SAFEGUARD YOUR HOME WITH QUELL
|
|
- Octavia Magdalene Leonard
- 6 years ago
- Views:
Transcription
1
2 THE INCONVENIENT TRUTH ABOUT HOUSEHOLD FIRES Australian law mandates that all residences have at least one smoke alarm installed on each level of the home and for good reason. Fire represents a serious hazard to people, property and the environment. In Australia, approximately 115 people die and 3,000 sustain injuries from structure fires annually. Many of the deaths and injuries recorded annually are preventable and Quell is committed to reducing these figures through smart technology and education initiatives. SAFEGUARD YOUR HOME WITH QUELL
3 KEEPING AUSTRALIA SAFE FOR OVER 100 YEARS Quell is the consumer division of Chubb, one of the market leaders in fire safety equipment boasting over 100 years experience in Australia. Quell produces a comprehensive range of user friendly and competitively priced smoke alarms, fire extinguishers, fire blankets and home and personal safety products that set the benchmark for fire prevention, detection and protection. All Quell fire safety products are the result of tireless research and development and are submitted to comprehensive testing before going to market. SAFEGUARD YOUR HOME WITH QUELL
4 COLOUR CODED CONVENIENCE KITCHEN HALLWAY LIVING AREA CO [ CARBON MONOXIDE ] Shopping for fire safety products has never been easier. Quell s colour coding system neatly categorises our range of smoke alarms, fire extinguishers, fire blankets, home fire safety kits. HOME GARAGE WORKSHOP BEDROOM MARINE INDUSTRIAL AUTO VEHICLE SAFEGUARD YOUR HOME WITH QUELL
5 SMOKE ALARMS FIRE BLANKETS FIRE EXTINGUISHERS FIRE SAFETY KITS
6 Quell smoke alarms use two main sensor types to detect fires in residential environments: ionisation and photoelectric. Photoelectric sensors are capable of detecting the larger smoke particles produced by burning foam, rubber and synthetic materials. Ionisation sensors are suitable for detecting burning paper, wood and flammable liquids. WARRANTY Quell also manufacture alarms specifically designed to detect the presence of carbon monoxide in the atmosphere. It is important that you consider your home environment and choose the right alarm for your room. Australian Standard AS 3786 Lic1377 SAI Global SMOKE ALARMS All Quell smoke alarms are certified to Australian Standard AS 3786.
7 IONISATION MODEL: Q946 PART NO: V Alkaline battery Test button Hush button Low battery warning alert 10 year warranty on alarm unit (excludes battery) Certified to Australian Standards AS 3786 ActivFire Listed LIVING AREA SMOKE ALARMS
8 IONISATION 2 PACK HUSH/TEST MODEL: Q946 PART NO: V Alkaline battery Test button Hush button Low battery warning alert 10 year warranty on alarm unit (excludes battery) Certified to Australian Standards AS 3786 ActivFire Listed LIVING AREA SMOKE ALARMS
9 DUAL SENSOR IONISATION / PHOTOELECTRIC MODEL: QPI9010 PART NO: Test / reset button - tests alarm circuitry and horn Hush button Low battery warning alert A red LED flashes every 45 seconds to indicate optimal battery life The dual sensors detect all fire types 10 year warranty on alarm unit (excludes battery) Certified to Australian Standards AS 3786 ActivFire Listed LIVING AND HALLWAY SMOKE ALARMS
10 240V AC/DC PHOTOELECTRIC WITH HUSH 9V BATTERY MODEL: Q1300 PART NO: LIVING AND HALLWAY SMOKE ALARMS Test button Hush button Low battery warning alert 240V mains powered with 9V battery backup Connect to up to 24 additional smoke alarm units Dual LED indicator green indicates 240V power source; flashing red indicates alarm activation/battery expiration 10 year warranty on alarm unit only (excludes battery) Certified to Australian Standards AS 3786 ActivFire Listed
11 PHOTOELECTRIC HUSH 9V LITHIUM 10YR SEALED L/L BATTERY MODEL: Q1400 PART NO: Low battery warning alert indicates alarm is in need of replacement Easy to use test/hush button Test at reduced volume Bug screen prevents insect infiltration Non removable sealed lithium batteries No wiring required 10 year warranty on alarm unit (excludes battery) Certified to Australian Standards AS 3786 ActivFire Listed LIVING AND HALLWAY SMOKE ALARMS
12 PHOTOELECTRIC HUSH/TEST MODEL: Q301 PART NO: Test button Hush button 9V battery 10 year warranty on alarm unit (excludes battery) Certified to Australian Standards AS 3786 ActivFire Listed BEDROOM AND HALLWAY SMOKE ALARMS
13 PHOTOELECTRIC 2PK HUSH/TEST MODEL: Q301 PART NO: Test button Hush button 9V battery 10 year warranty on alarm unit (excludes battery) Certified to Australian Standards AS 3786 ActivFire Listed BEDROOM AND HALLWAY SMOKE ALARMS
14 PHOTOELECTRIC HUSH/TEST MODEL: Q301 PART NO: Test button Hush button 9V battery 10 year warranty on alarm unit (excludes battery) Certified to Australian Standards AS 3786 ActivFire Listed KITCHEN ALARMS
