ULTRA HIGH PRESSURE FIRE SUPPRESSION SYSTEMS Product Catalog HMAFIRE.COM FIRE
|
|
- Rudolf Greer
- 5 years ago
- Views:
Transcription
1 HMA FIRE ULTRA HIGH PRESSURE FIRE SUPPRESSION SYSTEMS 2018 Product Catalog HMAFIRE.COM FIRE
2 HMA FIRE ULTRA HIGH PRESSURE FIRE SUPPRESSION SYSTEMS Roots from Air Force Testing The story of HMA Fire starts similar to many successful technologically based businesses in the United States. A problem that the military needed help with, allowing for the opportunity for experienced engineers to design a technology that helped solve the problem for the United States Air Force and NASA. Through a simple contract came a technology that has revolutionized the way fire suppression is accomplished. The original parent company of HMA Fire, Orbital Technologies Corporation, did extensive work with NASA in research and development of rocket propulsion systems. These systems atomized fuel droplets allowing the rockets being blasted into the stratosphere to be utilized more efficiently. NASA and the United States Air Force were having issues extinguishing hydrocarbon fuel fires and running Nacelle (jet engine) fires. The reason? The water droplets were too large to be used efficiently. Through extensive testing and validation with the United States Air Force Fire Research Laboratory and the skilled engineers of Orbital Technologies, the optimum water droplet to be used on running Nacelle fires and hydrocarbon fuel fires was found. These droplets are 1/64th the size of a conventional water droplet, which allowed the water droplets to be drawn into areas of the Nacelle fire that conventional droplets were not able to reach. It soon became obvious that this was a tool for fire departments and other fire suppression industires to use. Photo by Wally Geist St. Germain, WI HMA Fire Today With over a decade in experience and a commitment to innovation, HMA Fire continues to develop and manufacture Ultra High Pressure Fire Suppression Systems that are quickly becoming the industry standard for fire rescue departments around the globe. The day before FDIC International 2017, HMA Fire was acquired by the Robbins Family. With the acquisition came the promise of continued innovation and a renewed mission to provide the best fire suppression equipment in the market with the highest quality, integrity and trust. Partnered with a world class metal fabrication company, HMA Fire is able to produce new and innovative units like never before. New products include our PTO system and our command style unit. From our headquarters in Fall River, Wisconsin, HMA Fire continues to be at the forefront of developing technologies and apparatus that make fighting fires safer and more efficient. Our current focus is on the introduction of suppression systems that integrate with every apparatus and every platform. Through our experienced and dedicated employees, the mission statement of HMA is transparent through to our customers: The protection of life and property is a calling that a select few have. To those courageous, we strive to innovate fire suppression technology that saves life and property by making the job safer, more efficient and more effective.
3 Table of Contents Air Force Testing 4 Modern Fire Environment 6 Ultra High Pressure Overview 7 Hydrus Skid Unit Series 8 Hydrus Integrated Systems 14 Hydrus UTV Series 18 UHP Summits 22 Daytona International Speedway 23
4 OPTIMIZED FLOW RATE FOR TOP PERFORMANCE HMA Fire participated in a series of tests conducted by the U.S. Air Force at Tyndall Air Force Base in Panama City, Florida. The tests studied the effectiveness of different handline flow rates on the extinguishment of hydrocarbon fuel fires. Multiple Systems: Challenging Test Criteria Flow rates at the nozzle from 8 to 150 GPM at pressures from 125 to 1450 psi were tested on a 3,500 square foot pit fire of 380 to 400 gallons of JP-8 fuel. Multi-certified firefighters were used to extinguish each fire. HMA Fire A Clear Winner HMA s Hydrus UHP handline system demonstrated the fastest extinguishing time while using the least suppressant agent. By optimizing our Hydrus system flowing 20 GPM at 1450 psi, HMA provides higher efficiency and safer fighting versus a conventional system. FLOW RATE (GPM) & PRESSURE (PSI) EXTINGUISHMENT TIME % OF FIRE EXTINGUISHED SUPPRESSANT CONSUMED psi 72.5 seconds 80% gallons psi 65.2 seconds 85% gallons psi 58.8 seconds 90% gallons psi 48.3 seconds 100% gallons psi 31.5 seconds 100% gallons psi 68.5 seconds 100% gallons psi seconds 90% gallons psi seconds 80% gallons Photo by Wally Geist St. Germain, WI 4 HMAFIRE.COM
5 Lower Temperatures & Faster Extinguishment For Structural Fires HMA Fire supplied the Vandenberg Air Force Base Fire Department with its Hydrus ultra-high pressure firefighting system for comparative fire testing against the Air Force s standard structural fire equipment. Thermocouples, sensors and infrared cameras were installed in each of the five houses burned to capture data during extinguishment. Safety & Top Performance: The results were striking! HMA s Hydrus, operating at 20 GPM and 1450 psi outperformed a standard 100 GPM / 125 psi system by: Consistently extinguishing fires in 50% less time Using up to 80% less water for significantly less interior damage Restoring visibility within seconds for improved safety Reduced room temperatures faster than the conventional systems. In test after test, HMA Fire s Hydrus reduced ceiling temperatures at or near flash-over to less than 300º F 2.5 minutes faster than conventional equipment valuable minutes to save life and property. Firefighters interviewed after testing reported that the HMA ultra-high pressure systems were easier to handle and resulted in less physical strain than the common 1 3/4 handline used off an Air Force P-19 or standard structural firefighting vehicle. TEMPERATURE (F) AVERAGE CEILING TEMPERATURE IN STRUCTURAL TESTS CONVENTIONAL UHP The HMA Safety Advantage 40 seconds into the fire, HMA s Hydrus had lowered the ceiling temperature 500 º F cooler than a conventional system. UHP extinguished a 16 x 24 room at flash over in 17.3 seconds using only 11.6 gallons of suppressant SECONDS ELAPSED FROM PEAK TEMPERATURE FIRE 5
6 WE DEVELOPED A FIRE SUPPRESSION SYSTEM FOR THE MODERN FIRE ENVIRONMENT Through extensive testing from Underwriter s Laboratory (UL) Firefighter Research Safety Institute, it was found that fires no longer behave like they did 20 years ago. Fires are burning hotter and eight times faster with 233% more chemical signatures in the smoke due to increased use of synthetic materials. HMA Fire s UHP systems are designed for the modern fire environment with firefighters in mind. Our systems allow you get to the fire faster, apply water faster and bring the fire under control. With only 4-5 minutes to make a rescue, every second counts.* *Information regarding the modern fire environment was gathered from UL s Firefighter Research Safety Institute. FIRES ARE BURNING 8X FASTER THAN 20 YEARS AGO. RESPOND QUICKER WITH OUR UHP SYSTEMS. FIRES ARE BURNING HOTTER OUR UHP SYSTEM EXTINGUISHES THAT CHALLENGE. I was an absolute skeptic until I fought a hallway and room fire using Ultra High Pressure. I am convinced this is a better use of tax payer resources at a fraction of the cost of some of our larger apparatus. My goal is to avoid that time it takes for an engine to sit on the front pad filling a cab with six firefighters while a home is burning. A rapid response and quick water delivery, even if its from a back yard of a home fire, will keep emergencies small and manageable. FIRE CHIEF RAY REYNOLDS CITY OF NEVADA, IOWA 6 HMAFIRE.COM
