1 Relays for use in hazardous locations Class I, Division 2 and ATEX

2 Explosion protection in North America azardous (classified) locations, as defined in the National Electric Code (NEC), are locations where fire or explosion hazards may exist due to the presence of flammable gases, vapors, flammable liquids, combustible dusts, ignitable fibers or flying matter. Article 500 of the NEC divides all hazardous (classified) locations into Classes, Divisions and Groups. Phoenix Contact s hazardouslocation relays have been tested and approved for: Class I, Division 2; Groups A, B, C, D; and Class I, Zone 2 Class I: Areas in which flammable gases or vapors are or may be present in the air in quantities sufficient to produce explosive or ignitable mixtures Division 2: Environments that are not normally hazardous Groups A, B, C, D: Gas mixtures have been grouped on the basis of their characteristics: Group A Atmospheres containing acetylene Group B Atmospheres containing acrolein, butadiene, ethylene oxide, propylene oxide, hydrogen and fuel and combustible process gases containing more than 30 percent hydrogen by volume Group C Atmospheres containing ethyl ether and ethylene Group D Atmospheres containing acetone, ammonia, benzene, butane, cyclopropane, ethanol, gasoline, hexane, methane, methanol, naphtha and propane Class I, Zone 2 Nonsparking Equipment has no normally arcing parts or thermal effects capable of ignition Sparking with protected contacts Arcing contacts are in nonincendive circuits, or are inside a hermetically sealed container or sealed device Explosion protection in Europe The countries that make up the European economic area adopt directives as their national laws. The ATEX directive is the law of every country in the European community, and part of that law states that all products for use in explosive atmospheres must meet the directive. This means that all manufacturers of mechanical and electrical equipment intended for use in potentially explosive atmospheres that wish to place these products on the market within the European Union need to comply with the ATEX directive. Phoenix Contact s ATEX relays are dual rated for Class I, Division 2 and for ATEX. ATEXapproved parts are classified into Device Groups and Categories. Our ATEX relays are approved for Device Group II and Category 3G, for use in Zone 2 (gases). II (Device Group II) Areas with an explosive atmosphere, like chemical industries, mills (combustible gases and dusts) 3 (Category 3) Equipment that is intended for use in areas where an explosive atmosphere is unlikely to occur in normal operation and where operators must ensure a normal level of protection G Gas, suitable for atmospheres containing gas Ex Explosionproof electrical equipment II (Device Group) Surface installations C (Gas Group) ydrogen POENIX CONTACT

3 azardous location relays The industry has imposed stringent requirements on the reliability and safety of switching components in potentially explosive areas. In order to protect against explosion, all equipment that could be exposed to the flammable or combustible atmospheres in hazardous (classified) locations must be of a type suitable for installation in these areas. The classes and groups for which equipment has been certified are shown in the individual certifications under the respective categories and are marked on the equipment itself. Phoenix Contact s hazardouslocation relays our slim PLC Relay series have the required approvals for process control equipment. Our Class I, Division 2 (CID2) relays are UL/cUL listed for use in the Americas. Also available are dualrated ATEX relays: rated for both CID2 and ATEX approvals. Therefore, these relays are certified through UL/DEMKO and comply with the ATEX directive required for the European market. POENIX CONTACT

4 ATEX relays 2 PDT with power contact 1 PDT with power contact Notes: of housing: Polyamide PA nonreinforced, color: green. Separating plate PLCATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8PLC... or FBST A A Technical data Technical data Input data Switching level (with reference to U N ) Typ. input current at U N Typ. response time/switchon time at U N Typ. release time/switchoff time at U N Transmission frequency f limit Input circuit DC Input circuit AC/DC Output data Contact material Max. switching voltage Min. switching voltage Limiting continuous current Max. inrush current Min. switching current Output protection Voltage drop at max. limiting continuous current General data Test voltage input/output Ambient temperature (operation) Mechanical service life Standards/regulations Pollution degree/surge voltage category Connection data solid/stranded/awg Dimensions EMC note Conformance/approvals Conformance ATEX UL, USA UL, USA / Canada UL, Canada Description 1 signal ( ) 0 signal ( L ) [ma] [ms] [ms] [z] W//D PLC INTERFACE, with screw connection 1 12 V DC 2 24 V DC V AC (110 V DC) V AC PLC INTERFACE, with springcage connection surge protection AgNi 250 V AC/DC 5 V AC/DC (at 10 ma) 6 A 15 A (300 ms) 10 ma (at 5 V) 4 kv (50 z, 1 min.) 40 C to +70 C 3 x 10 7 cycles IEC 60664, EN 50178, IEC 62103, EN , EN /III mm/80 mm/94 mm CEcompliant DEMKO 03 ATEX U; II 3G Ex na nc IIC Gc ing data Input voltage U N 12 V DC 24 V DC 120 V AC (110 V DC) freewheeling diode AgSnO 250 V AC/DC 5 V (at 100 ma) 6 A on request 10 ma (at 12 V) 4 kv AC (50 z, 1 min.) 40 C to +60 C 2 x 10 7 cycles IEC 60664, EN 50178, IEC 62103, EN , EN /III CEcompliant DEMKO 11 ATEX U; II 3G Ex na nc IIC Gc ing data PLCRSC24DC/2121ATEX PLCRSC24DC/21 ATEX PLCRSC120UC/21 ATEX

