) Page U16C 15A Programmable Thermostat Page A16C 15A Manual Thermostat Page web sales@bnthermic.co.uk tel fax

15 Contactors For use when the installed load exceeds the switching capacity of the thermostat Contactors Model Amperage Max kw (230V 1ph) Details List Price CON Page CON Page CON Page ENCL-D Enclosure for CON-32 and CON-50 Page Wireless Control Our wireless thermostat can provide simple, easy to install control in a single room and is especially convenient when one thermostat is required to control more than one heating mat. It can also control larger loads without requiring a noisy contactor. For multi-room installations, the introduction of a central programmer allows all the rooms in a house to be controlled from a single point. CON-32 Contactor Relay Box Usually mounted at skirting level Switching capacity 16A Supplied with floor probe Suitable for any room Programmable Thermostat Can be paired with up to four relay boxes UNDERFLOOR HEATING Optional Central control Touch Screen device Can be paired with up to 24 thermostats Wireless Control Prices WSB-1 Relay Box Model Description Details List Price WSB-1 Wireless Relay Box 16A Page WST-1 Wireless Thermostat (for use with WSB-1 relay box) Page WSP-1 Wireless Central Programmer Page WSP-1 Central Programmer A Typical Wireless Control System WSP-1 Central Programmer WST-1 Wireless Thermostat LARGE ROOM Requiring 2x WSB-1 Relay Boxes WSB-1 Relay Box WSB-1 Relay Box WST-1 Wireless Thermostat WSB-1 Relay Box SMALLER ROOM Requiring 1x WSB-1 Relay Box WST-1 Wireless Thermostat web sales@bnthermic.co.uk tel fax

16 CRJ Self Regulating Heat Cable for Pipes PIPE FREEZE & GUTTER PROTECTION Prevents water from freezing in metal and plastic pipes Maintains temperature in pipes for a wide variety of industrial processes Supplied by the metre order as much or as little as required Typical Applications Stables and Farms Sprinkler systems Wide variety of industrial plants Features Power consumption decreases as pipe temperature increases Can be cut to length on site Full length earth braid and thermoplastic outer jacket All cables require 230V supply Installed onto pipe and under insulation Cables with EX suffix can be used in hazardous areas Zones 1, 2, 21 and 22 (temperature class T6 with 230V supply) or in safe areas CRJ and CRJM Cables Cables and Prices Model W/m List Price/m (under 50m) List Price/m (50m+) CRJM CRJM CRJ CRJ-25EX (ATEX) CRJ-40EX (ATEX) FOR THERMOSTATS See PAGES 74 & 77 Technical Data Cable Max Circuit Length (0 C start up) Breaker (type C) for Max Circuit Length Max Exposure Temperature (Power On) Max Exposure Temperature (Power Off) CRJM m 16A 65 C 85 C CRJM m 16A 65 C 85 C CRJ m 32A 85 C 85 C CRJ-25X 120m 32A 85 C 85 C CRJ-40X 94m 32A 85 C 85 C 16 web sales@bnthermic.co.uk tel fax

17 Accessories Model Description List Price CRJ-T1 THK THKM CRJ-S PF-T Termination Kit (one per circuit) uses shrink on material suitable for CRJ and CRJM but not for use when ATEX approval required. Prepares cable for electrical connection and seals the far end. Termination Kit (one per circuit) uses silicone can be used when ATEX approval required or for general purpose applications (not for use with CRJM). Prepares cable for electrical connection and seals the far end. Termination Kit (one per circuit) uses silicone for use with CRJM. Prepares cable for electrical connection and seals the far end. Splice/T Kit one for every splice or T joint. Not for use when ATEX approval required. Fixing Tape (33mm x 19mm) for fixing cable to pipe max temp 80 C PIPE FREEZE & GUTTER PROTECTION AL-50 Aluminium Tape (45m x 50mm) for wrapping plastic pipes before installing cable or for fixing cable to pipe - max temp 110⁰C (note maximum exposure temp of cable) PF-L Caution Label (10 pack) apply to outside of insulation for safety 6.00 THB Stainless Steel Bracket for THJ junction boxes or THT thermostats c/w stainless steel bands for fixing to pipe for insulation up to 50mm thick and pipes up to 150mm diameter THJ Junction Box IP66 6way terminal block 40A max THJEX ATEX Junction Box with 3 x M20 entries (one plugged) 6 way terminal block 16A max THT Capillary Thermostat 5 to 50 C IP66 (16A). See page THTEX ATEX Capillary Thermostat 0 to 40 C IP66 (16A). See page FST2-IN Frost Thermostat Indoor Use (20A) see page FST2-EX Frost Thermostat Outdoor Use (20A) see page web sales@bnthermic.co.uk tel fax

18 CRJ Self Regulating Heat Cable for Pipes - Continued PIPE FREEZE & GUTTER PROTECTION Selection Table Pipe Freeze Protection (based on a minimum ambient temperature of -20 C and mineral wool insulation). Cable installed in a straight line. Outside Pipe Diameter Insulation Thickness (mm) mm ( ½ Pipe) CRJM-11 CRJM-11 CRJM-11 25mm ( 1 Pipe) CRJM-11 CRJM-11 CRJM-11 50mm (2 Pipe) CRJM-17 CRJM-11 CRJM-11 75mm (3 Pipe) CRJ-25 CRJM-17 CRJM mm (4 Pipe) CRJ-40 CRJM-17 CRJM mm (6 Pipe) CRJ-25 CRJM mm (8 Pipe) CRJ-40 CRJM-17 Trace heated pipe ready for insulation to be installed CRJ-40X maintaining pipe temperature in an industrial plant 18 web sales@bnthermic.co.uk tel fax

19 Selection Table - Temperature Maintenance (based on a minimum ambient temperature of -15 C, carbon steel pipe and mineral wool insulation). Cable installed in a straight line. Outside Pipe Diameter Pipe Temperature 25mm Thick Insulation 50mm Thick Insulation 25mm (1 Pipe) 20 C CRJ-25 CRJ C CRJ-25 CRJ C CRJ-40 CRJ C CRJ-40 50mm (2 Pipe) 20 C CRJ-25 CRJ C CRJ-40 CRJ C CRJ C CRJ-40 75mm (3 Pipe) 20 C CRJ-25 CRJ C CRJ-40 CRJ C CRJ mm (4 Pipe) 20 C CRJ-40 CRJ C CRJ C CRJ-40 PIPE FREEZE & GUTTER PROTECTION Important s Changes in selection parameters can affect cable selection. Please call BN Thermic to discuss cable selection for your project. Additional pipe temperature control is always recommended This selection table is designed to cover the more commonly encountered applications. If your requirements fall outside the limit of this table, please call BN Thermic. Buswires. Inherently temperature-safe self-regulating matrix. Thermoplastic electrical insulation CRJ-40 Nominal output for cable installed on an insulated carbon steel pipe Continuous conductive covering of metal braid W/m 20 CRJ-25 Thermoplastic outer jacket CRJ Self Regulating Cable - Dispensed by the metre Pipe Temperature (⁰C) web sales@bnthermic.co.uk tel fax

20 PW Pipe Freeze Protection Kits MIRROR DEMISTERS Prevents water from freezing in metal and plastic pipes Avoids the cost and inconvenience of burst water pipes Quick and simple to install Applications Domestic properties Commercial premises Mobile homes Features 1.5m power lead and 3-pin plug Built-in thermostat (pre-set at 3 C) Fully moisture proof All cables require 230V supply Installed onto pipe and under insulation (20mm max) Straight run of cable protects pipes up to 50mm dia. Can be wound in an evenly spaced helix (always use the shortest suitable cable) PW Water Pipe Freeze Protection Cable a low price for peace of mind Cables and Prices Model Watts Heated Length List Price (m) PW PW PW PW PW PW PW PW PW PW PW-06 with built-in thermostat and UK plug Accessories Model Description List Price PF-L Caution label (10 pack) apply to outside of insulation 6.00 PF-T Fixing Tape (33m x 19mm) 2.10 AL-50 Aluminium Tape (45m x 50mm) for wrapping plastic pipes before installing cable PF-T Fixing Tape AL-50 Aluminium Tape PF-L Caution Labels 20 web sales@bnthermic.co.uk tel fax

21 WM Self Regulating Hot Water Maintenance Cable Maintains hot water in pipes at desired temperature Ensures hot water is instantly available Eliminates need for return pipework and re-circulating pumps Typical Applications Hot water pipes in both domestic and commercial buildings. Features Maintains water temperature at approximately 50 C to 60 C Output reduces automatically as water temperature rises Can be cut to length on site Full length earth braid Requires 230V supply and must be installed under insulation WM heating cable maintaining hot water temperature in a school before insulation added PIPE FREEZE & GUTTER PROTECTION Insulation Thickness (mm) Cable should be installed in a straight line under installation Maintain Temperature 15mm Pipe 22mm Pipe 28mm Pipe 35mm Pipe 42mm Pipe 54mm Pipe 60 C C C Maximum Circuit Length and Breaker Size Max. Circuit (m) Breaker (A) Accessories Model Description List Price CRJ-T1 Termination Kit (one per circuit) uses shrink on material THK Termination Kit (one per circuit) uses silicone CRJ-S Splice/T Kit (one for every splice or T joint) PF-L Caution label (10 pack) apply to 6.00 outside of insulation PF-T Fixing Tape (33m x 19mm) 2.10 AL-50 Aluminium Tape (45m x 50mm) for wrapping plastic pipes before installing cable THJ Junction Box IP66 6 way terminal block 40A PF-T Fixing Tape Cable and Price Model W/m List Price/m WM AL-50 Aluminium Tape PF-L Caution Labels web sales@bnthermic.co.uk tel fax

22 S Series Snow and Ice Melting Heating Mats PIPE FREEZE & GUTTER PROTECTION Prevents accumulation of snow and ice Ensures year-round access to domestic and commercial buildings Ensures safety in icy conditions Typical Applications Driveways Ramps Disabled access Patios Parking areas Pavements Features Two-core cable assembled onto a web 5m cold lead Continuous earth braid 400W/m² power density Selection and Installation Simply select the mat or combination of mats that cover the area that requires protection. S Series mats can be installed in concrete or in fine washed sand below paving slabs. Basic control can be achieved using a simple frost thermostat. However, for larger installations, we recommend a thermostat that monitors both temperature and moisture. S Series Snow and Ice Melting Mat. An economic means of preventing the accumulation of snow and ice. 10 S Series - Snow and Ice Melting Mats Model Heated Area (m²) Mat Size (m) kw List Price S x S x S x S x S x S x S x S x S x S x S x ERC Snow and Ice Melting Mat providing safe access to an office building Thermostat Description Model Details List Price Weatherproof frost thermostat FST2-EX Page FST2-EX Low cost control for smaller installations 22 web sales@bnthermic.co.uk tel fax

23 GP Self-regulating cable for Gutters and Downpipes Stops accumulation of snow and ice Prevents damage to gutters and properties Reduces danger from collapsing gutters and falling icicles Applications Domestic properties Commercial Premises Features Power consumption decreases as ambient temperature increases No chance of hot spots from cables crossing or touching Can be cut to length on site UV resistant Full length earth braid Use a single run for gutters up to 120mm wide and an additional run for every extra 120mm Cables require 230V supply Connection to power lead via THJ junction box Tin coated copper bus wires Self limiting polymer with bonded jacket Thermoplastic insulation Keep gutters and downpipes ice-free FST2-EX IP65 Frost Thermostat PIPE FREEZE & GUTTER PROTECTION Metal braid Cable Price Model W/m List Price/m GP Thermoplastic over jacket Structure of GP-18 heating cable THK Termination Kit THJ IP66 Junction Box Accessories Model Description List Price THK Termination kit (one per cricuit) uses silicone THJ Junction box IP66 6-way terminal block 40A max GP-S Spacer Kit (also protects against sharp edges) Optional Control GP-S spacer kit Type Description Model Details List Price Thermostat IP65 Frost thermostat FST2-EX Page Cable length against breaker size (assuming 00C start up) Breaker (A) Max Cable length (m) GP-S spacer protecting GP-18 cable from a sharp edge web sales@bnthermic.co.uk tel fax

24 Don't forget... provides FREE OF CHARGE heating designs 24 web tel fax

25 Commercial and Industrial Heaters and Controls Commercial and Industrial Heaters and Controls web tel fax

26 SystemX The Flexible Fan Heating System FAN ASSISTED HEATERS Mix and match fan heaters and air curtains in a control daisy chain Control any combination of heaters and air curtains in any combination and any sequence All control connections by Cat5 cable for super quick and error free installation Controllers do not require their own 230V supply Ceiling Grid Heaters (600 x 600 grid) Model kw Tech Data List Price XC See SCHG-30 (page 28) XC See SCHG-45 (page 28) XC See SCHG-60 (page 28) Wall Mounted Fan Heater/Overdoor Heater Model kw Length (mm) Tech Data List Price XD See 830 (page 32) XD See 860 (page 32) XD-90* See 890 (page 32) *XD-90 suitable for overdoor duty only. Surface Mount Ceiling Heaters (can be suspended) Model kw Tech Data List Price XS See SMH-30 (page 30) XS See SMH-45 (page 30) XS See SMH-60 (page 30) Recessed Heaters Model kw Length (mm) Tech Data List Price XR See RH-20 (page 34) XR See RH-30 (page 34) XR See RH-60 (page 34) Commercial Air Curtains Model kw Length (mm) Tech Data List Price XAS See CAS-30 (page 36) XAS See CAS-45 (page 36) XAD See CAD-60 (page 36) XAD See CAD-90 (page 36) XAT See CAT-90 (page 36) XAT See CAT-135 (page 36) web sales@bnthermic.co.uk tel fax

