Ceodeux-Fire Extinguishers Valves Technology S.A.

Size: px
Start display at page:

Download "Ceodeux-Fire Extinguishers Valves Technology S.A."

Transcription

1 FireDeTec Automatic & autonomous Fire Extinguisher Systems Ceodeux-Fire Extinguishers Valves Technology S.A. 24 route de Diekirch B.P. 19 L-7505 Lintgen Luxembourg Tel: , Fax: ,

2 What is FireDeTec? Valve DLP1, DLP2, ILP, DHP, IHP Cylinder Containing: Water Foam Powder CO2 Halon replacement Argonite Etc.. FireDeTec tube Above fire risk area FireDeTec stops fires where they start in seconds

3 How does FireDeTec work? 10 seconds tube ruptures, releasing gas, extinguishing fire 5 seconds small fire begins 15 seconds the fire is out No fire is too small No risk too big

4 FireDeTec Automatic self seeking fire extinguisher Puts out fires when they start, where they start Designed for installation inside enclosures and inaccessible areas No complex electronics Safe against malfunction Best cost-performance ratio In less than the time it takes to read this The fire is out!

5 The direct system The extinguishing agent is transported through the FireDeTec tube exactly to the origin of the fire. Babyfire Your imagination is your only limitation

6 The indirect system The detection tube just triggers the valve when it detects a fire. The extinguishing agent discharges through a conventional outlet port. Babyfire Your imagination is your only limitation

7 FireDeTec Tube the difference acts as a multi-sensor and multi extinguishing jet Burst spot made of a high-tech polymer combines long-time resistance flexibility temperature sensitivity when bursting at the hottest spot, it ruptures as a nozzle shape opening You can t reach the fire? FireDeTec can

8 Bursttemperatur [ C] 140 Bursttemperatur = f (Internal pressure) Internal pressure [bar] Internal pressure of the FireDeTec tube (bar) Bursttemperature is in relation with the internal pressure of the tube Your imagination is your only limitation

9 Advantages Linear detection line Rapid reaction time 24 hours a day ready for use No external power supply Flexible positioning of the FireDeTec tube Can be installed into inaccessible areas Minimal environmental damages Minimum maintenance Especially good for locations where fire is a big risk

10 more advantages No accidental discharges through a disruption of the fire detector Can be used in every environment (marine, industrial atmosphere) Low and high pressure applications Governmental and insurance approvals Not affected by vibration or knocks Quick and simple installation Low price - high performance relationship When a fire can only be extinguished when small - FireDeTec

11 Low and high pressure valves B 0703 : Direct High Pressure valve (DHP) B 0702: Indirect High Pressure valve (IHP) B 0701 : Indirect Low Pressure valve (ILP) B 0704 : Direct Low Pressure valve with double head (DLP 2) FireDeTec - automatic fire detector & extinguisher

12 Some application examples Your imagination is your only limitation

13 Fix and mobile Your imagination is your only limitation

14 and big and small extreme locations No problem for FireDeTec Your imagination is your only limitation

15 etc. Your imagination is your only limitation

16 and many more Medical / Laboratory equipment Goods in transit Test / Production equipment Washing machines, dishwashers, fridges Vending machines Generator rooms Flammable liquid stores Storage areas Heavy plant & machinery Fume cupboards Switchgear Cable ducts Display cabinets Automated machinery Escalators Transmitters Motor vehicles Boats Your imagination is your only limitation

17 CO2 Layout example directional valve Your imagination is your only limitation

18 Solenoid valve In combination with FireDeTec Your imagination is your only limitation

19 Dimes Digital Measuring System Your imagination is your only limitation

20 References: Clients using our valves and components ALCAN Plant Process BLACK & DECKER Protection of plastic injection molding plant BRITISH GAS Offshore rig BRITISH NUCLEUR FUELS Fume cabinets BUXTED CHICKEN LTD. Feed Dryer cabinets CALGARY INTERNATIONAL AIRPORT Electrical control equipment for runway lights CATERPILLER Parts testing machine protection CHESTER ZOO Electric drive motors and switch gear on monorail system CHEVRON PETROLEUM NINIAN PLATFORM Fire deluge control CLAAS Combine harvesters JOHN DEERE Combine harvesters, for protection of turbo diesel engines ESSO PETROLEUM LTD. Protect engine test bays during extended engine running EXXON MOBILE Engine test bays FORD IVECO Robotic welding process FORD MOTOR CO. Research Department test beds FUJI FILMS Protection of photographic processing machines GB GLASS Beer glass manufacturing for the protection of process control equipment GLAXO PLC. Fume cupboard protection ICI ZENECA PHARMACEUTICALS Laboratory fume cabinets JCB LTD Plant machinery engine protection KIMBERLEY CLARKE Gas powered fork lift engines KODAK FILMS Photographic processing machines

