CONSTRUCT JTC/TRS FACILITY FTEV
|
|
- Bertram Price
- 5 years ago
- Views:
Transcription
1 CONSTRUCT JTC/TRS FACILITY FTEV DRAWING LIST NO. SHEET NO. G-1 TITLE SHEET SHEET NAME C101 C201 EXIST SITE CONDITIONS / DEMOLITION PLAN SITE GEOMETRY PLAN CONTRACTOR HAUL ROUTE NORTH GATE C301 C401 C501 SITE GRADING PLAN SITE UTILITY PLAN SECTIONS & DETAILS S-1 GENERAL NOTES Downs Road 8 S-2 FOUNDATION PLAN TAXIWAY B 9 S-3 SECTIONS AND DETAILS 10 LS-1 LIFE SAFETY FLOOR PLAN 11 AS-1 ARCHITECTURAL SITE PLAN 12 A-1 FLOOR PLAN 13 A-2 ENLARGED FLOOR PLAN-SIMULATOR 14 A-3 ENLARGED TOILET PLAN & ELEVATIONS A-4 BUILDING ELEVATIONS Red Horse Road Cruz Avenue Red Horse Road PARALLEL TAXIWAY NORTH-SOUTH RUNWAY 9,600' x 150' N02º W Walkup Way A-5 REFLECTED CEILING PLAN A-6 A-7 A-8 A-9 A-10 A-11 FP101 FP501 P101 P102 M101 M501 M601 M701 ROOF PLAN SCHEDULES BUILDING SECTIONS WALL SECTIONS WALL SECTIONS DETAILS FIRE PROTECTION NEW WORK PLAN FIRE PROTECTION DETAILS PLUMBING NEW WORK PLAN - WASTE PLUMBING NEW WORK PLAN - WATER MECHANICAL NEW WORK PLAN MECHANICAL DETAILS MECHANICAL SCHEDULES MECHANICAL CONTROLS E-1 ELECTRICAL LEGEND, DETAILS & NOTES E-2 POWER & SIGNAL PLAN E-3 LIGHTING PLAN CONSTRUCT JTC/TRS FACILITY FTEV TITLE SHEET lly Street Hamby Place Westfall Circle Bedel Street Cruz Avenue Bennett Avenue Frazier Street Bennett Avenue Bedel Street TAXIWAY C TAXIWAY C EAST GATE Freedom Way Walkup Way E-4 LIGHTING DETAILS E-5 ELECTRICAL SITE PLAN T-1 COMMUNICATIONS FLOOR PLAN T-2 COMMUNICATIONS DETAILS T-3 COMMUNICATIONS DETAILS T-4 COMMUNICATIONS DETAILS T-5 COMMUNICATIONS SITE PLAN AIR FORCE SPECIAL OPERATIONS COMMAND 1 SPECIAL OPERATIONS CIVIL ENGINEER SQUADRON HURLBURT FIELD, FLORIDA Lukasik Avenue Tully Street Y D TAXIWAY D SITE PLAN SCALE: N.T.S Lielmanis Avenue Independence Road PROJECT SITE REGIONAL MAP G-1
2 C101
3 C201
4 C301
5 C401
6
7
8
9
10 1 2 LIFE SAFETY ANALYSIS NFPA 101 (2015 EDITION) 1-5 ASSUMPTION: THE PROTECTION METHOD ASSUMES A SINGLE FIRE SOURCE. IBC (2015) OCCUPANCY CLASSIFICATION: TYPE IIB, NON-COMBUSTIBLE CONSTRUCTION. ALLOWABLE HEIGHT AND AREA (TABLE 503): GROUP B: TYPE IIB ALLOWABLE HEIGHT: 4 STORIES; GROUP B: TYPE IIB ALLOWABLE AREA: 23,000 SF/FLOOR CAPACITY OF MEANS OF EGRESS: DEAD-END CORRIDORS: OCCUPANCY: 50 FEET MAXIMUM IN BUILDINGS PROTECTED THROUGHOUT BY SUPERVISED AUTOMATIC SPRINKLER SYSTEM. NFPA X 0.4 = 9.2 = 36" WIDE DOORS MINIMUM WIDTH OF EXIT ACCESS: NOT LESS THAN 36 INCHES NFPA A B KB ACTUAL PROJECT GROSS SQUARE FOOTAGE: NEW (ENCLOSED): 2,346 GSF NEW (UNDER OVERHANG): 136 GSF TOTAL: 2,482 GSF BUILDING IS FULLY PROTECTED BY AUTOMATIC FIRE SUPPRESSION SYSTEM, INCLUDING BENEATH ALL ACCESS FLOOR AREAS. NFPA 101, 2015 EDITION CLASSIFICATION OF OCCUPANCY: BUSINESS (B) NFPA 101 CHAPTER 38 HAZARD OF CONTENTS: ORDINARY HAZARD NFPA NO SPECIAL MINIMUM CONSTRUCTION REQUIREMENTS NFPA 101 CHAPTER 38, PARA OCCUPANT LOAD: ONE (1) PERSON PER 100 SQUARE FEET NFPA CHAPTER 7, TABLE ,346/100 = 23 OCCUPANTS MAXIMUM ALLOWED LEGEND PRIMARY EGRESS/CAPACITY FIRE ALARM SYSTEM MANUAL PULL STATION; MT 48" AFF TO C/L. SEE ELECTRICAL. FIRE ALARM FLUSH CEILING MOUNTED SPEAKER WITH FIRE ALARM AND CLEAR STROBES. SEE ELECTRICAL. FIRE ALARM FLUSH CEILING MOUNTED SPEAKER. SEE ELECTRICAL. FIRE ALARM/MASS NOTIFICATION WALL MOUNTED SPEAKER WITH FIRE ALARM CLEAR STROBE MOUNT 96" AFF TO TOP OF DEVICE. SEE ELECTRICAL. NUMBER OF EXITS: NOT LESS THAN (2) MEANS OF EGRESS SHALL BE PROVIDED FROM EACH BUILDING. ARRANGEMENT OF EXITS: IN ACCORDANCE WITH NFPA TRAVEL DISTANCE: COMMON PATH OF TRAVEL SHALL NOT EXCEED 100 FEET IN A BUILDINGS PROTECTED THROUGHOUT BY AN APPROVED SUPERVISED AUTOMATIC FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH (1). NFPA TRAVEL DISTANCE TO AN EXIT SHALL NOT EXCEED 300 FEET IN A BUSINESS OCCUPANCIES PROTECTED THROUGHOUT BY A SUPERVISED FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION 9.7 NFPA FIRE EXTINGUISHER CABINETS