1 ExiCheck Gas Exchange Accessory Operator s Manual Manual Part Number Rev 0

2 COPYRIGHT 2015 Teledyne CETAC Technologies Rev 0, June, 2015 Teledyne CETAC Technologies authorizes its customers to reproduce, transmit, or store this document in its entirety, including this page, for the express purpose of installing, operating, or maintaining the product described herein. Teledyne CETAC Technologies Customer Service & Support Industrial Road Omaha, Nebraska 68144, USA Phone (800) (USA only) Phone +1 (402) Fax +1 (402) REVISIONS Teledyne CETAC Technologies strives to provide the scientific community with an unparalleled combination of effective technology and continuing value. Modular upgrades for existing instruments will continue to be a prime consideration as designs progress. Teledyne CETAC Technologies reserves the right to revise this document and/or improve products described herein at any time without notice or obligation. TRADEMARK ACKNOWLEDGEMENTS Teledyne Photon Machines is a brand of Teledyne CETAC Technologies. ATL and ATLEX are trademarks of ATL Lasertechnik GmbH. Windows is a registered trademark of Microsoft Corporation in the United States and other countries. PharMed and Tygon are registered trademarks of Saint-Gobain Performance Plastics. DuPont and Teflon are trademarks or registered trademarks of E.I. du Pont de Nemours and Company. Swagelok is a registered trademark of Swagelok Company. KIMWIPES is a registered trademark and KIMTECH SCIENCE is a trademark of Kimberly-Clark Worldwide, Inc All other marks are the property of their respective owners.

3 Contents 1 Introduction...5 Overview... 5 ExiCheck Components... 7 System Integration Panel: Mounts the control unit so that it can be conveniently accessed from the outside of the laser ablation system.. 7 Who Should Use This Product Operator Qualifications... 9 Where to Go for More Information...10 Installation...10 Ventilation Using the ExiCheck Accessory Using the Laser Ablation System...11 Front Panel Indicators...11 Starting the ExiCheck Accessory...11 Setting the Clock...12 Exchanging the Laser Gas for the First Time...12 Exchanging the Laser Gas Manually...13 Exchanging the Laser Gas On a Defined Schedule...13 Calculation of Exchange Intervals...13 Starting the Laser Ablation System...14 Shutting Down the Laser Ablation System...14 Shutting Down the ExiCheck Accessory...14 Safing the Laser Ablation System...14 Changing the Gas Cylinders Maintaining the ExiCheck Accessory Checking the Gas Pressure...17 Updating the Firmware...17 Changing the Battery Troubleshooting the ExiCheck Accessory Power System Problems...19 Fuses...20 Returning the Product for Service...20 Shipping the Product Safety and Regulatory Information Characteristics...21 Environmental Characteristics...21 Power Requirements: Control Unit...22 Input and Output Connectors: Control Unit...22 Input and Output Connectors: Sensor Module...22 Fuses

4 Contents Safety Notices...23 Ventilation Power Cord Requirements and Safety Maintenance Mains Disconnect Cleaning Instructions Operating Environment Explanation of Caution and Warning Notices Electromagnetic Interference...25 Explanation of Regulatory Marks

5 1 Introduction Overview The ExiCheck accessory connects to your Analyte Excite or Analyte G2 excimer gas system and provides a way to automatically exchange the ArF gas, even when the laser ablation system is turned off. The ATL excimer laser heads used by Teledyne Photon Machines use a gas mixture of argon and fluorine. The fluorine component is reactive and degrades over time and requires replacement in the laser head after either two weeks or when the energy output degrades. Stale gas causes a lot of down time as the system has to be re-passivated by saturating the internal surfaces with fluorine. Stale gas also causes lower laser energy output, greater pulse-topulse variability, and eventually decreased crater quality. Using the ExiCheck accessory maintains optimal laser performance without wasting gas or consuming operator time. Automatic gas exchange is especially useful when the laser is not being used for long periods of time, to maintain passivation in the laser cavity and internal tubing lines. The gas exchange is performed in full compliance with the procedure specified by ATL, including verification of adequate gas pressure and internal verification that the flow of gas is shut off during the evacuation part of the procedure. This version of the system supports two modes: Manual Gas Exchange Gas exchange is initiated from the front panel of the control unit Scheduled Gas Exchange Gas is exchanged at a regular interval, programmed from the front panel of the control unit Power and control signals to the laser pass through the ExiCheck control unit so that the ExiCheck can control the laser to perform gas exchanges while remaining transparent to any computer program which is controlling the laser. 5

6 Chapter 1: Introduction Laser Ablation System Main Power Switch Laser Ablation System Key Switch Laser Ablation System Electronics ATL Laser Figure 1 Power Flow Before ExiCheck is Installed Laser Ablation System Main Power Switch Laser Ablation System Key Switch Laser Ablation System Electronics ATL Laser ExiCheck Control Unit Power Switch ExiCheck Control Unit Key Switch ExiCheck Control Unit Figure 2 Power Flow With ExiCheck 6

7 Chapter 1: Introduction ExiCheck Components The ExiCheck accessory includes the following major components: Control Unit: Controls the timing of gas exchanges. Data and power pass through this unit to the laser. Sensor Module: Provides an interface to the sensors and valves. Pressure Sensor: Installed in the premix regulator. Gas Control Valve: Installed in the premix regulator for the ArF supply. This valve is normally closed; the ExiCheck system opens the valve so that gas can flow to the laser. System Integration Panel: Mounts the control unit so that it can be conveniently accessed from the outside of the laser ablation system. Display Power Light Keypad System On/Off Switch Figure 3 Control Unit Front View Control Unit Power Switch Fuses Platform Power Input Serial Connection to Laser Serial Connection from Computer Power Input Connector Power Output Connector ExiCheck Connect (Sensor Module Connector) Ethernet Port (not used) Figure 4 Control Unit Back View Service Port USB Port (for Firmware Upgrade) 7

8 Chapter 1: Introduction Figure 5 Sensor Module Front View Control Unit Connector Aux Control Connector (not used) Aux Power Input (not used) Purge Gas Valve Connector (not used) Premix Gas Valve Connector Pressure Sensor Connector Figure 6 Sensor Module Back View Figure 7 Control Unit with System Integration Panel Analyte G2 8

9 Chapter 1: Introduction Figure 8 Control Unit with System Integration Panel Analyte Excite Who Should Use This Product Operator Qualifications This product is intended for use by analytical chemists and lab technicians. To use this product safely and effectively, at least a beginning level of knowledge and experience about excimer laser safety, electrical/ electronic equipment operation and maintenance, personal computers and ICP-MS or ICP-OES are required. Laser safety certification for operators is not required, but all users should familiarize themselves with laser safety before using the laser ablation system. WARNING INHALATION HAZARD The ExiCheck gas exchange accessory controls pressurized gas containing fluorine, which is toxic and corrosive and may cause serious injury if inhaled. Provide adequate ventilation at all times. Manually shut off gas flow at the cylinder when installing the accessory and whenever there is a chance of gas release. Learn and follow your laboratory s safety policy for pressurized, caustic gases. If a gas release is suspected, do not enter the room without protective equipment including self-contained breathing apparatus. WARNING CHEMICAL INJURY HAZARD This product is intended for use only by qualified operators who have been trained in safe laboratory practices and compressed gas handling. Make sure you know the hazards associated with all of the gases and other chemicals you are using, and take the appropriate precautions. Exposure to laboratory chemicals may result in serious injury. ELECTRICAL HAZARDS This product has electrical components which could pose a shock or fire hazard. Read all warnings notices before using the product. 9

