- Views:
Transcription
1 PRODUCT PRICE BOOK Pricing Effective February 4, 2019 We ve Got Panels Under Control
2 ORDERING INFORMATION About this Price Booklet... This Suggested List Price Booklet is a consolidation of CSI Controls standard panels, alarms, and accessories. This price booklet corresponds to products from multiple product catalogs. If you have questions, please contact your Distributor, a CSI Sales Representative or the factory at Possession of this booklet or other CSI Controls product catalogs does not constitute an offer to sell. To be qualified as a Factory Direct customer, please contact a CSI Sales Representative or the factory. Prices, specifications, product offerings and policies are subject to change without notice. Placing an Order For Factory Direct Accounts, to assist us in delivering the exact product you want, please order by the seven digit part number or panel model number. If you do not find the product you are looking for in our catalog, please contact your Customer Service Representative at CSI Controls also manufacturers custom control panels. To order, contact your Customer Service Representative toll free at or via at customer.service@sjeinc.com. Order Shipping Standard catalog products, depending on volume and options, are shipped within five (5) business days from receipt of order. CSI ships in-stock items same day when requested. Control panels ordered with multiple options and orders exceeding $ may require up to ten (10) business days to ship. Large stocking control panel orders may require additional lead time of more than ten (10) business days. Next Day Air, Second Day Air and Three Day UPS Ground services are available to expedite orders. To receive these services, you must place your order before 1:00 p.m. Eastern Time. Warranty Return Policy CSI Controls offers a three-year limited warranty on most products. However, some product warranties may vary. For more information on warranties, please call Returned Material Authorization (RMA) numbers must be assigned to products being returned for a warranty claim. Contact your Customer Service Representative at for instructions on returning a product warranty. Prop 65 For all products in this book:
3 TABLE OF CONTENTS CONTROL PANELS Page # RK Series Single Phase Simplex Float Panel...2 RK Series Single Phase Duplex Float Panel...3 RK Series Three Phase Simplex Float Panel...4 RK Series Three Phase Duplex Float Panel...5 RK Series Single Phase Simplex Capacitor Start/Run...6 RK Series Single Phase Duplex Capacitor Start/Run...7 RK Series Displays...8 Fusion Economy...8 Fusion Single Phase Simplex Float Panel...9 Fusion Single Phase Duplex Float Panel...10 Power Zone Jr. Single Phase Simplex Float Panel...11 Power Zone Single Phase Simplex Float Panel...11 Power Zone Single Phase Duplex Float Panel...12 Minuteman Level Alert Pedestal...13 H2Oil Alarm System...13 VIP-331 Three Phase Duplex Panel...14 VIP-XR Three Phase Duplex Panel...14 ALARM SYSTEMS CS2004E...15 CS CS1200 WiFi...15 CS CS PUMP SWITCHES Page # Medium Duty Wide Angle Mechanical...16 Heavy Duty Wide Angle Mechanical...16 Medium Duty Wide Angle Mercury...16 Medium Duty Wide Angle Mini Mercury...17 Medium Duty Limited Space...17 Medium Duty Wide Angle Dual...17 High Temperature...17 CONTROL SWITCHES Speed-E Connect 3 Port Float Connection System...18 Speed-E Connect 4 Port Float Connection System...18 Control Duty Narrow Angle Extra Large Mechanical...19 Control Duty Narrow Angle Mechanical...19 Control Duty Narrow Angle Low Current Mechanical...19 Control Duty Narrow Angle Mercury...20 Control Duty Narrow Angle Mini Mercury...20 ACCESSORIES Pipe Mounts...21 Float Brackets...21 Pedestals...21 Cable Weights...21 SLX Transmitter...21 Vertical Reed Switch Ohio Street, Ashland, OH PH: FAX:
4 CONTROL PANELS **RK SERIES PANELS Single phase, simplex demand dose or timed dose float controlled system for pump control and system monitoring. RANGE **RK SERIES SINGLE PHASE SIMPLEX FLOAT PANELS Example with 20 foot Mechanical Floats and Auxiliary Alarm and Redundant Off Circuity : RKSF115-FC20-X = $ List CIRCUIT BREAKERS RKSF115CB 0-12 NEMA 4X Motor & Control $ RKSF115ACB 0-12 NEMA 4X Motor, Control & Alarm $ RKSF230CB 0-12 NEMA 4X Motor & Control $ RKSF230ACB 0-12 NEMA 4X Motor, Control & Alarm $ AMB Amber Beacon (red beacon is standard) $0 DC DCTD Digital Display Center Time Dosing DDC $90.00 $ FC20 (3) 20 foot mechanical control switches / pipe clamp $81.00 FC20CW (3) 20 foot mechanical control switches / cable weight $ FR20 (3) 20 foot mercury control switches / pipe clamp $93.00 FR20CW (3) 20 foot mercury control switches / cable weight $ FC30 (3) 30 foot mechanical control switches / pipe clamp $96.00 FC30CW (3) 30 foot mechanical control switches / cable weight $ FR30 (3) 30 foot mercury control switches / pipe clamp $ FR30CW (3) 30 foot mercury control switches / cable weight $ FC50 (3) 50 foot mechanical control switches / pipe clamp $ FC50CW (3) 50 foot mechanical control switches / cable weight $ FR50 (3) 50 foot mercury control switches / pipe clamp $ FR50CW (3) 50 foot mercury control switches / cable weight $ GR Gray Enclosure (black enclosure is standard) $0 HD1 Heavy Duty 1: Increase breakers & wire gauge to allow $21.00 HD2 Heavy Duty 2: Increase breakers & wire gauge to allow $32.00 HS Heat Sensor Terminals $21.00 HTR Anti-Condensation Heater $ IB IBTD Digital Interface Board Time Dosing DIB $ $ LA Lightning Arrestor $95.00 OL## Pump Overload - specify amperage after OL (Example: OL02 = 2 amp pump, OL20 = 20 amp pump) $ SF Seal Failure Indicator Light $48.00 X Auxiliary Alarm and Redundant Off Circuitry (control switch not included) $ Suggested List Price - Pricing Effective 02/04/19
5 CONTROL PANELS **RK SERIES PANELS Single phase, duplex demand dose or timed dose float controlled system for pump control and system monitoring. RANGE RK SERIES SINGLE PHASE DUPLEX FLOAT PANELS CIRCUIT BREAKERS RKDF115CB 0-12 NEMA 4X Motor & Control $ RKDF115ACB 0-12 NEMA 4X Motor, Control & Alarm $ RKDF230CB 0-12 NEMA 4X Motor & Control $ RKDF230ACB 0-12 NEMA 4X Motor, Control & Alarm $1, AMB Amber Beacon (red beacon is standard) $0 DC DCTD Digital Display Center Time Dosing DDC $ $ FC20 (4) 20 foot mechanical control switches / pipe clamp $ FC20CW (4) 20 foot mechanical control switches / cable weight $ FR20 (4) 20 foot mercury control switches / pipe clamp $ FR20CW (4) 20 foot mercury control switches / cable weight $ FC30 (4) 30 foot mechanical control switches / pipe clamp $ FC30CW (4) 30 foot mechanical control switches / cable weight $ FR30 (4) 30 foot mercury control switches / pipe clamp $ FR30CW (4) 30 foot mercury control switches / cable weight $ FC50 (4) 50 foot mechanical control switches / pipe clamp $ FC50CW (4) 50 foot mechanical control switches / cable weight $ FR50 (4) 50 foot mercury control switches / pipe clamp $ FR50CW (4) 50 foot mercury control switches / cable weight $ GR Gray Enclosure (black enclosure is standard) $0 HD1 Heavy Duty 1: Increase breakers & wire gauge to allow $32.00 HD2 Heavy Duty 2: Increase breakers & wire gauge to allow $42.00 HS Heat Sensor Terminals $42.00 HTR Anti-Condensation Heater $ IB IBTD Digital Interface Board Time Dosing DIB $ $ LA Lightning Arrestor $95.00 OL## Pump Overload - specify amperage after OL (Example: OL02 = 2 amp pump, OL20 = 20 amp pump) $ SF Seal Failure Indicator Lights $96.00 X Auxiliary Alarm and Redundant Off Circuitry (control switch not included) $48.00 Example with 30 Foot Mechanical Floats with Cable Weights: RKDF230CB-FC30CW = $1, List 2019 Suggested List Price - Pricing Effective 02/04/19 3
