ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

Size: px
Start display at page:

Download "ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION"

Transcription

1 - 3 5 kg/cm C AS SE THEMOSTATIC H COMPLETE WATE TEMPEATUE CONTOL STATION ECO-MIX Submittal Data Sheet S-5Z-LF August, MEGATON LEAD FEE MODEL NB-LF HOT & COLD INLETS MIXED OUTLET ¼ ETUN PIPING. to GPM(3.7 to 5 l/min) Valve assembly is ASSE 7 Certified Valve assembly is certified to meet Low-Lead requirements of wetted surface area containing less than.5% lead by weight. All other fittings and components, the sum total of which comprise the wetted surface of this product, contain less than one quarter of one percent of lead by weight. See page for Specification detail See page 3 for Drawing detail See page for Flow capacity chart! WANING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer. For more information, go to See page 5 for Options Engineer's Approval Job # Arch/Eng. Contractor Product is non-cancellable and non-returnable from date from order with factory. Signed submittal required with purchase order. Note: The models shown represent Leonard Products which are believed to be equivalent in type and function to items specified. Leonard Valve Company is not responsible for errors or omissions due to differences in interpretations of information provided. Leonard Valve Company Printed in USA 3 Elmwood Avenue, Cranston, I 9 USA Phone:.. Fax: info@leonardvalve.com Web Site:

2 EQUIED INFOMATION WHEN ODEING Circulator requirements must be specified by the Engineer, lines and are EQUIED, line 3 is optional. Circulated flow required, (not mixing valve flow). Head required without Megatron Assembly 3. Standard pump is TACO 3, if another manufacturer is preferred please specify, but note that ANY change from standard pump will result in a PICE INCEASE MEGATON MODEL NB-LF MEGATON MODEL NB-LF Complete Water Temperature Control Station (. - GPM, 3.7 to 5 l/min) to include: Wetted surface area of this product contains less than one quarter of one percent (.5%) of lead by weight Lead Free construction, to comply with LEAD FEE requirements bottom inlet connections (copper tube) top outlet connection (copper tube) ¼ return line size with piping method #5 Large thermostatic water mixing valve with DUA-trol solid bimetal thermostat (with Extended 7 Year Limited Warranty) directly linked to hot and cold valve porting, adjustable high temperature limit stop set for F (9 C)*, color-coded dial: C-H, locking temperature regulator, inlet angle strainer checkstops Full port ball valve, pressure gauge on mixed water outlet piping of large mixing valve. Small thermostatic water mixing valve with DUA-trol solid bimetal thermostat (with Extended 7 Year Limited Warranty) directly linked to hot and cold valve porting, adjustable high temperature limit stop set for F(9 C)*, color-coded dial: Cold-Hot, integral checkstops on inlets. Full port ball valve on outlet of small mixing valve Dial thermometer (range: to F,-to C) and pressure gauge on mixed water outlet of the system. Outlet Test Connection with ball valve and ¾ hose connection with cap Full port ball valve mounted downstream of test connection on mixed water outlet of the system Inlet piping manifold with full port ball valves and dial thermometers ( to F, -7 to C on hot supply, to F,-to C on cold supply) on hot and cold supply inlets eturn piping, ¼, with aquastat, circulator, dial thermometer ( to F,-to C), balancing valve (with positive shutoff) to balance system, and check valve Aquastat with temperature differential of 5 to 3 F(3to7 C) GFCI* switch. The GFCI switch will be used to turn the circulator on or off for setup. *Ground Fault Interrupter Bypass piping, ¼, with check valve and isolation ball valve Maximum operating pressure: 5 PSIG (KPA) System mounted on strut, galvanized. Strut shall be assembled with three hole flat angle plate on corners, four hole tee plates or two hole flat plate connectors on all other support pieces using 3/ grip lock nuts and 3/ x hex head cap screws, washers and lock washers. Factory pre-assembled and tested as a complete system All electrical connections to be completed by Electrical Contractor

3 - 3 LEO NAD 5 kg/cm ASSE THEMOSTATIC LEO NAD 5 - MEGATON MODEL NB-LF " MIXED OUTLET " 9 7 -/" ETUN FOM BUILDING " 3 C H 3 " " HOT " COLD 5 5 -/" ETUN TO HOT WATE SOUCE Dimensions may vary with the addition of options see page #5 LEGEND. Full port ball valve. Large TM mixing valve 3. Small TM mixing valve. Test connection 5. Balancing Valve. Dial thermometer 7. Pressure gauge. Circulator-As specified by Engineer 9. Aquastat. Circulator power switch. Flapper check. Galvanized Strut 3. Tee bracket. Corner Bracket 5. Tee Drain 3

4 - 3 5 kg/cm ps i LEONA D C ASSE THEMOSTATIC H LEO N AD 5 - MEGATON MODEL NB-LF (. TO GPM) Flow Capacity MINIMUM FLOW (GPM) (l/min).3 5 SYSTEM PESSUE DOP (PSIG) PSI BA (3.7) GPM l/min NOTE: Flowrates will vary depending on existing field conditions. Leonard Valve Company always recommends using CASPAK sizing software for proper valve sizing and model number applications. Note: The High Low model must be selected based upon the following: Maximum system demand for mixed water System pressure drop* Designer s estimated minimum mixed water flow requirement *System pressure drop= the pressure available at the inlet of the mixing valve unit minus the pressure required to operate the farthest fixture, i, e,. Shower valves, in the building. EQUIED PIPING METHOD #5 DOMESTIC TEMPEED WATE HIGH TEMP. WATE BALANCING VALVE HOT WATE SOUCE HEAT TAP COLD SUPPLY EXTENDED THEMOSTAT WAANTY Call the factory at --- for details on Leonard's exclusive Extended Limited Warranty for High Low System Thermostats. Note! Specifications are subject to change without notice.!!!!

