Size: px
Start display at page:

Download ""

Transcription

1 A Leading Manufacturer of IR thermometer & Gas detector. Monitoring Temperature and Gases. Digital Controller Smoke sensor Gas Detector Portable Infrared thermometer Multi-input indicator Fixed Infrared thermometer Wireless Indoor Air Quality Monitor Portable Gas Detector

2 COMPAY HISTORY Acquired KR (Korean Register of Shipping Certification) - Developed Infrared Rays Thermometer for FILM (FILM-7.9) - Developed Infrared Rays Thermometer for Glass (GLASS-5.2) - Developed oxygen analyzer of irconia sensor (DA-60) - Developed IR-Brazing for Brazing(fire penetration) - Developed Gas Detector that can sense F3, SF Developed View type Infrared thermometer (IR-VIEW) - Developed on-contact subminiature Fixed Infrared thermometer (IR-compact,IR-22). - Developed on contact Temperature + Smoke Detector(TS-60). - Acquired CE-Mark for IR-Compact Developed Two color Pyrometer(SS-0, 2IGA-0). - Participated in exhibition Sensor + Test 2013' in uremberg, Germany Developed wireless indoor air quality monitor 'IAQ-700' - Registered patent for Infrared thermometer in Korea - Acquired CE-Mark for SD-50 - Participated in exhibition 'Industrial Automation Show' in Hannover, Germany and Shanghai, China Selected as promising small and medium enterprises by Incheon city Developed InGaAs Pyrometer - Developed Silicon Pyrometer Developed TCD Hydrogen Detector first in Korea Selected as Venture company - Acquired CE-Mark for DA Developed Thermopile Infrared thermometer first in Korea Developed DIR Detector first in Korea Acquired ISO9001,ISO Registered utility model patent and design for smoke senor GasDA Co.,Ltd is a professional and leading manufacturer of Fixed Infrared thermometers, Gas detectors and smoke detectors for factory automation and process control in industry. GasDA is focusing on developing and distributing more convenient and stable gas detectors and infrared thermometers. Based on the technologies and expertise accumulated Since 2003, we have positioned as Korea's only infrared thermometer manufacturer, and we are planning to expand into not only the domestic market but overseas markets. We develop and manufacture efficient and reliable products based on state-of-the-art technologies, and we do our best to be the world's leading company in the gas detector and Infrared thermometer field. GasDA promise customer's safety and product quality in accordance with the quality assurance K mark and ISO9001 quality system to maximize the customer's use value. C.E.O GasDna Co.,Ltd 고성운

3 co.,ltd A Leading Manufacturer of IR thermometer & Gas detector. Monitoring Temperature and Gases. COTETS Fixed Infrared Thermometer IR-80 Brazing-3.9 Glass-5.2 Film-7.9 IR-View 2IGA-0 SS-0 IR-80-H 4-IRman 6-IRman IR-22 IR-Compact IR-40 IR-20 Indicator DI-20 Infrared Thermometer Accessories Portable Infrared Thermometer PIR550 PIR1500 PIR2400 Smart Gas Detector DA-500 Series DA-0 Series Oxygen analyzer DA DA-750-O2 14 SMART Gas Detector DA-800 Series 15 DA-750 Series 15 DA-50 Series 16 DA-90- Series 16 Digital Controller of Gas Detector GMS GMS GMS Indicator DA Portable Gas Detector Clip 19 Gasman 19 GasPro 19 Tetra3 19 Target gas list 20 Smoke Sensor SD Temperature & Smoke Sensor TS TS Wireless Indoor Air Quality Monitor IAQ Certificate Status 23 Gas Detector Digital Controller Portable Gas Detector Smoke sensor Fixed Infrared thermometer Portable Infrared thermometer Multi-input indicator Wireless Indoor Air Quality Monitor

4 Fixed Infrared Thermometer *OEM Service is available, Please contact us for further information. IR-80 Subminiature on-contact infrared thermometer Brazing-3.9 Brazing,welding * Optical Field of View (0:1) 5. 광학챠트 (DS 80:1) * Optical Field of View (60:1) DISTACE: SESOR TO OBJECT (I) SPOT DIA.* (MM) SPOT DIA.* (I) D:S=80: DISTACE: SESOR TO OBJECT (MM) *FOCUS POIT D:S = 80:1 FAR FIELD D:S = 80:1 Product Specification 6. 방사율조정및레이저조정방법 Range Resolution Emissivity 레이저스위치 [ 방사율조정 ] 하우징뒷면의딥스위치를조절하여방사율조절할수있다. Sensor [ 레이저조준 ] 대상체의위치를조준하기위해서레이저스위치를동작시킨다. 스위치를누를때마다 O/OFF 된다. 레이저는 5분후자동으로꺼짐 Field of View (D:S) Wavelength Range Code umber 방사율조정 150 ~700 IR ~0.99 Within 50msec ±1%/F.S or 1 InGaAs, Silicon 0:1 500 ~ ~1.1 μm, 1~1.6 μm, 2.0 μm DC 20~24V (Max 50mA) Aluminum 3m, other IR Temperature range ~ ~ ~2200 (Silicon sensor) 4 150~700 (Extend InGaAs 2.6um) 5 75 ~400 output M DC 0~20mA V Voltage output DC 1~5V length 1 3M * Application : Aluminum, Chrome, Copper, Metal, Magnesium, Oxidenickel, Platinum, Gold, Silver, Oxided-Titanium, inc, Tin, Steel, Oxided- Steel, Oxided-Brass Product Specification Range Resolution Emissivity Field of View(D:S) Wavelength Range Code umber Brazing ~ ~1.00 Within msec ±1%/F.S or 1 60:1 3.9 μm DC 20~24V (Max 200mA) SUS 3M, Brazing ~ ~1600 Length 1 3M Temperature range * Application : Brazing, Rivet forge, Ladle, Glass, Kiln, incinerator, etc,. 4

5 Fixed Infrared Thermometer *OEM Service is available, Please contact us for further information. Glass-5.2 Glass Film-7.9 Film, Plastic Brazing-3.9 * Optical Field of View (60:1) MODE UP DOW ETER * Optical Field of View (60:1) Product Specification Product Specification Glass-5.2 Range 250~1300 Resolution 1 Emissivity 0.01~1.00 Within 0.01Msec ±1%/F.S or 1 Field of View(D:S) 60:1 Wavelength Range 5.2μm DC 20~30V (Max 200mA) AL 3M, Film-7.9 Brazing-3.9 Range 0~500 Resolution 1 Emissivity MODE UP 0.01~1.00 DOW ETER 0.01초이내 ±1%/F.S or 1 Field of View(D:S) 60:1 Wavelength Range 7.9μm DC 20~30V (Max 200mA) AL 3M, Code umber Glass Code umber Film Temperature Range 1 250~ ~1600 Length 1 3M Temperature Range 1 0~ ~700 length 1 3M * Application : A sort of Glass * Application : Plastic, Film, etc,. 5

6 Fixed Infrared Thermometer *OEM Service is available, Please contact us for further information. IR-View series View Type Pyrometer 2IGA-0 2-Color pyrometer * Optical Field of View (0:1) LED Display 렌즈 View type enables users to focus on a measure object which cannot be pointed by laser because of strong light emission. Users can see through the measure object through the lens and focus more accurately. SPOT SIE [mm] MEASURIG DISTACE A[mm] Product Specification IR-View 1 color 2 color Range 800 ~2400 Resolution 1 Emissivity 0.1~0.99 Within 0.001sec ±1%/F.S or ~1.25 Detection sensor Si or InGaAs or 2 Color-Si/Si Field of view(d:s) 200:1 Wave length Range umber 1 Color 1.0 μm, 1.1 μm DC 12~24V (Max 200mA) Aluminum 3m, other Temperature Range IR-View-1 0~600 IR-View-4 400~1500 IR-View-8 800~2400 IR-View- 00~ Color IR-VIEW-2IG-3 300~700 IR-VIEW-SS-8 800~2400 IR-VIEW-SS- 00~3000 * Application : Aluminium, Chrome, Copper, Magnesium, ickel Oxide, Platinum, Gold, Silver, Titanium Oxide, inc, Tin, Stee, Etc,. Product Specification 2IGA-0 1 color 2 color Range 400 ~1200 Resolution 1 Emissivity 0.1~ ~1.25 Within 0.01sec ±1%/F.S or 1 Detection sensor Code umber 2 Color-InGaAs/InGaAs Field of view(d:s) 0:1 Wave length Range 1.0~1.5μm DC 12~24V (Max 200mA) SUS 3m, other 2IGA Temperature range ~ ~1200 M DC 0~20mA V DC 1~5V length 1 3M * Application : Aluminium, Chrome, Copper, Magnesium, ickel Oxide, Platinum, Gold, Silver, Titanium Oxide, inc, Tin, Stee, Etc. 6

