UN Test Report - ASM P/N 42T4882 (Nom. 63Wh, 11.1V)-

Size: px
Start display at page:

Download "UN Test Report - ASM P/N 42T4882 (Nom. 63Wh, 11.1V)-"

Transcription

1 문서번호 Prepared Reviewed Approved QAEEF PKASM P/N 42T4882 김홍일안경봉남익현남대호최운기정준용 UN Test Report ASM P/N 42T4882 (Nom. 63Wh, 11.1V) 목차 1. UN Transportation Regulation Test 2. Test Procedure 3. Test 4. Sample Image

2 1. UN Transportation Regulation Test Test Test 1. Altitude Simulation Test 2. Thermal Test Test 3. Vibration Test 4. Shock Test 5. External Short Circuit Test 6. Impact Condition Storing at (low pressure)11.6kpa for 6hr at 20+/5 [5± 2,6hr 40±2,6hr,interval max. 30min] x 10cycle Storing at 20± 5 for 24h [Hz 200Hz Hz, in 15min] x 12 times x 3 direction 1) sinusoidal waveform with a logarithmic sweep 2) Hz 18Hz (maintaining 1gn) app. 50Hz (until 8gn) 200Hz (maintaining 8gn), 1.6mm total excursion Half sine shock (peak acceleration : 150gn, pulse duration : 6msec) x 6 (± x, y, z) direction x 3 cycle 100mΩ ext. shortcircuit at 55± 2 1hr continue after returning at 55± 2 Φ=15.8mm bar, 9.1kg mass, 61± 2.5cm height s Measuring mass before/ after each test (If M>5g, less than 0.1%) Measuring voltage before/ after each test (more than 90%) No leakage, no venting, no disassembly, no rupture, no fire No disassembly, no rupture, no fire (after 6 hours) Temp. monitoring (max. 10 ) Test. Over Current = Manufacturer s recommended max. continuous current X 2 Voltage 1.If voltage 18V, V (min.) = 2 x (max. voltage) or V (min.) = 22V. 2.If voltage > 18V, V (min.) = 1.2 x (max. voltage) No disassembly, no fire (after days) Test 8. Forced Only for Cell, not battery. No disassembly, no fire (after days) * Tests through T1T5 shall be conducted in sequence with the same battery. * We declare that the abovementioned test is the result of being checked according to UN Test ( Manual of Test and Criteria ST/SG/AC.10/2/Add.2) QAEEF PKASM P/N 42T4882 [UN] Test Report (CMNote 6cell, C2) 1 / 6

3 2. Test Procedure Sample Sample Preparation Preparation Forced dis test is required to cell level, not pack battery level. Test 1 Test 1 Altitude Altitude Simulation Simulation Test 2 Test 2 Thermal Test Thermal Test Test 3 Test 3 Vibration Vibration Test 4 Test 4 Shock Shock Test 5 Test 5 Ext. Ext. Short Short Circuit Circuit 4 ea 1 st cycle d 4 ea 1 st cycle d 4 ea 50 th cycle d 4 ea 50 th cycle d 10ea 1 st cycle 50% d 10ea 50 th cycle d For cylindrical cells, 5 test cells are required. Test 6 Test 6 Impact Impact Test Test Over Over 4 ea 1 st cycle d 4 ea 50 th cycle d Test 8 Forced * 10ea 1 st cycle d 10ea 50 th cycle d Report Report QAEEF PKASM P/N 42T4882 [UN] Test Report (CMNote 6cell, C2) 2 / 6

4 31. T1T4 Test Before Altitude (T1) Thermal (T2) Vibration (T3) Shock (T4) Residual (%) Loss(%) Residual (%) Loss(%) Residual (%) Loss(%) Residual (%) Loss(%) A. 1st cycle fully state B. 50th cycle fully state Measuring mass before/after each test (If M>5g, less than 0.1%) Measuring voltage before/after each test (more than 90%, only d samples) No leakage, no venting, no disassembly, no rupture, no fire QAEEF PKASM P/N 42T4882 [UN] Test Report (CMNote 6cell, C2) 3 / 6

5 32. T5/T Test A. 1st cycle fully state EXT.Short Circuit (T5) B. 50th cycle fully state EXT.Short Circuit (T5) mΩ ext. shortcircuit at 55±2 Test Condition Temperature < 10 No disassembly, no rupture, no fire within 6 hours A. 1st cycle fully state Over (T) B. 50th cycle fully state Over (T) Test Condition Max. Current : 3800 ma CC/CV 2Imax(600mA) 16.8V cutoff 24Hr No disassembly, no fire within day QAEEF PKASM P/N 42T4882 [UN] Test Report (CMNote 6cell, C2) 4 / 6

6 33. T6 Test (ICR18650C2) Impact (T6) A. 1st cycle 50% state B. 50th cycle fully dis state Test Condition Φ=15.8mm bar, 9.1kg mass, 61±2.5cm height Temperature < 10 No disassembly, no rupture, no fire within 6 hours QAEEF PKASM P/N 42T4882 [UN] Test Report (CMNote 6cell, C2) 5 / 6

