OX100/OX102. Limiting-current type Oxygen Analyzer. Bulletin 11M10A01-03E
|
|
- Maude Caldwell
- 5 years ago
- Views:
Transcription
1 / Oxygen Analyzer Bulletin MA-3E
2 A Compact Environmental Oxygen Anal yzer with the usual Yokogawa reliability MODEL MODEL Alarm Calibration keys holder: 7 mm (* ) dia. or G3/8 Plastic sensor holder (Specify Option code /J or L98LA (* 3) ) plus cable: 5 m (), 5, or 3 m () : When mount in 7 mm hole in panel, panel thickness can be up to 4 mm. 2 : Within 5 cm of sensor tip, can reach 25 C. 3 : Specify Option code /S, or K9424DB, for metal nipple. (* 2) and sensors are not interchangeable Low range to ppm Autoranging in four ranges from - ppm to -25% High and Low Alarms N2 reflow furnaces Semiconductor maker environmental monitoring ppm-level O2 measurement Monitoring purity of N2, Ar separated from air Monitoring for deficiency of O2 Oxygen concentration FAIL lamp High, Low Alarm lamps Fixed-range 4-2 ma / -5 V, Autorange 4-2 ma, keys Enhanced Oxygen Analyzer Applications. to 25% between to.% and to 25% other than to, ppm to, ppm Validates parameter entry Main applications Globe box (processing crystal parts) Globe box (in research lab.) N2 reflow furnace / auto soldering Clean room Aging machine Monitoring for deficiency of O2 Foodstuffs Measurement cautions Usage cautions Box is to be filled with inert gas If organic solvents in box, use sampling unit Use sampling unit, remove alcohol / flux from furnace Use sampling unit if organic solvents present High temperatures, so use metal nipple K9424DB Use with Hi/Lo Alarms, or -3 (Lo) Use sampling unit if disinfectant is alcohol-based * : should not be exposed to silicone vapor, silicon gas. * 2 : Corrosive or flammable gases, halogens, Freon, or organic solvents may adversely affect sensor. Spans ppm to 25% Autoranging in two ranges, - ppm and -25% High Alarm or Low Alarm (depends on specification) Development lab., globe box Clean room for testing, environment, fermentation, biochemical Continuous monitoring of gas flow in food packing Aging machine High alarm or Low alarm lamp (depends on specification) Oxygen concentration Calibration air flow lamp Lit during alarm setting Alarm setting key Mode switching key General-Purpose Oxygen Analyzer Applications Fail lamp Units (% or ppm) to, ppm not when range is to 25% Lit during to ppm calibration Entry setting key Example: N2 reflow furnace Temperature : 2-3 C Gas flow : m/sec. Environment : Alcohol / Rosin / Flux, Oxygen ppm Compared with oxygen meter it replaced, Response was faster, so changes were quickly detected Easy maintenance for Sampling unit (easy replacement of filter, activated carbon) 5 Oxygen ppm Fast response Approx. 6 sec. A oxygen analyzer B Installed oxygen analyzer A Difference Example: Measuring oxygen concentration in welding furnace Temperature : Room temperature, atmospheric pressure Gas flow : 3 NL/min. (N2) Environment : Oxygen about 5 ppm in N2 Low oxygen concentration in furnace: safety precautions required can detect atmospheric air leakage into furnace which causes oxygen to rise to 2 ppm, so can help with welding quality assurance. Oxygen ppm 2 ppm Air leak 5 2 mm/hr B A A oxygen analyzer B Dew point measurement Solder flux flow start B / / 2
3 EXTERNAL DIMENSIONS EXTERNAL DIMENSIONS Convertor Convertor 26.2 Bracket (Parts : B9877BA) (22) ~ Panel thickness Weight : Approx.6 kg Panel cut dimension 89 + Other instrument 55 Min. space for multiple installation * * : Allow the minimum clearance of 5 mm for removable installation Other instrument 55 * Weight : Approx.2 kg * : Allow a minimum distance of 5 mm for ease of removal. Panel cut dimension Min. space for multiple installation (9) 8 (5) ø8± * Temp. 25 C Max. Temp. 5 C Max. Temp. 7 C Max. * Max temp. 7 C when plastic nipple (option code "/J" or P/N L98LA) is used. External Dimension L (m) D-sub 5 pin Male Code - L (m) / / 4
