CE MARKING PROCESS & NOTIFIED BODIES

Size: px
Start display at page:

Download "CE MARKING PROCESS & NOTIFIED BODIES"

Transcription

1 CE MARKING PROCESS & NOTIFIED BODIES Ellis Garai Ramin Miri Spring 2011 GLOBAL BIODESIGN STANFORD UNIVERSITY

2 Machinery 9% Others 49% Construction 11% Notified Bodies Industrial and Medical Devices 8% NAWI 23% Geographical Distribution NB*Directive (~1500) 5% 2% AI 1% EU 27 (Others), 11 Germany, 6 UK, 1 Italy, 1 AI UK 21% Italy 18% Germany 21% NBs (969) France 8% Other 32% EU 27 (Others) 28% EFTA, 2% MRA-PECA MRA-PECA, 1 EFTA, 7 EU 27 (Others), 36 Germany, 16 UK, 6 Italy, 10

3 Identify Appropriate Directive Identify Appropriate Classification within Directive (Annex IX) Class I (non-sterile/ non-measuring) Class I (sterile/measuring) AI Class IIa Class IIb Class III Strategically Select appropriate Notified Body - NB s area of expertise - Strategic partner s history with specific NBs Establish Quality Management Sys. (Annex II, V, VII; ISO 13485:2003) Actively Functioning Quality Management System Technical File- Class II Design Dossier- Class III Essential Requirements (Annex I) Clinical Evaluation (Annex X) Appoint Authorized Representative (a.k.a. EC Rep) Formal Notified Body Audit Notified Body Issues CE Mark Certificate Declaration of Conformity (Annex VII) Class I devices require registration Translation of Documentation: User Manuals & Labels (23 languages) Place Product on the European Market Annual Notified Body Audits to maintain CE Mark certification Post Market Surveillance System must be in place Incident Reports must be filed Corrective & Preventative Action (CAPA)- part of QMS

4 Identify Appropriate Directive Identify Appropriate Classification within Directive (Annex IX) Class I (non-sterile/ non-measuring) Class I (sterile/measuring) AI Class IIa Class IIb Class III Strategically Select appropriate Notified Body - NB s area of expertise - Strategic partner s history with specific NBs Establish Quality Management Sys. (Annex II, V, VII; ISO 13485:2003) Actively Functioning Quality Management System Appoint Authorized Representative (a.k.a. EC Rep) Formal Notified Body Audit Notified Body Issues CE Mark Certificate Declaration of Conformity (Annex VII) Place Product on the European Market Technical File- Class II There are three medical device directives. The manufacturer must prove that Design Dossier- Class III their product complies with the appropriate directive. : Medical Devices Directive (90/42/EEC & 2007/47/EC) AI: Active Implantable Medical Devices Directive (90/385/EEC & 2007/47/EC) : In Vitro Diagnostic Device Directive (98/79/EC) Essential Requirements (Annex I) Translation of Documentation: User Manuals & Labels (23 languages) Clinical Evaluation (Annex X) Class I devices require registration Annual Notified Body Audits to maintain CE Mark certification Post Market Surveillance System must be in place Incident Reports must be filed Corrective & Preventative Action (CAPA)- part of QMS

5 Identify Appropriate Directive Identify Appropriate Classification within Directive (Annex IX) Class I (non-sterile/ non-measuring) Class I (sterile/measuring) AI Class IIa Class IIb Class III Strategically Select appropriate Notified Body - NB s area of expertise - Strategic partner s history with specific NBs Establish Quality Management Sys. (Annex II, V, VII; ISO 13485:2003) Actively Functioning Quality Management System Appoint Authorized Representative (a.k.a. EC Rep) Notified Body Issues CE Mark Certificate Place Product on the European Market Technical File- Class II Medical devices are grouped by classification depending on the level of Design Dossier- Class III risk to the patient. Essential Requirements (Annex I) The major factors in determining the class of a medical device is the primary mode of action and operation. Translation of Documentation: User Manuals & Labels (23 languages) Clinical Evaluation (Annex X) It is the responsibility of the manufacturer to indentify which class their Formal Notified Body Audit product fall under, but ultimately confirmed by the Notified body There are 18 rules found in Annex IX of the that helps the Declaration of Conformity (Annex VII) manufacturer determined the appropriate classification for a particular product. Class I devices require registration Annual Notified Body Audits to maintain CE Mark certification Post Market Surveillance System must be in place Incident Reports must be filed Corrective & Preventative Action (CAPA)- part of QMS

6 Identify Appropriate Directive Identify Appropriate Classification within Directive (Annex IX) Class I (non-sterile/ non-measuring) Class I (sterile/measuring) AI Class IIa Class IIb Class III Strategically Select appropriate Notified Body - NB s area of expertise - Strategic partner s history with specific NBs Establish Quality Management Sys. (Annex II, V, VII; ISO 13485:2003) Actively Functioning Quality Management System Technical File- Class II Design Dossier- Class III Essential Requirements (Annex I) Clinical Evaluation (Annex X) ISO 13845:2003 Appoint Authorized Representative (a.k.a. EC Rep) Medical devices Formal -- Quality Notified Body management Audit systems -- Requirements for regulatory purposes Notified Body Issues CE Mark Certificate Main sections of ISO 13485: Section 4.0: Declaration Quality of Management Conformity (Annex System VII) Requirements Section Translation 5.0: of Management Documentation: Responsibility User Manuals & Labels Section 6.0: Resource (23 languages) Management Section 7.0: Product Realization Place Product on the European Market Section 8.0: Measurement, Analysis, and Improvement Class I devices require registration Annual Notified Body Audits to maintain CE Mark certification Post Market Surveillance System must be in place Incident Reports must be filed Can take up to 3-9 months to implement Corrective & Preventative Action (CAPA)- part of QMS

7 Identify Appropriate Directive Identify Appropriate Classification within Directive (Annex IX) Class I (non-sterile/ non-measuring) Class I (sterile/measuring) AI Class IIa Class IIb Class III Strategically Select appropriate Notified Body - NB s area of expertise - Strategic partner s history with specific NBs Establish Quality Management Sys. (Annex II, V, VII; ISO 13485:2003) Actively Functioning Quality Management System Technical File- Class II Design Dossier- Class III Essential Requirements (Annex I) Clinical Evaluation (Annex X) Components of the Technical File: Product Description Intended Use Technical Drawings Standards Used Product Specification Design Requirements Product performance testing Packaging & Labeling Transportation and storage Construction requirements Annual Notified Body Audits to maintain CE Mark certification Manufacturing Documentation Appoint Authorized Representative (a.k.a. EC Rep) Formal Notified Body Audit Notified Body Issues CE Mark Certificate Declaration of Conformity (Annex VII) Translation of Documentation: User Manuals & Labels (23 languages) Place Product on the European Market Post Market Surveillance System must be in place Pre-clinical testing: Bench & Animal Clinical Evaluation Biocompatibility (ISO 10993) - Systemic toxicity - EtO sterilization residuals - Potential degradation products Risk Management: (ISO 14971) - Risk analysis, evaluation, & control - Production & post-production info Incident Reports must be filed Class I devices require registration Corrective & Preventative Action (CAPA)- part of QMS