6 CONTROL PANELS **RK SERIES PANELS Three phase, simplex demand dose or timed dose float controlled system for pump control and system monitoring. AMB Amber Beacon (red beacon is standard) $0 DC DCTD Digital Display Center Time Dosing DDC Example with Time Dose DDC and 20 foot Mechanical Floats: RKSF DCTD -FC20= $1, List *3 phase 600 V option available. Please contact factory for details. $90.00 $ FC20 (3) 20 foot mechanical control switches / pipe clamp $81.00 FC20CW (3) 20 foot mechanical control switches / cable weight $ FR20 (3) 20 foot mercury control switches / pipe clamp $93.00 FR20CW (3) 20 foot mercury control switches / cable weight $ FC30 (3) 30 foot mechanical control switches / pipe clamp $96.00 FC30CW (3) 30 foot mechanical control switches / cable weight $ FR30 (3) 30 foot mercury control switches / pipe clamp $ FR30CW (3) 30 foot mercury control switches / cable weight $ FC50 (3) 50 foot mechanical control switches / pipe clamp $ FC50CW (3) 50 foot mechanical control switches / cable weight $ FR50 (3) 50 foot mercury control switches / pipe clamp $ FR50CW (3) 50 foot mercury control switches / cable weight $ GR Gray Enclosure (black enclosure is standard) $0 HS Heat Sensor Terminals $21.00 HTR Anti-Condensation Heater $ IB IBTD RANGE Digital Interface Board Time Dosing DIB **RK SERIES THREE PHASE SIMPLEX FLOAT PANELS CIRCUIT BREAKERS RKSF * NEMA 4X 208/240/460-3 Motor $1, RKSF * NEMA 4X 208/240/460-3 Motor $1, RKSF * NEMA 4X 208/240/460-3 Motor $1, RKSF * NEMA 4X 208/240/460-3 Motor $1, RKSF * NEMA 4X 208/240/460-3 Motor $1, RKSF * NEMA 4X 208/240/460-3 Motor $1, RKSF * NEMA 4X 208/240/460-3 Motor $1, RKSF * NEMA 4X 208/240/460-3 Motor $1, RKSF * NEMA 4X 208/240/460-3 Motor $1, RKSF * NEMA 4X 208/240/460-3 Motor $1, $ $ LA Lightning Arrestor $95.00 SF Seal Failure Indicator Light $48.00 X Auxiliary Alarm and Redundant Off Circuitry (control switch not included) $ Suggested List Price - Pricing Effective 02/04/19
7 CONTROL PANELS **RK SERIES PANELS Three phase, duplex demand dose or timed dose float controlled system for pump control and system monitoring. AMB Amber Beacon (red beacon is standard) $0 DC DCTD Digital Display Center Time Dosing DDC $ $ FC20 (4) 20 foot mechanical control switches / pipe clamp $ FC20CW (4) 20 foot mechanical control switches / cable weight $ FR20 (4) 20 foot mercury control switches / pipe clamp $ FR20CW (4) 20 foot mercury control switches / cable weight $ FC30 (4) 30 foot mechanical control switches / pipe clamp $ FC30CW (4) 30 foot mechanical control switches / cable weight $ FR30 (4) 30 foot mercury control switches / pipe clamp $ FR30CW (4) 30 foot mercury control switches / cable weight $ FC50 (4) 50 foot mechanical control switches / pipe clamp $ FC50CW (4) 50 foot mechanical control switches / cable weight $ FR50 (4) 50 foot mercury control switches / pipe clamp $ FR50CW (4) 50 foot mercury control switches / cable weight $ GR Gray Enclosure (black enclosure is standard) $0 HS Heat Sensor Terminals $42.00 HTR Anti-Condensation Heater $ IB IBTD RANGE Digital Interface Board Time Dosing DIB **RK SERIES THREE PHASE DUPLEX FLOAT PANELS CIRCUIT BREAKERS RKDF * NEMA 4X 208/240/460-3 Motor $1, RKDF * NEMA 4X 208/240/460-3 Motor $1, RKDF * NEMA 4X 208/240/460-3 Motor $1, RKDF * NEMA 4X 208/240/460-3 Motor $1, RKDF * NEMA 4X 208/240/460-3 Motor $1, RKDF * NEMA 4X 208/240/460-3 Motor $1, RKDF * NEMA 4X 208/240/460-3 Motor $1, RKDF * NEMA 4X 208/240/460-3 Motor $1, RKDF * NEMA 4X 208/240/460-3 Motor $1, RKDF * NEMA 4X 208/240/460-3 Motor $1, $ $ LA Lightning Arrestor $95.00 SF Seal Failure Indicator Lights $96.00 X Auxiliary Alarm and Redundant Off Circuitry (control switch not included) $48.00 Example with Gray Enclosure, Heat Sensor Terminals and Seal Failure Indicator Lights: RKDF GR-HS-SF = $1, List *3 phase 600 V option available. Please contact factory for details Suggested List Price - Pricing Effective 02/04/19 5
8 CONTROL PANELS **RK SERIES PANELS Single phase, simplex capacitor start/run demand dose or timed dose float controlled system for pump control and system monitoring. **RK SERIES SINGLE PHASE SIMPLEX CAPACITOR START/RUN FLOAT PANELS RANGE CIRCUIT BREAKERS RKSF230CBG 0-12 NEMA 4X Motor & Alarm, Capacitor Circuitry* $ RKSF230ACBG 0-12 NEMA 4X Motor, Control & Alarm, Capacitor Circuitry* $ AMB Amber Beacon (red beacon is standard) $0 DC DCTD Digital Display Center Time Dosing DDC $90.00 $ FC20 (3) 20 foot mechanical control switches / pipe clamp $81.00 FC20CW (3) 20 foot mechanical control switches / cable weight $ FR20 (3) 20 foot mercury control switches / pipe clamp $93.00 FR20CW (3) 20 foot mercury control switches / cable weight $ FC30 (3) 30 foot mechanical control switches / pipe clamp $96.00 FC30CW (3) 30 foot mechanical control switches / cable weight $ FR30 (3) 30 foot mercury control switches / pipe clamp $ FR30CW (3) 30 foot mercury control switches / cable weight $ FC50 (3) 50 foot mechanical control switches / pipe clamp $ FC50CW (3) 50 foot mechanical control switches / cable weight $ FR50 (3) 50 foot mercury control switches / pipe clamp $ FR50CW (3) 50 foot mercury control switches / cable weight $ GR Gray Enclosure (black enclosure is standard) $0 HD1 Heavy Duty 1: Increase breakers & wire gauge to allow $21.00 HD2 Heavy Duty 2: Increase breakers & wire gauge to allow $32.00 HS Heat Sensor Terminals $21.00 HTR Anti-Condensation Heater $ IB IBTD Digital Interface Board Time Dosing DIB $ $ LA Lightning Arrestor $95.00 OL## Pump Overload - specify amperage after OL (Example: OL02 = 2 amp pump, OL20 = 20 amp pump) $ SF Seal Failure Indicator Light $48.00 X Auxiliary Alarm and Redundant Off Circuitry (control switch not included) $48.00 *Contact factory for capacitor circuitry details Suggested List Price - Pricing Effective 02/04/19
9 CONTROL PANELS **RK SERIES PANELS Single phase, duplex capacitor start/run demand dose or timed dose float controlled system for pump control and system monitoring. **RK SERIES SINGLE PHASE DUPLEX CAPACITOR START/RUN FLOAT PANELS RANGE CIRCUIT BREAKERS RKDF230CBG 0-12 NEMA 4X Motor & Alarm, Capacitor Circuitry* $1, RKDF230ACBG 0-12 NEMA 4X Motor, Control & Alarm, Capacitor Circuitry* $1, AMB Amber Beacon (red beacon is standard) $0 DC DCTD Digital Display Center Time Dosing DDC $ $ FC20 (4) 20 foot mechanical control switches / pipe clamp $ FC20CW (4) 20 foot mechanical control switches / cable weight $ FR20 (4) 20 foot mercury control switches / pipe clamp $ FR20CW (4) 20 foot mercury control switches / cable weight $ FC30 (4) 30 foot mechanical control switches / pipe clamp $ FC30CW (4) 30 foot mechanical control switches / cable weight $ FR30 (4) 30 foot mercury control switches / pipe clamp $ FR30CW (4) 30 foot mercury control switches / cable weight $ FC50 (4) 50 foot mechanical control switches / pipe clamp $ FC50CW (4) 50 foot mechanical control switches / cable weight $ FR50 (4) 50 foot mercury control switches / pipe clamp $ FR50CW (4) 50 foot mercury control switches / cable weight $ GR Gray Enclosure (black enclosure is standard) $0 HD1 Heavy Duty 1: Increase breakers & wire gauge to allow $32.00 HD2 Heavy Duty 2: Increase breakers & wire gauge to allow $42.00 HS Heat Sensor Terminals $42.00 HTR Anti-Condensation Heater $ IB IBTD Digital Interface Board Time Dosing DIB $ $ LA Lightning Arrestor $95.00 OL## Pump Overload - specify amperage after OL (Example: OL02 = 2 amp pump, OL20 = 20 amp pump) $ SF Seal Failure Indicator Lights $96.00 X Auxiliary Alarm and Redundant Off Circuitry (control switch not included) $48.00 *Contact factory for capacitor circuitry details Suggested List Price - Pricing Effective 02/04/19 7
