Operation Manual. PalmCare plus Handheld Pulse Oximeter (Ver 1.0)

Size: px
Start display at page:

Download "Operation Manual. PalmCare plus Handheld Pulse Oximeter (Ver 1.0)"

Transcription

1 Operation Manual PalmCare plus Handheld Pulse Oximeter (Ver 1.0)

2 CONTENTS Before using the product Screen configuration Contacts Palmcare plus Basic Operation 23 Product Guarantee Operation Symbols in the Manual MENU SETTING Precautions for use ALARM SETTING Precations for Electrical Safety 9 Initial Display Setting Mode 29 Characteristics and Principles of PalmCare plus 10 Screen Setting Composition of PalmCare plus 11 Sound Setting How to set PalmCare plus - 12 Delete the TREND Precations for Settings Select Language Information of Palmcare Checkpoints Before Use plus Maintenance and Cleaning Trend Funtion PalmCare A f t e r U s e plus Precations for using Measuring of Spo2 42 Components of PalmCare plus- 15 Alarm Function Front & Operation Panel Power & Battery specification R i g h t S i d e AC POWER T o p S i d e Battery Specifications Bottom Side Before Requesting After Service 49 Back Si de Product Specification Description of Product Symbols- 18 2

3 Before Using the Product Thank you for purchasing PalmCare plus(handheld Pulse Oximeter). For safe and efficient operation, please read the manual to learn about the functions of the product before use. Please keep this manual nearby to assist you with operating the functions of the product. The product should be used under the supervision of a medicalrelated certified professional. The product is used for examining patient s abnormal condition. For the safety of the patient, only the components or the accessories recommended by our company should be used. If you connect any accessories to the product that is not specified in the manual, please be sure to notify our company or an agency authorized to distribute our products. Contacts For various services and product information, please feel free to contact our salesperson at the following number. For any questions about use or setup of the product, please contact the following number. Technical Support BIONICS Co,.Ltd Tel: * For reporting defects or abnormalities, please note the model name, product serial number, purchasing date, and abnormal points before contacting us. 3

4 Product Guarantee The product you have purchased comes with a 1-year warranty from the purchasing date covering inferior materials and the manufacturing process. For the disposable products, a warranty is given for 6 months from the purchasing date or 6 months from its first use covering inferior materials and the manufacturing process. This warranty cannot be applied to consumption supplies such as the battery, external cables, cradle and disposable accessories. We are not responsible for any physical, financial and mental loss or damage and direct or indirect expenses caused by, or resultant from, accidental or special circumstances during the use of the product. The warranty is limited to the repair or exchange of the product by the authority of the company or the agency, for problems in materials or the manufacturing process which occurred during use under normal circumstances. The company has no legal responsibility for the confirmation of services, declarations or whole warranty beyond the warranty specified above, which were supplied or will be supplied by the agency or the staff of the company at their own discretion. The user cannot request the company of services, declarations or whole warranty which were supplied or will be supplied by the agency or the staff of the company at their own discretion based on the statements above. The contents of this warranty represent all other warranties indicated or implied, and also represent all kinds of service- related responsibilities of the product sellers for the product they sell. The product was manufactured under strict quality controls and the inspection process of the company. The indemnification standard for product repair and exchange is according to the Economic Planning Board notification Regulation for the indemnification of consumer damage 4

5 Symbols in the Manual Some symbols are used in this manual to help users or patients use this product safely and appropriately and to prevent any risk to patients or damage to materials. Please read and understand all warnings and precautions. Each symbols mean : WARNING The Warning symbol indicates that a dangerous situation may occur resulting in fatal injury or death of the patient, or may incur material and financial damage when the warning is ignored. CAUTION The Caution symbol indicates that a situation may occur resulting in injury or damage to the patient, though not life-threatening, when the caution is ignored. NOTE The Note symbol is used to inform you of important, but not dangerous, information regarding installation, use, and maintenance of the product. Warning Use of this product is prohibited during MRI photographing. A fire may breakout from the induced current, and the accuracy of the product and the MRI may be influenced by mutual interference. All cables should be set properly. Cables and hoses etc. should be kept away from the patient, so that there is no possibility of the patient s neck being entangled in them, and the cables and lines should be well arranged for the safety of the staff in the hospital. The computerized ECG analysis should be judged by qualified medical professionals, and it should not be the sole basis in determining necessity of treatment for the patient. 5

6 Precautions for Use Do not operate or store the equipment under the following environments. 6

7 Standard operational conditions are as follows. - Temperature : 10 ~ 40 (50 ~ 113 ) - Altitude : 70 ~ 106Kpa - Humidity : 30 ~ 85% Standard storage and transportation conditions are as follows. - Temperature : -10 ~ 50 (14 ~ 122 ) - Altitude : 70 ~ 106Kpa - Humidity : 20 ~ 95% 7

8 CAUTION The product may not work well when it is kept or operated beyond the temperature and humidity specified. If you want to turn off the PalmCare plus while you re operating, please use the power switch where is the front of the product. When you keep or operate the product in large temperature difference, product malfunctioning can be happened because of humidity of battery pack. Please operate product after keep it room temperature for three hours. CAUTION Leakage, heating, ignition or rupture of the battery may cause fire or injury. Do not use batteries beyond those specified in this manual. Do not short-circuit the battery and do not heat, disassemble, or dispose of it in a fire. Do not mix using the used battery with new batteries, different kind of batteries, other company batteries When the product is not used for a long time, separate the battery from the product. To ensure the lifecycle and safety of battery, please discharge the battery and then charge perfectly again every six months. Also time-worn battery exceed 24 months should be replaced. When the product has been moved, make sure to turn it off and arrange the accessories in order. Injured cords or cables may cause fire or electric shock. 8

9 Precautions for Electric Safety Prior to operation of the equipment, make sure to check following itmes. 1 Whether power supply is appropriate. (AC100V~AC220V) 2 Whether connections (power line or selected equipment) are properly made to the equipment. 3 Whether Probes are connected before the systems is turned on. CAUTION The equipment should be placed far from generator, X-ray equipment, broadcasting equipment, or transmitting wires, so as to prevent the electrical noises form being generated during the operation, when these devices are near the equipment, it can produce inaccurate measurements, For Palmcare plus, both independent circuit and stable grounding are essentially required. In the event that same power source is shared with other electronic equipment, it can also produce inaccurate output NOTE Palmcare plus is classified as follows; It is a Class II, type-bf against electric shock. Equipments are not suitable for use in presence of a flammable anaesthetic mixture and a solvent. 9

10 Description of Palmcare plus Characteristics and Principles of PalmCare plus PalmCare plus is pulse oximeter for measuring oxygen saturation of arterial blood and plus rate of patient. Data and detected wave are displayed on the front LCD. There are two types of probe to the Plamcare plus. One is reusable probe and the other is disposable probe to apply neonate or pediatric patient as well as single use to adult. There are two principles that pulse oximeter is based on. Oxyhemoglobin and Deoxyhemoglobin differ in spectral absorption, the relative absorption of red and infrared light by bold reflects hemoglobin oxygen saturation. And the changed volume of arterial blood in tissue could be measured during the pulsatile cycle. A pulse oximeter measures the oxygen saturation of arterial hemoglobin by passing red and infrared light emitting diodes(led) in the oximeter sensor serve as light source (ultraviolet rays 660nm and infrared light 960nm); a photodiode serves as the photo detector. Pulse rate and arterial blood oxygen saturation are pleased on a LCD display in the real time. Users can determine the alarm settings and volume as needed via cont 기 key panel on the front. PalmCare plus gives the operator the ability to measure patient basic vital biometric data. 10

11 Composition of PalmCare plus(accessories) Standard Accessories SpO 2 Main 1 set Finger Probe (1EA) Adapter(1EA) DC 5V 2A Operation Manual (1EA) Optional 1 Disposable probe 2 Extension cord 2.4m(8ft) 3 Cradle 4 USB(mini B TYPE) serial cable 11

12 How to Set PalmCare plus (1) Precautions for Settings Pay attention when setting Palmcare plus for the following points - Use Palmcare plus under conditions of of circumstantial temperature and 30% 85% humidity. - Check the connection status of the power cord. - Do not connect multiple cords to the power supply. - Place the main body on a flat area. - If noise occurs, ground the equipment. - Do not use any electric cords generating connecting noise. - Take care since the product can be broken by mechanical shock. - Get rid of dust or inflammable material near the product when setting it up. (2) Checkpoints before Use Check the following points before measuring the patient s condition. - Make sure there is no mechanical risk. - Check the lead, power plug, and accessories connected on the outside. Precautions Before Use 1 Do not use product near dynamo, X-ray equipment, broadcast equipment. 2 Do not twist the cable. 3 Attach each Lead properly. 4 Keep the patient motionless with comfortable position while measuring. 12

