For Salisbury by Honeywell

Size: px
Start display at page:

Download "For Salisbury by Honeywell"

Transcription

1 Hugh Hoagland Consulting, Inc. Electric rc Exposure Tests For Salisbury by Honeywell Hood Salisbury by Honeywell Lift Front Hood, Style LFH, Paulson Lens, Two Layers Milliken Fabric System Report Number: 110F01, Revision: 00 October 31, 01 Tests Conducted at Kinectrics High Current Laboratory Toronto, Ontario, Canada Eastpoint Park lvd Suite E, Louisville, KY 403 Phone: , Page 1 of 6

2 Electric rc Exposure Report STM F17808 Standard Test Method for Determining the rc Rating and Standard Specification for Eye or Face Protective Products General t the request of David Sklodowski electric arc exposure tests were conducted on hoods for Salisbury by Honeywell. David Sklodowski arranged with rcwear.com to facilitate testing by the High Current Laboratory of Kinectrics in Toronto and to review test data. The tests documented in this report were conducted in accordance with: STM F17808 Standard Test Method for Determining the rc Rating and Standard Specification for Face Protective Products Test Samples Hood test samples (were) received on October 1, 01. Samples were tested as received. washing or any other preparation is required by the standard. Test Results The test program includes minimum of ten twomannequin arc trials. The test data set is evaluated using logistic regression method. Following test data was recorded for each trial: arc exposure electrical conditions: arc trial number, RMS arc current, peak arc current, arc voltage, arc duration, energy dissipated in arc, plots of arc current and arc voltage temperature rise response from two monitor and four face sensors for each instrumented mannequin head in each trial, plot of Incident energy distribution Ei from bare shot analysis photographs of exposed material panels video bove mentioned test data is part of report and is available for download from rcwearonline.com arc testing website. Test data is accessible only to and protected with Salisbury by Honeywell unique password. Essential test data and test results are presented in the table below and on the attached data pages as follows: arc rating TPV or ET or both and plots of the burn injury probability (TPV) or breakopen probability (ET) or both versus Ei test specimen description and order of layers for fabric system and faceshield distance from an arc center line to the panel surface Eastpoint Park lvd Suite E, Louisville, KY 403 Phone: , Page of 6

3 subjective evaluation heat attenuation factor (HF) and plot of HF on Ei ignition probability value (if determined during testing) Rating Rating resulted from Hood arc testing is TPV = 43 cal/cm² Rating resulted from Hood Fabric System previous testing is TPV = 41.3 cal/cm² Hood system specified in the Table 1 below received final arc rating as: Customer Manufacturer, Part/Model Number General Design Layer 1 Layer Manufacturer, Design Layer 1 Material, Color, Thickness Layer 1 Material, Color, Thickness Manufacturer, Part/Model Number TPV = 41.3 cal/cm² Table 1 Salisbury by Honeywell Salisbury by Honeywell Lift Front Hood, Style LFH, Paulson Lens, Two Layers Milliken Fabric System Hood fabric system Milliken, Style S/155590L, 9 oz/yd² 306 g/m² Plain, 88% Cotton 1% Nylon, Gray Milliken, Style S/155590, 9 oz/yd² 306 g/m² Plain, 88% Cotton 1% Nylon, Navy lue Hood faceshield system Paulson Lift Front Two Layers Lens Polycarbonate, Green, Thickness 0.06 inch, mm Polycarbonate, Clear, Thickness 0.0 inch, 0.5 mm Hard Hat rth, Style 79, Class E The order of layering is numbered starting from the outer layer listed first. Requested by: David Sklodowski pproved by Hugh Hoagland rcwear.com Neither Hugh Hoagland Consulting, Inc. dba/rcwear, nor its affiliates, nor any person acting on behalf of any of them: a) makes any warranty, express or implied, with respect to the use of any information, apparatus, method, or process disclosed in this report or that such use may not infringe privately owned rights; or b) assumes any liabilities with respect to the use of, or for damages resulting from the use of, any information, apparatus, method, or process disclosed in this report Eastpoint Park lvd Suite E, Louisville, KY 403 Phone: , Page 3 of 6