4 Sampling unit (K9424GA) 25 x 272 x 4 (mm), approx 4.8 kg Measurement gas inlet Measurement gas outlet Sampling Unit (K9424GA) Sample inlet (Rc /4) Sample outlet (Rc /4) Activated carbon filter Sampling unit (K9424GA) 2 3 Activated charcoal, 4 Flow membrane filter meter Needle valve Membrane filter: removes dust / mist / flux 2 Pump -24 V AC,.2 A 3 Activated charcoal, membrane filter: remove organic solvents 4 Flow meter:. to liters / min. Flowmeter Calibration Kit (K9424JA, JB) Gas vent tube ø75 Pressure gage Approx. 8 (9) Filter (22) Pump Power line switch Connector to joint sensor (ø8) Approx. 3 Power line connector ( 24 ) ( 36 ) ( 46 ) ( 29 ) connector Operating conditions: Atmospheric pressure, gas temperature to 4 C Mounting Rc /4 Power -24 V AC Needle valve / (3) K9424JC NEEDLE VALVE ASSY With Pressure gage and Capillary /8 Rc Piping connection for K9242JD Standard gas cylinder Pressure meter (flow adjustment) Gas outlet cock (K9424JC, JD) ppm O2/N2 Quantity 6, one-liter Calibration gas cylinder (K9424JP) Calibration kit (K9424JA, JB) Gas outlet cock + Qty. 6, one Calibration gas cylinder - 2 x 75 x 335 mm, approx 8 g. Standard Gas ( 6 cylinders ) (255) Standard Specifications Meas. principle Sampling Sample gas condition Measured gas Mounting Meas. ranges Repeatability Calibration Fine tune mode Analog output Contact output Alarm output Self-diagnostics Storage environment Converter size Meas. principle Sampling Sample gas condition Measured gas Mounting Meas. ranges Repeatability Standard Specifications Natural diffusion Temperature - 7ºC, Humidity - 8% RH (dew free), Pressure 3 ± 4 hpa (Abs) O2 in N2 or mixed gases; cannot be used with silicone vapor, combustible gases or organic solvents Indoor, panel mounting - ppm / - ppm / - ppm / -25%, automatic / fixed switching mode ±5 ppm (Meas. range : 2- ppm), ±25 ppm (Meas. range : - ppm), ±.3% of reading (Meas. range : -5 ppm), ±7.5% of reading (Meas.range : 5- ppm), ±.25% (Meas. range : -25%). Atmospheric pressure calibration (between 5 to 25% O2) 2. ppm calibration (between 8 and 2 ppm) 3. ppm calibration (between 9 and ppm) 4. 9 ppm calibration (between 85 and 95 ppm) 5. Atmospheric pressure, 2,, 5, and 9 ppm calibration The measuring value can be adjusted to true analyzed value ma DC isolated, fixed range (-, -, - ppm, -25% selectable), or 4-2 ma DC autoranging V DC, fixed range (-, -, - ppm, -25% selectable) 3. Zone signal output for 4-2 ma DC autoranging Two outputs, rated V AC, 24 V DC, A Hi or Lo alarm, sensor disconnected alarm Hi or Lo alarm. setting range : ppm to 24.9%. disconnected and converter temperature to 7 C (dew free) -24 V AC ±%, 5/6 Hz 5 VA x x 9 mm Natural diffusion Temperature - 7 C, Humidity - 8% RH (dew free), Pressure 3 ± 4 hpa (Abs) O2 in N2 or mixed gases; cannot be used with silicone vapor, combustible gases or organic solvents Indoor, panel mounting to ppm, to 25% (measuring range autoswitching) ±5% of span (for - ppm range, with O2 being in the range to ppm). ±2% of span (for - ppm range, with O2 being in the range to ppm). ±2% of span (for to 25% range). Calibration. Atmospheric pressure calibration (between 5 to 25% O2) 2. ppm standard gas calibration (95±5 ppm) Analog output 4-2 ma DC isolated, fixed range (- ppm or -25%), (for -25%, 4 ma DC corresponds to 5 ppm or less). Contact output Two outputs, rated 25 V AC, A Hi or Lo alarm, sensor disconnected alarm Alarm output High alarm contact output if concentration abnormal Hi or Lo alarm (depending on specification), setting range : ppm to 24.9% Self-diagnostics disconnected Storage environment and converter temperature to 7 C (dew free) V AC ±%, 5/6 Hz, 5 VA Converter size x x 9 mm measuring principles, measured gas, and system configuration are same as for If you want an oxygen (concentration) control range of 5 to 45 ppm, select the. K9424JD NEEDLE VALVE ASSY Approx. 34 Restrictions Can't be used in flammable or exhaust gas, corrosive gas, or organic solvent environment To use in an environment with organic silicone, flow furnace, or N2 reflow furnace: () Use a sampling unit (K9424GA), Can't use the -. (2) The maintenance requirements (filter and activated charcoal) depend on the measured gas. Be sure to read the manual and follow the safety precautions in it. 5 / / 6