27 Industrial Fan Heaters Model kw Tech Data* List Price CX1 with thermostat CX2 with tamper resistant thermostat CX3 without thermostat CX6 digital controller CXS optional remote sensor for CX1, CX2 or CX6 XH See OUH2-03 (page 40) XH See OUH2-05 (page 40) XH See OUH2-07 (page 40) XH See OUH2-10 (page 40) XH See OUH2-15 (page 40) XH See OUH2-20 (page 40) XH See OUH2-25 (page 40) *XH models do not have a built-in thermostat System X control components All System X controllers provide high heat/low heat/fan only (summer use) settings and do not require their own 230V supply Type Description Model Details List Price Controller Controller Controller Controller Sensor Cable Cable Cable Joiner With thermostat With tamper resistant thermostat Without thermostat With digital programmable thermostat Optional remote sensor for use with CX1, CX2 or CX6 Cat5 terminated 5m Cat5 terminated 10m Cat5 terminated 20m Cat5 Cable Joiner CX1 Page CX2 Page CX3 Page CX6 Page CXS Page DX DX DX JX FAN ASSISTED HEATERS Daisy chain can consist of up to 12 identical heaters OR Different heaters in any combination or sequence web sales@bnthermic.co.uk tel fax

28 SCHG Fan Assisted Heaters for 600 x 600 Ceiling Grid FAN ASSISTED HEATERS High quality commercial fan heaters manufactured in the UK Ceiling mounting allows free use of floor and wall space Suitable for a wide range of commercial premises Applications Shops Cafes Changing rooms Entrance Areas Features Designed to rest in the T bar of a 600 x 600 suspended ceiling grid Air inlet and outlet through the front panel no requirement for air supply from the ceiling void White aluminium egg-crate grille supplied with every heater Pre-wired to convenient rear-mounted terminal enclosures Output can be reduced from high to low by removing link in terminal enclosure Built-in electronic thermostat ('T' suffix only) All models can be switched directly by the CS-7 switch and/or RST2-IN or RST-TP thermostat CS-7 switch for high/low/fan only settings Heater range and pricing Model kw Built-in Thermostat List Price SCHG No SCHG-30T 3.0 Yes SCHG No SCHG-45T 4.5 Yes SCHG No SCHG-60T 6.0 Yes kW and 4.5kW heaters and grille Physical Data kw Dimension (mm) Required clearance Weight W D H above grid (mm) (kg) kW heater and grille 28 web sales@bnthermic.co.uk tel fax

29 Performance Data kw Volts Airflow (m³/h) Recommended Mounting Height (m) High Low Min Max *Noise levels are factory tested not laboratory tested Control Options and Prices Type Description Model Details List Price Switch On/off/high heat/low heat/fan only CS-7 Page Thermostat Adjustable thermostat (not for use with 'T' suffix models) RST2-IN Page Thermostat Tamperproof thermostat (not for use with 'T' suffix models) RST-TP Page FAN ASSISTED HEATERS 3kW providing comfort heat for customer at an industrial trade counter An SCHG fan heater provides simple and reliable heating in a car service reception area Heater specifically designed for integration into a suspended ceiling grid FOR MULTI-HEATER SYSTEMS WE RECOMMEND OUR SYSTEM X - See PAGE 26 web sales@bnthermic.co.uk tel fax

30 SMH Surface Mount Ceiling Heaters FAN ASSISTED HEATERS High quality commercial fan heaters manufactured in the UK Ceiling mounting allows free use of floor and wall space Ideal for premises that do not have suspended ceilings Applications Shops Cafes Changing rooms Entrance Areas Features Compact smart design with white paint finish Simple keyhole screw fixing to a conventional ceiling M6 threaded holes for suspension by drop rods Output can be reduced from high to low by removing link in terminal enclosure Built-in electronic thermostat ('T' suffix only) All models can be switched by the CS-7 controller Models without built-in thermostat can be controlled by the CS-7 controller and/or RST2-IN or RST-TP thermostat 3kW and 4.5kW versions Heater Range and Prices Model kw Built-in Thermostat List Price SMH No SMH-30T 3.0 Yes SMH No SMH-45T 4.5 Yes SMH No SMH-60T 6.0 Yes Physical Data kw Dimension (mm) Weight (kg) 6kW Model W D H SMH heater suspended from drop rods Performance Data kw Volts Airflow (m³/h) db*@2m Recommended Mounting Height (m) High Low Min Max / / / CS-7 switch for high/low/fan only settings *Noise levels are factory tested not laboratory tested 30 web sales@bnthermic.co.uk tel fax

31 Control Options and Prices Type Description Model Details List Price Switch On/off/high heat/low heat/fan only CS-7 Page Thermostat Adjustable thermostat (not for use with 'T' suffix models) RST2-IN Page Thermostat Tamperproof thermostat (not for use with 'T' suffix models) RST-TP Page FAN ASSISTED HEATERS The rugged SMH is well suited to industrial applications SMH heaters installed in an auction house Warming customers in a factory outlet FOR MULTI-HEATER SYSTEMS WE RECOMMEND OUR SYSTEM X - See PAGE 26 web sales@bnthermic.co.uk tel fax

32 800 Series High Level Wall or Overdoor Fan Assisted Heaters High quality commercial fan heaters manufactured in the UK Smart modern appearance Can be used as a general purpose commercial space heater or as an overdoor heater FAN ASSISTED HEATERS Typical Applications Space heating or overdoor heating in the following premises Shops Entrance Areas Cafes Community halls Changing rooms Workshops Features Smart design with attractive white paint finish Dual function bracket: vertical discharge (overdoor) or angled discharge (general space heating) - overdoor only for 9kW models M8 threaded hole for drop rod suspension Panel front on/off switch Pre-wired to rear-mounted terminal enclosures Output can be reduced from high to low by removing link in terminal enclosure Built-in electronic thermostat ('T' suffix only) All models can be switched by the CS-7 controller Models without built-in thermostat can be controlled by the CS-7 controller and/or RST2-IN or RST-TP thermostat 830T with wall bracket fitted 860T with wall bracket fitted 890T Model with built in thermostat Heater Range and Prices Model kw Built-in Thermostat List Price No T 3.0 Yes No T 6.0 Yes No T 9.0 Yes Physical Data kw Dimension (mm) Weight (kg) W D H CS-7 switch for high/low/fan only settings Overdoor heater providing a warm welcome for customers 32 web sales@bnthermic.co.uk tel fax

33 Performance Data kw Volts Airflow (m³/h) Recommended Mounting Height (m) High Low Min Max V or 400/3N *Noise levels are factory tested not laboratory tested Control Options and Prices Type Description Model Details List Price Switch On/off/high heat/low heat/fan only CS-7 Page Thermostat Adjustable thermostat (not for use with 'T' suffix models) RST2-IN Page Thermostat Tamperproof thermostat (not for use with 'T' suffix models) RST-TP Page Overdoor heater installed to provide a 450 warm air stream FAN ASSISTED HEATERS 6kW heater combatting draughts in a Hampshire church 6kW heater installed in a trendy juice bar FOR MULTI-HEATER SYSTEMS WE RECOMMEND OUR SYSTEM X - See PAGE 26 web sales@bnthermic.co.uk tel fax

34 RH Recessed Fan Assisted Heaters High quality commercial fan heaters manufactured in the UK Recessed installation reduces visual impact Suitable for ceiling or wall mounting FAN ASSISTED HEATERS RH-30 3kW recessed heater commonly installed above a door RH-20 Extremely compact 2kW recessed heater RH-60 6kW recessed heater with integral relay Typical Applications Space heating or overdoor heating in the following premises Shops Cafes Changing rooms Entrance Areas Community halls Workshops Features Air inlet and output through front panel no requirement for air supply to the rear of the heater White aluminium grille is the only visible part of heater Suitable for horizontal or vertical discharge Simple fixing through the face of the heater Pre-wired to rear-mounted terminal enclosures Output can be reduced from high to low by removing link in terminal enclosure Can be switched directly by the CS-7 switch and/or RST2-IN or RST-TP thermostat Heater Range and Prices Model kw List Price RH RH RH RH-30 providing comfort heat in a charity shop 34 web sales@bnthermic.co.uk tel fax

35 FAN ASSISTED HEATERS A pair of 3kW heaters welcoming customers in a shopping mall Recessed heater installed above a doorway to combat draughts Physical Data kw Dimension (mm) Aperture A B Size (mm) Insert Clearance (mm) Weight (kg) x x x Performance Data kw Volts Airflow db*@2m Recommended Mounting Height (m) High Low (m³/h) Min Max *Noise levels are factory tested not laboratory tested Control Options and Prices Type Description Model Details List Price Switch On/off/high heat/low heat/fan only CS-7 Page Thermostat Adjustable thermostat RST2-IN Page Thermostat Tamperproof RST-TP Page CS-7 switch for high/low/ fan only settings FOR MULTI-HEATER SYSTEMS WE RECOMMEND OUR SYSTEM X - See PAGE 26 web sales@bnthermic.co.uk tel fax

36 CA Commercial Air Curtains new Produces a higher air velocity than an overdoor heater for a more effective air screen Helps to reduce heating costs by inhibiting heat losses Electric heating elements offset chill factor associated with fast air movement and contribute to indoor air temperature FAN ASSISTED HEATERS CAS CAD Typical Applications Convenience stores Hotel lobbies Features Smart design with attractive white paint finish Bracket for wall or ceiling mounting M8 threaded holes for drop rod suspension Built-in electronic thermostat ( T suffix only) All models can be switched by CS-7 controller All models without built-in thermostat can be switched by CS-7 controller and/or an RST-IN or RST-TP thermostat CAT Important Note CA commercial air curtains produce higher decibels than the equivalent overdoor heaters. Please ensure that noise levels are acceptable before installing. Air Curtain Range and Prices Model kw Built-in Thermostat Length (mm) List Price CAS No CAS-30T 3.0 Yes CAS No CAS-45T 4.5 Yes CAD No CAD-60T 6.0 Yes CAD No CAD-90T 9.0 Yes CAT No CAT-90T 9.0 Yes CAT No CAT-135T 13.5 Yes Physical Data Models Dimensions (mm) Weight (kg) L D H CAS CAD CAT web sales@bnthermic.co.uk tel fax

37 Performance Data Model kw Volts Airflow (m³/h) Recommended Mounting Height (m) High Low Min Max CAS-30(T) CAS-45(T) CAD-60(T) CAD-90(T) CAT-90(T) or 400/3N CAT-135(T) or 400/3N *Noise levels are factory tested not laboratory tested Insects Air intake Warm air in Winter Typical air flow from a CA air curtain FAN ASSISTED HEATERS Pollution Cool air in Summer Control Options and Prices Type Description Model Details List Price Switch On/off/high heat/low heat/fan only CS-7 Page Thermostat Adjustable thermostat (not for use with T suffix models) RST2-IN Page Thermostat Tamperproof thermostat (not for use with T suffix models) RST-TP Page FOR MULTI-HEATER SYSTEMS WE RECOMMEND OUR SYSTEM X - See PAGE 26 web sales@bnthermic.co.uk tel fax

38 HCA High Capacity Air Curtain Provides an invisible barrier across entrances to commercial premises Reduces heating and air conditioning costs Minimises ingress of pollutants FAN ASSISTED HEATERS Typical Applications Large shops Offices Hospitals Hotels Features Attractive, sturdy design Wall mounting plate supplied as standard HCA air curtains reduce heating costs Four M6 threaded holes for drop rod suspension Control box provided with every air curtain offering high and low settings for airflow and heat Air Curtain Range and Prices Model kw (high setting) Length (mm) List Price HCA HCA HCA Physical Data Model Dimensions (mm) Weight (kg) L D H HCA HCA HCA Performance Data Model Volts kw Airflow (m³/h) 3m Recommended Mounting Height (m) High Low High Low Min Max HCA /3N HCA /3N HCA /3N *Noise levels are factory tested not laboratory tested Optional Thermostats and Prices Description Model Details List Price Standard room thermostat RST2-IN Page Tamperproof thermostat RST-TP Page Thermostats are connected to the control box and will control heat output while the fan operates continuously. Control box supplied as standard Important Note. For an HCA air curtain to provide an effective air barrier, a high air velocity is required. The resulting noise output must be considered. For this reason, we do not recommend HCA air curtains for smaller shops or where people are working in close proximity to the entrance. 38 web sales@bnthermic.co.uk tel fax

39 Pair of 18kW air curtains mounted above automatic sliding doors in a supermarket FAN ASSISTED HEATERS An air curtain looking the part in a prestige London office building HCA air curtains reducing heating costs in a DIY store HCA air curtain suspended from drop rods web sales@bnthermic.co.uk tel fax

40 OUH2 Industrial Fan Heaters FAN ASSISTED HEATERS An effective means of heating industrial premises Extremely robust UK manufactured heaters Exceptional reliability backed by a 5 year warranty Typical applications Warehouses Workshops Factories Features FIVE YEAR WARRNTY Heavy gauge steel construction Bracket provided with every heater for wall or ceiling mounting Suitable for vertical suspension hooks provided as standard Built-in temperature control thermostat Optional control switch providing on/off/fan only settings A number of heaters can be controlled from a single point Auto-reset over-temperature protection and heat purge device to clear residual heat 5 OUH2 Unit Heater Robust, Rugged, Reliable Heater Range and Prices Model kw List Price OUH OUH OUH OUH OUH OUH OUH Physical Data kw Dimensions (mm) Weight W D H (kg) 3 to to Built to last an OUH industrial fan heater is covered by a 5-year warranty 40 web sales@bnthermic.co.uk tel fax

41 Not sure whether that s the Batmobile but it s definitely kept warm by a BN Thermic heater Performance Data Model kw Volts Airflow db*@ 2m (m³/h) OUH V or 400/3N OUH V or 400/3N OUH V or 400/3N OUH V/3N OUH V/3N OUH V/3N OUH V/3N *Noise levels are factory tested not laboratory tested FAN ASSISTED HEATERS OUH2 Unit Heater suspended using hooks provided Where roof height exceeds 4m we recommend using our DSU Destratification units see page 43 25kW industrial fan heater installed in an automotive parts store Control Options and Prices Type Description Model Details List Price Switch On/off/fan only settings OUH2-S Page Timer Programmable PROTIM-7 Page Thermostat Frost protection (overrides heater s built-in thermostat) FST2-IN Page No neutral, 440V and 480V versions available - contact BN Thermic Continued... web sales@bnthermic.co.uk tel fax