10 Chapter 1: Introduction Where to Go for More Information The ExiCheck Installation Guide (part number for the Analyte G2 and for the Analyte Excite) contains information on how to install the ExiCheck accessory. Teledyne Photon Machines is a brand of Teledyne CETAC Technologies. If you need further assistance, contact us at: Teledyne CETAC Technologies Customer Service and Support Phone: 1 (800) (USA only) +1 (402) Fax: +1 (402) CETACservice@teledyne.com Installation No site preparation is needed other than what is required for the laser ablation system. Installation requires access to high-voltage wiring and the ArF premix gas supply. Therefore, it is strongly recommended that installation be performed by a trained Teledyne CETAC Technologies representative. If you need to install the system yourself, refer to the Installation Guide. Ventilation If you are not using the system integration panel, allow at least 5 cm clearance on all sides of the control unit for ventilation. CAUTION Do not operate the instrument if the cooling fan is blocked or obstructed in any manner. 10

11 2 Using the ExiCheck Accessory Using the Laser Ablation System Front Panel Indicators POWER LED: The LED located on the front of the control unit informs the operator of the current instrument conditions as follows: Off: Power is turned off. Green: Power is turned on. Starting the ExiCheck Accessory 1 Power on the laser ablation system. 2 Turn the power switch on the back of the ExiCheck control unit ON (1). 3 Insert the key and turn the key switch on the front of the ExiCheck control unit ON (1). Upon turning on the key switch, the display will show the following for about 45 seconds while the system starts up: ExiCheck Starting Please wait Once started, the display will show the Home screen that shows the time/date of the last gas exchange and the button to go to the main menu: 11

12 Chapter 2: Using the ExiCheck Accessory Last Laser Fill: YYYY-MM-DD hh:mm:ss [Main Menu] The main menu alternates between displaying the date of the last laser fill and the date of the next scheduled fill. 4 Verify that the valve on the premix cylinder is fully open. Gas flow will be controlled by the ExiCheck accessory without operator intervention. When starting the ExiCheck accessory for the first time, set the secondary regulator to 7 bar to ensure that adequate pressure is available to complete a gas exchange. Setting the Clock 1 Using the buttons on the control unit, select Main Menu. 2 Select Setup. 3 Select Set Date & Time. 4 Set the current date. 5 Press the Select key (the white button). 6 Scroll down and set the current time in 24-hour format. 7 Press the Select key. 8 Select Save. Exchanging the Laser Gas for the First Time 1 Using the buttons on the control unit, select Main Menu. 2 Select Gas Exchange. 3 Select Start. 4 When the gas exchange has begun, adjust the secondary pressure regulator s pressure reading to be approximately 7 bar, but no more than 7.2 bar. If the pressure is too low, turn the valve about a quarter turn at a time and re-check the pressure. 12

13 Chapter 2: Using the ExiCheck Accessory Exchanging the Laser Gas Manually 1 Shut down the Chromium software. 2 Using the buttons on the control unit, select Main Menu. 3 Select Gas Exchange. 4 Select Start. Gas exchange takes approximately 3 minutes, 30 seconds when the tank is at full pressure. Select Cancel to stop the gas exchange once it has begun. Exchanging the Laser Gas On a Defined Schedule 1 Using the buttons on the control unit, select Main Menu. 2 Select Setup. 3 Select Exchange Interval. 4 Set the number of days between gas exchanges and the time of day when the exchange should be performed. Press the Select key (the white button) to complete each entry. The exchange interval can be any number of days between 1 and 14. By default, the ExiCheck will conduct gas exchanges every 14 days at 23:00. 5 Scroll down and select Save. Calculation of Exchange Intervals The date and time of the ExiCheck s next scheduled gas exchange is calculated by: 1) Adding the number of days specified in the Conduct exchange every days setting to the date of the last completed exchange. 2) After that day is reached, waiting until the specified At time: : :00 time. 3) If the user cancels the scheduled exchange before it completes, the ExiCheck will wait until the next day at the At time: : :00 time to conduct a gas exchange. 4) If the laser is in use at the scheduled exchange time, the ExiCheck will wait until the next day at the At time: : :00 time to conduct a gas exchange. NOTE Manually exchanging the gas will reset the days counter. Therefore, if you had it set to do a gas exchange every 7 days at 1500 (3:00pm), and you did a 13

14 Chapter 2: Using the ExiCheck Accessory manual gas exchange on Wednesday at 1430, the next gas exchange the ExiCheck would perform would be on the following Wednesday at If an exchange is overdue (because you reduced the exchange interval, or because the exchange was cancelled or the laser was in use), an exchange will be performed when the clock reaches the specified time of day, then exchanges will be performed at the specified interval. Starting the Laser Ablation System 1 If the ExiCheck accessory is not already turned on, turn it on. 2 Wait for the ExiCheck accessory to display the home screen (showing the date of the last laser fill and the date of the next scheduled fill). 3 Start the laser ablation system as normal (turn on the laser key switch, if needed, and start Chromium or the ATL software). Shutting Down the Laser Ablation System The shutdown procedure for the laser ablation system is not changed by the presence of the ExiCheck accessory. Do not turn the ExiCheck accessory off or turn off the main power switch to the laser ablation system unless it is really necessary. Shutting Down the ExiCheck Accessory NOTE The ExiCheck accessory is designed to be left on, even when the laser is not in use. It is only necessary to shut down the ExiCheck accessory for maintenance activities such as disconnecting a gas line. 1 Insert the key and turn the key switch on the front of the control unit OFF (0). Safing the Laser Ablation System To place the laser ablation system in a safe state for maintenance: 1 Shut off power to the laser ablation system by turning the key switch OFF (0). 2 Insert the key and turn the key switch on the front of the ExiCheck control unit OFF (0). This turns off the ExiCheck accessory and ensures that solenoid valve on the output of the regulator stays closed. 14

15 Chapter 2: Using the ExiCheck Accessory 3 Shut off the ArF gas cylinder s main valve. Remember that your laboratory safety policy may also require lockout/tagout procedures when working with pressurized gases. Changing the Gas Cylinders 1 Leave the ExiCheck system ON. 2 Change the cylinders as prescribed in the ATL manual, using the ATL Laser Control Software. 3 During the next gas exchange, check that the pressure is approximately 7 bar. 15

16 Chapter 2: Using the ExiCheck Accessory This page is intentionally blank. 16

17 3 Maintaining the ExiCheck Accessory Routine maintenance of the laser ablation system consists of verifying the performance of each component. There are no components which require periodic replacement. Checking the Gas Pressure The main valve on the premix gas cylinder should normally remain open. Periodically check the secondary pressure regulator s pressure reading. This should be checked about once every three months and verified to be approximately 7 bar. This will ensure that the ExiCheck can always complete a gas exchange. If the pressure is low, adjust the secondary pressure by a maximum of a quarter turn and then verify that it does not read more than 7.2 bar during an entire gas exchange. Updating the Firmware 1 Obtain the newest firmware from Teledyne Photon Machines. The firmware update file will be named ExiCheck-Update.tgz regardless of the version number. 2 Copy the firmware update file to the root level (in other words, not inside any folder) of a USB storage device. 3 Turn off the ExiCheck accessory and plug the USB storage device into one of the two USB ports on the back of the ExiCheck control unit. 4 Turn on the ExiCheck and wait for it to boot up. This will take approximately one minute. 17

