SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Size: px
Start display at page:

Download "SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005"

Transcription

1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 TUV SUD CANADA 1 11 Gordon Collins Dr. Gormley, Ontario, L0H 1G0, CANADA William (Mac) Elliott Phone: ELECTRICAL Valid To: June 30, 2019 Certificate Number: In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory at the location listed above, as well as the satellite laboratory location listed below, to perform the following EMC and Product Safety tests: Tests: Test Method(s) 2 : Emissions Radiated (3 meter site up to 40 GHz) (10 meter site up to 1 GHz) & Conducted (Unintentional Radiators) 47 CFR FCC Part 15, Subpart B (using ANSI C63.4:2014); 47 CFR FCC Part 18 (using FCC MP-5:1986); ANSI C63.4:2009; ICES-001; ICES-002; ICES-003; EN ; CISPR 11 3 ; AS/NZS CISPR 11 3 ; CISPR 12; EN 55012; AS/NZS CISPR 12; CISPR 13; EN 55013; AS/NZS CISPR 13; CISPR 14-1 (excluding measurements of clicks); EN (excluding measurements of clicks); AS/NZS CISPR 14.1 (excluding measurements of clicks); EN 55015; CISPR 15; AS/NZS CISPR 15; EN 55032; CISPR 32; AS/NZS CISPR 32; EN 55022; CISPR 22; CAN/CSA-CEI/IEC CISPR 22; AS/NZS CISPR 22; 3GPP TS v (section 8); CNS (up to 6 GHz); CAN/CSA C108.6-M91; VCCI-V3/10.4 (up to 6 GHz), V4; KN 11; KN 13; KN 14-1; KN 15; KN 22; KN 32; EN (excluding measurements of clicks); EN (sections C1.2.2 and C1.2.3) Current Harmonics 3 IEC ; EN ; AS/NZS Flicker and Fluctuations 3 IEC ; EN ; AS/NZS (A2LA Cert. No ) Revised 09/18/2017 Page 1 of 11

2 Immunity Electrostatic Discharge 3 IEC ; EN ; KN ; IEC ; IEEE C Radiated Immunity IEC ; EN ; KN ; IEC ; IEEE C Electrical Fast IEC ; EN ; KN ; IEC Transient/Burst 3 Surge Immunity 3 IEC ; EN ; KN ; IEEE C ; IEEE C62.41; IEEE C62.45; IEC (level 3 and 4) Conducted Immunity 3 IEC ; EN ; KN ; IEC Power Frequency Magnetic IEC ; EN ; KN Field Immunity 3 Impulse Magnetic Field IEC ; EN ; KN Damped Oscillatory Magnetic Field Immunity Voltage Dips, Short Interruptions, and Line Voltage Variations 3 IEC ; EN IEC ; EN ; KN ; IEC ; EN ; IEC ; EN Ring Wave Immunity IEC ; EN Harmonics / Interharmonics IEC ; EN Immunity to Conducted, Common Mode Disturbances in the Frequency Range 0 Hz to 150 khz IEC ; EN Oscillatory Wave Immunity IEC ; EN ; IEC Frequency Variations IEC ; EN Generic and Product Specific EMC Standards Laboratory Equipment (Immunity) IEC ; EN ; IEC/EN ; IEC/EN (A2LA Cert. No ) Revised 09/18/2017 Page 2 of 11

3 Generic and Product Specific EMC Standards (cont.) Medical Equipment IEC ; EN ; KN ; NBR IEC ; JIS T :2012 (Second,Third, and Fourth editions) Alarm Systems (Immunity) EN ; IEC ; EN ; IEC ; EN ; IEC UPS / Audio / Lighting IEC ; EN ; IEC ; EN ; IEC ; EN ; IEC61547; EN 61547; KN Household Appliances CISPR 14-2: A1:2001; EN A1: A2:2008; KN 14-2 ITE/Telecom (Immunity) CISPR 24; EN 55024; AS/NZS CISPR 24; ETSI EN ; KN 24 Residential, Commercial and Light Industrial Generic Industrial Generic Railway Uninterruptible Power Supply (Emissions) Telecontrol Equipment and Systems (Emissions) Cable Networks/Radio Signals (Emissions and Immunity Relays Product family standard for lifts, escalators, and moving walks (Immunity) IEC ; EN ; IEC ; EN ; KN ; KN ; AS/NZS ; AS/NZS IEC ; EN ; IEC ; EN ; KN ; KN ; AS/NZS ; AS/NZS EN ; EN ; EN ; EN ; EN ; EN ; IEC ; IEC ; IEC ; IEC ; IEC ; IEC IEC ; EN ; AS ; KN IEC ; EN EN ; IEC EN EN (A2LA Cert. No ) Revised 09/18/2017 Page 3 of 11