5 Class I, Division 2 (CID2) relays 1 PDT with power contact Max. DC voltage output of 3 A Max. DC voltage output of 100 ma A2 11 A2 13+ A Technical data Technical data Technical data freewheeling diode freewheeling diode AgSnO 250 V AC/DC 12 V AC/DC 6 A 10 ma 33 V DC 3 V DC 3 A 15 ma (10 ms) Protection against polarity reversal, surge protection 200 mv 48 V DC 3 V DC 100 ma Protection against polarity reversal, surge protection 1 V 4 kv AC (50 z, 1 min.) 20 C to +60 C 2 x 10 7 cycles IEC 60664, EN 50178, IEC /III Class A product 2.5 kv (50 z, 1 min.) 20 C to +60 C IEC 60664, EN 50178, IEC /III Class A product 2.5 kv (50 z, 1 min.) 20 C to +60 C IEC 60664, EN 50178, IEC /III Class A product CEcompliant CEcompliant CEcompliant ing data ing data ing data PLCRSC12DC/21/C1D2 PLCRSC24DC/21/C1D2 PLCRSC120UC/21/C1D2 PLCRSC230UC/21/C1D PLCOSC24DC/ 24DC/ 2/C1D2 PLCOSC120UC/ 24DC/ 2/C1D PLCOSC24DC/ 48DC/100/C1D2 PLCOSC120UC/ 48DC/100/C1D PLCRSP12DC/21/C1D2 PLCRSP24DC/21/C1D2 PLCRSP120UC/21/C1D

6 Always uptodate, always available. Everything you ll need to know about our products, our solutions and our service is right here: Product range Cables and connectors Connectors Controllers and PLCs Electronic reversing contactors and motor controls Electronics housing Ethernet networks Fieldbus components and systems Functional safety MIs and industrial PCs I/O systems Industrial communication technology Industrial lighting Installation and mounting material Marking and labeling Measurement and control technology Modular terminal blocks Monitoring PCB terminal blocks and PCB connectors Powersupply units and UPS Protective devices Relay modules Sensor cables and connectors Software Surge protection devices System cabling for DCS and PLC Tools Wireless data communication USA POENIX CONTACT P.O. Box 4100 arrisburg, PA Phone: Technical Service: Fax: Website: Canada POENIX CONTACT Ltd Parkhill Drive Milton, Ontario L9T 5V7 Toll Free: Phone: Fax: L003468A: POENIX CONTACT

Fire Alarm System Accessories

Fire Alarm System Accessories UL, ULC Approved* Fire Alarm System Accessories Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer isolated barrier

More information

UL HAZARDOUS LOCATIONS SERVICES

UL HAZARDOUS LOCATIONS SERVICES UL HAZARDOUS LOCATIONS SERVICES The international preference in hazardous locations certification for over 100 years ul.com/hazloc Explosive Gas Atmospheres Class I Division S Includes flammable gases,

More information

Fire Alarm System Accessories

Fire Alarm System Accessories Approved by APPROVED Fire Alarm System Accessories FM Approved* Intrinsically Safe Devices Single and Dual Channel Isolated Barrier Modules Features Single or dual channel intrinsically safe, transformer

More information

VSD AND SS DRIVING ATEX MOTORS February 2014

VSD AND SS DRIVING ATEX MOTORS February 2014 VSD AND SS DRIVING ATEX MOTORS February 2014 1 Introduction to ATEX 2 ATEX motor designation 3 VSD Sample Solutions 4 SS descriptions Introduction to ATEX EU territory define the use of electrical equipment

More information

1. GENERAL TECHNICAL INFORMATION

1. GENERAL TECHNICAL INFORMATION 1. GENERAL TECHNICAL INFORMATION 1.1 EXPLOSIVE ATMOSPHERES: Every time that dangerous quantities and concentration of flammable gas, vapors mixture or dust clouds exists, risk of explosions may arise.