ARE LOCATED SUCH THAT TRAVEL DISTANCE TO A FIRE EXTINGUISHER FROM ANY POINT IN THE BUILDING DOES NOT EXCEED 75 FEET. KB FIRE ALARM SMOKE DETECTOR. SEE ELECTRICAL. RECESS-MOUNTED KNOX BOX WITHOUT TAMPER SWITCH, MODEL 3200, HINGED. MOUNTED MINIMUM OF 6'-0" ABOVE FINISH SLAB. FIRE ALARM/MASS NOTIFICATION SYSTEM-NEW LOCAL OPERATORS CONSOLE UNIT W/ EMERGENCY HVAC SHUT-OFF SWITCH. SEE ELECTRICAL. KEYNOTE. THIS SHEET ONLY. CONSTRUCT JTC/TRS FACILITY FTEV LIFE SAFETY FLOOR PLAN CEILING-MOUNTED EXIT LIGHT W/ DIRECTIONAL ARROWS C KEYNOTES: WALL MOUNTED EXIT LIGHT FIRE ALARM SYSTEM TAMPER SWITCH. SEE ELECTRICAL. FIRE ALARM SYSTEM FLOW SWITCH. SEE ELECTRICAL. WEATHERPROOF FIRE ALARM EXTERIOR WALL MOUNTED SPEAKER. MOUNT 96" ABOVE GRADE TO TOP OF DEVICE. SEE ELECTRICAL. ACCESS FLOOR SYSTEM. SEE SPECIFICATIONS. KEYNOTE, THIS SHEET ONLY. ROOM IDENTIFICATION. SEE ROOM FINISH SCHEDULE. AIR FORCE SPECIAL OPERATIONS COMMAND 1 SPECIAL OPERATIONS CIVIL ENGINEER SQUADRON HURLBURT FIELD, FLORIDA D NOTES: NORTH LIFE SAFETY FLOOR PLAN SCALE: 1/4"=1'-0" LS-1
11 NORTH SITE PLAN SCALE: 1/8"=1'-0" AS-1 AIR FORCE SPECIAL OPERATIONS COMMAND 1 SPECIAL OPERATIONS CIVIL ENGINEER SQUADRON HURLBURT FIELD, FLORIDA CONSTRUCT JTC/TRS FACILITY FTEV FLOOR PLAN
12 A B C D NORTH FLOOR PLAN SCALE: 1/4"=1'-0" 1 2 A-1 AIR FORCE SPECIAL OPERATIONS COMMAND 1 SPECIAL OPERATIONS CIVIL ENGINEER SQUADRON HURLBURT FIELD, FLORIDA CONSTRUCT JTC/TRS FACILITY FTEV FLOOR PLAN
13 NORTH ENLARGED FLOOR PLAN - SIMULATOR ROOM SCALE: 1/2"=1'-0" A-2 AIR FORCE SPECIAL OPERATIONS COMMAND 1 SPECIAL OPERATIONS CIVIL ENGINEER SQUADRON HURLBURT FIELD, FLORIDA CONSTRUCT JTC/TRS FACILITY FTEV ENLARGED FLOOR PLAN-SIMULATOR
14 ENLARGED PLAN - UNISEX TOILET 104 SCALE: 1/2"=1'-0" M1 SD HCLAV INTERIOR ELEVATION - UNISEX TOILET 104 SCALE: 1/2"=1'-0" NOTE: SEE FINISH SCHEDULE SHEET A-7 FOR RESTROOM FINISHES GB2 GB1 TTD HCWC GB1 GB2 HCWC TTD INTERIOR ELEVATION - UNISEX TOILET 104 SCALE: 1/2"=1'-0" A-3 AIR FORCE SPECIAL OPERATIONS COMMAND 1 SPECIAL OPERATIONS CIVIL ENGINEER SQUADRON HURLBURT FIELD, FLORIDA CONSTRUCT JTC/TRS FACILITY FTEV ENLARGED TOILET PLAN & ELEVATIONS
15 A-4 AIR FORCE SPECIAL OPERATIONS COMMAND 1 SPECIAL OPERATIONS CIVIL ENGINEER SQUADRON HURLBURT FIELD, FLORIDA CONSTRUCT JTC/TRS FACILITY FTEV BUILDING ELEVATIONS
16 A B C D NORTH 1 2 REFLECTED CEILING PLAN SCALE: 1/4"=1'-0" A-5 AIR FORCE SPECIAL OPERATIONS COMMAND 1 SPECIAL OPERATIONS CIVIL ENGINEER SQUADRON HURLBURT FIELD, FLORIDA CONSTRUCT JTC/TRS FACILITY FTEV REFLECTED CEILING PLAN
17 A B C D NORTH 1 2 ROOF PLAN SCALE: 1/4"=1'-0" MIN. 1 1/2" A-6 AIR FORCE SPECIAL OPERATIONS COMMAND 1 SPECIAL OPERATIONS CIVIL ENGINEER SQUADRON HURLBURT FIELD, FLORIDA CONSTRUCT JTC/TRS FACILITY FTEV ROOF PLAN
18 UNISEX TOILET SIGN `A' UNISEX TOILET SIGN `B' A-7 AIR FORCE SPECIAL OPERATIONS COMMAND 1 SPECIAL OPERATIONS CIVIL ENGINEER SQUADRON HURLBURT FIELD, FLORIDA CONSTRUCT JTC/TRS FACILITY FTEV SCHEDULES
19 A-8 AIR FORCE SPECIAL OPERATIONS COMMAND 1 SPECIAL OPERATIONS CIVIL ENGINEER SQUADRON HURLBURT FIELD, FLORIDA CONSTRUCT JTC/TRS FACILITY FTEV BUILDING SECTIONS
20 A-9 AIR FORCE SPECIAL OPERATIONS COMMAND 1 SPECIAL OPERATIONS CIVIL ENGINEER SQUADRON HURLBURT FIELD, FLORIDA CONSTRUCT JTC/TRS FACILITY FTEV WALL SECTIONS
21 A-10 AIR FORCE SPECIAL OPERATIONS COMMAND 1 SPECIAL OPERATIONS CIVIL ENGINEER SQUADRON HURLBURT FIELD, FLORIDA CONSTRUCT JTC/TRS FACILITY FTEV WALL SECTIONS
22 A-11 AIR FORCE SPECIAL OPERATIONS COMMAND 1 SPECIAL OPERATIONS CIVIL ENGINEER SQUADRON HURLBURT FIELD, FLORIDA CONSTRUCT JTC/TRS FACILITY FTEV DETAILS
23 FIRE PROTECTION NEW WORK PLAN FP101 D:\PROJECT\2015\15044 Construct JTC-TRS Facility\DWG\Mech\15044FP101.DWG, 1/12/2016 8:41:29 AM, DWG To PDF.pc3
24 FIRE PROTECTION DETAILS FP501 D:\PROJECT\2015\15044 Construct JTC-TRS Facility\DWG\Mech\15044FP501.DWG, 1/12/2016 8:41:32 AM, DWG To PDF.pc3