5 Oxygen Analyzer Suffix Code Option Code Measuring range N Manual J E Option code* /S /J Enhanced Oxygen analyzer -//, ppm / -25% O2 With sensor (5 m; sensor assembly. m + cable 4 m) With sensor ( m; sensor assembly. m + cable 9 m) With sensor (3 m; sensor assembly. m + cable 29 m) Without sensor assembly Japanese English Metal sensor holder Plastic resin sensor holder *Standard Product does not have a sensor holder. To get the sensor holder, specify " /S " or " /J". (If using Sampling Unit, the sensor holder is not required.) Oxygen Analyzer Suffix Code Option Code Application General purpose Oxygen Analyzer Oxygen Analyzer (Can't use an activated carbon filter)* For (N2) reflow furnace (Specify in case of using an activated carbon filter)* Monitoring for deficiency of Oxygen with low alarm, Measuring range -25% Measuring Range - ppm / -25% O2 5 V AC ±%, 5/6 Hz N assy. cable 3 m + extension 2 m Without sensor assembly Manual J E Japanese English L98LA plastic resin sensor holder is provided as standard accessory. * For measurement in the range of 5 to 45 ppm, use the. Sampling unit, Calibration kit Part No. K9424GA Sampling unit K9424JA Calibration kit: Six -liter gas cylinder, gas outlet cock (with flow adjuster) K9424JB Calibration kit: Six -liter gas cylinder, gas outlet cock (without flow adjuster) Accessories Part No. K9424GY K9424JC K9424JD K9424JP K9424BA K9424CA B9877BA K9424LA K9424LB K9424LC K9424LD K9424DB L98LA Activated charcoal element, five per pack: for sampling unit Gas outlet cock (with flow adjuster): qty. one Gas outlet cock (without flow adjuster): qty. one Standard gas cylinder ( ppm O2/N2) : qty. six assy. cable 3 m for only Extension cable, 2 m: for only Bracket for mounting, two per set. assy. One per set : for only Extension cable, 4 m: for only Extension cable, 9 m: for only Extension cable, 29 m: for only holder (metal) for or holder (plastic) for or Synaptic Business Automation creates sustainable value by connecting everything in our customers organization. To realize this, Yokogawa integrates its business and domain knowledge with digital automation technologies, and co-innovates with customers to drive their business process transformation. Trademarks All brand or product names of Yokogawa Electric Corporation in this document are trademarks or registered trademarks of Yokogawa Electric Corporation. All other company brand or product names in this bulletin are trademarks or registered trademarks of their respective holders. YOKOGAWA ELECTRIC CORPORATION World Headquarters 9-32, Nakacho 2-chome, Musashino-shi, Tokyo 8-875, JAPAN Represented by: YOKOGAWA CORPORATION OF AMERICA YOKOGAWA EUROPE B.V. YOKOGAWA ENGINEERING ASIA PTE. LTD. YOKOGAWA CHINA CO., LTD. YOKOGAWA MIDDLE EAST & AFRICA B.S.C.(c) ANA-E Subject to change without notice. [Ed:6/b] Printed in Japan, 89(KP) All Rights Reserved, Copyright 2, Yokogawa Electric Corporation.
OX100, OX102. Limiting-current type Oxygen Analyzer OX100, OX102. Bulletin 11M10A01-03E
Limiting-current type Oxygen Analyzer OX00, OX02 OX00, OX02 Limiting-current type Oxygen Analyzer One Instrument measures 00 ppm to 25% Oxygen Simple "One Touch" Calibration Self Diagnostics Assure High
More informationIntelligent ph Converter PH400G. PH400G Intelligent ph Converter. Bulletin 12B7C1-01E.
Intelligent ph Converter PH400G PH400G Intelligent ph Converter Bulletin 12B7C1-01E www.yokogawa.com/an/ Places a multitude of functions at your fingertips EXA PH Intelligent ph Converter (Model PH400G)
More informationGeneral Specifications
General Specifications Model OX400 Low Concentration Zirconia Oxygen Analyzer The OX400 is a highly accurate and reliable low-concentration zirconia oxygen analyzer that is capable of measuring a wide
More informationFAST/TOOLS. Alarm System Performance Analysis (ASPA) Bulletin 50A01A00-02EN
FAST/TOOLS Alarm System Performance Analysis (ASPA) Bulletin 50A01A00-02EN FAST/TOOLS Alarm System Performance Analysis (ASPA) is essential for improved safety and continuity of production across many
More informationPersonal ph, ph/orp, Conductivity Meters
Personal ph, ph/orp, Meters PH71/PH72/SC72 Personal ph, ph/orp, Meters Bulletin 12B03D01-01E www.yokogawa.com Compact and lightweight 220g IP67 Waterproof CE,C-tick Compliance Various Convenient Functions
More informationPersonal ph, ph/orp, Conductivity Meters
Personal ph, ph/orp, Meters PH71/PH72/SC72 Personal ph, ph/orp, Meters Bulletin 12B03D01-01E www.yokogawa.com/an/ Compact and lightweight 220g IP67 Waterproof CE,C-tick Compliance Various Convenient Functions
More informationPersonal ph, ph/orp, Conductivity Meters PH71/PH72/SC72
Personal ph, ph/orp, Meters PH71/PH72/SC72 Personal ph, ph/orp, Meters Bulletin 12B03D01-01E www.yokogawa.com/ Compact and lightweight 220g IP67 Waterproof Various Convenient Functions Data memory Alarm
More informationNew Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.