More information

Overview of Hazardous Locations as They Relate to Solenoid Valves

Overview of Hazardous Locations as They Relate to Solenoid Valves Overview of Hazardous Locations as They Relate to Solenoid Valves Defined: Hazardous Location - "where fire or explosion hazards may exist due to flammable gases or vapors, flammable liquids, combustible

More information

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt Airo Wireless Intrinsically Safe White Paper Written By: David Schmitt Intrinsically Safe Cell Phone/Smartphone/PDA Intrinsically Safe (IS) is a protection certification for safe operation with electronic

More information

SAFETY APPROVED FLASHLIGHTS: UNDERSTANDING THE REQUIREMENTS INTRODUCTION & OVERVIEW

SAFETY APPROVED FLASHLIGHTS: UNDERSTANDING THE REQUIREMENTS INTRODUCTION & OVERVIEW SAFETY APPROVED FLASHLIGHTS: UNDERSTANDING THE REQUIREMENTS INTRODUCTION & OVERVIEW Any flashlight that is intended to be used in a hazardous location must be tested and approved for that use because it

More information

S T R I T T & P R I E B E I N C.

S T R I T T & P R I E B E I N C. Equipment Enclosure Comparisons Type of Enclosure European - Area of use Designation Standard IEC - Area of use Designation Standard USA - Area of use Designation Standard Flameproof Enclosure An enclosure

More information

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC EUROPEAN ATEX DIRECTIVE > European Directive 2014/34/EU ATEX Directive 2014/34/EU is a "new approach" directive that applies to protective systems against explosions as well as all equipment used in or

More information

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS Hazardous Areas - EXPLOSIONPROOF SOLENOIDS SOME HISTORY The classification of hazardous areas into zones established the level of protection required for electrical equipment installed in explosive gas

More information

Hazardous area descriptions

Hazardous area descriptions Hazardous area descriptions National Electrical Code (NEC) 500 Traditional standards used in North America. Example: Class I, Div 1, Group B, C, D, T4 Permitted Class Permitted Division Permitted Group

More information

Guide for hazardous areas

Guide for hazardous areas Guide for hazardous areas 1 Hazardous areas definitions 2 Gas and dust s 3 Temperature classifications 4 Common flammable gases, vapours and dust types 5 Protection concepts ATEX and IECEx 6 Protection

More information

Explosion-protected actuator Page 259 of 292

Explosion-protected actuator Page 259 of 292 Explosion-protected actuator Page 259 of 292 9.5 Explosion-protected actuator 9.5.1. What is an explosion? A flammable substance and oxygen, in a certain mixture, must be available to set off an explosion.

More information

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The R. STAHL Technology Group Worldwide Success with Competence and Customer Support The entrepreneurial basis of the R. STAHL Technology Group follows a long tradition. The product range is aimed at specialised

More information

Explosion-proof Duct Heaters

Explosion-proof Duct Heaters Safety INDEECO explosion-proof ULTRA-SAFE and EP2 duct heaters are Factory Mutual (FM) and CSA Approved. The ULTRA-SAFE duct heater has the only standard product offering and features the industry s lowest

More information

INSTRUCTION & SERVICE MANUAL

INSTRUCTION & SERVICE MANUAL INSTRUCTION & SERVICE MANUAL D2xC1 ALARM HORN AND STROBE For Use In Hazardous Locations 3) Ratings and Markings 3.1 ATEX / IECEx certification The D2xC1 Alarm Horn and Strobe complies with the following

More information

Beamex. Calibration White Paper. Calibration in hazardous areas

Beamex. Calibration White Paper.   Calibration in hazardous areas Beamex Calibration White Paper info@beamex.com Calibration in hazardous areas This article discusses calibration in hazardous areas and what everyone needs to be aware of before entering into a hazardous

More information

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS For a print friendly page click here INTRODUCTION Hazardous areas are those in which there exists a risk of explosion

More information

ATEX Safety Switches. More than safety.

ATEX Safety Switches. More than safety. ATEX Safety Switches More than safety. AUDIN - 8, avenue de la malle - 5370 Saint Brice Courcelles Tel : 03.6.0.0. - Fax : 03.6.0.8.0 - Web : http: www.audin.fr - Email : info@audin.fr ATEX products from

More information

Beamex Calibration White Paper. Calibration in hazardous areas

Beamex Calibration White Paper.  Calibration in hazardous areas Beamex Calibration White Paper info@beamex.com Calibration in hazardous areas This article discusses calibration in hazardous areas and what everyone needs to be aware of before entering into a hazardous

More information

BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62.

