1 WINE CELLAS AI CONDITIONES SPC EVPL GENESIS-VINTAGE SPLIT SYSTEMS Make your cellar an underground Paradise Pour la la CAVE
2 SPLIT systems Five stars air conditioning Over the years Friax Industry has expanded its range to offer the ultimate in wine cellar air conditioners: 5 stars air conditioning Friax cellar air conditioners adjust your cellar conditions to wine storage requirements. Constant temperature, the key to preservation. Sudden changes in temperature can damage wine, leading to random aging or even the irreversible deterioration of the bottles. The basic function of Friax splits is to achieve temperature stability by cooling or warming the cellar(depends of models). Suitable humidity. Dry air is bad for wine storage. It dries the corks, causing the wine to seep out. The air entering the bottle can cause maderization and irretrievable loss of flavor. Excess moisture can cause labels to deteriorate and peel off, reducing the value of precious bottles. The Friax Cold Water ecycling (CW) process matains the humidity level in the cellar at an ideal range. Overly damp cellars are dried. For dry cellars, Vintage model include HG% that increase the humidity without heating or any treatment on water Vibration-free. Vibrations are detrimental to wine, it's that simple! Friax machines are equipped with their own anti-vibration base including a double barrier of shock absorbers for the compressor. The inner tubing is designed to eliminate the transmission of vibration from refrigerant pipes to the cellar. Flawless regulation. The aestheticism of wireless controller associated to the last control technologies make Friax as a leader in the wine cellar field Easy to install, adaptable products. Thanks to its extensive range, Friax is appropriate for most home installations. You will always find the appropriate solution for your configuration with our air or water condensing units, and ceiling, wall-mounted or ducted evaporators. KPM accessory
3 Wireless controller SF The controller includes 1 wireless controller with digital display backlit, wall mounting 1 remote support 1 junction box incorporating a power board and card communication radio frequency 1 temperature sensor NTC condenser 1 cellar temperature sensor for Genesis Model 1 cellar temperature /hygrometry sensor for Vintage model 1 J45 Patch Cable 5m for connecting the cellar probe Controller specification Junction Box. ON / OFF Front. Operation indicators and alarms. 230 V. Compressor relay. Evaporator fan relay with control 0-10V speed on EC motors. Condenser fan relay with control 0-10V speed on C motors. Self-adaptation of the split configuration and to the type of motor and evaporator unit (AC or EC). Management of the compressor heater with optimizing all seasons even when the appliance is switched off with the remote control. Pump Down on selected models. NO/NC Alarm contact. Black ABS housing adio frequency wireless remote. Temperature display. Humidity display for Vintage model. Alarm display. Time display. Defrost display. Fan speed display (EC motor only). Mode display (Hot or Cold). Humidification display for Vintage model. Condensation temperature display. LCD display with backlit. Keyboard for control and intervention. L03 AAA battery power. Installation inside or outside the cellar
4 Equipments and accessories Condensing Unit EVPL Evaporator Galvanized sheet body with Plug & Lock wall support + anti-vibration blocks al 7035 epoxy painted body for outdoor installation Air condenser on unit EVPL unit Water condenser on WEVPL unit Additional circulating fan on W units. Liquid line with dehumidifier + sigh glass HBP Pressure safety switch HP/LP KPC Condensing pressure control by speed variation of the fan with EC motor for air group unit. VEP Pressostatic water valve on W C Compressor heater with air group unit efrigerant connections with Flare valve in front with pressure plugs. Seal electrical cabine Preloading with refrigerant Accessories BNS Low noise kit Air cooling water cooling W WIELESS Controller SF appellation Genesis Cooling only CW (Cold water recycling) humidity stabilization Stainless steel thermostatic expansion valve Aluminium glossed al7024 body for models ecyclable ABS al 7024 body for models ecyclable ABS white body for models PDO Pump down solenoid valve on 170 and 230 models Flare refrigeration connections Preloaded with nitrogen Accessories: KPM wall installation kit (only for EVPL 30 to 122 models) appellation Vintage Genesis equipments more KCH heating resistor included KHG% Humidifier included Accessories: KPM wall installation kit (only for EVPL 30 to 122 models ) KLP water pressure limiter for KHG% humidifier