4 Report # Samples Received: OCT 1, 01 K F01 Tested for Hugh Hoagland rcwear.com Phone: arctesting@arcwear.com Samples Tested: OCT 31, 01 Test Report Kinectrics Inc., 800 Kipling venue, Unit Toronto, Ontario, Canada Tel: , Contact information for item tested: David Sklodowski Salisbury by Honeywell david.sklodowski@honeywell.com ISO Test item description Salisbury by Honeywell, Lift Front Hood, Style LFH, Lens: Paulson, Outer, Thickness.06 in, Polycarbonate, Green, Inner, Thickness,.0 mm, Polycarbonate, Clear, Mounting racket: Paulson, Part WS, Transparent Chin Protector, Hardhat, rth, Style 79, Class E, Fabric: Two Layers, Milliken, Style S/155590L, 9 oz/yd² 306 g/m² Plain, 88% Cotton 1% Nylon, Gray over Milliken, Style S/155590, 9 oz/yd² 306 g/m² Plain, 88% Cotton 1% Nylon, Navy lue, rcwear# 110F01 Reference Standard STM F17808 Standard Test Method for Determining the rc Rating and Standard Specification for Eye and Face Protective Products Test Parameters: Test current: rc Gap: Distance to Fabric: 8 k 30 cm 30 cm rc Rating, TPV = 43 Cal/cm² Heat ttenuation Factor, HF = 95% Number of samples analysed: Incident Energy Range: 0 9 to 53 cal/cm² Summary The rc Rating of this material is intended for use as part of a flame resistant garment or system for workers exposed to electric arcs. The samples were tested by Kinectrics as received. The test result is applicable only to the Test Item, other material or color may have different protection level. ctual performance of the complete garment may vary depending on the final design and assembly of the garment. The rc Rating was calculated based on the data obtained and analysed in accordance with the latest version of the applicable standards. The individual test sheets, graphs, photographs of the samples and video of every test are provided in digital format to the Client for review. s of ugust 1, 010, the arc testing performed to the above mentioned Standard is accredited by the Standards Council of Canada to conform to the requirments of CNP4E (ISO/IEC 1705:005) by QMI, a division of SI Global and rth merica's leading QMS registrar. dherence to this standard provides one of the strongest assurances of service quality available. s a minimum, since July 1998 all work at Kinectrics is performed to meet the requirements of ISO Kinectrics Inc takes reasonable steps to ensure that all work performed shall meet the industry standards as set out in Kinectrics Inc.'s Quality Manual, and that all reports shall be reasonably free of errors, inaccuracies or omissions. KINECTRICS INC. DOES NOT MKE NY WRRNTY OR REPRESENTTION WHTSOEVER, EXPRESS OR IMPLIED, WITH RESPECT TO THE MERCHNTILITY OR FITNESS FOR NY PRTICULR PURPOSE OF NY INFORMTION CONTINED IN THIS REPORT OR THE RESPECTIVE WORKS OR SERVICES SUPPLIED OR PERFORMED Y KINECTRICS INC. Kinectrics Inc. does not accept any liability for any damages, either directly, consequentially or otherwise resulting from the use of this report. te The test performed does not apply to electrical contact or electrical shock hazard. n unsigned copy of this report is an unofficial reporting of information. Report must be signed to validate test data and comform Performed by: pproved by: Joe Ogrodowczyk Station Operator High Current Laboratory Ph: Claude Maurice, Lab Manager High Current Laboratory hcl@kinectrics.com Page 4 of 6

5 Date: OCT 31, 01 Report # K F01 Determination of TPV by performing logistic regression on panel burn response as indicated in Summary Table Test Performed in accordance with : STM F17808 ISO Fabric Description: Salisbury by Honeywell, Lift Front Hood, Style LFH, Lens: Paulson, Outer, Thickness.06 in, Polycarbonate, Green, Inner, Thickness,.0 mm, Polycarbonate, Clear, Mounting racket: Paulson, Part WS, Transparent Chin Protector, Hardhat, rth, Style 79, Class E, Fabric: Two Layers, Milliken, Style S/155590L, 9 oz/yd² 306 g/m² Plain, 88% Cotton 1% Nylon, Gray over Milliken, Style S/155590, 9 oz/yd² 306 g/m² Plain, 88% Cotton 1% Nylon, Navy lue, rcwear# 110F Determination of TPV Incident Energy (cal/cm²) 54 TPV = 43 cal/cm² Probability 5% 10% 0% 30% 40% 50% 60% 70% 80% 90% Ei # Pts = 0 # Pts above Stoll = 8 # Pts reakopen = 0 # Pts always >STOLL = 6 # Pts always <STOLL = 7 # Pts within 0% = 1 # Pts in mix zone = Determination of HF Data pts est Fit 95% CI HF = 95 % Confidence Intervals 95% CI = 94.5, % CI pts Incident Energy (cal/cm²) 54 Page 5 of 6

6 Date: OCT 31, 01 Report # K F01 Summary Table Test Performed in accordance with : STM F17808 ISO Fabric Description: Salisbury by Honeywell, Lift Front Hood, Style LFH, Lens: Paulson, Outer, Thickness.06 in, Polycarbonate, Green, Inner, Thickness,.0 mm, Polycarbonate, Clear, Mounting racket: Paulson, Part WS, Transparent Chin Protector, Hardhat, rth, Style 79, Class E, Fabric: Two Layers, Milliken, Style S/155590L, 9 oz/yd² 306 g/ m² Plain, 88% Cotton 1% Nylon, Gray over Milliken, Style S/155590, 9 oz/yd² 306 g/m² Plain, 88% Cotton 1% Nylon, Navy lue, rcwear# 110F01 Test # Panel Test Current Cycles of 60Hz Ei Cal/cm² SCD Cal/cm² Summary of measured energy and observations HF % urn reak Open blation fter Flame sec. Omit Comment 1 K K K K K K K K REK OPEN LENSE 9 K K NO NO URN, NOISE ON TEMPERTURE TRCE; RCKET IGNITION 11 K K K K K K K K K K REK OPEN LENSE Eastpoint Park lvd Suite E Louisville, KY 403 Phone: , Page 6 of 6

Hugh Hoagland Consulting, Inc. Electric Arc Exposure Tests. For Innovative Textiles

Hugh Hoagland Consulting, Inc. Electric Arc Exposure Tests. For Innovative Textiles Hugh Hoagland Consulting, Inc. Electric Arc Exposure Tests For Innovative Textiles Fabric system Outer Layer: 5.5 oz/yd² IUS Twill, 88% Cotton 12% Nylon, Style 341, Khaki. 6.6 oz/yd² Inner Layer: 6.5 oz/yd²

More information

Hugh Hoagland Consulting, Inc. ArcWear.com. Electric Arc Exposure Tests. for Stern & Stern

Hugh Hoagland Consulting, Inc. ArcWear.com. Electric Arc Exposure Tests. for Stern & Stern Hugh Hoagland Consulting, Inc. ArcWear.com 1566 Red Brush Road Newburgh, IN 47630 Phone: 502-314-7158 Fax: 603-457-5960 E-mail: hugh@arcwear.com Electric Arc Exposure Tests for Stern & Stern October 2002

