Wireless Smart Metering LAN-WMBUS-M. Wireless MBUS, door and window sensor. With optional glass break accessory.

Size: px
Start display at page:

Download "Wireless Smart Metering LAN-WMBUS-M. Wireless MBUS, door and window sensor. With optional glass break accessory."

Transcription

1 Wireless Smart Metering LAN-WMBUS-M Wireless MBUS, door and window sensor. With optional glass break accessory. The LAN-WMBUS-M (I/A) (G)/(E)- is a activity sensor for detecting for example openings/closing of windows, doors etc. It can also be used for counting the number of openings in a certain timeframe. The sensor can be ordered in different configurations see the product matrix for more details. The devices have the following features. Wireless MBUS EN /4:2013 Standard. S, T and C- mode are supported. Superb antenna design and high output power for long range. Onboard Magnet sensor. Possibility to connect external wired magnet detector (E) Possibility to connect external wired glass break detector (G) Values can be send instantaneous (I) or accumulated (A). Sabotage detection if sensor is opened or removed from wall. AES 128 encryption. CBC Mode 5 OMS compliant. Very long battery lifetime, up to 14 years. Depending on how many openings, and MBUS-mode. Wide operating temperature range - 20 to +55 degree C. (other temperatures upon request) Plug & Play. Works right out the box, no complex installation needed. Low battery alarm. Available with optional high quality battery.

2 Product description The device is made up of a sensor and a magnet. Whenever the magnet is removed or returned to the sensor a message is sent (I-variant). The number of passages can also be accumulated and the total number of passages is transmitted in even intervals (A- Accumulated). Is also possible to further enhance the device by connect an external magnet detector through cabling (E-variant) or connect it to Lansen Glass Break device (G). Product Matrix Article Number External External Inputs interface LAN-WMBUS-M - - LAN-WMBUS-ME Magnet 2 LAN-WMBUS-MG GlassBreak 1 SE

3 Radio characteristics Frequency Chiprate S-Mode MHz T-Mode Mhz C-Mode Mhz S-Mode kcps T-Mode 100 kcps C-Mode 100 kcps Datarate S-Mode Chiprate /2 T-Mode Chiprate x 2/3 C-Mode Chiprate RF output power Antenna Transmission intervals accumulated values Retransmission 12dBm Integrated 15 minutes (other intervals are also available). 30 seconds during the first 4 minutes after powerup. 3 times for alarm (sabotage, Alarm) 2 times for other messages. Power and battery Power consumption Battery type Max 40 ma, SAFT LS V - AA Primary Li-SOCL2 (recommended) Max operating voltage 3.6V Minimum operating voltage 2.8V Lifetime Typical more than 10 years. W-MBUS Info Header type EN APPLAYER LONG TRANSPORT HEADER (0X72) Encryption AES 128 CBC (mode 5) Sensor type Low battery warning Manufacture code 0x1D Door and Window device. Yes LAS (standard, other code if requested) SE

4 -A and -I variant Accumulated value. Example: DATA_FIELD_BCD_12_DIGIT; H.C.A Number of openings detected 12 BCD digits, instantiations accumulated value from the power up of the device Data is sent using H.C.A. That is unconverted data value. 0x0E 0x6E 0x01,0x23,0x45,0x67,0x89,0x12 Sabotage Detected Message. The sabotage message is always sent in two ways: Sabotage using Error Flag message. The message is only sent when the status of sabotage is changed. X->don t care that is not affected by the changed alarm condition. 0x02; (DIF field 2 byte integer) 0xFD; (VIF Extension table) 0x17; (VIFE Error flags binary manufacture specific 16 bits) (2 bytes) Sabotage detected.xxxx1 (Bit 0) Sabotage restored.xxxx1 (Bit 0) Sabotage using the manufacture specific status-byte in EN APPLAYER LONG TRANSPORT HEADER (0X72). The bit is set to 1 as long as sabotage is detected. Sabotage detected 1 (Bit 5) Sabotage restored 0 (Bit 5) Low battery Low battery is sent using the power low bit in the status-byte in EN APPLAYER LONG TRANSPORT HEADER (0X72) EN :2013 Table 7 Coding of the status field Battery low 1 (Bit 2) Battery OK 0 (Bit 2) -I Only variant Alarm sent etc using the following encoding if any of the 3 alarm status have changed. The current status of the all 3 alarm ports are sent. X->don t care, that is not affected by the changed alarm condition. Alarm message is sent using Error Flag message as soon as the alarm status is changed. 0x02; (DIF field 2 byte integer) 0xFD; (VIF Extension table) 0x97; SE

5 . 0x1D; (VIFE Error flags binary 16 bits) (2 bytes) Alarm detected (door opened) XXXXXX1XX (Bit2) -> Any Reed are IN alarm condition (any door open) Alarm restored (door closed) XXXXXX0XX (Bit2) -> Reeds are NOT in alarm condition (all doors closed) Examples: X is don t care and is not affected by the change in alarm condition.. Operating conditions Storage temperature Operating temperature, Relative moisture - 55 to + 85 gr C -20 to + 55 gr C (other temperature upon request) Less than 95% non-condensing Casing Colour Dimensions Material White 25,5 x 105 x 22 mm ABS Conformity EMC EN Safety EN Radio EN SE