5 Split EVPL technical data Split systems with air or water condensing unit Split systems SPC - EVPL Ceiling evaporator T cellar= +12 C - Tout= 32 C +32 C ext SPC Cooling Capacity W Heating Capacity W 850* 850* 850* 1000* 1600* 2000* Condensing Unit SPC Voltage 50Hz 230 V/1+T 230 V/1+T 230 V/1+T 230 V/1+T 230 V/1+T 230 V/1+T Airflow m3/h Current A max 2,6 3,3 4,5 6,5 7,8 10,4 without BNS db Sound pressure level at 5m with BNS db W db Gas connections Suction (Flare) Ø 3/8" 3/8" 3/8" 1/2" 5/8" 5/8" Liquid (Flare) Ø 1/4" 1/4" 1/4" 1/4" 3/8" 3/8" Water connections for W Ø 2 x 1/2" M 2 x 1/2" M 2 x 1/2" M 2 x 1/2" M 2 x 1/2" M 2 x 1/2" M Net Weight kg Body color AL 7035 AL 7035 AL 7035 AL 7035 AL 7035 AL efrigerant 134A 134A 404A 404A 404A 404A Evaporator SPC Fan Nb x Ø mm 1 x x x x x x 200 Airflow m3/h Max current Genesis A max Classic / Vintage A max. 4,7 4,7 4,7 5,4 8 9,7 Gas connections Aspiration (Flare) Ø 3/8" 3/8" 3/8" 1/2" 5/8" 5/8" Liquide (Flare) Ø 1/4" 1/4" 1/4" 1/4" 3/8" 3/8" Net Weight kg 11, ,5 13, Body color Anthracite Anthracite Anthracite Anthracite White White * on CLASSIC and VINTAGE appellations Choose A SPLIT SYSTEM FO YOU CELLA Selection SPC 30 SPC 48 SPC 82 SPC 122 SPC 170 SPC 230 Volume Uninsulated Semi-buried Insulated* * Insulation of ceiling and walls with 60mm of PU Warning: the selections presented on this chart are indicative only and can not replace a heat balance that takes into account all the parameters related to your cellar. eference T out : 32 C T Cellar : 12 C
6 Split EVPL sizes Split GENESIS et VINTAGE - Wireless controller (SF) Condensing unit Split GENESIS and VINTAGE SPC 30* - 48* - 82** 122** SPC *- 510** BNS = *-380** BNS = Ceiling evaporators Split GENESIS and VINTAGE SPC SPC Ø Ø 20 SPC 82* - 122* - 170** - 230*** * ** *** Ø 1" G
7 Select A storage system for your wine cellar Visioack Developed specifically to facilitate research Bottles, Visioack is especially suitable for presentation in custom glass wine cabinets where rapid visualization of labels is very important. Wire design allows different models in the range to fit all styles of wineries whether rustic or contemporary. VisioPlan VisioPlus Chain My Wine VisioBois VisioCloud More informations on Website
8 Friax wine cellar air conditioners CLIMATISEUS DE CAVE À VINS SPC-EV SPLIT SYSTEMS Faire de votre cave un paradis sous terre CLIMATISEUS DE CAVE À VINS SPC-EVA SPLIT SYSTEMS Faire de votre cave un paradis sous terre Pour la CAVE Pour la CAVE CLIMATISEUS DE CAVE à VINS MPC MONOBLOC Faire de votre cave un paradis sous terre PourlaCAVE Pour la CAVE Pour la CAVE MPC-Genesis MPC-Vintage Wall mounted and ducted Splits Splits for custom made cabinet Monoblocs and ducted monoblocs ohs - WEEE Our products comply with European Direc ves 2002/95/EC and 2002/96/EC rela ng to electrical and electronic equipment DESP (Pressure Equipment Direc ve) Compressorised products comply with European Direc ve 97/23/EC concerning pressure equipment CE Our products comply with European direc ves GOST Our products comply with IEC YOU DISTIBUTO INDUSTIE FIAX Industrie 231/233 avenue de la Prairie Voglans - France Tel : +33 (0) Fax : +33 (0) info@friax.fr GB-DC-SPCEVPL-0216
MPC Genesis - Vintage
R Pour Pour la la CAVE CAVE Vos vins seront bien gardés Installation Manual "FRIAX industrie" in a constant endeavour to improve its products reserves the right to change any infmation contained in this
More informationUSER GUIDE HYGROMASTER
USER GUIDE HYGROMASTER D E F Y I N G C O N V E N T I O N Contents 1. AUTOMATIC CONTROL OF HYGROMETRY 2. INSTALLATION OF HYGROMASTER 3. STARTUP 4. USE AND MAINTENANCE: 5. MAINTENANCE 6. PRESERVATION OF
More informationcondenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications
Outdoor condensing unit for direct expansion applications Variable speed propeller fan Cooling ENVIRONMENTALLY HFC R40A PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling capacity: 5. to 8.6 kw Use The CL
More informationCONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY
CONDENSING UNITS. AIR COOLED CONDENSER. CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY SERIES: DXCZ MODELS: 171, 201, 221, 251, 271, 351 371, 401, 451, 501, 701 and 721 COOLING CAPACITIES OF: 4,7
More informationDYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers
High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers Self-adjusting electronic control Cooling capacity: 35 to 700 kw 410A Cooling Operation DYNACIAT - DYNACIAT POWER
More informationCondensate water pumps
Condensate water pumps Welcome! If reliability is your main concern, then you finally have the right document in your hand. Among our big range of condensate pumps you will certainly find the one matching
More informationZeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017
Zeta Rev LN HP 10.2 Configured unit accessories 1PS - One user-side pump with tank LN - Low noise RG - Condensation control with fan speed regulator CSP - Set point compensation depending on external air
More informationHT V2 HT Split
Scroll compressor Refrigerant R07C Aqu@Scop HT V Aqu@Scop HT Split High Temperature Air-to-Water Heat Pumps Models -, -7 and 8-9.0 to 7.9kW Aqu@Scop HT V / Aqu@Scop HT Split Installation examples - Single
More informationCATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42
SELF CONTAINED HORIZONTAL UNITS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER ) HEAT PUMP. WCHBZ COOLING ONLY. WCHZ SERIES: WCHBZ - Heat Pump MODELS: 201, 251, 271, 351, 401, 501 COOLING
More informationWATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ
WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ SERIES: EWCBZ - Heat pump MODELS: 70, 80, 00, 0, 60, 00, 40, 00, 50 COOLING CAPACITIES from 5,9 kw to 78,5
More informationSPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module
SPECIFICATION GUIDE FLEXAIR Air-cooled packaged Rooftop unit Cooling only or Heat Pump Nominal cooling capacity: 85 to 234 kw Nominal heating capacity: 83 to 226 kw Possibility to add auxiliary heaters:
More informationSELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)
SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER) SERIES: WCHZ MODELS: 201, 251, 271, 351, 401, 501, 701, 721, 751 COOLING CAPACITIES OF: 6,4
More informationSMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB
T_SMT_0609_GB 4,9 49,5 kw Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans INDEX SERIES IDENTIFICATION... 3 MODEL IDENTIFICATION... 3 CE CONFORMITY... 3 WORKING
More information4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB
4,5 22,5 kw Air-conditioned server-racks for direct installation into the room technicalcatalogue T_CLSEVO_0113_GB INDEX HIGHLIGHTS... 3 PLANT TYPE... 3 GENERAL CHARACTERISTICS... 5 SERIES IDENTIFICATION...
More informationHigh Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.
HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Cool Only 9K - 1K - 18K - 4K R-410A IAQ $ Auto Auto Fan Speed Timer s Easy Flexible Installation Smart LCD Wireless Control Auto Mode Auto Restart Easy
More informationTroubleshooting(TC32G)
Troubleshooting(TC32G) tools: Tool description (Note: Most of the repairing is same as VT60 s, so we use VT60 s picture) (1) the wine cellar does not get cold at all. 1 Check to ensure the power plug is
More informationCENTRAL SPLIT UNIT UNIC
CENTRAL SPLIT UNIT UNIC sal is equipped to produce a wide range of COOLER Air conditioning and Refrigeration units, conforming to the international standards and works continually to improve its products
More informationHYDROCIAT LW R407C. Water cooled chillers USE RANGE
Screw compressors CIAT dry direct expansion shell and tubes evaporator HPS equipment (High Power System) cooling or heating Heat recovery ENVIRONMENTALLY HFC R407C PROTECTION DE FRIENDLY L'ENVIRONNEMENT
More informationAir-to-water scroll chillers
Air-to-water scroll chillers Model CGA 040 to 115 Cooling capacity: 14-40 kw CG-PRC031B-GB Table of Contents Technical specifications...4 Standard configuration... 4 Hydraulic version... 4 Casing... 4
More informationSplit Floor-Mounted Cooling System Operation Care Installation Manual
Split Floor-Mounted Cooling System Operation Care Installation Manual CT14TSA CT13TSA CT12TSA CT34TSA CT1TSA CT14TSA-LA CT13TSA-LA CT12TSA-LA CT34TSA-LA CT1TSA-LA www.apexwinecellars.com Apex 17631 S Susana
More informationISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS
ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS BULLETIN 20-131.001 Page 1 Copyright 2017 Unico Inc. TABLE OF CONTENTS APPLICATIONS... 3 CABINET CONSTRUCTION... 3 FEATURES AND CONTROLS... 3 DIMENSIONAL
More informationPlatelet bags constant shaking for long periods of time.