13 (3) Maintenance and Cleaning After Use A. Keep the product cleans by cleaning it using a soft cloth at least once a month. Do not use thinner, ethylene, oxidant or lacquer since these may damage the product. B. Keep the accessories clean of dust or foreign materials. For cleaning, use a soft cloth and clinical alcohol. C. Do not soak the accessories in liquid or detergents. Keep the product and accessories out of any liquid. D. For the protection of the environment, please contact the agency you purchased the product from when you wish to discard the Palmcare plus. E. Our product can be used semipermanently. Please contact our Customer Service dept. or any distributor and then replace the parts, when wasting parts such as battery. (4) Precautions for using 1 Precautions for environment ⅰ. Keep it away from wet place or do not use it by wet hands. ⅱ. Temperature range for use 10 ~40, humidity 30%~85%. ⅲ. Avoid areas of high humidity or ventilations problems ⅳ. Keep it away from any electric heater.. ⅴ. Keep it away from direct sunlight. ⅵ. Avoid areas susceptible to large shock or vibration ⅶ. Avoid areas near chemicals or explosive gas. ⅷ. Make sure to not let any dirt or especially metallic objects from going inside the equipment. 2 Precautions for electric safety 13

14 ⅰ. To avoid electrical noise or disturbance, install the device away from generators, X-ray devices, broadcasting devices and idle wires. Inaccurate reading may show in case above mentioned devices are nearby. ⅱ. Check power supply line of device is proper. ⅲ. Check every connection parts(power line or any optional device) are connected to the device properly. ⅳ. Noise may be made if the device isn t completely grounded. 3 Precautions for using ⅰ. Do not disassemble the device. ⅱ. Do not connect power source before product is installed completely. ⅲ. Do not short-circuit the battery and do not heat, disassemble, or dispose of it in a fire. 4 Precautions for disuse For the protection of the environment, please contact the agency you purchased the product from when you wish to discard the battery. 14

15 Components of Palmcare plus (1) Front & Operation Panel a POWER BUTTON : Power On/Off b MENU BUTTON : Change the setup value c ALARM BUTTON : Alarm sound On/Off d EVT BUTTON: Store the data that specified time. e UP/DOWN BUTTON: Menu UP/DOWN button. f TREND BUTTON : Check the EVENT data g ESC BUTTON: Exit Menu screen h ENTER BUTTON : Select Menu and Alarm value.. 15

16 (2) Right Side a Wrist string attaching part (3) Top side a Finger Probe Connector (4) Bottom Side a Host Interface(USB communication connector) b DC adapter connector 16

17 (5) Back Side a Battery Cover(Battery insertion part) b Cradle Attaching Part. CAUTION In order to avoid electrical shock, do not open the cover. Disassembling of the equipment must be done only an by service personnel who is authorized by BIONICS. 17

18 Description of Equipment Symbols Symbol Description Symbol Description Type BF equipment. Type BF equipment is suitable for intentional external and internal application to the patient, excluding a direct conductive connection to the patient s heart. This symbol means attention during operation. You should pay special attention to the equipment when the equipment is operated in conjunction with other equipment. DC 5V POWER INPUT POWER SWITCH ALARM SOUND ON/OFF UP/DOWN BUTTON MENU BOTTON Event Save BOTTON Trend BOTTON ESC BOTTON ENTER BOTTON OXYGEN SATURATION HEART BEAT RATE PER MINUTE 18

19 Screen Configuration Initial screen is shown after system boot and test for about 3 seconds, if you turn the power on. PalmCare plus offers six kinds of initial screen as the following pictures for the user s convenience, initial screen displayed on pressing power button can be set up differently. Please refer the chapter 6 for how to set up each initial display mode. - Vertical mode initial screen (1)Large Wave Mode (2)Small Wave Mode (3)Pleth Bar Mode (1)Big Wave Mode 1 The domain showing various kinds of icons which describe the current state(information Alarm) of PalmCare plus 2 Measured SpO₂and pulse rate value 3 Big Wave (2)Small Wave Mode 1 The domain showing various kinds of icons which descried the current sate (information Alarm) of Palmcare plus 2 Measured SpO₂and pulse rate value 3 Small Wave (3)Pleth Bar Mode 1 The domain showing various kinds of icons which descried the current sate (information Alarm) of Palmcare plus 2 Measured SpO₂and pulse rate value 3 Pleth Bar 19

20 - Horizontal Mode initial screen (1)Large Wave Mode (2)Small Wave Mode (3)Pleth Bar Mode (1)Big Wave Mode 1The domain showing various kinds of icons which describe the current state(information Alarm) of PalmCare plus 2Measured SpO₂ and pulse rate value 3Big Wave (2)Small Wave Mode 1The domain showing various kinds of icons which describe the current state(information Alarm) of PalmCare plus. 2Measured SpO₂ and pulse rate value 3Small Wave (3)Pleth Bar Mode 1 The domain showing various kinds of icons which describe the current state(information Alarm) of PalmCare plus. 2 Measured SpO₂ and pulse rate value 3 Pleth Bar Each shape and meaning of the icons describing the current state(information alarm) of Palmcare plus is as below.. 20

21 (Table1). Description of Screen Icon ICON Measurement and operation condition How to display Alarm Off fixed Running out battery power Blink every 1seconds Screen select Icon fixed Language select Icon fixed Sound Off fixed Falling out the probe connection (Sensor Off) Searching pulse(in case the probe insert finger at first) Low volume of the blood flow(low Perfusion) High intensity of radiation in light (High Ambient) Falling finger off the probe(no Finger) Blink every 1seconds Blink every 1 seconds Blink every 1 seconds Blink every 1 seconds Blink every 1 seconds 21

22 Function of the buttons Each buttons on the PalmCare plus services more than two use according to the screen. The use meaning for each screen is as below chart. Button Display Mode Initial Screen Initial Screen Initial Screen Initial Screen TREND Screen Initial Screen TREND Screen Initial Screen Initial Screen Initial Screen Alarm Screen Commonness for all kind of the screens. Meaning and Operation Move to SETUP(Environment Set up) Screen Alarm On/Off Save the current measured value (Spo2 & HR) in Trend Log Up / Increase the value on setting up the Alarm range Page Up(previous page) Down / Decrease the value on setting up the Alarm range Page Down(Next page) Show Time-based TREND data(spo2 & HR) and move screen. ESC(Moving to initial screen) ENTER (Input or select) Change the setting value on Alarm screen. Power On/Off 22

23 Palmcare plus Basic Operation (1) OPERATION Step 1 Please press the power button in front- lower of the equipment. The power is to be impressed and Palmcare plus automatically starts the self-test. (You can see the BIONICS logo on the screen during self-test) Step 2 Screen will be displayed the value and waves of patient after attaching the finger probe. Step 3 if you want to change the setting value, please press the MENU ( ) button. Also if you want to examine the Trend Data, please press the TREDN ( ) button. NOTE Push and hold the power button for 1~2 seconds when power off. Power off automatically when no inputting data for 1 minute when battery mode. 23

24 Environment Setting of Equipment Menu Setting You can set the all menu pushing MENU button ( ) Step 1 If you press MENU button ( ) on the initial screen of Palmcare plus, the environment setting mode will be shown as below. Press MENU ( ) Button. Step 2 Press the ENTER ( ) button and enter setup screen you want, after making reverse turn item you want by using UP/DOWN ( / ) button. Step 3 In case you want to return to the initial screen, press ECS ( ) Button. 24

25 Alarm Setting The below screen will be shown if you press ENTER ( ) button, after making reverse the item 1. Alarm Setting on the environment setting screen of Palmcare plus. (Alarm setting screen) Step 1 Step 2 The change of the setting value can be controlled by the UP/DOWN ( / ), the item moving can be controlled ENTER ( ) button. The SETUP screen can be returned if you press the ECS ( ) button after completed inputting Alarm setting. If you press continuously UP/DOWN ( / ) button, the value is increased or decreased continuously after about one second and the value is increased or decreased by one for each on time pressing the UP/DOWN button. The changed alarm range will be displayed on The LCD as soon as you set up new alarm range. Please refer the below chart for the allowable adjustment range of this. Setting Default Range value HI LOW HI LOW HR LOW+1 ~ ~ HI-1 SpO₂ LOW+1 ~ 100, OFF 1 ~ HI-1 Suspend Time 1 Min 1 Min / 2 Min / 3 Min, OFF The LOW+1 in the chart means low limit value +1, the HI-1 means high limit value -1. For example, if low limit value for HR is 55, the HI value range for HR can be adjusted as some numbers between 56 to 299.On the contrary, if high limit value for HR is 150, the LOW value range for HR can be adjusted as some numbers between1 to

26 The value range for SpO2 also can be applied of the same rule of setting up HR value. The only difference is the high limit value can be OFF This OFF means the measured SpO2 value beyond the high limit range will not be checked for alarm. High Pulse Rate Alarm Limit Adjust Mode After selecting HR high (the digits in right side of the colon is reversed) on the alarm setting screen, you can change the value as you want by UP/DOWN. ( / ) button and then press ENTER button. Now, you can adjust the high pulse rate alarm limit like this Low Pulse Rate Alarm adjust Mode After selecting HR Low (the digits in right side of the colon is reversed) on the alarm setting screen, you can change the value as you want by UP/DOWN ( / ) button And then press ENTER button. Now, you can adjust the low pulse rate alarm limit like this. High SpO₂Alarm Limits Adjust Mode After selecting SPO2 High ( the digits in right side of the colon is reversed) on the alarm setting screen, you can change the value as you want by UP/DOWN ( / ) button and then press ENTER button. Now, You can adjust the high oxygen saturation alarm limit like this 26

