Annex to: IECEx ULD U Issue. No. 2 Manufacturer: Detector Electronics Corporation Electrical apparatus: Eagle Quantum Premier system Modules

Size: px
Start display at page:

Download "Annex to: IECEx ULD U Issue. No. 2 Manufacturer: Detector Electronics Corporation Electrical apparatus: Eagle Quantum Premier system Modules"

Transcription

1 Description of EQ3XXXabcd (Controller): The Controller, Model EQ3XXX, performs all communication, command and control functions for the Eagle Quantum Premier System. The Controller supports both static and programmable logic. Among the features included in the Controller are 8 programmable unsupervised inputs, 8 unsupervised relay outputs, an RS-485 Modbus slave communication interface and an optional ControlNet communication board. The module is housed in a cast aluminium enclosure with optional DIN-rail mount or panel mount configurations. The Controller EQ3XXX can be connected to the following Field Devices: PIRECL IR Gas Detector, OPECL Open Path Gas Detector, X3301/X3302 Multi-spectrum Flame Detector, X2200 UV Flame Detector, X5200 UV/IR Flame Detector, X9800 IR Flame Detector, C7050 UV Flame Detector, EQ22XXDCU, EQ22XXDCUEX, EQ22XXIDC, EQ22XXIDCGF, EQ22XXIDCSC, EQ24XXNE, EQ24XXPLR, EQ25XXARM, EQ25XXSAM, EQ3700DCIO, EQ3710AIM, EQ3720RM, EQ3730EDIO, EQ3740IPM & EQ3750ASH. Description of EQ3700ab (DCIO): The (8 channel) Discrete Input/Output Module, Model EQ3700 DCIO, consists of 8 individually configured (wired as Input or Output) channels. Wiring supervision includes none, open circuits, and open and short circuits. In addition to defining the type of supervision, an input channel is also configured to generate the appropriate static logic alarm message to the controller. Heat, smoke, or unitised flame detectors can be wired into channels defined as inputs. Horns, strobes, beacons and solenoids can be wired into channels defined as outputs. The module is housed in a cast aluminium enclosure with optional DIN-rail mount or panel mount configurations. Description of EQ3710ab (AIM): The Analog Input Module, Model EQ3710 AIM, is an 8-channel microprocessor based module providing 4-20mA analog input. Each channel on the module has LED status indicators for both active and fault conditions. The module is housed in a cast aluminium enclosure with optional DIN-rail mount or panel mount configurations. Description of EQ3720ab (RM): The Relay Module, Model EQ3720 RM is an 8-channel microprocessor based module providing unsupervised relay contact operation. Each output point is intended for dry contact output operation. The relays can be wired for normally open or normally closed contacts and can be configured for a normally energized or de-energized relay coil. In addition, the module can be configured for hold last state, active or inactive after LON communications have been lost for more than one minute. The module is housed in a cast aluminium enclosure with optional DIN-rail mount or panel mount configurations. Description of EQ3730ab (EDIO): The Enhanced Discrete Input/Output Module, Model EQ3730 EDIO, provides 8 channels of configurable input or output points for the Eagle Quantum Premier System. These input and output points can be programmed for supervised or unsupervised operation. Each input point can accept fire detection devices. Each output point can be configured for signalling or releasing output operation. Each channel on the module is provided with individual indicators for active and fault conditions. The module is housed in a cast aluminium enclosure with optional DIN-rail mount or panel mount configurations. Description of EQ3740ab (IPM): The Intelligent Protection Module, Model EQ3740 IPM, is an 8-channel microprocessor based module that can be configured for supervised or unsupervised input/output operation. Each channel on the module has LED status indicators for both active and fault conditions. The module is housed in a cast aluminium enclosure with optional DIN-rail mount or panel mount configurations. Description of EQ3750ab (ASH): The Addressable Smoke and Heat Module, Model EQ3750 ASH expand the Eagle Quantum Premier System and provide power and communications to 64 addressable devices such as flame, gas, smoke and heat detectors. Description of EQ3800/EQ3810ab (PDM): The Power Distribution Module, Model EQ3800/EQ3810, integrates isolation, conditioning, monitoring and distribution to outputs that power thecontroller, cabinet devices and field devices. It is used to provide continuous power to the outputs by relying on two independent input power sources (one line power source and one backed up power source). Description of EQ2220 (GFM): The Ground Fault Monitor (GFM), model EQ2220 provides ground fault monitoring in a system. The GFM consists of an electronic circuit where the output is a contact closure in the presence of a ground fault. The GFM has three LED s used to provide a visual indication of device status. The GFM is intended for mounting in the same protective enclosure as the gas detection system controller. Description of Lon Termination Module (LTM): The LON Termination Module (LTM), Model Number , consists of an RC circuit that is to act as interface between LON and EQP Controller. The LTM is intended for mounting in the same protective enclosure as the gas detection system controller. Page 1 of 5