7 4. Sample Image QAEEF PKASM P/N 42T4882 [UN] Test Report (CMNote 6cell, C2) 6 / 6

UN Test Report - ASM P/N 42T4946, ASM P/N 42T4956 (Nom. 32Wh, 11.1V)-

UN Test Report - ASM P/N 42T4946, ASM P/N 42T4956 (Nom. 32Wh, 11.1V)- 문서번호 Prepared Reviewed Approved QAEEF02110122PKASM P/N 42T4946, 42T4956 김홍일안경봉남익현남대호최운기정준용 UN Test Report ASM P/N 42T4946, ASM P/N 42T4956 (Nom. 32Wh, 11.1V) 목차 1. UN Transportation Regulation Test 2.

More information

UN Test Report - ASM P/N 45N1010 (Nom. 94Wh, 11.1V)-

UN Test Report - ASM P/N 45N1010 (Nom. 94Wh, 11.1V)- 문서번호 Prepared Reviewed Approved QAEEF02111013PKASMP/N45N1010 김홍일남익현이문규남대호최운기정준용 UN Test Report ASM P/N 45N1010 (Nom. 94Wh, 11.1V) 목차 1. UN Transportation Regulation Test 2. Test Procedure 3. Test 4. Sample

More information

UN Test Report - ASM P/N 45N1028 (Nom. 94Wh, 11.1V)-

UN Test Report - ASM P/N 45N1028 (Nom. 94Wh, 11.1V)- 문서번호 Prepared Reviewed Approved QAEEF02111013PKASMP/N45N1028 김홍일남익현이문규남대호최운기정준용 UN Test Report ASM P/N 45N1028 (Nom. 94Wh, 11.1V) 목차 1. UN Transportation Regulation Test 2. Test Procedure 3. Test 4. Sample

More information

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector PRODUCT SPECIFICATION 108-115057 29OCT13 Rev. A1 0.5mm Fine Stacking Hermaphroditic Type BTB Connector 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for 0.5mm

More information

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT) Product 108-5390 Specification 31 OCT 17 Rev.F1 Free Height 0.8 mm Pitch Board-to-Board Connector (SMT) 1. SCOPE 1.1. Contents This specification covers the requirements for product performance, test methods

More information

23" PANEL MOUNT INDUSTRIAL MONITOR REVISION C PRODUCT RELIABILITY TEST REPORT

23 PANEL MOUNT INDUSTRIAL MONITOR REVISION C PRODUCT RELIABILITY TEST REPORT 23" PANEL MOUNT INDUSTRIAL MONITOR REVISION C PRODUCT RELIABILITY TEST REPORT Model No. HIS-ML23- _ C Table of Contents Test Report Overview... 3 Testing Rationale...3 Test Plan...4 Test 1 Cold (Steady

More information

17" UNIVERSAL MOUNT INDUSTRIAL MONITOR REVISION E, F & G PRODUCT RELIABILITY TEST REPORT

17 UNIVERSAL MOUNT INDUSTRIAL MONITOR REVISION E, F & G PRODUCT RELIABILITY TEST REPORT 17" UNIVERSAL MOUNT INDUSTRIAL MONITOR REVISION E, F & G PRODUCT RELIABILITY TEST REPORT Model No. HIS-UM17- _ E, HIS-UM17- _ F and HIS-UM17- _ G Table of Contents Test Report Overview... 3 Testing Rationale...3

More information

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE Cat. N STOP & GO automatic resetting 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat. N (s) : 4 062 88 / 4 062 89 CONTENTS PAGE 1. Description - Use... 1 2. Product

More information

1. Chemical Product and Company Identification

1. Chemical Product and Company Identification INR18650 Lithium-Ion Battery LG CHEMICAL LIMITED 1. Chemical Product and Company Identification Product Identification INR18650 Lithium-Ion Battery ( All models manufactured by LG Chem. ) Manufacturer

More information

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems Qualification Test Report 501-93032 14/April/2011 Rev A AMP-TWIST Series Jacks for Class EA systems 1. INTRODUCTION 1.1 Purpose Qualification testing on AMP-TWIST* Series Jacks for Class E A Systems, to

More information

Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616

Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616 TO WHOM IT MAY CONCERN Product Test report Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616 Product name: BOSCH FLEXIDOME IP indoor 4000 HD/IR BOSCH FLEXIDOME IP indoor

More information

Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616

Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616 TO WHOM IT MAY CONCERN Product Test report Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616 Product name: BOSCH FLEXIDOME IP outdoor 4000 HD/IR BOSCH FLEXIDOME IP outdoor

More information

Vibration tests on a TNAML Luminaire

Vibration tests on a TNAML Luminaire Sebert Trillingstechniek B.V. Report M13.001-P13.001 rev.01 Date 26 august 2013 Vibration tests on a TNAML Luminaire Client Technor Benelux B.V. Veersteeg 15 4212 LR Spijk The Netherlands Contact Person