BSF4-AH80. Flameproof Type Light Curtain Type 4. Globally-compliant flameproof structure. Ample protective height 1,595 mm 62. 637 PHOTO PHOTO Flameproof Type Curtain Type 4 General terms and conditions... F-7 Related Information Glossary of terms... P.1455~ Sensor selection guide... P.497~ General precautions... P.1458~ Conforming

More information

Hazardous Area Classifications and Protections

Hazardous Area Classifications and Protections Hazardous Area Classifications Product Bulletin Hazardous Area Classifications and Protections The intent of this document is to provide a broad overview of hazardous area classifications and the types

More information

Electron Microscopy Sciences

Electron Microscopy Sciences Electron Microscopy Sciences INSTRUCTIONAL MANUAL CAT. 72341-10 Explosion Proof Hot Plate Stirrer Model SF87325 P.O. Box 550 s1560 Industry Road s Hatfield PA 19440 1 Safety Symbols Used in this Instruction

More information

Selection guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global

Selection guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P panasonic.net/id/pidsx/global 597 Flameproof Type Light Curtain Type 4 General terms and conditions... F-3 Related Information guide...p.457~ SF-C13...P.663~ Glossary of terms... P.1549~ General precautions... P.1595 PHOTO PHOTO Certified

More information

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations INSTRUCTION MANUAL E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING

More information

Dräger PEX 3000 Flammable Gas Detection

Dräger PEX 3000 Flammable Gas Detection Dräger PEX 3000 Flammable Gas Detection The transmitter Dräger PEX 3000 detects flammable gases and vapors in concentrations below their Lower Explosion Limit Its DD-sensor provides a very long-term stable

More information

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate OPERATION MANUAL SERIES 873 UL Listed for Class I, Group C and D Hazardous Locations Model # Voltage Description SP87325 120 9.13 X 9.13 (23.2

More information

standards: standards:

standards: standards: INSTRUCTION MANUAL D2xB1LD2 LED Beacons For use in Hazardous Locations 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT DO NOT OPEN WHEN ENERGISED POTENTIAL ELECTROSTATIC CHARGING HAZARD

More information

Flameproof Type Light Curtain Type 4

Flameproof Type Light Curtain Type 4 545 PHOTO PHOTO Flameproof Type Curtain Type 4 Sensor selection guide...p.11~ / P.479~ General terms and conditions... P.1 SF4-AH... P.569 ~ Glossary of terms / General precautions... P.983 ~ / P.986 ~

More information

Specifying Temperature Sensors for Hazardous Areas

Specifying Temperature Sensors for Hazardous Areas Specifying Temperature Sensors for Hazardous Areas The manufacture of petroleum products, paint, and many chemicals can lead to the release of flammable gases. When these gases accumulate in enclosed areas,

More information

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations INSTRUCTION MANUAL D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations synchronization requirements of UL1971 & UL1638 / CAN/ULCS526. 2.2 NEC & CEC Class / Division Ratings for US / Canada

More information

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors Drive Technology \ Drive Automation \ System Integration \ Services *23511257_0817* Inquiry Forms for Explosion-Proof Gearmotors Edition 08/2017 23511257/EN SEW-EURODRIVE Driving the world Inquiry forms

More information

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE PUE HX5.EX explosion-proof hazardous area indicator ATEX APPROVAL PUE HX5.EX is a cutting-edge weighing indicator, designed to

More information

Explosion protection Marijan Gorše, dipl. ing.

Explosion protection Marijan Gorše, dipl. ing. Explosion protection Marijan Gorše, dipl. ing. 1/18 Flammable Gas Atmosphere We Can Control Them Explosion hazards mostly arise from flammable gases and vapours. Instead of avoiding their ignition by explosion

More information

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-8: ELECTRICAL EQUIPMENT ENCLOSURES AND HAZARDOUS LOCATIONS

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-8: ELECTRICAL EQUIPMENT ENCLOSURES AND HAZARDOUS LOCATIONS TSEWG TP-8: ELECTRICAL EQUIPMENT ENCLOSURES AND HAZARDOUS LOCATIONS ENCLOSURES. Select equipment enclosures to provide the following: To protect facility personnel from coming in contact with live parts.