4 Generic and Product Specific EMC Standards (cont.) Vehicles, Boats, and Internal Combustion Engines EN 55025; CISPR 25; AS/NZS CISPR 25 Automatic Electrical Controls IEC (sections 23 and 26); EN (sections 23 and 26) Machine Tools EN ; EN Automotive Component EMC ISO ; ISO Agricultural/Forestry Machinery Multimedia Equipment Radio Tests / Intentional Radiators (up to 40 GHz) (excluding SAR and DFS) Photo-biological Safety of LED Lamps and Lasers Military EMC/EMI ISO (excluding section 6.8) KN 35 (excluding xdsl-specific requirements) 47 CFR, FCC Part 15, Subparts C and E (using ANSI C63.4:2014 and ANSI C63.10:2013); 47 CFR, FCC Part 22 3 (using ANSI/TIA-603-D; TIA-102.CAAA-D); 47 CFR, FCC Part 24 3 (using ANSI/TIA-603-D; TIA-102.CAAA-D); 47 CFR, FCC Part 25 3 (using ANSI/TIA-603-D; TIA-102.CAAA-D); 47 CFR, FCC Part 27 3 (using ANSI/TIA-603-D; TIA-102.CAAA-D); 47 CFR, FCC Part 90 3 (using ANSI/TIA-603-D; TIA-102.CAAA-D); 47 CFR, FCC Part 96 3 (using ANSI/TIA-603-D; TIA-102.CAAA-D); ETSI EN ; ETSI EN ; ETSI EN ; ETSI EN ; ETSI EN ; ETSI EN , -2, -3, -4, -5, -6, -7, -8, -9, -10, -11, -13, -14, -15, -16, -17, -22, -27, & -31; ETSI EN ; ETSI EN ; ETSI EN V6.2.1 (sections and 4.2.3); RSS ; RSS ; RSS ; RSS ; RSS-197; RSS-GEN; RSS-210; RSS-247; RSS-310; AS/NZS 4268; LP0001; LP0002; KN , -2, -3, -5, -6, -7, -9, -13, -15, -17, -18, -20, -24, -26, -27, & -32 IEC 62471; IEC ; IEC ; IEC ; IEC MIL-STD-461C (using methods in MIL-STD-462); MIL-STD-462 (CS01, CS02, CS06, RS02); MIL-STD 461G (A2LA Cert. No ) Revised 09/18/2017 Page 4 of 11

5 Product Safety 3 (Excluding: Ionizing radiation, high vacuum devices, flammability/fire tests, softening temperature, vibration, implosion, dust, microbiological test for bioseals & sonic and ultrasonic pressure) UL/CSA IEC/EN ; UL 1598/C22.2 No. 250; C22.1 No. 250; UL/CSA IEC/EN ; CSA C22.2 No ; CSA C22.2 No ; CSA C22.2 No ; UL/CSA IEC/EN ; UL/CSA/AAMI IEC ; UL/CSA IEC/EN (All Inclusive); UL 22; UL 73; UL 197; UL 291; UL 294; UL 506; UL 508, 508A, 508C; UL 745; UL 778; UL 813; UL 859; UL 873; UL 935; UL 1012; UL 1017; UL 1028; UL 1088; UL 1097; UL 1236; UL 1310; UL 1411; UL 1419; UL 1431; UL 1492; UL 1561; UL 1563; UL 1573; UL 1574; UL 1585; UL 1598; UL 1778; UL 1838; UL 1993; UL 1995; UL/CSA IEC/EN ; UL/CSA IEC/EN (All Inclusive); UL/CSA IEC/EN 61010A-2-010; UL/CSA IEC/EN 61010A-2-041; UL/CSA IEC/EN 61010A-2-051; UL/CSA IEC/EN 61010B-1; UL/CSA/IEC/EN (including all collateral standards); UL/CSA/IEC/EN ; IEC 62304; IEC 62366; IEC/ISO , CSA (including all particular standards); UL/CSA IEC ; IEC/EN (All Inclusive); IEC/EN ; IEC/EN ; IEC/EN ; EN ; IEC/EN ; IEC/EN 60529; IEC/EN On the following products or types of products: Appliances, Industrial, Scientific, Medical (ISM), Information Technology Equipment (ITE), Vehicles, Boats, & Internal Combustion Engine Driven Devices Radio Disturbance, Intentional and Unintentional Radiators. (A2LA Cert. No ) Revised 09/18/2017 Page 5 of 11

6 Testing Activities Performed in Support of FCC Declaration of Conformity and Certification in Accordance with 47 Code of Federal Regulations and FCC KDB , Appendix A, Table A.1 * : Rule Subpart/Technology Test Method Maximum Frequency Unintentional Radiators Part 15B ANSI C63.4: MHz Industrial, Scientific, and Medical Equipment Part 18 FCC MP-5 (February 1986) MHz Intentional Radiators Part 15C ANSI C63.10: MHz * Accreditation does not imply acceptance to the FCC equipment authorization program. Please see the FCC website ( for a listing of FCC approved laboratories. 1 This accreditation covers testing performed at the main laboratory listed above, and the satellite laboratory listed below: (A2LA Cert. No ) Revised 09/18/2017 Page 6 of 11

7 Emissions TUV SUD CANADA 2972 Joseph-A-Bombardier Laval, Quebec, H7P 6E3, CANADA Phone: Radiated (3Meter site only) & Conducted (Unintentional Radiators) 47 CFR FCC Part 15, Subpart B (using ANSI C63.4:2014); 47 CFR FCC Part 18 (using FCC MP-5:1986); ANSI C63.4:2009; ICES-001; ICES-003; EN ; CISPR 11 3 ; AS/NZS CISPR 11 3 ; CISPR 14-1 (excluding measurements of clicks); EN (excluding measurements of clicks); AS/NZS CISPR 14.1 (excluding measurements of clicks); CISPR 13; EN 55013; AS/NZS CISPR 13; EN 55015; CISPR 15; AS/NZS CISPR 15; EN 55032; CISPR 32; AS/NZS CISPR 32; EN 55022; CISPR 22; CAN/CSA-CEI/IEC CISPR 22; AS/NZS CISPR 22; 3GPP TS v (section 8); CNS (up to 6 GHz); CAN/CSA C108.6-M91; KN 11; KN 13; KN 14-1; KN 15; KN 22; KN 32; EN (excluding measurements of clicks); EN (sections C1.2.2 and C1.2.3) Current Harmonics 3 IEC ; EN ; AS/NZS Flicker and Fluctuations 3 IEC ; EN ; AS/NZS Immunity Electrostatic Discharge 3 IEC ; EN ; KN ; IEC ; IEEE C Radiated Immunity IEC ; EN ; KN ; IEC ; IEEE C Electrical Fast IEC ; EN ; KN ; IEC Transient/Burst 3 Surge Immunity 3 IEC ; EN ; KN ; IEEE C ; IEEE C62.41; IEEE C62.45; IEC (level 3 and 4) Conducted Immunity 3 IEC ; EN ; KN ; IEC (A2LA Cert. No ) Revised 09/18/2017 Page 7 of 11