42 OUH2 Industrial Fan Heaters Continued Mounting Options FAN ASSISTED HEATERS OUH2-S control switch fitted to a heater. Can be wall mounted if preferred A Typical Control Group The group can be a combination of any models from the OUH2 range FOR MULTI-HEATER SYSTEMS WE RECOMMEND OUR SYSTEM X - See PAGE web sales@bnthermic.co.uk tel fax

43 DSU Destratification Units Reducing heating bills by up to 30% by recycling warm air that has collected at high level. Recommended for industrial premises where roof height exceeds 4m Typical Applications Warehouses Exhibition Halls Ideally suited for use in conjunction with BN Thermic s OUH2 industrial fan heaters Features Reduces energy costs when roof Reduces heating costs by up to 30% height exceeds 4m Heavy duty steel construction Built-in thermostat automatically energises fan 4-way adjustable louvers Suspension kit supplied as standard (4 x 500mm chains and associated hooks) FAN ASSISTED HEATERS Specification and Prices Model Volts Airflow (m³/h) Fan Motor (W) Dimensions (mm) Roof height (m) Area Covered (m) db* at 5m Weight (kg) List Price H W D DSU to 7 20 x DSU to x *Noise levels are factory tested not laboratory tested. Warehouse Example Without DSU Warm air accumulates at high level Destratification unit reducing heating bills in a Cumbrian auction house With DSU Warm air is recycled reducing heating costs by up to 30% Top view of DSU-8 showing powerful fan web sales@bnthermic.co.uk tel fax

44 PH Pew Heaters new PH65 CONVECTION HEATERS PH45 PH30 PH Series - ideal for unobtrusive installation under a church pew An economic means of heating a church congregation Minimal pre-heating required ensuring low running costs Visually unobtrusive Features Robust all-steel construction Dark brown paint finish Fixed directly to a pew s backboard or mounted on floor or suspension brackets 20mm cable knockouts at both ends for electrical connection External guard not required Heater Range and Prices Model Length (mm) kw List Price PH PH PH PH Pew heater installed under a church pew PHF optional floor brackets Heater Technical Data Model kw Volts Dimensions (mm) Weight (kg) L D H PH PH PH PHB optional suspension brackets 44 web sales@bnthermic.co.uk tel fax

45 Optional Brackets (for pews without backboards) Type Description Model List Price Bracket Floor (pair) assembled height 204mm PHF Bracket Suspension (pair) assembled height 325mm PHB Pew Heater Section Table Space Between Seat Supports (mm) Minimum Maximum Recommended Heater PH PH PH Multiple Heaters Spaces between seat supports CONVECTION HEATERS Pew heaters fitted directly to pew backboards Pew heater installed using floor brackets suspension brackets are also available web tel fax

46 SWD Industrial Finned Tubular Heaters CONVECTION HEATERS Ideal for damp and corrosive environments Suitable for hose-down washing Designed for long life in the most demanding conditions Features Welded stainless steel construction Built-in adjustable thermostat (SWD-A models only) Brackets for wall or floor mounting supplied as standard Waterproof glass fibre terminal box IP66 rated M20 cable gland supplied as standard Optional zinc plated wire guards available (recommended when personnel have access to the heater) SWD Industrial Finned Tubular Heater ideal for damp and corrosive environments Heater Range and Prices Model kw Volts Built-in Thermostat List Price SWD-A V Yes SWD-A V Yes SWD-A V Yes SWD-A V Yes SWD-A V Yes SWD-U V No SWD-U V or 400V/3 No SWD-U V or 400V/3 No SWD-U V or 400V/3 No SWD-U V or 400V/3 No SWD-U V or 400V/3 No SWD-U V No SWD-U V No SWD-U V No SWD-A with externally adjustable thermostat Heater Technical Data kw Dimensions (mm) Weight (kg) Optional L W H Guard SWG SWG SWG SWG SWG SWG-5 SWD-U standard format 46 web sales@bnthermic.co.uk tel fax

47 Optional Guard Range and Prices Model List Price SWG SWG SWG SWG SWG Optional Guard Technical Data Model Dimensions (mm) Weight L W H (kg) SWG SWG SWG SWG SWG SWD mounted under SWG Guard An SWD guard is recommended when personnel have access to the heaters CONVECTION HEATERS SWD heaters can be floor mounted or wall mounted using the brackets provided A wall-mounted heater installed under a robust wire guard web sales@bnthermic.co.uk tel fax

48 TX Explosion-Proof Tubular Heaters CONVECTION HEATERS ATEX Certified for use in Hazardous Areas Suitable for Zone 1 and Zone 2 areas (gas) and Zone 21 and Zone 22 areas (dusts) Typical applications Spray shops Petrochemical installations Storage areas where hazardous gases or dusts may be present Features ATEX Certified Equipment protection level Gb (gas) and Db (dust) Certified for Zones 1, 2, 21 and 22 Groups IIC (gas) and IIIC (dust) Temperature Class T3 (maximum ambient 40 C) IP66 rating Steel construction with grey epoxy finish Sturdy mounting feet for wall or floor mounting Optional galvanised steel mesh safety guard Also available (consult BN Thermic) T4 models Alternative outputs up to 2.4kW Alternative voltages including 3 phase Low and high ambient temperature models Stainless steel construction Heater Range and Prices Model kw List Price TXT TXT3-05* TXT3-10* TXT3-15* TXT TXST-01 ATEX approved thermostat for use with hazardous gases *Generally available from stock 48 web sales@bnthermic.co.uk tel fax

49 Heater Specifications Model kw Dimensions (mm) Weight Optional Guard L H W (kg) TXT TXG-01 TXT3-05* TXG-01 TXT3-10* TXG-02 TXT3-15* TXG-01 + TXG-02 TXT x TXG-02 Guards TXG guards are recommended for installations where personnel have access to heaters. The guards are open ended allowing more than one guard to be used to protect a single heater. Guards Model Length List Price TXG mm TXG mm Thermostat Options and Prices CONVECTION HEATERS Description Model Details List Price ATEX thermostat (hazardous gas only) ATEX thermostat (hazardous dust and gas) TXST-01 Page TXST-02 Page TXST-02 ATEX approved thermostat for use with hazardous gases and dusts TX ATEX approved heaters installed in a hazardous area web sales@bnthermic.co.uk tel fax

50 BLS 110V Low Level Convector Heaters CONVECTION HEATERS For use where only 110V supply is available Provides comfort or background heat Low running costs Typical Applications Site huts Space heating in a wide variety of commercial and industrial premises Features Robust steel construction with central baffle plate to promote convection currents Long life metal sheathed finned heating element Auto-reset over-temperature protection Built-in thermostat with external knob allowing easy adjustment of temperature set-point BLS T 110V robust convector heater ideal for site huts Price Model List Price BLS T Heater Technical Data kw Volts Dimensions (mm) Weight (kg) L D H We have a heater for almost every heating application Please call our technical sales team for help with heater selection 50 web sales@bnthermic.co.uk tel fax

51 Magic Lamp Introducing the REVOLUTIONARY... BN Thermic halogen heaters and patio heaters are now available with the brand-new Magic Lamp. These heaters are true shortwave halogen heaters, and will perform as such, but produce a barely perceptible pink glow. RADIANT HEATERS Magic Lamp heaters are perfect for any installation which requires instant, direct heat but where significant light output cannot be tolerated. Typical applications: Churches Dining areas Sports facilities Show rooms Studios Animal enclosures Magic Lamp Patio Heaters can be seen on page 54 Gentle pink glow from a Magic Lamp Magic Lamp Halogen Heaters can be seen on page 58 Heaters using the Magic Lamp should not be confused with medium-wave low glow heaters. Magic lamp heaters emit shortwave energy which can travel several metres without losing intensity or being affected by draughts and breezes. web sales@bnthermic.co.uk tel fax

52 ETH 'All Black' Radiant Heater RADIANT HEATERS Provides direct comfort heat without light output Ideally suited to dining areas Typical Applications Commercial and domestic installations Dining areas Lunch counters Bars Conservatories Orangeries 'All Black' Radiant Heater smart modern design Features Sophisticated all black design IP44 rated Radiant heat with no light output Wall mounting bracket with up and down angle adjustment supplied as standard Suitable for suspension (multi-heater brackets available) Pre-wired 2m high temperature cable Heater Range and Prices Model kw List Price ETH ETH 'All Black' heaters are ideal for suspension above dining areas Technical Specification Model kw Volts Dimensions(mm) Weight (kg) H W D ETH kw ETH kW Control Options and Prices Description Model Details List Price Push Button Timer (3kW max) TS-6 Page Push Button Timer (6kW max) TS-5 Page ETH heaters installed indoors in a Norfolk sports club 52 web sales@bnthermic.co.uk tel fax

53 Optional Multi-Heater Brackets Description Model List Price Brackets for 2 heaters (suspend or wall-mount) ETH-B Brackets for 3 heaters (suspend or wall mount) ETH-B Brackets for suspending or wall-mounting 2 and 3 heaters RADIANT HEATERS Two heaters suspended using a ETH-B2 bracket in a sheltered dining area 'All Black' heaters mounted above a bar in London's Waterloo Station web sales@bnthermic.co.uk tel fax

54 HWP2 Patio Heater RADIANT HEATERS Safe, instant outdoor heating Equally suitable for commercial or domestic installations Can be installed outdoors and left outdoors all year round Typical Applications Patios both commercial and domestic Pub gardens Pavement cafes Golf driving ranges Nightclub queuing areas Smoking areas Features IP55 rated for outdoor use equally suited to indoor applications Aluminium construction with stainless steel safety grille Stylish design with choice of black, white or silver paint finish High quality replaceable halogen lamp with an average 7000 hours operating life Wall mounting bracket with up and down angle adjustment supplied as standard Parasol clamp supplied as standard with single lamp heaters Suitable for suspension Pre-wired 3m high temperature cable HWP2-B HWP2-S HWP2-W HWP2-2B HWP2-2W HWP2-3B HWP2-3W HWP2-45B Instant comfort heat in a gazebo 2kW patio heaters keeping golfers warm at a driving range 54 web sales@bnthermic.co.uk tel fax

55 Optional Accessories and Prices Description Model Details List Price Dimmer (3kW max) VR-2 Page Push Button Timer TS-6 Page (3kW max) Push Button Timer TS-5 Page (6kW max) Movement Sensor WH-402 Page A 3kW heater suspended A Battersea bistro providing a warm outdoor dining area RADIANT HEATERS Heater Range and Prices Model kw Finish Lamp Glow List Price HWP2-B 1.5 Black Gold HWP2-BM 1.5 Black Magic Lamp (See page 51) HWP2-W 1.5 White Gold HWP2-WM 1.5 White Magic Lamp (See page 51) HWP2-S 1.5 Silver Gold HWP2-SM 1.5 Silver Magic Lamp (See page 51) HWP2-2B 2.0 Black Red HWP2-2BM 2.0 Black Magic Lamp (See page 51) HWP2-2W 2.0 White Red HWP2-2WM 2.0 White Magic Lamp (See page 51) HWP2-3B 3.0 Black Red HWP2-3W 3.0 White Red HWP2-45B 4.5 Black Red HWP2 Heaters now available in FORMAT All the performance of a true halogen heater but with the gentlest pink glow. See page 51 for full details. Continued... web sales@bnthermic.co.uk tel fax

56 HWP2 Patio Heaters Continued Area Coverage Wall mounted Wall Mounted kw H (m) X (m) Y (m) Z (m) Area (m²) 1.5 or 2kW or 2kW H Y X Z RADIANT HEATERS Area Coverage Overhead Mounted kw H (m) X (m) Y (m) Area (m²) 1.5 or 2kW or 2kW HWP2-S heaters providing instant heat in the smartest-looking smoking area we have ever seen! H Overhead mounted Technical Specification kw Volts Lamp Type Glow Dimensions(mm) Weight (kg) H W D 1.5kw 230 Frosted* Gold* kW 230 Gold Red kW 230 Gold Red kW 230/400 Gold Red * available in 'Magic Lamp' format (see page 55). Y X Lovely warm pub garden makes you want to stay for just one more! Instant heat all year round for East London hipsters! 56 web sales@bnthermic.co.uk tel fax

57 new CM Heated Chandelier Top quality medieval style chandelier providing light and heat Heaters hidden inside chandelier ring for minimal visual impact Magic Lamp technology ensures that light output from the heaters is barely noticeable Typical Applications Churches Wedding Barns Banqueting Halls Features Robust steel construction with black paint finish Halogen heaters providing instant direct heat with barely discernible light output Heaters can be wired for 230V 1ph or 400V 3ph and neutral SES lamp holders (lamps by other maximum load 1kW) Separate circuit for heating and lighting Chains and ceiling rose supplied ceiling suspension chain 5m long CM3 Heated Chandelier - the light output from the three Magic Lamp heaters is barely noticeable RADIANT HEATERS Range and Prices Model Heater Output (kw) List Price CM CM CM CM CM4 Heated Chandelier fitted with four Magic Lamp heaters Selection Guide Heater Size Suggested Mounting Height Heated Area (approx) CM3 4m 5.5m dia CM4 5m 7m dia Technical Specification Model Total Heat Output (kw) No. Heaters No. Lamp Holders Diameter (mm) Height to Terminal Enclosure (mm) Weight (kg) CM CM CM CM web sales@bnthermic.co.uk tel fax