21 LONDON STOCK EXCHANGE Transformer enclosures LOTUS OWNERS CLUB Classic cars MASSEY FERGUSON Combine harvesters MERCK Plant chemical storage MINISTRY OF DEFENCE Application-classified MOBIL OIL Petroleum production plant NORTH SHORE YACHTS Boat engine protection NORWICH UNION INSURANCE CO. Animated Lego display cabinets PFIZER Process computer controls PHILLIPS PETROLEUM Off-shore rig Air conditioning controls POLICE AUTHORITIES Riot Vehicles ROLLS ROYCE AERO ENGINES Carousel storage bins ROYAL BANK OF SCOTLAND Security Control Panel SHELL Off-shore rig SMITH KLINE AND BEECHAM Fume cabinets and chemical stores SONY Flow solder machines STATES OF JERSEY AMBULANCE SERVICE Ambulance protection STATES OF JERSEY EDUCATION COMMITTEE Minibus protection UNITOR SHIP SERVICE Marine fire protection UNITED STATES ARMY RESEARCH LAB Fume cabinet protection UNITED STATES AIR FORCE Cooker hoods

22 Approvals with system using our valves and components in following countries: Australia Austria Bahrain Belgium China Czech Republic Denmark France Germany Greece Hungary Israel Italy Netherlands Romania Your imagination is your only limitation

23 KLS Compact extinguisher system

24 Consequences of a fire Video anklicken

25 Dashboard Zone to protect by FireDeTec KLS Nozzles and extinguishing tubes

26 Extinguishing outlet FDT Detection tube Pressure sensor Vanne double détente

27 ADVANTAGES OF THE SYSTEM: Totally automatic and autonomous fire dectect and extinguishing No external power supply Flexible Installation Total emptying Compact integrated high pressure cylinder Optional: manual or electric actuation Easy to refill Various propulsion gases ( N2, compressed air,..) Liquid extinguishing agents Permanent pressure control Unpressuzrised liquid agent storage tank Constant outlet flow and pressure Minimal Maintenance

28 Applications KLS

Don t Compromise on Fire Safety Choose Certified Quality Products

Don t Compromise on Fire Safety Choose Certified Quality Products Don t Compromise on Fire Safety Choose Certified Quality Products THERMO-ACT AUTOMATIC FIRE DETECTION AND SUPPRESSION Quick, Automatic Fire Detection and Suppression Superior Coverage and Suppress Fires

More information

FIREDETEC PRODUCT TECHNOLOGY: DIRECT & INDIRECT

FIREDETEC PRODUCT TECHNOLOGY: DIRECT & INDIRECT FIREDETEC TECHNOLOGY: DIRECT & INDIRECT PROPERTIES DIRECT SYSTEM (< 1m 3 ) DETECTION TUBE : FIRE DETECTION & EXTINGUISHING AGENT DISCHARGE IDEAL APPLICATION: Small and hard to reach enclosures (< 1m 3

More information

PAFSS Fire Suppression Systems from Jactone. Automatic Fixed Fire Suppression Systems. JACTONE.COM/PAFSS +44 (0)

PAFSS Fire Suppression Systems from Jactone. Automatic Fixed Fire Suppression Systems. JACTONE.COM/PAFSS +44 (0) PAFSS Fire Suppression Systems from Jactone Automatic Fixed Fire Suppression Systems JACTONE.COM/PAFSS +44 (0)1902 357777 pafss@jactone.com Protect your assets from fire with PAFSS JACTONE.COM/PAFSS +44

More information

INDEPENDENT FIRE EXTINGUISHER SALES & SERVICES. Your First Line of Defense Since 1971

INDEPENDENT FIRE EXTINGUISHER SALES & SERVICES. Your First Line of Defense Since 1971 INDEPENDENT FIRE EXTINGUISHER SALES & Your First Line of Defense Since 97 Suppression Sales i Installation i Service ABOUT IFESSAR In business since 97 Serve over 4000 customers Service Arkansas and Mississippi

More information

PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS FOR SUGAR CANE HARVESTERS

PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS FOR SUGAR CANE HARVESTERS PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS FOR SUGAR CANE HARVESTERS AN IDEAL ENVIRONMENT TO START A FIRE CANE HARVERTERS WORK HARD DURING HARVEST Little time for maintenance Constant use - from one field

More information

SUPPRESSION SALES I INSTALLATION I SERVICE

SUPPRESSION SALES I INSTALLATION I SERVICE SUPPRESSION SALES I INSTALLATION I SERVICE ABOUT FESSAR In business since 1973 Serve over 4000 customers Service Arkansas and Mississippi Trained and certified suppression technicians Technicians are Arkansas

More information

Welcome to Argonite fire protection from Ginge-Kerr

Welcome to Argonite fire protection from Ginge-Kerr Welcome to Argonite fire protection from Ginge-Kerr Looking for fire protection of high value areas? Then you've come to the right place. As Halon systems go out, the Argonite system is coming in. All

More information

ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS

ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS ENGINEERING SPECIFICATIONS FOR FM-200 CLEAN AGENT INDIRECT PRE-ENGINEERED FIRE SUPPRESSION SYSTEMS SECTION 1 GENERAL SPECIFICATIONS I. SCOPE This specification outlines the requirements for a pre-engineered