More information

The Basics Arc Flash Protection

The Basics Arc Flash Protection 2008 The Basics Arc Flash Protection An arcing fault can be defined as the flow of current through a path where it is not intended to flow Rob Vajko 12/15/2008 What is an Arc Flash? An arc flash starts

More information

actoolsupply.com YOUR SINGLE SOURCE FOR INDUSTRIAL ELECTRICAL PROTECTION actoolsupply.com

actoolsupply.com YOUR SINGLE SOURCE FOR INDUSTRIAL ELECTRICAL PROTECTION actoolsupply.com YOUR SINGLE SOURCE FOR INDUSTRIAL ELECTRICAL PROTECTION 2014 Salisbury Honeywell SK100 pro wear arc flash clothing kit Salisbury Honeywell SK75 pro wear arc flash clothing kit Salisbury Honeywell SK55

More information

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008 Intertek I 0:: o D.. W 0:: I en w I REPORT NUMBER: 3161466SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: EVALUATION CENTER Intertek Testing Services NA Inc. 16015 Shady Falls Rd. Elmendorf,

More information

Webinar November 12, 2014

Webinar November 12, 2014 Webinar November 12, 2014 Dennis L. Mater dennis.l.mater@dupont.com FR Apparel Sales Technical Leader North America Webinar Overview Introduction Hazard Risk Types Contrast Short Duration Fire and Arc

More information

TABLE OF CONTENTS. 1.0 INTRODUCTION Scope References Test Specimen Description Summary 3

TABLE OF CONTENTS. 1.0 INTRODUCTION Scope References Test Specimen Description Summary 3 Page No. 2 TABLE OF CONTENTS Page No. 1.0 INTRODUCTION 3 1.1 Scope 3 1.2 References 3 1.3 Test Specimen Description 3 1.4 Summary 3 2.0 TEST PROCEDURES AND RESULTS 4 2.1 Wall-Mount Pull-Out Test 4 2.2

More information

ethekwini Electricity MV Switchgear flash over, and injury to staff member. Presentation to AMEU Technical Meeting Sept 2009.

ethekwini Electricity MV Switchgear flash over, and injury to staff member. Presentation to AMEU Technical Meeting Sept 2009. ethekwini Electricity MV Switchgear flash over, and injury to staff member. Presentation to AMEU Technical Meeting Sept 2009. By Roy Wienand 1 ARC FASH A bad day at the office for Electricians: ARC FLASH

More information

NEUTRAL SALT SPRAY TESTING REPORT TEST RESULTS. Kim Bray Materials Testing Officer AUTHORISED SIGNATORY. Bureau Veritas

NEUTRAL SALT SPRAY TESTING REPORT TEST RESULTS. Kim Bray Materials Testing Officer AUTHORISED SIGNATORY. Bureau Veritas 35-37 STIRLING STREET THEBARTON, SA 5031 P.O BOX 338, TORRENSVILLE PLAZA,SA. 5031 A.B.N. 86 000 928 816 Tel: (08) 8416 5260 Fax: (08) 8260 2760 NEUTRAL SALT SPRAY TESTING REPORT Client: Action Corrosion

More information

Standard Test Method for Colorfastness and Transfer of Color in the Washing of Leather 1

Standard Test Method for Colorfastness and Transfer of Color in the Washing of Leather 1 Designation: 00 Standard Test Method for Colorfastness and Transfer of Color in the Washing of Leather 1 This standard is issued under the fixed designation ; the number immediately following the designation

More information

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source TEST REPORT Kolay 5mm 20mil Wear Layer LVT with Fiberglass Core Project

More information

Why Thermostats Matter

Why Thermostats Matter Top Smart Thermostats for Preference and Usability Karen Herter, Ph.D. Why Thermostats Matter Thermostats manage ~25% of annual electricity use at SMUD Residential AC is responsible for >30% of SMUD peak

More information

Electrical Safety for Facility Managers and Building Owners

Electrical Safety for Facility Managers and Building Owners CEU s Copy of Slides Evaluation Form Follow up information Disclaimer. This seminar was produced to help explain the importance and need for electrical safety specifically for Facility Managers. It does

More information

Using Disposable Garments in Arc Flash Exposures

Using Disposable Garments in Arc Flash Exposures An e-hazard.com White Paper 13113 Eastpoint Park Blvd. Suite E Louisville, KY 40223 502-716-7073 http://www.e-hazard.com Using Disposable Garments in Arc Flash Exposures Hugh Hoagland, Sr. Managing Partner,

More information

Protection from Electric Shock and Arc Flash. Meeting OSHA Regulations and NFPA 70E Standards.

Protection from Electric Shock and Arc Flash. Meeting OSHA Regulations and NFPA 70E Standards. Be Smart. Be Safe. Protection from Electric Shock and Arc Flash. Meeting OSHA Regulations and NFPA 70E Standards. ISO 9001:2000 Registered SALISBURY 7520 N Long Ave Skokie Il 60077 Toll Free 877.406.4501

More information

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1

TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd Brigantine Drive Coquitlam, B.C. V3K 7C1 REPORT NUMBER: 101145164COQ-005 ORIGINAL ISSUE DATE: April 25, 2013 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, B.C. V3K 7C1 RENDERED TO udecor Inc.