Horizontal shakers for platelet bags APL-54 and APL-108 HORIZONTAL MOVEMENT AT A FIXED SPEED OF 66 R.P.M., LATERAL SHUFFLE OF 40 MM. APL-54 : CAPACITY FOR 54 PLATELET BAGS. APL-108 : CAPACITY FOR 108 PLATELET
More informationwe care about Better Air
3 Technologies & Useful Features INVERTER G2KCV Toshiba IAQ Pre-filter Filters Toshiba Airconditioning, we care about Better Air Our products comply with RoHS Regulations, ensuring no restricted substances
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 201 C K RAE 482 C K AIR R-407C Series RAE... C K from 19 to 83 kw - 1 and 2 circuits The air cooled chillers of RAE... C K series, with centrifugal fans, are designed for indoor installation and are
More informationFHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions
Dehumidifiers for radiant cooling systems with heat recovery 50 The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area
More informationHigh Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)
High Ambient / High Efficiency Series R - 410a 50Hz Ducted Split Air Conditioners (5.0 kw - 17.5 kw) ISO 9001 : 2008 ISO 14001 : 2004 ISO 18001 : 2007 R - 410a 50Hz Introduction: Established in the year
More informationR 407 C. > in industrial application. Always very much appreciated for special installations these units shown their powers :
SINGLEPACKAGE CONSOLE UNITS, MONOSPLIT, AIR CONDENSING UNITS APPLICATIONS COMMERCIAL SECTOR CONSOLE UNITS AIR CONDENSING UNITS Always very much appreciated for special installations these units shown their
More informationInverter Wall Mounted Series
PCXRY14 Inverter Wall Mounted Series R410A Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. 2014-09 Printed In Malaysia
More informationSP40DUPRO. Installation and user manual (pleasee keep this document carefully) INDICATIONS STATED ON THE NAMEPLATE OF THE UNIT :
Installation and user manual (pleasee keep this document carefully) SP40DUPRO INDICATIONS STATED ON THE NAMEPLATE OF THE UNIT : o Model :.. o Serial N :.. o Purchase date :... Page 2 GB User manual Table
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available May 2006 10 12 167 - GB - 00 MARKING
More informationRefrigerator KE T
Refrigerator KE 680-1-3T Service Manual: H8-74-07 Responsible: U. Laarmann KÜPPERSBUSCH HAUSGERÄTE AG E-mail: uwe.laarmann@kueppersbusch.de Tel.: (0209) 401-732 Customer Service Fax: (0209) 401-743 Postfach
More informationFRAL SRL via dell industria e dell artigianato, 22/C Carmignano di Brenta - PADOVA - ITALY
FRAL SRL via dell industria e dell artigianato, 22/C - 35010 Carmignano di Brenta - PADOVA - ITALY TELPHONE: +39 049 9455839 FAX: +39 049 5991129 E-MAIL: info@fral.it WEB: www.fral.it DEHUMIDIFIERS FD
More informationSERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-A Models MUZ-SF25VE - E1 MUZ-SF42VE
More informationRead and save these instructions
Split Ceiling-Mounted Cooling System Operation Care Installation Manual WM-2500SSD WM-2500SSD-LA WM-4500SSD WM-4500SSD-LA WM-6500SSD WM-6500SSD-LA WM-8500SSD WM-8500SSD-LA WM-12000SSD WM-12000SSD-LA www.vinotemp.com
More informationV ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.