8 Identify Appropriate Directive Identify Appropriate Classification within Directive (Annex IX) Class I (non-sterile/ non-measuring) Class I (sterile/measuring) AI Class IIa Class IIb Class III Strategically Select appropriate Notified Body - NB s area of expertise - Strategic partner s history with specific NBs Establish Quality Management Sys. (Annex II, V, VII; ISO 13485:2003) Actively Functioning Quality Management System Technical File- Class II Design Dossier- Class III Essential Requirements (Annex I) Clinical Evaluation (Annex X) Forms of Clinical Evaluation: Scientific Review of the Literature Preclinical Testing: - Bench Testing - Animal Testing Annual Notified Body Audits to maintain CE Mark certification Appoint Authorized Representative (a.k.a. EC Rep) Formal Notified Body Audit Notified Body Issues CE Mark Certificate Declaration of Conformity (Annex VII) Post Market Surveillance System must be in place Incident Reports must be filed Class I devices require registration Human Clinical Evaluation: Translation of Documentation: User Manuals & Labels -ISO :2009 Clinical Investigation (23 languages) of Medical Devices for Human Subjects, General Requirements Place Product on the European Market -ISO :2009 Clinical Investigation of Medical Devices for Human Subjects, Investigation Plan - Clinical Evaluation Reports (CER) section of the MEDDEV Corrective & Preventative Action (CAPA)- part of QMS

9 Identify Appropriate Directive Identify Appropriate Classification within Directive (Annex IX) Class I (non-sterile/ non-measuring) Class I (sterile/measuring) AI Strategically Select appropriate Notified Body - NB s area of expertise - Strategic partner s history with specific NBs Establish Quality Management Sys. (Annex II, V, VII; ISO 13485:2003) Actively Functioning Quality Management System Appoint Authorized Representative (a.k.a. EC Rep) Formal Notified Body Audit Notified Body Issues CE Mark Certificate Declaration of Conformity (Annex VII) Place Product on the European Market Class IIa Class IIb Class III /AI/ BSI Group, UK TÜV SÜD, Germany NSAI, Ireland Technical File- Class II Design Dossier- Class III Essential Requirements (Annex I) AI/ General TÜV Nord, Germany AI Specific EMKI, Hungary - Implantable heart pacemakers POLSKIE C BI, Poland - AI auditive prosthesis (Cochlear Imp) Translation of Documentation: User Manuals & Labels (23 languages) Clinical Evaluation (Annex X) Class I devices require registration Annual Notified Body Audits to maintain CE Mark certification Post Market Surveillance System must be in place Incident Reports must be filed Corrective & Preventative Action (CAPA)- part of QMS

10 General NBs in Medical Devices

11 Full Spectrum NB Japan PAL Mexico & Brazil Canada CMDCAS Health USA FDA BSI group UK Founded in 1901 Non-Profit under Royal Chapter 235.3m Revenue 2591 Employees Australia MRA-CE KiteMark - Medical Devices QMS (ISO 13485) CE Marking 16 Direc., all 3 s

12 AI NBOG Codes AIMDs Product Categorization 0100: General AIs 0101: AIMDs for stimulation / inhibition 0102: AIMDs delivering drugs or other substances 0103: AIMDs substituting or replacing organ functions & AI SCOPE EXPRESSIONS, ADDITIONS MDS 7000: / AI Specifics MDS 7004: s referencing the Directive 2006/42/EC on machinery MDS 7005: s referencing the Directive 89/686/EEC on personal protective equipment (PPE) MDS 7006: s in sterile condition

13 AI (90/385/EEC) Products Implantable active monitoring devices Implantable Nerve Stimulators Stimulators Implantable active drug administration Implantable cardiac Programmers, software, transmitters Cochlear implants Bladder Sphincter Diaphragm Devices Catheters Sensors Pacemakers Defibrillators Leads, electrodes, adaptors

14 Specific AI NB Preparation and exchange information, and Preevaluating group EMKI Hungary /AI/ But only implantable heart pacemakers in AI directive Specialized in pacemakers Classification of C.A. scope (NBGO), and Calculating the time interval of C.A. procedures Designating the members of C.A. group, and making a bid Planning, performing, & Closure of C.A. procedure, and Decision about Conformity Issuing, modifying, or supplementing certificates Suspending, withdrawing, or constraining certificates Transparency and reproducibility of C.A. procedure Conformity Assessment

15 Specific AI NB EMKI Hungary /AI/ But only implantable heart pacemakers in AI directive Specialized in pacemakers Preparation and exchange information, and Preevaluating group In case of sole Classification of C.A. scope (NBGO), and Calculating the time interval of C.A. procedures product line of implantable heart Designating the members of C.A. group, and making a bid pacemaker, and Planning, performing, & Closure of C.A. procedure, and Decision about Conformity being a start-up, or Issuing, modifying, or supplementing certificates prior strategic Suspending, withdrawing, or constraining certificates partnership with Transparency and reproducibility of C.A. procedure EMKI C.A. Conformity Assessment

16 Identify Appropriate Directive AI Strategically Select appropriate Notified Body - NB s area of expertise - Strategic partner s history with specific NBs Actively Functioning Quality Management System Identify Appropriate Classification within Directive (Annex IX) The Authorize Representative acts as a regulatory liaison between each Class I (non-sterile/ non-measuring) country's ministry of health (aka Competent Authorities) and the company. Class I (sterile/measuring) Class IIa Class IIb Class III Authorized Representative Function: Has access to technical files if review is requested by Competent Authorities Aids in Product Establish Registration Quality process Management Sys. Technical File- Class II Aids in Incident Reporting (Annex II, V, VII; ISO 13485:2003) Design Dossier- Class III Recall Notification Change Notification Essential Requirements (Annex I) Clinical Evaluation (Annex X) Appoint Authorized Representative (a.k.a. EC Rep) Formal Notified Body Audit Notified Body Issues CE Mark Certificate Declaration of Conformity (Annex VII) Class I devices require registration Translation of Documentation: User Manuals & Labels (23 languages) Place Product on the European Market Annual Notified Body Audits to maintain CE Mark certification Post Market Surveillance System must be in place Incident Reports must be filed Corrective & Preventative Action (CAPA)- part of QMS