15 CARBON MONOXIDE ALARMS Carbon monoxide (CO) alarms detect the early presence of carbon monoxide emitted from gas sources such as heating and cooking systems, vehicle engines, fuels and blocked chimneys. CO alarms are intended to supplement conventional smoke alarms, not replace them. A CO alarm is not a smoke alarm and, therefore, will not satisfy legal requirements regarding the installation of smoke alarms in the home. WARRANTY Ideal for use in domestic premises such as bedrooms, living areas and caravans, motor homes and boats. CARBON MONOXIDE ALARMS
16 CARBON MONOXIDE DIGITAL DISPLAY ALARM MODEL: PD04 PART NO: Test/reset button 3 x AA batteries included Battery powered Easy to fit no wiring required 10 year warranty on alarm (excludes battery) KITCHEN ALARMS
17 FIRE BLANKETS Fire blankets may be used to extinguish small cooking fires and clothing fires. Quell s fire blankets are durable, easy to use and comply with Australian Standard AS/NZS Fire blankets may only be used once and should be disposed of after use. Easily mounted - suitable for hanging inside of cupboard door Quick release tabs Comes in storage pouch WARRANTY Australian Standard AS/NZS 3504 Lic2183 SAI Global FIRE BLANKETS
18 1M X 1M - PART NO: Comes in storage pouch inside clamshell packaging Easily mounted suitable for hanging inside cupboard door Quick release tabs Fire types stove top and clothing fires 1.2 X 1.8M - PART NO: Comes in storage pouch inside clamshell packaging Easily mounted suitable for hanging inside cupboard door Quick release tabs Fire types greater surface area suited to stove top and adult clothing fires FIRE BLANKETS * Both fire blankets are ideal for kitchens, caravans and boats
19 Quell s dry powder fire extinguishers are suited to a range of household applications. ALL QUELL FIRE EXTINGUISHERS FEATURE: Quality brass valve and metal handle Easy to read pressure gauge Complies with Australian Standard AS 1841 WARRANTY Australian Standard AS Lic25536 SAI Global FIRE EXTINGUISHERS
20 1KG KITCHEN/GARAGE PART NO: High strength full body mounting bracket with quick release locking strap Fire types cooking fat and oil fires, flammable liquid fires and electrical based fires Fire rating 10B:E 1KG HOME/VEHICLE/MARINE PART NO: High strength full body mounting bracket with quick release locking strap Fire types wood, paper and cloth, flammable liquid fires and electrical based fires Fire rating 1A:10B:E FIRE EXTINGUISHERS
21 1KG AUTO/MARINE PART NO: Metal mounting bracket with twin spring release (release locking straps which meets CAMS requirements.) Fire types wood, paper and cloth, flammable liquid fires and electrical based fires Fire rating 1A:10B:E 1KG TWIN PACK (KITCHEN/GARAGE AND HOME/VEHICLE) PART NO: FIRE EXTINGUISHERS Fire types wood, paper and cloth, flammable liquid fires and electrical based fires
22 1.5KG HOME/GARAGE/WORKSHOP PART NO: Heavy duty metal mounting bracket with spring release locking strap Fire types wood, paper and cloth, flammable liquid fires and electrical based fires Fire rating 2A:30B:E 2.3KG HOME/GARAGE/WORKSHOP PART NO: Complete with hose assembly Metal wall mounting bracket Fire types wood, paper and cloth, flammable liquid fires and electrical based fires Fire rating 2A:40B:E FIRE EXTINGUISHERS
23 4.5KG INDUSTRIAL PART NO: Metal wall mounting bracket Fire types wood, paper and cloth, flammable liquid fires and electrical based fires Fire rating 4A:60B:E SUITABLE FOR USE ON: Electrical switchboards Commercial buildings Manufacturing plants Homes and garages FIRE EXTINGUISHERS
24 A Quell fire safety kit gives you the basics to safeguard your home or car. It is important that you acquaint yourself with how to use your fire safety equipment and establish processes to be followed in the event of a fire. SMALL HOME FIRE SAFETY KIT PART NO: kg Extinguisher (Home / Vehicle / Marine) Fire blanket 1x1m FIRE SAFETY KITS LARGE HOME FIRE SAFETY KIT PART NO: kg Extinguisher (Home / Vehicle / Marine) Fire blanket 1x1m Ionisation Smoke Alarm Photoelectric Smoke Alarm
25 DIFFERENT SENSORS FOR DIFFERENT FIRES Photoelectric sensors detect the types of fires that can smoulder for hours before bursting into flames whereas ionisation sensors are designed to detect fast flaming fires. Fire safety experts recommend installing both types in a residential environment. FIRE SAFETY TIPS Fire alarms should be replaced every 10 years. Refer to the expiry date on the bottom of your alarm. Replace your battery once a year (does not apply to sealed lithium nonremovable batteries). We advise replacing your batteries when daylight saving begins so you don t forget (Does not apply to 10-year lithium battery powered alarms.) Areas to avoid when installing near ceiling fans and air conditioners and bathrooms, garages, near furnaces and/or water heaters. Clean and vacuum your smoke alarm at least every 6 months to prevent dust build up that can cause nuisance activations. Never paint your smoke alarm.