5 LE ONA D kg/cm LE O NA D kg/cm LEONA D kg / cm LE ONA D LEON AD OPTIONS LC Megatron furnished without a circulator. FM Megatron with 3 legs, 3 ½ feet and 5 degree braces front and back for mounting to floor in center of room. FS Megatron with legs to floor to support the unit without hangers. CAB Megatron with SS cabinet around mixing valve PUMPS edundant recirculation pump PUMPS H High temperature loop recirculation pump HBP High temperature by-pass flush with locking ball valve OPTIONS * OPTIONS (shown on next page) * PIPING OPTIONS * LC Less circulator FM Floor mount FS Free standing CAB Cabinet around mixing valve PUMP - edundant recirculator pump PUMP H - High temperature loop recirculator pump HBP- High temperature by-pass flush AL Audio Visual Alarm DU emote Display Unit LMS--P Leonard Monitoring system LMS--P-BMS Leonard Monitoring system with module to connect to building management P ½ - ½ eturn line size (M5) P - eturn line size (M5) * Any option chosen will alter pricing Leonard Valve Company Printed in USA 5 3 Elmwood Avenue, Cranston, I 9 USA Phone:.. Fax: info@leonardvalve.com WEB:

6 OPTION AL: Leonard Single Probe Digital Temperature Alarm Primary Alarm Box includes: Single Point Temperature Probe - ange: -ºF to ºF esolution: ºF User adjustable high & low set points and initial alarm delay period Audible & visual alarms emote alarm contacts (SPDT) with adjustable relay delay period Min./Max. temperature values AL option replaces analog outlet dial thermometer with a single digital display OPTION DU: Leonard emote Display Unit emote Alarm Delay Option Includes: Activation by Primary Alarm s (pictured above) remote alarm contacts Alarm Delay Module with yellow, red, green LED indicators ecommended maximum distance from controller to DU is 5 OPTION LMS--P: Leonard Point Digital Monitoring System with Alarm Unit includes: Four () Temperature Probes - ange: -ºF to ºF esolution: ºF Audio & visual alarms User adjustable high & low temperature alarm set points Alarm delay period to prevent nuisance alarms emote alarm contacts (SPDT) with adjustable relay period / Ethernet Connection Web Server Interface for Setup & Commissioning Unit can send an transmission of alarms for up to contacts Unit can send an report daily with temperatures readings over the previous day LMS--P option replaces analog dial thermometers with a single digital display for all temperatures, incoming hot, incoming cold, outlet and return OPTION LMS--P-BMS: Leonard Point Digital Monitoring System with Alarm & Enhanced Protocol Communication Interface Module Primary Alarm Box includes: Four () Temperature Probes - ange: -ºF to ºF esolution: ºF User adjustable high & low set points and initial alarm delay period Audio & visual alarms emote alarm contacts (SPDT) with adjustable relay period ProtoNode Accessory Box includes: Interface Module to connect LMS--P-BMS to Building Management System (-BMS) Network, Complete Protocol Package Supported protocols include BACnet MS/TP, BACnet IP, Modbus TU, Modbus TCP/IP, SNMP, JC N, available simply by selecting the proper DIP switches Cat 5 Ethernet Cable not included LMS--P-BMS option replaces analog dial thermometers with a single digital display for all temperatures, incoming hot, incoming cold, outlet and return Leonard Valve Company Printed in USA 3 Elmwood Avenue, Cranston, I 9 USA Phone:.. Fax: info@leonardvalve.com Web Site:

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION - 3 5 kg/cm ASSE 7 - CO. 3 5 THEMOSTATIC TYPE TM US. Patent 77 & 3,,95 3.5,7.I. - 3 5-3 5 COMPLETE WATE TEMPEATUE CONTOL STATION ECO-MIX Submittal Data Sheet S-5Z-LF August, MEGATON LEAD FEE MODEL 3NB-LF

More information

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION - 5 kg/cm 7 7-5 - 5-5 Submittal Data Sheet S-5Z-LF April, COMPLETE WATE TEMPEATUE CONTOL STATION ECO-MIX MEGATON LEAD FEE MODEL NB-LF ¾ HOT & COLD INLETS MIXED OUTLET ¾ ETUN PIPING. to GPM(.7 to 7 l/min)

More information

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION - 3 5 ps i kg/cm ASSE 7 VAL VE - CO. 3 5 THEMOSTATIC TYPE TM US. Patent 77 & 3,,95 3.5,7.I. - 3 5-3 5 Submittal Data Sheet S-533Z-LF April, COMPLETE WATE TEMPEATUE CONTOL STATION ECO-MIX MEGATON LEAD FEE

More information

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION 1-1 3 1 5 1 kg/cm 11 1 1 1 1 1 1-1 3 1 5 1 1-1 3 1 5 1 1-1 3 5 1 COMPLETE WATE TEMPEATUE CONTOL STATION ECO-MIX Valve is ASSE 117 Certified Submittal S-11-1-LF August, 1 MEGATON LEAD FEE MODEL XLLF 1 HOT

More information

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION MEGATRON MODEL 10NB-LF 4 HOT & COLD INLETS 4 MIXED OUTLET 2 RETURN PIPING

ECO-MIX COMPLETE WATER TEMPERATURE CONTROL STATION MEGATRON MODEL 10NB-LF 4 HOT & COLD INLETS 4 MIXED OUTLET 2 RETURN PIPING 4 4 5-4 3 8 4 4 5-3 8 4 TERMOSTATI 4 3 4 5-8 4 TERMO STATI TERMOSTATI 4 4 5-3 8 4 4-3 8 4 4 5 OMPLETE WATER TEMPERATURE ONTROL STATION EO-MIX Valve assemblies are ASSE 7 listed Submittal S-596Z-LF August,

More information

Submittal S-NV-150-LF-M November, 2018 MEGATRON MODEL NV-150-LF DIGITAL TEMPERATURE CONTROL STATION

Submittal S-NV-150-LF-M November, 2018 MEGATRON MODEL NV-150-LF DIGITAL TEMPERATURE CONTROL STATION ! APPROXIMATE DIMENSIONS A = 3-3 B = 3-10-1/2 C = 4 D = 9-1/2 *Image not to scale* WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer.