The Process TDLS Solution New Features TDLS 200 Tunable Diode Laser Spectroscopy (TDLS) Analyzer Bulletin 11Y01B01-01E-A www.yokogawa.com/an/index.htm The first Tunable Diode Laser analyzer Innovative
More informationGeneral Specifications
eneral Specifications DO70 Optical Dissolved Oxygen Sensor EERA DO70 optical dissolved oxygen sensor is designed for using in water treatment plants such as sewage treatment works and effluent activated
More informationSeries 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased
TELEDYNE Series 3300 Unaffected by hydrocarbons, H2, or CO2 Easy to handle, inexpensive, and easy to replace Can apply to ppb, ppm, and percent ranges Trace & Percent Oxygen Analyzers Fuel Cell Zirconium
More informationGeneral Specifications
General Specifications Model GD402 Gas Density Meter Overview The Model GD402 gas density analyzer and Model GD40 detector not only provide continuous measurement of gas density, but also several other
More informationGeneral Specifications
General Specifications Model DM8 Vibration Type Liquid Density Meter Overview In 1967, YOKOGAWA developed the Model VD6 Vibration Type Liquid Density Meter in response to user requests for an online density
More informationMEMS Carbon Monoxide Gas Sensor. (Model No.:GM-702B) Manual. Version: 1.1. Valid from: Zhengzhou Winsen Electronics Technology Co.
MEMS Carbon Monoxide Gas Sensor (Model No.:GM-702B) Manual Version: 1.1 Valid from: 2017.11.23 Zhengzhou Winsen Electronics Technology Co., Ltd Statement This manual copyright belongs to Zhengzhou Winsen
More informationSPECIFICATION SHEET. SLC-1615 (for low concentration) SLC-1625 (for high concentration) SILICA ANALYZER
ISO-14001 ISO-9001 SPECIFICATION SHEET SILICA ANALYZER Model: SLC-1605 (for very low concentration) SLC-1615 (for low concentration) SLC-1625 (for high concentration) This equipment is used for high accuracy
More informationStandard SPECIFICATIONS FEATURES APPLICATIONS
SPECIFICATIONS PC Board Mountable Pressure Sensor 0-50 mv Output Voltage Excitation Gage, Absolute, and Differential Temperature Compensated FEATURES Dual-in-Line Package 0ºC to 50ºC Compensated Temperature
More informationGeneral Specifications
General Specifications GD402, GD40 Gas Density Meter GS 11T3E101E Overview The Gas Density Meter consists of gas density converter GD402 and gas density detector GD40. The Model GD402 gas density converter
More informationDF-340E PROCESS ANALYZERS APPLICATIONS FEATURES
PROCESS ANALYZERS DF-340E The DF-340E is a Coulometric sensor based oxygen analyzer suitable for outdoor installation and designed to measure trace oxygen and percent level in pure and multigas backgrounds.
More informationpre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M
PHOTOELECTRIC SENSORS EFA/B_-F Special family with inverted output logic Fully compatible with previous EF family Simple installation due to compact format Wide variety of models Ordering Information EFA/B
More informationPulp & Paper Solution. Pulp & Paper Solution. Instruments and Solution for Pulp & Paper Industry LF3BUSS03-00EN.
Pulp & Paper Pulp & Paper Instruments and for Pulp & Paper Industry LF3BUSS03-00EN www.yokogawa.com Pulp & Paper Plant for the World Process for Fundamental Materials, Requires Effective Production with
More informationOIL FILM DETECTOR (Flame-proof Version) SODL-1600
OIL FILM DETECTOR (Flame-proof Version) SODL-600 The model SODL-600 is a flame-proof type oil film detector. This model monitors a water surface for the presence of an oil film floating on the surface.
More informationGeneral Specifications
General Specifications Model GD402 Gas Density Meter GS 11T3E101E Overview The Model GD402 gas density converter and Model GD40 detector not only provide continuous measurement of gas density, but also
More informationProcess Gas Chromatograph
Process Gas Chromatograph The GC1000 Mark2offers two new process gas chromatographs: the Isothermal Oven type which sets new standards for easy operation and reliable performance; and the Programmed-Temperature
More informationSPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001
ISO-14001 ISO-9001 SPECIFICATION SHEET ORGANIC POLLUTION MONITOR Model: OPM-410A The Model OPM-410A monitors organic pollution in water from industrial effluent, rivers etc.. The design and construction
More informationTwo global companies, one solution.