26 QUELL FIRE SAFETY PRODUCTS Quell manufactures a range of quality products designed to keep Australians safe. With a product range that includes smoke alarms, fire extinguishers, fire blankets and fire safety kits, Quell has you covered in the safety department. Products are available Australia wide from leading retailers. STOCKISTS
27 CHUBB FIRE & SECURITY PTY LTD ABN UTC Building and Industrial Systems Milton St, Ashfield NSW 2131 TEL: Chubb is part of UTC Building & Industrial Systems, a unit of United Technologies Corp. Quell is a registered trademark of Chubb Fire & Security Pty Ltd. Copyright 2015 Chubb Fire & Security Pty Ltd CONTACT
_V1.qxd:_ :27 AM. Ionisation Sealed Smoke Alarm with Ten Year Lithium Battery & Hush. Manual. Model Q910
Ionisation Sealed Smoke Alarm with Ten Year Lithium Battery & Hush Manual Model Q910 Ionisation smoke alarms are designed to detect invisible particles (associated with fast flaming fires). Home fires
More informationSMOKE & CARBON MONOXIDE ALARMS
SMOKE & CARBON MONOXIDE ALARMS COMBINATION SMOKE & CARBON MONOXIDE ALARMS SMOKE ALARMS CARBON MONOXIDE ALARMS Partners in Safety with Kidde... WORRY-FREE 10 YEAR SEALED-IN BATTERY FAST Parts Division of
More informationSmoke & Carbon Monoxide Alarms
Smoke & Carbon Monoxide Alarms Combination Smoke and Carbon Monoxide Alarms Smoke Alarms Carbon Monoxide Alarms Partners in Safety with Kidde... Worry-Free 10 Year Sealed-In Battery page 2 Kidde Product
More informationONLY WORKING SMOKE ALARMS SAVE LIVES
okealarmdl_feb2011.indd 1 ONLY WORKING SMOKE ALARMS SAVE LIVES 17/02/11 12:1 Smoke alarm facts If you don t have a working smoke alarm installed in your home, and a fire occurs: You are 57% more likely
More informationSmoke Alarms. Clipsal FireTek. Photoelectric Smoke Alarms. clipsal.com/smokealarms
Clipsal FireTek Smoke Alarms Photoelectric Smoke Alarms clipsal.com/smokealarms Iconic and Clipsal Iconic are trademarks of Schneider Electric (Australia) PTY Limited. 2 clipsal.com/smokealarms Your customers
More informationFireTek : Easier installation. Superior performance.
1/10/2018 Smoke Alarms - Clipsal by Schneider Electric FireTek : Easier installation. Superior performance. Clipsal FireTek Smoke Alarms deliver dependable safety, with subtle style to complement any interior
More informationSMOKE/CARBON MONOXIDE DETECTOR REQUIREMENTS
HOMES BUILT PRIOR TO JANUARY 1, 1975 WITH NO RENOVATIONS As of December 1, 2016, upon sale or transfer Must be located on every level of the residence Must be located on the ceiling at the base of each
More informationFire Safety Prices include 20% Subject to availability. Prices may vary Pictures and specifications are a guide only
Fire Safety 2017 Prices include VAT @ 20% Subject to availability. Prices may vary Pictures and specifications are a guide only West Street Somerton Somerset TA11 7PS Fax: 01458 274010 Email: info@overtlocke.co.uk
More informationCarbon Monoxide Alarms Smoke and Carbon Alarms Upgrade Requirements for Single and Two Family Dwellings
Planning and Building Department INFORMATIONAL GUIDE Updated: 2017 July 31 Smoke Alarms This brochure explains the requirements for smoke alarms in new or renovated buildings. It provides information to
More informationSmoke alarm Installer s Manual
Smoke alarm Installer s Manual 240V Interconnectable Main Operated Alarm For models: Q1300 Thank you for purchasing Quell 240V hard-wired photoelectric smoke alarm. Please read through our guide in full.
More informationSmoke Alarm User s Guide
10Y29 For model: 10Y29 Smoke Alarm User s Guide Lithium (non-replaceable sealed in) Battery-Operated Optical Smoke Alarm with HUSH TM Control to temporarily silence nuisance alarms. Thank you for purchasing
More informationSmoke Alarm User s Manual
V-MUL-007-D(A0) Smoke Alarm User s Manual Please read and save this manual PHOTOELECTRIC SMOKE ALARM( HUSH FEATURE) MODEL: VST-S588H Class II Apparatus Photoelectric smoke alarms are generally more effective
More informationfrom the world leaders manufacturing over 35 million smoke, heat and carbon monoxide alarms every year
Cl/SfB (68.52) Uniclass L7625 September 2012 A UTC Fire & Security Company Your one-stop solution for hard-wired and sealed-in battery smoke and CO alarms from the world leaders manufacturing over 35 million
More informationSmoke Alarms and Carbon Monoxide Alarms
70 N 1st Street Campbell, California 95008 Phone (408) 866-2130 Fax (408) 871-5101 Smoke Alarms and Carbon Monoxide Alarms March, 2018 When building permits are issued for additions, alterations or repairs
More informationMFES READY Make your home fire safe. Home Smoke Alarms
MFES READY Make your home fire safe Home Smoke Alarms Working smoke alarms keep you and your family safe. It s the law and it could save your life and the lives of your loved ones. Are you READY to Make
More informationNationalFireEquipmentLtd.