More information

Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly

Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly ASTM E119-98: Standard Test Methods for Fire Tests of Building Construction and Materials* *Research-scale horizontal

More information

Flame retardant. Protectivewear fabrics by Klopman International

Flame retardant. Protectivewear fabrics by Klopman International Flame retardant Protectivewear fabrics by Klopman International Innovation in flame retardant protectivewear fabrics A wide range of and cotton rich fabrics with FR treatment Brand segments and performance

More information

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3

RENDERED TO Vipco Industries Inc th Avenue SE Calgary, AB T2C 0B3 REPORT NUMBER: 101207560COQ-001b ORIGINAL ISSUE DATE: June 12, 2013 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, B.C. V3K 7C1 RENDERED TO Vipco Industries

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 15538 First edition 2001-10-01 Protective clothing for firefighters Laboratory test methods and performance requirements for protective clothing with a reflective outer surface

More information

Honeywell Salisbury PrismShield Colors within Sight, Safety on Site

Honeywell Salisbury PrismShield Colors within Sight, Safety on Site Honeywell Salisbury PrismShield Colors within Sight, Safety on Site Definition and Risks of an Arc Flash Arc Flash is a dangerous condition associated with the release of massive amounts of energy produced

More information

ASTM D Horizontal Burning Rate Determination of "Marlon FS 1.5mm Clear" Polycarbonate Sheet

ASTM D Horizontal Burning Rate Determination of Marlon FS 1.5mm Clear Polycarbonate Sheet UNCONTROLLED ELECTRONIC COPY ASTM D 635-14 Horizontal Burning Rate Determination of "Marlon FS 1.5mm Clear" Polycarbonate Sheet A Report To: Brett Martin Ltd. 24 Roughfort Road Mallusk, Co. Antrim United

More information

DISCOVER 5 WAYS TO OPTIMIZE LAB EFFICIENCY Could your lab be more productive and consistent?

DISCOVER 5 WAYS TO OPTIMIZE LAB EFFICIENCY Could your lab be more productive and consistent? DISCOVER 5 WAYS TO OPTIMIZE LAB EFFICIENCY Could your lab be more productive and consistent? Our simple calculator helps you assess whether custom blends could boost your efficiency. 1 2 3 4 5 MORE TIME

More information

Model 5190-F Temperature/Humidity Probe

Model 5190-F Temperature/Humidity Probe Model 5190-F Temperature/Humidity Probe FAA APPROVED ECP234 2017 Mar 13 NOT FAA APPROVED User s Manual Rev. C All Weather Inc. 1165 National Drive Sacramento, CA 95834 USA 800.824.5873 www.allweatherinc.com

More information

WYLE LABORATORIES, INC. Huntsville Facility

WYLE LABORATORIES, INC. Huntsville Facility Page No. TOC 1 of 1 TABLE OF CONTENTS Page No. 1.0 INTRODUCTION... 1 1.1 Scope... 1 1.2 Product Description... 1 1.3 References... 1 1.4 Compliance Summary... 2 2.0 SYSTEM TEST CONFIGURATION... 2 2.1 Details

More information

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5 REPORT NUMBER: 3189147COQ-002 ORIGINAL ISSUE DATE: September 30, 2009 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, B.C. V3K 7C1 RENDERED TO Radial Engineering

More information

SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING

SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING Page 1 of 10 CONTENTS 1 SCOPE 2 DEFINITIONS 2.1 SURGE ARRESTER 2.2 GAPLESS METAL-OXIDE SURGE ARRESTERS 2.3

More information

FIBERSHIELD EW NEW PRODUCT LOW RADIANT HEAT TRANSFER ( PARTIAL PARTIAL INSULATION ) FIRE CURTAINS. Supported by full scale fire test data

FIBERSHIELD EW NEW PRODUCT LOW RADIANT HEAT TRANSFER ( PARTIAL PARTIAL INSULATION ) FIRE CURTAINS. Supported by full scale fire test data LOW RADIANT HEAT TRANSFER ( PARTIAL PARTIAL INSULATION ) GENERAL Fibershield EW is a NEW and INNOVATIVE low radiation attenuation and partially insulating automatic fire curtain. It was developed to meet

More information

CAN/ULC-S102 Surface Burning Characteristics of "8 mm Fire Rated High Pressure Laminate Phenolic Panel"

CAN/ULC-S102 Surface Burning Characteristics of 8 mm Fire Rated High Pressure Laminate Phenolic Panel ELECTRONIC DRAFT COPY CAN/ULC-S12 Surface Burning Characteristics of "8 mm Fire Rated High Pressure Laminate Phenolic Panel" A Report To: ABET Corporation 5 Paxman Road, Unit 1 Toronto, Ontario M9C 1B7

More information

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com Ad-hoc IEC 60331-2 x Ad-hoc investigation

More information

CAN/ULC-S102.2 Surface Burning Characteristics of "16 mm Multiwall Polycarbonate"

CAN/ULC-S102.2 Surface Burning Characteristics of 16 mm Multiwall Polycarbonate ELECTRONIC DRAFT COPY CAN/ULC-S12.2 Surface Burning Characteristics of "16 mm Multiwall Polycarbonate" A Report To: Polygal Plastics Industries, Ltd. Ramat Hashofet 19238 Israel Phone: 972-4-9596271 Email:

More information

NECA. Standard for Electrical Safety in the Workplace

NECA. Standard for Electrical Safety in the Workplace 4/23/2018 N E R C e- A di st N rib ot ut Fo io r n NECA Significant Changes to the 2018 NFPA 70E Standard for Electrical Safety in the Workplace NFPA 70E Standard for Electrical Safety in the Workplace

More information

Report VNLF Test Report

Report VNLF Test Report Report VNLF 081158.1 Test Report Applicant KLEEN-TEX Industries in Europa GmbH Münchner Straße 21 6330-Kufstein Austria Reference Mrs. Antje Schlegel Application Determination ofthe burning behaviour according