10 CONTROL PANELS **RK SERIES DISPLAYS The RK Series displays are currently available in two versions - the Digital Display Center (DDC), and the Digital Interface Board (DIB). The DDC display utilizes a (4) four character LED display screen while the DIB incorporates a two line, 16 character display screen providing a more complete read out for the user. **DIGITAL DISPLAY CENTER (DDC) - 4 CHARACTER READ OUT PART # MODEL# DESCRIPTION DDCS Simplex Elapsed Time Meter & Cycle Counter $ DDCSTD Simplex Timed Dosing w/time Meter & Counter $ DDCD Duplex Elapsed Time Meter & Cycle Counter $ DDCDTD Duplex Timed Dosing w/time Meter & Counter $ **DIGITAL INTERFACE BOARD (DIB) - 32 CHARACTER READ OUT PART # MODEL# DESCRIPTION DIBS Simplex Elapsed Time Meter & Cycle Counter $ DIBD Duplex Elapsed Time Meter & Cycle Counter $ DIBSTD Simplex Time Dosing w/elapsed Time Meter & Cycle Counter $ DIBDTD Duplex Time Dosing w/elapsed Time Meter & Cycle Counter $ **FUSION ECONOMY PANELS Single phase, simplex demand dose float controlled system for pump control and system monitoring. MAX **ECONOMY FUSION SIMPLEX FLOAT PANELS FC20 (3) 20 foot mechanical control switches / pipe clamp $81.00 FC20CW (3) 20 foot mechanical control switches / cable weight $ FR20 (3) 20 foot mercury control switches / pipe clamp $93.00 FR20CW (3) 20 foot mercury control switches / cable weight $ FC30 (3) 30 foot mechanical control switches / pipe clamp $96.00 FC30CW (3) 30 foot mechanical control switches / cable weight $ FR30 (3) 30 foot mercury control switches / pipe clamp $ FR30CW (3) 30 foot mercury control switches / cable weight $ FC50 (3) 50 foot mechanical control switches / pipe clamp $ FC50CW (3) 50 foot mechanical control switches / cable weight $ FR50 (3) 50 foot mercury control switches / pipe clamp $ FR50CW (3) 50 foot mercury control switches / cable weight $ HD1 Heavy Duty 1: Increase breakers & wire gauge to allow $21.00 HD2 Heavy Duty 2: Increase breakers & wire gauge to allow $32.00 X Auxiliary Alarm Contacts $21.00 Example with 20 foot Mechanical Floats and Heavy Duty 2: EFS115CB-FC20-HD2 = $ List CIRCUIT BREAKERS EFS NEMA 4X None $ EFS115CB 12 NEMA 4X Motor & Control $ EFS115ACB 12 NEMA 4X Motor, Control & Alarm $ EFS NEMA 4X None $ EFS230CB 12 NEMA 4X Motor & Control $ EFS230ACB 12 NEMA 4X Motor, Control & Alarm $ Suggested List Price - Pricing Effective 02/04/19
11 CONTROL PANELS **FUSION PANELS Single phase, simplex demand dose or timed dose float controlled system for pump control and system monitoring. MAX **FUSION SINGLE PHASE SIMPLEX FLOAT PANELS CIRCUIT BREAKERS FS115CB 12 NEMA 4X Motor & Control $ FS115ACB 12 NEMA 4X Motor, Control & Alarm $ FS230CB 12 NEMA 4X Motor & Control $ FS230ACB 12 NEMA 4X Motor, Control & Alarm $ FS230CBG 12 NEMA 4X Motor & Control, Capacitor Circuitry* $1, FS230ACBG 12 NEMA 4 X Motor, Control & Alarm, Capacitor Circuitry* $1, AMB Amber Beacon (red beacon is standard) $0 AR Manual Alarm Reset $95.00 EC Elapsed Time Meter and Cycle Counter $ FC20 (3) 20 foot mechanical control switches / pipe clamp $81.00 FC20CW (3) 20 foot mechanical control switches / cable weight $ FR20 (3) 20 foot mercury control switches / pipe clamp $93.00 FR20CW (3) 20 foot mercury control switches / cable weight $ FC30 (3) 30 foot mechanical control switches / pipe clamp $96.00 FC30CW (3) 30 foot mechanical control switches / cable weight $ FR30 (3) 30 foot mercury control switches / pipe clamp $ FR30CW (3) 30 foot mercury control switches / cable weight $ FC50 (3) 50 foot mechanical control switches / pipe clamp $ FC50CW (3) 50 foot mechanical control switches / cable weight $ FR50 (3) 50 foot mercury control switches / pipe clamp $ FR50CW (3) 50 foot mercury control switches / cable weight $ HD1 Heavy Duty 1: Increase breakers & wire gauge to allow $21.00 HD2 Heavy Duty 2: Increase breakers & wire gauge to allow $32.00 HS Heat Sensor Terminals $21.00 HTR Anti-Condensation Heater $ LA Lightning Arrestor $95.00 LL Low Level Alarm (control switch not included) $42.00 OL## Pump Overload - specify amperage after OL (Example: OL02 = 2 amp pump, OL20 = 20 amp pump) $ SF Seal Failure Indicator Light $48.00 TD Time Dosing Operation $ X Auxiliary Alarm Contacts $21.00 Example with 20 foot Mechanical Floats and 11 amp Overload: FS115CB-FC20-OL11 = $ List *Contact factory for capacitor circuitry details Suggested List Price - Pricing Effective 02/04/19 9
12 CONTROL PANELS **FUSION PANELS Single phase, duplex demand dose float controlled system for pump control and system monitoring. MAX **FUSION SINGLE PHASE DUPLEX FLOAT PANELS CIRCUIT BREAKERS Example with 20 foot Mechanical Floats, Heavy Duty 1, and 15 amp Overloads: FD115ACB-FC20-HD1-OL15 = $1, List FD115CB 12 NEMA 4X Motor & Control $1, FD115ACB 12 NEMA 4X Motor, Control & Alarm $1, FD230CB 12 NEMA 4X Motor & Control $1, FD230ACB 12 NEMA 4X Motor, Control & Alarm $1, AMB Amber Beacon (red beacon is standard) $0 AR Manual Alarm Reset $95.00 EC Elapsed Time Meter and Cycle Counter $ FC20 (4) 20 foot mechanical control switches / pipe clamp $ FC20CW (4) 20 foot mechanical control switches / cable weight $ FR20 (4) 20 foot mercury control switches / pipe clamp $ FR20CW (4) 20 foot mercury control switches / cable weight $ FC30 (4) 30 foot mechanical control switches / pipe clamp $ FC30CW (4) 30 foot mechanical control switches / cable weight $ FR30 (4) 30 foot mercury control switches / pipe clamp $ FR30CW (4) 30 foot mercury control switches / cable weight $ FC50 (4) 50 foot mechanical control switches / pipe clamp $ FC50CW (4) 50 foot mechanical control switches / cable weight $ FR50 (4) 50 foot mercury control switches / pipe clamp $ FR50CW (4) 50 foot mercury control switches / cable weight $ HD1 Heavy Duty 1: Increase breakers & wire gauge to allow $32.00 HD2 Heavy Duty 2: Increase breakers & wire gauge to allow $42.00 HS Heat Sensor Terminals $42.00 HTR Anti-Condensation Heater $ LA Lightning Arrestor $95.00 LL Low Level Alarm (control switch not included) $42.00 OL## Pump Overload - specify amperage after OL (Example: OL02 = 2 amp pump, OL20 = 20 amp pump) $ SF Seal Failure Indicator Lights $96.00 X Auxiliary Alarm Contacts $ Suggested List Price - Pricing Effective 02/04/19
13 CONTROL PANELS **POWER ZONE PANELS Single phase, simplex demand dose or timed dose float controlled system for pump control and system monitoring. D Dual Power - Separates incoming power to Pump & Alarm/Control 115V - $ V - $27.00 FC15 (2) 15 foot mechanical float switches - one pump switch and one control switch $59.00 HO MAX **POWER ZONE JR. SINGLE PHASE SIMPLEX FLOAT PANELS MATERIAL Includes a 2 hub to mount enclosure on a 2 conduit & an outlet that allows for plug-in installation of pump. (115V - 15 amp max.) PZJRF NEMA 4X Polycarbonate $ PZJRF NEMA 4X Polycarbonate $ Example with all options selected: PZJRF115-D-FC15-HO = $ List MAX **POWER ZONE SINGLE PHASE SIMPLEX FLOAT PANELS CIRCUIT BREAKERS $21.00 PZSF115CB 16 NEMA 4X Motor & Control $ PZSF115ACB 16 NEMA 4X Motor, Control & Alarm $ PZSF230CB 16 NEMA 4X Motor & Control $ PZSF230ACB 16 NEMA 4X Motor, Control & Alarm $ Power Zone Simplex Transmitter 4-20mA PZST115CB 16 NEMA 4x Motor & Control $ PZST115ACB 16 NEMA 4x Motor, Control & Alarm $ PZST230CB 16 NEMA 4x Motor & Control $ PZST230ACB 16 NEMA 4x Motor, Control & Alarm $ OPTIONS DESCRIPTION FLOAT PANEL LIST ADDER TRANSMITTER PANEL LIST ADDER FC20 20 foot (6.1m) mechanical control switches / pipe clamp (3) PZSF - $81.00 (2) PZST - $54.00 FC20CW 20 foot (6.1m) mechanical control switches / cable weight (3) PZSF - $ (2) PZST - $68.00 FR20 20 foot (6.1m) mercury control switches / pipe clamp (3) PZSF - $93.00 (2) PZST - $62.00 FR20CW 20 foot (6.1m) mercury control switches / cable weight (3) PZSF - $ (2) PZST - $76.00 FC30 30 foot (9.1m) mechanical control switches / pipe clamp (3) PZSF - $96.00 (2) PZST - $64.00 FC30CW 30 foot (9.1m) mechanical control switches / cable weight (3) PZSF - $ (2) PZST - $78.00 FR30 30 foot (9.1m) mercury control switches / pipe clamp (3) PZSF - $ (2) PZST - $72.00 FR30CW 30 foot (9.1m) mercury control switches / cable weight (3) PZSF - $ (2) PZST - $86.00 FC50 50 foot (15.2m) mechanical control switches / pipe clamp (3) PZSF - $ (2) PZST - $96.00 FC50CW 50 foot (15.2m) mechanical control switches / cable weight (3) PZSF - $ (2) PZST - $ FR50 50 foot (15.2m) mercury control switches / pipe clamp (3) PZSF - $ (2) PZST - $ FR50CW 50 foot (15.2m) mercury control switches / cable weight (3) PZSF - $ (2) PZST - $ HD Heavy Duty - Increases breakers and wire gauge to allow $21.00 PED Poly Pedestal with access door $ TS25 (1) SLX 16.7 ftwc with 25 foot cable (backup floats recommended, add float code option)* $ TS50 (1) SLX 16.7 ftwc with 50 foot cable (backup floats recommended, add float code option)* $ X Auxiliary Alarm & Redundant Off Circuitry (control switch not included) $48.00 Example with 20 foot Mechanical Floats, and Pedestal: PZSF115CB-FC20-PED = $ List *Only available for PZST panel models Suggested List Price - Pricing Effective 02/04/19 11