NationalFireEquipmentLtd. Worry-FreeACWire-inCombinationSmoke& Carbon Monoxide(CO)Alarm SealedLithium BateryBackup ArchitecturalandEngineering Specifications InstalationofSmokeAlarm Thecombinationsmokeandcarbonmonoxidealarm
More information_V4:_ :28 AM Page 1. For model 29D,29HD. Photoelectric Smoke Alarm. User Guide
0306-7210-02_V4:_ 2015.3.13 9:28 AM Page 1 For model 29D,29HD Photoelectric Smoke Alarm User Guide For 9 Volt Battery Operated Smoke Alarm Thank you for purchasing this smoke alarm. It is an important
More informationw w a. m o c. x e r fi. w u
1300 246 247 www.firex.com.au sales@firex.com.au Contents 1. About Firex 03 2. Fire Extinguishers 04 3. Fire Hose Reels 10 4. Fire Blankets 11 5. Accessories 12 6. Extinguisher Spare Parts 16 7. Fire Cabinets
More informationSmoke & Carbon Monoxide
A Guide to the Massachusetts Smoke & Carbon Monoxide Requirements when Selling a Oneor Two-Family Residence FIRE SERVICES Department of Fire Services PO Box 1025 Stow, MA 01775 978-567-3300 www.mass.gov/dfs
More informationFrequently Asked Smoke Alarm Questions
Frequently Asked Smoke Alarm Questions Why should my home have smoke alarms? Most fire deaths are caused by smoke not flames. Most fire deaths and injuries occur between midnight and 8 a.m. when people
More informationSmoke Alarm Legislation
THE REQUIREMENT FOR SMOKE ALARMS Is it law for residential properties to have mains powered smoke alarms installed? The Building Regulations 2012 require owners to install compliant mains powered smoke
More informationB16008-R0-160RC SERIES-U&C 17/1/07 11:13 AM Page Installation Guide
B16008-R0-160RC SERIES-U&C 17/1/07 11:13 AM Page 1 1.1 Installation Guide 2 SCREWDRIVER INTO S & PUSH COVER AWAY B16008-R0-160RC SERIES-U&C 17/1/07 11:13 AM Page 2 2. ALARM REMOVAL LOCATE REMOVAL SLOT
More informationDatasheet for Models: 1SFWR 1SFW. NEW range. capability. 230V Mains Fast-Fit Ionisation Smoke Alarms. Key Features. Applications
Datasheet for Models: 1SFWR 1SFW NEW range Developed specifically for social and private housing, Slick is the only range of fast-fit rechargeable ionisation and optical smoke alarms, and heat alarms guaranteed
More informationCAVIUS NANO LIMITED. 8 King Street, Te Puke 3119 Bay of Plenty, New Zealand. PO Box 11241, Papamoa 3118 Bay of Plenty, New Zealand
CAVIUS NANO LIMITED Address: 8 King Street, Te Puke 3119 Bay of Plenty, New Zealand Postal Address: PO Box 111, Papamoa 3118 Bay of Plenty, New Zealand 0800 766 533 info@cavius.co.nz www.cavius.co.nz CONTENTS
More informationSmoke Alarm and Carbon Monoxide Alarm Installation
Smoke Alarm and Carbon Monoxide Alarm Installation 2014 1 Protocol Before Installing the Alarm Make sure the resident signs the contract located in the packet. Senior citizens are considered to be those
More informationSI-610 / SO-610 User Manual. 10 Year Smoke Alarm Standard / Toast Proof with Smart Silence
SI-610 / SO-610 User Manual 10 Year Smoke Alarm Standard / Toast Proof with Smart Silence INTRODUCTION 2 AUTOMATIC POWER ENGAGE 2 SENSOR TECHNOLOGY 3 APPLICATION 4 POSITIONING 7 LIMITATIONS 9 HOW TO INSTALL
More informationOUT CARBON DIOXIDE (CO2) EXTINGUISHER Certified & Approved to AS/NZS Lightweight Aluminium Cylinder. AS High pressure hose assembly with
OUT DRY POWDER EXTINGUISHERS - AB:E Certified & Approved to AS/NZS 1841.5 Deep drawn steel cylinder with welded base and robust skirt., giving extra resistance to standard corrosive environments together
More informationFIREWORLD DRY POWDER ABE FIRE EXTINGUISHERS
- 1 - WORLD DRY POWDER ABE EXTINGUISHERS Certified & Approved to AS/NZS 1841.5 Fireworld Deep drawn steel cylinder with welded base and robust skirt., giving extra resistance to standard corrosive environments
More information2 BURNER LP GAS STOVE OPERATING INSTRUCTIONS
BURNER LP GAS STOVE OPERATING INSTRUCTIONS Part No. 5090 IMPORTANT Read these instructions for use carefully. Familiarise yourself with the appliance before connecting it to it s gas container. Keep these
More informationSmoke Alarm User Manual
Smoke Alarm User Manual Model number: GS528A Ref:ST528A Thank you for purchasing our smoke alarm. Please take a few minutes to read the user s manual thoroughly and familiarize yourself and your family
More informationPRODUCT GUIDE & INFORMATION. Professional Fire & Carbon Monoxide Solutions
PRODUCT GUIDE & INFORMATION Professional Fire & Carbon Monoxide Solutions 1 Nearly 50 years experience of designing, manufacturing and supplying home safety products, makes BRK an industry leader. We believe
More information10 YEAR LIFE SMOKE ALARM 10 YEAR LIFE TOAST PROOF SMOKE ALARM