17 Identify Appropriate Directive Identify Appropriate Classification within Directive (Annex IX) Class I (non-sterile/ non-measuring) Class I (sterile/measuring) AI Technical File Audit : $10-15k Class IIa Class IIb Class III Strategically Select appropriate Notified Body - NB s area of expertise - Strategic partner s history with specific NBs Establish Quality Management Sys. (Annex II, V, VII; ISO 13485:2003) Quality System Audit: $3.5-4k Actively Functioning Quality Management System TOTAL Cost: ~$20,000 Appoint Authorized Representative (a.k.a. EC Rep) Formal Notified Body Audit Notified Body Issues CE Mark Certificate Technical File- Class II Design Dossier- Class III Essential Requirements (Annex I) Clinical Evaluation (Annex X) Declaration of Conformity (Annex VII) Class I devices require registration Translation of Documentation: User Manuals & Labels (23 languages) Place Product on the European Market Annual Notified Body Audits to maintain CE Mark certification Post Market Surveillance System must be in place Incident Reports must be filed Corrective & Preventative Action (CAPA)- part of QMS

18 Conformity Assessment Procedure Options Based on Directive A Aa B C D E F G H Internal production control Intervention of a Notified Body EC type-examination Conformity to type Production quality assurance Product quality assurance Product verification Unit verification Full quality assurance

19 Notified Body s Roles within CEM Certification Identify the Directive (s) applicable to product Full Quality Assurance Examination of the Design Type Examination Verification Production and Product Quality Assurance Identify the conformity assessment procedure based on product & Directive Determine key milestones and actionable schedule Identify if there are any Harmonized European Standards Ensure product compliance with all the essential requirements of the Directive(s)

20 Notified Body s Roles within CEM Certification Full Quality Assurance Examination of the Design Type Examination Verification Production and Product Quality Assurance Identify whether independent assessment of conformity is required by NBs Maintain Technical Documentation required by the Directive(s) Prepare the Declaration of Conformity and the required supporting evidence Check that no other purely national requirements exist in the market country Affix CE marking on the product and/or packaging

21 Identify Appropriate Directive Identify Appropriate Classification within Directive (Annex IX) Class I (non-sterile/ non-measuring) Class I (sterile/measuring) AI Class IIa Class IIb Class III Strategically Select appropriate Notified Body - NB s area of expertise - Strategic partner s history with specific NBs Establish Quality Management Sys. (Annex II, V, VII; ISO 13485:2003) Actively Functioning Quality Management System Technical File- Class II Design Dossier- Class III Essential Requirements (Annex I) Clinical Evaluation (Annex X) Appoint Authorized Representative (a.k.a. EC Rep) Formal Notified Body Audit Notified Body Issues CE Mark Certificate Declaration of Conformity (Annex VII) Class I devices require registration Translation of Documentation: User Manuals & Labels (23 languages) Place Product on the European Market Annual Notified Body Audits to maintain CE Mark certification Post Market Surveillance System must be in place Incident Reports must be filed Corrective & Preventative Action (CAPA)- part of QMS

22 Identify Appropriate Directive Identify Appropriate Classification within Directive (Annex IX) Class I (non-sterile/ non-measuring) Class I (sterile/measuring) AI Components: Class IIa Class IIb Class III Product identification Establish Quality Management Sys. Product classification (Annex II, V, VII; ISO 13485:2003) EU directives with which the product complies Standards used Actively Functioning Quality Management System Name of the Notified Body used The manufacturer's name and address Appoint Authorized Representative CE Mark certificate number (a.k.a. EC Rep) Signature on behalf of the manufacturer or EC Rep. Strategically Select appropriate Notified Body - NB s area of expertise - Strategic partner s history with specific NBs Formal Notified Body Audit Technical File- Class II Design Dossier- Class III Essential Requirements (Annex I) Clinical Evaluation (Annex X) Notified Body Issues CE Mark Certificate Declaration of Conformity (Annex VII) Class I devices require registration Translation of Documentation: User Manuals & Labels (23 languages) Place Product on the European Market Annual Notified Body Audits to maintain CE Mark certification Post Market Surveillance System must be in place Incident Reports must be filed Corrective & Preventative Action (CAPA)- part of QMS

23 Identify Appropriate Directive Identify Appropriate Classification within Directive (Annex IX) Class I (non-sterile/ non-measuring) Class I (sterile/measuring) AI Class IIa Class IIb Class III Strategically Select appropriate Notified Body - NB s area of expertise - Strategic partner s history with specific NBs Establish Quality Management Sys. (Annex II, V, VII; ISO 13485:2003) CE Mark is recognized by all 27 countries within the European Union (EU) as well as others in the region that are not necessarily part of the EU plus Canada, Australia, etc. around the globe Actively Functioning Quality Management System Appoint Authorized Representative (a.k.a. EC Rep) Formal Notified Body Audit Notified Body Issues CE Mark Certificate Declaration of Conformity (Annex VII) Place Product on the European Market Technical File- Class II Design Dossier- Class III Essential Requirements (Annex I) Translation of Documentation: User Manuals & Labels (23 languages) Clinical Evaluation (Annex X) Class I devices require registration Annual Notified Body Audits to maintain CE Mark certification Post Market Surveillance System must be in place Incident Reports must be filed Corrective & Preventative Action (CAPA)- part of QMS

24 EU Medical Device Classification & CE Mark Requirements Summary EU Class Class I (nonsterile/ nonmeasuring) Class I (sterile/ measuring) Class IIa Class IIb Class III Device Risk Low Low Medium Medium High Type of devices examination gloves surgical gloves, patient scales Natural Orifice Access; wound management; hearing devices, EKG, etc. Partial/Total Implantable; surgical lasers, ventilators Devices that affect vital organs; Life Support; heart valves Technical File Required Yes Yes, in the form of a Design Dossier Requires Full Quality System No Yes Requires NB Auditing No; Self declaration of conformity by manufacturer is acceptable Yes Requires Authorized Representative Yes Form of Clinical Evaluation Possible Scientific Literature Review Scientific Literature Review; Preclinical Work; Possible clinical trial Highly Likely that clinical trial is required Requires device to be Registered Yes No ; Notified Body conducts annual audits

Table of Contents for the REGULATION (EU) 2017/745 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 5 April 2017

Table of Contents for the REGULATION (EU) 2017/745 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 5 April 2017 Chapter I o Scope and definitions Article 1 Subject matter and scope 13 Article 2 Definitions 15 Article 3 Amendment of certain definitions 20 Article 4 Regulatory status of products 20 Chapter II o Making

More information

Want to know more about the Notified Body? Everything you need to know to help you through the Notified Body process and on to accreditation.