14 CONTROL PANELS **POWER ZONE PANELS Single phase, duplex demand dose float controlled system for pump control and system monitoring. MAX **POWER ZONE SINGLE PHASE DUPLEX FLOAT PANELS CIRCUIT BREAKERS PZDF115CB 16 NEMA 4X Motor & Control $ PZDF115ACB 16 NEMA 4X Motor, Control & Alarm $ PZDF230CB 16 NEMA 4X Motor & Control $ PZDF230ACB 16 NEMA 4X Motor, Control & Alarm $ Power Zone Duplex Transmitter 4-20mA PZDT115CB 16 NEMA 4x Motor & Control $ PZDT115ACB 16 NEMA 4x Motor, Control & Alarm $ PZDT230CB 16 NEMA 4x Motor & Control $ PZDT230ACB 16 NEMA 4x Motor, Control & Alarm $ OPTIONS DESCRIPTION FLOAT PANEL LIST ADDER TRANSMITTER PANEL LIST ADDER FC20 20 foot (6.1m) mechanical control switches / pipe clamp (4) PZDF - $ (2) PZDT - $54.00 FC20CW 20 foot (6.1m) mechanical control switches / cable weight (4) PZDF - $ (2) PZDT - $68.00 FR20 20 foot (6.1m) mercury control switches / pipe clamp (4) PZDF - $ (2) PZDT - $62.00 FR20CW 20 foot (6.1m) mercury control switches / cable weight (4) PZDF - $ (2) PZDT - $76.00 FC30 30 foot (9.1m) mechanical control switches / pipe clamp (4) PZDF - $ (2) PZDT - $64.00 FC30CW 30 foot (9.1m) mechanical control switches / cable weight (4) PZDF - $ (2) PZDT - $78.00 FR30 30 foot (9.1m) mercury control switches / pipe clamp (4) PZDF - $ (2) PZDT - $72.00 FR30CW 30 foot (9.1m) mercury control switches / cable weight (4) PZDF - $ (2) PZDT - $86.00 FC50 50 foot (15.2m) mechanical control switches / pipe clamp (4) PZDF - $ (2) PZDT - $96.00 FC50CW 50 foot (15.2m) mechanical control switches / cable weight (4) PZDF - $ (2) PZDT - $ FR50 50 foot (15.2m) mercury control switches / pipe clamp (4) PZDF - $ (2) PZDT - $ FR50CW 50 foot (15.2m) mercury control switches / cable weight (4) PZDF - $ (2) PZDT - $ HD Heavy Duty - Increases breakers and wire gauge to allow $32.00 PED Poly Pedestal with access door $ TS25 (1) SLX 16.7 ftwc with 25 foot cable (backup floats recommended, add float code option)* $ TS50 (1) SLX 16.7 ftwc with 50 foot cable (backup floats recommended, add float code option)* $ X Auxiliary Alarm & Redundant Off Circuitry (control switch not included) $48.00 Example with 20 foot Mechanical Floats and Pedestal: PZDF115CB-FC20-PED = $1, List *Only available for PZDT panel models Suggested List Price - Pricing Effective 02/04/19
15 **MINUTEMAN LEVEL ALERT PEDESTAL PANELS Pedestal mounted plugger control panel with high water alarm. PART # CSMM CSMMP CONTROL PANELS **MINUTEMAN LEVEL ALERT PANELS DESCRIPTION Nema 4X Alarm with LED Alarm Light, outlet for piggyback float installation & 9V battery back-up. Includes a 15ft alarm float switch and enclosure mounting feet. Piggyback pump switch & pedestal not included. Nema 4X Pedestal Mounted Alarm with LED Alarm Light, outlet for piggyback float installation & 9V battery back-up. Includes a 15ft alarm float switch and rubber grommet to seal incoming wires. Piggyback pump switch not included. $ $ Volt $27.00 D GF Dual Power - Separate incoming power to Pump & Alarm/Control (1) 15ft Piggyback pump switch Example Volt with a Piggyback float: CSMMP-230-GF = $ V $ V $ V $ V $64.00 NF No Float included - Deducts Standard 15ft Alarm Float (-$27.00) T Terminal block incoming power connection $21.00 **H 2 OIL ALARM SYSTEM Provides pump control and alarm notification of potentially threatening water and oil levels in simplex pumping applications H2Oil Alarm System $1, H2Oil Alarm System with CS1200 Alarm $1, Suggested List Price - Pricing Effective 02/04/19 13
16 CONTROL PANELS **VIP-331 PANELS Three phase, three voltages, one panel for duplex pump station applications. MAX VIP-331 CONTROL PANEL DESCRIPTION NEMA 4X 208/240/480-3 VIP-331 Control Panel, Stainless Steel $4, NEMA 4X 208/240/480-3 VIP-331 Control Panel, Fiberglass $3, NEMA 4X 208/240/480-3 VIP-331 Control Panel, Stainless Steel, Intrinsically Safe $4, NEMA 4X 208/240/480-3 VIP-331 Control Panel, Fiberglass, Intrinsically Safe $4, * Overload module $ * Overload module $ * Overload module $ Surge arrestor $ Pedestal Option - Consult Factory * Two overload modules required for panel operation. **VIP-XR PANEL Three phase duplex industrial grade control panel with continuous level monitoring featuring the Atlas 4-XR Controller. **VIP-XR PANEL VIP-XR Control Panel $4, * Overload Module, $ * Overload Module, $ *Two overload modules required for panel operation Suggested List Price - Pricing Effective 02/04/19
17 **CS2004E ALARM SYSTEMS NEMA 4X outdoor alarm with alarm light and test-normal-silence toggle switch. Includes a 15ft float switch and a 6 power cord with 3/8 seal-tight cord connectors. $ NF No Float Included - Deduct Standard 15ft alarm float (-$33.00) H Exchanges the cord grips and power cord for a 2 hub adapter to mount over 2 electrical conduit. $0 Example: CS2004E-H = $ List **CS NEMA 4X outdoor alarm with LED alarm lights and touch to test/touch to silence circuitry. Includes a 15ft float switch and a 6ft power cord with 3/8 seal-tight cord connectors. $ NF No Float Included - Deduct Standard 15ft alarm float (-$33.00) H Exchanges the cord grips and power cord for a 2 hub adapter to mount over 2 electrical conduit. $0 X Provides one set of Aux. Alarm Contacts $33.00 Example: CS2004-H-X = $ List **CS1200 WIFI CS1200 WiFi, 120V, High, with 15 ft. Control Switch (PCNO) $ CS1200 WiFi, 120V, Low, with 15 ft. Control Switch (PCNC) $ CS1200 WiFi, 120V, No Float $ **CS CS1200, NEMA 1 non-metallic indoor alarm with auto-reset battery backup feature. Includes a 15 foot float switch and a 6ft power cord. $ CS1200-AUX, includes auxiliary contacts (CSA certified only unit) $ CS1200-NF, no float included $91.10 Note: Low level float and longer float lengths available. **CS CS1000, NEMA 1 indoor alarm with manual reset feature. Includes a 15 foot float switch and a 6ft power cord. $ CS1000-NF, no float included $ CS1000-SPKT, includes splice kit $ Note: Low level float and longer float lengths available Suggested List Price - Pricing Effective 02/04/19 15
18 PUMP SWITCHES **FLOAT SWITCHES Due to the many variations of pump floats, please consult your local Representative or the factory for our full offering of floats. **MEDIUM DUTY - WIDE ANGLE MECHANICAL PUMP SWITCHES PART # DESCRIPTION PSD1WP PSU1WP $ PSDWOP PSUWOP $ PSD1WP PSU1WP $ PSDWOP PSUWOP $ PSD1WP PSU1WP $ PSDWOP PSUWOP $80.75 PS = Pump Switch D = Pump Down U = Pump Up 1 = 125VAC WP = With Plug WOP = With Out Plug NOTE: Descriptions are grouped by cable length measured in feet (15, 20, 30). MOUNTING CLAMP is standard. PACKAGING: Boxed - Standard Additional configurations available. Please call for details. **HEAVY DUTY - WIDE ANGLE MECHANICAL PUMP SWITCHES PART # DESCRIPTION PSPD1WP PSPU1WP $ PSPD2WP PSPU2WP $ PSPDWOP PSPUWOP $ PSPD1WP PSPU1WP $ PSPD2WP PSPU2WP $ PSPDWOP PSPUWOP $ PSPD1WP PSPU1WP $ PSPD2WP PSPU2WP $ PSPDWOP PSPUWOP $ PS = Pump Switch D = Pump Down U = Pump Up 1 = 120VAC 2 = 230VAC WP = With Plug WOP = With Out Plug NOTE: Descriptions are grouped by cable length measured in feet (15, 20, 30). MOUNTING CLAMP is standard. PACKAGING: Boxed - Standard Additional configurations available. Please call for details. **MEDIUM DUTY - WIDE ANGLE MERCURY PUMP SWITCHES PART # DESCRIPTION PSVD1WP PSVU1WP $ PSVD2WP PSVU2WP $ PSVDWOP PSVUWOP $ PSVD1WP PSVU1WP $ PSVD2WP PSVU2WP $ PSVDWOP PSVUWOP $ PSVD1WP PSVU1WP $ PSVD2WP PSVU2WP $ PSVDWOP PSVUWOP $ PS = Pump Switch V = Mercury D = Pump Down U = Pump Up 1 = 120VAC 2 = 230VAC WP = With Plug WOP = With Out Plug NOTE: Descriptions are grouped by cable length measured in feet (15, 20, 30). MOUNTING CLAMP is standard. PACKAGING: Boxed - Standard Additional configurations available. Please call for details Suggested List Price - Pricing Effective 02/04/19