6 Features for easier installation. Red LED indication when sabotage is detected Red LED indication when sabotage is restored When: When the device is opened or removed from the wall. (sabotage is detected) What: The LED flashes for 4 seconds at 4 Hz. Why: In order to verify that the sabotage detection is working. When: When the device is closed or placed against the wall again(sabotage is restored) What: The LED flashes for 2 seconds at 1 Hz. Why: In order to verify that the sabotage is restored and the device is closed and mounted correctly. Red LED indication of Alarm. When: When the magnet is removed from the device the red led is lit. This only apply to the first 4 minutes of operation (after battery is inserted) What: The LED is lit during alarm condition (door is opened) and turned off again after the magnet is placed nearby the device again ( door is closed) Why: In order to verify that the magnet and device is correctly mounted and is working as intended. Changelog Revision 1.1 Changed the packet type for sabotage and Alarm to better Martin comply with the Alarm message in the MBUS standard. The Hallberg new version is used in software version 2 of the LAN- WMBUS-M. Corrected the physical size of the device. Added information for the RED led during alarm condition. Changed device type from 0x1B to 0x1D SE

Smart Wireless Devices LAN-WMBUS-M. Wireless MBUS, door and window sensor. With optional glass break accessory.

Smart Wireless Devices LAN-WMBUS-M. Wireless MBUS, door and window sensor. With optional glass break accessory. Smart Wireless Devices LAN-WMBUS-M Wireless MBUS, door and window sensor. With optional glass break accessory. The LAN-WMBUS-MI/A (G)/(E)- is a activity sensor for detecting for example openings/closing

More information

RAE Systems. Using the MeshGuard. Protection Through Detection

RAE Systems. Using the MeshGuard. Protection Through Detection RAE Systems Using the MeshGuard Protection Through Detection Turning on the MeshGuard Hold down the [M] key and release it when the MeshGuard beeps. The MeshGuard performs a selftest, followed by warm-up

More information

USER MANUAL COMBOX.L ATEX. Long Range Low Power Wireless Logger For The High-Risk ATEX Conditions

USER MANUAL COMBOX.L ATEX. Long Range Low Power Wireless Logger For The High-Risk ATEX Conditions USER MANUAL COMBOX.L ATEX Long Range Low Power Wireless Logger For The High-Risk ATEX Conditions 1 Solvera Lynx d.o.o. Stegne 23A SI-1000 Ljubljana T +386 1 40 12 860 F +386 1 40 12 861 W solvera-lynx.com

More information

Universal Sensor. Installation Guide. t: f: e: w: uk.tunstall.com Version: V2.97 (421V0R1.

Universal Sensor. Installation Guide. t: f: e: w: uk.tunstall.com Version: V2.97 (421V0R1. Universal Sensor Installation Guide t: 01977 661234 f: 01977 660562 e: enquiries@tunstall.com w: uk.tunstall.com Version: V2.97 (421V0R1.18) Contents 1. Features and Introduction... 3 Your Universal Sensor...3

More information

User manual. ABB i-bus EIB. Zone Terminal MT/S Intelligent Installation System ABB STOTZ-KONTAKT

User manual. ABB i-bus EIB. Zone Terminal MT/S Intelligent Installation System ABB STOTZ-KONTAKT User manual ABB i-bus EIB Zone Terminal MT/S 4.12.1 Intelligent Installation System ABB STOTZ-KONTAKT 2 Contents Page 1 Device configuration..................................... 4 1.1 Introduction..........................................

More information

SonoSelect and SonoSafe Energy Meters

SonoSelect and SonoSafe Energy Meters Installation & User Guide Energy Meters 09/2017 Danfoss VUIGB802 1 www.heating.danfoss.com Danfoss A/S DK-6430 Nordborg Denmark CVR nr.: 20 16 57 15 Telephone: +45 7488 2222 Fax: +45 7449 0949 EU DECLARATION

More information

WIRELESS NETWORK USER MANUAL MHz RFT-868-PIR Wireless Passive Infrared Sensor

WIRELESS NETWORK USER MANUAL MHz RFT-868-PIR Wireless Passive Infrared Sensor WIRELESS NETWORK USER MANUAL 868.3 MHz RFT-868-PIR Wireless Passive Infrared Sensor Device Specifications Power Supply: 3V (2xAAA battery) Current Draw in standby mode: 12µA Temperature Working Range:

More information

GSM RFID VOICE Alarm System

GSM RFID VOICE Alarm System GSM RFID VOICE Alarm System User s Manual For a better understanding of this product, please read this user manual thoroughly before using it. CONTENTS [Function Instruction] [Control Panel] Control Panel

More information

Smart Wireless Sensor

Smart Wireless Sensor Smart Wireless Sensor G7 G7 creates the IoT platform of sensor data exchange and integration 64 wireless sensors each station * temperature, humidity, analog sensors, or digital alarm Windows / ios / Android

More information

Badge Reader BR Installation Guidelines. Product Summary

Badge Reader BR Installation Guidelines. Product Summary Badge Reader BR651 PRODUCT INSTALLATION SHEET Made by RSI VIDEO TECHNOLOGIES 2208-BRIS March 2012 Product Summary The Outdoor Badge Reader BR651 is designed for use in operating a Videofied security system.