25 1 2 A B C CONSTRUCT JTC/TRS FACILITY FTEV AIR FORCE SPECIAL OPERATIONS COMMAND 1 SPECIAL OPERATIONS CIVIL ENGINEER SQUADRON PLUMBING NEW WORK PLAN - WASTE HURLBURT FIELD, FLORIDA D P101
26 AIR FORCE SPECIAL OPERATIONS COMMAND 1 SPECIAL OPERATIONS CIVIL ENGINEER SQUADRON HURLBURT FIELD, FLORIDA CONSTRUCT JTC/TRS FACILITY FTEV PLUMBING NEW WORK PLAN - WATER P102
27 MECHANICAL NEW WORK PLAN M101 D:\PROJECT\2015\15044 Construct JTC-TRS Facility\DWG\Mech\15044M101.DWG, 1/12/2016 8:41:35 AM, DWG To PDF.pc3
28 MECHANICAL DETAILS M501 D:\PROJECT\2015\15044 Construct JTC-TRS Facility\DWG\Mech\15044M501.DWG, 1/12/2016 8:41:38 AM, DWG To PDF.pc3
29 MECHANICAL SCHEDULES M601 D:\PROJECT\2015\15044 Construct JTC-TRS Facility\DWG\Mech\15044M601.DWG, 1/12/2016 8:41:40 AM, DWG To PDF.pc3
30 MECHANICAL CONTROLS M701 D:\PROJECT\2015\15044 Construct JTC-TRS Facility\DWG\Mech\15044M701.dwg, 1/12/2016 8:41:43 AM, DWG To PDF.pc3
31 E-1 ELECTRICAL LEGEND, DETAILS & NOTES
32 POWER & SIGNAL PLAN E-2
33 LIGHTING PLAN E-3
34 SENTROL SENTROL LIGHTING DETAILS E-4
35 PRIMARY DUCT BANK DETAIL NOT TO SCALE ELECTRICAL SITE PLAN PAD MOUNTED TRANSFORMER DETAILS NOTE: ALL GROUND CONNECTIONS SHALL BE BRAZED OR EXOTHERMIC WELDED E-5
36 COMMUNICATIONS FLOOR PLAN T-1
37 COMMUNICATIONS DETAILS T-2
38 COMMUNICATIONS DETAILS T-3
39 3" COMMUNICATIONS DETAILS T-4
40 COMMUNICATIONS SITE PLAN T-5
CORRALES INTERNATIONAL SCHOOL TENANT IMPROVEMENT 5500 WILSHIRE AVE NE ALBUQUERQUE, NM 87113
CORRALES INTERNATIONAL SCHOOL TENANT IMPROVEMENT DRAWING INDEX COVER SHEET G-101 FIRST FLOOR CODE ANALYSIS G-102 SECOND FLOOR CODE ANALYSIS G-103 CAFETERIA CODE ANALYSIS D-101 FIRST FLOOR DEMOLITION PLAN
More informationFIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY
FIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY PLAN REVIEWS SITE PLANS: 1) Access to buildings (Volume V NC Building Code sections 602.6.1
More informationMINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry
MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry Fire Alarm Systems Plan Review Checklist Date: Permit Number: Business Name: Address: Fire Alarm System Submittal
More informationPublic. Mike Free Health. State of Alabama Department of
State of Alabama Department of Mike Free Building Construction Specialist Technical Services Unit Office of Facilities Management Public 334-206-5221 334-206-5177 Health Fax: 334-206-5890 Web Site: www.adph.org.facmgmt
More informationPublic Health Fax: Web Site:
State of Alabama Department of Public Health Fax: 334-206-5890 Web Site: www.adph.org.facmgmt Mike Free Building Construction Specialist Technical Services Unit Office of Facilities Management 334-206-5221
More informationInternational Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures
International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures Please note this is not an all-inclusive list. The type and complexity of your project
More informationPlan Review Check List Fire Alarm System
Plan Review Check List Fire Alarm System EXCELSIOR FIRE DISTRICT 241OO SMITHTOWN ROAD SHOREWOOD, MN 55331 Alarm system must be installed according to NFPA 72, 2010 Edition, National Fire Alarm and Signaling
More informationFIRE AND SAFETY PROJECT REVIEW REPORT
1. A001 2. A001 3. A001 4. D102/103 5. A102/103 *VA enforces/applies the National Fire Protection Association (NFPA) 101 (current edition is 2015) and not the International Building Code (IBC). Ideally
More informationLarge Family Daycare Guideline
Moreno Valley Fire Department Fire Prevention Bureau Large Family Daycare Guideline Approved and Authorized By: Adria Reinertson, Fire Marshal Issued: April 10, 2017 Large Family Daycare Guideline Purpose
More informationH BUTCH BROWNING FIRE MARSHAL BUILDING REHABILITATION
STATE OF LOUISIANA Department of Public Safety and Corrections Office of State Fire Marshal Code Enforcement and Building Safety 8181 Independence Boulevard Baton Rouge, Louisiana 70806 225-925-4920 H
More informationMoreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline
Moreno Valley Fire Department Guideline Approved and Authorized By: Adria Reinertson, Fire Marshal Issued: May 8, 2017 Alarm & Signaling Systems PURPOSE Fire alarm and signaling systems are designed to
More informationFire Safety Evaluation of Existing Manufactured Educational Building Covered by Section 423 of the Florida Building Code
Walker Engineering, Inc. 833 Rockingham Road Birmingham Alabama 35235-2625 205-854-0160 205-854-0160 (Fax) Fire Safety Evaluation of Existing Manufactured Educational Building Covered by Section 423 of
More informationNFPA 45 NFPA 211 NFPA 1600
NFPA 45 NFPA 211 NFPA 1600 Prepared by: William E. Koffel, P.E., FSFPE Expertly Engineering Safety From Fire 1 Objectives Overview of the NFPA process Understand the scope and application of NFPA 45, NFPA
More informationCommercial Remodel/ Add On Rules and Regulations
Commercial Remodel/ Add On Rules and Regulations Public Works and Community Development Department City of Shenandoah 29955 I-45 North Shenandoah, Texas 77381 281-298-5522 www.shenandoahtx.us Construction
More informationThe Residences at Christina Landing Wilmington, DE
5.0 FIRE PROTECTION EXISTING CONDITIONS 5.1 Project Specific Fire Protection Data Codes, Regulations, and Standards Building Officials and Code administrators (BOCA) National Building Code [1996] with
More informationBy: Russell Bainbridge March 18th, 2016 FPE 596
By: Russell Bainbridge March 18th, 2016 FPE 596 Egress Analysis and Design California Polytechnic State University's Engineering IV building Fire Detection, Alarm and Communication Systems A warehouse
More informationCommercial Rules and Regulations
Commercial Rules and Regulations Public Works and Community Development Department City of Shenandoah 29955 I 45 North Shenandoah, Texas 77381 281 298 5522 www.shenandoahtx.us Construction Documents Submit
More informationDEALING WITH FIRE SAFETY
DEALING WITH FIRE SAFETY Personal Care Homes And Assisted Living Facilities Presented by: Harold D. Hicks, P.E., FSFPE Fire Protection Engineer 1 Atlantic Code Consultants 2 Our Objectives Recognize the
More informationEl Reno Fire Department Fire Alarm Plan Review Worksheet
El Reno Fire Department Fire Alarm Plan Review Worksheet This Fire Alarm Plan Review Checklist is provided as a guide to assist with your Fire Alarm Plan Review Submittal requirements. Please contact us
More informationFor the Florida Building Commission And the Fire Code Advisory Council
Life-Safety Modifications Mechanical and Existing Building Compared to the 2012 Changes of the International Building Code and National Fire Protection Association- 101 For the Florida Building Commission
More informationSCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL
SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL 3300 SUMMIT BOULEVARD WEST PALM BEACH, FLORIDA 33406 TEL (561) 688-7687 FAX (561) 688-7654 http://www.palmbeach.k12.fl.us/fm/bd/index.htm
More information2018 NICET Code Transition Changes
2018 NICET Code Transition Changes NICET will be transitioning to newer codes accepted in their exams in mid-october 2018, specifically: NFPA 72 2016 NFPA 70 2014 IBC 2015 NFPA 101 2015 Here are some changes
More informationPROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE
PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE Developed by the Midwestern Regional Work Group CONTENTS Item 15 Limited area sprinkler systems Item 20 Scope of IFC Ch 7 Item 21 Fire-resistance-rated
More informationAUTOMATIC FIRE SPRINKLER SYSTEMS
MCKINNEY FIRE DEPARTMENT FIRE MARSHAL S OFFICE AUTOMATIC FIRE SPRINKLER SYSTEMS These guidelines are to be followed when a business, facility or organization installs an automatic fire sprinkler system
More information2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.