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 5658-2 Second edition 2006-09-15 Reaction to fire tests Spread of flame Part 2: Lateral spread on building and transport products in vertical configuration Essais de réaction

More information

ASTM E 662 Rate of Smoke Generation of OXIFREE TM198"

ASTM E 662 Rate of Smoke Generation of OXIFREE TM198 ELECTRONIC COPY ASTM E 662 Rate of Smoke Generation of OXIFREE TM198" A Report To: Oxifree Global LLC 22955 State Highway 249, Suite 6 Tomball, TX 77375 USA Phone: (281) 251-7171 E-mail: ed.hall@oxifree.com

More information

AN UNCOMPROMISING COMMITMENT TO SAFETY

AN UNCOMPROMISING COMMITMENT TO SAFETY AN UNCOMPROMISING COMMITMENT TO SAFETY Garments Manufactured by LONDON, CANADA 866.493.7839 westex.com 2845 W. 48th Place Chicago, IL 60632 USA TABLE OF CONTENTS The Westex Story... 4-7 Overview of Westex

More information

SIGMADEK, LTD. FIRE TEST REPORT

SIGMADEK, LTD. FIRE TEST REPORT SIGMADEK, LTD. FIRE TEST REPORT SCOPE OF WORK ASTM E84 TESTING ON ALUMINUM EXTRUSION DECK BOARD C/W PORCELAIN TILE INSERT REPORT NUMBER H5331.01-121-24 TEST DATE 09/13/17 ISSUE DATE 10/03/17 RECORD RETENTION

More information

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy

RENDERED TO. Laminam S.P.A. Via Ghiarola Nuova Fiorano Modenese Italy REPORT NUMBER: 100900037COQ-002 ORIGINAL ISSUE DATE: October 10, 2012 TEST REPORT EVALUATION CENTER Intertek Testing Services NA Ltd. 1500 Brigantine Drive Coquitlam, BC V3K 7C1 RENDERED TO Laminam S.P.A.

More information

Document Number: ELECTRICAL SAFETY ZSD-HMSAFESA Issue Date: July 4, 2017 Revision #: 3 Next Review Date: July 4, 2022

Document Number: ELECTRICAL SAFETY ZSD-HMSAFESA Issue Date: July 4, 2017 Revision #: 3 Next Review Date: July 4, 2022 STANDARD SARNIA REFINERY Document Number: 4000-ZSD-HMSAFESA-007047 Issue Date: July 4, 2017 Revision #: 3 Next Review Date: July 4, 2022 Document Owner: Manager, EH&S Document Contact: Safety Advisor SCOPE

More information

Model 5190-E Temperature/Humidity Probe

Model 5190-E Temperature/Humidity Probe Model 5190-E Temperature/Humidity Probe User s Manual Rev. D All Weather Inc. 1165 National Drive Sacramento, CA 95834 USA 800.824.5873 www.allweatherinc.com Copyright 2010, All Weather, Inc. All Rights

More information

ISO INTERNATIONAL STANDARD. Graphical symbols Safety colours and safety signs Part 2: Design principles for product safety labels

ISO INTERNATIONAL STANDARD. Graphical symbols Safety colours and safety signs Part 2: Design principles for product safety labels INTERNATIONAL STANDARD ISO 3864-2 First edition 2004-10-15 Graphical symbols Safety colours and safety signs Part 2: Design principles for product safety labels Symboles graphiques Couleurs de sécurité

More information

Why Buy Certified? Understanding Standards NFPA 2112 and ASTM F1506 and Why Certification Matters When Selecting FR PPE

Why Buy Certified? Understanding Standards NFPA 2112 and ASTM F1506 and Why Certification Matters When Selecting FR PPE Why Buy Certified? Understanding Standards NFPA 2112 and ASTM F1506 and Why Certification Matters When Selecting FR PPE May 3, 2018 Occupational Health & Safety, DuPont Protection Solutions Overview Workplace

More information

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in INFRASTRUCTURE TECHNOLOGIES Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in accordance with AS/NZS 3837:1998 Fire Testing Report Author: Heherson Alarde Report Number:

More information

CERTIFICATION SAFETY & BEYOND

CERTIFICATION SAFETY & BEYOND CERTIFICATION SAFETY & BEYOND Ferhun Emeksiz & R.M ( Max) Bradbury Client Manager & Fire Products Program Manager Global-Mark Pty Ltd Content Product Certification Understanding the framework Fundamental

More information

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE: Page 1 of 10 TEST REPORT REPORT NUMBER: 102317918SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE: EVALUATION CENTER Intertek Testing Services NA Inc. 16015 Shady Falls Road Elmendorf, TX 78112

More information

Southern California Gas Company Customer Programs Department

Southern California Gas Company Customer Programs Department Appliance Test Report SCGAT140220A Revision 0 Issued Date: March 2014 Duke 613Q-G1V Gas Convection Oven Performance Test Per ASTM F1496-13 Southern California Gas Company Customer Programs Department Food

More information

Test Report. Appliance EMF Testing

Test Report. Appliance EMF Testing Project: 11014506A Date: November 6, 2015 Model: 120V_WWF13NW Test Report On Appliance EMF Testing Copyright 2005 UL LLC UL LLC authorizes the above-named company to reproduce this Report provided it is

More information

ISO 7491 INTERNATIONAL STANDARD. Dental materials Determination of colour stability. Produits dentaires Détermination de la stabilité de couleur

ISO 7491 INTERNATIONAL STANDARD. Dental materials Determination of colour stability. Produits dentaires Détermination de la stabilité de couleur INTERNATIONAL STANDARD ISO 7491 Second edition 2000-09-01 Dental materials Determination of colour stability Produits dentaires Détermination de la stabilité de couleur Reference number ISO 2000 PDF disclaimer