More information

Fire Protection for Buses Micro environment protection

Fire Protection for Buses Micro environment protection Fire Protection for Buses Micro environment protection Details on fires in buses and how to suppress 1 them using FIRETRACE automatic suppression systems B ackground Information Bus Fires are a relatively

More information

Forum for European Electrical Domestic Safety FEEDS. B. DOME FISUEL

Forum for European Electrical Domestic Safety FEEDS. B. DOME FISUEL Forum for European Electrical Domestic Safety FEEDS B. DOME FISUEL Benoit.dome@gmail.com Twitter @FisuelEU Agenda 1. Participants 2. Objectives 3. White Paper 4. Conclusions 1.Participants Consumer Association

More information

Leading manufacturer of high-end ball valves and pneumatic actuators. Over 60 years experience with industrial applications

Leading manufacturer of high-end ball valves and pneumatic actuators. Over 60 years experience with industrial applications Company profile Leading manufacturer of high-end ball valves and pneumatic actuators Over 60 years experience with industrial applications We develop, manufacture and market our products HABONIM tailor-made

More information

Fire Protection for Manufacturing Facilities

Fire Protection for Manufacturing Facilities Fire Protection for Manufacturing Facilities Micro Environment Protection September 2009 Details on fires in manufacturing facilities and how to suppress them using FIRETRACE automatic suppression systems

More information

THE WORLD LEADER. in special hazard fire suppression solutions

THE WORLD LEADER. in special hazard fire suppression solutions THE WORLD LEADER in special hazard fire suppression solutions Firetrace was the first name in innovative fire suppression solutions and is the first to adapt to new technologies. Globally accepted as the

More information

Fire Protection for Cable Tunnels

Fire Protection for Cable Tunnels Fire Protection for Cable Tunnels Targeted protection November 2009 Details on fires in cable tunnels and how to suppress them using FIRETRACE automatic suppression 1 systems Background Information A fire

More information

Extinguishers. Commercial Industrial High rise buildings

Extinguishers. Commercial Industrial High rise buildings Commercial Industrial High rise buildings Extinguishers Design, Supply, Installation, Testing, Commissioning, Maintenance, and Service of Firefighting and Fire Protection Systems Think fire protection......thank

More information

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. 2 MistMax Low pressure WaterMist fire suppression skid Our modular fire skid is customised to suit your specific

More information

Fire Protection for Servers and Telecoms

Fire Protection for Servers and Telecoms Fire Protection for Servers and Telecoms Micro environment protection December 2009 Details on fires in communication equipment and how to suppress them using FIRETRACE automatic 1 suppression systems

More information

www.greenspower.com.sg 1company profile G reens Power have been at the forefront of Waste Heat Recovery Technology since Edward Green first patented the Fuel Economiser in 1845. The business developed

More information

NATO Stock Number

NATO Stock Number PORTALEVEL STANDARD 7th Generation Portable Ultrasonic Liquid Level Indicator for CO2, Halon, FM200, NAF S III, FE 13, CEA 410 & Novec 1230 gaseous extinguishing systems NATO Stock Number 6680-99-275-5292

More information

Accuracy counts! Sensors with analog output

Accuracy counts! Sensors with analog output Accuracy counts! Sensors with analog output Company Contrinex is a leading international high-tech sensor company with headquarters in Switzerland. Contrinex offers quality and highly innovative sensing

More information

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING THE MOST ADVANCED TECHNOLOGY FOR PROTECTING SPECIAL HAZARDS There are numerous hazards where the use of dry chemical is the best option for firefighting, and where the use of portable fire extinguishers

More information

Global Marine Solutions and Services From Ship to Shore Single Source Providers for Fire, Security, Life Safety

Global Marine Solutions and Services From Ship to Shore Single Source Providers for Fire, Security, Life Safety Safer. Smarter. Tyco. TM Global Marine Solutions and Services From Ship to Shore Single Source Providers for Fire, Security, Life Safety Specialists in Fire, Security & Life Safety Over 100 years experience

More information

AUTOMATIC FIREFIGHTING SYSTEMS IN KITCHENS

AUTOMATIC FIREFIGHTING SYSTEMS IN KITCHENS SPECIAL HAZARDS PROTECTION AUTOMATIC FIREFIGHTING SYSTEMS IN KITCHENS KP Hazard type Kitchens are usually closed rooms, inside a building also used for other purposes, in which food preparation activities

More information

automatic FiReFighTing SYSTeMS in PainT booths

automatic FiReFighTing SYSTeMS in PainT booths SPECIAL HAZARDS PROTECTION automatic FiReFighTing SYSTeMS in PainT booths hazard type The risks considered, according to existing regulations, are Class A risk: solids fire. Class B risk: fire of flammable

More information

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS

AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS SPECIAL HAZARDS PROTECTION AUTOMATIC FIREFIGHTING SYSTEMS IN PAINT BOOTHS Hazard type The risks considered, according to existing regulations, are Class A risk: solids fire. Class B risk: fire of flammable

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL SPECIFICATION SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION CEN/TS 14972 May 2008 ICS 13.220.20 English Version Fixed firefighting systems - Watermist systems - Design and installation Installations

More information

Detect. React. Benefit. Increase the availability of your plants with SIMATIC Notifier!