More information

Plug shell and receptacle, single cavity, floating, EN Application of modular rectangular modules and shells per EN4165

Plug shell and receptacle, single cavity, floating, EN Application of modular rectangular modules and shells per EN4165 PRODUCT SPECIFICATION Sep 22, 29 Rev. B CONNECTOR, SINGLE CAVITY, AEROSPACE, PANEL MOUNT, FLOATING, EN416 1 - SCOPE 1.1. Content This document covers the performances, tests, and quality requirements of

More information

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka Last Amended on 07.10.2015 Page 1 of 18 I. EMC Test Facility 1. Electrical and Electronic Products, Process Control Devices, Lighting Control Products, Sensing and Control Devices, Electromechanical Products,

More information

DP86 Constant Voltage with Fitting

DP86 Constant Voltage with Fitting SPECIFICATIONS 316L SS Wet/Wet Differential Low Pressure 0 100mV Output The DP86 constant voltage with fitting differential pressure sensor is a double-sided, media compatible, piezoresistive silicon pressure

More information

ENVIRONMENTAL TEST REPORT

ENVIRONMENTAL TEST REPORT MECHANICAL TESTING 0839.04 Hermon Laboratories Ltd. Harakevet Industrial Zone, Binyamina 30500, Israel Tel. +972-4-6288001 Fax. +972-4-6288277 E-mail: mail@hermonlabs.com ENVIRONMENTAL TEST REPORT ACCORDING

More information

OCTOBER 4, 2013 C.O.C #213041B VITA 46 VPX CONNECTORS QUALIFICATION TESTING HYPERTRONICS CORPORATION

OCTOBER 4, 2013 C.O.C #213041B VITA 46 VPX CONNECTORS QUALIFICATION TESTING HYPERTRONICS CORPORATION OCTOBER 4, 2013 C.O.C #213041B VITA 46 VPX CONNECTORS QUALIFICATION TESTING HYPERTRONICS CORPORATION APPROVED BY: THOMAS PEEL PRESIDENT AND DIRECTOR OF TEST PROGRAM DEVELOPMENT CONTECH RESEARCH, INC. ATTLEBORO,

More information

/Mar/2014 Rev A

/Mar/2014 Rev A Qualification Test Report 501-93038 21/Mar/2014 Rev A MPOptimate FO Microcassette 12 fiber MPO-12xLC/PC 1. INTRODUCTION 1.1 Purpose Tests performed on MPOptimate FO Microcassette 12 fiber MPO-12xLC/PC,

More information

JUL 18 Rev A1

JUL 18 Rev A1 Qualification Test Report 501-166004 30 JUL 18 Rev A1 Mini USB-B Header, H-Type SMT 1. INTRODUCTION 1.1. Purpose Testing was performed on the Mini USB-B Header, H-Type SMT to determine if it meets the

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Crewe Road North Contact: Mr C Marshall Crewe Toll Tel: +44 (0)131 343 4242 Edinburgh Fax: +44 (0)131 343 5420 EH5 2XS E-Mail: chris.marshall@leonardocompany.com

More information

Product Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications :

Product Specification JUL07 Rev. F. 1. Scope : 2. Applicable Documents: 3. Requirements : 1 of Contents. 2.1 AMP Specifications : 1. Scope : 1.1 Contents 11JUL07 Rev. F DDR S.O.DIMM Socket 200 Positions This specification covers the requirements for product performance, test methods and quality assurance provisions of DDR S.O.DIMM

More information

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES

SPECIFICATION AND PERFORMANCE MDP CONNECTOR SERIES SPECIFICATION AND PERFORMANCE OF MDP CONNECTOR SERIES CIRCUIT ASSEMBLY CORP. 18 THOMAS STREET, IRVINE, CA 92618-2777 Page No. 1 of 16 CLAUSE CONTENTS PAGE 1.0 SCOPE... 3 2.0 APPLICABLE DOCUMENTS... 3 3.0

More information

Product Tests Report

Product Tests Report TO WHOM IT MAY CONCERN Page: 1 of 5 Product name: Model number and description: MIC IP starlight 7000i Product Tests Report MIC-7502-Z30B, PTZ camera 2MP HDR 30x IP68 IK10, black MIC-7502-Z30W, PTZ camera

More information

Mar11 Rev C

Mar11 Rev C Product Specification 108-1441 11Mar11 Rev C Connector, Z-PACK*, 2 mm FB, Signal and Power 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for the Z-PACK* 2mm

More information

Animals:Goats:Bleat.Calls,Warbling.Baa,Movements.Rubbing,Barn,Medium.Close,Interior,BG.Dog.Barks 01:21.618

Animals:Goats:Bleat.Calls,Warbling.Baa,Movements.Rubbing,Barn,Medium.Close,Interior,BG.Dog.Barks 01:21.618 Description Duration Animals:Goats:Bleat.Calls,Warbling.Baa,Movements.Rubbing,Barn,Medium.Close,Interior,BG.Dog.Barks 01:21.618 Animals:Goats:Herd,Bleat.Calls,Intensity.Increase,Warbling,Baby.Baa,Movements.Rubbing,Barn,Occasional.Dog.Barks,Medium.Close,Interior,BG.Crows.Squawks