Two global companies, one solution. About the Partnership March 2002, Yokogawa Electric Corportation, Japan and Pepperl+Fuchs Germany signed a Global Preferred Vendor Agreement. Solutions found in this
More informationDew-Point Transmitters and Instruments
Dew-Point Transmitters and Instruments Reliable moisture measurement for critical process control Moisture Measurement and Analysis Michell Instruments sensors provide accurate and reliable moisture measurement
More informationModel OEM-2 INSTRUCTIONS FOR USE
ECO SENSORS, INC. 3-03.2 OEM OZONE CONTROLLER Model OEM-2 INSTRUCTIONS FOR USE GENERAL The model OEM-2 is a system to control ozone generators and alarms based on an adjustable ozone concentration set
More informationESD Safe UL Approved INSTRUCTIONAL MANUAL EX V EX V TEMPERATURE CONTROLLED SOLDERING STATION
ESD Safe UL Approved INSTRUCTIONAL MANUAL MODEL PART NUMBER EX-685 110V 0685-0000 EX-685 220V 0685-2000 TEMPERATURE CONTROLLED SOLDERING STATION AUTOMATED PRODUCTION EQUIPMENT 3661 Horseblock Road, Medford,
More informationSAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications
SAFETY MANUAL Intelligent Sensors for H 2 S Gas Applications The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically
More informationUser s Manual. Model VJRK IM 77J01R21-01E 1. CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT 4. MODEL AND SUFFIX CODES 5.
User s Manual Model VJRK Limit Alarm (RTD for RTD Input Input Type) IM J01R21-01E 1. CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT This user s manual should be carefully read before installing and operating
More informationM5200 Industrial Pressure Transducer
SPECIFICATIONS Wide Temperature Range Compact Variety of Pressure Ports and Electrical Configurations Optional Stainless Steel Snubber CE Compliant and Weatherproof UL Certified Gage, Sealed, Compound
More informationSafe Operation Manual. Honeywell IQ Force Gas Detector
Safe Operation Manual Honeywell IQ Force Gas Detector Honeywell Analytics 800-663-4164 403-248-9226 Fax 403-575-3708 03JUN2012 P/N 50105843-047 Version 01 http://www.honeywell.com HONEYWELL IQ Force PERSONAL
More informationU5300 Industrial Pressure Transducer
FEATURES Heavy Industrial CE Approval 10 V/m EMI Protection Reverse Polarity Protection on Input Short Circuit Protection on Output ±0.1% Accuracy ±0.5% Total Error Band Compact Outline -40 C to +125 C
More information85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage
FEATURES Weldable and Threaded Process Fittings -40ºC to +125ºC Operating Temperature ±0.1% Pressure Non Linearity Solid State Reliability APPLICATIONS Medical Instruments Process Control Fresh & Waste
More informationUser's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT
User's Manual Model VJQ8 Pulse to Analog Converter (Multi-function) (Isolated Single-output and Isolated Dualoutput Types) Thank you for purchasing the JUXTA Signal Conditioner. Please read through this
More informationGeneral Specifications
General Specifications GS J0H-0E Model MVHK Digital Limit Alarm (DC Type) with Active Color PV Display General This plug-in type Digital Limit Alarm for DC input receives DC current or DC voltage signal.
More information86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated
SPECIFICATIONS 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature The 86 compensated is a small profile, media compatible, piezoresistive silicon pressure sensor packaged
More informationAir-Quality Detection Module. User s Manual
Air-Quality Detection Module (Model:ZP01-MP503) User s Manual Version: 1.4 Valid from 2014-11-01 Zhengzhou Winsen Electronics Technology Co., Ltd ISO9001 Certificated Company Statement This manual s copyright
More informationModel C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments
Model C-380 Refrigerant Leak Detector Instruction Manual reedinstruments www 1-877-849-2127 info@reedinstruments. www.reedinstruments. Table of Contents Safety... 3 Features... 3 Specifications... 4 Instrument
More informationMS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost
SPECIFICATIONS PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost The MS1471 is a piezoresistive silicon pressure sensor packaged in a surface mount configuration. It is intended
More informationSmoke Sensor. (Model:MQ-2) Manual. Version: 1.4. Valid from: Zhengzhou Winsen Electronics Technology Co., Ltd
Smoke Sensor (Model:MQ-2) Manual Version: 1.4 Valid from: 2015-03-10 Zhengzhou Winsen Electronics Technology Co., Ltd Statement This manual copyright belongs to Zhengzhou Winsen Electronics Technology
More informationGeneral Specifications
General Specifications Model A2NN30D Node Interface Unit (for N-IO) GENERAL The Node Interface Unit (NIU) has an interface function that allows a Field Control Unit (FCU) to communicate with an I/O unit
More informationSeries 9000 Total Hydrocarbon Analyzer
Series 9000 Total Hydrocarbon Analyzer Analyzer The Baseline Series 9000 is the candidate of choice whenever accurate, reliable total hydrocarbon analysis is required. The Series 9000 analyzer provides
More informationair.iq Moisture Analyzer Packaged Solution GE Measurement & Control Applications Features
GE Measurement & Control air.iq Moisture Analyzer Packaged Solution Features Applications air.iq simplifies the selection and installation of your moisture analyzer. Install the moisture probe, wire your
More informationCatalytic Flammable Gas Sensor. (Model: MC105B) User s Manual. Version: 1.3. Valid from: Zhengzhou Winsen Electronics Technology Co.
