1 PART IV CONVENTIONAL DETECTORS & DEVICES Morley-IAS Price list 2009v2

2 IV - Conventional Detectors and Devices ECO1000 Series - Conventional Detectors The ECO1000 conventional detectors range has been produced using the latest in manufacturing technology. * Integrated local alarm LED * Integrated remote alarm output * Automatic drift compensation * 8 to 30 Vdc operating range (Fire & security solutions) * -30 to +80 C operating temperature range * Manual test by using a laser-based hand test unit * Availability of a large range of bases BOSEC, LPCB & VdS approved EN54 Detectors ECO1003 1W OPTICAL CONVENTIONAL DETECTOR 27,95 ECO1005 1W RATE OF RISE THERMAL CONVENTIONAL DETECTOR 25,75 ECO1005T 1W FIXED THERMAL CONVENTIONAL DETECTOR (58 C) 25,75 ECO1004T 1W FIXED THERMAL CONVENTIONAL DETECTOR (78 C) 25,75 ECO1002 1W OPTICAL/THERMAL DETECTOR 38,75 Conventional Bases ECO1000B 1W STANDARD MOUNTING BASE 7,55 ECO1000BR 1W BASE WITH 470R RESISTOR 9,95 ECO1000DB 1W DEEP BASE 9,05 ECO1000DBR 1W DEEP BASE WITH 470R RESISTOR 10,95 ECO1000B 1W 12V RELAY BASE NON LATCHING 20,25 REL12NL Interface for 12V systems that do not provide a reset facility. Resets automatically the ECO detector when the fire alarm condition no longer exists. ECO1000B 1W 12V RELAY BASE LATCHING 20,25 REL12L Interface for 12V systems that latches the detector into alarm. The detector can only be reset by removing its supply voltage. The base can be used with 4 wire security systems that have a reset facility. ECO1000B 1W 24V RELAY BASE LATCHING 20,25 REL24L Interface for 24V system that require an external contact. The detector stays in alarm until the removing of its supply voltage. A break-off tab allows the base to be connected to fire control panels. This tab should be broken when there is little current flow or no current limiting resistor such as when used as a 24V stand-alone system. Conv. Detect. and Devices IV - 1 Release 2009 v2

3 Remote Indicators These items are integrated in part VII DETECTOR ACCESSORIES Please refer to your specific discount for this chapter to define your price IRK-2E 1W REMOTE INDICATOR LED See VII Surface mounted with the supplied mounting box. 12,75 IRK-E-SI 1W REMOTE INDICATOR LED See VII Surface mounted with the supplied mounting box. 13,85 IRK-W-624 1W LED TECHNOLOGY REMOTE INDICATOR IP Vdc See VII replace IRK-W ,00 Surface mounted Conv. Detect. and Devices IV - 2 Release 2009 v2

4 MCP Series - Manual Call points KAC Call Points - a range of indoor, outdoor and special environment products suitable for all applications. All products are available in a wide variety of colour and marking options. An extensive range of adaptor trays is available, allowing easy installation anywhere in the world. The MCP Call Points are compatible with standard electric embedded box with screws Further local territory approvals have been attained. LPCB approved EN54-11 Indoor (IP24) The series red MCP is LPCB approved EN54-11 The call points are delivered with the EN54-11 labels: Operating Element label: EN54-11 'dot & arrows' Function label: EN54-11 'Burning House' For other labels, please order specific foil additionally. RED MCP1A- 1W MCP FLUSH WITH BREAK GLASS ELEMENT 13,50 R470FG-01 2 outputs: Normally open (max 30Vdc) + monitoring resistor 470R Includes break glass MCP1A- 1W MCP FLUSH WITH FLEXIBLE ELEMENT 14,90 R470FF-01 2 outputs: Normally open (max 30Vdc) + monitoring resistor 470R Includes flexible operating element MCP2A- 1W MCP FLUSH WITH BREAK GLASS ELEMENT & LED 20,20 R470FG-01 2 outputs: Normally open (max 30Vdc) + monitoring resistor 470R Includes break glass MCP2A- 1W MCP FLUSH WITH FLEXIBLE ELEMENT & LED 21,60 R470FF-01 2 outputs: Normally open (max 30Vdc) + monitoring resistor 470R Includes flexible operating element MCP3A- 1W MCP FLUSH WITH BREAK GLASS ELEMENT 16,50 R000FG-01 with changeover contacts (max 30Vdc) Includes break glass MCP3A- 1W MCP FLUSH WITH FLEXIBLE ELEMENT 17,90 R000FF-01 with changeover contacts (max 30 Vdc) Includes flexible operating element Conv. Detect. and Devices IV - 3 Release 2009 v2

5 COLOR VERSION x = color type Y = yellow G = green B = blue W = white (lead time 4 weeks) Standards labels for the NOT RED MCP are: Operating Element label: EN54-11 'dot & arrows' Function label: Plain color For other labels, please order specific foil additionally. MCP3A- 1W MCP FLUSH WITH BREAK GLASS ELEMENT 21,50 x000fg-11 with changeover contacts (max 30 Vdc) Includes break glass MCP3A- 1W MCP FLUSH WITH FLEXIBLE ELEMENT 22,90 x000ff-11 with changeover contacts (max 30 Vdc) Includes flexible operating element MCP4A- 1W MCP FLUSH WITH BREAK GLASS ELEMENT 46,00 x000fg-12 with double pole changeover contacts (max 30 Vdc) Includes break glass MCP4A- 1W MCP FLUSH WITH FLEXIBLE ELEMENT 47,40 x000ff-12 with double pole changeover contacts (max 30 Vdc) Includes flexible operating element For Surface Mounting, please see Mounting Boxes Water Resistant (IP67) The call points are delivered with the EN54-11 labels: Operating Element label: EN54-11 'dot & arrows' Function label: EN54-11 'Burning House' For other labels, please order specific foil additionally. RED WCP3A- 1W MCP SURFACE WITH BREAK GLASS ELEMENT 126,50 R000SG-01 with single pole changeover (max 30 Vdc) Including surface mounting box and EN54 break glass WCP3A- 1W MCP SURFACE WITH FLEXIBLE ELEMENT 128,00 R000SF-01 with single pole changeover (max 30 Vdc) Including surface mounting box and EN54 Flexible Operating Element Conv. Detect. and Devices IV - 4 Release 2009 v2

6 WCP1A- 1W MCP SURFACE WITH BREAK GLASS ELEMENT 142,50 R470SG-01 Normally open (max 30 Vdc) + monitoring resistor 470R Including surface mounting box and EN54 break glass WCP1A- 1W MCP SURFACE WITH FLEXIBLE ELEMENT 144,00 R470SF-01 Normally open (max 30 Vdc) + monitoring resistor 470R Including surface mounting box and EN54 Flexible Operating Element COLOR VERSION x= color type Y = yellow B = blue G = green W = white Standards labels for the NOT RED MCP are: Operating Element label: EN54-11 'dot & arrows' Function label: Plain color For other labels, please order specific foil additionally. Y = yellow; G= Green; B = Blue; W = white WCP3A- 8W MCP SURFACE WITH BREAK GLASS ELEMENT 171,50 x000sg-11 with single pole changeover (max 30 Vdc) Including surface mounting box and EN54 break glass WCP3A- 8W MCP SURFACE WITH FLEXIBLE ELEMENT 173,00 x000sf-11 with single pole changeover (max 30 Vdc) Including surface mounting box and EN54 Flexible Operating Element WCP1A- 8W MCP SURFACE WITH BREAK GLASS ELEMENT 171,50 x470sg-11 Normally open (max 30 Vdc) + monitoring resistor 470R Including surface mounting box and EN54 break glass WCP1A- 8W MCP SURFACE WITH FLEXIBLE ELEMENT 173,00 x470sf-11 Normally open (max 30 Vdc) + monitoring resistor 470R Including surface mounting box and EN54 Flexible Operating Element Conv. Detect. and Devices IV - 5 Release 2009 v2