7 SMALLER DROPS. MORE SURFACE AREA. BIGGER IMPACT. Using a piston plunger pump, our UHP system applies 1450 psi to the water, breaking the droplets down to 1/64th the size thereby creating more than 10 times the surface area. These droplets are light enough to be drawn into the fire s flow path, making the water far more effective and efficient. Independent testing has shown UHP is as effective at heat absorption as a conventional 1 3/4 handline flowing at 150 GPM. OPTIMIZED DROPLET SIZE The Laws of Thermodynamics state that only the outer shell of a water droplet can be utilized to absorb heat. This correlates to only 10-20% of a conventional water droplet being used and the remaining water being wasted. Bump up the pressure to 1450 psi, and the water droplet becomes 1/64th the size of conventional water droplets. Optimized water droplets. Optimized heat absorption. REDUCED WATER USAGE Fire usually affects only a small portion of the structure. Water and smoke are responsible for the greatest amount of damage. UHP fire suppression utilizes at least a fifth of the water, leaving significantly less damage. RAPID FIRE ATTACK Fires today are burning 8x faster than they did 20 years ago making a rapid fire attack more important than ever before. Our mobile units allow you to get water to the fire faster, protecting both life and property in a more time efficient manner. INCREASED SURFACE AREA Ultra high pressure fire suppression systems break down the water droplet into 64 smaller droplets. This creates 10x the surface area. More surface area. Bigger impact with the fire. FASTER TEMPERATURE DECREASE Testing has shown that using ultra high pressure fire suppression and proper attack patterns, upper-layer room temperatures can be decreased by more than 1,000 F in seconds, faster than any conventional system. IMPROVED SAFETY Our 3/4 hydraulic hand lines make pushing yourself to the limit a thing of the past. Using our smaller handline will enable you to get to the fire quicker and apply the water quicker, improving the safety of the occupants and your fellow firefighters. FOLLOW US ON FIRE 7
8 Hydrus Skid Unit Series
9 HMA FIRE ULTRA HIGH PRESSURE FIRE SUPPRESSION SYSTEMS RAPID ATTACK FIRE Photo by Wally Geist St. Germain, WI Command Vehicle Deployment Elkhart Chief UHP 20 GPM Nozzle HMA Fire s Ultra High Pressure (UHP) Hydrus Skid Unit Series are designed to be easily installed on any Type 6, Brush Truck, Rapid Response Vehicle, or other appropriately configured Command Vehicle. They are ideal for rapid fire attack on fuel fires, forest and wildlands fires, and structure fires. This self-contained unit incorporates a state-of-the-art UHP fire suppression system powered by a gasoline or diesel engine. In partnership with Elkhart Brass, HMA Fire engineered a nozzle to be utilized on our UHP system. What makes this nozzle different? It is a bale type nozzle, the same that is used on conventional hand lines. We designed this nozzle to make sure it fit the industry standard on fire suppression systems. At HMA Fire, we believe that in today s fire environment, a rapid response and rapid deployment of water is a must. With every second counting to save life and property, pick a system that allows you to compete with that challenge. FOLLOW US ON Each of our Hydrus series UHP system comes with a bale type nozzle allowing for the use of a straight or fog stream. Nozzles are manufactured and rated to the pump gallonage that you desire. Our current offering is 10, 20 and 30 GPM.
10 HMA FIRE Hydrus 20 Skid Unit OPTIONS Water Tank Sizes: 150 and 200 gallons* Dual Hannay Hose Reels Water/ Foam Auto-Fill Valve Water/ Foam Level Indicators Hydrus 10 Run-Dry UHP Piston Plunger Pump Honda 13 HP V-Twin GX series gasoline engine Diesel Drive Option Kit *Other water tank sizes available upon request. SPECIFICATIONS Hydrus 20 Run-Dry UHP Piston Plunger Pump - Ceramic cylinders and seals to improve pump life and lower maintenance. Honda 22 HP V-Twin GX series gasoline engine certified for fire suppression. HMA Venturi foam system: Adjustable from 0.5% to 6% with Class A, Class B or AFFF foam. Industry exclusive auto throttle that activates when the nozzle bale is opened. Manual Override Throttle control Low-level water sensor and auto- system shutdown for low water levels. 5.6 gallon, chassis independent fuel tank Hannay electric rewind hose reel with 200 of ¾ hydraulic hose line. Corrosion resistant high pressure brass and stainless steel fittings. 2 year bumper-to-bumper limited warranty. Length 75 in (1.91 m) Hydrus Hydrus Hydrus in (1.91 m) in (2 m) Width 46 in (1.17 m) Height in (1.05 m) 46 in (1.17 m) in (1.18 m) 46 in (1.17 m) in (1.34 m) Weight (Dry) 1050 lbs. (476 kg) 1100 lbs. (499 kg) 1150 lbs. (522 kg) Weight (Wet) 1885 lbs. (855 kg) 2355 lbs. (1068 kg) 2825 lbs. (1281 kg) Gallons per Minute 20 GPM (75.71 LPM) 20 GPM (75.71 LPM) 20 GPM (75.71 LPM) Pump Pressure 1450 PSI (100 bar) 1450 PSI (100 bar) 1450 PSI (100 bar) Nozzle Pressure 1250 PSI (86 bar) 1250 PSI (86 bar) 1250 PSI (86 bar) Water Tank Size 100 Gallons (379 L) Foam Tank Size 12 Gallons (45 L) 150 Gallons (568 L) 12 Gallons (45 L) 200 Gallons (757 bar) 12 Gallons (45 L) *Height, length, width and weight depend on available apparatus space, chassis requirements and GVWR. All weights are approximate. Schedule a product demonstration today! 10 HMAFIRE.COM
11 HMA FIRE Hydrus Command- NEW Manual Override Throttle control Low-level water sensor and auto- system shutdown for low water levels. 5.6 gallon, chassis independent fuel tank Hannay electric rewind hose reel with 200 of ¾ hydraulic hose line. Corrosion resistant high pressure brass and stainless steel fittings. 2 year bumper-to-bumper limited warranty. SPECIFICATIONS Hydrus 20 Run-Dry UHP Piston Plunger Pump - Ceramic cylinders and seals to improve pump life and lower maintenance. Honda 22 HP V-Twin GX series gasoline engine certified for fire suppression. HMA Venturi foam system: Adjustable from 0.5% to 6% with Class A, Class B or AFFF foam. Aluminum Storage Trays PVC Piping for Tool Storage Poly Tray for 1-3/4 Pre-connect Water and Foam Auto-fill Water and Foam Level Indicator Lights Industry exclusive auto throttle that activates when the nozzle bale is opened. *Designed for a short bed truck. Options available for larger truck beds. Hydrus Command Length 77 in (1.96 m) Width 48 in (1.22 m) Height in (0.97 m) Weight (Dry) 1200 lbs. (544 kg) Weight (Wet) 2,245 lbs. (1018 kg) Gallons per Minute 20 GPM (75.71 LPM) Pump Pressure 1450 PSI (100 bar) 80 Micron Mesh Stainless Steel Filter Water filter included in every Hydrus Series System and designed to filter out water contaminants to extend the longevity of your system. Nozzle Pressure 1250 PSI (86 bar) Water Tank Size 125 Gallons (473 L) Foam Tank Size (Integrated) 12 Gallons (45 L) *Height, length, width and weight depend on available apparatus space, chassis requirements and GVWR. All weights are approximate FIRE 11