More information

E529 Smart Digital Thermostat Product Guide

E529 Smart Digital Thermostat Product Guide E529 Smart Digital Thermostat Product Guide Table of Contents Table of Contents... Page 1 Overview and General Concept... Page 2 Application... Page 3 Features... Page 4 LCD Item Descriptions... Page 5

More information

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no ) Product definition KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no 2343 00) Art. no 2343 00 Page 1 of 22 Product definition Table of contents 1 Product definition... 3 1.1 Product catalogue...

More information

Smartphone Application Development Guide for BatteryMole Bluetooth Battery Monitoring System for Automobiles (BMBT)

Smartphone Application Development Guide for BatteryMole Bluetooth Battery Monitoring System for Automobiles (BMBT) Smartphone Application Development Guide for BatteryMole Bluetooth Battery Monitoring System for Automobiles (BMBT) 4 Peaks Technology LLC. Revision 1.1 05/01/2016 Page 1 of 26 Revision History Revision

More information

1117RX Series - 8 & 16 Zone Wireless 868MHz Radio Duress/Panic Alarm System For Bank Santander Branches

1117RX Series - 8 & 16 Zone Wireless 868MHz Radio Duress/Panic Alarm System For Bank Santander Branches 1117/1150 8 & 16 zone Santander instructions - Nov 2013 1117RX Series - 8 & 16 Zone Wireless 868MHz Radio Duress/Panic Alarm System For Bank Santander Branches Installation & User Manual 1117RX System

More information

Added password for IP setup page : Password must be in IP format!

Added password for IP setup page : Password must be in IP format! NETWORK POWER MONITOR Release : 21 August 2014 Hardware Version : Version 7 Firmware version 1.00 PC Application Software : Version (latest)...2 Added password for IP setup page : Password must be in IP

More information

SmartDial. Wireless. User Manual. -en_gb language A004. Document in original

SmartDial. Wireless. User Manual. -en_gb language A004. Document in original Wireless Document in original -en_gb language 2017-03-20 A004 Contents 1 Declaration of Conformity... 1 2 Product description... 3 3 Guidelines for installation... 4 4 Operation... 5 5 Interface Description...

More information

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor A1UL PERS Personal Emergency Response System TABLE OF CONTENTS 1. READ THIS FIRST... 1 2. SYSTEM OVERVIEW.. 1 3. COMPONENTS 2 4. UNIT OPERATION! Standby Mode.. 3! Emergency Activation. 3! Answering Incoming

More information

MAMI MULTI BASE STATION

MAMI MULTI BASE STATION MAMI MULTI BASE STATION INSTALLATION MANUAL SOFTWARE VER. S3C23 MAMI MANUFACTURING AND MINOR INVENTIONS TERRACE ROAD EDENVALE P.O. BOX 2699, EDENVALE, 6 TEL: +27 452 4737 FAX: +27 452 4738 { { { M.A.M.I.

More information

1126 Series Ceiling Mount PIR Motion Detector

1126 Series Ceiling Mount PIR Motion Detector Installation Sheet 1126 Series Ceiling Mount PIR Motion Detector Description The 1126 Series PIR (Passive Infrared) Motion Detectors are a compact wireless PIR. The 1126 Series offer 360, Wide Angle, or

More information

Modbus TCP/IP Option Instruction Manual

Modbus TCP/IP Option Instruction Manual W A L C H E M An Iwaki America Company WebMaster Modbus TCP/IP Option Web Master WIND Modbus TCP/IP Option Instruction Manual s825v008 and higher Five Boynton Road Hopping Brook Park Holliston, MA 01746

More information

CU-IQ MANUAL 1. DESCRIPTION Radio Control Panel CU-IQ

CU-IQ MANUAL 1. DESCRIPTION Radio Control Panel CU-IQ 1. DESCRIPTI CU-IQ MANUAL The small control panel CU-IQ is one component of the new ICAS IQ wireless system. IQ System is an intelligent radio system, which works at 868 MHz frequency band. The IQ System

More information

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008 TCD Telemetry Communications Device Installation Guide Interface for the Emizon managed network Issue 1: February 2008 This guide sets out a simple check list together with a step-by-step guide to the

More information

Options Specification

Options Specification 1 Available Monitoring Options Options Specification Contents 1. Options Table... 2 2. Advanced MPEG Monitoring... 3 1.1 First Priorities... 3 1.2 Second Priorities... 4 1.3 Third Priorities... 4 1.4 Conditional

More information

Consultant Specification AGILE Wireless Fire Detection System

Consultant Specification AGILE Wireless Fire Detection System Contents Scope of Work... 2 The EN54 Part 2 & 4 Fire System... 2 Standards... 2 Wireless Intelligent Photoelectric Smoke Detector Specification... 4 Wireless Intelligent Thermal Heat Detector Specification...