Want to know more about the Notified Body? Everything you need to know to help you through the Notified Body process and on to accreditation. Want to know more about the Notified Body? Everything you need to know to help you through the Notified Body process and on to accreditation. 1 Contents 3 Meet the world with confidence 4 What is CE marking?

More information

Achieve Success with European Medical Device Commercialization. By Russ King

Achieve Success with European Medical Device Commercialization. By Russ King Achieve Success with European Medical Device Commercialization By Russ King Achieve Success with European Medical Device Commercialization Given the complexity of the FDA s regulatory pathway, many medical

More information

Reporting Changes to your Notified Body

Reporting Changes to your Notified Body Reporting Changes to your Notified Body Ibim Tariah 1) Requirements & Guidance 2) Reporting Changes - What, When, Why & How 3) Some examples 4) Summary & Questions 2 Requirements of the Medical Directives

More information

C 183/10 Official Journal of the European Union

C 183/10 Official Journal of the European Union C 183/10 Official Journal of the European Union 7.7.2010 Commission communication in the framework of the implementation of the Council Directive 90/385/EEC of 20 June 1990 on the approximation of the

More information

(Notices) EUROPEAN COMMISSION

(Notices) EUROPEAN COMMISSION 24.1.2013 Official Journal of the European Union C 22/1 IV (Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION Commission communication in the framework

More information

(Notices) EUROPEAN COMMISSION

(Notices) EUROPEAN COMMISSION 18.1.2011 Official Journal of the European Union C 16/1 IV (Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION Commission communication in the framework

More information

New Requirements for Placing of Medical Devices on the Market: Conformity Assessment to the Technical Regulations

New Requirements for Placing of Medical Devices on the Market: Conformity Assessment to the Technical Regulations New Requirements for Placing of Medical Devices on the Market: Conformity Assessment to the Technical Regulations September 2015 This summer the medical device circulation reform became one of the most

More information

OFFICIAL JOURNAL OF ACTIVE IMPLANTABLE MEDICAL DEVICES DIRECTIVE (90/385/EEC)

OFFICIAL JOURNAL OF ACTIVE IMPLANTABLE MEDICAL DEVICES DIRECTIVE (90/385/EEC) OFFICIAL JOURNAL OF ACTIVE IMPLANTABLE MEDICAL DEVICES DIRECTIVE (90/385/EEC) Try it for free on: https://ce-marking.help This Free of Charge application was designed to help manufacturers, consultants,

More information

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2015/C 014/04)

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2015/C 014/04) C 14/36 EN Official Journal of the European Union 16.1.2015 Commission communication in the framework of the implementation of Council Directive 90/385/ EEC of 20 June 1990 on the approximation of the

More information

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 389/02)

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2017/C 389/02) C 389/22 EN Official Journal of the European Union 17.11.2017 Commission communication in the framework of the implementation of Council Directive 90/385/ EEC on the approximation of the laws of the Member

More information

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2016/C 173/02)

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2016/C 173/02) C 173/92 EN Official Journal of the European Union 13.5.2016 Commission communication in the framework of the implementation of Council Directive 90/385/ EEC on the approximation of the laws of the Member

More information

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 PPE-R/00.017 Version 2 RECOMMENDATION FOR USE Number of pages: 5 Approval stage : Approved on : Origin : Horizontal Committee, C2D Ad hoc group

More information

CE marking & your legal obligations

CE marking & your legal obligations CE marking & your legal obligations This presentation is intended to provide a practical approach guide to what you need to know about the CE marking requirements for electrical and electronic equipment

More information

Notification of a Body in the framework of a technical harmonization directive

Notification of a Body in the framework of a technical harmonization directive Notification of a Body in the framework of a technical harmonization directive From : Zentralstelle der Länder für Gesundheitsschutz bei Arzneimitteln und Medizinprodukten (ZLG) Heinrich-Böll-Ring 10 53119

More information

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR TF N 635 Regulation 574_2014: Annex III CPR and Regulation 568_2014: Annex V CPR 30-05-2014 28.5.2014 L 159/41 REGULATIONS COMMISSION DELEGATED REGULATION (EU) No 574/2014 of 21 February 2014 amending

More information

Record of Amendments. Version Date Amendment Section/page affected

Record of Amendments. Version Date Amendment Section/page affected Industry support for effective compliance BTHA Guidance on The Restriction Of The Use Of Certain Hazardous Substances In Electrical and Electronic Equipment (recast) (RoHS) Directive 2011/65/EU Comparison

More information

CE marking & your legal obligations

CE marking & your legal obligations CE marking & your legal obligations This presentation is intended to provide a practical approach guide to what you need to know about the CE marking requirements for electrical and electronic equipment

More information

SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE)

SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE) SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE) SCS/SF/053-8 Issue 1 Sira Certification Service INTRODUCTION One of the conditions placed on all holders of Sira

More information

The New PPE Regulation (EU) 2016/425

The New PPE Regulation (EU) 2016/425 The New PPE Regulation (EU) 2016/425 Dave Tuplin Certification Manager, BSI 1 PPE Regulation (EU) 2016/425 changes Agenda Who is BSI Landscape and timeframes Scope of the new PPE Regulation Categorisation

More information

BUSINESS PLAN CEN-CLC/TC 3 QUALITY MANAGEMENT AND CORRESPONDING GENERAL ASPECTS FOR MEDICAL DEVICES EXECUTIVE SUMMARY

BUSINESS PLAN CEN-CLC/TC 3 QUALITY MANAGEMENT AND CORRESPONDING GENERAL ASPECTS FOR MEDICAL DEVICES EXECUTIVE SUMMARY Page: 1 BUSINESS PLAN CEN-CLC/TC 3 QUALITY MANAGEMENT AND CORRESPONDING GENERAL ASPECTS FOR MEDICAL DEVICES EXECUTIVE SUMMARY Business Environment The area of responsibility of CEN-CLC/TC 3 Quality management

More information

AUGUST 2016 CONTENTS:

AUGUST 2016 CONTENTS: EMC SERVICES NEWSLETTER AUGUST 2016 CONTENTS: RECENT STANDARD CHANGES NEW FCC REGULATIONS IEC 60601-1-2 4TH EDITION LOW VOLTAGE DIRECTIVE EU DIRECTIVES EMC DIRECTIVE 2014/30/EU KOREA UPDATE: KN32/35 1.