19 PUMP SWITCHES **MEDIUM DUTY - WIDE ANGLE MINI MERCURY PUMP SWITCHES PART # DESCRIPTION PSJVD1WP PSJVU1WP $ PSJVD2WP PSJVU2WP $ PSJVDWOP PSJVUWOP $ PSJVD1WP PSJVU1WP $ PSJVD2WP PSJVU2WP $ PSJVDWOP PSJVUWOP $ PSJVD1WP PSJVU1WP $ PSJVD2WP PSJVU2WP $ PSJVDWOP PSJVUWOP $93.80 PS = Pump Switch JV = Junior Mercury D = Pump Down U = Pump Up 1 = 120VAC 2 = 230VAC WP = With Plug WOP = With Out Plug NOTE: Descriptions are grouped by cable length measured in feet (15, 20, 30). MOUNTING CLAMP is standard. PACKAGING: Boxed - Standard Additional configurations available. Please call for details. PS = Pump Switch LS = Limited Space D = Pump Down 1 = 120VAC WP = With Plug MOUNTING BRACKET and HOSE CLAMP are standard. PACKAGING: Boxed - Standard Additional configurations available. Please call for details. **MEDIUM DUTY - LIMITED SPACE PUMP SWITCH PSLSD1WP $ PSLSD1WP $84.93 **MEDIUM DUTY - WIDE ANGLE DUAL PUMP SWITCHES PART # DESCRIPTION PSDFD1WP PSDFU1WP $ PSDFD2WP PSDFU2WP $ PSDFD1WOP PSDFU1WOP $ PSDFD2WOP PSDFU2WOP $ PSDFD1WP PSDFU1WP $ PSDFD2WP PSDFU2WP $ PSDFD1WOP PSDFU1WOP $ PSDFD2WOP PSDFU2WOP $ PSDFD1WP PSDFU1WP $ PSDFD2WP PSDFU2WP $ PSDFD1WOP PSDFU1WOP $ PSDFD2WOP PSDFU2WOP $ PS = Pump Switch DF = Dual Float D = Pump Down U = Pump Up 1 = 120VAC 2 = 230VAC WP = With Plug WOP = With Out Plug NOTE: Descriptions are grouped by cable length measured in feet (15, 20, 30). MOUNTING CLAMP is standard. PACKAGING: Boxed - Standard Additional configurations available. Please call for details. **HIGH TEMPERATURE PUMP SWITCHES ft. HTM with plug, 120V $ ft. HTM with plug, 230V $ ft. HTM without plug $ ft. HTM with plug, 120V $ ft. HTM with plug, 230V $ ft. HTM without plug $ Suggested List Price - Pricing Effective 02/04/19 17
20 CONTROL SWITCHES **SPEED-E CONNECT 3-Port Float Switch Connection System The Speed-E Connect 3-port system features a wiring manifold with quick release float switch ports that allows for easy maintenance and replacement of 1-3 floats. The single 6-conductor manifold cable features Red-Blue-Yellow wire pairs that match R-B-Y imprints on the manifold housing for easy wiring and float identification. A rubber boot is provided with each float switch for extra protection. Sealing plugs are available for unused ports. Rated for short term submersion in water. **SPEED-E CONNECT 3-PORT MANIFOLD SPEED-E CONNECT, 3-Port, 25FT, W/BRACKET $ SPEED-E CONNECT, 3-Port, 50FT, W/BRACKET $ SPEED-E CONNECT, 3-Port, 100FT, W/BRACKET $ **SPEED-E CONNECT 4-Port Float Switch Connection System The Speed-E Connect 4-port system features a wiring manifold with quick release float switch ports that allows for easy maintenance and replacement of 1-4 floats. The single 8-conductor manifold cable features Red-Blue-Yellow-White wire pairs that match colored caps on the manifold housing for easy wiring and float identification. A rubber boot is provided with each float switch for extra protection. Sealing plugs are available for unused ports. Rated for short term submersion in water. **SPEED-E CONNECT 4-PORT MANIFOLD SPEED-E CONNECT, 4-Port, 25FT, W/BRACKET $ SPEED-E CONNECT, 4-Port, 50FT, W/BRACKET $ SPEED-E CONNECT, 4-Port, 100FT, W/BRACKET $ **SPEED-E CONNECT CONTROL SWITCHES - NARROW ANGLE NORMALLY OPEN NORMALLY CLOSED PART # DESCRIPTION MAPNPCNOSC MAPNPCNCSC $ MAPNPCNOSC MAPNPCNCSC $ MAPNPCNOSC MAPNPCNCSC $ MAPNCWNOSC MAPNCWNCSC $ MAPNCWNOSC MAPNCWNCSC $ MAPNCWNOSC MAPNCWNCSC $68.20 **SPEED-E CONNECT CONTROL SWITCHES - WIDE ANGLE NORMALLY OPEN NORMALLY CLOSED PART # DESCRIPTION MAPWPCNOSC MAPWPCNCSC $ MAPWPCNOSC MAPWPCNCSC $ MAPWPCNOSC MAPWPCNCSC $ MAPWCWNOSC MAPWCWNCSC $ MAPWCWNOSC MAPWCWNCSC $ MAPWCWNOSC MAPWCWNCSC $68.20 **SPEED-E CONNECT CONTROL DUTY EXTRA LARGE VERSIONS NORMALLY OPEN NORMALLY CLOSED PART # DESCRIPTION MGMNOSC MGMNCSC $ MGMNOSC MGMNCSC $ MGMNOSC MGMNCSC $ **SPEED-E CONNECT OPTIONS SPEED-E CONNECT SEALING PLUG (INCLUDES RUBBER BOOT) $11.00 The Speed-E Connect 3-port and 4-port systems include: manifold and mounting bracket. Ordered separately: sealing plug with rubber boot and Speed-E Connect low current mechanically-activated float switches rated at 125 VAC, 0.160mA to 1A for low current applications. N = Narrow Angle W = Wide Angle PC = Pipe Clamp CW = Cable Weight NO = Normally Open NC = Normally Closed SC = Speed-E Connect NOTE: One sealing plug must be ordered for each unused port. Do not install manifold with open port(s) Suggested List Price - Pricing Effective 02/04/19
21 CONTROL SWITCHES **CONTROL SWITCHES Due to the many variations of control switches, please consult your local Representative or the factory for our full offering of floats. **CONTROL DUTY - NARROW EXTRA LARGE MECHANICAL CONTROL SWITCHES MGM, 25 ft. bag $ MGM, 50 ft. bag $ MGM, 75 ft. bag $ MGM, 100 ft. bag $ Internally weighted. Can be wired to work in either pump down (normally open) or pump up (normally closed) applications. PACKAGING: Bagged - Standard **CONTROL DUTY - NARROW ANGLE MECHANICAL CONTROL SWITCHES PART # DESCRIPTION CSPCNO CSPCNC $ CSWENO CSWENC $ CSPCNO CSPCNC $ CSWENO CSWENC $ CSPCNO CSPCNC $ CSWENO CSWENC $65.72 CS = Control Switch PC = Pipe Clamp WE = Weighted Externally NO = Normally Open NC = Normally Closed NOTE: Descriptions are grouped by cable length measured in feet (15, 20, 30). PACKAGING: Bagged - Standard. Additional configurations available. Please call for details. **CONTROL DUTY - NARROW ANGLE LOW CURRENT MECHANICAL CONTROL SWITCHES PART # DESCRIPTION CSLCPCNO CSLCPCNC $ CSLCWENO CSLCWENC $ CSLCPCNO CSLCPCNC $ CSLCWENO CSLCWENC $ CSLCPCNO CSLCPCNC $ CSLCWENO CSLCWENC $68.60 CS = Control Switch LC = Low Current PC = Pipe Clamp WE = Weighted Externally NO = Normally Open NC = Normally Closed NOTE: Descriptions are grouped by cable length measured in feet (15, 20, 30). PACKAGING: Bagged - Standard Additional configurations available. Please call for details Suggested List Price - Pricing Effective 02/04/19 19
22 CONTROL SWITCHES **CONTROL DUTY - NARROW ANGLE MERCURY CONTROL SWITCHES CSVPCNO $ CSVPCNC $ CSVPCNO $ CSVPCNC $ CSVPCNO $ CSVPCNC $72.93 CS = Control Switch V = Mercury PC = Pipe Clamp NO = Normally Open NC = Normally Closed MOUNTING CLAMP is standard. PACKAGING: Bagged - Standard Additional configurations available. Please call for details. **CONTROL DUTY - NARROW ANGLE MINI MERCURY CONTROL SWITCHES CSMVNO $ CSMVNC $ CSMVNO $ CSMVNC $ CSMVNO $ CSMVNC $68.45 CS = Control Switch MV = Mini Mercury NO = Normally Open NC = Normally Closed MOUNTING CLAMP is standard. PACKAGING: Bagged - Standard Additional configurations available. Please call for details Suggested List Price - Pricing Effective 02/04/19
23 ACCESSORIES **FLOAT ACCESSORIES Pipe Mount Stainless Clamp for Tethering Floats $ Iron Weight Assembly $ Cable Weight Assembly $ Stainless Steel Float Bracket with 3 Black Cord Snubbers $ Stainless Steel float Bracket with 4 Black Cord Snubbers $59.52 **CONTROL DUTY - VERTICAL REED SWITCH CSRS1 $93.34 CS = Control Switch RS = Reed Switch 1 = 120VAC **PEDESTALS **SLX TRANSMITTER SLX, 16.7 ftwc, 25 ft. cable $ SLX, 16.7 ftwc, 50 ft. cable $ SLX, 33.4 ftwc, 25 ft. cable $ SLX, 33.4 ftwc, 50 ft. cable $ hook bracket (optional) $ Poly Pedestal $ Suggested List Price - Pricing Effective 02/04/19 21
24 F 12/ SJE, Inc. All Rights Reserved. CSI CONTROLS is a trademark of SJE, Inc. Toll Free: Phone:
Alarm Systems Alarm Bot CS2004E CS CS CS H2Oil Alarm System...12
TABLE OF CONTENTS Control Panels Page # Power Zone Jr. Simplex Float Panel...4 Power Zone Simplex Float Panel...4 Power Zone Duplex Float Panel...4 Fusion Economy...5 Fusion Simplex Float Panel...5 Fusion
More informationWe ve Got Panels Under Control.