More information

Submittal S-NV-200-LF-M DIGITAL TEMPERATURE CONTROL STATION. Valve assembly is ASSE 1017 Certified. Valve assembly is cupc Certified

Submittal S-NV-200-LF-M DIGITAL TEMPERATURE CONTROL STATION. Valve assembly is ASSE 1017 Certified. Valve assembly is cupc Certified ! APPROXIMATE DIMENSIONS A = 3-11 B = 3-9 C = 4-1/2 D = 1-1 *Image not to scale* WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer.

More information

COMPLETE WATER TEMPERATURE CONTROL SYSTEM

COMPLETE WATER TEMPERATURE CONTROL SYSTEM OMPLETE WATE TEMPEATUE ONTOL SYSTEM MEGATON omplete Water Temperature ontrol Systems regulate water temperature for building hot water systems and other commercial, institutional and industrial applications.

More information

NEW GENERATION HIGH LOW SYSTEMS

NEW GENERATION HIGH LOW SYSTEMS NEW GENEATION HIGH LOW SYSTEMS NEW GENEATION TM-52-DT HIGH LOW SYSTEMS control water temperature for domestic hot water systems, shower rooms and other commercial, institutional and industrial applications

More information

MEGATRON MODEL 2NB-LF, 3NB-LF, 4NB-LF, 5NB-LF NEXT GENERATION MANIFOLD SYSTEMS TM-520B-LF, 820B-LF, 920B-LF, 1520B-LF

MEGATRON MODEL 2NB-LF, 3NB-LF, 4NB-LF, 5NB-LF NEXT GENERATION MANIFOLD SYSTEMS TM-520B-LF, 820B-LF, 920B-LF, 1520B-LF 6 1-1 3 8 5 6 1 6 2 1 4 1 8 6 8 kg/cm2 11 psi 1 16 1 1 1 6 1 ASSE 117 VAL VE -1 CO. 3 6 8 5 1 THEMOSTATIC T YPE TM AN STON 1 1.I. U.S.A. 6 1-1 6 3 8 1 5 1 1 6 1-1 6 3 8 5 1 1 1 H C Bulletin M-115Z August,

More information

WATER TEMPERATURE CONTROL SYSTEMS

WATER TEMPERATURE CONTROL SYSTEMS Mixing Safety & Performance for Over 100 Years WATER TEMPERATURE CONTROL SYSTEMS TM-2020B-LF-DT TM-2020B-2PS-LF MEGATRON 6NB-LF ASSE 1017 LOW LEAD CERTIFIED Made in the USA with Domestic and Imported Parts

More information

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed 4 2 AS SE 1 17 6 8 2 3 1 LEONAD 4 5-1 6 C F 14 1 12 4 2 1 17 6 8 2 3 1 LEONAD 4 5-1 6 C F 14 1 12 BULLETIN G-11F February 29 INSTALLATION ADJUSTMENT SEVICE HIGH-LOW MANIFOLD SYSTEMS TM-42A Valve assemblies

More information

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-420A Valve assemblies are ASSE 1017 listed 4 AS SE 1 17 6 1-1 3 LEONAD C F 6 8 14 4 5 1 1 4 1 17 6 1-1 F 3 LEONAD C 6 8 14 4 5 1 1 INSTALLATION ADJUSTMENT SEVICE HIGH-LOW MANIFOLD SYSTEMS TM-4A Valve assemblies are 117 listed Valve assemblies are

More information

MEGATRON MODEL 2N, 3N, 4N, 5N HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF, TM-820-LF, TM-920-LF, TM-1520A-LF

MEGATRON MODEL 2N, 3N, 4N, 5N HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF, TM-820-LF, TM-920-LF, TM-1520A-LF 5-1 8 1 1 2 4 8 6 8 kg/cm 2 11 psi 1 1 1 LEO NAD 17 VAL VE - C O. THEMOSTATIC PE TM 8 5 1 CAN STON 1.I. U.S.A. - 8 1 5 1-8 5 1 1 H C Bulletin M-11Z January 14 MEGATON MODEL 2N, 3N, 4N, 5N HIGH-LOW MANIFOLD

More information

30 R -10 C F H C INSTALLATION. Maximum Operating Pressure 125PSI (860 KPA) for Hot and Cold Water. CAUTION

30 R -10 C F H C INSTALLATION. Maximum Operating Pressure 125PSI (860 KPA) for Hot and Cold Water. CAUTION ASSE 117 1-1 2 6 3 4 5 4 1-1 2 6 3 4 5 BULLETIN G-26-34 January 216 INSTALLATION ADJUSTMENT SEVICE TYPE TM-26-F-DT-34, TM-26-LF-F-DT-34 IMPOTANT! Provide valve serial number (stamped on cover of valve)

More information

MEGATRON MODEL TA, TA-LF

MEGATRON MODEL TA, TA-LF 6 1-1 2 LEONAD 6 3 8 6 C H LEONAD 116 LEONAD VALVE CO. CANSTON I 291 8 2 3 1 LEONAD -1 6 MODEL 21 Water Mixer 117 1 6-1 2 3 LEONAD 6 8 6 8 2 3 1 LEONAD -1 6 MEGATON MODEL TA, TA-LF Bulletin G-1L August,

More information

INSTALLATION ADJUSTMENT SERVICE

INSTALLATION ADJUSTMENT SERVICE Bulletin XL-670 July 201 INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE MODEL XL-670-LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!! ECO-MIX

More information

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE Bulletin 82 August, 208 INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES, -LF,, -LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!!!