More information

ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet

ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet ATS1235 Advanced Wireless DGP on 868 MHz AM Installation Sheet EN 1 2 1 3 2 4 1 5 12V 6 2 0V D+ D- CON3 7 CON1 ON 3 1 2 3 4 1234 8 3 4 1 0 ON 1 2 3 4 METAL METAL Address 1 1 0 ON 1 2 3 4 Address 2 2011

More information

Smart Wireless Sensor

Smart Wireless Sensor Smart Wireless Sensor G7 G7 creates the IoT platform of sensor data exchange and integration 64 wireless sensors each station * temperature, humidity, analog sensors, or digital alarm Windows / ios / Android

More information

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL ap15_2manual04/22/13 Page 1 4/22/2013 1 Serial Number : Option: OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL Micro Seven, Inc. 1095-K N.E. 25th Hillsboro, OR 97124 U.S.A. phone: 503-693-6982

More information

SYSTEM ENHANCEMENT MODULE

SYSTEM ENHANCEMENT MODULE SYSTEM ENHANCEMENT MODULE DSC PowerSeries INSTALLATION GUIDE INSTALL WIZARD AVAILABLE AT ALARM.COM/SEMPOWERSERIES OVERVIEW The System Enhancement Module (SEM) can be used with DSC PowerSeries PC1616, PC1832,

More information

Fratech Multipath-IP

Fratech Multipath-IP Rev 2.0 (May 2013) Installer Manual 1 Current Part Numbers: Fratech Multipath-IP E-Link STU PCB & Accessory Kit only In Metal Enclosure with Power Supply 998325-PK 998325-XS Installer Manual This document

More information

FlameGard 5 MSIR HART

FlameGard 5 MSIR HART FlameGard 5 MSIR HART Multi-Spectral Infrared Flame Detector HART Communication with the FlameGard 5 Multi-spectral Infrared Detector The information and technical data disclosed in this document may be

More information

ST325. Thermostat. The ST325TX can be used with any of these receivers RXBC605 RXST625 RXRT505 RXVBC605 RXWBC MHz

ST325. Thermostat. The ST325TX can be used with any of these receivers RXBC605 RXST625 RXRT505 RXVBC605 RXWBC MHz ST325TX Manual Version 008_Layout 1 16/05/2013 09:02 Page 1 ST32 ST S T325 32 25 5TX TX ST3 T3 325T 32 25TX ST T3 325 25TX ST S T32 25T TX TX ST325TX Digital Room ST325 T3 5 5TX T X Thermostat RXBC605

More information

DD15 Interface Module Product Guide

DD15 Interface Module Product Guide DD15 Interface Module Product Guide Table of Contents Table of Contents... Page 1 Overview and General Concept... Page 2 Features... Page 2 Specifications... Page 3 System Overview... Page 4 Deep Mesh

More information

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices. FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001

More information

POP_ Smoke Detector

POP_ Smoke Detector POP_004308 Smoke Detector Firmware Version : 1.0 Quick Start S This device is a wireless Z-Wave sensor. Exclusion, Inclusion are confirmed by hitting the programm button for 1 sec when the sensor is removed

More information

DTSX200 Communications(Modbus) Guide

DTSX200 Communications(Modbus) Guide User s Manual DTSX200 Communications(Modbus) Guide 4th Edition Blank Page < Introduction > i Introduction About this Manual Thank you for purchasing the DTSX200 Distributed Temperature Sensor. This document

More information

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements INDEX 1 NETIC... 2 2 Door/Window detector MINI... 2 3 FOUR sensor... 3 4 Smoke detector... 3 5 Flood detector... 4 6 ILLumination sensor... 4 7 Lamp holder... 5 8 Siren... 5 9 Power meter & switch... 6

More information

DeLaval activity meter system Instruction Book

DeLaval activity meter system Instruction Book Instruction Book 87224201 2014-02-17, Version 4 Original instruction Table of contents EC Declaration of Conformity -... 5 Safety precautions... 7 DeLaval activity meter AM2 DeLaval activity receiver

More information

The Leading Enterprise Internet of Things Solution. Wireless 0-20 ma Current Meters. General Description. Features of Monnit ALTA Sensors

The Leading Enterprise Internet of Things Solution. Wireless 0-20 ma Current Meters. General Description. Features of Monnit ALTA Sensors Wireless 0-20 ma Current Meters by The Leading Enterprise Internet of Things Solution General Description The ALTA Wireless 0-20 ma Current Meter is capable of measuring the current off another device

More information

POP_ Smoke Detector

POP_ Smoke Detector POP_004308 Smoke Detector Firmware Version : 1.0 Quick Start S This device is a wireless Z-Wave sensor. Exclusion, Inclusion are confirmed by hitting the programm button for 1 sec when the sensor is removed

More information

Ei600ZW Z-Wave Module for 10 Year Smoke Sensor with Siren

Ei600ZW Z-Wave Module for 10 Year Smoke Sensor with Siren Ei600ZW Z-Wave Module for 10 Year Smoke Sensor with Siren Quick Start This device is a combination of a Z-Wave sensor (smoke sensor) and a Z-Wave actuator. Pressing the button 'Inclusion Button' for one