2 Description of Hart Interface Module (HIM): The HART Interface Module (HIM), Model Nr , consists of an RC circuit that is to be connected only to the EQ3710 Analog Input Module. This interface module provides additional impedance to meet HART Interface specifications. The HIM is intended for mounting in the same protective enclosure as the gas detection system controller. Nomenclature for EQ3XXXabcd (Controller), where: X) description 001 Controller 246 NODES 005 Controller 246 NODES, (Customer specific configuration) 016 Controller 16 NODES 150 Controller 150 NODES a) mounting b) COM board 1 C ControlNet c) COM board 2 S Serial Port Expansion d) approval agency* A FM/CSA C CSA E ATEX/CE F FM R Russian S SIL T SIL/FM/CSA/ATEX/CE T-C T Plus US Coast Guard W-C W Plus US Coast Guard 2. Refer to drawing No for details. Nomenclature for type EQ3700ab (DCIO), : A FM/CSA 2. Refer to drawing No for details. Nomenclature for type EQ3730ab (EDIO): T SIL/FM/CSA/ATEX/CE 2. Refer to drawing No for details. Page 2 of 5

3 Nomenclature for type EQ3750ab (ASH): b) Approval agency W FM*/CSA*/ATEX*/CE*/IECEx 2. Refer to drawing No for details. Nomenclature for type EQ3800/EQ3810ab (PDM): 2. Refer to drawing No for details. Nomenclature for type EQ3710ab (AIM), EQ3720ab (RM), EQ3740ab (IPM) and, where: 2. Refer to drawing No , and for details. For the EQ2220, Ground Fault Monitor (GFM), the LON Termination Module (LTM) Nr and the HART Interface Module (HIM) Nr , no nomenclature is defined. Temperature range: The relation between EQP Module, ambient temperature range and maximum component temperature is as follows: Module Ambient temperature range Maximum component temperature EQ3XXX Controller -40 C to +85 C 130 C EQ3700 DCIO -40 C to +85 C 130 C EQ3710 AIM -40 C to +85 C 130 C EQ3720 RM -40 C to +60 C 130 C EQ3730 EDIO -40 C to +85 C 130 C EQ3740 IPM -40 C to +85 C 130 C EQ3750 ASH -40 C to +85 C 130 C EQ3800 PDM -40 C to +80 C 195 C EQ3810 PDM -40 C to +80 C 195 C EQ2220 GFM -40 C to +85 C 130 C Nr LTM -40 C to +85 C 130 C Nr HIM -40 C to +85 C 130 C Page 3 of 5

4 Electrical data EQ3XXX, Controller Rated power W max. EQ3700, Discrete Input/Output Module (DCIO) Rated voltage Vdc Rated current......max. 2A per channel, max. 10.4A per unit EQ3710, Analog Input Module (AIM) Rated voltage Vdc Rated current... max. 0.9A per channel, max. 7.4A per unit EQ3720, Relay Module (RM) Rated power......max. 2A per channel, max. 10.4A per unit EQ3730, Enhanced Discrete Input/Output Module (EDIO) Rated voltage Vdc Rated current......max. 2A per channel, max. 10.4A per unit EQ3740, Intelligent Protection Module (IPM) Rated power......max. 2A per channel, max. 6.2A per unit EQ3750, Addressable Smoke and Heat Module (ASH) Input current ma max Loop current ma max EQ3800/EQ3810, Power Distribution Module (PDM) Rated voltage Vdc Rated current... 10A max. per input EQ2220, Ground Fault Monitor (GFM) Output relay contact rating...30 Vdc, 1 A max. LON Termination Module (LTM), Nr HART Interface Module (HIM), Nr Installation instructions: For ambient temperatures below 10 C and above +60 C use field wiring suitable for both minimum and maximum ambient temperature. Mounting instructions All wiring connected to the above mentioned EQP modules shall be fixed installed. Routine tests: All above mentioned EQP modules (except the EQ2220 GFM, LON Termination Module (LTM), Nr and HART Interface Module (HIM), Nr ) shall be tested with a dielectric strength test at 500 Vrms, during 1 minute, in accordance with IEC , clause Page 4 of 5

