International Catalog

Size: px
Start display at page:

Download "International Catalog"

Transcription

1 International Catalog Control Panels n Variable Frequency Drives Float Switches n Alarm Systems For Water/Wastewater Pump and Motor Control Visit worldwide link at County Highway 6 n PO Box 1708 n Detroit Lakes, MN USA Phone: n Fax: n customer.service@sjerhombus.com

2 SJE-Rhombus Corporate Headquarters, Detroit Lakes, Minnesota, USA Ashland, Ohio Clearwater, Florida Milford, Ohio New Hope, Minnesota Plymouth, Minnesota Suzhou, China Vacaville, California Since 1975, SJE-Rhombus has become a global leader in the water and wastewater industry by developing innovative control products from eight locations that offer reliability and performance customers can depend on. SJE-Rhombus offers a wide variety of control products for Residential and Commercial markets and serves the Irrigation, Municipal, and Industrial markets under the PRIMEX brand. SJE-Rhombus controls can be found in applications including: Wastewater Lift Stations Sumps Pressure Booster Systems Sewers Treatment Plants Drains Wells Irrigation Systems From control panels utilizing embedded circuit board technology to complete control/monitoring systems designed and built to customer specifications, SJE-Rhombus represents the most reliable integration of engineering and manufacturing in the industry. New product designs endure extensive in-house and field testing before submittal to recognized independent laboratories for safety testing and approval. This commitment to quality ensures customers with a dependable, trouble free product. SJE-Rhombus offers a five-year limited warranty on most products. Learn more at Residential Commercial Irrigation Municipal Industrial

3 TABLE OF CONTENTS CONSTANT PRESSURE CONTROLS & CUSTOMIZED CONTROLS VARIOspeed ECONO 3 VARIOspeed N1 5 VARIOspeed 3R 7 VARIOspeed 3R Duplex 9 VARIOspeed LCD 11 Endura MD Triplex 13 VFDC PRIMEX Industrial and Municipal Customized Controls 16 STANDARD CONTROL PANELS Build-A-Panel Control Panels 17 NEX Series Simplex Control Panels 19 Model Model Model Model Model LA32 29 Model 32XR 31 SJE EMD Series - CE Rated Panels 33 SJE Oil Spotter System 35 ALARM SYSTEMS Tank Alert AB VAC 37 Tank Alert EZ - 120V & 240 VAC 39 Tank Alert EZ (CE) - 120V & 240 VAC 41 Tank Alert XT VAC 43 Tank Alert XT VAC 45 SJE Level Monitor CL 47 PUMP FLOATS SJE Quest Latin American Package 49 SJE Quest and SJE Quest II 51 SJE MicroMaster 53 SJE MicroMaster Plus 53 SJE MicroMaster SPDT 53 SJE PumpMaster WPS 55 SJE PumpMaster 57 SJE PumpMaster Plus 57 SJE PumpMaster SPDT 57 SJE AmpMaster 59 SJE HiTempMaster 61 SJE VerticalMaster II 63 SJE VerticalMaster II Plus 63 CONTROL FLOATS EZconnex Float Switch Connection System 65 SJE MegaMaster (CSA Rated) 67 SJE SignalMaster 69 SJE SignalMaster SPDT 69 SJE MilliAmpMaster 71 Sensor Float 73 Sensor Float Mini 73 SUBMERSIBLE TRANSMITTER Sub-X 75 ACCESSORIES Accessories: Cable Weights, Clamp Assembly, Float Brackets 77 1

4 ORDERING INFORMATION PLACING YOUR ORDER To assist us in delivering the exact product you want, please order by the seven digit part number (for alarms and floats) or by the complete model number (for control panels). If you require special features such as additional cable length or special packaging, contact a customer service representative at SJE-Rhombus. SJE-Rhombus also manufactures additional alarms, floats, control panels, and Engineered Custom panels. Please contact SJE-Rhombus customer service to request a custom quote at , customer.service@sjerhombus.com or visit to learn more about our control panel products. SHIPPING YOUR ORDER Standard catalog items, depending on volume and options, are shipped within seven to ten business days from receipt of necessary documentation. Shipping weights listed in this catalog are estimates only. Actual shipping weights may vary. Please indicate your preferred method of shipment when placing your order. SJE-Rhombus will seek competitive shipping quotes from freight forwarders prior to shipment. If you prefer, you may arrange your own transportation from the SJE-Rhombus factory. WARRANTY POLICY SJE-Rhombus offers an industry-leading five-year limited warranty on most* standard products available in our catalog. For complete terms and conditions, please visit *SJE Quest, Sub-X, various Constant Pressure Controls and Customized Controls (municipal and industrial) carry a warranty as stated/quoted. RETURN POLICY Returned products must be no older than one (1) year from the date of manufacture, un-used, and current production models. Returns of certain models may not be permitted. Returned Materials Authorization (RMA) numbers must be assigned to products being returned for credit. SJE-Rhombus reserves the right to adjust restocking fees or deny return upon inspection of returned products. Return is given in the form of a credit. SJE-Rhombus Corporate County Highway 6, PO Box 1708 Detroit Lakes, MN USA Phone: Fax: customer.service@sjerhombus.com SJE-Rhombus (Suzhou) Co., Ltd. Unit B2-6, District A, Weiting Industrial Workplace No. 9 Weixin Road, Weiting Town, Suzhou Industrial Park Suzhou, Jiangsu Province, , China Phone: Fax: sjesales@sjerhombus.cn customer.service@sjerhombus.com A SJE-Rhombus 02/17

5 VARIOSPEED ECONO Controller Variable Frequency Drive controller in a NEMA 1 enclosure for indoor use. The VARIOspeed ECONO controller is designed to control a three phase pump in constant pressure control applications including booster pump, deep well submersible pump, and irrigation pump applications. As flow and head conditions change in the pumping system, the VFD is able to automatically control the pump speed and maintain a constant discharge pressure. The desired set pressure is entered on the door mounted display. The pressure transducer measures the pump discharge pressure. Not for use with sewage pumps. Constant Pressure Controls Pressure-> Setpoint-> 59.8 PSI 60.0 PSI RUN 54.1 Hz 17.4 A PANEL COMPONENTS 1. Enclosure measures x x cm (12 x 10 x 6 inches) thermoplastic NEMA 1 2. Vents for VFD cooling 3. Variable Frequency Drive DISPLAY FEATURES 4. 4 Line / 20 character display 5. Rotary/Push button for menu navigation and editing 6. Left Arrow button 7. ESC button 8. Run indicator LED 9. Fault indicator LED 10. Off/Auto selector switch FEATURES Low Pressure Alarm (pipe burst or run dry protection) High Pressure protection System Fault Log Standard package includes a PSI pressure transducer 1/4 NPT Male, NEMA 4X rated with 6m (20 ft) cable UL Listed enclosure and VFD One-year limited warranty on pressure transducer Five-year limited warranty on controller SPECIFICATIONS Power: Available HP Range 208V-240V 1.5HP - 3HP Control: P.I.D. control Adjustable electronic overload Auto Start on pressure drop (adjustable) Auto stop on low Hz (No-Flow - sleep mode) Environmental: Operating temperature: -10ºC to 40ºC (14ºF to 104ºF) Storage temperature: -20ºC to 55ºC (-4ºF to 131ºF) Altitude: Maximum of 1000m (3280 ft) above sea level PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 3

6 Constant Pressure Controls VARIOSPEED ECONO Controller Variable Frequency Drive controller in a NEMA 1 enclosure for indoor use. Part Number Description Model Output Amp HP Input Phase Output Phase Ship Weight VARIOspeed ECONO, 240V VS E kg VARIOspeed ECONO, 240V VS E kg NOTE: HP rating is based on standard NEMA B 4-pole motor (used for indication only, use nameplate FLA for sizing). The output voltage of the VFD cannot exceed the incoming voltage. Example: 208V in, 208V out (max). SEE INTERNATIONAL PRICE BOOK FOR LIST PRICE. SELECTING THE CORRECT VFD 1. Determine the voltage available on site. 2. Select a pump with the same voltage (motor must be 3 phase). 3. Check pump motor nameplate Full Load Amps (FLA) for proper VFD sizing. 4. Select a VFD with an output amp rating higher than motor FLA. 5. Use motor Service Factor Amps (SFA) for submersible well pump applications for VFD sizing. PHASE CONVERSION The VFD can be used in applications where three phase power is not available. The drive will convert 208/240V single phase power to 208/240V three phase power. A three phase motor must be used in all cases. MAXIMUM MOTOR CABLE LENGTHS For 208V-240V pumps: 400 ft. For cable lengths greater than 400 ft., use a load reactor. Do not exceed 800 ft. Pressure Booster Pump Application Deep Well Pump Application 4 customer.service@sjerhombus.com A SJE-Rhombus 02/17

7 VARIOSPEED N1 Controller Variable Frequency Drive controller in a NEMA 1 enclosure for indoor use. The VARIOspeed N1 controller is designed to control a three phase pump in constant pressure control applications including booster pump, deep well submersible pump, and irrigation pump applications. As flow and head conditions change in the pumping system, the VFD is able to automatically control the pump speed and maintain a constant discharge pressure. The desired set pressure is entered on the door mounted display. The pressure transducer measures the pump discharge pressure. Not for use with sewage pumps. Constant Pressure Controls PANEL COMPONENTS 1. Enclosure (up to 5 HP) measures x x cm (14 x 8 x 8 inches) steel NEMA 1 with locking latch Enclosure (above 5 HP) measures x x cm (18 x 10 x 10 inches) steel NEMA 1 with locking latch 2. Vents for VFD cooling 3. Variable Frequency Drive DISPLAY FEATURES 4. 4 Line / 20 character display 5. Rotary/Push button for menu navigation and editing 6. Left Arrow button 7. ESC button 8. Run indicator LED 9. Fault indicator LED 10. Off/Auto selector switch FEATURES Low Pressure Alarm (pipe burst or run dry protection) High Pressure protection System Fault Log Standard package includes a PSI pressure transducer 1/4 NPT Male, NEMA 4X rated with 6m (20 ft) cable One-year limited warranty on pressure transducer SPECIFICATIONS Power: Available HP Range 208V-240V 1.5HP - 20 HP 480V 7.5HP - 20HP Control: P.I.D. control Adjustable electronic overload Auto Start on pressure drop (adjustable) Auto stop on low Hz (No-Flow - sleep mode) Environmental: Operating temperature: -10ºC to 40ºC (14ºF to 104ºF) Storage temperature: -20ºC to 55ºC (-4ºF to 131ºF) Altitude: Maximum of 1000m (3280 ft) above sea level Pressure Booster Pump Application PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 5

8 Constant Pressure Controls Variable Frequency Drive controller in a NEMA 1 enclosure for indoor use. Part Number Description Model Output Amp HP Input Phase Output Phase Ship Weight VARIOspeed N1, 240V VS N kg VARIOspeed N1, 240V VS N kg VARIOspeed N1, 240V VS N kg VARIOspeed N1, 240V VS N kg VARIOspeed N1, 240V VS N kg VARIOspeed N1, 240V VS N kg VARIOspeed N1, 480V VS N kg VARIOspeed N1, 480V VS N kg NOTE: HP rating is based on standard NEMA B 4-pole motor (used for indication only, use nameplate FLA for sizing). The output voltage of the VFD cannot exceed the incoming voltage. Example: 208V in, 208V out (max). SEE INTERNATIONAL PRICE BOOK FOR LIST PRICE. SELECTING THE CORRECT VFD VARIOSPEED N1 Controller 1. Determine the voltage available on site. 2. Select a pump with the same voltage (motor must be 3 phase). 3. Check pump motor nameplate Full Load Amps (FLA) for proper VFD sizing. 4. Select a VFD with an output amp rating higher than motor FLA. 5. Use motor Service Factor Amps (SFA) for submersible well pump applications for VFD sizing. PHASE CONVERSION* It is possible to supply single phase 240V input power to VS23 models. The VFD output amp must be derated by 50%. Example: The VS N1 will be derated to 22.5A output (max). *Use three-phase input power if available. VS23 VFD s are not UL listed with single-phase supply. Always use a 3 phase motor. MAXIMUM MOTOR CABLE LENGTHS For 208V-240V pumps: 400 ft. For cable lengths greater than 400 ft., use a load reactor. Do not exceed 800 ft. For 480V pumps: 50 ft. For cable lengths greater than 50 ft., use a load reactor. Do not exceed 300 ft. LINE/LOAD REACTORS (Indoor/Outdoor rated. Supplied separately.) A Line reactor is connected between the line power and VFD input. It is used for VFD protection and noise reduction. A Load Reactor is connected between the VFD output and the motor. It is used for motor protection and noise reduction. Mount reactors as close as possible to the VFD. Reactors will increase voltage drop and may impact pump performance. Consult factory for selection. Part Number Line/Load Reactors Use With Model Dimensions (Inches) Electrical Data Ship Weight LR N3R VS N1, VS N1, VS N1 12x12x10 18A, 1.5mH kg LR N3R VS N1, VS N1 12x12x10 55A, 0.27mH kg LR N3R VS N1 12x12x10 83A, 0.17mH kg LR N3R VS N1 12x12x10 21A, 1.8mH kg LR N3R VS N1 12x12x10 35A, 0.71mH kg 6 customer.service@sjerhombus.com A SJE-Rhombus 02/17

9 VARIOSPEED 3R Control Panel Variable Frequency Drive controller in a NEMA 3R enclosure for outdoor or indoor use. The VARIOspeed 3R controller is designed to control a three phase pump in constant pressure control applications including booster pump, deep well submersible pump, and irrigation pump applications. As flow and head conditions change in the pumping system, the VFD is able to automatically control the pump speed and maintain a constant discharge pressure. The desired set pressure is entered on the door mounted display. The pressure transducer measures the pump discharge pressure. Not for use with sewage pumps. Constant Pressure Controls PANEL COMPONENTS 1. Enclosure measures x x cm (18 x 16 x 10 inches) fiberglass NEMA 3R for indoor or outdoor use with removable mounting feet & locking latch 2. Vents for VFD cooling 3. Fan and Thermostat for 7.5 HP and larger HP models 4. Raised Terminals for easy field connections 5. Circuit Breaker Disconnect 6. Variable Frequency Drive 7. Fan Control Circuit Breaker (230V models only) 8. Control Transformer (480V models only - not shown) DISPLAY FEATURES 9. 4 Line / 20 character display 10. Rotary/Push button for menu navigation and editing 11. Left Arrow button 12. ESC button 13. Run indicator LED 14. Fault indicator LED 15. Off/Auto selector switch FEATURES Low Pressure Alarm (pipe burst or run dry protection) High Pressure protection System Fault Log Standard package includes a PSI pressure transducer 1/4 NPT Male, NEMA 4X rated with 6m (20 ft) cable One-year limited warranty on pressure transducer SPECIFICATIONS Power: Available HP Range 208V-240V 1.5HP - 20 HP, 480V 7.5HP - 20HP Control: P.I.D. control Adjustable electronic overload Auto Start on pressure drop (adjustable) Auto stop on low Hz (No-Flow - sleep mode) Environmental: Operating temperature: -10ºC to 40ºC (14ºF to 104ºF) Storage temperature: -20ºC to 55ºC (-4ºF to 131º) Altitude: Maximum of 1000m (3280 ft) above sea level Pressure Booster Pump Application PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 7

10 Constant Pressure Controls Variable Frequency Drive controller in a NEMA 3R enclosure for outdoor or indoor use. Part Number Description Model Output Amp HP Input Phase Output Phase Ship Weight VARIOspeed 3R, 240V VS R kg VARIOspeed 3R, 240V VS R kg VARIOspeed 3R, 240V VS R kg VARIOspeed 3R, 240V VS R kg VARIOspeed 3R, 240V VS R kg VARIOspeed 3R, 240V VS R kg VARIOspeed 3R, 480V VS R kg VARIOspeed 3R, 480V VS R kg NOTE: HP rating is based on standard NEMA B 4-pole motor (used for indication only, use nameplate FLA for sizing). The output voltage of the VFD cannot exceed the incoming voltage. Example: 208V in, 208V out (max). SEE INTERNATIONAL PRICE BOOK FOR LIST PRICE. SELECTING THE CORRECT VFD VARIOSPEED 3R Control Panel 1. Determine the voltage available on site. 2. Select a pump with the same voltage (motor must be 3 phase). 3. Check pump motor nameplate Full Load Amps (FLA) for proper VFD sizing. 4. Select a VFD with an output amp rating higher than motor FLA. 5. Use motor Service Factor Amps (SFA) for submersible well pump applications for VFD sizing. PHASE CONVERSION* It is possible to supply single phase 240V input power to VS23 models. The VFD output amp must be derated by 50%. Example: The VS N1 will be derated to 22.5A output (max). *Use three-phase input power if available. VS23 VFD s are not UL listed with single-phase supply. Always use a 3 phase motor. MAXIMUM MOTOR CABLE LENGTHS For 208V-240V pumps: 400 ft. For cable lengths greater than 400 ft., use a load reactor. Do not exceed 800 ft. For 480V pumps: 50 ft. For cable lengths greater than 50 ft., use a load reactor. Do not exceed 300 ft. LINE/LOAD REACTORS (Indoor/Outdoor rated. Supplied separately.) A Line reactor is connected between the line power and VFD input. It is used for VFD protection and noise reduction. A Load Reactor is connected between the VFD output and the motor. It is used for motor protection and noise reduction. Mount reactors as close as possible to the VFD. Reactors will increase voltage drop and may impact pump performance. Consult factory for selection. Part Number Line/Load Reactors Use With Model Dimensions (Inches) Electrical Data Ship Weight LR N3R VS R, VS R, VS R 12x12x10 18A, 1.5mH kg LR N3R VS R, VS R 12x12x10 55A, 0.27mH kg LR N3R VS R 12x12x10 83A, 0.17mH kg LR N3R VS R 12x12x10 21A, 1.8mH kg LR N3R VS R 12x12x10 35A, 0.71mH kg 8 customer.service@sjerhombus.com A SJE-Rhombus 02/17

11 VARIOSPEED 3R Duplex Control Panel Duplex Variable Frequency Drive controller in a NEMA 3R enclosure for outdoor or indoor use. The VARIOspeed 3R duplex controller is designed to control two three phase pump in constant pressure control applications including booster pump, deep well submersible pump, and irrigation pump applications. As flow and head conditions change in the pumping system, the VFD is able to automatically control the pump speed and maintain a constant discharge pressure. Constant Pressure Controls 8 9 PANEL COMPONENTS 1. Enclosure measures 61 x 51 x 21 cm (24 x 20 x 8 inches) steel (up to 5 HP) and 77 x 61 x 26 cm (30 x 24 x 10 inches) steel ( HP). NEMA 3R for indoor or outdoor use 2. Vents for VFD cooling 3. Fan and Thermostat 4. Field Wiring Terminals for easy field connections 5. Circuit Breaker Disconnects (240V models only), Fuses (480V models only - not shown) 6. Variable Frequency Drives 7. Fan Control Circuit Breaker (240V models only) 8. Pump Run Lights 9. Hand/Off/Auto selector switches NOTE: 480V models include a Control Transformer DISPLAY FEATURES Line / 20 character display 11. Rotary/Push button for menu navigation and editing 12. Left Arrow button 13. ESC button 14. Run indicator LEDs 15. Fault indicator LED FEATURES Low Pressure Alarm (pipe burst or run dry protection) High Pressure protection System Fault Log Standard package includes a PSI pressure transducer 1/4 NPT Male, NEMA 4X rated with 6m (20 ft) cable One-year limited warranty on pressure transducer SPECIFICATIONS Power: Available HP Range 208V-240V 1.5HP - 20 HP, 480V 7.5HP - 20HP Control: P.I.D. control Adjustable electronic overload Auto Start on pressure drop (adjustable) Auto stop on low Hz (No-Flow - sleep mode) Lead/Lag operation Auto alternation on Run Time Environmental: Operating temperature: -10ºC to 40ºC (14ºF to 104ºF) Storage temperature: -20ºC to 55ºC (-4ºF to 131º) Altitude: Maximum of 1000m (3280 ft) above sea level V Model Shown Pressure Booster Pump Application PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 9