We ve Got Panels Under Control Table of Contents CONTROL PANELS Page # RK Series Single Phase Simplex... A.1 RK Series Single Phase Duplex... A.3 RK Series Three Phase Simplex... A.5 RK Series Three Phase
More informationPRODUCT PRICE BOOK January 1, 2019
PRODUCT PRICE BOOK January 1, 2019 Control Panels Alarm Systems Float Switches Accessories Follow us on: www.sjerhombus.com ORDERING INFORMATION To assist us in delivering the exact product you want, please
More informationPRODUCT PRICE BOOK September 4, 2018
PRODUCT PRICE BOOK September 4, 2018 Control Panels Alarm Systems Float Switches Accessories Follow us on: www.sjerhombus.com ORDERING INFORMATION To assist us in delivering the exact product you want,
More informationPRODUCT PRICE BOOK JUNE 4, 2018
PRODUCT PRICE BOOK JUNE 4, 2018 Control Panels Alarm Systems Float Switches Accessories Follow us on: www.sjerhombus.com ORDERING INFORMATION To assist us in delivering the exact product you want, please
More information2018 PRICING. alderonind.com STANDARD PRODUCTS
2018 PRICING alderonind.com STANDARD PRODUCTS Terms & Conditions PURCHASE ORDERS Preferred via email: orders@alderonind.com If e-mail is not available, send via fax: 218.483.3036 SHIPPING INFORMATION MINIMUMS:
More informationQUICK SHIP Products. Available for Same/Next Day Shipment at NO ADDITIONAL CHARGE!
QUICK SHIP Products Available for Same/Next Day Shipment at NO ADDITIONAL CHARGE! www.sjerhombus.com NEED PRODUCTS IN A HURRY? DON T WORRY! SJE-Rhombus is committed to being the best in the industry. In
More informationTHE MOST COMPLETE LINE OF SYSTEM ALARMS FLOAT SWITCHES ON-SITE ACCESSORIES CONTROL PANELS 24 HOUR SHIPPING ON ALL CATALOG ORDERS!
THE MOST COMPLETE LINE OF SYSTEM ALARMS FLOAT SWITCHES ON-SITE ACCESSORIES CONTROL PANELS 24 HOUR ON ALL CATALOG ORDERS! TABLE OF CONTENTS SYSTEM MONITORING DEVICES Plug-In Pedestal Alarm System... 4 High
More informationproduct brochure Sump, Effluent and Sewage Controls
product brochure Sump, Effluent and Sewage Controls Control Panels, Alarms and Float Switches From the Controls Leader You Trust www.sjerhombus.com EZ Series This line of innovative, affordable control
More informationSerious Products for Serious Contractors! User s Manual
Serious Products for Serious Contractors! User s Manual Pressure Systems Table of Contents About RK Series Pressure Systems...p 3 Pressure System Installation Instructions...p 4-8 Additional Parts the
More informationCustom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2
The Custom Controls Solution Provider Hydromatic has a reputation for providing dependable submersible pumps for wastewater lift stations and has continually raised the bar for quality products and customer
More information2 SJE-Rhombus...The Name You Trust Above: Simplex - Below: Duplex Above: Simplex - Below: Duplex
EZ Series Control Panels This line of innovative, affordable control panels is designed to make on-site installations easier. EZ Series control panels combine circuit board technology and easy operation
More informationANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.
ANCHOR BOLT DETAIL Heavy Flat Washer Heavy Hex Nut UNC Th'd Mounting Flange Of Equipment To Be Mounted C B A D Non-Shrink Grout. Poured In Place, After Equipment Setting. Heavy Flat Washer Heavy Hex Nut
More informationBeacon 410A Gas Monitor Operator s Manual
Beacon 410A Gas Monitor Operator s Manual Part Number: 71-0397 Revision: F Released: 12/5/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be
More informationGRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES
GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES GRUNDFOS CONTROL PANELS Simplex Panel Duplex Panel Standard Features LISTING: Underwriters Laboratories, UL 508. RATINGS: Model S1 rated up to 120 VAC, 1 Hp,
More informationCheck It Panel. 1 Phase Simplex Demand Dose Operation, Maintenance & Installation Manual. Introduction. Safety Guidelines
Introduction Before proceeding with the installation or operation of the control panel read all instructions thoroughly, as well as comply with all Federal, State and Local Codes, Regulations and Practices.
More informationTECHNICAL BROCHURE BCALARM R4. Indoor and Outdoor Panels and Accessories
TECHNICAL BROCHURE BCALARM R4 Indoor and Outdoor Panels and Accessories FEATURES Indoor and Outdoor alarm panels for sump, effluent and wastewater systems as well as test panel for troubleshooting. Use
More informationPUMP / CONTROL PANEL SWITCHES TECHNICAL BROCHURE BCPFS R10
PUMP / CONTROL PANEL SWITCHES TECHNICAL BROCHURE BCPFS R10 TERMS TO KNOW Pump Switches are used to directly control the operation of a pump. They are normally wide-angle switches which means they operate
More informationSIMPLEX WEATHERPROOF CONTROL PANELS
TECHNICAL BROCHURE BCP3 R10 FEATURES Rugged, NEMA 4X construction withstands even the most severe weather con ditions and prevents corrosion. Solid-state control board displays float status for ease of
More informationThree Phase Simplex. Installation (937) Installation Instructions and Operation/Troubleshooting Manual. Installation of Floats.
Three Phase Simplex Installation Instructions and Operation/Troubleshooting Manual This control panel must be installed and serviced by a licensed electrician in accordance with the National Electric Code
More informationGasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08
GasScanner 4C Four Channel Monitor Operator s Manual MINT-0280-XX Rev. A 02/25/08 Product Warranty Matheson Tri-Gas., warrants gas alarm equipment sold by us to be free from defects in materials, workmanship,
More informationCITY OF MEXICO BEACH REQUEST FOR QUOTES: LIFT STATION PANELS REPLACEMENT
CITY OF MEXICO BEACH REQUEST FOR QUOTES: LIFT STATION PANELS REPLACEMENT The City of Mexico Beach is requesting quotes for replacement of 18 lift station control panels. The lift stations range from 2
More informationEG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G
E SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF DATE: 11/13/06 2/1/07 1 Copyright, E, Inc. E 1. ENERAL...4 1.1 Scope Of Work... 4 1.2 Codes and Standards... 4 2. PRODUCTS...5
More information631RF Amp Power Supply
631RF - 1.5 Amp Power Supply Modular Access Control Power Supply Field Selectable 12VDC or 24VDC Output - Standard Dual 12VDC and 24VDC Output - Optional Quality, Performance and Versatility The SDC 631RF
More informationInstaller Friendly Series In-Site. Installation Instructions and Operation/Troubleshooting Manual. Installation. Mounting the Control Panel
Installer Friendly Series In-Site SJE-Rhombus Type IFI Installation Instructions and Operation/Troubleshooting Manual This control panel must be installed and serviced by a licensed electrician in accordance
More informationSTATION MODEL: KPCG21-24x48 PUMP MODEL: KEEN KPCG21 VOLTAGE: 230 PHASE: 1 TANK DIMENSIONS: 24 DIAMETER X 48 DEEP
STATION MODEL: KPCG21-24x48 PUMP MODEL: KEEN KPCG21 VOLTAGE: 230 PHASE: 1 TANK DIMENSIONS: 24 DIAMETER X 48 DEEP PUMP Grinder Pumps KPCG-21 1HP Dual Seal, High Performance Progressive Cavity Grinder Pump,
More informationBeacon 800 Gas Monitor Operator s Manual
Beacon 800 Gas Monitor Operator s Manual Part Number: 71-0037RK Revision: F Released: 4/18/17 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by us to be
More informationBeacon 110 Gas Monitor Operator s Manual
Beacon 110 Gas Monitor Operator s Manual Part Number: 71-0110RK Revision: H Released: 12/5/17 RKI Instruments, Inc. www.rkiinstruments.com Product Warranty RKI Instruments, Inc., warrants gas alarm equipment
More informationPOINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS
POINT OBSTRUCTION CONTROLLER Compliances: FAA Advisory Circular 70/7460-1L ICAO Annex 14, Volume I, Chapter 6 The controller provides the control and monitoring functions for an LED red obstruction lighting
More informationPS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option
Installation PS6 SERIES Power Supplies PS6 SERIES Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option Installation and Specifications Manual ISDPS6_SERIES 08121590 PCN15016 R05/15GR
More informationPiggyback Mechanical Float Switch. Piggyback Vertical Mechanical Float Switch. Piggyback Diaphragm Switch. Accessories
Piggyback Mechanical Float Switch Piggyback Vertical Mechanical Float Switch Residential sewage waste transfer RFSN-6, RFSN-9 and RFSN-10 any manual pump, up through 3/4 convert any manual pump, up hp
More informationELECTRICAL DH VERSUS DR SERIES OPTIONS LISTED IN THE ONLINE AND PRINT CATALOG FOR ENVIRONMENT ONE DH071/DR071 STATIONS. WHICH DO YOU SELECT?