7 Fixed Infrared Thermometer *OEM Service is available, Please contact us for further information. SS-0 2-Color pyrometer IR-80-H High temperature on-contact Infrared Thermometer * Optical Field of View (0:1) 5. 광학챠트 (DS 0:1) * Optical Field of View (80:1) 5. 광학챠트 (DS 80:1) DISTACE: SESOR TO OBJECT (I) SPOT SIE [mm] MEASURIG DISTACE A[mm] SPOT DIA.* (MM) SPOT DIA.* (I) D:S=80: DISTACE: SESOR TO OBJECT (MM) 6. 레이저조정방법 *FOCUS POIT D:S = 80:1 FAR FIELD D:S = 80:1 Product Specification [ ET 스위치 ] SS0 1 color 2 color Range 800 ~2400 Resolution 1 Emissivity 대상체의위치를조준하기위해서레이저스위치를동작시킨다. ET 스위치를누를때마다레이저 O/OFF 된다. 7. 제품구성및명칭 0.1~0.99 Within 0.01sec ±1%/F.S or 1 Detection sensor 2 Color-Si/Si Field of view(d:s) 0:1 Wave length Range 0.8~1.1 μm 0.75~1.25 DC 12~24V (Max 200mA) SUS 3m, other Product Specification 6. 방사율조정및레이저조정방법 IR-80-H Range 150~ ~1700 Resolution 0.1 Emissivity 0.1~0.99 Within 0.1sec ±1%/F.S or 1 Field of view(d:s) 80:1 Wave length Range 1~1.6μm, 2.6μm, 0.85~1.1μm DC 16V~24V (Max 50mA) Aluninum 3m, other 레이저스위치 [ 방사율조정 ] 하우징뒷면의딥스위치를조절하여방사율조절할수있다. [ 레이저조준 ] 대상체의위치를조준하기위해서레이저스위치를동작시킨다. 스위치를누를때마다 O/OFF 된다. 레이저는 5분후자동으로꺼짐 방사율조정 Code umber SS Code umber IR-80-H- - - Temperature range ~ ~2400 M DC 0~20mA V Voltage DC 1~5V length 1 3M * Application : Aluminium, Chrome, Copper, Magnesium, ickel Oxide, Platinum, Gold, Silver, Titanium Oxide, inc, Tin, Stee, Etc,. Temperature range ~ ~ ~2200 M DC 0~20mA V Voltage Ourput DC 1~5V length 1 3M * Application : Aluminium, Chrome, Copper, Magnesium, ickel Oxide, Platinum, Gold, Silver, Titanium Oxide, inc, Tin, Stee, Etc,. 7

8 4-IRMA MODE UP DOW ETER 6-IRMA MODE UP DOW ETER Fixed Infrared Thermometer *OEM Service is available, Please contact us for further information. 4-IRman on-contact Infrared Thermometer 6-IRman on-contact Infrared Thermometer 6. 결선및단자설명 o. 인쇄명용도 1 24V 전원 24VDC(+) 2 0V 전원 0V(-) 3 Out + 4 Out mA아날로그출력 (+) 5 TX RS485 TX+ 4-20mA아날로그출력 (-) 6 RX RS485 TX- 7 ALARM1 RELAY COTACT 8 9 AL1[O/COM] ALARM2 RELAY COTACT * Optical Field of View (:1) 7. 광학챠트 (DS :1) AL2[O/COM] * Optical Field of View (:1) DISTACE: SESOR TO OBJECT (I) SPOT DIA.* (MM) SPOT DIA.* (I) DISTACE: SESOR TO OBJECT (I) D:S=: DISTACE: SESOR TO OBJECT (MM) *FOCUS POIT D:S = :1 FAR FIELD D:S = :1 SPOT DIA.* (MM) SPOT DIA.* (I) IRMA D:S=:1 MODE UP DOW ETER DISTACE: SESOR TO OBJECT (MM) *FOCUS POIT D:S = :1 FAR FIELD D:S = :1 4-IRMA MODE Product Specification Product Specification 4-IRman Range -60~400 Resolution 0.1 Emissivity 0.~1.00 Within 0msec ±1%/F.S or 1 Field of view(d:s) :1 Wave length Range 8~14μm DC 20~24V (Max 200mA) SUS 3m, other 6-IRman Range -20 ~600 Resolution 0.1 Emissivity 0.~0.99 Within 0msec ±1%/F.S or 1 Detection sensor Thermopile Field of view(d:s) :1 Wave length Range 8~14μm DC 20~24V (Max 200mA) SUS 3m, other Code umber 4-IRman- - - Temperature range 1-20~ ~400 length 1 3M Code umber 6-IRman- - - Temperature range 1-20~ ~600 M DC 0-20mA length 1 3M * Application : Plastic, Lumber, Rubber, Glass, Paper, Asphalt, Ceramics, Food, Etc,. * Application : Plastic, Lumber, Rubber, Glass, Paper, Asphalt, Ceramics, Food, Etc,. 8

9 Fixed Infrared Thermometer *OEM Service is available, Please contact us for further information. IR-22 Subminiature on-contact Infrared Thermometer IR-Compact Subminiature on-contact Infrared Thermometer * Optical Field of View (:1) * Optical Field of View (8:1) DISTACE: SESOR TO OBJECT (I) DISTACE: SESOR TO OBJECT (I) ETER SPOT DIA.* (MM) SPOT DIA.* (I) D:S=: DISTACE: SESOR TO OBJECT (MM) SPOT DIA.* (MM) SPOT DIA.* (I) D:S=8: *FOCUS POIT D:S = :1 FAR FIELD D:S = :1 DISTACE: SESOR TO OBJECT (MM) *FOCUS POIT D:S = 8:1 FAR FIELD D:S = 8:1 Product Specification Code umber IR-22 Range -60~380 Resolution 0.1 Emissivity 0.95 fixed (Changeable when using PC software program) Within 0msec ±1%/F.S or 1 Ambient temperature -20~70 Field of View (D:S) :1 Wavelength Range Input power 8~14 μm DC 12~24V (Max 50mA) SUS 3m, other IR Temperature range 1 0~ ~ ~350 M DC 0~20mA V Voltage output DC 1~5V length 1 1M *Application : Plastic, Lumber, Rubber, Glass, Paper, Asphalt Concrete, Oxidized Steel, Asphalt, Ceramics, Food, Etc,. Product Specification IR-Compact Range -60~380 Resolution 0.1 Emissivity 0.~0.99 Within 0msec ±1%/F.S or 1 Ambient temperature -30~85 Field of View (D:S) 8:1 Wavelength Range 8~14μm Wavelength Range DC 12~24V (Max 200mA) SUS Waterproof IP65, EMA 4 3m, other Code umber IR-Compact- - - D:S 1 8:1 2 12:1 (Option) Temperature Range 1 0~ ~350 Code D length 1 1M *Application : Plastic, Lumber, Rubber, Glass, Paper, Asphalt Concrete, Oxidized Steel, Asphalt, Ceramics, Food, Etc,. 9

10 Fixed Infrared Thermometer *OEM Service is available, Please contact us for further information. IR-40 on-contact Infrared Thermometer IR-20 on-contact Infrared Thermometer View type Pyromete * Optical Field of View (40:1) * Optical Field of View (:1) DISTACE: SESOR TO OBJECT (I) DISTACE: SESOR TO OBJECT (I) SPOT DIA.* (MM) SPOT DIA.* (I) D:S=40: DISTACE: SESOR TO OBJECT (MM) *FOCUS POIT D:S = 40:1 FAR FIELD D:S = 40:1 SPOT DIA.* (MM) SPOT DIA.* (I) D:S=: DISTACE: SESOR TO OBJECT (MM) *FOCUS POIT D:S = :1 FAR FIELD D:S = :1 Product Specification IR-40 Range 0 ~1,000 Resolution 0.1 Emissivity 0.1~0.99 Within 0msec ±1%/F.S or 1 Detection Sensor Thermopile Field of View (D:S) 40:1 Wavelength Range 8~14μm DC 20~24V (Max 50mA) Aluminum 3m, other Product Specification IR-20 Range 0 ~400 Resolution 0.1 Emissivity 0.95(Fixed) Within 0msec ±1%/F.S or 1 Waterproof IP65, EMA 4 Field of View (D:S) :1 Wavelength Range 8~14μm DC 20~24V (Max 50mA) Aluminum 3m, other Code umber IR Code umber IR Temperature range 1 0 ~ ~ ~00 M DC 0~20mA V Voltage output DC 1~5V length 1 3M * Application : Plastic, Lumber, Rubber, Glass, Paper, Asphalt Concrete, Oxidized Steel, Asphalt, Ceramics, Food, Etc,. Temperature range 1 0 ~ ~400 V Voltage outputdc 1~5V length 1 3M * Application : Plastic, Lumber, Rubber, Glass, Paper, Asphalt Concrete, Oxidized Steel, Asphalt, Ceramics, Food, Etc,. 8