Detect. React. Benefit. Increase the availability of your plants with SIMATIC Notifier! Detect. React. Benefit. Increase the availability of your plants with! Unrestricted Siemens AG 2019 siemens.com/simatic-notifier New milestones of productivity with SIMATIC Notifier Page 2 Detect React

More information

Fire & Security Products. Siemens Flame Detector a highlight in detection. technology.

Fire & Security Products. Siemens Flame Detector a highlight in detection. technology. Fire & Security Products Siemens Flame Detector a highlight in detection technology. Keeping a very close eye on nature. Flames are a fascinating - but at the same time threatening - natural phenomenon.

More information

International Product Compliance and Certifications. Product Safety Consulting, Inc.

International Product Compliance and Certifications. Product Safety Consulting, Inc. International Product Compliance and Certifications - USA - Canada - Europe - Other International - CB Scheme Agenda This was the only mark. Now, these are the marks A bit of history.. UL founded in 1894

More information

Performance Based Fire Protection With Water Mist

Performance Based Fire Protection With Water Mist Performance Based Fire Protection With Water Mist the applications to industrial hazards, high rise buildings and other areas of interest PART 1 PART 2 PART 3 PART 4 PART 5 Marioff Corporation Why use

More information

KNX The worldwide STANDARD for home and building control. KNX Association International

KNX The worldwide STANDARD for home and building control. KNX Association International KNX The worldwide STANDARD for home and building control KNX Association International KNX is the Standard CENELEC EN 50090 the only European Standard for Home and Building Electronic Systems (HBES) based

More information

Element C3.4 Fire Fighting Equipment

Element C3.4 Fire Fighting Equipment .4 Fire Fighting Equipment Classification of Fires Class A Solids. Wood, paper, plastics Class B Liquids Petrol oil, paint Class C Gases LPG, natural gas Classification of Fires Class D Metals Zinc, sodium,

More information

Tel: Mecca Street Bldg 194, Amman, Jordan Mob:

Tel: Mecca Street Bldg 194, Amman, Jordan Mob: info@bonpet911.com Tel: +962 6 5521911 Mecca Street Bldg 194, Amman, Jordan Mob: +962 77 5521911 BONPET B O N P E T P PAGE A G E 1!"#$%&%'()*$+',-.! Bonpet is a European trademark for a unique liquid formula

More information

PTG, SWT Series. Heat Recovery Systems

PTG, SWT Series. Heat Recovery Systems PTG, SWT Series Heat Recovery Systems Hot air exhaust in summer Shutter Ducting system Available hot air Fresh air inlet Compressor Because of the enclosed, compact construction of screw compressors, it

More information

Forum for European Electrical Domestic Safety FEEDS. Residential Electrical Safety How to ensure progress?

Forum for European Electrical Domestic Safety FEEDS. Residential Electrical Safety How to ensure progress? Forum for European Electrical Domestic Safety FEEDS Residential Electrical Safety How to ensure progress? Plan Residential Electrical Safety- how to ensure progress? 1. Why does it matter 2. Origin of

More information

For more information on Tarkett go to

For more information on Tarkett go to Granit SD Toro SC STATIC CONTROL HOMOGENEOUS FLOORINGS VINYL iq Granit SD for static dissipation (10 6 R 10 8 Ω) iq Toro SC for static conductivity (5x10 4 R 10 6 Ω) Unique conductive iq PUR iq Unique

More information

Heating with pellets kw

Heating with pellets kw YOUR RELIABLE PARTNER Heating with pellets Present years on the market 110 for over 10-60 kw Competence is our success HERZ FACTS: 35 companies Group headquarters in Austria Research & development in Austria

More information

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING Chapter 30 FIRE-FIGHTING This Chapter discusses events which may follow cargo spillage and the procedures which can be adopted to protect life and property in such circumstances. It also describes the

More information

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES SHIPPING NOTICE Maritime Authority of the Cayman Islands Head Office 3 rd Floor, Government Administration Building, 133 Elgin Avenue PO Box 2256, Grand Cayman, KY1-1107, Cayman Islands Tel: +1 345 949

More information

CO 2 EXTINGUISHING SYSTEMS

CO 2 EXTINGUISHING SYSTEMS CO 2 EXTINGUISHING SYSTEMS CO 2 THE FIRE EXTINGUISHING CLASSIC: CLEAN, FAST AND RELIABLE TOTAL WALTHER, the acknowledged specialist in fire protection systems, has been manufacturing CO 2 extinguishing

More information

Highly Protected Risks in Power Generation Stewart Kidd outlines the issues to consider when installing active fire suppression in power stations THE