ELECTRICAL DH VERSUS DR SERIES OPTIONS LISTED IN THE ONLINE AND PRINT CATALOG FOR ENVIRONMENT ONE DH071/DR071 STATIONS. WHICH DO YOU SELECT? The DH071 is the hardwired or wired model where a cable connects
More informationGasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A
GasScanner 1C Single Channel Monitor Operator s Manual MINT-0278-XX Rev A Product Warranty Matheson Tri-Gas, Inc., warrants gas alarm equipment sold by us to be free from defects in materials, workmanship,
More informationBeacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08
Beacon 200 Gas Monitor Operator s Manual Part Number: 71-2102RK Released: 6/6/08 Table of Contents Chapter 1: Introduction.................................................3 Overview.............................................................3
More informationSJE-Rhombus Type IFS w/c-level Sensor Installation Instructions and Operation/Troubleshooting Manual
Installer Friendly Series SJE-Rhombus Type IFS w/c-level Sensor Installation Instructions and Operation/Troubleshooting Manual This control panel must be installed and serviced by a licensed electrician
More informationCommercial and Light Industrial Fire Alarm Control Panel
FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel Features Easily expandable. All new plug-in board design Two supervised audible circuits Lamp and system trouble circuit test Ground
More informationLaboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls
Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls Specification General The Powerex Laboratory Scroll Enclosed Air Compressor System is designed to provide clean, dry air for
More informationRDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:
RDM LOCK G-1 1400 Series Electromagnetic Lock The patented 1400 Series Electromagnetic Lock is universal for all types of applications, including outdoor use. The innovative design will reduce installation
More informationSingle Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3
Single Phase Simplex SXL21=3, SXL24=3, SXH21=3, and SXH24=3 Manufactured by SJE-Rhombus Installation Instructions and Operation/Troubleshooting Manual 7000 Apple Tree Avenue Bergen, New York 14416 Phone:
More informationElectric Pumps. Introduction. W4100, W4200 & W4300 Condensate Pumps. Typical Condensate Pump Features
Electric Pumps Introduction W4100, W4200 & W4300 Condensate Pumps Watson McDaniel s Condensate Return and Boiler Feed Pumps are equipped with Cast Iron bodies and Bronze Impellers. The pump receiver tanks
More informationFIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL
FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL THE GAMEWELL COMPANY PN: 71981 60 PLEASANT STREET ISSUE A ASHLAND, MA 01721 3/22/2001 This page intentionally blank ii
More informationUnilift KP, AP, SU/SV, SE & EF
GRUNDFOS PRODUCT GUIDE Unilift KP, AP, SU/SV, SE & EF Sump, Sewage, Effluent and Utility Pumps 60 Hz LSEPG001 7-05 new.indd 1 9/27/2005, 9:36:00 AM Contents Mission General data 5 Performance range 5 Product
More informationChromaStar. Comfort. Infra-Red Radiant Heaters. Description. Portable. Applications. Fixed Overhead. 1.5 to 13.5 kw. 5,118 to 46,062 BTU/Hr
1.5 kw 4.5 kw 4.5 kw 2.0 kw 1.5 to 13.5 kw 5,118 to 46,062 BTU/Hr 6.0 kw 120, 208, 240, 277, 480, and 600 Volts 6.0 kw Single or 3 Phase - Most Models Field Convertible 13.5 kw Fixed Overhead - Convertible
More informationPublic Safety DAS Annunciator Panel
Public Safety DAS Annunciator Panel 120 VAC Models: 1221-A, 1221-B, 1221-C Revision D 91117 48 VDC Models: 1221-A-48, 1221-B-48, 1221-C-48 24 VDC Models: 1221A-24, 1221-B-24, 1221-C-24 CAUTION: (Read This
More informationGRUNDFOS DATA BOOKLET SLC, DLC. Pump controllers
GRUNDFOS DATA BOOKLET Pump controllers Table of contents. Product introduction 3 3 Features and benefits 3 Applications 3 2. Identification Type key 3. Technical data 5. Construction 6 SLC cabinet for
More informationControl Panel with Across The Line Starters
ECO SMART Station ATL Control Panel with Across The Line Starters The ECO SMART STATION ATL is a pre-engineered duplex control panel designed specifically for municipal lift station applications. Housed
More informationSAFETY INFORMATION AND WARNINGS
This manual refers to the Model SST-3 control panel manufactured since October 31, 2013, which uses a universal (100 277 VAC; 50/60 Hz) power supply. Older units use a voltage-specific power supply and
More informationPO Box 827 Hawley, MN (218) Fax (218)
Introduction Before proceeding with the installation or operation of the Oil Alert System, read all instructions thoroughly, as well as complying with all Federal, State and Local codes, Regulations and
More informationGasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08
GasScanner 8C Eight Channel Monitor Operator s Manual MINT-0281-XX Rev. A 01/29/08 Product Warranty Matheson Tri-Gas, Inc., warrants gas alarm equipment sold by us to be free from defects in materials,
More informationSpecification/ Data Sheet
Specification/ Data Sheet TRITON RP Agent Release Control Panel FEATURES Agent Release Control Panel designed specifically for suppression release operation with: Four initiating device circuits (IDCs)
More informationFireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel
PROTECTOWIRE FireSystems Features Easily expandable Two supervised audible circuits Lamp and system trouble circuit test Ground fault detection Initiating device circuit (IDC) alarm test Monitors up to
More informationNU2 Smart Power Supply (SPS) Manual
GENERAL The Smart Power Supply (SPS) is an innovative Quad Output, field programmable power supply. Each of the four outputs can provide four Amps for a total of sixteen Amps in either 12VDC or 24VDC.
More informationArrow Hart hospital grade self-test GFCI receptacles
Description 2-pole, 3-wire grounding 15A, 125V/AC; 20A, 125V/AC NEMA 5-15, 5-20 Design features Performs periodic self-tests to ensure integrity of GFCI protection. Meets and exceeds 10 ka short circuit
More informationACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F
II 1400-2 ACSI 1406-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F INSTALLATION Transformer Model BE31763001 by Basler Electric, Transformer Model 2010028 by Galaxy
More informationPLSRR Heat Trace Cable Data Sheet
PLSRR Heat Trace Cable Data Sheet PLSRR is self-regulating heat cable that can be used for roof / gutter heating pipe tracing. The cable features a flexible, UV-stabilized thermoplastic elastomer overjacket
More informationThe system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.
FireCell Radio Hub Fully addressable Wireless activation Third party approved (EN54) 2-way radio communication Loop powered Diagnostics port Range in excess of 150 metres Overview The model FCX-500-001
More informationINSTRUCTION MANUAL MODEL LDE 740. (Revised July 8, 2017)
PNEUMERCATOR Liquid Level Control Systems Multi Tank Monitoring System INSTRUCTION MANUAL MODEL LDE 740 (Revised July 8, 2017) COPYRIGHT 2017 PNEUMERCATOR CO. 1785 EXPRESSWAY DRIVE NORTH, HAUPPAUGE, NY
More informationBeacon 200 Gas Monitor Operator s Manual
Beacon 200 Gas Monitor Operator s Manual Part Number: 71-0059RK Revision: J Released: 1/31/18 www.rkiinstruments.com Product Warranty RKI Instruments, Inc. warrants gas alarm equipment sold by us to be
More informationElevator Sump Kits and Components
A4-SEE1 TECHNICAL BROCHURE BCPELSPKT R8 A1SEEWATER Oil Smart Switch A1SEE Panel Series Liquid Smart Switch Standard Effluent Pump The Oil Smart Switch with panel or alarm, when combined with a pump, allows
More informationLiquid Level Alarms & Controls
16/06/17 E14 Low Voltage High Water Alarm Protects your home from potential water flood damage by placing anywhere a water leak may exist Loud 85 db buzzer sounds for up to 18 hours Intermittent chirp
More informationRELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:
RELEASE DEVICES MADE IN THE U.S.A. RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: 7300-1418:100 GENERAL DESCRIPTION: S/N: The "WPS" World Power Series, Time Delay Release
More informationPump Station Appliance
GE Intelligent Platforms Pump Station Appliance Installation and User Manual GFK-2848A January 2014 Warnings, Cautions and Notes as Used in this Publication Warning Warning notices are used in this publication
More informationTECHNICAL BROCHURE BCPSDWWP R2 SIMPLEX/DUPLEX WASTEWATER DISCONNECT STYLE PANELS
TECHNICAL BROCHURE BCPSDWWP R SIMPLEX/DUPLEX WASTEWATER ONNECT STYLE PANELS PANEL FEATURES Oversize enclosure to accommodate all options. One main disconnect through-the-door with door interlock, prevents
More informationPipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual
MANUAL Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual Model FPT 130 Single Point Freeze Protection Heat Trace Control Table of Contents SCFP-CO-F130 Overview... 3 Installation...