12 MODERN PUMP TECHNOLOGY HMA Fire utilizes the most up-to-date pump technology in the market. These modern pumps can withstand temperatures up to 185 F and can run dry for several hours at a time. The pumps have a nickel-plated manifold and valve plugs which provide corrosion-resistant operations and help reduce damage caused by cavitation. 10 GPM Run Dry Pump Our 10 GPM Run Dry Pump is used exclusively on our Hydrus UTV EMS and on select skid units as requested. This pump operates at: 10 GPM 1450 RPM 1500 PSI 20 GPM Run Dry Pump Our 20 GPM Run Dry Pump is our most popular pump and is used for our Hydrus Skid, UTV and Droplet Systems. This pump operates at: 20 GPM 1150 RPM 1500 PSI 30 GPM Run Dry Pump Our 30 GPM Run Dry Pump is exclusively used for our Hydrus Ultimate PTO driven system. This pump operates at: 30 GPM 800 RPM 1500 PSI 12 HMAFIRE.COM
13 ENGINEERED FOR UNMATCHED PERFORMANCE Pressure Relief Valve NIOSH has found that water pressure above 1850 PSI has the ability to cut through skin. We have our pressure relief valve set below that to ensure the safety of you and your fellow firefighters. Thermal Relief Valve Pressure Unloader Thermal relief valve is set to 145 F to protect the pump from hot water.* * Pump is rated to 185 F Our pressure unloader is set to the correct pressure to get you the optimum droplet size for the most heat absorption. Intake Pressure Relief Valve Intake pressure relief valve protects the pump from excess pressure. Honda Engine In order to give you the optimum output from your pump, we obtained an engine that can do just that without over working it. What does this do? By running the engine at less than full RPM, it extends the life of the engine due to less stress being put on the motor. This allows for an extended life of the system. It s no wonder that we have some of our first units from 2006 still in operation today! FIRE 13
14 Hydrus Integrated Systems
15 HMA FIRE ULTRA HIGH PRESSURE FIRE SUPPRESSION SYSTEMS POWERFUL SUPPRESSION APPARATUS FROM ANY Ultra High Pressure Wherever You Want It HMA Fire s Ultra High Pressure (UHP) Hydrus Integrated Systems are designed to be installed on any apparatus. It is ideal for fuel fires, dumpster, car fires, or structure fires. These completely self-contained units are configured to fit your apparatus while incorporating a state-of-the-art UHP fire suppression system. The Integrated Systems can be powered by either a gasoline or diesel engine, or hydraulically driven by an available PTO pump. Most of our Integrated Systems become custom builds to fit the specific requirements of your apparatus. It is our goal to be able to supply first responders with a safe and efficient suppression system that can be installed on any apparatus and any platform. FOLLOW US ON
16 HMA FIRE Hydrus Droplet System OPTIONS Dual Hannay Hose Reels Water/ Foam Auto-Fill Valve Water/ Foam Level Indicators Hydrus 10 Run-Dry UHP Piston Plunger Pump - Honda 13 HP V-Twin GX series gasoline engine Diesel Drive Option Kit SPECIFICATIONS Hydrus 20 Run-Dry UHP Piston Plunger Pump - Ceramic cylinders and seals to improve pump life and lower maintenance. Honda 22 HP V-Twin GX series gasoline engine certified for fire suppression. HMA Venturi foam system: Adjustable from 0.5% to 6% with Class A, Class B or AFFF foam. Industry exclusive auto throttle that activates when the nozzle bale is opened. Manual throttle control Low-level water sensor and auto- system shutdown for low water levels. Hannay electric rewind hose reel with 200 of ¾ hydraulic hose line. Corrosion resistant high pressure brass and stainless steel fittings. 2 year bumper-to-bumper limited warranty. Hydrus Droplet Length 25 in (635 mm) Width 38 in (965 mm) Height in (732 mm) Weight (Dry) 800 lbs. (318 kg) Gallons per Minute 20 GPM (75.71 LPM) Pump Pressure 1450 PSI (100 bar) Nozzle Pressure 1250 PSI (86 bar) Foam Tank Size 12 Gallons (45 L) Foam Proportioning System Our Hydrus Skid Series, UTV Series and Droplet come standard with our foam proportioning system. Using a venturi effect, this injects foam into the water with concentrations of 0.5% to 6.0%. Our system is rated to use Class A, Class B and AFFF type foams. *Height, length, width and weight depend on available apparatus space, chassis requirements and GVWR. All weights are approximate. Schedule a product demonstration today! 16 HMAFIRE.COM
17 HMA FIRE Hydrus Ultimate System- NEW Hydrus Ultimate Length 29 in (0.74 m) Width 48 in (1.22 m) Height 32 in (0.81 m) Weight (Dry) Gallons per Minute Pump Pressure Nozzle Pressure 450 lbs. (204 kg) 30 GPM (114 LPM) 1450 PSI (100 bar) 1250 PSI (86 bar) Foam Tank Size 12 Gallons (45 L) SPECIFICATIONS *Height, length, width and weight depend on available apparatus space, chassis requirements and GVWR. All weights are approximate. Hydrus 30 Run Dry UHP PTO Driven- Hydraulically Controlled System - Ceramic cylinders and seals to improve pump life and lower maintenance - Variable pressure settings and flow from GPM through IQAN Controls FoamPro or similar foam system Touch Screen System Controls Water and Foam Auto-fill Water and Foam Level Indicator Lights Low-level sensor and auto-system shutdown for low water levels. Hannay electric rewind hose reel with 200 of 3/4 hydraulic hose line. Corrosion resistant high pressure brass and stainless steel fittings. 2 year bumper-to-bumper limited warranty. Hannay Hose Reel As the industry leader in hose reels, Hannay has made a reel to handle the pressures of UHP. All our Hydrus Series Units come standard with electric rewind hose reels FIRE 17
18 Hydrus UTV Series
19 HMA FIRE ULTRA HIGH PRESSURE FIRE SUPPRESSION SYSTEMS MOBILE UHP DEPLOYMENT Off-Road Fire Attack HMA Fire s Ultra High Pressure (UHP) Hydrus UTV Series are designed to be easily installed on any UTV. They are intended for fire attack on fuel fires, forest and wildlands fires, and fires within parking garages, warehouses, and other facilities. This series features EMS capabilities including a standard Stokes Basket Tray with tie down functionality (Stokes Basket sold separately). These units are selfcontained and incorporate a state-of-the-art UHP fire suppression system powered by a gasoline or diesel engine. FOLLOW US ON