27 Low SpO₂Alarm Limits Adjust Mode After selecting SPO2 Low ( the digits in right side of the colon is reversed) on the alarm setting screen, you can change the value as you want by UP/DOWN ( / ) button and then press ENTER button. Now, you can adjust the low oxygen saturation alarm limit like this. Information Alarm ON/OFF Information Alarm is a kind of sound alarm ringing when a probe has slipped off or when a probe connector is pulled off from the Palmcare plus. At this time, this is an item to decide wether this information alarm will activate (setting on) or will not (setting off). After selecting Info Alarm ( the on/off in right side of the colon is reversed) on the alarm setting screen, you can select on/off as you want by UP/DOWN ( / ) button and then press ENTER button. Now, you can adjust how to turn on or off the information alarm like this. 27

28 Alarm Suspend Time value setting Alarm suspend time value means not to make any alarm sound during the set time. In other words, the user can make not to activate the alarm sound for a while. The time can be adjusted as 1MIN/2MIN/3MIN/OFF If the event caused the alarm will not be terminated during the set time, the alarm sound will activate again. The alarm will not ring if you set the Suspend Time as OFF, even though the alarm occurs As this shape icon ( ) s displayed on the LCD of the initial screen during Suspend time, you can find out that the current alarm is suspended state. After selecting Suspend Time( the value in right side of the colon is reversed) on the alarm setting screen, you can adjust suspending time as you want by UP/DOWN button ( / ) and then press ESC button to return to the initial screen of the environment setting. 28

29 Initial Display Setting Mode (Display Mode) Step 1 You can enter to the initial display setting mode if you press ENTER button ( ), after making a reverse the item 2. DISPLAY MODE on the environment setting (SETUP) screen. Making a reverse the item 2.Display Mode by UP/DOWN button. Press ENTER ( ) button Step 2 You can use UP/DOWN ( / ) for the item moving, and ENTER ( ) button for your choice. 29

30 Step 3 You can return automatically to the SETUP screen if you choose the mode by ENTER button. And if you want to cancel the selection and return to the SETUP screen, you can go back to the SETUP screen with ESC( ) button. The initial display mode of PalmCare plus is Vertical Large Wave. 1 Horizontal Large Wave 2 Horizontal Small Wave 3 Horizontal Pleth Bar 4 Vertical Large Wave 5 Vertical Small Wave 6 Vertical Pleth Bar 30

31 Screen Setting (Vertical/Horizontal) Step 1 You can enter to the initial display setting mode if you press ENTER button ( ), after making a reverse the item 3. LCD VIEW on the environment setting (SETUP) screen. Making a reverse the item 3.LCD VIEW by ENTER button. Press ENTER ( ) button 단계 2 You can use UP/DOWN ( / ) button for the item moving, and ENTER ( ) button for your choice. (1)Horizontal (2)Vertical 31

32 Step 3 You can return automatically to the SETUP screen if you choose the mode by ENTER button. And if you want to cancel the selection and return to the SETUP screen, you can go back to the SETUP screen with ESC( ) button. 32

33 Sound Setting (Sound High/Low/Off) The sound ON/OFF set up is used for the Heart Beating Sound (Peak Sound), buttons sound which can be heard on pressing the buttons and turning on/off the sound. Step 1 You can enter to the High/Low/Off setting mode if you press ENTER button ( ), after making a reverse the item 4.Sound Volume on the environment setting (SETUP) screen. button. Making a reverse the item 4.Sound Volume by UP/DOWN Press ENTER( ) button Step 2 You can use UP/DOWN ( / ) button for the item moving, and ENTER ( ) button for your choice. i. 1.Sound Off : Volume Off. ii. 2.Sound Low : Low volume. iii. 3.Sound High : High volume. 33

34 Step 3 You can return automatically to the SETUP screen if you choose the mode by ENTER button. And if you want to cancel the selection and return to the SETUP screen, you can go back to the SETUP screen with ESC( ) button. The initial Sound Mode of PalmCare plus is set as on.. As this shape icon is displayed on the LCD of the initial screen, if you set the sound off, you can find out that the current sound is OFF state. 34

35 Delete the TREND This item is used to delete all of the trend data which is saved in the internal memory of Palmcare plus. Step 1 You can enter to the TREND DELETE setting mode if you press ENTER button ( ), after making a reverse the item 5.TREND DELET on the environment setting (SETUP) screen. Making a reverse the item 5.TREND DELETE by pressing UP/DOWN button. Press ENTER( ) button Step 2 You can use UP/DOWN ( / ) button for the item moving, and ENTER ( ) button for your choice. Step 3 You can return automatically to the SETUP screen if you choose the mode by ENTER button. And if you want to cancel the selection and return to the SETUP screen, you can go back to the SETUP screen with ESC( ) button. 35

36 CAUTION Please take a note that all of the trend data saved in the inside of Palmcare can be deleted, if you select YES 36

37 Select Language This item is used to select language of PalmCare plus. Step 1 You can enter to the Select Language setting mode if you press ENTER button ( ), after making a reverse the item 6.Select Language on the environment setting (SETUP) screen. Making a reverse the item 6. Select Language by pressing UP/DOWN button. Press ENTER ( ) button Step 2 You can use UP/DOWN ( / ) button for the item moving, and ENTER ( ) button for your choice. i. 1.English Lan : Select English ii. 2.French Lan : Select French iii. 3.Germeny Lan : Select Germeny vi. 4.Italian Lan : Select Italian. v. 5.Spain Lan : Select Spain. 37

38 Step 3 You can return automatically to the SETUP screen if you choose the mode by ENTER button. And if you want to cancel the selection and return to the SETUP screen, you can go back to the SETUP screen with ESC( ) button. 38

39 Information of Palmcare plus Palmcare plus displays the simple information of this equipment on the LCD like the manufacturer of Palmcare plus, Program version/name and etc. Step 1 You can check the information of Palmcare plus by pressing the ENTER button ( ) after making a reverse the item 7.Device Info. Making a reverse the item 7.Device Info by Up/Down button. Press ENTER ( ) button Step 2 You can use UP/DOWN ( / ) button for the item moving, and ENTER ( ) button for your choice. Brightness : LCD Brightness auto control setting. i. ON : If there is no key input, do setting Back Light is controlled automatically after 30 seconds (Auto Dim out). ii. OFF : If there is no key input, do not setting Back Light is controlled automatically after 30 seconds. Step 3 You can go back to the previous (SETUP screen) if you press ESC ( ) button. 39

40 Trend Function PalmCare plus Palmcare plus can show you the value at each time in the trend form which has been measured for1hr, 12hr, 24hr, 48hr and 72hr of the patients oxygen saturation (SpO2) and Pulse Rate (HR) That s to say, you can examine and print the long-term change and the previous data of the measurement value of the patient (However, the printing is possible only in case of attaching the printer on Palmcare plus. Trend Information Check Step 1 If you want to examine the trend information on the initial screen, please press TREDN button ( ) then the following Trend printing screen will be seen on the LCD. Press the TREND ( ) button 40

41 It indicates the type of the trend being displayed on the curren screen. 2 Time(hour: minute-it starts at 00:00) for initial trend saving time 3 Saved SpO₂value 4 Save HR Value 5 Event data which is saved by the user 6 Data mark which is saved by Medium Priority Alarm 7 Data mark which is saved by High Priority Alarm Step 2 You can examine the Trend Data by pressing the UP/DOWN button ( / ). Whenever pressing the TREDN button( ) one time, you can check Trend information as below 다. 1 hour SpO2/ Pulse Rage Trend - mean value of the 1 minute unit 12 hours SpO2/ Pulse Rage Trend - mean value of the 5 minutes unit 24 hours SpO2/ Pulse Rage Trend - mean value of the 10 minutes unit 48 hours SpO2/ Pulse Rage Trend - mean value of the 20 minutes unit 72 hours SpO2/ Pulse Rage Trend - mean value of the 30 minutes unit Step 3 You can go back to the initial screen if you press ESC button ( completing trend examination. ) after 41

42 Measuring of SpO₂ Preparation before Measuring SpO₂ Step 1 Plug in the SpO₂probe to SpO connection port on upper side of Palmcare plus. 1 Spo2 probe connection port Step 2 Turn the power on by pressing the power button ( ) PalmCare plus. Attaching of Probe Step 1) Clean the area of the body to be measured by using alcohol. Step 2) Attach the probe to a finger as shown on the following drawing. (When measuring NIBP, SpO2 probe is attached to the other arm than the one that NIBP is measured. Do not use with other medical instruments that can affect the blood flow, and do not attach the probe where medical interference can be generated.) Step 3) Be sure that red light of the probe is on, the sensor gives out the light, the both sides of the probe faces rightly Step 4) For a stable SpO2 measurement, movement of body should be restricted, and band the probe cable on the finger. When banding the probe cable, make sure it does not hinder with blood flow. Step 5) Make sure to check the skin condition in the attached location and the sensor whether they are facing each other in a proper way, every 2 to 3 hours. If skin condition changes, change the attaching location. SpO₂Finger Finger Banding 42