HFC4 1 0 A 0-40V ~, 0Hz 1Ph High Wall Split Systems Heat Pump 9K - 1K - 18K - 4K - 8K R-410A Compressor Super Quiet AMS Anti-dust Filters Auto Fan Speed Timer Functions Defrost Protection Smart LCD Wireless
More informationSplit inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45
Plug & Heat heat pump Quick and easy to install For new homes or boiler backup operation 50 HFC R410A CERTIFIED BY CERTITA Heating capacity: 5.5 to 22 kw option CERTIFIED BY CERTITA 30/35-40/45 USE The
More informationTECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL AW22AL AW28AL AW38AL
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW22AL 387030005 AW28AL 387030006 AW38AL 387030007 AW42AL 387030094 0.8180.467.0
More information2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating
2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER AIR-TO-WATER HEAT PUMP cooling - heating MINI CHILLER Highly efficient heat pump for summer and winter air conditioning. Ideal for residential and commercial
More informationEASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB
R407C EASY_R Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans 5,2 41,5 kw T_ESY_R_0508_GB EASY_R R407C INDEX WORKING LIMITS... 3 SERIES IDENTIFICATION... 4 MODEL
More informationSERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E
Revision E: The descriptions of the expansion valve coil have been corrected. (11-4.) Please void OBH629 REVISED EDITION-D. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH629 REVISED EDITION-E Models
More informationKälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10
Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW Compressors Scroll Serie: Series: Emissione: Issue: SCAEY Catalogo: Leaflet: Sostituisce: Supersedes: DE 88 04/11 12/10 Index
More informationAll side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.
All outdoor units are designed to perform satisfactorily at 52 C, with the option of either top discharge condensing units, with Copeland reciprocating scroll compressors. All top discharge condensing
More informationROOFTOP PACKAGED AIR CONDITIONERS
ROOFTOP PACKAGED AIR CONDITIONERS Rooftop Packaged Air Conditioners Hitachi has long been a world leader in the design and manufacture of quality air conditioning systems. With models ranging from room
More information6. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air cooled cooling only type)
6. INVERTER MULTI-SPLIT SYSTEM ROOM AIR-CONDITIONER (Air cooled cooling only type) (OUTDOOR UNIT) (INDOOR UNIT) SKM222CENG-L SKM252CENG-L SKM402CENG-L 221 CONTENTS 6.1 GENERAL INFORMATION... 223 6.1.1
More informationTECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental
TECAM S.A. Tecnología Ambiental R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz harmony 5PZA Direct Expansion Registration No.: SC 4696-1 Registration No.: CO-SC 4696-1 Air Conditioning Equipment Manufacturer
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw CHGV 22 CHGV 2 CHGV 32 CHGV 40 PHRV heat pump model also available September 2007 10 12 11 - GB - 02
More informationCHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw
TECHNICAL INSTRUCTIONS CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw CHGV 50 CHGV 64 CHGV 72 CHGV 80 PHRV heat pump model also available November 2007 10 12 167 - GB -
More information1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...
FIXED FREQUENCY U-MATCH AIR CONDITIONERS TECHNICAL SALES GUIDE Capcity Range: 18000~ 60000 Bth h T3R2250Hz CONTENTS 1. MODELS LIST... 3 2. NOMENCLATURE... 4 3. FEATURES... 5 4. PRODUCT DATA... 9 5. FAN
More information30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw
Air-Cooled Liquid Chillers Nominal cooling capacity 21-94 kw Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. The
More informationRSES Technical Institute Training Manual 2 72 hours, 72 NATE CEHs, 7.2 CEUs
Lesson 1 - Trade Tools Explain the importance of using proper tools and test instruments. List the various types of wrenches and describe their use. Describe the proper procedures for bending, flaring,
More information> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center
Uniflair LE TDER-TUER Energy-saving units with backward-curved fans 20-100kW > Perimeter cooling for medium/large data center > Refrigerant R-410A Available Versions: > Downflow (TDER) > Upflow (TUER)
More informationSUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:
M4MCW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity
More informationWORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)
WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD (1132718-M) WALL MOUNTED SPLIT UNIT LOMO N Series WALL MOUNTED SPLIT UNIT R410A Eco-friendly Refrigerant Quiet Fast Cooling
More informationTECHNICAL DATA & SERVICE MANUAL MTF94C5TAA
TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA 0.8180.472.0 07/2005 Page 1. SPECIFICATIONS 3 1-1 Unit Specifications 3 1-2 Major Component Specifications 4 2. DIMENSIONAL DATA 6 2-1 Unit Dimensions 6 3. ELECTRICAL
More informationCIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet
Attractive design, Compact and quiet Many customisable configurations possible For indoor installation New reliable technologies Version with Plug and Cool hydraulic module Cooling capacity: 23 to 140
More informationAPPLICATION GUIDE FLATAIR FMC - H FIC - H FSC - H. Horizontal packaged air conditioners kw FLATAIR AGU-MSL E. lennoxemeia.