12 Constant Pressure Controls VARIOSPEED 3R Duplex Control Panel Variable Frequency Drive controller in a NEMA 3R enclosure for outdoor or indoor use. Part Number Description Model Output Amp HP Input Phase Output Phase Ship Weight VARIOspeed 3RD, 240V VS N3RD kg VARIOspeed 3RD, 240V VS N3RD kg VARIOspeed 3RD, 240V VS N3RD kg VARIOspeed 3RD, 240V VS N3RD kg VARIOspeed 3RD, 240V VS N3RD kg VARIOspeed 3RD, 240V VS N3RD kg VARIOspeed 3RD, 480V VS N3RD kg VARIOspeed 3RD, 480V VS N3RD kg NOTE: HP rating is based on standard NEMA B 4-pole motor (used for indication only, use nameplate FLA for sizing). The output voltage of the VFD cannot exceed the incoming voltage. Example: 208V in, 208V out (max). SEE INTERNATIONAL PRICE BOOK FOR LIST PRICE. SELECTING THE CORRECT VFD 1. Determine the voltage available on site. 2. Select pumps with the same voltage (motor must be 3 phase). 3. Check pump motor nameplate Full Load Amps (FLA) for proper VFD sizing. 4. Select a VFD with an output amp rating higher than motor FLA. 5. Use motor Service Factor Amps (SFA) for submersible well pump applications for VFD sizing. PHASE CONVERSION* It is possible to supply single phase 240V input power to VS23 models. The VFD output amp must be derated by 50%. Example: The VS N3RD will be derated to 22.5A output (max). *Use three-phase input power if available. VS23 VFD s are not UL listed with single-phase supply. Always use a 3 phase motor. MAXIMUM MOTOR CABLE LENGTHS For 208V-240V pumps: 400 ft. For cable lengths greater than 400 ft., use a load reactor for each pump. Do not exceed 800 ft. For 480V pumps: 50 ft. For cable lengths greater than 50 ft., use a load reactor for each pump. Do not exceed 300 ft customer.service@sjerhombus.com A SJE-Rhombus 02/17

13 14:33 14:32 PIDval2 61.7PSI Hz Out 57.63Hz 0.00Hz I Out 0.00A STF FWD STOP EXT PREV SET NEXT HAND OFF AUTO Risk of injury and electric shock WARNING Metal Surface May Get Hot Risk of Burn Read the manual and follow the safety instruction before use. Isolate from supply and wait 10 minutes before removing this cover. Ensure proper earth connection. CAUTION Risk of Fire Mount the Inverter on a non-combustible surface. Il y a un risque de se faire mal et de recevoir une déscharge électrique WARNING Surface de métal peut devenir chaud-risqu de Brûlures Avant de l utiliser il faut lire le manual e il faut suivre les instrictions de sécurité L isoler les matéraux électriques et attendre dix minutes avant d enlever la couverture Assurer la propre connection mise à la terre AVERTISSEMENT Il y a un risque d un feu Montez non-combustible le veriateur de vitesse sur une surface 適切なアース接続を確認してください注意 火災の危険性不燃性の表面上にインバータをマウント ケガ感電の危険性警告 バーンのリスク - 金属表面は ホットを得ることができます 取扱説明書を読み 安全に従ってください使用前に命令電源から切り離し このカバーを取り外す前に10 分待ちます適切なアース接続を確認してください 注意 火災の危険性不燃性の表面上にインバータをマウント PULL 14:33 14:32 PIDval2 61.7PSI Hz Out 57.63Hz 0.00Hz I Out 0.00A STF FWD STOP EXT PREV SET NEXT HAND OFF AUTO Risk of injury and electric shock WARNING Metal Surface May Get Hot Risk of Burn Read the manual and follow the safety instruction before use. Isolate from supply and wait 10 minutes before removing this cover. Ensure proper earth connection. CAUTION Risk of Fire Mount the Inverter on a non-combustible surface. Il y a un risque de se faire mal et de recevoir une déscharge électrique WARNING Surface de métal peut devenir chaud-risqu de Brûlures Avant de l utiliser il faut lire le manual e il faut suivre les instrictions de sécurité L isoler les matéraux électriques et attendre dix minutes avant d enlever la couverture Assurer la propre connection mise à la terre AVERTISSEMENT Il y a un risque d un feu Montez non-combustible le veriateur de vitesse sur une surface 適切なアース接続を確認してください注意 火災の危険性不燃性の表面上にインバータをマウント ケガ感電の危険性警告 バーンのリスク - 金属表面は ホットを得ることができます 取扱説明書を読み 安全に従ってください使用前に命令電源から切り離し このカバーを取り外す前に10 分待ちます適切なアース接続を確認してください 注意 火災の危険性不燃性の表面上にインバータをマウント PULL VARIOSPEED LCD DRIVE Variable Frequency Drive for pressure control applications. The VARIOspeed LCD Drive has been factory pre-programmed for specific pressure control applications. Constant Pressure Controls As flow and head conditions change in the pumping system, the VARIOspeed LCD Drive is able to automatically control the pump speed and maintain a constant discharge pressure. The desired set pressure is set on the VFD keypad. The pressure transducer measures the pump discharge pressure. FEATURES Power Available HP range ( V) 5 HP - 40 HP ( V) 5 HP - 50 HP Models available for single phase or three phase supply voltage UL Listed for single phase or three phase supply voltage Energy optimization control Control PID control Hand/Off/Auto selector switch Adjustable electronic overload PSI transducer (4-20 ma signal) Auto Start on pressure drop (adjustable) Auto Stop on No-flow (sleep mode) Pre-charge control (gradual pipe pressurization) High and low pressure alarms Automatic system restart Low water shutdown digital input 2 relay outputs 2 analog outputs Modbus RTU communication (RS-485) One-year limited warranty USER FRIENDLY VARIOSPEED LCD DISPLAY: Pressure Booster Pump Application VARIOspeed LCD ケガ感電の危険性警告 バーンのリスク - 金属表面は ホットを得ることができます取扱説明書を読み 安全に従ってください使用前に命令電源から切り離し このカバーを取り外す前に10 分待ちます Deep Well Submersible Pump Application DISPLAY: Monitor Backlit LCD VARIOspeed LCD MENU: Displays parameters and drive data ケガ感電の危険性警告 バーンのリスク - 金属表面は ホットを得ることができます取扱説明書を読み 安全に従ってください使用前に命令電源から切り離し このカバーを取り外す前に10 分待ちます FUNCTION KEYS: Navigate through parameters, monitored data, and save changes SETTING DIAL: Scroll through parameter list and edit parameter value PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 11

14 Constant Pressure Controls VARIOSPEED LCD DRIVE Variable Frequency Drive for pressure control applications. Part Number Model Motor Max Amps (1) Motor HP (2) (approx) Enclosure Rating V, Three Phase Incoming Power V LCD NEMA 1 (indoor) V LCD NEMA 1 (indoor) V LCD NEMA 1 (indoor) V LCD NEMA 1 (indoor) V LCD NEMA 1 (indoor) V LCD NEMA 1 (indoor) V LCD NEMA 1 (indoor) V LCD NEMA 1 (indoor) V, Single Phase Incoming Power V LCD NEMA 1 (indoor) V LCD NEMA 1 (indoor) V LCD NEMA 1 (indoor) V LCD NEMA 1 (indoor) V LCD NEMA 1 (indoor) V LCD NEMA 1 (indoor) V, Three Phase Incoming Power V LCD NEMA 1 (indoor) V LCD NEMA 1 (indoor) V LCD NEMA 1 (indoor) V LCD /20 NEMA 1 (indoor) V LCD NEMA 1 (indoor) V LCD NEMA 1 (indoor) V LCD NEMA 1 (indoor) V LCD NEMA 1 (indoor) Larger horsepower models and engineered solutions are available upon request. (1) Check motor max amps for proper drive sizing. Drive Output Current rating must be greater than motor max amps. (2) Horsepower rating is based on standard NEMA B 4-pole motor (used for indication only, use motor max amps for sizing). Note: The output voltage of the VARIOspeed LCD VFD cannot exceed the incoming power. Example: 208V in, 208V out customer.service@sjerhombus.com A SJE-Rhombus 02/17

15 ENDURA MD Triplex Booster Control Panel Triplex Pressure Booster Control Panel. The Endura MD triplex booster control panel features the VFDC-4100 controller for commercial pressure booster applications using (3) Variable Frequency Drives (VFDs). Constant Pressure Controls STANDARD CONTROL PANEL FEATURES Painted steel, wall mounted single door enclosure; NEMA 1 indoor rated (2) cooling fans with filters and adjustable thermostat VFDC-4100 controller Graphic screen display with LED back light 4 arrow buttons for easy navigation and setup System status display: operating pressure, set pressure, time/date, alarm with time date Pump status display: pumps in use, lead pump, pump run/stop, pump speed, VFD fault, hour meter for each pump Automatic alternation (cycle or timed based) Password protection Panel mounted Variable Frequency Drive (VFD) for each pump Circuit breaker disconnect for each pump 22mm Hand/Off/Auto switches for each pump 22mm General Alarm red indicator activates on: Pump fault High pressure fault Low suction pressure fault 24 VDC power supply - NEC Class 2 operating overcurrent protection Multi-tap 150 VA transformer 480/240/208:120 VAC Terminal blocks for: Main power Pumps Pressure transmitter Low suction pressure switch Remote enable Auxiliary alarm contacts UL 508A Listed PSI pressure transmitter with 6m (20ft) cable OPTIONS Main circuit breaker disconnect with a through door disconnect mechanism - consult factory for pricing Model Shown EN43-9.5MDT with Optional Disconnect PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 13

16 Constant Pressure Controls ENDURA MD Triplex Booster Control Panel Part Number Description Model Triplex Pressure Booster Control Panel. Output Amp HP Input Phase Output Phase Panel Weight Endura MD Triplex 240V EN MDT kg Endura MD Triplex 240V EN MDT kg Endura MD Triplex 240V EN MDT kg Endura MD Triplex 240V EN MDT kg Endura MD Triplex 240V EN MDT kg Endura MD Triplex 480V EN MDT kg Endura MD Triplex 480V EN MDT kg Endura MD Triplex 480V EN MDT kg Endura MD Triplex 480V EN MDT kg Endura MD Triplex 480V EN MDT kg Use motor full load amps (FLA) and voltage to select part number and model customer.service@sjerhombus.com A SJE-Rhombus 02/17

17 VFDC - 4I00 Controller Microprocessor-based controller for constant pressure applications. The VFDC-4100 controller is a microprocessor-based controller specifically designed for constant pressure applications using 1-4 variable frequency drives. It features P.I.D. control, automatic alternation, data logging, and communication capabilities. A backlit graphic display allows users to monitor pressure, pump speeds and alarm status. The VFDC-4100 controller uses a menu driven setup that makes navigation and configuration fast and simple. FEATURES 1 to 4 VFD operation P.I.D. control Graphic screen display with LED back-lighting System status display Operating pressure Set Pressure Time and date Alarm with time and date Pump status display Pumps in use Lead pump Pump run/stop Pump speed VFD fault Hour meter for each pump Four arrow buttons for easy navigation and setup Automatic alternation (cycle-based or time-based) 13 programmable digital outputs Scheduled pressure setup function Jockey pump operation (smaller lead pump) Pressure transmitter setup RS232 Modbus Serial communication High and low pressure alarms Low suction pressure/low level with programmable restart One-year limited warranty. 4 Pump Control Configuration Deep Well Submersible Pump Application Customized Controls PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 15

18 CUSTOMIZED CONTROLS Industrial and Municipal - PRIMEX Customized Controls FEATURES Variable Frequency Drives Reduced voltage starters Programmable Logic Controllers (PLC) Service entrance rating Manual transfer switch gear SCADA systems Operator interface (HMI) Remote monitoring Telemetry/alarm dialers Multiple pump control User specified components Voltage/current meters Line and load reactors Third party approvals: UL508A, UL698A, ULNNNY, cul Certification PUMP WATCH Comprehensive cloud based monitoring systems designed for wastewater pump stations and other applications. The Pump Watch family offers a simple and effective tool for management of wastewater or water collection systems via a cellular network. Alarms are monitored and service personnel notified in the event of failure. Data logging and trending of critical information enables users to visually track system performance and recognize impending problems. Station data can be seen in a simple and intuitive format from a web browser on a PC, tablet or smartphone. Station View Controller Modbus Pump Watch Gateway FAMILY FEATURES Utilizes cellular networks (CDMA; GSM optional) Alarm notifications via and text messaging (SMS) Battery backup Pump Watch designed specifically for municipal lift stations Pump Watch Multi designed for pumping or nonpumping applications Pump Watch Express designed for basic monitoring of standard lift stations Critical System Parameters customer.service@sjerhombus.com A SJE-Rhomb us 02/17

19 BUILD-A-PANEL CONTROL PANELS Build-A-Panel control panels provide greater flexibility by ordering through options. SJE-Rhombus Build-A-Panel control panels offer pump control and alarm notification in one convenient package for a variety of pumping applications including pump chambers, sump pump basins, irrigation systems, lift stations and more. Each Build-A-Panel control panel comes complete with float switches, electrical schematics, installation instructions and are backed by a five-year limited warranty. Visit to view our full line of Build-A-Panel options. INSTALLER FRIENDLY SERIES The Installer Friendly Series control panels utilize electronic technology to provide greater control of pumping systems via a simple-to-use touch pad on the inner door for programming and monitoring pump and float operations. UL/cUL Listed CAPACITOR START/RUN SJE-Rhombus offers motor control panels designed specifically for grinder pump applications or other pumps requiring external motor starter kits. Common applications include pump chambers and lift stations. UL/cUL Listed. Single Phase Simplex (113) Single Phase Duplex (123) INTRINSICALLY SAFE Intrinsically safe Build-A-Panel control panels are designed for applications requiring intrinsically safe float circuits or other circuit extensions. Single Phase Simplex I.S (114) Single Phase Duplex I.S (124) Three Phase Simplex I.S (314) Three Phase Duplex I.S (324) Standard Control Panels DEMAND DOSE TIMED DOSE Touch Pad Display Features: Easy programming for pump control Pump run indicator(s) Float status indicators, including float out-of-sequence alarm HOA pump control switch(es) 6 digit LED display includes: Elapsed time meter(s) Cycle counter(s) Alarm counter Lead/lag selector toggles pump operation in duplex models Float error counter Override counter in timed dose models FLOATLESS TECHNOLOGY In addition to floats, all IFS panels are available with the C-Level floatless sensor: Uses pressure to detect liquid level in tank and send signal to the IFS panel Compact design; low voltage Easy to adjust set points One sensor replaces up to 4 floats CL40 (range up to cm) or CL100 (range up to 254cm) models available SELECT START STARTER BOXES The Select Start three phase starter boxes provide a reliable means of controlling a 208/240/480V, or 575V three phase motor in pump chambers, sump pump basins, irrigation systems, lift stations and air compressor systems. The starter boxes utilize a float switch to activate the combination motor controller to turn the motor on and off. Single Phase, 240V Three Phase, 208V, 240V, 480V, or 575V Phone: Fax: customer.service@sjerhombus.com 17

20 NOTES: Standard Control Panels A SJE-Rhombus 02/17

21 NEX Series Single Phase Simplex Control Panel Single phase, simplex motor contactor control. The NEX Series control panel is designed to control one single phase pump in water and wastewater applications. Two control switches activate a power relay to turn the pump on and off. If an alarm condition occurs, an additional alarm switch activates the audible/visual alarm system. The compact design (20.32 x x cm) is ideal for residential applications. Universal pump voltage and control/alarm power allow the NEX Series panel to handle three voltages (120/208/240V single phase). The innovative design of internal components and integral mounting tabs make installation quick and simple Standard Control Panels PANEL COMPONENTS 1. Enclosure measures X X cm (8 x 6 x 4 inches) NEMA 4X (ultraviolet stabilized thermoplastic) for indoor or outdoor use. 2. Padlockable Latch 3. Integral Mounting Feet 4. Power Relay controls pump by switching electrical lines. 5. HOA Switch for manual pump control. 6. Green Pump Run Indicator Light 7. Field Wiring Terminal Block 8. Control/Alarm Fuses 9. Control/Alarm Power Indicator 10. Ground Lug 11. Circuit Breaker provides pump disconnect and branch circuit protection. 12. Float Status Indicator Lights (Stop and Start Float Status) STANDARD ALARM PACKAGE 13. Red Alarm Beacon provides 360 o visual check of alarm condition. 14. Auxiliary Alarm Contacts (Form C) are provided for signaling an external device. 15. Alarm Horn provides audible warning of alarm condition, 85 to 90 decibel rating (not shown). 16. Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in an alarm condition. Alarm automatically resets once alarm condition has been cleared (not shown). SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING. 3 PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 19

22 NEX Series Single Phase Simplex Control Panel ORDERING INFORMATION Single phase, simplex motor contactor control. Part # Description Amps Ship Weight NEX Series Single Phase Simplex, 120/208/240V, (3) 6 meter (20 ft) SJE SignalMaster control float switches kg NEX Series Single Phase Simplex, 120/208/240V, (3) 6 meter (20 ft) SJE SignalMaster control float switches kg NEX Series Single Phase Simplex, 120/208/240V, no float switches kg NEX Series Single Phase Simplex, 120/208/240V, no float switches kg Standard Control Panels SEE INTERNATIONAL PRICEBOOK FOR LIST PRICING. SPECIFICATIONS Voltage Supply: Pump: 120/208/240V single phase, 50/60 Hz Control/Alarm: 120/208/240V single phase, 50/60 Hz Enclosure: x x cm (8 x 6 x 4 inches), padlockable NEMA 4X (ultraviolet stabilized thermoplastic with integral mounting feet for outdoor or indoor use) Float Control Voltage: 12 VDC Pump Amps: 0-12 amps; 9-20 amps Auxiliary Alarm Contacts: Form C, 120V Max customer.service@sjerhombus.com A SJE-Rhombus 02/17

23 MODEL 112 Control Panel Single phase, simplex motor contactor control. The Model 112 control panel provides a reliable means of controlling one 120, 208, or 240 VAC single phase pump in pump chambers, sump pump basins, irrigation systems and lift stations. Two control switches activate a magnetic motor contactor to turn the pump on and off. If an alarm condition occurs, an additional alarm switch activates the audio/visual alarm system. Standard Control Panels PANEL COMPONENTS Model Shown 1121W114X 1. Enclosure measures X X cm (8 x 8 x 4 inches). Choice of NEMA 1 (steel for indoor use), or NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use) Note: Options selected may increase enclosure size and change component layout. 2. Magnetic Motor Contactor controls pump by switching electrical lines 3. HOA (Hand/Off/Automatic) Switch for manual pump control 4. Green Pump Run Indicator Light 5. Float Switch Terminal Block 6. Alarm and Control Fuses 7. Alarm and Control Power Indicators 8. Ground Lug 9. Circuit Breaker (optional) provides pump disconnect and branch circuit protection. STANDARD ALARM PACKAGE 10. Red Alarm Beacon 11. Alarm Horn - NEMA 1 style utilizes an internally mounted buzzer in lieu of horn. 12. Exterior Alarm Test/Normal/Silence Switch NOTE: other options available. SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 21

24 Standard Control Panels 112 MODEL 112 ALARM PACKAGE 0 = select options or no alarm package 1 = alarm package (includes test/normal/silence switch, fuse, red light, horn & float) ENCLOSURE RATING I = Indoor, NEMA 1 (metal) W = Weatherproof, NEMA 4X (engineered thermoplastic) STARTING DEVICE 1 = magnetic motor contactor 120/208/240V 9 = magnetic motor contactor 120V only PUMP FULL LOAD AMPS 0 = 0-7 FLA 1 = 7-15 FLA 2 = FLA 3 = FLA PUMP DISCONNECTS 0 = no pump disconnect 4 = circuit breaker 120V (select STARTING DEVICE option 9 above) 120/208/240V (select STARTING DEVICE option 1 above) FLOAT SWITCH APPLICATION H or L = pump down or pump up (select 17 option) X = no floats WITH alarm package WITHOUT alarm package OPTIONS Listed below H ENCLOSURE UPSIZE - If you selected 3 or more of the H options, or one HH option. CODE DESCRIPTION CODE DESCRIPTION 1A Red beacon only / no audio (must select 1E if floats included) 1C Horn only / no visual (must select 1E if floats included) 1E Alarm float 3A Alarm flasher H 3B Manual alarm reset HH 4A Low level cutout (select option 4D if floats included) HH 4B Red low-level indicator & alarm (must select 4A also) 4D Low-level float H 5A Thermal cutout/heat sensor auto reset (for pumps w/thermal switch leads) HH 5E Seal failure circuit & red indicator (2 wire) 6A Auxiliary alarm contact, form C H 8A Elapsed time meter H 8C Event (cycle) counter HH 9_A Pump overload specify amperage after number 9 followed by letter "A". Example: 912A = 12 amp pump. HH 0-25 FLA HH FLA 10E Lockable latch - NEMA 4X 10E Lockable latch - NEMA 1 H 10F Lightning arrestor (select pump circuit breaker) H 10K Anti-condensation heater 11C NEMA 1 alarm panel must select option 6A 11D NEMA 4X alarm panel must select option 6A 11C NEMA 1 alarm panel must select option 6A 11D NEMA 4X alarm panel must select option 6A HH 14B Main disconnect (rotary style, mounted through door, non-fused) HH 0-20 FLA HH FLA HH 15A Control / alarm circuit breaker 16A 10' cord in lieu of 20' 16B 15' cord in lieu of 20' 16C 30' cord in lieu of 20' 16D 40' cord in lieu of 20' 17A SJE SignalMaster / mounting strap l 17B SJE SignalMaster / externally weighted l 17C Sensor Float / internally weighted s 17D Sensor Float / externally weighted s 17E Sensor Float Mini / pipe clamp s 17F Sensor Float Mini / externally weighted s 17J Sensor Float / pipe clamp s 19T TOA (Test/Off/Automatic) switch and pump run light through door mounted 19U HOA (Hand/Off/Automatic) switch and pump run light through door mounted 19X Door mounted pump run indicator 21A SJE PumpMaster in lieu of on/off switches l 21B SJE PumpMaster Plus in lieu of on/off switches l 21C Super Single in lieu of on/off switches s 21D Double Float in lieu of on/off switches s l Mechanically-activated s Mercury-activated If additional features are required, call the factory for a quote on an Engineered Custom control panel. SAMPLE 22 MODEL Alarm Package Enclosure Rating Starting Device W H 8A 17A Pump Full Load Amps Pump Disconnect Float Switch Application Options: Elapsed Time Meter, SJE SignalMaster / pipe clamp A SJE-Rhombus 02/17