Catalytic Flammable Gas Sensor (Model: MC105B) User s Manual Version: 1.3 Valid from: 2014-05-01 Zhengzhou Winsen Electronics Technology Co., Ltd Statement This manual copyright belongs to Zhengzhou Winsen
More informationAir-Quality Detection Module. User s Manual
Air-Quality Detection Module (Model:ZP07-MP901) User s Manual Version: 1.1 Valid from 2014-11-10 Zhengzhou Winsen Electronics Technology Co., Ltd Statement This manual s copyright belongs to Zhengzhou
More informationCompact Ultra Low Temperature Chamber
Compact Ultra Low Temperature Chamber MC-712R 812R CAT.NO.E14140-Z1804 High performance and reliability come in a compact package, covers wide range of temperature testing needs, from ultra-low temperature
More informationCustomized Industrial Products
Customized Industrial Products Product Catalog Large Walk-in Type Drying Oven Large Size Autoclave Large Size Fine Oven Targeting Productivity Improvement Yamato offers customization of products based
More information316L SS Pressure Sensor High Pressure 0-100mV Output Absolute
SPECIFICATIONS 316L SS Pressure Sensor High Pressure 0-100mV Output Absolute The 89 uncompensated is a small profile, media compatible, piezoresistive silicon pressure sensor packaged in a 316L stainless
More informationUser s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN.
User s Manual AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type Contents 1. ATEX Documentation 2. Explosion Proof Type Instrument 2.1 ATEX...2 2.2 IECEx...7 1 2 Integral
More informationProcess Control PIP PCEA001 Fixed Gas Detection Guidelines
November 2015 Process Control PIP PCEA001 PURPOSE AND USE OF PROCESS INDUSTRY PRACTICES In an effort to minimize the cost of process industry facilities, this Practice has been prepared from the technical
More informationMODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING
MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING FOR OPERATION FROM 115 AC POWER Andersen Medical Gas 12 Place Lafitte Madisonville, LA 70447 http://www.themedicalgas.com 1-866-288-3783
More information85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated
SPECIFICATIONS 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature The 85 compensated is a small profile, media compatible, piezoresistive silicon pressure sensor packaged
More informationEssential Equipment for Advanced Laboratory Use. Rotary Evaporator TOKYO RIKAKIKAI CO., LTD.
Essential Equipment for Advanced Laboratory Use. Rotary Evaporator TOKYO RIKAKIKAI CO., LTD. N-1001 series Rotary Evaporator Quality design with broad versatility Economic and durable Rotary Evaporator
More informationMSP340 Pressure Transducer
Shown with Packard Connector Shown with Packard Connector MSP40 SPECIFICATIONS Low Cost OEM 100% Leak Proof No O-Rings No Silicon Oil No Welds FEATURES One-Piece Stainless Steel Construction Ranges up
More informationUsing the Model 1500 Portable Chilled Mirror Hygrometer
APPLICATION NOTE 2016_0120 MODEL 1500 Rev C Using the Model 1500 Portable Chilled Mirror Hygrometer The Model 1500 is a portable, multi-function, optical chilled mirror hygrometer designed to accurately
More informationGeneral Specifications
General Specifications Model S2NN30D Node Interface Unit (for N-IO) GS 32P06F20-01EN GENERAL The Node Interface Unit (NIU) has an interface function that allows a Safety Control Unit to communicate with
More informationDräger PIR 3000 Detection of flammable gases and vapours
Dräger PIR 3000 Detection of flammable gases and vapours The Dräger PIR 3000 is an explosion proof infrared gas detector for continuous monitoring of combustible gases and vapors Based on a stainless steel
More informationDräger PointGard 2100 Detection of toxic gases and vapours
Dräger PointGard 2100 Detection of toxic gases and vapours The Dräger PointGard 2100 series is a self-contained gas detection system for the continuous area monitoring of toxic gases in ambient air PointGard
More informationER-TF SERIES. Wide-area Ionizer Steady-state DC Method. Slim in shape, Wide in charge removal area, An evolutionary form in expression.
117 Wide-area Ionizer Steady-state DC Method SERIES Related Information General terms and conditions... F-3 Glossary of terms... P.191 No compressed air necessary guide... P.11~ General precautions...
More informationOzone Gas Sensor. (Model:MQ131 High Concentration) Manual. Version: 1.4. Valid from: Zhengzhou Winsen Electronics Technology Co.
Ozone Gas Sensor (Model:MQ131 High Concentration) Manual Version: 1.4 Valid from: 2015-03-10 Zhengzhou Winsen Electronics Technology Co., Ltd Statement This manual copyright belongs to Zhengzhou Winsen
More informationSensirion Sensor Solutions. Humidity and Temperature Liquid Flow Gas Flow Differential Pressure
Sensirion Sensor Solutions Humidity and Temperature Liquid Flow Gas Flow Differential Pressure Sensirion The Sensor Company A Leading Sensor Manufacturer Sensirion AG is an international sensor company
More information154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES
SPECIFICATIONS Low Cost 316L Stainless Steel or Titanium 19mm Diameter Package 0-100mV Output Gage and Absolute Wide Compensated Temperature Range FEATURES O-Ring Mount -20ºC to +85ºC Compensated Temperature
More informationRefrigerated Air Dryer
Refrigerated Air Dryer For Use in Europe, Asia and Oceania Applicable for the high-temperature environments Ambient temperature : Max. 45 C Inlet air temperature : Max. 65 C Air flow capacity * IDFA90-23,
More informationCatalytic Gas Sensor. (Model: MC113/ MC113C) Manual. Version: 1.3. Valid from: Zhengzhou Winsen Electronics Technology Co.