7 Accessories These items are integrated in part VII ACCESSORIES FOR MANUAL CALL POINTS & in part X SPARE PARTS KG1 X 10 1W SPARE EN54 BREAK GLASS FOR ALL KAC CALL POINTS See X PACK OF 10 16,20 PS230 1W SPARE EN54 FLEXIBLE OP. ELEMENTS FOR MCP See X PACK OF 10 20,40 PS200 1W TRANSPARENT PROTECTIVE HINGED COVER See VII 4,23 SC070 1W PACK OF 10 SPARE TEST KEYS See X 11,54 SC071 1W PACK OF 20 TERMINAL BLOCKS See X 81,00 KL1 X 5 1W PACK OF 5 EARTH CONTINUITY LINKS See VII 4,80 See VII BZR2 1W RED BEZEL FOR FLUSH INSTALLATION 3,75 W Series - Switches Standards labels for the series switches are: Function label: Plain color For other labels, please order specific foil additionally. x = color type R= red G = green W = white Y = yellow B = blue Key Switches Wx9101 8W KEY SWITCH 2 POSITIONS (KEY REMOVABLE IN BOTH POSITIONS) 49,25 Wx9102 8W KEY SWITCH 2 POSITIONS (KEY TRAPPED IN ONE POSITION) 52,90 Wx9103 8W KEY SWITCH 3 POSITIONS (KEY REMOVABLE IN 3 POSITIONS) 53,30 Wx9104 8W KEY SWITCH 36,30 Conv. Detect. and Devices IV - 6 Release 2009 v2

8 Rocker Switches Wx9201 8W ROCKER SWITCH 2 POSITIONS 50,50 double pole changeover contact Wx9202 8W ROCKER SWITCH DOUBLE POLE ON/OFF 45,60 with 220VAC red neon indicator Wx9203 8W ROCKER SWITCH 3 POSITIONS 57,30 Miniature Push Switches Non terminated Terminated Wx9301 8W MINIATURE SWITCH MOMENTARY ACTION, NON TERMINATED 41,30 Wx9302 8W MINIATURE SWITCH MOMENTARY ACTION, TERMINATED 55,70 Wx9303 8W MINIATURE SWITCH LATCHING, NON TERMINATED 34,90 Wx9304 8W MINIATURE SWITCH LATCHING, TERMINATED 67,30 Push Switches Wx9401 8W SWITCH SINGLE POLE, MOMENTARY ACTION (250VAC/24VDC-6A) 32,40 Wx9402 8W SWITCH 2 POSITIONS 94,00 Conv. Detect. and Devices IV - 7 Release 2009 v2

9 Mounting Boxes x = color type, please specify! R= red Y = yellow G = green B = blue W = white SR-P 1W SURFACE MOUNTING BOX RED 3,15 Sx-P 1W SURFACE MOUNTING BOX OTHER COLOR 4,85 Foil of Labels for Call Points & Switches These items are integrated in part VII foil of labels for CALL POINTS & SWITCHES Please refer to your specific discount for this chapter to define your price Each foil contains 48 labels MCP-LABEL F 007 1W FOIL OF 'PLAIN RED' LABELS (52,50) MCP-LABEL F 010 1W FOIL OF 'BRAND FEU' LABELS (black on red) (52,50) MCP-LABEL F 028 1W FOIL OF 'ALARME INCENDIE' LABELS (black on red) (52,50) MCP-LABEL F 056 1W FOIL OF 'BRAND FEU' LABELS (black on yellow) (52,50) MCP-LABEL F 081 1W FOIL OF 'FEU' LABELS (black on yellow) (52,50) MCP-LABEL F 082 1W FOIL OF 'BLUSKNOP' LABELS (black on yellow) (52,50) MCP-LABEL F 141 1W FOIL OF 'BRAND' LABELS (black on red) (52,50) MCP-LABEL F 103 1W FOIL OF 'GASBLUSSING' LABELS (black on yellow) (52,50) MCP-LABEL F 108 1W FOIL OF 'ALARME EVACUATION' LABELS (white on red) (52,50) MCP-LABEL F 120 1W FOIL OF 'BRAND ALARM' LABELS (black on red) (52,50) MCP-LABEL F 138 1W FOIL OF 'ALERTE INCENDIE' LABELS (black on red) (52,50) MCP-LABEL F 141 1W FOIL OF 'BRAND' LABELS (black on yellow) (52,50) MCP-LABEL F 217 1W FOIL OF 'EXTINCTION' LABELS (black on yellow) (52,50) MCP-LABEL F 218 1W FOIL OF 'RUNNING MAN' LABELS (white on green) (52,50) MCP-LABEL F 220 1W FOIL OF 'BIJ NOOD DEUR OPEN' LABELS (white on blue) (52,50) MCP-LABEL F 222 1W FOIL OF 'EN54 BURNING HOUSE' LABELS (white on red) (52,50) MCP-LABEL F 228 1W FOIL OF 'DEUR ONGRENDELING' LABELS (white on blue) (52,50) MCP-LABEL F 235 1W FOIL OF 'ALERTE WAARSCHUWING' LABELS (black on red) (52,50) MCP-LABEL F 244 1W FOIL OF 'UITSTEL BLUSSING' LABELS (white on blue) (52,50) Conv. Detect. and Devices IV - 8 Release 2009 v2

10 DH400 Series - DUCT DETECTORS Detectors DH400E 1W DUCT DETECTOR HOUSING 168,00 12/24VDC powered (operation range: 8,5 to 35VDC) This version contains no relays. Air velocity rating from 2,5 m/s to 20 m/s Connections for remote LED output, remote test station, remote annunciator The duct detector samples air passing through a duct and gives dependable performance for shutdown of fans, blowers or air co systems, so preventing the spread of toxic smoke and fire gases through the protected area. To order separately: 2151E Smoke Detector & ST-xx Inlet Sampling Tube DH400ACDCE 1W DUCT DETECTOR ASSEMBLY 205,00 24VDC or 24VAC operation Air velocity rating from 2,5 m/s to 20 m/s Equipped with DPDT Auxiliary Relay Contacts Sounder output, remote LED output, remote test station, remote annunciator Can be used as a part of fire detection system or as a stand alone duct smoke detector which can be used to activate a sounder and shutdown fans, blowers or air co systems, so preventing the spread of toxic smoke and fire gases through the protected area. To order separately: 2151E Smoke Detector & ST-xx Inlet Sampling Tube 2151 E 1W OPTICAL CONVENTIONAL SMOKE DETECTOR 66,00 For use with the duct detectors DH400E and DH400ACDCE. Note: The 2151 E detector is only available when it is ordered in combination with the DH 400 Series Duct Detectors Accessories These items are integrated in part VII Duct Detector Accessories & part X Sparte parts ST-1.5 1W INLET SAMPLING TUBE (LENGTH=457 MM) See VII 9,70 ST-3 1W INLET SAMPLING TUBE (LENGTH=916 MM) See VII 12,25 ST-5 1W INLET SAMPLING TUBE (LENGTH=1520 MM) See VII 16,85 ST-10 1W INLET SAMPLING TUBE (LENGTH=3255 MM) See VII 30,50 F W REPLACEMENT FILTER FOR DUCT DETECTORS See X 6,10 P W TUBE END PLUG FOR DUCT DETECTOR See X on request A W COMPLETE INSTALLATION KIT FOR DUCT DETECTOR See X on request Conv. Detect. and Devices IV - 9 Release 2009 v2