43 CAUTION (How to apply SpO₂finger probe) Make sure that you should carefully handle the sensor and cable. Non-careful use of the probe may cause harm the sensitive sensor. Be sure that the cable is protected against sharp things. If a patient suffers from a fever or a disorder in peripheral circulation system, then the temperature of the skin goes up by 2 or 3 degrees. If the values for Oxyhemoglobin or Methemoglobin of a patient are increased abnormally, the SpO2 data are not reliable. The disposable sensor should not be re-used for the same patient on the same or different part of the body. In order to reuse disposable sensor, you should sterilize it WARNING Using an SpO2 probe during MR imaging can cause severe burns. To minimize this risk, ensure that the cable is positioned so that no inductive loops are formed. If the probe does not appear to be operating properly, remove it immediately from the patient. Never apply an SpO2 probe at ambient temperatures higher than 37 Do not use disposable probe on patients who have allergic reactions to the adhesive Avoiding the probe placed on any extremity with an arterial catheter, or intravascular venous infusion line. Make sure the sensor emitter light and is directly opposite each other and that all of the light from the emitter passes through the patient s tissue. For Neonatal patients, make sure the disposable probe should be used outside the incubator. (The humid atmosphere inside the incubator can cause inaccurate measurements.) 43

44 Alarm Function Palmcare plus is designed to provide various kinds of alarm for users convenience. Users must read following carefully and treat proper manner in the situation of alarm occurrence. About the Alarm 1 High Priority Alarm The high priority alarm is set off only when a measured value is extremely abnormal. For example, in the event pulse rate goes up higher than 180 or goes down lower than 40, the high priority alarm will go off regardless of set alarm limits. It is recommended to actually listen to the alarm sound in advance for fast and accurate recognition.. 2 Medium Priority Alarm The medium priority alarm goes off when a measured value goes over the set alarm limits. It is recommended to actually listen to the alarm sound in advance for fast and accurate recognition. Medium priority alarm works in connection with the oxygen saturation and pulse rate. If the oxygen saturation and pulse rate exceeds the alarm limits, it becomes to activate. 3 Information Alarm Information Alarm informs the matters which the user should keep or the abnormality occurrence during measuring by alarming NOTE We are recommended to hear the each alarm sound with your own ears before use the equipment, because to express the sound is very hard. Alarms for Each Mode 1 Standard Mode The high priority alarm makes a sound 5 times in the period of 2 seconds, and then after interval of 10 seconds, it makes a sound again 44

45 5 times in 2 seconds. This alarm sound has a rhythm specified by the international standards. The medium priority alarm makes a 3 times in the period of 2 seconds and then after interval of 24 seconds, it makes a sound 3 times in 2 seconds. If the information alarm goes off, it means that incidences as follow have occurred. i. Heart beating : The pitch of beep sound will vary in accordance with oxygen saturation value changes. ii. In case the battery capacity is running out: when inside battery is used instead of outside power source (DC adapter), the information (warning) alarm will go off to alert the user, when the battery is running out. iii. In case of Measuring failure: When a sensor has slipped off, or when a probe connector is pulled off from the equipment, or when sensor is malfunctioning, the information alarm will go off. 2 Visual Alarm To provide the fast recognition at a glance by the users, all the displayed values that caused the alarm will be set to blink continuously Alarm Occurrence In the event the alarm occurs, the measured value changed red color and you can heard the alarm weaning sound at the same time. 45

46 Power & Battery Specifications PalmCare plus can be operated DC power. It can be operated while on the move by getting the power from the internal battery which ca be used again by recharging with the DC adapter. DC Adapter Power In case battery power is running out, it is automatically recharged if you connect DC adapter to Palmcare plus to the outlet. 1. USB (mini B Type) Communication connector 2. DC Adapter connector Battery Power The internal battery supplies the sources of electricity, if you separate the Dc adapter from Palmcare plus. - Recharging period : 1Houres 1H/2 Min(1CELL),3 hours (2CELL) - Continuous operating time : 3 hours(1cell: 1130mAh)- Standard 6hours (2CELL: 2260mAh)-Optional NOTE In case battery power is running out, battery shaped icon ( ) will blink at the upper portion of the LCD screen before about 5 minutes of the power shortage. And the power can be immediately turned off according to the using parameter. Therefore, DC power has to be supplied at once. For the effective use of battery, Palmcare plus has the power saving mode it turn off the LCD back light after 3 seconds and also turn off the all functions of Palmcare plus after 30 seconds, if the user does not operate any button or measures. (However, if he starts operating any button or measurement within 30 seconds, the LCD back light turns on again) But it will not turn off the power if the AC adapter is connected. 46

47 Both AC and DC power is used for PalmCare plus. Basically, AC power is used and a rechargeable battery is available for portable use. 1. AC Power (110~240VAC) If the AC power is connected to the main body of the product, If the product is not being used, the power changes automatically to the recharging mode. A. Type of Adaptor - Model : JMW110KA0500M03 Input : 100~240V~, 50~60Hz - Output : 5V(DC), 2Amps - Manufacturer: BridgePower Corp. CAUTION During operation using AC power, noise may occur in the waveform. If this is the case, ground the product soundly. An AC power connection in a wet or damp area may cause electric shock or fatal damage to the product. When you connect the adapter will charge the battery automatically 2. Battery Specifications When the AC power is disconnected and the switch is turned on, the power is supplied using the battery. A. Signs for Battery Battery status Description Battery full After use for 70 ~ 80 minutes Requiring recharging Low Battery requiring recharging B. Time for 1ea of battery 47

48 Recharging time: 1H 1H/2Min,3H(OP MODE),(2H,4H)(POWER OFF) Use time : 180 Min,360 MIN CAUTION When the battery is removed, all data can be reset. Only in case the product is kept for long time, Remove the battery from the product B. Natural lifetime for spontaneous discharge of battery The table below shows the lifetime for spontaneous discharge of the battery when the product is unused. Storage temperature Life for spontaneous discharge 0 ~ 20 9 months 21 ~ 30 6 months 31 ~ 45 3 months D. Type of Battery The same sort of battery should be used for replacement. - Model : 1S1P(ICP523450)/ Type : LI-Ion / Manufacturer: ENERWIZ E. Time for the Battery exchange The lifetime of the battery gets shorter if it is not 100% recharged for use. Charge / Discharge ration Number for use 100 % Charge / discharge 1200 times 50 % Charge / discharge 500 times 30 % Charge / discharge 200 times 48

49 CUATION For the protection of the environment, please contact the agency you purchased the product from when you wish to discard the battery. Contact the agency you purchased battery in case battery should be changed. To ensure the lifecycle and safety of battery, please discharge the battery and then charge perfectly again every six months. Also time-worn battery exceed 24 months should be replaced. Before Requesting After Service This chapter explains the solutions to simple problems occurred during the operation. One might feel lost sometimes while operating the equipment. You don t need to call the service man every time you feel lost. It just might be a simple operational problem. Before you call for help, check the following points. Problem Cannot turn the Power on. Solution 1. In case of the battery is discharged. - Connect DC adapter. 2. Please check the connection of the switch, it happens when the switch junction is imperfect. The red light in the sensor is extinguished. The wave does not display normally. 1. Please check the connection of the probe, it happens when the probe junction is incomplete. 2. Please replace the probe, it happens for the defective probe. 1. Please check the connection of the probe, it happens when the probe is put in infirmly. For repair, contact our Customer Service Dept, or A/S receptions. 49

50 Product Specification Display TFT COLOR LCD Resolution : 320 X 240 Pixels Graphic wave form 10 level vertical bar graph Numeric Data Display : Current Oxygen Saturation, Pulse Rate Display Mode: Horizontal or Vertical display Indicators Low Battery Icon SpO₂No Sensor, No Finger Icon SpO₂Pulse Search Icon Low Perfusion Icon Alarm ON/Off Icon Screen Mode Icon Language Mode Icon Sound Mode Icon High Ambient Icon Measurement Range SpO₂Saturation: 0 ~ 100 % HR : 30 ~ 300 BPM Alarm Limits Range 50

51 Setting Default Value Range HI LOW HI LOW HR LOW+1 ~ ~ HI-1 SpO₂ LOW+1 ~ 100, OFF 1 ~ HI-1 Accuracy SpO₂ : 70 ~ 100 % (1%step) : ±2% Under 70 % : unspecified Pulse Rate : 30 ~ 300 BPM : ±2% or ±2 bpm Power Consumption Manufacturer: BridgePower Corp. Model : JMW110KA0500M03z 100~240VAC, 50/60 Hz DC 5V Adaptor Battery Lithum-ion 3.7V 1CELL (1130mAh) Option 2CELL(2260mAh) 3hours on a full charge (1CELL) 6hours on a full charge (2CELL) Output USB mini Port: SpO₂, Pulse Rate Interface : USB mini B Type Temperature Range Operating : 50 ~ 113 (10 ~ 40 ) Storage: 14 ~ 122 (-10 ~ 50 ) Humidity Range Operating : 30% ~ 85% non condensing Storage : 20% ~ 95% non condensing 51

52 SpO₂Sensor Adult finger probe SpO₂extension cable (Optional : 2.4m(8ft)) Trend Memory Oxygen Saturation and Pulse rate Memories (72 hours maximum) Physical Dimension 165mm(H) X 70mm(W) X 30mm(D) 1CELL 200 g 2CELL 250 g Standard Accessories Finger Probe 5V, 2.0A DC Adapter Optional Accessories USB mini B Type Cable Disposable Probe Cradle Extension cable of SpO₂ (2.4m / 8.4ft) Product specification listed on the manual are subject to change according to the our design change procedure without notice. 52

53 Product Warranty Product Name Model Code Pulse Oximeter PalmCare plus Manufacture Approval No. No Manufacture Approval Date JAN Manufacture Serial No. No Warranty Period One year after the purchase date Purchase Date Date Month Year Customer Information Name of Hospital Address Name Tel Tel) Fax) Name of Distributor Name of Manufacture BIONICS Co., Ltd. Thank you for purchasing PalmCare plus. This product is under thorough quality management and complied with strict test. This product can be repaired, replaced or refunded in accordance with Customer s Damage Compensation Regulation noticed by Economic Planning Board. This product is medical equipment. Date : FEB. 15,

54 54

ANGELUS (Ver 2.03) Patient Monitoring System

ANGELUS (Ver 2.03) Patient Monitoring System ANGELUS (Ver 2.03) Patient Monitoring System CONTENT Contents of Manual 1 Meaning of Symbols used in this manual 2 Section 1. GENERAL 3 1.1 Introduction 4 1.2 Composition of unit 8 1.3 Panel Description

More information

End-Tidal CO2 User Guide CAPNO3 T NIBP. SpO2. Ver Charmcare Co., Ltd.