More information

USB 3.0 Plug & Receptacle

USB 3.0 Plug & Receptacle US 3.0 Plug & Receptacle 1. Scope: 1.1 Contents: This specification covers the requirements for product performance, test methods and quality requirements of Tyco Electronics Universal Serial us (US) consortium

More information

Mar11 Rev B

Mar11 Rev B Product Specification 108-1576-2 11Mar11 Rev B NETCONNECT*, CHAMP* System 5 Modular Jack Patch Panel 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for NETCONNECT*

More information

Test Methods for Consideration Into Radio Standard

Test Methods for Consideration Into Radio Standard Test Methods for Consideration Into Radio Standard Jason Allen March 20,2013 Test Methods for Consideration Into Radio Standard Reviewed many current NFPA standards including: NFPA 1971- Structural and

More information

environmental chambers for Battery testing

environmental chambers for Battery testing environmental chambers for Battery testing www.cszproducts.com Battery Testing SOlutions We are a leading provider of environmental test chambers with over 78 years of industry experience in designing

More information

Battery Design Considerations

Battery Design Considerations Battery Design Considerations For general safety, and New York requirements Victoria Carey March 18, 2019 1 SAFER, SMARTER, GREENER DNV GL in Brief 155 350 14,000 2 DNV GL Energy Storage Expertise FEASIBILITY

More information

PERMANENT DOCUMENT. Annex AD to Routine Test Requirements for manufacturers (as per Article 9 of the Agreement)

PERMANENT DOCUMENT. Annex AD to Routine Test Requirements for manufacturers (as per Article 9 of the Agreement) PERMANENT DOCUMENT ENEC 303 Annex AD Annex AD to Routine Test Requirements for manufacturers (as per Article 9 of the Agreement) Household and similar electrical appliances covered by the EN 60335 series

More information

environmental chambers for Battery testing

environmental chambers for Battery testing environmental chambers for Battery testing www.cszindustrial.com Battery Testing SOlutions Cincinnati Sub-Zero (CSZ) is a leading provider of environmental test chambers with over 76 years of industry

More information

COMITÉ EUROPÉEN DES ASSURANCES

COMITÉ EUROPÉEN DES ASSURANCES COMITÉ EUROPÉEN DES ASSURANCES SECRETARIAT GENERAL 3bis, rue de la Chaussée d'antin F 75009 Paris Tél. : +33 1 44 83 11 73 Fax : +33 1 44 83 11 85 Web : cea.assur.org DELEGATION A BRUXELLES Square de Meeûs,

More information

ABB. Modular contactors. Contents

ABB. Modular contactors. Contents ABB Modular contactors Contents ESB... modular contactor Ordering details... 4/0 Technical data... 4/ Lighting application... 4/2 Dimensions... 4/4 EN... modular contactor Ordering details... 4/3 Technical

More information

Residual Current Devices

Residual Current Devices Residual devices F200 Series UL 1053 Residual devices F200 Series Residual Current Devices Description The F200 Series residual devices offer a wide range of product for all of your fault protection needs.

More information

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m

XUBLAPCNL2 photo-electric sensor - XUB - thru beam - laser - Sn 100m VDC - cable 2m Characteristics photo-electric sensor - XUB - thru beam - laser - Sn 100m - 12..24VDC - cable 2m Buy online Complementary Enclosure material Lens material Blind zone Output type Status LED [Us] rated supply

More information

Battery Design Considerations

Battery Design Considerations Battery Design Considerations For general safety, and New York requirements Victoria Carey March 12, 2018 1 SAFER, SMARTER, GREENER DNV GL in Brief 153 14,000 2 DNV GL Energy Storage Expertise FEASIBILITY

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60747-15 First edition 2003-06 Discrete semiconductor devices Part 15: Isolated power semiconductor devices Dispositifs à semiconducteurs Partie 15: Dispositifs à semiconducteurs

More information

Product Specification Mono-Shape TM Mark II - 5mm Pitch I.D.C Connectors, For TAB Contacts - RAST5

Product Specification Mono-Shape TM Mark II - 5mm Pitch I.D.C Connectors, For TAB Contacts - RAST5 1. SCOPE 1.1 Content This specification covers performance, test and quality requirements for the Mono-Shape Mark II - 5 mm Pitch I.D.C. Connectors for Tab contacts. These connectors are designed and developed

More information

M7100 Pressure Transducer

M7100 Pressure Transducer SPECIFICATIONS Performance standard on and off highway engine and vehicle OEMs Rugged for heavy equipment and outdoor use Designed specifically for high volume applications Stainless steel wetted surfaces

More information

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification Date: 2016.3.24 Scanning Laser Range Finder Smart-URG mini UST-10LN Specification Symbol Amended Reason Pages Date Corrector Amendment No Approved by Checked by Drawn by Designed by UST-10LN Specification

More information

Raychem Overvoltage Devices. ESD Protector PESD BENEFITS FEATURES APPLICATIONS MATERIALS INFORMATION PART NUMBERING.