Highly Protected Risks in Power Generation Stewart Kidd outlines the issues to consider when installing active fire suppression in power stations THE Highly Protected Risks in Power Generation Stewart Kidd outlines the issues to consider when installing active fire suppression in power stations THE TERM highly protected risk (HPR) is commonly used in

More information

ILNAS-EN 1845:2007. Footwear manufacturing machines - Footwear moulding machines - Safety requirements

ILNAS-EN 1845:2007. Footwear manufacturing machines - Footwear moulding machines - Safety requirements Footwear manufacturing machines - Footwear moulding machines - Safety requirements Machines pour la fabrication de chaussures - Machines de moulage pour chaussures - Prescriptions de sécurité Maschinen

More information

CEN/TC 256 Overview. Presentation to ISCC January C Cork Chair CEN/TC CEN all rights reserved

CEN/TC 256 Overview. Presentation to ISCC January C Cork Chair CEN/TC CEN all rights reserved CEN/TC 256 Overview Presentation to ISCC January 2017 C Cork Chair CEN/TC 256 Overview of presentation CEN/TC 256 Organisation Developments in 2016 Key outputs Activities for 2017 2 CEN/TC 256 Committee

More information

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009 (II) 23, 25 June and 7, 9 July 2009 Organization by Co-organized by the Association of Registered Fire Service Installation contractors of Hong Kong Ltd (FSICA) Gas and Foam Suppression Systems Peter Bressington

More information

Keeping European Consumers safe Rapid Alert System for dangerous non-food products 2014

Keeping European Consumers safe Rapid Alert System for dangerous non-food products 2014 Keeping European Consumers safe Rapid Alert System for dangerous non-food products 2014 COMPLETE STATISTICS Justice and Consumers Directorate-General for Justice and Consumers Directorate Consumers Unit

More information

What is HI-FOG? The natural enemy of fire

What is HI-FOG? The natural enemy of fire What is HI-FOG? The natural enemy of fire Using water wisely in the fight against fire COOLS HI-FOG attacks the fire, cooling the fire itself and the space it is in. Water absorbs more heat (>2 MJ/kg)

More information

w-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI

w-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI W w-fog RG-SYSTEMS W-FOG WATER MIST CO-OPERATI WHY USE WATER MIST? Nowadays and increasingly, water is a scarce commodity. RG W-FOG s innovative design means that the amount of water used for fire protection

More information

English version. Alarm systems Terms and definitions

English version. Alarm systems Terms and definitions TECHNICAL REPORT CLC/TR 50531 RAPPORT TECHNIQUE TECHNISCHER BERICHT June 2009 ICS 01.040.13;13.320 English version Alarm systems Terms and definitions Systèmes d'alarme Termes et définitions Alarmanlagen

More information

PVC & PET FILMS FOR TOMORROW, TODAY.

PVC & PET FILMS FOR TOMORROW, TODAY. PVC & PET FILMS FOR TOMORROW, TODAY www.mondoplastico.com MONDOPLASTICO TODAY. Mondoplastico S.p.a. is a worldwide known PVC films producer, focused on high-quality calendered films. The company was established

More information

Identify RISKS. Design SOLUTIONS. Prevent DISASTERS

Identify RISKS. Design SOLUTIONS. Prevent DISASTERS We at FirePro Systems aim to Identify RISKS Design SOLUTIONS Prevent DISASTERS As Presenter I aim to arouse: INTEREST AWARENESS CONCERN You decide what is BEST for you HISTORY OF AEROSOL - Solid Potassium

More information

Building Services Brochure

Building Services Brochure Building Services Brochure A Midland Brand A Midland Brand Redefining Flow Control Contents Section Page Introduction to Building Services 3 Wet & Dry RIser Equipment 4 Gas Detection & Pressure Proving

More information

BOC FS125 The Fire Extinguishing Solution

BOC FS125 The Fire Extinguishing Solution BOC FS125 The Fire Extinguishing Solution Background - Montreal Protocol With the introduction of the Montreal Protocol in 1987, Halon is no longer available in most countries and alternatives must be

More information

Fire Protection for Printing Machines with High Pressure Water Mist

Fire Protection for Printing Machines with High Pressure Water Mist Fire Protection for Printing Machines with High Pressure Water Mist Dipl.-Ing. Rüdiger Kopp FOGTEC Fire Protection ruediger.kopp@fogtec.com 1 Case Study PRINOVIS Printing Company - PRINOVIS is Europe s

More information

FIRE STOP 200/30. High technology system for first attack of fire with high pressure nebulized water (Water mist) FD 907. Ed.

FIRE STOP 200/30. High technology system for first attack of fire with high pressure nebulized water (Water mist) FD 907. Ed. NCAGE A5009 CONFORM TO THE QUALITY SYSTEM STANDARD AQAP 2110 and ISO 9001:2008 FD 907 Ed. 07/2016 FIRE STOP 200/30 High technology system for first attack of fire with high pressure nebulized water (Water

More information

ABOUT US. Established in 1978, Jactone Products Ltd is a leading UK manufacturer and distributor of high quality, unique fire fighting products.