11 Indicator / Infrared Thermometer Accessories DI-20 Multi Input Indicator -compact type DI-20 DI-20 Input Type (User-Selectable Multiple Input) TC (B, R, S, K, E, J, T, ), RTD (DI PT1, DI PT(0.1), JIS PT) DC (mv, V, ma) Communication Specification (Option) Kind : RS232, RS422, RS485, ID (Address) setup : 1 ~ 127 Signaling speed : 4800 bps ~ bps ±0.2% / Signal : ±0.25% (Full scale) Signal (Option) Electrical insulation Current : DC4 ~ 20 ma / 600 Ω Dimensions and Display Cycle Input Resistance 0 ms (mv, Volt, ma type), 200 ms (TC, TRD type) Volt type is 400 kω, ma type is 250 Ω, 1 MΩ is for other type Use Environment Power Consumption Storage Temperature/Humidity : -20 ~70 / 5%~95% Operating Temperature/Humidity : -5 ~60 / %~90% 3.5 W (Max.) Signal Source Resistance PT0 Ω, 30 Ω/Line, types 300 Ω / Line AC 85V~264V MRR / CMRR More than 50 db / More than 140 db Insulation resistance FG input, FG power, power input, More than 0 MΩ (500 VDC) Alarm (Option) Channels : 2 or 4 alarms, Contact point : 1a (ormal, Open) Contact capacity : AC 250 V / 5 A, DC 30 V / 5 A Built-in Sensor Power DC 24 V / 30 ma / less than ±0.5 % Weight About 350g Installation Method Panel-mounting type Size (mm) 96 (W) x 48 (H) x 0 (D) mm Infrared Thermometer Accessories Options Airpurge Water-cooling jacket Laser pointer Bracket RS485 to RS232 Converter 11

12 Portable Infrared Thermometer *OEM Service is available, Please contact us for further information. PIR-550 Portable Infrared Thermometer PIR550 Range -60 ~550 Wavelength Range 8~14 μm Operating Temperature 0~50 2 or ±2% of measured value Emissivity 0.1~1.0 within 1 Sec. Field of View (D:S) 12:1 Battery life Dimensions Weight min 14 hours continuous use 143.9*116.73*42.78mm 180g(including battery) PIR-1500 Portable Infrared Thermometer PIR1500 Range -35 ~1500 Wavelength Range 8~14 μm Operating Temperature 0~50 2 or ±2% of measured value Emissivity 0.1~1.0 within 1 Sec. Field of View (D:S) 75:1 Memory Battery life Dimensions Weight Detailed 24 Memories with Temperature & Emissivity min 14 hours continuous use (without Laser and Back Light) *179.19*58.40mm 355g(including battery) PIR-2400 Portable Infrared Thermometer PIR-2400 Range -200 ~2400 Wavelength Range 1~2 μm Operating Temperature 0~50 2 or ±2% of measured value Emissivity 0.1~1.0 within 1 Sec. Field of View (D:S) 0:1 Memory Battery life Dimensions Weight Detailed 24 Memories with Temperature & Emissivity min 14 hours continuous use (without Laser and Back Light) 233.8*207.5*60.6mm 550g(including battery) 12

13 MO. 24v o r g ww. w DA-500 Series Indicator type, Explosion proof DA-0 Series on-indicator type, Explosion proof 2. 사양 1) Type: Shield 2) 전송거리별케이블사양 전송거리 0 ~ 500 M 501 ~ 1,500 M 1,500 M 이상 [ Dimension ] 전선규격 0.75sq 1.25sq 2.0sq 1. 평면도 2. 측면도 H2 0 %LEL 00 DA DA D A S m S E X e n E 0 p a II C T 5 M / G - H 2 D E. S o E r X e n E 0 p a g II C ww. T 5 w M / G - H 2 D SMART Gas Detector 2. 사양 1) Type: Shield 2) 전송거리별케이블사양 전송거리 0 ~ 500 M 501 ~ 1,500 M 1,500 M 이상 전선규격 0.75sq 1.25sq 2.0sq [ Dimension ] 1. 평면도 00-1 DA DA D X D 01 G A S DEL MO m 24v a.c ow sd R O CT ET E -1 DEL 01 X D G ET a.c ow sd R O CT 2. 측면도 9 DA-500 DA-0 Detection Principle Catalytic combustion, on-dispersive infrared (DIR), TCD, Electro-chemical Detection Principle Catalytic combustion, TCD, Electro-chemical Detection Method Target Gas Detection Range Diffusion type Combustible gas, Toxic gas 0~0% LEL, 0~,000 PPM, 0~0% VOL Within 20sec, 90%/full scale Detection Method Target Gas Detection Range 9 Diffusion type Combustible gas, Toxic gas 0~0% LEL, 0~,000 PPM, 0~0% VOL Display Checking Function Select ion Function External ±2%/full scale Back Light LCD(2 Line - 8 Characters) Sensor fault indication on LCD (SE -err), 2 ma Calibration concentration, Detection range setting DC 20 ~ 30V 4mA~20mA / Full scale - 2.5Km Transmission Checking Function External Within 20sec, 90%/full scale ±2%/full scale Sensor fault indication on FD (S -err), 2 ma DC 20 ~ 30V 4mA~20mA / Full scale - 2.5Km Transmission Operating Temperature/ Humidity -30 ~60, 5~95% RH (on-condensing) Operating Temperature/ Humidity -30 ~60, 5~95% RH (on-condensing) Signal CVVS & CVVSB 1.25sq x 3 Wire - Shield Type Signal CVVS & CVVSB 1.25sq x 3 Wire - Shield Type Conduit 1/2" or 3/4" PF, PT Conduit 1/2" or 3/4" PF, PT Installation Method Explosion-Proof Approval Relay contacts Wall or Pipe Station Cast Aluminum Alloy Ex d IIC T5 - KGS 2 step-relay Contact (High/Low), RS-485 Installation Method Explosion-Proof Approval Wall or Pipe Station Cast Aluminum Alloy Ex d IIC T5 - KGS 13

14 RESET UP TEST POWER FAULT AL1 AL2 MODE DOW ET UP MOTOR DOWM SMART Oxygen Analyzer DA-60 Indicator type, Smart oxygen analyzer DA-750-O2 Suction Type Smart oxygen analyzer H3 0.0 F L O W PPM DA-60 DA-750-O2 Detection Principle zirconia O2 sensor Detection Principle Electrochemical, zirconia O2 sensor Detection Method Diffusion type Detection Method Suction type Gas Suction 6øtube Target gas O2 Detection Range 1~00ppm,0~000ppm,0~25% VOL Detection Range 0~00ppm, 1ppm~25% VOL (T90) Within sec Within sec Warmming up time Approx. 3 min ±3%/full scale ±1%/full scale Signal CVVS & CVVSB 1.25sq X 3Wire - Shield type Display 4 Digit Display DC 20 ~ 30V Selection Function Calibration concentration, Detection-range setting DC 20 ~ 30V External Operating Temperature / Humidity 4mA~20mA / Full scale - 2.5Km Transmission -20 ~50, 5~95% RH (on-condensing) External Operating Temperature / Humidity 4mA~20mA / Full scale - 2.5Km Transmission -20 ~50, 5~95% RH (on-condensing) Selection Function Installation Method Calibration concentration, Detection-range setting Wall or Pipe Station Installation Method Wall or Pipe Station 2 Step-Relay Contact (ALARM-1/ALARM-2) Cast Aluminum Alloy Relay contacts RS

15 RESET UP TEST POWER FAULT AL1 AL2 MODE DOW ET UP MOTOR DOWM SMART Gas Detector DA-800 Series Suction type Explosion proof DA-750 Series Suction type Smart Gas detector 0.0 F L O H3 PPM W DA-800 DA-750 Detection Principle Catalytic, DIR, TCD, Electro-chemical,PID Detection Principle Catalytic, DIR, Electro-chemical,PID Detection Method Suction type Detection Method Suction type Target Gas Combustible gas, Toxic gas, O2, VOC Target Gas Combustible gas, Toxic gas, O2, VOC Detection Range Induced Vacuum Flow Checking Function Select ion Function External Operating Temperature /Humidity Signal Conduit Installation Method Explosion-Proof Approval 0~0% LEL, 0~0% VOL, 0~,000 PPM Within 20sec, 90%/full scale ±2%/full scale 0.2 l/min ~ 2.5 l/min Auto - Calibration With Magnetic Switch Calibration concentration, Detection-range setting DC 20 ~ 30V 4mA~20mA / Full scale - 2.5Km Transmission -20 ~60, 5%~95% RH (on-condensing) CVVS & CVVSB 1.25 sq x 3Wire shielded type 1/2 or 3/4 PF, PT Wall Mounting Type Cast Aluminum Alloy Ex d IIB+H2 T6- Korea Gas Safety Corporation (KGS) Induced Vacuum Flow External DC 20V~30V (24 V DC ormal) / 250mA (Max.) 0.2 l/min ~ 2.5 l/min ±2%/full scale 4mA~20mA DC /F.S, RS-485 Gas Leak Data Storage Gas leak records: 4,000 Display Operating Display Alarm Value Setting Alarm Delay Time Relay s Operating Temperature /Humidity Installation Method Signal Graphic LCD (128 dots*64 dots)korean/english PPM, % LEL, %VOL (Adjustable by user programming) 4 LEDs (Power, 2 Alarms, 1 Trouble) AL1, AL2 2 Stage (Adjustable by user programming by user) 0 ~99sec (Adjustable by user programming by user) 250V 0.6A / 3 SPDT Relay-Contact (2 Alarm, 1 Trouble) -20 ~ 50, 5% ~ 95% RH (on-condensing) Wall Mounting Type CVVS & CVVSB 1.25 sq x 3 wire - shielded type Relay contacts 2 Step Relay-Contact (High/Low), RS-485 Gas Flow Distance Less than 0m Suction Line Conduit Pipe 1/4 Tube Gas Inlet Tube 6Ø Tube 15