End-Tidal CO2 User Guide CAPNO3 T NIBP. SpO2. Ver Charmcare Co., Ltd. End-Tidal CO2 User Guide CAPNO3 T NIBP EtCO2 ECG SpO2 Ver 2.00 Charmcare Co., Ltd. -1- Table of Contents Indications for use statement 4 Warranty 4 Battery Replacement 4 Contact Us 5 Definition of Terms

More information

Model 900. Pulse Oximeter User s Manual

Model 900. Pulse Oximeter User s Manual Model 900 Pulse Oximeter User s Manual MEDIAID INC. 17517 Fabrica Way Suite H, Cerritos, CA 90703 USA Phone: 714-367-2848; Fax: 714-367-2852 Website: www.mediaidinc.com POX010-900 Contents Table of Contents

More information

VS2000V Veterinary Vital Signs Monitor Operation Manual

VS2000V Veterinary Vital Signs Monitor Operation Manual VS2000V Veterinary Vital Signs Monitor Operation Manual - English Version 1.0, July 2011 2011 UTECH Co., Ltd. All rights reserved. Table of Contents Table of Contents Warranty and Service Information...

More information

Nellcor Bedside SpO 2 Patient Monitoring System, PM100N

Nellcor Bedside SpO 2 Patient Monitoring System, PM100N Nellcor Bedside SpO 2 Patient Monitoring System, PM100N In-Service Presentation Nellcor Bedside SpO 2 Patient Monitoring System is CE marked and commercially av ailable in European Union countries. Nellcor

More information

CLEO VERSATILITY IN VITAL SIGNS

CLEO VERSATILITY IN VITAL SIGNS CLEO VERSATILITY IN VITAL SIGNS CLEO PORTABLE weighs less than 3 lbs TOUCHSCREEN easy and intuitive to use MOBILE backup battery powered The Cleo is a new and intuitive approach to patient vital signs

More information

MODEL 3X Series User s Manual

MODEL 3X Series User s Manual MODEL 3X Series User s Manual Pulse Oximeter with options for 24 hour Memory, Printer & USB / Infrared Ports MEDIAID INC. 17517 Fabrica Way Suite H Cerritos, CA 90703 USA (Tel) 714-367-2848 (Fax) 714-367-2852

More information

TidalGuard HD. Handheld CO 2 / SpO 2 and CO 2 monitors. Operating Manual Rev. H (8/15)

TidalGuard HD. Handheld CO 2 / SpO 2 and CO 2 monitors. Operating Manual Rev. H (8/15) TidalGuard HD Handheld CO 2 / SpO 2 and CO 2 monitors Operating Manual 003-2275-00 Rev. H (8/15) Table of Contents Table of Contents Service Information... iv Preface... vi 1. Safety... 1-1 1.1 Safety

More information

User Manual. Non-contact Infrared Thermometer.

User Manual. Non-contact Infrared Thermometer. User Manual Non-contact Infrared Thermometer www.paryvara.com info@paryvara.com Introduction Thank you for purchasing this Non-contact Infrared Thermometer. Please read the User Manual carefully to ensure

More information

OMNI Express VS VERSATILITY IN VITAL SIGNS

OMNI Express VS VERSATILITY IN VITAL SIGNS OMNI Express VS VERSATILITY IN VITAL SIGNS OMNI Express VS TOUCHSCREEN easy and intuitive to use PORTABLE weighs less than 6lbs MOBILE backup battery powered The Omni Express VS is a new intuitive approach

More information

HANDHELD PULSE OXIMETER

HANDHELD PULSE OXIMETER Attendant HANDHELD PULSE OXIMETER Owner s Manual Please keep and refer to this Owner s Manual. Thank you for purchasing an Attendant Handheld Pulse Oximeter from Direct Supply Equipment & Furnishings.

More information

IntelliVue Cableless Measurements

IntelliVue Cableless Measurements Instructions for Use IntelliVue Cableless Measurements CL SpO2 Pod CL NBP Pod CL Respiration Pod Release B.02 Patient Monitoring 1Table of Contents 1 Introduction and Basic Operation 5 Introducing the

More information

Syringe Pump. User Manual

Syringe Pump. User Manual Syringe Pump User Manual Specifications Length Height Width Weight Waterproof Rating Battery 30 cm 13 cm 12.5 cm 1.8 kg IPX3 Rechargeable Li Polymer 7.4 V 1900 mah 6 Hour Battery Life Running 3 Hours When

More information

About this Manual. Statement. Release Date: January, 2014

About this Manual. Statement. Release Date: January, 2014 About this Manual Release Date: January, 2014 Statement This manual will help you understand the operation and maintenance of the product better. It is reminded that the product shall be used strictly

More information

About this Manual. Statement. P/N: Release Date: August 2010 Copyright EDAN INSTRUMENTS, INC All rights reserved.

About this Manual. Statement. P/N: Release Date: August 2010 Copyright EDAN INSTRUMENTS, INC All rights reserved. About this Manual P/N: 01.54.110221-13 Release Date: August 2010 Copyright EDAN INSTRUMENTS, INC. 2008-2010. All rights reserved. Statement This manual will help you understand the operation and maintenance

More information

1 Appendix - Product Specifications

1 Appendix - Product Specifications 1 Appendix - Product Specifications WARNING The patient monitor may not meet its performance specification if stored or used outside the manufacturer s specified temperature and humidity range. 1.1 Safety

More information

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual MODEL: SP12C7 (Portable 4 gas detector) Operating Manual Guarantee and Repair Senko Co., Ltd. guarantees the products of SP series for 24 months from the shipping date and repairs or replaces the defected

More information

Health Frequency Therapy Device. Instruction Manual

Health Frequency Therapy Device. Instruction Manual Health Frequency Therapy Device Instruction Manual Precautions before use Make sure to follow the product instruction manual before opening or using Confirm whether the voltage is consistent Use the power

More information

OctiveTech 300AH HANDHELD OXIMETER OPERATING INSTRUCTIONS

OctiveTech 300AH HANDHELD OXIMETER OPERATING INSTRUCTIONS OctiveTech 300AH HANDHELD OXIMETER OPERATING INSTRUCTIONS Octive Technologies U.S.A. www.octivetech.com Contents CHAPTER1 INTRODUCTION...3 1.1 Brief Introduction...3 1.2 Safety Information... 3 1.3 Electromagnetism

More information

OPERATOR S MANUAL. NPB-4000/4000C Patient Monitor

OPERATOR S MANUAL. NPB-4000/4000C Patient Monitor OPERATOR S MANUAL NPB-4000/4000C Patient Monitor Nellcor Puritan Bennett Inc. is an affiliate of Tyco Healthcare. Nellcor, Nellcor Puritan Bennett, Durasensor, C-LOCK, Oxisensor II, Dura-Y, and the Nellcor

More information

OPERATOR S MANUAL. Patient Monitor M20. EU representative TECNOMED 2000 S.L. Valencia, Madrid Spain

OPERATOR S MANUAL. Patient Monitor M20. EU representative TECNOMED 2000 S.L. Valencia, Madrid Spain OPERATOR S MANUAL Patient Monitor M20 EU representative TECNOMED 2000 S.L. Valencia, 25-28012 Madrid Spain Manufacturer Mediana Co., Ltd. Wonju Medical Industry Park, 1650-1 Donghwa-ri, Munmak-eup, Wonju-si,

More information

Userʼs Manual MEDIAID INC.

Userʼs Manual MEDIAID INC. Userʼs Manual MEDIAID INC. 17517 Fabrica Way Suite H Cerritos, CA 90703 USA (Tel) 714-367-2848 (Fax) 714-367-2852 Email: info@mediaidinc.com Website: www.mediaidinc.com Model 31DT Pulse Oximeter User

More information

Propaq LT Outline Train the Trainer

Propaq LT Outline Train the Trainer Train the Trainer A. Propaq LT and LTR Propaq LT Standalone monitor Propaq LTR Monitor that has the wireless Acuity feature enabled 1. Lightweight (Less than 2 pounds) 2. Uses rechargeable lithium ion

More information

TORONTEK-B400 Pulse Oximeter. User Instructions

TORONTEK-B400 Pulse Oximeter. User Instructions User Instructions This Manual is written and compiled in accordance with the council directive MDD93/42/EEC for medical devices and harmonized standards. In case of modifications and software upgrades,

More information

GSM Smart Home Alarm Apparatus. [99+4 defense zones] Instruction for Use

GSM Smart Home Alarm Apparatus. [99+4 defense zones] Instruction for Use GSM Smart Home Alarm Apparatus [99+4 defense zones] Instruction for Use Table of content Ⅰ. Introduction to the system... 2 Ⅱ. Introduction to function... 2 Ⅲ. System composition and use method... 3 Ⅳ.