20 HMA FIRE Hydrus UTV OPTIONS Hydrus 10 Run-Dry UHP Piston Plunger Pump - Honda 13 HP V-Twin GX series gasoline engine 100 gallon water tank option Diesel Drive Option Kit Water/ Foam Auto-Fill Valve Water/ Foam Level Indicators Front Bumper Winch SPECIFICATIONS System integration on your choice of UTV. Hydrus 20 Run-Dry UHP Piston Plunger Pump Honda 22 HP V-Twin GX series gasoline engine certified for fire suppression. HMA Venturi foam system: Adjustable from 0.5% to 6% with Class A, Class B or AFFF foam. Industry exclusive auto throttle that activates when the nozzle bale is opened. Manual Throttle Control Low-level water sensor and auto- system shutdown for low water levels. 5.6 gallon, chassis independent fuel tank Hannay electric rewind hose reel with 200 of ¾ hydraulic hose line. Corrosion resistant high pressure brass and stainless steel fittings. 2 year bumper-to-bumper limited warranty. Hydrus UTV Length in (1.61 m) Width 60 in (1.52 m) Height in (1.32 m) Auto/Manual Throttle Control Our Hydrus Series Units are designed to throttle up to 1450 PSI and your set flow when you open the bail. With all of our units, except for our 10 GPM systems, you have the option to change that to manual mode to control your pressure and flow with the throttle on the Honda engine. Weight (Dry) Weight (Wet) 1150 lbs. (522 kg) 1985 lbs. (900 kg) Start/Charge Nozzle Control Gallons per Minute 20 GPM (75.71 LPM) Pump Pressure 1450 PSI (100 bar) Nozzle Pressure 1250 PSI (86 bar) Water Tank Size 100 Gallons (379 L) By the turn of this valve, your nozzle becomes charged. You can do this at the pump panel before you deploy your hand line due to our use of a booster reel. Foam Tank Size 12 Gallons (45 L) *Height, length, width and weight depend on available apparatus space, chassis requirements and GVWR. All weights are approximate. Schedule a product demonstration today! 20 HMAFIRE.COM
21 HMA FIRE Hydrus UTV EMS SPECIFICATIONS OPTIONS EMS Cabinets Diesel Drive Option Kit Water/ Foam Auto-Fill Valve Water/ Foam Level Indicators Front Bumper Winch System integration on your UTV of choice * EMS Skid Tray (Stokes Basket Sold Separately) Hydrus 10 Run-Dry Piston Plunger Pump Honda 13 HP V-Twin GX series gasoline engine HMA Venturi foam system: Adjustable from 0.5% to 6% with Class A, Class B or AFFF foam. Industry exclusive auto throttle that activates when the nozzle bale is opened. Manual Override Throttle Control Low-level water sensor and auto- system shutdown for low water levels. 5.6 gallon, chassis independent fuel tank Hannay electric rewind hose reel with 100 of ½ hydraulic hose line. Corrosion resistant high pressure brass and stainless steel fittings. 2 year bumper-to-bumper limited warranty *Depends on UTVs weight carrying capacity Hydrus UTV EMS Length in (1.61 m) Width 60 in (1.52 m) Height 50 in (1.27 m) Weight (Dry) 750 lbs. (340 kg) Weight (Wet) 1335 lbs. (606 kg) Gallons per Minute 10 GPM (37.85 LPM) Pump Pressure 1450 PSI (100 bar) Nozzle Pressure 1250 PSI (86 bar) Water Tank Size 70 Gallons (265 L) 80 Micron Mesh Foam Filter Foam filter included in every Hydrus Series System and designed to filter out foam contaminants to extend the longevity of your system. Foam Tank Size (Integrated) 10 Gallons (45 L) *Height, length, width and weight depend on available apparatus space, chassis requirements and GVWR. All weights are approximate FIRE 21
22 ULTRA HIGH PRESSURE SUMMITS Hands-on Educational Training Ultra High Pressure Summits are your opportunity to get hands-on, live fire training from experts around the United States that have deployed and researched with the technology. This is a free event that is sponsored by HMA Fire and various other vendors in the industry to ensure that when you go and attack a fire that you are as educated as possible. We believe that in an industry where your life or someone else s life can be taken at any moment, being trained and educated is the most valuable asset. These Ultra High Pressure Summits consist of two days of training. The first night includes presentations that cover the science behind UHP, overview of the research on UHP, and the strategies and tactics of an UHP Rapid Response Model. The next day is hands-on training where participants get to put UHP to the test first hand on a car or structural fire attack. Education is Our Goal These UHP Summits began in September of 2017 when the Middleton (WI) Fire District hosted their first annual UHP Summit sponsored by HMA Fire. Since then, the Middleton Fire Team of Instructors and HMA Fire have put on five summits in three different states educating more than 350 firefighters. HMA Fire s goal out of these UHP Summits isn t to get a sale, but to bring together a group of firefighters, build up comradery and learn the strategic benefits of UHP in the modern setting of fire behavior. We recommend, no matter what your skill level with UHP, to attend a Summit and see how departments through the states are starting to harness the power of this technology. We hope to catch you at one! Interested in hosting or attending a summit? Contact us today to learn more! FIRE info@hmafire.com HMAFIRE.COM
23 A RELATIONSHIP FOR HMA FIRE ULTRA HIGH PRESSURE FIRE SUPPRESSION SYSTEMS THE FUTURE OF MOTORSPORTS HMA FIRE In the summer of 2017, HMA Fire set out to supply motorsports rescue teams with a new and innovative technology; Ultra High Pressure Fire Suppression. The goal was to provide this suppression technology to allow for a rapid response and rapid deployment of water to car fires, fuel fires and mobile home fires without the excessive use of water. Debut of HMA s Skid Units at the Daytona 500. A demonstration of HMA Fire s UHP system was scheduled to take place with Daytona International Speedway (DIS) and the International Speedway Corp. (ISC). Through presentation and hands-on testing of the equipment at the speedway, it became clear that Daytona International Speedway had a want for this technology. HMA Fire delivered two 20 GPM Skid units to the Daytona International Speedway in early These skid units were quickly put into service and had their debut during the 2018 Speedweeks events, which concluded with The Great American Race : the DAYTONA 500. We are happy that the relationship with Daytona International Speedway successfully supplied their rescue team with a tool that will help to make their jobs of protecting life and property safer, more effective and more efficient. It is our belief that having units at Daytona International Speedway is a true testiment to the quality and effectiveness of Ultra High Pressure. It is our hope that the relationship with DIS brings the technology of UHP to other race tracks. DIS SKID UNITS Daytona International Speedway was supplied with two UHP skid units: Flows 20 GPM at 1450 PSI 200 of 3/4 hose line 150 gallon water tank with a 12 gallon foam tank Auto/Manual Throttle Control Aluminum skid tray assembly Usage of 1/5th the water allowing for a dryer speedway FOLLOW US ON
24 HMA FIRE ULTRA HIGH PRESSURE FIRE SUPPRESSION SYSTEMS 400 Quality Court Fall River, WI FIRE(3473) 2018 HMA Fire LLC All rights reserved. Specification subject to change without prior notice.