25 MODEL 122 Control Panel Single phase, duplex alternating pump control with override. The Model 122 control panel is designed to alternately control two 120, 208, or 240 VAC single phase pumps in water and sewage installations. The alternating action equalizes pump wear. In addition to the alternating pump control, this system provides override control should either pump fail. If an alarm condition occurs, an alarm switch activates the audio/visual alarm system. Common applications include pump chambers, sump pump basins, irrigation systems and lift stations. Standard Control Panels PANEL COMPONENTS Model Shown 1221W114X6A 1. Enclosure measures 25.4 X 25.4 X cm (10 X 10 X 6 inches). Choice of NEMA 1 (steel for indoor use), or NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use) Note: Options selected may increase enclosure size and change component layout. 2. Magnetic Motor Contactors control pumps by switching electrical lines 3. HOA (Hand/Off/Automatic) Switches for manual pump control 4. Control Circuit Board provides pump control and alternation 5. Green pump Run Indicator Lights 6. Circuit Breakers (optional) provide pump disconnect and branch circuit protection 7. Ground Lugs 8. Float Status Indicator Lights 9. Control and Alarm Power Indicator Lights 10. Auxiliary Alarm Contact, form C STANDARD ALARM PACKAGE 11. Red Alarm Beacon 12. Alarm Horn - NEMA 1 style utilizes an internally mounted buzzer in lieu of horn 13. Exterior Alarm Test/Normal/Silence Switch NOTE: other options available. SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 23

26 Standard Control Panels 122 MODEL 122 ALARM PACKAGE 0 = select options or no alarm package 1 = alarm package (includes test/normal/silence switch, fuse, red light, & horn) ENCLOSURE RATING I = Indoor, NEMA 1 (metal) W = Weatherproof, NEMA 4X (engineered thermoplastic) STARTING DEVICE 1 = magnetic motor contactor 120/208/240V 9 = magnetic motor contactor 120V only PUMP FULL LOAD AMPS 0 = 0-7 FLA 1 = 7-15 FLA 2 = FLA 3 = FLA PUMP DISCONNECTS 0 = no pump disconnect 4 = circuit breaker 120V (select STARTING DEVICE option 9 above) 120/208/240V (select STARTING DEVICE option 1 above) FLOAT SWITCH APPLICATION H or L = pump down or pump up (select 17 option) X = no floats OPTIONS Listed below H ENCLOSURE UPSIZE - If you selected 3 or more of the H options, or one HH option. 6A CODE DESCRIPTION CODE DESCRIPTION 1A Red beacon only / no audio (must select "0" for alarm package) 1C Horn only / no visual (must select "0" for alarm package) H HH 3A Alarm flasher H 3B Manual alarm reset H H 4A Low level cutout (select Option 4D if floats included) H 4B Red low-level indicator & alarm (must select Option 4A also) 4D Redundant off float switch H 5A Thermal cutout/heat sensor auto reset (for pumps w/thermal switch leads) H 5E Seal failure circuit & red indicator (2 wire) 6A Auxiliary alarm contact, form C (included as standard) H 8A Elapsed time meter H 8C Event (cycle) counter H 9_A Pump overload specify amperage after number 9 followed by letter "A" Example: 912A = 12 amp pump. H 0-25 FLA H FLA 10E Lockable latch - NEMA 4X 10E Lockable latch - NEMA 1 H 10F Lightning arrestor (select pump circuit breaker) HH 10K Anti-condensation heater 11C NEMA 1 alarm panel 11D NEMA 4X alarm panel 14B Main disconnect (rotary style, mounted through door, non-fused) (must select circuit breaker) 0-20 FLA (total of both pumps) FLA (total of both pumps) 16A 10' cord in lieu of 20' 16B 15' cord in lieu of 20' 16C 30' cord in lieu of 20' 16D 40' cord in lieu of 20' 17A SJE SignalMaster / pipe clamp l 17B SJE SignalMaster / externally weighted l 17C Sensor Float / internally weighted s 17D Sensor Float / externally weighted s 17E Sensor Float Mini / pipe clamp s 17F Sensor Float Mini / externally weighted s 17J Sensor Float / pipe clamp s 19B Lead lag selector switch 19F Fourth float to separate alarm function from lag 19T TOA (Test/Off/Automatic) switches and pump run lights through door mounted 19U HOA (Hand/Off/Automatic) switches and pump run lights through door mounted 19X Door mounted pump run indicator l Mechanically-activated Mercury-activated If additional features are required, call the factory for a quote on an Engineered Custom control panel. SAMPLE MODEL W H 6A 8AC 17A Alarm Package Enclosure Rating Starting Device Pump Full Load Amps Pump Disconnect Float Switch Application Options: Auxiliary alarm contact, form C, Elapsed time meter, event (cycle) counter, SJE SignalMaster / pipe clamp A SJE-Rhombus 02/17

27 MODEL 312 Control Panel Three phase, simplex motor contactor control. The Model 312 control panel provides industrial and commercial customers with a reliable means of controlling one 208, 240, or 480 VAC three phase pump in water and sewage installations. Two control switches activate an IEC motor contactor to turn the pump on and off. If an alarm condition occurs, an additional alarm switch activates the audio/visual alarm system. Common applications include pump chambers, irrigation systems, and lift stations. Standard Control Panels PANEL COMPONENTS Model Shown 3121W301X 1. Enclosure measures x x cm (12 x 10 x 6 inches) NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use) 2. IEC Motor Contactor controls pump by switching electrical lines 3. Multi-Tap Transformer (208/240/480 VAC primary) provides 120V control/alarm voltage 4. Motor Protective Switch provides adjustable overload, branch circuit protection and pump disconnect 5. HOA (Hand/Off/Automatic) Switch for manual pump control 6. Green Pump Run Indicator Light 7. Alarm Fuse 8. Control Fuse 9. Alarm and Control Power Indicators 10. Float Switch Terminal Block 11. Input Power Terminal Block 12. Ground Lugs STANDARD ALARM PACKAGE 13. Red Alarm Beacon 14. Alarm Horn 15. Exterior Alarm Test/Normal/Silence Switch NOTE: other options available. SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 25

28 312 W MODEL 312 ALARM PACKAGE 0 = select options or no alarm package 1 = alarm package (includes test/normal/silence switch, fuse, red light, horn, & float) ENCLOSURE RATING W = Weatherproof, NEMA 4X (engineered thermoplastic) Standard Control Panels PUMP FULL LOAD AMPS 001 = FLA 101 = FLA 201 = FLA 301 = FLA 401 = FLA 511 = FLA 611 = FLA 621 = FLA 701 = FLA FLOAT SWITCH APPLICATION H or L = pump down or pump up (select 17 option) X = no floats WITH alarm package WITHOUT alarm package OPTIONS Listed below CODE DESCRIPTION CODE DESCRIPTION 1A Red beacon only / no audio (must select 1E if floats included) 1C Horn only / no visual (must select 1E if floats included) 1E Alarm float 3A Alarm flasher 3B Manual alarm reset 4A Redundant off (select option 4D if floats included) 4B Red redundant off indicator & alarm activation (must select 4A also) 4D Redundant off float (must select 4A option) (select 17 option) 5A Thermal cutout/heat sensor auto reset (for pumps w/thermal switch leads) 5E Seal failure circuit & red indicator (2 wire) 6A Auxiliary alarm contact, form C 8A Elapsed time meter 8C Event (cycle) counter *10A Clear inner swing-out door w/dead front (lights and switches mounted on inner door) *Panels ordered with this option cannot be returned. 10E Lockable latch - NEMA 4X 10G Lightning arrestor 10K Anti-condensation heater 11C NEMA 1 alarm panel (must select option 6A) 11D NEMA 4X alarm panel (must select option 6A) 14B Main Disconnect (14X12 enclosure upgrade) (rotary style, mounted through door, non-fused) 16A 10' cord in lieu of 20' 16B 15' cord in lieu of 20' 16C 30' cord in lieu of 20' 16D 40' cord in lieu of 20' 17A SJE SignalMaster / mounting strap l 17B SJE SignalMaster / externally weighted l 17C Sensor Float / internally weighted s 17D Sensor Float / externally weighted s 17E Sensor Float Mini / pipe clamp s 17F Sensor Float Mini / externally weighted s 17J Sensor Float / pipe clamp s 19T TOA (Test/Off/Automatic) switch and pump run light through door mounted 19U HOA (Hand/Off/Automatic) switch and pump run light through door mounted 19X Door mounted pump run indicator 21A SJE PumpMaster in lieu of on/off switches l 21B SJE PumpMaster Plus in lieu of on/off switches l 21C Super Single in lieu of on/off switches s 21D Double Float in lieu of on/off switches s. l Mechanically-activated s Mercury-activated SAMPLE If additional features are required, call the factory for a quote on an Engineered Custom control panel. MODEL Alarm Package Enclosure Rating W 401 H 3A 8A 17A Pump Full Load Amps Float Switch Application Options: Flasher, Elapsed Time Meter, SJE SignalMaster / pipe clamp A SJE-Rhombus 02/17

29 Standard Control Panels MODEL 322 Control Panel Three phase, duplex alternating pump control with override. The Model 322 control panel is designed to alternately control two 208, 240, 480 VAC three phase pumps in industrial and commercial water and sewage systems. The alternating action equalizes pump wear. In addition to the alternating pump control, this system provides override control should either pump fail. If an alarm condition occurs, the alarm switch activates the audio/visual alarm system. Common applications include lift stations, pump chambers, and irrigation systems. PANEL COMPONENTS 1. Enclosure measures x x cm (14 x 12 x 6 inches) NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use) Note: Options selected may increase enclosure size and change component layout. 2. IEC Motor Contactors control pumps by switching electrical lines 3. Multi-Tap Transformer (208/240/480 VAC primary) provides 120V control/alarm voltage 4. Motor Protective Switches provide adjustable overload, branch circuit protection and pump disconnect 5. Alternating Circuit Board provides pump control and alternation (U.S. Patent # 5,909,532) 6. Green Pump Run Indicator Lights 7. Alarm/Control Fuse 8. Float Status Indicator Lights 9. Float Switch Terminal Block 10. Input Power Terminal Block 11. Ground Lugs 12. HOA (Hand/Off/Automatic) Switches for manual pump control. 13. Control ON/OFF Switch STANDARD ALARM PACKAGE 14. Red Alarm Beacon 15. Alarm Horn 16. Exterior Alarm Test/Normal/Silence Switch NOTE: other options available. SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING. Model Shown 3221W301X PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 27

30 322 W MODEL 322 ALARM PACKAGE 0 = select options or no alarm package 1 = alarm package (includes test/normal/silence switch, fuse, red light, & horn) ENCLOSURE RATING W = Weatherproof, NEMA 4X (engineered thermoplastic) Standard Control Panels PUMP FULL LOAD AMPS 001 = FLA 101 = FLA 201 = FLA 301 = FLA 401 = FLA 511 = FLA 611 = FLA 621 = FLA 701 = FLA FLOAT SWITCH APPLICATION H or L = pump down or pump up (select 17 option) X = no floats OPTIONS Listed below H ENCLOSURE UPSIZE - If you select 1 or more of the H options or one HH option. CODE DESCRIPTION CODE DESCRIPTION 1A Red beacon only / no audio 1C Horn only / no visual 3A Alarm flasher 3B Manual alarm reset H 4A Redundant off (select option 4D if floats included) 4B Red redundant off indicator & alarm (must select 4A also) 4D Redundant off float (must select 4A option) (select 17 option) H 5A Thermal cutout/heat sensor auto reset (for pumps w/thermal switch leads) H 5E Seal failure circuit & red indicator (2 wire) 6A Auxiliary alarm contact, form C 8A Elapsed time meter H 8C Event (cycle) counter *10A Clear inner swing-out door w/dead front (lights and switches mounted on inner door) *Panels ordered with this option cannot be returned. 10E Lockable latch 10G Lightning arrestor 10K Anti-condensation heater 11C NEMA 1 alarm panel (select option 6A) 11D NEMA 4X alarm panel (select option 6A) H14B Main disconnect (rotary style, mounted through door, non-fused) H 0-10 FLA (total of both pumps) H FLA (total of both pumps) H FLA (total of both pumps) 16A 10' cord in lieu of 20' 16B 15' cord in lieu of 20' 16C 30' cord in lieu of 20' 16D 40' cord in lieu of 20' 17A SJE SignalMaster / pipe clamp l 17B SJE SignalMaster / externally weighted l 17C Sensor Float / internally weighted s 17D Sensor Float / externally weighted s 17E Sensor Float Mini / pipe clamp s 17F Sensor Float Mini / externally weighted s 17J Sensor Float / pipe clamp s 19B Lead lag selector switch 19F Fourth float to separate alarm function from lag 19T TOA (Test/Off/Automatic) switches and pump run lights through door mounted 19U HOA (Hand/Off/Automatic) switches and pump run lights through door mounted 19X Door mounted pump run indicator. l Mechanically-activated s Mercury-activated If additional features are required, call the factory for a quote on an Engineered Custom control panel. SAMPLE MODEL Alarm Package Enclosure Rating Pump Full Load Amps W 401 H 8AC 17A Float Switch Application Options: Elapsed Time Meter, Event (cycle) Counter, SJE SignalMaster / pipe clamp A SJE-Rhombus 02/17

31 MODEL LA32 Control Panel Three phase, duplex alternating pump control with override. The Model LA32 control panel is designed to alternately control two 208/240/480 VAC three phase pumps in industrial and commercial water and sewage systems. The alternating action equalizes pump wear. In addition to the alternating pump control, this system provides override control should either pump fail. If an alarm condition occurs, the alarm switch activates the audio/visual alarm system. Common applications include lift stations, pump chambers, and irrigation systems Standard Control Panels PANEL COMPONENTS Model Shown LA321W40119BU 1. Enclosure measures x x cm (14 x 12 x 6 inches) NEMA 4X (ultraviolet stabilized thermoplastic with removable mounting feet for outdoor or indoor use) 2. IEC Motor Contactors control pumps by switching electrical lines 3. Multi-Tap Transformer 208/240/480 VAC primary incoming voltage 4. Motor Protective Switches provide adjustable overload, branch circuit protection, phase loss/imbalance protection and pump disconnect 5. Alarm Horn provides audible warning of alarm condition (83 to 85 decibel) 6. Alarm/Control Supplemental Fuse on the transformer 7. Float Status Indicator Lights mounted on controller 8. Low Voltage Float Switch Terminal Block mounted on controller PENDING 9. 22mm Pump Run Lights mounted on door and controller mm HOA (Hand/Off/Automatic) Switches mounted on door mm Alarm Light mounted on door mm Alarm Silence Button 13. Multi-Tap Transformer Wire (field installed for proper voltage) 14. Lag Pump on Delay Timer 15. Power On Light mounted on controller 16. Lead/Lag Selector Switch mounted on controller 17. Ground Lugs NOTE: Exterior door labels are in Spanish. Installation instructions and schematic are bilingual (English/Spanish). SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 29

32 LA32 W X 19BU MODEL LA32 ALARM PACKAGE 0 = select options or no alarm package 1 = alarm package (includes normal/silence switch, fuse, red light, & horn) ENCLOSURE RATING W = Weatherproof, NEMA 4X (engineered thermoplastic) Standard Control Panels PUMP FULL LOAD AMPS 001 = FLA 101 = FLA 201 = FLA 301 = FLA 401 = FLA 511 = FLA 611 = FLA 621 = FLA 701 = FLA 801 = FLA FLOAT SWITCH APPLICATION X = no floats OPTIONS Listed below CODE DESCRIPTION 10E Lockable latch 19B Lead lag selector switch (standard) 19U HOA (Hand/Off/Automatic) switches and pump run lights through door mounted (standard) 26E Phase monitor If additional features are required, call the factory for a quote on an Engineered Custom control panel. SAMPLE MODEL Alarm Package Enclosure Rating Pump Full Load Amps LA32 1 W 401 X 19BU Float Switch Application Options: Lead/lag selector switch; HOA switches and pump run lights through door mounted A SJE-Rhombus 02/17

33 MODEL 32XR Control Panel Industrial grade three phase, duplex alternating pump control with override. The Model 32XR control panel is designed to be rugged, simple and versatile. One panel handles three voltages and a wide range variety of pump motor amperage requirements by simply field installing overload modules - up to 32 amps each. The Model 32XR operates with a 4-20mA transmitter which can be configured for either 1 or 2 backup float switches. The Model 32XR features the LCX3, a simple to operate controller with intuitive menu and graphic display Enlarged for detail Standard Control Panels 10 7 PANEL COMPONENTS PN Model Shown 32XR1W00X4A5ADEM6A8AC10AEG 1. Enclosure measures 40.7 x 40.6 x 25.4 cm (18 x 16 x 10 inches) NEMA 4X padlockable fiberglass enclosure for indoor or outdoor use 2. Inner Deadfront Door to protect against high voltage components 3. Hand-Off-Auto selector switches for manual pump control 4. LCX3 Controller is 4-20mA transmitter-based for continuous level monitoring features: Multiple alternation modes Pump seal fail detection Pump overtemp detection Configurable display units (m, ft, in, etc.) Pump fail to start Adjustable high and low alarm Cycle counter/hour meters 5. LED Alarm Beacon provides 360 degree visual check of alarm condition 6. Lightning Arrestor provides surge suppression with immediate indication if replacement is required 7. IEC HR Rated Motor Starters perform contactor/circuit breaker function, up to 32 FLA (requires separate overload modules) and provides location for field wiring of incoming power and pumps 8. Class 10 Ambient Overload Modules (sold separately) provide overload-short circuit, phase failure-phase imbalance and ground fault protection (equipment protection only); accessible through inner door (two modules required, field installation required) 9. Multi-Tap Transformer 208, 240, or 460V three phase input 10. Auxiliary Alarm Contact SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 31

34 Industrial grade three phase, duplex alternating pump control with override. LEVEL TRANSMITTER SENSOR KITS MODEL 32XR Control Panel Standard Control Panels Includes: (1) Sub-X Transmitter ftwc measuring range (4-20mA) 50 ft. vented cable (1) SJE MilliAmpMaster PLUS wide-angle control switch, 50 ft. (1) Float bracket Includes: (1) Sub-X Transmitter ftwc measuring range (4-20mA 0 ft. vented cable (2) SJE MilliAmpMaster PLUS wide-angle control switches, 50 ft. (1) Float bracket Includes: (1) LevelRat Transmitter 0-15 ftwc measuring range (4-20mA 0 ft. vented cable (2) SJE MilliAmpMaster PLUS wide-angle control switches, 50 ft. (1) Float bracket ORDERING INFORMATION MODEL 32XR CONTROL PANEL AND ACCESSORIES Part Number Description SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING. Shipping Weight XR1W004A5ADEM6A8A10AEG kg Overload Module, 3-12 FLA 0.23 kg Overload Module, 8-32 FLA 0.23 kg Sub-X Transmitter Kit, (1) 50 ft. MAP Float, with bracket 5.44 kg Sub-X Transmitter Kit, (2) 50 ft. MAP Floats, with bracket 7.71 kg LevelRat Transmitter Kit, (2) 50 ft. MAP Floats, with bracket 6.35 kg 32 customer.service@sjerhombus.com A SJE-Rhombus 02/17