8 Immunity (cont.) Power Frequency Magnetic IEC ; EN ; KN Field Immunity 3 Impulse Magnetic Field IEC ; EN ; KN Voltage Dips, Short Interruptions, and Line Voltage Variations 3 IEC ; EN ; KN ; IEC ; EN ; IEC ; EN Damped Osillatory Waves IEC ; EN Frequency Variations IEC ; EN Harmonics/Interharmonics IEC ; EN Generic and Product Specific EMC Standards Laboratory Equipment (Immunity) Medical Equipment IEC ; EN ; IEC/EN ; IEC/EN IEC ; EN ; KN ; NBR IEC ; JIS T :2012 (Second, Third, and Fourth editions) Alarm Systems (Immunity) EN ; IEC ; EN ; IEC ; EN ; IEC Automatic Electrical Controls IEC (sections 23 and 26); EN (sections 23 and 26) UPS/Audio/Lighting IEC ; EN ; IEC ; EN ; IEC ; EN ; IEC 61547; EN 61547; KN Household Appliances CISPR 14-2: A1:2001; EN A1: A2:2008; KN 14-2 ITE/Telecom (Immunity) CISPR 24; EN 55024; AS/NZS CISPR 24; ETSI EN ; KN 24 Residential, Commercial and Light Industrial Generic IEC ; EN ; IEC ; EN ; KN ; KN ; AS/NZS ; AS/NZS (A2LA Cert. No ) Revised 09/18/2017 Page 8 of 11

9 Generic and Product Specific EMC Standards (Cont d) Industrial Generic Railway Uninterruptible Power Supply (Emissions) Telecontrol Equipment and Systems (Emissions) Cable Networks/Radio Signals (Emissions and Immunity Relays Product Family Standard for Lifts, Escalators and Moving Walks (Immunity) Vehicles, Boats, and Internal Combustion Engines IEC ; EN ; IEC ; EN ; KN ; KN ; AS/NZS ; AS/NZS EN ; EN ; EN ; EN ; EN ; EN ; IEC ; IEC ; IEC ; IEC ; IEC ; IEC IEC/EN ; AS ; KN IEC ; EN EN ; IEC EN EN EN 55025; CISPR 25; AS/NZS CISPR 25 Automotive Component EMC ISO ; ISO Agricultural / Forestry Machinery Multimedia Equipment ISO (excluding section 6.8) KN 35 (excluding xdsl-specific requirements) Military EMC/EMI MIL-STD-461C (using methods in MIL-STD-462); MIL-STD-462 (CS01, CS02, CS06, RS02); MIL-STD 461G (A2LA Cert. No ) Revised 09/18/2017 Page 9 of 11

10 Radio Tests / Intentional Radiators (up to 40 GHz) (excluding SAR and DFS) Product Safety 3 (Excluding: UV exposure and resistance to UV exposure, ionizing radiation, microwave radiation, high vacuum devices, sound pressure level, flammability/fire tests, softening temperature, vibration, implosion, dust, microbiological test for bioseals, & sonic and ultrasonic pressure) 47 CFR, FCC Part 15, Subparts C and E (using ANSI C63.4:2014 and ANSI C63.10:2013); ANSI C63.4:2009; 47 CFR, FCC Part 22 3 (using ANSI/TIA-603-D; TIA-102.CAAA-D); 47 CFR, FCC Part 24 3 (using ANSI/TIA-603-D; TIA-102.CAAA-D); 47 CFR, FCC Part 25 3 (using ANSI/TIA-603-D; TIA-102.CAAA-D); 47 CFR, FCC Part 27 3 (using ANSI/TIA-603-D; TIA-102.CAAA-D); 47 CFR, FCC Part 90 3 (using ANSI/TIA-603-D; TIA-102.CAAA-D); 47 CFR, FCC Part 96 3 (using ANSI/TIA-603-D; TIA-102.CAAA-D); ETSI EN ; ETSI EN ; ETSI EN ; ETSI EN ; ETSI EN , -2, -3, -4, -5, -6, -7, -8, -9, -10, -11, -13, -14, -15, -16, -17, -22, -27, & -31; ETSI EN V6.2.1 (sections and 4.2.3); RSS ; RSS ; RSS ; RSS ; RSS-197; RSS-GEN; RSS-210; RSS-247; RSS-310; AS/NZS 4268; LP0001; LP0002; KN , -2, -3, -5, -6, -7, -9, -13, -15, -17, -18, -20, -24, -26, -27, & -32 UL/CSA IEC/EN ; UL 1598/C22.2 No. 250; C22.1 No. 250; UL/CSA IEC/EN ; CSA C22.2 No ; CSA C22.2 No ; CSA C22.2 No ; UL/CSA IEC/EN ; UL/CSA/AAMI IEC ; UL/CSA IEC/EN (All Inclusive); UL 22; UL 73; UL 197; UL 291; UL 294; UL 506; UL 508, 508A, 508C; UL 745; UL 778; UL 813; UL 859; UL 873; UL 935; UL 1012; UL 1017; UL 1028; UL 1088; UL 1097; UL 1236; UL 1310; UL 1411; UL 1419; UL 1431; UL 1492; UL 1561; UL 1563; UL 1573; UL 1574; UL 1585; UL 1598; UL 1778; UL 1838; UL 1993; UL 1995; UL/CSA IEC/EN ; UL/CSA IEC/EN (All Inclusive); UL/CSA IEC/EN 61010A-2-010; UL/CSA IEC/EN 61010A-2-041; UL/CSA IEC/EN 61010A-2-051; UL/CSA IEC/EN 61010B-1; UL/CSA/IEC/EN (including all collateral standards); UL/CSA/IEC/EN ; IEC/EN 62304; IEC/EN 62366; IEC/ISO , CSA (including all particular standards); UL/CSA IEC/EN ; IEC/EN (All Inclusive); IEC/EN ; IEC/EN ; IEC/EN ; EN ; IEC/EN 60529; IEC/EN ; IEC/EN (A2LA Cert. No ) Revised 09/18/2017 Page 10 of 11