Raychem Overvoltage Devices. ESD Protector PESD BENEFITS FEATURES APPLICATIONS MATERIALS INFORMATION PART NUMBERING. BENEFITS Suitable for high speed data transmission applications Longer battery life due to low leakage current Board space savings Help protect sensitive electronic circuits against electrostatic discharge

More information

DRAFT TANZANIA STANDARD

DRAFT TANZANIA STANDARD EDC 4 (5313) P3 DRAFT TANZANIA STANDARD (Draft for comments only) Specification for Handheld Metal Detectors for Use in Weapon Detection TANZANIA BUREAU OF STANDARDS TBS 2018 First Edition 2018 0 National

More information

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase General Specification 550 VA/Watts 1300 VA/Watts 1.0 GENERAL This specification defines the electrical and mechanical characteristics

More information

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits

VAMP 120 & 121. Arc Flash Protection Units. Arc Protection. Customer benefits 01 VAMP 120 & 121 Arc Flash Protection Units Customer benefits Personnel Safety A fast and reliable arc protection unit may save human lives in case of an arc fault arising in a switchgear during work

More information

KILOVAC K1K High-Voltage Contactor

KILOVAC K1K High-Voltage Contactor KILOVAC K1K High-Voltage Contactor High Performance in a Compact, Lightweight, Hermetically Sealed Contactor Designed for up to 1000 V/1000 A in Harsh Environments KILOVAC K1K High-Voltage Contactor Compact,

More information

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits

VAmP 120. Arc Flash Protection Units. Arc Protection. Customer benefits Arc Protection 01 VAmP 120 Arc Flash Protection Units Customer benefits Personnel Safety A fast and reliable arc protection unit may save human lives in case of an arc fault arising in a switchgear during

More information

D5100 Industrial Differential Pressure Transducer

D5100 Industrial Differential Pressure Transducer FEATURES Heavy Industrial CE Approval (amplified only) As Low As ±0.1% Pressure Non Linearity Rugged Construction: Can Withstand 50g Shock/20g Vibration Up to -40 C to +125 C Operating Temperature Range

More information

Technical Specification for the Mastic-Sealed Fiber-Optic Closure System (FOSC 300C)

Technical Specification for the Mastic-Sealed Fiber-Optic Closure System (FOSC 300C) Page 1 of 24 Prepared by: Chris Radelet R&D Department Manager Approved by: Pieter De Coster Product Manager for the Mastic-Sealed Fiber-Optic Closure System (FOSC 300C) The FOSC 300C closure system is

More information

DECOMMISSIONING OF THE REACTOR VESSEL OF THE COMPACT SODIUM COOLED NUCLEAR REACTOR FACILITY (KNK)

DECOMMISSIONING OF THE REACTOR VESSEL OF THE COMPACT SODIUM COOLED NUCLEAR REACTOR FACILITY (KNK) DECOMMISSIONING OF THE REACTOR VESSEL OF THE COMPACT SODIUM COOLED NUCLEAR REACTOR FACILITY (KNK) J. Benkert, F. Willman Westinghouse Electric Germany GmbH Mannheim / D K. Brockmann, I. Hillebrand Research

More information

APR 17 Rev A

APR 17 Rev A Product Specification 108-130015 11 APR 17 Rev A ChipConnect Cable Assembly 1. SCOPE 1.1. Content This specification covers performance, test and quality requirements for the ChipConnect Cable Assembly

More information

Osram OT 40 OT 60 OT 90 4DIMLT2 E LED Drivers Conformity check to Synergrid C4/10

Osram OT 40 OT 60 OT 90 4DIMLT2 E LED Drivers Conformity check to Synergrid C4/10 Restricted Osram OT 40 OT 60 OT 90 LED Drivers Conformity check to Synergrid C4/10 Version number Date Description and modification history LBE04109592-1.0 21/05/2015 New report Prepared for Synergrid

More information

Vacuum suction nozzle OVEM-...-1P/1N

Vacuum suction nozzle OVEM-...-1P/1N Vacuum suction nozzle OVEM-...-1P/1N Operating instructions (Translation of the original instructions) Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany +49 711 347-0 www.festo.com 8085608 2018-01b

More information

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h FANS FOR ROUND DUCTS Series VENTS ТТ PRO Series VENTS ТТ perform required servicing. All the models may be equipped with a regulated timer with turn-off delay adjustable from 2 to 30 min. TT PRO design

More information

Suction Controller SDR

Suction Controller SDR MB 00 / Constant suction pressure and leakage stop The suction controllers SDR 0 and SDR 00 have been developed because the flow rate of diaphragm metering pumps can be affected - among other factors -