More information

The PPE Directive and the PPE Regulation

The PPE Directive and the PPE Regulation PPE Regulation (EU) 2016/425 The PPE Directive and the PPE Regulation The history and future of PPE Certification A whitepaper The current PPE Directive at a glance The PPE Directive was one of the first

More information

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC Quick Introduction to TÛV Denmark TÜV Denmark - is a part of the TÜV NORD Group a global Organisation f Certification and Inspection of: Quality Management Systems, Products, Processes and Qualification

More information

European Regulations of Medical Devices and In-vitro Diagnostic Medical Devices. The Notified Body Point of View

European Regulations of Medical Devices and In-vitro Diagnostic Medical Devices. The Notified Body Point of View European Regulations of Medical Devices and In-vitro Diagnostic Medical Devices The Notified Body Point of View Dr.-Ing. Christian Zietsch Berlin 2018-06-20 Preliminary notes All information given, are

More information

Record of Amendments. Version Date Amendment Section/page affected

Record of Amendments. Version Date Amendment Section/page affected Industry support for effective compliance BTHA Guidance - The Low Voltage Directive (LVD) Directive 2014/35/EU On the harmonisation of the laws of the Member States relating to the making available on

More information

UL Health Sciences Industry Case Study: Skanray Technologies

UL Health Sciences Industry Case Study: Skanray Technologies UL Health Sciences Industry Case Study: Skanray Technologies Skanray Technologies, Mysore India High Technology medical start-up company in India gains access to global regulatory markets by partnering

More information

EUROPEAN UNION. Brussels, 13 February 2014 (OR. en) 2011/0357 (COD) PE-CONS 54/13 ENT 190 MI 550 CONSOM 128 COMPET 470 CODEC 1481

EUROPEAN UNION. Brussels, 13 February 2014 (OR. en) 2011/0357 (COD) PE-CONS 54/13 ENT 190 MI 550 CONSOM 128 COMPET 470 CODEC 1481 EUROPEAN UNION THE EUROPEAN PARLIAMT THE COUNCIL Brussels, 13 February 2014 (OR. en) 2011/0357 (COD) PE-CONS 54/13 T 190 MI 550 CONSOM 128 COMPET 470 CODEC 1481 LEGISLATIVE ACTS AND OTHER INSTRUMTS Subject:

More information

Declaration of Conformity Declaration of Performance Notes

Declaration of Conformity Declaration of Performance Notes What difference is there in the information to be included in the Declaration of Performance under the CPR (as updated by Delegated Act (EU) No. 574/2014) from that currently provided in the Declaration

More information

The transition requirements of the new Regulation (EU) 2016/425 of the European Parliament and of the Council on personal protective equipment

The transition requirements of the new Regulation (EU) 2016/425 of the European Parliament and of the Council on personal protective equipment expert guide / The transition requirements of the new Regulation (EU) 2016/425 of the European Parliament and of the Council on personal protective equipment www.arco.co.uk contents What you need to know

More information

DID YOU GET USED TO THE NEW CPR? HERE S A QUICK REVIEW!

DID YOU GET USED TO THE NEW CPR? HERE S A QUICK REVIEW! June 2018 DID YOU GET USED TO THE NEW CPR? HERE S A QUICK REVIEW! How to recognize compliant cables? The new CPR defines the rules and the requirements of construction products to be manufactured, distributed

More information

(1135/2016) Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland

(1135/2016) Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland Electrical Safety Act (1135/2016) By decision of Parliament, the following is enacted:

More information

International Product Compliance and Certifications. Product Safety Consulting, Inc.

International Product Compliance and Certifications. Product Safety Consulting, Inc. International Product Compliance and Certifications - USA - Canada - Europe - Other International - CB Scheme Agenda This was the only mark. Now, these are the marks A bit of history.. UL founded in 1894

More information

Council Directive 93/68/EEC of 22 July 1993 amending Directives

Council Directive 93/68/EEC of 22 July 1993 amending Directives Council Directive 93/68/EEC of 22 July 1993 amending Directives 87/404/EEC (simple pressure vessels), 88/378/EEC (safety of toys), 89/106/EEC (construction products), 89/336/EEC (electromagnetic compatibility),

More information

PENALTIES. All imported products are required to meet the same standards as domestic goods. National Safety Requirements. Customs Requirements

PENALTIES. All imported products are required to meet the same standards as domestic goods. National Safety Requirements. Customs Requirements 1 of 15 Short Course On: Importation Requirements of Laser Products ICALEO 2006 Version 11-01-06wbkgrd Course Topics Discuss the penalties associated with improperly or illegally importing a laser product.

More information

(recast) (Text with EEA relevance) out the conformity assessment procedure. Conformity 20 February 2014.

(recast) (Text with EEA relevance) out the conformity assessment procedure. Conformity 20 February 2014. 29.3.2014 Official Journal of the European Union L 96/357 DIRECTIVE 2014/35/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 26 February 2014 on the harmonisation of the laws of the Member States relating

More information

BUSINESS PLAN CEN/TC 239 RESCUE SYSTEMS EXECUTIVE SUMMARY

BUSINESS PLAN CEN/TC 239 RESCUE SYSTEMS EXECUTIVE SUMMARY Page: 1 BUSINESS PLAN CEN/TC 239 RESCUE SYSTEMS EXECUTIVE SUMMARY Business Environment CEN/TC 239 is engaged in the standardization of ambulances as emergency medical vehicles and/or crafts and their associated

More information

ENABLING MARKET ACCESS RADIO EQUIPMENT DIRECTIVE (RED) 2014/53/EU. The new radio equipment directive in detail

ENABLING MARKET ACCESS RADIO EQUIPMENT DIRECTIVE (RED) 2014/53/EU. The new radio equipment directive in detail ENABLING MARKET ACCESS RADIO EQUIPMENT DIRECTIVE () 2014/53/EU The new radio equipment directive in detail RADIO EQUIPMENT DIRECTIVE () 2014/53/EU The new radio equipment directive in detail As of 13/06/2017,

More information

New Legal Framework Carlo Casati

New Legal Framework Carlo Casati New Legal Framework Carlo Casati Milan, 1 April 2016 Summary New Legislative Framework Market Surveillance Conformity Assessment CE Marking 2 06.11.2013 NOTIFIED BODY TRAINING 01 New Legislative Framework