Catalytic Gas Sensor (Model: MC113/ MC113C) Manual Version: 1.3 Valid from: 2014-05-01 Zhengzhou Winsen Electronics Technology Co., Ltd Statement This manual copyright belongs to Zhengzhou Winsen Electronics
More informationSIL 2. Ultima X Series Gas Monitors CERTIFIED
Ultima X Series Gas Monitors 5 Now with SIL 2 CERTIFIED Products Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection
More information86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated
Compensated SPECIFICATIONS 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated The 86 compensated is a small profile, media compatible, piezoresistive silicon
More informationGeneral Specifications
General Specifications Model S2NN30D Node Interface Unit (for N-IO) GS 32P06F20-01EN GENERAL The Node Interface Unit (NIU) has an interface function that allows a Safety Control Unit to communicate with
More information82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated
SPECIFICATIONS 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated The 82 constant voltage is a 19 mm small profile, media compatible, piezoresistive
More informationMark 25 Ultrapure Water Conductivity Analyzer
Martek Instruments, Inc. Mark 25 Ultrapure Water Conductivity Analyzer Instruction Manual WARRANTY POLICY Unless otherwise stated, MARTEK INSTRUMENTS, INC. warrants this equipment to be free from defects
More informationEconomical Lead Free Reflow Oven Series
Best Choice To Go With Small Volume Production E-THERM E4/E6 Lead Free Reflow Oven Economical Lead Free Reflow Oven Series E4/E6 is a capable lead free CE certificated reflow oven with 4/6 upper & 4/6
More informationIN-SITU ZIRCONIA OXYGEN ANALYZER <HART communication>
DATA SHEET IN-SITU ZIRCONIA OXYGEN ANALYZER ZFK8, ZKM-2, ZTA This oxygen analyzer is used to continuously measure oxygen concentration in combustion exhaust gas of industrial boilers
More informationAmmonia Gas Sensor. (Model:MQ137) Manual. Version: 1.4. Valid from: Zhengzhou Winsen Electronics Technology Co., Ltd
Ammonia Gas Sensor (Model:MQ137) Manual Version: 1.4 Valid from: 2015-03-10 Zhengzhou Winsen Electronics Technology Co., Ltd Statement This manual copyright belongs Zhengzhou Winsen Electronics Technology
More informationSensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications
Sensepoint The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a high quality, low cost solution to their industrial gas monitoring needs. Sensepoint Fit For Purpose Flammable,
More information5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors
Ultima X Series Gas Monitors Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection methods. HART Protocol is now
More information154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.
SPECIFICATIONS Low Cost 316L Stainless Steel or Titanium 19mm Diameter Package 0-100mV Output Gage and Absolute Wide Compensated Temperature Range The 154BC is a 19mm small profile, media compatible, piezoresistive
More information6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment
CONTENT Page 1. GENERAL INFORMATION ------------------ 2 2. FEATURES ---------------------------------------- 2 3. SPECIFICATION --------------------------------- 3 4. OPERATION GUIDE ---------------------------
More informationNet Safety ST3 XChem Toxic Gas Sensor
Product Data Sheet 00813-0100-4303, Rev AA Net Safety ST3 XChem Toxic Gas Sensor Millennium II Series Sensors Net Safety ST3 Overview The Net Safety ST3 XChem series of electrochemical toxic gas sensors
More information89BSD Digital Output
SPECIFICATIONS Stainless Steel with O-Ring Seal Pressure/Temperature Read-Out (24-bit DS ADC) ASIC Calibrated Absolute, Sealed Gage 9mm Diameter The 89BSD is a 9mm diameter small profile, media compatible,
More informationDräger Polytron 5200 CAT Detection of flammable gases and vapours
Dräger Polytron 5200 CAT Detection of flammable gases and vapours The Dräger Polytron 5200 CAT is a cost-effective explosion-proof transmitter for the detection of flammable gases in the lower explosion
More informationFLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS.