16 PW Alarm AL-1 AL-2 Gas Detector DA-90- RESET MODE UP DOW ETER SMART Gas Detector DA-50 Series Indicator type Smart Gas Detector DA-90- Series Waterproof type Smart Gas Detector Product Specification Product Specification DA-50 DA-90- Detection Principle Detection Method Target Gas Catalytic, Electrochemical, on-dispersiveinfrared (DIR), Photo-ionization (PID) Diffusion type Combustible gas, Toxic gas ±2%/full scale DC 20V~30V (24V DC ormal) / 0mA (Max.) Detection Principle Detection Principle Response time Target Gas Selectable function Electrochemical Diffusion type Within sec 90%/Full Scale CO (0~00ppm) ±2%/Full Scale Calibration density. Detection range setting External Relay s 4mA~20mA, 2Step Relay (AL1, AL2) RS V 0.6 A / 2-SPST Relay-Contact (2 Alarms) Input power power AC 220V/60Hz 4~20mA/Full Scale 2.5Km Transmission Low alarm AL1 LED(RED) Display Operating Display Signal Operating Temperature / Humidity Installation Method LCD(8Characters*2Line) With Back-light %,PPM,PPb 4 LEDs (Power, 2 Alarms, 2-RS485 TX, RX) Cvvs &Cvvsb 1.25 sq *3Wire shielded type -20 ~ 50, 5% ~ 90% RH (on-condensing) Wall Mounting Type Alarm Alarm method Operation temperature / Humidity Alarm Off High alarm AL2 LED(RED) Light bar B LED(RED) Sight Light bar Hearing Buzzer (90 db /1m) -20 ~60, 5~95% RH (on-condensing) Manual and automatic release Housing Sensor calibration Polycarbonate Calibration with switch Alarm output 2 step (AL1/AL2) alarm relay contact, RS-485 (option) User programmable Calibration density, detection range Installation Method Wall Mounting Type 16

17 Digital Controller of Gas Detector GMS-00 Single- Channel Digital controller of Gas detector GMS Channel Digital controller of Gas detector Product Specification GMS-00 Product Specification GMS-1500 Structure Single type / 1 Circuit Structure Multiple-type (4 Connection detectors)/ 4 Circuits Input Signal AC 230V / 60Hz 4~20 ma DC / Full scale Power DC 24V(250 ma ) Signal Signal Resolution Display Alarm Display Alarm Type Alarm Density Alarm Delay Time Alarm Off Alarm 4~20 ma DC / Full scale A/D Converter - ±20000 D/A Converter - 12bit %LEL (Combustible), % (Oxygen), PPM (Toxic) Low alarm AL1 LED (Red) High alarm AL2 LED (Red) Fault alarm Fault LED (Yellow) Visual : LED flickering Auditory : Buzzer sound (More than 80 db ) AL1 / AL2 2 Level alarm density (Adjustable by user programming by user) 0 sec ~ 99 sec (Adjustable by user programming by user) Manual, Automatic return 2 단 (AL1 / AL2) Relay-Contact Operating Temperature -20 ~ 50 Operating Humidity Installation Method 5% ~ 95% RH (on-condensing) Poly Carbonate (P.C) Wall Mounting Input Signal AC 220 V / 60 Hz, AC 1 V / 60 Hz (Option) 4 Channels (4~20 ma / FS) Power DC 24V (250 ma ) Signal Display Alarm Display Alarm Type Alarm Value Setting Alarm Delay Time Alarm Off Alarm 4 Channels (4~20 ma / FS) LCD Display PPM, % LEL, %, PPB (Adjustable by user programming by user) Low alarm AL1 LED (Red) High alarm AL2 LED (Red) Fault alarm Fault LED (Yellow) Visual : LED Flickering Auditory : Buzzer sound (More than 80 db ) AL1/AL2 2 Level alarm (Adjustable by user programming by user) 0 ~ 99 sec (Adjustable by user programming by user) Manual, Automatic return 250 V 5 A / 11-SPST Relay-Contact ( Alarms, 1 Fault) Operating Temperature - ~ 50 Operating Humidity Installation Method 5 ~ 95%RH (on-condensing) Poly Carbonate (P.C) Wall Mounting Option Light Bar Option Light Bar 17

18 Digital Controller of Gas Detector / Indicator GMS-2000 Multi-Channel Digital controller of Gas detector DA-90 Large Size Indicator [ 외형치수 ] GAS ALARM COTROL SYSTEM ( 주 ) 가스디엔에이 Product Specification Control Structure Extension Structure Input Signal Alarm unit : Receiving unit = 1:1 ~ 64 GMS-2000 Receiving unit : detector = 1:1 Slide Card Type AC 230V / 60Hz Power DC 24V (250 ma ) Input Signal Power & Alarm Unit 4~20 ma DC / F.S Receiving Unit 9 page Product Specification DA-90 Structure Single type / 1 Circuit Display Large size FD 5 DIGIT(2.3 Inch) AC 230V/60Hz Input signal 4-20mA DC/F.S Power DC 24V(750mA ) Signal 4 ~ 20 ma DC / F.S, RS-485(Option) Signal 4-20 ma DC/F.S Display Power Display Alarm Display Alarm Type Alarm Density % LEL (Combustible), % (Oxygen), PPM (Toxic) Alarm LED (Red) Alarm LED flickering Buzzer sound (More than 90 db ) Power LED (Green) Low alarm AL1 LED (Red) High alarm AL2 LED (Red) Fault alarm - Fault LED (Yellow) Visual : Applicable alarm LED Flickering High / Low - 2Level alarm density (Adjustable by user programming by user) Alarm Display Alarm Type Alarm Value Setting Low alarm AL1 LED (Red) High alarm AL2 LED (Red) Fault alarm - Fault LED (Yellow) Visual : LED Flickering Auditory : Buzzer sound (More than 80 db ) AL1/AL2 2 Level alarm (Adjustable by user programming by user) Alarm Delay Time 0 ~ 99 초 (Adjustable by user programming by user) Alarm Delay Time 0 sec ~ 99 sec (Adjustable by user programming by user) Alarm Off Manual, Automatic return Alarm Off Manual, Automatic return Alarm SPDT Relay output for High / Low 2Level alarm SPDT Relay output for Fault alarm Alarm 2step(AL-1/AL-2) Alarm RELAY COTACT, RS-485(Option) Operating Temperature / Humidity Option -20 ~50, 5~95%RH (on-condensing) 19 (3U) Unit : Aluminum / System enclosure: Metal case RS-485 Operating Temperature /Humidity Installation Method - ~ 60, 5 ~ 95%RH (on-condensing) Wall Mounting Option Light Bar 18

19 Portable Gas Detector Clip Gas man Gas pro Tetra3 single gas monitor multi gas monitor Maintenance Free Single Gas Monitor Easy to use, event logging detector with display for H2S, CO or O2. Target Gas Detection Single Gas 19 Multi Gas Clip Gas man Gas pro Tetra3 Oxygen(O 2 ) Hydrogen sulphide (H 2 S) Cafbon monoxide (CO) Carbon dioxide IR Cell (CO 2 ) S S A wide range of hydrocarbons available (CAT LEL) IR LEL Ammonia (H 3 ) Chlorine dioxide (CLO 2 ) Chlorine (CL 2 ) Sulphur dioxide (SO 2 ) Hydrogen (H 2 ) itric oxide (O) Phosgene (COCL 2 ) Fluorine (F 2 ) Phosphine (PH 3 ) Hydrogen cyanide (HC) Hydrogen fluoride (HF) Ethylene oxide (ETO) itrogen dioxide (O 2 ) Ozone (O 3 ) VOC gases (PID) STEL / TWA alarms Optional internal pumped MED approval Event logging Data logging Single button operation Software for data management s=safe area applictions Maintenance free Intrinsically Safe Personal Single Gas Monitor Advanced features & sensor options suit it to chemical plants (exotic gases), hospitality (CO2) & steel mills (special CO sensor). on Rechargeable Five-gas Monitor with Confined Space Functionality For oil & gas, water, construction & manufacturing CSE, features up to 5 gases, internal pump option & class leading size. Top Display Personal Multigas Monitor Widely used for confined space entry & recently strengthened by new gas options for the water, hospitality & steel industries. Rechargeable