More information

SENTINEL A - Fault Passage Indicator

SENTINEL A - Fault Passage Indicator SENTINEL A - Fault Passage Indicator AMPEREMETRIC FAULT PASSAGE INDICATORS FOR OVERHEAD MV NETWORKS Installed on poles of overhead lines, the Overhead-Sentinel-A range allows locating the fault arisen

More information

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description DPB52 True RMS 3-Phase, Multifunction monitoring relay Description Benefits Measuring Voltage Range. Very wide input voltage range: from 125 to 624V ( 208V 40% to 480 + 30% ). Adjustable Voltage Ranges

More information

EAE/EAES «HEPHEA 248» Product Technical Instructions

EAE/EAES «HEPHEA 248» Product Technical Instructions Page : 1/7 TABLE OF CONTENTS A. GENERAL FEATURES... 2 1. GENERAL INFORMATION... 2 2. DESIGN... 2 3. FUNCTIONAL FEATURES... 2 4. TECHNICAL FEATURES... 3 B. INSTALLATION AND CONNECTING... 4 1. SUPPLY UNIT

More information

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl enproteko.com Temperature Monitoring Relay K8AB-TH Compact and Slim Relay Ideal for Temperature Alarms and Monitoring Excessive increases can be prevented and abnormal s can be monitored. Temperature monitoring

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 62052-11 First edition 2003-02 Electricity metering equipment (AC) General requirements, tests and test conditions Part 11: Metering equipment This English-language version is

More information

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

Inline mixed-flow fans with the air capacity up to 450 m 3 /h FANS FOR ROUND DUCTS Series VENTS ТТ PRO Series VENTS ТТ perform required servicing. All the models may be equipped with a regulated timer with turn-off delay adjustable from 2 to 30 min. TT PRO design

More information

STT700 Temperature Transmitter Lightning Protection Device Specifications 34-TT-03-20, June 2017

STT700 Temperature Transmitter Lightning Protection Device Specifications 34-TT-03-20, June 2017 STT700 Temperature Transmitter Lightning Protection Device Specifications 34-TT-03-20, June 2017 Introduction The STT700 lightning protection device is designed to provide the Smart Temperature Transmitter

More information

FIS30XXseries Gas sensor module SPECIFICATIONS

FIS30XXseries Gas sensor module SPECIFICATIONS JDS COMPANY KOREA 02-3491-5217 www.jdscompany.co.kr FIS30XXseries Gas sensor module SPECIFICATIONS Model No. Product Name Spec. No. Issued on Applied product 1st edition FIS3091-99NC-01/03 Gas sensor module

More information

DYNAMICS WHILE DRILLING DWD SOLUTIONS LODESTARINT.COM

DYNAMICS WHILE DRILLING DWD SOLUTIONS LODESTARINT.COM DYNAMICS WHILE DRILLING DYNAMICS WHILE DRILLING The Lodestar suite of dynamics while drilling (DWD) tools allows customers to obtain the downhole data that enables them to create the most efficient and

More information

Technical Specification for the Gel-Sealed Fiber-Optic Closure System (FOSC 450)

Technical Specification for the Gel-Sealed Fiber-Optic Closure System (FOSC 450) Page 1 of 26 Prepared by: Daniel Daems R&D Department Manager Approved by: P. De Coster Product Manager for the Gel-Sealed Fiber-Optic Closure System (FOSC 450) The FOSC 450 system is a fully mechanical

More information

Table 1. Serie of Digital Room Thermostats.

Table 1. Serie of Digital Room Thermostats. Digital Room Thermostats INSTALLATION MANUAL APPLICATION DR is a serie of Digital Room Thermostats, provides a single stage, temperature control. Table 1 shows all the available models. All models can

More information

COMPLIANT MANAGER. Installation Manual. Model name: BMS-CM1280TLE BMS-CM1280FTLE. Save These Instructions! ENGLISH

COMPLIANT MANAGER. Installation Manual. Model name: BMS-CM1280TLE BMS-CM1280FTLE. Save These Instructions! ENGLISH COMPLIANT MANAGER Model name: BMS-CM1280TLE BMS-CM1280FTLE Save These Instructions! ENGLISH Contents 1 PRECAUTIONS FOR SAFETY........................................... 3 2 PACKAGED ITEMS OF COMPLIANT

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 COMPLIANCE ENGINEERING PTY LTD 90 Indian Drive Keysborough, Victoria 3173, AUSTRALIA Mr. Simon Grilj Phone: 61 3 9763 3079 Email: simon@compeng.com.au ELECTRICAL

More information

Emergency Lighting Control Gear Combo Economy Version (2 in 1)

Emergency Lighting Control Gear Combo Economy Version (2 in 1) Emergency Emergency Lighting Control Gear Combo Economy Version (2 in 1) HEM09/E / HEM09H/E Applications Suitable for LED panels - insulated terminal cover with cord restraint: Office / Commercial Lighting

More information

Part 3 Troubleshooting

Part 3 Troubleshooting Part Troubleshooting What is in this part? This part contains the following chapters: Chapter See page Troubleshooting 2 Error Codes: Hydro-box 7 Error Codes: Outdoor Units Error Codes: System Malfunctions