ABOUT US. Established in 1978, Jactone Products Ltd is a leading UK manufacturer and distributor of high quality, unique fire fighting products. EXPORT BROCHURE ABOUT US Established in 1978, Jactone Products Ltd is a leading UK manufacturer and distributor of high quality, unique fire fighting products. As well as fire fighting products, we also

More information

Exploration and extraction can be on land or on offshore platforms. Once extracted, ground transportation is done by means of oil or gas pipelines,

Exploration and extraction can be on land or on offshore platforms. Once extracted, ground transportation is done by means of oil or gas pipelines, Oil & Gas Exploration and extraction can be on land or on offshore platforms. Once extracted, ground transportation is done by means of oil or gas pipelines, FPSO vessels, tankers, LNG carriers, etc. The

More information

Theoretical Background

Theoretical Background Theoretical Background National Annexes to EN 1999 All information in this document is subject to modification without prior notice. No part or this manual may be reproduced, stored in a database or retrieval

More information

Gas meters - Conversion devices - Part 1: Volume conversion

Gas meters - Conversion devices - Part 1: Volume conversion EESTI STANDARD EVS-EN 12405-1:2005 Gas meters - Conversion devices - Part 1: Volume conversion Gas meters - Conversion devices - Part 1: Volume conversion EESTI STANDARDIKESKUS EESTI STANDARDI EESSÕNA

More information

List of nationally authorised medicinal products

List of nationally authorised medicinal products 3 December 2015 EMA/40805/2016 Procedure Management and Committees Support Active substance: human anti-d immunoglobulin Procedure No.: PSUSA/00001614/201503 30 Churchill Place Canary Wharf London E14

More information

Fire Suppression Solutions

Fire Suppression Solutions DESIGNED & MADE IN AUSTRALIA AS5062-2006 Listed Fire Suppression Solutions Pirtek offers design, installation, commissioning and maintenance of Fire Suppression solutions for mobile equipment for your

More information

V201 INSTALLATION MANUAL & USER MANUAL

V201 INSTALLATION MANUAL & USER MANUAL Filtration system for safety cabinet V201 INSTALLATION MANUAL & USER MANUAL www.erlab.com ConTenTS 1 - Installation and start-up 2 - First start: Fan Failure setting 3 -Control Panel description 4 - Molecular

More information

CO2 COCO GAS FLOODING SYSTEM

CO2 COCO GAS FLOODING SYSTEM PRE INTRODUCTION: CO2 COCO GAS FLOODING SYSTEM The importance of erection, testing and commissioning are overlooked, in many projects while installing fixed Co2 extinguishing system. It is very common

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 13938-1 First edition 1999-08-01 Textiles Bursting properties of fabrics Part 1: Hydraulic method for determination of bursting strength and bursting distension Textiles Propriétés

More information

REFRIGERATING SYSTEMS AND HEAT

REFRIGERATING SYSTEMS AND HEAT IRISH STANDARD I.S. EN 12693:2008 ICS 23.140 27.080 National Standards Authority of Ireland Northwood, Dublin 9 Ireland Tel: +353 1 807 3800 Fax: +353 1 807 3838 http://www.nsai.ie REFRIGERATING SYSTEMS

More information

Heat Pipe Applications Introduce

Heat Pipe Applications Introduce Heat Pipe Applications Introduce Most suitable where: Low humidity level necessary Humidity control required Air reheated after cooling in traditional HVAC system Large quantities of ventilation air needed

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL SPECIFICATION SPÉCIFICATION TECHNIQUE TECHNISCHE SPEZIFIKATION CEN/TS 1555-7 January 2013 ICS 23.040.01; 91.140.40 Supersedes CEN/TS 1555-7:2003 English Version Plastics piping systems for the

More information

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS PART 8. PORTABLE FIRE EXTINGUISHERS DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE GENERAL INDUSTRY SAFETY STANDARDS (By authority conferred on the director of the department of licensing and regulatory affairs by sections

More information

GAS EXTINGUISHING SYSTEMS INERT GAS. Argotec with argon or nitrogen

GAS EXTINGUISHING SYSTEMS INERT GAS. Argotec with argon or nitrogen GAS EXTINGUISHING SYSTEMS INERT GAS Argotec with argon or nitrogen NATUR AL without any damage to the atmosphere The extinguishing gases Argon and nitrogen extinguish a fire by oxygen displacement. When

More information

A safe journey with Dräger CRUISE CATALOGUE

A safe journey with Dräger CRUISE CATALOGUE A safe journey with Dräger CRUISE CATALOGUE Introduction ADVANTAGES Total FRS package Fast delivery 24/7, 365 days support Largest FRS product range Top quality Worldwide Dräger locations SAFETY ON BOARD

More information

Weishaupt WKmono 80. The next-generation burner for ratings up to kw. That s reliability