More information

MARKING EC Directive 97/23 PED (Pressure Equipment Directive)

MARKING EC Directive 97/23 PED (Pressure Equipment Directive) MARKING EC Directive 97/23 PED (Pressure Equipment Directive) Field of application The Directive applies to the design, manufacturing and conformity assessment of the pressure equipment and of their groups

More information

Guidance on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) Regulations 2012

Guidance on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) Regulations 2012 Guidance on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS) Regulations 2012 Two Parts: 1. Products first placed on the market between 1 July 2006

More information

The New EMC Directive 2004/108/EC

The New EMC Directive 2004/108/EC The New EMC Directive 2004/108/EC In the process of this review I have tried to spell out in words what is often referred to as a section number while also keeping to location information as used in the

More information

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax: STANDARD FOR CERTIFICATION No. 2.9 RADAR REFLECTOR JANUARY 2003 Veritasveien 1, N-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD is an autonomous and independent Foundation with

More information

DIRECTIVE 2014/34/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL

DIRECTIVE 2014/34/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL 29.3.2014 Official Journal of the European Union L 96/309 DIRECTIVE 2014/34/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 26 February 2014 on the harmonisation of the laws of the Member States relating

More information

The European Radio Equipment Directive 2014/53/EU

The European Radio Equipment Directive 2014/53/EU TÜV SÜD Slide 1 The European Radio Equipment Directive 2014/53/EU 28 March 2017 Meet the speaker behind the voice Jon Lea Senior Engineer (Product Certification), TÜV SÜD 30 years experience in the testing

More information

West Virginia University Laser Safety Program

West Virginia University Laser Safety Program I. Statement, Purpose, and Scope A. Statement: The University is committed to providing a safe and healthful workplace; this includes evaluating and taking action to prevent laser related exposures. B.

More information

Guidance Note No 19/1. CE Marking windows and doorsets

Guidance Note No 19/1. CE Marking windows and doorsets Guidance Note No 19/1 CE Marking windows and doorsets What is CE marking? The CE marking of products in the European Union is used by manufacturers to indicate that their products conform to requirements

More information

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034 Guidance Note No 21/1 CE Marking Windows and doorsets to BS EN 16034 Introduction CE Marking of construction products has been a legal requirement since July 2013. It is a European requirement for all

More information

MARINE GYRO COMPASS STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

MARINE GYRO COMPASS STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax: STANDARD FOR CERTIFICATION No. 2.9 MARINE GYRO COMPASS JANUARY 2003 Veritasveien 1, N-1322 Høvik, Norway Tel.: +47 67 57 99 00 Fax: +47 67 57 99 11 FOREWORD is an autonomous and independent Foundation

More information

Do you manufacture equipment or protective systems for use in potentially explosive atmospheres? Do you process, trade or import them?

Do you manufacture equipment or protective systems for use in potentially explosive atmospheres? Do you process, trade or import them? TÜV NORD CERT GmbH Geschäftsstelle Hannover Am TÜV 1 30519 Hannover Zertifizierung Certification body for equipment according to Directive 94/9/EC of TÜV NORD CERT GmbH Summarized Information Directive

More information

Active implantable medical devices -- Part 2-3: Particular requirements for cochlear and auditory brainstem implant systems

Active implantable medical devices -- Part 2-3: Particular requirements for cochlear and auditory brainstem implant systems Irish Standard I.S. EN 45502-2-3:2010 Active implantable medical devices -- Part 2-3: Particular requirements for cochlear and auditory brainstem implant systems NSAI 2010 No copying without NSAI permission

More information

Certificate of Registration

Certificate of Registration Certificate of Registration QUALITY MANAGEMENT SYSTEM - ISO 13485:2003 & EN ISO 13485:2012 This is to certify that: Sanatmetal Orthopaedic & Traumatologic Equipment Manufacturer Ltd. Faiskola u. 5. 3300

More information

Medical devices and electromagnetic compatibility. Addressing the requirements of IEC , 4 th Edition

Medical devices and electromagnetic compatibility. Addressing the requirements of IEC , 4 th Edition Medical devices and electromagnetic compatibility Addressing the requirements of IEC 60601-1-2, 4 th Edition Executive Summary Risk of electromagnetic interference and immunity have long been important

More information

Regulation (EC) 1272/2008 on Classification, labelling and packaging. (CLP Regulation) DG Environment

Regulation (EC) 1272/2008 on Classification, labelling and packaging. (CLP Regulation) DG Environment Regulation (EC) 1272/2008 on Classification, labelling and packaging of substances and mixtures (CLP Regulation) DG Environment GHS Global Context Rio, 1992 Chapter 19 of UNCED Agenda 21 Development by

More information

Valve Manufacturers Association of America

Valve Manufacturers Association of America BUSINESS ASSURANCE Valve Manufacturers Association of America 2016 Technical Seminar: EU s New Legislation Framework (NLF) - What this means to you. Mike Norman 1 VMA Technical Session - March 2016 SAFER,

More information

ISO Safety of machinery Laser processing machines Part 1: General safety requirements

ISO Safety of machinery Laser processing machines Part 1: General safety requirements INTERNATIONAL STANDARD ISO 11553-1 First edition 2005-02-01 Safety of machinery Laser processing machines Part 1: General safety requirements Sécurité des machines Machines à laser Partie 1: Prescriptions

More information

Living with the Construction Products Directive - The Role of the Notified Bodies

Living with the Construction Products Directive - The Role of the Notified Bodies Living with the Construction Products Directive - The Role of the Notified Bodies Francky Callewaert DG Enterprise The core of the CE marking Is obligatory for every construction product placed on the

More information

The New EMC Directive 2004/108/EC

The New EMC Directive 2004/108/EC The New EMC Directive 2004/108/EC In the process of the review I have tried to spell out in words what is often referred to as a section number. This helps reduce the need to flip pages as one reads this.