More information

MODEL TA. TA-SB 117.5mm mm HOT INLET. TA mm mm mm mm

MODEL TA. TA-SB 117.5mm mm HOT INLET. TA mm mm mm mm WATER MIXER WATER MIXER TRERMOSTATIC WATER MIXER TRERMOSTATIC C TRERMOS TA TIC WA TER MIXER MODEL TA Bulletin P-7A-4 May 2011 (NEW STYLE) THERMOSTATIC WATER MIXING VALVES INSTALLATION SETUP AND OPERATING

More information

CLASSIC HIGH LOW MANIFOLD SYSTEMS

CLASSIC HIGH LOW MANIFOLD SYSTEMS LASSI HIGH LOW MANIOLD SYSTEMS LEONARD LASSI HIGH LOW MANIOLD SYSTEMS control water temperature for domestic hot water systems, shower rooms and other commercial, institutional and industrial applications

More information

INSTALLATION ADJUSTMENT SERVICE

INSTALLATION ADJUSTMENT SERVICE ASSE 1017 INSTALLATION ADJUSTMENT SERVICE TYPE TM-26, TM-26-LF BULLETIN G-26 January 2014 IMPORTANT! Provide valve serial number (stamped on cover of valve) when ordering parts!! Valve manufactured after

More information

MEGATRON MODEL 2, 3, 4, and 5

MEGATRON MODEL 2, 3, 4, and 5 MEGATRON MODEL 2, 3, 4, and 5 BULLETIN M-1020A 2/02 INSTALLATION ADJUSTMENT SERVICE COMPLETE WATER TEMPERATURE CONTROL STATION DOMESTIC OUTLET TEST/SETUP CONNETION RETURN LINE FROM BUILDING RETURN LINE

More information

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20, TM-20-LF (As furnished with models TM-554, TM-356, TM-356-W/HA)

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20, TM-20-LF (As furnished with models TM-554, TM-356, TM-356-W/HA) ASSE 1017 INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20, TM-20-LF (As furnished with models TM-554, TM-356, TM-356-W/HA) BULLETIN P-15A January, 2014 IMPORTANT! Provide valve serial number when ordering

More information

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82 Bulletin XL-38 March 00 INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-3, XL-8 IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!!

More information

OUTLET HOT INLET COLD INLET INSTALLATION

OUTLET HOT INLET COLD INLET INSTALLATION Bulletin G-29 December 2007 INSTALLATION ADJUSTMENT SERVICE TYPE TM-28 IMPORTANT! Provide valve serial number (stamped on cover of valve) when ordering parts!! Valve manufactured after July 2007 starting

More information

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982 Bulletin LV-98 March 010 INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES & LV-98 IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!! ASSE 1017

More information

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20* (As furnished with models TM-554, TM-356, TM-356-W/HA Valve is ASSE 1017 listed

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20* (As furnished with models TM-554, TM-356, TM-356-W/HA Valve is ASSE 1017 listed ASSE 1017 INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20* (As furnished with models TM-554, TM-356, TM-356-W/HA Valve is ASSE 1017 listed *Valve is CUPC listed IMPORTANT! Provide valve serial number

More information

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE Bulletin GLV-98 Old Rev. LV-98 February 1 INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES, LV981-LF &, -LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering

More information

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM TM-500, TM-550

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM TM-500, TM-550 C BULLETIN G-6A January 2012 INSTALLATION SETUP AND OPERATING INSTRUCTIONS WATER SYSTEM TM-500, TM-550 IMPORTANT! Provide valve serial number (located on valve body) when ordering parts!! Starting with

More information

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE Bulletin XL-150 February 2015 INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-150, XL-150-LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering

More information

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE . Bulletin XL-200 INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES XL-200, XL-200-LF, XL-200-SW, XL-200-SW-LF IMPORTANT! Provide valve serial number, (located on valve cover) when

More information

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE Bulletin GLV-101 Old Rev. LV-101 INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-983, LV-983-LF & LV-984, LV-984 -LF IMPORTANT! Provide valve serial number, (located on valve

More information

MODEL 270-LF ECO-MIX THERMOSTATIC MIXING LEAD FREE THERMOSTATIC POINT OF USE MIXING VALVE. Submittal Data Sheet S-827-LF February 2013

MODEL 270-LF ECO-MIX THERMOSTATIC MIXING LEAD FREE THERMOSTATIC POINT OF USE MIXING VALVE. Submittal Data Sheet S-827-LF February 2013 TERMOSTATI MIXING VALVE 5-1/2" 140mm EO-MIX Submittal Data Sheet S-827-LF February 2013 MODEL 270-LF LEAD FREE TERMOSTATI POINT OF USE MIXING VALVE MODEL ½ inlets, ½ outlet, (MIPS connections) MATERIALS:

More information

TA-300, TA-300-LF, TA-350, TA-350-LF

TA-300, TA-300-LF, TA-350, TA-350-LF Bulletin G-5 INSTALLATION SETUP AND OPERATING INSTRUCTIONS EMERGENCY MIXING VALVE SYSTEM TA-300, TA-300-LF, TA-350, TA-350-LF IMPORTANT! Provide valve serial number (located on valve body) when ordering

More information

INSTALLATION ADJUSTMENT SERVICE NEXT-GENERATION MANIFOLD SYSTEMS TM-520B-LF, TM-820B-LF, TM-920B-LF, TM-1520B-LF

INSTALLATION ADJUSTMENT SERVICE NEXT-GENERATION MANIFOLD SYSTEMS TM-520B-LF, TM-820B-LF, TM-920B-LF, TM-1520B-LF 2 6 4 1 O. RANSTON RI USA TYP TM U S. Pat en ts 2. 97, 3, 6 1,1 95 3.15 2,76 8 2 3 R 4 5-1 6 F 14 1 12 Bulletin G-12 August, 218 INSTALLATION ADJUSTMENT SERVIE NEXT-GENERATION MANIFOLD SYSTEMS TM-52B-,