More information

installation & operation manual

installation & operation manual installation & operation manual TABLE OF CONTENTS INTRODUCTION... 2 FEATURES... 2 PROGRAMMING CONTACT ID... 3 INSTALLATION... 3 OPENING THE HAWK COVER... 3 POWER SUPPLY... 5 CHECK AC... 5 DRY CONTACTS

More information

80 CHANNELS WIRELESS RECEIVER WITH LCD DISPLAY M1.1.1-Hx.x-F1.1-ENG [AN] [SPV] MADE IN ITALY INSTALLATION AND USE MANUAL

80 CHANNELS WIRELESS RECEIVER WITH LCD DISPLAY M1.1.1-Hx.x-F1.1-ENG [AN] [SPV] MADE IN ITALY INSTALLATION AND USE MANUAL RX808-LCD 80 CHANNELS WIRELESS RECEIVER WITH LCD DISPLAY 14.12-M1.1.1-Hx.x-F1.1-ENG [AN] [SPV] MADE IN ITALY INSTALLATION AND USE MANUAL WARNINGS Installation: This device must be installed only by qualified

More information

Be prepared for Sigfox RF & Protocol Tests

Be prepared for Sigfox RF & Protocol Tests Version 3.8.0 September 14, 2018 Be prepared for Sigfox RF & Protocol Tests Public Use Note: Only the last version of this document available on the Sigfox web sites is official and applicable. This document

More information

The WAVE Plus Instant Notification System for Schools and Colleges

The WAVE Plus Instant Notification System for Schools and Colleges Instant Notification System for Schools and Colleges Duress alarm has been activated in the School of Engineering! Schools strive to provide a safe environment for students and teachers. In an emergency,

More information

Wireless Call Point ( )

Wireless Call Point ( ) Wireless Call Point (100-821) INSTALLATION MANUAL Wireless Call Point Installation Manual Rev2.1 TABLE OF CONTENTS 1. Introduction... 2 FEATURES:...2 2. Normal Operation... 3 3. LED Indicator...3 4. Physical

More information

Wireless Internal Siren System Installation Guide

Wireless Internal Siren System Installation Guide Wireless Internal Siren System Installation Guide FW-VESTA -8/9F FW-SIREN2CP -8/9F P/N 7101958 July 2010 Copyright Crow Engineering Ltd. 2008 The copyright of this document is owned by Crow Engineering

More information

Operation Guide DQR-100U

Operation Guide DQR-100U MA040-EB Operation Guide DQR-00U A C B C/ F ON 5 OFF ALM ON OFF ALM C/ F 7 4 3 9 8 0 6 A sticker is affixed to the glass of this clock when you purchase it. Be sure to remove the sticker before using the

More information

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

Dec Wirsbo CoSy Radio. Installation and Operating Instructions Dec. 2002 Wirsbo CoSy Radio Installation and Operating Instructions Contents 1. Overview... 3 2. Room thermostat... 3 2.1 Thermostat models... 3 2.2 Function... 4 2.3 Positioning... 4 2.4 Setting and limiting

More information

SRT321 User and Installation Instructions

SRT321 User and Installation Instructions SRT321 User and Installation Instructions Electronic Room Thermostat & Temperature Sensor (Tx) - Z-Wave 1 2 The SRT321 is a wireless electronic battery powered room thermostat that uses interoperable two-way

More information

MEDI-MINDER USER MANUAL

MEDI-MINDER USER MANUAL MEDI-MINDER USER MANUAL TABLE OF CONTENTS TABLE OF CONTENTS... 1 INTRODUCTION... 1 SMARTLINK FEATURES... 2 USING SMARTLINK... 3 SPECIAL FUNCTIONS... 5 DISPLAYS AND WARNINGS... 6 SPECIFICATIONS... 7 INTRODUCTION

More information

RS485 MODBUS Module 8AI

RS485 MODBUS Module 8AI Version 1.4 15/04/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have

More information

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved. status 2016 Chuango. All Rights Reserved. Printed in China PA : AW1-UM-EN-V1.0 AW1 WiFi Alarm System User Manual Foreword Contents Congratulations on your purchase of the AW1 Alarm system. Before you commence

More information

FW-SIREN2EXT -8/9F FW-SIREN2CP -8/9F

FW-SIREN2EXT -8/9F FW-SIREN2CP -8/9F Wireless Siren System Installation Guide FW-SIREN2EXT -8/9F FW-SIREN2CP -8/9F P/N 7101866 Rev. 04 Jan 2010 Copyright Crow Engineering Ltd. 2008 The copyright of this document is owned by Crow Engineering

More information

IC60 Sintony 60 Intrusion Control Panel

IC60 Sintony 60 Intrusion Control Panel IC60 Sintony 60 Intrusion Control Panel for home and small businesses Multifunctional intrusion control panel for highest requirements Outstanding modern design Wired or/and wireless peripherals connectable

More information

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App Heating is great when you control it. USER MANUAL Wireless Programmable Room Thermostat Model No.: LS99111010 Scan for App Contents 1. Overview... 01 2. System Installation... 02 2.1 Install and Wiring

More information

SMOKE User Manual. NE v2.0

SMOKE User Manual. NE v2.0 SMOKE User Manual NE41 06004-02 v2.0 1 2 3 Contents in an SMOKE kit The list below shows the included parts in the package. If any part is missing or is defect, please kontakt your reseller or distributor.