Weishaupt WKmono 80. The next-generation burner for ratings up to kw. That s reliability Weishaupt WKmono 80 The next-generation burner for ratings up to 17 000 kw That s reliability Weishaupt WKmono 80: The next-generation monobloc burner The powerful output offered by the new WKmono 80 burner

More information

SANS 21-1:2009 Edition 1 EN 115-1:2008

SANS 21-1:2009 Edition 1 EN 115-1:2008 ISBN 978-0-626-22589-6 EN 115-1:2008 SOUTH AFRICAN NATIONAL STANDARD Safety of escalators and moving walks Part 1: Construction and installation This national standard is the identical implementation of

More information

AERO 20 AERO ENGLISH - Operating Instructions

AERO 20 AERO ENGLISH - Operating Instructions www.nilfisk-alto.com AERO 20 AERO 25 302002328-2008-05-21 ENGLISH - Operating Instructions Important safety instructions Before using the vacuum cleaner, always read the operating instructions and keep

More information

SECURITY BLANKET Foam Fire Protection Products

SECURITY BLANKET Foam Fire Protection Products SECURITY BLANKET Foam Fire Protection Products REAL DANGERS DEMAND REAL SOLUTIONS If your business manufactures, stores, or transports flammable liquids, the thought of a devastating fire always burns

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CEN/TR 14383-5 January 2010 ICS 13.310; 91.020 English Version Prevention of crime - Urban planning and building design - Part 5: Petrol stations

More information

Explosion isolation systems

Explosion isolation systems BRITISH STANDARD BS EN 15089:2009 Explosion isolation systems ICS 13.230 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW National foreword This British Standard is the UK implementation

More information

Fire protection for buildings

Fire protection for buildings Fire protection for buildings HI-FOG high-pressure water mist Ghelamco Group Protecting people, property and business continuity A fire in a building can lead to serious consequences. Even a harmless fire

More information

This document is a preview generated by EVS

This document is a preview generated by EVS TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CEN/TR 1749 June 2014 ICS 91.140.40 Supersedes CEN/TR 1749:2009 English Version European scheme for the classification of gas appliances according

More information

DRY BULK HANDLING SYSTEM

DRY BULK HANDLING SYSTEM DRY BULK HANDLING SYSTEM Parson Marine Equipment is established in Singapore since July 2005. Our team of engineers have more than 25 years of experiences in providing customised integrated dry and wet

More information

Installation Instructions

Installation Instructions Installation Instructions About This Document Use this document to install the 1784-PCM4/B cable. This cable connects the 1784-PCMK/B card to an SLC 5/01, 5/02, or 5/03 processor or a 1747-AIC link coupler

More information

This document is a preview generated by EVS

This document is a preview generated by EVS EESTI STANDARD EVS-EN 14175-6:2006 Fume cupboards - Part 6: Variable air volume fume cupboards Fume cupboards - Part 6: Variable air volume fume cupboards EESTI STANDARDIKESKUS EESTI STANDARDI EESSÕNA

More information

Global Marine Solutions. From Ship to Shore, single source providers for Fire Protection, Electronic Security, Life-Safety and Communications Systems

Global Marine Solutions. From Ship to Shore, single source providers for Fire Protection, Electronic Security, Life-Safety and Communications Systems Global Marine Solutions From Ship to Shore, single source providers for Fire Protection, Electronic Security, Life-Safety and Communications Systems Specialists in Fire, Security, Communications Systems

More information

WATER MIST CONVENTION AND EXHIBITION

WATER MIST CONVENTION AND EXHIBITION INTERNATIONAL WATER MIST ASSOCIATION IWMA SEMINARS S ON WATER MIST TECHNOLOGY DUBAI INTERNATIONAL CONVENTION AND EXHIBITION CENTRE Water mist fire protection: The most innovative fire fighting technology

More information

Safe, Effective, Environment-friendly

Safe, Effective, Environment-friendly IG-55 (Argon/Nitrogen) Safe, Effective, Environment-friendly Introduction With the phase out of the most commonly used but environmentally damaging Halon 1301 and CO 2 fire suppressant, inert gases are

More information

Textile fire protection closures EI 30/90

Textile fire protection closures EI 30/90 Textile fire protection closures EI 30/90 Hidden Shield EI 30 Hidden Shield EI 90 10. World Novelty and this has already been awarded! Double / two-sided fire protectionroller shutter construction > EI60

More information

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. TM TM

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. TM TM MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. TM TM 2 MistMax Low pressure water mist fire suppression skid Our modular fire skid is customised to suit your

More information

ISO INTERNATIONAL STANDARD. Packaging Tactile warnings of danger Requirements. Emballages Indications tactiles de danger Exigences

ISO INTERNATIONAL STANDARD. Packaging Tactile warnings of danger Requirements. Emballages Indications tactiles de danger Exigences INTERNATIONAL STANDARD ISO 11683 Second edition 1997-10-01 Corrected and reprinted 1998-09-01 Packaging Tactile warnings of danger Requirements Emballages Indications tactiles de danger Exigences A Reference