18 Chapter 3: Maintaining the ExiCheck Accessory 5 Once the ExiCheck is booted up, the ExiCheck will show the status of the firmware installation. 6 Once it is finished, the ExiCheck will ask you to remove the USB storage device. Once it is removed, the ExiCheck will restart and run the new firmware. 7 To check the results of the update, connect the USB storage device to a computer and examine the appropriate text file. When the update is complete, three new files will be saved onto the USB storage device. The first two files are ExiCheck Firmware Update.txt and ExiCheck Firmware Update Windows Format.txt. These files confirm that the update was successful or list any failures, errors, or warnings that were encountered. The two files contain the same information, but with different line formats for Mac/Linux/Unix and Windows. The other file is ExiCheck-Update Diagnostic Data.tgz. 8 Please the ExiCheck-Update Diagnostic Data.tgz file to cetacservice@teledyne.com. The information in this file will help Teledyne Photon Machines improve the ExiCheck and verify that the ExiCheck is working properly. Changing the Battery The ExiCheck control unit includes a battery which is used to maintain the clock when power is removed from the system. This lithium battery can maintain the clock for a minimum of 10 years when the ExiCheck system is powered off. This battery is not user replaceable. Contact Teledyne CETAC Technologies if you believe the battery needs to be replaced. 18

19 4 Troubleshooting the ExiCheck Accessory In the event that the product does not function properly, isolate the problem to determine if it originates in the power system, the data connections, the system configuration, or one of the components of the ExiCheck accessory. This chapter explains how to troubleshoot minor problems. If you cannot solve a problem using the steps given in this chapter, contact the manufacturer or an authorized service representative for assistance. Power System Problems If the laser ablation system is not responding, power may not be getting to the ExiCheck accessory or to the laser cabinet. If this is the case, the power indicator (green LED) on the front of the ExiCheck control unit will be off. To troubleshoot this problem, complete the following steps: WARNING DANGER - HIGH VOLTAGE. The laser ablation system contains lethal current and voltage levels. Do not attempt any service beyond described troubleshooting procedures. 1 Check the POWER LED on the control unit. If the LED is not lit, first make sure that both the power switch on the back of the control unit and the key switch on the front of the control unit are turned on. 2 Check that the AC line cord on to the control unit is connected to the 220 V AC outlet in the laser ablation system cabinet. 19

20 Chapter 4: Troubleshooting the ExiCheck Accessory 3 Check the laser ablation system itself is turned on. WARNING Do not attempt to service the electronics in the control unit or sensor module. There are no user serviceable parts inside the ExiCheck cabinet. The covers should not be opened except by an authorized service representative. Fuses Control Unit: The fuses are accessed from the rear of the control unit and are held in place by a cover which can be removed with a straight screwdriver. Check and replace if necessary. Contact Teledyne CETAC Technologies if there are any questions or if the unit requires factory service. Fuse Rating: 5mm x 20mm Glass-Tube Fuse, Fast Acting, 250 VAC, 6.3 Amp (quantity 2) Sensor Module: The 1.5 A soldered fuse is not customer serviceable. Return the sensor module to the factory for repair. WARNING Replace fuses with specified type(s) and rating(s) only. If the AC power is within specifications and the laser ablation system will not operate, call Teledyne CETAC Technologies or an authorized service representative. Returning the Product for Service Refer to the following information if you need to return the product to the factory for service. Note that support for Teledyne Photon Machines products is provided through Teledyne CETAC Technologies. Shipping the Product Follow these guidelines when shipping the product: Contact Teledyne CETAC Technologies before shipping the product. Pre-pay all shipping expenses including adequate insurance. Write the following information on a tag and attach it to the product: Name and address of the owner Product model number and serial number Description of service required or failure indications Mark the shipping container as FRAGILE. In all correspondence, refer to the instrument by model name or number and full serial number. Do not return products which are contaminated by radioactive materials, infectious agents, or other materials constituting health hazards to Teledyne CETAC Technologies employees. 20

21 5 Safety and Regulatory Information Review this product and related documentation to familiarize with safety markings and instructions before you operate the instrument. Characteristics Environmental Characteristics Operating Temperature +5 C to +40 C (+41 F to +104 F) Non-Operating Temperature +0 C to +55 C (+32 to +131 F) Operating Altitude Operating Relative Humidity Non-Operating Relative Humidity Up to 2,000 m (6,562 ft) 0% to 80% non-condensing for temperatures up to 31 C, decreasing linearly to 50% at 40 C 0% to 95% non-condensing Pollution Degree Pollution Degree 2 Normally no pollution or only dry, nonconductive pollution occurs. The pollution has no influence. Occasionally, however, a temporary conductivity caused by condensation may be expected. Table 5-1: Environmental Characteristics For indoor use only. Avoid sudden, extreme temperature changes which could cause condensation on circuit boards in the product. 21

22 Chapter 5: Safety and Regulatory Information Power Requirements: Control Unit AC OUT Input: AC Voltage, Current, and Frequency V AC ± 10% ~ 6.3 A Hz Installation Category: CAT II (Line voltage in appliance and to wall outlet) Output: 220 V AC, Hz, 6.3 A max Table 5-2: Power Requirements The entire laser ablation system must be connected to a circuit which is capable of supplying 10 amps (at 220 V AC). Input and Output Connectors: Control Unit EXICHECK CONNECT PLATFORM POWER INPUT TO LASER FROM COMPUTER ETHERNET USB SERVICE PORT Connect only to the EXICHECK CONNECT port on the sensor module V DC. Connect only to the laser ablation system power supply,as described in the Installation Guide DB-9 RS-232 serial connection to the ATL laser. (max ±12 VDC, 8 ma) DB-9 RS-232 serial connection to the controller PC. (max ±12 VDC, 8 ma) Not used Used only for firmware updates. (max 5 VDC, 0.75A) For use only by authorized Teledyne Photon Machines personnel Input and Output Connectors: Sensor Module EXICHECK CONNECT AUX. CONTROL AUX POWER PREMIX Connect only to the EXICHECK CONNECT port on the control unit (max 24 VDC, 1.5 A) Not used. Anticipated use is for a USB connection to an alternate controller, requiring use of AUX POWER input (max 5 VDC, 0.75 A) Not used. DC Voltage and Current 24 V 1.5 A Installation Category: CAT I (Mains isolated) Connect only to the solenoid valve in the premix pressure regulator, as described in the Installation Guide (max 24 VDC, 1.5 A) 22