5 Ex coding: EQ3XXX: Ex nc IIC, Tamb. -40 C to +85 C EQ3700 (DCIO): Ex na nl nc IIC, Tamb. -40 C to +85 C EQ3710 (AIM): Ex na nl nc IIC, Tamb. -40 C to +85 C EQ3720 (RM): Ex na nl nc IIC, Tamb. -40 C to +60 C EQ3730 (EDIO): Ex na nl nc IIC, Tamb. -40 C to +85 C EQ3740 (IPM): Ex na nl nc IIC, Tamb. -40 C to +85 C EQ3750 (ASH): Ex na nl nc IIC, Tamb. -40 C to +85 C EQ3800 (PDM): Ex na II, Tamb. -40 C to +80 C EQ3810 (PDM): Ex na II, Tamb. -40 C to +80 C EQ2220 (GFM): Ex nc IIC, Tamb. -40 C to +85 C LON Termination Module (LTM): Ex na II, Tamb. -40 C to +85 C HART Interface Module (HIM): Ex na II, Tamb. -40 C to +85 C Schedule of limitations: The controller and modules shall be used in an area of no more than pollution degree 2 conform IEC , and in an enclosure that complies with all relevant requirements of IEC , rated at least IP54, and be connected to supply circuits where the rated voltage cannot be exceeded by 40% caused by transient disturbances. The controller and modules may only be installed, connected or removed when the area is known to be non-hazardous. The maximum surface temperature inside the controller and modules does not exceed 130 C (except for EQ3800/EQ3810, PDM, which does not exceed 195 C). For ambient temperatures above 60 C conductors suitable for at least 20 C above the ambient temperature must be used. Documents: Project record 10CA19739 (Hazardous Locations testing) Description: Drawing No.: Rev. Level: Date: Dwg. design reference EQ3XXX Controller DEMKO K (18 pages) Drw. design reference EQ3700 DCIO DEMKO F Drw. design reference EQ3710 AIM DEMKO D (4 pages) Drw. design reference EQ3720 Relay Module DEMKO C Dwg design reference EQ3730 EDIO DEMKO E Dwg design reference EQ3740 IPM DEMKO C (4 pages) Dwg design reference EQ3750 ASH DEMKO B (5 pages) Dwg design reference EQ3800/EQ3810 PDM DEMKO D (3 pages) Dwg design reference EQ2220 GFM DEMKO B Dwg design reference LTM, Redundant, EQP DEMKO B Dwg design reference HIM DEMKO B Instruction Manual for EQ3800/EQ3810 PDM Instruction Manual for EQP System Installation Manual for EQ3750ASH Page 5 of 5

Instructions. Eagle Quantum Premier Fire and Gas Alarm Control System and Automatic Releasing for Pre-Action and Deluge Systems

Instructions. Eagle Quantum Premier Fire and Gas Alarm Control System and Automatic Releasing for Pre-Action and Deluge Systems Instructions Eagle Quantum Premier Fire and Gas Alarm Control System and Automatic Releasing for Pre-Action and Deluge Systems Rev: 12/16 95-8533 Table of Contents Section 1 - Safety ALERT MESSAGES...

More information

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES DET-TRONICS SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION Eagle Quantum Premier is a configurable, distributed, intelligent safety system providing flame

More information

INSTRUCTIONS. Eagle Quantum Premier (EQP) Addressable Smoke & Heat (ASH) Module EQ3750ASH. 5.1 Rev: 4/

INSTRUCTIONS. Eagle Quantum Premier (EQP) Addressable Smoke & Heat (ASH) Module EQ3750ASH. 5.1 Rev: 4/ INSTRUCTIONS Eagle Quantum Premier (EQP) Addressable Smoke & Heat (ASH) Module EQ3750ASH 5.1 Rev: 4/17 INSTRUCTIONS Eagle Quantum Premier (EQP) Addressable Smoke & Heat (ASH) Module EQ3750ASH DESCRIPTION

More information

Safety Manual. Eagle Quantum Premier SIL 2 Rated Fire & Gas System. 9.1 Rev: 9/

Safety Manual. Eagle Quantum Premier SIL 2 Rated Fire & Gas System. 9.1 Rev: 9/ Safety Manual Eagle Quantum Premier SIL 2 Rated Fire & Gas System Rev: 9/17 95-8599 Table of Contents INTRODUCTION...1 Quality Policy Statement...1 Scope...1 Document Structure...2 PRODUCT OVERVIEW...2

More information

Safety Manual. Eagle Quantum Premier SIL 2 Rated Fire & Gas System. 7.2 Rev: 8/

Safety Manual. Eagle Quantum Premier SIL 2 Rated Fire & Gas System. 7.2 Rev: 8/ Safety Manual Eagle Quantum Premier SIL 2 Rated Fire & Gas System 7.2 Rev: 8/15 95-8599 Table of Contents INTRODUCTION...1 Quality Policy Statement...1 Scope...1 Document Structure...2 PRODUCT OVERVIEW...2

More information

Instructions Det-Tronics Standard Gas Panel. 1.1 Rev: 10/

Instructions Det-Tronics Standard Gas Panel. 1.1 Rev: 10/ Instructions Det-Tronics Standard Gas Panel. Rev: 0/ Table Of Contents Description... Features AND BENEFITS.... Enclosure... SYSTEM COMPONENTS.... 3 Field Devices... 3 IMPORTANT SAFETY NOTES.... 4 Installation....

More information

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors SAFETY MANUAL X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors SAFETY-CERTIFIED Flame DETECTORs This manual addresses the specific requirements and recommendations applicable to the proper

More information

Engineering Guideline. pac- Carriers Type Universal

Engineering Guideline. pac- Carriers Type Universal Engineering Guideline pac- Carriers Type 9195 Universal Integration of conventional process automation interfaces pac- Carrier The pac- Carrier reflects the intention of R. STAHL to provide state-of-the-art

More information

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

SAFETY MANUAL. Multispectrum IR Flame Detector X3301 SAFETY MANUAL Multispectrum IR Flame Detector X3301 SAFETY-CERTIFIED MODEL X3301 MULTISPECTRUM INFRARED DETECTOR This manual addresses the specific requirements and recommendations applicable to the proper

More information

For Complete Fire and Gas Solutions

For Complete Fire and Gas Solutions Industrial Fire For Complete Fire and Gas Solutions 2 The Total Package What do you need from an integrated fire and gas system? In industrial fire and gas environments it s important to have a reliable