More information

FieldServer Driver - Serial FS McQuay Microtech Open Protocol

FieldServer Driver - Serial FS McQuay Microtech Open Protocol Description FieldServer Driver - Serial FS-8700-80 McQuay Microtech Open Protocol This is an active client protocol. The driver is capable of acting as a master or slave. As a master, the Fieldserver polls

More information

WatchDog Wireless Crop Monitor Operation Manual

WatchDog Wireless Crop Monitor Operation Manual WatchDog Wireless Crop Monitor Operation Manual Spectrum Technologies, Inc. CONTENTS General Overview 3 Accessories 4 System Configuration 5 Configuring the Monitoring Unit 7 Powering Up the Unit 7 LED

More information

Panel XT210/610/ Description. Supervised Wireless Technology

Panel XT210/610/ Description. Supervised Wireless Technology P r o d u c t S p e c i f i c a t i o n s S h e e t Doc. - Ref. 220-XT Version : June 2013 Description The XT control panel is a Videofied wireless, battery operated, hybrid alarm system that is designed

More information

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect connect The TE-4500 is a temperature and relative humidity data logger that plugs directly into a network point and communicates across a LAN. The logger can be managed as a standalone logger, in conjunction

More information

Sentrol. ShatterPoint Glassbreak Sensor. Installation Instructions DESCRIPTION. Models (3 Volt) (6 Volt) STEP 1 MOUNTING

Sentrol. ShatterPoint Glassbreak Sensor. Installation Instructions DESCRIPTION. Models (3 Volt) (6 Volt) STEP 1 MOUNTING DESCRIPTION The 5600 Glassbreak Sensors are designed to detect breaking glass caused by forced entry into a protected window or door. The Tru-Dual transducer design provides excellent false-alarm immunity

More information

SHEPHERD. Smart solutions to protect and manage what matters the most to you

SHEPHERD. Smart solutions to protect and manage what matters the most to you SHEPHERD Smart solutions to protect and manage what matters the most to you Security Shepherd Gateway & Keypad, Repeater, PIR Detectors, PIR Camera, Magnet, Glass Break, Siren 1-10 Safety & Air Quality

More information

EW 40 Wireless Fan Control

EW 40 Wireless Fan Control Installation & Operating Manual EW 40 Wireless Fan Control USA CAN Product Information... Chapters 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

Model: RT310i. Smartphone Controlled Thermostat. Installation Manual

Model: RT310i. Smartphone Controlled Thermostat. Installation Manual Model: RT310i Smartphone Controlled Thermostat Installation Manual Contents Product Compliance... 3 Safety Information... 3 Introduction... 4 Overview... 5 Box contents... 5 Features... 5 Connecting the

More information

RF-KNX / TP-KNX MEDIA COUPLER CO KNX 002

RF-KNX / TP-KNX MEDIA COUPLER CO KNX 002 RF-KNX / TP-KNX MEDIA COUPLER CO KNX 002 INSTRUCTIONS MANUAL Tel.: +34 943627988 E-mail: knx@dinuy.com Web: www.dinuy.com 1 General Description RF-KNX / TP-KNX media coupler. Bidirectional Gateway between

More information

The Genesis. Wireless PIR System. Se t t i n g n e w s t a n d a r d s f o r P I R d e t e c t i o n. BS8418 Compliant

The Genesis. Wireless PIR System. Se t t i n g n e w s t a n d a r d s f o r P I R d e t e c t i o n. BS8418 Compliant Se t t i n g n e w s t a n d a r d s f o r P I R d e t e c t i o n The Genesis Wireless PIR System BS8418 Compliant S e t t i n g n e w s t a n The Genesis Wireless PIR System BS8418 compliant The GENESIS

More information

Product Recall Notification TX-4200 Wireless Personal Panic Device

Product Recall Notification TX-4200 Wireless Personal Panic Device Product Recall Notification TX-4200 Wireless Personal Panic Device October, 2016 Interlogix announces voluntary recall of TX-4200 Personal Panic devices Interlogix recently discovered an issue with a small

More information

DD205RF/TX Detector Installation Sheet

DD205RF/TX Detector Installation Sheet GE Security DD205RF/ Detector Installation Sheet EN DE EL ES FR IT NL PT RU TR 2009 GE Security, Inc. 1 of 28 P/N 1060783 REV 1.00 ISS 26FEB09 2 of 28 P/N 1060783 REV 1.00 ISS 26FEB09 EN: Installation

More information

Wireless Door Detector

Wireless Door Detector Wireless Door Detector V1.0.0 1 Table of Contents 1 Overview... 1 2 Device Installation... 3 3 Usage...7 Appendix 1 Technical Specifications... 8 Important Safeguards and Warnings Please read the following

More information

X64 Wireless Training

X64 Wireless Training X64 Wireless Training IDS Contents 1 Contents Features 3 Wireless Hardware 4 IDS & Duevi integration PCB 5 LED operation 5 Wireless Device Hardware setup 6 Location 260 7 LED Keypad Instructions 7 Adding

More information

SC-F3G User Manual 1.0

SC-F3G User Manual 1.0 SC-F3G User Manual 1.0 Table of Contents 1. Introduction... 3 2. Functions... 3 3. Features... 3 4. Package Contents... 3 5. Device Configuration... 4 6. Status LED signals... 5 7. Before You Start...