SPECIALISTS IN INDUSTRIAL PROTECTION
SPECIALISTS IN INDUSTRIAL PROTECTION commitment PASSION FOR EXCELLENCE KME Works for You. As a privately held family company since 1946, KME is truly a success story. We ve experienced six decades of steady
More informationTWO TIMES THE FIGHT Twin-Agent Fire Suppression Systems
TWO TIMES THE FIGHT Twin-Agent Fire Suppression Systems A TOUGH SOLUTION FOR TOUGH FIRES No fire should be taken lightly. Yet, there are some that go far beyond a typical fire. These extremely hazardous
More informationPOWERFUL CUSTOMIZED SOLUTIONS UNMATCHED QUALITY
Vactor celebrates over 45 years as your powerful sewer cleaning partner. For nearly 50 years, Vactor Manufacturing has been the leader in building combination sewer cleaners with technological innovation
More informationTECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)
TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST) TRUCK, FIRE FIGHTING, 4x4, MODEL 1350 PKP/200 AFFF NSN 4210-00-484-5729
More informationteambrite Supply Steambrite Supply Created on: : Thursday 18 April, 2019
Model Number: 157595 NorthStar 157595 Trailer Hot Water Pressure Washer Honda Engine 4 GPM 4000 PSI with Fresh Tank FREE Shipping!Forklift Unload ONLY! Manufacturer: Northern Tool & Equipment 57595 Trailer
More informationANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS
ANSUL Twin-Agent Fire Fighting/Securing Systems Specifications Models 450/50-B, 450/100-B, 900/100-B INDEX 1.0 GENERAL 1.1 References 1.2 Submittals 1.3 System Capabilities 1.4 Quality Control 1.5 Warranty,
More informationTwin-Agent Fire Fighting/Securing Systems Specifications
Twin-Agent Fire Fighting/Securing Systems Specifications Models 450/50, 450/100, 900/100 & 1350/200 INDEX 1.0 GENERAL 1.1 References 1.2 Submittals 1.3 System Capabilities 1.4 Quality Control 1.5 Warranty,
More informationFANERGY Far more than just a fan.
FANERGY Far more than just a fan. Protects emergency crews. Saves lives. 2 Rosenbauer FANERGY FANERGY Rosenbauer The crucial difference New All In One Airflow Technology Powerful Pull-out fan unit Largest
More informationFANERGY Far more than just a fan.
FANERGY Far more than just a fan. Protects emergency crews. Saves lives. 2 Rosenbauer FANERGY FANERGY Rosenbauer The crucial difference New All In One Airflow Technology Powerful Pull-out fan unit Largest
More informationAFRL-RX-TY-TR
AFRL-RX-TY-TR-2010-0033 FIELD DEMONSTRATION OF A CENTRIFUGAL ULTRA HIGH PRESSURE (UHP) P-19 Jennifer L. Schroeder Fire Science Solutions, LLC 9117 Sunshine Drive Youngstown, FL 32466 Michael J. McDonald
More informationFoam Systems U.S. Quick Reference Guide
Foam Systems U.S. Quick Reference Guide This guide is intended for general reference only. Prior to the design, layout, and/or installation of any sprinkler system, please refer to Viking s technical documentation
More informationINSTRUCTOR GUIDE COURSE: FIREFIGHTER PRE-BASIC SESSION REFERENCE: 1 TOPIC: ORIENTATION AND FIRE BEHAVIOR LEVEL OF INSTRUCTION:
COURSE: FIREFIGHTER PRE-BASIC SESSION REFERENCE: 1 INSTRUCTOR GUIDE TOPIC: ORIENTATION AND FIRE BEHAVIOR LEVEL OF INSTRUCTION: TIME REQUIRED: THREE HOURS MATERIALS: APPROPRIATE AUDIO VISUAL AIDS REFERENCES:
More informationSuper Combi. A reliable partner when there is a job to be done. No matter how tough the job is, Super Combi will take care of it!
Rolba SUPER COMBI Super Combi A reliable partner when there is a job to be done. No matter how tough the job is, Super Combi will take care of it! Many years of experience and feedback from our customers
More informationTheory of Operation: How Parts Cleaning Works
Theory of Operation: How Parts Cleaning Works MART defines the term to clean as to overpower the soils. The MART Parts Washer is a high-impact pressure, high-temperature, industrial water-based cleaning
More informationWATER MIST CONVENTION AND EXHIBITION
INTERNATIONAL WATER MIST ASSOCIATION IWMA SEMINARS S ON WATER MIST TECHNOLOGY DUBAI INTERNATIONAL CONVENTION AND EXHIBITION CENTRE Water mist fire protection: The most innovative fire fighting technology
More informationFire Suppression Performance of Manually Applied CAF and Other Water Based System
Fire Suppression Performance of Manually Applied CAF and Other Water Based System Andrew Kim and George Crampton Fire Suppression Research and Applications A Technical Working Conference (SUPDET2012) Outline
More informationWater Mist Fire Suppression
Water Mist Fire Suppression How less water has a big impact. HELPING PROTECT YOUR BUSINESS AND VALUED ASSETS WITH WATER MIST FIRE PROTECTION SYSTEM INTRODUCTION Many buildings have specific areas that
More informationEssentials of Fire Fighting, Fourth Edition Transition Guide. Chapter 1: The History of the Fire Service (Essentials, Chapter 1)
Essentials of Fire Fighting, Fourth Edition Transition Guide Chapter 1: The History of the Fire Service (Essentials, Chapter 1) This chapter covers the history of the fire service, the organization of
More informationHigh-Pressure Water Mist systems for the protection of shopping centres in historical city centres
Danfoss Fire Fighting High-Pressure Water Mist systems for the protection of shopping centres in historical city centres Presenter: Antonio Terio October 25 th 2017, IWMC Rome 1 Introduction & Background
More informationSPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING
THE MOST ADVANCED TECHNOLOGY FOR PROTECTING SPECIAL HAZARDS There are numerous hazards where the use of dry chemical is the best option for firefighting, and where the use of portable fire extinguishers
More informationParts Washers, Water Pumps, special applications
Parts Washers, Water Pumps, special applications 147 Parts Washers Storm King Automotive and Industrial Parts Washers Simple Operation Fill the Storm King cleaning basket with parts, close the door, parts
More informationSelf Expanding Foam Fire Suppression System SPECIFICATION SHEET Rev
Self Expanding Foam Fire Suppression System SPECIFICATION SHEET Rev 1.0 03-07-2017 Description Self Expanding Foam Systems (SEFS) are the alternative solution to existing flammable and combustible liquid
More informationMistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. TM TM
MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. TM TM 2 MistMax Low pressure water mist fire suppression skid Our modular fire skid is customised to suit your
More informationNilfisk-ALTO Pressure Washers
Nilfisk-ALTO Pressure Washers Top-quality pressure washers for every cleaning application A Nilfisk-Advance Brand POSEIDON 2-20X Powerful, compact, and mobile cold water cleaning THE POSEIDON 2-20X offers
More informationCENTRAL CALAVERAS FIRE AND RESCUE TRAINING DIVISION CAREER TRAINING AND DEVELOPMENT FIREFIGHTER II STANDARDS
2-1 General FIREFIGHTER II STANDARDS 2-1.1* The Firefighter shall demonstrate an awareness of the Affirmative Action Plan, Employee Discrimination Complaint Procedure, Sexual Harassment, and other employee
More informationIMPORTANCE of FIREGROUND VENTILATION PRACTICES and DYNAMICS IN FIREFIGHTING (PART I)
IMPORTANCE of FIREGROUND VENTILATION PRACTICES and DYNAMICS IN FIREFIGHTING (PART I) By Lt. Mike Mason As we have stated previously there are two prominent areas that drive every fire ground and that is
More informationPublic Comment No. 3-NFPA [ Chapter 7 ]
Page 1 of 8 Public Comment No. 3-NFPA 405-2013 [ Chapter 7 ] Chapter 7 ARFF Personnel Safety and Safety Management 7.1 Scope. This chapter identifies the knowledge and skills necessary to ensure ARFF personnel
More informationPROVEN DEPENDABILITY
PROVEN DEPENDABILITY COMPACT PTO DIRECT DRIVE TRUCKMOUNTS All With over 30 years of refinements and engineering innovation, Cleanco Truckmounts have become known throughout the industry as dependable,
More informationThe frequency of maintenance and service correlates with the frequency the pressure washer is used.