More information

On the job around the clock 24/7: Fire detection systems

On the job around the clock 24/7: Fire detection systems On the job around the clock 24/7: Fire detection systems Version 02.2010 Version: 02.2010 Product catalogue Fire detection systems This product catalogue is intended for sales purposes only. For planning,

More information

NGC-40 Advanced Heat-Tracing Control System

NGC-40 Advanced Heat-Tracing Control System NGC-40 Advanced Heat-Tracing Control System Local configuration and monitoring with Raychem Touch 1500 touch screen display Heat-tracing system NGC-40 system Remote configuration and monitoring with Raychem

More information

Instructions Infrared Hydrocarbon Gas Detector PointWatch Eclipse Model PIRECL /

Instructions Infrared Hydrocarbon Gas Detector PointWatch Eclipse Model PIRECL / Instructions 95-8526 Infrared Hydrocarbon Gas Detector PointWatch Eclipse Model PIRECL 11/06 95-8526 Table of Contents APPLICATION.............................. 1 OPERATION OVERVIEW.....................

More information

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering. System Overview F300K Compact Flame Scanner Sensors and systems for combustion engineering www.lamtec.de LAMTEC F300K Compact Flame Scanner Approvals. 0085 Gas Appliances Directive 2009/142/EC, CE0085

More information

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL SAFETY MANUAL PointWatch Eclipse Infrared Hydrocarbon Gas Detector SIL 2 Certified Model PIRECL Safety Certified Model PIRECL PointWatch Eclipse IR Gas Detector This manual addresses the specific requirements

More information

GETTING STARTED GUIDE NI Channel, 0 ma to 20 ma, 16-Bit Analog Output Module. This document explains how to connect to the NI 9265.

GETTING STARTED GUIDE NI Channel, 0 ma to 20 ma, 16-Bit Analog Output Module. This document explains how to connect to the NI 9265. GETTING STARTED GUIDE NI 9265 4-Channel, 0 ma to 20 ma, 16-Bit Analog Output Module This document explains how to connect to the NI 9265. Note Before you begin, complete the software and hardware installation

More information

Temperature Controllers

Temperature Controllers Model TEC-4100 1/4 DIN Model TEC-4100 1/4 DIN Temperature Controller Ordering Code: Power Input BOX 1 4 = 90-250 VAC 5 = 11-26 VAC / VDC TEC-4100- Configurable for 4 Programmable Outputs and NEMA 4X/IP65

More information

Model D12-IR. Digital Gas Transmitter...

Model D12-IR. Digital Gas Transmitter... Model D12-IR Digital Gas Transmitter... ATI s Series D12 gas transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The Raychem NGC-40 is a multipoint electronic

More information

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules Engineering Guideline pac-carriers Type 9195 SIEMENS ET-200M Fail-safe signal modules pac-carrier Type 9195 2 Engineering Guideline/SIEMENS 19.05.2015 pac-carrier Type 9195 Integration of conventional

More information

Fire and Gas Monitoring Panel ST7-HV

Fire and Gas Monitoring Panel ST7-HV Fire and Gas Monitoring Panel ST7-HV INTRODUCTION TO THE ST7-HV SYSTEM The ST7-HV system is a programmable PLC suitable for safety and security installations with a high technological and economic content

More information

COMPACT FLAME CONTROLLER CFC 1000

COMPACT FLAME CONTROLLER CFC 1000 COMPACT FLAME CONTROLLER CFC 1000 TECHNICAL DESCRIPTION EDITION: TB CFC1000- REV.6 2012-03-07 Important: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring

More information

Flame Detection Jon Sarfas

Flame Detection Jon Sarfas Flame Detection Jon Sarfas Agenda Introduction Detection Principles FL4000H MSIR Flame Detector Flame Test Lamp Installation Best Practice Features & Benefits Applications Introduction Primary objectives:

More information

Dräger Polytron 7000 Fixed gas detector

Dräger Polytron 7000 Fixed gas detector DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Dräger Polytron 7000 Fixed gas detector ST-3751-2003 The Dräger Polytron 7000 is a gas detector that can satisfy all toxic and

More information

INPUT / OUTPUT MINI MODULES

INPUT / OUTPUT MINI MODULES INPUT / OUTPUT MINI MODULES APPLICATION The Addressable Control and Monitor mini modules are the latest technology for a loop powered module. Installed on the same loop with other devices such as detectors

More information

Dependable Solutions for Gas Detection

Dependable Solutions for Gas Detection Dependable Solutions for Gas Detection Combustibles/Flammables Standard & Exotic Toxics Oxygen Enrichment/Deficiency Introduction to Sensidyne Established in 1983 - acquired by Schauenburg GmbH in April

More information

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100 GETTING STARTED GUIDE NI 9217 4 RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100 This document explains how to connect to the NI 9217. Note Before you begin, complete the software and hardware installation

More information

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM Local configuration and monitoring with Raychem Touch 1500 touch screen display PRODUCT OVERVIEW The nvent RAYCHEM NGC-40 is a multipoint

More information

Industrial Grade Gas Detection Detecting The Difference

Industrial Grade Gas Detection Detecting The Difference detcon inc. Industrial Grade Gas Detection Detecting The Difference PO Box 8067 The Woodlands, TX 77387 888-367-4286 (toll free) 713-559-9200 281-292-2860 (fax) sales@detcon.com Catalog #CB-0409 www.detcon.com

More information

Speed and Frequency Seite 1 von 7

Speed and Frequency Seite 1 von 7 Speed and Frequency Seite 1 von 7 E16 Systems for High Safety Speed ing, all with Triple Modular Redundancy. A choice of versions to meet various demands. Compliant with SIL3 / IEC 61508 and/or API 670.