More information

Instruction Manual Water Sensor

Instruction Manual Water Sensor Instruction Manual Water Sensor Thank you for your support Please read the instruction manual carefully before operating Please keep the instruction manual for future reference Shenzhen NEO Electronics

More information

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features. Wireless Overview www.incitefire.com.au Overview Fundamentals FIREwave is a wireless based family of products which is fully integrated into Hochiki s renowned ESP intelligent hardwired system. This seamless

More information

FlameGard 5 UV/IR HART

FlameGard 5 UV/IR HART FlameGard 5 UV/IR HART HART Communication Manual The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized

More information

The Leading Enterprise Internet of Things Solution. Wireless Duct Temperature Sensors. General Description. Features of Monnit ALTA Sensors

The Leading Enterprise Internet of Things Solution. Wireless Duct Temperature Sensors. General Description. Features of Monnit ALTA Sensors by The Leading Enterprise Internet of Things Solution DUCT TEMPERATURE Wireless Duct Temperature Sensors General Description The ALTA Wireless Duct Temperature Sensor uses an NTC thermistor with 8 ft.

More information

Construction of Wireless Fire Alarm System Based on ZigBee Technology

Construction of Wireless Fire Alarm System Based on ZigBee Technology Available online at www.sciencedirect.com Procedia Engineering 11 (2011) 308 313 The 5 th Conference on Performance-based Fire and Fire Protection Engineering Construction of Wireless Fire Alarm System

More information

2 x CR123A Lithium batteries. White night-light LED. Blue alarm LED - also glows behind the lens. Ambient light sensor behind lens.

2 x CR123A Lithium batteries. White night-light LED. Blue alarm LED - also glows behind the lens. Ambient light sensor behind lens. 15m x 15m wide angle coverage Look down Creep Zone White LED motion activated night-light Adjustable Pulse Count Adjustable Range High R.F. and E.S.D. immunity High white light immunity SAWR stabilised

More information

ABAX two-way wireless system

ABAX two-way wireless system ABAX two-way wireless system www.satel.eu ABAX ABAX system diagram The diagram below shows components of the ABAX system, which includes: controller of ABAX wireless system, repeater of signal from ABAX

More information

ESD Product Information

ESD Product Information Energy Saving Device COPYRIGHT: Information in this document is subject to change without further notice. No part of this document may not be reproduced or transmitted in any form or by any means, electronic

More information

Z-Wave Network Inclusion/Exclusion/Reset

Z-Wave Network Inclusion/Exclusion/Reset This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network

More information

VTI MODEL itc5000 HEAT TRACING CONTROL SYSTEM OPERATIONS MANUAL

VTI MODEL itc5000 HEAT TRACING CONTROL SYSTEM OPERATIONS MANUAL VTI MODEL itc5000 HEAT TRACING CONTROL SYSTEM OPERATIONS MANUAL 1 Operations Manual for the VTI Model itc5000 Heat Tracing Control System Description The VTI Model itc5000 Heat Tracing Control System consists

More information

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick CAN OBD READER REFERENCE DESIGN KIT USER GUIDE 1. Standard ToolStick Handling Recommendations The ToolStick Base Adapter and daughter cards are distributed without any protective plastics. To prevent damage

More information

USER MANUAL FOR OPERATING SYSTEM

USER MANUAL FOR OPERATING SYSTEM P2262 ALARM PANEL USER MANUAL FOR OPERATING SYSTEM 21765-07 September 1999 Associated Controls (Aust) PTY. LTD. 29 Smith Street, Hillsdale, NSW, 2036. PH (02) 9311 3255, FAX (02) 9311 3779 Page 1 of 177

More information

LA5579 Wireless Siren Operation Manual

LA5579 Wireless Siren Operation Manual LA5579 Wireless Siren Operation Manual Introduction The Wireless Siren is based on advanced wireless technology using in home automation system, between the Wireless Siren and Control Panel communicated

More information

The Leading Enterprise Internet of Things Solution. Wireless Thermocouple Sensors. Features of Monnit ALTA Sensors. General Description

The Leading Enterprise Internet of Things Solution. Wireless Thermocouple Sensors. Features of Monnit ALTA Sensors. General Description Wireless Thermocouple Sensors by The Leading Enterprise Internet of Things Solution General Description The ALTA Wireless Thermocouple Sensor is available with a hardwired thermocouple or K-type connector