More information

Operator s Manual. LifeSense LS1-9R. Vital Signs Monitor. Capnography/Pulse Oximeter

Operator s Manual. LifeSense LS1-9R. Vital Signs Monitor. Capnography/Pulse Oximeter Operator s Manual Vital Signs Monitor Capnography/Pulse Oximeter LifeSense LS1-9R CAUTION: Federal law (USA) restricts this device to sale by or on the order of a licensed practitioner. Consult Instructions

More information

qube mini Overview

qube mini Overview D a t a S h e e t qube mini Overview The 91389 qube mini is a compact, robust, and light-weight patient monitor with extensive clinical usability. Key features of the qube mini monitor include: Eye-level

More information

Operator s Manual. Models 8600FO and 8600FOM Pulse Oximeters. English

Operator s Manual. Models 8600FO and 8600FOM Pulse Oximeters. English Operator s Manual Models 8600FO and 8600FOM Pulse Oximeters English CAUTION! CAUTION! Federal law (USA) restricts this device to sale by or on the order of a physician. Read this manual carefully before

More information

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual PT0E-0922 Portable Oxygen Monitor OX-07 (Type B) Operating Manual Request for the Customers Read and understand this operating manual before using this gas monitor. Use it in accordance

More information

N-600. Pulse Oximeter Home Use Guide

N-600. Pulse Oximeter Home Use Guide N-600 Pulse Oximeter Home Use Guide Important: Read this manual before using the monitor If you need help, call the 24-hour hotline of the medical equipment dealer listed below: Nellcor Puritan Bennett

More information

HUG.ai 1/24/06 9:33:34 AM HUG.ai 1/24/06 9:33:34 AM C M Y CM MY CY CMY K

HUG.ai 1/24/06 9:33:34 AM HUG.ai 1/24/06 9:33:34 AM C M Y CM MY CY CMY K HUG.ai 1/24/06 9:33:34 AM C M Y CM MY CY CMY K This ISM device complies with Canadian ICES-001. Cet appareil ISM est conforme à la norme NMB-001 Canada. Nellcor Puritan Bennett Inc. is an affiliate of

More information

901-M / 901-ML. Pulse Oximetry System. Technical Information and Service Manual

901-M / 901-ML. Pulse Oximetry System. Technical Information and Service Manual 901-M / 901-ML Pulse Oximetry System Technical Information and Service Manual CONTENTS 1. PRELIMINARY REMARK...... 4 2. FUNCTION DESCRIPTION......... 5 2.1. INTENDED USE...5 2.2. CONTRAINDICATION...5 2.3.

More information

SpotOn Temperature Monitoring System. SpotOn. Temperature Monitoring System. Model 370 Installation and Service Manual

SpotOn Temperature Monitoring System. SpotOn. Temperature Monitoring System. Model 370 Installation and Service Manual 3 SpotOn Temperature Monitoring System Model 370 Installation and Service Manual Please forward to the Biomedical Engineering Department 3M SpotOn Temperature Monitoring System Revision History Revision

More information

DPM Summary of Features and Benefits

DPM Summary of Features and Benefits Summary of Features and Benefits PAT I E N T M O N I TO R 12.1" TFT display, configurable up to 8 waveforms, enables maximum data analysis of your most critical parameters Standard features include 3/5-lead

More information

V202 HANDHELD PULSE OXIMETER OPERATING MANUAL QAB/V

V202 HANDHELD PULSE OXIMETER OPERATING MANUAL QAB/V V202 HANDHELD PULSE OXIMETER OPERATING MANUAL QAB/V202-1 0807 1. WARNINGS 4 2. INTRODUCTION 2.1 SpO2 Measurement Principles 5 2.2 Controls and Displays 6 3. ASSEMBLY 7 4. OPERATION 4.1 SpO2 and PR Monitoring

More information

Vitalmax 4000 CL Product Specifications

Vitalmax 4000 CL Product Specifications Page 1 of 5 Vitalmax 4000 CL 510 Garden Avenue North, Clearwater, FL 33755 Phone: (727) 442-8118 Fax: (727) 443-7257 A. Mechanical Description Size 10" H x 13" W x 8"D (25 cm x 33 cm x 20 cm) Weight 18

More information

Forehead Infrared Thermometer

Forehead Infrared Thermometer Forehead Infrared Thermometer Model 09-347 3-YEAR INSTRUCTION MANUAL ENGLISH & ESPAÑOL Please read this instruction manual completely before operating this unit. STOP! PLEASE ENSURE YOU HAVE ALL OF THE

More information

Syringe Pump Caddo 15B Learning Material Ver. 1.1 An ISO 9001:2008 company 94, Electronic Complex, Pardesipura Indore - 452 010 India Tel: +91-731 4211100 Fax: +91-731-2555643 e mail: info@scientech.bz

More information

TORONTEK-E400 Pulse Oximeter. User Instructions

TORONTEK-E400 Pulse Oximeter. User Instructions User Instructions This Manual is written and compiled in accordance with the council directive MDD93/42/EEC for medical devices and harmonized standards. In case of modifications and software upgrades,

More information

PATIENT MONITORING SYSTEMS

PATIENT MONITORING SYSTEMS PATIENT MONITORING SYSTEMS PATIENT MONITORING SYSTEMS The benefits of HEYER Scalis to meet the market situation HEYER Scalis function & features make it fit to match the requirement of standard applications

More information

N-600. Pulse Oximeter Operator s Manual

N-600. Pulse Oximeter Operator s Manual N-600 Pulse Oximeter Operator s Manual Nellcor Puritan Bennett Inc. is an affiliate of Tyco Healthcare. Nellcor, Oxiband, Durasensor, OxiCliq, Dura-Y, Max-Fast, SoftCare, and OxiMax are trademarks of Nellcor

More information

Infusion Pump Caddo 16B Learning Material Ver. 1.1 An ISO 9001:2008 company 94, Electronic Complex, Pardesipura Indore - 452 010 India Tel: +91-731 4211100 Fax: +91-731-2555643 e mail: info@scientech.bz

More information

HydroMaster USER S GUIDE HM-500

HydroMaster USER S GUIDE HM-500 HydroMaster USER S GUIDE HM-500 TABLE OF CONTENTS 1. INTRODUCTION... 2 A. Overview... 2 B. What s Included... 2 C. Housing Description... 2 D. Specification... 3 E. LCD Display... 4 F. Switch and Keypad

More information

Instructions for use / Alarm unit, Fiber optic cable & Sensor patch ENGLISH

Instructions for use / Alarm unit, Fiber optic cable & Sensor patch ENGLISH Instructions for use / Alarm unit, Fiber optic cable & Sensor patch ENGLISH Manufacturer: Redsense Medical AB Gyllenhammars väg 26 302 92 HALMSTAD SWEDEN www.redsensemedical.com These instructions are

More information

V203 HANDHELD PULSE OXIMETER & TEMPERATURE MONITOR OPERATING MANUAL

V203 HANDHELD PULSE OXIMETER & TEMPERATURE MONITOR OPERATING MANUAL V203 HANDHELD PULSE OXIMETER & TEMPERATURE MONITOR OPERATING MANUAL QAM/V203-1 1007 1. WARNINGS 4 2. INTRODUCTION 5 2.1 General 5 2.2 SpO2 Measurement principles 5 2.3 TEMP Measurement principles 5 2.4

More information

PULSE OXIMETER PACKAGE

PULSE OXIMETER PACKAGE instrumentation and software for research PULSE OXIMETER PACKAGE CANL-425SV-A USER S MANUAL DOC-095 Rev. 1.6 Copyright 2012 All Rights Reserved Med Associates Inc. P.O. Box 319 St. Albans, Vermont 05478

More information

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved. status 2016 Chuango. All Rights Reserved. Printed in China PA : AW1-UM-EN-V1.0 AW1 WiFi Alarm System User Manual Foreword Contents Congratulations on your purchase of the AW1 Alarm system. Before you commence

More information

signal extraction pulse oximeter OPERATOR S MANUAL

signal extraction pulse oximeter OPERATOR S MANUAL signal extraction pulse oximeter OPERATOR S MANUAL Signal Extraction Pulse Oximeter OPERATOR S MANUAL The Radical-7 Operating Instructions provide the necessary information for proper of all models of

More information

DC200 Digital Dispenser Operating Manual

DC200 Digital Dispenser Operating Manual DC200 Digital Dispenser Operating Manual 2015 Fisnar Phone: (973) 646-5044 E-mail: info@fisnar.com Table of Contents Product Safety Statements 4 Specifications 6 Accessories 6 External Controls 7 Machine

More information

OPERATOR S MANUAL. NELLCOR N-200 Pulse Oximeter

OPERATOR S MANUAL. NELLCOR N-200 Pulse Oximeter OPERATOR S MANUAL NELLCOR N-200 Pulse Oximeter To contact Nellcor s representative: In the United States, call 1-800-NELLCOR or 510 463-4000; outside of the United States, call Nellcor s local representative.