11 6500 Series - Beam Detectors The 6500R is a conventional reflector- type linear optical beam smoke detector designed to operate as a component of a conventional fire alarm system. He operates primarily on the principle of light obscuration utilising an Infra-Red beam. Optical beam smoke detectors are particularly appropriate for protecting buildings with large open spaces such as warehouses, atriums etc. The 6500R detector is a combined transmitter/receiver unit that can be directly connected to a conventional detector circuit. The Infra-Red transmitter generates a beam of light towards a high efficiency reflector. The reflector returns the beam to the receiver where an analysis of the received signal is made. Alignment of the detector is simplified with the aid of the detector s "gunsight" targeting device. Alignment of the detector with the reflector can then be fine tuned with the aid of a numerical signal strength indicator. The detector incorporates automatic drift compensation, whereby the detector will adjust its detection thresholds in line with any long term signal reduction of the beam caused by contamination of the optical surface. LPC, VdS & BOSEC Approved EN54-12: R Series Beam Detectors 6500R 1W CONV. REFLECTIVE IR BEAM DETECTOR 710,00 Infrared operation. Short range reflector (5M-75M) included. 12VDC (security systems) or 24VDC powered Standby Current: 17mA, Alarm Current: 38,5mA IP Rating: IP54 Detector Dimension: 254mm x 190mm x 84mm Reflector Dimension: 200mm x 230mm 6500RS 5w CONV. REFLECTIVE IR BEAM DETECTOR 840,00 WITH SELFTEST TOOL Same as 6500R with servo motored test tool Conv. Detect. and Devices IV - 10 Release 2009 v2

12 6500R Accessories These items are integrated in part VII DETECTOR ACCESSORIES Please refer to your specific discount for this chapter to define your price BEAM-LRK 1W LONG-RANGE REFLECTOR (75M-100M) II 3 reflectors with the following dimensions each: 235,00 Reflector Dimension: 200mm x 230mm BEAM-SMK 1W SURFACE MOUNTING BOX II Absolutly needed when using the mounting Bracket kit 29,60 BEAM-MMK 1W MOUNTING BRACKET - SWIVEL TYPE II 165,00 BEAM-HK 1W HEATER KIT FOR 6500R II To avoid condensation problems when used 126,50 in non heated rooms. BEAM-HKR 1W HEATER KIT FOR REFLECTOR II To avoid condensation problems when used 272,50 in non heated rooms. II 6500-RTS-KEY 1W REMOTE TEST KEY SWITCH 103,00 Conv. Detect. and Devices IV - 11 Release 2009 v2

13 FLAME DETECTORS Basic Series RIV-601/F 4W IP65 WATERPROOF IR FLAME DETECTOR 1760,00 10mA stand-by, 40mA in alarm at 24VDC. Field of view is 90 cone. Remote test input. Sensitivity: 2-3% of the distance. Adjustable alarm delay: 1 to 10 sec. Output: one changeover relay contact rated 2A 250VAC, and open collector output 50mA/24VDC Dimensions: 180 x 98 x 80 mm - Weight: 800g VdS approved EN class 2 (G205044) RIV-601/FA 4W RIV-601/F IR FLAME DETECTOR WITH EEX-PROOF ENCLOSURE 2930,00 SOR-873 4W VARIABLE DIRECTION STAND FOR RIV-601/F 285,00 SOA-875 4W VARIABLE DIRECTION STAND FOR RIV-601/FA 590,00 MINI 20/20 Series * Standard NON Eex * Multiple Detection Levels, 90 /90 Cone of Vision * Adjustable Time Delay * Stainless steel /20ML 5W UV/IR DETECTOR LOW POWERED 2165,00 20/20MI-1 5W TRIPLE IR DETECTOR LOW POWERED m - ATEX 3020,00 VdS approved (G207073)) 20/20MI-3 5W TRIPLE IR DETECTOR LOW POWERED - 2,5-10m - ATEX 3020,00 MINI 20/20 Series Accessories 20/ W SWIVEL MOUNT STAINLESS STEEL FOR 20/20-M SERIES 225,00 20/ W AIR SHIELD FOR MINI SERIES 195,00 20/20M-TOOLS 5W COMMISSIONING TOOLS KIT FOR MINI SERIES 510,00 Used for change default delay and default sensitivity Conv. Detect. and Devices IV - 12 Release 2009 v2

14 40/40 Series The new 40/40 Series Flame Detectors provide the most comprehensive protection against hydrocarbon-based fuel and gas fires, hydroxyl and hydrogen fires, as well as metal and inorganic fires. The detectors provide early warning of fires at long distances with high immunity to false alarms. The new 40/40 series designs are the highest performance, cost effective flame detectors currently on the market. New features include a stainless steel housing with a heated window, to eliminate condensation and icing; HART capabilities for digital communications; lower power requirements; and a compact, lightweight but highly durable and weather resistant design. The 40/40 flame detector series is highly reliable, with a newly extended 5-year warranty period and compliance with the IEC Safety Integrity requirements of SIL2. A leader in the flame and gas detection industry for over 15 years, Spectrex products are fully certified and employed around the world in a wide range of industrial and commercial facilities. the 40/40 series is standard Eexde for application in zone 1. Complies to EN54-10 (certification in pending) Complies to SIL2 (certification in pending) 40/40-U 5W UV DETECTOR 2885,00 40/40-UB 5W UV DETECTOR WITH BUILT IN TEST KIT 3770,00 40/40-L 5W UV/IR DUAL DETECTOR 3550,00 40/40-LB 5W UV/IR DUAL DETECTOR WITH BUILT IN TEST KIT 3955,00 40/40-L4 5W UV/IR (4,5µm) DUAL DETECTOR 3550,00 40/40-L4B 5W UV/IR (4,5µm) DUAL DETECTOR WITH BUILT IN TEST KIT 3955,00 40/40-I 5W TRIPLE IR DETECTOR 4920,00 40/40-M 5W MULTI SENSOR DETECTOR 5380,00 40/40-R 5W SINGLE IR DETECTOR 3430,00 40/40 Series Accessories 40/ W TILT MOUNT FOR 40/40 FLAME DETECTORS 222,00 40/40-ADD 5W CALIBRATION TO 85 C 303,50 40/40-DIAG 5W HANDHELD POCKET PC DIAGNOSTICS KIT 3055,00 40/ W AIR SHIELD 212,50 40/ W STAINLESS STEEL WEATHER COVER 222,00 40/ W LASER POINTER STANDARD 915,00 40/40-USB 5W USB CONNECTION CABLE FOR PC 505,00 Includes software Conv. Detect. and Devices IV - 13 Release 2009 v2

15 High Performance X Series Flame Detectors All flame detectors have the following features: * Aluminium copper free housing of stainless steel 316 version * IP66 protection * Micro controlled heated optics for increased resistance to moisture and ice. (not on X2200) * Built-in data logging/event monitoring. * MODBUS RS485 communication * Fire, fault and auxiliary relays. * Tricolor LED indicates normal operation, fire and fault * Integral wiring compartment for ease of installation * Mounting Swivel allows easy sighting. * RFI and EMC Directive Compliant * FM 3260 (2000) and ATEX Directive Compliant * For applications with high background radiation levels, such as turbine packages or off-shore facilities, the multispectral infrared X3301 is the ideal optical flame detector. * The X3302 multispectrum IR detector brings state-of-the-art flame detection to the difficult task of detecting invisible hydrogen flames. * The single frequency infrared X9800 is designed for high-pressure hydrocarbon flame detection or where high speed response and contamination resistance is critical. * The UV/IR X5200 is suited for applications such as aircraft hangars that could have UV radiation sources present. * For controlled environment applications requiring high speed response, the X2200 UV detector is the choice. X2200A 8W UV FLAME DETECTOR X2200A4M11W2 ALUMINIUM HOUSING 5150,00 Responds to all fire that emits UV radiation. It is suited where solar radiations are blind (battery rooms, high t location, Powder coating,..) Arc-unequalled false alarm rejection EN54-10 compliant (VdS: G203083) X2200S 8W SAME AS X2200A BUT WITH STAINLESS STEEL HOUSING 6415,00 X2200M 8W UV MOLLY BLACK POWDER FLAME DETECTOR X2200MA4M13W2 5800,00 ALUMINIUM HOUSING Responds to all fire that emits UV radiation. It is suited where solar radiations are blind (battery rooms, high t location, Powder coating,..) Arc-unequalled false alarm rejection EN54-10 compliant (VdS: G203083) X9800A 8W IR FLAME DETECTOR X9800A4M11W2 ALUMINIUM HOUSING 5150,00 Responds to radiation of hydrocarbon fires (Automotive Powder coating, Offshore platform, pipelines,..) Solar intensive. EN54-10 compliant (VdS: G203084) X9800S 8W SAME AS X9800A BUT WITH STAINLESS STEEL HOUSING 6415,00 Conv. Detect. and Devices IV - 14 Release 2009 v2