58 HN Series Halogen Heaters Heats people rather than space Ideal for heating specific targets within an otherwise unheated building Instantly effective and therefore ideal for infrequently used buildings RADIANT HEATERS HN2-1500G or HN2-200G Halogen Heater Typical Applications Community halls Churches Workshops Packing areas Squash courts Factories Warehouses HN Heaters now available in FORMAT All the performance of a true halogen heater but with the gentlest pink glow. See page 51 for full details. Features Aluminium construction with safety grille HN2-3000G Halogen Heater High quality replaceable halogen lamp with an average 7000 hours operating life Wall mounting bracket with up and down and side to side' angle adjustment Gold lamp with pink/orange glow Pre-wired 1m high temperature cable (2 core and earth) Lamps on 2 and 3 lamp heaters can be switched individually using remote mounted switch Optional suspension kit available HN2-4500G or HN2-6000G Halogen Heater Rear view of HN2-3000G showing wall bracket and terminal enclosure 58 web sales@bnthermic.co.uk tel fax

59 Heater Range and Prices Model kw List Price HN2-1500G HN2-1500M HN2-2000G HN2-2000M HN2-3000G HN2-3000M HN2-4500G HN2-4500M HN2-6000G HN2-6000M Technical Specification Heaters with a 'G' suffix have gold (red glow) lamps. Heaters with 'M' suffix have Magic Lamps with an almost imperceptible pink glow (see page 51) kw Volts Dimensions(mm) Weight (kg) H W D 1.5kw/2kW kW kW/6kW 230/ kW halogen heater installed in a workshop spot heating is much cheaper than heating the entire building RADIANT HEATERS Each packing station has it s own magic lamp zero glare heater HN Halogen Heater heating a church in Market Harborough Continued... web sales@bnthermic.co.uk tel fax

60 HN Halogen Heaters Continued Wall Mounted H Table 1 - Select appropriate W/m² W/m required X Heavy Work Light Work Spot Heating Y Z Highly Insulated Insulated RADIANT HEATERS Un-Insulated Light Cladding Badly insulated/damp Table 2 - Select heater type and mounting height HN2-1500G or HN2-2000G HN2-3000G HN2-4500G or HN2-6000G Wall Mounted (m) Area Covered Overhead Mounted (m) Area Covered H X Y Z (m²) H X Y (m²) H Y X Overhead Mounted Optional Accessories Description Model Full Details List Price Suspension Kit HSK On/off switch for 1.5kW, 2kW CS-4 Page and 3kW heaters Switch for 3kW heater: CS-2 Page full/½ heat settings Switch for 4.5kW and 6kW CS-3 Page heaters: full/⅔/⅓ heat settings Dimmer (3kW max) VR-2 Page Push Button Timer (3kW max) TS-6 Page Push Button Timer (6kW max) TS-5 Page Movement Sensor (3kW max) WH-402 Page Three phase halogen heaters providing instant heat above industrial sewing machines For multi-heater control see page web sales@bnthermic.co.uk tel fax

61 MC1 Halogen Heater Control Box An MC1 control box provides variable output control for a group of BN Thermic s HN2 halogen heaters from a single point. This approach allows the intensity of heat to be adjusted by means of a simple wall-mounted switch enhancing comfort and improving economy. Each system must incorporate one primary control box and a wall-mounted switch (either CS-2 or CS-3 depending on the heaters being controlled). For larger installations additional secondary control boxes (MC1-S) will be required. Control Box Range and Prices Model Primary/ Secondary Halogen Heaters Controlled Max No. Heaters List Price MC1-P-L2 Primary 2 lamp MC1-S-L2 Secondary 2 lamp MC1-P Primary 3 lamp MC1-S Secondary 3 lamp Switch Range and Prices Model Suitable for Details List Price CS-2 MC1-P-L2 Page CS-3 MC1-P Page RADIANT HEATERS Controlling HN2-3000G (3kW) Heaters each with 2 lamps Each MC1-P-L2 will control up to six heaters. The CS-2 switch allows the heaters lamps to be switched individually meaning that outputs of 1.5kW or 3kW can be selected. CS-2 Wall Mounted Switch MC1-P-L2 MC1-S-L2 Primary Control Box controlling up to six heaters Secondary Control Box each controlling up to six heaters A selection of optional additional control devices WH-402 Movement Sensor CS-5 Push Button (activates rundown timer) CS-6 Master Control Button For larger installations up to eleven secondary control boxes can be connected in a control daisy chain with each controlling up to six additional heaters. FST2-IN Frost Thermostat Continued... web sales@bnthermic.co.uk tel fax

62 MC1 Halogen Heater Control Box Continued Controlling HN2-4500G (4.5kW) Heaters or HN2-6000G (6kW) Heaters each with 3 lamps Each MC1-P will control up to four heaters. The CS-3 switch allows the heaters lamps to be switched individually meaning that outputs of 1/3, 2/3 or full power can be selected. RADIANT HEATERS CS-3 Wall Mounted Switch MC1-P Primary Control Box controlling up to four heaters MC1-S Secondary Control Box each controlling up to four heaters WH-402 Movement Sensor A selection of optional additional control devices CS-5 Push Button (activates rundown timer) CS-6 Master Control Button FST2-IN Frost Thermostat For larger installations up to eleven secondary control boxes can be connected in a control daisy chain with each controlling up to four additional heaters. Two MC-1 control boxes providing variable heat control in a Norfolk church Optional additional control devices and prices Type Description Model Details List Price Thermostat Frost protection overrides switch and other control FST2-IN Page devices Thermostat Prevents heaters being energised above set-point RST2-IN Page (standard model) Thermostat Prevents heaters being energised above set-point RST-TP Page (tamperproof model) Timer Programmable timer PROTIM-7 Page Movement Sensor Prevents unoccupied area from being heated WH-402 Page Push Button Triggers control boxes built-in run down timer (preset CS-5 Page between 5 secs and 18 minutes) Master Control Button Switches the system off overriding everything but frost thermostat CS-6 Page web sales@bnthermic.co.uk tel fax

63 ESP Radiant Cassettes An extremely economic means of heating large commercial spaces Attractive unobtrusive design well suited to modern facilities High mounting positions allows flexible use of floor and wall space Typical Applications Community halls Sports halls Showrooms Food Halls Squash courts Features Radiant heat without light output Robust steel case with white epoxy finish Specially treated aluminium heat emitter Ceiling mounting brackets supplied as standard (these brackets also provide suspension points) Optional angle adjustable wall brackets available The ESP range providing an economic means of heating large areas Radiant cassettes are ideally suited to squash courts Heater Range and Prices Model kw List Price ESP ESP ESP ESP ESP ESP ESP2-B (optional wall bracket - pair) RADIANT HEATERS Radiant Cassettes proving an economic means of heating a community hall Continued... web sales@bnthermic.co.uk tel fax

64 RADIANT HEATERS ESP Radiant Cassettes Continued Energy Saving ESP Radiant Cassettes are our most economic heaters for buildings with high roofs for the following reasons: The gentle radiant effect means that the experienced temperature can be up to 4 C warmer than the actual air temperature. This means that the thermostat can be set up to 4 C lower. The temperature gradient is negligible. Typically air temperature will increase by 0.3 C per metre above floor level. This figure compares to a typical 2.5 C per metre when using fan heaters. Height above floor level Approx Air Temp 6m 18.5 C 5m 18.2 C 4m 17.9 C 3m 17.6 C 2m 17.3 C 1m 17 C Heating a building using ESP Radiant Cassettes Height above floor level Approx Air Temp 6m 32.5 C 5m 30 C 4m 27.5 C 3m 25 C 2m 22.5 C 1m 20 C Heating a large building using fan heaters Energy saving heating in a Brighton theatre BN Thermic radiant cassettes keep customers warm in this Essex taproom 64 web sales@bnthermic.co.uk tel fax

65 ESP2 radiant cassettes are ideal for modern industrial applications such as this glass-printing shop RADIANT HEATERS Technical Specification Model kw Volts Dimensions(mm) Recommended Mounting Height (m) Weight H W D Min Max (kg) ESP ESP ESP ESP ESP / ESP / Control Options and Prices Type Description Model Details List Price Thermostat Hard Case tamperproof HC-T2 Page Thermostat Hard Case tamperproof with temperature set-back HC-ST2 Page Thermostat Tamperproof tool for Hard Case thermostats HC-D Page Timer Programmable PROTIM-7 Page Contactor 32A 3-pole CON-32 Page Contactor 50A 3-pole CON-50 Page Contactor 80A 3-pole CON-80 Page Contactor Enclosure for CON-32 and CON-50 ENCL-D Page web sales@bnthermic.co.uk tel fax

66 RP Radiant Ceiling Panels RADIANT HEATERS A sophisticated means of heating commercial premises Very safe as personnel have no access to heaters High mounting positions allows flexible use of floor and wall space Typical Applications Offices Trade counters Care homes Meeting rooms Features Radiant heat without light output Specifically designed for quick and easy installation into a suspended ceiling grid Fitted with a bracket for easy mounting onto a conventional ceiling Attractive white easy-clean finish Mounting height up to 4m RP-03 provides an almost invisible source of gentle radiant heat Energy Saving RP Ceiling Panels are a more economic means of heating commercial premises than conventional heating systems. The gentle radiant effect means that the experienced temperature can be up to 4 C warmer than the actual air temperature. This means that the thermostat can be set up to 4 C lower. The temperature gradient is negligible. Typically air temperature will increase by 0.3 C per metre above floor level. This figure compares to a typical 2.5 C per metre when using fan heaters. Heater Range and Prices Model kw List Price RP RP Technical Specification Model kw Volts Dimensions(mm) Weight H W D (kg) RP RP RP radiant panels in a changing room making best use of available space 66 web sales@bnthermic.co.uk tel fax

67 RADIANT HEATERS RP radiant panels ceiling mounted in a cricket pavilion RP-06 radiant panels providing an economic and stylish means of heating a flying school in Sussex Radiant ceiling panel providing an almost invisible source of heat in a hospital corridor Control Options and Prices Type Description Model Details List Price Thermostat Standard RST2-IN Page Thermostat Tamperproof RST-TP Page Thermostat Programmable PROSTAT2 Page Timer Programmable PROTIM-7 Page web sales@bnthermic.co.uk tel fax

68 CH Ceramic Heaters Heats people rather than space Direct radiant heating without light output Virtually instant heat ideally suited to irregularly used premises RADIANT HEATERS Typical Applications Community halls Workshops Kennels Zoos Features Aluminium construction with safety grille Long life no glow ceramic heat emitters Wall mounting bracket with up and down and side to side' angle adjustment 1m high temperature cable CH kW Ceramic Heater providing directional radiant heat without light output CH kW Ceramic Heater a few minutes after switching on Heater Range and Prices Model kw List Price CH CH Technical Specification kw Volts Dimensions(mm) Weight (kg) H W D 1.5kw kW A 3kW ceramic heater provides localised heating for visitors to a London craft centre 68 web sales@bnthermic.co.uk tel fax

69 Control Options and Prices Description Model Details List Price Dimmer (3kW max) VR-2 Page Push Button Timer TS-6 Page Movement Sensor WH-402 Page Spot the Iguana! RADIANT HEATERS CH-1500 Ceramic heater providing warmth in a fisherman's cafe Ceramic heater keeping a flower seller warm at a London station web sales@bnthermic.co.uk tel fax

70 RL Replacement Infrared Lamps Please note, we have only listed current BN Thermic heaters. However, we can usually provide replacement lamps for older models as well. Please call us to discuss your replacement lamp requirements. Standard Lamps All lamps 230V 230mm flexible leads with fork terminals Length including ceramic SK15 ceramic caps: 353mm Lamp length RADIANT HEATERS Model kw Colour List Price Each BN Thermic heater Quantity fitted to heater RL15GF 1.5 Gold HN2-1500G 1 HN2-3000G 2 HN2-4500G 3 RL15MF 1.5 Silver HN2-1500M 1 HN2-3000M 2 HN2-4500M 3 RL20GF 2.0 Gold HN2-2000G 1 HN2-6000G 3 RL20MF 2.0 Silver HN2-2000M 1 HN2-6000M 3 Lead length Colour options Gold Silver (Magic Lamp) Fork terminal Weatherproof Lamps (for use in patio heaters) IP55 rated All lamps 230V Overall lamp length: 440mm Flexible tails with plain ferrules Lead length Lamp length Colour options Clear Gold Silver (Magic Lamp) Model kw Colour Lead length (mm) List Price Each BN Thermic heater Quantity fitted to heater RL15CW 1.5 Frosted HWP2-B/W/S 1 RL15GW 1.5 Gold HWP2-45B 1 (centre lamp) RL15MW 1.5 Silver HWP2-BM/WM/ 1 SM RL15GW/3 1.5 Gold 200 & HWP2-3B/W 2 RL15GW/4 1.5 Gold 430 & HWP2-45B 2 (outside lamps) RL20GW 2.0 Gold HWP2-2B/W 1 RL20MW 2.0 Silver HWP2-2BM/WM 1 Light Output Lamp Colour Glow Gold Red Silver Magic Lamp with barely discernible glow (see page 51) Frosted Gold 70 web sales@bnthermic.co.uk tel fax

71 CONTROLS Thermostats A16C - Manual thermostat Application Underfloor heating Adjustable Range +5 C to +30 C (manual adjustment) Mounting Recessed into a single-gang back box Sensors Integral air sensor with floor sensor supplied as standard Switching capacity 15A 230V Voltage supply 230V Contacts Single pole, single throw Dimensions 82mm (H) x 78mm (W) x 17mm (D) - when installed Ingress protection IP20 Special features Manual on/off switch Can be configured for air and floor sensor or floor sensor only List Price U16C - Programmable thermostat Application Adjustable Range Mounting Programming Periods Sensors Switching capacity Voltage supply Contacts Dimensions Ingress protection Special Features Underfloor heating +5 C to +30 C Recessed into a single-gang back box 7-day/4 per day Integral air sensor with floor sensor supplied as standard 15A 230V 230V Single pole, single throw 82mm (H) x 78mm (W) x 17mm (D) - when installed IP20 Can be configured for air and floor sensor or floor sensor only Back-lit screen Summer switch (switches off heating but retains programme) List Price CONTROLS T16R optional IP65 air sensor T16C - Touchscreen programmable thermostat Application Adjustable Range Mounting Programming Periods Sensors Switching capacity Voltage supply Contacts Dimensions Ingress protection Special Features Underfloor heating +5 C to +34 C Recessed into a single-gang back box 7-day with no restriction of number of events per day Integral air sensor with floor sensor supplied as standard 16A 230V 230V Single pole, single throw 90mm (H) x 90mm (W) x 18mm (D) - when installed IP21 Available in white, black or silver Can be configured for air and floor sensor or floor sensor only Screen colour can be changed Built-in energy use monitor Can be used with remote, wall mounted air sensor model T16R (IP65) List Prices T16CW (white): T16CB (black): T16CS (silver): T16R (optional remote air sensor): web sales@bnthermic.co.uk tel fax