23 PRESS. SENSOR Connect only to the pressure sensor in the premix pressure regulator, as described in the Installation Guide (max 24 VDC, 1.5 A) PURGE Not used (max 24 VDC, 1.5 A) Fuses See page 20 for fuse replacement instructions and fuse ratings. Safety Notices WARNING If the equipment is used in a manner not specified by Teledyne CETAC Technologies, the protection provided the equipment may be impaired. Repair or service that this not covered in this manual should only be performed by qualified personnel. Ventilation The control unit cooling fan should remain unobstructed at all times. Do not operate the instrument if the cooling fan is blocked or obstructed in any manner. Power Cord Requirements and Safety Maintenance The power cord set supplied with your instrument meets the requirements of the country where you purchased the instrument. If you need a different power cord, contact Teledyne CETAC Technologies. The operator should check the power/signal supply cord condition. The equipment should not be operated if the mains inlet is cracked or broken. Any obvious damage to the case (from a drop or fall) should be checked by service personnel for loose or damaged parts. See individual parts lists for approved replacement parts Mains Disconnect Power mains disconnect requires unplugging the laser ablation system power cord at the wall outlet. Ensure the power cords are easily accessible and removable, in the event of an emergency which requires immediate disconnection. WARNING SHOCK HAZARD Ensure that the power cords are disconnected before removing any covers. Cleaning Instructions For additional cleaning information, see cleaning in the index. To clean the exterior surfaces of the instrument, complete the following steps: 1 Shut down and unplug the instrument. 23

24 Chapter 5: Safety and Regulatory Information 2 Wipe the display on the front of the ExiCheck control unit using a towel or soft cloth dampened with clear water. 3 Wipe other surfaces of the instrument exterior surfaces only using a towel dampened with a lab-grade cleaning agent. 4 Repeat step 3, using a towel dampened with clear water. 5 Dry the instrument exterior using a dry towel. WARNING SHOCK HAZARD Do not allow any liquid to enter the instrument cabinet other than as intended through the specified tubing, or come into contact with any electrical components. The instrument must be thoroughly dry before you reconnect power or turn the instrument on. Operating Environment WARNING WARNING WARNING SHOCK HAZARD To reduce the risk of fire hazard and electrical shock, do not expose to rain or humidity. To reduce the risk of electrical shock, do not open the cabinet. Protection provided by the equipment may be impaired if the equipment is used in a manner not specified by the manufacturer. SHOCK HAZARD Equipment is not intended for wet locations. Miscellaneous liquids in the equipment could cause hazardous conditions. EXPLOSION HAZARD Do not operate in an explosive atmosphere. Explanation of Caution and Warning Notices Warning symbol marked on equipment. This symbol means Attention! Refer to the manual. WARNING The WARNING notice denotes a hazard. It calls attention to a procedure, practice, or the like, that, if not correctly performed or adhered to, could result in personal injury. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood CAUTION The CAUTION notice calls attention to a procedure or practice that if not correctly performed or adhered to, could result in equipment damage, loss of data, or inaccurate data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. 24

25 Electromagnetic Interference FEDERAL COMMUNICATIONS COMMISSION (FCC) NOTICE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a commercial installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential environment is likely to cause harmful interference, in which case the user will be required to correct the interference at his expense. MODIFICATIONS The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Teledyne CETAC Technologies may void the user's authority to operate the equipment. CABLES Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods to maintain compliance with FCC Rules and Regulations. CANADIAN NOTICE This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled "Digital Apparatus" ICES-003 of the Department of Communications. AVIS CANADIEN Cet appareil numerique respecte les limites de bruits radioelectriques applicables aux appareils numeriques de Classe A prescrites dans la norme sur le materiel brouilleur: "Appareils Numeriques," NMB-003 edictee par le ministre des Communications. Explanation of Regulatory Marks Do not dispose in domestic household waste. The affixed label indicates that you must not discard this electrical/electronic product in domestic household waste, in compliance with the European Waste Electrical and Electronic Equipment Directive (WEEE, 2002/96/EC). For instructions on how to return end-of-life equipment, producer-supplied electrical accessories, or auxiliary items for proper disposal please contact the supplier or importer. In the event a supplier cannot be reached, contact Teledyne CETAC Technologies customer service department at 1 (800) The CE mark is a registered trademark of the European Community. This CE mark shows that the product complies with all the relevant European Legal Directives. 25

26 Index avis Canadien, 25 battery, 18 characteristics electrical, 22 cleaning, 23 disposal, 25 electrical characteristics, 22 FCC notice, 25 fuses, 20 humidity, 21, 24 ICES 003, 25 interference, 25 interlocks status indicator, 11 LED. See light light, status, 11 mains disconnect, 23 operator qualifications, 9 pollution degree, 21 power requirements, 22 power cord, 23 power off procedure, 14 qualifications, operator, 9 regulatory notices, 21 return procedure, 20 safety information, 21 service, 20 shipping, 20 status light, 11 symbols, warning, 24 temperature operating, 21 ventilation requirements, 10 warning symbols, 24 WEEE notice, 25 Manual Part Number Rev 0 Printed in USA 26

safety & regulatory information

safety & regulatory information safety & regulatory information Document Part Number: 338610-001 Sixth Edition June 2006 This guide provides safety and regulatory information that is compliant with U.S., Canadian, and International regulations.

More information

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens.

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens. User Guide Luxxor 35 LED Light Source 207 Tremont Street, Rochester, New York 14608 800.536.0790 Fax: 585.235.6645 REV. 0116 gradientlens.com warnings & cautions Warnings & Cautions PORTABLE CAMERA Luxxor

More information

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide March 2006 (First Edition) Part Number 413611-001 Copyright 2006 Hewlett-Packard Development Company, L.P. The information

More information

3M Benchtop Air Ionizer 963E. User s Guide

3M Benchtop Air Ionizer 963E. User s Guide 3M Benchtop Air Ionizer 963E User s Guide 1 Table of Contents Section Page Safety Information...3 1. Description...4 2. Performance...4 3. Power Requirements...4 4. Installation...4 5. Operation...5 6.

More information

Model SWH-4000 Multi-Technology Mullion 125 KHz and MHz (Flex) Reader Installation Guide. Version A0 Part Number UM-104 September 2005

Model SWH-4000 Multi-Technology Mullion 125 KHz and MHz (Flex) Reader Installation Guide. Version A0 Part Number UM-104 September 2005 Model SWH-4000 Multi-Technology Mullion 125 KHz and 13.56 MHz (Flex) Reader Installation Guide Version A0 Part Number UM-104 September 2005 1 CONTENTS Introduction................................................

More information

Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide. Version A0 Part Number UM-102 September 2005

Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide. Version A0 Part Number UM-102 September 2005 Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide Version A0 Part Number UM-102 September 2005 1 CONTENTS Introduction................................................

More information

Network Camera. Quick Guide DC-T1233WHX. Powered by

Network Camera. Quick Guide DC-T1233WHX. Powered by Network Camera Quick Guide DC-T1233WHX Powered by Safety Precautions WARNING RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE

More information

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide P/N 1072921 REV A ISS 10FEB15 Contents Product overview 2 Camera description 3 Installation 4 Programming 6 Specifications 7 Setup menu

More information

RC300 IntelliFire Plus Multifunction Remote Control Installation & Operating Instructions

RC300 IntelliFire Plus Multifunction Remote Control Installation & Operating Instructions RC300 IntelliFire Plus Multifunction Remote Control Installation & Operating Instructions Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following

More information

Reacti-Therm I and III Heating Modules

Reacti-Therm I and III Heating Modules INSTRUCTIONS Reacti-Therm I and III Heating Modules TS-18822 TS-18824 Number TS-18822 TS-18824 Description Reacti-Therm I Heating Module (single block) Reacti-Therm III Heating Module (triple block) 2101.1

More information

APC BC300 Series 40kW 208/450/480V User Guide

APC BC300 Series 40kW 208/450/480V User Guide APC BC300 Series 40kW 208/450/480V User Guide Copyright 2002 APC Denmark ApS This manual is subject to change without notice and does not represent a commitment on the part of the vendor Thank You Thank