More information

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM * TM-500A, TM-550A

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM * TM-500A, TM-550A C ASSE 1017 BULLETIN G-6B March 2009 INSTALLATION SETUP AND OPERATING INSTRUCTIONS WATER SYSTEM * TM-500A, TM-550A IMPORTANT! Provide valve serial number (located on valve body) when ordering parts!! *ASSE

More information

TMV45 & TMV80 Standard Thermostatic Mixing Valves

TMV45 & TMV80 Standard Thermostatic Mixing Valves Reliable liquid-filled thermostat Integral strainer checkstops on inlets Adjustable set point within temperature range Accurate temperature control Positive shutoff of hot supply when cold supply is lost

More information

HL45, HL80 Thermostatic High-Low Valves

HL45, HL80 Thermostatic High-Low Valves Lead-Free Brass Design Reliable Liquid-Filled Thermostat with 10 year warranty Integral Strainer Checkstops on Inlets Adjustable Set Point within Temperature Range Accurate Temperature Control to within

More information

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE Bulletin GLV-99 July, 01 INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE LV-981A, LV-981A-LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!! INSTALLATION

More information

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE Bulletin GLV-0 September 01 INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE LV-0, LV-0-LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!! INSTALLATION

More information

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE Bulletin GLV- January 014 INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE LV-, LV--LF IMPORTANT! Provide valve serial number, (located on valve cover) when ordering parts!! INSTALLATION

More information

DOMESTIC OUTLET. kg/cm 2 11 psi LEONARD LEONARD -10 C F LEONARD R THERMOSTATIC LEONARD LEONARD C F C F 60 COLD INLET HOT INLET

DOMESTIC OUTLET. kg/cm 2 11 psi LEONARD LEONARD -10 C F LEONARD R THERMOSTATIC LEONARD LEONARD C F C F 60 COLD INLET HOT INLET 4 1-1 3 R 8 14 4 5 4 1 2 1 4 8 6 kg/cm 2 11 psi 8 1 1 1 14 1 4 ASSE 117 1-1 3 R 8 14 4 5 THERMOSTATI H 1 1 4 1-1 3 R 8 14 4 5 1 1 4 1-1 3 R 8 14 4 5 1 1 M-122Z September 1 MEGATRON MODEL 6N INSTALLATION

More information

LMS-188-4P-BMS 4 POINT DIGITAL MONITOR/ALARM WITH PROTOCOL CONVERTER OPERATING INSTRUCTIONS

LMS-188-4P-BMS 4 POINT DIGITAL MONITOR/ALARM WITH PROTOCOL CONVERTER OPERATING INSTRUCTIONS G LMS 188 4P BMS August, 2018 LMS-188-4P-BMS 4 POINT DIGITAL MONITOR/ALARM WITH PROTOCOL CONVERTER OPERATING INSTRUCTIONS! WARNING: This product can expose you to chemicals including lead, which is known

More information

INSTALLATION ADJUSTMENT SERVICE TM-1520A-DT, TM-2020A-DT PARALLEL SYSTEMS

INSTALLATION ADJUSTMENT SERVICE TM-1520A-DT, TM-2020A-DT PARALLEL SYSTEMS ASSE 1 17 TERMOSTATI 4 1-1 F 3 R 8 14 4 5 1 1 ASSE 1 17 TERMOSTATI VALVE O. RANSTON RI USA TYP TM US. Patents 2.97, 3,61,195 3.152,7 4 1-1 F 3 R 8 5 14 4 1 1 VALVE O. RANSTON RI USA TYP TM US. Patents

More information

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF TM-820-LF, TM-920-LF, TM-1520A-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF TM-820-LF, TM-920-LF, TM-1520A-LF LEO ASSE R US. Patent 770 & 3,061,195 3.152,760 O. PE TM RAN STON R.I. Bulletin G11D April 2014 INSTALLATION ADJUSTMENT SERVIE HIGH-LOW MANIFOLD SYSTEMS TM-520, TM-820, TM-920, TM-1520A TM-520-LF TM-820-LF,

More information

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet Cold Water Thermometer Hot Water Inline Check Redundant Thermostatic Mixing Valve Angle Checkstops

More information

INSTALLATION ADJUSTMENT SERVICE MEGATRON MODEL 8N-LF. Valve assemblies are ASSE 1017 listed

INSTALLATION ADJUSTMENT SERVICE MEGATRON MODEL 8N-LF. Valve assemblies are ASSE 1017 listed 4 6 2 8 6 4 8 kg/cm 2 11 psi 1 1 6 1 1 4 1 4 6 4 1-1 6 3 8 14 6 1-1 4 5 1 1 6 3 8 14 4 5 1 1 TERMOSTATI 4 6 1-1 6 3 8 14 4 5 1 1 TERMOSTATI 4 6 1-1 6 3 8 14 4 5 1 1 4 6 1-1 LE ON ARD 6 3 8 14 4 5 1 1 EO-MIX

More information

EZ Plate Instantaneous

EZ Plate Instantaneous EZ Plate Instantaneous Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water PVI.com Packaged Instantaneous Domestic Hot Water EZ Plate Instantaneous is a factory-packaged, skid-mounted

More information

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer 1/2" OD Copper Tube Inlets Hot Water Inlet Cold Water Inlet G3600LF Installation 1. Install valve in

More information

DigiTemp. Digital Water Tempering System. PVI.com

DigiTemp. Digital Water Tempering System. PVI.com DigiTemp Digital Water Tempering System PVI.com DigiTemp Digital Water Tempering System DigiTemp is a domestic hot water main mixing station for commercial and institutional facilities that intelligently

More information

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet. Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet Angle Checkstop Angle Checkstop Hot Water Inlet G3700LF Cold Water Inlet Installation 1.