2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge. Exception: Manual fire alarm boxes are not required where the building is
More informationAmerican Fire Sprinkler Association. An Introduction to the IBC and IFC
American Fire Sprinkler Association Presents An Introduction to the IBC and IFC October 13, 2005 Speaker Roland Huggins, P.E. Vice President of Engineering and Technical Services American Fire Sprinkler
More informationUniversity Design Standard Fire Alarm Systems
1.0 Overview University Design Standard Fire Alarm Systems This document provides Virginia Tech s standards for the design and installation of fire alarm systems and equipment in new construction, retrofit
More informationFIRE SAFETY INSPECTION REPORT
FIRE SAFETY INSPECTION REPORT PORTLAND TEXTILE LTD. ACCORD ID: 11873 PLOT NO. 14-15, SECTOR 6, CHITTAGONG EXPORT PROCESSING ZONE, CHITTAGONG OTHER FACTORIES: NONE November 3, 2015 Page 2 SUMMARY was surveyed
More informationFlorida Building Code 2010
Introduction Florida Building Code 2010 Chapter 9 Fire Protection Systems This course will cover specific sections of Chapter 9 that relate to fire alarm systems. While many contractors are familiar with
More informationItem Referenced and Amendments Building 1 Building 2 Analysis, Review and Remarks. Page 1 of 15
N/A N/A 2015 International Fire Code 2015 International Building Code Codes Jurisdictions for Fire and Building Codes Source of Information Building Fire Plumbing Mechanical Electrical Energy Code Accessibility
More informationBrighton Area Fire Authority
615 W. Grand River Ave. Brighton, MI 48116 o: 810-229-6640 f: 810-229-1619 January 14, 2019 Fire Alarm Contractors RE: Fire Alarm Credential & Submittal Requirements To Whom It May Concern: The following
More informationFOLD EXIT REQUIREMENTS MAX.TRAVEL DISTANCE ALLOWED: (TABLE ) MAX. COMMON PATH TRAVEL: (CBC ) MAX. DEAD ENDS: (TABLE 1018.
1 2 3 4 5 6 7 8 9 10 E D C B A N1808 A A B A.8 A A 13' - 0" 13' - 0" A.4 B A.8 28' - 6" 1' - 3" 26' - 0" 1' - 3" Level 1_Code 1 1/4" = 1'-0" Level 2_Code 2 1/4" = 1'-0" 1 1.6 2.2 2.7 1' - 3" 14' - 0" 15'
More informationCOMPLIANCE ALTERNATIVES
CHAPTER 12 COMPLIANCE ALTERNATIVES SECTION 1201 GENERAL 1201.1 Scope. The provisions of this chapter are intended to maintain or increase the current degree of public safety, health, and general welfare
More informationBuilding & Fire Code Academy. Building Better With Our Greatest Resource Education. Welcome!
Building & Fire Code Academy Building Better With Our Greatest Resource Education Welcome! Understanding the Sprinkler System Design Alternatives in the 2015 International Why inspect, test and maintain?
More information2012 International Fire Code Significant Changes. IFC Background. Purpose IBC and 2012 NFPA 101 Significant Means of Egress Changes
2012 International Fire Code Significant Changes Andrew M. Schneider, P.E. Senior Fire Protection Engineer aschneider@koffel.com Koffel Associates, Inc. www.koffel.com Expertly Engineering Safety From
More informationSECTION 907 FIRE ALARM AND DETECTION SYSTEMS
SECTION 907 FIRE ALARM AND DETECTION SYSTEMS 907.1 General. This section covers the application, installation, performance and maintenance of fire alarm systems and their components in new and existing
More informationCHAPTER 7 ALTERATIONS LEVEL
CHAPTER 7 ALTERATIONS LEVEL 2 SECTION 701 GENERAL 701.1 Scope. Level 2 alterations as described in Section 404 shall comply with the requirements of this chapter. Exception: Buildings in which the reconfiguration
More informationResidential-based Care Facility R-4 Guideline
Moreno Valley Fire Department Fire Prevention Bureau Residential-based Care Facility R-4 Guideline Approved and Authorized By: Adria Reinertson, Fire Marshal Issued: April 7, 2017 Residential-based Care
More informationPERFORMANCE COMPLIANCE METHODS
CHAPTER 13 PERFORMANCE COMPLIANCE METHODS SECTION 1301 GENERAL 1301.1 Scope. The provisions of this chapter shall apply to the alteration, repair, addition and change of occupancy of existing structures,
More informationSANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)
FIRE DEPARTMENT SANTA CLARA COUNTY 14700 Winchester Blvd., Los Gatos, CA. 95032-1818 (408) 378-4010 (408) 378-9342 (fax) www.sccfd.org STANDARD DETAILS & SPECIFICATIONS Spec No C-4 Rev. Date 03/10/10 SUBJECT:
More informationConstruction and Development Guide
Construction and Development Guide **Based on the 2014 Indiana Fire Prevention Code and relevant NFPA Codes and Standards ** Copyright 2018 Clay Fire CRRD 1 P a g e Table of Contents Map of Jurisdiction...