More information

Health Technology Assessment (HTA) in Croatia

Health Technology Assessment (HTA) in Croatia Health Technology Assessment (HTA) in Croatia Mirjana Huić, MD, MSc Assistant Director Department for Development, Research and HTA Agency for Quality and Accreditation in Health Zagreb, Croatia HTA Multidisciplinary

More information

1. Which national directives/laws control the placing on the market of equipment for explosive atmospheres?

1. Which national directives/laws control the placing on the market of equipment for explosive atmospheres? QUESTIONS TO REGULATORS 1. Which national directives/laws control the placing on the market of equipment for explosive atmospheres? Note: This answer only relates to coal mining in the state of New South

More information

Chain saws (electric mains powered and battery powered)

Chain saws (electric mains powered and battery powered) Compliance Guide Edition 09/2016 Chain saws (electric mains powered and battery powered) European Garden Machinery Federation EGMF Bd Reyers 80, 1030 Brussels, Belgium secretariat@egmf.org +32 2 206 68

More information

Lawnmowers, pedestrian controlled (combustion engine powered)

Lawnmowers, pedestrian controlled (combustion engine powered) Compliance Guide Rev.1, 09/2016 Lawnmowers, pedestrian controlled (combustion engine powered) European Garden Machinery Federation EGMF Bd Reyers 80, 1030 Brussels, Belgium secretariat@egmf.org +32 2 206

More information

HazLoc Essential Guides:

HazLoc Essential Guides: HazLoc Essential Guides: Intertek Deeside Lane, Chester, CH1 6DD UK hazloc@intertek.com +44 1244 882590 www.intertek-hazloc.com Contents Contents... 1 Introduction... 1 Introduction to Ex... 1 ATEX Overview...

More information

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group "Pressure"

Pressure Equipment Directive PED 2014/68/EU Commission's Working Group Pressure D. EVALUATION ASSESSMENT PROCEDURES Guideline D-01 Guideline related to: Annex III, module G Is design approval by a notified body required under module G? Module G does not explicitly require formal design

More information

Safety requirement compliance for Lasers

Safety requirement compliance for Lasers Safety requirement compliance for Lasers in Medical and Beauty Care Applications Building off UL s history of more than 120 years of safety science, UL s Health Sciences division provides comprehensive

More information

Commentary from a Certification Body. Mike Violette Director American Certification Body

Commentary from a Certification Body. Mike Violette Director American Certification Body Commentary from a Certification Body Mike Violette Director American Certification Body mikev@acbcert.com Background inarte-certified EMC Engineer Professional Engineer (Virginia) Founder, Washington Laboratories

More information

Australian/New Zealand Standard

Australian/New Zealand Standard AS/NZS 3200.2.4:2006 IEC 60601-2-4:2005 AS/NZS 3200.2.4:2006 Australian/New Zealand Standard Medical electrical equipment Part 2.4: Particular requirements for safety Cardiac defibrillators AS/NZS 3200.2.4:2006

More information

CE marking & your legal obligations

CE marking & your legal obligations CE marking & your legal obligations This presentation is intended to provide a practical approach guide to what you need to know about the CE marking requirements for electrical and electronic equipment

More information

EN ISO ÖNORM. Edition: (ISO 14937:2009)

EN ISO ÖNORM. Edition: (ISO 14937:2009) ÖNORM EN ISO 14937 Edition: 2010-03-15 Sterilization of health care products General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization

More information

ISO INTERNATIONAL STANDARD. Safety of machinery Laser processing machines Part 1: General safety requirements

ISO INTERNATIONAL STANDARD. Safety of machinery Laser processing machines Part 1: General safety requirements INTERNATIONAL STANDARD ISO 11553-1 First edition 2005-02-01 Safety of machinery Laser processing machines Part 1: General safety requirements Sécurité des machines Machines à laser Partie 1: Prescriptions

More information

SCESm Directory Accreditation number: SCESm 0013

SCESm Directory Accreditation number: SCESm 0013 International standard: ISO/IEC 17021-1:2015 Swiss standard: SN EN ISO/IEC 17021-1:2015 Swiss Safety Center AG Certifications Richtistrasse 15 8304 Wallisellen Head: Responsible for MS: Heinrich A. Bieler

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Accredited to ISO17065:2012 to provide product conformity Octagon House Concorde Way Segensworth North Fareham Hampshire PO15 5RL Contact: Mr Mark Jenkins Tel: +44 (0) 1489 558258 Fax: +44 (0)1489 558101

More information

1. Terms defined in the Construction Products Regulation (CPR)

1. Terms defined in the Construction Products Regulation (CPR) CEN/TC 351 Glossary of relevant terms related to the CPR The following list of terms provides definitions of terms related to the CPR (EU/305/2011) which are relevant for the work of CEN/TC 351 Construction

More information

SCESm Directory Accreditation number: SCESm 0013

SCESm Directory Accreditation number: SCESm 0013 International standard: ISO/IEC 17021-1:2015 Swiss standard: SN EN ISO/IEC 17021-1:2015 Swiss Safety Center AG Certifications Richtistrasse 15 8304 Wallisellen Head: Responsible for MS: Heinrich A. Bieler

More information

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA - TF N 530 Rev.2 2012-04-13 CONSTRUCTION SECTOR STANDARDIZATION GUIDANCE DOCUMENT Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA - 1 Drafting

More information

Annex of the certificate (Page 1/1) Accreditation Scope

Annex of the certificate (Page 1/1) Accreditation Scope Accreditation Nr: ISO 22000:2005 Food Safety Management System Certification Address : E-Mail Website : kys@szutest.com.tr : www.szutest.com.tr Class/Category Food and Feed Processing - C Food and Feed

More information

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to BS EN 16034: 2014 Permission to reproduce extracts from BS EN 16034 : 2014 is granted by BSI. DHF BEST PRACTICE

More information

Brush cutters Grass Trimmers (combustion engine powered)

Brush cutters Grass Trimmers (combustion engine powered) Compliance Guide Rev.1, 09/2016 Brush cutters Grass Trimmers (combustion engine powered) European Garden Machinery Federation EGMF Bd Reyers 80, 1030 Brussels, Belgium secretariat@egmf.org +32 2 206 68

More information

Business Quality Assurance International Ltd

Business Quality Assurance International Ltd Business Quality Assurance International Ltd Woodvale House, Clarinbridge, Co. Galway Management System Certification Body Registration number: 5007 is accredited by the Irish National Board (INAB) to

More information

COMPILATION OF COMMUNITY PROCEDURES ON INSPECTIONS AND EXCHANGE OF INFORMATION

COMPILATION OF COMMUNITY PROCEDURES ON INSPECTIONS AND EXCHANGE OF INFORMATION EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL Consumer goods Pharmaceuticals European Medicines Agency Inspections London, 18 May 2009 EMEA/INS/GMP/313510/2006 Rev 1 COMPILATION OF COMMUNITY

More information

EC Certificate - Full Quality Assurance System Directive 93/42/EEC on Medical Devices, Annex II excluding Section 4