APPLICATION GUIDE FLATAIR FMC - H FIC - H FSC - H Horizontal packaged air conditioners 10 28 kw FLATAIR AGU-MSL60-1505-E lennoxemeia.com INDEX FLATAIR TM APPLICATION GUIDE Ref : FLATAIR AGU-MSL60-1505-E
More informationRead and save these instructions
Split Water-Cooled Through-Ceiling Cooling System Operation Care Installation Manual WM-2500SSOWC WM-4500SSOWC www.vinotemp.com Read and save these instructions Vinotemp International Corp 17631 S Susana
More informationRead and save these instructions
Split Water-Cooled Central-Ducted Cooling System Operation Care Installation Manual CT14TSHWC CT13TSHWC CT12TSHWC CT34TSHWC CT1TSHWC www.apexwinecellars.com 17631 S Susana Road Rancho Dominguez, CA 90221
More informationSUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:
M4MHW1509A-SUB-1B TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA 2017 Ingersoll Rand All Rights Reserved MODEL - Heat Pump Only RATED Volts/PH
More informationOutdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments
Outdoor Enclosures Outdoor Enclosures Protected like a bunker for all harsh environments sales@mcldatasolutions.co.uk +44(0)1702 443810 mcldatasolutions.co.uk Outdoor enclosures and climate control components
More informationApplication guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort
Application guide FLATAIR - FLCK/FLHK Providing indoor climate comfort MSL60E-0701 12-2006 Congratulations you have made a wise choice and we feel sure that it will meet your expectation INDEX CONTENTS
More informationMiraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.
MISR REFRIGERATION & AIR CONDITIONING MFG. CO. COOL EER HEAT COP 0V ~ 50Hz 1Ph Inverter High Wall Split Systems For Energy Saving Heat Pump 1K - 18K - 4K DC Inverter R-410A Inverter Technology R-410A HFC
More informationSUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:
M4MCW1509A-SUB-1C TAG: 15 SERIES SUBMITTAL Specifications Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA MODEL - Cooling Only RATED Volts/PH Frequency (Hz) Rated Cooling Capacity
More informationAir treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings
0932EN October 2017 CHARACTERISTIC DATA Air flow rate [m 3 /h] 200 Pressure available (factory configuration) [Pa] 15 Moisture removed (26 C - 65% R.H. - inlet water 15 C) [l/24h] 24,7 Max. absorbed electric
More informationMULTI-SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP. YN-M Series. Inverter++ Models. Two, Three, Four, and Five Zones (Dual, Triple, Quad, and Quint Multi)
MULTI-SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP YN-M Series Inverter++ Models Two, Three, Four, and Five Zones (Dual, Triple, Quad, and Quint Multi) Owner s Manual IMPORTANT NOTICE: Read through and fully
More informationREFRIGERATOR M E D I C A L.