More information

Hazardous Area Classification in Oil & Gas Industry. A Fire Prevention Tool

Hazardous Area Classification in Oil & Gas Industry. A Fire Prevention Tool Hazardous Area Classification in Oil & Gas Industry A Fire Prevention Tool SFPE ENGINEERING TECHNOLOGY CONFERENCE Oct 4, 2010 New Orleans, LA 1 Overview Oil and gas plants handle flammable materials 2

More information

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here. A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here Introduction Potentially Explosive Atmospheres exist where there is a risk

More information

CLASS I LOCATIONS ZONE CLASSIFICATION

CLASS I LOCATIONS ZONE CLASSIFICATION HAZARDOUS (CLASSIFIED) LOCATIONS Hazardous locations are those locations where the risk of a fire or explosion may exist due to the presence of flammable gases or vapors, flammable liquids, combustible

More information

Understanding Hazardous Locations Concepts

Understanding Hazardous Locations Concepts Gas Well Deliquification Workshop Sheraton Hotel, February 23 26, 2014 Understanding Hazardous Locations Concepts Mark Scantlebury, P. Eng., BASc President and CEO Extreme Telematics Corp. Disclaimer The

More information

Introduction to Hazardous Electrical Location Classifications

Introduction to Hazardous Electrical Location Classifications Introduction to Hazardous Electrical Location Classifications Introduction In North America the target audience for this white paper and the electrical code classification ratings for various types of

More information

Manual. WAGO-I/O-SYSTEM 750 Use in Hazardous Environments 750-xxx Definition of Terms, Marking and Installation Regulations. Version 1.0.

Manual. WAGO-I/O-SYSTEM 750 Use in Hazardous Environments 750-xxx Definition of Terms, Marking and Installation Regulations. Version 1.0. WAGO-I/O-SYSTEM 750 Use in Hazardous Environments 750-xxx Definition of Terms, Marking and Installation Regulations 2 General WAGO-I/O-SYSTEM 750 General 2010 by WAGO Kontakttechnik GmbH & Co. KG All rights

More information

HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY

HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY Cell Phones Smartphones PDA integrating people, products and processes Intrinsically Safe Cell Phone/Smartphone/PDA Intrinsically Safe (IS) is a protection

More information

Switches compliant with ATEX directive

Switches compliant with ATEX directive Switches compliant with ATEX directive General Catalogue - Technical concepts page Position switches FD / FL series page 9 / Category Zone EPL Approvals 2G Gb Mb II 2G Ex ia IIC T6 Gb I Ex ia I Mb Product

More information

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals Selecting a Safe Tank Gauging Product Understanding Hazardous Area Definitions for Equipment Approvals Hazardous Area Approvals A Worldwide Requirement There are many environmental considerations within

More information

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES Limassol 20 th August, 2015 RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES This document is intended to provide clarification on the use of FirePro Condensed Aerosol Generators in Potential Explosive

More information

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems Products Solutions Services CT287 Hazardous Area Classifications and Protection Systems Slide 1 Topics covered Types of Hazardous Area classifications with focus on North America Types of hazardous protection

More information

Competence for Safety. ATEX Category 3 Description. Example of a zone division for combustible fluids (gases) and combustible dust

Competence for Safety. ATEX Category 3 Description. Example of a zone division for combustible fluids (gases) and combustible dust Competence for Safety Within the scope of the creation of the explosion protection document (mandatory for the operator according to ATEX 137), production locations must be divided into zones depending

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116279 (LR 025993_0_000) Issued to: General Monitors, Incorporated 26776 Simpatica Circle Lake Forest, California 92630 USA Attention: Larry Vlagea The

More information

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions Because every life has a purpose PrimaX IR Gas Transmitter Every feature of the SIL 2 engineered PrimaX IR Gas Transmitter

More information

APPLICATION DATA SHEET

APPLICATION DATA SHEET APPLICATION DATA SHEET S p e c i f i c a t i o n WWW.-..UK Control Systems Transmitters Sensors Accessories TOCSIN 700 D e t e c t o r C o n t r o l P a n e l Wall mounting 24V DC or 110/230vAC operation

More information

Dräger Polytron SE Ex Fixed Gas Detector

Dräger Polytron SE Ex Fixed Gas Detector Dräger Polytron SE Ex Fixed Gas Detector The Dräger Polytron SE Ex... DD sensing heads are gas detectors for the continuous monitoring of flammable gases and vapors in the ambient air. The measurement

More information

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches A Selection Guide Introduction There are many considerations when selecting a switch to be used in hazardous areas. In