EC Certificate - Full Quality Assurance System Directive 93/42/EEC on Medical Devices, Annex II excluding Section 4 No. CE 616020 In respect of: Design, development and manufacture of sterile power injectable implantable infusion ports, sterile long term hemodialysis catheters, and non-sterile ECG-based peripherally

More information

best practice guide BS EN 14846: 2008 Electromechanically operated locks & striking plates to in association with

best practice guide BS EN 14846: 2008 Electromechanically operated locks & striking plates to in association with best practice guide Electromechanically operated locks & striking plates to BS EN 14846: 2008 in association with Permission to reproduce extracts from BS 3621:2007 and BS EN 12209: 2003 is granted by

More information

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA - TF N 687rev1 2015-06-02 CONSTRUCTION SECTOR STANDARDIZATION GUIDANCE DOCUMENT Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA - 1 I - Drafting

More information

AS/NZS IEC :2016

AS/NZS IEC :2016 Australian/New Zealand Standard AS/NZS IEC 60601.2.25:2016 (IEC 60601-2-25, Ed. 2.0:2011, IDT) Medical electrical equipment Part 2.25: Particular requirements for the basic safety and essential performance

More information

This is a preview - click here to buy the full publication. IEC Quality Assessment System for Electronic Components (IECQ System)

This is a preview - click here to buy the full publication. IEC Quality Assessment System for Electronic Components (IECQ System) QC 080000 Edition 3.0 2012-05 IECQ PUBLICATION IEC Quality Assessment System for Electronic Components (IECQ System) Hazardous Substance Process Management System Requirements (HSPM) INTERNATIONAL ELECTROTECHNICAL

More information

JBCE input for the RoHS FAQ document

JBCE input for the RoHS FAQ document JBCE input for the RoHS FAQ document JBCE welcomes the recast of the RoHS Directive 2011/65/EU (hereafter generally referred to as RoHS 2 ) 1 and appreciates the ongoing work by the Commission in realizing

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Accredited to ISO17065:2012 to provide product conformity Octagon House Concorde Way Segensworth North Fareham Hampshire PO15 5RL Contact: Mr Mark Jenkins Tel: +44 (0) 1489 558258 Fax: +44 (0)1489 558101

More information

The new Gas Appliances Regulation (EU) 2016/426

The new Gas Appliances Regulation (EU) 2016/426 The new Gas Appliances Regulation (EU) 2016/426 Background and overview A Whitepaper What is happening? As of 21 April 2018, the Gas Appliances Directive 2009/142/EC (GAD) will be replaced by the new Gas

More information

Frequently Asked Questions on the Construction Products Regulation (CPR) - Enterprise and Industry

Frequently Asked Questions on the Construction Products Regulation (CPR) - Enterprise and Industry 1. Must a construction product bear the CE marking after 30/06/2013? After 30/06/2013, in order to sell a construction product in the European Union (EU) the manufacturer has the obligation to issue a

More information

Technical Bulletin CE marking: from 1st July 2013

Technical Bulletin CE marking: from 1st July 2013 Technical Bulletin CE marking: from 1st July 2013 New regulation New obligations Same CE mark We are facing the most significant change for a decade in the way that construction products are manufactured

More information

BIOLOGICAL EVALUATION OF MEDICAL

BIOLOGICAL EVALUATION OF MEDICAL IRISH STANDARD I.S. EN ISO 10933-12:2007 ICS 11.100.20 BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 12: SAMPLE PREPARATION National Standards Authority of Ireland Glasnevin, Dublin 9 Ireland Tel: +353

More information

Sýnishorn Health care services - Quality management systems - Requirements based on EN ISO 9001:2015

Sýnishorn Health care services - Quality management systems - Requirements based on EN ISO 9001:2015 ÍST EN 15224:2016 Gildistaka 15.3.2017 ICS: 3.12 Health care services - Quality management systems - Requirements based on EN ISO 9001:2015 Staðfestur af Staðlaráði Íslands Staðlaráð Íslands - Eftirprentun

More information

New Approach vs Standards and Regulation: how it all works

New Approach vs Standards and Regulation: how it all works New Approach vs Standards and Regulation: how it all works between the EU and an EU Member State (UK example) Volodymyr Yakubov Senior Standardization Expert, INOGATE Head of International Projects, BSI

More information

Controlled Door Closing Devices

Controlled Door Closing Devices Controlled Door Closing Devices to BS EN 1154: 1997 + A1:2003 www.dhfonline.org.uk 01 dhf Best Practice dhf Best Practice : Controlled Door Closing Devices to BS EN 1154: 1997 + A1:2003 dhf Best Practice

More information

How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab

How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab For questions and details contact Dennis at dennis@emitestlab.com Introduction The CE mark (an acronym for the French

More information

Lawnmowers (pedestrian controlled, battery powered)

Lawnmowers (pedestrian controlled, battery powered) Compliance Guide Rev.01, Edition 04/2018 Lawnmowers (pedestrian controlled, battery powered) European Garden Machinery Federation EGMF Bd Reyers 80, 1030 Brussels, Belgium secretariat@egmf.org +32 2 206

More information

Shipboard incinerators with capacities up to 4000 kw

Shipboard incinerators with capacities up to 4000 kw STANDARD FOR CERTIFICATION No. 2.9 Approval Programmes Type Approval Programmes for Marine Equipment Directive (MED) No. 431.90 - MED A.1/2.7 Shipboard incinerators with capacities up to 4000 kw JANUARY

More information

GUIDANCE DOCUMENT ON THE ATEX DIRECTIVE TRANSITION FROM 94/9/EC TO 2014/34/EU

GUIDANCE DOCUMENT ON THE ATEX DIRECTIVE TRANSITION FROM 94/9/EC TO 2014/34/EU EUROPEAN COMMISSION Directorate-General for Internal Market, Industry, Entrepreneurship and SMEs Industrial Transformation and Advanced Value Chains Advanced Engineering and Manufacturing Systems GUIDANCE

More information

Instruction Manual. CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications. 3 rd Edition 05/2007

Instruction Manual. CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications. 3 rd Edition 05/2007 CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications 3 rd Edition www.emersonprocess.com CAT 100 & CAT 200 Addendum for Hazardous Area Applications ESSENTIAL INSTRUCTIONS

More information

Consumer Protection: Standardized International Product Labels: 2. Scope of Labelling

Consumer Protection: Standardized International Product Labels: 2. Scope of Labelling Austria 1883 OVE was founded in Austria. Austrian market. Belgium CEBEC was founded in 1923. The CEBEC mark is particularly asked for by Belgian consumers. France AFNOR is a private, state-approved association

More information