More information

COMPACT FLAME CONTROLLER CFC 2000

COMPACT FLAME CONTROLLER CFC 2000 COMPACT FLAME CONTROLLER CFC 2000 TECHNICAL DESCRIPTION EDITION: TB_CFC2000_EN_REV09_20150408 Important: Please note, that all mounting and wiring as well as all changing or adjustment at the flame monitoring

More information

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION DET-TRONICS SPECIFICATION DATA Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION The EQ2200UVHT UV Flame Detector is used with the Eagle Quantum

More information

Instructions. Infrared Hydrocarbon Gas Detector PointWatch Eclipse Model PIRECL Rev: 3/

Instructions. Infrared Hydrocarbon Gas Detector PointWatch Eclipse Model PIRECL Rev: 3/ Instructions Infrared Hydrocarbon Gas Detector PointWatch Eclipse Model PIRECL 19.2 Rev: 3/17 95-8526 Table of Contents APPLICATION... 1 OPERATION OVERVIEW... 1 Theory of Operation.... 1 Detectable Gases...

More information

GETTING STARTED GUIDE NI DIO, 5 V/TTL, Bidirectional, 7 μs

GETTING STARTED GUIDE NI DIO, 5 V/TTL, Bidirectional, 7 μs GETTING STARTED GUIDE NI 9403 32 DIO, 5 V/TTL, Bidirectional, 7 μs This document explains how to connect to the NI 9403. Note Before you begin, complete the software and hardware installation procedures

More information

Dräger Flame 2100 Flame Detection

Dräger Flame 2100 Flame Detection Dräger Flame 2100 Flame Detection Working in areas with combustible gases, vapors, or materials requires fire/ flame detection as a life-saving necessity. The best solutions must combine state-of-the-art

More information

SenSmart Universal Gas Detector Series

SenSmart Universal Gas Detector Series SenSmart Universal Gas Detector Series Installation Guide Flammable & Toxic Gas Detectors Smart Alarm Controllers Fire & Gas System Engineering Technical Service & Support Warning: Read & understand contents

More information

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance IR4000 Point Infrared Combustible Gas Detection System The Reliable and Flexible Safety Solution That s Low Maintenance Multi-Point Gas Detection That s Fast Set-Up, Low Maintenance, Cost-Effective The

More information

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ Operating Instructions RTK Instruments Limited PEX7250 Explosion Proof Annunciator Introduction This manual provides the information necessary to install, connect, test and maintain the PEX7250 Explosion

More information

EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings

EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings Key Features Single and Dual Channel Self Healing Rings for High Reliability

More information

Addendum HART Communication with the X2200 UV Flame Detector 1.1 4/

Addendum HART Communication with the X2200 UV Flame Detector 1.1 4/ Addendum HART Communication with the X2200 UV Flame Detector 1.1 4/09 Table Of Contents Interconnecting the HART Communicator with the Detector.... 1 HART Device Description Language.... 3 Detector Wiring.......................................

More information

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules Application The Addressable Control and Monitor mini modules are the latest technology for a loop powered module. Installed on the same loop with other devices such as detectors and manual call points,

More information

S5000 Gas Monitor. GMS5000.com

S5000 Gas Monitor. GMS5000.com S5000 Gas Monitor GMS5000.com A DETECTOR AS TOUGH AS YOU ARE... LOWER TEMPERATURE SPEC?... ARCTIC WINTERS IT HAS TO BE THE MOST RELIABLE PIECE OF EQUIPMENT OUT HERE IF THE DETECTOR DOESN T WORK, WE DON

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The

More information

Symphony Plus Combustion instruments

Symphony Plus Combustion instruments Combustion instruments Combustion instruments 1 [ 1 ] Flame Scanner integrated arrangement [ 2 ] Flame Scanner conventional arrangement Combustion instruments 2 Symphony Plus is the new generation of ABB

More information

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC Engineering Guideline pac-carriers Type 9195 for TRICON system TRICONEX TMR PLC 2 Engineering Guideline TRICON system 14.10.2009 Content Signal type Control system I/O cards type pac-carrier Channels Slots

More information

DTM Distributed Transmitter-Monitor

DTM Distributed Transmitter-Monitor DTM Distributed Transmitter-Monitor DTM10 Proximity Distributed Transmitter-Monitor (Shaft Vibration, Thrust Position and Speed) The DTM10 distributed vibration transmitter-monitor is ideal for monitoring

More information

ADDENDUM. xwatch Explosion-Proof Camera with X-Series Flame Detectors DESCRIPTION GENERAL APPLICATION INFORMATION