16 X5200A 8W UV/IR FLAME DETECTOR X5200A4M11W2 ALUMINIUM HOUSING 5695,00 Especially suited where hydrocarbon fires are likely and UV radiation sources may be present. (Aircraft hangars, loading racks, powder coating) EN54-10 compliant (VdS: G203085) X5200S 8W SAME AS X5200A BUT WITH STAINLESS STEEL HOUSING 6930,00 X3301A 8W MULTISPECTRAL IR FLAME DETECTOR X3301A4M11W2 6320,00 ALUMINIUM HOUSING Designed to detect hydrocarbon and not hydrocarbon fires. Alarm capabilities with modulated blackbody and other false alarm sources present. Features include increased range, sensitivity, coverage and false alarm rejection. Large range of applications EN54-10 compliant (VdS: G202136) X3301S 8W SAME AS X3301A BUT WITH STAINLESS STEEL HOUSING 7550,00 X3302A 8W MULTISPECTRAL IR NON VISIBLE FIRE DETECTOR 6320,00 X3302A4M11W2 ALUMINIUM HOUSING Solar resistance - Certified performance to Hydrogen, Silone fire types. Reliable flame detection with modulated IR background. EN54-10 compliant (VdS: G202136) X3302S 8W SAME AS X3302S BUT WITH STAINLESS STEEL HOUSING 7550,00 Conv. Detect. and Devices IV - 15 Release 2009 v2

17 X Series Accessories X-M25PG 4W M25 EEX d GLAND FOR X SERIES FLAME DETECTORS 154,00 Q9033B1000 8W MOUNTING SWIVEL STAINLESS STEEL 660,00 Allows easy mounting and sighting of detector assemblies W6300B1002 8W INSPECTOR CONNECTOR KIT 950,00 For configuration of the flame detectors heads UV, IR and UV/IR. Contains: RS485/232 converter, PSU 230Vac/24Vdc, DB9 connector Q2000A1001 8W ANTI STORM SIGHT-LEAF 360,00 Q2033A10R 8W ANTI STORM SIGHT-LEAF WITH 10 LIMITER OF VISIBILITY CONE 425,00 Q2033A20R 8W ANTI STORM SIGHT-LEAF WITH 20 LIMITER OF VISIBILITY CONE 425,00 Q2033A30R 8W ANTI STORM SIGHT-LEAF WITH 30 LIMITER OF VISIBILITY CONE 425,00 Q1116A1001 8W STANDARD AIR SHIELD 950,00 Air shields for reduced maintenance in areas where there is an abnormally high level of airborne contaminants. Q1118A1001 8W AIR SHIELD - ALUMINIUM 1420,00 Air shields for reduced maintenance in areas where there is an abnormally high level of airborne contaminants. Q1118S1001 8W AIR SHIELD - STAINLESS STEEL 2015,00 Air shields for reduced maintenance in areas where there is an abnormally high level of airborne contaminants W WINDOW CLEANER FOR FLAME DETECTOR 140,00 Conv. Detect. and Devices IV - 16 Release 2009 v2

18 Aspiration Systems A200 series Stand Alone Detectors The A200 series Stand Alone Aspirating Detectors is designed for the instances where the high sensitivity that is normally inherent in Aspiration detectors is an unnecessary expense or nuisance due to false alarms. The A200 series Stand Alone Aspiration Detectors will be connected to your system by using the on-board clean contacts to raise alarm condition. * Plastic housing (IP65 optional) * Supply voltage 18-30VDC - * One or two Fire relays (depend type) * One or two Fault relays (depend type) * IP50 rating (IP65 optional) VdS Approved EN54-20 (G206067) A211E-LSR 1W STAND ALONE ASPIRATING SYSTEM 1 CHANNEL (MAX 75M) 2.310,00 Completed with 1 laser Detector A222E-LSR 1W STAND ALONE ASPIRATING SYSTEM 2 CHANNELS (MAX 2 X 50M) 2.885,00 Completed with 2 laser detectors Max. sampling pipe length 100m 1 Sampling Air Inlet Ø 25 mm Sampling Pipes, Fittings & Accessories These items are integrated in part V INTELLIGENT DETECTORS Please refer to your specific discount for this chapter to define your price 02-FLU2 4W EXTERNAL FILTER FOR VERY HARSH ENVIRONMENT 546,00 Horizontal mounting, 2 inlets 25mm 02-WT-01 4W EXTERNAL WATER TRAP KIT 300,00 traps the water co 02-WT- 4W EXTERNAL WATER TRAP HEATER KIT 975,00 HEAT-01 Heats the air flow PFIL-EXT 6W EXTERNAL FILTER FOR VERY HARSH ENVIRONMENT 399,00 Vertical mounting Conv. Detect. and Devices IV - 17 Release 2009 v2

19 ABS 010 WARNING LABELS FOR CAPILARY SAMPLING POINT 30,30 ROLL OF 100 PIECES ABS 011 1W CEMENT 250ml 21,20 ABS 001/25 1W 90 SWEEPING BEND DIAMETER 25MM RED 102,00 PACK OF 10 ABS 001 2W WHITE VERSION OF ABS 001/25 111,00 /25-WH PACK OF 10 ABS 002/25 1W 45 SWEEPING BEND DIAMETER 25MM 47,40 PACK OF 10 ABS 002 2W WHITE VERSION OF ABS 002/25 50,00 /25-WH PACK OF 10 ABS 003/25 1W SOCKET UNION DIAMETER 25 MM 135,50 PACK OF 10 ABS 003 2W WHITE VERSION OF ABS 003/25 146,00 /25-WH PACK OF 10 ABS 004 1W PIPE CLIPS - RED 16,10 PACK OF 10 ABS 004-WH 1W WHITE VERSION OF ABS ,50 PACK OF 10 ABS 005/25 1W JOINTING SOCKET DIAMETER 25 MM 22,70 PACK OF 10 ABS 005 2W WHITE VERSION OF ABS 005/25 24,15 /25-WH PACK OF 10 ABS 005/1 1W 25MM TO 27MM ADAPTER 22,70 PACK OF 10 ABS 005 2W WHITE VERSION OF ABS ,00 /1-WH PACK OF 10 ABS 006/25 1W T' PIECE DIAMETER 25MM 121,00 PACK OF 10 ABS 006 2W WHITE VERSION OF ABS 006/25 131,00 /25-WH PACK OF 10 ABS 007/25 1W END CAP DIAMETER 25MM 22,70 PACK OF 10 ABS 007 2W WHITE VERSION OF ABS 007/25 24,15 /25-WH PACK OF 10 ABS 008/25 1W PIPE DIAMETER 25 MM - 3 METRES LONG 158,00 PACK OF 10 ABS 008 2W WHITE VERSION OF ABS 008/25 171,50 /25-WH PACK OF 10 Conv. Detect. and Devices IV - 18 Release 2009 v2