72 CONTROLS Thermostats - Continued S16C Smart Thermostat CONTROLS Application App Enabled Adjustable Range Mounting Programmed Periods Sensors Switching Capacity Contacts Ingress protection Dimensions Finish Special Feature Underfloor heating and general space heating Android (4.0 or later) and ios (8.0 or later) +5 C to +35 C Recessed into a single-gang black box days/6 per day Integral air sensor with floor sensor supplied as standard 16A 230V Single pole single-throw IP30 86mm (H) x 130mm (W) x 18mm (D) - when installed S16CW choice of white or brushed chrome S16CB choice of black or black with chrome detail Adjustable screen brightness Automatic screen dimming with adjustable timing List price S16CW (white/chrome): S16CB (black): WST-1 - Wireless thermostat Application Underfloor heating and general commercial and domestic heating Use with WSB-1 relay boxes Adjustable Range +5 C to +37 C Mounting Surface mount or rest on stand provided Programming Periods Weekly in 30 minute periods Sensor Integral air sensor Voltage supply 2 x AAA batteries (provided) Number of WSB-1 relay 4 maximum boxes controlled Ingress protection IP30 Special Features Keyboard lock function Low battery indication Frost protection (holiday) mode Temporary override when used with WSP-1 wireless central programmer List Price WSB-1 - Wireless relay box Application Use with Mounting Sensor Switching capacity Voltage supply Contacts Dimensions Ingress Protection Special features Underfloor heating and general commercial and domestic heating WST-1 wireless thermostat Recessed into a single-gang back box Floor probe (when used with underfloor heating) 16A 230V 230V List Price Single pole, single throw 90mm (H) x 90mm (W) x 24mm (D) - when installed IP20 (see special features) Ingress protecting improved to IP21 when clip provided is fitted 72 web sales@bnthermic.co.uk tel fax

73 WSP-1 - Wireless central programmer new Application Underfloor heating and general commercial and domestic heating Use with WST-1 wireless thermostat and WSB-1 wireless relay boxes Adjustable Range +5 C to +37 C Mounting Recessed into a single-gang back box Programming Periods 7-day with no restriction of number of events per day Voltage supply 230V Dimensions 90mm (H) x 90mm (W) x 18mm (D) - when installed Number of heating 24 maximum zones controlled Ingress protection IP21 Special Features Individual zones (rooms) can be renamed and numbered Frost protection (holiday) mode Energy use monitor List price PROSTAT2 - Programmable thermostat Application Programmable temperature control in commercial premises Programming 7 day or days Adjustable Range +5 C to +35 C Mounting Surface Switching capacity 6A 230V Voltage supply 2 x AA batteries (supplied) Contacts Single pole, change over Dimensions 127mm x 81mm x 28mm Ingress protection IP30 Special features Up to 6 programmable events per day Temporary temperature override until next pre-set period Temperature lock permanent temperature override until reset Delayed start, optimum start, optimum stop options List price CONTROLS RST-TP - Tamperproof thermostat Application Commercial heating Adjustable Range +5 C to +25 C Mounting Surface Switching capacity 20A 230V Voltage supply 230V Contacts Single pole, single throw Dimensions 85mm x 85mm x 35mm Ingress protection IP30 Special features Concealed temperature adjustment Optional shear-off cover fixing screws Heat anticipator improves control accuracy List price web sales@bnthermic.co.uk tel fax

74 RST2-IN - Standard room thermostat Application Commercial heating Adjustable Range +5 C to +30 C Mounting Surface Switching capacity 20A 230V Voltage supply 230V Contacts Single pole, change over Dimensions 85mm x 85mm x 35mm Ingress protection IP30 Special features Heat anticipator improves control accuracy Price RST-HT High Temperature Room Thermostat CONTROLS new Application Commercial and industrial heater control Adjustable Range +5 C to +50 C Mounting Surface mount Switching Capacity 16A 230V Voltage Supply None required Contacts Single pole, single throw Dimensions 125mm x 125mm x 75mm Ingress Protection IP65 List Price FST2-IN - Frost thermostat (indoor) Application Frost protection Adjustable Range -15 C to +10 C Mounting Surface Switching capacity 20A 230V Voltage supply 230V Contacts Single pole, change over Dimensions 85mm x 85mm x 35mm Ingress protection IP30 Special features Heat anticipator improves control accuracy List price FST2-EX - Frost thermostat (outdoor) Application Frost protection Adjustable Range -15 C to +10 C Mounting Surface Switching capacity 20A 230V Voltage supply 230V Contacts Single pole, change over Dimensions 125mm x 125mm x 75mm Ingress protection IP65 Special features Heat anticipator improves control accuracy List Price web sales@bnthermic.co.uk tel fax

75 HC-T2 - Hard Case thermostat Application Heating control in industrial and public areas Adjustable range 12 C to 25 C (comfort) 0 C to 12 C (frost protection) Use internal dip switch to select range Differential Adjustable 0.25 C to 5 C Accuracy To within +/- 0.5 C Mounting Surface Switching capacity 16A 230V Voltage supply 230V Contacts Single pole, changeover Dimensions 120mm x 95mm x 57mm Case Die-cast aluminium Sensor Side mounted black sensor (option of IP55 rated remote mounted sensor HC-S2) Thermostat ingress protection IP30 when installed Special features Tamperproof design requiring HC-D tool to access Vandal resistant List prices Thermostat (HC-T2): Tamperproof tool (HC-D): Optional remote sensor (HC-S2): CONTROLS HC-ST2 - Hard Case thermostat with set-back HC-S2 optional IP55 remote mounted air sensor HC-D tamperproof tool Application Heating control in industrial and public areas Adjustable range 12 C to 25 C (comfort) Adjustable set-back Up to 20 C below comfort setting Indication Set-back operation: Blue LED (default mode) Comfort operation: red LED Comfort selection Side mounted button activating built-in run-down timer (adjustable up to 7.5 hours) OR Remote device such as PROTIM-7 programmable timer Differential Adjustable 0.25 C to 5 C Accuracy To within +/- 0.5 C Mounting Surface Switching capacity 16A 230V Voltage supply 230V Contacts Single pole, changeover Dimensions 120mm x 95mm x 57mm Case Die-cast aluminium Sensor Side mounted black sensor (option of IP55 rated remote mounted sensor HC-S2) Thermostat ingress protection IP30 when installed Special features Tamperproof design requiring HC-D tool to access Vandal resistant List prices Thermostat (HC-ST2): Tamperproof tool (HC-D): Optional remote sensor (HC-S2): web sales@bnthermic.co.uk tel fax

76 CONTROLS Thermostats - Continued TXST-01 - ATEX Thermostat (hazardous gases only) CONTROLS Approval ATEX Equipment Protection Level Gb (gas) Zones Zones 1 and 2 (gas) Group Group IIC Temperature Class T6 Adjustable Range 0 to +40 C Differential 4 C (+/- 2 C) Temperature Sensing Bulb and Capillary (stainless steel) Cable Entries 2 x M20 Enclosure Material Cast aluminium with black anodised finish Mounting plate material Powder coated steel Switching Capacity 16A 230V resistive load Contacts Single pole double throw (changeover) Ingress protection IP66 Dimensions 210mm (w) x 300mm (h) x 91mm (d) Weight 5kg List Price TXST-02 - ATEX Thermostat (hazardous gases and dusts) Approval ATEX Equipment Protection Level Gb (gas) Db (dust) Zones Zones 1 and 2 (gas) Zones 21 and 22 (dust) Group Group IIC (gas) Group IIIC (dust) Temperature Class T6 Adjustable Range -20 to +40 C Temperature Sensing Stainless steel 316Ti capillary Cable Entries 2 x M20 Certified Cable Glands M20 x 1.5 with clamping range Ø 6-13mm M20 x 1.5 with clamping range Ø 7-17mm Enclosure Material Black polyester Switching Capacity 16A 230V resistive load (break on rise/heating) 6A 230V resistive load (make on rise/cooling) Contacts Single pole double throw (changeover) Ingress protection IP65 Dimensions 200mm (w) x 106mm (h) x 90mm (d) Weight 1.2kg List price web sales@bnthermic.co.uk tel fax

77 THT Weatherproof capillary thermostat new Application Control for pipe trace heating Adjustable Range +5 C to +50 C Mounting Surface mount or use THB pipe bracket (see page 17) Switching Capacity 16A 230V Voltage Supply None required Contacts Single pole, single throw Dimensions 125mm x 125mm x 75mm Capillary Length 600mm approx. (including bulb) Ingress Protection IP65 List Price new THTEX ATEX weatherproof capillary thermostat Application Control for pipe trace heating in hazardous areas Equipment Protection Level Gb (gas) Zones Zones 1 and 2 (gas) Group IIC Temperature Class T6 Adjustable Range 0 C to +40 C Mounting Surface mount or use THB pipe bracket (see page 17) Switching Capacity 16A 230V Voltage Supply None required Contacts Single pole, double throw (changeover) Dimensions 130mm x 130mm x 90mm Capillary Length 1600mm approx. (including bulb) Cable Entries 2 x M20 Ingress Protection IP55 List Price CONTROLS web sales@bnthermic.co.uk tel fax

78 CONTROLS Timers TS-5 - Push button timer 6kW CONTROLS Application Mounting Time delay Switching capacity Voltage supply Contacts Dimensions Ingress protection Special features Soft start switching List price Ideal for controlling halogen heaters including patio heaters Surface 5 minutes to 70 minutes 6kW 230V (250W minimum) 230V Single pole, single throw 110mm x 168mm x 80mm IP55 Can be used in conjunction with a programmable timer and/or a thermostat TS-6 - Push button timer - 3kW Application Mounting Time delay Switching capacity Voltage supply Contacts Dimensions Ingress protection Special features Ideal for controlling halogen heaters including patio heaters Surface 2 minutes to 2 hours 16A 230V 230V Single pole, single throw 85mm x 85mm x 67mm IP66 Touch activated Blue light indicates heating off Red light indicates 1minute operation remaining List price PROTIM-7 - Programmable timer Application Programming Mounting Maximum events per day Switching Capacity Voltage Supply Dimensions Ingress Protection Special Features Ideal for use with a variety of commercial and industrial heating schemes 7day, days or 24hour Surface 4 13A 230V (not recommended for direct switching of halogen heaters) 230V 90 x 115 x 57mm IP30 Advance to next programme Boost (select 1 hour or 2 hours) Override permanently on or permanently off Automatic summer update Battery back up Tough aluminium case List price web sales@bnthermic.co.uk tel fax

79 CONTROLS Switches CS-7 - Three gang switch for fan heater control For use with 800 Series SCHG RH SMH CA Settings On/off/high heat/low heat/fan only (summer use) Voltage supply 230V Mounting Surface Dimensions 148 x 88 x 45mm Ingress protection IP30 List price CS-2 - Two gang switch for halogen heater control CONTROLS For use with HN2-3000G/M Settings Full heat/½ heat Voltage supply 230V Mounting Surface Dimensions 85 x 85 x 48mm Ingress protection IP30 List price CS-3 - Three gang switch for halogen heater control For use with HN2-4500G/M HN2-6000G Settings Full heat/⅔ heat/⅓ heat Voltage supply 230V Mounting Surface Dimensions 146 x 85 x 48mm Ingress protection IP30 List price CS-4 - Single gang DP switch for halogen heater control For use with HN2-1500G/M HN2-2000G HN2-3000G/M Settings On/off Voltage supply 230V Mounting Surface Dimensions 85 x 85 x 48mm Ingress protection IP30 List price web sales@bnthermic.co.uk tel fax

80 CONTROLS Switches - Continued CS-5 - Push button For use with MC1 halogen control box Function Triggers MC1 s built-in run-down timer (pre-set between 10 minutes and 140 minutes) Voltage supply 230V Mounting Surface Dimensions 85 x 85 x 48mm Ingress protection IP30 List price CONTROLS CS-6 - Master Switch For use with MC1 halogen control box Function Switches system on and off overrides all controls except frost thermostat Voltage supply 230V Mounting Surface Dimensions 85 x 85 x 48mm Ingress protection IP30 List price OUH2-S Switch for OUH2 industrial fan heater control For use with Any heater or group of heaters from the OUH2 range Settings On/off/fan only (summer use) Voltage supply 230V Mounting Remote surface mounting or mounted onto an OUH2 heater Dimensions 85 x 85 x 48mm Ingress protection IP30 List Price web sales@bnthermic.co.uk tel fax

81 CONTROLS Miscellaneous Controls WH Movement sensor Application Ideal for use with halogen heaters including patio heaters Mounting Surface Switching capacity 16A 230V Voltage supply 230V Sensing range 12m/180 (both distance and angle can be reduced) Time delay 5 seconds to 18 minutes (adjustable) Dimensions 65mm x 83mm x 115mm Ingress protection IP55 List price VR-2 - Dimmer Application Ideal for use with halogen heaters including patio heaters Mounting Surface Output adjustment 30% to 100% Switching capacity 13A 230V (halogen heaters up to 3kW) Voltage supply 230V Contacts Single pole, single throw Dimensions 115mm x 90mm x 58m Ingress protection IP55 Special features Definite click to off List price CONTROLS Contactors CON-32 Model Poles Amps per Pole Max kw per List price CON CON CON ENCL-D Enclosure for CON-32 and CON-50: 175mm x 125mm x 175mm high ENCL-D Enclosure CON-50 CON-80 web sales@bnthermic.co.uk tel fax