11 On the following products or types of products: Appliances, Industrial, Scientific, Medical (ISM), Information Technology Equipment (ITE), Intentional and Unintentional Radiators. 2 The laboratory is only accredited for testing activities outlined within the test methods listed above. Reference to any other activity within these standards, such as risk management or risk assessment, does not fall within the laboratory s accredited capabilities. 3 This laboratory meets A2LA R104 General Requirements: Accreditation of Field Testing and Field Calibration Laboratories for these tests. The field testing scope excludes tests where the contribution of uncertainty due to the field site itself is required by the standard to be included in the measurement uncertainty calculation requirements. Testing Activities Performed in Support of FCC Declaration of Conformity and Certification in Accordance with 47 Code of Federal Regulations and FCC KDB , Appendix A, Table A.1 4 : Rule Subpart/Technology Test Method Maximum Frequency Unintentional Radiators Part 15B ANSI C63.4: MHz Industrial, Scientific, and Medical Equipment Part 18 FCC MP-5 (February 1986) MHz Intentional Radiators Part 15C ANSI C63.10: MHz U-NIII without DFS Intentional Radiators Part 15E ANSI C63.10: MHz Commercial Mobile Services (FCC Licensed Radio Service Equipment) Parts 22 (cellular), 24, 25 (non-microwave), and 27 ANSI/TIA-603-D; TIA-102.CAAA-D MHz Citizens Broadband Radio Services (FCC Licensed Radio Service Equipment) Part 96 ANSI/TIA-603-D; TIA-102.CAAA-D MHz 4 Accreditation does not imply acceptance to the FCC equipment authorization program. Please see the FCC website ( for a listing of FCC approved laboratories. (A2LA Cert. No ) Revised 09/18/2017 Page 11 of 11

12 Accredited Laboratory A2LA has accredited TUV SUD CANADA Gormley, Ontario, Canada for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009). Presented this 4 th day of August President and CEO For the Accreditation Council Certificate Number Valid to June 30, 2019 For the tests to which this accreditation applies, please refer to the laboratory s Electrical Scope of Accreditation.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 INTERTEK TESTING SERVICES NA, INC. 7250 Hudson Blvd., Suite 100 Oakdale, MN 55128 Jay Kogoma or Michelle Loeffler Phone 651 730 1188 ELECTRICAL Valid to: February

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 CENTRE TESTING INTERNATIONAL GROUP CO., LTD. 1 Building C, Hongwei Industrial Park Block 70, Bao'an District Shenzhen, Guangdong, People s Republic of China

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 NATIONAL TECHNICAL SYSTEMS (NTS) - LONGMONT 1736 Vista View Drive Longmont, CO 80504-5242 Mr. Eric Loucks Phone: 303 776 7249 ELECTRICAL Valid To: August 31,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 INTERTEK TESTING SERVICES NA INC. 1950 Evergreen Blvd., Suite 100 Duluth, GA 30096 Gary Flom Phone 678 775 2334 ELECTRICAL Valid To: March 31, 2020 Certificate

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. F2 LABS Peters Road Middlefield, OH Wendy Fuster Phone: Ext.

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. F2 LABS Peters Road Middlefield, OH Wendy Fuster Phone: Ext. SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 F2 LABS 16740 Peters Road Middlefield, OH 44062 Wendy Fuster Phone: 301 253 4500 Ext. 101 ELECTRICAL (EMC) Valid To: November 30, 2019 Certificate Number: 0793.02

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 PARKER HANNIFIN CHOMERICS TEST SERVICES WOBURN, MA 84 Dragon Court Woburn, MA 01888 David Inman Phone: 781 939 4375 ELECTRICAL (EMC) Valid to: June 30, 2020

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SGS-CSTC STANDARDS TECHNICAL SERVICES CO., LTD Shenzhen Branch No.1 Workshop, M-10, Middle Section, Science and Technology Park Shenzhen, Guangdong, 518057,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 INTERTEK TESTING SERVICES SHANGHAI Bl. No. 86, 1198 Qinzhou Road (North) Shanghai 200233, PEOPLE S REPUBLIC OF CHINA Leah Xu leah.xu@intertek.com Phone: +86

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 MRT TECHNOLOGY (SUZHOU) CO., LTD. D8 Building, Youxin Industrial Park No. 2 Tina'edang Rd. Wuzhong Economic Development Zone Suzhou, Jiangsu, People s Republic

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 LABORATOIRE D ESSAIS CEM INC. 1490-D Nobel Street Boucherville, Quebec, Canada J4B 5H3 Mr. Xavier Couste Phone: 450 868 0360 Email: Xavier.Couste@nts.com ELECTRICAL

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SONY GLOBAL MANUFACTURING & OPERATIONS CORPORATION EMC/RF TEST LABORATORY - MAIN LAB 8-4 Shiomi Kisarazu-shi Chiba-ken, 292-0834, Japan Mr. Koichi.Hiyaoka Phone:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 COMPLIANCE CERTIFICATION SERVICES INC. 1 Kunshan Laboratory No. 10 Wei ye Road Innovation Park Eco & Tec. Development Zone Kunshan City, Jiangsu, People s Republic

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 MOTOROLA PENANG ADVANCED COMMUNICATION LABORATORY Motorola Solutions Malaysia Sdn Bhd (455657-H) Plot 2A, Bayan Lepas Technoplex Industrial Park Mukim 12 SWD,

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Labtest Certification, Inc. 3128, 20800 Westminster