M E D I C A L REFRIGERATOR NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation. LRM-100 SERIES Labocon Medical Refrigerator LRM-100 Series
More informationLaboratory Deep Freeze Storage Cabinet TC 230 Air circulated
External Dimensions: B = 600 mm D = 650 mm (at -30 C/-40 C: 760 mm) H = 1640 mm (at -30 C/-40 C: 1720mm) Internal Dimensions: B = 500 mm D = 500 mm H = 890 mm Capacity: 300 l Temperaturerange: Optional:
More informationEXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction
Reducted footprint Dual-wall construction Built-in variable frequency drive PLC control Variable speed condenser fan Cooling capacity: 5 to 50 kw Air flow: 1 000 to 12 000 m 3 /h ErP READY Use Precision
More informationTOSHIBA AIR CONDITIONING
Digital Inverter Standard Specification R32 Introduction The following specification describes the Toshiba Digital Inverter Heat Pump air conditioning system(s) to be installed at the below site: (ADD
More informationCMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL
CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION ECO-FRIENDLY REFRIGERANT GAS INSTALLATION AND OPERATION MANUAL Dear Customer, Thank you for having purchased a FERROLI product. It is the result of many years
More informationGHE Dehumidifiers for radiant cooling systems with heat recovery
Dehumidifiers for radiant cooling systems with heat recovery The dehumidifiers with heat recovery of high efficiency series were designed to provide dehumidification and fresh air in a residential area
More informationTECNAIR LV C series Close control air conditioners
TECNAIR LV C series Close control air conditioners with direct expansion coil with chilled water coil C series Close control air conditioners Main features Designed for electronic and comfort applications
More informationAIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS
RAE 1402 C O K AIR R-407C Series RAE... C K Cooling capacity from 81 to 250 kw - 2 circuits The air cooled chillers of RAE C K series, with centrifugal fans, are designed for indoor installation and are
More informationTECNAIR LV C series Close control air conditioners
TECNAIR LV C series Close control air conditioners with direct expansion coil with chilled water coil C series Close control air conditioners Main features Designed for electronic and comfort applications
More informationRead and save these instructions
Split Through-Ceiling Cooling System Operation Care Installation Manual WM-2500SSO WM-2500SSO-LA WM-4500SSO WM-4500SSO-LA www.vinotemp.com Read and save these instructions Vinotemp International Corp 17631
More informationLaboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)
External Dimensions: B = 1500 mm D = 820 mm H = 2100 mm Inside Dimension: Room 1 B = 600 mm D = 670 mm H = 1330 mm Room 2 B = 600 mm D = 670 mm H = 1330 mm Capacity: 1500 l Temperature range: Room 1 2
More informationTABLE OF CONTENTS. NOTE: Read the entire instruction manual before starting the installation. TROUBLESHOOTING... 13
R 410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H) System, DFC4(A/H)3 Outdoor, DFF4(A/H)H Indoor NOTE: Read the entire instruction manual before starting the installation.
More informationMedical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345
External Dimensions: B = 530 mm D = 640 mm H = 1600 mm Inside Dimension: Useful space on top Useful space at the bottom B = 450 mm B = 450 mm D = 535 mm D = 535 mm H = 530 mm H = 530 mm Capacity: 280 l
More informationAURA SERIES 9000 BTU BTU BTU BTU LETO SERIES 9000 BTU BTU BTU BTU
AURA SERIES 9000 BTU 12000 BTU 18000 BTU 24000 BTU LETO SERIES 9000 BTU 12000 BTU 18000 BTU 24000 BTU Energy Star Efficiency The Aura Series by Senville enjoys certifications by Energy Star, meaning that
More informationINSTRUCTIONS! DO NOT DISCARD!
INSTUCTIONS! DO NOT DISCAD! CAUTION! Do NOT install where injury might occur due to Moving parts, Sharp corners, Hot surfaces or electrical components dcn0812 Page 1 of 11 INSTALLATION INSTUCTIONS CAUTION
More informationAir Conditioner SVC MANUAL(Exploded View)
Internal Use Only http://biz.lgservice.com Air Conditioner SVC MANUAL(Exploded View) Type : Ceiling Concealed Duct MODEL : AMNW24GBGA0 [LMHN240HV] AMNW36GBGA0 [LMHN360HV] CAUTION Before Servicing the unit,
More informationDOUBLE DOOR FREEZER.
DOUBLE DOOR FREEZER www.labocon.com NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation. UPRIGHT FREEZER DOUBLE DOOR LUFD-25-100 SERIES Labocon
More informationAIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW
AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW Row Cooling Precision Air Conditioner Cooling Capacity: 26.2kW~68.6kW CHILLROW is installed closely with the server cabinets and refrigerating independently. The
More informationWall Mounted Split Systems
MWM - 2005 Wall Mounted Split Systems Models: MWM 007F/FR MWM 010F/FR MWM 015F/FR MWM 020F/FR MWM 025F/FR MWM 030F/FR Contents Features... 1 Nomenclature... 2 Specifications... 3 Performance Table... 11
More informationInverter Ducted Air Conditioners
Inverter Ducted Air Conditioners About Carrier Inverter Ducted Systems Carrier s Inverter Ducted systems allows you to air condition your home without having to install the indoor units on your wall, making
More informationSingle Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return
Single Zone System One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return Multi Zone System Used in small to medium sized buildings
More informationTECHNICAL CATALOGUE SELF-CONTAINED VERTICAL UNITS AIR / AIR DC INVERTER
TECHNICAL CATALOGUE SELF-CONTAINED VERTICAL UNITS AIR / AIR DC INVERTER Models : 601, 741, 901 ACVIA - Cooling only (Compact) CCVIA / ECVIA - Cooling only (Split) ACVIBA - Heat Pump (Compact) CCVIBA /
More informationMidea Ducted and Cassette Split Systems. Year round comfort, all around the house.