20 Combustible Gas Detection Target Gas Molecular Formula Target Gas Molecular Formula Acetaldehyde CH 3 CHO Iso-butane i-c 4 H Acetic acid CH 3 COOH Iso-propyl alcohol (CH 3 ) 2 CHOH Acetone CH 3 COOH 3 Methane CH 4 Acetylene C 2 H 2 Methyl alcohol CH 4 O Benzene C 6 H 6 Methyl bromide CH 3 Br Butane C 4 H aphthalene C H 8 Chloro benzene C 6 H 5 Cl Octane CH 3 (CH 2 ) 6 CH 3 Chloro benzene C 6 H 12 Pentane CH 3 CH 2 CH 2 CH 3 Di-Methylethar CH 3 OCH 3 Phenol C 6 H 5 OH Ethane C 2 H 6 Propane C 3 H 8 Ethanol CH 3 CH 2 OH Propylene C 3 H 6 Ethylene C 2 H 4 Propylene oxide (PO) C 3 H 6 O Ethylene glycol (EG) HOCH 2 CH 2 OH Thinners Ethylene oxide (EO) C 2 H 4 O Toluene C 7 H 8 Formic acid CH 2 O 2 Vinyl acetate (VAM) CH 2 =CHOCOCH 3 Gasoline Vinyl chloride CH 2 =CHCl Heptane CH 3 (CH 2 ) 5 CH 3 Xylene C 8 H =C 6 H 4 [CH 3 ] 2 For other gases, Please inquire with us. Target Gas Detection Target Gas Molecular Formula Range DA-750 DA-50 DA-500 DA-0 Ammonia H 3 0~0 ppm Arsine AsH 3 0~1.00 ppm Boron Trichloride BCI 3 0~15.0 ppm BF 3 0~.0 ppm Bromine Br 2 0~1.00 ppm Carbon Dioxide CO 2 0~5.00%vol Carbon Monoxide CO 0~300 ppm Chlorine CI 2 0~.0 ppm Chlorine Dioxide CLO 2 0~2.00 ppm CLF 3 0~2.00 ppm Diborane B 2 H 6 0~1.00 ppm DiboraneDichlorosilane H 2 SiCI 2 0~.0 ppm CH 2 F 2 0~0 ppm Disilane Si 2 H 2 0~.0 ppm Flourine F 2 0~.0 ppm Germane GeH 4 0~1.00 ppm C 4 F 6 0~50.0 ppm Hydrogen H 2 0~0%VOL Hydrogen(% LEL) H 2 0~0%LEL Hydrogen(ppm) H 2 0~2000 ppm Hydrogen Bromide HBr 0~.0 ppm Hydrocarbon HC 0~0%LEL Hydrogen Chloride HCI 0~.0 ppm Hydrogen Cyanide HC 0~50.0 ppm Hydrogen Fluoride HF 0~.0 ppm Hydrogen peroxide H 2 O 2 0~0 ppm Hydrogen Sulphide H 2 S 0~.0 ppm Hydrogen Sulphide(High Level) H 2 S 0~0 ppm Methane(%LEL) CH 4 0~0%LEL Methyl Fluoride CH 3 F 0~60 ppm methylene chloride CH 2 CL 2 0~5000 ppm itrogen Dioxide O 2 0~20.0 ppm itric Oxide O 0~0 ppm itrogen Trifuoride F 3 0~30.0 ppm C 5 F 8 0~40 ppm O 2 0~25%vol Ozone O 3 0~1.00 ppm Phosphine PH 3 0~1.00 ppm Phosphorous Oxychloride POCI 3 0~1.00 ppm Silane SiH 4 0~20.0 ppm Sulfur Dioxide SO 2 0~20.0 ppm SF 6 0~8000 ppm SF 4 0~.0 ppm Tetra Ethyl Ortho Sillicate TEOS 0~40 ppm WF 6 0~12.0 ppm Volatile Orgenic Compounds VOCs 0~00 ppm For other gases, Please inquire with us. 20

21 Smoke Sensor SD-50 Smoke Sensor TS-60 Temperature & Smoke Sensor Temperature detection 35 Smoke detection Product Specification SD-50 Product Specification TS-60_ on contact Infrared thermometer Detection Principle Ionizations Smoke Chamber Measuring Range Device -70 ~ 380 (Alarm value setting by DIP switch) Thermopile (on contact Infrared measurement) Detection Method Diffusion type Optical Resolution Optical Spectrum 35 8~14 μm External Within 3sec A contact (DC 30 V 1 A), B contact Response time 0.3 sec Relay Relay A (DC30V 1A) TS-60_ Smoke sensor DC 22V~26V Detection Principle Ionizations Smoke Chamber Detection Method Diffusion Operating Current 25 ma. Maximum Response time Within 3sec Relay Relay A (DC30V 1A) Acetal Input power DC 22V~26V Currency consumption 50 ma. Maximum Operating Temperature / Humidity -20 ~65 / 0~95% RH (on-condensing) Operation temperature / humidity -20 ~ 60 / 0 ~ 95% RH (on-condensing) Process Digital Process Process Digital Process * Temperature setting in factory : 50 * Smoke density : 1% 21

22 Temperature & Smoke Sensor / Wireless Indoor Air Quality Monitor TS-70 Temperature & Smoke Sensor IAQ-700 Wireless Indoor Air Quality Monitor Temperature detection 35 Smoke detection IAQ-700 Product Specification TS-70_ on contact Infrared thermometer Measuring range -70 ~ 350 Device Optical Resolution Optical Spectrum Response time Relay Detection Principle Detection Method Response time Thermopile (on contact Infrared measurement) 35 8~14 μm 0.3 sec 4-20mA TS-70_ Smoke sensor Ionizations Smoke Chamber Diffusion Within 3 sec Relay Relay A (DC30V 1A) Input power Currency consumption Operation temperature / humidity Process * Temperature setting in factory : 50 * Smoke density : 1% DC 22V~26V 50 ma. Maximum -20 ~ 60 / 0 ~ 95% RH (on-condensing) Digital Process Product Specification VOC CO2 DUST Temperature Humidity Measurement range Resolution Response time Measurement range Resolution Response time Measurement range Resolution Response time IAQ ~ 1,000 ppm 1 ppm ±3%/Full Scale Within sec (T90) 0 ~,000 ppm ppm ±5%/Full Scale Within 30 sec (T90) 0 ~ 500 μg / m3 1 μg / m3 ±3%/Full Scale Within sec (T90) Measurement range -25 ~ 60 Resolution 0.2 Response time Measurement range Response time Input power Density Display Alarm Display Alarm Resolution Response time Operation Temperature/ Humidity ±2%/Full Scale Within sec (T90) 0~0%RH 0.4% RH ±3%/Full Scale Within 15 sec (T90) igbee DC 9V ~ DC24V DOT Graphic LCD Display AL-1,AL-2 LED(RED) 2 Step RELAY COTACT - ~ 70 / 5 ~ 95%RH (on-condensing) Dimension 3*157*60 Installation Wall Mounting Type 22

23 * Business License * ISO 9001:2008 Certificate * Certificate of a Patent for Leak inspection device and methode of secondary battery * Certificate of a Patent for on-contact Infrared Thermometer * DA-50 CE Certificate * DA-0 Explosion-Proof Certificate * DA-0 KR Korean Register of Shipping Certification * DA-500 Explosion-Proof Certificate * DA-750 CE Certificate * DA-800 Explosion-Proof Certificate * IR-20 CE Certification * IR-40 EMC Certification * SD-50 CE Certificate * Certificate of Design Registration- Smoke Detector * Certificate of Utility Registration- Smoke Detector 23

24 GASDA co.,ltd B-602&603B, Bupyeong Woolim Lion s Valley, #425, Cheongcheon-Dong, Bupyeong-Gu, Incheon, Korea TEL: FAX: sales@gasdna.com

SMART Gas Detector/Transmitter(4~20mA) with built-in LCD & explosion proof - Suction Type - DA- 800

SMART Gas Detector/Transmitter(4~20mA) with built-in LCD & explosion proof - Suction Type - DA- 800 SMART Gas Detector/Transmitter(4~20mA) with built-in LCD & explosion proof - Suction Type - DA- 800 C-910C, Bupyeong Woolim Lion s Valley, #425, Cheongcheon-Dong, Bupyeong-Gu, Incheon, Korea TEL: +82-32-623-7507

More information

SS-100. Pyrometer. Temperature Range: 800~2400

SS-100. Pyrometer. Temperature Range: 800~2400 Two Color Non-Contact Pyrometer Temperature Range: 800~2400 SS-100 GasDNA Co.,Ltd C-910C, Bupyeong Woolim Lion s Valley, #425, Bupyeong-Gu, Incheon, Korea TEL: +82-32-623-7507 FAX: +82-32-623-7510 E-mail:

More information

ESD3000 ESD200 Combustible / Toxic Gas Detector

ESD3000 ESD200 Combustible / Toxic Gas Detector ESD3000 ESD200 Combustible / Toxic Gas Detector Combustible and toxic gas leakage inspection instrument in industrial application Ex-proof certificate Exd ⅡC T6 Gb/Ex d ib ⅡC T6 Gb Dust Ex-proof certificate

More information

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS FEATURES Extremely wide range of sensors Easy installation and maintenance Low cost of ownership Replacement of sensors are simple Rugged and reliable