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 TUV SUD AMERICA INC. 1 1775 Old Highway 8 NW, Suite 104 New Brighton, MN 55112 Mr. Barry Quinlan bquinlan@tuvam.com Phone: 978-573-2528 ELECTRICAL Valid To:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SHANGHAI INSPECTION AND TESTING INSTITUTE OF INSTRUMENTS AND AUTOMATION SYSTEMS CO., LTD. 103 Cao Bao Road Shanghai, 200233 People s Republic of China Mr. Xu

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 COMPLIANCE MANAGEMENT GROUP (CMG) 1 257 Simarano Drive, Suite 4 Marlborough, MA 01752 Authorized Representative: Mike Morrow Phone: 508 460 1400 ext. 222 Email:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 COMPLIANCE CERTIFICATION SERVICES, INC. 1 Xindian Laboratory No.163-1, Jhongsheng Road Xindian District, New Taipei City 23151, Taiwan, R.O.C. Contact: Kurt

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SHENZHEN ZHONGJIAN NANFANG TESTING CO., LTD. 1 No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road, Bao an District, Shenzhen, Guangdong,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 TUV RHEINLAND OF NORTH AMERICA, INC. 12 Commerce Road Newtown, CT 06470 Mr. Bruce Fagley: 203 426 0888 x119 Email: bfagley@us.tuv.com www.tuv.com ELECTRICAL

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 INTERTEK TESTING SERVICES NA, INC. 5 25800 Commercentre Dr. Lake Forest, CA 92630 Mr. Jay Kogoma Phone: 949-448-4100 ELECTRICAL Valid to: December 31, 2017

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ARTESYN PRODUCT TESTING SERVICES 2900 South Diablo Way, Suite 190 Tempe, AZ 85282 Tom Tuttle Phone: 602 228 7869 Email: tom.tuttle@artesyn.com ELECTRICAL (EMC)

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. CISCO SYSTEMS, INC. 170 West Tasman Drive San Jose, CA Mr. Gerald Thorpe Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. CISCO SYSTEMS, INC. 170 West Tasman Drive San Jose, CA Mr. Gerald Thorpe Phone: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 CISCO SYSTEMS, INC. 170 West Tasman Drive San Jose, CA 95134-1706 Mr. Gerald Thorpe Phone: 408 525 7602 ELECTRICAL Valid to: November 30, 2018 Certificate Number:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 NATIONAL TECHNICAL SYSTEMS (NTS) 1536 East Valencia Drive Fullerton, California 92831 Cathy Rumble Phone: (714) 879-6110 E-mail: cathy.rumble@nts.com Website:

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Washington Laboratories, Ltd. 7560 Lindbergh

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. NATIONAL TECHNICAL SYSTEMS Boyce Road Fremont, CA Ms. Laura Bader Phone:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. NATIONAL TECHNICAL SYSTEMS Boyce Road Fremont, CA Ms. Laura Bader Phone: SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 NATIONAL TECHNICAL SYSTEMS 1 41039 Boyce Road Fremont, CA 94538 Ms. Laura Bader Phone: 510 578 3500 ELECTRICAL (EMC) Valid to: September 30, 2019 Certificate

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 COMPLIANCE ENGINEERING PTY LTD 90 Indian Drive Keysborough, Victoria 3173, AUSTRALIA Mr. Simon Grilj Phone: 61 3 9763 3079 Email: simon@compeng.com.au ELECTRICAL

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 MET LABORATORIES, INC. 13501 McCallen Pass Austin, TX 78753 Frank Casbolt Phone: 512 287 2500 Frank.casbolt@metlabs.com http://www.metlabs.com I. ELECTRICAL

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 QAI LABORATORIES, INC. 1 834 80 th Street SW, Suite 200 Everett, WA 98203 Contact: Jarred Johnsen Phone: 425 512 8419 ELECTRICAL Valid To: February 28, 2017

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1 BUREAU VERITAS ADT (SHANGHAI) CORPORATION No.829, Xin Zhuan Road, Song Jiang District, Shanghai, China Ms. Amanda Cao (Authorized Representative) Phone: 86

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that LabTest Certification, Inc. 3128 20800 Westminster

More information

EMC Bayswater Pty Ltd

EMC Bayswater Pty Ltd EMC Bayswater Pty Ltd EMC BAYSWATER PTY LTD Accreditation Number: 18553 Site Number: 20485 Address Details: Unit 18, 88 Merrindale Drive CROYDON SOUTH, VIC 3136 AUSTRALIA Website: www.emcbayswater.com.au

More information

ANSI-ASQ National Accreditation Board/ACLASS

ANSI-ASQ National Accreditation Board/ACLASS ANSI-ASQ National Accreditation Board/ACLASS SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 Washington Laboratories, Ltd. 1, 2 7560 Lindbergh Drive, Gaithersburg, Maryland 20879 John Repella Phone: 301-216-1500

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 TUV SUD AMERICA INC. 10 Technology Drive (Test Laboratory) Peabody, MA 01960 Mr. William Stinson Phone 1 978 573 2517 ELECTRICAL Valid To: December 31, 2019

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 I.T.L. PRODUCT TESTING LTD. 1 1 Batsheva Street Lod, 7120101, ISRAEL Steli Loznen (Authorized Representative) Phone: 972 8 918 6100 x 203 E-mail: steli@itl.co.il

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 TÜV SÜD CERTIFICATION AND TESTING (CHINA) CO., LTD. 1 SHANGHAI BRANCH 3-13 F No. 151 Heng Tong Road Shanghai, 200 070, People's Republic of China Testing Location:

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 COSMOS CORPORATION 1 718-1, Katsurase-Cho Matsusaka-shi, Mie 515-1104 JAPAN Akira Sakai (Authorized Representative) +81 598-30-6211 sakai-akira@cosmos-corp.com

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Standards Institution of Israel Electricity

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Standards Institution of Israel Electronics

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that Standards Institution of Israel Electronics