More information

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres C E R T I F I E D DANISH TECHNOLOGICAL INSTITUTE DANISH TECHNOLOGICAL INSTITUTE The Danish Technological Institute is a self-owned and not-f-profit institution. We develop, apply and disseminate research- and technologically-based knowledge f the Danish

More information

Certificate of Compliance

Certificate of Compliance FF0 001 Certificate of Compliance Certificate: 70116284 (LR 064969_0_00) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296

More information

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres

ATEX - GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres Quick Introduction to: DANISH TECHNOLOGICAL INSTITUTE The Danish Technological Institute is a self-owned and not-fprofit institution. We develop, apply and disseminate research- and technologically-based

More information

Implementation of ATEX Guidelines

Implementation of ATEX Guidelines Implementation of ATEX Guidelines Temperature and Climatic Test Chambers for Usage under Conditions Carrying a Risk of Fire and Explosion What are ATEX guidelines? Introduction Duties of the system user...

More information

Notice of Proprietary Rights

Notice of Proprietary Rights Doc #: FOI-DC-AP-14001-B Application Manual Fiber Optic Switch (FiberSwitch ) Model: FOS-01 Fiber Optic Interface (FOI) Model: FOI-01-221 SIGMA RESEARCH Inc. 259 Edgeley Blvd, Unit #2 Vaughan, Ontario,

More information

Combustible Gas Leak Detector Instruction Manual

Combustible Gas Leak Detector Instruction Manual 719 Combustible Gas Leak Detector Instruction Manual TABLE OF CONTENTS A. INTRODUCTION 1. Congratulations...3 2. Product Description...3 B. SAFETY CONSIDERATIONS...4 C. TECHNICAL DATA 1. Features and Benefits...5

More information

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases DESCRIPTION Gas measuring and monitoring controller based on stateof-the-art microtechnology with integrated sensor for continuous monitoring

More information

ATEX, NOMENCLATURE AND CODING

ATEX, NOMENCLATURE AND CODING Technical Notes ATEX, NOMENCLATURE AND CODING The intent of this technical note is approach to the user to the ATEX normative. For this we will begin defining, what is an explosive atmosphere, what are

More information

Process Instrumentation. Product Guide. Registered Quality System to ISO 9001

Process Instrumentation. Product Guide. Registered Quality System to ISO 9001 Process Instrumentation Product Guide Registered Quality System to ISO 9001 SORis committed to and understands the demanding requirements of the process industry. We design, develop and manufacture the

More information

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas Intrinsic Safety Intrinsically Safe Solutions Accurate Weighing in Hazardous Areas Accidents in hazardous areas can have dramatic consequences for businesses in terms of both human life and profit. Intrinsically

More information

Guide to Hazardous Location Approvals:

Guide to Hazardous Location Approvals: Selection Guide Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches Introduction There are many considerations when selecting a switch to be used in hazardous areas. In addition

More information

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white . TECHNICAL DATA LIGHT FITTING REFLECTOR Polycarbonate tube of 4 mm. thickness Laquered steel painted white END CAPS Aluminium 2030 (polyester paint RAL 7047) POWER SOURCE LAMP TYPE 220-240V, 50/60Hz T8

More information

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres]

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres] II 2G EEx ia d ATEX 100 D MT IIC T6 99 ATEX G 001 x Series [ Versatility in Explosive Atmospheres] [ The flexible solution for all your needs] After accidents with hazardous material the will provide reliable

More information

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0. Selection of Explosion Protected Equipment for Hazardous Locations Compiled by: Pieter Coetzee ZONE 2 ZONE 0 ZONE 1 Be safe be Ex Contents Introduction Occupational Health and Safety Act. (Act 85 of 1993)

More information

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules Engineering Guideline pac-carriers Type 9195 SIEMENS ET-200M Fail-safe signal modules pac-carrier Type 9195 2 Engineering Guideline/SIEMENS 19.05.2015 pac-carrier Type 9195 Integration of conventional

More information

Engineering Guideline. pac- Carriers Type Universal

Engineering Guideline. pac- Carriers Type Universal Engineering Guideline pac- Carriers Type 9195 Universal Integration of conventional process automation interfaces pac- Carrier The pac- Carrier reflects the intention of R. STAHL to provide state-of-the-art

More information

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6 Digital Gas Transmitters with Auxiliary s & Control Specifications subject to change without notice. USA 181011 Page 1 of 5 DESCRIPTION Digital RS-485 communicating, addressable toxic and combustible gas