1If the surfaces you are cleaning have any kind of grease or oil, you will need a hot water pressure washer to clean them. Cold water pressure washers are great for cleaning off dirt. If the surface to
More informationCONCRETE CLEANING BEST PRACTICES
CONCRETE CLEANING BEST PRACTICES Let s work together to keep our sidewalks clean and enhance the livability of our cities. At Unimanix Industries, it is our goal to help you get the dirty job done quickly
More informationRotary screw Air compressors. Fixed Speed 5 15HP
SEG Series Rotary screw Air compressors Fixed Speed Rotary screw Air Compressors 5 15HP Some companies are founded on hard work. Others are founded on ideals. FS-Curtis was founded on both. 1854 1857 1876
More informationREPORT DOCUMENTATION PAGE
REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 The public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing instructions,
More informationSan Joaquin County Office of Education Career & Technical Education Fire Fighter Technology CBEDS#: 5833
Fire FighterTechnology Course Outline 1 Introduction to ROP 5.0 0 ROP Philosophy and operation Enrollment forms Emergency cards Class rules and regulations Program expectations and competencies 2 Fire
More informationWe introduced the 2100 Series over 20 years ago, which continues to set the standard in the industry today.
Vactor celebrates over 40 years as your powerful sewer cleaning partner. For over 40 years, Vactor has been much more than a provider of equipment. We re a provider of solutions doing whatever it takes
More informationMAXIMUM KNOCKDOWN ABILITY Large Dry Chemical Fire Suppression Systems
MAXIMUM KNOCKDOWN ABILITY Large Dry Chemical Fire Suppression Systems ANSUL PIONEERED DRY CHEMICAL FIRE PROTECTION IN 1939, WHICH HELPED CREATE LARGE DRY CHEMICAL SYSTEMS WITH SUPERIOR FIREFIGHTING CAPABILITIES
More informationAmerex Fire Suppression Systems. Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond.
Amerex Fire Suppression Systems Because Operators and the Environment are NOT Disposable Quality is Behind the Diamond. Quality is Behind the Diamond. Diamonds have long been a symbol for quality. At Amerex
More informationFoam Products ENGLISH
Foam Products ENGLISH Tyco Fire & Building Products Foam Products Today s technological innovations bring chemical and material fire hazards. Our lines of sprinklers and alarm valves have an excellent
More informationSUBJECT FIRE OPERATIONS GUIDELINE (F.O.G.) #F510 Issued: 1/2014 Last Revision: 1/2014 Pages: 9 By Order Of: J.S. Thompson, Fire Chief
THE COLONY FIRE DEPARTMENT FIRE OPERATIONS GUIDELINE SUBJECT FIRE OPERATIONS GUIDELINE (F.O.G.) #F510 Issued: 1/2014 Last Revision: 1/2014 Pages: 9 By Order Of: J.S. Thompson, Fire Chief Review Reviewed
More informationAtlas Copco. Oil-sealed rotary screw vacuum pumps GVS , cfm
Atlas Copco Oil-sealed rotary screw vacuum pumps GVS 30-400, 35-3000 cfm Reliable general vacuum for critical applications Atlas Copco, the industry leader in compressed air solutions, has transferred
More informationEvidence-based practice in emergency services is typically associated with medical care; but the term refers
Three Things A Fire Chief Should Know About Evidence-Based Fire Suppression By Michael Ward Evidence-based practice in emergency services is typically associated with medical care; but the term refers
More informationSECURITY BLANKET Foam Fire Protection Products
SECURITY BLANKET Foam Fire Protection Products REAL DANGERS DEMAND REAL SOLUTIONS If your business manufactures, stores, or transports flammable liquids, the thought of a devastating fire always burns
More informationALTO POSEIDON 5 WHY COMPROMISE The silent and efficient cold water high pressure cleaner
WHY COMPROMISE The silent and efficient cold water high pressure cleaner 3 New series state of the art with no compromise on quality After more than 40 years of experience in pressure washing and research
More informationPROVEN DEPENDABILITY
PROVEN DEPENDABILITY COMPACT PTO DIRECT DRIVE TRUCKMOUNTS With over 39 years of refinements and engineering innovation, Cleanco Truckmounts have become known throughout the industry as dependable, reliable,
More informationINTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL
INTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL 1- Utilize a pre-incident plan so that the industrial fire brigade member implements the responses detailed by the plan. NFPA 1081, 2012
More informationSKILL VERIFICATION BOOK FIREFIGHTER I MODULE II FIRE PROTECTION BUREAU. Assigned to: Name:
Assigned to: : Skill Book Initiated: Department/District: Identification Number: _ SKILL VERIFICATION BOOK FIREFIGHTER I MODULE II Third Edition September 2004 Meeting the requirements of NFPA 1001, 2002
More informationGUIDELINES FOR THE APPROVAL OF HELICOPTER FACILITY FOAM FIRE-FIGHTING APPLIANCES
E 4 ALBERT EMBANKMENT LONDON SE1 7SR Telephone: +44 (0)20 7735 7611 Fax: +44 (0)20 7587 3210 GUIDELINES FOR THE APPROVAL OF HELICOPTER FACILITY FOAM FIRE-FIGHTING APPLIANCES MSC.1/Circ.1431 31 May 2012
More informationSecond Revision No. 1-NFPA [ Section No. 2.2 ] Submitter Information Verification. Committee Statement
Second Revision No. 1-NFPA 1410-2014 [ Section No. 2.2 ] 2.2 NFPA Publications. National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02169-7471. NFPA 1500, Standard on Fire Department
More informationDevair and Miscellaneous Table of Contents
Devair and Miscellaneous Table of Contents Get The Compressed Air Quality Your Application Requires... 2 Air Compressors 5 HP and 7 1/2 HP Models... 3 10 HP and 15 HP Models... 3 25 HP and 30 HP Models
More informationPrerequisite/Co-requisite: Pass the reading and writing portions of COMPASS or other accepted testing instrument.