SERVOTOUGH FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS Flexible Can be used in hazard rated locations including Zone
More informationWH EN IGH T T C LO SED
AR EA kajdfkjl; lkjdflkjal; ldkfj;alk alskjdf ;lsdkf 7079 ph/orp Transmitter 70-82-03-08 1/97 Page 1 of 5 Specification Overview The 7079 ph/orp Transmitter is designed for chemical process industry applications
More informationU86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS
SPECIFICATIONS Mountable with O-ring seal Stainless Steel wetted surfaces Amplified ASIC calibrated Absolute, sealed gage Cable option Analog output SENT Output Optional (contact factory for details) FEATURES
More informationSub psi SPECIFICATIONS
SPECIFICATIONS PC Board Mountable Pressure Sensor 40 mv Output Typical Differential Pressures Metal Tube and Ceramic Barbed Ports Temperature Compensated The 1210 sub PSI is a temperature compensated,
More information86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated
Compensated SPECIFICATIONS 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated The 86 compensated is a small profile, media compatible, piezoresistive silicon
More informationManual No.'13 SAF-T-182. updated December 02,2013 TECHNICAL MANUAL AIR TO AIR HEAT EXCHANGE UNIT SAF150E6 250E6 350E6 500E6 650E6 800E6 1000E6
Manual No.'13 SAF-T-182 updated December 02,2013 TECHNICAL MANUAL AIR TO AIR HEAT EXCHANGE UNIT SAF150E6 250E6 350E6 500E6 650E6 800E6 1000E6 CONTENTS 1. SELECTION DATA... 2 1.1 Specifications... 2 1.2
More informationCLARITY II TURBIDIMETER
Product Data Sheet PDS 71-T1055/rev.J January 2006 Model T1055 CLARITY II TURBIDIMETER COMPLETE SYSTEM includes single or dual input analyzer, sensor(s), and debubbler assembly CHOOSE U.S. EPA METHOD 180.1
More informationROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A
SPECIFICATIONS (Revised 1/12/2006) ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A The system shall operate on the principle of light absorption. It shall consist
More informationRefrigerated Air Dryer
Refrigerated Air Dryer Applicable for the high-temperature environments Ambient temperature : Max. 45 C Inlet air temperature : Max. 65 C Air flow capacity * IDF90-20, Dew point of 10 C, 60 Hz 16.4 m 3
More informationInterscan Corporation. Instruction Manual Series Compact Portable Analyzer
Interscan Corporation Instruction Manual 4000 Series Compact Portable Analyzer 1 2 INTERSCAN CORPORATION Simplified 4000 SERIES MANUAL TABLE OF CONTENTS SECTION TITLE PAGE 1.0 Equipment Description 4 2.0
More informationCO 2 Laser. High Reliability and Performance
CO 2 Laser High Reliability and Performance FANUC imagination at work Drives & Motors Quality Through Innovation GE Fanuc is a world leader in CNC technology and has long-term experience in developing
More informationDräger Bump Test Station Calibration and Bump Testing
Dräger Bump Test Station Calibration and Bump Testing Easy to use, stand-alone and portable. With the Bump Test Station, functionality tests of gas detection and warning devices can be carried out easily
More informationEnvironmental simulation chamber for complex alternating climate profiles
MKF series (E3.1) Environmental simulation chambers Environmental simulation chamber for complex alternating climate profiles A BINDER environmental simulation chamber of the MKF series is ideally suited
More informationCARBON MONOXIDE CO SS SOLID STATE ELECTROCHEMICAL SENSORS
1. DESCRIPTION OF TECHNOLOGY The CO sensor is based on the technology of electrochemical gas detection principle. This technology can be used to detect chemicals or gases that can be oxidized or reduced
More informationPCMini52 Digital RH & Temperature Mini Probe User s Manual
PCMini52 Digital RH & Temperature Mini Probe User s Manual 97300 Issue 1, March 2012 Michell Instruments Inside front cover (blank) PCMini52 2009-2012 Michell Instruments This document is the property
More informationModels TX-KE and TX-KP Toxic Gas Transmitters
Models TX-KE and TX-KP Toxic Gas Transmitters Instruction Manual PureAire Monitoring Systems, Inc. 557 Capital Dr. Lake Zurich, IL. 60047 Phone: 847-726-6000 Fax: 847-726-6051 Toll-Free: 888-788-8050 www.pureairemonitoring.com
More informationImprove Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...
Improve Performance and Reduce Maintenance Costs Model Q45D Dissolved Oxygen Monitor... Why Throw Away Money? Why Throw Away Money? ATI s Model Q45D Dissolved Oxygen monitor is designed to provide reliable
More informationBasic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]
Basic Board Mount Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] DESCRIPTION Honeywell s Basic Board Mount Sensors: NBP Series Uncompensated/Unamplified are low pressure
More informationSHAKING WATER BATHS ENGLISH
SHAKING WATER BATHS ENGLISH Display Technical Features Operation Easy to read Large LED temperature display for actual value and setpoint (display resolution 0.1 C) Several values at a glance Large Multi-Display
More informationNitrogen Dioxide (NO2) Single-Point Gas Detection System
Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary
More informationInstallation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E
EB99802801-1 Installation Manual RBM-PMV0363E RBM-PMV0903E Installation Manual English OUTDOOR UNIT SIDE UPPER INDOOR UNIT SIDE Thank you very much for purchasing TOSHIBA Air conditioner. Please read this
More information