More informationFIRE/SMOKE BARRIER FUNDAMENTALS
FIRE/SMOKE BARRIER FUNDAMENTALS William E. Koffel, P.E., FSFPE President Koffel Associates, Inc. www.koffel.com wkoffel@koffel.com Expertly Engineering Safety From Fire OBJECTIVE Identify the different
More informationRichard B. Alpert, P.E. Senior FPE, Clark Nexsen
Richard B. Alpert, P.E. Senior FPE, Clark Nexsen Clark Nexsen is a Registered Provider with The American Institute of Architects Continuing Education Systems (AIA/CES). Credit(s) earned on completion of
More informationAUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)
AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations) This standard applies to the design and installation of automatic fire sprinkler systems in conjunction with
More informationCITY OF PASADENA FIRE DEPARTMENT
Page 1 of 8 CITY OF PASADENA FIRE DEPARTMENT INSTALLATION OF COMMERCIAL SPRINKLERS (Revised 12/10/2014) SCOPE: This standard applies to the design and installation of automatic fire sprinkler systems in
More informationConstruction Warehouse. FPE 596 Culminating Experience In Fire Protection Engineering Final Project (Spring 2014) By Ben Johnson
Construction Warehouse FPE 596 Culminating Experience In Fire Protection Engineering Final Project (Spring 2014) By Ben Johnson 1 Statement of Disclaimer This project report is a result of a class assignment;
More informationFIRE SAFETY INSPECTION REPORT
FIRE SAFETY INSPECTION REPORT AMAZON TEX KNIT FASHION LTD JOBEDA PLAZA, 85 AC DHAR ROAD KALIRBAZAR May 21, 2014 Page 2 SUMMARY was surveyed for fire safety on 5/21/2014 by Hughes Associates, Inc. This
More informationAgency for Health Care Administration
Page 1 of 34 ST - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS Statute or Rule Type Memo Tag These guidelines are meant solely to provide guidance to surveyors in the survey process. ST - K0001 - OTHER
More informationFIRE SAFETY INSPECTION REPORT
FIRE SAFETY INSPECTION REPORT RAISA FASHIONS LTD. ACCORD ID: 11741 PLOT# B63, BSCIC INDUSTRIAL ESTATE, KANCHPUR, SONORGAON, NARAYANGANJ OTHER FACTORIES: NONE February 27, 2015 Page 2 SUMMARY was surveyed
More informationINTERIOR FINISH REVIEW
APPR NO. FIRE CODE COMPLIANCE ITEM I000 I001 I005 I010 I015 I020 INTERIOR FINISH Plans shall bear the seal of a licensed Architect currently registered with the State of Georgia are required for final
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST FIRE AND LIFE SAFETY SYSTEMS FOR STRUCTURES FIVE OR MORE STORIES IN HEIGHT AND LESS THAN 75 FEET IN HEIGHT FROM THE POINT
More informationFlorida Building Code Chapter 9 Fire Protection Systems Advanced Course
Florida Building Code 2010 Chapter 9 Fire Protection Systems Advanced Course 1 Introduction This course will cover specific sections of Chapter 9 that relate to fire alarm systems. While many contractors
More informationPERFORMANCE COMPLIANCE METHODS
CHAPTER 13 PERFORMANCE COMPLIANCE METHODS SECTION 1301 GENERAL 1301.1 Scope. The provisions of this chapter shall apply to the alteration, repair, addition and change of occupancy of existing structures,
More informationJanuary 1, 2014 Mandatory Effective Date
2013 Kentucky Building Code Highlights Winnie Blythe, Technical Advisor Dept. of Housing, Buildings, and Construction winnie.blythe@ky.gov www.dhbc.ky.gov 502-573-0373 January 1, 2014 Mandatory Effective
More informationBuilding Self-Inspection Program
Building Self-Inspection Program www.tridentinsurance.net Lines of Business: Property, General Liability, Worker s Compensation, Public Official Liability Risk Control Strategy/Key Issues: Reduce physical
More informationMOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION
MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION Fire Alarm System Plan Review 2009 International Fire Code and 2010 NFPA 72 Date of Review // BLD201 - Project Address: Project Name: _ Professional
More informationINSTALLATION OF ACCESS FLOOR SYSTEMS IN GENERAL OFFICE AREA AND COMPUTER ROOM
INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: Mech Code 601 Effective: 2-07-79 DOCUMENT NO. P/BC 2002-018 Revised: 9-25-03 Previously Issued As: RGA 2-79, MGD101 INSTALLATION OF ACCESS FLOOR
More informationGENERAL AREAS OF INSPECTION
This information is intended to assist you in preparation for the annual high-rise inspection. This is not a complete list and the Inspector may identify other conditions or issues in the building that
More informationIBC Committee Responsibility Matrix January 2017
IBC Committee Responsibility Matrix January 2017 Chapter 1 ADMIN same Chapter 3 High-Hazard Group H 307.1 same IFC same Uses Other Than Group H 307.1.1 same IFC same Hazardoss Materials 307.1.2 307.2 IFC
More informationCOMPLIANCE ALTERNATIVES
CHAPTER 12 COMPLIANCE ALTERNATIVES SECTION 1201 GENERAL 1201.1 Scope. The provisions of this chapter are intended to maintain or increase the current degree of public safety, health, and general welfare
More informationFIRE PREVENTION STANDARDS
DATE: 04/11/02 APPROVED: NUMBER: FP0-010 REVISED: FIRE PREVENTION STANDARDS TITLE: Large Family Day Cares (9-14 kids) PURPOSE: The purpose of this standard is to acquaint the applicant with the applicable
More informationRetain. Retain. Retain. Board Advisory. Board Advisory. Retain. Disposition. (Statute, Rule, FBC, Industry)
Florida Specific Amendment Code Reference NFPA 101 Anytime a reference is made to NFPA 1 or NFPA 101 within this Code, it shall be 1.1.1.1 the Florida specific version of NFPA 1 and NFPA 101. The Florida
More informationChanges to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH)
Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH) The following represents a review of the Life Safety chapter of the new 2018 Joint Commission CAMH manual for
More informationHIGH-RISE RETROFIT ORDINANCES - NO and NO
INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: LAMC 91.8604 Effective: 9-06-90 DOCUMENT NO. P/BC 2002-054 Revised: 4-15-03 Previously Issued As: MGD 88 HIGH-RISE RETROFIT ORDINANCES - NO.