More information

SMART Gas Detector/Transmitter(4~20mA) with built-in LCD & explosion proof DA-500

SMART Gas Detector/Transmitter(4~20mA) with built-in LCD & explosion proof DA-500 SMART Gas Detector/Transmitter(4~20mA) with built-in LCD & explosion proof DA-500 C-910C, Bupyeong Woolim Lion s Valley, #425, Cheongcheon-Dong, Bupyeong-Gu, Incheon, Korea TEL: +82-32-623-7507 FAX: +82-32-623-7510

More information

ESD500. ESD500 Combustible / Toxic Gas Detector

ESD500. ESD500 Combustible / Toxic Gas Detector ESD500 ESD500 Combustible / Toxic Gas Detector Combustible and toxic gas leakage inspection instrument in industrial application Ex-proof certificate Exd ⅡC T6 Gb/Ex d ib ⅡC T6 Gb Dust Ex-proof certificate

More information

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6 Digital Gas Transmitters with Auxiliary s & Control Specifications subject to change without notice. USA 181011 Page 1 of 5 DESCRIPTION Digital RS-485 communicating, addressable toxic and combustible gas

More information

2-Channel Smoke Detector SD - 110

2-Channel Smoke Detector SD - 110 2-Channel Smoke Detector SD - 110 GASDNA CO., LTD. Rm910C, Cdong Bupyeong Woolim Lion s Valley, #425, Cheongcheon-Dong, Bupyeong-gu, Incheon Korea TEL:+82-32-623-7507, FAX:+82-32-623-7510 Website: Http://www.gasdna.com

More information

3M Oldham OLCT 100. Description. Fixed Gas Detector

3M Oldham OLCT 100. Description. Fixed Gas Detector Fixed Gas Detector Description The OLC/OLCT range of fixed detectors has been designed for detection of combustible gases, toxic gases or oxygen. Available in explosion-proof or intrinsically safe versions,

More information

Xgard. Fixed detectors For flammable, toxic or oxygen gases

Xgard. Fixed detectors For flammable, toxic or oxygen gases Fixed detectors For flammable, toxic or oxygen gases Xgard Xgard Type 1: Xgard Type 2: Xgard Type 3: Xgard Type 4: Xgard Type 5: Xgard Type 6: Xsafe: Intrinsically safe toxic and oxygen gas detector Flameproof

More information

Sieger Apex. Flexibility that meets your requirements

Sieger Apex. Flexibility that meets your requirements Sieger Apex Flexibility that meets your requirements Sieger Apex Easy to Install Sensor can be remotely mounted up to 100m from the transmitter On board relays allow for local audible/ visual alarms Strong

More information

OLC(T) 100 FIXED GAS DETECTOR

OLC(T) 100 FIXED GAS DETECTOR Fixed Gas Detector OLC(T) FIXED GAS DETECTOR Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version CERTIFICATIONS The

More information

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots 5 Operating Modes GX-6000 Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots GX-6000 5 Operating modes Normal Leak Check Inert Bar hole Snap Log Monitor up to

More information

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots 5 Operating Modes GX-6000 Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots CONFINED SPACE ENTRY Monitor LEL, O2, CO, and H2S Internal sample pump Pull samples

More information

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility EAGLE 2 Inlet fitting Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility Internal / external hydrophobic filters Self healing polyurethane protective

More information

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases DETECTION DE GAZ FIXE OLCT Detection of Combustible, Toxic or Oxygen gases Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version Certifications Better detection. Better

More information

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ] ULTIMA XL/XT Series Gas Monitors [ Ultimate Features Extreme Design ] Cost effective fixed installation gas monitors with HART Field Communications Protocol. Single-sensor units use catalytic, electrochemical

More information

Toxic Gas Detection. Model F12. Toxic Gas Detection

Toxic Gas Detection. Model F12. Toxic Gas Detection Toxic Gas Detection Model F12 Toxic Gas Detection Smart Sensor Technology The Series F12 Gas Transmitter is an Intrinsically Safe (IS) version of our explosion-proof D12 transmitter. In its standard form,

More information

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People Fixed Gas Detector Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Certifications The Fixed Gas Detection People The OLC/OLCT CT range of fixed ddetectors

More information

Model D12. Digital Gas Transmitter

Model D12. Digital Gas Transmitter Model D12 Digital Gas Transmitter Gas detection systems come in all shapes and sizes. Some require simple 4-20 ma transmission. Some are better suited to local alarm relay functions. Some really require

More information

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS FREEDOM SERIES 5000 & 5600 MAKING INSTALLATION AND EVERYDAY OPERATION EASY The Freedom Series 5000 and 5600 are full-featured 4-20mA, loop powered transmitters

More information

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases Satellite XT Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases Satellite XT Applications: Provides gas detection for: Gas cabinets Valve manifold

More information

Monitores Personales. Personal Monitor

Monitores Personales. Personal Monitor Monitores Personales Personal Monitor Micro IV Full Featured Personal Monitor Micro IV Single-gas Detector Highly configurable smart sensor design Wide range of sensors including O 2, H 2 S, CO, NH 3,

More information

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring. Water Quality Labo- Soil/ Soil/ Sedi- Sam- & Air / Dust Toxic gases are present in a wide variety of industrial and civil installations and their detection and monitoring is crucial for the safe working

More information

SP-220. Features. Combustible handheld gas leakage detector

SP-220. Features. Combustible handheld gas leakage detector SP-220 Combustible handheld gas leakage detector The SP-220 gas leakage detector is a simple to operate unit with high sensitivity to a variety of gases. The SC version (SP-220SC) is able to detect super-toxic,

More information

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version Fixed Gas Detector Detection of explosive gases, toxic gases or oxygen Infrared XP version SIL 2 high reliability IP 66 Aluminium or Stainless Steel version Certifications Pending The Fixed Gas Detection

More information

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66. Fixed Gas Monitoring Solutions Detection of explosive gases, toxic gases and oxygen Infrared XP IR version SIL 2 high reliability IP 66 E n o r t c e l i c 3years W a r r a t n y Certifications: The Fixed

More information

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

MultiRAE Lite. Wireless Portable Multi-Gas Monitor MultiRAE Lite Wireless Portable Multi-Gas Monitor The MultiRAE Lite is an optimal one-to-six 4 -gas monitoring solution for personal protection (including confined space entry) and multi-gas leak detection

More information

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY FEATURES TXGARD & FLAMGARD PLUS Digital display with flexible output options Wide range of long life sensors Non-intrusive one-man

More information

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification 1.0 This specification details the attributes and operating characteristics of the MSA Ultima X Series sensors/transmitters.

More information

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008 iso 9001:2008 Quality Management Systems Systéme de Qualité www.sgs.com possibility of additional functions detection of critical temperature detection of flooding electrochemical sensor catalytic sensor

More information

ESD3000IR ESD3000IR. Infrared Gas Detector

ESD3000IR ESD3000IR. Infrared Gas Detector ESD3000IR ESD3000IR Infrared Gas Detector Infrared gas sensor Ex-proof certificate Exd ⅡC T6 Gb Dust Ex-proof certificate Ex td A21 IP66 T80 Site LCD display HART communication Replaceable sensor design

More information

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors Ultima X Series Gas Monitors Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection methods. HART Protocol is now

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET S p e c i f i c a t i o n WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700 D e t e c t o r C o n t r o l P a n e l Wall mounting 24V DC or 110/230vAC operation

More information

ALTAIR 5X Multigas Detector Product Specification

ALTAIR 5X Multigas Detector Product Specification ALTAIR 5X Multigas Detector Product Specification PHYSICAL CHARACTERISTICS Gas delivery Size, pumped unit without IR Size, pumped unit with IR Weight Handling Case material Environmental protection Display

More information

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display. Sheet No. 1 of 4 monitor/analyzer with alarm and Graphical Display. Sheet No. 2 of 4 It specially designed to analyze any gas of your choice, its automatic operation, accurate measurement and crystal clear

More information

GAS DETECTOR ST400EC PART.NO

GAS DETECTOR ST400EC PART.NO DATA SHEET 1(7) GAS DETECTOR ST400EC PART.NO. 004461-004467 DETECTION OF TOXIC GASES AND OXYGEN SYSTEM GS5000, GS3000, SW2020, BUCONTROL / BUTOUCH GENERAL DESCRIPTION Detection of toxic gases and Oxygen

More information

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability GasSens Modular Gas Detector... Self Checking Gas Sensors GasSens is a flexible component system providing a variety of options to meet individual gas detection and alarm requirements. From chemical and

More information

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring] ULTIMA XIR ULTIMA X 3 ULTIMA XE ULTIMA X Series [ State-of-the-Art Gas Monitoring] ULTIMA X Gas Monitors [ Providing a unique Range of Capabilities] ULTIMA X are state-of-the-art gas monitors for continuous

More information

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety GDS Corp gas monitors, controllers and sensors satisfy today s needs for safety and reliability in critical gas detection