More information

SEE DISCLAIMER ON REVERSE

SEE DISCLAIMER ON REVERSE BOLTEK CORPORATION Lightning Detection GSM-1 Text Message Notification for EFM-100C Electric Field Monitor User Guide SEE DISCLAIMER ON REVERSE BOLTEK LIGHTNING DETECTION GSM-1 Text Message Alert Dialer

More information

COMSPHERE 48 Vdc CENTRAL OFFICE POWER UNIT

COMSPHERE 48 Vdc CENTRAL OFFICE POWER UNIT COMSPHERE 48 Vdc CENTRAL OFFICE POWER UNIT INSTALLATION GUIDE Document No. 3000-A2-GB41-50 October 2002 COMSPHERE 48 Vdc Central Office Power Unit COMSPHERE 48 Vdc Central Office Power Unit Installation

More information

INSTALLATION GUIDE. AXIS A1001 Network Door Controller

INSTALLATION GUIDE. AXIS A1001 Network Door Controller INSTALLATION GUIDE AXIS A1001 Network Door Controller Liability Every care has been taken in the preparation of this document. Please inform your local Axis office of any inaccuracies or omissions. Axis

More information

GigaCore 12. Gigabit Ethernet Switch for the entertainment industry. Quick Start Guide. V2.1.0 Rev5. English

GigaCore 12. Gigabit Ethernet Switch for the entertainment industry. Quick Start Guide. V2.1.0 Rev5. English GigaCore 12 Gigabit Ethernet Switch for the entertainment industry Quick Start Guide V2.1.0 Rev5 English Table of Content Safety Instructions 3 Compliance information 4 Warranty information 5 Registration

More information

KONICA MINOLTA GP-502 OPERATION MANUAL

KONICA MINOLTA GP-502 OPERATION MANUAL KONICA MINOLTA GP-502 OPERATION MANUAL Rev 1.0 February 2012 Table of Contents 1. Safety 2. Overview 2.1 Features & Benefits of GP-502 2.2 Ellipse Binding Elements 2.3 User Interface & Feature Locations

More information

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001 SLATE Base Module R8001A1001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform can

More information

Agilent N4011A MIMO/Multi-port Adapter

Agilent N4011A MIMO/Multi-port Adapter Agilent N4011A MIMO/Multi-port Adapter Getting Started Guide Agilent Technologies Notices Agilent Technologies UK Ltd. 2007, 2009 No part of this manual may be reproduced in any form or by any means (including

More information

Refrigerated Incubator Model and Operating Instructions

Refrigerated Incubator Model and Operating Instructions Refrigerated Incubator Model 165000 and 165000-2 Operating Instructions N2400379 - Rev. 1 08May2018 1 Contents 1. SAFETY...3 1.1. EMF INTERFERENCE...4 1. PRODUCT INFORMATION...5 1.1 INTRODUCTION...5 2.

More information

Installation Instructions

Installation Instructions 2 or 4 pipe systems model T701DFP-1 Fan Coil Thermostat 7-Day Programmable Thermostat Remote sensor ready Self-prompting programming Auto 2-pipe changeover when used with accessory changeover sensor Dry

More information

Operation and Maintenance Manual

Operation and Maintenance Manual M0075640-01 (en-us) September 2016 Operation and Maintenance Manual Product Link PLG641 and PLG601 for Generator Systems PL6 1-UP (Machine Control & Guidance Products) SAFETY.CAT.COM Important Safety Information

More information

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE K3179V2 2/11 Rev. A ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE FEATURES The ADEMCO 4208SNF Universal Class A Module can be used in either of two different applications.

More information

Reacti-Therm I and III Heating/Stirring Modules

Reacti-Therm I and III Heating/Stirring Modules INSTRUCTIONS Reacti-Therm I and III Heating/Stirring Modules TS-18821 TS-18823 Number TS-18821 TS-18823 Description Reacti-Therm I Heating/Stirring Module (single block) Reacti-Therm III Heating/Stirring

More information

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date:

Installation and Operating instructions for. C9900-U battery pack. Version: 2.0 Date: Installation and Operating instructions for C9900-U330-0010 battery pack Version: 2.0 Date: 2017-03-23 Table of contents Table of contents 1 Foreword 3 1.1 Notes on the Documentation 3 1.1.1 Liability

More information

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions DT00 DT00-R DT0 DT0-R IFS Fiber Module Installation & Operation Instructions DR00 DR00-R DR00 DR00-R P/N 0 REV B ISS 0AUG DT00 CONTACT WHEN ON CHANNEL CONTACT TRANSMITTER ifs International Fiber Systems

More information

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions VT9930WDM VT9930WDM-R3 VR9930WDM VR9930WDM-R3 IFS Fiber Module Installation & Operation Instructions P/N 1062791 REV B ISS 01JUL11 VT/VR9930WDM RS - 232 DATA 1 2 3 4 5 6 7 8 20 Data Input Data Output Ground

More information

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Operations Manual TS400. Test Station for G450/G460 Gas Detector TS400 Test Station for G450/G460 Gas Detector Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.goodforgas.com GfG Products for Increased Safety Congratulations

More information

Disclaimer. Trademarks. Copyright. Warranty

Disclaimer. Trademarks. Copyright. Warranty 1 Disclaimer Trademarks Copyright Control4 makes no representations or warranties with respect to any Control4 hardware, software, or the contents or use of this publication, and specifically disclaims

More information

Product Holding Device

Product Holding Device Product Holding Device Installation, Operation, Service, and Parts Manual Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians. JANUARY

More information

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions VT6010 VT6010-R3 VR6010 VR6010-R3 IFS Fiber Module Installation & Operation Instructions P/N 1062796 REV B ISS 01JUL11 4 BNC Cables (Input from cameras) VT6010A 4 CHANNEL VIDEO TRANSMITTER 1-2 - VIDEO

More information

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions VAT1200 VAT1200-R3 VAR1200 VAR1200-R3 IFS Fiber Module Installation & Operation Instructions P/N 1062830 REV B ISS 01JUL11 NOTE: For an unbalanced audio input connection tie pin 1 to pin 2 and utilize

More information

Corning LSE 6L Digital Water Bath

Corning LSE 6L Digital Water Bath Corning LSE 6L Digital Water Bath INSTRUCTION MANUAL Models 6783 (120V US) 6784 (230V EU) Table of Contents 1.0 Warning 1 2.0 Safety Information 1 3.0 Package Contents 1 4.0 Unpacking 2 5.0 Installation

More information

Hydrogen Generator Model HPNM 1. Instruction manual. 166 Keystone Drive Montgomeryville, PA Phone: Fax:

Hydrogen Generator Model HPNM 1. Instruction manual. 166 Keystone Drive Montgomeryville, PA Phone: Fax: Hydrogen Generator Model HPNM 1 Instruction manual 166 Keystone Drive Montgomeryville, PA 18936 Phone: 215-641-2700 Fax: 215-641-2714 Introduction Index INDEX... 2 INTRODUCTION... 3 SCOPE OF THE MANUAL...