More information

Contact person Date Reference Page Richard Johansson P (2) Fire Research

Contact person Date Reference Page Richard Johansson P (2) Fire Research issued by an Accredited Testing Laboratory Contact person Richard Johansson 215-8-13 5P4413 1 (2) Fire Research +46 1 516 56 75 richard.johansson@sp.se 12 ISO/IEC 1725 Sklejka-Pisz Paged S.A Ul. kwiatowa

More information

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source INTERNATIONAL STANDARD ISO 9239-1 Third edition 2010-06-15 Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source Essais de réaction au feu des

More information

IEC Method of test defined in IEC / -21 for determining the circuit integrity of electric cables under fire conditions

IEC Method of test defined in IEC / -21 for determining the circuit integrity of electric cables under fire conditions Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com IEC 60331-11-21 Method of test defined in

More information

FUNDERMAX GMBH FIRE TEST REPORT

FUNDERMAX GMBH FIRE TEST REPORT FUNDERMAX GMBH FIRE TEST REPORT SCOPE OF WORK ASTM E84 TESTING ON 19 MM MAX COMPACT REPORT NUMBER I0002.02-121-24 TEST DATE 01/29/18 ISSUE DATE 02/16/18 RECORD RETENTION END DATE 01/29/22 PAGES 10 DOCUMENT

More information

ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process

ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process 2010 IMO FTP Code Revisions Parts 2, 5, 7, 8, 9 & 10 Presented by: Juan Manuel Flores, P.E. Date:

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 871 Third edition 2006-11-15 Plastics Determination of ignition temperature using a hot-air furnace Plastiques Détermination de la température d'allumage au moyen d'un four à

More information

Vibration tests on a TNAML Luminaire

Vibration tests on a TNAML Luminaire Sebert Trillingstechniek B.V. Report M13.001-P13.001 rev.01 Date 26 august 2013 Vibration tests on a TNAML Luminaire Client Technor Benelux B.V. Veersteeg 15 4212 LR Spijk The Netherlands Contact Person

More information

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY White Paper BACKGROUND: Safety is paramount in the home appliance industry. Due to the possibility of human mis-application, over-current, or short circuit

More information

Arc Fault Detection Devices (AFDDs) Protecting People and Property

Arc Fault Detection Devices (AFDDs) Protecting People and Property Arc Fault Detection Devices (AFDDs) Protecting People and Property Singapore Standard : CP5 Code of practice for electrical installations - Foreword 2 BS 7671 : the 18 th Edition report Short Brief 3 BS

More information

PQS Independent type-testing protocol

PQS Independent type-testing protocol PQS Independent type-testing protocol WHO/XXX Original: English Distribution: General TITLE: Wall-mounted pen recording thermometer Product verification protocol: E06/TR04VP Applies to specification ref(s):

More information

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT FABRITRAK SYSTEMS, INC. FIRE TEST REPORT SCOPE OF WORK ASTM E84 TESTING ON POLYESTER INFILL REPORT NUMBER H5200.01-121-24 TEST DATE 08/31/17 ISSUE DATE 09/20/17 RECORD RETENTION END DATE 08/31/21 PAGES

More information

Product Guide North & South America

Product Guide North & South America Product Guide North & South America Home wash. Fabrics & transfer films. Non-flame resistant. Fabrics 8906 8910 8912 8925 Backing fabric/adhesive 100% Polyester 65% Poly/35% Cotton Fabric 65% Poly/35%

More information

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector PRODUCT SPECIFICATION 108-115057 29OCT13 Rev. A1 0.5mm Fine Stacking Hermaphroditic Type BTB Connector 1. SCOPE 1.1. Content This specification covers performance, tests and quality requirements for 0.5mm

More information

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC

Ad-hoc IEC Ad-hoc investigation to determine the fire performance of a cable junction box, using the principles of IEC Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com Ad-hoc IEC 60331-2 x Ad-hoc investigation

More information

ASTM E 662 Rate of Smoke Generation of "Moniflex as manufactured by Isoflex AB"

ASTM E 662 Rate of Smoke Generation of Moniflex as manufactured by Isoflex AB UNCONTROLLED ELECTRONIC COPY ASTM E 662 Rate of Smoke Generation of "Moniflex as manufactured by Isoflex AB" A Report To: Ciucevich 7200 Vermilion Ct. Wake Forest, NC 27587 USA Phone: (919) 570-291 E-mail:

More information

ISO INTERNATIONAL STANDARD. Textiles Method for assessing appearance of apparel and other textile end products after domestic washing and drying

ISO INTERNATIONAL STANDARD. Textiles Method for assessing appearance of apparel and other textile end products after domestic washing and drying INTERNATIONAL STANDARD ISO 15487 First edition 1999-12-15 Textiles Method for assessing appearance of apparel and other textile end products after domestic washing and drying Textiles Méthode d'évaluation

More information

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c 1.0 INTRODUCTION This report presents the results of a fire performance evaluation in accordance with the 2011 Edition of National Fire Protection Association (NFPA) Standard 265, Standard Methods of Fire

More information

ISO Plastics Film and sheeting Determination of water vapour transmission rate Infrared detection sensor method

ISO Plastics Film and sheeting Determination of water vapour transmission rate Infrared detection sensor method INTERNATIONAL STANDARD ISO 15106-2 First edition 2003-01-15 Plastics Film and sheeting Determination of water vapour transmission rate Part 2: Infrared detection sensor method Plastiques Film et feuille