More information

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger PIR 3000 Detection of flammable gases and vapours Dräger PIR 3000 Detection of flammable gases and vapours The Dräger PIR 3000 is an explosion proof infrared gas detector for continuous monitoring of combustible gases and vapors Based on a stainless steel

More information

Model C Combustible Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

Model C Combustible Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park Model C12-17 Combustible Gas Transmitter Home Office European Office Analytical Technology, Inc. ATI (UK) Limited 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park Collegeville, PA 19426 Delph New

More information

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring] ULTIMA XIR ULTIMA X 3 ULTIMA XE ULTIMA X Series [ State-of-the-Art Gas Monitoring] ULTIMA X Gas Monitors [ Providing a unique Range of Capabilities] ULTIMA X are state-of-the-art gas monitors for continuous

More information

Combustible Gas Leak Detector Instruction Manual

Combustible Gas Leak Detector Instruction Manual 721 Combustible Gas Leak Detector Instruction Manual TABLE OF CONTENTS A. INTRODUCTION 1. Congratulations...3 2. Product Description...3 B. SAFETY CONSIDERATIONS...4 C. TECHNICAL DATA 1. Features and Benefits...5

More information

[ TECHNOLOGY ] and does this definition affect a burner.

[ TECHNOLOGY ] and does this definition affect a burner. [ TECHNOLOGY ] JBD-11,500-G type burner for natural gas ATEX, EExd Zone 2. For combined cycle power plant in Riga Latvia. Aitor Fernández Project Engineer Automation Department Head afernandez@emcombustion.es

More information

Technical data sheet TDS0034

Technical data sheet TDS0034 Technical data sheet TDS0034 PREMIER HYDROCARBON INFRARED SENSOR CERTIFIED VERSIONS TYPES MSH-P-HC and MSHia-P-HC Patent Numbers Great Britain GB 2 401 432 & GB 2 403 291 Europe EP 1544603 & EP 1818667-Pending

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) BExBG15E and BExBG10E Flameproof / Increased Safety Xenon Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG15E and BExBG10E beacons are flameproof

More information

ESD3000 ESD200 Combustible / Toxic Gas Detector

ESD3000 ESD200 Combustible / Toxic Gas Detector ESD3000 ESD200 Combustible / Toxic Gas Detector Combustible and toxic gas leakage inspection instrument in industrial application Ex-proof certificate Exd ⅡC T6 Gb/Ex d ib ⅡC T6 Gb Dust Ex-proof certificate

More information

99 Washington Street Melrose, MA Phone Toll Free Visit us at

99 Washington Street Melrose, MA Phone Toll Free Visit us at 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Combustible Gas Leak Detector Instruction and Operation Manual Page 2 Detector

More information

PREMIER PLATINUM INFRARED TRIPLE RANGE HYDROCARBON SENSOR Exd Certified versions *** Available in EN50271 / SIL1 Certified versions ***

PREMIER PLATINUM INFRARED TRIPLE RANGE HYDROCARBON SENSOR Exd Certified versions *** Available in EN50271 / SIL1 Certified versions *** Technical data sheet TDS0118 PREMIER PLATINUM INFRARED TRIPLE RANGE HYDROCARBON SENSOR Exd Certified versions *** Available in EN50271 / SIL1 Certified versions *** SIL1 Non - SIL MSH-PS/HC MSHia-PS/HC

More information

ATEX Explained A brief Introduction

ATEX Explained A brief Introduction The Trusted Source for Secure Identity Solutions ATEX Explained A brief Introduction January 19, 2016 ATEX Zones Zones 1 (gas) or 21 (dust) (area in which under normal operation a potentially explosive

More information

ATEX, NOMENCLATURE AND CODING

ATEX, NOMENCLATURE AND CODING ATEX, NOMENCLATURE AND CODING The intent of this technical note is approach to the user to the ATEX normative. For this we will begin defining, what is an explosive atmosphere, what are ATEX, as well as

More information

For technical questions, contact: Grace Engineered Products Inc./ 5001 Tremont Ave, Davenport, IA /

For technical questions, contact: Grace Engineered Products Inc./ 5001 Tremont Ave, Davenport, IA / For technical questions, contact: Grace Engineered Products Inc./ 5001 Tremont Ave, Davenport, IA 52807 / 800.280.9517 563.386.9639 (Fax) INSTALLATION AND OPERATING INSTRUCTIONS R-3W2 UL APPROVED FOR:

More information

ESD500. ESD500 Combustible / Toxic Gas Detector

ESD500. ESD500 Combustible / Toxic Gas Detector ESD500 ESD500 Combustible / Toxic Gas Detector Combustible and toxic gas leakage inspection instrument in industrial application Ex-proof certificate Exd ⅡC T6 Gb/Ex d ib ⅡC T6 Gb Dust Ex-proof certificate

More information

Dual certification! Air handling units for potentially explosive atmospheres

Dual certification! Air handling units for potentially explosive atmospheres Dual certification! Air handling units for potentially explosive atmospheres X-CUBE Ex A certified safety product The air handling unit with dual ATEX certification ATEX directive 2014/34/EU applies to

More information

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates Note: While this material was originally prepared for presentation in February 1999, it has been updated to reflect the evolving technical requirements now applicable as of April 2003. UL Topic III Converting

More information

Dräger Polytron Pulsar 2 Open Path Gas Detector

Dräger Polytron Pulsar 2 Open Path Gas Detector Dräger Polytron Pulsar 2 Open Path Gas Detector The Dräger Polytron Pulsar 2 represents the latest infrared technology in open path gas detection. Equipped with all the same functions as the standard Dräger

More information

Certification Supplement Manual

Certification Supplement Manual PROCESS ANALYSERS SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 2 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EC DECLARATION OF CONFORMITY

More information

CLASSIFICATION COMPARATOR

CLASSIFICATION COMPARATOR CLASSIFICATION COMPARATOR THE IEC/NEC COMPARATOR World standards for the classification of hazardous areas are moving toward harmonization. The 999 U.S. National Electric Code (NEC ) and the 998 Canadian

More information

Page 1 Copyright by the Fieldbus Foundation All rights reserved.

Page 1 Copyright by the Fieldbus Foundation All rights reserved. Page 1 Copyright by the Fieldbus Foundation 1996-2004.. FOUNDATION Fieldbus Application Guide 31,25 kbit/s Intrinsically Safe Systems AG-163 Revision 2.0 This application guide has been prepared to aid

More information

MICROpeL 75 Combustible Gas Sensor Part Number: PM

MICROpeL 75 Combustible Gas Sensor Part Number: PM MICROpeL 75 Combustible Gas Sensor Part Number: PM759-000 Key Features & Benefits: ATEX, UL and CSA Approvals Withstands EN/IEC 60079-0 impact test Enhanced H 2 S and silicone poison resistance Reduced

More information

LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions ***

LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions *** Technical data sheet TDS0149 LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions *** SIL1 MSH2-LS/HC/CO2 MSH2ia-LS/HC/CO2

More information

PREMIER PLATINUM INFRARED GAS SENSOR

PREMIER PLATINUM INFRARED GAS SENSOR PREMIER PLATINUM INFRARED GAS SENSOR LOW POWER VERSION DUAL HYDROCARBONS AND CARBON DIOXIDE SENSOR Exd Certified VERSIONS *** Available in EN50271 / SIL1 Certified versions *** Technical data sheet TDS0150

More information

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExBG05D-SIL is a flameproof beacon which is certified

More information

Certification Supplement Manual

Certification Supplement Manual SERVOTOUGH FluegasExact (2700) Gas Analyser Certification Supplement Manual Part Number: 02700008D Revision: 5 Language: UK English Blank CONTENTS 1 INTRODUCTION 2 EU DECLARATION OF CONFORMITY 3 EUROPEAN

More information

Model D12-IR. Digital Gas Transmitter...

Model D12-IR. Digital Gas Transmitter... Model D12-IR Digital Gas Transmitter... ATI s Series D12 gas transmitter line now includes a versatile Infrared system that can be configured for LEL or select toxic gases. The D12-IR utilizes a compact

More information

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20 Applications Chemical, Petrochemical

More information

Gas detector INSTRUCTION MANUAL THE BELGIAN PIONEER IN GAS DETECTION

Gas detector INSTRUCTION MANUAL THE BELGIAN PIONEER IN GAS DETECTION Gas detector INSTRUCTION MANUAL THE BELGIAN PIONEER IN GAS DETECTION Copyright 2016 by DALEMANS s.a. Revision V1R2 07/2016 Any reproduction, whether partial or entire, made of this document, by whatever

More information

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories Hazardous Locations: Understanding the Basics of Global Compliance Requirements Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories DISCLAIMER/ TERMS OF USE: THE INFORMATION

More information

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC Quick Introduction to TÛV Denmark TÜV Denmark - is a part of the TÜV NORD Group a global Organisation f Certification and Inspection of: Quality Management Systems, Products, Processes and Qualification

More information