More information

Relay Panel and Relay Panel Module Wiring and installation manual Light is OSRAM

Relay Panel and Relay Panel Module Wiring and installation manual Light is OSRAM www.osram.us/extend Relay Panel and Relay Panel Module Wiring and installation manual Light is OSRAM Overview The Relay Panel is an addressable lighting control panel that fully integrates with the ENCELIUM

More information

Evolve 5.5 cu. ft. Medical-grade Undercounter Refrigerator

Evolve 5.5 cu. ft. Medical-grade Undercounter Refrigerator Evolve 5.5 cu. ft. Medical-grade Undercounter Refrigerator Quick Start Guide Product Features Quiet Operation Temperature Uniformity SilverPoint Enabled Local and Remote Alarms Stable Temperature Control

More information

Homeowner s Installation Instructions & Operating Manual

Homeowner s Installation Instructions & Operating Manual Homeowner s Installation Instructions & Operating Manual ELECTRIC HEATER WITH REMOTE CONTROL Model: GI-32-ZC IS-36-ZC, IS-42-ZC Insert surrounds READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING

More information

TEC2100 Series Networked Thermostats

TEC2100 Series Networked Thermostats Product Bulletin Issue Date February 11, 2004 TEC2100 Series Networked Thermostats The TEC2100 Series of thermostats is a family of highly advanced thermostats specifically designed for control of equipment

More information

field SENSE EC-FS2-001-A

field SENSE EC-FS2-001-A field SENSE EC-FS2-001-A www.fieldsense.com introduction The FieldSENSE 2.0 is the next generation in Personal RF Monitors specifically designed for protecting personnel working near broadcast and telecommunications

More information

Undercounter Refrigerator Operation Manual i.series and Horizon Series

Undercounter Refrigerator Operation Manual i.series and Horizon Series Undercounter Refrigerator Operation Manual i.series and Horizon Series Blood Bank Models i.series: ib105 (Version B) Horizon Series: HB105 (Version B) Laboratory/Pharmacy Models i.series: ilr105 (Version

More information

IntelliDoX Operator Manual

IntelliDoX Operator Manual IntelliDoX Operator Manual OPERATOR MANUAL TABLE OF CONTENTS Table of Contents Table of Contents...1 About this Publication...3 Important Safety Information: Read First...4 Getting Started...5 About the

More information

VT1101M VT1102M IFS Fiber Module Installation & Operation Instructions

VT1101M VT1102M IFS Fiber Module Installation & Operation Instructions VT1101M VT1102M IFS Fiber Module Installation & Operation Instructions P/N 1062814 REV B ISS 01JUL11 Video source Coax cable VT1101M VIDEO TX ifs 3 +9-12VDC 2 GRD 1 Contact input Black with white stripe

More information

Table of Contents. Part I SAFETY MESSAGE TO INSTALLERS OF EMERGENCY WARNING EQUIPMENT 2 Part II Vehicle Operation 4. Part III Safety Messages 13

Table of Contents. Part I SAFETY MESSAGE TO INSTALLERS OF EMERGENCY WARNING EQUIPMENT 2 Part II Vehicle Operation 4. Part III Safety Messages 13 Manual I SS2000 TouchScreen Installation Guide Table of Contents Foreword 0 Part I SAFETY MESSAGE TO INSTALLERS OF EMERGENCY WARNING EQUIPMENT 2 Part II Vehicle Operation 4 1 Installing the... SS2000 TouchScreen

More information

40 Built-in Electric Fireplace Operating and Installation Instructions

40 Built-in Electric Fireplace Operating and Installation Instructions 40 Built-in Electric Fireplace Operating and Installation Instructions This manual is for use with Furrion FF40S15A-BL 40 Built-in Electric Fireplace 1 Welcome Furrion FF40S15A-BL 40 Built-in Electric

More information

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions D1300 D1300-R3 D2300 D2300WDM D2300CP D2300SHR IFS Fiber Module Installation & Operation Instructions P/N 1062852 REV ISS 01AUG11 D1300 / D2300 / D2300SHR 2 - Wire RS485 Connection 4 3 2 1 No Connection

More information

4100U City and Relay Cards Installation Instructions

4100U City and Relay Cards Installation Instructions 4100U City and Relay Cards Installation Instructions Introduction This publication describes the installation procedure for the following: 4100-6031/6032 City Circuit Cards 4100-6033 Alarm Relay Card Inspecting

More information

(Place Logo from Lab here)

(Place Logo from Lab here) Rad-5 & Rad-5v Signal Extraction Pulse Oximeter Service Manual (Place Logo from Lab- 1874 here) Rad-5 & Rad-5v Signal Extraction Pulse Oximeter Service Manual The Rad-5/5v Service Manual is intended to

More information

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions DECT000 DECT00 DECT00 DECR000 DECR00 DECR00 IFS Fiber Module Installation & Operation Instructions P/N 00 REV B ISS 0AUG DECT00 CHANNEL LNK ACT TX RX 00FX CONTACT CLOSED WHEN ON CONTACT TO ETHERNET TRANSMITTER

More information

INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER

INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER 273 Branchport Avenue Long Branch, N.J. 07740 (908) 222-6880 INSTALLATION INSTRUCTIONS MODEL PA-250 AND PA-500 BOOSTER AMPLIFIER GENERAL: The Series PA-250 and PA-500 Watt Booster Amplifiers are designed

More information

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions VAT7420 VAT7420-R3 VAT7430 VAT7430-HP VAT7450 VAT7450-R3 VAT7450-HP IFS Fiber Module Installation & Operation Instructions VAR7420 VAR7420-R3 VAR7430 VAR7430-R3 VAR7450 VAR7450-R3 P/N 1062829 REV B ISS

More information

Pet Immune SAW PIR Motion Sensor

Pet Immune SAW PIR Motion Sensor PET Immune SAW PIR Motion Sensors Installation Sheet Description This is the Installation Sheet for SAW PIR and PET Immune Motion Sensors. See Table 1. Table 1: Motion Sensors 60-807-95R 60-807-01-95R

More information

EW 40 Wireless Fan Control

EW 40 Wireless Fan Control Installation & Operating Manual EW 40 Wireless Fan Control USA CAN Product Information... Chapters 1 + 2 Mechanical Installation... Chapter 3 Electrical Installation... Chapter 4 Start Up and Configuration...

More information

TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series. Installation Guide

TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series. Installation Guide TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series Installation Guide INTRODUCTION Welcome and from all of us at Carrier, thank you for purchasing your new Côr thermostat: the

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS WARNING TO PREVENT FIRE OR SHOCK HAZARD, DO NOT USE THIS PLUG WITH AN EXTENSION CORD, RECEPTACLE OR OTHER OUTLET UNLESS THE BLADES CAN BE FULLY INSERTED TO PREVENT BLADE EXPOSURE. TO PREVENT FIRE OR SHOCK

More information

SAMPLE MANUAL - INSTALLATION - FOR REFERENCE ONLY. ChemScan mini Analyzer. Parameter. Method #### Installation, Operation & Maintenance Manual

SAMPLE MANUAL - INSTALLATION - FOR REFERENCE ONLY. ChemScan mini Analyzer. Parameter. Method #### Installation, Operation & Maintenance Manual Parameter Method ####, Operation & Maintenance Manual Rev 3/26/2018 Contact Information Document Information Customer Name: Plant Name/Location: Date: Analyzer Serial #: ASA, Inc. (Applied Spectrometry

More information

Fuel Management System Setup Guide

Fuel Management System Setup Guide Fuel Management System Setup Guide EVO-EXPC & EVO-EXPC2 Expansion Consoles for TS-5000 evo and TS-550 evo Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel: +1 608 838 8786 800 225 9787