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 EUROFINS PRODUCT SERVICE (THAILAND) CO., LTD. 1 344/2 Soi Soonvijai 4, Rama 9 Rd., Bangkapi, Huaykwang, Bangkok, 10320 Thailand Mr. Dirk Fleischer (Quality

More information

Compliance Engineering Ireland Ltd

Compliance Engineering Ireland Ltd Clonross, Dunshaughlin, Co. Meath Testing Laboratory Registration number: 088T is accredited by the Irish National Board (INAB) to undertake testing as detailed in the Schedule bearing the Registration

More information

Compliance Engineering Ireland Ltd

Compliance Engineering Ireland Ltd Clonross, Dunshaughlin, Co. Meath Testing Laboratory Registration number: 088T is accredited by the Irish National Board (INAB) to undertake testing as detailed in the Schedule bearing the Registration

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1 EUROFINS PRODUCT SERVICE (THAILAND) CO., LTD 344/2 Soi Soonvijai 4, Rama 9 Rd., Bangkapi, Huaykwang, Bangkok, 10320 THAILAND Mr. Dirk Fleischer (Quality Manager

More information

STS Directory Accreditation number: STS 0009

STS Directory Accreditation number: STS 0009 International standard: ISO/IEC 17025:2005 Swiss standard: SN EN ISO/IEC 17025:2005 Mettler-Toledo GmbH ENL Testing Laboratory Heuwinkelstrasse 3 8606 Naenikon SWITZERLAND Head: Bernhard Merk Responsible

More information

This annex is valid from: to Replaces annex dated: Prolonged until

This annex is valid from: to Replaces annex dated: Prolonged until Registration : L 022 This annex is valid from: 13-09-2017 to 01-03-2018 Replaces annex dated: 13-06-2016 Prolonged until 01-09-2018 Meander 1051 6825 MJ Arnhem The Netherlands Location(s) where activities

More information

Annex to the Accreditation Certificate D-PL according to ISO/IEC 17025:2005

Annex to the Accreditation Certificate D-PL according to ISO/IEC 17025:2005 Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-12121-01-00 according to ISO/IEC 17025:2005 Period of validity: 24.03.2017 to 30.09.2019 Holder of certificate: STC (Dongguan)

More information

AUGUST 2016 CONTENTS:

AUGUST 2016 CONTENTS: EMC SERVICES NEWSLETTER AUGUST 2016 CONTENTS: RECENT STANDARD CHANGES NEW FCC REGULATIONS IEC 60601-1-2 4TH EDITION LOW VOLTAGE DIRECTIVE EU DIRECTIVES EMC DIRECTIVE 2014/30/EU KOREA UPDATE: KN32/35 1.

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 INTERTEK TESTING SERVICES NA, INC. 1809 10 th Street, Suite 400 Plano, TX 75074 Authorized Representative: Charles Parker Phone: 972-202-8800 MECHANICAL Valid

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 HERMON LABORATORIES 1 68 Hatachana Street (Postal Mail to P.O. Box 23) Binyamina, 3055001, ISRAEL Mr. George Shleimovich Phone: 972 4 6288 001 Email: mail@hermonlabs.com

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AUSTRALIAN NATIONAL TESTING LABORATORIES PTY. LTD. Unit 17, 15 Suscatand Street Rocklea 4106, Queensland, Australia Jeff Profke Phone: 61 7 32740737 THERMAL

More information

ACMA mandated EMC standards

ACMA mandated EMC standards Part 1 Generic standards Item No. Applicable Standard Full Title of Standard Publication Date equipment type Standard being replaced AS/NZS 61000.6.3: 2012 30/04/2012 AS/NZS 61000.6.3: 2007 14/10/2015

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Stable Court Contact: Mark Richens Oakley Tel: +44 (0)1630 658568 Nr Market Drayton Fax: +44 (0)1630 658921 Shropshire E-Mail: mark@cranage.co.uk

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Wallace Way Tern Valley Business Park Market Drayton Shropshire TF9 3AG Contact: Mark Richens Tel: +44 (0) 1630 658568 E-Mail: mark@cranage.co.uk

More information

This is a preview - click here to buy the full publication

This is a preview - click here to buy the full publication TECHNICAL REPORT IEC TR 61000-4-1 Edition 1.0 2016-04 BASIC EMC PUBLICATION Electromagnetic compatibility (EMC) Part 4-1: Testing and measurement techniques Overview of the IEC 61000-4 series INTERNATIONAL

More information

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka Last Amended on 07.10.2015 Page 1 of 18 I. EMC Test Facility 1. Electrical and Electronic Products, Process Control Devices, Lighting Control Products, Sensing and Control Devices, Electromechanical Products,

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60044-7 First edition 1999-12 Instrument transformers Part 7: Electronic voltage transformers This English-language version is derived from the original bilingual publication

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. COLTS LABORATORIES, INC. 702 Stevens Avenue Oldsmar, FL Daryl Neely Phone: x204

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. COLTS LABORATORIES, INC. 702 Stevens Avenue Oldsmar, FL Daryl Neely Phone: x204 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 COLTS LABORATORIES, INC. 702 Stevens Avenue Oldsmar, FL 34677 Daryl Neely Phone: 727 725 2323 x204 MECHANICAL Valid To: August 31, 2018 Certificate Number:

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Unit 8 Contact: Mrs G Baker Woodfieldside Business Park Tel: +44 (0)1495 229219 Pontllanfraith Fax: +44 (0)1495 228331 Blackwood E-Mail: ginnie.baker@kiwa.co.uk

More information

Test Report. Appliance EMF Testing

Test Report. Appliance EMF Testing Project: 11014506A Date: November 6, 2015 Model: 120V_WWF13NW Test Report On Appliance EMF Testing Copyright 2005 UL LLC UL LLC authorizes the above-named company to reproduce this Report provided it is