35 SJE EMD Series CE Rated Control Panels Single-phase or three-phase, CE rated pump control panels. SJE EMD series are CE Rated electromechanical control panels designed to control one or two submersible singlephase or three-phase electric pumps in water and wastewater applications. They are provided with a thermal overload protection relay incorporated in the IP55 weather-proof cabinet. The control panels operate the pumps based on the liquid level from signals provided from float or pressure switches. Standard Control Panels APPLICATIONS Water supply pumps Wastewater pumps Many more motor control applications EMD SERIES Models EMD1S / EMD1T EMD1S is an electromechanical control panel for one single-phase pump with thermal overload protection. Plastic enclosure 400mm (H) x 300mm (W) x 180mm (D) 8 kg EMD1T is an electromechanical control panel for one three-phase pump with thermal overload protection. Plastic enclosure 400mm (H) x 300mm (W) x 180mm (D) 8 kg Models EMD2S / EMD2T EMD2S is an electromechanical control panel for two single-phase pumps with thermal overload protection. Metal enclosure - RAL mm (H) x 400mm (W) x 250mm (D) 18 kg EMD2T is an electromechanical control panel for two three-phase pumps with thermal overload protection. Metal enclosure - RAL mm (H) x 400mm (W) x 250mm (D) 18 kg PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 33

36 SJE EMD Series CE Rated Control Panels Single-phase or three-phase, CE rated pump control panels. NOTE SJE EMD Series CE rated control panels are manufactured at SJE-Rhombus Suzhou Co. Ltd. Contact SJE-Rhombus for pricing or submit an online quote request at Standard Control Panels FEATURES Input Power: 1~ 50/60 Hz, 230V ±10% 3~ 50/60 Hz, 400V ±10% Power: 0.25~4Kw (single phase) 0.25~37Kw (three phase) Direct On Line (DOL) motor starters 230V/24V, 400V/24V transformer for control circuit Low voltage inputs for float or pressure switches Hand-Off-Auto selector switches for each pump Main power disconnect switch with door interlock handle LED indicator lights for Power ON, Pump Running, and Pump Tripped High level alarm buzzer Alarm silence push button Protection class: IP55 Operating temperature: -5ºC to +40ºC Storage temperature: -20ºC to +60ºC Relative humidity: 50% at 40ºC, non-condensing Automatic pump alternation (dual pump) Thermal overload relay with phase loss sensitivity Motor short-circuit and over-current Control transformer with fusing CE certified - no agency approvals for use in the United States or Canada. OPTIONS Emergency stop button Power failure alarm Horn and beacon, 24 VDC (two auxiliary relays) for level alarm Phase loss, phase reversal, over-voltage, under-voltage protection Hour meter for each pump Cycle counter for each pump Voltmeter / Ammeter Panel anti-condensation heater Additional options available upon request 34 customer.service@sjerhombus.com A SJE-Rhombus 02/17

37 Designed to control one 120V single phase pump using a receptacle for easy pump connections in indoor simplex pump applications. No wiring needed. The SJE Oil Spotter system is designed to provide pump control and alarm notification of potentially threatening water and oil levels in simplex pumping applications. The system features an innovative, factory-installed Oil Water Switch that senses the difference between oil and water to remove water from the tank, while preventing oil from entering the environment. The Oil Water Switch features four probes (start level, stop level, high water level, reference for ground) and a mechanical high oil alarm float. SJE OIL SPOTTER System Common applications include elevator sump basins, transformer vaults, leachate well applications, garages or any application requiring ASME A17.1 compliance. In normal operation, as water and oil enter the tank, the oil rises to create a floating layer on top of the water. The water level rises to reach the Start Probe, activating the pump to remove water from the tank. It continues pumping water out of the tank until the water level falls below the Stop Probe (5" pumping range). If the water level continues to rise and reaches the High Water Probe, the red high water LED indicator illuminates and auxiliary contacts close (activating an optional Tank Alert alarm or other remote device). If the oil level rises to activate the mechanical High Oil Float, the red high oil LED indicator illuminates and auxiliary contacts close (activating an optional Tank Alert alarm or other remote device). FEATURES NEMA 1 enclosure rated for indoor use Factory-installed 3 meters (10 feet) power cord LED indicators for: High Water (red) High Oil (red) Pump Run (green) Power (green) Factory installed Oil Water switch includes: High Oil Float High Water Probe Start Probe Stop Probe Reference Probe SPECIFICATIONS Voltage: 120 VAC Enclosure: x x cm (8 x 8 x 4 inches), NEMA 1 indoor Receptacle: 120 VAC NEMA type 5-15 Maximum Current: 15 amps Standard Control Panels SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 35

38 SJE OIL SPOTTER System Designed to control one 120V single phase pump using a receptacle for easy pump connections in indoor simplex pump applications. No wiring needed. ORDERING INFORMATION Part # Description Ship Weight SJE Oil Spotter System 5.89 kg SJE Oil Spotter System with Tank Alert AB 6.80 kg SEE INTERNATIONAL PRICEBOOK FOR LIST PRICING. Standard Control Panels SPECIFICATIONS Voltage: 120 VAC Enclosure: x x cm (8 x 8 x 4 inches), NEMA 1 indoor Receptacle: 120 VAC NEMA type 5-15 Maximum Current: 15 amps customer.service@sjerhombus.com A SJE-Rhombus 02/17

39 TANK ALERT AB Alarm System Easy-to-install liquid level alarm system with auto-reset and battery backup features for indoor use. This alarm system monitors liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural, and other water applications. The Tank Alert AB alarm system can serve as a high or low level alarm depending on the float switch model used. The alarm horn sounds when a potentially threatening liquid level condition occurs. The horn can be silenced, but the alarm light remains on until the condition is remedied. Once the condition is cleared, the alarm will automatically reset. A green "Power On" light indicates 120 VAC primary power to the alarm. Low battery chirp feature indicates when battery should be replaced. FEATURES NEMA 1 enclosure, designed for ease of installation, rated for indoor use. Automatic alarm reset. Red "alarm" light and green "power on" light, alarm "test" switch, and horn "silence" switch. Alarm horn sounds at 87 decibels at 3 meters (10 feet). Can be used with any UL Listed / Recognized switching mechanism rated to include 1 amp, 9 VDC load. If primary power fails, the alarm system continues to work due to battery backup feature (battery not included). Complete package includes standard SJE SignalMaster control switch with 4.57 meters (15 feet) of cable (other lengths available) and mounting clamp. Switching mechanism operates on low voltage and is isolated from the power line to reduce the possibility of shock. Low battery chirp. Easy access battery compartment. External terminal block for easy float switch installation. OPTIONS When ordered with the alarm, this system is available with: Alternate float switch models for high or low level warning. Auxiliary dry normally open and normally closed contacts. (Tank Alert AB auxiliary contacts included is CSA certified only.) Splice kit. SPECIFICATIONS Voltage: Primary: 120 VAC, 60 Hz, 2.4 watts max. (alarm condition) Secondary: 9 VDC Battery Backup Power: 9 VDC Alarm Enclosure: x x 5.71 cm (6 x 4 x 2.25 inch), NEMA 1 plastic Alarm Horn: 87 decibels at 3 meters (10 feet) Auxiliary Alarm Contacts (optional): (CSA certified only unit) Voltage: 120 VAC Current: 5 amps maximum N/O 3 amps maximum N/C Power Cord: 1.8 meter (6 foot) Float Switch Connection Terminal: For float switch connection only. Do not apply power. (Voltage across terminals is 8-9 VDC). Float Switch: SJE SignalMaster control switch with mounting clamp Cable: 4.57 meters (15 feet), flexible 18 gauge, 2 conductor (UL) SJOW, water-resistant (CPE) Float: 7.0 cm diameter x 12.3 cm long (2.74 inch x 4.83 inch), high impact, corrosion resistant polypropylene housing for use in sewage and water up to 60 o C (140 o F) SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 37 Alarm Systems

40 TANK ALERT AB Alarm System Easy-to-install liquid level alarm system with auto-reset and battery backup features for indoor use. ORDERING INFORMATION STANDARD ALARM (120 VAC) Part # Description Shipping Weight TA AB-01H (120 VAC w/15' SJE SignalMaster High Level) 1.24 kg TA AB-01L (120 VAC w/15' SJE SignalMaster Low Level) 1.24 kg TA AB-01X (120 VAC no float) 0.65 kg H = High Level L = Low Level X = No Float MASTER CARTON holds 16 boxed units. SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING. Option AUX Description Auxiliary Alarm Contacts (CSA certified only unit, factory installed) OPTIONS Control Switch Options: The Tank Alert AB alarm system comes standard with a 4.57 meter (15 ft.) SJE SignalMaster control switch with mounting clamp. Other float switches are available. See the control switch section of this catalog. Alarm Systems customer.service@sjerhombus.com A SJE-Rhombus 02/17

41 TANK ALERT EZ Alarm System Innovative, indoor or outdoor liquid level alarm system. This alarm system monitors liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural, and other water applications. The Tank Alert EZ indoor/outdoor alarm can serve as a high or low level alarm depending on the float switch model used. This easy to install alarm features an innovative, 2-color molded enclosure. The top half of the enclosure is translucent and illuminates red when an alarm condition occurs. FEATURES U.S. Patent Nos. 8,737,672 and D695,640 2-color molded enclosure offers a distinct look; upper translucent half illuminates in alarm condition. Removable lower cover provides greater access for easier field wiring while the internal circuitry remains protected. Interlocking enclosure features unique sound chamber to amplify the horn, while helping prevent moisture from entering. External mounting tabs for easy installation. Enclosure meets Type 3R water-tight standards. Enclosure has indicator marks on bottom for easy placement of cord entry locations. Automatic alarm reset, horn silence switch, and alarm test switch. Alarm horn sounds at 82 decibels at 3 meters (10 feet). Alarm system (when installed on separate circuit) operates even if pump circuit fails. Green power on indicator. Includes auxiliary alarm contacts for easy attachment of remote devices. Complete package includes standard SJE SignalMaster control switch with 4.57 meters (15 feet) of cable (other lengths available) and mounting clamp. SPECIFICATIONS Voltage: 120 VAC Model: Primary: 120 VAC, 50/60 Hz, 3.8 watts max. (alarm condition) Secondary: 9 VDC 240 VAC Model: Primary: 240 VAC, 50/60 Hz, 3.8 watts max. (alarm condition) Secondary: 9 VDC Alarm Enclosure: x x 6.35 cm (6.7 x 5.3 x 2.5 inch), indoor-outdoor, weatherproof, thermoplastic meets Type 3R water-tight standard Alarm Horn: 82 decibels at 3 meters (10 feet) Auxiliary Alarm Contacts: 240 VAC / 30 VDC, 1.5 amps max., 50/60 Hz (circuit not supervised) Pre-mounted Terminal Block (optional): rated for 20 amps, 120/240 VAC Power Cord (optional - 120V Model only): 1.8 meter (6 foot) cord with 120 VAC North American plug Float Switch: SJE SignalMaster control switch with mounting clamp Cable: 4.57 meters (15 feet), flexible 18 gauge, 2 conductor (UL) SJOW, water-resistant (CPE) Float: 7 cm diameter x 12.3 cm long (2.74 x 4.83), high impact, corrosion resistant polypropylene housing for use in sewage and non-potable water up to 140 o F (60 o C) Maximum Water Depth: 9 meters (30 feet), 13 PSI Electrical: 5 amps, 125 VAC/250 VAC, 50/60 Hz Alarm Systems SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 39

42 ORDERING INFORMATION TANK ALERT EZ Alarm System Innovative, indoor or outdoor liquid level alarm system. STANDARD ALARM (240 VAC) Shipping Part # Description Weight TAEZ-02H (240 VAC w/sje SignalMaster High Level) 1.25 kg TAEZ-02X (240 VAC no float) 0.68 kg STANDARD ALARM (240 VAC) with terminal block Shipping Part # Description Weight TAEZ-02HTB (240 VAC w/sje SignalMaster High Level TB) 1.25 kg TAEZ-02XTB (240 VAC no float w/terminal Block) 0.68 kg STANDARD ALARM (120 VAC) Shipping Part # Description Weight TAEZ-01H (120 VAC w/sje SignalMaster High Level) 1.25 kg TAEZ-01X (120 VAC no float) 0.68 kg STANDARD ALARM (120 VAC) with terminal block Shipping Part # Description Weight TAEZ-01HTB (120 VAC w/sje SignalMaster High Level TB) 1.25 kg TAEZ-01XTB (120 VAC no float w/terminal Block) 0.68 kg Alarm Systems Option Description PC 1.83 meter (6 ft) power cord with two RCC8 1.27cm (1/2 inch) liquid-tight connectors (120V model only) H = High Level L = Low Level X = No Float TB = Includes Terminal Block MASTER CARTON holds 12 boxed units. SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING. OPTIONS Control Switch Options: The Tank Alert EZ alarm system comes standard with a 4.57 meter (15 ft.) SJE SignalMaster control switch with mounting clamp. Other float switches are available. See the control switch section of this catalog customer.service@sjerhombus.com A SJE-Rhombus 02/17

43 TANK ALERT EZ ( ) Alarm System Innovative, indoor or outdoor liquid level alarm system. This alarm system monitors liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural, and other water applications. The Tank Alert EZ (CE) indoor/outdoor alarm can serve as a high or low level alarm depending on the float switch model used. This easy to install alarm features an innovative, 2-color molded enclosure. The top half of the enclosure is translucent and illuminates red when an alarm condition occurs. FEATURES U.S. Patent Nos. 8,737,672 and D695,640 2-color molded enclosure offers a distinct look; upper translucent half illuminates in alarm condition. Removable lower cover provides greater access for easier field wiring while the internal circuitry remains protected. Interlocking enclosure features unique sound chamber to amplify the horn, while helping prevent moisture from entering. External mounting tabs for easy installation. Enclosure meets Type 3R water-tight standards. Enclosure has indicator marks on bottom for easy placement of cord entry locations. Automatic alarm reset, horn silence switch, and alarm test switch. Alarm horn sounds at 82 decibels at 3 meters (10 feet). Alarm system (when installed on separate circuit) operates even if pump circuit fails. Green power on indicator. Includes auxiliary alarm contacts for easy attachment of remote devices. Complete package includes standard SJE SignalMaster control switch with 4.57 meters (15 feet) of cable (other lengths available) and mounting clamp. SPECIFICATIONS Voltage: 240 VAC Model: Primary: 240 VAC, 50/60 Hz, 3.8 watts max. (alarm condition) Secondary: 9 VDC Alarm Enclosure: x x 6.35 cm (6.7 x 5.3 x 2.5 inch), indoor-outdoor, weatherproof, thermoplastic meets Type 3R water-tight standard Alarm Horn: 82 decibels at 3 meters (10 feet) Auxiliary Alarm Contacts: 240 VAC / 30 VDC, 1.5 amps max., 50/60 Hz (circuit not supervised) Float Switch: SJE SignalMaster control switch with mounting clamp Cable: 4.57 meters (15 feet), flexible 18 gauge, 2 conductor (UL) SJOW, water-resistant (CPE) Float: 7 cm diameter x 12.3 cm long (2.74 x 4.83), high impact, corrosion resistant polypropylene housing for use in sewage and non-potable water up to 60 o C (140 o F) Maximum Water Depth: 9 meters (30 feet), 13 PSI Electrical: 5 amps, 240 VAC, 50/60 Hz Alarm Systems SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 41

44 TANK ALERT EZ ( ) Alarm System Innovative, indoor or outdoor liquid level alarm system. NOTE The Tank Alert EZ (CE) alarms are manufactured at SJE-Rhombus Suzhou Co. Ltd. Contact SJE-Rhombus for pricing or submit an online quote request at ORDERING INFORMATION STANDARD ALARM (240 VAC) Part # Description Shipping Weight TAEZCE-02H (240 VAC w/sje SignalMaster High Level) 1.25 kg TAEZCE-02X (240 VAC no float) 0.68 kg H = High Level L = Low Level X = No Float MASTER CARTON holds 12 boxed units. CONTACT CORPORATE FACTORY FOR PRICING. OPTIONS Control Switch Options: The Tank Alert EZ alarm system comes standard with a 4.57 meter (15 ft.) SJE SignalMaster control switch with mounting clamp. Other float switches are available. See the control switch section of this catalog. Alarm Systems 42 customer.service@sjerhombus.com A SJE-Rhombus 02/17

45 TANK ALERT XT Indoor/Outdoor Alarm (240 VAC) Versatile, indoor or outdoor liquid level alarm system. This alarm system monitors liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural, and other water applications. The Tank Alert XT indoor/outdoor alarm can serve as a high or low level alarm depending on the float switch model used. The alarm horn sounds and the red beacon illuminates when a potentially threatening liquid level condition occurs. The horn can be silenced but the alarm light remains on until the condition is remedied. A power on light on the switch indicates power to the alarm panel. FEATURES Enclosure meets Type 3R water-tight standard. Automatic alarm reset, horn silence switch, and alarm test switch. Alarm horn sounds at 82 decibels at 3 meters (10 feet). Alarm system (when installed on separate circuit) operates even if pump circuit fails. Complete package includes standard SJE SignalMaster control switch with 4.57 meters (15 feet) of cable (other lengths available) and mounting clamp. OPTIONS When ordered with the alarm, this system is available with: Alternate float switch models for high or low level warning. Auxiliary dry normally open contacts for easy attachment of remote devices. Pre-mounted terminal block so enclosure can also be used as a junction box for splicing pump, pump switch, and pump power. Meets NEC standard for junction boxes. SPECIFICATIONS Voltage: VAC, 50/60 Hz Alarm Enclosure: X X 7.62 cm (6.5 X 4.5 x 3.0 inches), indoor-outdoor, weatherproof, thermoplastic Alarm Horn: 82 decibels at 3 meters (10 feet) Auxiliary Alarm Contacts (optional): rated for 240 VAC, 50/60 Hz, 5 amps Terminal Block (optional): rated for 240 VAC, 20 amps Float Switch: SJE SignalMaster control switch with mounting clamp Cable: 4.57 meters (15 feet), flexible 18 gauge, 2 conductor (UL) SJOW, water-resistant (CPE) Float: 7.0 cm diameter x 12.3 cm long (2.74 inches diameter x 4.83 inches long), high impact, corrosion resistant polypropylene housing for use in sewage and water up to 60 o C (140 o F). Switch: 125/250 VAC, 50/60 Hz, 5 amps Alarm Systems SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 43

46 TANK ALERT XT Indoor/Outdoor Alarm (240 VAC) ORDERING INFORMATION Versatile, indoor or outdoor liquid level alarm system. STANDARD ALARM Shipping Part # Description Weight TAXT-02H (240 VAC w/sje SignalMaster High Level) 1.36 kg TAXT-02L (240 VAC w/sje SignalMaster Low Level) 1.36 kg TAXT-02X (240 VAC no float) 0.68 kg STANDARD ALARM with terminal block Part # Description Shipping Weight TAXT-02HTB (240 VAC w/sje SignalMaster High Level TB) 1.59 kg TAXT-02LTB (240 VAC w/sje SignalMaster Low Level TB) 1.59 kg TAXT-02XTB (240 VAC no float w/terminal Block) 0.90 kg H = High Level L = Low Level X = No Float TB = Includes Terminal Block MASTER CARTON holds 12 boxed units. SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING. Option A Auxiliary contacts (factory installed) Description Alarm Systems OPTIONS Control Switch Options: The Tank Alert XT 240V alarm system comes standard with a 4.57 meter (15 ft.) SJE SignalMaster control switch with mounting clamp. Other float switches are available. See the control switch section of this catalog customer.service@sjerhombus.com A SJE-Rhombus 02/17

47 TANK ALERT XT Indoor/Outdoor Alarm (120 VAC) Versatile, indoor or outdoor liquid level alarm system. This alarm system monitors liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural, and other water applications. The Tank Alert XT indoor/outdoor alarm can serve as a high or low level alarm depending on the float switch model used. The alarm horn sounds and the red beacon illuminates when a potentially threatening liquid level condition occurs. The horn can be silenced but the alarm light remains on until the condition is remedied. A power on light on the switch indicates power to the alarm panel. FEATURES Enclosure meets Type 3R water-tight standard. Automatic alarm reset, horn silence switch, and alarm test switch. Alarm horn sounds at 85 decibels at 3 meters (10 feet). Alarm system (when installed on separate circuit) operates even if pump circuit fails. Complete package includes standard SJE SignalMaster control switch with 4.57 meters (15 feet) of cable (other lengths available) and mounting clamp. OPTIONS When ordered with the alarm, this system is available with: Alternate float switch models for high or low level warning. Auxiliary dry normally open contacts for easy attachment of remote devices. Pre-mounted terminal block so enclosure can also be used as a junction box for splicing pump, pump switch, and pump power. Meets NEC standard for junction boxes. 1.8 meter (6 feet) power cord and liquid-tight connectors. SPECIFICATIONS Voltage: 120 VAC, 50/60 Hz, 7 watts max. (alarm condition) Alarm Enclosure: X X 7.62 cm (6.5 X 4.5 x 3.0 inches), indoor-outdoor, weatherproof, thermoplastic meets Type 3R water-tight standard Alarm Horn: 85 decibels at 3 meters (10 feet), meets Type 3R water-tight standard as installed by factory Alarm Beacon: meets Type 3R water-tight standard as installed by factory Test/Silence Switch: certified to IP66 and IP68 standards Auxiliary Alarm Contacts (optional): rated for 120 VAC, 50/60 Hz, 5 amps Pre-mounted Terminal Block (optional): rated for 120/230 VAC, 20 amps Power Cord (optional): 1.8 meters (6 feet) cord with 120 VAC plug Float Switch: SJE SignalMaster control switch with mounting clamp Cable: 4.57 meters (15 feet), flexible 18 gauge, 2 conductor (UL) SJOW, water-resistant (CPE) Float: 7.0 cm diameter x 12.3 cm long (2.74 inches diameter x 4.83 inches long), high impact, corrosion resistant polypropylene housing for use in sewage and water up to 60 o C (140 o F) Switch: 125/250 VAC, 50/60 Hz, 5 amps Alarm Systems SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 45