Industrial Fire Protection (FIRT 1347) Credit: 3 semester credit hours (3 hours lecture, 0 hours lab) Prerequisite/Co-requisite: Pass the reading and writing portions of COMPASS or other accepted testing
More informationA safe journey with Dräger CRUISE CATALOGUE
A safe journey with Dräger CRUISE CATALOGUE Introduction ADVANTAGES Total FRS package Fast delivery 24/7, 365 days support Largest FRS product range Top quality Worldwide Dräger locations SAFETY ON BOARD
More informationBid Specifications for Thermo-Lay model UD /4 yard truck mounted machine with hydraulic bins & roller DIMENSIONS: Body:
DIMENSIONS: Body: 142" long, 78" wide, 43" high Total Height above ground: 98" Cab to trunion required: 138" Wheel base required: 204" on Freightliner FL 70 Turning radius: 55' curb to curb on Freightliner
More informationFIRE AND FIRE FITTING By Mr. Prashant Sansare
FIRE AND FIRE FITTING By Mr. Prashant Sansare What is mean by fire? CASE STUDY What Happened? Late one evening, a large storage tank containing a flammable liquid began to overflow. It was not detected
More informationIndependence, Missouri FIRE DEPARTMENT
Annual Report Independence, Missouri FIRE DEPARTMENT LETTER FROM THE CHIEF Fire Station #1 950 N. Spring Street It is my pleasure to present the 16 annual report. In these pages you will find that we have
More informationAdditional Materials: Instructor s PowerPoint, Question Files
Course Delivery Formats: Online Interactive Course Online Streamed Video DVD Additional Materials: Instructor s PowerPoint, Question Files When it comes to mastering the basics for certification or refresher
More informationSafer Fire Fighting. Efficient Fire Fighting. Saving Environment
Safer Fire Fighting Efficient Fire Fighting Saving Environment Cold Cut Systems is the World leader in cold cutting extinguishing technology Cold Cut Systems is the sole supplier of the coldcut cobra cutting
More informationADVANCED EXTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL
ADVANCED EXTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL 1- Utilize a pre-incident plan so that the industrial fire brigade member implements the responses detailed by the plan. NFPA
More informationEXTINGUISHMENT AND BURNBACK TESTING OF FIRE FIGHTING AGENTS
AFRL-ML-TY-TR-2005-4581 EXTINGUISHMENT AND BURNBACK TESTING OF FIRE FIGHTING AGENTS Kimberly D. Barrett Jennifer L. Kalberer Applied Research Associates, Inc. P.O. Box 40128 Tyndall AFB, FL 32403 Interim
More informationSummary. firefighter training in Since that time the firefighter had attended semi-annual
Summary On August 25, 2005 a live fire training exercise was conducted at a North Carolina County airport. Personnel involved in the training evolution were three employees of the airport who were employed
More informationFirst Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM
First Revision No. 1-NFPA 1403-2015 [ Section No. 1.2.1 ] 1.2.1 The purpose of this standard shall be to provide a process for conducting live fire training evolutions to ensure that they are conducted
More informationFire Apparatus and Equipment Since 1960 BUILD SERVICE REPAIR REFURBISH
GOWANS - KNIGHT Fire Apparatus and Equipment Since 1960 BUILD SERVICE REPAIR REFURBISH Here at Gowans-Knight we specialize in meeting customers needs and expectations for unmatched quality and service!
More informationGround-engaging telehandler
Ground-engaging telehandler Reaching new heights in versatility. TH522 Loading, moving, lifting, placing - the Wacker Neuson TH522 handles a lot. But there s more. This highly versatile telehandler extends
More informationAddressing Myths Often Generated By Private EMS Providers
Addressing Myths Often Generated By Private EMS Providers Private EMS, and specifically ambulance service providers, continue to make proposals to Metro and medium size cities to replace the local fire
More informationMistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.
MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. 2 MistMax Low pressure WaterMist fire suppression skid Our modular fire skid is customised to suit your specific
More informationWHIRLWIND - POWERFUL, DURABLE VACUUM SWEEPER
Whirlwind WHIRLWIND - POWERFUL, DURABLE VACUUM SWEEPER Need a powerful vacuum sweeper that not only cleans but is durable, easy to operate and easy to maintain? The Elgin Whirlwind is the answer. Suited
More informationEASTERN ARIZONA COLLEGE Fire Department Operations II
EASTERN ARIZONA COLLEGE Fire Department Operations II Course Design 2015-2016 Course Information Division Allied Health Course Number FSC 102 Title Fire Department Operations II Credits 5 Developed by
More informationHALON FLIGHTLINE EXTINGUISHER EVALUATION: DATA SUPPORTING STANDARD DEVELOPMENT [INCLUDES NOVEMBER 2007 ADDENDUM]
AFRL-RX-TY-TR-2008-4573 HALON FLIGHTLINE EXTINGUISHER EVALUATION: DATA SUPPORTING STANDARD DEVELOPMENT [INCLUDES NOVEMBER 2007 ADDENDUM] John R. Hawk Applied Research Associates P.O. Box 40128 Tyndall
More informationINDUSTRIAL LAUNDRY EQUIPMENT FOR VENDED LAUNDRY APPLICATIONS WASHER-EXTRACTORS I TUMBLE DRYERS SMALL CHASSIS EQUIPMENT
INDUSTRIAL LAUNDRY EQUIPMENT FOR VENDED LAUNDRY APPLICATIONS WASHER-EXTRACTORS I TUMBLE DRYERS SMALL CHASSIS EQUIPMENT IPSO : Built for Commercial Dependability IPSO has been the driving force behind some
More informationBased on NFPA 1003: Standard for Airport Fire Fighter Professional Qualifications 2015 Edition
Based on NFPA 1003: Standard for Airport Fire Fighter Professional Qualifications 2015 Alabama Fire College Airport Firefighter Instructional JPR Verification Sheet Full Name: Fire Department: This Instructional
More informationBurned Dozer 230. I m just glad we get to do this the RLS process so others can learn something from it. Dozer Operator
Event Type: Dozer Fire Date: September 7, 2018 Location: Tepee Fire, Oregon Burned Dozer 230. I m just glad we get to do this the RLS process so others can learn something from it. Dozer Operator Background
More informationteambrite Supply Manufacturer: Northern Tool & Equipment
Model Number: 20130711 Clean Storm 38hp Synergistic Trailer Truckmount Package Pressure Washer Vacuum Recovery Machine Flood Pumper Manufacturer: Northern Tool & Equipment Clean Storm Synergistic Truckmount
More informationCOLD WATER - WHY COMPROMISE. professional cold water pressure washers
COLD WATER - WHY COMPROMISE professional cold water pressure washers NEW Nilfisk-ALTO POSEIDON 3 Compact, cost efficient and powerful - the newest addition to the POSEIDON family Launch of the new Nilfisk-ALTO
More informationYankee Dryer Safety. Program
Program Yankee Program Objectives Personnel protection Loss Prevention Asset Optimization What is a Yankee? It is a Cast iron Pressure vessel In compliance with American Society of Mechanical Engineering
More informationTECHNICAL DATA 3% AR-AFFF
June 25, 21 Foam 14a The Viking Corporation, 21 N Industrial Park Drive, Hastings MI 4958 Telephone: 269-945-951 Technical Services: 877-384-5464 Fax: 269-818-168 Email: techsvcs@vikingcorp.com 1. DESCRIPTION
More informationMunicipal, Utility, Oil & Gas
Municipal, Utility, Oil & Gas Key hole repairs Water or air excavation Precise excavation Slot trenching Water valve box repair or utility & line locating Visually locate underground utilities in tight
More informationChapter 17 Test. Directions: Write the correct letter on the blank before each question.