More information

(Notices) EUROPEAN COMMISSION

(Notices) EUROPEAN COMMISSION 23.10.2012 Official Journal of the European Union C 321/1 IV (Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION Commission communication in the framework

More information

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION 11.11.2010 EN Official Journal of the European Union C 306/1 IV (Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION Commission communication in the framework

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK South Industrial Estate Bowburn County Durham DH6 5AD Contact: Andrew Nicholson Tel: +44 (0) 191 377 2000 Fax: +44 (0) 191 377 2020 E-Mail:

More information

RADIOCOMMUNICATIONS (EMC STANDARDS) NOTICE 2004 No. 2

RADIOCOMMUNICATIONS (EMC STANDARDS) NOTICE 2004 No. 2 RADIOCOMMUNICATIONS (EMC STANDARDS) NOTICE No. 2 Pursuant to regulation 32(1)(a), (b), (c), (d) and (j) of the Radiocommunications Regulations 2001, the Chief Executive, Ministry of Economic Development,

More information

C 271/32 Official Journal of the European Union

C 271/32 Official Journal of the European Union C 271/32 Official Journal of the European Union 12.11.2003 Commission communication in the framework of the implementation of the Council Directive 89/336/EEC (2003/C 271/04) (Text with EEA relevance)

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK South Industrial Estate Bowburn County Durham DH6 5AD Contact: Andrew Nicholson Tel: +44 (0) 191 377 2000 Fax: +44 (0) 191 377 2020 E-Mail:

More information

Commentary from a Certification Body. Mike Violette Director American Certification Body

Commentary from a Certification Body. Mike Violette Director American Certification Body Commentary from a Certification Body Mike Violette Director American Certification Body mikev@acbcert.com Background inarte-certified EMC Engineer Professional Engineer (Virginia) Founder, Washington Laboratories

More information

Product Tests Report

Product Tests Report TO WHOM IT MAY CONCERN Page: 1 of 5 Product name: Model number and description: MIC IP starlight 7000i Product Tests Report MIC-7502-Z30B, PTZ camera 2MP HDR 30x IP68 IK10, black MIC-7502-Z30W, PTZ camera

More information

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2016/C 293/03)

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2016/C 293/03) 12.8.2016 EN Official Journal of the European Union C 293/29 Commission communication in the framework of the implementation of Directive 2014/30/EU of the European Parliament and of the Council on the

More information

EMC & Wireless Certification

EMC & Wireless Certification EMC & Wireless Certification Your Key to Global Market Access Since 1872, TÜV Rheinland has been a world leader in compliance and testing, guaranteeing customer satisfaction with its expertise, attention

More information

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION 13.7.2018 EN Official Journal of the European Union C 246/1 IV (Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION Commission communication in the framework

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17065:2012

SCOPE OF ACCREDITATION TO ISO/IEC 17065:2012 SCOPE OF ACCREDITATION TO ISO/IEC 17065:2012 TEi-LISTING SERVICES 3455 S. 500 W. Salt Lake City, UT 84115 Mrs. Alona MacGregor (Authorized Representative) Phone: 801 262 1868 Email: alona@tei-test.com

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AUSTEST LABORATORIES 1 2/9 Packard Avenue Castle Hill, New South Wales 2154, AUSTRALIA Mr. Martin Garwood Phone: +61 2 9882 6500 ELECTRICAL Valid To: November

More information

Mains-related EMC-issues associated with Lighting Equipment. P.A. Beeckman PGI/Philips Innovation Services EMC Kennismarkt Oost - October 12, 2012

Mains-related EMC-issues associated with Lighting Equipment. P.A. Beeckman PGI/Philips Innovation Services EMC Kennismarkt Oost - October 12, 2012 Mains-related EMC-issues associated with Lighting Equipment P.A. Beeckman PGI/Philips Innovation Services EMC Kennismarkt Oost - October 12, 2012 EMC Center Philips Innovation Services Modeling & Simulations

More information

EU Declaration of Conformity Annex

EU Declaration of Conformity Annex The conformity of the designated product(s) with the provisions of the European Low Voltage Directive, /35/EU, is given by the compliance with the following European Standard(s) or other specifications.

More information

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2016/C 173/05)

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2016/C 173/05) C 173/142 EN Official Journal of the European Union 13.5.2016 Commission communication in the framework of the implementation of Directive 2014/30/EU of the European Parliament and of the Council on the

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 AUSTEST LABORATORIES MELBOURNE 53 Latitude Blvd. Thomastown, Victoria, 3074, Australia Martin Garwood Phone: +61 (0)3 9464 4016 Fax: +61 (0)3 9464 0687 ELECTRICAL

More information

Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616

Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616 TO WHOM IT MAY CONCERN Product Test report Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616 Product name: BOSCH FLEXIDOME IP outdoor 4000 HD/IR BOSCH FLEXIDOME IP outdoor

More information

EU Declaration of Conformity Annex

EU Declaration of Conformity Annex 2017 / 9C1- The conformity of the designated product(s) with the provisions of the European Low Voltage Directive is given by the compliance with the following European Standard(s) or other specifications.