More information

Air to Water Heat Pump -Mono Control Unit. user manual. imagine the possibilities

Air to Water Heat Pump -Mono Control Unit. user manual. imagine the possibilities Control Unit RC120MHXGA RC140MHXGA RC160MHXGA RC090MHXEA RC120MHXEA RC140MHXEA RC160MHXEA Air to Water Heat Pump -Mono Control Unit user manual imagine the possibilities Thank you for purchasing this Samsung

More information

Lc~rlI. z - 510(k) Summary JUL

Lc~rlI. z - 510(k) Summary JUL JUL - 2 2008 Premarket Notification 510(k) Submission-5 10(k) Summary Report No. Report No. TE20071I01 I Lc~rlI 510(k) Summary z - This summary of 510(k) safety and effectiveness information is being submitted

More information

ELECTRIC AIR PUMP 130W INSTRUCTION MANUAL SPECIFICATIONS. ozito.com.au WHAT S IN THE BOX. Electric Air Pump. 3 x Inflation Adaptors

ELECTRIC AIR PUMP 130W INSTRUCTION MANUAL SPECIFICATIONS. ozito.com.au WHAT S IN THE BOX. Electric Air Pump. 3 x Inflation Adaptors WHAT S IN THE BOX ELECTRIC AIR PUMP 130W INSTRUCTION MANUAL SPECIFICATIONS Voltage: 220-240V ~50Hz Power: 130W Max. Current: 0.62A Max. Pressure: 0.6PSI Flow Rate: 440L/Min Inflation Time: Under 2min (double

More information

MD-MINI Dry Bath. Instruction Manual

MD-MINI Dry Bath. Instruction Manual MD-MINI Dry Bath Instruction Manual Catalog No. MD-MINI www.majorsci.com service@majorsci.com Version 01B Revision on: 2013.07.15 Packing list MD-MINI: 1x MD-MINI Dry Bath 1x MD-MINI Lid 1x Power Cord

More information

Alarm System SECURE AS 302

Alarm System SECURE AS 302 Alarm System SECURE AS 302 Operating Manual SECURE Light app now available! Table of Contents Before You Start.................................. 4 User Information....................................4

More information

Guide, Quick Start, Short, X-100 System

Guide, Quick Start, Short, X-100 System Rev. CR/CO Date Orig. A 9950 2/15/16 DH Guide, Quick Start, Short, X-100 System P/N LANGUAGE NONIN ELECTRONIC FILE FINALSIZE 10885-001 ENGLISH 10885-001.01.INDD 5.5 X 8.5 NOTE 1: a. MATERIAL: 100lb cover

More information

V6 Vital Signs Monitor User s Manual

V6 Vital Signs Monitor User s Manual V6 Vital Signs Monitor User s Manual Product Information Product Model: V6 Product Name: Vital Signs Monitor Manufacturer: GuangdongBiolightMeditech Co.,Ltd. After Service Contact Information: Address:

More information

Quick Reference Guide STAN S31 fetal heart monitor. Power ON/OFF. ST Analysis (Fetal ECG analysis)

Quick Reference Guide STAN S31 fetal heart monitor. Power ON/OFF. ST Analysis (Fetal ECG analysis) Quick Reference Guide STAN S31 fetal heart monitor Important! Read the STAN S31 User Manual. 1. 2. 3. 1 2 3 4 5 6 Transducer connectors 4. Function buttons Power switch 5. Information panel Fetal ECG (FECG)

More information

T1 BEDSIDE MONITOR GUIDELINE

T1 BEDSIDE MONITOR GUIDELINE APPENDIX A T1 BEDSIDE MONITOR GUIDELINE 5.23 Software Version This document is a guideline only to be used as an aid to comprehensive Inservice training. NAME: HOSPITAL: DATE: VALIDATOR: A. OVERVIEW 1.

More information

Product Specifications

Product Specifications 1.Safety Specifications 1.1Product Classification Class Type of protection against electric shock Specification Class I, with internal power supply Degree of protection against electric shock Anti-defibrillation:

More information

TruSat Pulse Oximeter

TruSat Pulse Oximeter GE Healthcare TruSat Pulse Oximeter User s Guide GE Healthcare TruSat Pulse Oximeter User s Guide 6050-0006-815 March 2005 Important Rx Only (USA) Attention! Consult the accompanying instructions, including

More information

Tissue-Tek TEC Plus Cryo Console OPERATING MANUAL

Tissue-Tek TEC Plus Cryo Console OPERATING MANUAL Tissue-Tek TEC Plus Cryo Console OPERATING MANUAL Sakura Finetek Japan Co., Ltd., Tokyo 103-0023, Japan Sakura Finetek U.S.A., Inc., Torrance, CA 90501, USA Sakura Finetek Europe B.V., Zoeterwoude, Netherlands

More information

Omni (K) PATIENT MONITOR

Omni (K) PATIENT MONITOR Omni (K) PATIENT MONITOR Omni (K) Intuitive Designed for a fast paced work environment, the Infinium Omni (K) patient monitor offers an extremely simple and adaptable user interface. Patient information

More information

Dryer Controller M720

Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 2.00 Software version 2.00 Manual M720 Dryer controller Page 1 of 60 Document history Preliminary version: - Created in April, 2009 Hardware Version 2.00,

More information

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner alleru-buster F566894 Operating Instructions Air Conditioner Indoor Unit CS-RE9JKR CS-RE1JKR Outdoor Unit CU-RE9JKR CU-RE1JKR ENGLISH ~ 7 Before operating the unit, read these operating instructions thoroughly

More information

OMNI TOUCH SCREEN PATIENT MONITOR

OMNI TOUCH SCREEN PATIENT MONITOR OMNI TOUCH SCREEN PATIENT MONITOR OMNI Intuitive Designed for a fast paced work environment, the Infinium Omni patient monitor offers an extremely simple and adaptable user interface. Patient information

More information

Operating Instructions

Operating Instructions Operating Instructions Air Conditioner Model No. Indoor Unit CS-PC9QKH CS-PC12QKH CS-PC18QKH CS-PC24QKH CS-PC28QKH Outdoor Unit CU-PC9QKH CU-PC12QKH CU-PC18QKH CU-PC24QKH CU-PC28QKH Operating Instructions

More information

Manufacturer s Responsibility Only under the following circumstances will manufacturer be responsible for the safety, reliability and performance of t

Manufacturer s Responsibility Only under the following circumstances will manufacturer be responsible for the safety, reliability and performance of t Preface Thank you for using M9500 patient monitor. In order to enable you to skillfully operate Monitor as soon as possible, we provide this user s manual with delivery. When you install and use this instrument

More information

WIRELESS TEMPERATURE & HUMIDITY STATION INSTRUCTION MANUAL

WIRELESS TEMPERATURE & HUMIDITY STATION INSTRUCTION MANUAL WIRELESS TEMPERATURE & HUMIDITY STATION INSTRUCTION MANUAL MODEL: S82967 DC: 071118 FIND MANUALS, FAQS, AND MORE UNDER THE SUPPORT TAB HERE: www.lacrossetechnology.com/s82967 TABLE OF CONTENTS 3. Power

More information

Model 5340V Pulse Oximeter for Veterinary Use

Model 5340V Pulse Oximeter for Veterinary Use Model 5340V Pulse Oximeter for Veterinary Use User s Manual MEDIAID INC. 17517 Fabrica Way Cerritos California 90703 USA Tel.: 714-367-2848 Fax: 714-367-2852 Web: www.mediaidinc.com Email: info@mediaidinc.com

More information

Operator s Manual. Avant Digital Pulse Oximeter. English

Operator s Manual. Avant Digital Pulse Oximeter. English Operator s Manual Avant 9600 Avant 9600 Digital Pulse Oximeter 0123 English 1 Declaration of Conformity Manufacturer: Nonin Medical, Inc. Address: 2605 Fernbrook Lane North Plymouth, Minnesota 55447-4755

More information

Installation and operation manual

Installation and operation manual Installation and operation manual - + BRC1HHDAW BRC1HHDAS BRC1HHDAK English Table of contents Table of contents 1 General safety precautions 2 1.1 For the user... 2 1.2 For the installer... 2 2 About this

More information

M9500 Patient Monitor User s Manual

M9500 Patient Monitor User s Manual M9500 Patient Monitor User s Manual Guangdong Biolight Meditech Co., Ltd. Address: Innovation First Road, Technology Innovation Coast, Jinding, Zhuhai, P.R.CHINA Tel: +86-756-3399900 Fax: +86-756-3399989

More information

General safety precautions English

General safety precautions English English A min (m 2 ) 550 530 540 510 520 490 500 470 480 450 460 430 440 410 420 390 400 370 380 350 360 330 340 310 320 290 300 270 280 250 260 230 240 210 220 190 200 170 180 150 160 130 140 110 120

More information

Visit us at testo 835 Infrared and contact thermometer

Visit us at   testo 835 Infrared and contact thermometer 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com testo 835 Infrared and contact thermometer Instruction manual 1. General information

More information

General safety precautions English

General safety precautions English English A min (m 2 ) 550 530 540 510 520 490 500 470 480 450 460 430 440 410 420 390 400 370 380 350 360 330 340 310 320 290 300 270 280 250 260 230 240 210 220 190 200 170 180 150 160 130 140 110 120