More information

Open Source Home Security System

Open Source Home Security System Open Source Home Security System Final Report ECE 410: Senior Project By: Allen Chu March 28, 2012 Project Advisor: Dr. John Ventura, PE Table of Contents Title 1 Table of Contents 2 1. Abstract 3 2. Customer

More information

>WIRELESS> ALARM SYSTEM CR200

>WIRELESS> ALARM SYSTEM CR200 intrusion >WIRELESS> ALARM SYSTEM CR200 INTRUSION HOME SECURITY CR200 is a Modern, Effective and Versatile 20-zone Household Security System. It is packed with simple Plug & Play functionality, designed

More information

PERMACONN PM1030 Includes DI300. Installation Manual

PERMACONN PM1030 Includes DI300. Installation Manual PERMACONN PM1030 Includes DI300 Installation Manual Radio Data Comms Unit 5/20-30 Stubbs Street Silverwater NSW 2128 Telephone: 02 9352 1777 Facsimile: 02 9352 1700 Introduction The PERMACONN system provides

More information

RAy SNMP. Application notes.

RAy SNMP. Application notes. Application notes. RAy SNMP. version 1.0 12/29/2017 RACOM s.r.o. Mirova1283 59231 Nove MestonaMorave CzechRepublic Tel.: +420565659 511 Fax: +420565659 512 E-mail: racom@racom.eu www.racom.eu Table of

More information

PROGRAMMABLE 7-DAY RF THERMOSTAT

PROGRAMMABLE 7-DAY RF THERMOSTAT PROGRAMMABLE 7-DAY RF THERMOSTAT Installation and user instruction This instructions to be retained by the user 1 Thank you for choosing Beretta s radio frequency (RF) Radiostat. This central heating control

More information

Jon Longtin Department of Mechanical Engineering SUNY Stony Brook

Jon Longtin Department of Mechanical Engineering SUNY Stony Brook Jon Longtin Department of Mechanical Engineering SUNY Stony Brook Jon Longtin Department of Mechanical Engineering SUNY Stony Brook jlongtin@ms.cc.sunysb.edu 631 632-1110 Overview The Neglected Gas Meter

More information

Fratech Multipath-IP STU

Fratech Multipath-IP STU Rev 2.41 (September 2008) Installer Manual 1 Fratech Multipath-IP STU P/Nos: Single SIM: 998304OPT/998304TEL Dual SIM: 998307OPT/998307TEL Installer Manual This document contains a product overview, specifications

More information

PHILIO TECHNOLOGY CORPORATION

PHILIO TECHNOLOGY CORPORATION PST02-XA 4in Multi Sensor The Z-Wave 500 Series Module adopted Farther Range, Faster, Smarter, Thin, Small And Multi Functions Fits Your Home Decoration Style Extremely low power consumption Long Battery

More information

Description Supervised Wireless Technology PRODUCT SPECIFICATION SHEET

Description Supervised Wireless Technology PRODUCT SPECIFICATION SHEET PRODUCT SPECIFICATION SHEET Made by RSI VIDEO TECHNOLOGIES 2200-XLSP February 2012 Description is a Videofied wireless, battery operated security system. The control panel is designed for residential and

More information

IM20-ZWAVE Magnetic Contact User Guide

IM20-ZWAVE Magnetic Contact User Guide IM20-ZWAVE Magnetic Contact User Guide I. Introduction The product is a kind of wireless door/window detector, using Z-wave 500 series chip, it adopts unique structure design, suitable for all kinds of

More information

600 Range Dialer Installation Manual. Version 1.0

600 Range Dialer Installation Manual. Version 1.0 600 Range Dialer Installation Manual Version 1.0 The information contained is supplied without liability for any errors or omissions. No part may be reproduced or used except as authorised by contract

More information

CBI-064. User Manual. Caddx to KNX-BUS Interface

CBI-064. User Manual. Caddx to KNX-BUS Interface CBI-064 Caddx to KNX-BUS Interface User Manual GDS Intelligence in Buildings El. Venizelou 116 Nea Erithrea 14671 Tel: +30 2108071288 Email: info@gds.com.gr Web: gds.com.gr Contents 1 Device Description...

More information

T4000 Security Communicator

T4000 Security Communicator Inner Range T4000 Security Communicator 1 T4000 Security Communicator by Inner Range P/N: 998530 / 998530NZ 998530LT (Lite Version) Installation & Operation Manual. Rev: 1.5 Inner Range Pty. Ltd. www.innerrange.com

More information

10 Year Smoke Detector and Siren

10 Year Smoke Detector and Siren 10 Year Smoke Detector and Siren SKU: POPE009402 Quickstart This is a secure Alarm Sensor for Europe. To run this device please insert fresh 1 * LS14250 batteries. Please make sure the internal battery

More information

System Guide.

System Guide. System Guide www.energenie4u.co.uk Contents MiHome System Overview System Set Up MiHome App Gateway Hand Controller Mains Power Range Smart Plug Monitor Smart Plug+ Whole House Monitor Socket Relay Multiplug

More information