20 Remote Sampling Point Assemblies ABS 019C 1W CAPILLARY SAMPLING POINT- CONICAL HEAD 41,50 /25 TO CONNECT ON A ABS 008/25 PIPE Includes T-piece, 2 mtrs capillary tube & sampling point ABS 019C 2W WHITE VERSION OF ABS 019C/25 45,00 /25-WH ABS 019F/25 1W CAPILLARY SAMPLING POINT-FLUSH DISC 41,50 TO CONNECT ON A ABS 008/25 PIPE Includes T-piece, 2 mtrs capillary tube & sampling point ABS 019F 2W WHITE VERSION OF ABS 019F/25 45,00 /25-WH ABS 020/25 1W CAPILLARY SAMPLING POINT- DISCRETE SAMPLING POINT 8MM 36,00 TO CONNECT ON A ABS 008/25 PIPE Includes T-piece, 2 mtrs capillary tube & sampling point ABS 020 2W WHITE VERSION OF ABS 020/25 39,50 /25-WH ABS 019C 1W CAPILLARY END CAP SAMPLING POINT- CONICAL HEAD 36,00 /25EC TO CONNECT ON A ABS 008/25 PIPE Includes end cap reduction, 2 mtrs capillary tube & sampling point ABS 019C 2W WHITE VERSION OF ABS 019C/25EC 39,50 /25EC-WH ABS 019F 1W CAPILLARY END CAP SAMPLING POINT-FLUSH DISC 36,00 /25EC TO CONNECT ON A ABS 008/25 PIPE Includes end cap T-piece, 2 mtrs capillary tube & sampling point ABS 019F 2W WHITE VERSION OF ABS 019F/25EC 39,50 /25EC-WH ABS 020 1W CAPILLARY END CAP SAMPLING POINT- DISCRETE SAMPLING 30,30 /25EC POINT 8MM TO CONNECT ON A ABS 008/25 PIPE Includes end cap T-piece, 2 mtrs capillary tube & sampling point ABS 020 2W WHITE VERSION OF ABS 020/25EC 34,00 /25EC-WH Conv. Detect. and Devices IV - 19 Release 2009 v2

21 Components CAP-RED 1W 10mm NYLON TUBE - RED (per metre) 4,20 CAP-WHITE 1W 10mm NYLON TUBE - WHITE (per metre) 5,00 ABS 021/25 1W CAPILLARY END CAP FOR ABS 008/25 PIPE 16,50 Reduces 25 m pipe to 10mm pipe ABS 021 2W WHITE VERSION OF ABS 021/25 20,00 /25-WH ABS 022/25 1W CAPILLARY T PIECE FOR ABS 008/25 PIPE 24,85 Reduces 25 mm pipe to 10mm pipe ABS 022 2W WHITE VERSION OF ABS 022/25 27,50 /25-WH Conv. Detect. and Devices IV - 20 Release 2009 v2

22

V - Analogue Detectors and Devices Analogue Morley IAS Detectors MI Series The MI series is a range of intelligent detectors, which have been produced

V - Analogue Detectors and Devices Analogue Morley IAS Detectors MI Series The MI series is a range of intelligent detectors, which have been produced PART V INTELLIGENT DETECTORS & DEVICES Morley-IAS Price list 2009v2 V - Analogue Detectors and Devices Analogue Morley IAS Detectors MI Series The MI series is a range of intelligent detectors, which have

More information

Dräger Flame 2100 Flame Detection

Dräger Flame 2100 Flame Detection Dräger Flame 2100 Flame Detection Working in areas with combustible gases, vapors, or materials requires fire/ flame detection as a life-saving necessity. The best solutions must combine state-of-the-art

More information

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS MINERVA S200Plus Triple Waveband Infra-Red Flame Detection Features: Unrivalled black body rejection over a wide range of source temperatures Triple waveband infra-red solar blind flame detection for optimum

More information

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection DATASHEET S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection Features: Unrivalled black body rejection over a wide range of source temperatures Triple waveband infra-red

More information

Dräger Flame 2500 (IR3) Flame Detection

Dräger Flame 2500 (IR3) Flame Detection Dräger Flame 2500 (IR3) Flame Detection With its triple IR sensor The Dräger Flame 2500 detects hydrocarbonbased fires even over greater distances. Moreover, it offers a high reliability against false

More information

Dräger Flame 2350 (UV&IR) Flame Detection

Dräger Flame 2350 (UV&IR) Flame Detection Dräger Flame 2350 (UV&IR) Flame Detection The Dräger Flame 2350 combines UV and IR sensors for the detection of hydrocarbon-based fires. This combination of sensors offers you more security and fewer false

More information

Dräger Flame 2100 (UV) Flame Detection

Dräger Flame 2100 (UV) Flame Detection Dräger Flame 2100 (UV) Flame Detection A short response time and high reliability against false alarms are the features of the Dräger Flame 2100. Its UV sensor is quick to detect hydrocarbon- or hydrogen-based

More information

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger Flame 2700 (Multi-IR) Flame Detection Dräger Flame 2700 (Multi-IR) Flame Detection With its multichannel IR sensor the Dräger Flame 2700 detects hydrocarbon- and hydrogen-based fires. Thereby it offers a high reliability against false alarms.

More information

Dräger Flame 2370 (UV&IR) Flame Detection

Dräger Flame 2370 (UV&IR) Flame Detection Dräger Flame 2370 (UV&IR) Flame Detection An extremely short response time and very high reliability against false alarms are the features of the Dräger Flame 2370. It is quick and reliable in detecting

More information

Dräger Flame 2500 Flame Detection

Dräger Flame 2500 Flame Detection Dräger Flame 2500 Flame Detection Working in areas with combustible gases, vapours or materials requires fire/ flame detection as a life-saving necessity. The best solutions must combine state-of-the-art

More information

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508 Open-Path Gas Detection System SAFEYE XENON 700 Hydrocarbons and ethylene detection Heated optics 10-year Warranty for the Xenon flash bulb SIL 2 according to IEC 61508 Certifications The Fixed Gas Detection

More information

The SharpEye 40/40M (Multi IR) Flame Detection

The SharpEye 40/40M (Multi IR) Flame Detection The SharpEye 40/40M (Multi IR) Flame Detection requires fire/flame detection as a life-saving necessity The best solutions must combine state-of-the-art technology with rugged durability and be ready to

More information

The SharpEye 40/40I (IR3) Flame Detection

The SharpEye 40/40I (IR3) Flame Detection The SharpEye 40/40I (IR3) Flame Detection combine state-of-the-art technology with rugged durability and be ready to reliably work in any situation. Dräger offers a wide variety of high-quality flame-detectors

More information

Flame Detection Jon Sarfas

Flame Detection Jon Sarfas Flame Detection Jon Sarfas Agenda Introduction Detection Principles FL4000H MSIR Flame Detector Flame Test Lamp Installation Best Practice Features & Benefits Applications Introduction Primary objectives:

More information

The SharpEye 40/40R (IR) Flame Detection

The SharpEye 40/40R (IR) Flame Detection The SharpEye 40/40R (IR) Flame Detection requires fire/flame detection as a life-saving necessity The best solutions must combine state-of-the-art technology with rugged durability and be ready to reliably

More information

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions The Most Versatile Flame Detectors in the World Optical Flame Detection Solutions The Global Leader in Flame Detection Superior Performance and Reliability Flame detection is the very essence of the proud

More information

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700 We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP 0584389 LEL. METERS Open-path Gas Detection Concepts 40-meter path 7m wide cloud

More information

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions The Most Versatile Flame Detectors in the World Optical Flame Detection Solutions The Global Leader in Flame Detection Superior Performance and Reliability Flame detection is the very essence of the proud

More information

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection

The SharpEye 40/40L4-L4B (UV/IR) Flame Detection The SharpEye 40/40L4-L4B (UV/IR) Flame Detection requires fire/flame detection as a life-saving necessity The best solutions must combine state-of-the-art technology with rugged durability and be ready