More information

ISO INTERNATIONAL STANDARD. Agricultural engineering Electrical and electronic equipment Testing resistance to environmental conditions

ISO INTERNATIONAL STANDARD. Agricultural engineering Electrical and electronic equipment Testing resistance to environmental conditions INTERNATIONAL STANDARD ISO 15003 First edition 2006-02-15 Agricultural engineering Electrical and electronic equipment Testing resistance to environmental conditions Génie agricole Matériel électrique

More information

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes 50-120 1 General The heat exchanger control system is a control system for 380 W step motors

More information

Specification , July 2015

Specification , July 2015 Technical Information PrecisionLine Controllers EDC21 / EDC22 / EDC23 EASYSET DIGITAL CONTROLLERS Specification 51-52-3-48, July 215 Introduction The EDC21, EDC22 and EDC23 controllers provide precise

More information

TB/T Translated English of Chinese Standard: TB/T RAILWAY INDUSTRY STANDARD

TB/T Translated English of Chinese Standard: TB/T RAILWAY INDUSTRY STANDARD Translated English of Chinese Standard: TB/T2296-2011 www.chinesestandard.net Sales@ChineseStandard.net RAILWAY INDUSTRY STANDARD TB OF THE PEOPLE S REPUBLIC OF CHINA ICS 45.020 S 60 TB/T 2296-2011 Replacing

More information

1 Appendix - Product Specifications

1 Appendix - Product Specifications 1 Appendix - Product Specifications WARNING The patient monitor may not meet its performance specification if stored or used outside the manufacturer s specified temperature and humidity range. 1.1 Safety

More information

Environment Test Report

Environment Test Report Environment Test Report Product Name: Product Model: Product Type: Power System TP48200A TP48200A-H15A3 TP48200A-H15A5 TP48200A-D15A1 Report Number: SYBH(H) 346052012 Reliability Laboratory of Huawei Technologies

More information

Replaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES

Replaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES Data Sheet 260.8 TIMER START I / O LOW-V SET TIMER OUT + SUPPLY TIMING RES. FEEDBACK 2 3 4 5 6 7 V DD LOGIC OSC. & TIMING DRIVER 8 V SS 9 ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS ) Supply

More information

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4 Table of Contents Page Quick Set-up Instructions 1 Theory of Operation 2 Specifications 3 TM 1003W Controls and Connections 4 1. Power Source Connector 5 2. Alarm Output Connector 5 3. Variation Detection

More information

Digital Heater Element Burnout Detector K8AC-H

Digital Heater Element Burnout Detector K8AC-H Digital Heater Element Burnout Detector K8AC-H A high-precision Heater Element Burnout Detector compatible with a wide-range of heater control methods. Push-in terminals reduce the workload. *1 Scaling

More information

TECHNICAL REPORT Crimp Splice Protection -250M/P150 mark 2

TECHNICAL REPORT Crimp Splice Protection -250M/P150 mark 2 FIBER OPTIC TECHNOLOGY CALIBRATION LABORATORY Document number: TZ_2_7_PP_EN_splice TECHNICAL REPORT Crimp Splice Protection -25M/P15 mark 2 E.G. Tec Ltd. Date: May-1-27 TZ_2_7_EN_splice Contents: 1. General...

More information

Accumulated Battery JULY The electronic pdf version of this document found through is the officially binding version

Accumulated Battery JULY The electronic pdf version of this document found through   is the officially binding version p pproval roramms for U rcos orasato Mutual coto (M)No. 2.9 STANDARD FOR CERTIFICATION Approval Programmes Type Approval Programmes for EU recognised organisation Mutual Recognition (MR) No. MR-E008 Accumulated

More information

D5100 Industrial Differential Pressure Transducer

D5100 Industrial Differential Pressure Transducer SPECIFICATIONS 316L Stainless Steel Wetted Surface Voltage, Current, and mv Outputs True Wet/Wet Differential CE Certified (amplified version only) Variety of Pressure Ports and Electrical Connections

More information

Technical Data Sheet Opto Interrupter ITR

Technical Data Sheet Opto Interrupter ITR Technical Data Sheet Opto Interrupter ITR Features Fast response time High sensitivity Cut-Off visible wavelength Thin Compact Pb free Descriptions /F43 is a light reflection switch which includes a GaAs

More information

Step by Step Detailed Procedure Expected Result Observations Verify power off at all loads on emergency power. Verify all loads have power.