More information

Mixing Safety and Performance

Mixing Safety and Performance Mixing Safety and Performance For For Over Over 100 100 Years Years About Leonard Valve Company Mixing Safety and Performance At Leonard Valve Company, our passion is to provide safe hot water for our

More information

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Hot Water Tempered Water Outlet Cold Water Tempered Water Outlet Redundant Thermostatic Mixing Valve Hot Water

More information

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20 (As furnished with models TM-554, TM-356, TM-356-W/HA, TM PRV, 8015, 12520, 15020)

INSTALLATION ADJUSTMENT SERVICE TYPE TM-15, TM-20 (As furnished with models TM-554, TM-356, TM-356-W/HA, TM PRV, 8015, 12520, 15020) OT BULLETIN P-15 June, 2006 INSTALLATION ADJUSTMENT SERVIE TYPE TM-15, TM-20 (As furnished with models TM-554, TM-356, TM-356-W/HA, TM-186-5015-PRV, 8015, 12520, 15020) IMPORTANT! Provide valve serial

More information

Automatic Temperature Controller (ATC)

Automatic Temperature Controller (ATC) NEW FROM APOLLO...THE FIRST MULTIPLE-FIXTURE HI-LO MIXING VALVE THAT MEETS ASSE 1017 AND THE NEW ASSE 1069 STANDARD Only Apollo offers fast delivery on the first water temperature mixing assembly to meet

More information

Wall Mounted Shower Systems

Wall Mounted Shower Systems Wall Mounted Shower Systems Leonard Surfashower Wall-Mounted Shower Systems Offered in thermostatic or pressure actuated models with standard or ADA compliant shower head/hand shower configurations. Wall

More information

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF 1 ASSE 117 3-1 F 8 5 1 TERMOSTATI 1 1 ASSE 117 1-1 F 8 3 5 1 TERMOSTATI 1 1 Bulletin G-11E August, 18 INSTALLATION ADJUSTMENT SERVIE IG-LOW MANIFOLD TM-B, TM-B-LF IMPORTANT! Provide serial numbers for

More information

HOT INLET COLD INLET INSTALLATION

HOT INLET COLD INLET INSTALLATION EMERGENY VALVE F EMERGENY VALVE Bulletin G-4 INSTALLATION SETUP AND OPERATING INSTRUTIONS WATER SYSTEMS TYPE TM-600, TM-600-LF, TM-650, TM-800, TM-800-LF, TM-850, TM-850-LF TM-5100, TM-5100-LF, TM-5125,

More information

water source / fan coils

water source / fan coils MANUAL BALL ALE W/MEMORY STOP (BMS) An adjustable stop position lever to limit travel of the On/Off handle. This allows the ball valve to be closed, and returned to the balance setting position without

More information

INSTALLATION ADJUSTMENT SERVICE TM-1520A-2P, TM-1520A-2P-LF TM-2020B-2P, TM2020B-2P-LF PARALLEL SYSTEMS

INSTALLATION ADJUSTMENT SERVICE TM-1520A-2P, TM-1520A-2P-LF TM-2020B-2P, TM2020B-2P-LF PARALLEL SYSTEMS OT ASSE 117 4 2 1-1 2 3 R F 8 14 4 5 1 12 ASSE 117 VALVE O. RANSTON RI USA AS SE 117 TYP TM US. Patents 2.97, 3,61,195 3.152,7 4 2 1-1 2 F 3 R 8 5 14 4 1 12 VALVE O. RANSTON RI USA A SSE 117 TYP TM U S.

More information

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEMS TYPE *TM-600, TM-650, *TM-800, *TM-850, TM-5100, TM-5125

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEMS TYPE *TM-600, TM-650, *TM-800, *TM-850, TM-5100, TM-5125 EMERGENY VALVE F EMERGENY VALVE INSTALLATION SETUP AND OPERATING INSTRUTIONS WATER SYSTEMS TYPE *TM-600, TM-650, *TM-800, *TM-850, TM-5100, TM-5125 IMPORTANT! Provide valve serial number, (stamped on valve

More information

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE TM-200 (NEW STYLE) TMS-200 (VALVE ONLY)

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE TM-200 (NEW STYLE) TMS-200 (VALVE ONLY) Bulletin G-2D-1 September 2008 INSTALLATION ADJUSTMENT SERVIE TERMOSTATI WATER MIXING VALVE TM-200 (NEW STYLE) TMS-200 (VALVE ONLY) IMPORTANT! This Bulletin covers valves built after June 2001, starting

More information

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water

Packaged Instantaneous Domestic Hot Water Generator Energy Source: Boiler Water Packaged Instantaneous Domestic Hot Water Generator Energy Source: Shown with optional boiler water valve and electronic feed-forward control. Operates with low boiler water supply and return temperatures

More information

INSTALLATION ADJUSTMENT SERVICE 2P TM-2020B-2P, TM2020B-2P-LF PARALLEL SYSTEMS

INSTALLATION ADJUSTMENT SERVICE 2P TM-2020B-2P, TM2020B-2P-LF PARALLEL SYSTEMS OT ASSE 117 4 2 1-1 2 3 R F 8 14 4 5 1 12 ASSE 117 VALVE O. RANSTON RI USA AS SE 117 TYP TM US. Patents 2.97, 3,61,195 3.152,7 4 2 1-1 2 F 3 R 8 5 14 4 1 12 VALVE O. RANSTON RI USA ASSE 117 U S. Pate nt