User Manual 10 YEAR LIFE SMOKE ALARM SI-610 10 YEAR LIFE TOAST PROOF SMOKE ALARM SO-610 Please read me as I could save your life. Please retain this user manual for future reference CONTENTS INTRODUCTION
More informationCarbon Monoxide Safety Information
Aurora Fire Rescue City of Aurora Fire Administration 15151 E. Alameda Parkway, Suite 4100 Aurora, Colorado 80012 303.326.8999 Worth Discovering auroragov.org Carbon Monoxide Safety Information Aurora
More informationESCAPE LIGHT SMOKE ALARM LSI-601 ESCAPE LIGHT TOAST PROOF SMOKE ALARM LSO-601
User Manual ESCAPE LIGHT SMOKE ALARM LSI-601 ESCAPE LIGHT TOAST PROOF SMOKE ALARM LSO-601 Please read me as I could save your life. Please retain this user manual for future reference INTRODUCTION CONTENTS
More informationWIRELESS PHOTOELECTRIC SMOKE ALARM
USER S MANUAL MODEL: VST-WS588IH IMPORTANT! PLEASE READ CAREFULLY AND SAVE. This user s manual contains important information about your Alarm s operation. If you are installing the Alarm for use by others,
More informationPLEASE READ THIS USER GUIDE CAREFULLY
PLEASE READ THIS USER GUIDE CAREFULLY Cavius DIY Smoke Alarm Model 2008-002 / 10012 / 10013 / 10014 Manufactured by CAVIUS PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE
More informationPLEASE READ THIS USER GUIDE CAREFULLY
PLEASE READ THIS USER GUIDE CAREFULLY Cavius DIY Smoke Detector Model 2006-001 Manufactured by CAVIUS PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE. For large text
More informationNational Fire Authority
National Fire Authority GUIDELINE SELECTION, INSTALLATION & MAINTENANCE OF PORTABLE FIRE EXTINGUISHERS AND FIRE BLANKETS. First Issued: 15 October, 2007 Version No: 1 Guideline No: GL-01 Prepared By: Structural
More informationWireless Interlink Smoke Alarm + 10 Year Life
User Manual Wireless Interlink Smoke Alarm + 10 Year Life WST-630 Please retain this user manual for future reference 1 CONTENTS Introduction 3 Sensor technology 3 Application 3 Positioning 4 How to install
More informationFire fighting Questions
Fire fighting Questions Question 1 (1 Mark) The sides and base of the fire tetrahedron are: a. fuel, nitrogen, oxygen, chemical reaction b. fuel, oxygen, heat, chain reaction c. heat, oxygen, nitrogen,
More informationPRESTO DRY POWDER FIRE EXTINGUISHERS - AB:E
- 1 - PRESTO DRY POWDER EXTINGUISHERS - AB:E Certified & Approved to AS/NZS 1841.5 Deep drawn steel cylinder with welded base and robust skirt., giving extra resistance to standard corrosive environments
More informationLSI-601 / LSO-601 User Manual. Smoke Alarm Standard / Toast Proof with Ultra Bright Escape Light
LSI-601 / LSO-601 User Manual Smoke Alarm Standard / Toast Proof with Ultra Bright Escape Light INTRODUCTION 2 BLUESCAPE ULTRA BRIGHT TECHNOLOGY 2 SENSOR TECHNOLOGY 3 APPLICATION 3 POSITIONING 6 LIMITATIONS
More informationPORTABLE FIRE EXTINGUISHERS. Fire Safety.
WHAT THE RATINGS MEAN: The New Zealand Standard for classifiying, rating, and performance testing of Fire Extinguishers (AS/NZ1850:1997), was introduced at the request of manufacturers, who wanted a method
More informationINSTALLATION AND USER MANUAL
1399-7201-00_V4:_ 2012.6.8 10:39 AM Page 1 MODEL LIF5800RF INSTALLATION AND USER MANUAL FLUSH DESIGN PHOTO-ELECTRIC SMOKE ALARM 240VAC MAINS POWERED SINGLE STATION AND/OR INTERCONNECTABLE (24 UNITS) PHOTO-ELECTRIC
More informationHome Fires Are Common, Deadly and Preventable
Home Fires Are Common, Deadly and Preventable Fire safety probably isn t high on the list of concerns for buyers when they purchase a home. But the statistics indicate that it should be. According to the
More informationFor your convenience, write down the following information. If you call our Consumer Hotline, these are the first questions you will be asked.
PHOTOELECTRIC SMOKE AND FIRE ALARM USER S GUIDE MODEL PE9 9 Volt Battery Operated Photoelectric Smoke Alarm Thank you for purchasing this Fyrnetics smoke and fire alarm. It is an important part of your
More information169MHz Telecare Devices Carbon Monoxide Detector
169MHz Telecare Devices Carbon Monoxide Detector Compatible with Reach at home alarms, Advent xt warden call, Altec Response and Touchsafe Pro Nursecall systems CO alarm activates on Time Weighted Average;
More informationAir Purification System. Instruction Book CLI-AP20
Air Purification System Instruction Book CLI-AP20 by Contents 2 Cli-Mate Recommends Safety First 6 Components 7 Functions 10 Care & Cleaning 11 Troubleshooting CLI-MATE RECOMMENDS SAFETY FIRST At Cli-Mate
More informationINSTALLATION AND USER MANUAL
1299-7201-01:_ 2014.5.7 10:40 AM Page 1 MODEL HG1000 INSTALLATION AND USER MANUAL SMOKE ALARM IONISATION DESIGN 240VAC MAINS POWERED SINGLE STATION AND/OR INTERCONNECTABLE (24 UNITS) IONISATION SMOKE ALARM.