More information

Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616

Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616 TO WHOM IT MAY CONCERN Product Test report Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616 Product name: BOSCH FLEXIDOME IP indoor 4000 HD/IR BOSCH FLEXIDOME IP indoor

More information

Kiwa Nederland B.V. Unit Appliances & Controls, Unit Automotive, Unit Gasdistribution Materials and Unit ExVision

Kiwa Nederland B.V. Unit Appliances & Controls, Unit Automotive, Unit Gasdistribution Materials and Unit ExVision of Kiwa Nederland B.V. Sir Winston Churchill-laan 273 2288 EA Rijswijk The Netherlands Location(s) where activities are performed under accreditation Head Office Location Abbreviation/ location code Main

More information

Direct dial: +44 (0) Date: 02 May 2012 Cust No Accr No Construction Products Directive

Direct dial: +44 (0) Date: 02 May 2012 Cust No Accr No Construction Products Directive Ms Clover Summers Sustainable Buildings Division Department for Communities and Local Government Eland House Bressenden Place London SW1E 5DU Direct dial: +44 (0)20 8917 8583 Email: alex.penfold@ukas.com

More information

How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab

How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab For questions and details contact Dennis at dennis@emitestlab.com Introduction The CE mark (an acronym for the French

More information

EU Declaration of Conformity

EU Declaration of Conformity Document number: Manufacturer or representative: Address: Brand name or trade mark: Product type: Product designation: 2015/ 9C1-3290710-EN-00 OSRAM GmbH Marcel-Breuer-Str. 6 80807 München Germany OSRAM

More information

Declaration of Conformity

Declaration of Conformity Declaration of Conformity DEMONSTRATION OF CONFORMITY WITH RECOGNIZED STANDARDS TO SATISFY THE SAFETY AND EFFECTIVENESS REQUIREMENTS OF THE CANADIAN MEDICAL DEVICES REGULATIONS Name of the medical device

More information

Instructions for use / Alarm unit, Fiber optic cable & Sensor patch ENGLISH

Instructions for use / Alarm unit, Fiber optic cable & Sensor patch ENGLISH Instructions for use / Alarm unit, Fiber optic cable & Sensor patch ENGLISH Manufacturer: Redsense Medical AB Gyllenhammars väg 26 302 92 HALMSTAD SWEDEN www.redsensemedical.com These instructions are

More information

EU Declaration of Conformity Annex

EU Declaration of Conformity Annex EU Declaration of Conformity Annex Document number: 2016 / 9C1-3423710-EN-00 The conformity of the designated product(s) with the provisions of the European radio equipment Directive is given by the compliance

More information

CE EMC Test Report EN :2015 EN :2017. Folder with powerbank ZKS E. Lieber Ouyang (Engineer) Lahm Peng (Manager)

CE EMC Test Report EN :2015 EN :2017. Folder with powerbank ZKS E. Lieber Ouyang (Engineer) Lahm Peng (Manager) CE EMC Test Report Test Standard(s): Applicant: Product Name: EN 55032 :2015 EN 55035 :2017 Goya Importacionesy Distribuciones SL B50154293 Folder with powerbank Model: 606090 Report No.: ZKS180800212E

More information

EU Declaration of Conformity

EU Declaration of Conformity 16 May 2017 EU Declaration of Conformity Model Number: ET1215L Series Equipment Category: Information Technology and Telecommunications Equipment Equipment Class: Commercial and Light Industrial Product

More information

EMC Emissions in the Machine Industry

EMC Emissions in the Machine Industry EMC Emissions in the Machine Industry Technical lecture by Herbert Blum 09.02.11 1 Programme > > Applicable Standard EN55011:2009 > Practical Examples 09.02.11 2 European Directives >The basic requirements

More information

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining

Test procedure/ method name. method identification. Testing of industrial and explosion isolation valves and tank lining The Laboratory is qualified to update standards identifying the test procedures. The laboratory requires/applies a flexible scope of accreditation permitted as detailed in the Annex. Updated list of activities

More information

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305 High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305 The new high-power Q305 laser is an expansion of the existing Q-Series that provides a solution for demanding applications requiring faster throughput.

More information

INDEX. Ⅰ. Company Overview. Ⅱ. Business Line. Ⅲ. Business Planning. Ⅳ. Appending - Certificates

INDEX. Ⅰ. Company Overview. Ⅱ. Business Line. Ⅲ. Business Planning. Ⅳ. Appending - Certificates INDEX Ⅰ. Company Overview Ⅱ. Business Line Ⅲ. Business Planning Ⅳ. Appending - Certificates Ⅰ. Company Overview 1. Company Outline Company Name CEO NTREE Co. Ltd. Hong Su Kim Stablished Feb. 2006. 30,

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 60533 Second edition 1999-11 Electrical and electronic installations in ships Electromagnetic compatibility Installations électriques et électroniques à bord des navires Compatibilité

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Accredited to ISO17065:2012 to provide product conformity Octagon House Concorde Way Segensworth North Fareham Hampshire PO15 5RL Contact: Mr Mark Jenkins Tel: +44 (0) 1489 558258 Fax: +44 (0)1489 558101

More information

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage. Product Bulletin VeriSafe Absence of Voltage The Safe Way to Verify Absence of Voltage. When servicing electrical equipment, workers must comply with safety regulations that require a voltage verification

More information

EMC in Industrial electronics PE:Region EMC/EMI in overview basic principles, current state of technology

EMC in Industrial electronics PE:Region EMC/EMI in overview basic principles, current state of technology EMC in Industrial electronics PE:Region EMC/EMI in overview basic principles, current state of technology Flensburg, Per Thåstrup Jensen February 2018 Agenda Why bother with EMC? The basic EMC parameters

More information

PROFESSIONAL TESTING (EMI), INC. TESTING CAPABILITIES N. A.W. Grimes Blvd, Suite B, Round Rock, TX

PROFESSIONAL TESTING (EMI), INC. TESTING CAPABILITIES N. A.W. Grimes Blvd, Suite B, Round Rock, TX PROFESSIONAL TESTING (EMI), INC. TESTING CAPABILITIES 1601 N. A.W. Grimes Blvd, Suite B, Round Rock, TX 78665 800.695.1077 Here at Professional Testing we re passionate about one thing... Bringing products

More information

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage Product Bulletin VeriSafe Absence of Voltage The Safe Way to Verify the Absence of Voltage. When servicing electrical equipment, workers must comply with safety regulations that require a voltage verification

More information

Products versus CISPR EMC standards

Products versus CISPR EMC standards Products versus CISPR EMC standards Which EMC standard has to be applied when testing a product for pre-compliance or compliance? The list on the following pages tries to give an answer to this question.

More information