More information

SIL 2. Ultima X Series Gas Monitors CERTIFIED

SIL 2. Ultima X Series Gas Monitors CERTIFIED Ultima X Series Gas Monitors 5 Now with SIL 2 CERTIFIED Products Versatile fixed instruments provide continuous monitoring of many hazardous gases using catalytic, electrochemical, and infrared gas detection

More information

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

Gas Detection. - Disposable - Serviceable. Single Gas Detectors Gas Detection Single Gas Detectors Introduction Portable single gas detectors are used for personal protection and have the ability to detect a single gas hazard. Typically they are small, lightweight

More information

Satellite XT. Analog or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Satellite XT. Analog or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases Satellite XT Analog or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases Satellite XT Applications: Provides gas detection for: Gas cabinets Valve manifold

More information

ALTAIR 5X Multigas Detector

ALTAIR 5X Multigas Detector ALTAIR 5X Multigas Detector With MSA XCell Sensor Technology IT S WHAT S INSIDE THAT COUNTS Now with advanced PID for VOC Detection Because every life has a purpose IT S WHAT S INSIDE THAT COUNTS WORKERS

More information

Midas. Gas monitoring system for fast and reliable detection of flammable and toxic gases used in industrial manufacturing processes

Midas. Gas monitoring system for fast and reliable detection of flammable and toxic gases used in industrial manufacturing processes Midas Gas monitoring system for fast and reliable detection of flammable and toxic gases used in industrial manufacturing processes Midas Features: Over 40 gases available with extended 2 year warranty*

More information

Industrial Grade Gas Detection Detecting The Difference

Industrial Grade Gas Detection Detecting The Difference detcon inc. Industrial Grade Gas Detection Detecting The Difference PO Box 8067 The Woodlands, TX 77387 888-367-4286 (toll free) 713-559-9200 281-292-2860 (fax) sales@detcon.com Catalog #CB-0409 www.detcon.com

More information

Microtector II G gas-detector with performance test approval. Worldwide Supplier Of Gas Detection Solutions

Microtector II G gas-detector with performance test approval. Worldwide Supplier Of Gas Detection Solutions Microtector II G460 7-gas-detector with performance test approval Performance test approved multi-gas detector (290g) Extremely loud alarm, 103 db(a) for optimum personnel protection Full featured, rugged

More information

Combustible Gas Detection and Control System

Combustible Gas Detection and Control System Combustible Gas Detection and Control System DESCRIPTION Gas monitor with built-in combustible gas sensor, wall-mounted, accepts inputs from remote devices such as other gas sensors, temperature or humidity

More information

Equipment. Model R002. Description. SF6 leak detector

Equipment. Model R002. Description. SF6 leak detector SF6 leak detector Model 3-033-R002 The remarkable sensitivity of this hand held unit allows the user to detect sulfur hexafluoride to levels equivalent to 0.1 oz/year (3 grams/year). An advanced microprocessor

More information

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases DESCRIPTION Gas measuring and monitoring controller based on stateof-the-art microtechnology with integrated sensor for continuous monitoring

More information

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector. Introduction United Safety applies the detection system as a multi-point monitoring for toxic gases, combustibles and oxygen hazards. Self-powered and solar-capable, the features unequaled versatility,

More information

Micro III (Models G203, G203S, and G213) Operation Manual

Micro III (Models G203, G203S, and G213) Operation Manual Micro III (Models G03, G03S, and G13) Operation Manual Worldwide Manufacturer of Gas Detection Solutions Table of contents Page Introduction... 3 For your safety... 3 Application and use... 3 General

More information

Two-Channel Gas Controller

Two-Channel Gas Controller Two-Channel Gas Controller Specifications subject to change without notice. USA 09 Page of DESCRIPTION Highly configurable, UL 0 performance-tested and -certified, and wall-mounted gas monitor; continuously

More information

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features. Features To measure and take control of indoor air quality Three noses in same unit Air Quality (VOC), Humidity (rh) and Temperature (T) Selectable outputs 0-10 Vdc, 4-20 ma or 0-5 Vdc via jumpers on pcb

More information

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR 70086 The information in this doucment is applicable to sensors built in September, 2008 or later (Firmware 3.0) The information and technical

More information

Model D12-IR. Digital Gas Transmitter...

Model D12-IR. Digital Gas Transmitter... Model D12-IR Digital Gas Transmitter... ATI s Series D12 gas transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact

More information

MICRO III (G202 / G202s / G212) Single Gas Detector

MICRO III (G202 / G202s / G212) Single Gas Detector Operation Manual MICRO III (G202 / G202s / G212) Single Gas Detector GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 D-44143 DORTMUND TELEPHONE +49 / (0) 2 31 / 5 64 00 0 FAX +49 / (0) 2 31 / 51 63

More information

MicroRay IR-100 NEW. Inspection MicroRay IR-100

MicroRay IR-100 NEW. Inspection MicroRay IR-100 Inspection MicroRay IR-100 MicroRay IR-100 RIDGID MicroRay features fast and easy temperature measurements from a comfortable distance. The Infra Red technology allows non-contact, point and read functionality.

More information

Multi-Channel Gas Detector Monitoring Unit GMS

Multi-Channel Gas Detector Monitoring Unit GMS Multi-Channel Gas Detector Monitoring Unit GMS - 2000 C-910C, Bupyeong Woolim Lion s Valley, #425, Cheongcheon-Dong, Bupyeong-Gu, Incheon, Korea TEL: +82-32-623-7507 FAX: +82-32-623-7510 E-mail: sales@gasdna.com

More information

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen PolyGard Single Point Controller SPC-X3-XX for Toxic Gases and Oxygen DESCRIPTION Gas measuring, monitoring and warning controller based on state-of-the-art micro-technology with integrated sensor and

More information

Gas Detection For Life

Gas Detection For Life FIXED SYSTEMS Controllers Explosion Proof Transmitters Harsh Environment Systems Digester Gas Monitor PORTABLE SOLUTIONS Smallest Confined Space Personal 6 Gas with PID, IR and Toxic Single Gas Personal,

More information

The Art of Gas Detection

The Art of Gas Detection The Art of Gas Detection Flammable & Toxic Gas Detectors Smart Alarm Controllers Fire & Gas System Engineering Technical Service & Support 1 R.C. Systems has manufactured electronic and gas detection products

More information

MDA Scientific Midas. Gas monitoring system for fast and reliable detection of flammable and toxic gases used in industrial manufacturing processes

MDA Scientific Midas. Gas monitoring system for fast and reliable detection of flammable and toxic gases used in industrial manufacturing processes MDA Scientific Midas Gas monitoring system for fast and reliable detection of flammable and toxic gases used in industrial manufacturing processes Midas Features: Over 40 gases available with extended

More information

Leak detector for refrigerant gases R22, R134a, R410A, R407C...

Leak detector for refrigerant gases R22, R134a, R410A, R407C... PCE-GA3 PCE-LD 1 PCE-GA 70 Pen-sized flammable gas detector Leak detector for refrigerant gases R22, R134a, R410A, R407C... CO2 detector with data logger and software This pen-sized flammable gas detector

More information

portable gas analyser

portable gas analyser www..com portable gas analyser The largest of s analysers equipped with electrochemical cells. It can fit even up to 7 EC cells and up to 3 sensors. GA-60 has a large (320*240), graphical LCD with backlighting.

More information

Dräger PEX 3000 Flammable Gas Detection

Dräger PEX 3000 Flammable Gas Detection Dräger PEX 3000 Flammable Gas Detection The transmitter Dräger PEX 3000 detects flammable gases and vapors in concentrations below their Lower Explosion Limit Its DD-sensor provides a very long-term stable

More information

GAS PLUS ALARM SYSTEM

GAS PLUS ALARM SYSTEM GAS PLUS -IR SERIES 4688-IR COMBUSTIBLE GAS OR CARBON DIOXIDE TRANSMITTER GAS PLUS -IR TRANSMITTER SERIES 4688-IR COMBUSTIBLE GAS OR CARBON DIOXIDE TRANSMITTER The Scott Gas Plus -IR Model 4688 IR Gas

More information

Dräger Flame 2100 Flame Detection

Dräger Flame 2100 Flame Detection Dräger Flame 2100 Flame Detection Working in areas with combustible gases, vapors, or materials requires fire/ flame detection as a life-saving necessity. The best solutions must combine state-of-the-art

More information

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device Featuring an ergonomic design and innovative infrared sensor technology, the Dräger X-am 5600 is the smallest gas detection instrument for the

More information

Polytron 2. The smart gas detector

Polytron 2. The smart gas detector Polytron 2 The smart gas detector 2-951-95 Polytron 2 Highlights One universal transmitter for all electrochemical sensors Patented Plug & Play Sensor Technology Self-diagnostics of sensor and transmitter

More information

MICRO IV. Operation Manual. Single Gas Detector

MICRO IV. Operation Manual. Single Gas Detector Operation Manual MICRO IV Single Gas Detector GfG GESELLSCHAFT FÜR GERÄTEBAU MBH KLÖNNESTRASSE 99 D-44143 DORTMUND TELEPHONE +49 / (0) 2 31 / 5 64 00 0 FAX +49 / (0) 2 31 / 51 63 13 INFO@GFG-MBH.COM WWW.GASDETECTION.BIZ