More informationHOME FIRE SAFETY. Reference Guide
HOME FIRE SAFETY Reference Guide 1 CONTENTS Smoke Alarms 101 1 Home Fire Escape Planning 4 Fire Extinguishers 6 Carbon Monoxide 8 SMOKE ALARMS 101 Did you know? Having a smoke alarm cuts your risk of dying
More informationCan I Interconnect Smoke Alarms and Carbon Monoxide (CO) Alarms?
Can I Interconnect Smoke Alarms and Carbon Monoxide (CO) Alarms? Only BRK Brands, Inc. CO alarms or Smoke/CO combo alarms with a "smart interconnect" feature should be interconnected with compatible smoke
More information2014 Alberta Building Code. Part 9 changes relating to Smoke and CO Alarms
2014 Alberta Building Code Part 9 changes relating to Smoke and CO Alarms 9.32.3.9 Carbon Monoxide Alarms What has not changed: 4) & 6) In a residential occupancy containing a fuel burning appliance or
More information½ CAUTION ½ DANGER. Getting to know the smoke detector. ARGUS Smoke Detector Single. Accessories. Operating instructions. For your safety A B C D E
Schneider-Electric 2014EAV56178-0102/15 en Getting to know the smoke detector Scope of supply ARGUS Smoke Detector Single Operating instructions Art. no. MEG5470-2119 Accessories Sealing pin for ARGUS
More informationFire precautions in dwellings
NORWICH City Council Fire precautions in dwellings Private sector housing Providing homes building communities Version 2 Published by Norwich City Council June 2010 Contents Page Introduction 1 2 Types
More informationPLEASE READ THIS USER GUIDE CAREFULLY
PLEASE READ THIS USER GUIDE CAREFULLY Cavius DIY Heat Alarm Model 3002-TK001 Manufactured by CAVIUS PLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE. For large text option
More informationM-5628-PI PI: SEP 2018 M (1)
M-5628-PI-145491 PI: SEP 2018 M5628-01 (1) 4 97 KEEP OUT DRAFTS and save money too 17' x 5/16" Rubber Weatherstrip Tape 1/4" thick, gray or brown 288659 288632 288640 2 37 Clear Weatherseal Tape 2" W.
More informationSmoke Alarm User Manual
Typical single storey dwelling with recommended: Install a smoke on the ceiling inside each bedroom and in the hallway outside each separate sleeping area. If a bedroom area hallway is more than 30 feet
More informationR32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT
SWING LRSWING Installation Manual Split Type Wall Mounted Air Conditioner COOL RUN C SPEED TURBO ON/OFF FAN COOL HEAT SWING SWING Rinnai Systems Models System Indoor Outdoor HSNRQ25B HINRQ25B HONRQ25B
More informationFire Safety and Whole Home Protection
PRODUCT CATALOGUE Distribution Partner Fire Safety and Whole Home Protection SMOKE AND FIRE FACTS CHOOSING THE RIGHT ALARM First Alert, one of the most recognized safety brands in Canada, offers an array
More informationSmoke Alarms Save Lives.
Smoke Alarms Save Lives. U.S. Fire Administration Mission Statement We provide national leadership to foster a solid foundation for local fire and emergency services for prevention, preparedness and response.
More informationNCEHSA Conference. Carbon Monoxide Detector Regulations for Lodging Establishments (S.L )
NCEHSA Conference Carbon Monoxide Detector Regulations for Lodging Establishments (S.L. 2013-413) 1 Purpose of this session The purpose of this session is to review the provisions of Session Law 2013-413
More informationFirst Alert Smoke Alarm Beeping Every 30 Seconds
First Alert Smoke Alarm Beeping Every 30 Seconds When it comes to your safety, sometimes you need more than just a beep or You'll also get an alert on your phone or tablet (as long as your Protect has
More informationSPECIALIST IN FIRE SAFETY PRODUCTS PRODUCT GUIDE
PRODUCT GUIDE 1.0KG MEGAFIRE ABE RATING 1A:20B:E ME11ABE 3.6MM 1.0KG 1.0KG 1.8KG WORKING PRESSURE: 1000KPA AT 23 C 90MM 265MM 25668-DC-6321 NICKEL PLATED 8 SECONDS MegaFire s compact 1.0KG extinguisher
More informationRequirements for Smoke / Carbon Monoxide / Fire Extinguisher Certification
Requirements for Smoke / Carbon Monoxide / Fire Extinguisher Certification In order to successfully pass the inspection, your property will need to meet all regulations mandated by the state and municipality.
More informationUSER MANUAL 10 YEAR LIFE SMOKE ALARM
USER MANUAL 10 YEAR LIFE SMOKE ALARM 17 0086 EN 14604:2005+AC: 2008 Smoke alarm devices DOP: SADOPST-750-01 BS EN 14604: 2005+AC: 2008 Licence No: KM557789 GN4681R1 ST-750 Sprue Safety Products Ltd. Vanguard
More informationPOWER COOKER & STOCKPOT SET Instruction Manual Part No. COMP7012
POWER COOKER & STOCKPOT SET Instruction Manual Part No. COMP7012 IMPORTANT Read these instructions for use carefully. Familiarise yourself with the appliance before connecting it to its gas container.