More information

CLETEF-786. Infrared Thermometer Instruction Manual

CLETEF-786. Infrared Thermometer Instruction Manual CLETEF-786 0482 Infrared Thermometer Instruction Manual Introduction Thank you for choosing the Clever Choice Duo TM Ear & Forehead Thermometer, by Simple Diagnostics. The infrared thermometer CLETEF-786

More information

Model 7500 Model 7500

Model 7500 Model 7500 Operator s Manual Model 7500 Model 7500 Digital Pulse Oximeter 0123 English 1 CAUTION: Federal law (USA) restricts this device to sale by or on the order of a licensed practitioner. Consult Instructions

More information

Washing Machine. User manual WW9*K5*****/WW8*K5*****/WW7*K5***** Untitled :17:40

Washing Machine. User manual WW9*K5*****/WW8*K5*****/WW7*K5***** Untitled :17:40 Washing Machine User manual WW9*K5*****/WW8*K5*****/WW7*K5***** Untitled-6 1 2017-12-12 3:17:40 Contents Contents 4 What you need to know about the safety instructions 4 Important safety symbols 4 Important

More information

Operating manual Reusable Pulse Oximetry Sensors

Operating manual Reusable Pulse Oximetry Sensors Operating manual Reusable Pulse Oximetry Sensors FingerClip, Earclip, Multisite Wrap, Multisite Y, SoftTip plus (autoclavable), SoftTip 006-07-GA_SpO2_sensors_reusable-1 1002237 DEU GBR DNK GRC ESP HUN

More information

Operating Instructions Air Conditioner

Operating Instructions Air Conditioner F566113 Operating Instructions Air Conditioner Indoor Unit CS-E18HKR CS-E1HKR CS-E4HKR CS-E8HKR Outdoor Unit CU-E18HKR CU-E1HKR CU-E4HKR CU-E8HKR Before operating the unit, read these operating instructions

More information

Operator s Manual. Avant Digital Pulse Oximeter. English

Operator s Manual. Avant Digital Pulse Oximeter. English Operator s Manual Avant 9700 Avant 9700 Digital Pulse Oximeter 0123 English 1 CAUTION! CAUTION! Federal law (USA) restricts this device to sale by or on the order of a physician. Read this entire manual

More information

HANDY OX HAND HELD PULSE OXIMETER INSTRUCTION MANUAL. Model # 18715

HANDY OX HAND HELD PULSE OXIMETER INSTRUCTION MANUAL. Model # 18715 HANDY OX HAND HELD PULSE OXIMETER INSTRUCTION Model # 18715 Contents 1 Introduction... 3 1.1 Brief Introduction... 3 1.2 Safety Information... 3 1.3 Equipment symbols... 8 1.4 Electromagnetism interference...

More information

THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE SPECIFICATIONS OF THE PRODUCT WITHOUT PRIOR NOTIFICATION

THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE SPECIFICATIONS OF THE PRODUCT WITHOUT PRIOR NOTIFICATION No Touch Thermometer Instant INSTRUCTION MANUAL THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE SPECIFICATIONS OF THE PRODUCT WITHOUT PRIOR NOTIFICATION FEATURES 1. The No Touch Thermometer Instant is

More information

status AW1 Plus WiFi Alarm System User Manual

status AW1 Plus WiFi Alarm System User Manual status AW1 Plus WiFi Alarm System User Manual Foreword Congratulations on your purchase of the AW1 Plus Alarm system. Before you commence installation we recommend that you unpack the product, familiarise

More information

NexSysLink. 2 CAN Display Operation Manual. CAN Instruments Product Family

NexSysLink. 2 CAN Display Operation Manual. CAN Instruments Product Family NexSysLink CAN Instruments Product Family 2 CAN Display Operation Manual Contact Beede Beede Electrical Instrument Company, Inc. 88 Village Street Penacook, NH 03303 (603) 753-6362 Toll-free 800-451-8255

More information

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017 MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER August 2017 MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER August 2017 ii STATEMENT OF WARRANTY Ludlum Measurements, Inc. warrants the products covered

More information

Nellcor Puritan Bennett Inc. is an affiliate of Tyco Healthcare. Nellcor, Oxiband, Durasensor, OxiCliq, Dura-Y, MAX-FAST, and OXIMAX are trademarks

Nellcor Puritan Bennett Inc. is an affiliate of Tyco Healthcare. Nellcor, Oxiband, Durasensor, OxiCliq, Dura-Y, MAX-FAST, and OXIMAX are trademarks Nellcor Puritan Bennett Inc. is an affiliate of Tyco Healthcare. Nellcor, Oxiband, Durasensor, OxiCliq, Dura-Y, MAX-FAST, and OXIMAX are trademarks of Nellcor Puritan Bennett Inc. This ISM device complies

More information

AIR CONDITIONER OPERATING MANUAL. Duct type. Indoor Unit ARTG45LDTA ARTG54LDTA ARTG60LDTA KEEP THIS MANUAL FOR FUTURE REFERENCE. PART No.

AIR CONDITIONER OPERATING MANUAL. Duct type. Indoor Unit ARTG45LDTA ARTG54LDTA ARTG60LDTA KEEP THIS MANUAL FOR FUTURE REFERENCE. PART No. AIR CONDITIONER OPERATING MANUAL Duct type Indoor Unit ARTG45LDTA ARTG54LDTA ARTG60LDTA KEEP THIS MANUAL FOR FUTURE REFERENCE PART No. 98067 98067_OM_EN.indd 07-Aug-5 :40:5 OPERATING MANUAL PART No. 98067

More information

BIG DISPLAY ALARM CLOCK USER MANUAL

BIG DISPLAY ALARM CLOCK USER MANUAL 105mm(W) x 140mm(H) BIG DISPLAY ALARM CLOCK USER MANUAL Table of Contents Functions 2 Important Safeguards 2-3 Battery Safety 3-4 Parts 4-5 Before First Use 5 Power Supply 6 Inserting Battery 6 Basic Operations

More information

DINAMAP ProCare Monitor. Operation Manual

DINAMAP ProCare Monitor. Operation Manual DINAMAP ProCare Monitor Operation Manual Contents Introduction About the DINAMAP ProCare Monitor...7 Indications...7 Contraindications...7 Warnings... 8 Cautions...9 Product Compliance...10 Symbols...11

More information

Analog Room Pressure Monitor RPC Series

Analog Room Pressure Monitor RPC Series Description The Room Pressure Monitor is used to measure differential pressure in the range of 0.125 to 1"wc or 30 to 250 Pa. It combines precision high sensitivity silicon sensing capabilities and the

More information

E1000 Portable gas detector

E1000 Portable gas detector E1000 Portable gas detector Operation manual Ver:HWWM161229CG Read this manual carefully before using the device Table of Contents SAFETY INFORMATION... - 1-1. BRIEF INTRODUCTION... - 3-2. MAIN FUNCTION

More information

User Guide. Cardell Insight Veterinary Monitor. For Models: 8014 Blood Pressure Blood Pressure, Pulse Oximetry

User Guide. Cardell Insight Veterinary Monitor. For Models: 8014 Blood Pressure Blood Pressure, Pulse Oximetry Cardell Insight Veterinary Monitor For Models: 8014 Blood Pressure 8015 Blood Pressure, Pulse Oximetry User Guide 003-2981-00 Rev. B (2/21/17) Software Version 1.2V Product Information Dealer: Date of

More information

IMR EX610. Portable Gas Detector. Operation Manual

IMR EX610. Portable Gas Detector. Operation Manual IMR EX610 Portable Gas Detector Operation Manual IMR Environmental Equipment, Inc. 3634 Central Ave. St. Petersburg, FL 33711 Phone: 727-328-2818 email: info@imrusa.com Read this manual carefully before

More information

Infrared Thermometer

Infrared Thermometer 572-2 Infrared Thermometer PN 4307046 March 2013, Rev. 1, 08/13 2013 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their

More information

Safe Operation Manual. Honeywell IQ Force Gas Detector

Safe Operation Manual. Honeywell IQ Force Gas Detector Safe Operation Manual Honeywell IQ Force Gas Detector Honeywell Analytics 800-663-4164 403-248-9226 Fax 403-575-3708 03JUN2012 P/N 50105843-047 Version 01 http://www.honeywell.com HONEYWELL IQ Force PERSONAL

More information

Quick start guide. English

Quick start guide. English Quick start guide English Read your entire Astral User Guide or Clinical Guide before use. The Astral device 1. Adapter port Can be fitted with single limb adapter, single limb leak adapter or double limb

More information

High Resolution Display WIRELESS COLOR WEATHER STATION

High Resolution Display WIRELESS COLOR WEATHER STATION High Resolution Display WIRELESS COLOR WEATHER STATION Model: S88785 Instruction Manual DC: 070717 SIDE VIEW FRONT VIEW Outdoor Temp, humidity + Trends AC Power Jack DC 5.0V Day/Night Forecast + Trend

More information

V60. Manual. Pulse Oximeter QAM.V

V60. Manual. Pulse Oximeter QAM.V V60 Pulse Oximeter Manual QAM.V60.0915.4 2 INTRODUCTION 4 1. SAFETY 5 2. OVERVIEW 7 3. PRINCIPLE OF OPERATION 8 4. TECHNICAL DATA 9 5. INSTALLATION 10 6. OPERATION 12 7. MAINTENANCE TRANSPORTATION AND

More information