82 CONTROLS SystemX CX1 - Controller with thermostat CONTROLS CX1 with thermostat CX2 with tamper resistant thermostat For use with Maximum number of heaters controlled Thermostat range Settings Connection to first heater Mounting Dimensions All heaters in System X range in any sequence 12 0 to 30 C on/off/high heat/low heat/fan only (summer use) Cat5 cable Surface 120mm x 80 x 40mm List price CX2 - Controller with tamper resistant thermostat As CX1 except Thermostat is tamper resistant List price CX3 without thermostat CX3 - Controller without thermostat As CX1 except Without built-in thermostat List price CX6 - Programmable Controller new CX6 Programmable Controller As CX1 except 7 day or days programming Up to 6 programmable events per day Temporary temperature override until next pre-set period Temporary lock permanent temperature override until reset Optimum start for enhanced economy (user selectable) List price CXS - Optional Remote Sensor CXS optional remote sensor for CX1 or CX2 Can be used with CX1 CX2 CX6 When connected overrides built-in sensor List price web sales@bnthermic.co.uk tel fax

83 CASE STUDIES Here are a few projects we have been involved with over the last couple of years. In most cases, we provided a bespoke heating scheme which usually required a site visit. If you would like us to help with your next heating project, just give us a call. St Giles Church - Medbourne 17 x 3kW Halogen Heaters Direct heating was provided by 17 halogen heaters mounted at 3m above floor level. Because halogen heaters are instantly effective, virtually no pre-heating is required and heating costs have been kept to an absolute minimum. CASE STUDIES For this type of project, heater selection and positioning are of paramount importance. BN Thermic engineers are always available to discuss your requirements The Original Factory Shop Llandudno Bay 11 x 4.5kW Surface Mount Ceiling Fan Heaters 6 x 4.5kW Ceiling Grid Fan Heaters 1 x 6kW Overdoor Heater Ceiling heaters were selected for this large two-story retail unit allowing free use of floor and wall space. Where a suspended ceiling had been installed, the heaters could be mounted into the ceiling grid itself. In other areas, we used low-profile surface-mount heaters. The scheme was completed with a 6kW overdoor heater to provide a warm welcome for customers web sales@bnthermic.co.uk tel fax

84 CASE STUDIES - Continued McLaren Workshop West Sussex 3 x Industrial Fan Heaters 2 x Destratification Units This is a large workshop housing a spectacular array of McLaren sports cars. Three industrial fan heaters were installed to maintain a comfortable working temperature for the mechanics during working hours and a background heat to protect the valuable vehicles at other times. A provision was also made for the heaters fans to be switched on in summer months for additional air circulation. CASE STUDIES Two destratification units were installed to enhance economy. These devices are suspended from the roof and recirculate warm air that would otherwise accumulate at high level. It is estimated that the use of destratification units reduces heating bills by approximately 30%. Joules Distribution Centre - Corby 53 x 1.5kW halogen Heaters (Magic Lamp) This distribution centre is far too large to consider installing a conventional heating system. However, there was a requirement to provide instant, direct heat to 53 individual packing stations. BN Thermic surveyed the site and recommended 1.5kW halogen heaters using the latest Magic Lamp technology. These heaters provide all the performance associated with conventional halogen heaters but with the light output reduced to a barely discernible glimmer. 84 web sales@bnthermic.co.uk tel fax

85 Waterloo Station - London 23 x All Black Radiant Heaters The new restaurant and bar facility at Waterloo Station is very stylish and the heaters installed above tables and counters had to match the décor. The sleek modern lines of our all black radiant heaters fitted the bill perfectly. CASE STUDIES Village Hall - Farnham 4 x 2.4kW Radiant Cassettes Radiant cassettes are generally our preferred method of heating village halls and community halls. Their high mounting position allows free use of wall and floor space whilst their noise and draught free operation ensures that the heaters will not interfere with activities such as meetings and coffee mornings. Farnham Village Hall has a fairly low ceiling, allowing the cassettes to be ceiling mounted. In halls with higher ceilings, cassettes are often suspended. For optimum comfort and economy, the correct selection and positioning of radiant cassettes is critical. As was the case at Farnham, a BN Thermic engineer is always available to carry out a free of charge and no obligation survey. Top Golf - Watford 86 x 2kW Black Patio Heaters Top Golf is a terrific facility combining a golf driving range and a lively bar and restaurant. As the golfers wait for their turn to have a few swings, they sit at a high table enjoying waitress service from the bar. Our job was to provide comfort heating that would be effective even on the chilliest of evening. This was achieved by mounting a 2kW patio heater either side of each table. The heaters are fully effective even on a breezy night and economy is ensured by means of time delay control. web sales@bnthermic.co.uk tel fax

86 CASE STUDIES - Continued Bourne House (Serviced and Managed Offices) - Whyteleafe 4 x 1.5kW Silver Patio Heaters 30m² Snow and Ice Meting Cable CASE STUDIES Bourne House recently underwent a major renovation, with work carried out to the very highest standard. Our part in this renovation was to provide heating for an outdoor meeting and smoking area. We specified and supplied heating cable to be installed under the paving slabs. The cable is automatically switched on when there is a risk of snow or ice accumulation thus ensuring safe underfoot conditions. BN Thermic patio heaters were also installed. These stylish silver heaters match the décor of the area perfectly and provide instant, direct heat. The heaters are controlled by movement sensors which keep running costs to a minimum. Spencer Squash Club - Wandsworth 4 x 3.6kW Radiant Cassettes This is a friendly and well-run squash club in South London. The club management contacted us to discuss an economic means of heating their two courts which would not interfere with squash matches or other activities such as mother and toddler groups. We recommended our radiant cassettes. These heaters are mounted at high level and operate silently. They do not produce light output or draughts and are easy to control with a programmable thermostat. School of Dance Croxley 4 x 4.5kW Halogen Heaters 1 x Control Panel Because this relatively large rehearsal space is only used intermittently, conventional space heating was considered to be uneconomic. As an alternative, the school directors were looking for a system that would be instantly effective thus eliminating the need for preheating. The solution was to suspend a grid of four halogen heater from the ceiling. The positioning of the heaters was carefully considered to ensure an even distribution of the radiant effect and control was provided by BN Thermic s MC1 control panel which provides an easy means of adjusting heat intensity. 86 web sales@bnthermic.co.uk tel fax

87 Wagner Hall Theatre - Brighton 9 x 3kW Radiant Cassettes A theatre requires a heating system that is fast acting but does not in any way interfere with performances. This means that heaters producing noise or light are specifically excluded. At Wagner Hall, we deigned a scheme using a grid of six radiant cassettes mounted onto cross beams at high level, augmented by a run of three heaters mounted onto the rear wall using angle-adjustable brackets. Derby Country FC 60 x 3kW Halogen Heaters 10 x Control Panels The management at Derby County were aware that sales from their concourse concessions were suffering because the areas were too cold during the winter months. The concourses are open to the pitch and to the outside world meaning that conventional space heating was impractical. The solution was to provide a grid of halogen heaters at high level, providing instant, direct heat to the Pride Park faithful. A control system was also devised which allowed the stadium manager to adjust heating levels. CASE STUDIES All Saints Church - East Huntspill 45 x Pew Heaters All Saints is a lovely little Somerset parish church. After a site visit, BN Thermic designed a heating scheme using a total of 45 pew heaters. The heaters sit snuggly under the pew seats and with their dark brown paint finish are virtually invisible. Pew heaters are generally the most popular means of church heating not just because they are visually unobtrusive but also because they require virtually no warm up time and are noise and draught free. web sales@bnthermic.co.uk tel fax

88 the brand promise We provide heating systems for just about every commercial and industrial application We are experts in underfloor heating and carry vast stocks Friendly experienced staff are always available to provide technical assistance We offer a free design service We carry out free of charge and no obligation site visits throughout the UK Next day delivery is available for almost all products How to Order BN Thermic products can be ordered from almost all UK electrical wholesalers Visit or call us for details of a wholesaler in your area This price list shows list prices call your preferred wholesaler for your trade price Contact us for technical advice, free designs or detailed quotations BN Thermic Ltd 34 Stephenson Way Crawley West Sussex RH10 1TN Find us on Tel Fax sales@bnthermic.co.uk Web

Product Guide & Price List

Product Guide & Price List the heater people Product Guide & Price List Valid from 1st January 2018 specialists in Commercial and industrial heaters Underfloor heating and Heating cables 2018 Typical heating GARDENS & PATIOS STORE

More information

commercial & industrial electric space heating equipment & controls Electrical Wholesaler Product Guide Valid from 1st February 2011

commercial & industrial electric space heating equipment & controls Electrical Wholesaler Product Guide Valid from 1st February 2011 commercial & industrial Electrical Wholesaler Product Guide Valid from 1st February 2011 electric space heating equipment & controls 2011 Commercial and In Catalogue Valid from 1st February 2011 The BN

More information

CERTIFIED UNDERFLOOR HEATING WITH 15 YEARS GUARANTEE

CERTIFIED UNDERFLOOR HEATING WITH 15 YEARS GUARANTEE Electric underfloor heating Simple to install Cheap to install Simple to regulate Safe to use Maintenance free CERTIFIED UNDERFLOOR HEATING WITH 15 YEARS GUARANTEE WHY CHOOSE HEATCOM? Heatcom is a leading

More information

F1202 TRACE HEATING. Road & Ramp

F1202 TRACE HEATING. Road & Ramp Trace Heating Specialists Road & Ramp ROAD & RAMP HEATING ESH Trace Heating Ltd provide a comprehensive range of products to prevent the settlement of snow and formation of ice on roads, ramps and stairs.

More information

Polymer solutions Heating mat EM2-CM

Polymer solutions Heating mat EM2-CM 1.5 Polymer solutions 1. Application EM2-CM is a constant wattage heating mat for simple, fast, and effective ramp and accessway heating to prevent snow and ice formation. The EM2-CM mat is particularly

More information

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes WARM WATER UNDERFLOOR HEATING SYSTEMS Guidance Notes 02 WARM WATER UNDERFLOOR HEATING SYSTEMS Introduction Underfloor heating systems consist of a series of pipes which are integrated into the floor structure

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 220533 - HEAT TRACING FOR PLUMBING PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes plumbing piping heat tracing for freeze prevention, domestic hot-water-temperature maintenance, and

More information

OneZone. Underfloor heating range. For existing properties & new build extensions. Extensions Conservatories Single rooms HEAT PUMPS

OneZone. Underfloor heating range. For existing properties & new build extensions. Extensions Conservatories Single rooms HEAT PUMPS Extensions Conservatories Single rooms OneZone Underfloor heating range For existing properties & new build extensions UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL Contents Warm water underfloor heating

More information

First Trace Heating Product Details

First Trace Heating Product Details First Trace Heating Product Details and specifying guide Contents 2 4 6 9 9 10 Refrigeration Safe Trace Product Diagrams 11 Components www.first-traceheating.co.uk Introduction Specification Maximum Exposure

More information

radiant floor heating Floor Heating Mats Floor Heating Cables Thermostats

radiant floor heating Floor Heating Mats Floor Heating Cables Thermostats radiant floor heating Floor Heating Mats Floor Heating Cables Thermostats Radiant floor heating: A modern comfort solution Floor heating s vertical temperature distribution is the closest form of heating

More information

electric floor heating Heating mats Heating cables Temperature controllers

electric floor heating Heating mats Heating cables Temperature controllers electric floor heating Heating mats Heating cables Temperature controllers Floor heating as the most favourable heating solution Of all heating systems, floor heating s vertical temperature distribution

More information

electric floor heating for everyone Heating mats Heating cables Temperature controllers

electric floor heating for everyone Heating mats Heating cables Temperature controllers electric floor heating Heating mats solutions for everyone Heating cables Temperature controllers Floor heating as the most favourable heating solution Of all heating systems, floor heating s vertical

More information

electric floor heating Heating mats Heating cables Temperature controllers

electric floor heating Heating mats Heating cables Temperature controllers electric floor heating Heating mats Heating cables Temperature controllers Floor heating as the most favourable heating solution Of all heating systems, floor heating s vertical temperature distribution

More information

The CAB & DAB Air Curtains

The CAB & DAB Air Curtains The CAB & DAB Air Curtains Frequently Asked Questions General Positioning Page 2 Electrical & Connection Page 4 Electric Heated Page 5 Electronic door triggered shutdown feature (Electric) Page 5 Electronic

More information

amuheat Cable Mat floor heating systems Installation Manual CM02-12

amuheat Cable Mat floor heating systems Installation Manual CM02-12 amuheat floor heating systems Cable Mat Installation Manual CM02-12 Table of Contents Introduction 1 2 Cable Mat Important Installation Guidelines Tools & Materials Needed for Installation Kit Contents

More information

Freezer Frost Heave Prevention

Freezer Frost Heave Prevention Freezer Frost Heave Prevention 1. Pipe Freeze Protection and Flow Maintenance RaySol System Mineral Insulated Heating Cable System This step-by-step design guide provides the tools necessary to design

More information

UNDERWOOD HEATING SYSTEM

UNDERWOOD HEATING SYSTEM INSTALLATION MANUAL Suitable for most wooden/laminate fl oors (always check with fl oor manufacturer) Ideal for most wood/laminate fl oors Easy to install Fully compliant to latest regulations CE approved

More information

protection Constant wattage heating cables Self-regulating heating cables Temperature controllers

protection Constant wattage heating cables Self-regulating heating cables Temperature controllers snow & ice protection Constant wattage heating cables Self-regulating heating cables Temperature controllers Protection of roofs, gutters and downpipes Snow and ice protection systems protect against:

More information

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10

Danfoss Self-limiting Heating Cables SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10 MAKING MODERN LIVING POSSIBLE Installation Guide SLPG-10/26/33, SLPG-18, SLHW-55/70, SLPH-10 www.eh.danfoss.com Table of Contents 1 Introduction............................................. 3 1.1 Self-limiting

More information

Installation Guide. Heating cables. Thin concrete (< 3 cm) Intelligent solutions with lasting effect. Visit DEVI.com

Installation Guide. Heating cables. Thin concrete (< 3 cm) Intelligent solutions with lasting effect. Visit DEVI.com Installation Guide Heating cables Thin concrete (< 3 cm) Intelligent solutions with lasting effect Visit DEVI.com Table of contents 1 Introduction.................... 2 1.1 Safety Instructions...............2

More information

Always make sure to check the heating film before, during, and after installation of the floor covering.