More information

INSTALLATION ADJUSTMENT SERVICE 2PS TM-2020B-2P, TM2020B-2PS-LF PARALLEL SYSTEMS

INSTALLATION ADJUSTMENT SERVICE 2PS TM-2020B-2P, TM2020B-2PS-LF PARALLEL SYSTEMS OT ASSE 117 TERMOSTATI 4 2 1-1 2 3 R F 8 14 4 5 1 12 ASSE 117 TERMOSTATI LF VALVE O. RANSTON RI USA TYP TM LF 4 2 1-1 2 F 3 8 5 14 4 1 12 LF VALVE O. RANSTON RI USA TYP TM LF Bulletin G11N5 March 215 INSTALLATION

More information

BRADLEY CORPORATION DOMESTIC WATER PIPING SPECIALTIES Page 1 of 9

BRADLEY CORPORATION DOMESTIC WATER PIPING SPECIALTIES Page 1 of 9 BRADLEY THERMOSTATIC MIXING VALVES Bradley Corporation, a leader in the manufacture of fixtures and plumbing products, produces four lines of thermostatic mixing valves (TMVs). Bradley Navigator High-Low

More information

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B 2 4 1 11 7 6 8 2 3 4 5-1 6 F 14 TERMOSTATI 1 12 2 ASSE 117 6 4 1 8 2 3 4 5-1 6 F 14 TERMOSTATI 1 12 Bulletin G-11E June 29 INSTALLATION ADJUSTMENT SERVIE IG-LOW MANIFOLD TM-22B Valve assembly is ASSE 117

More information

SS-7600 THERMOSTATIC MODEL INSTALLATION INSTRUCTIONS

SS-7600 THERMOSTATIC MODEL INSTALLATION INSTRUCTIONS LEONARD SS-7600 THERMOSTATIC MODEL ½ top inlets Valve is ASSE 06 Listed INSTALLATION INSTRUCTIONS Bulletin 7600-SS March 06 SHOWER HEAD O'RING (TM-6B) 6 8 0 HOT COLD 7 9. Remove item (), - #/-0 X / long

More information

Installation S

Installation S Installation S59-3080 Thermostatic Mixing Valve with Optional Cabinet S59-3080RE (with Recess-Mounted Enamel Cabinet) S59-3080RS (with Recess-Mounted Stainless Steel Cabinet) S59-3080SE (with Surface-

More information

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF 2 4 1 11 7 8 2 3 4 5-1 F 14 1 12 2 4 1 ASSE 117 2 3 4 5-1 F 8 14 1 12 Bulletin G-11E April 214 INSTALLATION ADJUSTMENT SERVIE IG-LOW MANIFOLD TM-22B, TM-22B-LF IMPORTANT! Provide serial numbers for both

More information

Heat Transfer Packages

Heat Transfer Packages Heat Transfer Packages Heat Transfer Package (HTP Series) Building Heat, Process Heat, Swimming Pool Heater, Cooling Applications and Snow Melt Package (SMP Series) Steam,, High Temperature Hot Water,

More information

INDIRECT FIRED EQUIPMENT INSTALLATION FORM

INDIRECT FIRED EQUIPMENT INSTALLATION FORM INDIRECT FIRED EQUIPMENT INSTALLATION FORM Please complete ONE (1) form for each SITE at which Indirect Fired units are installed and return it to AERCO for warranty validation within 30 days of start-up.

More information

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF

INSTALLATION ADJUSTMENT SERVICE HIGH-LOW MANIFOLD TM-2020B, TM-2020B-LF 2 1 ASSE 117 2 3-1 F 8 5 1 TERMOSTATI 1 12 2 ASSE 117 1 2 3-1 F 8 5 1 TERMOSTATI 1 12 Bulletin G-11E April 217 INSTALLATION ADJUSTMENT SERVIE IG-LOW MANIFOLD TM-22B, TM-22B-LF IMPORTANT! Provide serial

More information

EZT Series Integra Med Touch Area Alarm & Zone Valve Box with EZ Backfeed

EZT Series Integra Med Touch Area Alarm & Zone Valve Box with EZ Backfeed Submittal Data Sheet Features The Powerex Med Touch area alarm zone valve panel digitally displays gas pressure (1 psi increments) and provides alarm conditions as required by the latest edition of NFPA

More information

Installation S

Installation S Installation S59-2025 Thermostatic Mixing Valve (TMV25) with Optional Cabinet S59-2025RE (with Recess-Mounted Enamel Cabinet) S59-2025RS (with Recess-Mounted Stainless Steel Cabinet) S59-2025SE (with Surface-Mounted

More information

Installation S

Installation S Installation S59-3200 Thermostatic Mixing Valve (HL200) with Optional Cabinet S59-3200RE (with Recess-Mounted Enamel Cabinet) S59-3200RS (with Recess-Mounted Stainless Steel Cabinet) S59-3200SE (with Surface-Mounted

More information

WALL MOUNTED SHOWER SYSTEMS

WALL MOUNTED SHOWER SYSTEMS WALL MOUNTED SHOWER SYSTEMS Wall mounted shower systems for schools, institutions, clubs, industrial and shipboard applications. Thermostatic, pressure balanced, or single temperature models Single or

More information

Pressure Steam Humidifiers. Designed to deliver reliable humidity from facility steam boilers. Live Steam

Pressure Steam Humidifiers. Designed to deliver reliable humidity from facility steam boilers. Live Steam Pressure Steam Humidifiers Designed to deliver reliable humidity from facility steam boilers Live Steam Humidifiers designed to deliver reliable humidity from facility steam boilers. People spend 90% of

More information

LEONARD -10 LEONARD VALVE CO. CRANSTON RI USA. TYP TM US. P aten ts 2.970, 3,06 1, , " Maximum Operating Pressure 125PSI (8.6 Bar).