Step by Step Detailed Procedure Expected Result Observations Verify power off at all loads on emergency power. Verify all loads have power. 1. ATS Breaker Open ATS Breaker Verify power off at all loads on emergency power. Close ATS Breaker & put ATS Sw. to Auto Verify all loads have power. 2. Generator Cold Open normal power breaker & immediately

More information

Products for Secondary Battery Market

Products for Secondary Battery Market Products for Secondary Battery Market Lithium-ion batteries Electrode blending process Materials are blended and processed to produce slurry for positive and negative electrodes. 1-1 Battery Dry Chamber

More information

Event Monitoring Device (EMD)

Event Monitoring Device (EMD) Event Monitoring Device (EMD) DRK-S701 INSTALLATION AND OPERATION MANUAL VERSION 2.2 - NOVEMBER 2015 PART NUMBER DRAM-BOOK DO NOT DISCARD! Contents Description Page Introduction/Features 2 Controls and

More information

Installation Instructions for W2H Series Signals

Installation Instructions for W2H Series Signals Installation Instructions for W2H Series Signals IF1513 A Description and Operation DIMENSIONS W2H A 8 7/8" (225 mm) B 8 1/4" (210 mm) C 13" (330 mm) Figure 1. Speaker/Amplifier Dimensions The W2H signaling

More information

DISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS

DISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS WITH INTERCONNECT Data Sheet 60.6 NO CONNECT. I / O LOW-V SET NO CONNECT. LED + SUPPLY TIMING RES. FEEDBACK 3 4 5 6 7 NC NC LOGIC OSC. & TIMING DRIVER 0 6 5 4 3 8 V SS GUARD DETECT. IN GUARD SENSITIVITY

More information

Qualification Test Report LC Duplex Adapter For LC Cutouts

Qualification Test Report LC Duplex Adapter For LC Cutouts Qualification Test Report LC Duplex Adapter For LC Cutouts 501-683 09Mar09 Rev B 1. INTRODUCTION 1.1. Purpose Testing was performed on Tyco Electronics LC Duplex Adapters for LC Cutouts, to determine their

More information

MICROJET RECORDER (24-CHANNEL 180mm)

MICROJET RECORDER (24-CHANNEL 180mm) MICROJET RECORDER (24-CHANNEL 180mm) DATA SHEET PHB This recorder can record a maximum of 24 channels of DC voltage, ma, thermocouples and resistance bulbs. The adoption of an ink jet system makes it possible

More information

EVAPORATIVE AIR COOLER

EVAPORATIVE AIR COOLER EVAPORATIVE AIR COOLER EN OPERATING INSTRUCTIONS Read the instructions carefully before operating the appliance or carrying out maintenance operations. Observe all the safety instructions; failure to observe

More information

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays To Be Discontinued IEC62055-31 UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays DZ RELAYS (ADZ) New New Horizontal terminal type FEATURES 1. IEC62055-31 UC3 compliant (short current

More information

EARTH LEAKAGE RELAY. User Manual - Issue 1.0

EARTH LEAKAGE RELAY. User Manual - Issue 1.0 Earth Leakage Relay www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters EARTH

More information

MODULAR CONNECTOR 154 (58 AND 96) POS, WATERPROOF PRODUCT SPECIFICATION

MODULAR CONNECTOR 154 (58 AND 96) POS, WATERPROOF PRODUCT SPECIFICATION MODULAR 154 (58 AND 96) POS, WATERPROOF PRODUCT SPECIFICATION 108-18965 Product Specification 108-18965 10.02. 2011 Rev C1 MODULAR 154 (58 AND 96) POSITION, WATERPROOF CONTENT : 1 PRODUCT OVERVIEW 1.1

More information

AUR300C. Advanced Ultraviolet Burner Controller

AUR300C. Advanced Ultraviolet Burner Controller No. CP-SS-1807E AUR300C Advanced Ultraviolet Burner Controller Overview The AUR300C is a burner controller with a dynamic selfchecking function and is used in combination with the AUD300C or AUD500C Advanced

More information

Laser Collimated Beam Sensor

Laser Collimated Beam Sensor SERIES Laser Collimated Beam Sensor Class 1 Laser Beam Sensor Safe for Your Eyes Marked Conforming to EMC Directive (Excluding LA-C1) Safe Laser Beam This laser collimated beam sensor conforms to the Class

More information

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector. Color Mark Sensor Detects laminated or light-dispersing objects in stable operation without being influenced by mirror reflection. Double indication of the detection level and threshold level allows easy

More information

INSTRUCTIONS AK-CC 250A

INSTRUCTIONS AK-CC 250A INSTRUCTIONS AK-CC 250A t amb = 0 - +55 C 230 V a.c. 50/60 Hz 2.5 VA 10 V < U < 256 V DO1. Refrigeration * DO2. Defrost * DO3. Fan or refrigeration 2 * Coordinated defrost CE (250 V a.c.) 8 (6) A 8 (6)

More information

Equipment Required. WaveRunner Zi series Oscilloscope 10:1 High impedance passive probe. 3. Turn off channel 2.

Equipment Required. WaveRunner Zi series Oscilloscope 10:1 High impedance passive probe. 3. Turn off channel 2. FFT Analysis TEN MINUTE TUTORIAL February 27, 2012 Summary Fast Fourier Transform analysis is common on most digital oscilloscopes. It is used to view signals in the frequency as well as the time domain.

More information