Always make sure to check the heating film before, during, and after installation of the floor covering. Installation of floor heating film for ceramic tiles, granite and other stone or composite flooring Read through this entire manual before starting installation. All electrical connections must be made

More information

Toll Free:

Toll Free: 1 ProLine s electric radiant floor heating system is one of the most popular and durable floor heating solutions on the market. Available pre-spaced in mats with an adhesive backing or on the spool, the

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Unit 1 79 Friar Street Worcester WR1 2NT Tel: 01905 616 928 Fax:01905 611 240 E-mail: info@underfloorheatingsystems.co.uk Website: www.underfloorheatingsystems.co.uk ngsystems.co.uk

More information

Anti frost. Snow Melting USA 2012 USA 2014

Anti frost. Snow Melting USA 2012 USA 2014 Anti frost USA 2014 USA 2012 1 Mat Resistance Wires Reinforced Braide PVC Jacketing Super strong aramid FEP Mat DomoTecK s Mat is the ideal heating element for outdoor de-icing. Our snow melting mat prevents

More information

Carbon Film Installation Instructions

Carbon Film Installation Instructions Contents Page 2 Page 3 Page 4 Page 5 Page 8 Product Overview Pre-Installation & Electrical Provision Depron Underlay Installation Carbon Film Installation - Under Wood/Laminate Flooring Notes & Trouble

More information

CoziMat. 1. Introduction and Brief Description COZIMAT INSTALLATION INSTRUCTIONS & SAFETY REQUIREMENTS

CoziMat. 1. Introduction and Brief Description COZIMAT INSTALLATION INSTRUCTIONS & SAFETY REQUIREMENTS CoziMat 1. Introduction and Brief Description The CoziMat underfloor heating mat is designed for underfloor heating of rooms where the floor thickness needs to be kept to a minimum. CoziMat underfloor

More information

Installing Underfloor Heating Film. 1. Layout of electric underfloor heating systems

Installing Underfloor Heating Film. 1. Layout of electric underfloor heating systems Read through this entire manual before starting installation. May be installed under laminate, engineered wood or approved hardwood floors. See flooring manufacturer s specifications and instructions.

More information

IMPORTANT NOTES. Electric Underfloor Heating Mats For use with Touchsceen underfloor heating Thermostat

IMPORTANT NOTES. Electric Underfloor Heating Mats For use with Touchsceen underfloor heating Thermostat For any assistance or further information, go online at bathstore.com Electric Underfloor Heating Mats For use with Touchsceen underfloor heating Thermostat - 61000012339 Model Dimensions Area Covered

More information

Underwood Heater Installation Manual

Underwood Heater Installation Manual Underwood Heater Installation Manual Contents Important Safeguards and Warnings... 3 1 General Information... 3 1.1 Use of the Manual... 3 1.2 Safety Guidelines... 3 1.3 Remember to measure resistance...

More information

Installation Guide - Heating Cables. Installation Guide. Heating cables. for In-Slab and In-Screed Applications BROCDEV135.1

Installation Guide - Heating Cables. Installation Guide. Heating cables. for In-Slab and In-Screed Applications BROCDEV135.1 - Installation Guide Heating cables for In-Slab and In-Screed Applications BROCDEV135.1 Table of Contents SECTION TITLE PAGE 1. Introduction... 3 2. Cable and Application Overview... 4 3. Safety Instructions...

More information

Installation Guide. Heating cables. Pipe tracing. Intelligent solutions with lasting effect. Visit DEVI.com

Installation Guide. Heating cables. Pipe tracing. Intelligent solutions with lasting effect. Visit DEVI.com Installation Guide Heating cables Pipe tracing Intelligent solutions with lasting effect Visit DEVI.com Table of Contents 1 Introduction.................... 3 1.1 Safety Instructions...............3 1.2

More information

Underlaminate Foil Heater

Underlaminate Foil Heater Installation Manual: Underlaminate Foil Heater TECHNICAL HELPLINE 0845 345 2288 n online at warmup.co.uk IMPORTANT Read this manual before attempting to install your foil heater. Incorrect installation

More information

INSTALLATION INSTRUCTIONS ONE LARGE ZONE

INSTALLATION INSTRUCTIONS ONE LARGE ZONE INSTALLATION INSTRUCTIONS ONE LARGE ZONE Unit 1 79 Friar Street Worcester WR1 2NT Tel: 01905 354 791 Fax: 01905 352 100 E-mail: info@underfloorheatingsystems.co.uk Website: www.underfloorheatingsystems.co.uk

More information

Carbon Heating Film. Failure to follow these instructions may result in fire, electrical shock, property damage, personal injury, or death.

Carbon Heating Film. Failure to follow these instructions may result in fire, electrical shock, property damage, personal injury, or death. Carbon Heating Film Easy to install. Does not circulate pollutants, dust, dirt, allergens or dry air. May be installed on wall, ceiling, under laminate, engineered wood floors or tile. Brings soothing

More information

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological

Hot water temperature maintenance. Less water volume and less heat loss in the pipe work help prevent bacteriological Providing the comfort of instant hot water is the key requirement of any modern hot water system. The Raychem single-pipe system keeps water at the right temperature in a building s water distribution

More information

Underfloor Heating Inscreed Cable System

Underfloor Heating Inscreed Cable System The world s best-selling floor heating brand Installation Manual: Underfloor Heating Inscreed Cable System TECHNICAL HELPLINE 085 5 2288 IMPORTANT Read this manual before attempting to install your inscreed

More information

Pipe Freeze Protection. Flow Maintenance. Introduction. XL-Trace System

Pipe Freeze Protection. Flow Maintenance. Introduction. XL-Trace System Pipe Freeze Protection and Flow Maintenance 1. Pipe Freeze Protection and Flow Maintenance Introduction XL-Trace System This step-by-step design guide provides the tools necessary to design a Raychem XL-Trace

More information

Installation Guide For your AHT Underfloor Heating System

Installation Guide For your AHT Underfloor Heating System Installation Guide For your AHT Underfloor Heating System Dear AHT Customer, Thank you for choosing the AHT underfloor heating system. It is designed to be simple to install and cost efficient to operate.

More information

XL-Trace System Application and Design Guide

XL-Trace System Application and Design Guide R XL-Trace System Application and Design Guide Pipe Freeze Protection and Flow Maintenance for Commercial Construction Applications Pipe Freeze Protection and Flow Maintenance 1. Pipe Freeze Protection

More information

Instruction Manual WARNINGS

Instruction Manual WARNINGS Instruction Manual LARGE COMMERCIAL RECESSED AIR CURTAIN HSACR9000, 12000 & 18000 ELECTRICALLY HEATED RECESSED AIR CURTAINS WITH ENERGY SAVING CONTROLS INSTALLATION AND OPERATING MANUAL INDEX Section General

More information

Air circulation. Xpelair air circulation products are able to provide for your fixed or spot cooling needs throughout the year.

Air circulation. Xpelair air circulation products are able to provide for your fixed or spot cooling needs throughout the year. Air circulation Xpelair air circulation products are able to provide for your fixed or spot cooling needs throughout the year. At work employers are legally obliged to ensure that during working hours

More information

Wall, Ceiling and Floor Heaters. Commercial & Industrial Electric heating and controls

Wall, Ceiling and Floor Heaters. Commercial & Industrial Electric heating and controls Wall, Ceiling and Floor Heaters Commercial & Industrial Electric heating and controls Our products do more in a wide range of applications. Expect More. Introduction INDEECO offers commercial and industrial

More information

Foil Heaters. Installation Manual: TECHNICAL HELPLINE

Foil Heaters. Installation Manual: TECHNICAL HELPLINE Installation Manual: Foil Heaters TECHNICAL HELPLINE 0345-345-2288 Complete and submit the warranty form online at www.warmup.co.uk IMPORTANT Read this manual before attempting to install your foil heater.

More information

Underfloor Heating Mat Installation Manual

Underfloor Heating Mat Installation Manual Affordable Underfloor Heating Underfloor Heating Mat Installation Manual Technical Helpline 0845 034 8272 www.sunstone.co.uk 1 SunStone Mat Manual V3.1.indd 1 09/01/2015 13:58:26 DO S & DON TS ENSURE CORRECT

More information

The Professionals Choice

The Professionals Choice Product Range Brochure The Professionals Choice Lifetime Warranty Electric Underfloor Heating Ice & Snow Melting Welcome to Heat Mat We manufacture electric underfloor heating for retrofit, refurbishment

More information

Gardian W51. Approvals

Gardian W51. Approvals Gardian W51 120 V pre-assembled electric heating cables for pipe freeze protection and roof & gutter de-icing Installation Instructions Description Gardian W51 120 V pre-assembled self-regulating heating

More information

CASE STUDY UNDER FLOOR HEATING. Electric Underfloor Heating Display Stand

CASE STUDY UNDER FLOOR HEATING. Electric Underfloor Heating Display Stand CASE STUDY UNDER FLOOR HEATING Electric Underfloor Heating Display Stand 58 & MIRROR DEMISTERS 60 BENEFITS & FEATURES OF UFH 64 THERMOSTATS 62 THERMAL INSULATION BOARD 66 MIRROR DEMISTERS 63 HEATING MATS

More information

The Professionals Choice

The Professionals Choice The Professionals Choice Product Range Brochure & List 2017 Lifetime Warranty Electric Underfloor Heating Ice & Snow Melting Welcome to Heat Mat We manufacture electric underfloor heating for retrofit,

More information

3000 Series Fan Forced Ceiling Heater Series Commercial Fan Forced Ceiling Heater

3000 Series Fan Forced Ceiling Heater Series Commercial Fan Forced Ceiling Heater Selectable Wattages, Back Cans, And Power Disconnects Furnish and install Electric Forced Air Heaters, Series 3380 where specified. The heaters shall be constructed of a heavy gauge steel housing. The

More information

LIFETIME. INSTALLATION MANUAL emat Pro 100w/150w/200w WARRANTY

LIFETIME. INSTALLATION MANUAL emat Pro 100w/150w/200w WARRANTY INSTALLATION MANUAL emat Pro 100w/150w/200w LIFETIME WARRANTY Before you begin installing, read through these instructions carefully and check that you have all the components required. 01473 276677 www.elementsunderfloorheating.co.uk

More information

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater Toll-Free: 1-800-462-4983 Hazardous Location Fan Forced Unit Heater 3-25KW for Class I, Group C & D, Division 1 & 2 and Class II, Groups E, F & G, Divisions 1 & 2. Designed for rugged industrial applications

More information

AKOCable Heating Cable Solutions Electrical Tracing

AKOCable Heating Cable Solutions Electrical Tracing Heating Cable Solutions Electrical Tracing HEATING CABLE TECHNOLOGIES Mineral insulation Series type heating cable Used for high temperature maintenance and/or exposure Fluoropolymer cover Used in long

More information

EN-SUITE & KITCHEN HEATING

EN-SUITE & KITCHEN HEATING EN-SUITE & KITCHEN HEATING 64 ELECTRIC UNDER FLOOR HEATING 70 HEATED TOWEL RADIATORS 74 MIRROR DEMISTERS ELECTRIC UNDERFLOOR HEATING Electric Under Floor Heating It s like walking on Sunshine Comfort electric

More information

Uponor Comfort E AL-Foil Mat

Uponor Comfort E AL-Foil Mat Uponor Comfort E AL-Foil Mat Contents Important notes on the intended use, safety and warranty...3 Intended use...3 Uponor Declaration of Warranty...3 System description...4 Floor construction...4 Technical

More information

CASSETTE UNIT. Comfort Circle

CASSETTE UNIT. Comfort Circle CASSETTE UNIT Comfort Circle Comfort Circle cassette unit All-round comfort With today's energy prices, building owners are increasingly aware of the need for an efficient climate system to heat or cool

More information

INSTALLATION INSTRUCTIONS SINGLE CIRCUIT

INSTALLATION INSTRUCTIONS SINGLE CIRCUIT INSTALLATION INSTRUCTIONS SINGLE CIRCUIT Unit 1 79 Friar Street Worcester WR1 2NT Tel: 01905 616 928 Fax:01905 611 240 E-mail: info@underfloorheatingsystems.co.uk Website: www.underfloorheatingsystems.co.uk

More information

emat Pro 100/150/200 Installation Manual

emat Pro 100/150/200 Installation Manual emat Pro 100/150/200 Installation Manual www.electricunderfloorheating.co.uk Before you begin installing read through these instructions carefully and check that you have all the components required. Introduction

More information

ELECTRIC HEATING THERMOSYSTEM

ELECTRIC HEATING THERMOSYSTEM ELECTRIC RADIANT MAT 8200E INSTALLATION AND USE MANUAL heating passion ELECTRIC HEATING THERMOSYSTEM WARNING: For the guarantee to be valid, the product must be installed and handled as indicated in this

More information

Data Sheet. Self regulating process heating tapes RS stock numbers ,

Data Sheet. Self regulating process heating tapes RS stock numbers , Data Pack K Issued March 1997 232-3333 Data Sheet Self regulating process heating tapes RS stock numbers 379-889, 379-974 The information contained within this sheet regarding applications and installation

More information

Heating cable solutions for temperature-related problems

Heating cable solutions for temperature-related problems Heating cable solutions for temperature-related problems EasyHeat Residential and Commercial Solutions Depend on EasyHeat products for proper pipe temperatures, free-flowing roof gutters, safer walkways

More information

Overview Frost Heave Prevention for Freezer floors on ground.