ADDENDUM. xwatch Explosion-Proof Camera with X-Series Flame Detectors DESCRIPTION GENERAL APPLICATION INFORMATION ADDENDUM xwatch Explosion-Proof Camera with X-Series Flame Detectors DESCRIPTION The xwatch Explosion-Proof Camera is available as a factory installed option with any of the Det Tronics X Series line of

More information

GETTING STARTED GUIDE NI DI, 30 V, Sourcing, 7 μs

GETTING STARTED GUIDE NI DI, 30 V, Sourcing, 7 μs GETTING STARTED GUIDE NI 9426 32 DI, 30 V, Sourcing, 7 μs This document explains how to connect to the NI 9426. Note Before you begin, complete the software and hardware installation procedures in your

More information

GETTING STARTED GUIDE NI AI/8 AO/4 DIO, 0 V to 5 V, 12 Bit, 20 ks/s Aggregate

GETTING STARTED GUIDE NI AI/8 AO/4 DIO, 0 V to 5 V, 12 Bit, 20 ks/s Aggregate GETTING STARTED GUIDE NI 9381 8 AI/8 AO/4 DIO, 0 V to 5 V, 12 Bit, 20 ks/s Aggregate This document explains how to connect to the NI 9381. Note Before you begin, complete the software and hardware installation

More information

Instructions IR Flame Detector X Rev: 6/

Instructions IR Flame Detector X Rev: 6/ Instructions 95-8554 IR Flame Detector X9800 Rev: 6/13 95-8554 Table of Contents Description.... 1 Outputs... 1 LED... 2 oi (Optical Integrity)... 2 Communication... 3 Data Logging... 3 Integral Wiring

More information

Instructions Infrared Hydrocarbon Gas Detector PointWatch Eclipse Model PIRECL Rev.10/

Instructions Infrared Hydrocarbon Gas Detector PointWatch Eclipse Model PIRECL Rev.10/ Instructions 95-8526 Infrared Hydrocarbon Gas Detector PointWatch Eclipse Model PIRECL Rev.10/12 95-8526 Table of Contents application... 1 OPERATION OVERVIEW.... 1 Theory of Operation... 1 Detectable

More information

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control. Détecteur de gaz OLCT80 Detectors-Transmitters for Flammable, Toxic Gases and Oxygen Non-intrusive operation via intrinsically safe infrared remote control Disponible en version déportée, ADF ou de SI

More information

EOTec 2C32 Installation Guide

EOTec 2C32 Installation Guide ControlNet Dual Ring Modules For the EOTec 2000 Series November 2008 Weed Instrument Company, Inc. 707 Jeffrey Way, P.O. Box 300 Round Rock, TX 78680-0300 USA Tel: 512-434-2850 Fax: 512-434-2851 E-mail:

More information

DET-TRONICS INSTRUCTIONS. Infrared Hydrocarbon Gas Detector PointWatch Eclipse Model PIRECL APPLICATION OPERATION OVERVIEW

DET-TRONICS INSTRUCTIONS. Infrared Hydrocarbon Gas Detector PointWatch Eclipse Model PIRECL APPLICATION OPERATION OVERVIEW DET-TRONICS INSTRUCTIONS Infrared Hydrocarbon Gas Detector PointWatch Eclipse Model PIRECL IMPORTANT Be sure to read and understand the entire instruction manual before installing or operating the gas

More information

Annunciator unit. Application

Annunciator unit. Application Issued: April 1999 Status: April 1999 Version: B/09.11.2001 Data subject to change without notice Features Flexible, field-customizable 16-channel annunciator unit Alarm channels activated by normally

More information

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2 DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2 Interactive fire detection systems Product Datasheet Features Interactive For interfacing and controlling external units to Autronica s interactive fire detection

More information

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS Engineering Guideline pac-carriers Type 9195 for Yokogawa ProSafe-RS 2 Engineering Guideline / Yokogawa ProSafe-RS 06.06.2017 Integrated solutions for Yokogawa R. STAHL offers a wide range of customized

More information

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors. Fire Sentry Corporation (FSC) 593 Apollo Street Tel.: 714-671-1100 Brea, California 92821 Fax: 714-671-5821 Multi-Spectral, Digital, Infrared Electro-Optical FSC Model No. s FS10-R and FS10-A Unitized,

More information

02/11/2015

02/11/2015 MIC48 With RS 485 link Part number 89422418 Heating and / or cooling function 2 independent alarms Load break detection 2 setpoint which can be selected remotely Manual / automatic power adjustment RS

More information

AO Annunciator Module

AO Annunciator Module General Specifications GS48C43Z01-00E-N AO-543-01 Annunciator Module GENERAL Figure 1 This module has two independent annunciator circuits. The circuits handle fault signals and operator actions (acknowledge,

More information

Dräger Flame 2350 (UV&IR) Flame Detection

Dräger Flame 2350 (UV&IR) Flame Detection Dräger Flame 2350 (UV&IR) Flame Detection The Dräger Flame 2350 combines UV and IR sensors for the detection of hydrocarbon-based fires. This combination of sensors offers you more security and fewer false