More informationHeat Alarm User s Manual
V-MUL-009-A(A0) Heat Alarm User s Manual Please read and save this manual FIXED TEMPERATURE HEAT ALARM MODEL: VST-H598I Class II Apparatus Heat alarms are ideal for kitchen, garages, basements, boilers
More informationSmoke Alarm with RF Interlink User Guide
Smoke Alarm with RF Interlink User Guide Model LIF10YPEW Lithium (non-replaceable sealed in) Battery-Operated Photoelectric Smoke Alarm with wireless RF Interlink and HUSH Control You do NOT need a home
More informationPLEASE READ THE USER GUIDE CAREFULLY BEFORE INSTALLATION AND RETAIN FOR FUTURE USE.
OPTICAL SMOKE ALARM DEVICE Commercial reference: 2103-002 Developed by CAVIUS The smoke alarm is designed for private homes, camping trailers, mobile homes and caravans. It is not recommended for boats.
More informationMelrose Fire Department
Melrose Fire Department Office of Fire Prevention Re: 9/20/18 Guidelines for the Type and Placement of Smoke and Carbon Monoxide Alarms Purpose of this guide is to help homeowners protect their homes and
More informationFrequently Asked Carbon Monoxide Questions
Frequently Asked Carbon Monoxide Questions What is carbon monoxide? It is an invisible, odorless, colorless gas created when fuels, such as gasoline, wood, charcoal, coal, natural gas, propane, oil, kerosene,
More informationTEXAS A&M UNIVERSITY EMERGENCY MANAGEMENT. Home Safety. Smoke Alarms
Smoke Alarms If you have a fire, smoke alarms can cut nearly in half your risk of dying in a fire. Smoke alarms sense abnormal amounts of smoke or invisible combustion gases in the air. They can detect
More informationLIFESAVER MODEL SL240 REMOTE VISUAL SIGNALLING DEVICE (STROBE LIGHT)
LIFESAVER MODEL SL240 REMOTE VISUAL SIGNALLING DEVICE (STROBE LIGHT) USER MANUAL AUSTRALIAN ELECTRICAL AUTHORITY CS96313V IMPORTANT! READ ALL INSTRUCTIONS BEFORE INSTALLATION AND LEAVE THIS MANUAL FOR
More informationWok Cookers Instruction Manual
Wok Cookers Instruction Manual Part No. DC100-09 Single Burner Wok Cooker Part No. DC200-09 Double Burner Wok Cooker IMPORTANT It is IMPORTANT that you read these instructions carefully and understand
More information2 BURNER STOVE WITH GRILL
9 OWNERS MANUAL OWNERS MANUAL 2 BURNER STOVE WITH GRILL Part No. COMP546 IMPORTANT: Read these instructions for use carefully. Familiarise yourself with the appliance before connecting it to a gas container.
More information2/ $ 5 SAVE $7. Friendly Place. Serious Service. Painter s Touch 2X Ultra Cover Paint + Primer Spray Paint. Turf Builder
Friendly Place. Serious Service. 2/ 5 Painter s Touch 2X Ultra Cover Paint + Primer Spray Paint 12 oz. Gloss black or white 777537 778400 15 Turf Builder 97 WinterGuard Fall Lawn Food 5,000 sq. ft. coverage
More informationSmoke Alarm User s Guide
i9010 For model: i9010 Smoke Alarm User s Guide Lithium (non-replaceable sealed in) Battery-Operated Smoke Alarm with Alarm Memory and SMART HUSH TM Control to temporarily silence nuisance alarms. Thank
More informationFrom Your Building Inspector
The Sound of Safety What is the most important thing to remember when installing a smoke alarm or carbon monoxide alarm? Location, location, location! Smoke Alarm Safety: Install at least one smoke alarm
More information_EN_V4:_ :46 AM Page 1 USER S MANUAL 0086-CPD
1227-7201-00_EN_V4:_ 2012.3.29 9:46 AM Page 1 USER S MANUAL KF1 KF1R Ionisation KF2 KF2R Optical EN 14604:2005 LICENSE NO. KM 524754 0086-CPD-535595 12 PLEASE READ AND SAVE INSTALLER: Please leave this
More informationPhotoelectric Smoke Alarm
Photoelectric Smoke Alarm DTCTSL40WT DTCTSL40WT_PhotoelectricSmokeAlarm_Manual 1 English Content Introduction Overview Product Details Detailed Users Guide Document revision history Customer support details
More informationPLAN NOW!! Plan your escape today Your life may depend on it tomorrow HOME ESCAPE PLAN EXERCISE
PLAN NOW!! FAMILY ACTIVITY HOME ESCAPE PLAN EXERCISE Anyone who has lived through a fire will tell you how terrifying it is. Sadly, sometimes people don t live to talk about it. We know, because we see
More informationMODEL SS-901 EARLY WARNING PHOTOELECTRIC SMOKE & FIRE ALARM READ ALL INSTRUCTIONS
Visit Us on the Web! www.smokealarms.com MODEL SS-901 EARLY WARNING PHOTOELECTRIC SMOKE & FIRE ALARM READ ALL INSTRUCTIONS The smoke alarm has a recommended service life of at least 10 years under normal
More informationFIRE PREVENTION AND SAFETY IN THE HOME. Provided to You by Lawrence Laviolette CD Fire Safety Officer
FIRE PREVENTION AND SAFETY IN THE HOME Provided to You by Lawrence Laviolette CD Fire Safety Officer 1 COMMON SENSE!! Prevents Fires 2 FIRE BASICS HEAT FUEL OXYGEN REMOVE THE FUEL, CUT OFF THE OXYGEN SUPPLY,
More informationEN ES-D5B Wireless Smoke Detector. Instrukcja pobrana ze sklepu