More informationFull Service Central Station Fire Alarm Listing Evaluation
Full Service Central Station Fire Alarm Listing Evaluation Listing Evaluation A UL Listing project includes: 1. Evaluating the central station facility for compliance with UL 827, Central-Station Alarm
More informationGUIDELINES FOR INSPECTING GROUND BASED SPARKLING DEVICE (GBSD) RETAIL SALES FACILITIES
OFFICE OF THE FIRE MARSHAL Worcester County GOVERNMENT CENTER - ONE WEST MARKET STREET - ROOM 1003 SNOW HILL, MARYLAND 21863-1194 TEL: 410-632-5666 FAX: 410-632-5664 GUIDELINES FOR INSPECTING GROUND BASED
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: A-Approved; AC-Approved
More informationTHE BASICS OF FIRE ALARM PLAN REVIEW
THE BASICS OF FIRE ALARM PLAN REVIEW Art Shaw A Shaw & Associates, LLC. ashaw@arthurshaw.com 231.838.3269 Fire Protection System Plan Reviewer FP000006 NFPA Certified Plans Examiner 02-0005 NFPA Certified
More informationYORK COUNTY DEPARTMENT OF FIRE SAFETY BUILDING PLAN REVIEW REQUIREMENTS
YORK COUNTY DEPARTMENT OF FIRE SAFETY BUILDING PLAN REVIEW REQUIREMENTS The York County Department of Fire Safety reviews all commercial building plan submittals for compliance with the 2015 International
More informationSANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST
July 1, 2010 SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST TENANT IMPROVEMENTS Address: Permit #: Inspector: Date: Status: Inspector: Date: Status: A-Approved; AC-Approved w/comments;
More informationAdvanced Fire Alarm Systems Training Program Outline (5 Day)
Advanced Fire Alarm Systems Training Program Outline (5 Day) Day 1 Prescriptive and Performance-Based Design Understand the methodology in accessing the threat of fire within a structure. Know the difference
More informationWORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES
1 WORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES TABLE 2.1 CONSTRUCTION OF STRUCTURAL MEMBERS AND FLOOR AND ROOF (1) ASSEMBLIES (Applies to each fire zone)
More informationSECTION INSPECTION AND TESTING OF WORK
SECTION 01455 PART I - GENERAL 1.01 SECTION INCLUDES A. Project Inspections and Procedures B. Scheduling Inspectors Notification requirements 1.02 RELATED SECTIONS A. Section 01310 COORDINATION B. Section
More informationRiverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)
Riverside County Fire Department Office of the Fire Marshal 2300 Market St., Ste. 150, Riverside, CA 92501 Ph. (951) 955-4777 Fax (951) 955-4886 Guideline Title: Residentially Based Care Facilities Group
More informationMAINTENANCE OF FIRE PROTECTION DEVICES WITHIN RESIDENTIAL SUITES OF MULTI-FAMILY BUILDINGS
FIRE CODE BULLETIN December 2004 97 FCB 018 (R1) Page 1 of 5 BACKGROUND: MAINTENANCE OF FIRE PROTECTION DEVICES WITHIN RESIDENTIAL SUITES OF MULTI-FAMILY BUILDINGS Fire protection service companies are
More informationFIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES
Established 1949 FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES The following are guidelines for new development. Any submitted plans must comply with these guidelines,
More informationFor additional information regarding R-3.1 residential care facilities please contact (951)
Riverside County Fire Department Fire/Life Safety Inspection Division Riverside Office: 2300 Market St., Ste. 150, Riverside, CA 92501 Ph. (951) 955-4823 Fax (951) 955-4886 Palm Desert Office: 77-933 Las
More informationPLAN REVIEW SUBMITTAL GUIDE
PLAN REVIEW SUBMITTAL GUIDE Plans, specifications and other construction documentation for the initial plan review should be as complete as possible at the time of submittal. Use this convenient guide
More informationS000 SITE REVIEW APPR NO. FIRE CODE COMPLIANCE ITEM
APPR NO. FIRE CODE COMPLIANCE ITEM S000 S001 S005 (Automobile Access Aisle) shall be a minimum of 5 ft wide, a common access aisle may be shared by 2 vehicles. Surface slopes shall not exceed 1:50(2%)
More informationHuman Factors - Egress Analysis for High Hazard Occupancies. Presented by: Michael J. Klemenz, PE, SFPE
Human Factors - Egress Analysis for High Hazard Occupancies Presented by: Michael J. Klemenz, PE, SFPE Group H Other SFPE presenters today discussed issues relevant to Group H This presentation addresses
More informationFIRE AND LIFE SAFETY ANALYSIS
FIRE AND LIFE SAFETY ANALYSIS AF Child Development Center Standard Design Judy Biddle Acknowledgements Special thanks for support and guidance over that past 2.5 years to: Professor Fred Mowrer Professor
More informationFire Hazard Analysis of Technical Area 53 Building 1
Fire Hazard Analysis of Technical Area 53 Building 1 June 11, 2015 LA-UR-15-23589 Slide 1 Introduction Brett Noakes Los Alamos National Laboratory Los Alamos, New Mexico Slide 2 Outline Background of the
More informationFIRE SAFETY INSPECTION REPORT
FIRE SAFETY INSPECTION REPORT YOUNG INTERNATIONAL PLOT NO. 32-36, SECTOR 5-CEPZ, CHITTAGONG OTHER FACTORIES: NONE July 20, 2014 Page 2 SUMMARY was surveyed for fire safety on 7/20/2014 by Hughes Associates,
More informationTaming the Health Care Building Codes NFPA vs. The International and Chicago Building Codes JENSEN & HALSTEAD LTD.