More information

HigH Performance Low cost flame Detection. Courtesy of Foster + Partners. The New 20/20M MINI FLAME DETECTOR SERIES

HigH Performance Low cost flame Detection. Courtesy of Foster + Partners. The New 20/20M MINI FLAME DETECTOR SERIES HigH Performance Low cost flame Detection Courtesy of Foster + Partners The New 20/20M MINI FLAME DETECTOR SERIES High Performance, Low Cost Flame Detection The 20/20M Mini Series Flame Detectors are high

More information

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel Fixed Range Fixed Gas Detection Equipment Field mounted gas detection solutions for the protection of plant and personnel Fixed Range The Crowcon Fixed Gas Detector Range When lives and property are at

More information

Open-area Smoke Imaging Detection (OSID)

Open-area Smoke Imaging Detection (OSID) Open-area Smoke Imaging Detection (OSID) OSID Smoke Detection Open-area Smoke Imaging Detection (OSID) by Xtralis is a new innovation in projected beam smoke detection technology. By using advanced dual

More information

Intelligent addressable fire alarm control panel

Intelligent addressable fire alarm control panel Intelligent addressable fire alarm control panel Input current consumption: Panel rating: Batteries: Networking and Interfaces Panel to panel communication: Number of panels: Interface port: System capacity

More information

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features 990-052, Issue 6 20 March 2006 ID50 Series Single Loop Intelligent Fire Alarm Panels Section: Intelligent Fire Alarm Panels GENERAL The NOTIFIER ID50 series single loop intelligent fire alarm panels, has

More information

System 800 Addressable Fire Detection & Alarm System

System 800 Addressable Fire Detection & Alarm System SECTION 5: page 1 Section 5: System 800 Addressable Fire Detection & Alarm System SECTION 5: page 3 10 reasons to specify 800 1 Plug and Play A user friendly panel not requiring special software tools

More information

The SharpEye 40/40I (IR3) Flame Detection

The SharpEye 40/40I (IR3) Flame Detection The SharpEye 40/40I (IR3) Flame Detection combine state-of-the-art technology with rugged durability and be ready to reliably work in any situation. Dräger offers a wide variety of high-quality flame-detectors

More information

Evolution Analogue Addressable Fire System

Evolution Analogue Addressable Fire System Addressable Fire System optimum fire safety systems solutions High speed FSK protocol, uniquely resistant to noise Up to 254 addresses per loop for flexible system design Built to exceptional marine standards

More information

FAAST. Fire Alarm Aspirating Sensing Technology

FAAST. Fire Alarm Aspirating Sensing Technology FAAST Fire Alarm Aspirating Sensing Technology The FAAST range FAAST 8100e FAAST LT PipeIQ Next Generation Aspiration Detection Detection for Challenging Environments 3 in 1 Design, Confi guration and

More information

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

Why choose Fireray? Why use a Beam Smoke Detector? Product Range. Range Brochure Why use a? Beam smoke detectors are the wide area smoke detection technology of choice, offering both excellent detection and value for money. With a high area of coverage per unit (as high

More information

IR FLAME DETECTOR RIV-601/F

IR FLAME DETECTOR RIV-601/F IR FLAME DETECTOR EN 54-10 class 2 VdS approval G 205044 application manual CONTROL LOGIC rev. 4 DEC07 MAFE DEC07 IR FLAME DETECTORS SUMMARY Page general notions...3 description...4. Electrical and general

More information

FIRERAY 5000 range USER GUIDE

FIRERAY 5000 range USER GUIDE FIRERAY 5000 range USER GUIDE 0044-003-04 IMPORTANT PLEASE NOTE: The beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal.

More information

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Fixed Gas Detector Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors Dräger Polytron 5700 Including e-box for increased safety wiring The Dräger

More information

Line Smoke Detector LRMX

Line Smoke Detector LRMX Line Smoke Detector LRMX Motorized detector head User-friendly commissioning via automatic selfadjustment Disturbance-protected operation via automatic electromechanical tracking of the detector head during

More information

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors SAFETY MANUAL FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent

More information

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors. Fire Sentry Corporation (FSC) 593 Apollo Street Tel.: 714-671-1100 Brea, California 92821 Fax: 714-671-5821 Multi-Spectral, Digital, Infrared Electro-Optical FSC Model No. s FS10-R and FS10-A Unitized,

More information

LEARNING SPECIAL HAZARD DETECTION TYPES

LEARNING SPECIAL HAZARD DETECTION TYPES LEARNING SPECIAL HAZARD DETECTION TYPES JUNE 2013 COPYRIGHT CLIMATEC SPECIAL HAZARDS DETECTION TYPES EXPLAINED STAGE ONE DETECTION - ACTIVE AIR SAMPLING\\INCIPIENT AND IN- VISIBLE SMOKE STAGE AIR SAMPLING

More information

CODESEC FIRE ALARM SYSTEMS. security technologies

CODESEC FIRE ALARM SYSTEMS. security technologies CODESEC FIRE ALARM SYSTEMS security technologies AA402 ADRESSABLE FIRE ALARM CONTROL PANEL AA402 Electronic Addressable Intelligent Fire Alarm Control Panel Onboard one loop, 250 nodes per loop, Metal

More information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection The Hart XL High Sensitivity Smoke Detection system (HSSD) is an aspirating fire detection system designed to give very early indication of an incipient fire condition.

More information

IFD-E Flame Detector User Manual

IFD-E Flame Detector User Manual IFD-E Flame Detector User Manual 2 Hochiki Europe (UK) Ltd General Description The flame detector is designed for use where open flaming fires may be expected. It responds to the light emitted from flames

More information

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL GS100-ATEX Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL The GS100 beam set is a detection device only, and is designed to be used in

More information

FAAST. Fire Alarm Aspirating Sensing Technology

FAAST. Fire Alarm Aspirating Sensing Technology FAAST Fire Alarm Aspirating Sensing Technology The FAAST range FAAST 8100e FAAST LT PipeIQ Next Generation Aspiration Detection Detection for Challenging Environments 3 in 1 Design, Configuration and Monitoring

More information

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance IR4000 Point Infrared Combustible Gas Detection System The Reliable and Flexible Safety Solution That s Low Maintenance Multi-Point Gas Detection That s Fast Set-Up, Low Maintenance, Cost-Effective The

More information

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours Dräger Polytron Pulsar 2 Detection of flammable gases and vapours The Dräger Polytron Pulsar 2 is the latest infrared technology in open path gas detection. Equipped with all the same functions as the standard

More information

incontrol Systems Inc. Flame and Gas Detection

incontrol Systems Inc. Flame and Gas Detection incontrol Systems Inc. Flame and Gas Detection Our flame and gas detectors are globally certified to the latest product approval standards Wherever toxic or combustible gases are part of an industrial

More information

Dräger Polytron 7000 Fixed gas detector

Dräger Polytron 7000 Fixed gas detector DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Dräger Polytron 7000 Fixed gas detector ST-3751-2003 The Dräger Polytron 7000 is a gas detector that can satisfy all toxic and

More information

Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions!

Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions! Hazardous Locations Demand Superior Gas Detection! Quasar 900 provides the most reliable gas detection in all weather conditions! www.spectrex.net 2 SafEye Quasar 900 Series Open Path Gas Detector The

More information

Dräger Polytron Pulsar 2 Open Path Gas Detector

Dräger Polytron Pulsar 2 Open Path Gas Detector Dräger Polytron Pulsar 2 Open Path Gas Detector The Dräger Polytron Pulsar 2 represents the latest infrared technology in open path gas detection. Equipped with all the same functions as the standard Dräger

More information

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors SAFETY MANUAL X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors SAFETY-CERTIFIED Flame DETECTORs This manual addresses the specific requirements and recommendations applicable to the proper

More information

IFD-E Flame Detector User Manual

IFD-E Flame Detector User Manual IFD-E Flame Detector User Manual 2 Hochiki Europe (UK) Ltd General Description The flame detector is designed for use where open flaming fires may be expected. It responds to the light emitted from flames

More information

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times! USER GUIDE English IMPORTANT PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times! Failure to comply may result in the Detector initiating a Fire or Fault signal. Contents

More information

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL GS100-ATEX Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL The GS100 beam set is a detection device only, and is designed to be used in

More information

Beam Detectors. The 6500 Series

Beam Detectors. The 6500 Series Beam Detectors The 6500 Series The world s finest manufacturing facility System Sensor s European products are researched, designed and manufactured at our 10,000m 2 state-ofthe-art facility in Trieste,

More information

SIMRAD GD10PE IR GAS DETECTOR

SIMRAD GD10PE IR GAS DETECTOR SIMRAD GD10PE IR GAS DETECTOR Operating Manual P3404E 1st edition Jan. 2004 www.simrad-optronics.com CONTENTS 1. PRODUCT DESCRIPTION... 5 1.1 General description... 5 1.2 Construction... 5 1.3 Application

More information

Motorised Infrared Optical Beam Smoke Detector. User Guide

Motorised Infrared Optical Beam Smoke Detector. User Guide Motorised Infrared Optical Beam Smoke Detector User Guide EN 1. General Information 50cm 50cm 8-100m Ensure clear line of sight from Detector to Reflector Mount on solid surfaces (structural wall or girder)

More information

Reflective Beam Smoke Detector

Reflective Beam Smoke Detector Reflective Beam Smoke Detector SRA-ET Features! 5-30m range! Small flat reflector! Powered directly from the zone! Full line continuity options! Automatic compensation! Approved by LPCB & VdS Description

More information

Model 5610 Infra-red Transit Heat Sensor

Model 5610 Infra-red Transit Heat Sensor Model 5610 Infra-red Transit Heat Sensor MANUAL INSTALLATION - COMMISSIONING OPERATION - MAINTENANCE DOCUMENT REF. D1198 Issue Change Date Remarks 1 Original 25/09/13 Approved RJJ 2 Modifications to fig.

More information

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL P3359E 8th edition - November 2005 Simrad Optronics ASA Kabelgaten 4B P.O. Box 174, Økern NO-0509 OSLO, NORWAY Phone +47 22 66 60 00 Fax +47 22 66 60 01

More information

TECHNICAL SPECIFICATIONS BUTTONS

TECHNICAL SPECIFICATIONS BUTTONS Maxlogic beam type smoke detector consists of 2 parts as a receiver and transmitter. Should be mounted as facing each other between the distance of 5-100 m. The detector works on the principle of light

More information

Recalibrate the way you look at gas detection

Recalibrate the way you look at gas detection Catalogue Gas detection solution Recalibrate the way you look at gas detection Next generation gas detection for industrial refrigeration The next generation of Danfoss gas detectors are based on a digital

More information

Motorised Infrared Optical Beam Smoke Detector. User Guide

Motorised Infrared Optical Beam Smoke Detector. User Guide Motorised Infrared Optical Beam Smoke Detector User Guide EN 1. General Information 50cm 50cm 8-100m Ensure clear line of sight from Detector to Reflector Mount on solid surfaces (structural wall or girder)

More information

40/40 Series UV/IR Flame Detector Models 40/40L, LB and 40/40L4, L4B

40/40 Series UV/IR Flame Detector Models 40/40L, LB and 40/40L4, L4B 40/40 Series UV/IR Flame Detector Models 40/40L, LB and 40/40L4, L4B User Guide FM, CSA Approved: Class I Div. 1 Groups B, C, D Class II/III Div. 1 Groups E, F, G ATEX, IECEx Approved Ex II 2 GD, EExde

More information

Danfoss gas detection unit Type GD Heavy Duty

Danfoss gas detection unit Type GD Heavy Duty Data sheet Danfoss gas detection unit Type GD Heavy Duty The Heavy Duty gas detection units are used for monitoring and warning of hazardous Ammonia gas concentrations. They are intended for ATEX/ IECEx

More information

Flame Detector User Manual

Flame Detector User Manual This document is FD User Manual/003/Issue 1 User Manual General Description The flame detector is designed for use where open flaming fires may be expected. It responds to the light emitted from flames

More information

Contents. 1. Fire Detection motivation. 2. SharpEye Detector Range. 3. Detector Accessories. 4. How to Specify & Locate Detectors

Contents. 1. Fire Detection motivation. 2. SharpEye Detector Range. 3. Detector Accessories. 4. How to Specify & Locate Detectors 1 FLAME DETECTION Contents 1. Fire Detection motivation 2. SharpEye Detector Range 3. Detector Accessories 4. How to Specify & Locate Detectors 5. Application of Flame Detectors 2 Motivators to install

More information

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES DET-TRONICS SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION Eagle Quantum Premier is a configurable, distributed, intelligent safety system providing flame

More information

HART XL High Sensitivity Smoke Detection

HART XL High Sensitivity Smoke Detection High Sensitivity Smoke Detection Hart XL High Sensitivity Smoke Detection (HSSD) TM is a smoke detection system that is simple to install, commission, service and use yet remains brilliantly capable in

More information

Consultant Specification AGILE Wireless Fire Detection System

Consultant Specification AGILE Wireless Fire Detection System Contents Scope of Work... 2 The EN54 Part 2 & 4 Fire System... 2 Standards... 2 Wireless Intelligent Photoelectric Smoke Detector Specification... 4 Wireless Intelligent Thermal Heat Detector Specification...

More information

Flame Detector. Model: ZT-30P. User Guide. Document Ref: GLT Zeta Alarms Limited Morfa Road, Swansea, SA1 2EN, United Kingdom

Flame Detector. Model: ZT-30P. User Guide. Document Ref: GLT Zeta Alarms Limited Morfa Road, Swansea, SA1 2EN, United Kingdom Flame Detector Model: ZT-30P User Guide Document Ref: GLT-300-7-1 Zeta Alarms Limited 72 78 Morfa Road, Swansea, SA1 2EN, United Kingdom Phone: +441792 455 175 Fax: +441792 455 176 Website: www.zetaalarmsystems.com

More information

Application, Installation, Operation & Maintenance Manual

Application, Installation, Operation & Maintenance Manual APPROVED BY:JBJ PRESCIENT III FIRE ALARM & GAS EXTINGUISHING CONTROL PANEL Application, Installation, Operation & Maintenance Manual PAGE 1 of 43 CONTENTS 1. INTRODUCTION... 3 2. GENERAL DESCRIPTION...

More information

FIRERAY 2000 EExd Hazardous Area Smoke Detector Installation Guide

FIRERAY 2000 EExd Hazardous Area Smoke Detector Installation Guide FIRERAY 2000 EExd Hazardous Area Smoke Detector Installation Guide KEY FEATURES Flameproof Receiver and Transmitter Standard Fireray Controller Unit High Coverage - up to 1500 2 m per system Low Cost Beam

More information

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1 four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1 ANALOGUE FIRE DETECTION VIGILON COMPACT FEATURES & BENEFITS four Keep it Simple All Vigilon devices connect onto the same 2

More information

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System SAFETY MANUAL Open Path Hydrocarbon Gas Monitoring System The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically

More information

CHECKFIRE 210 Detection and Actuation System

CHECKFIRE 210 Detection and Actuation System DATA SHEET CHECKFIRE 210 Detection and Actuation System Features Supervised power, detection, release, and communication circuits Display module with LED system status indicators Adjustable mounting bracket

More information

SharpEye Flame Detector Selection Guide

SharpEye Flame Detector Selection Guide SharpEye Flame Detector Selection Guide Current Model Range and Characteristics Model Number* 40/40U-UB 20/20U-UB Detector Type Max. Detection Range** ft (m) Response Time (Typical) Description UV 50 (15)