More information

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability Product Bulletin T601DFH-4, T602DFH-4, T603DFH-4, T604DFH-4, T605DFH-4, T601DFH-4+PIR, T602DFH-4+PIR,

More information

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description. USER GUIDE TB-9022 Iron Man Plus Workstation Monitor Installation, Operation and Maintenance Features and Components Made in the United States of America A B C D Figure 1. Iron Man Plus Workstation Monitor

More information

Digital Heat Block User Manual

Digital Heat Block User Manual Digital Heat Block User Manual Quidel Digital Heat Block Page 1 of 10 General Information Quidel Contact Information Contact Quidel Technical Support from 8:00 a.m. to 5:00 p.m. EST Tel: 800.874.1517 (in

More information

IMPORTANT SAFETY INFORMATION! WARNING ALWAYS keep electric cords, home furnishings, drapes, clothing, papers, or other combustibles at least 3 feet (0

IMPORTANT SAFETY INFORMATION! WARNING ALWAYS keep electric cords, home furnishings, drapes, clothing, papers, or other combustibles at least 3 feet (0 Electric Fireplace Factory Model: EF-30D CONSUMER SAFETY INFORMATION Read this manual before installing and operating this appliance Failure to follow these instructions may result in electric shock, fire

More information

Operating instructions

Operating instructions Operating instructions For the operator Operating instructions ecotec plus Gas-fired wall-hung high-efficiency boiler GB, IE Publisher/manufacturer Vaillant GmbH Berghauser Str. 40 D-42859 Remscheid Telefon

More information

Installation and Operation Manual

Installation and Operation Manual 1645 Lemonwood Dr. Santa Paula, CA 93060 USA Toll Free: 1 (800) 253-2363 Tel: 1 (805) 933-9970 Fax: 1 (805) 933-9160 www.thecoolboss.com Cool Boss Portable Evaporative Air Cooler Installation and Operation

More information

Safe Operation Manual. Honeywell IQ Force Gas Detector

Safe Operation Manual. Honeywell IQ Force Gas Detector Safe Operation Manual Honeywell IQ Force Gas Detector Honeywell Analytics 800-663-4164 403-248-9226 Fax 403-575-3708 03JUN2012 P/N 50105843-047 Version 01 http://www.honeywell.com HONEYWELL IQ Force PERSONAL

More information

Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions

Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions Yale Real Living Touchscreen Deadbolt Installation and Programming Instructions x3 #8-32 x 5/16" Machine screws x4 #7 wood & #8-32 machine x 20mm Combination screws x2 M6x47mm Long through bolt 1 Preparing

More information

Homeowner s Installation Instructions & Operating Manual

Homeowner s Installation Instructions & Operating Manual Homeowner s Installation Instructions & Operating Manual ELECTRIC HEATER WITH REMOTE CONTROL Model: EF42D, EF43D, EF44D, EF45D READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE,

More information

User Manual. MS7-H550-Pro MS7-H550-S MS7-Pro MS7-S

User Manual. MS7-H550-Pro MS7-H550-S MS7-Pro MS7-S User Manual MS7-H550-Pro MS7-H550-S MS7-Pro MS7-S LCD Digital 7 Square Hotplate Magnetic Stirrer LED Digital 7 Square Hotplate Magnetic Stirrer LCD Digital 7 Square Plate Magnetic Stirrer Classic 7 Square

More information

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100 GETTING STARTED GUIDE NI 9217 4 RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100 This document explains how to connect to the NI 9217. Note Before you begin, complete the software and hardware installation

More information

SAFEVIEW-MINI2 TRANSILLUMINATOR

SAFEVIEW-MINI2 TRANSILLUMINATOR SAFEVIEW-MINI2 TRANSILLUMINATOR Catalogue No. SAFEVIEW-MINI2 Instruction Manual Packing List BluView Transilluminator 1 Instruction Manual 1 Signed by: Date: Cleaver Scientific is liable for all missing

More information

Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216)

Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216) Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216) Optional Network Module x3 #8-32 x 5/16" Machine screws x4 #7 wood & #8-32 machine x 20mm Combination

More information

TEC210x-2 Series Networked Thermostats

TEC210x-2 Series Networked Thermostats Product Bulletin Issue Date February 1, 2005 TEC210x-2 Series Networked Thermostats The TEC210x-2 Series of thermostats is a family of highly advanced thermostats specifically designed for control of equipment

More information

Mark 25 Ultrapure Water Conductivity Analyzer

Mark 25 Ultrapure Water Conductivity Analyzer Martek Instruments, Inc. Mark 25 Ultrapure Water Conductivity Analyzer Instruction Manual WARRANTY POLICY Unless otherwise stated, MARTEK INSTRUMENTS, INC. warrants this equipment to be free from defects

More information

Infrared Thermometer

Infrared Thermometer 572-2 Infrared Thermometer PN 4307046 March 2013, Rev. 1, 08/13 2013 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their

More information

IFS Fiber Module Installation & Operation

IFS Fiber Module Installation & Operation T1000 T1000-R3 T1020 T1020-R3 T1025 T1025-R3 R1000 R1000-R3 R1030 R1030-R3 R2000 R2000-R3 R2020 R2020-R3 R2025 R2025-R3 R2010WDM R2010WDM-R3 R2010WDMB R2010WDMB-R3 IFS Fiber Module Installation & Operation

More information

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver

PDU Power Distribution Unit for IP-NINJAR. User s Guide Ver Power Distribution Unit for IP-NINJAR PDU-1209 User s Guide Ver. 1.0.0 Thank you for choosing this IDK product. To ensure the best performance of this product, please read this User s Guide fully and carefully

More information

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001 SLATE Sub-Base Module R8001S9001 INSTALLATION INSTRUCTIONS Scan for more information Application SLATE brings configurable safety and programmable logic together into one single platform. The platform

More information

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required)

Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required) Quick Setup Guide Welcome to the World of In-Home Gardening! Simple Steps to Get Your AeroGarden Up and Growing (No Tools Required) Harvest Elite Model number: 100691-PPL / BSS / PCP / PSG Harvest Elite

More information

PTAC WIRELESS KITS (DT01*, DS01*, DD01*) INSTALLATION INSTRUCTIONS

PTAC WIRELESS KITS (DT01*, DS01*, DD01*) INSTALLATION INSTRUCTIONS PTAC WIRELESS KITS (DT01*, DS01*, DD01*) INSTALLATION INSTRUCTIONS AIR CONDITIONING SENSOR DD01* IO-644C~IO-644C~092007~4 DS01* DT01* The following installation instructions are for a typical installation.