More information

Model 144H. Product Data Sheet , Rev DB February Content

Model 144H. Product Data Sheet , Rev DB February Content Rosemount 144 PC-Programmable Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement accuracy

More information

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY >OLYL >H]LSLUN[O 4H[[LYZ SMOKELESS FLARE MONITOR Smokeless Flare Monitor (FM) Smokeless flares incinerate flammable hazardous

More information

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Mass Flow Computers Series 155 The Kurz 155 Mass Flow Computer is a versatile system transmitter that integrates the functions of flow and temperature measurement, flow totalization,

More information

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers. ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page

More information

02/11/2015

02/11/2015 CTH 46 - CTD 43 / 46 CTD 46 Part number 89422108 CTH 46 Heating / cooling function Measurement and setpoint display CTD 43 Heating or cooling function Measurement display Measurement deviation display-setpoint

More information

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger Flame 2700 (Multi-IR) Flame Detection Dräger Flame 2700 (Multi-IR) Flame Detection With its multichannel IR sensor the Dräger Flame 2700 detects hydrocarbon- and hydrogen-based fires. Thereby it offers a high reliability against false alarms.

More information

Dräger Flame 2100 (UV) Flame Detection

Dräger Flame 2100 (UV) Flame Detection Dräger Flame 2100 (UV) Flame Detection A short response time and high reliability against false alarms are the features of the Dräger Flame 2100. Its UV sensor is quick to detect hydrocarbon- or hydrogen-based

More information

PSN-1000 & PSN 1000(E) Installation Manual

PSN-1000 & PSN 1000(E) Installation Manual PSN-1000 & PSN 1000(E) Installation Manual Potter Electric Signal Company, LLC St. Louis, MO Customer Service: (866) 240-1870 Technical Support: (866) 956-1211 Fax: (314) 595-6999 www.pottersignal.com

More information

Dräger Flame 2500 Flame Detection

Dräger Flame 2500 Flame Detection Dräger Flame 2500 Flame Detection Working in areas with combustible gases, vapours or materials requires fire/ flame detection as a life-saving necessity. The best solutions must combine state-of-the-art

More information

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/ Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/08 Table Of Contents Section I Installation and Startup.................. 1 INSTALLATION............................................

More information

Dräger Flame 2370 (UV&IR) Flame Detection

Dräger Flame 2370 (UV&IR) Flame Detection Dräger Flame 2370 (UV&IR) Flame Detection An extremely short response time and very high reliability against false alarms are the features of the Dräger Flame 2370. It is quick and reliable in detecting

More information

IntesisBox BACnet/IP Server - Notifier ID3000 series

IntesisBox BACnet/IP Server - Notifier ID3000 series IntesisBox Server - Notifier ID3000 series Gateway for integration of Notifier ID3000, ID3002, ID50 and ID60 fire panels into enabled control systems. Integrate your Notifier fire panels into your BACnet

More information

GAS DETECTORS. When every second counts

GAS DETECTORS. When every second counts GAS DETECTORS When every second counts PERFORMANCE AND SAFETY BEYOND COMPLIANCE We deliver rock-solid, performance-tested detectors for a wide variety of gas hazards, all with global approval. Our proven

More information

Annunciator Unit SACO 16 D1. Product Guide

Annunciator Unit SACO 16 D1. Product Guide Issued: Aprill 1999 Status: Updated Version: C/20.03.2006 Data subject to change without notice Features Flexible, field-customizable 16-channel annunciator unit Alarm channels activated by normally open

More information

Rosemount 3490 Series

Rosemount 3490 Series Product Data Sheet July 2014 00813-0100-4841, Rev DA Rosemount 3490 Series 4 20 ma + HART Compatible Controller Field mounted controller with integral multi-function LCD and keypad Tough weatherproof wall

More information

GETTING STARTED GUIDE NI AI, ±29.4 mv/v, 24 Bit, 10 ks/s/ch Simultaneous, 350 Ω Quarter-Bridge Completion

GETTING STARTED GUIDE NI AI, ±29.4 mv/v, 24 Bit, 10 ks/s/ch Simultaneous, 350 Ω Quarter-Bridge Completion GETTING STARTED GUIDE NI 9236 8 AI, ±29.4 mv/v, 24 Bit, 10 ks/s/ch Simultaneous, 350 Ω Quarter-Bridge Completion This document explains how to connect to the NI 9236. Note Before you begin, complete the

More information

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA) R SERIES 35-70 120 VAC Microprocessor-Based Direct Spark Ignition Control F-35-70 November 2015 FEATURES Safe start with DETECT-A-FLAME flame sensing technology Custom pre-purge and inter-purge timings

More information

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Tel: +44 (0)8 9388 Email: info@ Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel

More information

Dräger Flame 2500 (IR3) Flame Detection

Dräger Flame 2500 (IR3) Flame Detection Dräger Flame 2500 (IR3) Flame Detection With its triple IR sensor The Dräger Flame 2500 detects hydrocarbonbased fires even over greater distances. Moreover, it offers a high reliability against false

More information

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays AEGIS Conventional Fire Alarm-Suppression Control Unit FEATURES Agency Approvals FM Approved FM Approved to ANSI/UL 864, 9th edition FM Approved to ULC-S527-99 Other domestic U.S. approvals/listings pending/

More information

M2500 Engine Controller Installation Manual

M2500 Engine Controller Installation Manual M2500 Engine Controller Installation Manual Revision: 23-04-2012 Page 1 Contents 1 Preface... 4 2 Installation... 5 3 Terminal Connections... 6 4 Inputs... 7 4.1 Power Supply... 7 4.2 Mode/ Control Inputs...