More information

Return loss measurement of fiber optic components

Return loss measurement of fiber optic components Return loss measurement of fiber optic components Solutions Brief 815-1 How the HP 8153A/HP 81534A measure return loss of fiber optic components? The significance of return loss The introduction of new

More information

This document is a preview generated by EVS

This document is a preview generated by EVS EESTI STANDARD EVS-EN 12094-2:2003 Paiksed tulekustutussüsteemid. Gaasikustutussüsteemide komponendid. Osa 2: Nõuded ja kontrollmeetodid mitte-elektrilistele automaatsetele juhtimis- ja viitega seadmetele

More information

SOLUTION CATALOG Kytola Oval Flow Oil Lubrication Monitoring System

SOLUTION CATALOG Kytola Oval Flow Oil Lubrication Monitoring System www.kytola.com SOLUTION CATALOG Kytola Oval Flow Oil Lubrication Monitoring System Kytola Oval Flow Oil Lubrication Monitoring Systems 24/7/365 Reliability Proper bearing and gear lubrication is essential

More information

This document is a preview generated by EVS

This document is a preview generated by EVS EESTI STANDARD EVS-EN 15182-1:2007 Hand-held branchpipes for fire service use - Part 1: Common requirements Hand-held branchpipes for fire service use - Part 1: Common requirements EESTI STANDARDIKESKUS

More information

ISO INTERNATIONAL STANDARD. Welding Acceptance inspection of electron beam welding machines Part 4: Measurement of welding speed

ISO INTERNATIONAL STANDARD. Welding Acceptance inspection of electron beam welding machines Part 4: Measurement of welding speed INTERNATIONAL STANDARD ISO 14744-4 First edition 2000-04-15 Welding Acceptance inspection of electron beam welding machines Part 4: Measurement of welding speed Soudage Essais de réception des machines

More information

ISO 1806 INTERNATIONAL STANDARD. Fishing nets Determination of mesh breaking force of netting

ISO 1806 INTERNATIONAL STANDARD. Fishing nets Determination of mesh breaking force of netting INTERNATIONAL STANDARD ISO 1806 Second edition 2002-12-01 Fishing nets Determination of mesh breaking force of netting Filets de pêche Détermination de la force de rupture de la maille de nappe de filet

More information

Fire Safety. Presenter, Kevin V Coleman September 14 th 2016

Fire Safety. Presenter, Kevin V Coleman September 14 th 2016 Fire Safety Presenter, Kevin V Coleman September 14 th 2016 Fire is a significant risk WHAT IS FIRE? To start or continue to burn, a fire requires: Heat; Fuel (Combustible materials); Oxygen. This is known

More information

STT 3000 Series STT250 /150 Surge Protection Device Specifications

STT 3000 Series STT250 /150 Surge Protection Device Specifications STT 3000 Series STT250 /150 Surge Protection Device Specifications Part Number: 46188660-501 EN2I-6061 June 2011 Introduction This device is designed to give the Smart Temperature Transmitter maximum protection

More information

Special solution KS marine. Kitchen protection system KS marine Fire prevention for galleys

Special solution KS marine. Kitchen protection system KS marine Fire prevention for galleys Special solution KS 2000-8 marine Kitchen protection system KS 2000-8 marine Fire prevention for galleys RiskDeep fat fryer fire Safety requirements for passengers and crew are especially high at sea.

More information

AutoM Click to go to the page. AutoM Auto Shaker Filter

AutoM Click to go to the page. AutoM Auto Shaker Filter AutoM.0111.4 Click to go to the page AutoM Auto Shaker Filter The Auto M (500-6,500 CFM) Suitable for various applications that generate light to medium volumes of dry dust ATEX Compliant Applications:

More information

BFD Light Curtains The new choice for cutting edge safety for industrial doors

BFD Light Curtains The new choice for cutting edge safety for industrial doors BFD Light Curtains The new choice for cutting edge safety for industrial doors The BFD Series light curtains are designed specifically for the industrial door market, as they provide a new safety sensor

More information

Gillelejevej 30b DK-3230 Graested Tel.: Fax: Member of the NIBE Group

Gillelejevej 30b DK-3230 Graested Tel.: Fax: Member of the NIBE Group Gillelejevej 30b DK-3230 Graested Tel.: +45 48 39 88 88 - Fax: +45 48 39 88 88 info@san-as.com - www.san-as.com Member of the NIBE Group A bit of history... SAN Electro Heat a/s - previously Svend A. Nielsen

More information

Custom Engineered Design. English

Custom Engineered Design. English Custom Engineered Design English Why Choose Elfab? As Europe s leading manufacturer of Bursting Discs, Elfab s expertise in developing custom engineered solutions has been applied to a diverse range of

More information

HazLoc Essential Guides:

HazLoc Essential Guides: HazLoc Essential Guides: Intertek Deeside Lane, Chester, CH1 6DD UK hazloc@intertek.com +44 1244 882590 www.intertek-hazloc.com Contents Contents... 1 Introduction... 1 Introduction to Ex... 1 ATEX Overview...

More information