48 TANK ALERT XT Indoor/Outdoor Alarm (120 VAC) ORDERING INFORMATION Versatile, indoor or outdoor liquid level alarm system. STANDARD ALARM Shipping Part # Description Weight TAXT-01H (120 VAC w/sje SignalMaster High Level) 1.36 kg TAXT-01L (120 VAC w/sje SignalMaster Low Level) 1.36 kg TAXT-01X (120 VAC no float) 0.68 kg STANDARD ALARM with terminal block Part # Description Shipping Weight TAXT-01HTB (120 VAC w/sje SignalMaster High Level TB) 1.59 kg TAXT-01XTB (120 VAC no float w/terminal Block) 0.90 kg H = High Level L = Low Level X = No Float TB = Includes Terminal Block PC = Includes Power Cord MASTER CARTON holds 12 boxed units. SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING. Option A PC Description Auxiliary contacts (factory installed) 1.8 meter (6 feet) power cord (installed) with 2 RCC8 1/2 inch liquid-tight connectors Alarm Systems OPTIONS Control Switch Options: The Tank Alert XT 120V alarm system comes standard with a 4.57 meter (15 ft.) SJE SignalMaster control switch with mounting clamp. Other float switches are available. See the control switch section of this catalog customer.service@sjerhombus.com A SJE-Rhombus 02/17

49 SJE LEVEL MONITOR CL System Monitors tank levels by utilizing the C-Level floatless sensor. The SJE Level Monitor CL system is a convenient way to monitor tank levels by utilizing a scalable LED bargraph to represent the level as a percentage of a full tank. The adjustable alarm is easy to set using the Alarm Level and Set buttons on the touch pad. As the liquid level reaches the installer-specified alarm set point, the audible alarm is activated. The audible alarm can be silenced using the Test/Silence button, but the alarm light will remain on until the condition is remedied. FEATURES C-Level Sensor US Patent 8,336,385. Other patents pending. NEMA 1 rated for indoor use. Power on and alarm indicators. Adjustable alarm set point. Can be calibrated for tanks ranging: cm to cm (12 inches to 40 inches) for 40 inch C-Level CL cm to 254 cm (25 inches to 100 inches) for 100 inch C-Level CL100 Utilizes the innovative, floatless C-Level Sensor. Various cable lengths available to allow monitoring tanks up to 91.4 meters (300 feet) away. 10 segment LED bargraph displays the tank level. Test/Silence button Alarm Level button Set button Auxiliary contacts (normally open and normally closed) for Class II circuits. Can be configured as high level, low level or no alarm. OPTIONS This system is available with: C-Level CL40 sensor with 1.22 meters (4 feet) vent tube and 6.09 meters (20 feet) cable C-Level CL40 sensor with 1.22 meters (4 feet) vent tube and meters (40 feet) cable C-Level CL40 sensor with 1.22 meters (4 feet) vent tube and meters (80 feet) cable C-Level CL40 sensor with 1.22 meters (4 feet) vent tube and meters (200 feet) cable C-Level CL100 sensor with 3.05 meters (10 feet) vent tube and 6.09 meters (20 feet) cable C-Level CL100 sensor with 3.05 meters (10 feet) vent tube and meters (40 feet) cable C-Level CL100 sensor with 3.05 meters (10 feet) vent tube and meters (80 feet) cable C-Level CL100 sensor with 3.05 meters (10 feet) vent tube and meters (200 feet) cable Other C-Level sensor lengths available upon request SPECIFICATIONS Voltage: 120 VAC, 50/60 Hz, 0.15A Class II transformer (USA style plug. Contact factory for country specific transformers.) Output Contact Rating: 3 amp, Class II circuits Enclosure: 7.62 cm x cm x 3.81 cm (3 inches x 4.25 inches x 1.25 inches), NEMA 1 thermoplastic Vent C-Level Sensor Alarm Systems SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 47

50 Alarm Systems ORDERING INFORMATION Part Number SJE LEVEL MONITOR CL System Monitors tank levels by utilizing the C-Level floatless sensor. Description SJE Level Monitor CL w/c-level CL40 sensor SJE Level Monitor CL w/c-level CL40 sensor SJE Level Monitor CL w/c-level CL40 sensor SJE Level Monitor CL w/c-level CL40 sensor SJE Level Monitor CL w/c-level CL100 sensor SJE Level Monitor CL w/c-level CL100 sensor SJE Level Monitor CL w/c-level CL100 sensor SJE Level Monitor CL w/c-level CL100 sensor SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING. WIRING Vent Tube Length 1.22 meters (4 feet) 1.22 meters (4 feet) 1.22 meters (4 feet) 1.22 meters (4 feet) 3.05 meters (10 feet) 3.05 meters (10 feet) 3.05 meters (10 feet) 3.05 meters (10 feet) Cable Length 6 meters (20 feet) meters (40 feet) meters (80 feet) meters (200 feet) 6 meters (20 feet) meters (40 feet) meters (80 feet) meters (200 feet) Ship Weight 1.41 kg 1.68 kg 2.27 kg 3.18 kg 1.62 kg 1.90 kg 2.49 kg 3.40 kg 48 customer.service@sjerhombus.com A SJE-Rhombus 02/17

51 Pump Floats SJE QUEST Pump Float - Latin American Package Mechanically-activated, wide-angle pump switches designed for performance and dependability. These mechanically-activated, wide-angle pump switches provide automatic control of pumps, alarms, and panels in wastewater and non-potable water applications. This SJE Quest float is packaged in a bilingual bag (English and Spanish) designed to easily display for retail customers in Latin America. GENERAL SPECIFICATIONS 125/250 VAC, 50/60 Hz, 4 Amp inductive load Mechanically-activated, snap action contacts (non-mercury) H05 RNF 0.75 mm 2 3-conductor cable Direct control of pumps up to 3/4 HP at 250 VAC SPDT (3-wire, normally open or normally closed) Switch Dimensions: 7.7 cm x 13 cm x 4 cm (3 inch x 5 inch x 1.6 inch) Non-toxic, corrosion resistant polypropylene switch housing Temperature rating up to 50º C (122º F) Maximum water depth of 10 meters (30 feet) IPX8 enclosure rating Adjustable pumping range of 23 to 91 cm (9 to 36 inches) Patented sealing design provides excellent protection from moisture centering the float housing CE certified, TUV certified Includes one-piece cable weight for mounting Note: These switches are not recommended for controlling electrical loads less than 100 ma, 12 VAC. Must be used with pumps that provide integral thermal overload protection. Not available for sale in Canada or USA. *SJE Quest is a registered trademark of SJE-Rhombus in Asia and the EU. SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 49

52 Pump Floats SJE QUEST Pump Float - Latin American Package Mechanically-activated, wide-angle pump switches designed for performance and dependability. NOTE SJE Quest pump switches are manufactured at SJE-Rhombus Suzhou Co. Ltd. but inventoried and sold through SJE-Rhombus Detroit Lakes, Minnesota, USA. ORDERING INFORMATION (MUST BE ORDERED BY CASE QUANTITIES ONLY) SJE QUEST Pump Float - Latin American Package PART NUMBER CASE QUANTITY Cable Length DESCRIPTION Model SHIPPING WEIGHT CASE QUANTITY Meters Quest SPDT 17.0 kg Meters Quest SPDT 20.0 kg Meters Quest SPDT 18.6 kg SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING customer.service@sjerhombus.com A SJE-Rhombus 02/17

53 SJE QUEST and SJE QUEST II Pump Floats Mechanically-activated, wide-angle pump switches designed for performance and dependability. These mechanically-activated, wide-angle pump switches provide automatic control of pumps, alarms, and panels in wastewater and non-potable water applications. Includes innovative one-piece cable weight for mounting. GENERAL SPECIFICATIONS Multiple cable options - see backside for details Mechanically activate, snap action contacts Multiple microswitch options available - see backside for details Non-toxic, corrosion resistant polypropylene switch housing Temperature rating up to 50º C (122º F) Maximum water depth of 10 meters (30 feet) IPX8 enclosure rating Adjustable pumping range of 23 to 91 cm (9 to 36 inches) CE certified, TUV certified - no agency approvals for use in the United States or Canada Available with or without cable weight Multiple color options available Note: These switches are not recommended for controlling electrial loads less than 100 ma, 12 VAC. Must be used with pumps that provide integral thermal overload protection. MODEL SPECIFIC SPECIFICATIONS SJE QUEST pump float Switch Dimensions: 7.7 cm x 13 cm x 4 cm (3 inch x 5 inch x 1.6 inch Patented sealing design provides excellent protection from moisture centering the float housing. SJE QUEST II pump float Float Dimensions: 7 cm diameter x 12.3 cm length (2.74 inch diameter x 4.83 inch length) Pump Floats *SJE Quest is a registered trademark of SJE-Rhombus in Asia and the EU. SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 51

54 SJE QUEST and SJE QUEST II Pump Floats Mechanically-activated, wide-angle pump switches designed for performance and dependability. NOTE SJE Quest and SJE Quest II pump switches are manufactured at SJE-Rhombus Suzhou Co. Ltd. Contact SJE-Rhombus for pricing or submit an online quote request at CONFIGURATION OPTIONS These switches are available in the following configurations: 3-wire SPDT version, normally open for pump down and normally closed for pump up (Function, Class II). 3-wire version with ground plate, normally open for pump down (Function, Class I); normally closed for pump up version available upon request. 2 wire version without ground plate, normally open for pump down (Function Class II); normally closed for pump up version available upon request. Standard H07 rubber cable lengths of 3, 5, or 10 meters (10, 15, or 30 feet); H05 PVC cable versions available upon request. CABLE OPTIONS These switches are available with the following cable options: H07 RNF 1mm 2 (2 or 3 conductor) H05 RNF 0.75 mm 2 (2 or 3 conductor) ELECTRICAL OPTIONS Pump Floats Single Phase 50/60 Hz 125 / 250 VAC Max Inductive Running Amps Cable Type 10 Amp H07 8 Amp H07 4 Amp H VAC 6 Amp H07 PACKAGING OPTIONS These switches are available with the following packaging options: Bulk Individually bagged Customized packaging 52 customer.service@sjerhombus.com A SJE-Rhombus 02/17

55 SJE MICROMASTER, SJE MICROMASTER PLUS, SJE MICROMASTER SPDT Pump Floats Mechanically-activated, wide-angle switch designed for performance and dependability. These mechanically-activated, wide-angle switches provide automatic control of pumps in: Water Sewage applications These pump switches are not sensitive to rotation or turbulence allowing them to be used in both calm and turbulent applications. GENERAL SPECIFICATIONS Flexible SJOW, water-resistant (CPE) cable High impact, corrosion resistant, polypropylene float housing Temperature rating up to 60º C (140º F) Maximum water depth of 9 meters (30 feet) or 90 kpa (13 psi) IPX8 enclosure rating Float dimensions: 7.0 cm diameter x 12.3 cm long (2.74 inch x 4.83 inch) Suitable for Catagory II installations Protected by double insulation Adjustable pumping range of 20 to 91 cm (8 to 36 inches) UL Recognized, CSA certified. CE units available by request Note: These switches are not recommended for controlling electrial loads less than 100 ma, 12 VAC. Must be used with pumps that provide integral thermal overload protection. MODEL SPECIFIC SPECIFICATIONS Voltage 50 Hz/60 Hz Single Phase SJE MICROMASTER pump float Maximum Pump Running Current Maximum Pump Starting Current 125/250 VAC 10 amps 60 amps Cable: 18 gauge, 2 conductor Voltage 50 Hz/60 Hz Single Phase SJE MICROMASTER Plus pump float Maximum Pump Running Current Maximum Pump Starting Current 125/250 VAC 13 amps 60 amps Cable: 16 gauge, 2 conductor Pump Floats Voltage 50 Hz/60 Hz Single Phase SJE MICROMASTER SPDT pump float Maximum Pump Running Current Maximum Pump Starting Current 125/250 VAC 10 amps 60 amps Cable: 18 gauge, 3 conductor Can be wired to operate in either pump down (normally open) or pump up (normally closed) applications. Single Pole, Double Throw SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 53

56 SJE MICROMASTER, SJE MICROMASTER PLUS, SJE MICROMASTER SPDT Pump Floats Pump Floats Mechanically-activated, wide-angle switch designed for performance and dependability. ORDERING INFORMATION OPTIONS Bagged Packaging is standard - For individual boxed or bulk packaging, please contact the factory. Additional Cable Lengths are available Piggy-Back Plug - North American standard plug. Options are available for SJE MicroMaster and SJE MicroMaster Plus pump switches. customer.service@sjerhombus.com Please contact the factory. 54 SJE MICROMASTER Pump Float PART NUMBER DESCRIPTION SHIPPING Pump Down Pump Up Cable Length Mounting Device WEIGHT Meters Mounting Clamp 0.48 kg Meters Cable Weight 1.31 kg Meters Mounting Clamp 0.68 kg Meters Cable Weight 1.52 kg Meters Mounting Clamp 0.79 kg Meters Cable Weight 1.63 kg Meters Mounting Clamp 1.21 kg Meters Cable Weight 2.04 kg SJE MICROMASTER PLUS Pump Float PART NUMBER DESCRIPTION SHIPPING Pump Down Pump Up Cable Length Mounting Device WEIGHT Meters Mounting Clamp 0.49 kg Meters Cable Weight 1.32 kg Meters Mounting Clamp 0.69 kg Meters Cable Weight 1.53 kg Meters Mounting Clamp 0.80 kg Meters Cable Weight 1.64 kg Meters Mounting Clamp 1.22 kg Meters Cable Weight 2.05 kg SJE MICROMASTER SPDT Pump Float PART NUMBER DESCRIPTION SHIPPING Normally Open or Normally Closed Cable Length Mounting Device WEIGHT Meters Mounting Clamp 0.57 kg Meters Cable Weight 1.33 kg Meters Mounting Clamp 0.70 kg Meters Cable Weight 1.55 kg Meters Mounting Clamp 0.81 kg Meters Cable Weight 1.67 kg Meters Mounting Clamp 1.22 kg Meters Cable Weight 2.06 kg Pump Down is normally open contacts for emptying. Pump Up is normally closed contacts for filling. SJE MicroMaster SPDT pump switch has 3 conductors for pump down and pump up operation. SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING A SJE-Rhombus 02/17

57 Pump Floats SJE PUMPMASTER WPS Float Switch Mechanically-activated, wide-angle switch designed for direct control of pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC or control applications as low as 120 VAC, 100 ma. These mechanically-activated, wide-angle switches provide automatic control of pumps in: Potable water applications Water applications It can be wired to work in either pump down (normally open) or pump up (normally closed) applications (Single Pole, Double Throw). The SJE PumpMaster WPS float switch is not sensitive to rotation or turbulence allowing it to be used in both calm and turbulent applications. GENERAL SPECIFICATIONS Flexible SJOW, water-resistant (CPE) cable High impact, corrosion resistant, PVC float housing Temperature rating up to 60º C (140º F) For direct wiring applications IPX8 enclosure rating Float dimensions: 7.75 cm diameter x 9.04 cm long (3.05 inch x 3.56 inch) Adjustable pumping range of 18 to 91 cm (7 to 36 inches) Heavy-duty contacts CSA Certified to meet NSF/ANSI 61 standard for use in potable water. Approved for use in tanks of 950L (250 US gallon) in volume or greater per float. Note: This switch is not intended to control non-arching loads. MODEL SPECIFIC SPECIFICATIONS C US Drinking Water NSF/ANSI 61 Voltage 50 Hz/60 Hz Single Phase SJE PUMPMASTER pump float Maximum Pump Running Current Maximum Pump Starting Current 120/230 VAC 13 amps 85 amps Cable: 16 gauge, 3 conductor Minimum Electrical Load: 120 VAC, 100 ma active contacts CLOSED active contacts OPEN SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 55

58 Pump Floats SJE PUMPMASTER WPS Float Switch Mechanically-activated, wide-angle switch designed for direct control of pumps up to 1/2 HP at 120 VAC and 1 HP at 230 VAC or control applications as low as 120 VAC, 100 ma. ORDERING INFORMATION PART NUMBER SJE PUMPMASTER WPS Float Switch Cable Length DESCRIPTION Mounting Device Pump Down is normally open contacts for emptying. Pump Up is normally closed contacts for filling. SJE PumpMaster WPS float switch has 3 conductors for pump down and pump up operation. Boxed Packaging is standard. SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING. SHIPPING WEIGHT Meters Weighted Externally 1.84 kg 56 customer.service@sjerhombus.com A SJE-Rhombus 02/17

59 SJE PUMPMASTER, SJE PUMPMASTER PLUS, SJE PUMPMASTER SPDT Pump Floats Mechanically-activated, wide-angle pump switch designed for performance and dependability. These mechanically-activated, wide-angle switches provide automatic control of pumps in: Water Sewage applications These pump switches are not sensitive to rotation or turbulence allowing them to be used in both calm and turbulent applications. GENERAL SPECIFICATIONS Flexible SJOW, water-resistant (CPE) cable High impact, corrosion resistant, PVC float housing Temperature rating up to 60º C (140º F) Maximum water depth of 14 meters (46 feet) or 138 kpa (20 psi) IPX8 enclosure rating Float dimensions: 7.75 cm diameter x 9.04 cm long (3.05 inch x 3.56 inch) Adjustable pumping range of 18 to 91 cm (7 to 36 inches) Heavy-duty contacts UL Recognized, CSA certified Note: These switches must be used with pumps that provide integral thermal overload protection. MODEL SPECIFIC SPECIFICATIONS Voltage 50 Hz/60 Hz Single Phase SJE PUMPMASTER pump float Maximum Pump Running Current Maximum Pump Starting Current 125/250 VAC 13 amps 85 amps Cable: 16 gauge, 2 conductor Voltage 50 Hz/60 Hz Single Phase SJE PUMPMASTER PLUS pump float Maximum Pump Running Current Maximum Pump Starting Current 125/250 VAC 15 amps 85 amps Cable: 14 gauge, 2 conductor Pump Floats Voltage 50 Hz/60 Hz Single Phase SJE PUMPMASTER SPDT pump float Maximum Pump Running Current Maximum Pump Starting Current 125/250 VAC 13 amps 85 amps Cable: 16 gauge, 3 conductor Can be wired to operate in either pump down (normally open) or pump up (normally closed) applications. (Single Pole, Double Throw) SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 57

60 SJE PUMPMASTER, SJE PUMPMASTER PLUS, SJE PUMPMASTER SPDT Pump Floats Mechanically-activated, wide-angle pump switch designed for performance and dependability. ORDERING INFORMATION Pump Floats OPTIONS SJE PUMPMASTER Pump Float PART NUMBER DESCRIPTION SHIPPING Pump Down Pump Up Cable Length Mounting Device WEIGHT Meters Mounting Clamp 0.58 kg Meters Cable Weight 1.42 kg Meters Mounting Clamp 0.79 kg Meters Cable Weight 1.63 kg Meters Mounting Clamp 0.88 kg Meters Cable Weight 1.73 kg Meters Mounting Clamp 1.33 kg Meters Cable Weight 2.17 kg SJE PUMPMASTER PLUS Pump Float PART NUMBER DESCRIPTION SHIPPING WEIGHT Pump Down Pump Up Cable Length Mounting Device Meters Mounting Clamp 0.70 kg Meters Mounting Clamp 0.93 kg Meters Mounting Clamp 0.88 kg Meters Mounting Clamp 1.52 kg SJE PUMPMASTER SPDT Pump Float PART NUMBER DESCRIPTION SHIPPING Normally Open or Normally Closed Cable Length Mounting Device WEIGHT Meters Mounting Clamp 0.68 kg Meters Cable Weight 1.52 kg Meters Mounting Clamp 0.89 kg Meters Cable Weight 1.72 kg Meters Mounting Clamp 0.99 kg Meters Cable Weight 1.83 kg Meters Mounting Clamp 1.41 kg Meters Cable Weight 2.25 kg Pump Down is normally open contacts for emptying. Pump Up is normally closed contacts for filling. SJE PumpMaster SPDT pump switch has 3 conductors for pump down and pump up operation. SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING. Bagged Packaging is standard - For individual boxed or bulk packaging, please contact the factory. Additional Cable Lengths are available Piggy-Back Plug - North American standard plug. Options are available for SJE PumpMaster and SJE PumpMaster Plus pump switches. Please contact the factory customer.service@sjerhombus.com A SJE-Rhombus 02p/17