More information

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009 P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com CLASSIFICATION CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE

More information

User s Guide FST1000 SERIES. Air Flow Switch with Two SPST Relay Contact Closures. Shop online at omega.com

User s Guide FST1000 SERIES. Air Flow Switch with Two SPST Relay Contact Closures. Shop online at omega.com User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info FST1000 SERIES ir Flow Switch with Two SPST Relay Contact Closures omega.com info@omega.com

More information

ISO INTERNATIONAL STANDARD. Protective gloves for firefighters Laboratory test methods and performance requirements

ISO INTERNATIONAL STANDARD. Protective gloves for firefighters Laboratory test methods and performance requirements INTERNATIONAL STANDARD ISO 15383 First edition 2001-09-01 Corrected version 2003-04-15 Protective gloves for firefighters Laboratory test methods and performance requirements Gants de protection pour sapeurs-pompiers

More information

TABLE OF CONTENTS. 1.0 INTRODUCTION Scope References Test Specimen Description Summary 1

TABLE OF CONTENTS. 1.0 INTRODUCTION Scope References Test Specimen Description Summary 1 Page No. TOC-i TABLE OF CONTENTS Page No. 1.0 INTRODUCTION 1 1.1 Scope 1 1.2 References 1 1.3 Test Specimen Description 1 1.4 Summary 1 2.0 TEST PROCEDURES AND RESULTS 2 2.1 High Temperature Test 2 2.2

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 15106-4 First edition 2008-06-01 Plastics Film and sheeting Determination of water vapour transmission rate Part 4: Gas-chromatographic detection sensor method Plastiques Film

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 25762 First edition 2009-07-01 Plastics Guidance on the assessment of the fire characteristics and fire performance of fibre-reinforced polymer composites Plastiques Lignes directrices

More information

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009 CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Sponsor Prepared by P.O. Box 70 NL-5750 AB DEURNE Efectis Nederland BV Lange Kleiweg 5 P.O. Box 1090 NL-2280 CB

More information

DNVGL-CP-0399 Edition March 2016

DNVGL-CP-0399 Edition March 2016 CLASS PROGRAMME Type approval DNVGL-CP-0399 Edition March 2016 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD

More information

Draft ES V1.1.1 ( )

Draft ES V1.1.1 ( ) Standard Transmission and Multiplexing (TM); Passive optical components; Fibre optic mechanical splices for single-mode optical fibre communications systems; Common requirements and conformance testing

More information

Report of Surface Burning Characteristics Tests on Samples As Submitted By Eco-Sol Ltd

Report of Surface Burning Characteristics Tests on Samples As Submitted By Eco-Sol Ltd October 05, 2011 Eco-Sol Ltd Mr. Paul Allcock Cardiff House Cardiff Rd Barry, Vale of Glamorgan, CF63 2AW Great Britain Our Reference: Subject: R27181/11CA40094 Report of Surface Burning Characteristics

More information

Reaction to fire classification report No C

Reaction to fire classification report No C Reaction to fire classification report. 17911C Owner of the classification report Tapetex B.V. Distributor: Vescom bv Churchilllaan 10 Sint Jozefstraat 20 5705 BK Helmond 5750 AB Deurne The Netherlands

More information

Electrical Safety Compliance: NFPA 70E

Electrical Safety Compliance: NFPA 70E Electrical Safety Compliance: NFPA 70E From Graybar and Schneider Electric Risks associated with shock and electrocution from inadvertent contact with energized parts have long been recognized as a threat

More information

CAN/ULC-S102 Surface Burning Characteristics of "ezobord 9 mm (Green)"

CAN/ULC-S102 Surface Burning Characteristics of ezobord 9 mm (Green) UNCONTROLLED ELECTRONIC COPY CAN/ULC-S12 Surface Burning Characteristics of "ezobord 9 mm (Green)" A Report To: ivekter Inc. 1625 Drew Rd. Mississauga, Ontario L5S 1J5 Phone: 416-665-3571 Attention: E-mail:

More information

FIRE RETARDANT ARCHITECTURAL WOOD COATING FIRE SHIELD FS020 FIRE-SHIELD SEALER. FS021 FIRE-SHIELD TOP COAT Available in different gloss

FIRE RETARDANT ARCHITECTURAL WOOD COATING FIRE SHIELD FS020 FIRE-SHIELD SEALER. FS021 FIRE-SHIELD TOP COAT Available in different gloss FIRE RETARDANT ARCHITECTURAL WOOD COATING ASTM E84 CLASS A FIRE SHIELD FS020 FIRE-SHIELD SEALER FS021 FIRE-SHIELD TOP COAT Available in different gloss www.duro-lak.com Easy to apply Water base sealer

More information

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome PERFORMANCE TEST REPORT Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome Report No: D3964.01-106-31 Report Date: 06/19/14 Test Record Retention Date: 06/03/18 130 Derry Court York, PA

More information

CAN/ULC-S109 Flame Resistance of "Argo" Fabric

CAN/ULC-S109 Flame Resistance of Argo Fabric CAN/ULC-S109 Flame Resistance of "Argo" Fabric A Report To: Design/Craft Fabric Corporation 2230 Ridge Drive Glenview, IL 60025 USA Phone: Email: (847) 904-7000 x128 mboynton@design-craft.com Submitted

More information

Janine Bain Rhonda Lewis Harland Hirst Sandra Olive David Johnson Edward Maurer Kathy Felsten Joe Halle

Janine Bain Rhonda Lewis Harland Hirst Sandra Olive David Johnson Edward Maurer Kathy Felsten Joe Halle WEST CENTRAL FLORIDA SAFETY ALLIANCE MEETING NOTES July 20, 2012, 10:00 AM Noon Our thanks to Lanier Upshaw of Lakeland for hosting us at their facility and to Saddle Creek Corporation for sponsoring the

More information

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1 Exova Warringtonfire Holmesfield Road Warrington WA1 2DS United Kingdom T : +44 (0 1925 655116 F : +44 (0) 1925 655419 E : warrington@exova.com W: www.exova.com BS EN 13823: 2010 Reaction to Fire Tests

More information

UL 94 Flammability Ratings: Introduction

UL 94 Flammability Ratings: Introduction UL 94 Flammability Ratings: Introduction UL intends this standard to serve as a preliminary indication of a plastics acceptability for use as part of a device or appliance with respect to its flammability.