Midea Ducted and Cassette Split Systems Year round comfort, all around the house. Year round comfort, all around the house A Midea ducted inverter system puts total climate control right at your fingertips.
More informationRead and save these instructions
Split Water-Cooled Central-Ducted Cooling System Operation Care Installation Manual WM-2500SSHWC WM-4500SSHWC WM-6500SSHWC WM-8500SSHWC WM-12000SSHWC www.vinotemp.com Read and save these instructions Vinotemp
More informationArmoire à vin. Beverage Preservation Technology USER MANUAL 40BVC AL-V40BVC
Armoire à vin. Beverage Preservation Technology USER MANUAL 40BVC AL-V40BVC WARNING The information in this document is subject to modification without any prior notice. VINTEC offers no guarantee for
More informationInstallation Manual BCS 1000/1500
Installation Manual BCS 1000/1500 Supplies Needed for Installation 1. Double insulated refrigerant line set. 2. 1/4 copper water supply 3. 1/4 condensate vinyl drain tube/tube clamps 4. Provide 120V 15A
More informationECB Specification: Electric control box: W 300 * H 400 * D 150 (mm)
ECB-5070 General descriptions: This product has the function of current display and motor integrated, which can effectively avoid the various danger caused by the instability of current and voltage, to
More informationTHE CARRIER COMFORT LINE
SPLIT SYSTEM SPLIT SYSTEM AIR/AIR TECH 2000 38 TUA/38 CKX 38 YCX - FB4 ASX THE CARRIER COMFORT LINE OUTDOOR UNIT THE ROAD TO All the materials used are designed and protected to resist the toughest climates:
More informationHCompact2 HA. Compact air-air stand-alone units. Compact horizontal Reduced dimensions Centrifugal fans RANGE DESCRIPTION OPERATING LIMITS SERIES
Cooling capacity: Heating capacity: 7,0 to 36,8 kw 8,7 to 40,1 kw Compact horizontal educed dimensions Centrifugal s Ducted aspiration and discharge DESCPTON The heat pumps and cooling unit are compacts
More informationBEFORE USING YOUR WINE CELLAR SAFEGUARDING THE ENVIRONMENT
BEFORE USING YOUR WINE CELLAR The appliance you have purchased is a wine cellar (or wine-cooler), a professional product designed exclusively for storing wine. To get the most out of your new appliance,
More informationART الرفاهية تكنولوچيا بلمسة فنية
ART 010-012 الرفاهية تكنولوچيا بلمسة فنية Air Conditioner Outdoor Unit Features: Fast installation and easy maintenance. Modern cabinet design to suit the building decorations. Low-noise, high efficiency
More informationEVAPORATIVE COOLER PUMPS
EVAPORATIVE COOLER PUMPS ebmpapst Evaporative Cooler Pump EBMALPHA $144.65 @ 1. metre Head @ 2. metre Head Power Supply 32 litres/min 25 litres/min 24V/1/5Hz Nominal Watts 5 watts Outlet Connection 2mm
More informationNote: before using the system read this manual carefully, store it and, in case, transfer it to a new user. prima
page 1 Note: before using the system read this manual carefully, store it and, in case, transfer it to a new user. prima No-idle auxiliary battery operated air con PICCOLO SPLITTER Model PS3000 MY2012
More informationWINE PC10 Octobre 2006 WINE PC10. Instructions for installation and use
WINE PC10 Instructions for installation and use CONTENTS Introduction :From the vine to the wine...page 3 1. General information...page 4 1.1 Technical properties...page 4 1.2 Required space...page 5 1.3
More informationINVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER
INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER Owner s Manual Model: 3554190/3554191/3554192/3554193 3554194/3554195/3554196/3554197 IMPORTANT NOTE: Read this manual carefully
More information