More informationTraceNet ECM Series Control System
TraceNet ECM Series Control System ECM Operating Guide Thermon Manufacturing Company TraceNet is a registered trademark of Thermon Manufacturing Company. ECM Operating Guide 2014, 2015 Thermon Manufacturing
More informationR E C T I F I E R I N V E R T E R C O N V E R T E R SB7
SCR Battery Charger Product Specifications Description The is RIC Electronics premiere SCR battery charger/rectifier. The provides power to critical DC loads through a wide range of outputs and is engineered
More informationT M. User Manual. MarinaGuard. Ground Fault Monitoring Panel For Marina Shore Power
T M User Manual MarinaGuard Ground Fault Monitoring Panel For Marina Shore Power NAE1095810 / 03.2013 T M Bender Inc. USA: 700 Fox Chase Coatesville, PA 19320 Toll-Free: 800-356-4266 Phone: 610-383-9200
More informationRack Mount Series Installation Guide
Rack Mount Series Installation Guide Models Include: Maximal1RHV Maximal1RV - 12VDC @ 4 amp or 24VDC @ 3 amp. - 12VDC @ 4 amp or 24VDC @ 3 amp. - Eight (8) Fuse Protected Outputs. - Sixteen (16) Fuse Protected
More informationSump Pumps Instruction Manual & Safety Warnings
Important Safety Instructions SAVE THESE INSTRUCTIONS. This manual contains important SAFETY WARNINGS and OPERATING INSTRUCTIONS. You will need to refer to it before attempting any installation or maintenance.
More informationTOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design
TOTAL SOLUTIONS Liquid Level Control Product Guide MATELEC innovative by design Liquid Level Control Contents Dual Pump Controllers Section 1 The Range Common Features Operating Data Control Logic Setup
More informationModel A2100 Series Annunciator
Seekirk Model A2100 Series Annunciator Applications: For usage within transformers, switchgear, breakers and/or within any processing equipment or control room applications either attended or unattended
More informationCool IR. Model C104 - Cooling System. Instruction Manual
Cool IR Model C104 - Cooling System Instruction Manual February 26, 2015 Research, Inc. USA Ph: 952.949-9009 Fax: 952.949-9559 tsdsales@researchinc.com www.researchinc.com Table of Contents List of Figures...
More informationSingle Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual
We manage heat MANUAL Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual 1850 N Sheridan Street South Bend, Indiana 46628 (574) 233-1202 or (800) 234-4239
More informationAPS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES
APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES POWER SUPPLY AND BATTERY CHARGER AC AND DC STATUS INDICATORS ENOUGH POWER TO SUPPORT UP TO 3 MAGLOCKS OR ELECTRIC STRIKES PLUS REQUIRED
More informationCHAPTER 20 SERVICE EQUIPMENT
SERVICE EQUIPMENT CHAPTER 20 SERVICE EQUIPMENT Service equipment includes service cabinets and the equipment and materials necessary for installation. 20.1 Signal Service Cabinet For MnDOT traffic control
More informationRemote NAC Power Supply D7038
Operation and Installation Guide Remote NAC Power Supply D7038 D7038 REMOTE NAC POWER SUPPLY Page 2 2005 Bosch Security Systems Contents Contents 1.0 Overview...5 1.1 Module Control...5 1.1.1 Option Bus
More informationMission Critical. Fuel Supply Systems
Fuel Supply Systems Insight Onsite Fuel Supply Systems Page 2 Simplex Mission Critical Fuel Supply Systems are comprehensive, integrated, project-matched fuel management systems for diesel and turbine
More information/9308 External Battery Chargers Installation Instructions
4081-9306/9308 External Battery Chargers Installation Instructions Introduction This publication describes the installation procedure for an External Battery Charger used with the 4100U or 4100ES System.
More informationNGC-40 Advanced Heat-Tracing Control System
NGC-40 Advanced Heat-Tracing Control System Local configuration and monitoring with Raychem Touch 1500 touch screen display Heat-tracing system NGC-40 system Remote configuration and monitoring with Raychem
More informationIntegra Family. Operations Manual. Models: Integra TX SS, Integra HD, Integra DS, Integra DS LA, Integra UHS, Machine Name: Serial Number:
Integra Family GREEN CIRCLE CERCLE VERT Operations Manual Models: Integra TX SS, Integra HD, Integra DS, Integra DS LA, Integra UHS, Machine Name: Date of Purchase: Serial Number: Service Center Number:
More informationIsolated Power Systems Equipment
2 Isolated Power Systems Equipment For Hospitals and Critical Care Areas Brochure NAE2091010 / 10.2012 BENDER Isolated Power System Equipment Isolated Power System with Line Isolation Monitor for hospitals
More informationOperating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm
Operating & Maintenance Manual Alert-4 Ethernet LCD Master Alarm w w w. a m i c o. c o m Contents User Responsibility 4 Introduction 4 Features 5 Description of the Alarm 5 Shipment Details 5 The Alarm
More informationIon Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm
Page 1 of 8 General Overview Thank you for purchasing an Ion Genesis controller. Take the time to read the instructions carefully before using this appliance. We strongly recommend that you keep this instruction
More informationEMERGENCY & SPECIALTY VEHICLES PANELS & PRODUCTS CATALOG
EMERGENCY & SPECIALTY VEHICLES PANELS & PRODUCTS CATALOG MARINE SYSTEMS ENGINEERING & INTEGRATION 1 Index Alarm panels 90-9600 Alarm Panel 3 Custom Door Alarm Panels 4 79-10012 Low Voltage Alarm Panel
More informationINVITATION TO TENDER ITT NO. PS KILLARNEY COMMUNITY CENTRE ENERGY UPGRADE ADDENDUM NO. 2
FINANCE, RISK AND BUSINESS PLANNING GROUP Supply Chain Management November 4, 2015 INVITATION TO TENDER ITT NO. PS20151058 KILLARNEY COMMUNITY CENTRE ENERGY UPGRADE ADDENDUM NO. 2 RE: Insert attached Section
More informationModel LTN-3R Outdoor Rated Uninterruptible Power System Single Phase
Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase General Specification 550 VA/Watts 1300 VA/Watts 1.0 GENERAL This specification defines the electrical and mechanical characteristics
More informationUpright Refrigerators. Blood Bank. TrueBlue. Reliability & Support. i.series Horizon Series
Upright Refrigerators Blood Bank TrueBlue. Reliability & Support Medical-grade refrigerators designed specifically for blood bank applications. Helmer high-performance blood bank refrigerators are a result
More informationTECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.
September 29, 1997 Firecycle III 433 a 1. PRODUCT NAME VIKING Model E-1 Manufactured 1997 Present 2. MANUFACTURED FOR THE VIKING CORPORATION 210 N Industrial Park Road Hastings, Michigan 49058, U.S.A.
More informationTrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description
TrueCom Building Communications Systems 5115-Series 5115-9001, -9002 Area of Rescue Communications System Description The Simplex 5115-9001 and -9002 Area of Rescue Communications System provides buildings
More informationTYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM
2 Line, 16 Characters/row LCD Display Temperature Input Range -50 C to +500 C -58 F to + 932 F Enclosure NEMA Type 4X Current Rating 30A max (resistive load only) Ambient Temperature -40 C to + 40 C -40
More informationAT10.1 Series Microprocessor-Controlled Float Battery Charger (single phase input)
STANDARD SAMPLE SPECIFICATION AT10.1 Series Microprocessor-Controlled Float Battery Charger (single phase input) A battery charger shall be furnished in accordance with the following specification: 1.0
More informationSeries. Access Power Controllers. Installation Guide
Series Access Power Controllers Installation Guide Models Include: Maxim11 - Power Supply 1: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Power Supply 2: 12VDC @ 3.5 amp or 24VDC @ 2.7 amp. - Sixteen (16) fuse
More informationEXPLODED VIEWS & PARTS LISTS
561 DOOR VIEW Ref. Part No. Description Ref. Part No. Description 1 6200720 Screw, #8-18 x 1/2 PH Truss HD 2 420040 Standard Handle End Cap Replacement Components 4200700 Extended Handle End Cap Replacement
More information/ How To Order
84-800 / 85-800 How To Order SERIES 84 = 1.0A continuous (powers and controls 1 EExER device with signal output for 1 operator) 85 = 2.0A continuous (powers and controls EExER device for 1 pair of doors
More informationAF/GF dual-purpose receptacles
Eaton Wiring Devices OBC AF/GF dual-purpose receptacles AF/GF dual-purpose receptacles Arc fault and ground fault protection in one device In Stock July 2016! Eaton Wiring Devices OBC AF/GF dual-purpose
More informationEngineered Basins Affordable, effective pressure sewer system Rocky, hilly, wet and flat topography Dependable, reliable and cost effective
brands you trust. Engineered Basins Affordable, effective pressure sewer system Rocky, hilly, wet and flat topography Dependable, reliable and cost effective ENGINEERED BASIN SERIES Barnes Pressure Sewer
More informationLORAIN CIP 4890/48120 DC Power System
DC Power for Business-Critical Continuity Key Features Compact flexibility provides rectifiers, distribution, and controller in one shelf Constant power delivers more current at lower voltages to meet
More informationBarnes Oil Sensor Switch
Elevator sump basins Transformer vaults Leachate wells Garages Barnes BOSS Barnes Oil Sensor Switch Model BOSS BOSS PLUS RPM 3450 3450 Oil Water Switch Cord Length 10 10 Enclosure Rated Options Automatic
More informationKT-100 Door Controller
WARNING: This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully
More informationCentro-Matic Automated Lubrication Systems System Controls
Selecting the right controls for your automated lubrication system is one of the last steps in the design process. Several different models may be chosen to control power-operated pumps, depending on the