More information

ISO INTERNATIONAL STANDARD. Earth-moving machinery Hazard detection systems and visual aids Performance requirements and tests

ISO INTERNATIONAL STANDARD. Earth-moving machinery Hazard detection systems and visual aids Performance requirements and tests INTERNATIONAL STANDARD ISO 16001 First edition 2008-02-15 Earth-moving machinery Hazard detection systems and visual aids Performance requirements and tests Engins de terrassement Dispositifs de détection

More information

Procedure for the Approval of New Fire Detection and Alarm Technologies

Procedure for the Approval of New Fire Detection and Alarm Technologies VdS Guidelines for Automatic Fire Detection and Fire Alarm Systems VdS 3469en Procedure for the Approval of New Fire Detection and Alarm Technologies VdS 3469en : 2016-01 (01) Publisher and publishing

More information

GUARDIAN FIRE TESTING LABORATORIES, INC.

GUARDIAN FIRE TESTING LABORATORIES, INC. GUARDIAN FIRE TESTING LABORATORIES INC. Testing & Listing Field Labeling Page 1 of 5 Engineering & Product Certification Services Factory Inspections Guardian Fire Testing Laboratories, Inc. Phone: 716

More information

Flame Resistant Clothing: Statistics, Standards and Safety

Flame Resistant Clothing: Statistics, Standards and Safety Session No. 570 Flame Resistant Clothing: Statistics, Standards and Safety Introduction Rob Whittenberger President Tyndale Company, Inc. Pipersville, Pennsylvania For over twelve years, the author has

More information

ETSI TS V1.2.1 ( )

ETSI TS V1.2.1 ( ) TS 101 263 V1.2.1 (2004-07) Technical Specification Transmission and Multiplexing (TM); Passive optical components; Fibre optic mechanical splices for single-mode optical fibre communications systems for

More information

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009 P.O. Box 554 2665 ZN Bleiswijk Brandpuntlaan Zuid 16 2665 NZ Bleiswijk The Netherlands +31 88 3473 723 nederland@efectis.com OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN 13501-1:2007+A1:2009 Classification

More information

DUAL MIRROR ALUMINIZED FABRICS. Protection You Can Count On. Value You Can t Beat.

DUAL MIRROR ALUMINIZED FABRICS. Protection You Can Count On. Value You Can t Beat. S Over 0 Years of Innovation Leveraging its roots as a silk manufacturer in the early 1900 s, Gentex pioneered the technology of combining metals with fabrics in the 190 s for U.S. military researchers

More information

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA0 Series, (IEC)

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA0 Series, (IEC) Energy Division Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA0 Series, (IEC) Bowthorpe EMP distribution metal oxide surge arrester DA0 series Tyco Electronics Bowthorpe EMP business

More information

ETSI TS V1.2.1 ( )

ETSI TS V1.2.1 ( ) TS 100 783 V1.2.1 (2004-08) Technical Specification Transmission and Multiplexing (TM); Passive optical components; Fibre optic fusion splices for single-mode optical fibre transmission systems for indoor

More information

AN UNCOMPROMISING COMMITMENT TO SAFETY

AN UNCOMPROMISING COMMITMENT TO SAFETY AN UNCOMPROMISING COMMITMENT TO SAFETY TABLE OF CONTENTS The Westex Story... 4-7 Overview of Westex Flame Resistant Fabrics... 8-11 Westex Engineering Technology... 12-13 Flame Resistant Clothing Basics

More information

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services INFRASTRUCTURE TECHNOLOGIES Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services Test Report Author: Peter Gordon Report number: FSP 1960 Date: 5 February 2019 Client:

More information

Form: KSD-100:10 Page 1 of 3

Form: KSD-100:10 Page 1 of 3 /Translation from the Lithuanian language/ Form: KSD-100:10 Page 1 of 3 /Logo: GTC; DBS/ REACTION TO FIRE TESTING DIVISION FIRE REASEARCH CENTRE FIRE AND RESCUE DEPARTMENT UNDER THE MINISTRY OF THE INTERIOR

More information

Test Report to AS/NZS :2015. Report No. T160402_S

Test Report to AS/NZS :2015. Report No. T160402_S Page 1 of 6 EMC Technologies Pty Ltd ABN 82 057 105 549 Unit 3/87 Station Road Seven Hills NSW 2147 Australia Telephone +61 2 9624 2777 Facsimile +61 2 9838 4050 Email sales@emctech.com.au Test Report

More information

Report Of Surface Burning Characteristics Tests On Coated Louvered Door Panels As Submitted By Contego International Inc.

Report Of Surface Burning Characteristics Tests On Coated Louvered Door Panels As Submitted By Contego International Inc. August 11, 2017 Contego International Inc. Mr. Danny French PO Box 49 Rochester, IN 46975-0049 Our Reference: R25382 / 4788022828 Subject: Report Of Surface Burning Characteristics Tests On Coated Louvered

More information