More information

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012 Confined Space Monitoring Leak Investigation 1 Functions 4 Bar Hole Sampling Line Purge Testing Actual Size GX-2012 3 Operating Modes Internal sample draw pump with 50 range Low flow alarm 3 bright visual

More information

MERIDIAN UNIVERSAL GAS DETECTOR

MERIDIAN UNIVERSAL GAS DETECTOR MERIDIAN UNIVERSAL GAS DETECTOR MERIDIAN UNIVERSAL GAS DETECTOR The term universal is frequently used in the industry to characterize gas detectors that address both toxic and combustible gases, but it

More information

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 5700 IR Detection of flammable gases and vapours Dräger Polytron 5700 IR Detection of flammable gases and vapours The Dräger Polytron 5700 IR is a cost effective explosion-proof transmitter for the detection of flammable gases in the lower explosive

More information

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres]

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres] II 2G EEx ia d ATEX 100 D MT IIC T6 99 ATEX G 001 x Series [ Versatility in Explosive Atmospheres] [ The flexible solution for all your needs] After accidents with hazardous material the will provide reliable

More information

IMR EX610. Portable Gas Detector. Operation Manual

IMR EX610. Portable Gas Detector. Operation Manual IMR EX610 Portable Gas Detector Operation Manual IMR Environmental Equipment, Inc. 3634 Central Ave. St. Petersburg, FL 33711 Phone: 727-328-2818 email: info@imrusa.com Read this manual carefully before

More information

Transmitters/Sensors. OLCT Series

Transmitters/Sensors. OLCT Series Transmitters/Sensors Gas Monitoring Solutions OLCT 20-40-50-60 Series SIL2 based on EN 50402 (OLCT 60 based on EN 50271) FLP approved Intrinsically Safe (IS) Precalibrated block module local or remote

More information

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors Electrochemical DrägerSensor Sensors for Fixed Gas Detectors Fast response, high accuracy, great stability, long life. Electrochemical DrägerSensors offer all these benefits. You can use the robust and

More information

E1000 Portable gas detector

E1000 Portable gas detector E1000 Portable gas detector Operation manual Ver:HWWM161229CG Read this manual carefully before using the device Table of Contents SAFETY INFORMATION... - 1-1. BRIEF INTRODUCTION... - 3-2. MAIN FUNCTION

More information

Installation and Wiring 1.

Installation and Wiring 1. Installation and Wiring 1. Please read the Security Notifications in detail firstly. 2. The gas detector might install on wall or steel plate, please refer following drawing to make marking then drill

More information

Installation & User Manual

Installation & User Manual & INFRARED & CATALITIC DETECTORS Installation & User Manual ATEX IP65 Certificate nº FS82426 2013 DURAN ELECTRONICA S.L. - All rights reserved www.duranelectronica.com TABLE OF CONTENTS pages 1. DIREX.

More information

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

4P75 CiTipeL Combustible Gas Sensor Part Number: PM Product Datasheet 4P75 Document Purpose The purpose of this document is to present the performance specification of the 4P75 CiTipeL. This document should be used in conjunction with Operating Principles

More information

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction BST-MG08/09 Multi-gas Detecting Alarm Manual Instruction 1. Application: This product is designed to ensure safety for users who work in dangerous places. It s used for detecting CO, O2, H2S, CH4 simultaneously

More information

portable gas analyser

portable gas analyser www..com portable gas analyser Professional flue gas analyser that combines high quality of sample conditioning with great measurement accuracy. The device is contained in a compact soft casing. Analyser

More information

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control. Détecteur de gaz OLCT80 Detectors-Transmitters for Flammable, Toxic Gases and Oxygen Non-intrusive operation via intrinsically safe infrared remote control Disponible en version déportée, ADF ou de SI

More information

IMR IX176 Portable Gas Detector User Manual

IMR IX176 Portable Gas Detector User Manual IMR Portable Gas Detector User Manual Read this manual carefully before using this device. (727) 328-2818 / (800) RING-IMR Fax: (727) 328-2826 www.imrusa.com Ver. 1.0A4 CONTENTS SERVICE GUIDELINES... 3

More information

PRODUCT CATALOG 2016 PT. Victoria Globalindo Teknik PT. Victoria Agfasindo

PRODUCT CATALOG 2016 PT. Victoria Globalindo Teknik PT. Victoria Agfasindo PRODUCT CATALOG 2016 PT. Victoria Globalindo Teknik Jl. Pluit Karang Ayu Blok B1 Apartment Green Bay Pluit Tower E Lt. 3, Suite AM 14450, North Jakarta, Indonesia Telephone: +6289610416092 Website: www.vgt.co.id

More information

ALTAIR 5X Multigas Detector

ALTAIR 5X Multigas Detector ALTAIR 5X Multigas Detector With MSA XCell Sensor Technology IT S WHAT S INSIDE THAT COUNTS Now with advanced PID for VOC detection Because every life has a purpose... Save Time, Save Money, Save Lives

More information

SAFESITE Multi-Threat Detection System

SAFESITE Multi-Threat Detection System SAFESITE Multi-Threat Detection System The SAFESITE Multi-Threat Detection System simultaneously monitors and wirelessly communicates six potential threats: CWAs, VOCs, TICs, gamma radiation, combustible

More information

MODEL: Q8 SERIES NON-INTRUSIVE CALIBRATION GAS TRANSMITTER/SENSOR

MODEL: Q8 SERIES NON-INTRUSIVE CALIBRATION GAS TRANSMITTER/SENSOR MODEL: Q8 SERIES NON-INTRUSIVE CALIBRATION GAS TRANSMITTER/SENSOR INSTALLATION OPERATION AND MAINTENANCE MANUAL QUATROSENSE ENVIRONMENTAL LTD. 5935 OTTAWA STREET, PO BOX 749 (RICHMOND) OTTAWA, ONTARIO

More information

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof. DETECTION PERSONAL PROTECTION DIVING TECHNOLOGY SYSTEM TECHNOLOGY SERVICES Dräger X-am 7000 ST-2660-2003 Dräger X-am 7000 is the innovative solution for the simultaneous and continuous detection of up

More information

Choosing the best detection technologies for measuring combustible gas and VOC vapors

Choosing the best detection technologies for measuring combustible gas and VOC vapors Choosing the best detection technologies for measuring combustible gas and VOC vapors gas an oxygen sensor responds to is oxygen. Electrochemical sensors designed to measure a particular gas may not be

More information

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2

CH 4 C 2 H 2 C 3 H 8 CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2 PluraSens CH 4 C 2 H 2 C 3 H 8 CO CO 2 H 2 H 2 S HFC NH 3 NO 2 O 2 O 3 SO 2 VOC E2600 Family Gas Detectors E2610 Series Compact wall-mount housing providing optimal airflow Integrated sensor with long

More information

GAS DETECTION MANUFACTURED BY. Aerionics, Inc. Sioux Falls, SD Phone:

GAS DETECTION MANUFACTURED BY. Aerionics, Inc. Sioux Falls, SD Phone: CM-1 CO ppm MANUFACTURED BY Aerionics, Inc. Sioux Falls, SD Phone: 1-877-367-7891 Email: info@aerionicsinc.com www.macurco.com Detectors for use with Fire and Security Systems The Macurco CM-E1, GD-2B,

More information

GAS DETECTION SYSTEMS

GAS DETECTION SYSTEMS GAS DETECTION SYSTEMS GAS DETECTION SYSTEMS Contents Introduction 3 Introduction to Gas Detection Systems 3 Introduction to the Gas Sense System 3 Where to Install a Gas Detector 4 When to Test the Detector

More information

Meridian. Universal Gas Detector. Description. Features. Minimal drift High specificity Digital ID Broader toxic gas detection

Meridian. Universal Gas Detector. Description. Features. Minimal drift High specificity Digital ID Broader toxic gas detection 3M TM Meridian Description Designed with safety and reliability in mind, the Meridian universal gas detector is suitable for use in SIL-2 and SIL-3-rated systems under the IEC 61508 standards, certified

More information

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS TECHNICAL NOTE s for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS The DataFID and MicroFID II are portable flame ionization detectors designed to monitor volatile organic

More information

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex

Many different instruments Many different operating principles including: May sample many different gases & vapour From relatively simple to complex Part 2 Direct Reading Instrumentation Direct Reading Instruments Many different instruments Many different operating principles including: Electrochemical Photoionisation Flame ionisation Chemiluminescence

More information

Series 3000 XPIS. 2-wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres

Series 3000 XPIS. 2-wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres Series 3000 XPIS -wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres Series 3000 XPIS Reliable detection Proven electrochemical sensing technology Uses Surecell

More information

GAS ANALYSIS / DETECTION Gas Detector

GAS ANALYSIS / DETECTION Gas Detector Eikon - Single gas recyclable personal monitor GAS ANALYSIS / DETECTION Tough and rugged Eikon is the durable single gas fixed life personal monitor that really lasts the course. Loud & Clear Alarms Easy

More information