More information

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM APPLICATION OVERVIEW Control and monitoring systems play an essential role in heat tracing applications which range from freeze protecting water lines to

More information

Industrial Grade Gas Detection

Industrial Grade Gas Detection Industrial Grade Gas Detection DETECTING THE... Difference Catalog #CB 0112 detcon inc. an company www.detcon.com Houston Odessa Shanghai Dammam Del Carmen Europe Company Profile ISO 9001: 2008 Certified

More information

Commercial and Light Industrial Fire Alarm Control Panel

Commercial and Light Industrial Fire Alarm Control Panel FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel Features Easily expandable. All new plug-in board design Two supervised audible circuits Lamp and system trouble circuit test Ground

More information

Flame Monitors BROCHURE

Flame Monitors BROCHURE Flame Monitors BROCHURE JUNHO 2013 monitor Self-monitoring and fail-safe compact flame monitor for the monitoring of gas, oil and coal flames with integrated UV, VIS or IR flame sensor, primarily in single

More information

Fire control panels FC360

Fire control panels FC360 Cerberus TM FIT Fire control panels FC360 FC361-ZZ, FC361-ZA, FC361-YZ, FC361-YA Fire control panels (1-loop) for addressable peripheral devices with integrated operating unit One loop with 126 addresses

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296

More information

Instructions. Det-Tronics SmokeWatch Explosion Proof Smoke Detector U Rev: 3/

Instructions. Det-Tronics SmokeWatch Explosion Proof Smoke Detector U Rev: 3/ Instructions Det-Tronics SmokeWatch Explosion Proof Smoke Detector U5015 Rev: 3/17 95-8723 Table of Contents OVERVIEW...1 FEATURES...1 BENEFITS...1 SPECIFICATIONS...2 OPERATION...3 Warm Up...3 Outputs...3

More information

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors Dräger Polytron 5100 EC Detection of toxic gases and vapors The Dräger Polytron 5100 EC is a cost-effective explosion proof transmitter for the detection of toxic gases or oxygen. It uses a high performance

More information

MBCE-110/230FR Flame Sensor Module

MBCE-110/230FR Flame Sensor Module MBCE-1001 FEBRAURY 6, 2017 MBCE-110/230FR Flame Sensor Module exida FMEDA SIL2 SEE NOTE 1 ON PAGE 4 DESCRIPTION The MBCE-110/230FR modules provide visual indication and electrical outputs that signal the

More information

Across-the-Line SERIES MP300 Combined Manual and Automatic

Across-the-Line SERIES MP300 Combined Manual and Automatic Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps

More information

5.1 Safety instructions for system configuration and explosion protection. Zone-specific conditions for system configuration

5.1 Safety instructions for system configuration and explosion protection. Zone-specific conditions for system configuration Planning and configuration of the I.S. 1 system 5 ENGINEERING 5.1 Safety instructions for system configuration and explosion protection During engineering, comply with the guidelines set out in EN 60 079-14.

More information

MBCE-110/230UV Flame Sensor Module

MBCE-110/230UV Flame Sensor Module MBCE-1002 FEBRUARY 3, 2017 MBCE-110/230UV Flame Sensor Module DESCRIPTION The MBCE-110/230UV modules provide visual indication and electrical outputs that signal the user regarding flame presence in a

More information

Technical Manual. Level Alarm Unit CARLA & WIDS

Technical Manual. Level Alarm Unit CARLA & WIDS CARLA & WIDS Technical Manual SAS au Capital de 2 158 244-444 871 933 R.C.S. Bourges - APE : 2651B Headquarter : 9, rue Isaac Newton - 18000 Bourges - France Technical Manual CARLA for Tankers Cargo Tanks

More information

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K PEGAsys Multi-Loop Intelligent Suppression Control System A UTC Fire & Security Company Effective: March 2007 K-76-028 FEATURES UL Listed CSFM Approved MEA Approved Peer-to-Peer Networking (to 32 nodes)

More information

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions Because every life has a purpose PrimaX IR Gas Transmitter Every feature of the SIL 2 engineered PrimaX IR Gas Transmitter

More information

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance

Combustible and Toxic Gas Detection Solutions. Performance and Safety Beyond Compliance Combustible and Toxic Gas Detection Solutions Performance and Safety Beyond Compliance Reliable Solutions from Det-Tronics, Your Partner in Safety Trusted Response with the Utmost Confidence Our proven

More information

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate GETTING STARTED GUIDE NI 9213 16 TC, ±78 mv, 24 Bit, 75 S/s Aggregate This document explains how to connect to the NI 9213. Note Before you begin, complete the software and hardware installation procedures

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information