LEONARD -10 LEONARD VALVE CO. CRANSTON RI USA. TYP TM US. P aten ts 2.970, 3,06 1, ,  Maximum Operating Pressure 125PSI (8.6 Bar). 2 0 2 4 6 80 kg/cm psi 2 11 LEO NARD 8 10 1 10 0 1 TERMOSTATI 1 10 0-10 0 R F VALVE O. RANSTON RI USA TYP TM US. P aten ts 2.970, 3,06 1,195 3.152,76 0 30 80 1 50 100 1 Bulletin G18E May 08 INSTALLATION

More information

OUTLET LEONARDH THERMOSTATIC INSTALLATION

OUTLET LEONARDH THERMOSTATIC INSTALLATION Bulletin G-AT June 2012 INSTALLATION ADJUSTMENT SERVIE ALLTERNATIVE TEMPERATURE TERMOSTATI WATER MIXING VALVES TYPE TM-50-AT, 80-AT, 150-AT, 200-AT IMPORTANT! Provide valve serial number, (stamped on cover

More information

SECTION DOMESTIC WATER PIPING SPECIALTIES

SECTION DOMESTIC WATER PIPING SPECIALTIES SECTION 22 11 19 DOMESTIC WATER PIPING SPECIALTIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Semi-Instantaneous Indirect Fired Water Heater

Semi-Instantaneous Indirect Fired Water Heater MODEL BWX Semi-Instantaneous Indirect Fired Water Heater Use Boiler Water Or HTHW To Heat Domestic Water Features Reliable Only high grade materials used in construction to ensure long operating life Hydrastone

More information

ADMS. AERCO Digital Mixing Station. AERCO.com

ADMS. AERCO Digital Mixing Station. AERCO.com ADMS AERCO Digital Mixing Station AERCO.com AERCO Digital Mixing Station The AERCO Digital Mixing Station (ADMS ) is a smart water tempering system that allows temperature controlled distribution of potable

More information

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL The SF-10 Temperature Control () is an efficient boiler operator with a digital LCD display with backlight, a boiler pump output, and an alarm. The

More information

Installation S

Installation S Installation S59-3080 Thermostatic High-Low Mixing Valve (HL80) with Optional Cabinet S59-3080RE (with Recess-Mounted Enamel Cabinet) S59-3080RS (with Recess-Mounted Stainless Steel Cabinet) S59-3080SE

More information

Installation S

Installation S Installation S59-3045 Thermostatic High-Low Mixing Valve (HL45) with Optional Cabinet S59-3045 (Valve Only) S59-3045RE (with Recess-Mounted Enamel Cabinet) S59-3045RS (with Recess-Mounted Stainless Steel

More information

GOLD Plus 30/40/60/80

GOLD Plus 30/40/60/80 PLUS Line Indirect-Fired Water Heaters Series 3 Manual Installation Startup Maintenance Parts PLUS 100/110/119 GOLD Plus 30/40/60/80 Plus 40/60/80 This manual must only be used by a qualified heating installer/service

More information

SEQUENCE OF OPERATIONS

SEQUENCE OF OPERATIONS SEQUENCE OF OPERATIONS DDC CONTROLLER: Controller with integral LCD readout for changing set points and monitoring unit operation. Provided with required sensors and programming. Factory programmed, mounted,

More information

WALL MOUNTED SHOWER SYSTEMS

WALL MOUNTED SHOWER SYSTEMS Mixing Safety & Performance for Over 100 Years WALL MOUNTED SHOWER SYSTEMS Made in the USA with Domestic and Imported Parts 1360 Elmwood Ave., Cranston, RI 02910 TF: 800.222.1208 P: 401.461.1200 F: 401.941.5310

More information

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F 34-200 SERIES HYDRONIC TEMPERING VALVES The Apollo Model TV (34-200 Series) thermostatic mixing valve provides non-asse extension of water heater capacity and hot water temperature control in hydronic

More information

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve VENT APPENDIX A: PIPING SYMBOL LEGEND GENERIC COMPONENTS CALEFFI COMPONENTS circulator circulator w/ ThermoBloc union circulator w/ swing check spring loaded balancing balancing w/ gate check globe s purging

More information

SECTION HUMIDITY CONTROL EQUIPMENT

SECTION HUMIDITY CONTROL EQUIPMENT SECTION 23 84 00 HUMIDITY CONTROL EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Home. One Source For All Your Potable Water Needs

Home. One Source For All Your Potable Water Needs Home One Source For All Your Potable Water Needs AMX300 Thermostatic Mixing Valve Kit Installation that s literally almost no sweat. Kit includes mixing valve, cold water tee, flexible 8" or 11" metal

More information

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series Designed to be used with condensing boilers. Increase the boiler efficiency by allowing condensing boilers

More information

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers. ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page

More information

Med Touch Combination Alarm Conversion Kits

Med Touch Combination Alarm Conversion Kits Submittal Data Sheet Features The Powerex Combination Alarm Panel conversion kits are designed to upgrade or retro-fit existing panels produced by several major brands. The conversion kit replaces all

More information

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s) Furnish and install as shown on AERCO International plans and operation and maintenance manuals, with all applicable codes and authorities having local, state and federal jurisdiction, Benchmark Series

More information

Sequence of operation

Sequence of operation Sequence of operation IPS 4000 secondary variable speed control File No: 90.96 Date: february 21, 2013 Supersedes: new Date: new sequence of operation ips 4000 2 list of abbreviations: adj: Field Adjustable

More information

RQE Series Temperature Controllers

RQE Series Temperature Controllers RQE Series Temperature Controllers For more than 45 years, Thermal Care has manufactured industrial temperature control equipment with the best available component technologies. Our RQE Series mold temperature

More information

Table of Contents. FETCO, and Driven To Pioneer Innovation are trademarks or trade names of Food Equipment Technologies Company.

Table of Contents. FETCO, and Driven To Pioneer Innovation are trademarks or trade names of Food Equipment Technologies Company. www.fetco.com Hot Water Dispensers User s Guide Maritime Versions Rated IP44 Table of Contents Contact Information... 2 Specifications... 2 Dimensions... 3 Installation... 4 Operating Instructions...6

More information