More information

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5700 IR Detection of flammable gases and vapours Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive

More information

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY >OLYL >H]LSLUN[O 4H[[LYZ SMOKELESS FLARE MONITOR Smokeless Flare Monitor (FM) Smokeless flares incinerate flammable hazardous

More information

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features. Wireless Overview www.incitefire.com.au Overview Fundamentals FIREwave is a wireless based family of products which is fully integrated into Hochiki s renowned ESP intelligent hardwired system. This seamless

More information

COMPANY PROFILE Technoswitch with its headquarters, manufacturing and training facilities in Johannesburg, has been supplying and providing technical

COMPANY PROFILE Technoswitch with its headquarters, manufacturing and training facilities in Johannesburg, has been supplying and providing technical COMPANY PROFILE Technoswitch with its headquarters, manufacturing and training facilities in Johannesburg, has been supplying and providing technical support for high quality fire detection products into

More information

Flame Monitors BROCHURE

Flame Monitors BROCHURE Flame Monitors BROCHURE JUNHO 2013 monitor Self-monitoring and fail-safe compact flame monitor for the monitoring of gas, oil and coal flames with integrated UV, VIS or IR flame sensor, primarily in single

More information

SIMRAD GD10 IR GAS DETECTOR

SIMRAD GD10 IR GAS DETECTOR 1 SIMRAD GD10 IR GAS DETECTOR Operating Manual 5th Edition P3359E October 1999 1 CONTENTS Section Page 1. PRODUCT DESCRIPTION 3 1.1 General description 3 1.2 Construction 3 1.3 Application areas 4 1.4

More information

Intelligent Addressable Fire Alarm System

Intelligent Addressable Fire Alarm System Intelligent Addressable Fire Alarm System Company Profile The Company established in 2003, is manufacturing security system devices with the brand name DEKON Security Technologies for the exclusivity of

More information

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

SAFETY MANUAL. Multispectrum IR Flame Detector X3301 SAFETY MANUAL Multispectrum IR Flame Detector X3301 SAFETY-CERTIFIED MODEL X3301 MULTISPECTRUM INFRARED DETECTOR This manual addresses the specific requirements and recommendations applicable to the proper

More information

FCS-320-TM Series Conventional Aspirating Smoke Detectors

FCS-320-TM Series Conventional Aspirating Smoke Detectors Fire Alarm Systems FCS-320-TM Series Conventional Aspirating Smoke Detectors FCS-320-TM Series Conventional Aspirating Smoke Detectors For connecting to conventional fire panels High deceptive alarm immunity

More information

Ultra Fast UV/IR Flame Detector Model 40/40UFL

Ultra Fast UV/IR Flame Detector Model 40/40UFL Ultra Fast UV/IR Flame Detector Model 40/40UFL User Guide FM Approved Class I Div. 1 Groups B, C, D Class II/III Div. 1 Groups E, F, G ATEX, IECEx Approved Ex II 2 G D, Ex d e IIC T5 Gb Ex tb IIIC T96

More information

3600 Series UV/IR Flame Detector Models

3600 Series UV/IR Flame Detector Models 3600 Series UV/IR Flame Detector Models 3600L, LB and 3600L4, L4B User Guide FM, CSA Approved Class I Div. 1 Groups B, C, D Class II/III Div. 1 Groups E, F, G ATEX Approved Ex II 2G D Ex db eb op is IIC

More information

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700S

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700S SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700S We INVENTED it... We PERFECTED it! LEL. METERS Open-path Gas Detection Concepts 40-meter path 7m wide cloud 20% LEL 10% LEL 40% LEL 10% LEL SafEye Source

More information

Open-area Smoke Imaging Detection (OSID)

Open-area Smoke Imaging Detection (OSID) Open-area Smoke Imaging Detection (OSID) www.xtralis.com/osid Large, open spaces warehouses, airports, train stations, stadiums and shopping malls pose unique challenges to reliable fire detection due

More information

Conspec - Why use our Flame Detectors

Conspec - Why use our Flame Detectors Flame Detector Conspec - Why use our Flame Detectors Conspec Flame Detectors are ideal for applications where fast acting and accurate detection of fire is essential. Using infra-red (IR) sensing technology

More information

Fixed Gas Detection Equipment

Fixed Gas Detection Equipment CO 2 CI 2 NH 3 O 3 CO Fixed Gas Detection Equipment O 2 CH 4 O 2 CO 2 Field mounted gas detection solutions for the protection of plant and personnel D e t e c t o r s Xgard Detectors for Oxygen, Flammable

More information

ALK-V PHOTOELECTRIC SMOKE SENSOR

ALK-V PHOTOELECTRIC SMOKE SENSOR ALK-V PHOTOELECTRIC SMOKE SENSOR APPLICATION The HOCHIKI America ALK-V Photoelectric Smoke Sensor is particularly suited to detecting optically dense smoke typical of fires involving materials such as

More information

IGD.CO.UK

IGD.CO.UK APPLICATION DATA SHEET S p e c i f i c a t i o n 2 SO22 WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700+ D e t e c t o r Website: C o n t r o l P a n e l - Wall mounting or 19 Rack

More information

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION DET-TRONICS SPECIFICATION DATA Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION The EQ2200UVHT UV Flame Detector is used with the Eagle Quantum

More information

Instructions. Multispectrum IR Flame Detector X Rev: 1/

Instructions. Multispectrum IR Flame Detector X Rev: 1/ Instructions Multispectrum IR Flame Detector X3301 Rev: 1/16 Table of Contents DESCRIPTION....1 Outputs...1 LED...2 oi (Optical Integrity)...2 Communication....3 Data Logging....3 Integral Wiring Compartment...3

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS TC866E Series LASER ASPIRATED SMOKE DETECTOR

INSTALLATION AND MAINTENANCE INSTRUCTIONS TC866E Series LASER ASPIRATED SMOKE DETECTOR INSTALLATION AND MAINTENANCE INSTRUCTIONS TC866E Series LASER ASPIRATED SMOKE DETECTOR INTRODUCTION There are many instances where aspirated smoke detectors are specified, but where the very high sensitivity

More information

Model 3600R Single IR Flame Detector

Model 3600R Single IR Flame Detector Model 3600R Single IR Flame Detector User Guide FM, CSA Approved: Class I Div. 1 Groups B, C, D Class II/III Div. 1 Groups E, F, G ATEX Approved Ex II 2G D Ex db eb op is IIC T4 Gb Ex tb op is IIIC T96

More information

Dräger REGARD -1 Control System

Dräger REGARD -1 Control System Dräger REGARD -1 Control System The Dräger REGARD -1 is a standalone single-channel control system for the detection of toxic and Ex hazards and oxygen levels. The control system is fully configurable

More information

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version) PSC-SSS-PM Series Miniature Infrared Temperature Sensors with Optional Touch Screen Display PSC-SSS-PM with touch screen display (- version) FEATURES Miniature sensing head and configurable electronics

More information

Dependable Solutions for Gas Detection

Dependable Solutions for Gas Detection Dependable Solutions for Gas Detection Combustibles/Flammables Standard & Exotic Toxics Oxygen Enrichment/Deficiency Introduction to Sensidyne Established in 1983 - acquired by Schauenburg GmbH in April

More information

LASER ASPIRATED SMOKE DETECTOR

LASER ASPIRATED SMOKE DETECTOR LASER ASPIRATED SMOKE DETECTOR LASD1 (Single Channel) INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS (CE) 1 INTRODUCTION The LASD1 utilises one or two high-sensitivity laser point detectors in an aspirated

More information

Flexible Air-sampling Smoke Detection

Flexible Air-sampling Smoke Detection Flexible Air-sampling Smoke Detection BY Technology Pioneers in Highsensitivity Air-sampling Smoke Detection Systems Providing Solutions Beyond Traditional Smoke and Fire Detection Hochiki, a world-leader

More information