61 SJE AMPMASTER Pump Floats Mechanically-activated, wide-angle 20 amp rated switch designed to control pumps up to 1 1/2 HP at 125 VAC and 3 HP at 250 VAC. This mechanically-activated, wide-angle 20 amp rated pump switch provides automatic control of grinder and high head sewage pumps in grinder and lift station applications, as well as septic tank effluent pump (STEP) systems. The SJE AmpMaster pump switch is not sensitive to rotation or turbulence allowing it to be used in both calm and turbulent applications. Available for pump down applications only. GENERAL SPECIFICATIONS Flexible SJOW, water-resistant (CPE) cable High impact, corrosion resistant, PVC float housing Temperature rating up to 50º C (120º F) Maximum water depth of 14 meters (46 feet) or 138 kpa (20 psi) Float dimensions: 7.75 cm diameter x 9.04 cm long (3.05 inch x 3.56 inch) Adjustable pumping range of 23 to 61 cm (9 to 24 inches) Heavy-duty contacts mounted on high conductivity copper substrates. UL Recognized, CSA certified Note: This switch must be used with pumps that provide integral thermal overload protection. Certain pump applications may require the use of an external capacitor start kit. SPECIFICATIONS SJE AMPMASTER pump float Voltage 50 Hz/60 Hz Single Phase Maximum Pump Running Current Maximum Pump Starting Current 125/250 VAC 20 amps 120 amps Cable: 12 gauge, 2 conductor active contacts CLOSED non-conductive contacts Pump Floats active contacts OPEN non-conductive contacts SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 59

62 Pump Floats Mechanically-activated, wide-angle 20 amp rated switch designed to control pumps ORDERING INFORMATION OPTIONS PART NUMBER Pump Down Only SJE AMPMASTER Pump Floats up to 1 1/2 HP at 125 VAC and 3 HP at 250 VAC. SJE AMPMASTER Pump Float Cable Length DESCRIPTION Plug Configuration Mounting Clamp is standard Bagged Packaging is standard - For individual boxed packaging, please contact the factory Additional Cable Lengths are available - Please contact the factory. SHIPPING WEIGHT Meters No Plug 0.70 kg Meters No Plug 0.98 kg Meters No Plug 1.12 kg Meters No Plug 1.67 kg Pump Down is normally open contacts for emptying. SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING customer.service@sjerhombus.com A SJE-Rhombus 02/17

63 SJE HI TEMP MASTER Pump Float Mechanically-activated, wide-angle pump switch specifically designed for performance and dependability in high temperature sump applications up to 93 C (200 F). This mechanically-activated, wide-angle switches provide automatic control of pumps in: Water Sewage applications This SJE HiTempMaster pump switch is not sensitive to rotation or turbulence allowing it to be used in both calm and turbulent applications. Available for pump down applications only. GENERAL SPECIFICATIONS Flexible SJOOW, water-resistant (CPE) cable High impact, corrosion resistant, polypropylene float housing Temperature rating up to 93º C (200º F) Maximum water depth of 10 meters (33 feet) or 90 kpa (13 psi) Float dimensions: 8.1 cm diameter x 14.2 cm long (3.18 inch x 5.58 inch) Adjustable pumping range of 20 to 91 cm (8 to 36 inches) Mechanically-activated, snap action contacts CSA certified Note: This switch must be used with pumps that provide integral thermal overload protection. MODEL SPECIFIC SPECIFICATIONS Voltage 50 Hz/60 Hz Single Phase SJE HI TEMP MASTER pump float Maximum Pump Running Current Maximum Pump Starting Current 125/250 VAC 13 amps 78 amps Cable: 16 gauge, 2 conductor Pump Floats SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 61

64 Mechanically-activated, wide-angle pump switch specifically designed for performance and dependability in high temperature sump applications up to 200 F (93 C). ORDERING INFORMATION SJE HI TEMP MASTER Pump Float SJE HI TEMP MASTER Pump Float PART NUMBER DESCRIPTION SHIPPING Pump Down Cable Length Plug Configuration WEIGHT Meters 120V PiggyBack Plug 0.78 kg Meters 230V PiggyBack Plug 0.79 kg Meters No Plug 0.74 kg Meters 120V PiggyBack Plug 1.07 kg Meters 230V PiggyBack Plug 1.08 kg Meters No Plug 1.03 kg Meters 120V PiggyBack Plug 1.37 kg Meters 230V PiggyBack Plug 1.39 kg Meters No Plug 1.33 kg Pump Down is normally open contacts for emptying. SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING. Mounting Clamp is standard. Piggy-Back Plug - North American standard plug. Boxed Packaging is standard. Pump Floats 62 customer.service@sjerhombus.com A SJE-Rhombus 02/17

65 SJE VERTICALMASTER II and SJE VERTICALMASTER II PLUS Pump Floats Mechanically-activated, pump switches designed to operate in sump applications with limited space. These mechanically-activated pump switches are designed to operate in non-potable water with limited space. They work well in small sump chambers and laundry trays, as well as in large tanks. These switches are not recommended for a sewage environment. These switches not sensitive to turbulence. Available for pump down applications only. U.S. Patent No. 6,140,925 CA Pats. 2,367,577 and 2,694,446 Euro Pat German Pat. DE T2 China Pat GENERAL SPECIFICATIONS Flexible SJTOW, SJTW cable Stainless steel mounting bracket and hose clamp Acetal plastic lift rod Neoprene float stop High impact, corrosion resistant, PVC float and switch housing Temperature rating up to 52º C (125º F) IPX7 enclosure protection Suitable for Category 11 installations Protected by double-insulation Adjustable pumping range 2 cm to 17 cm (0.75 inches to 6.5 inches) Dimensions: Overall dimensions: 30.5 cm high x 12.7 cm x 7.6 cm wide (12 inch high x 5 inch x 3 inch wide) Switch housing dimensions (excluding cable entrance): 5 cm high x 7.1 cm diameter (2 inch high x 2.8 inch diameter) Float housing dimensions: 6.4 cm high x 6.9 cm diamter (2.5 inch high x 2.7 inch diameter) UL recognized, CSA certified for non-arcing loads, *CE units available by request Must be used with pumps that provide integral thermal overload protection. MODEL SPECIFIC SPECIFICATIONS Voltage 50 Hz/60 Hz Single Phase SJE VERTICALMASTER II pump float Maximum Pump Running Current Maximum Pump Starting Current 125/250 VAC 10 amps 60 amps Cable: 18 gauge, 2 conductor * Top View / Contacts Open Top View / Contacts Closed Pump Floats Voltage 50 Hz/60 Hz Single Phase SJE VERTICALMASTER II PLUS pump float Maximum Pump Running Current Maximum Pump Starting Current 125/250 VAC 13 amps 78 amps Cable: 16 gauge, 2 conductor SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 63

66 SJE VERTICALMASTER II and SJE VERTICALMASTER II PLUS Pump Floats Mechanically-activated, pump switches designed to operate in sump applications with limited space. ORDERING INFORMATION PART NUMBER Pump Down Only SJE VERTICALMASTER II Pump Float Cable Length DESCRIPTION Plug Configuration SHIPPING WEIGHT Meters No Plug 0.75 kg Meters No Plug 0.94 kg Meters No Plug 1.07 kg Meters No Plug 1.38 kg PART NUMBER Pump Down Only SJE VERTICALMASTER II PLUS Pump Float Cable Length DESCRIPTION Plug Configuration SHIPPING WEIGHT Meters No Plug 0.75 kg Meters No Plug 0.94 kg Meters No Plug 1.07 kg Meters No Plug 1.38 kg Pump Floats Pump Down is normally open contacts for emptying. SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING. OPTIONS Mounting Bracket and Hose Clamp are standard Boxed Packaging is standard - Bulk packaging is not available. Additional Cable Lengths are available - Please contact the factory. Piggy-Back Plug - North American standard plug. Please contact the factory customer.service@sjerhombus.com A SJE-Rhombus 02/17

67 EZconnex Float Switch Connection System Manifold/float connection system designed for easy installation of float switches in a wet well for level control applications. The EZconnex Float Switch Connection System includes (A) an electrical wiring manifold with (B) mounting bracket and hardware. The manifold features three quick release float switch connection ports. A single 6-conductor direct burial cable has Red-Blue-Yellow wire pairs that match the R-B-Y imprint on the manifold housing for easy field wiring. The mounting bracket is designed to allow quick access to the manifold and float switches for easy maintenance. (C) EZconnex float switches feature an internal switching mechanism with sealed gold crosspoint contacts for reliable low current operation. A range of wide-angle or narrow-angle float switches feature a quick release connection that simply plugs into the manifold port(s) for easy installation. The EZconnex system can be used with 1, 2, or 3 float switches. Each float switch includes a (D) protective rubber boot that provides a dual seal design for an extra layer of protection to keep connections clean and dry. (E) Sealing plugs are available for unused manifold port(s). NOTE: Do not install with open port(s). FEATURES Includes mounting bracket and hardware Rated for short term water submersion Designed for use with EZconnex float switches (not included with manifold; float switches must be ordered separately): Low current applications down to 0.160mA at 125V Mechanically-activated, snap action contacts Colored caps for easy identification of normally open (blue cap) or normally closed (red cap) models Activation angle above/below horizontal: cm (4 ) wide-angle; 3.81 cm (1.5 ) narrow-angle OPTIONS MANIFOLD: Standard cable lengths of 7.62, 15.24, or m (25, 50, or 100 ft) Sealing plug (includes rubber boot) required for unused port(s) FLOAT SWITCH: Standard cable lengths of 1.52, 3.05, 6.10 m (5, 10, or 20 ft) Blue cap for normally open (high level) applications or red cap for normally closed (low level) applications With narrow or wide-angle pumping ranges Standard mounting clamp for applications where the switch can be attached to a discharge pipe or similar mounting device SPECIFICATIONS MANIFOLD: Cable: Direct Burial Shielded PVC Type TC-ER TFFN (UL) 600V 18 gauge, 6-conductor Housing: ABS Plastic Electrical: 125 VAC: Max. Electrical Load: 1 amp per connection port FLOAT SWITCH: Cable: flexible 18 gauge, 2-conductor (UL, CSA) SJOW, water-resistant (CPE) Float: 7.0 diameter x 12.3 cm long (2.74 x 4.83 ), high-impact, corrosion resistant, polypropylene housing for use in sewage and water up to 60 o C (140 o F) Max. Water Depth: 9 m (30 ft), 90 kpa (13 PSI) Electrical: 125 VAC: Max. Electrical Load: 1 amp, Min. Electrical Load: ma 30 VDC: Max. Electrical Load: 1 amp, Min. Electrical Load: ma 5 VDC: Min. Electrical Load: 1 ma SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. A Patent Pending PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 65 C E D B Control Floats

68 Control Floats EZconnex Float Switch Connection System Manifold/float connection system designed for easy installation of float switches in a wet well for level control applications. ORDERING INFORMATION EZconnex Manifold PART NUMBER DESCRIPTION SHIPPING WEIGHT EZconnex with mounting bracket, 7.62 m (25 ft) 1.51 kg EZconnex with mounting bracket, m (50 ft) 2.37 kg EZconnex with mounting bracket, m (100 ft) 4.21 kg Normally Open EZconnex Float Switch Normally Closed PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION SHIPPING WEIGHT MAPNPCNOEZ MAPNPCNCEZ 0.39 kg MAPWPCNOEZ MAPWPCNCEZ 0.39 kg MAPNPCNOEZ MAPNPCNCEZ 0.52 kg MAPWPCNOEZ MAPWPCNCEZ 0.52 kg MAPNPCNOEZ MAPNPCNCEZ 0.81 kg MAPWPCNOEZ MAPWPCNCEZ 0.81 kg OPTIONS PART NUMBER DESCRIPTION SHIPPING WEIGHT Sealing plug (includes rubber boot) 0.07 kg N = Narrow Angle W = Wide Angle PC = Pipe Clamp NO = Normally Open NC = Normally Closed EZ = EZconnex *One sealing plug must be ordered for each unused port. Do not install with open port(s). SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING customer.service@sjerhombus.com A SJE-Rhombus 02/17

69 SJE MEGAMASTER (CSA) Control Float Mechanically-activated, narrow-angle float switch designed for level control of municipal wastewater pumping stations. The SJE MegaMaster mechanically-activated, internally weighted control float is designed for municipal water and sewage applications, including applications with high grease content. The internal switching mechanism has gold cross-point contacts for reliable control of current up to 1 amp. The unique two-color float housing offers easy identification of float position. Common applications include lift stations, non-potable water, PLC (programmable logic controllers) and intrinsically safe applications. When wired as Normally (high level) The control float turns on (closes) when the float tips slightly above horizontal signaling a high level, and turns off (opens) when the float drops slightly below horizontal. When wired as Normally Closed (low level) The control float turns on (closes) when the float tips slightly below horizontal signaling a low level, and turns off (opens) when the float tips slightly above horizontal. GENERAL SPECIFICATIONS Mechanically-activated, internally weighted Maximum Electric Load: 1 amp, 125 VAC Minimum Electric Load: 1mA, 4 VDC 3 wire cable - SPDT (Single Pole, Double Throw) can be wired as normally open or normally closed. Wire color: Common (white), N.O. (black), N.C. (red). Cable: 18 gauge, 3 conductor, SJOW Activation angle is 10 o above/below horizontal Flexible SJOW, water-resistant (CPE) jacket High impact, corrosion resistant, polypropylene float housing Temperature rating up to 60 o C (140 o F) Maximum water depth of 9 meters (30 feet) or 90 kpa (13 PSI) Float dimensions: 10.2 cm diameter x cm long (4.03 x 6.62 inch) CSA Certified Normally Open Wiring Connection Normally Closed Wiring Connection Control Floats SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 67

70 Control Floats ORDERING INFORMATION OPTIONS Bagged Packaging is standard. SJE MEGAMASTER (CSA) Control Float Mechanically-activated, narrow-angle float switch designed for level control of municipal wastewater pumping stations. PART NUMBER Normally Open or Normally Closed SJE MEGAMASTER Control Float Cable Length DESCRIPTION Mounting Device SHIPPING WEIGHT Meters Internal Weight 1.60 kg Meters Internal Weight 2.30 kg Meters Internal Weight 3.02 kg Meters Internal Weight 3.72 kg Options PART NUMBER DESCRIPTION SHIPPING WEIGHT Float Bracket with Mounting Device 1.01 kg Normally Open (High Level) Operation - The float switch closes (turns on) when the switch tips slightly above horizontal signaling a high level, and opens (turns off) when the float switch drops slightly below horizontal in water or sewage applications. Normally Closed (Low Level) Operation - The float switch closes (turns on) when the switch drops slightly below horizontal signaling a low level, and opens (turns off) when the float switch tips slightly above horizontal in water or sewage applications. SJE MegaMaster float switch has 3 conductors for normally open or normally closed operation. SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING customer.service@sjerhombus.com A SJE-Rhombus 02/17

71 SJE SIGNALMASTER and SJE SIGNALMASTER SPDT Control Floats Mechanically-activated, narrow-angle float switches designed to activate pump control panels and alarms. This narrow-angle sensing device is used to accurately monitor liquid levels in: Water Sewage applications The SJE SignalMaster control switch is not sensitive to rotation. Normally Open Model (high level) The control switch turns on (closes) when the switch tips slightly above horizontal signaling a high level, and turns off (opens) when the switch drops slightly below horizontal. Normally Closed Model (low level) The control switch turns on (closes) when the switch tips slightly below horizontal signaling a low level, and turns off (opens) when the switch tips slightly above horizontal. SPDT = Single Pole Double Throw GENERAL SPECIFICATIONS 125/250 VAC, 50/60 Hz, 5 Amps Flexible SJOW, water-resistant (CPE) cable High impact, corrosion resistant, polypropylene float housing Temperature rating up to 60º C (140º F) Maximum water depth of 9 meters (30 feet) or 90 kpa (13 psi) IPX8 enclosure protection Float dimensions: 7.0 cm diameter x 12.3 cm long (2.74 inch x 4.83 inch) Suitable for Category II installations Protected by double insulation UL Listed, CSA certified, *CE units available upon request Note: These switches are not recommended for controlling electrical loads less than 100 milliamps, 12 VAC, or for non-arcing electrical loads. MODEL SPECIFIC SPECIFICATIONS SJE SIGNALMASTER control float Cable: 18 gauge, 2 conductor * SJE SIGNALMASTER SPDT control float Cable: 18 gauge, 3 conductor Can be wired to operate in either normally open or normally closed applications. (Single Pole, Double Throw) Control Floats SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 69

72 SJE SIGNALMASTER and SJE SIGNALMASTER SPDT Control Floats Mechanically-activated, narrow-angle float switches designed to activate pump control panels and alarms. ORDERING INFORMATION Control Floats OPTIONS SJE SIGNALMASTER Control Float PART NUMBER DESCRIPTION SHIPPING Normally Open Normally Closed Cable Length Mounting Device WEIGHT Meters Mounting Clamp 0.75 kg Meters Cable Weight 1.23 kg Meters Mounting Clamp 0.66 kg Meters Cable Weight 1.42 kg Meters Mounting Clamp 0.76 kg Meters Cable Weight 1.52 kg Meters Mounting Clamp 1.14 kg Meters Cable Weight 1.91 kg SJE SIGNALMASTER SPDT Control Float PART NUMBER DESCRIPTION SHIPPING Normally Open or Normally Closed Cable Length Mounting Device WEIGHT Meters Mounting Clamp 0.54 kg Meters Cable Weight 1.30 kg Meters Mounting Clamp 0.78 kg Meters Cable Weight 1.54 kg Meters Mounting Clamp 0.90 kg Meters Cable Weight 1.66 kg Meters Mounting Clamp 1.37 kg Meters Cable Weight 2.14 kg Normally Open (High Level) Operation - The control switch closes (turns on) when the switch tips slightly above horizontal signaling a high level, and opens (turns off) when the switch drops slightly below horizontal in water or sewage applications. Normally Closed (Low Level) Operation - The control switch closes (turns on) when the switch drops slightly below horizontal signaling a low level, and opens (turns off) when the switch tips slightly above horizontal in water or sewage applications. SJE SignalMaster SPDT pump switch has 3 conductors for normally open or normally closed operation. SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING. Bagged Packaging is standard - For individual boxed or bulk packaging, please contact the factory. Additional Cable Lengths are available - Please contact the factory customer.service@sjerhombus.com A SJE-Rhombus 02/17

73 SJE MILLIAMPMASTER Control Floats Mechanically-activated control switch designed to activate low current control panels and alarms. This wide-angle or narrow-angle control switch offers reliable low current control for AC and DC applications in water and sewage. The internal switching mechanism has sealed gold cross-point contacts for reliable low current operation. Common applications include PLC (programmable logic controller) panels, IS panels with intrinsically safe barriers, low current solar applications, and other low current control panels and alarms applications. The wide-angle version activates/deactivates approximately cm (4 inches) above and below horizontal with a 9 cm (3.5 inches) tether. The narrow angle version activates/deactivates at approximately 3.81 cm (1.5 inches) above and below horizontal with a 9 cm (3.5 inch) tether. It is not sensitive to rotation. Normally Open Model (high level) The control switch turns on (closes) when the switch tips above horizontal signaling a high level, and turns off (opens) when the switch drops below horizontal. Normally Closed Model (low level) The control switch turns on (closes) when the switch drops below horizontal signaling a low level, and turns off (opens) when the switch tips above horizontal. This switch is not sensitive to rotation. GENERAL SPECIFICATIONS Flexible SJOW, water-resistant (CPE) jacket High impact, corrosion resistant, polyproplene float housing Temperature rating up to 60º C (140º F) Maximum water depth of 9 meters (30 feet) or 90 kpa (13 psi) Float dimensions: 7.0 cm diameter x 12.3 cm long (2.74 inch x 4.83 inch) Mechanically-activated, snap action contacts Low current, non-arcing applications UL Listed for use in non-potable water and sewage CSA Certified SPECIFICATIONS SJE MILLIAMPMASTER control float Voltage Maximum Electrical Load Minimum Electrical Load 120 VAC 0.1 amps milliamps 30 VDC 0.1 amps milliamps 5 VDC - 1 milliamp Cable: 18 gauge, 2 conductor Control Floats SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 71