EN 14604 ES-D5B Wireless Smoke Detector Instrukcja pobrana ze sklepu www.ekocentrum24.pl EN Contents Introduction............... 3 Box Content............... 3 Specifications. 4 Installation. 4 Connect
More informationUSER S MANUAL. BATTERY POWERED PHOTOELECTRIC SMOKE ALARM WITH SILENCE FEATURE Models 710E, 710LE and SA710CE
USER S MANUAL BATTERY POWERED PHOTOELECTRIC SMOKE ALARM WITH SILENCE FEATURE Models 710E, 710LE and SA710CE IMPORTANT! PLEASE READ CAREFULLY AND SAVE. This user s manual contains important information
More informationFire Safety & Evacuation Procedures
Fire Safety & Evacuation Procedures These fire procedures have where possible been prepared in accordance with Australian Standard 3745 2002 Emergency Control Organisation and Procedures for Buildings,
More informationthe Smart Toast Instruction Book - BTA825/BTA830/BTA845
the Smart Toast Instruction Book - BTA825/BTA830/BTA845 Contents 2 Breville Recommends Safety First 7 Components 8 Functions 13 Care & Cleaning BREVILLE RECOMMENDS SAFETY FIRST At Breville we are very
More informationTHE TOWNSHIP OF CRANBURY
THE TOWNSHIP OF CRANBURY FIRE SAFETY BUREAU 23-A North Main Street Cranbury, NJ 08512 PHONE 609-664-3137 FAX 609-395-8861 Dear Cranbury Resident/Real Estate Agent: There have been some changes to the Certificate
More informationPhotoelectric Smoke Alarm User s Guide
SINGLE STATION SMOKE ALARM Photoelectric Smoke Alarm User s Guide Model: p9050ca 9V Battery Operated ATTENTION: Please take a few minutes to thoroughly read this user s guide which should be saved for
More informationThe Specialist s Choice
The Specialist s Choice FIRE EXTINGUISHERS Water Water Plus Foam CO2 Powder Wet Chemical The Specialist s Choice Why choose Commander? With one of the widest ranges available on the market today, Commander
More informationSmoke Alarms. Rev. A Copyright 2011 James D Peisker
Residential smoke alarms are underappreciated by the general public for the life-saving devices they truly are. Recent statistics show a death rate twice as high in homes without a functioning smoke alarm
More informationSMOKE & HEAT DETECTOR
SMOKE & HEAT DETECTOR MODEL: RWX34S INSTALLATION INSTRUCTIONS GENERAL DESCRIPTION RISCO Group s RWX34S Wireless Smoke and Heat Detector combines advanced technologies within a compact and streamlined design,
More informationLb. Clear SAVE $10 SAVE $10. Friendly Place. Serious Service. October is Fire Prevention Month!
Friendly Place. Serious Service. 8 49 October is Fire Prevention Month! AC/DC Smoke Alarm Wired-in smoke alarm with 9V battery back up UL listed 9V battery included 557102 49 97 6 Cu. Ft. Wheelbarrow 16"
More informationEFFECTIVE DECEMBER 28, 2010 SECTION 610 CARBON MONOXIDE ALARMS
SECTION 610 CARBON MONOXIDE ALARMS 610.1. General. Section 610 covers the application, installation, performance and maintenance of carbon monoxide alarms and carbon monoxide detectors, and their components,
More informationOwners Manual OWNERS MANUAL. Australia s original Outdoor brand. Part No. Comp830Li. SAI Global Cert. SAI AS
Owners Manual AQUACUBE LOGIC Li RECHARGEABLE CAMP SHOWER Part No. Comp830Li SAI Global Cert. SAI - 400135 AS 2658-2008 OWNERS MANUAL Australia s original Outdoor brand INTRODUCTION Important: Read these
More informationOwners Manual OWNERS MANUAL. Australia s original Outdoor brand. Part No. Comp827. SAI Global Cert. SAI AS
Owners Manual AQUACUBE RV digital water heater Part No. Comp827 WARNING OUTDOOR USE ONLY SAI Global Cert. SAI - 400097 AS 2658-2008 OWNERS MANUAL Australia s original Outdoor brand Important: Read these
More informationThe six tests conducted included three smoldering and three fast flaming type tests.
The Mayfield Village Tests On May 9, May 12 and May 13, 2014 NEOFPA conducted six full-scale, real-world smoke alarm comparison tests in the city of Mayfield Village, Ohio. Tests 5 and 6 conducted on May
More informationPk. Yard Waste Bags Therma-Fit SAVE $10. Friendly Place. Serious Service. October is Fire Prevention Month!
Friendly Place. Serious Service. 8 49 AC/DC Smoke Alarm Wired-in smoke alarm with 9V battery back up UL listed 9V battery included 557102 October is Fire Prevention Month! 49 97 6 Cu. Ft. Wheelbarrow 16"
More informationWIRELESS INTERLINK SMOKE ALARM + 10 YEAR LIFE WST-630
User Manual WIRELESS INTERLINK SMOKE ALARM + 10 YEAR LIFE WST-630 Please read me as I could save your life. Please retain this user manual for future reference Are you protected from deadly carbon monoxide?
More informationHousing Fact Sheets. Home Fire Protection
Home Fire Protection Housing Fact Sheets Introduction The National Fire Protection Association (NFPA) collects and compiles information about how and where fires occur in the United States. The most recent
More information