More information

User Manual. Dryer Controller M720

User Manual. Dryer Controller M720 User Manual Dryer Controller M720 Hardware version 1.00 Software version 1.00 Preliminary version Manual M720 Dryer controller Page 1 of 42 Document history Preliminary version: - Created in April, 2009

More information

Infrared Thermometer. Getting Started

Infrared Thermometer. Getting Started 572-2 Infrared Thermometer Getting Started PN 4307046 March 2013 2013 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their

More information

P266 Series Single-Phase Condenser Fan Speed Control

P266 Series Single-Phase Condenser Fan Speed Control P266 Series Single-Phase Condenser Fan Speed Control Product Bulletin P266xxx-x Code No. LIT-12011534 Issued June 24, 2009 The P266 Single-Phase Condenser Fan Speed Control is a cost-effective, weather-resistant,

More information

Daytime Fan-Aspirated Radiation Shield Kit Installation Manual

Daytime Fan-Aspirated Radiation Shield Kit Installation Manual Daytime Fan-Aspirated Radiation Shield Kit Installation Manual For Vantage Pro2 & Vantage Pro2 Plus Stations Introduction The instructions describe how to upgrade a non-aspirated Vantage Pro2 radiation

More information

Cisco TelePresence MCU 4200 Series safety and compliance information

Cisco TelePresence MCU 4200 Series safety and compliance information Cisco TelePresence MCU 4200 Series safety and compliance information On this page: Safety information symbols Operating guidelines Safety warnings Technical specifications Compliance information WEEE information

More information

Operating Instructions

Operating Instructions Operating Instructions Low Emissions and High Efficiency Condensing Oil Boiler DANGER! If these instructions are not followed exactly, a fire or explosion may be caused with serious property damage or

More information

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations Model G32-S Model G32-E Disinfection Soak Stations Operator s Manual CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA Tel: 1-800-445-6741 Fax: 1-877-329-2482 Website: WWW.CIVCO.COM Copyright

More information

RCS Refrigerated Cooling System

RCS Refrigerated Cooling System RCS Refrigerated Cooling System Q Series TM Getting Started Guide Revision G Issued January 2004 RCS Q Series Getting Started Guide 1 2001 2004 by TA Instruments Waters LLC 109 Lukens Drive New Castle,

More information

Homeowner s Installation Instructions & Operating Manual

Homeowner s Installation Instructions & Operating Manual Homeowner s Installation Instructions & Operating Manual ELECTRIC HEATER WITH REMOTE CONTROL Model: EF42D, EF43D, EF44D, EF45D READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE,

More information

Alarm System SECURE AS 302

Alarm System SECURE AS 302 Alarm System SECURE AS 302 Operating Manual SECURE Light app now available! Table of Contents Before You Start.................................. 4 User Information....................................4

More information

SCD. SMALL CYLINDER DRYER with Touchscreen Controller INSTRUCTION MANUAL MANUAL NUMBER Issued March 2015

SCD. SMALL CYLINDER DRYER with Touchscreen Controller INSTRUCTION MANUAL MANUAL NUMBER Issued March 2015 SCD SMALL CYLINDER DRYER with Touchscreen Controller INSTRUCTION MANUAL MANUAL NUMBER 21-11-1042 Issued March 2015 Copyright 2015, Galiso, Inc. 22 Ponderosa Ct., Montrose, CO 81401 (970) 249-0233 (800)

More information

California State University Bakersfield Radiation Safety Program Revised November 2017

California State University Bakersfield Radiation Safety Program Revised November 2017 California State University Bakersfield Radiation Safety Program Revised November 2017 THIS PAGE INTENTIONALLY LEFT BLANK 1 Contents 1. INTRODUCTION... 3 2. ACQUISITION... 3 4. STORAGE... 3 5. LABELING...

More information

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm Operating & Maintenance Manual Alert-4 Ethernet LCD Master Alarm w w w. a m i c o. c o m Contents User Responsibility 4 Introduction 4 Features 5 Description of the Alarm 5 Shipment Details 5 The Alarm

More information

Agilent Electronic Crimping and Decapping Tools Operating Guide. Agilent Technologies

Agilent Electronic Crimping and Decapping Tools Operating Guide. Agilent Technologies Agilent Electronic Crimping and Decapping Tools 5190-3188 5190-3189 5190-3190 5190-3191 Operating Guide Agilent Technologies Notices Agilent Technologies, Inc. 2011 No part of this manual may be reproduced

More information

GETTING STARTED GUIDE NI DI, 30 V, Sourcing, 7 μs

GETTING STARTED GUIDE NI DI, 30 V, Sourcing, 7 μs GETTING STARTED GUIDE NI 9426 32 DI, 30 V, Sourcing, 7 μs This document explains how to connect to the NI 9426. Note Before you begin, complete the software and hardware installation procedures in your

More information

MD-MINI Dry Bath. Instruction Manual

MD-MINI Dry Bath. Instruction Manual MD-MINI Dry Bath Instruction Manual Catalog No. MD-MINI www.majorsci.com service@majorsci.com Version 01B Revision on: 2013.07.15 Packing list MD-MINI: 1x MD-MINI Dry Bath 1x MD-MINI Lid 1x Power Cord

More information

INSTRUCTION MANUAL. Stirring hotplate (with probe and stand) Brand : (Dragon laboratory)

INSTRUCTION MANUAL. Stirring hotplate (with probe and stand) Brand : (Dragon laboratory) INSTRUCTION MANUAL Stirring hotplate (with probe and stand) Model : Brand : MS-H280-pro (Dragon laboratory) User Manual MS-H280-Pro MS-PA BlueSpin LED Digital Hotplate Magnetic Stirrer BlueSpin LED Digital

More information

Code 542 Peltier Rack User's Guide

Code 542 Peltier Rack User's Guide Code 542 Peltier Rack User's Guide LT2544/ 1999 Gilson, Inc. All rights reserved June 1999 Table of Contents page Introduction...1-1 Unpacking...1-2 Customer Service...1-3 Technical Specifications...1-4

More information

Installation Manual September Opticom Infrared System. Model 798 Emitter Bezel Mount Kit

Installation Manual September Opticom Infrared System. Model 798 Emitter Bezel Mount Kit Installation Manual September 2009 Opticom Infrared System Model 798 Emitter Bezel Mount Kit Installation i Table of Contents 1 About This Manual... 1 1.1 Purpose of Manual... 1 1.2 Manual Conventions...

More information

Alarm Box. Operation Manual AL Powered by

Alarm Box. Operation Manual AL Powered by Alarm Box Operation Manual AL-1112 Powered by Before reading this manual This is a basic installation and operation manual for use of an IDIS alarm box. Users who are using this product for the first time,

More information

CentreVu Call Management System. Release 3 Version 8 Alarm Origination Manager

CentreVu Call Management System. Release 3 Version 8 Alarm Origination Manager CentreVu Call Management System Release 3 Version 8 Alarm Origination Manager 585-215-884 Comcode 108771197 Issue 1 June 2000 Copyright 2000 Lucent Technologies All Rights Reserved Printed in U.S.A. Notice

More information

Clean Base Automatic Dirt Disposal. For Roomba i Series Robot Vacuums. Owner s Guide

Clean Base Automatic Dirt Disposal. For Roomba i Series Robot Vacuums. Owner s Guide Clean Base Automatic Dirt Disposal For Roomba i Series Robot Vacuums Owner s Guide Safety Information Important Safety Information This owner's guide includes information for Regulatory Model(s): ADE-N1

More information

High Output Vacuum/Pressure Pump

High Output Vacuum/Pressure Pump High Output Vacuum/Pressure Pump User Guide Catalogue Numbers: WP62 115 60 (115 V, 60 Hz) WP62 220 50 (230 V, 50 Hz, 1.1 A) WP62 100 60 (100 V, 50/60 Hz) Notice The information in this document is subject

More information

Installation Instructions

Installation Instructions Installation Instructions S E C U R I T Y S Y S T E M Please refer to the System Installation Manual for information on limitations regarding product use and function and information on the limitations

More information