Taming the Health Care Building Codes NFPA vs. The International and Chicago Building Codes Comparing the Codes: NFPA 101 Life Safety Code (2000) (NFPA) International Building Code (2012) (IBC) Chicago
More informationNew Construction Fire Inspection Process
New Construction Fire Inspection Process This document is intended to provide the Owner, Designer, and/or Contractor of new construction with an outline of required fire inspections and with the specific
More informationRocky Mountain Fire Protection District 4390 Eldorado Springs Drive Boulder, CO
Rocky Mountain Fire Protection District 4390 Eldorado Springs Drive Boulder, CO 80303 303-494-3735 Contractor s Checklist and Installation Guide TABLE OF CONTENTS Fire Protection Narrative........... 3
More informationLife Safety - Means of Egress/Exits NFPA 101
Life Safety - Means of Egress/Exits NFPA 101 Properly designed exits provide a safe path of escape from a fire or other emergency environment. The means of egress (exits) should be arranged to permit all
More informationFIRE SERVICE FEATURES
CHAPTER 5 FIRE SERVICE FEATURES SECTION 501 GENERAL 501.1 Scope. Fire service features for buildings, structures and premises shall comply with this chapter. 501.2 Permits. A permit shall be required as
More informationPERFORMANCE COMPLIANCE METHODS
CHAPTER 13 PERFORMANCE COMPLIANCE METHODS SECTION 1301 GENERAL 1301.1 Scope. The provisions of this chapter ((shall)) apply to the alteration, repair, addition and change of occupancy of existing structures,
More informationAgency for Health Care Administration
Page 1 of 92 FED - K0000 - INITIAL COMMENTS Title INITIAL COMMENTS Type Memo Tag FED - K9999 - FINAL OBSERVATIONS Title FINAL OBSERVATIONS Type Memo Tag FED - KA100 - General Requirements - Other Title
More informationRecommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region
Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region The following sections, paragraphs, and sentences of the 2015 International Existing
More informationFIRE SAFETY INSPECTION REPORT
FIRE SAFETY INSPECTION REPORT M.S.ATTIRES LTD. ACCORD ID: 10887 A. RAHMAN PLAZA, SHANSHONGAON, FATULLAH, NARAYANGONJ OTHER FACTORIES: AISA FASHION LTD.; PRINT GARDEN LTD.; S.M. COLLECTION LTD. February
More informationCHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS
CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS 61G15-32.001 61G15-32.002 61G15-32.003 61G15-32.004 61G15-32.005 61G15-32.006 61G15-32.007
More informationFire Protection Coffee Break Training May 2016
Fire Protection Coffee Break Training May 2016 Introduction High-Rise Requirements Questions and Answers Agenda Overview Site Fire Access Aerial Access Power/Back-up Power Elevators and Access Sprinklers
More informationFire Sprinkler Plan Submittal Form
Contents Fire Sprinkler Plan Submittal Form... 2 Standpipe Plan Review Submittals... 4 Fire Pump Plan Submittal Requirements... 6 Fire Alarm Plan Submittal Form... 8 Kitchen Hood Wet Chemical Submittal...10
More informationWEST VIRGINIA UNIVERSITY
WEST VIRGINIA UNIVERSITY Environmental Health and Safety (SOP) WV State Fire Marshal (SFM) Project Plans Review Process & Procedures West Virginia University Environmental Health & Safety Page 1 of 10
More informationChapter 2: Definitions
FLORIDA BUILDING CODE Existing Buildings 6 TH Edition (2017) Code Changes based on the document provided by DBPR - 2014 and 6th Edition (2017) Florida Building Code Comparison JUMP TO CHAPTER (click chapter
More informationDefend In Place 2012 IFC Overview of Institutional Occupancies
Defend In Place 2012 IFC Overview of Institutional Occupancies ICC Course No. ICC CEU s = 0.50 SCFA Course 8506-15-0 Nathan Ellis Cell: 864-812-5183 Nathan.Ellis@llr.sc.gov Institutional Occupancies Course
More informationAPPENDIX H (DESIGN SUBMISSION CRITERIA)
APPENDIX H (DESIGN SUBMISSION CRITERIA) FIRE ALARM SYSTEM As per ACCORD standard Part 5, section 5.7 Fire Alarm System Design to be verified by ACCORD Chief Safety Inspector. Testing of the installation
More informationFire & Life Safety Supplemental Rules & Regulations for New Construction & Significant Remodels
DEPARTMENT OF PUBLIC SAFETY FIRE MARSHAL S OFFICE 9611 SE 36 TH ST Mercer Island, WA 98040 (206) 236-3515 direct; (206) 236-3622 FAX Rod Mandery, Fire Marshal Updated version: 03-19-2002 Fire & Life Safety
More information