74 SJE MILLIAMPMASTER Control Floats Mechanically-activated control switch designed to activate low current control panels and alarms. ORDERING INFORMATION SJE MILLIAMPMASTER Control Float NARROW-ANGLE VERSIONS PART NUMBER DESCRIPTION SHIPPING WEIGHT Normally Open Normally Closed Cable Length Mounting Device Meters Mounting Clamp 0.48 kg Meters Cable Weight 1.31 kg Meters Mounting Clamp 0.68 kg Meters Cable Weight 1.52 kg Meters Mounting Clamp 0.79 kg Meters Cable Weight 1.63 kg Meters Mounting Clamp 1.21 kg Meters Cable Weight 2.04 kg WIDE-ANGLE VERSIONS Meters Mounting Clamp 0.48 kg Meters Cable Weight 1.31 kg Meters Mounting Clamp 0.68 kg Meters Cable Weight 1.52 kg Meters Mounting Clamp 0.79 kg Meters Cable Weight 1.63 kg Meters Mounting Clamp 1.21 kg Meters Cable Weight 2.04 kg Normally Open (High Level) Operation - The control switch closes (turns on) when the switch tips slightly above horizontal signaling a high level, and opens (turns off) when the switch drops slightly below horizontal in water or sewage applications. Normally Closed (Low Level) Operation - The control switch closes (turns on) when the switch drops slightly below horizontal signaling a low level, and opens (turns off) when the switch tips slightly above horizontal in water or sewage applications. SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING. OPTIONS Bagged Packaging is standard - For individual boxed packaging, please contact the factory. Additional Cable Lengths are available - Please contact the factory. Control Floats 72 customer.service@sjerhombus.com A SJE-Rhombus 02/17

75 Mercury-activated, narrow-angle float switches designed to activate pump control panels and alarms. This narrow-angle sensing device is used to accurately monitor liquid levels in sewage and nonpotable water applications. The Sensor Float control switch is not sensitive to rotation and is suitable for use with intrinsically safe circuits. Contact SJE-Rhombus regarding specific intrinsically safe applications. Normally Open Model (high level) The control switch turns on (closes) when the switch tips slightly above horizontal signaling a high level, and turns off (opens) when the switch drops slightly below horizontal. Normally Closed Model (low level) The control switch turns on (closes) when the switch tips slightly below horizontal signaling a low level, and turns off (opens) when the switch tips slightly above horizontal. GENERAL SPECIFICATIONS SENSOR FLOAT and SENSOR FLOAT MINI Control Floats 125/250 VAC, 50/60 Hz, 5 Amps * Flexible 18 gauge, 2 conductor SJOW, water-resistant (CPE) cable High impact, corrosion resistant, PVC float housing Temperature rating up to 60º C (140º F) Maximum water depth of 9 meters (30 feet) or 90 kpa (13 psi) Mercury tilt switch: single pole, single throw, mercury to mercury contacts hermetically sealed in a steel capsule and epoxy sealed in a float housing Control differential of 1 cm (.5 inches) above or below horizontal IPX8 enclosure protection UL Listed, CSA certified MODEL SPECIFIC SPECIFICATIONS SENSOR FLOAT control float Float Dimensions: 8.58 cm diameter x cm long (3.38 inch x 4.55 inch) Suitable for use with intrinsically sale circuits. *CE Compliant units available upon request Suitable for Category II installations Protected by double insulation Three mounting options: Mounting clamp for applications where the switch can be attached to a discharge pipe or similar mounting device. Internally Weighted for applications where the switch can be suspended from above. Externally Weighted for applications where the switch can be suspended from above. SENSOR FLOAT MINI control float Float Dimensions: 7.14 cm diameter x 8.68 cm length (2.81 inch diameter x 3.42 inch length) Not recommended for controlling electrical load less than 100 milliamps, 12 VAC or for non-arcing electrical loads Two mounting options: Mounting clamp for applications where the switch can be attached to a discharge pipe or similar mounting device. Externally Weighted for applications where the switch can be suspended from above. Control Floats SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 73

76 SENSOR FLOAT and SENSOR FLOAT MINI Control Floats Mercury-activated, narrow-angle float switches designed to activate pump control panels and alarms. ORDERING INFORMATION Control Floats OPTIONS Bagged Packaging is standard - For individual boxed or bulk packaging, please contact the factory. Additional Cable Lengths are available - Please contact the factory. customer.service@sjerhombus.com 74 SENSOR FLOAT Control Float PART NUMBER DESCRIPTION SHIPPING Normally Open Normally Closed Cable Length Mounting Device WEIGHT Meters Mounting Clamp 0.89 kg Meters Internal Weight 1.14 kg Meters Cable Weight 1.74 kg Meters Mounting Clamp 1.09 kg Meters Internal Weight 1.34 kg Meters Cable Weight 1.94 kg Meters Mounting Clamp 1.21 kg Meters Internal Weight 1.47 kg Meters Cable Weight 2.07 kg Meters Mounting Clamp 1.58 kg Meters Internal Weight 1.83 kg Meters Cable Weight 2.43 kg Meters Mounting Clamp 2.45 kg Meters Internal Weight 2.79 kg Meters Cable Weight 3.35 kg SENSOR FLOAT MINI Control Float PART NUMBER DESCRIPTION SHIPPING Normally Open Normally Closed Cable Length Mounting Device WEIGHT Meters Mounting Clamp 0.51 kg Meters Cable Weight 1.36 kg Meters Mounting Clamp 0.71 kg Meters Cable Weight 1.56 kg Meters Mounting Clamp 0.83 kg Meters Cable Weight 1.68 kg Meters Mounting Clamp 1.20 kg Meters Cable Weight 2.05 kg Normally Open (High Level) Operation - The control switch closes (turns on) when the switch tips slightly above horizontal signaling a high level, and opens (turns off) when the switch drops slightly below horizontal in non-potable water, water or sewage applications. Normally Closed (Low Level) Operation - The control switch closes (turns on) when the switch drops slightly below horizontal signaling a low level, and opens (turns off) when the switch tips slightly above horizontal in nonpotable water, water or sewage applications. SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING A SJE-Rhombus 02/17

77 SUB-X Transmitter Submersible level transmitter designed for continuous level monitoring. The Sub-X transmitter measures the hydrostatic pressure of the water above the sensor and outputs a 4-20 ma signal proportional to the level. The robust design provides a reliable and low maintenance solution for level control applications, including: Sewage and effluent lift stations Stormwater pump stations Non-potable water systems Tanks, wet wells and reservoirs FEATURES Transmitter wetted components are designed with non-conductive materials to provide an electrical isolation barrier Pressure sensor isolated from process material by a protective VITON diaphragm Industry standard 4-20 ma, 2-wire loop powered Reverse polarity protected 18/2 shielded cable with vent tube Provided with removable lock in place stabilizing weight and stainless steel mounting bracket Multiple ranges SPECIFICATIONS Measuring Ranges: 7.25 PSI (16.7 ftwc) and PSI (33.4 ftwc) Accuracy: 1% full scale Operating Temp: 0-50 o C ( o F) Output: 4-20 ma, loop powered Excitation Voltage: 8-32 VDC reverse polarity protection Overpressure Protection: 58 PSI (133.6 ftwc) IP Rating: IP 68 for permanent submersion Wetted Materials: Sensor Housing: PVC, 51 mm diameter x 143 mm length (2.00 x 5.62 ) Cable Seal: EPDM Diaphragm: VITON, 32 mm diameter (1.25 ) Cable: TPE, 18 AWG 2-wire shielded with vent tube, 8 mm diameter (0.3 ) Stabilizing Weight: Epoxy coated cast iron, 0.45 kg (1.0 lb), 66 mm diameter x 64 mm length (2.6 x 2.5 ) Viton is a trademark of E. I. DuPont de Nemours and Company Corporation SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 75 Transmitter and Accessories

78 ORDERING INFORMATION SUB-X Transmitter Submersible level transmitter designed for continuous level monitoring. Sub-X Transmitter PART NUMBER MEASURING RANGE CABLE LENGTH SHIPPING WEIGHT bar (5.09 m/16.7 ft WC) 7.62 m (25 ft) 1.58 kg bar (5.09 m/16.7 ft WC) m (50 ft) 2.05 kg bar (5.09 m/16.7 ft WC) m (75 ft) 2.51 kg bar (5.09 m/16.7 ft WC) m (100 ft) 2.98 kg bar (10.18 m/33.4 ft WC) 7.62 m (25 ft) 1.58 kg bar (10.18 m/33.4 ft WC) m (50 ft) 2.05 kg bar (10.18 m/33.4 ft WC) m (75 ft) 2.51 kg bar (10.18 m/33.4 ft WC) m (100 ft) 2.98 kg WC = Water Column SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING. Transmitter and Accessories 76 customer.service@sjerhombus.com A SJE-Rhombus 02/17

79 ACCESSORIES CABLE WEIGHT Cable Weights, Cable Clamp Assembly, Float Bracket. Provides an accurate pivot point for suspended floats. Gripper teeth on clip and weight channel securely lock float cable into place. Cable Weight can be adjusted without the use of tools. Housing: 7.1 cm diameter x 8.4 cm (2.8 inch diameter x 3.3 inch long), impact resistant, non-corrosive, PVC housing for use in liquids up to 60 o C (140 o F). Clip: injection molded acetal plastic. Wire/Cable Accommodated: SJOW, SJTW, 18/2, 18/3, 16/2, 16/3, 14/2 and 14/3 U.S. Patent 5,306,885 Part Number Description Ship Weight Cable Weight 0.86 kg CABLE WEIGHT MINI Provides an accurate pivot point for suspended floats. One piece cable weight. Turn and lock for easy installation. Housing: 6.35 cm diameter x 6.35 cm long (2.5 inch diameter x 2.5 inch long), impact resistant, non-corrosive, PVC housing for use in liquids up to 60 o C (140 o F). Wire/Cable Accommodated: SJOW, SJTW, 18/2, 18/3 Part Number Description Ship Weight Cable Weight Mini 0.32 kg CABLE CLAMP ASSEMBLY Provides cable anchor point and strain relief. Secures cable in vertical direction. For use with 18/16 guage, 14 gauge, & 12 gauge cable. Mounting clamp: ABS nylon blend. Hose clamp: highly corrosion resistant stainless steel. Part Number Description Ship Weight & 16 gauge Cable Clamp Assembly 0.09 kg gauge Cable Clamp Assembly 0.09 kg gauge Cable Clamp Assembly 0.09 kg FLOAT BRACKET Provides convenient installation of floats. Six Float Bracket supports 1-6 floats. Four Float Bracket supports 1-4 floats. Can be directly mounted to wall or used with wall mounting device. Provides convenient location to stow excess float cord. Supplied with UL Recognized cord strain relief connectors. Metal Components: all metal components are made of 300 series stainless steel. Strain Relief Connectors: accomodates 18/2, 18/3, 16/2, 16/3 SJOW and SJTW cords. Part Number Description Ship Weight Float Bracket with Mounting Device 1.14 kg Float Bracket without Mounting Device 1.00 kg Float Bracket with Mounting Device 1.27 kg Float Bracket without Mounting Device 1.13 kg Float Bracket Mounting Device 0.14 kg INTERNATIONAL PRODUCT - NOT AVAILABLE FOR PURCHASE IN THE U.S. OR CANADA. SEE INTERNATIONAL PRICE BOOK FOR LIST PRICING. PO Box 1708, Detroit Lakes, MN Phone: customer.service@sjerhombus.com 77 Transmitter and Accessories

Visit worldwide link at

Visit worldwide link at Control Panels n Variable Frequency Drives Float Switches n Alarm Systems For Water/Wastewater Pump and Motor Control Visit worldwide link at www.sjerhombus.com 22650 County Highway 6 n PO Box 1708 n Detroit

More information

Control Panels Variable Frequency Drives Float Switches Alarm Systems For Water/Wastewater Pump and Motor Control. Visit worldwide link at

Control Panels Variable Frequency Drives Float Switches Alarm Systems For Water/Wastewater Pump and Motor Control. Visit worldwide link at Control Panels Variable Frequency Drives Float Switches Alarm Systems For Water/Wastewater Pump and Motor Control Visit worldwide link at www.sjerhombus.com 22650 County Highway 6 PO Box 1708 Detroit Lakes,

More information

product brochure Sump, Effluent and Sewage Controls

product brochure Sump, Effluent and Sewage Controls product brochure Sump, Effluent and Sewage Controls Control Panels, Alarms and Float Switches From the Controls Leader You Trust www.sjerhombus.com EZ Series This line of innovative, affordable control

More information

QUICK SHIP Products. Available for Same/Next Day Shipment at NO ADDITIONAL CHARGE!

QUICK SHIP Products. Available for Same/Next Day Shipment at NO ADDITIONAL CHARGE! QUICK SHIP Products Available for Same/Next Day Shipment at NO ADDITIONAL CHARGE! www.sjerhombus.com NEED PRODUCTS IN A HURRY? DON T WORRY! SJE-Rhombus is committed to being the best in the industry. In

More information

We ve Got Panels Under Control.

We ve Got Panels Under Control. We ve Got Panels Under Control Table of Contents CONTROL PANELS Page # RK Series Single Phase Simplex... A.1 RK Series Single Phase Duplex... A.3 RK Series Three Phase Simplex... A.5 RK Series Three Phase

More information

PRODUCT PRICE BOOK September 4, 2018

PRODUCT PRICE BOOK September 4, 2018 PRODUCT PRICE BOOK September 4, 2018 Control Panels Alarm Systems Float Switches Accessories Follow us on: www.sjerhombus.com ORDERING INFORMATION To assist us in delivering the exact product you want,

More information

PRODUCT PRICE BOOK January 1, 2019

PRODUCT PRICE BOOK January 1, 2019 PRODUCT PRICE BOOK January 1, 2019 Control Panels Alarm Systems Float Switches Accessories Follow us on: www.sjerhombus.com ORDERING INFORMATION To assist us in delivering the exact product you want, please

More information

2 SJE-Rhombus...The Name You Trust Above: Simplex - Below: Duplex Above: Simplex - Below: Duplex

2 SJE-Rhombus...The Name You Trust Above: Simplex - Below: Duplex Above: Simplex - Below: Duplex EZ Series Control Panels This line of innovative, affordable control panels is designed to make on-site installations easier. EZ Series control panels combine circuit board technology and easy operation

More information

PRODUCT PRICE BOOK JUNE 4, 2018

PRODUCT PRICE BOOK JUNE 4, 2018 PRODUCT PRICE BOOK JUNE 4, 2018 Control Panels Alarm Systems Float Switches Accessories Follow us on: www.sjerhombus.com ORDERING INFORMATION To assist us in delivering the exact product you want, please

More information

Custom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2

Custom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2 The Custom Controls Solution Provider Hydromatic has a reputation for providing dependable submersible pumps for wastewater lift stations and has continually raised the bar for quality products and customer

More information

Control Panel with Across The Line Starters

Control Panel with Across The Line Starters ECO SMART Station ATL Control Panel with Across The Line Starters The ECO SMART STATION ATL is a pre-engineered duplex control panel designed specifically for municipal lift station applications. Housed

More information

TECHNICAL BROCHURE BCALARM R4. Indoor and Outdoor Panels and Accessories

TECHNICAL BROCHURE BCALARM R4. Indoor and Outdoor Panels and Accessories TECHNICAL BROCHURE BCALARM R4 Indoor and Outdoor Panels and Accessories FEATURES Indoor and Outdoor alarm panels for sump, effluent and wastewater systems as well as test panel for troubleshooting. Use

More information

SJE-Rhombus Type IFS w/c-level Sensor Installation Instructions and Operation/Troubleshooting Manual

SJE-Rhombus Type IFS w/c-level Sensor Installation Instructions and Operation/Troubleshooting Manual Installer Friendly Series SJE-Rhombus Type IFS w/c-level Sensor Installation Instructions and Operation/Troubleshooting Manual This control panel must be installed and serviced by a licensed electrician

More information

Installer Friendly Series In-Site. Installation Instructions and Operation/Troubleshooting Manual. Installation. Mounting the Control Panel

Installer Friendly Series In-Site. Installation Instructions and Operation/Troubleshooting Manual. Installation. Mounting the Control Panel Installer Friendly Series In-Site SJE-Rhombus Type IFI Installation Instructions and Operation/Troubleshooting Manual This control panel must be installed and serviced by a licensed electrician in accordance

More information

Variable Frequency Drive SERIES MP800 VFD

Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controls and Accessories Variable Frequency Drive SERIES MP800 VFD Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for

More information

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G E SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF DATE: 11/13/06 2/1/07 1 Copyright, E, Inc. E 1. ENERAL...4 1.1 Scope Of Work... 4 1.2 Codes and Standards... 4 2. PRODUCTS...5

More information

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls Specification General The Powerex Laboratory Scroll Enclosed Air Compressor System is designed to provide clean, dry air for

More information

To Purchase This Item, Visit BMI Gaming (800) Super Scooper OPERATION MANUAL

To Purchase This Item, Visit BMI Gaming   (800) Super Scooper OPERATION MANUAL Super Scooper OPERATION MANUAL INTRODUCTION Thank you for purchasing the Super Scooper game machine (hereafter referred to as the machine ). This Operation Manual describes: How to install, operate, relocate,

More information

Soft Start Series MP700 Solid State, Reduced Voltage

Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controls and Accessories Soft Start Series MP700 Solid State, Reduced Voltage Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s

More information

SIMPLEX WEATHERPROOF CONTROL PANELS

SIMPLEX WEATHERPROOF CONTROL PANELS TECHNICAL BROCHURE BCP3 R10 FEATURES Rugged, NEMA 4X construction withstands even the most severe weather con ditions and prevents corrosion. Solid-state control board displays float status for ease of

More information

Across-the-Line SERIES MP300 Combined Manual and Automatic

Across-the-Line SERIES MP300 Combined Manual and Automatic Across-the-Line SERIES MP300 Combined Manual and Automatic Metron Fire Pump Controllers conform to the latest requirements of National Fire Protection Association s Standard for Centrifugal Fire Pumps

More information

VACUUM PUMP Model VCP-8101

VACUUM PUMP Model VCP-8101 VACUUM PUMP Model VCP-8101 Thank you for choosing the LMS Model VCP-8101 Vacuum Pump. Your Vacuum Pump is CE Certified and designed to be safe, reliable and easy to operate. Please read this thoroughly

More information

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL MYRIAD TPC VISIT OUR WEBSITE SIGMACONTROLS.COM MYRIADI&O062705 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING 7,8

More information

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass Project: Customer: Engineer: Pump Manufacturer: Submittal Document Model VPS Pressure Limiting (VFD) with Soft Start Bypass Contents: Data Sheets Dimensional Data Wiring Schematics Field Connections Note:

More information

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features. CONsOlIDATOR 4 & 8 MulTI- C h ANNEl CONTROllERs ConsoliDator 4 Model PD940 ConsoliDator 4 Features Four 4-20 Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Two 4-20 Outputs Common Features Four Pulse

More information

FTA550 JOCKEY PUMP CONTROLLERS

FTA550 JOCKEY PUMP CONTROLLERS FTA550 JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE SBP550E (A) FTA550E XG Jockey Pump Controllers Product Description Failed to start indication Main switch not in Auto alarm Pressure recording

More information

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU with Automatic Power Transfer Switch Contents: NOTE: The drawings included in this package are for controllers covered under our standard

More information

Tri-Stack Smart System

Tri-Stack Smart System Tri-Stack Smart System TM Notes & Warnings - The protection provided by this equipment may be impaired if it is not used in the manner specified herein. - Ensure all wiring meets applicable national and

More information

Wilo CO-Helix Booster Systems. Product Presentation July, 2017

Wilo CO-Helix Booster Systems. Product Presentation July, 2017 Wilo CO-Helix Booster Systems Product Presentation July, 2017 Pioneering for You Intelligent Pumps Save energy & optimize performance Technological innovation focus largest R&D development facility in

More information

Operation Manual. Programmable Logic Controller

Operation Manual. Programmable Logic Controller Operation Manual Programmable Logic Controller Part No. 9983-0000-E01 / January 2018 OPERATION MANUAL TABLE OF CONTENTS CUSTOMER SERVICE 3 CONTACT INFORMATION 3 ORDER INFORMATION 3 INTRODUCTION 4 THE PROCESS

More information

Drawing Submittal Package

Drawing Submittal Package Project: Customer: Engineer: Pump Manufacturer: Drawing Submittal Package Model GPL + GLU Limited Service Full Voltage Across the Line Start Electric Pump Controller with Automatic Power Transfer Switch

More information

This manual explains the features and operations of the VFDC controller which is specifically designed for Pressure Booster Pump Systems.