Overview Frost Heave Prevention for Freezer floors on ground. PLEASE NOTE The floor sensor MUST be installed such that it may be REMOVED for service if required! The sensor probe should be installed into a conduit with no more than one wide-angle bend. This should

More information

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING RADIANT PANELS COMMERCIAL BUILDINGS A guide to Radiant Panels, including our unique product range, consultancy service and accessories. INNOVATIVE VENTILATION & HEATING www.pricetwa.co.uk FLEXIBLE, INTEGRATED

More information

AKOCABLE Heating Cable Solutions Electrical Tracing

AKOCABLE Heating Cable Solutions Electrical Tracing AKOCABLE Heating Cable Solutions Electrical Tracing www.ako.com AKOCABLE HEATING CABLE TECHNOLOGIES Mineral insulation Series type heating cable Used for high temperature maintenance and/or exposure Fluoropolymer

More information

Tubular Industrial Process

Tubular Industrial Process Application Tempco Over-the-Side Immersion Heaters are specifically designed for heating fluids in tanks. Depending on the tank shape, size, accessibility and working area inside the tank, choose a round

More information

Classic Mats Installation Manual

Classic Mats Installation Manual Classic Mats Installation Manual 1 Classic Mats WarmTouch Classic Mats are the ideal Electric floor warming systems, designed by DomoTecK, for installation under tile, stone or marble. WarmTouch Classic

More information

Carat. Chilled beams. Use. Worth noting. Installation. Key figures. lindab chilled beams

Carat. Chilled beams. Use. Worth noting. Installation. Key figures. lindab chilled beams 22 Use Lindab's chilled beam supplies cooling with a low air velocity to the room below. It offers many possibilities and great flexibility. For example, it is possible to paint any color you want. Installation

More information

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

INSTALLATION, INSTRUCTION AND SERVICE MANUAL TUNGSTEN SMART-HEAT ELECTRIC HEATER BY BROMIC INSTALLATION, INSTRUCTION AND SERVICE MANUAL SUITABLE FOR ELECTRIC HEATER MODELS: TUNGSTEN 2000W, 3000W, 4000W- AND TUNGSTEN 6000W Version 1.7 USA! IMPORTANT

More information

Data Sheet. Self regulating heating tapes. RS stock numbers

Data Sheet. Self regulating heating tapes. RS stock numbers Data Pack K Issued September 2001 232-3125 Data Sheet Self regulating heating tapes RS stock numbers 379-312 The information contained within this sheet regarding applications and installation of RS WinterGard

More information

tungsten Smart-heat electric heater

tungsten Smart-heat electric heater tungsten Smart-heat electric heater BY BROMIC Installation, instruction and service manual SUITABLE FOR electric HEATER MODELS: tungsten 2000w, 3000W, 4000W- AND tungsten 6000w Version 1.5 USA! IMPORTANT

More information

Simple. Smart. Solutions. ROOM PACK Z2105/239/0812. Step by Step Installation Guide

Simple. Smart. Solutions. ROOM PACK Z2105/239/0812. Step by Step Installation Guide Simple. Smart. Solutions. ROOM PACK Z2105/239/0812 Step by Step Installation Guide 1. Room Pack Overview 2. Temperature Settings 3. Operation 4. Wiring 5. Installing Your Room Pack Before you get started

More information

Modula Standard Performance

Modula Standard Performance the future of space conditioning Modula Standard Performance heating panel Application Commercial, hospitals, hotels, schools, shops, sports halls, offices, laboratories, food industry etc. Installation

More information

CF1 ProVector Explosion-Proof Heaters

CF1 ProVector Explosion-Proof Heaters CF1 ProVector Explosion-Proof Heaters The CF1 Series ProVector Explosion-proof convection heater offers the most reliable, dependable and trouble-free service available for heating hazardous locations

More information

ELEKTRA RadiantFloor Heating

ELEKTRA RadiantFloor Heating www.elektra.eu ELEKTRA RadiantFloor Heating single-side powered MD Heating Mats Installation manual ELEKTRA Heating Mats For the proper installation and operation of the ELEKTRA radiant floor heating system,

More information

Principle of Operation:

Principle of Operation: SELF-REGULATING HEATERS Standard Overjacket Standard Metal Braid Stranded Copper Conductors Self Regulating Conductive Core Thermoplastic Elastomer Jacket Description: Nelson Type CLT selfregulating heater

More information

The Professionals Choice

The Professionals Choice The Professionals Choice Product Range Brochure & Price List 2018 For Lot 20 compliant thermostats see pages 17-23 Best Customer Service Best Overall Supplier Lifetime Warranty Electric Underfloor Heating

More information

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING

RADIANT PANELS COMMERCIAL BUILDINGS INNOVATIVE VENTILATION & HEATING RADIANT PANELS COMMERCIAL BUILDINGS A guide to Radiant Panels, including our unique product range, consultancy service and accessories. INNOVATIVE VENTILATION & HEATING www.pricetwa.co.uk FLEXIBLE, INTEGRATED

More information

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

INSTALLATION, INSTRUCTION AND SERVICE MANUAL COBALT SMART-HEAT ELECTRIC HEATER BY BROMIC INSTALLATION, INSTRUCTION AND SERVICE MANUAL SUITABLE FOR ELECTRIC HEATER MODELS: COBALT 2000W, 3000W, 4000W- AND COBALT 6000W Version 1.0 USA! IMPORTANT READ

More information

quality european heating appliances

quality european heating appliances Superb Comfort in every room of your home quality european heating appliances AUSTRALIA Ph:03 9852 9599 www.atlantics.com.au ss@atlantics.com.au S4/13-25 Church Street Hawthorn 3122 Victoria Australia

More information

DOMOTHERM CLASSIC TWIN/S MAT

DOMOTHERM CLASSIC TWIN/S MAT Floor warming products 2013 V 10.12.2012 DOMOTHERM CLASSIC TWIN/S MAT An ideal solution for the whole house Ultra thin cable (2mm) Energy efficient Easy to install Domotherm Twin/s can be installed under:

More information

JH Series Installation

JH Series Installation JH Series Installation Space Heating / Fresh Air Make-Up From the Manufacturers of Hi-Velocity Systems TM Includes: JH-15 JH-30 Module-JH-Series-Installation-Manual-010118 Installation JH fan coils by

More information

Installation & Service Manual. Models ALF 20, 30, 40, 50, 60, 80

Installation & Service Manual. Models ALF 20, 30, 40, 50, 60, 80 Installation & Service Manual Models ALF 20, 30, 40, 50, 60, 80 IMPORTANT! Read all safety instructions before installing, using, or servicing the heater. Installation & servicing should only be carried

More information

Wall Panelling. Finishing Touches. Accessories. Wall panelling See Page 170

Wall Panelling. Finishing Touches. Accessories. Wall panelling See Page 170 Wall Panelling Finishing Touches Accessories Wall panelling See Page 170 154 FINISHING TOUCHES With attention to detail, you can transform a stylish bathroom design into something truly special. You could

More information

Recessed. Air Curtain. Fig 1. Recessed air curtain

Recessed. Air Curtain. Fig 1. Recessed air curtain the future of space conditioning recessed www.frenger.co.uk an FTF Group Company Recessed Introduction These recessed s create an air barrier, which helps to prevent cold draughts thus creating a comfortable

More information

Model Dimensions Coverage 230v 230Vac. Pack Contents. Measuring Up

Model Dimensions Coverage 230v 230Vac. Pack Contents. Measuring Up Installation and Operating Instructions Electric tile-warming system Model Dimensions Coverage Wattage @ 230v Amps@ 230Vac RTS1M 2.0m x 0.5m 1.0m 2 160W 0.70A RTS1.5M 3.0m x 0.5m 1.5m 2 240W 1.04A RTS2M

More information

Nu-Heat. SPECIFYING NU-HEAT LoPro Max. A Best Practice Guide for professional installers

Nu-Heat. SPECIFYING NU-HEAT LoPro Max. A Best Practice Guide for professional installers Nu-Heat UNDERFLOOR & RENEWABLES SPECIFYING NU-HEAT LoPro Max A Best Practice Guide for professional installers UNDERFLOOR HEATING GROUND SOURCE HEAT PUMPS AIR SOURCE HEAT PUMPS SOLAR THERMAL V1 WWW.NU-HEAT.CO.UK

More information

Hazardous Area Portable Fan Heater The Bulldog

Hazardous Area Portable Fan Heater The Bulldog Hazardous Area Portable Fan Heater The Bulldog www.exheat-industrial.com MFH The Bulldog Portable Fan Heater EXHEAT Industrial s MFH The Bulldog Portable Fan Heater is the world s first truly portable

More information

COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS

COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS INDUSTRIAL AIR AND INFRARED RADIANT HEATERS Portable Unit Heaters Portable electric heaters are available in radiant-heat or fan-forcedair designs.

More information

LIFETIME. INSTALLATION MANUAL efoil WARRANTY

LIFETIME. INSTALLATION MANUAL efoil WARRANTY INSTALLATION MANUAL efoil LIFETIME WARRANTY Before you begin installing, read through these instructions carefully and check that you have all the components required. 01473 276677 www.elementsunderfloorheating.co.uk

More information

Fire Sprinkler Freeze Protection Design / Install Guide

Fire Sprinkler Freeze Protection Design / Install Guide Fire Sprinkler Freeze Protection Design / Install Guide Page 1 of 23 Fire Sprinkler System Freeze Protection Design / Install Guide CONTENTS Introduction Page 3 System Overview Page 4 Fire Suppression

More information

OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor (THS-A) EUROPE. The modern, slimline solution for

OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor (THS-A) EUROPE. The modern, slimline solution for I N D O O R R A D I A N T S T R I P H E A T E R S OPERATION, INSTALLATION AND MAINTENANCE MANUAL H E AT S T R I P Indoor (THS-A) EUROPE The modern, slimline solution for l o w c o s t, e ff i c i e n t

More information

field tested in some of the most demanding environments, CHR s specialized heating units are Built rugged and designed to last.

field tested in some of the most demanding environments, CHR s specialized heating units are Built rugged and designed to last. field tested in some of the most demanding environments, CHR s specialized heating units are Built rugged and designed to last. Custom Heaters & Research is the industrial division of CHR Inc. which began

More information

Electric Floor Warming Systems Installation and Operation Instructions. Mat Heating Systems and Cable Heating Systems. UL Listed for USA and Canada

Electric Floor Warming Systems Installation and Operation Instructions. Mat Heating Systems and Cable Heating Systems. UL Listed for USA and Canada Electric Floor Warming Systems Installation and Operation Instructions Mat Heating Systems and Cable Heating Systems UL Listed for USA and Canada Thank you for your purchase of a Warming Systems electric

More information

CX1 ProVector Explosion-Proof Heaters

CX1 ProVector Explosion-Proof Heaters Explosion-Proof Heaters For hazardous locations heating, rely on the for the most dependable, troublefree service available. CCI Thermal Technologies Inc. manufactures explosion-proof air heaters to satisfy

More information

SELF-REGULATING PIPE TRACING HEATER CABLE

SELF-REGULATING PIPE TRACING HEATER CABLE SELF-REGULATING PIPE TRACING HEATER CABLE Installation & Operation Manual TABLE OF CONTENTS GENERAL INFORMATION... 1 How Heating Systems Work...1 PRODUCT SELECTION... 1 RECEIPT & STORAGE... 1 Receipt...1

More information

tungsten Smart-heat electric heater

tungsten Smart-heat electric heater tungsten Smart-heat electric heater BY BROMIC Installation, instruction and service manual SUITABLE FOR electric HEATER MODELS: tungsten 2000w, 3000W, 4000W- AND tungsten 6000w Version 1.4 USA! IMPORTANT

More information

Heating Tapes/Mats HEATING TAPES HEATING CORDS HEATING MATS DRUM HEATERS GREAT FOR HEATING SMALL TUBES! MOISTURE RESISTANT!

Heating Tapes/Mats HEATING TAPES HEATING CORDS HEATING MATS DRUM HEATERS GREAT FOR HEATING SMALL TUBES! MOISTURE RESISTANT! S E L E C T I O N G U I D E Heating Tapes/Mats OUR GREATEST VARIETY GREAT FOR HEATING SMALL TUBES! MOISTURE RESISTANT! OUR BEST SELLING DRUM HEATERS! HEATING TAPES Temperature Requires Range External Built-in

More information

Underfloor Heating Cable Installation Manual

Underfloor Heating Cable Installation Manual Affordable Underfloor Heating Underfloor Heating Cable Installation Manual Technical Helpline 0845 034 8272 www.sunstone.co.uk SunStone Wire Manual V3.1.indd 1 09/01/2015 14:00:49 BEFORE YOU BEGIN INSTALLATION...

More information

Documentation. Parallel Heating Cable. Type: ELP

Documentation. Parallel Heating Cable. Type: ELP Documentation Parallel Heating Cable Type: ELP 05.01.2018 K. Folkerts Content 1. Data sheet 2. Installation instructions 3. Declarations of conformity 05.01.2018 K. Folkerts 1 05.01.2018 K. Folkerts Constant

More information

15KW ELECTRIC FAN HEATER

15KW ELECTRIC FAN HEATER 15KW ELECTRIC FAN HEATER MODEL NO: DEVIL 7015 PART NO: 6935456 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use this product,

More information

Convector Heater G2CH. 2.0kW. 3 Power settings. Fully adjustable thermostat. Wall mounting option. Illuminated control switch. Fitted with 1.

Convector Heater G2CH. 2.0kW. 3 Power settings. Fully adjustable thermostat. Wall mounting option. Illuminated control switch. Fitted with 1. Oil Radiators Convector Heater Downflow Bathroom Heater G20FH7 G2CH G2BFHT2 1.5 kw 2.0kW 2kW 7 Fin radiator 3 Power settings Pull cord adjust heat settings 3 Heat settings Fully adjustable thermostat for

More information