Chapter 17 Test Name: Date: Directions: Write the correct letter on the blank before each question. Objective 1: Describe initial factors to consider when suppressing structure fires. 1. Which strategy
More informationpressure washers residential commercial
pressure washers residential commercial pressure vehicles boat ATV / UTV windows siding porch exterior walls deck roof maintenance pool covers / tarps patio washers residential and commercial landscaping
More informationConco FinTech ACC AIR-COOLED CONDENSER CLEANING
Conco Systems 530 Jones Street Verona, PA 15147 USA Toll Free: 1-800-345-3476 Ph (412) 828-1166 Fax (412) 826-8255 Email: info@concosystems.com Web: www.concosystems.com Conco FinTech ACC can restore heat
More informationWAS STARTED BY CARLOS BAHAMONDES MASAFIERRO
WWW.WATERMIST.CL WWW.WATERMIST.CL WAS STARTED BY CARLOS BAHAMONDES MASAFIERRO ALTHOUGH SOLUTIONS SUCH AS THESE ARE NOW MORE IMPORTANT THAN EVER IN TIMES OF SEVERE DROUGHT, CARLOS BAHAMONDES MASAFIERRO
More informationPOSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS
FIRE EXTINGUISHING INSTALLATIONS SECTION POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS Version 1 29-09-04 0 Eurofeu position paper on water mist for fire fighting applications 1 Scope The
More informationManufactured in the USA by IZESP!UFL. February 2015
2 HOT POWER Manufactured in the USA by GO WASHER IZESP!UFL February 2015 HOT POWER WASHER: ELECTRIC POWERED, DIESEL HEATED The HV Series combines the cleaning power of high pressure with the grease cutting
More information2014 OVFA Conference. June 18-21, 2014 Lincoln City, Oregon
2014 OVFA Conference Hosted by North Lincoln Fire & Rescue, Central Oregon Coast Fire & Rescue, Depoe Bay RFPD, Newport Fire Department, Nestucca RFPD, Toledo Fire Department, Siletz RFPD, Seal Rock RFPD,
More informationTECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)
TM 5-4210-228-14&P-2 TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST) TRUCK, FIRE FIGHTING, 4x4, MODEL 1350 PKP/200 AFFF
More informationPOWER WASHERS. industrial. commercial. residential
POWER WASHERS residential commercial industrial vehicles boat ATV / UTV windows siding porch exterior walls roof maintenance pool covers / tarps patio Residential Commercial Industrial landscaping / leaves
More informationA.U.P.C.I ASOCIACIÓN URUGUAYA DE PROTECCION CONTRA INCENDIO AUPCI
A.U.P.C.I ASOCIACIÓN URUGUAYA DE PROTECCION CONTRA INCENDIO Foam Overview Applications Flammable Liquid Storage Tanks Diked Storage Tanks Loading Racks/Transfer Stations Closed Head Sprinkler Systems Deluge
More informationFIRE PROTECTION BUREAU ACCREDITATION AND CERTIFICATION PO Box Olympia WA (360) FAX: (360) AIRPORT FIREFIGHTER
5.2 RESPONSE 5.2.1 Responding to Incidents Daytime Evaluation Sheets: 5.2.1; 5.3.6 Skill Sheet: A Birth STANDARD: 5.2.1 and 5.3.6 TASK: Respond to a daytime incident or accident on and adjacent to the
More informationCONFINED SPACE VENTILATION
CONFINED SPACE VENTILATION Version 1.0 1 DESIGNING THE FUTURE At Pearson Industries we understand that tough jobs require tougher tools, and for this industry, our fans have been designed to outperform
More informationPressure Washers (courtesy of Mi-T-M Corp.)
Pressure Washers (courtesy of Mi-T-M Corp.) What is pressure washing? Pressure washing or power washing is the growing practice of cleaning using high pressure water spraying. The high pressure water spraying
More informationTECHNICAL MANUAL OPERATOR S, ORGANIZATIONAL, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL IINCLUDING REPAIR PARTS AND SPECIAL TOOLS LISTI FOR
TM 5-4210-222-14&P-3 TECHNICAL MANUAL OPERATOR S, ORGANIZATIONAL, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL IINCLUDING REPAIR PARTS AND SPECIAL TOOLS LISTI FOR TRUCK, FIREFIGHTIN6G DRY CHEMICAL
More informationFlexible Solutions for Air Quality
Flexible Solutions for Air Quality Doosan Portable Power understands the importance of clean air Clean air is essential to the safety and efficiency of countless compressed air applications. Without it
More informationLassen Community College Course Outline
Lassen Community College Course Outline FS 93 Fire Fighter 1 18.5 Unit I. Catalog Description This course provides the skills and knowledge needed for the entry level fire fighter, career or volunteer,
More informationFEEL THE COOL FEEL THE MIST
FEEL THE MIST by 1 www.ventomist.com / +1 (281) 724-8222 FEEL THE COOL FEEL THE MIST Ventomist: Greater Innovation, Lower Prices and Higher Quality in Portable and Fixed Misting Systems Misting systems
More informationTURNOUT GEAR DRYERS. 4-Unit Turnout Gear Dryer with Touchscreen Control Four Drying Units; 4 Helmet Dryers;12 Accessory Ports
DRY GEAR FAST. TURNOUT GEAR DRYERS Firefighters need to be ready for action not delayed with wet gear. Ram Air Gear Dryers get you back to action in a fraction of the time! They safely and quickly dry
More informationThe Next Generation of Foam Fire Suppression. Automatic CAF Fire hose reel system FEATURES
Fire hose reel system The first automatic CAF, fire hose reel system FEATURES The Automatic CAF Fire Hose Systems are ideal for firefighting needs in locations that require foam as a fire fighting agent.
More informationpower washers residential commercial
power washers residential commercial vehicles boat ATV / UTV windows siding porch exterior walls deck roof maintenance pool covers / tarps patio residential and commercial landscaping / leaves fencing
More informationWILLIAM HICKS. MSc, CFEI, CFPS, IAAI-CFI, MIFireE, EFO, CFOD, F-IAFI. Associate Professor Eastern Kentucky University
Foam Systems WILLIAM HICKS MSc, CFEI, CFPS, IAAI-CFI, MIFireE, EFO, CFOD, F-IAFI Associate Professor Eastern Kentucky University William.Hicks@eku.edu Objectives Classify high, medium, and lowexpansion
More informationSaskatchewan Evaluation and Certification Guide. Appendix D
Saskatchewan Evaluation and Certification Guide Appendix D NFPA 1002 Fire Apparatus Driver/Operator Professional Qualifications Revised 2013 Emergency Management and Fire Safety Page 1 of 13 Table of Contents
More informationBUILDING INDUSTRY TUNNEL RAIL TUNNEL FIRE FIGHTING WITH HIGH PRESSURE WATER MIST
BUILDING INDUSTRY TUNNEL RAIL TUNNEL FIRE FIGHTING WITH HIGH PRESSURE WATER MIST FIRE FIGHTING IS RESPONSIBILITY Fire monitoring Fire detection Fire suppression We are a leading international supplier
More informationCorporate Profile. Firefox Fire Solutions Inc. Toll Free:
Corporate Profile When fire strikes, we help ensure that it can be quickly suppressed by responders. We are leading the way in providing innovative and technologically advanced products used to combat
More informationNew insights into ventilation
New insights into ventilation The International Fire Instructors Workshop (IFIW) gathered in March 2011 in Indianapolis. Numerous firefighters and scientists were there to give lectures. Several of these
More informationCarbon Dioxide Fire Suppression Systems
Carbon Dioxide Fire Suppression Systems The original "clean agent," carbon dioxide suppresses fire without leaving behind water, foam or dry chemical to damage sensitive equipment. And because there is
More information