This manual explains the features and operations of the VFDC controller which is specifically designed for Pressure Booster Pump Systems. This manual explains the features and operations of the VFDC- 4100 controller which is specifically designed for Pressure Booster Pump Systems. The VFDC-4100 controller is capable of maintaining a constant

More information

THE MOST COMPLETE LINE OF SYSTEM ALARMS FLOAT SWITCHES ON-SITE ACCESSORIES CONTROL PANELS 24 HOUR SHIPPING ON ALL CATALOG ORDERS!

THE MOST COMPLETE LINE OF SYSTEM ALARMS FLOAT SWITCHES ON-SITE ACCESSORIES CONTROL PANELS 24 HOUR SHIPPING ON ALL CATALOG ORDERS! THE MOST COMPLETE LINE OF SYSTEM ALARMS FLOAT SWITCHES ON-SITE ACCESSORIES CONTROL PANELS 24 HOUR ON ALL CATALOG ORDERS! TABLE OF CONTENTS SYSTEM MONITORING DEVICES Plug-In Pedestal Alarm System... 4 High

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas User s Manual TIGER S EYE E-Series Mark V Jockey TIGERFLOW Systems, Inc. 4034 Mint Way Dallas, Texas 75237 214-337-8780 www.tigerflow.com TABLE OF CONTENTS Introduction... 4 Sequence of Operation... 5

More information

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers. ModSync Sequencing System Installation & Operation Manual For use with Fulton Steam Boilers. Revision 3.0 8/21/2008 - 2 - Table of Contents Introduction Page 4 Features Page 4 Sequence of Operation Page

More information

Lift Station Level Controller

Lift Station Level Controller Lift Station Level Controller Installation and Operation Manual 1 California Motor Controls, Inc. Benicia, CA Table of Contents 1. Features Product Overview... 4-6 Access Security... 7 Optional Features...

More information

Taking a Temperature

Taking a Temperature Taking a Temperature Body heat is measured by taking a temperature with a thermometer. An increase in temperature, called a fever, may be a sign of infection. The common scale used to measure body temperature

More information

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch Project: Customer: Engineer: Pump Manufacturer: Technical Data Submittal Document Model VPS + VPU Pressure Limiting (VFD) with Soft Start Bypass with Automatic Transfer Switch Contents: Data Sheets Dimensional

More information

FTA550F JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

FTA550F JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE FTA550F JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE SBP550F (A) FTA550F XG Jockey Pump Controllers Product Description Description Firetrol FTA550F XG Jockey Pump Controllers are intended for use

More information

CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S.

CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S. CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S. NAME OF TENDER: CONSTRUCT, DELIVER AND COMMISSION 3 (THREE) LIFT STATION ELECTRICAL LOCATION OF WORK: 3 Separate work sites in

More information

PRODUCT PRICE BOOK Pricing Effective February 4, We ve Got Panels Under Control.

PRODUCT PRICE BOOK Pricing Effective February 4, We ve Got Panels Under Control. PRODUCT PRICE BOOK Pricing Effective February 4, 2019 We ve Got Panels Under Control www.csicontrols.com ORDERING INFORMATION About this Price Booklet... This Suggested List Price Booklet is a consolidation

More information

MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7

MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7 MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7 VISIT OUR WEBSITE SIGMACONTROLS.COM MYRIAD DPC MANUAL 013114 1 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features

More information

PRODUCT NAME. Thermo-dryer MODEL. Original Instructions IDH4-10, IDH4-20, IDHA4-23 IDH6-10, IDH6-20, IDHA6-23

PRODUCT NAME. Thermo-dryer MODEL. Original Instructions IDH4-10, IDH4-20, IDHA4-23 IDH6-10, IDH6-20, IDHA6-23 IDX-OM-V018 1 st edition: December 2017 PRODUCT NAME Thermo-dryer MODEL Original Instructions IDH4-10, IDH4-20, IDHA4-23 IDH6-10, IDH6-20, IDHA6-23 This manual is intended to explain the installation and

More information

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3

Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Manufactured by SJE-Rhombus Installation Instructions and Operation/Troubleshooting Manual 7000 Apple Tree Avenue Bergen, New York 14416 Phone:

More information

Drawing Submittal Package

Drawing Submittal Package Project: Customer: Engineer: Pump Manufacturer: Drawing Submittal Package Model GPL + GLU Limited Service Full Voltage Across the Line Start Electric Pump Controller with Automatic Power Transfer Switch

More information

Specification Document. Single-circuit Embedded Water Leakage Detector AD-AS-1BM (RoHS-directive-compatible)

Specification Document. Single-circuit Embedded Water Leakage Detector AD-AS-1BM (RoHS-directive-compatible) To: Specification Document Single-circuit Embedded Water Leakage Detector AD-AS-1BM (RoHS-directive-compatible) Date:( ) System Equipment Division Electronic Materials & System Equipment

More information

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES GRUNDFOS CONTROL PANELS Simplex Panel Duplex Panel Standard Features LISTING: Underwriters Laboratories, UL 508. RATINGS: Model S1 rated up to 120 VAC, 1 Hp,

More information

2018 PRICING. alderonind.com STANDARD PRODUCTS

2018 PRICING. alderonind.com STANDARD PRODUCTS 2018 PRICING alderonind.com STANDARD PRODUCTS Terms & Conditions PURCHASE ORDERS Preferred via email: orders@alderonind.com If e-mail is not available, send via fax: 218.483.3036 SHIPPING INFORMATION MINIMUMS:

More information

DIESEL Engine Fire Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features September 007 DIESEL Engine Fire Pump Controllers Features FD0 Diesel Engine Controllers 1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller.

More information

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with

More information

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL GASGUARDIAN 2 3 2-Channel Controller OPERATING & INSTALLATION MANUAL GasGuardian 2 3 Operating and Installation Manual Table of Contents General description.... 3 Installation. 3 Locating the GasGuardian-2..

More information

FOCAS ppm Bilge Alarm. Product Specifications Rev.1.03 (T)

FOCAS ppm Bilge Alarm. Product Specifications Rev.1.03 (T) FOCAS-000 15ppm Bilge Alarm Product Specifications 01-06 Rev.1.03 (T) Alteration / correction hysteretic Date Revision The reason for revision / correction Approved Name 1 01-01-18 Rev.1.01 Internal Arrangement

More information

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification February 11, 2019 Master Panel Product Description The Master Panel shall provide lead/lag control and time based, automatic rotation of up to eight (8) boilers, when used in conjunction with LMV3 or LMV5

More information

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.

Three Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats. Three Phase Simplex Installation Instructions and Operation/Troubleshooting Manual This control panel must be installed and serviced by a licensed electrician in accordance with the National Electric Code

More information

Oxygen (O2) Single-Point Gas Detection System

Oxygen (O2) Single-Point Gas Detection System Oxygen (O) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in oxygen (O) sensor, accepts one analog remote device such as a secondary gas sensor, temperature or humidity

More information

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Nitrogen Dioxide (NO2) Single-Point Gas Detection System Nitrogen Dioxide (NO) Single-Point Gas Detection System DESCRIPTION Wall-mounted gas monitor with built-in nitrogen dioxide (NO)/diesel fume gas sensor, accepts one analog remote device such as a secondary

More information

Enclosed Scroll Air Compressor System SES 3-5 HP

Enclosed Scroll Air Compressor System SES 3-5 HP Enclosed Scroll Air Compressor SES 3-5 HP Specification General The Powerex Enclosed Scroll Air Compressor unit is designed to provide clean, dry air for industrial applications where the quality of the

More information

Liquid Level Alarms & Controls

Liquid Level Alarms & Controls 16/06/17 E14 Low Voltage High Water Alarm Protects your home from potential water flood damage by placing anywhere a water leak may exist Loud 85 db buzzer sounds for up to 18 hours Intermittent chirp

More information

Alarm Systems Alarm Bot CS2004E CS CS CS H2Oil Alarm System...12

Alarm Systems Alarm Bot CS2004E CS CS CS H2Oil Alarm System...12 TABLE OF CONTENTS Control Panels Page # Power Zone Jr. Simplex Float Panel...4 Power Zone Simplex Float Panel...4 Power Zone Duplex Float Panel...4 Fusion Economy...5 Fusion Simplex Float Panel...5 Fusion

More information

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT Simply Features In Brief Telemetry Ready Security 2 or 3 Pump Control UL Listed Alarm/Event Log Volumetric Flow Calculator VFD Control Optional Dialer

More information

PRODUCT NAME. Thermo-dryer MODEL. Original Instructions IDH4-10, IDH4-20, IDHA4-23 IDH6-10, IDH6-20, IDHA6-23

PRODUCT NAME. Thermo-dryer MODEL. Original Instructions IDH4-10, IDH4-20, IDHA4-23 IDH6-10, IDH6-20, IDHA6-23 IDX-OM-O025E-E 1 st edition: December 2010 6 th edition: November 2016 PRODUCT NAME Thermo-dryer MODEL Original Instructions IDH4-10, IDH4-20, IDHA4-23 IDH6-10, IDH6-20, IDHA6-23 This manual is intended

More information

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc MASTER JOCKEY PUMP CONTROLLER Model JPCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page 4 Model

More information

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL Installation and Operation Manual 2 GG-2 Warning Use this product only in the manner described in this manual. If the equipment is used in a manner not specified

More information

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc MASTER PRESSRE MAINTANENCE CONTROLLER Models PMCE INSTRUCTION MANUAL C 2018 Master Control Systems, Inc TABLE OF CONTENTS Important Safety Information. Page 3 General Description and Installation.. Page

More information

Oakton TEMP 9500 Advanced Multiparameter Controller

Oakton TEMP 9500 Advanced Multiparameter Controller Oakton TEMP 9500 Advanced Multiparameter Controller Models: 89800-03 & 89800-04 Oakton Instruments 625 E Bunker Ct. Vernon Hills, IL 60061, USA 1-888-4OAKTON (1-888-462-5866) info@4oakton.com Contents

More information

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers DIESEL Engine Fire Pump Controllers Features FD120 Diesel Engine Controllers 1-1 March 2013 Diesel Product Description The DIESEL Plus Fire Pump Controllers from Eaton Corporation are designed to control

More information

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design TOTAL SOLUTIONS Liquid Level Control Product Guide MATELEC innovative by design Liquid Level Control Contents Dual Pump Controllers Section 1 The Range Common Features Operating Data Control Logic Setup

More information

Technical Data Submittal Document

Technical Data Submittal Document Project: Customer: Engineer: Pump Manufacturer: Technical Data Submittal Document Model GPL + GLU Limted Service Full Voltage Across the Line Start Electric Fire Pump Controller Contents: Data Sheets Dimensional

More information

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014 January 16, 2014 Release Control Panel 290a 1. Description The Viking VFR400 is a microprocessor based releasing control panel for use on preaction, deluge, Surefire, Firecycle multicycle sprinkler systems,

More information

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY SECTION 22 11 23.13 DOMESTIC WATER PRESSURE BOOSTING PART 1 - GENERAL 1.1 SUMMARY A. Where utility water pressure cannot adequately meet the pressure requirements of the domestic water systems and where

More information

ESSEX ENGINEERING CORPORATION

ESSEX ENGINEERING CORPORATION WATER/WASTEWATER TREATMENT CONTROL SYSTEMS AND SUBSYSTEMS 2000 SERIES CONTROL SYSTEMS: 2000 series are for surface mounting inside a control cabinet Model 2024 Electronic Alternator Duplex (two pump) pump

More information

Combustible Gas Detection and Control System

Combustible Gas Detection and Control System Combustible Gas Detection and Control System DESCRIPTION Gas monitor with built-in combustible gas sensor, wall-mounted, accepts inputs from remote devices such as other gas sensors, temperature or humidity

More information

5 20 HP OIL-LESS ROTARY SCROLL COMPRESSOR. EnviroAire ES

5 20 HP OIL-LESS ROTARY SCROLL COMPRESSOR. EnviroAire ES 5 20 HP OIL-LESS ROTARY SCROLL COMPRESSOR EnviroAire ES Legendary Experience Innovative Design Gardner Denver has over 150 years of experience in manufacturing the highest quality compressors. The EnviroAire

More information

PUMP / CONTROL PANEL SWITCHES TECHNICAL BROCHURE BCPFS R10

PUMP / CONTROL PANEL SWITCHES TECHNICAL BROCHURE BCPFS R10 PUMP / CONTROL PANEL SWITCHES TECHNICAL BROCHURE BCPFS R10 TERMS TO KNOW Pump Switches are used to directly control the operation of a pump. They are normally wide-angle switches which means they operate

More information

Refrigerated Air Dryer

Refrigerated Air Dryer IDX-OM-N030-D 1 st edition: February 2010 6 th edition: March 2012 PRODUCT NAME Refrigerated Air Dryer MODEL Original Instructions IDFA100F-38-, IDFA100F-40- IDFA125F-38-, IDFA125F-40- IDFA150F-38-, IDFA150F-40-

More information

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. L Type Anchor Bolt Carbon Steel AISI 304 S.S. ANCHOR BOLT DETAIL Heavy Flat Washer Heavy Hex Nut UNC Th'd Mounting Flange Of Equipment To Be Mounted C B A D Non-Shrink Grout. Poured In Place, After Equipment Setting. Heavy Flat Washer Heavy Hex Nut

More information

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818) UCUF191S-86, UCUF241S-86 and UCUF281S-86 UPRIGHT ULTRACOLD FREEZERS Control and Alarm Features Manual defrost, adjustable control range from -50 C to -86 C. UL/CUL Listed. Factory preset at -80 C. Advanced

More information

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS SECTION 22 20 00 LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Division 1, "General Requirements",

More information

TECHNICAL BROCHURE BCPSDWWP R2 SIMPLEX/DUPLEX WASTEWATER DISCONNECT STYLE PANELS

TECHNICAL BROCHURE BCPSDWWP R2 SIMPLEX/DUPLEX WASTEWATER DISCONNECT STYLE PANELS TECHNICAL BROCHURE BCPSDWWP R SIMPLEX/DUPLEX WASTEWATER ONNECT STYLE PANELS PANEL FEATURES Oversize enclosure to accommodate all options. One main disconnect through-the-door with door interlock, prevents

More information

DIESEL Engine Fire Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features 1-1 Product Description The FD100 Diesel Engine Controller is designed to control and monitor 12 or 24 volt, diesel fire pump engines. All models are listed by UL and ULC, and approved by Factory Mutual

More information

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08 GasScanner 4C Four Channel Monitor Operator s Manual MINT-0280-XX Rev. A 02/25/08 Product Warranty Matheson Tri-Gas., warrants gas alarm equipment sold by us to be free from defects in materials, workmanship,

More information

SUPREMATouch. Modular Fire & Gas Detection System

SUPREMATouch. Modular Fire & Gas Detection System SUPREMATouch Modular Fire & Gas Detection System Fire & Gas Detection Solutions MSA permanent gas detection systems are used throughout the world to protect plant and personnel from hazardous gases in

More information

Automation and Energy Efficiency of Industrial Refrigeration Systems

Automation and Energy Efficiency of Industrial Refrigeration Systems Automation and Energy Efficiency of Industrial Refrigeration Systems E360 Forum Chicago, IL October 5, 2017 Mike Micak Director of Sales Logix Controls Introduction Management thinker Peter Drucker was

More information

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge Replaceable LED modules 11 Alarm Sequences as per ISA-18.1 standard Each channel/window fully field programmable RS232 or RS485 MODBUS-RTU communication Repeat relay for each window and multifunction relays

More information

SECTION 4000 LIFT STATIONS

SECTION 4000 LIFT STATIONS SECTION 4000 LIFT STATIONS LIFT STATIONS PART 1 GENERAL 1.01 Section Summary A. Lift station control panels. B. Related requirements include those established in the General Requirements Division 1, Division

More information

PRYCO, INC. FUEL CONTROL

PRYCO, INC. FUEL CONTROL PRYCO, INC. FUEL CONTROL and MONITORING SYSTEM Page 1 DETAIL SPECIFICATIONS INTRODUCTION PRYCO s FUEL CONTROL and MONITORING (FCM) system is the most sophisticated and powerful control tool available for

More information

R E C T I F I E R I N V E R T E R C O N V E R T E R SB7

R E C T I F I E R I N V E R T E R C O N V E R T E R SB7 SCR Battery Charger Product Specifications Description The is RIC Electronics premiere SCR battery charger/rectifier. The provides power to critical DC loads through a wide range of outputs and is engineered

More information

Installation and Operation Manual

Installation and Operation Manual SENTRY Protect Plus QUADPLEX PANEL Installation and Operation Manual For Hardwired Pumps Environment e Corporation Table of Contents 1 Overview...3 2 Sentry Protect Plus Quadplex Menu Flowchart...4 3 Wiring

More information

CAUTION & SYMBOL DEFINITIONS:

CAUTION & SYMBOL DEFINITIONS: 1441 Rice Street, St. Paul, MN 55117-3899 USA Phone (651) 487-8844 Fax (651) 487-8857 info@coolairinc.com www.coolairinc.com CAUTION & SYMBOL DEFINITIONS: LBW-50 SPECIFICATIONS (cont d) CAUTION: Gives

More information

Hydroflo Prepackaged Pumping Systems

Hydroflo Prepackaged Pumping Systems Hydroflo Prepackaged Pumping Systems Presented to: Presented by: John Curls Jr., P.E. BARNEY S PUMPS INC. What is it? Hydroflo A Hydroflo Packaged Pumping System provides variable volume at a constant

More information

Beacon 410A Gas Monitor Operator s Manual

Beacon 410A Gas Monitor Operator s Manual Beacon 410A Gas Monitor Operator s Manual Part Number: 71-0397 Revision: F Released: 12/5/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be

More information

Model 7700 Pump Director Valve and Pump Motor Interface Controller

Model 7700 Pump Director Valve and Pump Motor Interface Controller Model 7700 Pump Director Valve and Pump Motor Interface Controller A Century of Experience VAG GA Industries valves are known for long term reliability in the most demanding water and wastewater applications.

More information

SCC Inc. TS Series. Technical Instructions. Document No. TS 1000 June 25, TS Touchscreen Kits. Description. Touchscreen

SCC Inc. TS Series. Technical Instructions. Document No. TS 1000 June 25, TS Touchscreen Kits. Description. Touchscreen TS Touchscreen Kits for use with LMV3, LMV5 and RWF Controls June 25, 2018 Touchscreen Description Plate Kit Enclosure TS series touchscreen kits provide a human machine interface (HMI) with a Siemens

More information

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector CAUTION & SYMBOL DEFINITIONS: CAUTION: Gives detailed description of different situations to avoid or not avoid for the proper operation of the

More information

ChemScan mini Analyzer for Low Ammonia Monitoring Installation, Operation and Maintenance Manual

ChemScan mini Analyzer for Low Ammonia Monitoring Installation, Operation and Maintenance Manual ChemScan mini Analyzer for Low Ammonia Monitoring Installation, Operation and Maintenance Manual asaanalytics.com ChemScan mini Low Ammonia Analyzer O&M Manual - Rev 223K TABLE OF CONTENTS ANALYZER DESCRIPTION

More information

Safety Precautions 安全上の注意

Safety Precautions 安全上の注意 Safety Precautions 安全上の注意 English Foreword... For safe operation...3 Position of the warning label...7 日本語 はじめに... 0 安全にお使いいただくために... 警告ラベルについて... 4 MIMAKI ENGINEERING CO., LTD. https://mimaki.com/ D0906-3

More information

Piggyback Mechanical Float Switch. Piggyback Vertical Mechanical Float Switch. Piggyback Diaphragm Switch. Accessories

Piggyback Mechanical Float Switch. Piggyback Vertical Mechanical Float Switch. Piggyback Diaphragm Switch. Accessories Piggyback Mechanical Float Switch Piggyback Vertical Mechanical Float Switch Residential sewage waste transfer RFSN-6, RFSN-9 and RFSN-10 any manual pump, up through 3/4 convert any manual pump, up hp

More information

Oil Free Scroll Compressors

Oil Free Scroll Compressors INDUSTRIALS GROUP Oil Free Scroll Compressors EnviroAire S 4-15D Series Scroll Technology GARDNER DENVER COMPRESSED AIR TECHNOLOGIES Why oil-free? Don t compromise on quality The EnviroAire S series from

More information

Operational Overview and Controls Guide

Operational Overview and Controls Guide DOCUMENT: ECSEQ2-2 EFFECTIVE: 02/26/10 SUPERSEDES: 02/14/07 Operational Overview and Controls Guide Standard Two or Three Pump Type VFD Booster Controls 6700 Best Friend Road. Norcross, GA 30071. (770)

More information